View Bid Results For Dynamic Testing Machine Tenders

We found 264 Bid Results related to dynamic testing machine tenders. You can find Contractor details who won dynamic testing machine tenders along with contract details in Bid awards announcements section.

Filters
Stage
183
65
16
Tender Publishing Platform
44
220
State / UT
32
37
37
35
27
18
15
8
8
7
7
7
5
5
4
4
4
4
4
3
3
3
3
3
2
2
2
2
1
1
1
1
1
Contract Value
92
43
76
50
Publish Date
1
0
0
0
0
Sector
25
74
48
28
24
17
14
7
7
7
7
5
4
4
3
3
2
2
1
1
1
1
1
1
1
1
Ownership
7
130
50
39
36
7
1
1
Within keyword
Active filters:
Showing 1–6 of 264 tenders matching your filters
1.
Agriculture #11475879 Technical Bid
Tender For Motor Rewinding Work- 1 Electric Motor Rewinding Insulation Class- B0.5 Hp, 720, 960, 1440, 2900 Rpm Stator 2 0.75 Hp, 720, 960, 1440, 2900 Rpm Stator 3 1.00 Hp 720, 960, 1440,2900 Rpm Stator 4 2.00 Hp 720, 960, 1440,2900 Rpm Stator 5 3.00 Hp 720, 960, 1440,2900 Rpm Stator 6 5.00 Hp 720, 960, 1440,2900 Rpm Stator 7 7.5 Hp 720, 960, 1440,2900 Rpm Stator 8 10 Hp 720, 960, 1440,2900 Rpm Stator 9 11.5 Hp 720, 960, 1440, 2900 Rpm Stator 10 12.5 Hp 720, 960, 1440, 2900 Rpm Stator 11 15.00 Hp 720, 960, 1440, 2900 Rpm Stator 12 20 Hp To 120 Hp, 720, 960, 1440, 2900 Rpm Stator 13 Rotor 14 Rewinding Of Crane Duty Motor 15 Hp, 960 Rpm, Insulation Class- H Rotor 15 Stator 16 25 Hp, 960 Rpm, Insulation Class- H Rotor 17 Stator 18 Slipring Motor75 Hp, 1440 Rpm, Squral Cage Rotor Of Alluminium Binding Converted Into Copper Strip Binding And Dynamic Balancing With Certificate. 19 120 Hp To 250 Hp, 960,1440 Rpm Strip Binding Rotor 20 Stator 21 250 Hp, 585 Rpm, Strip Binding Rotor 22 Stator 23 265 Hp, 960 Rpm, Strip Binding Rotor 24 Stator 25 400 Hp, 720 Rpm, Strip Binding Rotor 26 Stator 27 Rewinding Of Cane Unloader Motor S-5 Duty 415 Volt15 Hp, 965 Rpm , 900 Starts/Stop Per Hour Rotor 28 Stator 29 25 Hp, 965 Rpm , 900 Starts/Stop Per Hour Rotor 30 Stator 31 Three Speed Motor Insulation Class - Fcentrifugal Motor 110 Kw Ac 1St Speed Upto 200 Rpm 32 2Nd & 3Rd Speed Upto 450 Rpm & 960 Rpm 33 Dc-Motor D-412 Kcp Centrifugal Machine 167 Kv, 1250 Rpm Rotor 34 Stator 35 Repair Of Core Assembly For 3 Speed Motor Of Centrifugal Machine 36 Buffing & Policing Of Rotor Commutator Of Dc Motor For D-412 Centrifugal Machine 37 Welding Machine Spares Rewinding Primary Coil 38 Secondary Coil 39 Choke Coil 40 D.C.Welding Machine Rectifier 230/24 Volt, 600 Amp. 41 Rewinding And Repairing Of Electronic Welding Machine 3 Phase 400 Amp. 42 D.G.Set Spares Rewinding166 Kva Alternator Of Dg Set 1500 Rpm, 50Hz, Pole Of Rotor 4 Nos. Complete Rewinding H Class Enamelled Copper Strip With Material And Labour And Dynamic Balancing With Test Certificate Rotor 43 Stator 44 320 Kva Alternator Of Dg Set 1500 Rpm Rotor 45 Stator 46 166 Kva Alternator Set Excitation System (Booster) 47 320 Kva Alternator Excitor Rotor 48 320 Kva Alternator Excitor Filed Coil 49 Rewinding And Repair Of Submersible Pump Motor 15 Hp 50 25 Hp 51 Complete Rewinding Of 1875 Kva Excitor Rotor (Jyoti Make) Of 1500 Kw Alternator With Satisfactory Testing & Trial On Load. 52 Other Rewinding Workbreak Thruster Mootor 53 Cooler Fan Single Speed / Three Speed 54 Exhaust Fan Single Phase / Three Speed 55 Rewinding Of Celling Fan 56 Brass Holder For Turbine Excitor 57 Copper Carbon Brush For Turbine Excitor 58 Repairing Of D.C. Excitor (Jyoti Make) 15 Kw With Packing & Cutting Of Commutator & Re-Soldering Of Lug Etc. Complete 59 Charges For Supply Of Diode Fixing Plate Alluminium For 1875 Kva Turbine Alternator
Contract Date: Ref. Documents Contract Value : Ref. Document
Cooperative No of Bidders 3
Uttarakhand View Result →
2.
Housing Urban and Rular Development #11319892 AOC
Quotation for NON CSR Electrical Item for the work supply installation testing and commissioning of Electrification at the Mahalaxmi Temple, Kolhapur,Dist.Kolhapur- 1 Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (4 m poles) 2 Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for DG Set). 3 SITC of ESE type Lightning Arrestor Air Terminal as per standard NFC 17-102, Level IV with protection radius 51 mtr @ mounting height 5 meter.LA should be have CPRI test cerficate and should have test cerficate as per NFC 17-102 of suitable europian authority. 4 SITC of 3 meter height Mounting structure MAST (FRP/G.I.), along with supporting guy rope, base plate, mounting structure, required nut bolts etc. 5 SITC of Strike Recorder with weather proof Enclousure. It should be standalone type with no external power source requirement. 6 SITC of Test Link 7 SITC of Pipe in Pipe type GI maintanance free earthing - 80/38 (3.0 Mtr.s) with all other loose acessories and earthing pit chamber and cover. 8 SITC of single core 35 Sq. MM. Insulated Alm. Armoured Cable along with all installation accessories like clamp etc. (Optional) from LA to Earth Pit. Manufacturer to specify Copper/Aluminium). 9 Supplying, fixing and commissioning of MLTP including: Incoming - 200A MCCB 25 KA-2 nos, 200A ATS 4P - 1 Nos, Bus 250A Aluminium Outgoing : 63A 4P MCB - 5 Nos, 40A 4P MCB- 10 Nos, 125A 4P MCCB - 1 Nos, 160A SP MCCB - 1 Nos with floor mount stand 10 Supplying, fixing and commissioning of LTFP with 200 AMPS MCCB Incomer 8 Nos. Outgoing with 40 AMPS FPMCB 11 Providing & erecting 4 Pole MCCB, 415 V, 125A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 12 Providing & erecting 4 Pole MCCB, 415 V, 160A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 13 Providing & erecting hot dipped galvanised Raceway with cover manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 50 mm height complete with necessary coupler plates & hardware. 14 Providing & erecting hot dipped galvanised Raceway with cover manufactured from 16 SWG (1.6 mm thick) GI sheet of 100 mm width & 50 mm height complete with necessary coupler plates & hardware. 15 Providing & erecting hot dipped galvanised junction box manufactured from 18 SWG (1.2 mm thick) GI sheet of 200 mm x 200 mm complete with necessary cover plates & hardware. 16 Providing & erecting hot dipped galvanised junction box manufactured from 18 SWG (1.2 mm thick) GI sheet of 300 mm x 300 mm complete with necessary cover plates & hardware. 17 Supply and Installation of 5MP PoE IP Bullet Camera with automatic varifocal lens from 3.3 to 10 mm lens and 30 meter inbuilt IR, Dual Streams with configurable bit rate, GOP and frame rate, Edge based Video Analytics- object classification (Human/Vehicle), object in field, line crossing, enter field, leave field, loitering, follow route, objects stopping or starting to move, counting, occupancy, condition change, similarity search, 16 number of analytics/rules can be configured simulaneously. The video analytics software can detect up to 64 objects per frame in real time. support memory card up to 2TB capacity with health monitoring for early service indication. The recording in local storage should also be AES encrypted, support ONVIF S,G,T,M with MQTT event forwarding, onboard data security by using TPM (Trusted Platform Module) and PKI, supports TLS 1.3, Secure boot, Signed Firmware, software sealing to notify of device configuration changes, Embedded Login Firewall to minimize DDOS Attack, X.509 v3 digital certificates with SHA516 signature hash, audit logs, Unsecure ports like HTTP and RTSP are disabled by default, uses RTSPS/SRTP for video streaming, UL 2900-2-3 Level 2 cybersecurity certified, Camera should have UL, EN, CE, FCC, NDAA, with IP 66 and IK10 impact protection 18 Supply and Installation of 5MP Outdoor Dome camera with 1/2.9‑inch CMOS, Effective pixels 3072 (H) x 1944 (V), 30fps, Sensitivity – (3100K, reflectivity 89%, 1/25, F1.3, 30IRE)Color 0.24 lx Mono 0.03 lx With IR 0.0 lx, 120 dB Dynamic range, Electronic Day/Night, Automatic Electronic Shutter (AES), H.265, H.264 MP (Main Profile); M-JPEG Video compression, White balance, Backlight Compensation, Privacy Mask,Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Audio detection (if microphone used), 3 to 10 mm Automatic Varifocal (AVF) lens, MicroSD card slot for edge recording, Motion, tamper and audio detection(if microphone used), FTP, IR range upto 30mtrs Dropbox and e-mail applications, 3 axis adjustment, ONVIF Profile S & G & T, PoE, IP66 and NEMA 4X, IK10, CE, FCC , UL certified. SD card support up to 2TB. 19 Supply and Installation of 5MP Indoor Dome camera with 1/2.9‑inch CMOS, Effective pixels 3072 (H) x 1944 (V), 30fps, Sensitivity – (3100K, reflectivity 89%, 1/25, F1.3, 30IRE) Color 0.24 lx Mono 0.03 lx With IR 0.0 lx, 120 dB Dynamic range, Electronic Day/Night, Automatic Electronic Shutter (AES), H.265, H.264 MP (Main Profile); M-JPEG Video compression, White balance, Backlight Compensation, Privacy Mask,Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Audio detection (if microphone used), 3 to 10 mm Automatic Varifocal (AVF) lens, MicroSD card slot for edge recording, Motion, tamper and audio detection(if microphone used), FTP, IR range upto 30mtrs Dropbox and e-mail applications, 3 axis adjustment, ONVIF Profile S & G & T, PoE, CE, FCC , UL certified. SD card support up to 2TB. 20 Supply and Installation of 12MP IR Panoramic camera with 1/2.3‑inch CMOS, 360° lens, Effective Pixels 3008 x 3008 (9 MP), 1 to 25 [30] fps, Sensitivity @30IRE: 0.15lux(color), 0.048lux(mono); 0 lux with IR; 20m IR; 120 dB WDR, Video compression H.264 (MP)/ H.265 (MP); M- JPEG, Electronic Day/Night, White Balance, Automatic Electronic Shutter, Backlight compensation, Intelligent Dynamic Noise Reduction (iDNR), Privacy Masking, Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Speed, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Camera Trainer (machine learning to train user specified objects), Built-in microphone(Integrated array with 3 digital MEMS audio sensors), Signal-to-Noise Ratio, Full-duplex / half duplex Audio Streaming, Memory card slot, 10/100 Base-T, ONVIF Profile S,G, M & T, clientside/cameraedge dewarping,IP66, NEMA 4X, IK10, PoE, CE,UL, FCC. 21 Supply and Installation of all-in-one recording, viewing and management solution for network surveillance systems for up to 256 channels, Pre-installed, pre-configured IP storage solution, with RAID-5/RAID-6 protected, Dedicated storage operating system delivers robust , secure operation, Hot-swappable hard drives, Advanced user and alarm management,Intel® Core™ i7-12700E (25 MB Intel® Smart Cache 2.10 GHz) Processor,16 GB DDR5,ECC UDIMM memory installed, 2U rack mount, 12 Trays: 3.5- inch SATA 3; max 18TB per HDD slot maximum supported, 12Gb/s SAS RAID Card, 4 USB ports; Intel onboard graphics (Intel® UHD Graphics 770),Microsoft Windows Server IoT 2022 for storage standard,UL, CE Certified. 2 x RJ45 Gigabit Ethernet LAN ports (teamed); 1 IPMI BMC port. Operating temperature (°C) 0°-40°C; Operating relative humidity, noncondensing (%) 8 - 90%. Video Managment software In-built (Server-client architecture) with Live viewing of multiple cameras, Local recording and snapshots, PTZ control and digital zoom, Playback and export from storage, Motion and forensic search, Multi-screen grid selection , Sequencing selection, favorite view design.Dual authorization login,e Map support,ONVIF profile S,T complied,User management,Alarm management,SQL based database,LDAP support.Support of camera edge based analytics/server based analytics alarm triggering. Certifications UL,CB,CE,FCC,NDAA,BIS 22 Supplying & erecting 55 professional LED display with 1920 *1080 ( Full HD) Display, suitable for 32/64 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In,Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON 23 Supply and Installation of Client Workstation with 21 Inch Monitor 24 RE-2AS Supply of EN 54-16 certified and EN 60849 standards, public address and voice alarm system that ensures a fast, safe and controlled emergency evacuation. It should have 2 class D 500W amplifiers, one shall be for the feild output with two configurations for 100V/70V lines and another one is as standby backup, 6 zones, 3 audio inputs, 6x6 audio matrix,Digital Signal Processing Based Voice Alarm Controller and LCD display 2 rows x 16 characters with 3 inputs. It should have the provition for battery installation with proper rigit & safe mounting option. It shall be suitable for both Wall or Rack mounting provision and have following features:- 1. Support Up to 8 MPS-8Z multizone micropohones or VAP-1 panels connected with CAT5 UTP cable 2. Digital Amplifier (inbuilt) 2X500 watts and 6 zones,Backup amplifier included . 3. 4 pre-amp outputs for external PAamplifiers connection. 4. 10 minutes storage for pre-recorded messag. 5. USB connectivity. 6. Password protection, 7. Overriding Facility for Emergency Condition. 8. Have In-Built or attached MIC. 9. Work on 100 - 240V~ 50/60Hz and standby battery 1x 12VDC. 10.FireAlarm Control Panel integration. 11. Interface MODBUS RTU RS 485 Half duplex Supply of EN 54-16 certified and EN 60849 standards, public address and voice alarm system that ensures a fast, safe and controlled emergency evacuation. It should have 2 class D 500W amplifiers, one shall be for the feild output with two configurations for 100V/70V lines and another one is as standby backup, 6 zones, 3 audio inputs, 6x6 audio matrix,Digital Signal Processing Based Voice Alarm Controller and LCD display 2 rows x 16 characters with 3 inputs. It should have the provition for battery installation with proper rigit & safe mounting option. It shall be suitable for both Wall or Rack mounting provision and have following features:- 1. Support Up to 8 MPS-8Z multizone micropohones or VAP-1 panels connected with CAT5 UTP cable 2. Digital Amplifier (inbuilt) 2X500 watts and 6 zones,Backup amplifier included . 3. 4 pre-amp outputs for external PAamplifiers connection. 4. 10 minutes storage for pre-recorded messag. 5. USB connectivity. 6. Password protection, 7. Overriding Facility for Emergency Condition. 8. Have In-Built or attached MIC. 9. Work on 100 - 240V~ 50/60Hz and standby battery 1x 12VDC. 10.FireAlarm Control Panel integration. 11. Interface MODBUS RTU RS 485 Half duplex 25 RE-2AS BC Supply of the Battery update and activation card EN54-4 certified for RE-2AS. Once activated, the card becomes a key for the charger to work permanently.Package dimensions (W x H x D) : 190 x 20 x 140 mm . Supply of the Battery update and activation card EN54-4 certified for RE-2AS. Once activated, the card becomes a key for the charger to work permanently.Package dimensions (W x Hx D) : 190 x 20 x 140 mm 26 RE-2AS PTT Supply RE-2AS PTT dynamic microphone adds more versatility to your RE-2AS unit. This new device allows you to have a public announcement input right there at your fingertips. This Push To Talk microphone can be directly connected to the priority audio input to bypass the background music. As it is directly powered from the USB port inside the unit, you do not need to add an external power supply. Supply RE-2AS PTT dynamic microphone adds more versatility to your RE-2AS unit. This new device allows you to have a public announcement input right there at your fingertips. This Push To Talk microphone can be directly connected to the priority audio input to bypass the background music. As it is directly powered from the USB port inside the unit, you do not need to add an external power supply. 27 RE-2AS MPE Expansion unit model RE-2AS MPE for the paging microphone RE-2AS MP8Z. It has 8 software programmable buttons for paging up to 8 public address zones. It has an iron chassis to provide stability and protection against damages. All buttons are designed for an intensive use. Expansion unit model RE-2AS MPE for the paging microphone RE-2AS MP8Z. It has 8 software programmable buttons for paging up to 8 public address zones. It has an iron chassis to provide stability and protection against damages. All buttons are designed for an intensive use. 28 RE-2AS WMK Supply of the Wall mounting kit allows to install a PAVA unit on wall. It should be made of 1.5 mm galvanized sheet Supply of the Wall mounting kit allows to install a PAVA unit on wall. It should be made of 1.5 mm galvanized sheet 29 RE-2AS 4L Supply, installation, Testing, & commissioning of Network module to connect multiple PAVA systems., cable length Up to 200m per node and up to 4 units and 24 zones, 4 PAVA systems shall be network with length of max 800m,dimmensions (H x W x D)120 x 100 x 80 mm. Supply, installation, Testing, & commissioning of Network module to connect multiple PAVA systems., cable length Up to 200m per node and up to 4 units and 24 zones, 4 PAVA systems shall be network with length of max 800m,dimmensions (H x W x D)120 x 100 x 80 mm. 30 Supply, fabrication & Installation of thermal insulation on GI ducts complete with Closed Cell foam anti microbial insulation (Nitrile Rubber) with minimum density of 40 Kg/m3 with minimum R Value 4.1/inch & thermal conductivity -0.035 w/mok confirming to Class O & the inner side stuck to the outer facia of the GI ducts with recommended / Proprietory adhesive bonding inline with LEED requirements & installed as per manufacturers recommendation. The insulation joints shall be sealed with 3 wide Black Tape. Thermal Insulation - 9mm thick 31 Supply, fabrication and installation of acoustic lining of supply and return air ducts as specified and shown on the drawing complete with 10 mm thick acoustic insulation with Open Cell Foam Insulation - ArmasoundMicroban antimicrobial product protection withThermal conductivity 0.045 W/m deg.K / density 140~180 kg/m3, with manufacturer recommended adhesive inline with LEED requirement.Acoustic Insulation - 13mm thick 32 Electrical panel with outgoing for 2nos. Of VRV ODU and IDU 33 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 24W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Bodymade of Die cast Aluminium.Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 34 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 36W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 9300 Candella . Bodymade of Die cast Aluminium.Effective delivered lumens 3000-3200, ,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 35 Supplying, fixing and commissioning of Ground recessed Uplight for column, IP 67 RatedBody to be of High Grade Die Cast Aluminium with SS trim. Fixture to have 10w Led with Cool Touch Feature, Narrow 10 deg beam ,Color tempreture to be 3000k ,800-850 lumens, 90 Cri 3 Step Mac Adam with Remore Dali Driver, glare rating UGR<16. Lifespan ≥ 50000 hrs, Ambient temperature 25°-40° C, L&B Ratio L70/B20 with Lumen Maintenance LM80, Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 36 Supplying, fixing and commissioning of Surface Mounted Spotlight IP 65 with RAL finish LED 15W, 3000K CCT,Body Made of Die Cast Aluminium30 deg Medium beam . Effective delivered lumens 1350-1400, MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 37 Supplying, fixing and commissioning of Under Water Step Light IP 68 with RALfinish LED 5-8W, 3000K CCT, Medium beam.Effective delivered lumens 400- 600,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 38 Supplying, fixing and commissioning of Surface Mounted downlight IP 65 with RAL finish LED 20W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 39 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 24W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Bodymade of Die cast Aluminium.Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 40 Supplying, fixing and commissioning of Customized Deep mala Light IP65 with RAL finish LED 2-3W, 2400-2700K CCT, Diffused Beam° , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 80 including DALI driver.. Standard Warranty 5 Years. 41 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 15W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 3000 candella . Bodymade of Die castAluminium. Effective delivered lumens 1200-1400,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 42 Supplying, fixing and commissioning of Ground recessed Uplight for column, IP 67 RatedBody to be of High Grade Die Cast Aluminium with SS trim. Fixture to have 10w Led with Cool Touch Feature, Narrow 10 deg beam ,Color tempreture to be 3000k ,800-850 lumens, 90 Cri 3 Step Mac Adam with Remore Dali Driver, glare rating UGR<16. Lifespan ≥ 50000 hrs, Ambient temperature 25°-40° C, L&B Ratio L70/B20 with Lumen Maintenance LM80, Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 43 Supplying, fixing and commissioning of Surface Mounted Adjustable Spotlight , Auminium Die Cast Body, IP 65 Ratedwith RAL finish LED 15W, 3000K CCT, Medium beam . Effective delivered lumens 1200-1300, MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 44 Supplying, fixing and commissioning of Adjustable Mini Surface Mounted Spotlight IP65 Body to be made of Die Cast Aluminium with RAL finish LED 3W, 3000K CCT, Narrow 15 degbeam . Effective delivered lumens 40-50 , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Additional mounting accessories : Honeycomb louvre. Standard Warranty 5 Years. 45 Supplying, fixing and commissioning of Adjustable Mini Surface Mounted Spotlight IP65 Body to be made of Die Cast Aluminium with RAL finish LED 5W, 3000K CCT, Narrow 15 degbeam . Effective delivered lumens 150-200 , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Additional mounting accessories : Honeycomb louvre. Standard Warranty 5 Years. 46 Supplying, fixing and commissioning of Recessed Linear Grazer Die Cast Aluminium Body with SS Trim,LEDwattage to be 10-14W/m RGBW CCT Grazer 10x24 deg Optic,Remote Dali Dimmable, Delivered lumens: 500-600Real lm/m,glare rating UGR<19L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90.. Standard Warranty 5 Years. 47 Supplying, fixing and commissioning of Surface MountedLinear Grazer IP 67 ratedDie Cast Aluminium Body with adjustable Brackets, LED wattage to be 15W/m 3000K CCT Garzer 10x24 deg Optic,Remote Dali Dimmable, Delivered lumens:Real 1200lm/m,glare rating UGR<19L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90.. Standard Warranty 5 Years. 48 Supply, Installation, Testing and Commissioning ofAdjustable Gobo Projector Light , Body to be Made of Die cast Aluminium, Wattage of 180w Beam, 5200 lumens, 4 Gobo Modules , IK 08 CCT 7000k , Degree 15-45 deg Motorized Zoom, IP 66 rated. CRI >70. Driver Inbuilt DMX RDM Controlled. Life time of Led L70B20 @ 35000 hrs. Gobo design to be decide by Architect/Lighting Designer. 49 Supplying, fixing and commissioning of Post Top LuminaireIP65 & IK10 with RAL finish, LED 40W, 2200K CCT, Symmetrical beam optics. Effective delivered lumens 2000-2200 lumensMacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, Ambient temperature < 40° C, L&B Ratio L80/B20 with Lumen Maintenance LM80, CRI 80+. Standard Warranty 5 Years 50 Supply, Installation, Testing and Commissioning ofPole Mounted Adjustable Gobo Projector Light having Wattage of 40W and Delivered Lumens of 2500. Beam Degree 17-30., IP 65 rated with Pole mounting Bracket. CRI >70. Driver to be non dimmable and Integrated. Life time of Led L70B20 @ 35000 hrs. Gobo design to be decide by Architect/Lighting Designer.Including 4mtr. pole (procurred locally) 51 Supply, fabrication, and installation of a custom-made heritage chandelier of diameter 2000 mm and height 2000 mm, made from heavy-duty metal frame with antique brass / bronze / gold leaf finish as approved by the architect. The chandelier shall include precision-cut K9 / lead crystal elements in pendants, prisms, and beads, arranged in multi-layer form to create a grand decorative effect. Fixture shall be suitable for E14 / E27 LED lamps or integrated LED modules, providing warm white light (2700K–3000K) with CRI ≥ 90 and dimmable control.Suspension shall be with heavy-duty chain/rod system and canopy plate designed to safely carry the total load with 3× safety factor. All wiring shall be flame-retardant copper with proper earthing. The chandelier shall comply with IEC / IS standards and be supplied with shop drawings, finish samples, and load details for approval. Minimum warranty: 5 years. 52 Supply, Installation, Testing and Commissioning of Decorative Wall Light. Housing: IP65 & IK10 with RAL finish, LED 40W, 2200K CCT, Symmetrical beam optics. Effective delivered lumens 2000-2200 lumensMacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, Ambient temperature < 40° C, L&B Ratio L80/B20 with Lumen Maintenance LM80, CRI 80+. Standard Warranty 5 Years 53 Supply, Installation, Testing & Commissioning of International seeTouch QS Wallstation Insert 5 Button with Raise/Lower QSWE-5BRL 54 Supply, Installation, Testing & Commissioning of DALI Dimming controller; Controls 2 independent DALI links with up to 64 DALI ballasts per link. Can take care of Color Tunable fixtures. 4 groups of sensors inputs: Occ sensor, daylight sensor and IR sensor. Requires mains/line voltage feed Similar to Lutron QSN-2UNVDAL- D 55 Supply, Installation, Testing & Commissioning of Switching module with 4channels, each channel with minium 5 amp rating with provisions of sensors inputs: Occ sensor, daylight sensor and IR sensor. Requires mains/line voltage feed Similar to Lutron QSNE-4S 5230D module 56 The QSE-CI-DMX control interface allows zones on a to control DMX512-controlled devices Any zone can be mapped to either a single DMX512 channel or to three separate DMX512 channels, for RGB/CMY color-control The DMX channels (maximum of 32) are mapped to zones, and can be programmed as 1- channel lighting, 1-channel integration, or 3-channel RGB/CMY 57 Supply, Installation, Testing & Commissioning of central processor assembled processor with one/two configurable links and inbuilt BACnet for occupancy status. Each processor link can be configured to be a dimmer link, shade link, or dimmer power panel link. Processor accpets 220-240V, 1 phase, 2 wire, 10A feed, (throiugh power supply) Similar to Lutron Athena 58 Supply, Installation, Testing & Commissioning of Power Supply Unit for supply PDUs to Antenna devices Similar to Lutron QSPS-DH -1 -75Approved Makes :Lutron, Crestron, Pharos,Enlighten 59 Supply, Installation, Testing & Commissioning of Lighting control and monitor software, captures floor wise consumption, each event, Energy Reporting & monitoring per processor, 60 Supply, Installation, Testing & Commissioning of Lighting control BACnet softwares for BMS integration. This license for BACnet software enables a third-party building management system to control, monitor,and manage lights and shades in various areas on a processor. This license can also be used to share information between the control system and other control systems such as area occupancy, power usage, lighting state, etc. License required 1 per processor. 61 Supply of QS cable for power and data simialr to Lutron QS-CBL-LSZH Cable Adheres to CE standards for Low Smoke Generation (EN 60332-1-2), Halogen Gas Emission (EN 61034-2), and Flame Retardation (EN 60754- 1&2). • Five Conductors: Common – 0.75 mm2 (18 AWG) Power – 0.75 mm2 (18 AWG) MUX Data – 0.25 mm2 (22 AWG) _ Data – 0.25 mm2 (22 AWG) Drain Wire – 0.2 mm2 (24 AWG) Laying in suitable conduits to be done by Electrical contractor. 62 The scope of work includes the supply, installation, testing, and commissioning of asuitable Distribution Board (DB) box for mounting dimming and switching modules,complete with all necessary accessories such as enclosures, busbars, terminalblocks, MCBs, internal wiring, and supports, as per approved drawings andspecifications; the DB box shall be of robust construction, properly ventilated, factoryfinished, and designed to facilitate easy integration with the Lighting ManagementSystem, ensuring safe, reliable, and efficient operation after successful testing andcommissioning. 63 Programming of complete systemThe scope of work includes the complete programming, testing, and commissioningof the Lighting Management System (LMS), covering configuration of lighting zones,dimming levels, sensors, and schedules as per the approved control philosophy,integration with BMS/third-party systems if required, point-to-point and functionaltesting of all devices, fine-tuning and calibration, preparation of test reports and asbuilt documentation, and providing necessary training to client/end-user staff toensure the LMS is fully functional, compliant, and ready for handover. 64 Supplying, erecting, testing and commissioning of diesel generating set with alternator of 160 kVA confirming to CPCB IV Plus emmision compliant with output continuous rating. 3 Phase. 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed (liquid cooled multi-in line cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/-5%, with performance class G2. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears,indicators connected with suitable zires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m. with suitable capacity DEF tank provided with first Filling of oil, diesel tank capacity not less than 385 Ltr etc. on provided M20 Grade CC Foundation and obtaning necessary aproval from electrical inspector if necessary. This DG Set is fiited in sound prof and whether proof Acoustic Enclosure asper CPCB IV plus emisison complaint as per specification no. GEN-DG
Contract Date: Jun 19, 2026 Contract Value : 1.28 Crore
Government Departments No of Bidders 3
Maharashtra View Result →
4.
Housing Urban and Rular Development #11311754 Technical Bid
Tender for 1. Sculpture - MahobaS Betel Leaf - Technical Specification Desiging, Providing, Fabricating, And Installing 10 Ft High (7 Ft Sculpture + 3 Ft Plinth) Frp Sculpture, Executed In Premium-Grade Uv-Stabilized Frp Laminates Minimum 8 Mm Thick, Manufactured Using Chopped Strand Mat (Csm) 450 Gsm And Woven Roving 600 Gsm With Iso-Grade Resin System, Gelcoat Finish And Polymer Hardener. Frp To Be Formed Over A Fabricated Ms Structural Armature Using Ms Square/Round Pipe Section (Minimum 50×50×2.5 Mm Thick), Including Full Welding, Grinding, Stress-Relief, And Two Coats Of Zinc-Rich Epoxy Primer Followed By Polyurethane (Pu) Topcoat On Metal Elements. Surface Finishing To Include Mirror-Finish Inlays Fixed With Industrial-Grade Adhesive As Per Approved Motif Layout And Embedded Bundelkhandi Folk Motifs Engraved Or Cast Within Frp Layer. Plinth To Be Constructed In M-20 Grade Reinforced Cement Concrete With Reinforcement Confirming To Is:456, Shuttering With Waterproof Ply, Finishing, And Integrated Chemical Anchor Bolts (Hilti/Equivalent) For Anchoring Ms Frame To Rcc. Plinth Outer Surface To Be Clad In Polished Red Sandstone 20-25 Mm Thick, Machine-Cut, Fixed Using Stainless Steel Cramps/Clamps (Grade 304) And Polymer-Modified Adhesive With Pointing In Pigment-Matched Epoxy Grout. Brass Nameplate (8-10 Mm Thick) With Deep-Engraved Lettering To Be Installed With Countersunk Ss Screws. Electrical Work Includes Rgb Uplighters (2 Nos. - Ip67, Ik08) With In-Built Charge Controller, Panel Mounting Brackets, Concealed Wiring With Uv-Resistant Cable, Junction Boxes, And Testing. Rgb Lighting System: Providing And Laying Programmable Rgb Led Linear Strip/Flood Lighting, Ip65-Rated, High-Power 5050/3528/2835 Chipset, With Aluminum Channel Fixing, Silicone Encapsulation, 12V/24V Driver, Dmx-Compatible Controller, Power Supply Control Board, Weatherproof Junction Box, Flexible Conduits, Cable Routing Through Gi/Hdpe Conduit (Minimum 25 Mm Dia.), Including Termination, Tagging, Ferrule, Testing, Commissioning, And Integration With Existing Supply. Complete Including All Labour, Tools, Plants, Scaffolding, Anti-Uv Coating, Joint Sealing, Curing, Protection, And Finishing As Per Approved Drawings And The Direction Of Engineer-In-Charge. , 2. Sculpture - The Elder Craftsman Desiging, Fabrication Of 11 Ft High Life-Size Artisan Sculpture, Executed In Frp 6-8 Mm Thickness, Produced Using Hand Lay-Up Process, Reinforced With Csm 450 Gsm And Woven Roving 600 Gsm, Surface Gelcoat Resistant To Uv & Atmospheric Conditions. Internal Ms Support Frame Fabricated With Is 806/Is 1161 Compliant Steel Tubes, Welded As Per Is: 816, Ground Smooth, Inspected By Dye-Penetration Testing At Joints, And Coated With Zinc-Rich Epoxy Primer And Pu Topcoat. Sculpted Tools (Hammer, Chisel, Stone Block) To Be Integral Frp Components Reinforced With Ms Inserts Where Necessary. Exterior Finishing In Bronze Patina Multi-Layer System Including Base Coat, Shading Coat, Glaze, And Weather-Protective Clear Pu. Base: 3.5 Ft Reinforced Cement Concrete Pedestal (M-20), Steel Reinforcement Fe-500 Grade, Chemical Anchor Fixing System, Clad With Premium-Grade Granite Slabs (20-25 Mm Thick), Polished To 800-1000 Grit, Chamfered Edges, Fixed With Stainless Steel Clamps And Polymer-Based Adhesive. Rgb Lighting System: Supply And Installation Of Rgb Led Linear Lights/Spot Fixtures, Ip65/Ip67-Rated, With Aluminum Extrusion Channels, Pvc/Silicone Sealing, Dmx Controller, Waterproof Driver, 16-18 Gauge Copper Wires, Gi Conduits, Mcb Protection, Synchronization Of Lighting Sequences, Testing & Commissioning. Includes Earth Connection As Per Is:3043, Foundation Excavation/Backfilling, Hoisting, Alignment Using Spirit Level And Temporary Supports, Protective Anti-Uv Coat, Finishing Complete , Sculpture - Egksck Dk Lw;Z Eafnj (Sun Temple Of Mahoba) Desiging, Providing And Erecting 10 Ft High Frp Sculpture (10 Mm Thick) Fabricated Using Dual-Layer Woven Roving 600 Gsm And Csm 450 Gsm With Isophthalic Grade Resin System, Designed With Embedded Transparent/Colored Acrylic Panels (6-8 Mm Cast Acrylic) Supported Within Frp Recesses. The Sculpture Includes Internal Led Illumination Cavity With Access Hatch. Internal Ms Structure Designed As Per Structural EngineerS Certification For Wind Loadings Up To 180 Km/H. Surface Finishing To Be Golden Metallic Enamel, Multi-Coat System With Primer, Metallic Flakes Coat, Final Pu Topcoat. Base: 4 Ft Reinforced Cement Concrete Pedestal, Reinforcement Detailing As Per Structural Drawing, Fully Clad With Jaisalmer Yellow Stone, Machine-Cut And Mirror-Polished, Fixed With Ss Cramps. Electrical Works Include Ip-Rated Internal Led Modules, Drivers, Controller, Cable Trays Inside Sculpture, And Maintenance Access Door. Rgb Lighting System: Providing And Installing Rgb Led Accent Lighting, Ip65-Rated, With Programmable Controller, Dmx Interface Module, Gi Conduit, Copper Wiring, Junction Boxes, Mcb Protection, Earth Continuity Conductor, And Full Testing And Commissioning. Complete Including Foundation, Anchoring, Grouting, Cable Management, And Surface Finishing As Per Drawings. , 4. Sculpture - Fort Of Mangalgarh Desiging, Fabrication And Installation Of 10 Ft High Sculpture Made Of Treated Steel Scrap, Utilizing Ms Plates, Rods, Flats, Angles, Bars Of Select Thickness (4 Mm-10 Mm), Cleaned By Sandblasting (Sa 2.5 Standard), Welded Using Is-Approved Welding Electrodes, Full Penetration Welds Where Required, Visually Inspected And Tested. Surface To Undergo Rust-Induced Patina Treatment Through Chemical Oxidation, Sealed With Clear Epoxy Topcoat (2-3 Layers). Sculpture Supported On Heavy-Duty Internal Ms Frame Anchored To Reinforced Cement Concrete Plinth (M-20 Grade) Clad With Natural Stone (Random/Ashlar Masonry), Fixed With Ss Clamps. Rgb Lighting System: Providing And Fixing Rgb Led Flood Or Strip Lights, Ip65/67-Rated, On Anti-Corrosion Metal Brackets, Concealed Wiring, Dmx/Ir Controller, Driver Unit, Gi Conduit, Cable Protection, Mccb/Mcb As Required, Tagging, Termination, Testing, And Commissioning. Includes All Corrosion-Treatment Stages, Structural Frame Fabrication, Erection, Foundation Concreting, Anchor Bolt Fixing, Finishing Complete. , 5. Sculpture - Raja Parmal Desiging, Fabrication And Erection Of 12 Ft High Equestrian Statue, In Frp 10 Mm Thickness, Gel-Coated Finish, Multi-Layer Lamination, Sculpted Detailing On Armour, Horse Musculature, Ornaments, Weaponry. Internal Ms Structural Frame Designed With Triangulated Truss Geometry Ensuring Stability Against Wind-Induced Vibrations; Steel Tubes Treated With Sandblasting And Epoxy Primer. Plinth: 4 Ft Reinforced Cement Concrete Base With Fe-500 Reinforcement, Fully Clad With High-Grade Granite Slabs, Fixed With Ss Cramps (Grade 304/316). Engraved Stone Plaque Fixed With Hidden Anchors. Surface Finish: Antique Bronze Metallic Finish With Multi-Layer Pu Protective Coating. Rgb Lighting System: Installation Of Rgb Programmable Spotlight Array, Ip67-Rated, Dmx-Controlled, Drivers, Dimmers, Gi Conduits, Ryb Phase-Balanced Power Distribution, Earthing Per Is:3043, Labeling, Cable Routing, Testing & Commissioning. All Structural Fixing, Grouting, Verticality Adjustment, Surface Cleaning, And Protection Complete. , 6. Sculpture - Alha Desiging, Providing, Fabricating, And Installing 11 Ft High Frp Sculpture (8 Mm Thick), Layer Composition Csm 450 Gsm + Woven Roving 600 Gsm, High-Impact Resin System With Uv Stabilizer. Internal Structural Frame Fabricated Using Ms Pipes (50×50×2.5 Mm Min.), Epoxy Coated, Welded To Base Plate Fixed With Chemical Anchors. Mounted On Circular Reinforced Cement Concrete Plinth (M-20), Clad In Sandstone Slabs With Fine Chiselled Finish. The Base Includes Engraved Verse From Alha-Khand On Brass/Stone Plaque. Surface Finishing To Include Dark Bronze Metallic Paint, Pu Topcoat, Uv-Resistant Sealant. Rgb Lighting System: Providing And Fixing Ip65-Rated Rgb Led Edge-Lighting System Concealed In Plinth Recess, Provided With Dmx Controller, Drivers, Gi Conduit, Wiring, Earthing, And Commissioning. Includes Excavation, Foundation Concreting, Grouting, Anti-Uv Protective Coating, Finishing Complete. ,. Sculpture - Udal Desiging, Fabrication And Installation Of 11 Ft Dynamic Warrior Sculpture, Frp (8 Mm Thickness Minimum), Reinforced With Multi-Layer Frp Lamination, Internal Ms Structural Backbone Designed For Dynamic Cantilever Stresses Using Analysis Inputs. Dual-Tone Bronze-Steel Patina Finish By Multi-Layer Painting System. Mounted On Reinforced Cement Concrete Plinth (M-20), Granite Cladding 20-25 Mm Thick, Stainless Steel Cramps, Polymer Adhesive. Rgb Lighting System: Supply And Installation Of Rgb Led Spotlight/Linear Lighting System, Ip65/Ip67-Rated, Programmable, Including Driver, Controller, Conduits, Control Wiring, Earthing, Load Balancing, Testing, Commissioning. Includes Alignment, Installation, Anchor Bolt Tightening, Surface Finishing, Cleaning Complete In All Respects. , 8. Sculpture - Gorakhgiri Desiging, Providing And Fixing Spiritual Sculpture Depicting Gorakhnath Within An Abstract Hill-Form, Fabricated In Frp 10 Mm Thickness, Reinforced With Ms Skeleton Frame, Stress-Tested, Epoxy-Coated. Stone-Texture Frp Surface Created Using Multi-Layer Texture Coat, Shading Coat, And Final Weatherproof Pu Coat. Mounted On 3.5 Ft Reinforced Cement Concrete Plinth Clad With Sandstone, Fixed With Ss Cramps And Epoxy Adhesive. Brass Nameplate Fixed Flush. Optional Halo-Effect Led Illumination Integrated Within Sculpture With Concealed Access For Maintenance. Rgb Lighting System: Providing And Fixing Rgb Led Backlighting/Edge Lighting, Ip65/Ip67-Rated, Driver-Controlled, Dmx Controller Integration, Gi Conduit, Cable Management, Termination, Testing, Commissioning. Includes Foundation, Anchoring, Hoisting, Structural Inspection, Protective Coatings, Finishing Complete As Per Direction Of Engineer-In-Charge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
Uttar Pradesh View Result →
6.
Educational and Research Institute #11299551 Price Bid
Tender For Supply Of Library Books , Library Books (Refer Nit) , Industrial Safety And Human Behaviour Kaila 9788174734532 , Engineering Mechanics Vela Murali Bks456005 , Earthquake Resist Design Structural Shashikant Dugg Bks643652 , Surveying And Levelling Subramanian 9780198085423 , Practical Railway Engineering, 2Nd Ed Clifford Bonnett 9780000990136 , Geographic Information Systems Gis For Disaster Management 2Ed Brain 9781032552460 , Design Of Structural Elements Chanakya 9781138046436 , Wind Loading Of Structures 3Rd Edition John D. Holmes 9780367241803 , Structural Analysis 3/Ed Menon 9788184877342 , Concrete Pipes And Pipelines Joshi Bks426990 , Strength Of Materials Basavarajaiah 9788173714580 , Geotechnical Engineering Debashis Moitra 9788173719905 , Textbook Of Environmental Studies For Undergraduate Courses 3 Ed Bharucha 9789389211788 , Intelligent Transportation Systems Srinivasa Kumar 9788195400928 , Transportation Engineering Srinivasa Kumar 9789389211160 , Structural Analysis With Finite Elements Hartmann 9788132208945 , Strength Of Materials Vol 1 Binu Sukumar 9789388005029 , Geospatial Technology Dwivedi 9789380381480 , Heavy Metal And Metalloid Contamination Of Surface And Underground Water Gupta A. 9781032728582 , Fundamentals Of Environmental Engineering Danny D Reible 9781566700474 , Computer-Aided Highway Engineering S Goswami 9781032728483 , Fundamentals Of Hydrology Davie 9781032251936 , Highwall Mining : Applicability, Design & Safety Porathur J. L. 9781032728919 , Environmemtal Pollution Control Engineering 4Ed Rao 9788122472288 , Plane Surveying 3Ed Chandra 9788122438802 , Design Of Reinforced Cement Concrete Vol 1 Structural Elements Bhavikatti 9788122440515 , Strength Of Materials, 2/Ed Jindal 9789352861521 , Fundamentals Of Hydraulic Engineering Sy Houghtalen 9789332507593 , Geotechnical Engineering Coduto,Yeung 9789332587427 , Strenth Of Materials Jindal 9788131759097 , Dynamics Of Structures 2Nd Ed Jain 9789357059350 , Finite Element Method With Cd Eldho Desai Shah 9788131724644 , Soil Mechanics And Foundation Engineering Purushotama Rai 9788131790816 , Engineering Mechanics - Statics & Dynamics Shames Rao 9788177581232 , Dynamics Of Structures In Si Unites 5Ed Chopra 9789353945251 , Elementary Engineering Hydrology Deodhar 9788131708057 , Environmental Studies Basak 9788131721186 , Introduction To Finite Elements In Engineering 5/E Tirupathi 9781009461818 , Strength Of Materials Rao 9781108454285 , Plumbing Engineering Nikhil Anthony 9788119365128 , Fundamental Of Ground Improvement Engi Prof.Dr.R.K. Khit 9788195916948 , Surveying And Levelling : Part - 1 Kanetkar Kulkarni Bks644037 , Surveying And Levelling : Part - 2 Kanetkar Bks644038 , A Textbook Of Strength Of Materials Rajput 9789355010704 , Building Construction Bhavikatti 9789325960794 , Fundamental Of Reinforced Concrete Chandra Bks498526 , Irrigation Engineering And Hydraulic Structures Sharma Bks535826 , Surveying I Anne Mary 9788183717304 , Highway Engineering Subramanian 9788183716888 , Strength Of Materials Bansal Bks534222 , Reinforced Cement Concrete Design (Reinforeced Concrete Structures) Punima 9788131809426 , Building Construction Rangwala Bks502124 , Civil Engineering Drawing Rangwala Bks440591 , Soil Mechanics & Foundation Engineering Modi 9788189401306 , Engineering Materials Rangwala Bks385325 , Bridge Engineering Rangwala Bks554100 , Harbour Dock And Tunnel Engineering Srinivasan Bks502125 , Solid Hazardous Watse Management 2Ed Rao 9789389354621 , Textbook Of Remote Sensing And G.I.S 4Ed Reddy 9789381075975 , Reinforced Concrete Design P.B Sharma 9789391910419 , Energy Environment Ecology And Society Anil Kumar 9788178002576 , Solved Problems In Geotecnical Engineering Sharma 9789395038478 , Highway Engineering Suganthi Bks411034 , Highway And Railway Engineering Santhanam Bks638485 , Construction Materials & Tech Mathankumar Bks638450 , Prefabricated Structures Soundrarajan Bks638488 , Structural Analysis-I Santhanam Bks479564 , Green Building Design Molykutty Bks503088 , Irrigation Engineering Basak 9780074635384 , Estimating Construction Costs Peurifoy 9780071239455 , Design Of Steel Structure Duggal 9780070260689 , Concrete Technology Gambhir 9781259062551 , Engineering Mechanics Timoshenko 9781259062667 , Flow In Open Channels Subramanya 9789353166298 , Reinforced Concrete Design 4Ed Pillai 9789354601026 , Surveying Vol - Ii 5Th Edn Duggal 9789353167523 , Surveying And Levelling Basak 9789332901537 , Prestressed Concrete 6Ed Krishna Raju 9789387886209 , Fluid Mechanics White 9789355322043 , Strength Of Materials Rattan 9789385965517 , Surveying Vol - 1 Duggal 9789353167509 , Environmental Studies-3Ed Joseph 9789352605170 , Construction Planning, Equipment Peurifoy 9780070706996 , Fluid Mechanics Fundamentals And Applic Cengel 9789353166212 , Schaums Outline Of Finite Element Analysis Buchanan 9789389691375 , Wind Energy Theory And Practice 3Ed Ahmed Bks662294 , Bituminous Road Construction In India Kandhal 9789391818821 , Mechanics Of Composite Structures Vasiliev 9781138582101 , Satellite Towns In Neometropolitan Development In India Amit Chatterjee 9789811932052 , Sustainable By Design Walker 9781032973685 , Management Of Quality In Construction Ashford 9781138607163 , Disaster Managament 2/Ed Pandey 9789357461610 , Remote Sensing And Image Interpretation Thomas Lillesand 9789354642104 , Composite Structures Of Steel And Concrete 3Ed Johnson 9788126539819 , Strength Of Materials 2Nd/Ed Debabrata Nag 9788126534876 , Reasoning Ability And Quantitative Aptitude Tcy Online 9788126559008 , Green It Strategies And Applications Using Envir Intell Bhuvan Unhelkar 9781032054025 , Bioenergy For Sustainability And Security Behera 9789381891438 , Textbook Of Engineering Geology Annadurai 9789385259937 , Structural Dynamics Mukhopadhyay 9788180520907 , Matrix And Finite Element Analysis Mukhopadhyay 9788180520754 , Irrigation Engineering & Hydraulic Structures Suresh 9789383656899 , Strength Of Materials 2Ed Vendateshan 9789383656646 , Concrete Technology Job Thomas 9788131526682 , Steel Design Segui 9788131526651 , A First Course In The Finite Element Methods Logan 9789353507855 , Civil Engineering Materials Sivakugan Tuladhar 9789386650382 , Soil And Water Conservation Engineer Fangmeier 9788131524985 , Principles Of Foundation Engineering 9Th Ed Das 9789355738110 , Elements Of Civil Engineering Balasubramanya 9789387511576 , Soil Mechanics & Foundation Engineering Huat Prasad 9788131529591 , Principles Of Foundation Engineering Das 9789386650955 , Analysis Of Structures On Elastic Tsudik 9788131518953 , Strength Of Materials : Mechanics Gupta 9789355737717 , Steel Design With Mt Segui 9789386650887 , Prestressed Concrete Structures, 6Ed Dayaratnam 9788120417915 , Fundamentals Of Reinforced Cement Concrete Designs Gahlot 9789385915611 , Instrumental Methods Of Analysis Willard 9788123909431 , Tb Of Soil Mechanics And Foundation Engineering:Geo Technical Engg Murthy 9788123913629 , Civil Engineering Through Objective Type Questions 3Ed Gupta 9788123907970 , Advanced Reinforced Concrete Design 3Ed Raju 9788123929606 , Design Of Reinforced Concrete Structures 4Ed Dayaratnam 9788120414198 , Structural Dynamics Paz 9788123909783 , Modern Prestressed Concrete Libby Bks465269 , Textbok Of Solid Wastes Managemnt Khan 9788123909448 , Analysis & Design Of Substructures, 2Ed Swami Saran 9788120417007 , Building Repair And Maintance Management Gahlot 9788123912431 , Advanced Foundation Engineering Murthy 9788123915067 , Modern Construction Management 7Ed Harris 9788126572298 , Groundwater Hydrology Rushton 9788126539772 , Textbook Of Highway And Traffic Engineering Saxena 9788123924175 , Airport Engineering Saxena 9788123915500 , Construction Dewatering And Groundwater Control 3Ed Powers 9788126541669 , Quality Management Of Cement Concrete Construction (Pb) Gahlot 9788123916989 , Tb Of Water Supply And Sanitary Engineering Husain 9788120416833 , Design Of Bridges 5Ed Raju 9788120417984 , Essentials Of Bridge Engineering 6Ed Victor 9788120417175 , Building Construction Handbook Chudley 9789381269169 , Design And Construction Of Concrete Shell Roofs Ramasamy 9788123909905 , Strength Of Materials, Vol-Ii:Advanced Theory And Problems Timoshenko 9788123910772 , Construction And Project Managment 2Ed (Pb 2018) Krishnamurthy 9789386217790 , Water And Wastewater Calculations Manual 2Ed Lin 9789353162863 , Design Of Stell Structures Abu-Saba 9788123905389 , Prestressed Concrete Problems And Solutions Raju 9788123925424 , Water Resources And Irrigation Engineering Ganesaguru Bks588955 , Dam Engineering Asthana 9789381891469 , Sedimentary Rocks In The Field A Colour Guide Stow 9781874545699 , Soil Mechanics Basic Concepts & Engineering Aysen 9780415383936 , A Tb Of Fluid Mechanics And Hydraulic Machines Bansal Bks493063 , Intelligent And Sustainable Cement Production Chatterjee A.K. 9781032728445 , Total Quality Management 5Ed Besterfield 9789353066314 , Matrix Methods Of Structural Analysis Kothandaraman 9789357059190 , Hydraulics And Fluid Mechanics Hydraulic Machine Modi , Seth Bks291963 , Limit State Design Of Steel Structures Duggal 9789353164874 , Schaums Outline Of Reinforced Concrete Everard 9789389538656 , Earthquake Resistant Design Of Structures Agarwal Bks344533 , Building Materials Varghese 9788120350915 , Total Quality Management 2Ed Mukerjee 9788119364299 , Principles Of Geotechnical Engineering 10 Th Ed Das 9789355738103 , Building Materials Products Properties And Systems Gambhir 9780071077606 , Gate 2025 Civil Engineering - Guide By Gkp C L Educate 9789356817593 , Gate 2025 Mechanical Engineering Guide Gkp 9789356817746 , Engineering Design Dieter 9789355322258 , Economics And Principles Of Management Vinoth Kumar 9788194244646 , Vector Mechanics For Engineers Dynamics Beer 9789353166656 , Aviation Maintenance Management Kinnison 9780071076838 , Theory Of Machines S S Rattan 9789353166281 , Turbomachinery Dubey 9789353161156 , Engineering Mechanics 4/E Kumar 9780070681811 , Modern Compressible Flow: With Historica Anderson 9789355320070 , Programming In Matlab Patel Mittal 9789332524811 , Finite Element Analysis Moaveni 9788131760642 , Non Conventional Energy Resources Sobh Nath Singh 9789332543577 , Additive Manufacturing And 3D Printing Technology Awari Thorat 9781041049562 , Practical Guide To Vehicle Refinishin Woodstock 9781032963570 , The Internet Of Mechanical Things The Iot Framework Sami Salama Hussen 9781041038573 , Energy Storage Systems And Components Alfred Rufer 9781041049470 , Metal Cutting Theory & Practice Stephenson 9780824758882 , Classical Mechanics Problems And Solutions Carolina C Llie 9781032983608 , Product Design Baxter 9781032967882 , Thermal Measurements & Inverse Tech Orlande 9781439845554 , The Induction Machines Design Handbook Boldea Bks331229 , Modeling And Control Of Engineering Systems Clarence W. De Silva 9781420076868 , Fundametals Of Production Planning And Control Chapman 9788131717394 , Applied Thermodynamics For Engineering Technologist 5Ed Eastop 9788177582383 , Classical Mechaincs Goldstein 9788131758915 , Introduction To Robotics Saha 9789355326461 , Thermodynamics-Basc And Applied Ganesan 9789353161279 , Ethics In Engineering 5/Ed Martin 9789355325075 , Digital Marketing Chaarlas 9788119243983 , Non Conventional Energy Resources Khan 9789352601882 , Supply Chain Logistics Management Bowersox 9789353162580 , Mechanical Metallurgy Appuraj Thiyagrajan Deiter 9781307834840 , Schaums Outline Of Continuum Mechanics Mase 9789389691283 , Schaums Outline Of Statics And Mechanics Of Materials Nash 9789389691399 , Maleev & Hartmans Machine Design 6Ed Grover 9788123926322 , Mass Transfer Theory And Applications Narayanan Bks440952 , Manual Of Fire Safety Prakash 9788123919904 , Gpropulsion Systems For Space Applications Satyanarayana 9789395038553 , Mechanics Of Materials Si Version 5Ed Philpot 9789354643293 , Introduction To Robotics 3/Ed Niku 9789357461306 , Advanced Mechanics Of Materials 6Ed Boresi 9788194726395 , Design And Analysis Of Experiments Douglas & Montgomery 9788126540501 , Machine Component Design Robert C.Juvinall 9788126559732 , Callisters Materials Science And Engineering, 2Nd Ed Balasubramaniam 9788126541607 , Process Dynamics And Control 4Ed Dale Seborg 9789354248429 , Engineering Optimization Theory And Practice 5Ed Rao 9789357461238 , Principles Of Modern Manufacturing Si Version Groover 9788126573059 , Convective Heat And Mass Transfer South Asian Edi Mostafa Ghiassiaan 9781107511811 , Continuum Mechanics Jog C S 9781108437141 , Singers Engineering Mechanics Statics & Dynamics ( Si Units ) 3Ed Vijay Kumar 9788178002194 , Analytical Mechanics Fowles 9788131501115 , Thermal Sciences Potter Scott 9788131529461 , Physical Metallurgy Principles Abbaschian 9788131520697 , Additive Manufacturing Technology Hari Prasad 9789353500481 , Computational Fluid Dynamics & Heat Ghosh Dastidar 9788131533079 , Internet Mrketing With Mt Zahay 9789355734570 , Mechanical Vibrations Theory And Applications Kelly 9788131526033 , Mechanics Of Materials, Enhanced Edi Goodno--Gere 9789355737847 , Fundamentals Of Mechatronics Jouane 9788131526026 , Mechanics Of Materials Strength Of Materials Pilli/Bala 9789386668509 , Workshop Manufacturing Practices Ai Juneja 9789387994614 , The Finite Elements Methods - Its Basis & Fundamentals 7/Ed Zienkiewiez 9789351071587 , Automation And Collaborative Robotics (Dp) Mathews 9781484277102 , The Robotic Process Automation Handbook : A Guide To Implementing Ri Systems Taulli 9781484275306 , Materials Selection In Mechanical Design 5Ed Ashby 9789351073864 , Industry 4.0 : The Industrial Internet Things Gilchrist 9781484249703 , The Finite Element Method A Practical Course 2Ed Liu 9789351071594 , Elasticity-Theory, Applications & Numerics 2Ed Sadd 9789351072270 , Energy Resources And Their Utilisation R.K. Khitoliya 9789394917040 , Workshop Theory And Practice Delilah Sam 9788119365098 , New Persp. In Hybrid Vehicle Technology Samual Rodrigues 9788119365418 , Natural Gas Engineering Selvin 9788119365197 , Machine Shop Theory Samual Rodrigues 9788119205639 , Applied Mechanics Laboratory Samual Lobo 9788119365760 , Robotics: Emerging Opportunities Adrian Dsilva 9788119523702 , Advances In Hypersonic Vehicles Samual Rodrigues 9788119365500 , Machine Elements Samual Rodrigues 9788119205691 , Work And Energy Parth Chavda 9788119365234 , Design Thinking : A Comprehensive Textbook Tiwari 9789357468640 , Welding Technology Sanfras Monteiro 9788119523023 , Combustion Engineering Samual Rodrigues 9788119205943 , Fluid Machinery Noel Vincent 9788119365029 , Renewable Energy Roy 9789384007157 , Engineering Graphics Using Autocad 7/Ed {Pb} Elanchezhian C 789387938564 , Introduction To Micromachining 2Ed Jain 9788184873610 , A Systems Approach To Automotive Technology Erjavac 9788131512111 , Emotionally Intelligent Design Pavliscak 9789352138029 , Mechanics Of Solids Binu Sivakumar 9789380381671 , Mechanics Of Solids Christian Johnson 9789385983085 , Jet Engines Jaganathan 9789380381497 , Essentials Of Management, 11Ed Koontz 9789353168148 , Disaster Management Subramanian Bks481407 , Engineering Fluid Mechanics Kumar Bks613447 , A Textbook Of Fluid Mechanics Rajput Bks648302 , A Textbook Of Thermal Engineering ( Lpspe ) Khurmi Bks613483 , Materials Science And Engineering Raghavan 9788120350922 , Engineering Economics 2Nd Ed Panneerselvam Bks661039 , A Tb Of Theory Of Machine Gupta R Khurmi Bks408347 , Energy Security And Sustainability Shukla A. 9781032728926 , Mechanical Engineering Jain Bks554131 , Engineering Materials And Metallurgy Annamalai 9789386235046 , Kinematics Of Machinery Baskar Bks462932 , Thermal Engineering Swaminathan Bks638475 , Engineering Materials And Metallurgy Baskar Bks638439 , Lean Manufacuring Kalyana Chakravarthy Bks638464 , Elements Of Mechanical Engineering Singh Bks448529 , Fundamentals Of Manifacturing Engineering Singh 9789380156002 , Strength Of Machine Elements Ghorpade 9789384726003 , Observability Engineering Achieving Production Excellence Majors 9789355422996 , Research Methodology 5Ed Kothari 9789389802559 , The Automotive Body Vol 2 Morello 9788132208884 , Kinematics Of Machines Kumar 9789388005425 , Essentials Of Heat And Fluid Flow In Porous Media Narasimhan 9789382127215 , Analysis Of Composite Structures Decolon 9789380931463 , Theory Of Elasticity Chandramouli 9789380381633 , Principles Of Composite Material Mechanics 3Ed Gibson Bks380369 , Introduction To Combustion Engineering Basic And Applied Amitava Sarkar 9789357053129 , Textbook Of Finite Element Analysis Seshu Bks414440 , Engineering Thermodynamics Savithiri Bks442773 , Automobile Engineering Vol-Ii Kirpal Singh 9788180142512 , An Introduction To Mechanical Engine 4Ed Wickert Lewis 9789353507473 , Welding Engineering & Technology Parmar Bks53191 , Manufacturing Technology Vol 1-Foundry Forming Rao 9789353160500 , Manufacturing Technology Singh 9789381162385 , Dynamics Of Machines Balaguru 9789386668608 , Unconventional Machining Vivekanandhan Bks613041 , Basic Civil And Mechanical Engineering Shanmugam 9789355329547 , Engineerin Drawing 2Ed Shah / Rana 9788131710562 , Materials For Engineers And Technicians 7Ed Bolton 9781032973722 , Fuel Cell Technology Handbook Hoogers Bks333321 , Robots And Robotics Miller 9789387572966 , Non Destructive Testing And Materials Vivekanandhan Bks476859 , Engineering Mechanics Nelson 9780070146143 , Engineering Tribology 4Ed Stachowiak 9789351071679 , Materials Selection In Mechanical Design 5Ed Ashby 9789351073864 , Automobile Engineering Ayyappan Karthikeyan Bks464418 , Thermal Engineering Swaminathan Bks638475 , Automobile Engineering Babu Singh Bks587323 , A Textbook Of Production Technology Sharma Bks479783 , A Textbook Of Mechatronics Rajput Bks554009 , Automobile Engineering Jain 9780070445291 , Engineering Mechanics Statics & Dynamics Khanchani 9788180521089 , Basic Mechanical Engineering Prabhu 9788183715737 , Powder Metallurgy Ramakrisnan 9789381714485 , Additive Manufacturing Technology Hari Prasad 9789353500481 , Switching And Finite Automata Theory Jha 9780521176804 , Introduction To Mechanics 2Nd Ed Mahendra K Verma 9788173719813 , Basic And Applied Thermodynamics - A Ready Recknor Bhat 9789388005074 , Basic Refrigeration And Airconditioning 4Ed Ananthanarayanan 9781259062704 , Engineering Mechanics Applied Mecha Gupta 9789353505240 , Mechatronics Sathish Kumar Bks476759 , Automobile Engineereing Vol I Singh Bks247106 , Process Planning And Cost Estimating Selvakumar Bks480422 , Non Conventional Energy Resources Sawhney 9788120346093 , Non Conventional Energy Resources Sobh Nath Singh 9789332543577 , Introduction To Micromachining 2Ed Jain 9788184873610 , Vector Mechanics For Engineers Statics/Dynamics (Sie) Beer 9789353166625 , Fluid Mechanics &Hydraulics Rev &Updated Edn Ukarande 9789381162538 , Mechanical Measurements - Revision 6Ed Beckwith 9789353945633 , Vibration Monitoring Testing And Instrumentation C W.De Silva 9781032292137 , A Treatise On Turbomachines Gopalakrishnan Bks321517 , Construction Materials Vs Karthikeyan Bks476834 , Design Of Machine Elements Bhandari 9789390177479 , Mechanical Vibrations Bhava 9788131732489 , Design Of Transmission Systems Baskar Bks476758 , Engineering Materials And Metallurgy Baskar Bks638439 , Manufacturing Technology Vivekanandhan Bks638476 , Design Of Machine Elements Arunraja Bks638441 , Mechanical Vibrations Nag 9788126530908 , Power Plant Engineering Dhanasekar Bks505300 , Statistical Quality Control A Modern Introduction 6Ed Montgomery 9788126525065 , Additive Manufacturing Technologies Shiva Ahuj Shukla 9789357462419 , Hydraulics And Pneumatics Dixon Bks638479 , Engineering Principles Of Ground Modification Hausman 9789351341871 , Engineering Thermodynamics 6Ed Nag 9789352606429 , Refrigeration And Air Conditioning Arora 9789390385843 , Enterprise Resource Planning 4Th Edn Leon 9789353167820 , Foundations Of Material Science And Engg 6Th Edn Smith 9789355322173 , Shigleys Mechanical Engineering Design Budynas 9789390219636 , General Studies Paper - I ( 2025 ) Mhe 9789355327796 , Erp Demystified 3/Ed Leon 9789383286676 , Heat And Mass Transfer 6Ed Cengel 9789390185283 , Engineering Noise Control: Theory And Practices 4Ed Bies 9780415487078 , Rapid Prototyping And Engineering Applications Frank W.Liou 9781138569577 , Strength Of Materials Vol Ii Binu Sukumar 9789388005418 , Mechatronics A Foundation Course Clarence W.De Silva 9781138569553 , Design And Analysis Of Randomized Algorithms Hromkovic 9788132231592 , Metrology And Measurements Annamalai 9789388005463 , Fluid Mechanics And Machinery Molykutty 9789391549725 , Micro Electro Mechanical System Design Allen 9780824758240 , Micromachining Of Engineering Materials J Mcgeough 9781032419794 , Gas Turbine Combustion-3 Rd Ed Lefebvre 9781138569584 , Ergonomics Laboratory Exercises Joseph Gallwey 9781032973005 , Introduction To Biofuels Mousdale 9781439812075 , Environmental Engineering Charles Monteiro 9788119205509 , Power Plant Engineering Lijo Thomas 9788119365036 , Industrial Engineering Richard Carvalho 9788119205523 , Design & Operation Of Heat Exchanger Gerhard Rott 9788119365425 , Hydro Power Gerhard Rott 9788119205912 , Air Conditioning And Ventilation Systems Lijo Thomas 9788119365401 , Materials Science And Engineering Raghavan 9788120350922 , Automation And Collaborative Robotics (Dp) Mathews 9781484277102 , Design Management : Create, Develop And Lead Effective Design Teams Picchi 9781484283615 , Heat And Mass Transfer 2Ed Karwa 9789811926099 , Testing Of Metallic Materials 2Ed Suryanarayana 9788178001340 , Introduction To Engineering Materials 2/Ed Murray George 9781032530772 , Mechanics Of Composite Materials 2/Ed Jones R.M 9781138571075 , Reliability Evaluation Of Enginnering Systems 2Ed Billinton 9788181285522 , Workshop Practice Manual 6/Ed Reddy 9788178003078 , Finite Element Analysis 2D Lakshmi Narasai 9789389354225 , Engineering Mechanics Pb Lakshmi 9789390211609 , Engineering Mechanics 2Ed Harbola 9788131518298 , Environmental Science And Engineering Rajesh Gopinath 9789387511569 , Materials Science And Engineering Periodical Renewal Gilmore 9788131520451 , Environmental Science With Mt 16 Th Ed Miller 9789355738899 , Fluid Mechanics Munson Huebsch 9788126553433 , Engineering Mechanics: Dynamics, Si Version Meriam Bolton 9788126565375 , Engineering Mechanics Statics And Dynamcs James Meriam Kraige 9789354248566 , Engineering Fluid Mechanics Elger 9788126564491 , Engineering Mechanics Applied Mecha Gupta 9789353505240 , Machine Design Data Book Ramana 9789387593879 , Heat Transfer Alan 9789332575066 , Theory Of Machines 3Ed Bevan 9788131729656 , Introduction To Enviromental Engineering And Science Masters 9789332549760 , Heat And Mass Transfer Mayilsamy 9788131733837 , Engineering Thermodynamics 4Ed Rogers 9788131702062 , Operations Research :An Introduction-10Th Ed Hamdy Taha 9789352865277 , Engineering Mechanics - Statics & Dynamics Shames Rao 9788177581232 , Automation, Production Systems, And Computer - Integrated Manufacturing 5Th Ed Groover 9789361592959 , Introduction To Materials Science For Engineers 9E/D Shackelford 9789357059978 , Fundamentals Of Engineering Drawing Luzadder 9789332549982 , Engineering Materials Properties And Selection 9Ed Budinski Naraimhulu 9789332574045 , Thermodynamics Rajadurai Bks471287 , Environmental Science And Engineering Kaushik 9788122436471 , Engineering Optimization 4Ed Rao 9789395161800 , Cad/Cam/Cim 5Ed Radhakrishnan 9789395161855 , Finite Element Analysis With Ansys Workbench Tickoo 9789355513007 , Industrial Waste Management Mathankumar Bks480053 , Metrology And Measurements Vivekanandan Bks638442 , Finite Elements Analysis Baskar Bks534307 , Environmental And Agriculture Kavitha Bks638465 , Energy Materials Bandarenka A.S 9781032530789 , Digital Twin Ranjan Ganguli 9781032934198 , Industry 5.0 The Future Of The Industrial Economy Uthayan 9781032600130 , Quantum Computation Helmut Bez 9781032983738 , Wind Electrical Systems Bhadra, 9780195670936 , Metal Fatigue In Engineering Stephens 9788126539215 , Introduction To Industrial Internet Of Things And Industry 40 Sudip Misra 9781032146751 , Sustainable Manufacturing For Industry 4.0 Jayakrishna K. 9781032728728 , Reverse Supply Chains: Issues And Analysis Gupta S.M. 9781032729039 , Industry 5.0 The Future Of The Industrial Economy Uthayan 9781032600130 , Gas Turbine Heat Transfer Cooling Je-Chin Han, Sandip Dutta 9781439855683 , First Course In Aerial Robots And Drones (A) Bestaoui Sebbane 9781032963518 , Handbook Of Induction Heating Rudnev 9780824708481 , Fracture Mechanics (Forth Ed) T.L Anderson 9781032292120 , Fire Safety Engg Design Of Structures, 2Ed Purkiss 9788131220085 , Future Energy Improved Sustainable And Clean Opitons Letcjer 9788131220849 , Introduction To Finite Elements In Engineering 5/E Tirupathi 9781009461818 , Fundamentals Of Gas Dynamics Babu 9781910390009 , Fundamentals Of Propulsion Babu 9788180522529 , Engineering Metrology 3Rd Ed Narayana Bks396066 , Engineering Mechanics Kumaravelan Bks315205 , General Aptitude For Competitive Examinations Pattanaik Bks670722 , Dictionary Of Heat Power Engineering Ramalingam 9789386923035 , Environmental Pollution Principles Narayana Bks353570 , Production Processes Luqman 9788123918983 , Tractors And Their Power Units, Hb Lijiedahal 9788123905013 , Metal Cutting Principles Shaw 9788123901367 , Sheet Metal Press Tools Design And Making A Practical Approach Luqman 9788123925134 , Solid State Physics Wahab 9788184877786 , Practical Non - Destructive Testing, 3Ed Baldev Raj 9788173197970 , Mechanics Of Machines, 3Ed Ramamurti 9788173198922 , Handbook On Quality And Productivity Improvement Of Concrete Nayak 9788184876390 , Environmental Studies 4Ed Rajagopalan 9789354978944 , Finite Element Methods Dhanraj 9780198073901 , Fluid Dynamics Raisinghania Bks320511 , Entrepreneurship 11/Ed Hisrich 9789390113309 , Thermodynamics 9Th Ed Cengel 9789353165741 , Cad / Cam : Computer - Aided Design & Manufacturing Groover 9788177584165 , Engineering Vibration, 4/E Inman 9789332518483 , Thermodynamics 9Th Ed Cengel 9789353165741 , Schaums Outline Of Mechanical Vibration Graham Kelly 9789389538861 , Enterprise Resource Planning Singla 9789360531485 , Machine Drawing 51Ed Bhatt 9789385039560 , Heat Treatment : Principles And Techniques 3Ed Rajan 9788119364077 , Total Quality Management 2Ed Mukerjee 9788119364299 , Heat Treatment : Principles And Techniques 3Ed Rajan 9788119364077 , Operations Research Panneerselvam 9789354437892 , Design Thinking Teun Den Dekker 9781032786018 , Aeroplane Ramalingam 9788193103159 , Faqs In Control Systems Engineering Pattanaik 9789394639003 , Mass Transfer - Theory & Practice Begum/Anantharaman 9788120341692 , Total Quality Management 5Ed Besterfield 9789353066314 , Production &Operations Management 3Ed Panneerselvam Bks477079 , Manufacturing Technology Vol 2-Metal Cutting Rao 9789353160524 , Engineering Drawing Agrawal 9789353167448 , Cad / Cam : Computer - Aided Design & Manufacturing Groover 9788177584165 , Engineering Mechanics : Statics & Dynamics Kottiswaran Bks307984 , Power Plant Engineering Hegde 9789332534100 , Hydraulics And Fluid Mechanics Hydraulic Machine Modi , Seth Bks291963 , Fundamentals Of Heat And Mass Transer Kothandaraman Bks481435 , Alternative Fuels For Ic Engines Krishnasamy 9789364441995 , Mechatronics Electronic Control Systems In Mechanical And Electrical Eng Bolton 9789357052849 , Manufacturing Technology Vol 2-Metal Cutting Rao 9789353160524 , Fundamentals Of Heat And Mass Transer Kothandaraman Bks481435 , Mechatronics Electronic Control Systems In Mechanical And Electrical Eng Bolton 9789357052849 , Production &Operations Management 3Ed Panneerselvam Bks477079 , Engineering Drawing Agrawal 9789353167448 , Mass Transfer - Theory & Practice Begum/Anantharaman 9788120341692 , Industrial Robotics Control Frigeni 9781484294154 , Gate 2025 Production And Industrial Eng Gkp 9789356818170 , Engineering Vibration, 4/E Inman 9789332518483 , Fundamentals Of Engg Heat And Mass Transfer-5Ed Sachdeva 9789386070968 , Internet Of Nanothings And Wireless Body Area Networks Fadi 9781032599144 , Modern Machining Processes Pandey 9789386761835 , Materials Science For Mechanical Engineering Palanisamy 9789386923059 , Materials Science For Mechanical Engineering Palanisamy 9789386923059 , Textbook Of Fluid Dynamics Chorlton 9788123908816 , Engineering Mechanics : Statics & Dynamics Kottiswaran Bks307984 , Robotics Rajmohan Bks480419 , Hmt Data Book Kothandaraman 9788812243594 , Design Data (Data Book) Psg Bks58578 , Digital Signal Processing 2Ed Paulo Diniz 9781108406703 , 8086 Microprocessor And Applications 3Ed Kani 9789354661327 , Wireless Telecommunication System & Network Mullett 9788131520123 , Operational Amplifiers & Linear Integrated Circuits Lal Kishore 9788177585667 , Mobile Computing Principles Bfar 9780521696234 , Microprocessors & Programmed Logic 2Ed Short 9788131709160 , Design With Pic Microcontroller Peatman 9788177585513 , Digital Systems Design With Access Code Nagoor Kani 9789354667688 , Introduction To Biomems Folch 9781032568225 , Introduction To Biomedical Equipment Technology 4Ed Carr 9788177588835 , Antennas & Wave Propagation Raju 9788131701843 , Raspberry Pi For Dummies Cook 9789357460422 , Digital Signal Processors : Architectures --Op Kuo 9788131717936 , Principles Of Electromagnetics, 6Ed Sadiku 9780199461851 , Advanced Digital Design With The Verilog Michael.D.Ciletti 9789332584464 , Neural Networks Kumar 9781259006166 , Embedded System 2Nd Ed Peckol 9789357463966 , Microprocessor And Peripherals Chowdhury Bks405737 , Networks & Systems Roy Choudhury 9789389802535 , Microcontroller Theory And Application With The Pic Rafiquzzaman 9788126548354 , Digital Signal Processing For Anna University Kani 9789354661006 , Digital Signal Processing 3Ed Kani 9789354661167 , Analog And Pulse Circuits Lakshmaiah D 9789389354201 , Electronic Devices And Circuits Orient 9789386235305 , Quantum Chemistry 7 Ed Levine 9789332558533 , Engineering Circuit Analysis 9/Ed Hayt 9789390185139 , Gate 2025 Electronics And Communication Eng.Guide Gkp 9789356819306 , Chip Design For Submicron Vlsi : Cmos Layout And Simulation Uyemura 9788131501955 , Microelectronics Neamen 9789354601637 , Neural Networks And Learning Machines Haykin 9789332570313 , Electronic Circuits : Fundamentals And Applications 5Ed Tooley 9781032726687 , A Course In Digital Signal Processing Pucca Bundh Porat 9788126534913 , Signals And System Apte 9781316615393 , Digital Design 6Ed Mano 9789353062019 , Principles Of Signal Processing And Liner System Lathi 9780198062288 , Fiber Optic Communications 5Ed Palais 9788131717912 , Circuits And Networks Sudhakar 9789339219604 , Introduction To Communication Systems Madhow 9781316608241 , Analog Communication Rao 9780070704800 , Arduino Based Embedded Systems Singh 9781032964058 , Next Generation Wireless Lans 2Nd Ed Perahia 9781107414617 , Arm Microprocessor System Tahir 9781138387539 , Digital Communication Mutagi Bks478677 , Advanced Microprocessors & Peripherals Bhurchandi 9781259006135 , Vlsi Design Chitra 9788183716598 , Television And Video Engineering Salai Thillai 9788183712194 , The Design Of Cmos Radio Frequency Integrated Circuits Lee 9780521613897 , Network Security : Private Communication In A Public World Charlie Kaufman 9788196874339 , Sensors And Transducers Patranabis 9788120321984 , Neuro Fuzzy And Soft Computing Jang Sun Mizutani 9789332549883 , Network Analysis Channa Venkatesh 9788131533215 , Circuits Carlson 9788131505861 , Op Amps And Linear Integrated Circuits : Concepts And Applications Fiore 9788131512340 , Mobile Computing Principles Bfar 9780521696234 , Instrumental Methods Of Analysis Willard 9788123909431 , Vlsi Circuits And Embedded Systems Hasan Babu 9781032906003 , Computer Organization And Embedded System-6 Th Ed Hamacher 9789339218317 , Network Analysis And Synthesis, 2Ed Singh 9789353166724 , Handbook Of Biomedical Instrumentations Khandpur 9789355328021 , Security And Privacy In Internet Of Things Lots Hu Fei 9781032707150 , Television & Video Engineering Veeralakshmi 9789380156699 , Power Quality Sankaran 9781138569249 , Introduction To Microcontroller Programming For Power Electronic Control Applications Rossi 9781032972183 , Communications System Laboratory Preetham Kumar 9781138603288 , Digital Signal Processing And Its Applications Senthil Kumar 9788195268726 , Multimedia Enabled Sensors In Iot Fadi 9781032599205 , Novel Wearable Antennas For Communication And Medical System Albert Sabban 9781041049579 , Internet Of Things Using Single Board Computers : Principles Of Iot And Python Programming Kanagachidam Baresan 9781484299258 , Handbook Of Optical Communication Networks Ilyas 9781498798037 , Communications System Laboratory Preetham Kumar 9781138603288 , Digital Watermarking And Steganography 2Nd Edition Shih 9781032972121 , Propagation Handbook For Wireless Communication System Design Crane 9780849308208 , The Internet Of Things In The Cloud Honbo Zhou 9781498770354 , Arduino Based Embedded Systems Singh 9781032964058 , 5G Mobile Communications Concepts And Technologies Saad Asif 9781032663159 , Electronic Devices 10Ed Robert Floyd 9789354493935 , Semiconductor Physics And Devices, 3Ed Sze 9789354243226 , Digital Fundamentals 11Ed Floyd 9789332584600 , Electronic Devices And Circuits--11 Ed Boylestad Nashelsky 9789332542600 , The 8051 Microcontrollers & Embedded Systems 2Ed Mazidi 9788131710265 , A System C Primer 2Ed Bhasker 9788178001418 , Household Electricity And Appliances P.B Bhagava 9789390211265 , Image Processing Analysis And Mach Sonka 9789386858146 , Verilog Hdl 2Ed +Cd Palnitkar 9788177589184 , Modern Semiconductor Devices For Integration Hu 9788131730249 , Analog Integrated Circuit Design Isv 2Nd Ed Chan Carusone 9788126543939 , Textbook Of Digital Electronics Vasudevan 9789381714539 , Microwave Engineering 4Ed Das 9789390113347 , Analysis Of Microcontrollers For The Students Kothari 9789381714294 , Digital Signal Processing : For C.S.I.T Palani 9789380618388 , Fundamentals Of Digital Images Processing Jain 9789332551916 , Signals And Systems Sreenivasa Reddy 9789389354041 , Satellite Communications Pratt 9789354243035 , Analog Signals And Systems Kudeki 9788131787984 , Embedded Systems Handbook 2Ed System Design And Verification Zurawski Bks331222 , Vlsi Design And Eda Tools 2Nd Ed Sarkar 9788183714976 , Vlsi Design Das 9780198094869 , 8085 Microprocessor Pramod Borole 9789382127581 , Fundamentals Of Communication Systems Proakis 9788131705735 , Short Range Wireless Communication 3Ed Bensky 9789351073994 , Introduction To Fiber Optics Ghatak Ajoy 9781316644010 , The Definitive Guide To Arm Cortex M3 And Cortex M4 Processors Yiu 9789351071754 , Rf Circuit Design Ludwig 9788131762189 , Electric Circuits For Be/Betch 2Ed Kani 9789354663925 , Control Systems Nagoor Kani 9789389239010 , Digital Logic Circuits Nagoor Kani 9789354669989 , Microwave And Rf Design Steer 9789380381305 , Electrical Measurement And Measuring Instruments Rajput Bks543993 , Digital Signal Processing 3Ed Kani 9789354661167 , A Handson Course In Sensors Using The Arduino And Raspberry Pi Ziemann Volker 9781032791470 , Signal And Systems Simplified 2Ed Nagoor Kani 9789354661013 , Basic Electrical And Electronics Engineering 2/Ed Bhattacharya 9789332586505 , Ad Hoc Wireless Networks : Architectures & Protocols Murthy 9788131706886 , Ad Hoc And Wilreless Sensor Network Athawale 9789356066137 , Digital Circuits Design Kothari 9789332543539 , Solid State Electronic Devices Streetman 9789332555082 , Wireless Communication Goldsmith 9780521704168 , Probability And Stochastic Processes 3Ed Yates 9789354243455 , Signals, Systems And Inference Oppenheim 9789356064676 , Electromagnetic Field And Waves Salivahanan 9788119896677 , Analog Design For Cmos Vlsi Systems Maloberti 9788181284341 , Vlsi Design Michael 9780849318764 , Cognitive Sensors And Iot Fadi 9781032599236 , Digital Design & Computer Organization Farhat 9780849311918 , Digital Intergrated Circuits Evegni 9780849330575 , Introduction To Iot With Machine Learning And Image Processing Using Raspberry Pi Ambaji Kulkarni 9781032966885 , Basic Electrical And Electronics Engineering Murugan 9789384726072 , Adaptive Antenna Arrays Chandran 9788181289322 , Networks Lines & Fields 2Ed Ryder 9789332559516 , Data Compression : The Complete Reference Salomon 9788184898002 , Electric Circuits Bell Bks321194 , Digital Signal Processing Oppenheim 9789332550339 , Iot Standards With Blockchain : Enterprise Methodology For Internet Of Things Upadrista 9781484284278 , An In Depth Guide To Mobile Device Forensics Chuck Easttom 9781032785905 , Digital Signal Processing Oppenheim 9789332550339 , Digital Modulation & Coding Wilson 9788131721438 , Fundamentals Of Mobile Computing 2Ed Pattnaik Bks534717 , Introduction To Iot With Machine Learning And Image Processing Using Raspberry Pi Ambaji Kulkarni 9781032966885 , Biomedical Instrumentations And Measurements Cromwell 9789332556911 , Artificial Neural Networks For Engineers And Scientists Chakraverty S. 9781032729121 , Digital Communication Bhattacharya 9780070591172 , Signals And Systems 2/Ed Oppenheim 9789332550230 , Fundamentals Of Modern Vlsi Devices Yuan Taur 9781316649794 , Digital Systems:Principles&Design(Anna) Rajkamal 9789332535916 , Principles Of Cognitive Radio Vincent 9781107439900 , Digital Signal Processing 4Ed Proakis 9788131710005 , Op Amps And Linear Integrated Circuits Gayakwad 9789353949037 , Microwave And Radar Engineering Rao 9788131799444 , Introduction To Pspice Using Orcad For Circuits And Electronics Rashid 9789332555174 , Basic Electronics Saha 9781316632932 , Linear Integrated Circuits Salivahanan 9789353163808 , Principles Of Electronic Communication Orient 9789386235107 , Optoelectronic Devices And Optical Fiber Communication Chakrabarti 9789354667947 , Introduction To Vlsi Design Flow Sneh Saurabh 9781009200813 , Antennas And Wave Propagation Kraus 9789352606184 , Network Analysis Revised 3Ed Van Valkenburg/ Rathode 9789353433123 , Communication Systems : Analog And Digital, 3Rd Singh 9781259004605 , Internet Of Things The : How Smart Tvs Sm Miller 9789332552456 , Microwave Devices & Circuits 3Ed Liao 9788177583533 , Fundamentals Of Mobile Computing 2Ed Pattnaik Bks534717 , 5G Mobile And Wireless Communication Technology Pauline Cullen 9781009590921 , The Intel Microprocessors : 8086/8088,80186/80188,80286,80386,80486,Pentium, Pentium Pro Processor, Pentium Ii - 8Ed Brey 9788131726228 , Circuits Analysis Theory And Practic Robbins 9788131519028 , Medical Instrumentation 5Ed : Application And Design : An Indian Adaptation Webster 9789354249150 , Microwave Engineering, An Indian Adaptation Theory And Techniques Pozar 9789388991087 , Wireless Communications 2Ed Molisch 9789354248795 , Controll System Eng. 8/Ed Norman 9789357463980 , Signals, Systems, And Transforms, 4/E Phillips 9789332518490 , Antenna Theory And Applications 4Ed Balanis 9789354248474 , Gate 2025 Electronics And Communication Eng.Guide Gkp 9789356819306 , Introduction To Analog And Digital Communication 2Ed Haykin 9789354644337 , Digital Image Processing Gonzalez 9789353062989 , Power Electronics (An Indian Adaption) Ned Mohan 9789354640278 , Dorfs Introduction To Electric Circuits Wiley India Edition Richard 9788126573493 , Electronic Devices 10Ed Robert Floyd 9789354493935 , Communication Systems 5Ed Haykin 9789354640896 , Modern Control Engineering Ogata 9789332550162 , Electric Circuits With Mt Kang 9789386650344 , The Intel Microprocessors : 8086/8088,80186/80188,80286,80386,80486,Pentium, Pentium Pro Processor, Pentium Ii - 8Ed Brey 9788131726228 , Modern Digital Electronics-5Th Edtion Jain 9789355321770 , Analog And Digital Electronics Roth 9789353502355 , Introduction To Communication Systems Madhow 9781316608241 , Voip Handbook Application Technologies Ahson 9781420070200 , Embedded Systems Handbook 2Ed Network Embedded System Zurawski Bks331227 , Matlab: An Introduction With Applications 6Ed Amos Gilat 9789357462174 , Fiber Optic Communication Systems 5Ed Agrawal 9789357461245 , Crc Handbook Of Modern Telecommunications 2Ed Morreale Bks331221 , Mathematical Aspects Of Signal Processing Sircar 9781107175174 , Rf And Microwave Semiconductior Device Handbook Golio 9780849315626 , Electronic Systems Maintenance Handbook, Second Edi Whitaker Bks322864 , The 8051 Microcontroller Ayala 9788131502006 , Digital Systems Design Using Vhdl W/ Roth 9788131518304 , Fundamentals Of Engineering Electromagnetics Cheng 9789332535138 , Basic Electronics-2Ed Kothari 9789352606467 , Power Electronics Essentials & Applications Umanand 9788126519453 , An In Depth Guide To Mobile Device Forensics Chuck Easttom 9781032785905 , Automotive Embedded Systems Handbook Navet Bks335190 , Wavelet Analysis With Applications To Image Process Prasad 9780849331695 , Primer On Wavelets And Their Scintific Applications Walker 9781032963617 , Face Detectin And Recognition: Theory And Practice Datta A.K. 9781032728964 , Fiber Optics & Optoelectronics Khare 9780195669305 , Mobile Cellular Telecomm 2E Lee 9780070635999 , Cmos Vlsi Design : A Circuits And Systems Perspective, 3Ed Weste 9788131762653 , Antennas Blake 9789380381268 , Mobile Communications, 2Ed Schiller 9788131724262 , Introduction To Wireless Systems Black 9788131726389 , Ad Hoc And Wilreless Sensor Network Athawale 9789356066137 , Linear Integrated Circuits Sathishkumar Bks476847 , Linear Integrated Circuits Dhanasekar Bks638493 , Embedded And Real Time Systems Ramprabu Bks476848 , Transmission Lines And Rf Systems Shanmugaraja Sivakumar Bks490771 , Transmission And Distribution Gayathri Bks476751 , Wireless Communication Santhosh Krishna Bks638491 , Digital System Design Edwindhas Bks638462 , Power Quality & Distributed Generation Jayaprakash 9788184876987 , Digital Signal Processing Antoniou 9780070636330 , Power System Engineering 3 Ed Kothari 9789353165116 , Digital Integrated Circuit 2/Ed Rabeay 9789332573925 , Principles Of Electronic Materials Kasap 9789390113866 , Digital Logic Circuits With Vhdl And Verilog Programs Nagoor Kani 9789354669606 , Principles Of Electronic Materials Kasap 9789390113866 , Wireless Communications : Principles Rappaport 9789356066212 , Communication Networks Fundamentals Leon 9780070595019 , Interoperability In Iot For Smart Systems Roy M. 9781032728100 , Basic Elec & Linear Circuits Bhargava 9781259006463 , Brain Computer Interface Eeg Signal Processing Panigrahi 9781032851181 , Learning Basics And Electronic Science Through Mcqs Priya 9789394639249 , Fundamentals Of Logic Design Roth 9789360535650 , Engineering Circuit Analysis 10E/D Hayt 9789364441094 , Programmable Logic Controllers 6Th Ed Petruzella 9789355325860 , Modern Wireless Communication Haykin 9788131704431 , Signals And Systems 5Ed Ramesh Babu Bks505218 , Digital Signal Processing Ramesh Babu Bks503977 , Digital Image Processing 2Ed Sridhar Bks643706 , Digital Logic Circuits With Vhdl And Verilog Programs Nagoor Kani 9789354669606 , Wireless Communications : Principles Rappaport 9789356066212 , Digital Integrated Circuit 2/Ed Rabeay 9789332573925 , Brain Computer Interface Eeg Signal Processing Panigrahi 9781032851181 , Internet Of Nanothings And Wireless Body Area Networks Fadi 9781032599144 , Phyiscs For Electronics & Information Science Palanisamy 9789386923134 , Vlsi Design Sathyah Bks665018 , Basic Elec & Linear Circuits Bhargava 9781259006463 , Communication Networks Fundamentals Leon 9780070595019 , Linear Integrated Circuits Salivahanan 9789353160487 , Wireless Communications : Principles Rappaport 9789356066212 , Linear Integrated Circuits Salivahanan 9789353160487 , Digital Logic & Computer Design Mano 9789332542525 , Digital Electronics Bignell 9788131520710 , Design Of Analog Cmos Integrated Circuit-2Ed Razavi 9789387067844 , Fundamentals Of Logic Design Roth 9789360535650 , Engineering Circuit Analysis 10E/D Hayt 9789364441094 , Digital Electronics Bignell 9788131520710 , Design Of Analog Cmos Integrated Circuit-2Ed Razavi 9789387067844 , Applied Machine Learning Gopal 9789354601590 , Essentials Of Digital Signal Process Using Matlab Ingle/Proakis 9788131517727 , Arm System On Chip Architecture Furber 9789332555570 , Smart Grid In Iot Enabled Spaces Fadi Ai Turjman 9781032598543 , Power Plant Engineering Nag 9789354600050 , Mathematical Analysis A Straightforward Binmore 9781107526235 , Algebra 2Nd Edition Michael Artin 9789353432751 , Discrete Mathematics Dhami 9780199452798 , Statistics And Numerical Methods 10Ed Vijayakumari 9789356062733 , Algebra, 3Ed Sahai 9788173198250 , Algebraic Topology M J Greenberg , J R Harper 9780367475604 , Algebra, 4Ed Sahai 9788184876208 , Concept Of Modern Algebra Pandey 9788184877069 , Friendly Introduction To Number Theory Silverman 9789353433079 , Elementary Differential Equations 8Ed Richard 9789332571617 , Introduction To Graph Theory West 9789332549654 , Linear Algebra Ubaidullah 9789391549893 , Higher Algebra Barnard 9789385923326 , Sequences And Series Arumugam 9789388005128 , Modern Analysis Arumugam 9789388005111 , Intorduction Topology And Modern Analysis Simmons 9789387465916 , Higher Algebra Hall Knight 9788174731043 , Analytical Geometry Veerarajan 9789388005142 , Transforms And Partial Diffrential Equations 3Rd Ed Muthucumaraswamy 9789391549473 , Multilevel Analysis: Techniques And Applications 3/E Hox 9781032938035 , Thomas Calculus 15Ed Hass 9788119896608 , Calculus Vil I 2Ed ( An Indian Adaptation) Apostol 9789354642630 , Calculus 10Ed Saturmino Salas Einar Hille Ga 9789390421961 , Introduction To Linear Regresion Analysis, 6Ed Montgomery 9789357461283 , Matrices Advanced Calculus & Complex Stewart 9789360534509 , Operations Research Mote 9788126556380 , Topology 2Ed James Munkres 9789353432775 , Linear Algebra 5Ed Friedberg 9789390168132 , Multivariate Calculus Joshi Bks498996 , Mathematical Analysis 6Ed Malik Bks413195 , Stochastic Processes 5Ed Medhi 9789389802245 , Human Resource Management Aswathappa 9789355323675 , The Elements Of Complex Analysis 3Ed Choudhary 9789388818780 , Probability And Statistics For Engineering Devore 9789353506247 , Operations Research Panneerselvam 9789354437892 , The Elements Of Complex Analysis 3Ed Choudhary 9789388818780 , Optics 8Ed Ghatak 9789355328595 , Outline Of Beginning Physics Schaum 9789389538984 , Outline Of Astronomy Schaum 9789389538939 , Introductory Nuclear Physics 3/Ed Krane 9789354640834 , Physics Vol 2 5Ed David Halliday Resnick 9789354640438 , Physics For Scientists And Engineers Serway 9789355739223 , Non Conventional Energy Source Math 9789388005081 , Nuclear Physics Theory And Experiments 3Ed Roy 9788122449884 , Gravitation : Foundations And Frontiers (South Asian Edition) Padmanabhan 9780521178761 , Electricity And Magnetism Murugeshan 9789352837342 , Introductory Nuclear Physics Wong 9788126546060 , Modern Physics Murugeshan Bks367126 , Introduction To Electrodynamics South Asia Ed - 4/Ed David J. Griffiths 9781108822909 , Theoretical Astrophysics Vol 2 Padmanabhan 9781107400603 , Heat Thermodynamics And Statistical Physics Lal Subramanian Bks460942 , Classical Dynamic Of Particles Thornton 9788131518472 , Materials For Engineers And Technicians 7Ed Bolton 9781032973722 , Statistical Mechanics 2Ed (An Indian Adaption) Kerson Huang 9789354247736 , Atomic And Molecular Spectroscopy Rita Kakkar 9781108413206 , Laser Fundamentals Silfvast 9780521138475 , Engineering Chemistry 2E : Fundamentals And Applications Shikha Agarwal 9781108724449 , Organic Name Reations Sanjay Bari 9789389354737 , Basics Of Environmental Science Khosla 9788184874013 , Environmental Chemistry Singhu 9788122427318 , Biomaterials Principles And Applications Joon Park 9781032934167 , Organic Reaction Mechanisms Ahluwalia Bks366263 , Organic Synthesis Concepts And Methods 3Ed Pb 2014 Jurgen Hinri 9788126547227 , Engineering Chemistry Palanna 9789352605774 , Engineering Chemistry 2Nd Ed Wiley 9788126543205 , A Textbook Of Engineering Chemistry Dara Bks561640 , Engineering Chemistry Vairam & Kalyani 9788126543342 , Chemical Applications Of Group Theory Albert Cotton 9788194726364 , Environmental Science And Engineering Yuganath 9788183717014 , Environmental Science Isv 8Th/Ed Botkin, Killer 9788126534142 , Chemical Reaction Engineering 3Ed (An Indian Adaptation) Octave Levenspiel 9789354244605 , Outline Of Thermodynamics Schaum 9789389538540 , Textbook Of Chemical Engineering Thermodynamics Narayanan 9788120347472 , Communication Skills, 3Ed Sanjay Kumar 9789354978555 , English For Science & Technology-I Chellammal 9781009224796 , English For Science & Technology-Ii Francis 9781009251181 , Effective Technical Communication Rizvi 9789352605781 , Research Methodology Vinod 9789352863518 , Placement Interviews Skills For Success Anandamurugan 9780070700956 , Prowess Orient 9789354421242 , Research Methodology Panneerselvam 9788120349469 , Academic Writing A Handbook For Students Stephen Bailey 9781138615533 , Design Thinking In Technical Communication Jason C K Tham 9781041004356 , Principles Of Scientific And Technical Mohapatra 9789355327482 , Critical Thinking Idea Innovation And Creativity Richard H Mccuen 9781041000846 , Literature For Language Skills 2Ed Mahanand 9789388005470 , Academic Writing P.B Ajay Semalty 9789390211739 , Teaching English Through Folktales Mahanand 9789391549077 , An Introduction To Literary Studies Mario Klarer 9781032785974 , Heritage Of Tamils Muthuramalingam 9789391549718 , A Short History Of English Literature Saintsbury 9788174733054 , The English Language Wrenn 9788174733368 , An Introduction To The Study Of English Litetrature Hudson 9788174731197 , Rabindranath Tagores Ideational Challenges Bidyut Chakrabarty 9789356400122 , English Literature Long Bks476291 , Test Of Reasoning 7Th Edn Thorpe 9789389811513 , Science And Technology 8Ed Agarahri Ravi 9789355326324 , Excel Reasoning Arun Sharma 9789355329455 , Aptipedia Aptitude Encyclopedia 2 Ed Wiley 9788126569502 , Excel Quantitative Apititude Arun Sharma 9789355327970 , Verbal Ability And Reasoning For Competitive Examinations Anand Lalit Singh 9788126554294 , Intermediate Engligh Grammer With Answers, 2Ed Murphy 9788185618517 , Design Thinking Teun Den Dekker 9781032786018 , Spotting Errors Lakshminarayanan Bks670723
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
7.
Housing Urban and Rular Development #11221881 AOC
Tender For Providing Kitchen Equipment And Tv Sets In The Honble Ministers Residence Of Gb Dnyaneshwari At Malbar Hill, Mumbai.-1 . 50.00 Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit 2 . 125.00 Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON. 3 . 100.00 Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. 4 . 10.00 Supplying and erecting 5m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. 5 . 700.00 Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC 6 . 1.00 Supplying, fixing, and configuring 8-ports 1 G unmanaged gigabit POE switch erected in provided rack complete. 7 . 2.00 Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK 8 . 6.00 Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. 9 . 6.00 Supplying, installing, testing & commissioning of High definition 4 Megapixel IP IR Bullet Camera with following features Image Sensor: minimum 1/ 2.8 Progressive Scan CMOS, Video Resolution: minimum 2592x1520 Video compression: H.264, H.265 or higher, at least Three individually configurable stream, Frame Rate: minimum 25 fps at all resolutions. WDR: minimum 120dB Wide Dynamic Range, ON VIF profile conformant, minimum IR distance: 50m, Lens Type: 2.8-3mm Lens, auto/motorised varifocal, Field of View: horizontal FOV 103° to 32°, vertical FOV 73 ° to 24°, diagonal FOV 142 ° to 40 ° Lux sensitivityminimum 0.2 Luxatcolor, minimum 0.05 Luxat Black & White, 0.0 Lux (IR) Night Vision Distance Min IR- 50m, Camera minimum Adjustment Angles- Pan:350°, Tilt:72°, Rotate:350°. Power Supply: Support 12VDC & PoE, IP67, IK10 – Vandal Resistant, builtin microSD/ SDHC / SDX cards up to 128GB, builtin microphone. minimum Input / Output-Audioin×1 Audio Out × 1 , Alarmin × 1 ,Alarm Ou t× 1. Image Settings: Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements: Day/ Night-Auto (ICR)/Colour/ Black & White, 3D DigitalNoise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. Events: Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Regionentrance detection, Regionexiting detection. Operating temperature (-30to60°C). Security- User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES-256, SSH/Telnet closed, FTP disabled. Protocol-HCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/ ENO Requivalent BIS/TECH/STQ Corany indian standards as applicable, CE, FCC certified. duly erectedin position on wall/ceiling/false ceiling/ providedpole (mounting height not more than 5 meter)etc, with all accessorie sets complete. 10. 9.00 Supplying, installing, testing & commissioning of IP Fix Dome cameras High definition 4/5 Megapixel IP IR Dome Camera with following features Image Sensor: minimum 1/2.8 Progressive Scan CMOS, Video Resolution: minimum 2592 x 1520 Video Compression: H.264, H.265 or higher, at least Three individually configurable stream, Frame rate: minimum 25 fps at all resolutions, WDR: minimum 120 Db Wide Dynamic Range, ONVIF profile conformant, minimum IR distance: 40m, Lens Type: 2.8/4/6 mm Lens, fixed focal, Field of View: 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 40m Power Supply: Support 12VDC & PoE, - IP67 IK10, Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. Minimum Input /Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings: Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements: Day/Night-Auto (ICR)/Colour/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. Events: Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature (- 30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES-256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure Shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS /TECH/STQC or any indian standards as applicable, CE, FCC certified. Duly erected in position on wall/ ceiling /false ceiling/provided pole (mounting height not more than 5 meters), 11. 1.00 Supplying, installing, testing & commissioning of 32/4 0 Ch Network Video Recorder (NVR), suitable connect Min. 32 IP Cameras, up to 5 Megapixel Resolution, with HDMI 1/ VGA 1 out puts, provided Atleastone HDMI output of 4K resolution, atleastone VGA output with output up to 1920x1080, Support H.265 or higher, H.264, MJPEG, Supports Redundant Dual Power, Incoming Bandwidth 320 Mbps with minimum 8 SATA ports, ANR Technology, 8 SATA inter faces for 8HDD sand capacity of each HDD up to 8TB, minimum 02 USB port, AlarmI /O16/4, RJ-45, 10/100/1000Mbps self-adaptive Ethernet interface, support multi brand network Cameras, ON VIF conformance, Multiple network monitoring: Web viewer. support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS. RoHS, UL, CE, FCC certified. duly erected in the provided URack with wiring connections, tagging and programming, etc., complete 12. 1.00 Supplying, installing, testing & commissioning of 24 ports, POE switch in the provided rack as per specification No. WG- NWC/ENS 13. 2.00 Supplying, installing, testing & commissioning of 8TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6GB/S, maximum sustained transfer rate 210MB/Sector 213 MB/S. Drive bay supported 08+, Cameras supported up to 64, Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position, provided NVR 14. 1.00 Supplying, installing, testing & commissioning (SITC) of (32 inches) 4K Ulatra HD Mini LED AI Smart Neo-QLED TV (CArbon Silver) Resolution:4K Ultra HD (3840 x 2160) Resolution Refresh Rate: 100 Hz (Up to 144 Hz) Connectivity; 4 HDMI Ports For Seamless Connectivity With External Devices 2 x USB-A USB Port To Connect Hard Drives Or Other USB Devices Wi-Fi, Bluetooth, Anynet+ ( HDMI-CEC) Ethernet (Lan) Port Digital Audio Out (Optical), RF In (Terrestrial/ Cable Input/ Satellite Input) Sound:60W Output-4.2.2CH, Powerful Speakers with Dolby Atmos, Q-Symphony, Active Voice Amplifier Pro, 360 Audio Smart TV Features: Bixby, Far-Field Voice Interaction, Web Browser, SamrtThings Hub/ Matter Hub/Iot-Sensor Funtionality Apple AirPlay, Daily+Display: NQ4 AI Gen2 Processor, Neo Quantum, HDR+, HDR 10+, Auto HDR Remasatering, Quantum Matrix Technology, Ultra Viewing Angle, Ultimate UHD Dimming, Real Depth Enhancer Professional, AK AL Unscaling, HDR BrigthnessOntimizer Filmmaker Mode 15. 1.00 Supplying, installing, testing & commissioning (SITC) of 163cm (65 inches) 4K Ulatra HD Mini LED AI Smart Neo-QLED TV (CArbon Silver) Resolution:4K Ultra HD (3840 x 2160) Resolution Refresh Rate: 100 Hz (Up to 144 Hz) Connectivity; 4 HDMI Ports For Seamless Connectivity With External Devices 2 x USB-A USB Port To Connect Hard Drives Or Other USB Devices Wi-Fi, Bluetooth, Anynet+ ( HDMI-CEC) Ethernet (Lan) Port Digital Audio Out (Optical), RF In (Terrestrial/ Cable Input/ Satellite Input) Sound:60W Output-4.2.2CH, Powerful Speakers with Dolby Atmos, Q-Symphony, Active Voice Amplifier Pro, 360 Audio Smart TV Features: Bixby, Far-Field Voice Interaction, Web Browser, SamrtThings Hub/ Matter Hub/Iot-Sensor Funtionality Apple AirPlay, Daily+Display: NQ4 AI Gen2 Processor, Neo Quantum, HDR+, HDR 10+, Auto HDR Remasatering, Quantum Matrix Technology, Ultra Viewing Angle, Ultimate UHD Dimming, Real Depth Enhancer Professional, AK AL Unscaling, HDR BrigthnessOntimizer Filmmaker Mode 16. 2.00 Supplying, installing, testing & commissioning (SITC) of (75 inches) 4K Ulatra HD Mini LED AI Smart Neo-QLED TV (CArbon Silver) Resolution:4K Ultra HD (3840 x 2160) Resolution Refresh Rate: 100 Hz (Up to 144 Hz) Connectivity; 4 HDMI Ports For Seamless Connectivity With External Devices 2 x USB-A USB Port To Connect Hard Drives Or Other USB Devices Wi-Fi, Bluetooth, Anynet+ ( HDMI-CEC) Ethernet (Lan) Port Digital Audio Out (Optical), RF In (Terrestrial/ Cable Input/ Satellite Input) Sound:60W Output-4.2.2CH, Powerful Speakers with Dolby Atmos, Q-Symphony, Active Voice Amplifier Pro, 360 Audio Smart TV Features: Bixby, Far-Field Voice Interaction, Web Browser, SamrtThings Hub/ Matter Hub/Iot-Sensor Funtionality Apple AirPlay, Daily+Display: NQ4 AI Gen2 Processor, Neo Quantum, HDR+, HDR 10+, Auto HDR Remasatering, Quantum Matrix Technology, Ultra Viewing Angle, Ultimate UHD Dimming, Real Depth Enhancer Professional, AK AL Unscaling, HDR BrigthnessOntimizer Filmmaker Mode 17. 2.00 Supplying, installing, testing & commissioning (SITC) of (86 inches) 4K Ulatra HD Mini LED AI Smart Neo-QLED TV (CArbon Silver) Resolution:4K Ultra HD (3840 x 2160) Resolution Refresh Rate: 100 Hz (Up to 144 Hz) Connectivity; 4 HDMI Ports For Seamless Connectivity With External Devices 2 x USB-A USB Port To Connect Hard Drives Or Other USB Devices Wi-Fi, Bluetooth, Anynet+ ( HDMI-CEC) Ethernet (Lan) Port Digital Audio Out (Optical), RF In (Terrestrial/ Cable Input/ Satellite Input) Sound:60W Output-4.2.2CH, Powerful Speakers with Dolby Atmos, Q-Symphony, Active Voice Amplifier Pro, 360 Audio Smart TV Features: Bixby, Far-Field Voice Interaction, Web Browser, SamrtThings Hub/ Matter Hub/Iot-Sensor Funtionality Apple AirPlay, Daily+Display: NQ4 AI Gen2 Processor, Neo Quantum, HDR+, HDR 10+, Auto HDR Remasatering, Quantum Matrix Technology, Ultra Viewing Angle, Ultimate UHD Dimming, Real Depth Enhancer Professional, AK AL Unscaling, HDR BrigthnessOntimizer Filmmaker Mode 18. 2.00 Supply, Installation, Testing and commissioning (SITC) of Cooktop with Double Drip Tray, Auto Ignition, Toughened Glass, Ultra Slim Frame, Bakelite Knobs 19. 1.00 Supply, Installation, Testing and commissioning (SITC) of 60 Litres Oven Toaster Grillers with Glass Door, 2000W Heating Element, Stainless Steel Body 20. 1.00 Supply, Installation, Testing and commissioning (SITC) of Automatic Coffee Machine with Milk frothing system of 600ml capacity, Push to Operate, Cofee types Espresso, Cappuccino, Latte, Water tank capacity of 1.5 Litre, Pump pressure of 15 Bar, Thermoblock heating system, Power 1250W, Voltage 220 – 240V with accesories. 21. 1.00 Supply, Installation, Testing and commissioning (SITC) of 1000 Watt 4 Jars Black Mixer Grinder with 5 Preset Modes with RPM blender 20000 rpm, Power 1000 W, ROHS compliant 22. 1.00 Supply, Installation, Testing and commissioning (SITC) of Juicer 800 Watts with Feeding Tube Size of 75 mm, Jar Capacity 800 ml, Cord length 1m, Power 800 W, Voltage 220 - 240 V 23. 1.00 Supply, Installation, Testing and commissioning (SITC) of 60cm 1500m3/hr Ducted Wall Mounted Chimney with LED Lamp, Suitable for 2-4 Burners, Filter Type: Filterless, Suction Power: 1500 m3/hr Mount Type: Wall Mount, 24. 2.00 Supply, Installation, Testing and commissioning (SITC) of Double Door Frost Free Refrigerator with 428 Litres Capacity, Double Door Refrigerator, Frost Free Refrigerator, Easy Fresh Technology, Duo Cool Technology, Easy fresh compartment-2N, Touch panel, Hot to Cool Next Gen 8-step inverter compressor, Duo cooling technology, Vario safe, Spice box, Vegetable sorting system, Flip box, Ice Cream box, Fresh box 25. 1.00 Supply, Installation, Testing and commissioning (SITC) of 680 Litres Frost Free French Door Refrigerator with Water Dispenser 26. 1.00 Supply, Installation, Testing and commissioning (SITC) of Dryer Refresher with 9.0/6.0/3.0 Kg Capacity, 1400 RPM, 7 Segment LED display, Touch Control with Knob, Steam, Spin Speed of 1400, Anticrease, Prewash, Soak, Extra Rinse, Rinse Hold, Time Saver features. 27. 2.00 Supplying, installing, testing & commissioning (SITC) of (43inches) 4K Ulatra HD Mini LED Smart TV Resolution:4K Ultra HD (3840 x 2160) Resolution Refresh Rate: 100 Hz (Up to 144 Hz) Connectivity; 4 HDMI Ports For Seamless Connectivity With External Devices 2 x USB-A USB Port To Connect Hard Drives Or Other USB Devices Wi-Fi, Bluetooth, Anynet+ ( HDMICEC) Ethernet (Lan) Port Digital Audio Out (Optical), RF In (Terrestrial/ Cable Input/ Satellite Input) Sound:60W Output- 4.2.2CH, Powerful Speakers with Dolby Atmos, Q-Symphony, Active Voice Amplifier Pro, 360 Audio Smart TV Features: Bixby, Far-Field Voice Interaction, Web Browser, SamrtThings Hub/ Matter Hub/Iot-Sensor Funtionality Apple AirPlay, Daily+Display: NQ4 AI Gen2 Processor, Neo Quantum, HDR+, HDR 10+, Auto HDR Remasatering, Quantum Matrix Technology, Ultra Viewing Angle, Ultimate UHD Dimming, Real Depth Enhancer Professional, AK AL Unscaling, HDR BrigthnessOntimizer Filmmaker Mode
Contract Date: Sep 23, 2025 Contract Value : 37.85 Lakh
Government Departments No of Bidders 2
Maharashtra View Result →
8.
Educational and Research Institute #11203813 Technical Bid
Tender For Selection Of System Integrator For Supply, Establishment, Operation And Maintenance Of Center Of Excellence On Digitalization Through Simulation At Government College Of Engineering, ,Amravati - Hardware Part , Battery Charge And Discharge Test System , Data Acquisition And Logging System , Thermocouple Rtd For Temperature Measurement , Battery Tester For Internal Resistance Testing , Electric Vehicle Bldc Motor Training System , Bldc Brushless Inner Rotor Brushless Dc Motor Coupled , Battery Characteristics Training System , Pmdc Motor Training System , Power And Transmission System Study Models For Ev Application , Pmsm Motor Coupled With Dc Generator Test Bench Setup , Switched Reluctance Motor Coupled , Pwm Charge Controller Training System , Sectioned Electric Vehicle Twowheeler Chassis , Sectioned Electric Vehicle Fourwheeler Chassis , Battery Resistance Spot Welding Machine , Dc Ac Clamp Meter , Noncontact Type Tacho Meter , Computing Workstations For Ev Design And Simulation , Multibody Dynamics Analysis Research Software Bundle For Ev 10 User , Power Train Gearbox Design Research Software Package , 1D3d Thermal Modelling Bms Modelling Electric Motor Ic Engine , Multiphysics Cae Research Software Package , Nmc Cell Size 18650 , Nmc Cell Size 26650 , Lfp Cell , Smart Bms Training System , Electric Vehicle Scanner , Diy Kits For 20 Students , Advanced Driver Assisting System Adas Training System For Emobility , Ac Ev Charger 10Kw , Dc Fast Charger 20Kw , Multifunction Installation Tester , Electric Vehicle Service Equipment Test Adapter Kit , Battery Tester With Inbuilt Printer , Digital Infrared Thermometer , Digital Multifunction Meter With Vfd Efdetection 3Phase Rotation , Vde Approved Insulated Tool Set For Ev , Electric Vehicle Safety Equipment , Ev Battery Assembly Testing Centre Setup , Ev Battery Pack Cell Equalizer , Regenerative Charging And Braking Training System , Ev Assembly Disassembly Kit , Three Phase Power Clampon Meter With Harmonics Measurement , Digital Insulation Multi Function Meter , Phase Sequence Indicator , Battery Quality Anaylyzer With Data Logger , Hybrid Display Module , Hybrid Trainer Module Motorized , Professional Wall Charts Approx 4 Ft 3 Ft , Professional Lab Layout And Design , Engineering Simulation Software Multiphysics Cae Research Software Includes Preprocessor And Post Processor 10 Users , 3D Cad Package 60 User , Professional Wall Charts , Professional Lab Layout And Design , Video Conferencing Setup , Electromagnetic Em Simulation , Integrated Circuit Ic Design Verification Academic Research Software , Soc Development Board With Software , Emcemi Test Equipment , Spectro Radiometer For Measurement Of The Luminous Flux Spectrum Color , 3D Printer For Prototyping , Professional Wall Charts Approx , Professional Lab Layout And Design , Revolving Chair With Arm Centre Pivot Mechanism , Computer Table , White Board With Stand , Revolving Office Chair With Arm Centre Pivot Mechanism For Faculty , Laboratory Wooden Table , Office Table For Faculty , Major Almirah With Glass Type Doors , Seminar Chairs With Desklet , Executive Office Table , Executive Office Chair , Sofa Set 321 Seater , Teapoycoffee Table , Visitors Chairs With Cushion , Major Almirah , Multi Function All In One Printer For Office And Lab , Necessary Electrification And Networking , Matting Area With Labour Work In Sq Ft , False Ceiling In Sq Ft , Window Sliding Door In Sq Ft , Window Curtains With Fitting In Sq Ft , Gypsum Plaster With Wall Putty In Sq Ft , Wall Coloring In Sq Ft , Air Conditioner 2 Ton , Cctv Camera , Interactive Board , Partitions Cubicles In Sq Ft , Training Support Part , Centre Incharge (Annual Cost) , Lab Operator (Annual Cost) Ev Lab , Faculty Training Ev Lab , Lab Operator (Annual Cost) Simulation Lab , Faculty Training Simulation Lab , Lab Operator (Annual Cost) Esdm Lab , Faculty Training Esdm Lab
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Maharashtra View Result →
9.
Public Administrative Department #11047153 Technical Bid
Tender For Re-Tender Purchase Tools, Equipment And Instrument For Industrial Training Institute (As Per New Syllabus -All Trade) , Ac Alternator Slip Ring Puller Specification - Variable Make - Appex / Mahesh / Meco , Air Blow Gun With Standard Accessories Specification - Standard Make - Super Hydro Pneumatic / Royal Sindicate Magipack Automation / Air Max , Air Impact Wrench With Standard Accessories Specification - Standard Make - Prime Tools India Ruchak Enterprises Hi - Tech Pnevmatics , Air Ratchet With Standard Accessories Specification - Standard Make - Stanley Ingersol Rand, Enakshi , Anti-Spatter Spray Can Specification - 100 To 300 Ml Make - Esab / Aerosol / Maay/ Jois Suns , C Clamps ,Mild Steel Specification - 50 Mm Make - Taparia / Sagar / Samrat / Powertex , C Clamps Specification - 100Mm Make - Taparia / Sagar / Samrat / Powertax , C Clamps Specification - 150 Mm Make - Taparia / Sagar / Samrat / Powertax , C.I. Sluice / Gate Valve (Flanged Type) Specification - 150Nb Make - L&T / Amco / Amtrch / Delisha Engg / Mnc , Chaser Hard W/V 9 To 40 T.P.I. Set Of 11 Internal. Specification - 9 To 40 Tpi Make - Super Threading Ind.Porttd / Dic Tools Well Cut Tools / Surya Engg , Chaser Hard W/V 9 To 40 T.P.I. Set Of 11External. Specification - 9 To 40 Tpi Make - Well Cut Tools /Surya Engg /Super Threanding / Dic Tools , Chipping Hammer With Metal Handle Specification - 250 Grams Make - Supra / Abm Tools / B R Kumar , Chisel Firmer With Wooden Handle Specification - 6 Mm X 200Mm Make - Bgi Tools / Taparia / Abm Tools / B R Kumar / Supra , Combination Drill / Centre Drill Specification - A3,A4 & A5 Make - Addison/ It / Sandvik / Dic Tools / Vega Tools / Nd Tools / Uncut Tools , Connecting Rod Alignment Fixture 1 Specification - Standard Size Make - Siddheshwar Engg / Gbb Industries / Max Preci Machine Pvt Ltd / Trinity India Forge Tech Pvt. Ltd. , Crimping Tool Set Hydraulic Specification - 16 Sq. Mm To 95 Sq. Mm Make - Taparia / Sagar / Samrat / Indigrust Yok -300 , Crimping Tool Specification - Dia Range 1.5 Sq. Mm To 16 Sq. Mm Make - Taparia / Jain Son/Lenden Hydrolic , Cylindrical Milling Cutter Specification - Ø 63 X 70 X Ø 27 Mm Make - Addison/ It / Sandvik / Globlehunt Engg / Expert Tool Indu , Dovetail Cutter Specification - Dia 20 X 8 Mm Shank X 60° Make - Addison/ It / Sandvik /Micro Sharp / Adroit Tooling / Shree Tools , Drift Punch Copper Specification - 10 X 15 1/2 Mm Make - Taparia / Sagar / Samrat / Bgi Tools / Parwa Metal Tech , Drill Angle Gauge Specification - 45,60,90 Make - Metrix Plus / Precise Gauges Mikronix Associates / Kristeel , Drill Chuck Specification - 13 Mm Capacity With Key & Arbour Mt- 3 Make - Balaji Engg /East Man Cost & Forge / Kta/ Sagar , Drill Chuck Taper Shank Specification - 16 Mm Capacity Make - Siddhi Preision Pvt Ltd /Trigon Enterprises / Taj Enterprises / Kta / Sagar / Sanou/ Rr/ Saifro , Drill Drift Specification - 200 Mm Hardened And Black Finish Make - Abm Tools Alok Tools / Precision Drill Draft , Drill Hand Brace Specification - 0 To 10 Mm Make - Bone Drills Bgi Tools / Akshar Industries , Drill Point Angle Gauge Specification - Standard Make - Mitutoyo /Bgi Tools / Abm Tools / Kristeel , Drill Twist Taper Shank H.S.S Specification - 8 Mm To 20Mm By 0.5Mm H.S.S. Make - Addison/ It / Sandvik/ Bgi / Indeavour Technologies , Earth Clamp Specification - 600A Make - Esab / Shree Shakti Industries /Hero Industries , Electrician Helmet Specification - Yellow Colour Make - Frp Shock Proof Tata / Hepro / Hooneywell Pvt Electrical , Equal Angle Cutter Specification - Ø 75X 30 X Ø 27 - 90° Make - Addison / It / Sandvik / C R Tools / Dic Tools / Maglix Tools , Feeler Gauge Specification - 20 Blades (Metric) Make - Sadguru Enterprises Bombay Tools / Perfect Gauge & Tools / Mitutoyo / Nigaka Seiki (Sk) , Filler Gauge Specification - 0.05 Mm - 1 Mm Make - Sadguru Enterprises Bombay Tools / Perfect Gauge & Tools / Mitutoyo , Flat Tongs Specification - 350 Mm Long Make - Bgi Tools / Sudershan / Prayaga Precision , Glass Magnifying Specification - Ø 75 Mm Make - Nitro / Mukul Enterprises / V Tech / Oxford /Eisco , Gmaw Torch Nozzle Tip Specification - Size 0.8, 1.0, 1.2 (In Mm) Make - Esab / Miller / Honely/ N G Weld / Gmaw Torch , Goggles (Fibre Plastic Cup) Safety Glasses (Transparent Glasses) Specification - Standard Make - Esab / L&T/ Miller/ N G Seld / Jaxy Eye Wear / Kumsons / Kti , Groover Specification - 3, 4, 6 Mm Make - Tool Buy / Halinex Steel / Mahabali Steel , Hack Valve Make - Demfost , Hack Saw Frame Fixed Specification - 300 Mm Make - Taparia / Sagar / Samrat/ Lovely / Lenox /Wulf / Jolly , Hacksaw Frame Adjustable Specification - 200 - 300 Mm Make - Taparia / Sagar / Samrat/ Lovely / Lenox /Wulf , Hacksaw Frame Fixed Specification - 150 Mm Make - Taparia / Sagar / Samrat/ Lovely / Lenox /Wulf , Hacksaw Frame Solid Type Specification - 300 Mm Make - Taparia / Sagar / Samrat/ Lovely / Lenox /Wulf , Hammer (Nylon Face) Specification - 30 Mm Make - Taparia / Sagar / Samrat / Flucon / Cromwell Tools , Hammer Copper With Handle Specification - 1 Kg Make - Taparia / Sagar / Samrat/ Wedco / Lovely / Cromwell , Hammer Mallet Make - Taparia / Sagar / Samrat / Proxima /J K Maini / Bombay Tools , Hand Drill Machine Cap Specification - Capacity 6 Mm Make - Prabhat Enterprise / High Life Indu /Sagar , Hand Operated Crimping Tool For (I) Crimping Up To 4Mm And (Ii) For Crimping Up To 10 Mm Specification - Used For Lan Crimping Make - Harting Hand / Knipax/ Hks , Hand Reamers Adjustable Specification - 10.5 To 11.25 Mm, 11.25 To 12.75 Mm, 12.75 To 14.25 Mm, 14.25 To 15.75 Mm Make - J.K / Taparia / Sagar/ Omex / Bharat Tools /West Sard / Addison , Heating Kit With Infrared Bulb Specification - 200 W Capacity Make - Philips / Crompton/ Bajaj / B. Arm Medical / Bgi Tools , Hollow Punch Set Of Seven Pieces Specification - 6 Mm To 15Mm Make - Bgi Tools / East Man / Taparia , Injector Cleaning Unit Specification - Std 0-140 Psi Make - Techmo / Taparia / Sagar/ Atp/ Biltek / Uprima , Knife Double Bladed Electrician Specification - 100 Mm Make - Taparia/Sagar / Samrat /Bgi , Leather Apron Leather Make - Esab / Seema / Messer/ /Crux Weld India / Pyrotec India , Leather Hand Sleeves Specification - 16 Make - Esab / Seema / Messer / Sparkle Enterprise / Safety Product Pvt Ltd , Leg Guards Leather Make - Esab / Seema / Messer / Karam Safety / Unique Udyog , Magneto Spanner Set Specification - 8 Spanner Set Make - Taparia / Sagar / Samrat / Bgi/ Lms Lichfield , Magneto Spanner Set With 8 Spanners Make - Taparia / Sagar / Samrat / Bgi / Lms Lichfield , Magnifying Glass 75 Mm With Magnifying Factor 10 X Specification - Ø 75 Mm X 10X Make - Sagar /Samrat /Oxford / Eisco , Measuring Steel Tape Specification - 5 Meter Make - Taparia / Sagar / Samrat / Freemans / Yorker / G R Mart , Multi Angle Magnetic Clamp Set Specification - Metal Base (18X10X10 Cm) Make - Niconself / Taparia / Sagar / Homdum / Flemingo / S M Extrusion , Multi Meter Digital Type Specification - Lcd Display Make - Mahesh / Mino Impex / Bsk Technologies / Mastak/Meco / Fluke , Neon Tester Specification - 500 V Make - Taparia / Sagar / Samrat / Tata Sampann , Oil Pump For Dismantling And Assembling. Make - Ford / Mahindra / Tata / Automotive , Parallel Shank End Mills Specification - Ø6, Ø10 And Ø 16 Are (Double Fluted), Ø 20 Mm & Ø 25 Mm (Four Fluted) Make - Addison / It / Sandvik / Miranda , Pipe Cutter Wheel Type. Specification - Capacity 06 Mm To 25 Mm Make - Bgi /Vici Joor /Tameson , Pipe Cutting Tool Tube Cutting Tool Specification - 150 Mm Make - Taparia/Sagar / Samrat /Ingco /Ridgid /Jon Bhandari , Pipe Flaring Tool Specification - 3/16,5/8 Clamp Make - Hvac/ Lovely / Sartaj/ Taparia /Digicop / Ingco , Piston Ring Expander And Remover. Specification - Standard Size Make - Mega / Aramox / Aasons , Plumbing Hammer Ball Pen Specification - 200 Grams Make - Taparia/Sagar / Samrat / Bgi / Forbes Kenpo , Portable Oil Monitoring Indicator Make - Semco / Flowtech Measuring / Fill Pro Sensors/ Spike Control / Spacon Instrument , Power Tools For Fastening Specification - Capacity 10-18Mm Make - Bosch / Taparia / Sagar /Ingico / I Bell /Tomahawk , Punch Letter Specification - 5 Mm Make - Taparia / Sagar / Samrat / Somnex / Keshav Letter / Rs Pro , Rake Maker Make - Blace Buro Tools , Rawal Plug Tool Specification - 6 Mm Make - Lovely / Metro Tools /Mm Tools , Scissors Blade Specification - 200 Mm Make - Rs Pro /Madan /William / Gemsy , Scissors Blade Specification - 150 Mm Make - Rs Pro /Madan /William / Gemsy , Screw Driver Specification - 200 Mm X 9 Mm Blade Make - Taparia / Sagar / Samrat , Screw Driver Specification - 300 Mm X 9 Mm Blade Make - Taparia / Sagar / Samrat , Set Of Sockets Morse Taper Specification - (0-1, 1-2 And 2-3) Make - Repair Renovation Brand / Simren Tools / Misumi India , Set Of Stock And Dies -Metric Specification - M6 To M24 Make - Taparia / Sagar / Samrat / C K Tools / Bgi / Meesho / Gsk Cut / Indittust , Sheet Metal Gauge Specification - Standard Size Make - Fine Teck Engg/ Super Gauge India / Laxmi Indu , Shell End Mill Specification - Ø 50 X 36 X Ø 22 (Preferably Inserted Tip Type) With 50 Insert Make - Addison / It / Sandvik / Edge India /Misumi India /Maxwell Tools , Shell End Mill Specification - Ø 75 Mm X 50 X Ø 27 (Preferably Inserted Tip Type) With 50 Insert Make - Addison / It / Sandvik / Edge India / Misumi India / Maxwell Tools , Side And Face Cutter Specification - Ø 80 X 10 X Ø 27 Mm Make - Addison / It / Sandvik /Maxwell /Rewo /Indian Tools / Misumi India , Side And Face Milling Cutter Specification - Ø 100 X 10 X Ø 27 Mm Make - Addison / It / Sandvik /Maxwell /Rewo / Indian Tools /Misumi India , Sine Bar With Centers Specification - 200 Mm Make - Cristal / Mitutoyo /Unity Marketix Pro /Groz Engg /Sheth Engg , Single Angle Cutter Specification - Ø 75 X 16 X Ø 27 - 60° Make - Addison / It / Sandvik /Misumi India /Maxwell /Dzc Tools , Sleeve Drill Morse Taper Specification - No. 0 - 1, 1-2, 2-3, 3 - 4, 4 -5 Make - Bds Machine Porttd /Rr /Trumil / Othmro / Samarat / Tapariya , Slip - On Forged Steel Flange Specification - 150 Nb, Ansi-B16.5 Make - Britex Engg /Octal /Api International /Dhanwant Metal /Riddhi Siddhi Metal , Smoothing Cutters Specification -50 Mm X200 Mm Make - Addison / Taparia / Sagar / Lindstrom /Knifex /C K Senso Plus / Bgi Tools , Snip Bent Left Cut Specification - 250 Mm Make - Taparia / Sagar / Samrat /Bgi Tools /Stanley /Hogert , Snip Sheet Metal Curved Nose Specification - 200 Mm Make - Taparia / Sagar / Samrat /Bgi Tools /Rs Combonents /Hoffmann , Snip Sheet Metal Straight Nose Specification - 200 Mm Make - Taparia / Sagar / Samrat / Bgi Tools /Rs Combonents / Hoffmann , Soldering Copper Hatchet Type Specification - 500 Gms Make - Taparia/Sagar / Samrat / Lovely /Estovir Tech / Daga Metal / N S Soldertek , Spanner Clyburn Specification - 150 Mm Make - Taparia / Sagar / Samrat /Stonley , Spanner T. Flocks For Screwing Up And Up - Screwing Inaccessible Positions Specification - 8 Mm To 32 Mm Make - Taparia / Sagar / Samrat /Hamco Is Pat Pvt / Multiac /As Man Tools India , Spanner T. Flocks For Screwing Up And Up -Screwing Inaccessible Make - Taparia / Sagar / Samrat /Hamco/ Maltitec /Asmaa , Spark Plug Spanner Specification - 14 Mm X 18 Mm X Size Make - Classic /Mec /Jpt /Autoplex , Spindle Key Specification - Smwop Hi-Tech Make - Addison / Taparia / Sagar / Bgi Tools /Abm Tools / Hero , Spirit Level Engineers Precision Specification - 25 Mm Make - Freemans /Bosch /Magnetic / Taparia , Spirit Level Metal Type - 2 Specification - 300 Mm Basic Length, Accuracy 0.1Mm/Meter Make - Taparia / Sagar / Samrat / /Fremans /Basch , Spirit Level Precision Metallic Specification - 0.05 Mm / 200 Mm Make - Taparia / Sagar / Samrat /Bgi Tools /Fremans /Bosch , Spring Tension Tester Specification - Standard Make - Jk Automation / Canon Testing / Star Identification , Stake Hatchet Specification - 300 X 200 X 20 Mm Make - Taparia / Sagar / Samrat /Bgi Tools Diamond Tools , Stake Grooving Specification -100 X100X 300Mm Make - Taparia / Sagar / Samrat /Bgi Tools /Diamond Tools , Static Balancing Stand For Grinding Wheel Specification - Ø 450 Mm Wheel Make - Vertex /World Wide Engg /Precision Machine , Grind Store Machinery India , Steel Measuring Tape 10 Meter In A Case Specification - Meter Make - Ereemans /Amici Tools / Total Steel , Stud Extractor Ezy - Out Specification - Set Of 8 Make - Chaudhari Enterprises / Bgi Tools /Prokomon , Stud Extractor Set Of 3 Specification - Assorted Size Make - Taparia / Sagar / Samrat / Bgi Tools /Prokomon , Stud Remover With Socket Handle Specification - Standard Size Make - Taparia / Sagar / Samrat / Dewill /Prokoman / Bgi Tools , Surface Plate - Granite With Stand And Cover Specification - 1000 X 1000 Mm Make - Luthra /Mgre /Ntmt/ Prime Autotech / Omega / Sagar , T Slot Cutter With Parallel Shank Specification - Ø 17.5 X 8 Mm Width X Dia. Of Shank 8 Mm Make - Addison / It / Sandvik / Dic Tools /Abm Tools /Jyoti Tools , Tap & Die Specification - B. A. No. 0 To 10Mm In A Box Make - Humma / Taparia / Samrat / Chapional / Hogert / Totem , Tap & Die Set Specification - B.S.F. Up To 1 Inch Make - Humma / Taparia / Samrat /Champion /Hogert / Totem , Taper Shank Drills Specification - Ø 12 Mm To Ø 20 Mm In Steps Of 1 Mm Make - Addison / It / Sandvik / Cromwell Tools /Dic Tools , Taps And Dies Complete Set Specification - 5, 6, 8, 10 & 12 Mm Set Of 5 Make - Humma / Taparia / Samrat / Cromwell /Dic / Bgi / Hogert / Totem , Taps And Dies Complete Set In Box (Metric) Specification - Metric Size Make - Humma / Taparia / Samrat / Cromwell / Dic /Bgi / Hogert / Totem , Taps And Dies Complete Sets (5 Types) Make - Humma / Taparia / Addison / Hi Spec Metric / Hogort , Taps And Top Wrenches - Metric Specification - Metric Size 6 To 18 Mm Make - Humma / Taparia / Samrat /Yato / Assorts Repair Renovation /Acs Tools /Groz Tap Wrench , Temperature Gauge Dial Type - 4 Ø Specification - 0 - 100 Deg Make - Mitutoyo / Yayin Automation / H -Guru / Ji Japsin / Dulux / Becco , Tenon Saw Specification - 250 Mm Make - Taparia / Sagar / Samrat / Spear & Jackson / Irwin / Presyo Tenon , Tool Makers Button Specification - Assorted Size Make - Taparia / Sagar / Samrat / Bgi Tool /Cromwell , Try Square Engineer Specification - 150 Mm Make - Taparia / Sagar / Samrat / Rs Componnents / Craftsman Space / Kristeel , Tweezers, Ss Specification - 150 Mm Make - Mehta Tools /Misumi India / Sun Rise Tools , Valve Spring Compressor Universal Specification - Standard Make - Tarpaia / Sagar / Samrat / Bgs /Automartez / Universal / Prodiy , Welding Hand Shield Fibre Specification - Visor Thickness 600 Micron Size Medium Make - Miller / Esab / L&T /Safety Weld Hand , Welding Helmet Fibre Specification - Superfine Fibre Make - Miller / Esab / L&T /Safety Weld Hand , Wire Gauge (Metric) Specification - Standard Size Make - Bgi Tools / Thermo / Kristel Epi Tech , Wire Gauge Metric & British. Specification - Steel Plate Embossing Converse Of British & Metric Make - Bgi Tools / Thermo /Kristel / Epi Tech , Wood Firmer Chisel Specification - 6,12,25 Mm Make - J.K / Sagar / Samrat /Ronix Tools /Bgi Tools /Henry Taylor , A.C. Energy Meter Specification - Three Phase, 15 A , 440 V Induction Type Make - Meco / Mahesh / Techno Meters & Electronics / Ampro / Bgi / Boparai , A.C. Energy Meter Specification - Single Phase, 10 A, 240 V Induction Type Make - Meco / Techno / Hpl /Ampro / Bgi / Boparai , Ac Starters Make - Siemens / Crompton / L&T /Havells /Boparai A. Resistance Type Starter Make - B. Direct On Line Starter Make - C. Star Delta Starter- Manual Make - D. Star Delta Starter - Semi Automatic Make - E. Star Delta Starter - Fully Automatic Make - F. Star Delta Starter - Soft Starter Make - G. Auto Transformer Type Make - Specification - For A.C Motors Of 2 To 5 H.P. Make - , Battery -Charger Specification - 0-6-9-12 -24 - 48 V, 30 Annual Periodical Maintenance Make - Sony/ V-Tec / Erh /Rainbow /Protech Engg /Luckgulu , Blow Lamp, L P Gas Specification - 1 Litre Make - Dws Blow Long /Bgi Tools , Brake Test Arrangement With Two Spring Balance Rating Specification - 0 To 25 Kg Make - Bgi Tools /R Tech Enterprise / J J Techro Sol , Car Jet Washer With Standard Accessorise Specification - Minimum3 Phase 1Hp 1400 Rpm Motor, 3 Reciprocating Plungers With Pressure Regulator & Gauge. 8 M Water Hose With Pressure Adjustable Brass Nozzle. Make - Elgi / Rotomac / Auto Man Unicorn/ Bosch /Power Wash /Bgi , Compressors Testers For Small Hermetic Compressors Specification - Fixed With Electrical Input / Output Indicating Facilities Make - Siemens / Crompton / L&T / Bgi Tools /Amv Scientific Construction Of , Current Transformer Specification - 415 V, 50Hz, Ct Ratio 25 / 5 A, 5Va Make - Mahesh / Meco / Teco /Schneider Elect /Lct , Cylinder Liner- Dry & Wet Liner, Press Fit &Slide Fit Liner Specification - Standard Make Make - Bgi Tools / Kirloskar / Mahale / Tata , Dc Power Supply Specification - 0 - 30 V, 5 Annual Periodical Maintenance Make - Mahesh / Meco / Teco /V Guru /Sugon /V. Annual Repair T Ech Hori , Different Type Of Piston Model Flat Head, Convex, Concave, Deflector Etc. Specification - Standers Acc. Size Make - Cummins / Super King / Jindal/ Dynamic Piston / Ipl /Mexon Piston / Jj Raj Piston , Digital I.C. Trainer Specification - Digital I.C. Trainer 7 Segment Display And Bread Board Make - Micro Logics / Crown / Sceniot Technologist/ Bgi Tools / Maxwell , Discrete Component Trainer Specification - Discrete Component (For Diode And Transistor Circuit) With Regulated Power Supply + 5,0- 5 V,+12 ,0-12 V Make - Micro Logics / Crown / Sceniot Technologist/ Maxwell /Eductek /Mars / Neofit , Electric Iron Specification - Automatic - 750 W, 240 V Make - Philips / Crompton/ Bajaj / Lg / Havells /Usha , Electric Kettle Specification - 1500 Watts, 240V Make - Philips / Crompton/ Bajaj / Lg / Milton /Borosil , Fuel Injection Pump (Diesel) Inline / Mahindra Xlehide Make - Mico / Dolphine / Taparia / Bosch /Suntec /Grozloonfoss , Fuel Injection Pump Ve Pump / Distributor Fuel Rotary Pump (Dpc) Pumps / Along With Special Tools And Accessories Specification - Standard Make - Mico / Bosh/ Dolphin /Suntec / Groz /Danfoss , Function Generator Specification - 2 To 200 Khz, Sine, Square, Triangular 220 V, 50 Hz, Single Phase. (Digital Type) Make - Aplab / Sigma / Siemens / Alfa / Ses Instruments /Mars , Gauge, Wire Imperial Stainless Steel Marked In Swg & Mm Specification - Wire Gauge - Metric Make - Osar /Bgi , Geyser (Storage Type) Specification - 10 Litre Make - Bajaj / Philips / Lg /Orient / Aosmith /Havells , Granite Surface Plate Specification - 1600 X 1000 With Stand And Cover Make - Luthwa / Mgre / Prime Ficutech , Granite Surface Plate Specification - 600 X 600X80 Mm Make - Luthwa /Mgre /Ntmt /Prime Acetech / Omega / Sagar , Growler Make - Keg / Tm Craft / Ukeg , Hacksaw Fixed (Pistol Grip) Specification - 200 Make - Cristal / Taparia / Sagar /Lovely /Lanox /Wulf , Hydraulic Jack Hi-Lift Type - Heavy Duty Specification - 3 Ton Capacity Floor Trolley Make - Appex / Tools Vhlla/ Mogilx/ Elephant /Hukums /Marshal , Hydrometer Make - Mahesh / Meco / Teco /Ajanta /Beawmes /Micro Teknic /Lab Soul , Immersion Heater Specification - 1500 Watt, 240V Make - Philips / Crompton/ Bajaj / Lg/ /Havells , Injector - Pintle Type Multi Hole Specification - Tata Motor / Mahindra Make - Mico / Winmax/ Surya / Cummins , Injector Testing Set Specification - (Hand Tester) Make - Mico / Winmax/ Surya /Gallop / Bosch /Rashi Tools , Knife Switch Dpdt Fitted With Fuse Terminals Specification - 16 Annual Periodical Maintenance Make - Ashoka / Filnor / Radioshack /Bgi Toools /Sdm /Stonley , Knife Switch Tpdt Fitted With Fuse Terminals Specification - 16 Amp/ 440 V Make - Ashoka / Filnor / Radioshack / Stanley , Laboratory Type Induction Coil Specification - 1000 W Make - Siemens / Meco / Philips /Bgi /A G Enterprises , Lifting Jack Screw Specification - 20 Ton Make - Appex / Universal / Bajaj / Bharat /Indeer /Marshal , Lifting Jack Screw Type Specification - 3 Ton Capacity Make - Appex / Universal / Bajaj /Bharat /Indeer /Marshal , Limit Switch Specification - Limit Switch, Liver Operated 2A 500V, 2- Contacts Make - Siemens / Meco / Philips /Oxcell /Pizzato /Vraj , Linear I.C. Trainer Specification - Linear I.C. Trainer With Regulated Power Supply 1.2V To 15V Pic Socket 16 Pin And 20 Pin With Bread Board Make - Micro Logics / Crown / Sceniot Technologist /H L Scientific / Chopra & Construction Of /Maxwell , Load Bank ( Lamp / Heater Type) Specification - 6 Kw, 3Ph Make - Geltronix / Onics / Akansha / Bgi Tools /Jayram Electronics , Lux Meter Specification - Lux Meter Lcd Read Out 0.05 To 7000 Lumens With Battery Make - Mahesh / Meco / Teco /Flute / Extech Instrument , Magnetic Flux Meter Specification - 0-500 Tesla Make - Taparia/Sagar / Samrat /Aptex /Polytronic , Marking Out Table Material Cast Iron With Mild Steel Std. With Std. Specification - 90X60X90 Cm. Make - Omega / Taparia / Sagar / Luthera / Bgi , Mccb Specification - 100Amps, Triple Pole Make - Siemens / Meco / Philips / Schenider /Polycab /L & T , Megger, Hand Driven Specification - Analogy - 500 V Make - Aplab / Meco / Siemens / Denko /Yokins /Waco Yokins / Waco , Megger Specification - 1000V Make - Aplab / Meco / Siemens / Denko , Mixture & Grinder Domestic Specification - 750 W, 240 V Make - Sumit / Philips / Jyot//Bajaj , Multi Meter Analogue Type Make - Mahesh / Meco / Teco/ Hlt / Hanna /S L Tech /Metravi Instrument , Ohm Meter; Series Type & Shunt Type, Portable Box Type Specification - 50/2000-Ohm Analog Make - Mahesh / Prestige Electronics / Otwane//Tekson /Bgi , Oil Testing Kit Specification - Oil Testing Kit 230 V, Single Phase 50 Hz 60 Va Output 0-60 Kv Variable Make - Bosch / Aajjo / Deluxe Corporation /Kleenoij /Visgae , Pin Type, Shackle Type, Egg Type & Suspension Type Insulators Including Hardware Fitting Specification - N.A Make - Bgi /Adity Birla Insulation / Dhel Insulators , Pipe Bender M/C Spool Type With Stand Manually Operated Up To 25 Mm Cold Bending Specification - Up To 25 Mm Cold Bending Make - Humma / Taparia / Sagar / Voltz / Tools Villa / Bgi , Potential Transformer Specification - 415 V, 50Hz, Pt Ratio, 440V/110V,10Va Make - Meco / Electronic / Acme /Eteva / Mpi / Brilltech /Macro , Power Supply Specification - 0-12 V, Lamp Make - Anchor/ Skyska / Philips /Mw / Parker , Quick Couples, Process Tube Adopter Specification - ¼ & 3/8 5/16, 3/16 Make - Tmc /Robinar /Parkar , Rheostat (Sliding Type) Specification - 0 - 25 Ohm, 2 Annual Periodical Maintenance 0 - 300 Ohm, 2 Annual Periodical Maintenance 0 -1 Ohm, 10Amp 0 -10 Ohm, 5 Annual Periodical Maintenance Make - Micro Technologies / Avain Lab / Tilak Scientific / H L Scientfic / Mahehsh Electric /Ajanta , Rotary Switch Specification - 16 A/440V,3Positiom Make - Meco / L&T / Servo / V Guard / Suraj /Salzeer , Set Of Stock And Dies - Unc, Unf And Metric Specification - Standard Make - Humma / Taparia / Sagar /Cromwell Tools /Atson Tool / Totem , Single Phase Variable Auto Transformer Specification - 0-270 V, 10Amp (Air Cooled) Make - Crown / Sabtron / Sky King /Sunmach /Radic Electric , Solar Panel With Battery Specification - 18 Watt Make - Tata Power Solar/ Adani Solar/ Vikram Solar/ V Guard /Micro Kk , Stop Watch Specification - N.A, Dial Type Make - Swastik / Sidhi Ent. Top Sun /Edutek /Sagar /Pravin , Surface Plate C.I / Granite With Stand And Cover Specification - 600 X 600 Mm Make - Omega / Taparia / Sagar /Luthra /Mgre /Prime Pautech , Tachometer Specification - Analog Type - 10000 Rpm Make - Mitutoyo / Monarch / V Tech /Lutron /Maxtech /Nutronics , Tachometer Specification - Digital Photo Sensor Type - 10000 Rpm Make -Mitutoya /Monarch /V Tech /Maxtech , Tachometer (Counting Type) Make - Meco / Ajanta Export / Micon / Mitutoyo / V Tech , Thermometer Digital Specification - 0° C - 150° C Make- Fibrecrafts India /Spaark Enterprises /H Guru , Thread Pitch Gauge Metric Bsw Specification - No-188 - 122 Make - Mitutoyo /Universal Gauges Rq Ltd / M -Tech Enterprises , Tong Tester / Clamp Meter Specification - 0 - 100 A (Digital Type) Make -Cbm / Divinext /Meco /Kusum , Voltage Stabilizer Specification - Ac Input - 150 - 250 V, 600 Va Ac Output - 240 V, 10 A Make - Bajaj /Crompton / L&T /V Guard / Microtek , Wattmeter Multi-Range Up Specification - 1 Kw Make - Mahesh / Meco / Teco /Yokins / L& T / Cimicisense , Wheat Stone Bridge With Galvanometer And Battery Specification - N.A. Make - Samuel / Tvs / Kalyani /Sametech /Ortex Electronics , Belt Tensioner Gauge Specification - Measurement Range -0-2000 Gauss Measurement Mode Touch Rzobe Resolution - 0.1 Make - Timken Belt / Emf Lurton Precision / Unite - Japan/Otc Tools /Hari Om Electronics / Sonic , Capillary Plug Gauge Specification - 026 To 090 Inch Make - Charlie /Misumi India /Hvzc , Compound Gauge, Digital Type Specification - Diameter 63Mm, With Calibration Set Screw, Scale Vacuum 760Mm Make - Elitech / Jaco / Accutire/Ashcroft /Japsin Instru / Millennium ,Installation , Compression Testing Gauge Suitable For Diesel Engine With Standard Accessories Specification - Capacity 25Kg/Cm2/450 Make - Universal /Sthira /Zorbes/ Toptul , Different Profile Gauges (Plate Type) - For Demonstration Specification - Metric Standard Make - Bgi /Swaroop Autotech , Digital Thermometer Metal Case Specification - Graduated Disc Analogy Type Make - Demfos / Bsk Techoo /Dynamic Gauge Pvt Ltd /Esaw , Engineers Stethoscope Specification - Standard Make - Excluzo Automotive / Taparia /Sagar /Abn Machines / Shakun Dr. More Pen , Gauge - Radius Set Specification - 1 Mm To 25 Mm By 0.5 Mm Make - Kristee /Groz /Inder /Pro , Gauge Plug Specification - Single Ended 5 To 55 By 5 Mm Set Of 11 Pcs Make - Bgi /Mahalaxmi Enterprises / Cromwell Tools , Glow Plug Tester, Std Size Make - Lupson / Mitutoyo /K S Tools /Hogert /Modtech , Multi Meter Digital Specification - Lcd Display Make - Mahesh /Themis To /Mastech , Pressure Gauge Digital Type Specification - Diameter 63Mm With Recalibration Set Make - Elitech / Jaco / Accutire / Neco /Wika / H Guru /Winter , Raiser Specification - 3 Furrow Make - Bahubali /Shaktiman , Screw Pitch Gauge Specification - Acc. Size Make - Mitutoyo / Taparia / Samrat /Kristee /Misumi , Tyre Pressure Gauge With Holding Nipple Specification - 10 Kg /Cm2/150 Ebs / 59 Inch Make - Elgi / Sagar / Samrat / Bgi / Micro Lube /Airmaster , Universal Surface Gauge Specification - 250 Mm Arm Make - Krystal / J Lab /J D Engg / Samrat / Sagar , Vacuum Gauge To Read Specification - 0 To 760 Mm Of Hg. Make - Asama /Sagar /Summit / Tameson /Prm /H Guru , Vernier Calliper Outside, Inside And Depth Specification - 200 Mm /8 Inches With Metric & Inch Scale (L.C. = 0.02Mm) With Nabl Accredited Lab. Certificate Make - Moglix /Yuzuki /Sanyo / Kanon / Mitutoyo , A 4 Cutting Wheels Make - Dewalt / Esab / Messer / Bosch /Dura- Kut /Euromax , A 4 Grinding Wheels Make - Dewalt / Esab / Messer / Bosch /Dura-Kut/ Uromax , Annual Rate Contract Welding Cables Multi Cored Copper Specification - 400/600 Annual Periodical Maintenance As Per Bis Rebel Make - Dewalt / Esab / Messer / Bhurwal /Megacab /Polycab / Neon / Johnson
Contract Date: Ref. Documents Contract Value : Ref. Document
Trust & NGO No of Bidders 2
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 7.00 Lakh
Boards / Undertakings / PSU No of Bidders 2
11.
Educational and Research Institute #10967168 AOC
Equipment For Civil Lab Equipment For Civil Lab, Basic Civil Lab, Transport And Highway Lab, Advance Structural Lab , Equipment For Basic Civil Engineering Laboratory (Sheet 1) , Equipment For Advanced Structural Testing Laboratory(Sheet 2) , Equipment For Transportation & Highway Laboratory (Sheet 3) , Service(Sheet 4)-1 1 Concrete Mixer, Pan Type 2 Mould, Cast Iron, for 150mm Cube with ISI marked and NABL calibration Certificate 3 Beam Mould, 100mm x 100mm x 500mm 4 Beam Mould, 150mm x 150mm x 700mm 5 Cylindrical Mould, Cast Iron, Split Lengthwise 150 mm diameter x 300mm high 6 Mould, Steel, for 70.6mm cube with ISI Mark and NABL calibration Certificate 7 Tamping Rod 8 Vibrating Table 9 Slump Test Apparatus 10 Consistometer (Vee Bee Consistometer) 11 Flow Table, Motorized 12 Compaction Factor Apparatus 13 Concrete Penetrometer, Spring Type 14 Air Entrainment Meter Capacity 0.005m3 (5 liters) suitable for aggregate size up to 38mm 15 Curing Tank for 6/24moulds of 150mm/70.6mm size with NABL Calibration Certificates 16 Accelerated Curing Tank for 6 moulds of 150mm size with NABL Calibration Certificates 17 Capping Set, Vertical, for capping 150mm dia cylinders and cores 18 Concrete Permeability Apparatus 19 Compressor for Permeability Apparatus 20 Air Permeability Apparatus (Blaine type) 21 Vicat Apparatus 22 Le-Chatelier Mould 23 Le-Chatelier Water Bath with Controller 24 Le-Chatelier Flask 25 Shrinkage Bar Mould with NABL Calibration Certificate 26 Cement Autoclave 27 Length Comparator, Digital 28 Flow Table, Electric Operated 29 Automatic/Manual Digi Mortar Mixer Capacity 4.75litre 30 Vibration Machine, with built-in Digital Timer, NABL Calibrated 31 Gauging Trowel 32 Gauging Trowel 33 Sieves Set (Course) 34 Sieves Set (Fine) 35 Concrete test Hammer 36 Automatic Compression Testing Machine 37 Flexure Test Attachment 38 RCPT (4 CELL MODEL) 39 Drying Shrinkage 40 Carbonation Test Chamber 41 1000kN Beam Testing Set Up 42 Pycnometer 43 Pull off tester 44 Hot Air Oven 45 Sieve shaker (Motorized) 46 Sieve shaker (Motorized) 47 Electronic Weighing Balance with Legal Metrology Test Certificate 48 Electronic Weighing Balance with Legal Metrology Test Certificate. 49 Electronic Weighing Balance with Legal Metrology Test Certificate. 50 Electronic Weighing Balance with Legal Metrology Test Certificate. 51 Electronic Weighing Balance with Legal Metrology Test Certificate. 52 Impact of Jet on Vanes Apparatus 53 Orifice Meter Apparatus 54 Flow Over Notch Apparatus 55 Friction in Pipelines Apparatus 56 Venturimeter Apparatus 57 Orifice & Mouthpiece Apparatus Bernoullis Theorem Apparatus 59 Reynolds Apparatus60 Metacentric Height Apparatus 61 Study of Pipe Fittings, Sudden Enlargement & Contraction Apparatus 62 Force Vortex Apparatus 63 Pelton Wheel Turbine Test Rig 64 Francis Turbine Test Rig 65 Reciprocating Pump Test Rig 66 Standard Penetration Test (SPT) 67 `A Drill Rod, 1m long complete with adaptor 68 Dynamic Cone Penetration Test Apparatus (DCPT) 69 `A Drill Rod, 1m long complete with adaptor 70 Hand Operated Extractor 38mm mm dia specimen 71 Sampleject-5000, Hydraulic sample extruder, Electronic cum hand operated 72 Speedy Moisture Meter, Range 0-25% (Gauge Div.:0.5%) with digital weighing balance 73 Infra-Red Moisture Meter 74 Liquid Limit Device, motorised, with Casagrande grooving tools and gauge block 75 Liquid Limit Device, Hand Operated, with Casagrande grooving tools and gauge block. 76 Plastic Limit set comprising of glass plate, Brass rod, Spatula, Moisture Tin & Porcelain Dish. 77 Shrinkage Limit Set 78 Universal Penetrometer 79 Penetration Test Cone 80 Penetration Test Cup, 55 mm dia x 50 mm deep 81 Pycnometer 82 Andreasen Pipette Stand 83 High Speed Stirrer New Model 84 Hydrometer, Range: 0.995 to 1 Measuring specific gravity of liquid against buoyancy. Used for particle size analysis of fine grain soil less than 75-micron size 85 Plummet Balance 86 Unconfined Compression Tester for load measurement 87 Digital Direct Shear Test Apparatus, 2kN 88 Compaction Test Apparatus, Manual -Light Compaction made of Mild Steel 89 Compaction Test Apparatus, Manual-Heavy Compaction made of Mild Steel 90 Universal Automatic Compactor with Mild Steel compaction mould 91 Relative Density Apparatus 92 Soil Permeability Apparatus 93 Overhead Tank, made of steel, approx., 37.5cm dia x 1m high 94 Grooved M.S. Plate, 30cm x 30cm square x 25mm thicks + Plate bearing Apparatus with Load Truss of 500kN 95 (Plate Bearing Apparatus) 96 Core Cutter 97 Triaxial Shear Test Apparatus 98 Sand Replacement Method Apparatus 99 Van Shear apparatus 100 Electronic Three Gang Bench Type Consolidometer Front Loading 101 Hot Air Oven 102 Sieve shaker (Motorized) 103 Field CBR Test Apparatus with Proving Ring and Dial Gauge 104 BOD Incubator 105 Turbidity Meter 106 pH Meter 107 Conductivity meter 108 Portable UV Visible Spectrophotometer 109 Dissolved Oxygen meter 110 Portable COD meter 111 TSS analyser 112 TDS Analyzers 113 Particulate Matter Sampler 114 Hot Air Oven 115 Muffle Furnace 116 Digital Colony Counter 117 Water bath 118 Open Reflux COD Digester 119 Electronic Weighing Balance 120 Electronic Weighing Balance 121 Infrared thermometer 122 Microscope 123 Magnetic Stirrer with hot plate 124 Jar Test Apparatus Flocculator 125 Test tube 126 BOD Bottle 127 Porcelain dish 128 Measuring cylinder 129 Filter Paper 130 Burette 131 Burette stand with rod, clamp & boss head 132 Needle Vibrator 133 Vibratory hammer 134 Concrete specimen cutter 135 Curing Tank 136 Accelerated Curing Tank 137 Compressor with Nozzle 138 Deep Refrigerator 139 Refrigerator 1 Thickness Gauge 2 Length Gauge 3 Aggregate Impact Tester 4 Crushing Value Apparatus 5 Los Angeles Abrasion testing machine with counter 6 Density Basket 7 Buoyancy Balance 8 Universal Penetrometer 9 Penetration Cone 10 Bitumen Penetration Kit 11 Ring and Ball Apparatus 12 Thermometer IP 60C 13 Thermometer IP 61C 14 Thermometer IP 8C, Range 0°C to 45°C 15 Thermometer IP 9C, Range 40°C to 85°C 16 Thermometer IP 10C, Range 76°C to 122°C 17 Cannon Manning cum Cannon Fenske Viscometer bath with Vacuum Pump 18 Cannon Manning Vacuum Viscometer Tube, Size 6 19 Cannon Manning Vacuum Viscometer Tube, Size 7 20 Cannon Manning Vacuum Viscometer Tube, Size 12 21 Cannon Manning Vacuum Viscometer Tube, Size 13 22 Thin Film Oven/Loss on Heating Oven 23 Rolling Thin Film Oven 24 Flash Point (Closed) Pensky-Martens Apparatus 25 Thermometer IP 15C Range 5°C to +110°C 26 Thermometer IP 16C Range 90°C to +370°C 27 Flash Point (Open) and Fire Point, PenskyMartens Apparatus 28 Thermometer IP 15C Range 5°C to +110°C 29 Thermometer IP 16C Range 90°C to +370°C 30 Specific Gravity Bottle 31 Ductility Testing Machine with Digital Temperature Indicator 32 Centrifuge Extractor with NABL Calibration Certificate. 33 Marshall Apparatus, 50kN Single Speed 4 Diameter Sample 34 Pavement Core Drilling Machine 35 Diamond Core Bit 36 Asphalt Mixer, 5 L Capacity 37 Skid Resistance Tester 38 Asphalt Mixer Theoretical Density Meter 39 Modified Roughness Indicating Machine (MERLIN) 40 Bump Integrator with pre-set facility and CRRI calibration certificate 41 Pavement Dynamic Cone Penetrometer 42 Film Stripping Device 43 Saybolt Viscometer 44 Mastic Asphalt Tester 45 Serological Water Bath, Double Walled, with Digital Controller Cum Indicator and Stirring Arrangement 46 Brookfiled Viscometer 47 Thin Film Oven 48 Ignition Oven Asphalt Content Tester with IRC Accreditation. 49 Marshal Automatic Compactor 50 Roughometer (wireless) 51 Radar Gun 52 Helium Pycnometer 53 Laboratory Hot Plate 54 Sieve shaker (Motorized) 55 Sieve shaker (Motorized) 1 SCHMIDT Live N 2 Rebound Hammer Sensor Kit (For Rock) Ultrasonic Pulse Velocity 4 Profometer Rebar Detection & Cover Meter with 5 yrs. software subscription 5 Diamond Core Drilling Machine for Concrete 7 Structure Scan Mini LXT for Concrete Scanning 8 Pile Integrity Test 9 PIT-W Professional Software 10 Impact Echo 11 Light Weight Deflect meter 12 Falling Weight Deflectometer 13 Non-nuclear density gauge (for Soil) 14 Non-Nuclear Asphalt Density Gauge 15 Resistivity Meter (1-D) 16 Electrical Resistivity Imaging system & IP-System 17 Single channel & Multichannel Seismograph 18 Ground penetrating Radar (GPR) 19 Microtremor (Passive Seismic monitoring 20 Pneumatic Adhesion Tensile Strength Testing Instrument (PATTI 21 Electronic Weighing Balance with Legal Metrology Test Certificate. 22 Electronic Weighing Balance with Legal Metrology Test Certificate.
Contract Date: May 05, 2026 Contract Value : 7.71 Crore
Government Departments No of Bidders 1
12.
Information and Broadcasting #10811892 Price Bid
Tender For E-Tender For The Supply, Installation, Integration, Testing, And Commissioning Of Equipment, Computer Hardware, Software, And Accessories For Cinematography, Digital Intermediate, Audiography, Direction & Screenplay Writing, Film Editing, And Animation & Visual Effects Sections, On Academic Pricing On Turnkey Basis, Along With Comprehensive Onsite Warranty For Three (3) Years , Direction And Screenplay Writing Section - Equipment Requirements , Smart Tvpc Dell Pro Max Tower T2 - Intel Core Ultra 9 285 (36 Mb Cache, 24 Cores, 24 Threads, 1.9 Ghz To 5.6 Ghz, 65W), 64Gb (2 X 32 Gb) Ddr5 (5600 Mt/S, Non-Ecc), Nvidia Geforce Rtx 5090 32Gb Gddr7, 3Xdp, 1Xhdmi, 1Tb Ssd Tlc With Dram M.2 2280 Pcie Gen4 Sed Ready/ Dell Pro Max Tower T2 With 1500W (80 Plus Platinum) Psu V2 /Windows 11 Pro / 5 Yrs Support , Smart Tv Sony Bravia 3 Series 189 Cm (75 Inches) 4 K Ultra Ai Smart Led Google Tv , Mac Studio M3 Mac Studio, Apple M3 Ultra Chip 28-Core Cpu With 20 Performance Cores And 8 Efficiency Cores 60-Core Gpu Hardware-Accelerated Ray Tracing 32-Core Neural Engine 819Gb/S Memory Bandwidth, 256Gb Unified Memory, 2Tb Ssd, Keyboard & Mouse , External Hard Drive Seagate One Touch 20Tb Usb 3.0 Portable Hdd , Printer Hp Laserjet Mfp M438Dn Multi-Function Monochrome Laser Printer (Toner Cartridge) , Directors Viewfinder Alan Gordan Enterprises Mark Vb Directors View Finder , Video Assist Monitors Blackmagic Video Assist 5 3G 5-Inch Full Hd Lcd Touchscreen 3G-Sdi And Hdmi Inputs/Outputs Supports Up To 1080P60 Recording , Final Draft Final Draft Software Full License (Industry Standard With Life Time License) , Continuity Camera / Script Notes Camera Canon Eos R50 Mirrorless Camera Body With Rf - S 18 - 45 Mm F/4.5 - 6.3 Is Stm , Walkie-Talkies, Head Phones (Sets) Aspera V-9 License Free Walkie Talkie With Standard Accessories Viz Battery, Belt Clip, Rapid Charger And Adaptor, Helifex Antenna, User Manual. , Portable Bluetooth/Monitor Speakers (On-Set Use) Jbl Xtreme 3, Wireless Portable Bluetooth Speaker, Pro Sound With Powerful Bass Radiators, Built-In Powerbank, Partyboost, Ip67 Water & Dustproof, Aux & Type C (Blue, Without Mic) , Digital Clap Board Tribe7 Blackslate7 7.5 Clapperboard E-Image Cb-03 Advanced , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Digital Intermediate Section - Equipment Requirements , Software Davinci Resolve Software Studio Version , Software Adobe Package Software (1 Year Subscription Yearly To Be Renewed) , Software Easy Dcp Software For Resolve , Color Correction Panel Black Magic Design Davinci Resolve Mini Panel , Color Correction Panel Black Magic Design Davinci Resolve Micro Panel , Imac Mac Studio, Apple M3 Ultra Chip 28-Core Cpu With 20 Performance Cores And 8 Efficiency Cores 60-Core Gpu Hardware-Accelerated Ray Tracing 32-Core Neural Engine 819Gb/S Memory Bandwidth, 256Gb Unified Memory, 2Tb Ssd, Keyboard & Mouse With 1-Year Support , Imac Imac, Apple M4 Chip 10-Core Cpu With 4 Performance Cores And 6 Efficiency Cores 10-Core Gpu Hardware-Accelerated Ray Tracing 16-Core Neural Engine 120Gb/S Memory Bandwidth, 2Tb Ssd, 32Gb Unified Memory, 60.96 Cm (24″) 4.5K Retina Display 4480X2520 Resolution At 218 Pixels Per Inch With Support For 1 Billion Colours With 1-Year Support , Imac Mac Keyboard And Mouse Usb Hub 50000 X 1 No. , Dell Tower Work Stations Dell Pro Max Tower T2 / Intel Core Ultra 9 285 (36 Mb Cache, 24 Cores, 24 Threads, 1.9 Ghz To 5.6 Ghz, 65W) / 64Gb: 2 X 32 Gb, Ddr5, 5600 Mt/S, Non- Ecc / Nvidia Geforce Rtx 5090 32Gb Gddr7 3Xdp 1Xhdmi / 1Tb Ssd Tlc With Dram M.2 2280 Pcie Gen4 Sed Ready / Dell Pro Max Tower T2 With 1500W (80 Plus Platinum) Psu V2 / Windows 11 Pro / 5Yrs Support , Dell Tower Work Stations Logitech Mk120 Usb Keybord And Mouse , Dell Tower Work Stations Photoshop System 1 Year Licence Subcription To Be Renewed Annually , Monitor Dell Pro 27 Plus 4K Usb-C Hub Monitor - P2725Qe , Monitor Dell Pro 27 Plus Monitor - P2725H / 5Y Basic Advanced Exchange Service , Monitor Eizo Cg319X-4K / 31.1 Inches,4096X2160,350Cd/M2,Dp,Hdmi,Adobe Rgb, Built In Sensor , Tv Sony Bravia 4K Uhd Tv 65Inch , External Hard Disk Samsung Ssd 4 Tb External Hdd , External Hard Disk Seagate One Touch Backup Plus 5Tb Hdd External , Di Equipments Blackmagic Design Capture, Card Ultrastudio 4K Mini , Di Equipments Black Magic Design Ultrastudio Monitor 3G For Mac 15000 X 4 Nos , Di Equipments Black Magic Design Link Card 4K Extreme 12G , Speaker & Headphones Jbl Stage 260F, Stage 245C, Stage 240H, Stage 200P + Denon Avrx- 250 Bituminous Av Receiver 5.1 Home Theatre , Speaker & Headphones Jbl Sb180 Speakers , Speaker & Headphones Akg K52 Headphones , Accessories Wacom Intuos Bluetooth Ctl-6100/K0-Cx Digital Graphics Pen Tablet For Drawing (Black) Medium (10.4-Inch X 7.8-Inch) , Accessories Hdmi 2.1 -5 Metres , Accessoriest Thunderbolt 4(Usb-C) Pro Cable (3 Metres) , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Animation & Visual Effects - Equipment Requirements , System Lenovo Think Station Px Workstation | 2 X Intel Xeon Gold 5420+ Processor (2.00 Ghz Up To 4.10 Ghz) | 4 X 128 Gb Ddr5-4800Mt/S (Rdimm, Ecc) | 4 X 12 Tb 7200Rpm Hdd 3.5 Sata Enterprise | Nvidia Rtx A6000 48Gb | Intel Eagle Stream C741 Dual Processor Motherboard | Raid 10 (4 Drives Min) | 1 X 1 Tb Ssd M.2 2280 Pcie Gen4 Performance Tlc Opal | 1 X 4 Tb Ssd M.2 2280 Pcie Gen4 Performance Tlc Opal | Integrated Ethernet | 2 X Thermal Kit 250W | Windows 11 Pro 64Bit Pre-Loaded | Wired Keyboard & Mouse | 3 Years Onsite Warranty / Dell Ultrasharp 27 4K Thunderbolt Hub Monitor - U2725Qe , System Dell Pro Max Tower T2 / Intel Core Ultra 9 285 (36 Mb Cache, 24 Cores, 24 Threads, 1.9 Ghz To 5.6 Ghz, 65W) / 64Gb: 2 X 32 Gb, Ddr5, 5600 Mt/S, Non-Ecc / Nvidia Geforce Rtx 5090 32Gb Gddr7 3Xdp 1Xhdmi / 1Tb Ssd Tlc With Dram M.2 2280 Pcie Gen4 Sed Ready / Dell Pro Max Tower T2 With 1500W (80 Plus Platinum) Psu V2 / Windows 11 Pro / 5Yrs Support , System Dell Pro Max Tower T2 / Intel Core Ultra 9 285 (36 Mb Cache, 24 Cores, 24 Threads, 1.9 Ghz To 5.6 Ghz, 65W) / 64Gb: 2 X 32 Gb, Ddr5, 5600 Mt/S, Non-Ecc / Nvidia Geforce Rtx 5070 12Gb Gddr7 3Xdp 1Xhdmi / 1Tb Ssd Tlc With Dram M.2 2280 Pcie Gen4 Sed Ready / Dell Pro Max Tower T2 With 1500W (80 Plus Platinum) Psu V2 / Windows 11 Pro / 5Yrs Support , Software Adobe Creative Cloud All Apps Education Named Subscription License , Software Ai Tools (Google Flow) , Software Davinci Fusion Studio Annual-Commercial , Software Cine Tracer , Software Autodesk Maya Subscription New- Commercial , Software Houdini Academic License , Software Nuke Studio 1-Year Subscription , Laptop Dell Pro Max 16 (Mc16250) Xcto Base / Intel Core Ultra 5 235H, Vpro Enterprise (18Mb, 14 Cores, 14 Threads, Up To 5.00 Ghz Turbo, 45W) / 16Gb: 2X8Gb, Ddr5, 5600 Mt/S, Sodimm, Dual Channel, Non-Ecc / Nvidia C64 Rtx Pro 1000 Blackwell 8Gb Gddr7 / 16 Fhd+ Lcd With 300 Nits, Non- Touch, Fhd Hdr Rgb Camera, Microphone, Wlan / Intel Wi-Fi 6E Ax211, 2X2, 802.11Ax, Bluetooth 5.3 Wireless Card / 512Gb, M.2 2230, Gen4 Pcie Nvme, Ssd, Class 35 / 130W Ac Adapter, Type C (Tco10) / Windows 11 Home / 5Yrs Prosupport Nbd , Smart Tv Smart Tv-32 Inch , Moniters Dell Pro 27 Plus 4K Usb-C Hub Monitor - P2725Qe / 3Y Basic Advanced Exchange Service , Other Equipments Logitech Mk120 Usb Keybord And Mouse , Other Equipments Xp-Pen-Deco01 V3 , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Film Editing - Equipment Requirements , Apple Imac Machines Imac, Apple M4 Chip 10-Core Cpu With 4 Performance Cores And 6 Efficiency Cores 10-Core Gpu Hardware-Accelerated Ray Tracing 16- Core Neural Engine 120Gb/S Memory Bandwidth, 2Tb Ssd, 32Gb Unified Memory, 60.96 Cm (24″) 4.5K Retina Display 4480X2520 Resolution At 218 Pixels Per Inch With Support For 1 Billion Colours With 1-Year Support , Mac Studio M3 Mac Studio, Apple M3 Ultra Chip 28-Core Cpu With 20 Performance Cores And 8 Efficiency Cores 60-Core Gpu Hardware-Accelerated Ray Tracing 32-Core Neural Engine 819Gb/S Memory Bandwidth, 256Gb Unified Memory, 2Tb Ssd, Keyboard & Mouse , Apple Cinema Display 27 Apple Studio Display 5K Retina Display 68.29 Cm / 27 (Diagonal) 5K Retina Display 5120X2880 Resolution At 218 Pixels Per Inch 600 Nits Brightness Support For 1 Billion Colours Wide Colour (P3) True Tone Technology With 1-Year Support , Sennheiser Headphones Hd 280 , Jbl Studio Jbl Monitors/Speakers , External System Connected Ssd External Wd 1Tb Drive , Licenses For Each Software Avid Media Composer Edu 1-Year Subscription New License , Licenses For Each Software Davinci Resolve Software , Licenses For Each Software Fcp Studio , Licenses For Each Software Adobe Premiere Pro Academic License 1-Year Subscription - 3 Nos. , External Backup Hard Drive Wd My Book Backup Drive - 12 Tb , Keyboard/ Mouse Logitech Mk120 Usb Keybord And Mouse , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Audiography - Equipment Requirements , Dubbing/Mixing Room - Hardware And Software Protool Ultimate Edu Subscription For Student/Teacher - New , Dubbing/Mixing Room - Hardware And Software Dolby Atmos Renderer , Dubbing/Mixing Room - Hardware And Software Pace Ilok 3 Usb - C Type , Dubbing/Mixing Room - Hardware And Software Merging Techologies Hapi Mkiii , Dubbing/Mixing Room - Hardware And Software Merging Technologies Ada8V3S 8 Ch Mic/Line Ad&Da 192 Khz , Dubbing/Mixing Room - Hardware And Software Merging Technologies Anubis Pro Sps , Dubbing/Mixing Room - Hardware And Software Avid S1 (Includes 1 Year Hw Warranty) , Dubbing/Mixing Room - Hardware And Software Avid S1 Extended Hw Support - Second Year , Dubbing/Mixing Room - Hardware And Software Avid Dock , Dubbing/Mixing Room - Hardware And Software Focusrite Isa428 Mkii 4-Channel Microphone Preamp , Dubbing/Mixing Room - Hardware And Software Apple Mac Studio M3 Ultra Chip With 28-Core Cpu, 60-Core Gpu, 32-Core Neural Engine, 96Gb Unified Memory, 1Tb Ssd Storage, Macos , Dubbing/Mixing Room - Hardware And Software Applecare+ For Mac Studio (M4 Max / M3 Ultra) , Dubbing/Mixing Room - Hardware And Software Sonnet Rackmac Studio Enclosure - 3U Pro Rackmount Enclosure To Install And Secure One Or Two Mac Studio Computers In A Standard 19-Inch Rack , Dubbing/Mixing Room - Hardware And Software Logic Pro - Professional Music Production , Dubbing/Mixing Room - Hardware And Software Steinberg Nuendo 14 - Software (Standard) , Dubbing/Mixing Room - Hardware And Software Benq 27 Inch 1080P Fhd Ips Monitor|Height Adjustable - 3 Year Warranty (2 Display For Each System) , Dubbing/Mixing Room - Hardware And Software Samsung 65 Tv For Console Room - 1.63 M (65) Crystal 4K Uhd Smart Tv , Dubbing/Mixing Room - Hardware And Software Samsung 55 Tv For Console Room - 1.38 M (55) Crystal 4K Uhd Smart Tv , Dubbing/Mixing Room - Hardware And Software Lg 4K Uhd Hybrid Projector , Dubbing/Mixing Room - Hardware And Software Motorised Projector Screen, 10 X 8 Feet, 150 Diag, 4:3 Aspect Ratio, 1080P-3D-4K With Remote , Dubbing/Mixing Room - Hardware And Software Logitech Mx Keys S Performance Combo - Black (Incl Mx Master 3S, Mx Keys S & Mx Palm Rest) , Dubbing/Mixing Room - Hardware And Software Blackmagic Design Ultrastudio Monitor 3G Sdi/Hdmi Playback Device , Dubbing/Mixing Room - Hardware And Software Thunderbolt 3 Cable (6.6, 40 Gb/S, Active) , Dubbing/Mixing Room - Hardware And Software Usb-C Digital Av Multiport Adapter (1 For Each System) , Dubbing/Mixing Room - Hardware And Software Usb C Hub 10Gbps 6-In-1 Multiport Adapter With 4K@60Hz Hdmi, Type A& C 3.2 Data Ports, 100W Pd For Mac , Dubbing/Mixing Room - Hardware And Software Tt0080831/ Netgear Av Line M4250-12M2Xf 12X2.5G And 2Xsfp+ Managed Switch , Dubbing/Mixing Room - Hardware And Software Izotope Rx 11 Standard , Dubbing/Mixing Room - Hardware And Software Mcdsp Sa2 Dialog Processor , Dubbing/Mixing Room - Hardware And Software Waves Diamond Bundle , Dubbing/Mixing Room - Hardware And Software Fab Filter Mixing Bundle , Dubbing/Mixing Room - Hardware And Software Audio Design Desk Subscription (2 Years) , Dubbing/Mixing Room - Hardware And Software Nugen Loudness Toolkit-2 , Dubbing/Mixing Room - Hardware And Software Sis Edicue , Dubbing/Mixing Room -Mics And Speakers Neumann Ma 1 Monitor Alignment Microphone And Calibration System , Dubbing/Mixing Room -Mics And Speakers Multi-Channel Extension For Neumann Ma 1 System Software , Dubbing/Mixing Room -Mics And Speakers Neumann Kh 150 Dsp Powered Studio Monitor , Dubbing/Mixing Room -Mics And Speakers Height Adjustable Stands For Neumann Kh 150 , Dubbing/Mixing Room -Mics And Speakers Neumann Kh 120 Ii Dsp Powered Studio Monitor (4 For Surrounds & 4 For Tops) , Dubbing/Mixing Room -Mics And Speakers Neumann Lh 32 Wall Mounts With Pan And Tilt (4 For Surrounds & 4 For Tops) , Dubbing/Mixing Room -Mics And Speakers Neumann Kh 870 Ii Dsp Dual 10 Studio Subwoofer , Dubbing/Mixing Room -Mics And Speakers Neumann Kh 310 3-Way Reference Studio Monitors Pair (Left And Right) , Dubbing/Mixing Room -Mics And Speakers Kali Lp 6 (Talk Back Speaker Pair For Recording Booth) , Dubbing/Mixing Room -Mics And Speakers Sennheiser Hd 200 Pro Closed-Back Studio Headphones , Dubbing/Mixing Room -Mics And Speakers Neumann Tlm 103 Stereo Set- Nickel (2 X Tlm 103 Ni + Ea1 In Aluminium Case) , Dubbing/Mixing Room -Mics And Speakers Sennheiser E945 Supercardioid Dynamic Vocal Microphone , Dubbing/Mixing Room -Mics And Speakers Rs-719 Heavy Duty Microphone Boom Stand , Dubbing/Mixing Room -Mics And Speakers Rs-521 Medium Weight Notepad/Lyric Stand , Dubbing/Mixing Room -Mics And Speakers Presonus Hp4 Headphone Annual Periodical Maintenance , Dubbing/Mixing Room -Mics And Speakers Promise Pegasus R4 16 Tb Raid With 3 Years Warranty , Dubbing/Mixing Room -Mics And Speakers Rs T3 Pop Shield , Dubbing/Mixing Room -Mics And Speakers 4-Port Professional Hdmi 4K Automatic Video Switch With Fast Switching , Dubbing/Mixing Room -Mics And Speakers Audio Cables And Connectors (Set) And Testing And Calibration , Dubbing/Mixing Room -Mics And Speakers Audio Rack - Black Color With 7 Pairs L Angle With Screws & Nuts & 15 Amps Power Supply With Side Panel And Heavy Duty Wheels , Dubbing/Mixing Room -Mics And Speakers Active Optical Hdmi Cable 25M , Dubbing/Mixing Room -Mics And Speakers Heavy Duty Cat6 Cable 25M , Dubbing/Mixing Room -Mics And Speakers Usb 2.0 Extender Over Cat5E/Cat6 Cable (Rj45) - Up To 165Ft (50M) - High Speed Usb Port Extender Adapter Kit - Powered , Edit Suite- Hardware And Software Pro Tools Studio Annual Paid Annual Subscription Edu , Edit Suite- Hardware And Software Pace Ilok 3 Usb-C Type , Edit Suite- Hardware And Software Neumann Mt 48 Usb-C Audio Interface , Edit Suite- Hardware And Software Neumann Ndh 20 , Edit Suite- Hardware And Software Neumann Kh 80 Dsp Powered Studio Monitor , Edit Suite- Hardware And Software Apple Mac Mini Apple M4 Chip With 10‑Core Cpu, 10‑Core Gpu, 16‑Core Neural Engine, 32Gb Unified Memory, 512Gb Ssd Storage , Edit Suite- Hardware And Software Applecare+ For Mac Mini (M4) , Edit Suite- Hardware And Software Sonnet Rackmac Mini (2024+) - 2U Enclosure To Mount And Secure Up To Three Mac Minis In A Standard 19-Inch Rack , Edit Suite- Hardware And Software Logic Pro - Professional Music Production , Edit Suite- Hardware And Software Neumann Rime Immersive Binaural Monitoring Plug-In , Edit Suite- Hardware And Software Waves Diamond Bundle , Edit Suite- Hardware And Software Lacie 4 Tb External Hdd Thunderbolt Connected , Edit Suite- Hardware And Software Logitech Mx Keys S Performance Combo - Black (Incl Mx Master 3S, Mx Keys S & Mx Palm Rest) , Edit Suite- Hardware And Software Benq 27 Inch 1080P Fhd Ips Monitor|Height Adjustable - 3 Year Warranty (2 Display For Each System) , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Inter Connection And Storage Equipment Requirements , Storage Centralized Parking Storage For All Departments: Eonstor Gs 3000 G3 3U/16Bay,Cloud-Integrated Unified Storage, Supports Nas, San, Object Protocol And Cloud Gateway, Dual Redundant Controller Subsystem Including 4X12Gb/S Sas Exp. Ports, 4X25Gbe Ports(Sfp28) +4X Host Board Slots,4X16Gb Memory, 2X(Psu+ Fan Module), 2X(Supercap. + Flash Module), 16Xdrive Trays And 1Xrackmount Kit 32X 3.5 Hdd, Sas 12Gb/S, 22Tb, 7200Rpm 3U/16Bay Dual Redundant Controller Expansion Enclosure Including 4X 12Gb Sas Ports, 2X(Psu+Fan Module), 16Xgs Drive Trays, 2X 12G To 12G Sas Cable For Storage Or Expansion Enclosure With 12G Interface And 1Xrackmount Kit 4X 10G Base-Sr Sfp+ Transceiver, Lc, Multi-Mode 3 Years Standard Warranty , Storage Animation Department Blackmagic Cloud Store 80Tb With 1 Year Limited Manufacturers Warranty. , Storage Digital Intermediate Blackmagic Cloud Store 80Tb With 1 Year Limited Manufacturers Warranty. , Interconnection Dell Switch S4148T-On Dell Switch S4148T-On, 1U, 48 X 10Gbase-T, 4 X Qsfp28, 2 X Qsfp+, Io To Psu, 2Xpsu Dell Networking, Qsa Adapter, Qsfp+/Qsfp28 To Sfp/Sfp+/Sfp28 For Select Optics Only (Total-4Nos) Dell Networking, Transceiver, Sfp+, 10Gbe, Sr, 850Nm Wavelength (Total- 4Nos) Dell Networking Cable 100Gbe, Qsfp28 To Qsfp28, Passive Copper Direct Attach Cable, 1 Meter (Total-4Nos) Dell Networking Cable, Om4 Lc/Lc Fiber Cable, (Optics Required), 10 Meter (Total-4Nos) 5 Yrs Pro Support Nbd. , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Cinematography Requirements , Category A: Cameras & Lenses A1. Photography Kit- 1St Year Camera Body- 1St Year Sony A7R5 Body • 61Mp Full-Frame Exmor R Bsi Cmos Sensor • Bionz Xr & Ai Processing Unit • Ai-Based Real-Time Tracking Af System • 8K 24P, 4K 60P, Fhd 120P 10-Bit Video • 4K 16-Bit Raw Output; S-Log3/S-Cinetone • 9.44M-Dot Evf With 120 Fps Refresh Rate • 3.2 4-Axis Multi-Angle Touchscreen Lcd • 10 Fps Shooting With Af/Ae Tracking • 8-Stop 5-Axis Image Stabilization • Dual Cfexpress Type A/Sd Card Slots , Lcd Guard For Sony A7R5 Lcd Panel Guard , Prime Lens 1- 50Mm Sigma 50Mm F1.4 Dg Dn (E-Mount) Or Equivalent • E-Mount Lens/Full-Frame Format, Aperture Range: F/1.4 To F/16 • One Molded Glass Aspherical Element • Three Special Low Dispersion Elements • Super Multi-Layer Coating • Floating System & Large Diameter Design • Hyper Sonic Af Motor • Rounded Nine-Blade Diaphragm • Thermally Stable Composite Material • Brass Bayonet Mount • Compatible With Sigma Usb Dock , Uv Filter For Sigma 50Mm Lens Meco 72Mm Uv Filter , Prime Lens 2 35 Mm Sigma 35Mm F1.4 Dg Dn (E-Mount) Or Equivalent • E-Mount Lens/Full-Frame Format • Aperture Range: F/1.4 To F/16 • Five Sld Elements • One Aspherical Element, Four Hr Elements • Super Multi-Layer Coating • Stepping Motor Af System • Customizable Afl Button • Physical Aperture Ring; De-Click Switch • Rounded 11-Blade Diaphragm • Weather-Sealed Design , Uv Filter Sigma 35Mm F/1.4 Lens Meco 67Mm Uv Filter , Prime Lens 3 85 Mm Sigma 85Mm F1.4 Dg Dn (E-Mount) Or Equivalent • E-Mount Lens/Full-Frame Format • Aperture Range: F/1.4 To F/16 • Five Sld Elements • One Aspherical Element, Four Hr Elements • Super Multi-Layer Coating • Stepping Motor Af System • Customizable Afl Button • Physical Aperture Ring; De-Click Switch • Rounded 11-Blade Diaphragm • Weather-Sealed Desig , Uv Filter Sigma 85Mm F/1.4 Lens Meco 77Mm Uv Filter , Wide Lens 14Mm Sigma 14Mm F1.8 (E- Mount) Or Equivalent • E-Mount Lens/Full-Frame Format • Aperture Range: F/1.8 To F/16 • Three Fld Elements, Four Sld Elements • Four Aspherical Elements • Super Multi-Layer Coating • Hyper Sonic Af Motor, Manual Override • Rounded 9-Blade Diaphragm • Tsc Material, Brass Bayonet Mount , Zoom Lens 1 24-70Mm Sigma 24-70Mm F 2.8 Dg Dn I (E- Mount) Or Equivalent • Full-Frame | F/2.8 To F/22 • Fast & Lightweight Wide-To-Tele Zoom • Hla Autofocus • 6.7 Minimum Focusing Distance • Aperture Ring With Click & Lock Switches • Fld, Sld & Aspherical Elements • Nano Porous & Super Multilayer Coatings • Dust & Splash Resistant , Uv Filter Sigma 24-70Mm Lens Meco 82Mm Uv Filter , Zoom Lens 2 70-200Mm Sigma 70-200Mm F 2.8Mm Dg Dn Os Sport Or Equivalent • E-Mount Lens/Full-Frame Format • Aperture Range: F/1.8 To F/16 • Three Fld Elements, Four Sld Elements • Four Aspherical Elements • Super Multi-Layer Coating • Hyper Sonic Af Motor, Manual Override • Rounded 9-Blade Diaphragm • Tsc Material, Brass Bayonet Mount , Uv Filter Sigma 70-200Mm Lens Meco 82Mm Uv Filter , Telephoto Lens 150-600Mm Sigma 150-600Mm F 5-6.3 Dg Dn Os Sport Or Equivalent • Ef-Mount Lens/Full-Frame Format • Aperture Range: F/5 To F/22 • Two Fld Elements, Three Sld Elements • Super Multi-Layer Coating • Hyper Sonic Motor Af System • Os Image Stabilization • Fixed, Rotating Tripod Collar • Rounded 9-Blade Diaphragm , Uv Filter Sigma 150-600Mm Lens Meco 95Mm Uv Filter , Macro Lens 105Mm Sigma 105Mm F 2.8 Dg Dn Macro Art Or Equivalent • E-Mount Lens/Full-Frame Format • Aperture Range: F/2.8 To F/22 • One Sld Element • Super Multi-Layer Coating • 1:1 Magnification, 11.6″ Min. Focus • Hyper-Sonic Motor Af System • Custom Afl Button, Focus Limiter Switch • Physical Aperture Ring; De-Click Switch • Rounded 9-Blade Diaphragm • Weather-Sealed Desig , Uv Filter Sigma 105Mm F/2.8 Lens Meco 105Mm Uv Filter , Battery Sony Fz100 Battery Or Equivalent ( A7R5 & Fx3A) • Battery Type: High-Capacity Z-Series Rechargeable Lithium-Ion Battery • Voltage / Capacity: 7.2 Vdc / 2280 Mah (16.4 Wh) • Infolithium Feature, Dimensions: Approx. 51.7 × 38.7 × 22.7 Mm (W × H × D) • Weight: Approx. 83 G (3 Ozcompatibility: Supports Dozens Of Sony Cameras Including: O Alpha Series: A1, A1 Ii, A9, A9 Ii, A9 Iii, A7 Iii, A7R Iii, A7R Iv, A7 Iv, A7R V, A7S Iii, A7C, A7 C Ii, A7Cr, A6600, A6700 Cinema/V-Logging: Ilme-Fx3, Zv-E1, Zv-E10 Ii , Battery Charger Sony Dual Charger Bc-Zd1 (A7R5) • Battery Type: High-Capacity Z-Series Rechargeable Lithium-Ion Battery • Voltage / Capacity: 7.2 V / 2280 Mah (16.4 Wh) • Infolithium Support: Displays Remaining Battery Level On Camera Lcd • Compatibility: Sony Alpha Series (E.G., A1 Ii, A9, A7R Iv, A7 Iv, A6600), Zv Series (Zv-E1, Zv-E10 Ii) • Dimensions: Approx. 38.7 × 22.7 × 51.7 Mm (W × H × D) • Weight: Approx. 83 G (3.0 Oz) • Durability & Safety: Built-In Protection Circuitry To Prevent Overcharging/Overheating (Sony Oem) , Category A2. Video Kit Camera Body-1 (2 Year Continuity Project) Sony Fx6 • 4K Full-Frame 10.2Mp Cmos Exmor R Sensor • Dci 4K60P | Uhd 4K120 | 1080P240 • 15+ Stops Of Dynamic Range In S-Log 3 Electrical Installation • 1.3X And 2.0X Anamorphic De-Squeeze • Compact Form Weighs Less Than 2 Lb • Phase Detection Af/Face Tracking/Eye Af • Base 800-12,800 Iso / 320-409,600 Max • S-Cinetone, S-Log3, Hlg Modes • 10-Bit 4:2:2 Xavc-I/16-Bit Raw Output • Dual Cfexpress Type A/Sdxc Card Slots , Camera Body-2 (3Rd Year Song Project) Sony Fx3A • 12.1Mp Full-Frame Cmos Exmor R Sensor • Uhd 4K Up To 120 | 1080P Up To 240 • Compact Form For Cage-Free Operation • 10-Bit 4:2:2 Xavc S-I,16-Bit Raw Output • S-Cinetone/S-Log3/Hlg, 15+ Stops Dr • Detachable 2 X Xlr/Trs Adapter Handle • Phase Detection Af/Face Tracking/Eye Af • 80 To 409,600 Expanded Iso Range • Dual Cfexpress Type A/Sdxc Card Slots , Battery Sony Fz100 Battery , Panel Guard For Sony Fx3A Lcd Panel Guard , Lens Kit 18Mm, 24Mm, 35Mm, 50Mm, 85Mm, And 105Mm (2Nd And 3Rd Year) Dzo Film, Vespid Ii Prime 6-Lens Set Includes 18Mm,24Mm,35Mm,50Mm,85Mm And 105Mm • Full Frame/Vv | T1.9 To T22 Aperture • 18, 24, 35, 50, 85, And 105Mm Primes • Aspherical Element, Reduced Aberrations • 0.8 Mod Gears, 300° Focus Rotation • Cooke /I Technology Metadata • 80Mm Front Outside Diameter • Compact, Lightweight Design • Less Reflective, More Tactile Surface • Color Matched, Common Gearing And Length • Minimal Breathing And Distortion , Gimbal (3Rd Year Song Project) Rs4 Pro Combo • Lightweight Design With 10 Lb Payload • Combo With Focus Pro Motor • Oled Touchscreen With Auto Lock • 2Nd Gen Native Vertical Shooting • Automated Axis Locks • Joystick Or Bluetooth Mode Switching • Supports Wireless Transmitter, Lidar • Teflon-Coated Axes, Activetrack Pro • 13-Hour Operation Time , Battery Sony Bp-U70 Lithium Ion Battery- (Fx6) • Battery Type: Professional Lithium-Ion Battery (Bp-U Series) • Capacity: 72 Wh • Output Voltage: Approximately 14.4 V Dc Nominal (16.4 V Max) • Charging Time: Approximately 150 Minutes Using Sony Bc-U1A/U2A Charger • Compatibility: Select Sony Professional Camcorders Including Pxw-Fs7, Fx6,.. • Dimensions: 41.5 × 84.5 × 69.7 Mm (1.63 × 3.32 × 2.74 In) Weight: Approximately 450 G (15.9 Oz) • Operating Conditions: Discharge: -20 °C To +45 °C (-4 °F To +113 °F); Charge: 0 °C To +40 °C (32 °F To +104 °F) , Battery Charger Sony Dual Battery Charger Bc-U2A Batteries (Fx6) • Battery Compatibility: Supports Sony Bp-U90, Bp- U60, Bp-U60T, And Bp-U30 Lithium-Ion Batteries. • Charging Capacity: Simultaneously Charges Two Batteries, Optimizing Workflow And Reducing Downtime. • Charge Times: Bp-U90: Approximately 190 Minutes. • Ac Input: 100-240 Vac, 50/60 Hz, Suitable For Global Use. • Dc Output: 12 Vdc Via Integrated Cable, Providing 12 V Dc Power Output While Charging One Battery. • Power Output: 12 Vdc At 3 A (36 W) Via Barrel Connector. • Dimensions: 7.0 × 5.4 × 2.1 Inches (177 × 137 × 53.2 Mm). • Weight: 1.4 Lb (620 G). • Operating Temperature: 32 To 113°F (0 To 45°C). • Certifications: Compliant With Iec62368-1 Safety Standard. , Category B: Photography Lights Flash Light 1 Godox V1 Pro S Or Equivalent • Compatible With Sony Adi / P-Ttl • Output: 76Ws • Auto Zoom Control, Zoom Range: 28-105Mm • 2.4 Ghz X Wireless Radio System • Built-In Led Modeling Lamp • Tilts -7 To 120°, Rotates 330° • Round Head, Optional Magnetic Modifiers • 1.5 Sec Recycle Time, Hss Support • Includes Detachable Sub-Flash , Studio Light 1 Godox Ad 600 Pro Or Equivalent • Built-In 2.4 Ghz Wireless X System • Compatible With Most Ttl Systems • 600Ws, 1/256 To 1/1 Power Output • Lithium-Ion Battery Powered • Up To 360 Full-Power Flashes • Flash Duration: 1/220 To 1/10,100 Sec • 1/8000 Sec High-Speed Sync • 0.01-0.9 Sec Recycling Time • 38W Modeling Lamp • Stable Color Temperature Mode , Studio Light 2 Godox Qt 600 Iii Or Equivalent • 600 Ws, 5600K Color Temperature • 0.01-0.9 Sec Recycling • Flash Duration Hss: 1/26,100 Sec • Built-In Wireless X System • 32 Channels, 16 Groups • Optional X1, X2 & Xpro Transmitter • 1/256 To 1/1 Power Range • 40W Led Modeling Lamp , Softbox Octa Softbox Or Equivalent Jenie Beauty Box 105Cm , Light Stand Harison Heavy Light Stand Harison Heavy Light Stand (Set Of 2) , Strip Box Godox Strip Box 35X160 , Beauty Dish Godox W 550 Silver Eauty Dish With Grid Godox Beauty Dish W550 Sliver With Grid (Set Reflector 1 + Grid 1) , Snoot Godox Snoot , Batteries Eneloop 2000Mah Aa Rechargable Batteries (Set Of 4) , Charger Panasonic Bk 3Hcce Aa Charger , Trigger Godox It 30 Trigger With Flash For Sony Works With X Wireless Radio System Compatible With Sony Adi / P-Ttl Frequency: 2.4 Ghz Range: 328 32 Channels; 99 Ids High-Speed, 1St & 2Nd Curtain Sync Runs On Internal Rechargeable Battery Touchscreen Interface Compact & Portable Design Includes Usb-C Cable & Carry Bag , Category C: Camera Accessories (2Nd And 3Rd Year)Tripod-1 Tripod Manfrotto Mt055-X Pro 3 Or Equivalent • Versatile 3-Section Aluminum Tripod • Spreads To Just 3.5 Above The Ground • 63 Max Height • 23.2 Folded Length • Photo/Video Fluid Tripod Head • 15.4 Lb Load Capacity • All-Direction Photo Mode • Pan-And-Tilt Video Mode • Friction Control , Tripod-2 E Image 7080H • Fluid Head With Bowl Size 75Mm. • Plate With Both 1 /4And 3/8Screws , Memory Card Cf Express Type A 240Gb Or Equivalent (A7R5) & Fx6 , Memory Card Angelbird 1Tb Cf Express Type B Or Equivalent (Burano) , Memory Card Sony 480Gb Tough Card Cf Express Type A , Card Reader 1 Sony Mrw-G3 Cf E Type A Card Reader , Card Reader 2 Sony Mrw-G1 Type B Card Reader , Camera Bag Vanguard Veo 49Bf Camera Bag , Hard Case Camera Hard Case (Pelican Type) (Fx6 & Burano) Explore 7635 Hlb Hard Case For Fx6 & Burano , Camera Cage 1 Small Rig Cage For Sony A7R5 Or Equivalent • Formfitting Camera Cage • 1/4-20 & 3/8-16 Accessory Threads • Maintains Access To Cameras Hot Shoe • Arri-Style Locating Handle Included • Built-In Shoe Mounts, Anti-Twist Design • Threads To Mount Optional Accessories • Durable Aluminum Construction , Camera Cage 2 Small Rig Cage For Sony Fx6 Or Equivalent • Camera Top & Side Plates • Quick Release Baseplate • V-Mount Plate With D-Tap Power Cable • Horizontal & Vertical Mounting • 1/4-20 & 3/8-16 Accessory Threads • 3/8-16 Anti-Twist Threads • Durable Aluminum Construction • Baseplate With Folding V-Lock Plate • 15Mm Rod Clamps & 2 X 15Mm Rods , Mattee Box Mattee Box (Fx6 ) • Compact Matte Box Weighing Only 3.8 Oz • Carbon Fiber Box And Top Flag • Includes 4 X 5.65 Filter Tray • Includes 67/72/77/82-95Mm Adapter Rings • Works With Circular Filters Up To 92.5Mm • 2.2 Lb Maximum Load Capacity , Filters H&Y Nd Filters (0.3,0.6 & 0.9) & Uv Filters (Complete Set) • 0.5 To 3.0 Optical Density • Multicoating & Resistance Coating • Schott B270 Optical Glass • Fits 58-77Mm Lens Filter Threads • High-Grade 6063 Aluminum Construction • Size-Adjustable Adapter Ring • Darkens Entire Image Area • Twist To Attach In Seconds , Filters Polariser Filter (Fx6 & Burano) • Minimize Reflections And Glare • Reduces Haze And Blue Cast In Landscapes • Enhances Color And Tonal Saturation • Colorcore Water White Glass , Field Monitor Atomos Shinobi 7 4K Hdmi/Sdi Monitor • 7 1920 X 1200 Touchscreen Display • 4K60 Hdmi 2.0 In/Out, 2K60 3G-Sdi In/Out • 2200 Cd/M² Brightness • Hdmi/Sdi Cross Conversion • 2.5Mm Camera Control Port For Z Cam E2 • Dual Sony L-Series Battery Slots • Atomos; Atomhdr & 3D Lut Support • 10-Stop Dynamic Range • Supports A Variety Of Log Formats , Measuring Laser Distance Meter , Focus Chart , Colour Checker Calibrite Colorchecker Passport Video 2 (Ccppv2) , Cleaning Kit Lens Cleaning Kit (Professional) , Cables 1 Mtr Cable Hdmi To Hdmi , Cables 0.5 Mtr Cable Sdi To Sdi , Cables 5 Mtr Cable Sdi To Sdi , Cables 10 Mtr Cable Sdi To Sdi , Cables 10 Mtr Cable Hdmi To Hdmi , Cables 15 Mtr Cable Hdmi To Hdmi , Category D: Cine-Lineup Cinema Camera (2Nd Year Misc-En & Scene Project) Sony Burano 8K Digital Motion • Compact, Highly Mobile Design • Full-Frame Cmos 8.6K Sensor • 16 Stops Of Dynamic Range • In-Body Image Stabilization|E & Pl Mount • Dual-Base 800/3200 Iso Range • Electronically Variable 0.6-21Nd Filter • Phase Detection Af | Face/Eye Tracking • Full Frame & Super 35 Sensor Modes • Supports Multiple Frame Rates & Codecs • Dual Cfexpress Type B Card Slots , Monitor/ Recorder Shogun Ultra 7 & Recorder • Atomos 11, 12G-Sdi/Hdmi Conversion • 7 1920 X 1080 Touchscreen • Records Up To 8K Apple Prores Raw • Prores Raw + H.265 Dual Recording • Airglu Rf Wireless Sync, Gige, 6E Wi-Fi • 2000 Cd/M² Brightness • Arri/Canon/Red/Sony Camera Sdi Support • Avid Dnx Quicktime • Atomos Remoteview Via Subscription • Optional Ndi 4K Tx Pro Mode 1-Off , Focus System Tilta Nucleus M(Dual Motor) • 1000 Wireless Range • Two Lens Drive Motors • Motors Feature Integrated Receivers • 0.8 Mod Drive Gears • Focus, Iris, Zoom Hand Unit • Motors Daisy-Chain For Power • Right Handgrip With Focus Control • Left Handgrip With Iris And Zoom Control • Hard-Shell Waterproof Case Included , Memory Card Lexar 512Gb Cf Express Type B Card Diamond Series Or Equivalent , Battery Newell V Mount Battery (290 Watts) , Charger Newell V Mount Dual Charger , Lens Kit 8,24,35,50,75, 100Mm Zeiss Nano Prime 6 Lens Kit(18,24,35,50,75,1 00Mm) Set • 18, 24, 35, 50, 75, And 100Mm Lenses • All Lenses Cover Full-Frame Format • T1.5 To T16 Aperture Range • 12-Blade Rounded Iris • Native Lens Data Communication • Zeiss Extended Data • Lens Scale Marked In Feet • Includes Transport Case , 10 &14Mm Laowa Lenses Pl Mount (12Mm Pl Mount Lens) • Full Frame & Vv | T2.6 To T22 Aperture • Zero-D Design, Low-Distortion Optics • 117.8° Fov, 15-Blade Aperture • 16 Elements In 10 Groups • 7.9 Minimum Focusing Distance • 77Mm Filter Thread, 80Mm Front Diameter , Zoom Lens 70-200Mm Zeiss 70-200Mm Cz.2 Lens , Tripod Occnnor 1040 • Tripod: Flowtech 100 Carbon Fiber • Payload Capacity: Up To 45 Lb (20.4 Kg) • Counterbalance: Sinusoidal, Continuously Adjustable • Pan/Tilt Drag: Independent, 9+0 Positions • Tilt Range: +90° To -90° • Tripod Max Height: 60 (152.4 Cm) • Leg Sections: 3, Quick-Release Locks • Floor Spreader: Included • Handle: Pan Handle Included, Attachable Both Sides • Weight: Approx. 12.5 Kg (27.5 Lb) , Camera Cage Tilta Camera Cage For Sony Burano Advanced Kit • Modular Cage For Sony Burano • 15Mm Lws Baseplate, Side Plates • Top Plate, Top Handle, Monitor Mount • Hdmi Cable Clamp, Wi-Fi Tx Bracket • Multiple 1/4-20 & 3/8-16 Threads • Qd Sockets, Shoe Mount, Nato Rails • Side Rosette, 15Mm Rod For Monitor Mount • Aluminum & Stainless Steel Construction , Evf Bracket Rotatable Evf Bracket For Sony Burano Or Equivalent , Tool Kit Tilta Multi Functional Mini Tool Kit • Multi-Functional Mini Tool Kit • Includes 2.5Mm, 3Mm, 4Mm, 3/16 Allen Keys • Flathead & Phillips #2 Screwdrivers, T10 Torx Driver • Aluminum Alloy Frame With Stainless Steel Tools • 3/8-16 And 1/4-20 Threaded Mounts • Compact And Lightweight Design • Integrated Strap Loop For Easy Carry • Color: Titanium Gray • Compatible With Tilta Camera Cages & Support Systems • Portable For Assembly, Disassembly, And On-Set Use , Matte Box Tilta 4X5.6 Carbon Fiber Matte Box Or Equivalent , Adaptor 1 Metabones Pl To E Mount Adaptor , Dry Cabinet Andbon 300 Ltr Dry Cabinet , Light Meter 1 (Common) Sekonic Spectro Master C- 800 Light Meter • Measurement Range: 0.09-18,600 Fc (1-200,000 Lux) • Color Temperature Range: 1600-40,000K • Sensor: High-Resolution Cmos Sensor With 1Nm Increment • Ssi Support: Spectral Similarity Index For Light Matching • Display: 4.3 Color Touchscreen With 11 Display Modes • Cri/Tlci/Tm-30-15: Full Color Rendering Metrics • Flash Measurement: Selectable Shutter Speeds From 1-1/500 Sec • Power: Usb Rechargeable • Connectivity: Usb 2.0 Interface • Dimensions: 73 X 183 X 27 Mm • Weight: 230 G • Included: Carrying Case And Usb Cable , Light Meter 2 (Common) Sekonic Speed Master L858D-U Light Meter • Measuring System: Incident And Reflected Light Metering • Sensor: Spd Sensor • Measuring Range: -5 To 22.9 Ev (Iso 100) • Illuminance Range: 0.1 To 2,000,000 Lux • Iso Range: Iso 3 To Iso 13,107,200 • Shutter Speed Range: 30 Min To 1/80,000 Sec • Display: 2.7 Color Touchscreen Lcd • Flash Measurement: Flash Duration (1/40 To 1/55,500 Sec) • High-Speed Sync (Hss): Supported • Flash Analyzing Function: Yes • Spot Metering: 1° Spot Meter With Viewfinder • Rotating Lumisphere: 270° Rotation, Retractable • Radio Control Modules: Optional For Pocketwizard, Elinchrom/Phottix • Weather Resistance: All-Weather Design • Power: Rechargeable Battery • Dimensions: Approximately 73 X 183 X 27 Mm • Weight: Approximately 230 G , Cine Video Monitor Tv Logic Monitor (Professional Grade) • 1920 X 1080 Resolution Ips Lcd Screen • Composite, 3G-Sdi A/B, Hdmi & Dvi Inputs • Hlg, Pq & Pq2 Hdr Emulation Support • 1 X Composite & 1 X 3G-Sdi Output • 500 Cd/M² Brightness, 178° Viewing Angle • 3.5Mm Audio Headphone Output • Gpi & Ethernet Control • Waveform, Vectorscope, Audio Meter • Focus Assist, H/V Delay, Key Lock, Zoom • Tvlogic Color Calibration Utility & More , Category E: Studio Kit (Common ) Computer Apple Mac Studio M3 Ultra 28 Core Cpu •Apple M3 Ultra 28-Core Cpu •96Gb Unified Ram | 2Tb Ssd •60-Core Gpu | 32-Core Neural Engine •Uhs-Ii Sdxc Card Reader •Wi-Fi 6E (802.11Ax) | Bluetooth 5.3 •6 X Thunderbolt 5 •2 X Usb-A 3.2 Gen 1 | 1 X Hdmi 2.1 •1 X 10 Gigabit Ethernet Port •Macos , Software Final Cut Pro , Software Adobe Psd Annual Subsrciption , Accessories Apple Monitor 27Inch 4K Retina Display , Accessories Apple Keyboard , Accessories Apple Magic Mouse , Accessories Required Cables , Light Controlling Tablet Apple Ipad Pro •13 Ultra Retina Xdr Oled Touchscreen •2752 X 2064 Screen Resolution (264 Ppi) •Apple M4 9-Core Cpu •10-Core Gpu | 16-Core Neural Engine •512Gb Storage | 8Gb Ram •5G Lte | Wi-Fi 6E | Bluetooth 5.3 •Front & Rear 12Mp Ultra Wide Cameras •40 Gb/S Thunderbolt Connectivity •Supports Apple Pencil Pro•Ipados , Display X Lg C3/G3 Oled 65 •Display Type: Qned (Quantum Dot Nanocell Withminiled) •Screen Size: 164 Cm (65 Inches)•Resolution: 3840 X 2160 Pixels (4K Ultra Hd) •Processor: Α7 Ai Processor 4K Gen8 •Color Technology: Dynamic Qned Color With 100%Dci-P3 Coverage •Local Dimming: Advanced Local Dimming Forenhanced Contrast •Hdr Support: Hdr10, Hlg, Dolby Vision •Audio Output: 20W Rms •Audio Technologies: Ai Sound Pro (9.1.2 Channel),Dolby Atmos •Operating System: Webos 2025 With Ai Features •Remote Control: Ai Magic Remote With Ms Copilotintegration •Connectivity: Wi-Fi, Bluetooth, Hdmi, Usb, Ethernet •Voice Assistant: Built-In Google Assistant, Alexasupport •Mounting: Vesa Compatible (300 X 300 Mm) •Dimensions (W X H X D): 1456 X 840 X 29.7 Mm •Weight: 22.5 Kg , Lg 9.1.5 Sound Bar S95Tr (Latest Model) Sound Bar: • Channels & Power: 9.1.5 Configuration With 810 W Total Output And 17 Built-In Speakers •Immersive Audio: Supports Dolby Atmos, Dts:X, Andtriple- Level Spatial Sound For A Cinematic Surroundexperience •Smart Integration: Ai Room Calibration Pro, Woworchestra & Wowcast Enable Seamless Integrationwith Lg Tvs And Wireless Pairing •Connectivity: Includes Hdmi Earc, Hdmi 2.1 Input,Optical, Bluetooth 5.1, Wi-Fi, Usb, Plus Support Forchromecast, Airplay 2, Alexa, And Google Assistant •Setup: Simple Installation Via Power And Single Hdmiconnection With Wireless Rears And Sub; Ideal Formedium-Sized Rooms •Design: Sleek And Low-Profile, Approximately 49.2 ×2.5 × 5.3 Inches (Soundbar); Space-Efficient Setup. , Projector 4K Projector With Screen •Display Technology: 0.65 Dlp •Resolution: 3840 X 2160 Pixels (4K Uhd) •Brightness: 2200 Ansi Lumens •Contrast Ratio: 600,000:1 •Color Gamut: 84% Dci-P3 •Throw Ratio: 0.69-0.83:1 •Zoom: 1.2X Manual Zoom•Focus: Manual •Input Lag: 4.16 Ms (1080P @240Hz) •Hdr Support: Hdr10, Hlg •Audio Output: 5W X 2 Speakers •Audio Features: Earc, Dolby Atmos Passthrough •Operating System: Android Tv (Via Qs02 Dongle) •Streaming Support: Netflix, Youtube, Prime Video,Disney+, Hbo Max, Apple Tv+, Spotify •Connectivity: 2X Hdmi 2.0B, Usb Type-A, Rs232,Audio Out (3.5Mm Mini Jack) •Wireless Features: Wi-Fi 6, Bluetooth 5.0, Googlecast, Apple Airplay •Dimensions: 11 Cm X 30 Cm X 25 Cm •Weight: 3.1 Kg •Power Consumption: 275W (Max), 0.5W (Standby) , Movable Storage 10Tb Desktop External Hdd - Usb 3.0 For Windows And Mac , Ups 1500Va Ups , Computer Speaker 2.1 2.1 Audio Computer Output , Mega Phone Ahuja Bta 550 Wireless Bluetooth Portable 30 Watt Pa • Power Output: 30W Rms • Speaker Configuration: Single 8 Full-Range Dual-Cone Speaker With Tweeter • Microphone Inputs: Two Wired Mic Inputs (4Mv/4.7Kω), One Wireless Mic Input • Auxiliary Input: One Guitar (Aux) Input (100Mv/47Kω) • Tone Controls: Active Bass And Treble Adjustments • Digital Effects: Built-In Digital Echo • Playback Features: Mp3 Player With Bluetooth, Usb, Sd/Mmc Card Support, And Recording Capability • Remote Control: Included For Convenient Operation • Power Sources: Ac Mains, External 12V Dc, Or Built-In 11.1V 2200Mah Rechargeable Li-Ion Battery • Battery Life: Approximately 4 Hours On Battery Power • Construction: Plastic Moulded Cabinet With Trolley System For Portability • With Microphone , Safety Storage Solid Safety Storage To Store Camera With Lock Camera Safety Storage With Door And Lock (14X3X9) (Lxbxh) , Category F: Lighting Equipments , Portable Light Kit • Eight Lights With Charging Case • Output: 396 Lux At 3.3 Per Light • 2000-10,000K Cct; Rgb Color Control • 4.2 X 2.7 Panel; 2-Hour Runtime Battery • Cri 96 | Tlci 96 | Cqs 95 | Tm-30 Rf 94 • Onboard, Dmx/Rdm, Crmx & App Control • Tighter 45° Beam Angle • 0-100% Dimming, 15 Special Effects • 1/4-20 & Magnetic Mounting, Ip65-Rated • Includes Mounting Accessories & Cables , Cine Led Bulb Kit Aputure B7C Bulb Kit (8 Bulbs) • For Studio And Film/Tv Production Output: 328 Lux At 3.3 (120º, 6500K) • 2000 To 10,000K; Rgb Color Control • 23.8 X 1.8 Panel; Ac/Dc Operation • Cri 96 | Tlci 98 | Ssi 74 | Tm-30 94 • Dmx, Crmx, And Sidus Link App Control • Passive Cooling • 2 X 1/4-20 Threads, Infinibar Rail • Clamp To Baby Pin Adapter • Straight Connector Included , Panel Light 1 Aputure Nova P600 C Panel Light • For Studio & Film/Tv Production Output: 17,520 Lux At 3.3 (5600K) • 2000 To 10,000K; Rgb Color Control • 31.6 X 18.96 Panel, Ac/Dc Operation • Cri 95 | Tlci 95 | Ss1 84 | Cqs 95 • On-Board, Dmx512, Bluetooth App Control • Active Fan Cooling • With Control Box, Yoke, Mounting Clamp • Dimming: 0-100°, Plus/Minus Green Adj. • 300+ Gel Presets, 19 Special Effect , Barn Door Aputure Barndoor For P 600 Light P600Rb4 Barn Door For Aputure P600C Or Equivalent , Soft Box Aputure Softbox P 600R23 • For Studio & Film/Tv Production • Output: 98,500 Lux At 3.3 W/ Reflector • 5600K Cct • Ac Or Battery Power • Onboard, Wireless, Dmx & App Control • Art-Net & Lumenradio • Cri 96 | Tlci 96 | Cqs 94 | Ssi 72 • Active Cooling, Weather-Resistant Design • Bowens S Accessory Mount • Includes Remote, Reflector & Rolling Bag , Cine Led Light Godox M 600R Light For Studio & Film/Tv Production Output: 136,000 Lux At 3.3 W/ Reflector 1800-10,000K Cct; Full Rgb Color Control Onboard, Dmx, Crmx & App Control Art-Net & Sacn Ethernet Control Fan Cooled Bowens Mount Ip65 Rated Includes Control Box Includes Power Cable & Soft Case , Cine Light 1 Godox Tl120-K4 Light Four Lights & Remote Control For Wireless Control From Up To 164 Output: 685 Lux At 3.3 For Each Light 2700-6500K Cct; Rgb Mode Onboard, Wireless, Dmx & App Control Cri 96 | Tlci 98 39 Preset Special Effects Built-In Rechargeable Battery; Ac Power Retaining Clip With 1/4-20 For Mounting Includes Adapters, Clips & Hard Case For Wireless Control From Up To 164 Output: 685 Lux At 3.3 For Each Light 2700-6500K Cct; Rgb Mode Onboard, Wireless, Dmx & App Control Cri 96 | Tlci 98 39 Preset Special Effects Built-In Rechargeable Battery; Ac Power Retaining Clip With 1/4-20 For Mounting Includes Adapters, Clips & Hard Case , Cine Light 2 Godox Tl 60-K2 Light Two Lights & Remote Control For Wireless Control From Up To 164 Output: 421 Lux At 3.3 For Each Light 2700-6500K Cct; Rgb Mode Onboard, Wireless, Dmx & App Control Cri 96 | Tlci 98 39 Preset Special Effects Built-In Rechargeable Battery; Ac Power Retaining Clip With 1/4-20 For Mounting Includes Adapters, Clips & Bag Remote Control & Carry Case , High Power Light 1 Godox Mg 120 Arc-Biannual Rate Contract Color Light For Photo, Video, Film & Tv Production 78,800 Lux At 9.8 With Optional Fresnel 2800-6500K Color Temperature Multi-Voltage Ac Power Onboard, Dmx & Lumenradio Crmx Control Bluetooth & 2.4 Ghz Wireless Control 96 Cri, 96 Tlci Fan Cooled, 0-100% Dimming 11 Special Effects, 4 Dimming Curves Compatible With Godox G-Mount Modifiers , High Power Light 2 Godox Mg1200 R Light Compatible With Godox G-Mount Modifiers Green/Magenta Adjustments, 14 Effects Upgraded Optical Technology, Ip65 Rated 78,800 Lux At 9.8 With Optional Fresnel 2800-6500K Color Temperature Multi-Voltage Ac Power Onboard, Dmx & Lumenradio Crmx Control Bluetooth & 2.4 Ghz Wireless Control 96 Cri, 96 Tlci Fan Cooled, 0-100% Dimming 11 Special Effects, 4 Dimming Curves Compatible With Godox G-Mount Modifiers , Storm Light 1 Godox Mg4 K Arc-Biannual Rate Contract Color Light For Studio & Film/Tv Production Output: 640,000 Lux At 3.3 W/ Reflector 2800-10,000K Cct; Green/Magenta Shift Ac Power Onboard, Dmx, Crmx, Ethernet & App Improved Fan Cooling System Compatible With Godox G-Mount Modifiers Upgraded Optical Technology & Ip65 Rated 2.4 Diameter Light Source Emitter Includes Controller & Ac Power Cable , Storm Light 2 Godox Mg 6K Arc-Biannual Rate Contract Color Light For Studio & Film/Tv Production Output: 1,025,000 Lux At 3.3 (5600K) 2800-10,000K Cct; Bi-Color Mode Powered Via Ac Cable & Power Controller Onboard, Dmx, Rdm & Bluetooth Control Cri 97 | Tlci 97 Advanced Air Cooling System G-Mount-Compatible & Includes Yoke Ip65-Rated For Dust & Water Protection , Light Mat 1 Aputure Infinimat 4 X 4 Light Mat • Type: Modular Rgbww Led Light Mat • Size: 4 X 4 Ft • Color Temperature: 2000-10,000K • Color Accuracy: Cri 96, Tlci 97 • Light Engine: Rgbww • Control Box: 1600W, Ac-Powered • Mounting: Multiple Methods Supported • Included Accessories: Inflatable Softbox, Skirt, Control Grid, Head Cable (24.6), Safety Rope • Power Consumption: 800W (Maximum) • Connectivity: Bluetooth (100M Range) , Light Mat 2 Aputure Infinimat 2 X 4 • Type: Modular Rgbww Led Light Mat • Size: 2 X 4 Ft • Color Temperature: 2000-10,000K • Color Accuracy: Cri 96, Tlci 97 • Light Engine: Rgbww • Control Box: 400W, Gold Mount • Power Options: Ac Or Gold Mount Battery • Mounting: Multiple Methods Supported • Included Accessories: Inflatable Softbox, Skirt, Control Grid, Head Cable (24.6), Safety Rope • Power Consumption: 400W (Maximum) • Connectivity: Bluetooth (100M Range) , Light Bar 1 Aputure Infinibar Pb 12 4 Light Kit • Output: 617 Lux At 3.3 (120º, 7500K) • 2000 To 10,000K; Rgb Color Control • 23.8 X 1.8 Panel; Ac/Dc Operation • Cri 96 | Tlci 98 | Ssi 74 | Tm-30 94 • Dmx, Crmx, And Sidus Link App Control • Passive Cooling • 2 X 1/4-20 Threads, Infinibar Rail • 8 X 45º Light Control Grids • Flight Case And 330W Power Adapter , Light Bar 2 Aputure Infinibar Pb6 4 Light • For Studio And Film/Tv Production Output: 328 Lux At 3.3 (120º, 6500K) • 2000 To 10,000K; Rgb Color Control • 23.8 X 1.8 Panel; Ac/Dc Operation • Cri 96 | Tlci 98 | Ssi 74 | Tm-30 94 • Dmx, Crmx, And Sidus Link App Control • Passive Cooling • 2 X 1/4-20 Threads, Infinibar Rail • Clamp To Baby Pin Adapter • Straight Connector Included , Compact Light 1 Amaran F22C Light • For Studio & Film/Tv Production Output: 6420 Lux At 3.3 (5600K) 2500-7500K Cct; Hsi Color Control • 2 X 2 Mat; Ac/Dc Operation • Cri 95 | Tlci 98 | Cqs 96 • On-Board, Dmx, And Bluetooth Control • Passive Cooling For Silent Operation • 0-100% Dimming, 15 Lighting Effects • Multi-Voltage Ac, V-Mount Battery • Includes Softbox Frame, Diffusers & Grid , Compact Light 2 Godox La 300 R Light For Video Production & Vlogging Output: 94,700 Lux At 3.3 W/ Reflector 1800-10,000K Cct; Full Rgb Color Control Ac Or Optional Battery Power Onboard & App Control; Nfc Connection Cri 95 | Tlci 94 14 Lighting Effects Bowens S Accessory Mount, Black Housing Includes Reflector Includes Power Adapter , Compact Light 3 Godox La 150 R Light For Video Production & Vlogging 165W Fixture 1800-10,000K Cct; Full Rgb Color Control Ac Or Optional Battery Power Onboard & App Control; Nfc Connection Cri 95 | Tlci 94 14 Lighting Effects Bowens S Accessory Mount Includes Reflector Includes Power Adapter , Panel Light 2 Godox Ldx 100 R Light For Video Production And Vlogging Output: 4620 Lux At 3.3 (5600K) 2500-10,000K Cct; Rgb Color Control 18 X 16; Ac/Dc Operation Cri 96 | Tlci 96 Onboard, Wireless & App Control 0-100% Dimming, 14 Lighting Effects Optional Remote Control & Barndoors Includes Diffuser Includes Power Supply & Carry Case , Panel Light 3 Godox Ldx 50 R Light For Video Production And Vlogging Output: 2340 Lux At 3.3 (5600K) 2500-10,000K Cct; Rgb Color Control 14 X 12; Ac/Dc Operation Cri 96 | Tlci 96 Onboard, Wireless & App Control 0-100% Dimming, 14 Lighting Effects Optional Remote Control & Barndoors Includes Diffuser Includes Power Supply & Carry Case , Cine Light Kit Aputure Storm 80C- 3 Light Kit Or Equivalent For Video Production And Vlogging Output: 2340 Lux At 3.3 (5600K) 2500-10,000K Cct; Rgb Color Control 14 X 12; Ac/Dc Operation Cri 96 | Tlci 96 Onboard, Wireless & App Control 0-100% Dimming, 14 Lighting Effects Optional Remote Control & Barndoors Includes Diffuser Includes Power Supply & Carry Case , Professiona L Light 1 Godox P 1200 R Hard P8 / Arri Sky Panel-X 21 Or Equivalent • Type: Modular Rgbacl Led Panel • Color Temperature Range: 1,500-20,000K • Color Accuracy: Cri ≥99, Tlci ≥93 • Light Output: 16,602 Lux At 3.3 (1M) • Panel Size: 2X1 (29.1 X 13.3 Inches) • Pixel Zones: 8 Independent Zones • Control Options: Wired (Dmx-512), Wireless (Bluetooth Via Lico App, Lumenradio) • Cooling: Passive/Active With Ip66 Rating • Power Supply: Integrated Psu; Daisy-Chainable With Other Skypanel X Units • Mounting: Tool-Less Frame With Quick-Lock System • Compatibility: All S60-C Accessories Via Optional Adapter • Included Accessories: X21 Dome, Manual Yoke, Mains Cable , Hard Light Godox P 1200 R Hard / X21 Hard Light For Arri Sky Panel Or Equivalent P8 X21 Hard Light For Arri Sky Panel Or Equivalent , High Power Light Godox P 1200 R Hard P 8 For Studio & Film/Tv Production Output: 129,200 Lux At 3.3 (5600K) 1800-10,000K Cct; Rgb Color Control 29.2 X 15.2 Panel | Ac Power Cri 96 | Tlci 98 Onboard, Dmx/Rdm, Crmx & App Control Improved Fan Cooling System Flicker-Free Operation Ip65-Rated Weather Resistance Includes Yoke & Ac Power Cable , Dido Lights Godox Ms 600R 2K / Dido Lights Light , Category G: Light Accessories Spotlight Mount 1 Godox Vsa-26 K Spotlight Attachment Projectionlight Kit , Spotlight Mount 2 Godox Vsa-36K Kit Spotlight Attachment Kit , Iris 18 X Godox Vsa-Id Spotlight Mount 36 , Gobo Kit Godox Vsa-Gs1 Gobo Kit , Fresnel 1 Godox Fls 5 Fresnel , Fresnel 2 Godox Fls 10 Fresnel , Barn Door Godox Lb-02 , Light Dome 1 Godox Qr-P 90 T Light Dome , Light Dome 2 Godox S 65 T Light Dome Mini , Light Dome 3 Godox Qr-P 150 T Light Dome , Light Dome Godox Cs 85D Lantern 120 , Light Dome Godox Gp 5 Light Dome , Lantern Godox Cs 85 D Lantern , Reflector Kit Reflector Kit (For 1200X & 1000C) Or Equivalent , Cf12 Fresnel Godox Fls 10 Fresnel , Spotlight Max 1 Godox Gp 36 K Spotlight , Spotlight Max 2 Spotlight Max 50 (For 1200X,1000C,Xt 26) Or Equivalent , Iris Max 18 Godox Gp-Id Iris , Gobo Kit Godox Gobo Kit Godox Gp-Gs1,2,3,4,5 , F14 Fresnel Godox Gf 14 Fresnel , Beam Kit Storm Parallel Beam 70 Kit With Flight Case Or Equivalent , Cf16 Fresnel Cf16 Fresnel With Flight Case Or Equivalent , Stand 1 Dearkol Mfe 5800 (Expandable Up To 17Ft Height & 62Kg Payload) Or Equivalent , Stand 2 Dearkol Mfd 6000 (Expandable Up To 20Ft And 82Kg Payload) Or Equivalent , Soft Box Godox P 1200 Rh Do Softbox , Mounting Rig Godox P 1200 Rh Ad Mounting Rig , Lights Dimmer 5K Dimmer , Skimmer Cloth 10X10 Skimmer Cloth , 12 X12 Skimmer Cloth , 10X10 Black Cloth , 12 X12 Black Cloth , 10X10 Green Cloth , 12 X12 Green Cloth , Backgroung For Photography , Safety Storage For Lights Camera Safety Storage With Door And Lock (14X3X9) (Lxbxh) Stainless Steel 0.8Mm, Thickness (Jindal Ss) , Category H: Light Grip Equipments C Stand Godox 270Cs Stand , Par Stand 1 Par Stand Double Height , Par Stand 2 Par Stand Triple Height Or Equivalent , Black Flags 1 4X4 Black Flags Or Equivalent , Black Flags 2 2X1 Black Flags Or Equivalent , Empty Frames 4X4 Empty Frames Or Equivalent , Boom Rods Boom Rods (Various Sizes) Or Equivalent Boom Rods : Stand Height 6Ft To 10Ft, Extension Rod 5 Ft To 10Ft. , Arm Rods Arm Rods (Various Sizes) Or Equivalent , L Rods L Rods (Various Sizes) Or Equivalent , Sand Bag Sand Bag (Professional Grade) Or Equivalent , Skimmer Frame 1 6X6 Skimmer Frames Or Equivalent , Skimmer Frame 2 10X10 Skimmer Frames Or Equivalent , Skimmer Frame 3 12X12 Skimmer Frames Or Equivalent , Grid 1 Honey Comb Grid 6X6 Or Equivalent , Grid 1 Honey Comb Grid 10X10 Or Equivalent , Grid 1 Honey Comb Grid 12X12 Or Equivalent , Loop Boards Loop Boards (Various Sizes) Or Equivalent Solid Wooden Loop Boards (Various Sizes) 20Mtrs 6Pin Socket 2Nos With Led Indicator And A Tripper-15 Nos; 10Mtrs Board With 6Pin Socket 4 Nos With Switch, Led Indicator And A Tripper- 10 Nos; And 20Mtrs Board 6Pin Socket 6Nos With Switch, Led Indicator And A Tripper-5 Nos. , Track System Track & Trolley Full Kit 40Feet Length Manuall 150 Bowl Height 100Kg Capacity With Head , Slider Slider 10Ft Full Kit Or Equivalent , Low Base Stands Low Base Stands , Stand For 100 Bowl Head , Stand For 150 Bowl Head , Cutter Stand , Grip Heads Grip Heads (Professional Grade) , Reflector Board Reflectors 4X4 Board , Low Board , Apple Box Apple Box Setup (Complete Set) Apple Box Setup 20X12X8, 20X12X4, 20X12X2 ,20X12X1 (Complete Set) , Stool Setup Stool Setup 1 Feet , Stool Setup Stool Setup 2 Feet , King Pole- Wall To Wall Mount King Pole (6Ft To 12Ft) , Light Clamps Light Clamps (Various Sizes) , Hydraulic Stand Hydraulic/Windup Stand , Category I: Television Production , Video Camera Sony Hx Z 200 Camera , Mixer Yamaha Mg10X Mixing Console Audio Mixer - Xlr Input/Output, Phono Jack, Level Meter , Recorder Zoom H8 Recorder , Tripod Small Rig Ad80 Carbon Tripod Model No:4163 , Mic And Accessories Sennheiser Lapal Microphone With Cable , Mic And Accessories Rode Boom Pole , Mic And Accessories Rode Ntg4 Mic , Mic And Accessories Rode Blimp , Cables Monitoring Head Phone, Video/Audio Cables And Connectors , Mac Imac, Apple M4 Chip 10-Core Cpu With 4 Performance Cores And 6 Efficiency Cores 10-Core Gpu Hardware-Accelerated Ray Tracing 16- Core Neural Engine 120Gb/S Memory Bandwidth, 512Gb Ssd, 24Gb Unified Memory, 60.96 Cm (24″) 4.5K Retina Display 4480X2520 Resolution At 218 Pixels Per Inch With Support For 1 Billion Colours, Keyboard & Mouse , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Manpower Deployment , Cost For Deployment Of System Administrator For One (1) Year
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Contract Date: Apr 18, 2026 Contract Value : 41,286
Government Departments No of Bidders 1
Uttar Pradesh View Result →
14.
Educational and Research Institute #10734365 AOC
Notice Inviting Etender For Procurement Of Equipment, Instruments, Machineries, Tools Charts Etc. Related To Laboratories And Workshop Of Engineering Institute For Junior Executives, Dalalpukur, Howrah-711104-1 Dead Weight Pressure Gauge Tester • Bourdon Tube Pressure Gauge As Manometer • Manometer With Transparent Scale • Manufactured From Corrosion Resistant Materials • Components Arranged On Base Plate. • Set Of Weights • Medium For Transmitting Pressure: Hydraulic • Capacity Of 25Kg / Cm2 • The System Is Nickel Chrome • The Weights Are Zink Iron ) 2 Cut Section Model Of Hermetically Sealed Compressor 3 Universal Bevel Protractor ( Accuracy: 0.01 Mm Material: Stainless Steel Diameter: 70 Mm Size: 300 Mm Type: Analog Graduation 5 Min Straightness .00016+ ( .00005Xl / 2 ) ) 4 Cut Section Model Of Lamont Boiler 5 Slip Gauge Set; Special Set ( M87 ) , Grade I, High Grade Steel, 9 Mm Wide & 30-35 Mm Long Cross Section. 6 Utm Machine ( Material:Ms Voltage:220 V Phase: Single Phase Capacity: 10 To 100 Ton Cross Travel: Up To 1000 Mm Weight: 1500 Kg ) 7 Mollier Chart Flex ( 40 × 30 ) 8 Teak Wood; Wood For Pattern Shop Size: 2×1×6 9 Thermal Conductivity Of Metal Rod; • Frame: Made Of M.S. Square Tubes & Sheets, Welded & Powder Coated • Optional Accessories: Rotameter For Water Flow Measurement • Electric Heater : Clamp Heater, Capacity 200 W, Supply 230 V Ac • Insulation Jacket: Made Of Mild Steel, Mild Steel Rod Is Insulated By Asbestos Powder • Diameter Of Metal Rod 25 Mm, Length Of Rod 300 Mm 10 Cut Section Model Of Screw Type Rotary Air Compressor 11.01 Chart Of Velox Boiler With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.02 Chart Of Mollier Diagram With Labelling ( Size: 23’’ X 36’’, Material: Pvc, With Roller ) 11.03 Chart Of T-T-T Diagram With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.04 Chart Of Utm Machine & Sample With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.05 Chart Of Torsion Testing Machine With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.06 Chart Of Iron-Carbon Equilibrium Diagram With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.07 Chart Of Vernier Caliper With Labeling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.08 Chart Of Vernier Height Gauge With Labeling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.09 Chart Of Thread Measurement With Labeling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.10 Chart Of Gear Tooth Vernier Caliper With Labeling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.11 Chart Of Hermetically Sealed Compressor With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.12 Chart Of Domestic Refrigerator With Labeling ( Size:30× 40, Material: Pvc, With Roller ) 11.13 Chart Of Full Pressure Engine Lubricating System With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.14 Chart Of Constant Mesh Gear Box With Labeling ( Size:30× 40, Material: Pvc, With Roller ) 11.15 Chart Of Synchromesh Gear Box With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.16 Chart Of Components Of A Chasis With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.17 Chart Of Knuckel Joint With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.18 Chart Of Intersection Of A Prism And Cone ( Size:30× 40, Material: Pvc, With Roller ) 11.19 Chart Of Projection Of A Straight Line In Different Quadrants ( Size:30× 40, Material: Pvc, With Roller ) 11.20 Chart Of Plummer Block - Details And Arrangement ( Size:30× 40, Material: Pvc, With Roller ) 11.21 Chart Of Centrifugal Pump With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.22 Chart Of Balanced Type Vane Pump With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.23 Chart Of Bent Axis Piston Pump With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.24 Chart Of Lathe Machine With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.25 Chart Of Single Point Cutting Tool Geometry With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.26 Chart Of Screw Jack Assembly With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.27 Chart Of Cotter Joint Assembly And Design With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.28 Chart Of Vertical Drilling Machine With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.29 Chart Of Shaper Machine With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.30 Chart Of Safety On A Lathe Machine ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.31 Chart Of Safety On A Milling Machine ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.32 Chart Of Safety On A Shaper Machine ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.33 Chart Of Safety In Carpentry Shop ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.34 Chart Of Safety In Fitting Shop ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.35 Chart Of General Precaution In Workshop ( Size:30× 40, Material: Pvc, With Roller ) 11.36 Chart Of Cnc Turning With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.37 Chart Of Elements Of Jigs ( Drill Bushes ) With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.38 Chart Of Tig Welding With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.39 Chart Of Mig Welding With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.40 Chart Of Engine Cooling System With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 12 Digital Lab Trainer ( Bread Board Model ) ( Built-In Dc Regulated Power Supply; At Least 8 Logic Input Switches; At Least8 Output Led; Pulse Generator For Clock Frequency ; Patch Chords ) 13 Arduino Uno Board ( Atmega328 ) 14 Experimental Kit To Study Pam, Pwm And Ppm Modulation And Demodulation ( Pulse Generator With Variable Frequency And Amplitude, Pam Modulator And Demodulator, Pwm Modulator And Demodulator, Ppm Modulator And Demodulator ) 15 Ujt Trainer Kit With P.S. & Patch Cord 16 Led Colour Tv Demonstration Kit ( Display Type: Led, Hd: Screen Size: 24: Connectivity: Usb, Hdmi, Av: Test Points To Be Present Minimum 10 Nos.: Switched Faults To Be Provided: Product Tutorial Should Be Present ) 17 Microwave Oven Demonstration Trainer Kit ( Type: Solo: Capacity: 17 Ltr.: Control Type:Mechanical: All Circuits & Panels To Be Mounted On-Board: Test Points To Be Provided To Analyze Signals: Instruction Manual To Be Provided ) 18 Washing Machine Demonstration Trainer Kit ( Application: Lab Experiment: Semi-Automatic: Tank Capacity: 6.5 Kg: Block Diagram & Circuit Diagram To Be Mounted On The Lid: Test Points To Be Provided ) 19 Mobile Communication Trainer Kit To Study Various Signalling And Fault Insertion Techniques ( Gsm Handset Trainer Kit.  Operate Both On Windows And Linux Platform  Usb Interface For Communication  Best Suitable For Iot Gateway Application  External Connector To Interface With Any Microcontroller  Easy Understanding Of At Commands  Real Time Operation  Built In Network Status Led  Audio Interface Connector  Simple / Easy Operation  External Antenna  Application Module Relay Interface For Ac Device ( Optional ) ) 20 Trainer Kit For Mobilephone Set To Study Transmitter And Receiver Sections In Mobile Handset And Measure Frequency Band Signal ( Real Time Mobile Operation # Full Understanding Of Mobile Phone Working # Frequency Measurement And Band Verification # Provides Study Of All Sections In Mobile Phone # Tx / Rx Frequency Measurement # 3G / 4G Technology And Gmsk Signals # Gsm Data Rate # Detail Study Of User Interface Control Signals # Detail Study Of Sim Operation # Battery Identification And Charging Study  Switched Faults 21 Consumable ( 9V Battery, Cro Probe, Digital Ics ) 22 Cro ( 20 Mhz , Dual Trace, Dual Channel ) 23 Trainer Kit For Mobile Phone ( Features : The Experimental Kit Will Be Capable I ) To Study General Block Diagram Of A Mobile Phone. Ii ) To Study Mobile Transmission Section. Iii ) To Study Mobile Reception Section. Iv ) To Study Different Nos. Of Faults Provided With The Trainer. V ) To Study & Observe Voltages / Waveforms Of Each Test Points. Vi ) To Study Mobile Charging Circuits. Vii ) To Use Mobile Phone As Modem For Using At Commands As Given; A ) Sending Text Messages, Read / Delete Massages Etc. B ) Calling To A No, Reject / Accept The Incoming Calls Etc. C ) Gprs Related Commands. Study Of Bluetooth Technology & Connection With Other Bt Devices. Bluetooth Profiles : Bip, Bpp, Dunp, Ftp, Hid, Opp , Sap, A2dp, Pbap, Spp Etc. To Study General Idea Of Sim Card. ( Local Sim Card Must Be Inserted By The User At The Time Of Experiment ) . ) 24 Salt Bath Furnace For Heat Treatment ( • Resistance Heating ( Element ) • Operating Temp.: Up To 1200°C • Digital Temp. Controller ( Pid ) • Chamber Size : 450Mm X 300 Mm X 300 Mm • Furnace Uniformity + / - 2°C • Temp Recorder With 2 Channel Placed At Opposite Sides • Salt For Use With Two Times Top Up • Spare Heating Element 2Pc ) 25 In-Situ Metallography Kit ( • Items: Portable Grinder / Polisher, Grinding Discs, Lapping Cloths, Diamond Pastes, Aerosol Spray, Replication Film, Paste, Reflector And Gumming Tape For Excellent Contrast Or Transparent Replica - Film Thickness - 125 Microns, 30 Microns, Replica Liquid, Glass Slides ) 26 Automatic Electrolytic Polishing Machine ( • Function: Fully Automatic Electrolytic Polishing And Etching With Automatic Scanning Function • Preparation Time: Within 30 Sec • Electrolyte For Low / High Alloyed Steels & Aluminium • Pump And Magnetic Stirrer • Integrated Cooling System ) 27 Micro-Hardness Tester ( • Test Load : 10, 25, 50, 100, 200, 300, 500, 1000 Gm • Scale: Knoop & Vickers • Dwell Time: 5-90 Seconds Settable • Objectives : 10X, 20X, 40X, 60X • Loading And Unloading : Motorized • Measurement – Automatic And Or With Manual Micrometer Eyepiece. • Traverse: Automatic And Or Manual With Micrometer. • Focusing - Motorized Focusing With Manual Over-Ride • Computerized Imaging Attachment, Dedicated Software To Measure Hardness On Computer With Report Generation Facility • Accessories: Sheet Holder, Wire Holder, Hardness Test Block, Bulb, Indenter. ) 28 Cracked Aluminum Test Block ( For Penetrant Sensitivity Checking In Dpt ) ( Aluminum Test Piece That Measures 3 X 2 X 3 / 8 With A 1 / 8 Wide With A Milled Notch That Separates The Blocks Two Sides To Facilitate Side-By-Side Penetrant Comparison. The Test Block Is Used To Check The Strength Of “In-Use” Penetrants. This Is Done By Processing One Half Of The Block With “Used” Penetrant, And The Other Half With Fresh Penetrant. Can Be Used To Compare Sensitivity Of Different Penetrants Or Sensitivity Of New And Old Penetrants. Complies With Astm E165 And Asme Boiler And Pressure Vessel Code Section V & Iii, And Mil-I-23135-C. ) 29 Pie Gauge / Magnetic Flux Indicator ( To Be Made From Eight Ferrous Segments, Braised Into A Single Piece, Providing A Star Pattern Of Nonferrous Discontinuities. Eight Linear Discontinuities To Provide Indications In All Directions Non-Ferrous Handle With Pivot. Specification Compliance • Mil-Std-271 • Astm E709 ) 30 20Mhz Analog Cro ( Dual Trace ) , Bandwidth:- Dc ~ 20Mhz ( -3Db ) Y Deflection:- 5Mv / Div ~ 10V / Div. Rise Time:- <18Ns,Mag _70Ns :17.5Ns. Max Input:- 400V ( Dc+Acp-P ) 31 50Mhz Digital Storage Oscilloscope, Bandwidth 50Mhzreal-Time Sampling Rate 500 Msa / S, Equivalent Sampling Rate 50Gsa / S.Memory Depth: 32Kptstrigger Types: Edge, Pulse Width, Video, Slope, Alternativeunique Digital Filter Function And Waveform Recorder Function, Max Input:- 400V ( Dc+Acp-P ) 32 3D Model Showing Different Parts Of A Coal Fired Thermal Power Station 33 3D Model Showing Different Parts Of A Gas Fired Thermal Power Station 34 3D Model Showing Different Parts Of A Diesel Power Station 35 3D Model Showing Different Parts Of A Nuclear Power Station 36 3D Model Showing Different Parts Of A Hydro-Electric Power Station 37 3D Model Of Boiler Showing Its Different Parts Used In Coal Fired Thermal Power Station 38 3D Model Of Boiler Showing Its Different Parts Used In Nuclear Power Station 39 3D Model Of Water Turbine Showing Its Different Parts, Used For Hydro-Electric Power Plant 40.1 Colour Flex Chart Describing Different Parts Of A Coal Fired Thermal Power Station Size:30× 40, Material: Pvc, With Roller 40.2 Colour Flex Chart Describing Different Parts Of A Gas Fired Thermal Power Station Size:30× 40, Material: Pvc, With Roller 40.3 Colour Flex Chart Describing Different Parts Of A Diesel Power Station Size:30× 40, Material: Pvc, With Roller 40.4 Colour Flex Chart Describing Different Parts Of A Nuclear Power Station Size:30× 40, Material: Pvc, With Roller 40.5 Colour Flex Chart Describing Different Parts Of A Hydro-Electric Power Station Size:30× 40, Material: Pvc, With Roller 40.6 Colour Flex Chart Describing Different Parts Of Boiler, Used In Coal Fired Thermal Power Station Size:30× 40, Material: Pvc, With Roller 40.7 Colour Flex Chart Describing Different Parts Of Boiler, Used In Nuclear Power Station Size:30× 40, Material: Pvc, With Roller 40.8 Colour Flex Chart Describing Water Turbine Showing Its Different Parts, Used For Hydro-Electric Power Plant Size:30× 40, Material: Pvc, With Roller 41 3-Phase Induction Motor Speed Control Using Pwm Inverter For Interpreting Speed-Torque Characteristics Using Vvvf Drive 42 Ups Trainer Kit ( 1Kva ) Output Voltage : 230 V Ac Nominal, Input Voltage : +12V Dc Battery. Capacity : 1Kva, Output Frequency : 50 Hz Accuracy : + 5%. Switching : Automatic. 43 Smps Trainer Kit Incl. ±5V, ±12V Input Voltage: Ac 100 – 264V 50 / 60Hz Output Voltage: 12V Dc, 0-5A Output Voltage: Adjustment Range: ±20% Protections: Overload / Over Voltage / Short Circuit Auto-Recovery After Protection Universal Ac Input / Full Range 100% Full Load Burn-In Test Cooling By Free Air Convection High Quality And High Performance Led Power Supply With A Metal Body For Hidden Installation For Led Lighting Design With Built-In Emi Filter, Improve Signal Precision. Certifications: Ce & Rohs No Minimum Load. Compact Size Light Weight. High Efficiency, Reliabiltiy & Low Energy Consumption Controller: Satandard 44 Commutation Kit Of Scr ( Class A To F ) Completely Self – Contained Stand – Alone Unit. Demonstrates The Principle And Various Methods Of Forced Commutation Of Scr. 1. Self-Commutation By Resonating Load ( Class “A” Method ) . 2. Self-Commutation By An L C Circuit ( Class “B” Method ) . 3. Complimentary Commutation ( Class “C” Method ) . 4. Auxiliary Commutation ( Class “D” Method ) . 5. External Pulse Commutation ( Class “E” Method ) . * Supply Required 230V, 50Hz Ac. * Built-In Ic Based Dc Regulated Supply And Led Indication For Supply “On”. * Built-In Load Facility In The Form Of Led’S. * Connecting Each Circuit Separately And Verifying Its Principle. * Multicoloured Test Points Are Provided To Observe The Waveform And Voltages. * Set Of Required Number Of Patch Cords. * Housed In An Elegant Cabinet With A Well Spread Intelligently Designed Circuit Layout Engraved On The Front Panel. * Strongly Supported By A Comprehensive Instruction Manual Complete With Theory And Operating Details. 45 Colour Flex Chart Describing Single Line Diagram Of A Given Distribution System ( Lt & Ht ) Size:30× 40, Material: Pvc, With Roller 46 Colour Flex Chart Describing Short Transmission Line ( 220Kv ) Size:30× 40, Material: Pvc, With Roller 47 Colour Flex Chart Describing Medium Transmission Line ( 220Kv ) ( Both T & Π-Model ) Size:30× 40, Material: Pvc, With Roller 48 Power Factor Improvement Kit Using Static Condenser Including Load R-L Load Of At Least 2Kva With Appropriate Capacitor Bank. 49 Setup For Load Test On 1-Ph Induction Motor: Load Test Kit Of 1-Ph Induction Motor ( 1Hp, 230V, 50Hz ) 50 Loading Test Kit Of 3-Phase Alternator: ( 2Kw, 415V, 50Hz ) With 3-Ph R-L Load Box Coupled To A Dc Motor; Capable To Perform As Synchronous Motor Test With Dc Generator Load; Integrated With All Required Measuring Instruments 51 Speed Control Kit Of Stepper Motor Including Reversing Arrangement With 8051 Microcontroller: Stepper Motor Of Appropriate Capacity To Be Served By 8051Μc 52 Speed Control Kit Of Ac Servo Motor: Motor Spec: 3000Rpm, 200W, 0-240V, Control Torque: Standard With All Needed Accessories 53 Speed Control Kit Of Dc Servo Motor: •Voltmeter Vdc 3.5 Digit. 200Mv •Rpm Indicator For Speed Measurement •Voltmeter Vdc 3.5 Digit 20V Power Supply: •Ic Regulation In Controller Circuit Power Supplies •Operated On Mains Power 230V, 50Hz +10% Features: •Position Control Of A 12 Volt, 1 Amp Dc Geared Pm Motor ( 50 / 60 Rpm ) •Calibrated Dials With 1 Degree Resolution For Reference And Output Position •Two 360 Degree Servo-Potentiometers •Built In Step Signal •Built In Waveform Capture / Display Card For Study Dynamic •Electronic Techogenerator For Feedback •Non-Contact Eddy Current Break For Load •Speed Control Of 12V, 4W, Permanent Magnet Dc Motor •Speed Range Up To 3000 Rpm ( Typical 54 Mcb Test Kit For Performing Load Test: Kit Should Be Able To Perform Short-Circuit, Over Load, Thermal Trip Test For Mcb With Rating Upto 30A 55 Dismantled Elcb & Rccb Kit For Demonstration Purpose: Elcb: Single Phase 2 Pole Elcb, Rccb, Isi Marked 32A Mcb With High Voltage, Overload Protection, Current 3 To 30 Ma Rccb: Breaking Capacity 10 Ka, Frequency, 50 Hz, Number Of Poles 2P, Operating Characteristics: Ac Rated Current 40 A, Sensitivity 30 Ma, Standard, Is 12640-1 & Iec 61008-4, Test Button Yes 56 Testing Kit For Percentage Differential Protection Of Transformer Using Transformer Differential Relay ( Electromagnetic / Μp Based / Static ) : Standard For Laboratory Purpose 57 Colour Flex Chart Describing Different Parts Of Acb & Vcb ( 33Kv, 15Mva ) : Size:30× 40, Material: Pvc, With Roller 58 Experiment Kit To Measure Solar Radiation Using Pyranometer On Tilted Surface At Different Angle Inclination: Standard For Laboratory Purpose 59 Colour Flex Chart Describing Different Parts Of Solar Flat Plate Collector & Solar Concentrating Collector & Trough Collector: Size:30× 40, Material: Pvc, With Roller 60 Experiment Kit To Measure Thermal Performance Of Solar Water Heating System: Standard For Laboratory Purpose 61 3D Model Describing Different Parts Of ( I ) Solar Street Lighting System & ( Ii ) 1Kw Small Wind Turbine ( Swt ) : 3D Model For Laboratory Purpose 62 Setup Of 250Wp Solar Pv Plant Including All Accessories: Solar Panel Specifications:Peak Power: 250W; Maximum Power Voltage: 20.2V; Maximum Power Current: 12.38A; Open Circuit Voltage: 23.9V; Short Circuit Current: 13.12A; Power Allowance Range: + / - 3% Hybrid Inverter Specifications: Nominal Battery Voltage: 12V; Continuous Power Output: 1000W / 1000Va; Surge Power: 2000Va Output Voltage: 230V Ac; Output Frequency: 50Hz / 60 Hz; Output Waveform: Pure Sine Wave; Maximum Solar Input Power: 600W; Maximum Open Circuit Solar Input Voltage: 55V; Maximum Solar Charging Current: 50A; Maximum Mains Ac Charging Current: 20A; Maximum Combined Charging Current: 50A; Peak Efficiency: 93% Battery Specifications ( Per Battery ) : Nominal Voltage: 12V; Nominal Capacity: 50Ah ( 10H Rate ) / 55Ah ( 20H Rate ) ; Maximum Charging Current: 25A; Self-Discharging Rate: <3% Per Month; Cycle Lifetime At 30% D.O.D.: 1000-1100 Pressure Control: Safety Valve Installed Terminal Type: F13 ( Bolts And Washers Included ) Operating Temperature: From +10C To +40C 63 Setup Of Small Wind Turbine Plant Including All Accessories: Standard For Laboratory Purpose 64 Study Kit Of Assembling And Dismantling Of Csp Plant Using Parabolic Trough Or Disc: Standard For Laboratory Purpose 65 Study Kit For Assembling Vertical Axis Or Horizontal Axis Swt: Standard For Laboratory Purpose 66 Digital Lcr Multimeter: Digital Lcr Meter ( Battery Operated ) , Model: 4070 Range: 0.1Μh To 20H, 0.1Pf To 2000Μf, 0.1Ohm To 20Mohm Accuracy: 2Mh, Resolution: 1Uh, Accuracy: 20Mh, Resolution: 10Uh, Accuracy: 200Mh, Resolution: 100Uh Accuracy: 2Nf, Resolution: 1Pf, Accuracy: 20Nf, Resolution: 10Pf, Accuracy: 200Nf, Resolution: 100Pf, Accuracy: 2Uf, Resolution: 1Nf, Accuracy: 200, Resolution: ± ( 0.8 Percent+5 ) 0.1, Accuracy: 2K, Resolution: 1, Accuracy: 20K, Resolution: 10, Accuracy: 200K ( Make: Metravi ) 67 Handheld Power Meter Or Power Analyzer With Socket: Voltage: 85V-265V, Current; 0.002A~20A, 50Hz, 1-Ph 68 Analog Power Factor Meter ( 1-Ph & 3-Ph ) : Standard For Laboratory Purpose 69 Multimeter With Clamp Meter Arrangement With Hfe Lcr: Standard For Laboratory Purpose ( Make: Metravi ) 70 Three Phase Power Measurement Kit ( Y & Δ Load R-L Load ) Incl. 3-Ph Wattmeter With 2Kw Range: Standard For Laboratory Purpose 71 Kit For Troubleshooting Single Phase Electronic Energy Meter: 230V, 1-Ph, 50Hz 72 Three Phase Trivector Meter: Salient Features Class 0.5S As Per Relevant Is And Iec Standards 5A Current Rating 3 Phase 4 Wire 4 Quadrant Measurement Anti-Tamper Features Self-Diagnostic Capability Multiple Tariff / Time Of Day Feature Bidirectional Energy Recording Up To 4 Maximum Demand Registers Load Survey ( Interval Data ) Features Up To 12 Reset Backups Optical Port / Rs 232 / Rs 485 / Ir / Irda / Rf ( 2.4 Ghz / 865-867 Mhz ) ( Optional ) ( Make: L&T ) 73 Brake Test Kit Of Dc Series Motor: 220V Dc, 2Hp With Allied Required Accessories 74 Back-To-Back Test Kit Of Single Phase Transformer: 1-Ph, 240V, 50Hz, 1Kva ( 2 Nos. ) Identical Transformers With Other Standard Accessories 75 Isolation Transformer Kit: 230V; 230V / 10Amp 230V; 230V / 5Amp 76 Pulse Transformer Kit: Dc Supply: Two 5V & 12V, Pulse Generator: Two Selectable Frequency & Variable Pulse Width, Mains: 230V / 50Hz, Adequate For Cro Observations, Optocoupler: One, One Ferrite Wired 1:1 77 Colour Flex Chart Describing Different Vector Groups Of Theree Phase Transformer: Size:30× 40, Material: Pvc, With Roller 78 Full-Wave Fully Controlled Bridge Rectifier Kit With & Witout Filter Arrangement: Standard For Laboratory Purpose 79 Kit To Find The Characteristics Of Zener Diode: Standard For Laboratory Purpose 80 Kit To Find The Characteristics Of Mosfet: Standard For Laboratory Purpose 81 Ujt Relaxation Oscillator Trainer Kit: Standard For Laboratory Purpose 82 Singlestatge Transistor Trainer Kit ( Ce-Mode ) : Standard For Laboratory Purpose 83 Trainer Kit For Sr, D, Jk & T – Flip-Flop: Standard For Laboratory Purpose 84 Trainer Kit For Realization Of Encoder And Decoder Circuit: Standard For Laboratory Purpose 85 Trainer Kit For Realization Of Multiplexer And Demultiplexer Circuit: Standard For Laboratory Purpose 86 Trainer Kit For Implementing Dac & Adc: Standard For Laboratory Purpose 87 Connector Cables For Ade Lab. Of Different Types: Standard For Laboratory Purpose 88 Arduino Uno R3 Board With Lcd1602, Servo Motor, Relayes, Processing And C Code, Beginner Starter Kit With Mannual And Allied Accessories: Standard For Laboratory Purpose 89 Trainer Kit For 8051 Μc Programming: Trainer Kit For 8051 Μc Programming With Keypad To Write Program 90 Trainer Kit Using 8051 Μc For Measurement Of Ac Voltage, Current, Frequency & Phase Angle Using Suitable Ct, Pt, Zcd, Adc, Etc. 91 Demonstration Kit For Identifying Pvc, Xlpe, Vir, Catenary, Frls, Frlsh Cables / Wires Of Different Current Rattings: Standard For Laboratory Purpose 92 Megger: Insulation Tester ( 500V ) With Hand-Driven Gen.: 500V, 2500 Mega Ohms 93 Megger: Insulation Tester ( 2500V ) With Hand-Driven Gen. 2.5Kv, 2500 Mega Ohms 94 3-Ph Smart Energy Meter For Lt Power Measurement, 3-Ph, 415V, 4-Wire, Kwh Meter, Current: 10-60A, Class 1.0 Accuracy As Per Relevant Is And Iec Standards, With Lcd Display [ Make: L&T ] 95 Trainer Kit For Dc Chopper Drive With Resistive Load & Dc Separately Excited Motor. 1 / 8 Hp, 200Vdc Operation, Current Limit Protection, Speed Control Using Frequency And Duty Cycle Variation, Jones Chopper Based Control, Motor Loading Arrangement Can Be Provided / Resistive Load May Be Connected, Other Variety Of Controllers With Converter Control With Closed Loop Controller 96 Trainer Kit For Controlling The Speed Of Separately Excited Dc Motor By Changing The Firing Angle Of Scr Using 1-Ph Full Converter. Power Supplies: • Power Supply +15Vat 150Ma • Isolated Supply 0-220V At 5A. • Operated On Mains Power 230V, 50Hz +10% Digital Meters: • Voltmeter 2000V Ac • Voltmeter 2000V Dc • Ammeter 2A Dc Components Are Mounted On The Panels Are: • Scr Tyn604 ( 2 Nos. ) • Diode 1N5408 ( 2Nos. ) • Diode Ba159 • Ac Phase Control By Gate Control Firing Circuit. • Snubber Circuit. Load: • 1 / 2Hp Dc Shunt Motor. • Inductor As Load 230V, 1A • Lamp Load 230V, 60W 97 Μcontroller Based 3-Ph Syn. Motor Drive: Trainer Kit For Controlling The Speed Of Synchronous Motor ( 1Kva ) Drive Using Μc. 98 Demonstartion Kit Showing Different Types Of Power Semiconductor Devices With Heat Shink E.G. Scr, Igbt, Gto, Mosfet, Standard For Laboratory Purpose. 99 Kit For Magnetic Control Of Im: Control And Power Circuit For ( I ) Forward And Reverse Rotation Of Squirrel Cage Im Using Contactor, ( Ii ) Automatic Star-Delta Starter Of Squirrel Cage Im, ( Iii ) Dynamic Braking Of Squirrel Cage Im, Standard For Laboratory Purpose. 100 Screw Driver Set, Standard For Laboratory Purpose. 101 6” Slide Range, Standard For Laboratory Purpose. 102 Wire Stripper, Standard For Laboratory Purpose. 103 Crimping Tool ( 1 Sq. Mm. To 6 Sq. Mm. ) . 104 2.5 Sq. Mm. Stranded Pvc Copper Wire 105 1.5 Sq. Mm. Stranded Pvc Copper Wire 106 1 Sq. Mm. Stranded Pvc Copper Wire 107 Soldering Kit: 20W With Solder Material 108 Contact Type Tachometer ( Range: 0-10, 000 Rpm ) 109 Set-Up With Different Type Tl Lamps ( Conventional & Led ) With Fittings Containing Electrimagnetic Ballast / Electronic Ballast Etc.: Tl Fittings With: 1. Electronic & Electromagnetic Ballast For ( I ) Single 40W, 240V, 50Hz Tl, ( Ii ) 2X40w, 240V, 50Hz Tl, 2. 20W Led Tl With Fittings Incl. 110 3-Ph Capacitor Bank Of 2-4Kva For Correcting Power Factor Of 415V, 50Hz, 1500 Rpm, 2Hp, 3-Ph Squirrel Cage Im With Facility To Connect The Stator Of The 3-Ph Im Both In Star & Delta Mode And A Tri-Vector Meter Having Facility To Measure Kw, Kva, Kwh, Kvarh, Pf. 111 Transformer Oil Breakdown Strength Kit: Breakdown Strength Kit With 5 Ltr. Fresh Transformer Oil, Standard For Laboratory Purpose. 112 Chart For Demonstration Of Different Fire Extinguishers: Colour Flex Chart Describing Different Types Of Fire Extinguishers ( 4 X 3 ) , Material: Pvc, With Roller 113 Chart For Demonstration Of Artificial Respiration ( Cpr ) And Prepare A Report.: Colour Flex Chart Describing Different Types Of Artificial Respiration ( Cpr ) ( 4 X 3 ) , Material: Pvc, With Roller.
Contract Date: Dec 10, 2024 Contract Value : 11.21 Lakh
Government Departments No of Bidders 3
West Bengal View Result →
15.
Youth Affairs and Sports and Culture #10721205 Price Bid
Rate For First-Aid & Consumables Items 2025 , Item Wise Boq 15.0 Boq_Ver3.0 Item Wise Normal Inr Only Inr Select, Excess (+), Less (-) Tender Inviting Authority: Director Sports And Youth Welfare, T.T. Nagar Stadium Bhiopal Name Of Work: Rate For First-Aid & Consumables Items 2025 Contract No: Name Of The Bidder/ Bidding Firm / Company : Price Schedule (Domestic Tenders - Rates Are To Given In Rupees (Inr) Only) (This Boq Template Must Not Be Modified/Replaced By The Bidder And The Same Should Be Uploaded After Filling The Relevant Columns, Else The Bidder Is Liable To Be Rejected For This Tender. Bidders Are Allowed To Enter The Bidder Name And Values Only ) Number # Text # Text # Number # Text # Number Number Text Text # Number # Text# Text # Number # Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number # Number # Text Text Number # Number # Date Number # Number # Text # Sl. No. Product Name & Specification Item Code / Make Quantity Units Estimated Rate In Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion Against Each Item Quoted Currency In Inr / Other Currency Basic Rate In Figures To Be Entered By The Bidder In Rs. P Excise Duty Amount In Inr Rs. P Gst Amount In Inr Rs. P Freight Charges ( Unloading & Stacking) In Rs. P Any Other Taxes In Rs. P Any Other Duties/Levies In Rs. P Less For Cenvat Credit,If Any Respect Of Supplies Under Full Excise Duty Category Name Of Manufacturer/ Brand Total Amount Without Taxes In Rs. P Total Amount With Taxes Col (14) = Sum (8) To (13) In Rs. P Total Amount In Words , Firstaid & Consumables , Arm Sling , Shoulder Immobilization Sling , Shoulder Support With Movement Limitation , Clavicle Support , Adjustable Abduction Shoulder Support , 15-Degree Abduction Shoulder Support , 45-Degree Abduction Shoulder Support , Elastic Elbow Support , Elbow Support With Silicone Pads , Elastic Elbow Support With Pads , Epicondylitis Elbow Strap , Elbow Mobilization Orthosis , Wrist And Forearm Immobilization Support , Wrist Support , Carpal Tunnel Wrist Support , Thumb Support , Soft Cervical Support , Cervical Immobilization Collar , Posture Correction T-Shirt , Back Orthosis For Vertebral Extension , Taylor Brace For Hyperkyphosis , 4-Point Spinal Hyperextension Brace , Flexible 4-Point Spinal Hyperextension Brace , Abdominal Support Bandage , Basic Lumbar Stabilizing Support , Economical Lumbar Support , Lumbar Support With Massage Pad , Lumbar Stabilizing Support , Lumbar Orthosis With Tension Straps , Adjustable Lumbar Stabilizing Support , Sacroiliac Stabilizing Brace , Maternity Support Belt , Hip Joint Orthosis (Hip) , Hip Joint Orthosis (Thigh) , Elastic Knee Support - Basic , Elastic Knee Support - Top Silicone Band , Elastic Knee Support - Steel Spiral , Elastic Knee Support - Open Patella , Patella Support Knee Brace , Elastic Knee Support With Patellar Ring , Patellar Tendon Support , Patellar Lateralization Knee Support , Patellar Tendon Pain Relief Knee Brace , Physiological Knee Orthosis , Short Functional Knee Brace , Long Rigid Knee Brace (4-Point) , Short Knee Brace With Rom Limit , Short Functional Knee Brace , Rigid Acl Brace With Hinges , Rigid Acl Brace With Hinges - Comfort , Dynamic Pcl Knee Brace , 4-Point Acl/Pcl Knee Brace , Hyperextension Knee Brace , Lightweight Oa Knee Brace , Oa Knee Brace With Wrap , Soft Oa Knee Brace With Rom , 4-Point Oa Knee Brace , Pcl Immobilisation Brace , Universal Knee Immobilizer , Compression Ankle Support , Silicone Ankle Support , Elastic Ankle Support With Strap , Achilles Tendon Support With Silicone Pad , Elastic Achilles Tendon Support , Foam-Gel Ankle Brace , Lace-Up Ankle Brace , Adjustable Ankle-Foot Drop Brace , Standard Walker Boot , Rom Adjustable Walker Boot , Fixed Walker Boot , Pneumatic Air Walker Boot , Silicone Foot Support - Heel Soft , Silicone Foot Support - Insole , Toe Spreader , Forefoot Cushion , Performance Elbow Support , Performance Lumbar Support , Performance Knee Support For Soft Tissue Compression , Sporty Ankle Support , Shoulder Immobilization Brace - Kidz , Knee Immobilization Brace - Kidz , Wrist Immobilization Brace - Kidz , Ankle Foot Immobilization Brace - Kidz , Ankle Orthosis For Stabilisation - Kidz , Orthopedic Insole - Sport , Orthopedic Insole - Comfort , Orthopedic Insole - Comfort Pro , Orthopedic Insole - Carbon , Anti-Embolism Calf Stocking , Anti-Embolism Thigh Stocking , Anti-Embolism Thigh Stocking With Waist Attachment , Surgical Compression Calf Stocking White , Surgical Compression Thigh Stocking White , Surgical Compression Calf Stocking Brown , Surgical Compression Thigh Stocking Brown , High Compression Calf Stocking White , High Compression Thigh Stocking White , High Compression Calf Stocking Brown , High Compression Thigh Stocking Brown , Adjustable Lower Leg Compression Wrap , Adjustable Ankle Foot Compression Wrap , Premium Adjustable Lower Leg Compression Wrap , Premium Adjustable Upper Leg Compression Wrap , Adjustable Arm Compression Sleeve , Adjustable Hand Compression Wrap , Waist To Mid-Thigh Compression Garment , Breast To Ankle Compression Garment , Breast To Knee Compression Garment , Breast To Mid-Thigh Compression Garment , Waist To Thigh Compression Garment , Breast To Thigh Compression Garment , Compression Belt , Compression Bra , Digital Wrist Blood Pressure Monitor , Digital Upper Arm Blood Pressure Monitor , Digital Upper Arm Blood Pressure Monitor (Bluetooth) , Digital Upper Arm Blood Pressure Monitor On Arm (No Hose/Cable) , Digital Upper Arm Blood Pressure Monitor With Ecg Function , Glucometer With Strips , Body Composition Monitor , Bmi Scale , Ankle Tens , Knee And Elbow Tens , Digital Tens/Ems Unit , Digital Tens/Ems Device With Heat , Menstrual Relax , Foot Massager , Footbath Massager , Facial Sauna , Clinical Thermometer , Ear Thermometer , Non-Contact Thermometer , Hearing Amplifier , Heated Under Blanket , Electric Blanket , Back & Neck Heating Pad , Steam Vapouriser , Nebulizer , Ir Lamp - 100W , Ir Lamp - 150W , Ir Lamp - 300W , Ir Lamp Replacement Bulb - 100 W , Ir Lamp Replacement Bulb - 150 W , Air Purifier - 26Msq , Air Purifier - 54Msq , Air Purifier - 106Msq , Yoga Strech Mat - With Vibration & Heat , Infrared Massager , Physio Gun , Pulse Oximeter , Analogue Weighing Scale , Digital Weighing Scale , Hypervolt Go 2 , Hypervolt 2 Pro , Hypervolt 2 , Normatec 3 Leg Package - Standard , Normatec Premier , Normatec Go , Normatec 3 Hip Attachment , Normatec Arm Attachment , Vyper 3 Eu , Hypersphere Mini Black , Hypersphere Black , Venom 2 Back , Venom 2 Leg , Venom Go , Venom 2 Right Shoulder , Venom 2 Left Shoulder , Venom Pod Shoulder Right , Venom Pod Shoulder Left , Heated Hypervolt Head Attachment , Hypervolt Charger Head Eu/Usa/India , Hypervolt Head Attachments , Hypervolt Case , Hypervolt Go 2 Charging Dock , Hypervolt 2 Charging Dock , Hypervolt 2 Pro Charging Dock , Hypervolt Eva Case Black One Size , Venom Go Case , Venom Go Refill Pack , Normatec Carry Case , Hyperice Carry Case (Normatec) , Pulse Carry Case Black One Size (Normatec) , Normatec 3 Backpack , Theragun Elite , Theragun Prime Plus , Theragun Pro Plus , Theragun Relief , Theragun Sense , Theragun Mini , Theragun Mini 2.0 , Theraface Pro , Therabody Recoverytherm Cube , Therabody Hot And Cold Knee , Achedaway Mini Scraper , Achedaway Heated Muscle Scra , Achedaway Cupper , Achedaway Cupper Duo , Compex Sp 5.0 , Compex Sp 8.0 , Game Ready Grpro 2.1 , Mueller Revive™ M4 , Mueller Revive™ M2 , Portable Heat, Cold, Contrast & Compression Therapy Machine (Mueller Therm X) , Mueller Therm X Garments Each , Clx Loop Red , Clx Loop Green , Clx Loop Blue , Clx Loop Black , Clx Loop Silver , Clx Loop Gold , Resistance Loop 12” - Red , Resistance Loop 12” - Green , Resistance Loop 12” - Blue , Resistance Band – Very Light – 1.5 Mtr (Yellow) , Resistance Band – Light – 1.5 Mtr (Red) , Resistance Band – Medium – 1.5 Mtr (Green) , Resistance Band – Heavy – 1.5 Mtr (Blue) , Resistance Band – Extra Heavy – 1.5 Mtr (Black) , Resistance Band – Super Heavy – 1.5 Mtr (Silver) , Resistance Band – Maximum Resistance – 1.5 Mtr (Gold) , Active Recovery Kit Eu/La Beginner , Active Recovery Kit Eu/La Adv , Resistance Band – Very Light – 5.7 Mtr (Yellow) , Resistance Band – Light – 5.7 Mtr (Red) , Resistance Band – Medium – 5.7 Mtr (Green) , Resistance Band – Heavy – 5.7 Mtr (Blue) , Resistance Band – Extra Heavy – 5.7 Mtr (Black) , Resistance Band – Super Heavy – 5.7 Mtr (Silver) , Resistance Band – Maximum Resistance – 5.7 Mtr (Gold) , Yellow Tubing Thera-Band 25Ft , Red/Medium Thera-Band Tubing 25Ft Disp Box , Green/Hvy Thera-Band Tubing 25Ft Disp Box , Blue/Ext Hvy Thera-Band Tubing 25Ft Disp Box , Black/Special Hvy Thera-Band Tubing 25Ft Disp Box , Silver/Super Hvy Thera-Band Tubing 25Ft Disp Box , Yellow Tubing 100 Ft , Red Tubing 100 Ft , Green Tubing 100 Ft , Blue Tubing 100 Ft , Black Tubing 100 Ft , Silver Tubing 100 Ft , Yellow Tubing W/Soft Handle , Red Tubing With Soft Handle , Green Tubing With Soft Handle , Blue Tubing With Soft Handle , Black Tubing With Soft Handle , Silver Tubing With Soft Handle , Resistance Tubes Light Retail , Resistance Tubes Heavy Retail , Red Tubing Loop W/Padded Cuff , Green Tubing Loop W/Padded Cuff , Blue Tubing Loop W/Padded Cuff , Black Tubing Loop W/Padded Cuff , Rehab And Wellness Station , Door Anchor , Accessories Kit , Assist Strap , Sports Handle , Exercise Handle , 18/45Cm Yellow Exercise Ball , 22/55Cm Red Exercise Ball , 26/65Cm Green Exercise Ball , 30/75Cm Blue Exercise Ball , 33/85Cm Silver Exercise Ball , Pro Series Gym Ball Yellow , Pro Series Gym Ball Red , Pro Series Gym Ball Green , Pro Series Gym Ball Blue , Mini Ball Yellow , Silver Stability Disc 13” , Blue Stability Trainer , Green Stability Trainer , Black Stability Trainer Inflate , Rocker Board , Wobble Board , Flexbar-Yellow , Flexbar-Red , Flexbar-Green , Flexbar-Blue , Finger Flexion Exercise Disc Red , Finger Flexion Exercise Disc Green , Finger Flexion Exercise Disc Blue , Finger Flexion Exercise Disc Black , Finger Flexion Xtrainer Assorted Disc Pack , Yellow Hand Exerciser Ball , Red Hand Exerciser Ball , Green Hand Exerciser Ball , Blue Hand Exerciser Ball , Black Hand Exerciser Ball , Tan Soft Weight Ball (0.5Kg) , Yellow Soft Weight Ball (1Kg) , Red Soft Weight Ball (1.5Kg) , Green Soft Weight Ball (2Kg) , Blue Soft Weight Ball (2.5Kg) , Black Soft Weight Ball (3Kg) , Red Ankle Weight - 1 Kg Pair (0.5Kg Each) , Green Ankle Weight - 1.4 Kg Pair (0.7Kg Each) , Blue Ankle Weights - 2.2 Kg Pair (1.1Kg Each) , Shoulder Pulley , Stretch Strap , High Resistance Band Light And Medium (Color: Orange And Green) , High Resistance Band Medium And Heavy (Color: Green And Blue) , High Resistance Band Heavy And X Heavy (Color: Blue And Purple) , Digi-Flex Hand Exercisers - Tan, Xx-Light - Finger (0.75 Lbs) / Hand (2.5 Lbs) , Digi-Flex Hand Exercisers - Yellow, X-Light - Finger (1.5 Lbs) / Hand (5.0 Lbs) , Digi-Flex Hand Exercisers - Red, Light - Finger (3.0 Lbs) / Hand (10.0 Lbs) , Digi-Flex Hand Exercisers - Green, Medium - Finger (5.0 Lbs) / Hand (16.0 Lbs) , Digi-Flex Hand Exercisers - Blue, Heavy - Finger (7.0 Lbs) / Hand (23.0 Lbs) , Digi-Flex Hand Exercisers - Black, X-Heavy - Finger (9.0 Lbs) / Hand (31.0 Lbs) , Digi-Flex Hand Exercisers - Silver, Xx-Heavy - Finger (11.0 Lbs) / Hand (38.0 Lbs) , Digi-Flex Hand Exercisers - Gold, Xxx-Heavy - Finger (13.0 Lbs) / Hand (45.0 Lbs) , Digi-Flex Hand Exercisers - Set Of 5 (Yellow, Red, Green, Blue, Black), No Rack , Digi-Flex Hand Exercisers - Set Of 5 (Yellow, Red, Green, Blue, Black), With Metal Rack , Digi-Flex Hand Exercisers - Set Of 8 (Tan, Yellow, Red, Green, Blue, Black, Silver, Gold), No Rack , Digi-Flex Hand Exercisers - Set Of 8 (Tan, Yellow, Red, Green, Blue, Black, Silver, Gold), With Metal Rack , Mvp Balance System, 10-Ball Set (2 Each Yellow - Black), No Rack , Plastic Adjustable Multi Slant And Calf Stretcher Board , Finger Weights, Multicolor, Set Of 10 , Wobble Ball, 18 , Pronation/Supination Wrist Exercise Wheel , Gel-Hand Exercise Balls - 6-Piece Set (Tan Through Black) , 360 Stick Vibration Exerciser , Inflatable Exercise Sensi-Ball - Orange - 22 (55 Cm) , Inflatable Exercise Sensi-Ball - Green - 26 (65 Cm) , Inflatable Exercise Sensi-Ball - Red - 30 (75 Cm) , Inflatable Exercise Sensi-Ball - Blue - 34 (85 Cm) , Inflatable Exercise Sensi-Ball - Red - 39 (95 Cm) , Inflatable Exercise Saddle Roll (Peanut Gym Ball) - Yellow - 16 Dia X 35 L (40 Cm Dia X 90 Cm L) , Inflatable Exercise Saddle Roll (Peanut Gym Ball) - Orange - 20 Dia X 39 L (50 Cm Dia X 100 Cm L) , Inflatable Exercise Saddle Roll (Peanut Gym Ball) - Green - 24 Dia X 43 L (60 Cm Dia X 110 Cm L) , Inflatable Exercise Saddle Roll (Peanut Gym Ball) - Red - 28 Dia X 47 L (70 Cm Dia X 120 Cm L) , Inflatable Exercise Saddle Roll (Peanut Gym Ball) - Blue - 32 Dia X 51 L (80 Cm Dia X 130 Cm L) , Inflatable Exercise Sensi-Saddle Rolls - Yellow - 16 Dia X 35 L (40 Cm Dia Cm X 90 Cm L) , Inflatable Exercise Sensi-Saddle Rolls - Orange - 20 Dia X 39 L (50 Cm Dia X 100 Cm L) , Inflatable Exercise Sensi-Saddle Rolls - Green - 24 Dia X 43 L (60 Cm Dia X 110 Cm L) , Inflatable Exercise Straight Rolls - Yellow - 16 Dia X 35 L (40 Cm Dia X 90 Cm L) , Inflatable Exercise Straight Rolls - Orange - 20 Dia X 43 L (50 Cm Dia X 100 Cm L) , Inflatable Exercise Straight Rolls - Green - 24 Dia X 53 L (60 Cm Dia X 110 Cm L) , Donut Ball - Yellow - 18 Dia X 10 H (45 Cm Dia X 25 Cm H) , Donut Ball - Orange - 22 Dia X 12 H (55 Cm Dia X 30 Cm H) , Donut Ball - Green - 26 Dia X 14 H (65 Cm Dia X 35 Cm H) , Donut Ball - Red - 30 Dia X 16 H (75 Cm Dia X 40 Cm H) , Donut Ball - Blue - 34 Dia X 18 (85 Cm Dia X 45 Cm H) , Theraputty Standard Exercise Putty, 6 Piece Set (Tan, Yellow, Red, Green, Blue, Black), 4 Oz , Val-U-Putty Exercise Putty, 6 Piece Set, 1 Lb. , Power-Web - 14 - Level 1 - Tan , Power-Web - 14 - Level 2 - Yellow , Power-Web - 14 - Level 3 - Red , Power-Web - 14 - Level 4 - Green , Power-Web - 14 - Level 5 - Blue , Power-Web - 14 - Level 6 - Black , Power-Web Combo - 14 - Level 1 & 3 - Tan/Red , Power-Web Combo - 14 - Level 2 & 4 - Yellow/Green , Power-Web Combo - 14 - Level 3 & 5 - Red/Blue , Power-Web Combo - 14 - Level 4 & 6 - Green/Black , Power-Web Jr - 7 - Level 2 - Yellow Junior , Power-Web Jr - 7 - Level 3 - Orange Junior , Power-Web Jr - 7 - Level 3 - Red Junior , Power-Web Jr - 7 - Level 4 - Green Junior , Double Massage Ball 8Cm*16Cm , Spiky Massage Ball 6Cm , Spiky Massage Ball 7Cm , Spiky Massage Ball 8Cm , Spiky Massage Ball 9Cm , Spiky Massage Ball 10Cm , Lacrosse Foot Massager Ball - 60Mm , Lacrosse Foot Massager Ball - Peanut Roller Plain 15Cm , Lacrosse Foot Massager Ball - Peanut Roller Spiky 15Cm , Acupressure Hemisphere Massage Ball - 8Cm , 8 Hand Pump , Manual Compression Therapy Wrap Knee , Manual Compression Therapy Wrap Elbow , Manual Compression Therapy Wrap Ankle , Manual Compression Therapy Wrap Wrist , Rigid Ankle Immobilization Walker Long , Rigid Ankle Immobilization Walker Short , Semi-Rigid Ankle Immobilization Walker Long , Semi-Rigid Ankle Immobilization Walker Short , Bunion Correction Splint , Instant Hot Pack, Disposable - 5 X 7 Case Of 24 , Instant Hot Pack, Disposable - 4.5 X 9 Case Of 24 , Instant Hot Pack, Disposable - 6 X 9 Case Of 24 , Instant Cold Pack, Disposable (5.5 X 7) , Reusa/Eu/Australiable Hot/Cold Gel Pack (14Cm X 18 Cm) , Reusa/Eu/Australiable Hot/Cold Gel Pack With Adjustable Brace , Reusa/Eu/Australiable Hot/Cold Foot Ice Pack Hot Cold Therapy , Cotton Crepe Bandage 6 Cm X 4 Mtr , Cotton Crepe Bandage 8 Cm X 4 Mtr , Cotton Crepe Bandage 10 Cm X 4 Mtr , Cotton Crepe Bandage 15 Cm X 4 Mtr , Iv Cannula Fixator 4.5 Cm X 6 Cm , Plaster Of Paris Bandage 7.5 Cm X 2.7 Mtr , Plaster Of Paris Bandage 10 Cm X 2.7 Mtr , Plaster Of Paris Bandage 15 Cm X 2.7 Mtr , Plaster Of Paris Slab 10 Cm X 60 Cm , Plaster Of Paris Slab 15 Cm X 75 Cm , Plaster Of Paris Slab 15 Cm X 100 Cm , Cast Padding 10 Cm X 3 M , Cast Padding 15 Cm X 3 M , Adhesive Hospital Tube 2.5 Cm X 8 M , Adhesive Hospital Tube 5 Cm X 8 M , Adhesive Hospital Tube 7.5 Cm X 8 M , Adhesive Hospital Tube 10 Cm X 8 M , Adhesive Hospital Tube Classic 2.5 Cm X 9 M , Adhesive Hospital Tube Classic 5 Cm X 9 M , Adhesive Hospital Tube Classic 7.5 Cm X 9 M , Adhesive Hospital Tube Classic 10 Cm X 9 M , Adhesive Tape Spool 1.25 Cm X 1 M X 1 Spool , Adhesive Tape Spool 2.5 Cm X 1 M X 1 Spool , Adhesive Tape Spool 2.5 Cm X 5 M X 1 Spool , Adhesive Tape Spool 5 Cm X 5 M X 1 Spool , Adhesive Tape Spool 7.5 Cm X 5 M X 1 Spool , Adhesive Tape Spool 10 Cm X 5 M X 1 Spool , Microporus Hypoallergenic Non Woven Tape 1.25 Cm X 9 Mtr , Microporus Hypoallergenic Non Woven Tape 2.5 Cm X 9 Mtr , Microporus Hypoallergenic Non Woven Tape 5 Cm X 9 Mtr , Microporus Hypoallergenic Non Woven Tape 7.5 Cm X 9 Mtr , Microporus Hypoallergenic Non Woven Tape 10 Cm X 9 Mtr , Gamjee Roll Non Sterile 10 Cm X 2.7 M , Gamjee Roll Non Sterile 15 Cm X 2.7 M , Medicated Dressing (Band-Aid Strips) Regular 70 Mm X 19 Mm - Box(100Pcs) , Medicated Dressing (Band-Aid Strips) Wash Proof 70 Mm X 19 Mm - Box(100 Pcs) , Medicated Dressing (Band-Aid) Spot 22Mm - Box(200 Pcs) , Belladonna Plaster 17 Cm X 11 Cm , Capsicum Plaster 17 Cm X 11 Cm , Corn Cap 22 Mm X 70 Mm X 4S , Gauze Swab T-17 - 5 Cm X 5 Cm X 8 Ply , Gauze Swab T-17 - 7.5 Cm X 7.5 Cm X 8 Ply , Gauze Swab T-17 - 10 Cm X 10 Cm X 8 Ply , Paraffin Gauze Dresssing 10 Cm X 10 Cm X 1S , Paraffin Gauze Dresssing 10 Cm X 10 Cm X 10S , Paraffin Gauze Dresssing 10 Cm X 10 Cm X 20S Tin , Paraffin Gauze Dresssing 10 Cm X 30 Cm X 1S , Chlorhexidine Gauze Dresssing 10 Cm X 10 Cm X 1S , Chlorhexidine Gauze Dresssing 10 Cm X 10 Cm X 10S , Chlorhexidine Gauze Dresssing 10 Cm X 30 Cm X 1S , Combine Dressing 10 Cm X 10 Cm X 1S , Combine Dressing 10 Cm X 20 Cm X 1S , X-Ray Detectable Abdominal Pad 25 Cm X 25 Cm X 8 Ply , X-Ray Detectable Abdominal Pad 25 Cm X 40 Cm X 8 Ply , X-Ray Detectable Abdominal Pad 25 Cm X 25 Cm X 12 Ply , X-Ray Detectable Abdominal Pad 30 Cm X 30 Cm X 10 Ply , X-Ray Detectable Abdominal Pad 30 Cm X 30 Cm X 12 Ply , Plaster Of Paris Bandage 7.5 Cm X 2.7 Mtr , Plaster Of Paris Bandage 10 Cm X 2.7 Mtr , Plaster Of Paris Bandage 15 Cm X 2.7 Mtr , Kinesiology Tape , Elastic Adhesive Bandage 8 Cm X 1 Mtr , Elastic Adhesive Bandage 8 Cm X 2/3 Mtr , Elastic Adhesive Bandage 8 Cm X 4/6 Mtr - Tin , Elastic Adhesive Bandage 10 Cm X 1 Mtr , Elastic Adhesive Bandage 10 Cm X 2/3 Mtr , Elastic Adhesive Bandage 10 Cm X 4/6 Mtr-Tin , Rigid Athletic Tape 1 X 15 Yd , Rigid Athletic Tape 1.5 X 15 Yd , Rigid Athletic Tape 2 X 15 Yd , Premium Rigid Athletic Tape 1.5 X 15 Yd , Premium Rigid Athletic Tape 2 X 15 Yd , Rigid Strapping Tape 1 X 15 Yd - Brown , Rigid Strapping Tape 1 X 15 Yd - White , Rigid Strapping Tape 1.5 X 15 Yd - Brown , Rigid Strapping Tape 1.5 X 15 Yd - White , Rigid Strapping Tape 2 X 15 Yd , Economy Rigid Athletic Tape 1.5 X 15 Yd , Porous Rigid Athletic Tape 1.5 X 15 Yd , Zinc Oxide Rigid Athletic Tape 1 X 10.9 Yd , Zinc Oxide Rigid Athletic Tape 1.5 X 10.9 Yd , Zinc Oxide Rigid Athletic Tape 2 X 10.9 Yd , Rigid Cohesive Bandage 1.5 X 15 Yd , Elastic Strapping Tape 1.5 X 7.5 Yd , Lightweight Elastic Adhesive Bandage 1.5 X 7.5 Yd , Lightweight Elastic Adhesive Bandage 2 X 5 Yd , Lightweight Elastic Adhesive Bandage 2 X 7.5 Yd , Lightweight Elastic Adhesive Bandage 3 X 5 Yd , Lightweight Elastic Adhesive Bandage 3 X 7.5 Yd , Elastic Adhesive Sports Tape 2 X 7.5 Yd , Elastic Adhesive Sports Tape 3 X 7.5 Yd , High-Strength Elastic Adhesive Bandage 1 X 5 Yd , High-Strength Elastic Adhesive Bandage 2 X 5 Yd , High-Strength Elastic Adhesive Bandage 3 X 5 Yd , Elastic Adhesive Bandage 2 X 5 Yd , Elastic Adhesive Bandage 3 X 5 Yd , Elastic Adhesive Bandage 4 X 5 Yd , Cohesive Elastic Bandage 1 X 6Yd , Cohesive Elastic Bandage 2 X 6Yd , Cohesive Elastic Bandage 3 X 6Yd , Cohesive Elastic Bandage 4 X 6Yd , Cohesive Elastic Bandage 6 X 6Yd , Cohesive Compression Bandage , Cohesive Stretch Wound Compression Tape 2 X 5 Yd , Cohesive Compression Bandage 3 X 5 Yd , Plantar Fasciitis Support Tape | Reg - 7 Applications , Finger Protection Tape , Foam Underwrap Tape , Prewrap - Underwrap Paper , Adhesive Abrasion Protection Tape Roll 2 X 10 Yd , Adhesive Abrasion Protection Tape Roll 4 X 10 Yd , Adhesive Abrasion Protection Tape Roll 6 X 10 Yd , Dynamic Tape , Fixomull , Foam Padding With Adhesive , Silicon Gel Sheet , Moleskin Padding Roll - 24 X 4 5/8 , Latex-Free Moleskin - 1 X 5 Yd , Latex-Free Moleskin - 2 X 5 Yd , Silicone Scar Tape Roll - 1.6 X 60 , Medical Silicone Tape - 2Cm X 1.5Mtr , Mouthguard W/O Strap , Mouthguard With Strap , Ice Bag 9 , Cotton Roll Pack Small , Cotton Roll Pack Big , Cotton Bandage 4” , Cotton Bandage 6” , Band Aid Strips Box(100Pc) , Tape Adherant Spray , Tape Remover Spray , Skin On Skin Spenco 200Pc , Adhesive Felt Pad 5 Cm X 5 Cm (Pck Of 5) , Adhesive Felt Pad 10 Cm X 10 Cm (Pck Of 5) , Precut Adhesive Felt Pad 5 X 5 Cm With 2.5 Cm Diameter Hole (Pck Of 5) , Precut Adhesive Felt Pad 10 X 10 Cm With 4 Cm Diameter Hole (Pck Of 5) , Precut Adhesive Felt Pad 10 X 10 Cm With 5.5 Cm Diameter Hole (Pck Of 5) , Generic Scissiors – 6 Ss , Generic Scissiors – 8 Non Stick , Angled Taping Scissiors – Standard - Ss , Angled Taping Scissiors – Standard - Non Stick , Angled Taping Scissiors – Premium - Ss , Angled Taping Scissiors – Premium - Non Stick , Angled Bandage Scissors , Kinesiology Scissors , Volini Spray 60Ml , Volini Gel 30Gm , Drez Spray 40Gm , Neck & Back Pain Relief Patches Heat Wraps - 10 Count , Vicks Vaporub Chest Rub & Balm - 50Gm , Mistress Spray , Relispray Nitron Cool Spray , Deep Freeze Spray , Deep Freeze Gel , Deep Heat Spray , Deep Heat Gel , Sweatblock Antiperspirant Lotion For Hands & Feet – 50Ml , Sweat Block Antiperspirant Gel For Face – 50G , Magnesium Oil Spray , Fitogal Horse Balsam , Betadine Solution 100Ml , Betadine Oinment 20 Gm , Silverex Ionic Gel/ Soframycin - 20Gm , Sevlon Liquid 100Ml , Dettol Antiseptic Liquid - 250 Ml , Mycoderm Antiseptic Powder - 150 Gm , Instant Bleeding Stopper Powder , Steri-Strip - 6 Mm X 100 Mm, Pack Of 10 , Silicone Foam Wound Dressing 10X10cm – Sterile, Waterproof, Pack Of 5 , Spirit (Isopropyl Alcohol 99.9% Pure) - 300 Ml , Hand Sanitizer Gel - 55 Ml , Hand Sanitizer Liquid - 500 Ml , Alco Swab Alcohol Gauze Box - 100Pc , Hand Sanitizer Dispenser - 2 L , Hand Sanitizer Dispenser - 1 L , Germ Protection Wet Wipes Pack , Wet Wipes , Ultra Sound Gel - 250 Ml , Ultra Sound Gel - 5 Ltr. , Massage Cream Naqi 500Ml , Massage Cream Uk Sports , Olivia Massage Cream , Blue Nitrile Examination Gloves Box - 100Pcs , Latex Medical Examination Hand Gloves Box - 100 Pcs , Pre-Sterilized Surgical Skin Marker Set - 10Pcs , Disposable Mask Pack - 25 Pcs , Disposable Shoe Cover - 100 Pairs , Pocket Cpr Mask/Cpr Kit , Disposable Bedsheet Non-Woven Fabric (White, 35X72inch, 30 Gsm) - 100 Pcs , Tissue Paper Napkin , Toilet Tissue Roll , Reusable Non-Woven Kitchen Towels Roll , Tissue Paper Roll , Tissue Paper Napkins Pull Box , Face Tissue Box , Cloth Napkin - 45Cm X 45 Cm , Hand Towel , Body Towel , Microfiber Cleaning Cloth , Reusable Zip Lock Storage Bags - 45 Count (15 Each - S, M, L) , Eco-Friendly Garbage Bags - 1 Roll (15 Bags, 24 X 32) , Wheel Chair - Basic , Wheel Chair - Heavy Duty Steel , Wheel Chair - Premium , Powered Wheel Chair - Basic , Powered Wheel Chair - Premium , Walking Stick , Walking Stick - L Type , Walking Stick - Folding , Walking Stick - Quadripod , Walking Stick - Tripod , Elbow Crutch - Adjustable , Axillary Crutch (Pair) , Walker - Basic , Walker - Premium , Walker - Front Wheels , Hernia Belt , Stockinette 10Mtr - 5Cm , Stockinette 10Mtr - 7.5Cm , Stockinette 10Mtr - 10Cm , Stockinette 10Mtr - 12.5Cm , Stockinette 10Mtr - 15Cm , Compression Sleeve - Arm , Compression Sleeve - Calf And Shin , Compression Sleeve - Thigh , Air Mattress , Finger Cot Splint , Thumb Spika , Scortal Support , Silicone Heel Gel Sleeve Pair , Soft Gel Finger Tube (Length 6 X Diameter-0.59) , Heel & Lace Pads Box - 2000 Pcs , Silicone Foot Arch Support , Sitting Wedge , Analogue Upper Arm Blood Pressure Monitor , Oconnor Tweezer Dexterity Test By Oconnor , Distance Measuring Laser Tool – 150M , Distance Measuring Laser Tool – 100M , Distance Measuring Laser Tool – 50M , Kestrel Pocket Wind Meter , Babinski Reflex Hammer , Lactate Testing Kit , Lactate Test Strips - 25 , Moist Pack Set (4Pcs) , Reusa/Eu/Australiable Hot And Cold Ice Gel Pack With Adjustable Strap , Hydrocollator Unit , Cupping Set , Mini Pedal Exerciser With Resistance Adjustment & Digital Display , 40 Foldable Trampoline Rebounder , 45” Trampoline Rebounder With Adjustable Handle , 50 Trampoline Rebounder With Adjustable Handle , Jumping Trampoline With Enclosure Net - 16 Ft. , Exercise Gym Ball Base With Resistance Band Handle , Portable Hand Pump , Portable Foot Pump , Balance Pods , Sport Balance Trainer , Exercise Balance Pad , Hot And Cold Eyes Mask , Cool Eyes , Adjustable Aerobic Stepper , Mulligan Mobilization Belt , Peripheral Drop , Chiropractic Adjusting Tool - Standard , Chiropractic Adjusting Tool - Expert , Chiropractic Adjusting Tool - Pro Select , Vicks Inhaler , Candid Dusting Powder - 250 Gm , Candid Activ Talc - 100 Gm , Disposable Manual Shaving Razor - 10 Pcs Pack , Coagulant Spray , Battery 1.5V Aa , Battery 1.5V Aaa , Battery 9V , Torch Light , Emergency Rechargeable Led Lantern , Hair Dryer , Mosquito Bat , Hit Spray Flying Insect Killer , Room Spray , Velcro Straps Set (Small, Medium, Large) , Whistles With Lanyard , Compass For Directions , Silicone Ice Tray , Olive Oil – 1L , Olive Oil – 5L , Paraffin Wax (Slab) – 1 Kg , Paraffin Wax (Pellets) – 500Gm , Podiatry Kit , Oxygen Concentrator - 5Lpm , Portable Oxygen Can Pack - 6L With Mask, Tube & Elastic Strap , Yoga Mat 4Mm , Yoga Mat 6Mm , Yoga Mat 8Mm , Yoga Mat 10Mm , Gym Mat - 6 Mm - 36”X75” , Foam Roller (12) , Foam Roller (18) - Plain , Foam Roller (18) - Textured , Foam Roller (36) , Foam Roller Half Round (36) , Foot Roller Green Apac , Green Roller Massager , Portable Roller Massager , Yoga Belt / Strap - White , Yoga Block / Bricks Eva - Big 6 X 9 X 3 , Yoga Block / Bricks - Small 4 X 9 X 3 , Wooden Massager Stick - 10 Beads , Wooden Massager Stick - 20 Beads , Peanut Shaped Massage Ball , Wooden Body Massager With Accu Wheels , Wooden 6 Ball Pain Relife Roller , 4 Wheel Wooden Soft Roller , Acupressure Wooden Ball , Acupressure Wooden Roller - Big , Acupressure Wooden Roller - Small , Kansya Wand Wooden Massager Jimmy - Big Bronze , Kansya Wand Wooden Massager Jimmy - Small Bronze , Bolster , Acupressure Beak Roller - Wooden , Acupressure Beak Roller - Plastic , Acupressure Mat Block - Wooden , Acupressure Mat Block - Super With Copper , Acupuncture Needles With Tube 13Mm , Acupuncture Needles With Tube 25Mm , Acupuncture Needles With Tube 40Mm , Acupuncture Needles With Tube 50Mm , Acupuncture Needles With Tube 60Mm , Acupuncture Needles With Tube 75Mm , Acupuncture Needles With Tube 100Mm , Acupuncture Needles With Tube 125Mm , Foam Plyometric Box (20 X 24 X 30) , Foam Plyometric Box Set Of 4 (6, 12, 18, 24) , Wooden Plyometric Box S (12 X 14 X 16) , Wooden Plyometric Box M (16 X 20 X 24) , Wooden Plyometric Box L (20 X 24 X 30) , Wobble Board For Standing Anti-Fatigue Foam Pad , Wobble Wooden Balance Board - Circular , Rocker Wooden Balance Board - Rectangular - 180* , Rocker Wooden Balance Board - Rectangular - 360* , Balance Board Trainer Wooden - Skate , Interlocking Exercise Foam Mats -120Sqft (30Tile) , Rubber Tile 20 X 20 X 10Mm , Rubber Tile 20 X 20 X 20Mm , Exercise Mat - 25Mm X 75Cm X 180Cm , Gym Mat - 50Mm X 90Cm X 180Cm , Combat Mat - 55Mm X 2 Mtr X 1 Mtr , Crash Mat - 18 X 6’ X 4’ , Dumbbell Vinyl - 0.5 Kg , Dumbbell Vinyl - 1 Kg , Dumbbell Vinyl - 1.5 Kg , Dumbbell Vinyl - 2 Kg , Dumbbell Vinyl - 3 Kg , Dumbbell Vinyl - 4 Kg , Dumbbell Vinyl - 5 Kg , Dumbbell Vinyl - 7.5 Kg , Dumbbell Vinyl - 10 Kg , Medicine Ball - 1Kg , Medicine Ball - 2Kg , Medicine Ball - 3Kg , Medicine Ball - 4Kg , Medicine Ball - 5Kg , Medicine Ball - 6Kg , Medicine Ball - 7Kg , Medicine Ball - 8Kg , Medicine Ball - 9Kg , Medicine Ball - 10Kg , Weight Cuff - 0.5 Kg , Weight Cuff - 1 Kg , Weight Cuff - 1.5 Kg , Weight Cuff - 2 Kg , Weight Cuff - 3 Kg , Weight Cuff - 4 Kg , Weight Cuff - 5 Kg , Rack For 6 Dumbbell Vinyls , Rack For 6 Medicine Balls , Adjustable Kettlebell With 6 Plates (5 Lbs Each) , Kettlebell Rack - 49?X19?X40? - Capacity 350Kg , Kettlebell - 2 Kg , Kettlebell - 4 Kg , Kettlebell - 6 Kg , Kettlebell - 8 Kg , Kettlebell - 12 Kg , Kettlebell - 16 Kg , Kettlebell - 20 Kg , Kettlebell - 24 Kg , Kettlebell - 28 Kg , Kettlebell - 32 Kg , Kettlebell - 40 Kg , Index Knobber W/ Cone , Index Knobber W/ Cap , Index Knobber W/ Ball , Index Knobber Pressure Tool Set (Wood) , Index Knobber Ii , Knobble , Knobble Ii , Jacknobber , Jacknobber Ii , Backnobber , Backnobber Ii , Vibrassager , Palmassager , Orbitmassager , Intraoral Tmj Trigger Point Release Tool , Hip Wrap With Hot/Cold Therapy And Trigger Point Massage , Knee Joint Model With Flexible Ligaments , Hip Joint Model With Ligaments , Shoulder Joint Model With Ligaments , Foot Joint Model With Ligaments , Hand Joint Model With Ligaments , Human Joint Models Set Of 5 - (Knee, Hip, Shoulder, Foot, Hand) , Elbow Joint Model With Ligaments , Human Spine Model With Pelvis, Nerves & Stand – Flexible With Herniated Disc , Ice Box - 4.5L , Ice Box - 26L , Ice Box - 28L , Ice Box - 45L , Ice Box - 49L , Ice Box - 52L , Ice Box - 66L , Ice Box - 10L Bag , Ice Box - 47L With Wheels , Ice Box - 56L With Wheels , Ice Box - 61L With Wheels , Ice Box - 94L With Wheels , Compact Ppe Waist Pack , Athletic Trainer Waist Pack , Modular Storage Pack , Sideline Sling Response Bag , Large Modular Storage Pack , Medical Utility Bag , Emergency Response Medical Bag , Athletic Trainer Briefcase , Compact Medical Supply Bag , Medium Medical Supply Bag , Athletic Trainer Shoulder Bag , Premium Medical Supply Bag , Versatile Medical Response Bag , Customizable Large Medical Bag , Large Multi-Use Roller Bag , Medical Device Roller Bag , Large Medical Supply Bag , Extra-Large Medical Supply Bag , Mat - Foldable Ruler , Functional Hop Test And Jump Assessment Mat – 600Cm × 20Cm , Functional Movement & Balance Assessment Mat – Sebt, Ybt, Ckcue, Wblt, Squat & Lunge Testing Tool , Hand Evaluation - 3-Piece Set - Features Lite 200 Lb Hydraulic Hand Dynamometer & 50 Lb Hpg , Hand Evaluation - 7-Piece Set - Features Lite 200 Lb Hydraulic Hand Dynamometer & 30 Lb Mpg , Hand Evaluation - 3-Piece Set - Features Standard 200 Lb Hydraulic Hand Dynamometer & 50 Lb Hpg , Hand Evaluation - 3-Piece Set - Features Hires, Large Head, Hand Evaluation Set (Dyna, Pinch, Gonio) , Hand Evaluation - 7-Piece Set - Features Digital Lcd Er 300 Lb Hydraulic Hand Dynamometer & 60 Lb Mpg , Wrist Evaluation - 4-Piece Set - Features 500 Lb , Hand Evaluation - 3-Piece Set - Features Hd 200 Lb Hydraulic Hand Dynamometer & 50 Lb Hpg , Hand Evaluation - 7-Piece Set - Features Hd 200 Lb Hydraulic Hand Dynamometer & 30 Lb Mpg , Hand Evaluation - 8-Piece Set - Sensory Evaluators (Baseline/Touch-Test) , Hand Evaluation - 8-Piece Set - Features Lite 200 Lb Hydraulic Hand Dynamometer & 50 Lb Hpg , Hand Evaluation - 8-Piece Set - Features Hd 200 Lb Hydraulic Hand Dynamometer & 50 Lb Hpg , Hand Evaluation - 8-Piece Set - Features Standard 200 Lb Hydraulic Hand Dynamometer & 50 Lb Hpg , Hand Evaluation - 8-Piece Set - Sensory Evaluators , Pinch Gauge - Mechanical - Blue - 30 Lb Capacity , Pinch Gauge - Mechanical - Red - 60 Lb Capacity , Pinch Gauge - Mechanical - Gold - 2 Lb Capacity , Pinch Gauge - Mechanical - Silver - 10 Lb Capacity , Hand Dynamometer - Hd - 200 Lb Capacity , Pinch Gauge - Hydraulic - Hd - 50 Lb Capacity , Pinch Gauge - Hydraulic - Lite - 50 Lb Capacity , Pinch Gauge - Hydraulic - Hires Gauge - Er 100 Lb , Pinch Gauge - Hydraulic - Standard - 50 Lb Capacity , Pinch Gauge - Hydraulic - Digital Lcd Gauge - Er , Pinch Gauge - Hydraulic - 100 Lb Analog Output , Pinch Gauge - Hydraulic - Hires Gauge - 50 Lb , Hand Dynamometer - Standard - 200 Lb Capacity , Hand Dynamometer - Lite - 200 Lb Capacity , Hand Dynamometer - Hires Gauge - 200 Lb , Hand Dynamometer - Hires Gauge - Er 300 Lb , Hand Dynamometer - Digital Lcd Gauge - Er 300 Lb , Hand Dynamometer - 300 Lb Analog Output Signal, , Wrist Dynamometer - Analog 500 Lb Capacity, With Knob Grip & Mount Bracket , Wrist Dynamometer - Digital Lcd 500 Lb Capacity, With Knob Grip & Mount Bracket , Hand Dynamometer - Accessory - Case Only For Standard And Digital Gauge , Hand Dynamometer - Accessory - Case Only For , Wrist Dynamometer - Accessory - Knob Grip Handle , Wrist Dynamometer - Accessory - Shovel Handle , Wrist Dynamometer - Accessory - Lever Handle , Wrist Dynamometer - Accessory - Rod Handle , Wrist Dynamometer - Accessory - Mounting Bracket For Tabletop Or Wall , Wrist Dynamometer - 500 Lb Capacity Analog Output Signal, No Gauge , Hand Dynamometer - Standard 200 Lb Capacity - Reverse Gauge Exercise/Feedback Model , Pinch Gauge - Hydraulic - Standard - 50 Lb Capacity - Reverse Facing Gauge , Smedley Spring Dynamometer, Adult, 220 Lb. , Smedley Spring Dynamometer, Child, 110 Lb. , Smedley Digital Hand Dynamometer , Dynamometer - Pneumatic Squeeze Bulb - 30 Psi Capacity, No Reset , Dynamometer - Pneumatic Squeeze Bulb - 30 Psi Capacity, With Reset , Dynamometer - Pneumatic Squeeze Bulb - 15 Psi Capacity, No Reset , Dynamometer - Pneumatic Squeeze Bulb - 15 Psi Capacity, With Reset , Dynamometer - Pneumatic 3-Bulb Combo Kit - 30 Psi Capacity, With Reset , Manual Muscle Tester - Mechanical - Includes 3 Push, 2 Pull Attachments - 2.2 Lb Capacity , Manual Muscle Tester - Mechanical - Includes 3 Push, 2 Pull Attachments - 5 Lb Capacity , Manual Muscle Tester - Mechanical - Includes 3 Push, 2 Pull Attachments - 10 Lb Capacity , Manual Muscle Tester - Mechanical - Includes 3 Push, 2 Pull Attachments - 60 Lb Capacity , Manual Muscle Tester - Mechanical - Includes 3 Push, 2 Pull Attachments - 22 Lb Capacity , Manual Muscle Tester - Electronic - Includes 3 Push, 2 Pull Attachments - 50 Lb Capacity , Manual Muscle Tester - Electronic - Includes 3 Push, 2 Pull Attachments - 100 Lb Capacity , Manual Muscle Tester - Electronic - Includes 3 Push, 2 Pull Attachments - 250 Lb Capacity , Manual Muscle Tester - Electronic - Includes 3 Push, 2 Pull Attachments - 500 Lb Capacity , Gauge Tester With Push-Pull Dynamometer , Manual Muscle Tester - Accessory - Small Curved Push Pad , Manual Muscle Tester - Accessory - Straight Push Pad , Manual Muscle Tester - Accessory - Large Curved Push Pad , Manual Muscle Tester - Accessory - Small Flat Circular Push Tip , Manual Muscle Tester - Accessory - Small Pull Hook , Manual Muscle Tester - Accessory - Medium Pull Hook , Manual Muscle Tester - Accessory - Threaded Oval Spring Hook , Manual Muscle Tester - Accessory - Single Grip Handle , Manual Muscle Tester - Hydraulic - Includes 3 Push, 2 Pull Attachments - Digital Lcd Gauge - 500 Lb Capacity , Manual Muscle Tester - Hydraulic - Includes 3 Push, 2 Pull Attachments - Analog Gauge - 500 Lb Capacity , Manual Muscle Tester - Accessory - Dual Grip Handle (Also For Wrist , Manual Muscle Tester - Hydraulic - Includes 3 Push, 2 Pull Attachments - Analog Gauge - 50 Lb Capacity , Manual Muscle Tester - Hydraulic - Includes 3 Push, 2 Pull Attachments - Analog Gauge - 100 Lb Capacity , Manual Muscle Tester - Hydraulic - Includes 3 Push, 2 Pull Attachments - Analog Gauge - 250 Lb Capacity , Manual Muscle Tester - Hydraulic - Includes 3 Push, 2 Pull Attachments - Digital Lcd Gauge - 50 Lb Capacity , Manual Muscle Tester - Hydraulic - Includes 3 Push, 2 Pull Attachments - Digital Lcd Gauge - 100 Lb Capacity , Manual Muscle Tester - Hydraulic - Includes 3 Push, 2 Pull Attachments - Digital Lcd Gauge - 250 Lb Capacity , Back-Leg-Chest Dynamometer - Standard Platform - 660 Lb Capacity , Back-Leg-Chest Dynamometer - Standard Platform - 330 Lb Capacity , Back-Leg-Chest Dynamometer - Standard Platform - 165 Lb Capacity , Back-Leg-Chest Dynamometer - Oversize Platform - 660 Lb Capacity , Back-Leg-Chest & Manual Muscle Tester Accessory - Standard Lifting , Back-Leg-Chest & Manual Muscle Tester Accessory - Oversize Lifting , Cable Tensiometer - 660 Lb Capacity , Cable Tensiometer - 330 Lb Capacity , Cable Tensiometer - 165 Lb Capacity , Manual Muscle Tester - Accessory - Single Grip , Manual Muscle Tester - Accessory - Ankle Cuff , Manual Muscle Tester - Accessory - Thigh Cuff , Manual Muscle Tester - Accessory - Wrist Cuff , Manual Muscle Tester - Accessory - Shoulder Harness , Back-Leg-Chest Dynamometers Accessory - Lifting Chain, 1 Foot Length , Back-Leg-Chest & Manual Muscle Tester Accessory - Snap Oval For Lifting Platform , Back-Leg-Chest & Manual Muscle Tester Accessory - Threaded Oval For Manual Muscle Tester Connection , Manual Muscle Tester - Accessory - 7-Piece Pack With 3 Push And 4 Pull Accessories , Electronic Pinch Gauge , Pinch Gauge - Hydraulic - 5-Level Pinch Clinic Mode - 50 Lb Capacity , Pinch Gauge - Hydraulic - 5-Level Pinch Feedback Mode - 50 Lb Capacity , Wrist Inclinometer , Hydraulic Hand Dynamometer To Manual Muscle Tester Combo - Push Attachments Only , Hydraulic Hand Dynamometer To Manual Muscle Tester Combo - Dual Handle Only , Hydraulic Hand Dynamometer To Manual Muscle Tester Combo - Lite Hydraulic Hand Dynamometer With Push , Hydraulic Hand Dynamometer To Manual Muscle Tester Combo - Standard Hydraulic Hand Dynamometer With Push , Hydraulic Hand Dynamometer To Manual Muscle Tester Combo - Hd Hydraulic Hand Dynamometer With Push , Hydraulic Hand Dynamometer To Manual Muscle Tester Combo - Lite Hydraulic Hand Dynamometer With Push Attachments And Dual Handle , Hydraulic Hand Dynamometer To Manual Muscle Tester Combo - Standard Hydraulic Hand Dynamometer With Push Attachments And Dual Handle , Hydraulic Hand Dynamometer To Manual Muscle Tester Combo - Hd Hydraulic Hand Dynamometer With Push Attachments And Dual Handle , Wall Growth Chart , Plastic Goniometer - 360 Degree Head - 12 Inch , Plastic Goniometer - 360 Degree Head - 8 Inch , Plastic Goniometer - 360 Degree Head - 6 Inch , Plastic Goniometer - Pocket Style - 180 Degree , Plastic Goniometer - Rulongmeter Style - 360 Degree Head - 6 Inch Arms , Finger Goniometer - Metal - Standard - 6 Inch , Finger Goniometer - Metal - Deluxe - 6 Inch , Plastic Goniometer - Finger - Flexion To Hyper- , Finger Goniometer - Plastic - 1-Finger Design - 6 , Finger Goniometer - Metal - Small - 3.5 Inch , Finger Goniometer - Metal - 1-Finger Design - 6 Inch , Metal Goniometer - 180 Degree Range - 18 Inch , Plastic Absolute+Axis Goniometer - 360 Degree Head - 12 Inch Arms , Plastic Absolute+Axis - Attachment Only For 12 Inch , Metal Absolute+Axis Goniometer - Digital 180 Degree Range, 9 Inch Arms , Plastic Goniometer - 6-Piece Set , Hi-Res Measuring Set (1 Ea: 8, 12 360 Goniometer, 6 Pocket Goniometer, 60 Tape) , X-Ray Radiopaque Goniometer - 180 Degree Range - , X-Ray Radiopaque Goniometer - 180 Degree Range - , X-Ray Radiopaque Goniometer - 180 Degree Range - , Metal Goniometer - 180 Degree Range - 8 Inch Legs , Metal Goniometer - 180 Degree Range - 14 Inch , Metal Goniometer - 180 Degree Range - 6 Inch Legs - , Metal Goniometer - 6-Piece Set , Digital Plastic 360 Degree 10 Inch Goniometer , Metal Goniometer - 360 Degree Range - 14 Inch , Gravity Inclinometer , Bubble Inclinometer , Digital Inclinometer , Functional Finger Motion Gauge , Universal Inclinometer With Clip , Universal Inclinometer With Headband , Large Joint Protractor , Posture Evaluation - 2-Piece Set - Evaluator And , Posture Evaluator , Posture Grid , Posture Evaluation - 3-Piece Set - Protractor, , Sit N Reach Trunk Flexibility Box , Sit N Reach Trunk Flexibility Box - Deluxe , Body Level , Scoliosis Meter - Metal , Isom Measurement Chart , Adjustable Wall Goniometer , Scoliosis Meter - Plastic Economy , Medical Skinfold Caliper , Economy Plastic Skinfold Caliper , Skinfold Caliper - Accessory - Calibration Block Only , Economy Plastic Skinfold Caliper, Slim-Guide Style , Medical Skinfold Caliper - Deluxe Dual-Sided Model , Hand-Held Body Fat Monitor (Metric Only) , Hand-Held Body Fat Analyzer - Palm-Size - Baseline , Credit-Card Style Body Fat Analyzer , Acuangle Adjustable-Feet Inclinometer , Scale - Body Fat Scale , Measurement Tape With Gulick Attachment, 60 Inch , Measurement Tape With Gulick Attachment, 72 Inch , Measurement Tape With Gulick Attachment, 120 , Measurement Tape With Hands-Free Attachment, , Measurement Tape, 60 Inch , Measurement Tape, 72 Inch , Measurement Tape, 120 Inch , Finger Circumference Gauge, 6 Inch Maximum , Finger Circumference Gauge, 15 Cm Maximum , Finger Circumference Gauge, 6 Inch / 15 Cm , Multi-Filament Pen, 4 Monofilament Sizes , Monofilament - Retracting Filament - 1 Gram , Monofilament - Retracting Filament - 10 Gram , Monofilament - Retracting Filament - 100 Gram , Monofilament - Retracting Filament - 3-Piece Set (1,10 And 100 Gram) , Folding Monofilament, 1 Gram , Folding Monofilament, 10 Gram , Folding Monofilament, 100 Gram , Folding Monofilament, 3-Piece Set (1, 10, 100) , Dolorimeter - 2 Pound Capacity , Dolorimeter - 5 Pound Capacity , Dolorimeter - 22 Pound Capacity , Dolorimeter - 60 Pound Capacity , Dolorimeter - 10 Pound Capacity , Cleanwheel Sterile Disposable Neurological , Cleanwheel Non-Sterile Disposable Neurological , Aesthesiometer - Plastic - 2-Point Discriminator , Aesthesiometer - Plastic - 2-Point Discriminator , Aesthesiometer - Stainless Steel - 2-Point , 2-Point Disk-Criminator, 2 Disk Set, Metal Tips , 2-Point Discrim-A-Gon, 2 Disk Set, Plastic Tips , Multi-Setting Two-Point Discriminator , Tactile Monofilament - Protective Case - 2 , Tactile Monofilament - Protective Case - 6 , Tactile Monofilament - Protective Case - 24 , Tactile Monofilament - 2-Piece Set - Normal - 2.83, , Tactile Monofilament - 5-Piece Set - Hand - 2.83, 3.61, 4.31, 4.56, 6.65 Gram , Tactile Monofilament - 6-Piece Set - Foot - 2.83, 3.61, 4.31, 4.56, 5.07, 6.65 Gram , Tactile Monofilament - 20-Piece Set - Complete , Tactile Monofilament - 2-Piece Set - Protective Sensation - 4.56, 5.07 Gram , Tactile Monofilament - Leap Program - Disposable - 5.07 - 10 Gram - Single Unit , Tactile Monofilament - Ada Program - Disposable - 5.07 - 10 Gram - Single Unit , Windmill Type Spirometer , Accessory - 100 Plastic Mouthpieces , Accessory - 500 Paper Mouthpieces , Accessory - 1000 Paper Mouthpieces , Accessory - 250 Paper Mouthpieces , Fold-Up Monofilament, Evaluator Hand Set With Case (Set Of 5: 2.83, 3.61, 4.31, 4.56, 6.65) , Fold-Up Monofilament, Evaluator Foot Set With Case (Set Of 6: 2.83, 3.61, 4.31, 4.56, 5.07, 6.65) , Fold-Up Monofilament, Evaluator Set With Case (Set Of 20: 1.65 Through 6.65) , Fold-Up Monofilament, Normal Limit Set , Fold-Up Monofilament, Protective Sensation (Set) , Fingertip Pulse Oximeter, Standard , Fingertip Pulse Oximeter, Deluxe , Fingertip Pulse Oximeter, Pediatric , Fingertip Pulse Oximeter, Taa Compliant , Lite Pedometer, Step Only, Includes Strap , Standard Pedometer, Step, Distance & Calorie , Deluxe Pedometer, Step, Distance, Calorie, Activity Time, Includes Strap , Bims Digital 5-Position Grip Dynamometer, Clinic , Bims Digital 5-Position Grip Dynamometer, Deluxe , Bims Digital 5-Position Pinch Dynamometer, Clinic , Bims Digital 5-Position Pinch Dynamometer, Deluxe , Bims Digital 5-Position Dynamometer, 3-Piece Hand Evaluation Set, Clinic Model , Bims Digital 5-Position Dynamometer, 3-Piece Hand Evaluation Set, Deluxe Model , Bims Digital 5-Position Dynamometer, 3-Piece Hand Evaluation Set, Functional Model , Hand Dynamometer - 300 Lb Dial Gauge And Analog , Pinch Gauge - Hydraulic - 50 Lb Dial Gauge And Analog Output Signal , Wrist Dynamometer - 500 Lb Capacity Dial Gauge & Analog Output Signal , 24-Hour Combination Stopwatch/Clock , Wristwatch Blood Pressure And Pulse Monitor , Electronic Blood Pressure Monitor , 9 Hole Pegboard , Volumetric Measuring Device - Hand Set, 3X5x9 Inch , Volumetric Measuring Device - Arm Set, 7X7x30 Inch , Volumetric Measuring Device - Foot Set, 5X13x9 Inch , Volumetric Measuring Device - Forearm Set, 6X6x24 , Volumetric Measuring Device - Partial Leg Set , Volumetric Measuring Device - Large Partial Leg Set, 8X13x16 Inch Cavity , Pinch Gauge - Hydraulic - 5-Level Pinch - Additional , Plastic Goniometer - Hires 360 Degree Head - 12 , Plastic Goniometer - Hires 360 Degree Head - 8 , Plastic Goniometer - Hires 360 Degree Head - 6 , Plastic Goniometer - Pocket Style - Hires 180 Degree Head - 6 Inch Arms , Plastic Goniometer - Rulongmeter Style - Hires 360 Degree Head - 6 Inch Arms , Plastic Goniometer - Finger - Hires Flexion To Hyper- , Plastic Absolute+Axis Goniometer - Hires 360 Degree Head - 12 Inch Arms , Plastic Goniometer - Hires 6-Piece Set , Xtender Hires 360 Isom Goniometer , Tactile Monofilament - Ada/Leap/Lops - Disposable W/Sleeve - 5.07 - 10 Gram - 1 Ea. , Monitor Exercise Feedback Device , Digital Timer , Whey Gold - 100% Whey Protein Isolate - 30G Protein Per Serving - 1Kg , Whey Gold - 100% Whey Protein Isolate - 30G Protein Per Serving - 2Kg , Whey Gold - 100% Whey Protein Isolate - 30G Protein Per Serving - 4Kg , Whey Protein - Ultra Premium Whey Blend - 25G Protein Per Serving & 5.5G Bcaa - 1Kg , Whey Protein - Ultra Premium Whey Blend - 25G Protein Per Serving & 5.5G Bcaa - 1.8Kg , Whey Protein - Ultra Premium Whey Blend - 25G Protein Per Serving & 5.5G Bcaa - 2Kg , Whey Protein - Ultra Premium Whey Blend - 25G Protein Per Serving & 5.5G Bcaa - 4Kg , Biozyme Iso Zero Low Carb - 27G Protein Per Serving - 1Kg , Biozyme Iso Zero Low Carb - 27G Protein Per Serving - 2Kg , Biozyme Iso Zero Low Carb - 27G Protein Per Serving - 4Kg , Biozyme Performance Whey- 25G Protein Per Sachet - Box Of (5 X 36Gm Sachet) , Biozyme Performance Whey - 25G Protein Per Serving - 1Kg , Biozyme Performance Whey - 25G Protein Per Serving - 2Kg , Biozyme Performance Whey - 25G Protein Per Serving - 4Kg , Biozyme Whey Protein - 25G Protein Per Serving - 1Kg , Biozyme Whey Protein - 25G Protein Per Serving - 2Kg , Biozyme Whey Protein - 25G Protein Per Serving - 4Kg , Biozyme Gold - 26G Protein Per Serving - 1Kg , Biozyme Gold - 26G Protein Per Serving - 2Kg , Biozyme Whey Pr - 30G Protein Per Serving - 1Kg , Biozyme Whey Pr - 30G Protein Per Serving - 2Kg , Fuel One - Lean Muscle Mass - 24G Protein Per Serving - No Maltodextrin - 1Kg , Fuel One - Lean Muscle Mass - 24G Protein Per Serving - No Maltodextrin - 2Kg , Raw Whey Protein 80% - 24G Protein Per Serving - 1Kg , Raw Whey Protein 80% - 24G Protein Per Serving - 2Kg , Raw Whey Protein 80% - 24G Protein Per Serving - 4Kg , Whey Performance - 24G Protein Per Serving - 13 Rich Vitamins - 1Kg , Whey Performance - 24G Protein Per Serving - 13 Rich Vitamins - 2Kg , Whey Performance - 24G Protein Per Serving - 13 Rich Vitamins - 4Kg , 100% Micellar Casein - 24G Protein Per Serving, 5.6G Bcaa - 1Kg , 100% Micellar Casein - 24G Protein Per Serving, 5.6G Bcaa - 2Kg , Whey Energy - 24G Protein Per Serving, No Added Sugar - 1Kg , Whey Energy - 24G Protein Per Serving, No Added Sugar - 2Kg , Biozyme Clear Whey Isolate - 20G Protein Per Serving - 540Gm , 20G Protein Bar - Pack Of 6 , 10G Protein Bar - Pack Of 6 , High Protein Gold Gainer - 27G Protein Per Serving, Mass Gainer, No Added Sugar - 1Kg , High Protein Gold Gainer - 27G Protein Per Serving, Mass Gainer, No Added Sugar - 3Kg , High Protein Gold Gainer - 27G Protein Per Serving, Mass Gainer, No Added Sugar - 5Kg , Weight Gainer - 12G Protein Per Serving, Combination Of Proteins, Carbohydrates And Fats - 1Kg , Weight Gainer - 12G Protein Per Serving, Combination Of Proteins, Carbohydrates And Fats - 2Kg , Weight Gainer - 12G Protein Per Serving, Combination Of Proteins, Carbohydrates And Fats - 3Kg , Weight Gainer - 12G Protein Per Serving, Combination Of Proteins, Carbohydrates And Fats - 5Kg , Carb Blend - 72G Carbs Per Serving, Balanced Glycogen - 3Kg , Bulk Gainer - 17.6G Protein Per Serving, 27 Vitamins And Minerals - 1Kg , Bulk Gainer - 17.6G Protein Per Serving, 27 Vitamins And Minerals - 3Kg , Bulk Gainer - 17.6G Protein Per Serving, 27 Vitamins And Minerals - 5Kg , Mass Gainer Xxl - 18G Protein Per Serving - 1Kg , Mass Gainer Xxl - 18G Protein Per Serving - 2Kg , Mass Gainer Xxl - 18G Protein Per Serving - 3Kg , Mass Gainer Xxl - 18G Protein Per Serving - 5Kg , Super Gainer Black - 12G Protein Per Serving, Digestion & Testo Blend - 1Kg , Super Gainer Black - 12G Protein Per Serving, Digestion & Testo Blend - 2Kg , Super Gainer Black - 12G Protein Per Serving, Digestion & Testo Blend - 3Kg , Super Gainer Black - 12G Protein Per Serving, Digestion & Testo Blend - 5Kg , Fuel One Max Gainer - 1Kg , Fuel One Max Gainer - 3Kg , Biozyme 5 In 1 Multivitamin - 90 Tabs , Testo Surge Black - 60 Tabs , Testo Surge Black - 90 Tabs , Mb-Vite Daily Multivitamin - 30 Tabs , Mb-Vite Daily Multivitamin - 60 Tabs , Mb-Vite Daily Multivitamin - 90 Tabs , Mb-Vite Daily Multivitamin - 120 Tabs , Fish Oil (1000 Mg) - 30 Capsules , Fish Oil (1000 Mg) - 60 Capsules , Fish Oil (1000 Mg) - 90 Capsules , Fish Oil (1000 Mg) - 120 Capsules , Fish Oil (1000 Mg) - 180 Capsules , Fish Oil Gold - 3X Strength - 60 Capsules , Strongher Women Multivitamin - 60 Tabs , Zma - 60 Tabs , L-Arginine - 90 Capsules , Wrathx Pump - 300Gm , Pre Workout Wrathx - 340Gm , Pre Workout Wrathx - 510Gm , Pre Workout 200 Extreme - 3000Mg L-Citrulline, 2000Mg Beta Alanine - 100Gm , Pre Workout 200 Extreme - 3000Mg L-Citrulline, 2000Mg Beta Alanine - 200Gm , Pre Workout Crea Xtreme - 200Gm , Pre-Workout Ripped - 250Gm , Pre Workout Alter Ego - 250Gm , Pre -Workout 200 - 100Gm , Bcaa 2:1:1 Ratio 5000Mg Power - Box Of (7Gm X 28 Sachets) , Bcaa Pro - 240Gm , Bcaa Pro - 250Gm , Bcaa Pro - 450Gm , Bcaa Pro - 500Gm , Bcaa Gold - 450Gm , Creatine Monohydrate - 100Gm , Creatine Monohydrate - 250Gm , Creatine Monohydrate - 280Gm , Creatine Monohydrate - 400Gm , Creapro - 100Gm , Creapro - 250Gm , Citrulline Malate - 100Gm , Eaa 8000 - 340Gm , Eaa 6000 - 250Gm , One Sports Hydra 8 - Rehydration Formula - 5 Electrolytes, Bcaas, Vitamin C And Zinc - 15Tabs , One Sports Hydra 8 - Rehydration Formula - 5 Electrolytes, Bcaas, Vitamin C And Zinc - 20Tabs , One Sports Hydra 8 - Rehydration Formula - 5 Electrolytes, Bcaas, Vitamin C And Zinc - 60Tabs , Sports Energy Gel - 500 Mg Electrolytes, 75 Mg Caffeine, 85 Kcal - 35Gm - Pack Of 5 , Energy Bars - 200Kcal - Pack Of 6 X 40G , L-Glutamine - 5G Of Glutamine Per Serving - 250Gm , Hydr8 Isotonic - Instant Energy Boost, Rapid Rehydration, Faster Recovery - 1Kg , Liquid L-Carnitine - Boosts Cellular Energy, Fat Metabolism & Weight Management - 300Ml , Liquid L-Carnitine - Boosts Cellular Energy, Fat Metabolism & Weight Management - 450Ml , Liquid Carnitine Pro - Triple The Strength, Enhanced Fat Metabolism - 450Ml , Mb Fat Burner Pro - Convert Fat Into Energy, Suppresses Appetite, Boosts Natural Weight Loss - 60 Tablet , Cla 1000 Fat Burner (Conjugated Linoleic Acid Soft Gelatin Capsules) - 90 Capsules , L-Carnitine L-Tartrate - 30 Capsules , L-Carnitine L-Tartrate - 60 Capsules , L-Carnitine L-Tartrate - 90 Capsules , Biozyme Shred - 90 Capsules , Bottle Pro, 2 L , Cyclone Shaker, 700 Ml , Stainless Steel Shaker, 750 Ml , Insulated Steel Bottle, 1 L , Mens Multivitamin – 30 Tablets , Mens Multivitamin – 60 Tablets , Womens Multivitamin – 30 Tablets , Womens Multivitamin – 60 Tablets , Essential Multivitamin – 30 Tablets , Odourless Wild Fish Oil 1500Mg – 40 Capsules , Odourless Wild Fish Oil 1500Mg – 60 Capsules , Odourless Wild Fish Oil 1500Mg – 90 Capsules , Odourless Wild Fish Oil 1500Mg – 200 Capsules , Odourless 4X Strength Wild Fish Oil 1800Mg – 60 Capsules , Odourless Wild Fish Oil 1000Mg – 150 Soft Capsules , Odourless Wild Fish Oil 1000Mg – 200 Soft Capsules , Clinical Strength Deep Sea Krill Oil – 30 Capsules , Collagen+ Hyaluronic Acid – 30 Tablets , Collagen Glow Powder – 90G Oral Powder , Vegan Collagen Builder – 30 Tablets , Biotin+ – 30 Tablets , Biotin+ – 60 Tablets , Glutathione+ – 30 Soft Capsules , High Strength Cranberry – 30 Capsules , Iron – 30 Tablets , Mens Endurance Boost – 30 Tablets , Magnesium – 60 Tablets , High Strength Magnesium Glycinate & Citrate – 90G Oral Powder , Magnesium, Calcium + D3 – 60 Tablets , Vitamin D – 90 Tablets , Vegan Calcium + Vitamin D – 60 Tablets , Calcium + Vitamin D – 90 Tablets , Heart Health – 30 Soft Capsules , Co Enzyme Q10 – 50 Capsules , Joint Repair – 60 Tablets , Glucosamine Sulfate+ – 60 Tablets , Liver Detox – 30 Tablets , Liver Detox – 60 Tablets , High Strength Milk Thistle – 30 Tablets , Lutein & Zeaxanthin Eye Health+ – 30 Tablets , Metabolism+ – 60 Tablets , Immunity Booster+ – 30 Tablets , Probiotic+ Prebiotic Gummies – 30 Gummies , Plant Protein – 500G , Ultra Omega-3 (Epa 525Mg & Dha 400Mg) – 30 Tablets , Ultra Omega-3 (Epa 525Mg & Dha 400Mg) – 90 Tablets , Advanced Multivitamin For Sports, Unflavoured – 30 Tablets , Advanced Multivitamin For Sports, Unflavoured – 90 Tablets , Shilajit With 80+ Trace Minerals – 10G , Shilajit With 80+ Trace Minerals – 20G , T Boost, Unflavoured – 60 Tablets , T Boost, Unflavoured – 120 Tablets , Multivit Men, Unflavoured – 30 Tablets , Multivit Men, Unflavoured – 90 Tablets , Advanced Multivitamin For Women, Unflavoured – 30 Tablets , Advanced Multivitamin For Women, Unflavoured – 90 Tablets , Liver Detox With Silybin Milk Thistle Extract – 75 Tablets , Glutathione + Nutroxsun, Unflavoured – 30 Tablets , Joint Ease With 1500Mg Of Glucosamine & 1200Mg Of Chondroitin – 90 Tablets , Vegan Omega 3 6 9 – 90 Softgels , Advance Calcium Vitamin D3 & K2mk7, Unflavoured – 90 Tablets , Ashwagandha With 600 Mg Of Ksm-66 – 60 Capsule , Aceclofenac (100Mg) + Paracetamol (325Mg) – Strip Of 15 Tablets , Aceclofenac (100Mg) + Paracetamol (325Mg) + Serratiopeptidase (10Mg) – Strip Of 10 Tablets , Amoxycillin – Strip Of 10 Tablets , Azithromycin – Strip Of 5 Tablets , Olopatadine 0.2% – Eye Drop 5Ml , Ivermectin (6Mg) + Albendazole (400Mg) – Strip Of 1 Tablets , Cefexime – Strip Of 10 Tablets , Cetirizine (5Mg) + Paracetamol (325Mg) + Phenylephrine (10Mg) – Strip Of 10 Tablets , Chloramphenicol – Strip Of 10 Capsule , Trypsin Chymotrypsin (100000Au) – Strip Of 20 Tablet , Chlorzoxazone (500Mg) + Diclofenac (50Mg) + Paracetamol (325Mg) – Strip Of 10 Tablet , Cholecalciferol-60000Iu – Strip Of 4 Capsule , Ondansetron (4Mg) – Strip Of 10 Tablet , Elemental Iron (100 Mg) + Folic Acid (1.5 Mg) – Strip Of 10 Tablet , Camphor-25Mg + Chlorothymol-5Mg + Eucalyptol-125Mg + Menthol-55Mg + Terpineol-120Mg – Strip Of 15 Capsule , Levocetirizine (5Mg) + Montelukast (10Mg) – Strip Of 15 Tablets , Levocetirizine (5Mg) – Strip Of 10 Tablet , Levocetirizine (10Mg) – Strip Of 10 Tablet , Ammonium Chloride-138Mg + Diphenhydramine-14.08Mg + Sodium Citrate-57.03Mg – Syrup 100Ml , Alpha Lipoic Acid-100Mg + Folic Acid-1.5Mg + Mecobalamin-1500Mcg + Pyridoxine Hydrochloride-3Mg – Strip Of 10 Capsule , Metronidazole – Strip Of 10 Tablet , Cholecalciferol-1000Iu + Magnesium-250Mg – Strip Of 10 Tablet , Moxifloxacin-0.5%W/V – Eye Drop 5Ml , Loteprednol Etabonate (0.5% W/V) + Moxifloxacin (0.5% W/V) – Eye Drop 5Ml , Calcium Pantothenate (50 Mg) + Cyanocobalamin (15 Mcg) + Nicotinamide (45 Mg) + Riboflavine (10 Mg) + Thiamine Mononitrate (10 Mg) + Vitamin B6 / Pyridoxine (3 Mg) – Strip Of 30 Tablets , Ofloxacin (200Mg) + Ornidazole (500Mg) – Strip Of 10 Tablet , Pantoprazole – Strip Of 15 Tablets , Paracetamol – Strip Of 10 Tablet , Piroxicam (20Mg) – Strip Of 10 Tablet , Carboxymethylcellulose-0.5%W/V – Eye Drop 10Ml , Diclofenac (50Mg) – Strip Of 10 Tablet , Diclofenac (50Mg) + Paracetamol (325Mg) – Strip Of 10 Tablet , Dicyclomine (20Mg) + Paracetamol (325Mg) – Strip Of 10 Tablet , Vitamin D3 / Cholecalciferol(60000.0 Iu) – Strip Of 12 Capsule Total In Figures 0.0 0.0 Inr Zero Only 4.0 Construction Of Chamber For 100Mm Sluice Plates Item5 10.0 Nos Quoted Rate In Figures Select % 0.0 0.0 Zero Only Quoted Rate In Words Inr Zero Only
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Madhya Pradesh View Result →
16.
Drinking Water Supply and Sanitation #10653248 Price Bid
Supply Of Laptop & Other Equipment Under National Hydrology Project ( Nhp ) .- 1 Photocopier Multi Function Machine- Automatic Document Feeder / Radf, Warm Up Time: 18Sec. Or Less, Paper Capacity: 500*2 Trays ( Minimum 50 Sheet Bypass Tray ) , Counter: 5 Digit Digital, Power: Ac 230+10% Volts 50Hz, Tonner Capacity: 20000 Or Higher, Minimum Numbers Of Copies Taken Per Month: 100000, Copy Paper Size: A3 To A6, Continuous Copy Speed: A4 Paper 1-999, Zoom: 25% To 400% In 1% Step, Copying Resolution: Upto 600X600 Dpi, Copy Mode: Text, Text / Photo, Photo / Color Document, Output: Duplex, Duplex Printing: Automatic / Manual, Printing Speed Upto 32 Ppm A4 Size & 17 Ppm A3 Size Paper, Run Time, First Copy Out Time: Approx 3-5 Sec., Original Size: Maximum A3, Print Resolution: Upto 1200*1200 Dpi, Print Cartridge: Black, Print Technology: Monochrome Laser, Ram: 2Gb, Hard Disk: 320 Gb, Wifi Yes, Drum Life: 600000 Or Higher. 2 Multi Function Machine :Color, Multifunctional System -Minimum Numbers Of Copies Taken Per Month: 100000, Print / Scan / Copy / Optional Fax, Pages Per Minute : Color And Black-Printing Speed Upto 25 Ppm A4 Size & 12 Ppm A3 Size Paper, Warm Up Time : 18 Sec. Or Less, First Page Out:Copy 6.4 Sec. Black & 8.5 Sec. Color, Print: 7.0 Sec. Black & 9.2 Sec. Color, Paper Size: A3 To A6, Display: 10.1 Color Touch Screen Control Panel, Resolution: 1200X1200 Dpi, Ram: 4Gb, Hard Disk Drive: 320 Hdd Standard, Ssd: 8 Gb, Duplex : Standard Stack Less, Continuous Copy Speed: A4 Paper 1-999, Duplex Support Statement, Standard Output Tray: 500 Sheet, Electrical Requirement: 120V., 60 Hz, 12A: 220-240V, 50 Hz, 7.2A, Dimension: 23.7W X 26.2 Dx31.1 H, Compatibility:Window 7 Or Higher, Zoom : 25%-400% In 1% Step Increments, Resolution: 600X600dpi. 3 Laptop- 10Th Gen Intel Core-I7 Processor 15.6” Fhd Laptop ( I7-10750H / 8Gb / Itb, Ssd / Window 10 Pro / Nvidia Gtx 1650 Ti 4 Gb / Shadow Black / 2.36 Kg ) , 15-Ek0018txwith Quick Heal Total Security Antivirus With Three Year Pack * Laptop Of Hewlett, Packard / Dell / Lenovo / Brands Only 4 Firewall Hardware 250 User. Performance : Firewall Throughput ( Mbps ) - Should Be 12, 000 Or Above, Antivirus Throughput ( Mbps ) - Should Be 1, 540 Or Above, Ipsec Vpn Throughput ( Mbps ) - Should Be 7, 100 Or Above, Ssl Vpn Throughput ( Mbps ) - Should Be 700 Or Above, Utm Throughput ( Mbps ) - Should Be 1, 530 Or Above, Interfaces- Should Be Minimum 12 Gbe Or Above, I / O Interfaces - Should Be Minimum 2 Usb Ports Or Above, Concurrent Sessions - Should Be 90, 00, 000 Or Above, Console Port, Branch Office Vpn ( Ipsec / Ssl ) - Should Be Unrestricted, Mobile User Vpn ( Pptp / Ssl ) -Should Be Unrestricted.Product Updates: Supports Regular Product Updates For Bug Fixes, And Small Enhancements, Signature Updates For Antivirus, Ids / Ips, Web Security, Support For Online And Offline ( Manual ) . Backup / Restore: Configuration Backup / Restore, Scheduler For Configuration Backup, Factory Reset. Authentication Server Support: Multiple Authentication Servers Support ( Except Vpn ) , Local, Active Directory, Ldap, Guest Profile And Expiration Feature For Local User And Guest, Support Captive Portal Authentication. Routing: Static Routing, Policy Based Routing On User, Bgp Support, Ospf Support. Firewall: State Ful Firewall, Default Policy / Rules For 40+ Well Know Services With Provision To On / Off., Provision For Custom Rules, Ip / Icmp / Tcp-Related Attack Prevention, Dos &Ddos Attack Prevention, Multiple Zone Support For Security - Lan, Wan, Dmz, Vpn, Firewall, Nat Traversal ( H.323, Sip, Sccp, Mgcp ) - Protocol To Provide Voice And Video Services Over Ip Networks ( Nat 64, Dns 64, Static Nat, Advanced Nat, Dynamic Nat, Pat, And Dhcp V6 ) , Ipv6 Support, Flow Based And Dns Based Web Filtering Inspection Mode, Traffic Logging, Layer8 - User Identity Firewall, Unrestricted User Support. 5 5.1 Split Ac ( Inverter Model ) :- Supply, Installation, Testing And Commissioning Of Split Type Wall Mounted Air Conditioning Unit Of Following Capacity Including Indoor, Outdoor Unit Fitted With Inverter Based Rotary Compressor, Copper Condenser And First Charge Refrigerant R410a. The Condensing Unit Working Range Should Be Capable For Providing Cooling Between + / -5 Deg. C To 50 Deg. C & Heating Within 0 Deg. C To 15 Deg. C Including Connection Of Copper Pipe Of Required Size Upto 3 Mtr., Insulation, Cordless Remote Control, Auto Air Swing Louvers, Wall Stand For Outdoor Unit, Connection Copper Lead Wire, Condensed Water Outlet Pipe 2 Mtr. Complete Etc As Required. Outdoor / Indoor Units Should Be Of Same Make ( Brand ) . 1.5 Tr Star Rating 5 Star 1.8 / 2 Tr Star Rating 5 Star 6 5.2Split Ac ( Inverter Model ) :- Supply, Installation, Testing And Commissioning Of Split Type Wall Mounted Air Conditioning Unit Of Following Capacity Including Indoor, Outdoor Unit Fitted With Inverter Based Rotary Compressor, Copper Condenser And First Charge Refrigerant R410a. The Condensing Unit Working Range Should Be Capable For Providing Cooling Between + / -5 Deg. C To 50 Deg. C & Heating Within 0 Deg. C To 15 Deg. C Including Connection Of Copper Pipe Of Required Size Upto 3 Mtr., Insulation, Cordless Remote Control, Auto Air Swing Louvers, Wall Stand For Outdoor Unit, Connection Copper Lead Wire, Condensed Water Outlet Pipe 2 Mtr. Complete Etc As Required. Outdoor / Indoor Units Should Be Of Same Make ( Brand ) . 1.5 Tr Star Rating 5 Star 1.5Tr Star Rating 5 Star 7 Supply, Installation, Testing And Commissioning Of Ups With Isolation Transformer & Battery For Backup, Minimum Load Power Factor 0.8, Power Factor 0.99, Having Ovcd ( Over Voltage Cut-Off Device ) , Having Cvcf ( Constant Voltage Constant Frequency, Bypass Parameters Configurable, 2 Stage Charging ( Constant Current / Float Charge ) , Having Temperature Compensated Charger, Fan Speed Control, Digital Signal Processor Controller, Total Harmonic Distortion ( Current ) - Thdi ( <10%@50% R Load, Input 1 Phase Voltage 230V, Voltage Range 110-300V, Output Voltage ( 220Ac / 230Ac / 240Ac ± 1% ) , Total Harmonic Distortion Voltage ( Thdv- <3% Linear Load, <5% Nonlinear Load, 90 % Ac / Ac Efficiency, Over Load Capacity ( 105-110%: 3Min, 111-130%: 30Sec ) , Operating Temperature With Full Load 0-40°C, Communication Features ( Rs232, Usb Com Port, Intelligent Slot ( Optional ) . Ups Installation With All Required Material Arrangements As Required As Per Is Specification For 5 Kva ( 1 Phase Input And 1 Phase Output ) 60 Minute Backup, Min. 8000 Vah For E-Tendering And Edp Cell 8 Revolving Chair Heavy Duty, Arm Material: Pu Foam Bonded Chrome Coated, Seat Material Pu Foam Covered With Pure Leather ( Branded ) ( For Edp Cell ) . Material Of Back Cover And Fabric Of Seat: Pure Leather. 9 Printer Multifunction Auto Duplex Laser Printing Speed Upto 20 Ppm, Upto 5000 Pages Per Month, Copy Speed Up To 14 Ppm For Director Hydrometeorology / Data Centre Bhopal For Rtdas / Scada Monitoring Hall & Deputy Director, H / M Dn. No. 3, Rewa.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Madhya Pradesh View Result →
17.
Banking and Finance #10607564 Price Bid
E-Tender For Procurement Of Equipments For Siep -1 Pre- Vocational Unit 2 Children Wall Bar -n(•tThe Size should be : 85*52*168cmn•tMust be Use full for children to do standing and sitting training with the help of wall bars and muscle strength training as well as trunks traction and extension training.) 3 Children PT Stool(adjustable) -n(•tMust be use full for Used for children PT training.n•tIt must have Wheelsn•tIt should have Blue Leather Sitting) 4 Finger Correcting Board -n(•tUsed to correct fingers flection contracture and adduction malformation.n•tIt should have 4 holes) 5 Finger Correcting Board(with universal wheel) -n(•tUsed to correct fingers flection contracture and adduction malformation.n•tIt should have 3 holesn•tIt Should have 3 or 4 Wheels) 6 Hydraulic children step trainer -n(•tSize Must be: 70*56*97cmn•tWeight not more than: 29kgn•tUse full for lower limbs range of motion and muscle power training.) 7 Training Quoit -n(•tIt must be Use full for hand-eye coordination and perceptionn•tIt must be Use full Cognition training.) 8 Word cognitive puzzle –n(•tWeight not more than : 3.3Kgn•tMaterial must be: wooden) 9 Cognition Toys – n(•tSize should be: 30*30*30cmn•tWeight not more than: 8.7kgn•tShape must contain following:n-tCube 5pcsn-tCylinder 5pcsn-tTriangular 5pcsn-tCuboid 5pcsn•tIt must be use full for perception function training.) 10 Intelligence develop assembly – n(Size must be: 32.2*28.7*23.5cm) 11 PHYSIO-OCCUPATIONAL THERAPY UNIT 12 Treadmill- 2HP Noiseless AC motor 13 Short wave diathermy- 500W with valve 14 Bolsters of different sizes 15 Puzzle - Body parts with two facial expressions with box, Animal, Birds, fruits, transports, Different shapes 16 Shoulder CPM 17 Lower extremity CPM 18 CP chair 19 Static cycle 20 Bed cycle 21 weighing scale 22 texture fruit tree 23 Ball pool (48X 48) 24 perdue peg board 25 exercise mats - 6X3 26 exercise frame - rope mess, pip ladder and rock climbing board 27 Trampoline (48 Inch) 28 Quadriceps Table with detachable backrest 29 Stethoscope 30 blood pressure appratus 31 Goniometer – 180 & 360 degree 32 Electronic stopwatch 33 Digital weighting machine 34 Treatment trolley 35 Stainless steel stools 36 Tables 37 Chairs 38 Waiting chairs 39 Cupboards 40 Computer 41 Printer & scanner 42 Muscle stimulator Combo- with Current -Galvanic, Interrupted Galvanic, Faradic, Surged Faradic and TENS 43 Micro control 4 channel tens 44 Weight cuff- 1/4 kg, 1/2 Kg, 1 Kg, 1.5 kg -n(•tStrengthens weak muscles through load resisting exercises of both upper and lower limbs. n•tLead shots filled cuff is double sewn and had long wrap around straps to hold weight cuff securely in Place. n•tA full set consists of 4 color coded cuffs i.e. Capacity: 250 gm, 500 gm, 1 kg, 1.50 kg) 45 Thera band- different colors and ranges – n(•tTheraBand Rubber Latex Less Bands should be supplied with 5 feet length, 4-inch width of different colour (Yellow, Red, Green, Blue, Black) - Set of 5n•tIt should be Latex Less, No Scent, No Powdern•tColour-coded Progressive Resistance system should allow users to recognize improvement as it happens – when the patient grows stronger they can move up to the next color, for strength training and physical therapy programs. Colour-coded levels should be increasing in difficulty from Yellow to Black) 46 Thera putty with different colors & ranges – n(The system should have following parameters:n•tColours options : Tan, Yellow, Red, Green, Blue, Greyn•tWeight must be: 100grams eachnHigh Resistance Level)n 47 Portable shoulder exerciser with pronation supination arrangement 48 Grip exerciser 49 Hand Gym Kit Board –n(Laminated exercise boards with storage drawer, have several holes to fix Pegs and springs. The unit permits active flexion and extension exercises of the finger and grip.nSpecification:nHand Gymkit Board consists, One finger Disc, One Roller, Three Spring loaded Knobes, 3 pegs to support finger and 3 Sets of Springs of different tensions) 50 Wrist roll -n(The unit should have following parameters:n•tOne piece SS roll with three different diameters i.e. 30mm, 40mm and 50mm to be fitted on a laminated board n•tBoard size: 25cm x 80cm long with adjustable friction control mechanismn•tControllable from zero to maximum for flexion and extension exercises of wrist and forearm) 51 Rope pulley handle set –n(Shoulder Pulley Unit with rope adjustment system (Wall Mounting)n•tShoulder Pulley unit should provide exercises of the Elbow and shoulder. n•tTubular steel constructed unit should come with Pulleys, Nylon Rope, Handles and Wall fixing frame.n•tPulleys: Two, Nylon pulley n•tHandles: Two, spring steel wire handle with plastic grip.n Rope/Cord: Interwoven Nylon cord of suitable length.) 52 Upper extremity work station -n(should have facility of peg board, pinch tree, pipe assemble unit PVC, 25 holes peg board, multi shape peg board, hand tool test frame, finger dexterity board, door latch board, dressing board set, shoulder deduction ladder, bilateral shoulder ladder, hand exercise board Velcro, hand gym board, trolley with lock) 53 Vestibulator with facility of Platform swing, flexion disc, frog swing, Lycra swing , Bolster swing rectangular 54 Vestibular board - 3.6 X 2.6 X 7 – n(Vestibular Board should be of large size for rocking the body on board stimulates balance control with Vestibular Responses. nThe top should be of thickly upholstered and covered with rexine and washable fabric cover) 55 Scooter board – n(•tBoard with 4 Wheels (90cm Long x 30cm wide): It should help the child to learn body control, shifting weight, changing directions and maintain balance. Wooden Scooter Board with foam padded top should be used in a sitting, kneeling or prone position for developing strength of the upper and lower extremities.n•tIt should have ply-wood base, supported on 25mm x 25mm angular iron frame.n•tIt should have high density Foam padded top is 25mm thick & to be covered with nylon fabric in two Colours.n•tIt should be fitted with (4) four, 50mm dia castors.n•tBoard Size should be: 90cm long x 30cm wide) 56 Wedges of different sizes – n(•tWedges with set of four size: A: 15x60x70cm; B: 20x60x70cm; C: 25x60x70cm; D: 30x60x70cm) 57 Post box with 25 plates -n(•tSorting, Matching & Posting Box unit should measure an individual basic level of function in the area of colour identification and Eye-hand co-ordination.n•tConstruction of the box should be Laminated Wooden with five multicolour plastic plates fixed at the top with five Slots to Post matching colour plates there in.n•tIt should have 25 well-polished plastics plates in 5 different colors to sort, match and post.n•tBox should come with five compartments to be fitted with sliding door to store plates and also works as posting box.n•tIt should be Natural polished finish with laminated tops & door.) 58 Door latch board –n (The frame set provides learning opportunity and progressive development of dexterity. nWith six laminated doors, opening in different directions. nEach door opens into a shelf where a reward or toy can be kept. nCommon hardware of different designs, generally used in the home is used to familiarize Patient. Size of laminated unit is 26x18x5 deep.)nnn 59 Floor seater – n(•tFloor sitter should be useful for the child who cannot sit up on his own, and who needs his shoulders and upper trunk supported.n•tThese Floor Sitters must offer support in seating a child at floor level. This must allow the child to be independent, with hands free for play, while maintaining optimal erect trunk alignment.n•tConstruction: It should have Wooden Corner Seat, with broad base that help to prevent tipping.n•tSeat & Back should have Sitter with foam padded Seat, Sides and Back support.n•tAccessories should include abductor block, hip positioning belt & removable tray should be integral part of the floor sitter.nSeater should be finished in natural wood polish. Seat & Back to be covered with multi-colour Rexene) 60 Stand in table with Standing Metal Frame – n(Basic standing frame, with comfortably supports weight- bearing parts of the body. nIt Helps to prevent atrophy of leg muscles, improves range of motion, helps improve circulation, lessens muscle spasms and contractions n Three straps should be provided for heel, ankle and pelvic support) 61 Tunnel – n(•tCrawling tunnel Non-folding, Aluminum sheet with windows on sides and inner area padded with foam should be suitable hospitals with multiple patients.n•tTunnel Set of three parts with windows on sides are padded with soft Eva foam inside. n•tIt should be made in three parts of 90cm long each, all the three tunnels should be fixed together to make a single tunnel of 2.75 meter length.n•tInside Diameter should be 50cm dia.) 62 Treatment Plinth– 63 Wooden blocks of different heights- set of 6– 64 Peanut ball– n(•tIt can help you achieve muscle and tension release for all parts of the body.n•tPeanut shape design, convenient to use.n•tSuitable for yoga, Pilates, etc., help you has better fitness effect.n•tMade of durable PVC material for long term using.n•tFeatures: Peanut Shape, Inflatable, Explosion-proof, Durable, Fitness Tooln•tSize: 45cm x 95cm/17.72 x 37.40 (Approx.) 65 Staircase– n(•tStep arrangement: FOUR 15cm steps on one side, leading to platform size 75cm x 75cm. First step moves into the second to make it a bus step of 30cm height. 7.5cm steps on the other side. Steps are 75cm wide & 23cm deep (approx.).n•tFitted with 2 sets of handrails at different height to accommodate Adults & children. n•tSteps and Platform are made of commercial board of 12 mm thickness & covered with non-slip matting. n•tSides & Supporting frame of Steps are made of commercial board of 18mm thickness with hardwood reinforcement. n•tHand Rails & supporting bars are made of solid hardwood. Stairs finished natural) 66 Parallel bars with platform-n(•tParallel Bars should have adjustable Height & Width with PVC. n•tOuter uprights of thick steel tubing0 of 50mm dia. with Powder coating finish. n•tPlatform: Tubular steel reinforced platform with incline on both ends & is covered with non-slip matting. n•tLength: about 10feet n•tAdjustments: Should be easily done by means of setting Pins at the required holes & should be stabilized by tightening the screws. n•tFinish: Working Parts are with powder coated / chrome plated finish & wooden parts with Natural polish finish.n•tCovered with non-slip matting.n•tPostural Training Mirror: Mirror should be of size 175cm x 53cm (approx.) and should be protected by hardwood polished frame with back covered by ply board. n•tStand: Mirror should be fitted on tubular stand with powder coated finish) 67 Suspension framenSuspension Frame (with Accessories) without Bedn(•tSuspension Frame set for complete Suspension with Slings & Ropes. n•tTop Mesh should facilitate suspension at any desired point in relation to the patient and as required in each individual case. n•tConstruction: Tubular steel frame with 6mm thick Rod-mesh at Top and on Upper Sides. n•tLegs should be fitted With Rubber/PVC Shoes.n•tSizes: Overall sizes 210cm long x 110cm (approx.) wide at the base, 50cm (approx.) wide at the top & 190cm (approx.) high.) 68 Stability Disc–n(It should have balance Cushion - an Inflatable cushion that must come with 2 different surfaces that introduce an element of stability to a workout, must be ideal for both balance and core training. The balance cushion must allow users to exercise and working to stay balance; with constant micro movements that will strengthen the core muscles and improve postures. It should have the benefits of using Balance Cushion. Strengthen core muscles and improve postures required. Diameter- 33 cm required. Colors required: - Lime Green(Spiky Surface), Blueberry (Smooth Surface)) 69 Vibrator (with 6 attachments) – n(•tThe unit should be able to vibrate against the body and stimulate the nerves for a relaxing feeling.n•tIt should give horizontal circular motion which effectively relieves muscular fatigue and pain.n•tIt should have following two speeds:n•tHigh with rpm 3500n•tLow with rpm 1500n•tIt should have cooling system for continuous use so that massage can be done for long time.n•tIt should have durable body for professional use.n•tIt should be heavy duty and the weight should be above 2.5 kg.nIt should have two handles for applying pressure on the chest/muscle group.) 70 Ramp and curb– n(CURBS AND RAMP (without handrails) Hardwood constructed training set consists of ONE ramp and THREE nested curbs stored below the ramp. The ramp graduates from 20mm to 200mm and is 84 X 44. The curbs are 40x 40x 6, 36x 36x 4 and 32x 32x 2 respectively. Natural wood finish with anti-slip safety mats on ramp and curbs without handrails) 71 Balls for ball pool– n(It should have brightly colored balls encourage movement plus give child visual & tactile feed-back and support. * Size of ball should be of 7cm or 8cm dia with different colors) 72 Ankle exerciser-n(Painted aluminum boot with strap to hold the foot is mounted ona laminated base with Stainless steel sheet bracket having two springs for ankle (Dorsi and Plantar flexion) exercises. nResistance can be increased further by tightening springs nut. nDegree of flexion can be measured and recorded) 73 Walker with 4 castors - non folding-n(Walking Aid Folding & Adjustable HeightnLight weight, painted aluminum tubular construction, folds easily and quickly. Height of frame is adjustable from 75 c.m. to 90 c.m. by slipping locking pins in proper notch. Fitted with soft PVC hand grips and shoes) 74 Circle balance disc-n(•tThe board should have encourages Balance and Neuromuscular Re-education, Rhythm, Coordination and Vestibular responses. Children can use it in kneeling or standing position.n•tTop Diameter should be 51cm round, cushioned top covered with rexine.n•tBase must be fitted with semi-circular base, 60mm height.n Hand-Holds must be of Two, Side holds to be provided for stability) 75 Board for lower extremity - standing exercise 76 Foot placement ladder– n(•tIt should be useful in early walking with balance training. n•tShould be of wooden floor ladder with adjustable dividers, n•tShould offer various walking patterns. n•tSteps should be of equal size and alternately placed for right-left progression.n•tBeams & Dividers should be made of Teak-wood with size 96 long x 27 wide.n•tBeams should be finished in natural wood. n Adjustable 16 Divider bars should be finished in different enamel colours) 77 Graded spring set– n(•tSuspension Springs should be made out of best steel wire, with chrome plated finish; the rope is fitted in the spring to avoid overstretching.n•tTension of the springs must be: A. 5 kg-7kg., B.8kg-10kg., C. 12Kg-15kg. D. 18kg-20kg., E. 22kg-25kg.n•tSet should consist of ONE spring each (A+B+C+D+E) with S hooks.n•tIt should be Suitable for Extension, Flexion and Suspension activities.n It should be Full Set of 5 springs) 78 Long Handle thick grip spoons-n(•tIt should have stainless Steel long handled spoons, with smooth spoon tips.n•tThe spoons must help child/baby to master fine motor skills.n•tThese spoons must be easy to clean and maintain.n It should have set of 05 pieces) 79 Tactile balls for grip-n(•tIt should have Bumpy sensation when these are squeeze by hands. Knobby surfaces and bright colours should promote sensory and tactile exploration and it must help develop fine motor skillsn•tIt should have soft and squeezable material easy for small hands to grab and promote hand-eye coordinationn•tIt should have soft, knobby surface to provide massage stimulation for little ones. n•tIt should be supplied with Set which includes (06) toys in assorted colours and shapes (Round, Square, Cone, Pyramid & Rectangle etc.).n•tIt should be BPA, Latex and Phthalate freen•tIt should be helpful to build and define childs gross motor skillsn It must be Capture childrens interests and Hearts) 80 Lotca battery test-n(•tIt should have the plan to provide the appropriate therapy. n•tThe DLOTCA (Dynamic Lowenstein Occupational Therapy Cognitive Assessment) battery must design to offer this type of critical assessment. n•tThe DLOTCA battery must measure the cognitive abilities of those with neurological impairments or injuries.n•tIt should have a set of minimum 28 sub-tests analyses the cognitive areas pertaining to: Orientation, Awareness, Spatial Perception, Visual Perception, Vasomotor Construction, Praxis and Thinking Operations. n•tThe DLOCTA should be supplied with full kit with the following Components: Instruction manual authored by top leaders in the occupational therapy field Test booklets and score sheets Card and shape sets for various sub-tests.nPegs and peg-boards must have followings…n•tTen 1 x 1 natural wood blocks.n•tFour 1 x 1 blue wood blocks.n•tTwo 1 x 1 orange wood blocks.n•tThree 1 x 1 green wood blocks.n•tOne 1 x 1 yellow wood block.n•tButter-fly puzzle. Photo book.n•tSafety scissors.n•tPencil, paper and envelope.n•tCarrying bag.n•tThe kit is compact for easy transportation weighingn•t8.5 pounds and measuring 4.5 x 10.5 x 16.5 inches.) 81 Minnesota test-n(•tIt should measure manual dexterity of the Arm and Hand for manipulative work, utilizing a broad range of shoulder motion.n•tTest should involve Turning, Placing or moving the discs in a prescribed manner. Requires unilateral & bilateral movements.n•tTests should include 60 two colored plastic cylinders, plastic board, record forms and carrying case) 82 Exercise frame - rope mess, pip ladder and rock climbing board 83 Tilt Table– 84 Wobble Board– n(•tAnti-Slip Wooden Wobble Balance Board for Fitness & Training Rehabilitation Exercisen•tHigh Quality Material And Durable: Consisting of quality wood and tough plastic base, highn•tStrength, enduring for daily training.n•tStrength Stability: The balance board also enhancing the muscle strength of waist and n•tAbdomen, beautifying the hip muscle.n•tRotatable: The can support 360 degree horizontal rotating when placing it on flat ground.n•tKeep Balance: Stimulating posture conditioning, strengthening the stability of the vestibular.n•tOrgans and improving the bodys balance.n•tWidely Usage: The balance board is suitable to be used for hemiplegia stroke and other post-balance rehabilitation training.n•tWarranty not applicable for this product) 85 Cryo Therapy Unit–n(•tTherapeutic device should be capable to produce a real deep thermal shock effect.n•tThe thermal shock is a physiological stress should produce by sudden or rapid temperature variations in the local tissues.n•tThe system should not only allow performing cry therapy or hyperthermia separately but also and above all thermal shock therapy in a dynamic and controlled way.n•tHyperthermia, transdermal cryothermica and thermal shock can be modulated in depth and intensity.n•tShould be equipped with a treatment head based on the technology of Peltier cells capable of generating heat or subtracting heat in a range from +45°C to -18°C.n•tA special sensor should transmit the target temperature and the local body temperature should appears on the LCD screen in real-time to inform the operator how the therapy is acting on the patient.n•tAll the functions should be visualized on a large color LCD in addition to the usual and traditional keys and buttons,n•tShould be possible to adjust every parameter on the touch screen.n•tThe versatile Windows CE operating system should ensure possible upgrading.n•tShould have availability of a wide range of preset protocols with body maps. n•tThe screen should show the body parts to be treated and the unit should suggest the parameter values to set after selection of pathology is chosenn•tShould have free memories for entering customized protocols.n•tTemperature: from +45°C to -18°Cn•tShould have Colour touch screen displayn•tCompact unit with dimensions: 41 x 42 x 18 cm or smallern•tLight Weight: Not more than 9 kgn•tSafety class: class I type B, class IIa) 86 Electrical traction with 3 fold Bed-n(•tThe traction unit should consist of set of mechanisms for relieving pressure on the skeletal system.n•tIt should have a large LCD display panel showing all parameters.n•tIt should have at least 8 different modes (a) Intermittent (b) Static (c) Progressive/ intermittent (d) Progressive/ Static (e) Progressive/ Regressive (f) Cyclic /Intermittent (g) Cyclic / Static (h) Cyclic tn•tIt should consist of automatic calibration of traction force to maintain correct traction force.n•tIt should have high/low force range of 1-90 kg/0-89 kg.n•tIt should be possible to apply cervical as well as lumber traction with the machine.n•tIt should have adjustable hold and rest time range of 0 –99 sec.n•tIt should have selectable ramp steps of 2-8 steps with selectable pause time of 2-20 sec. for each step.n•tIt should have 5 different pulling speeds.n•tIt should have memories storage of at least 30 treatment patterns.n•tIt should have timer of 90 minutes.n•tIt should be supplied with Fixed Height Traction bed (Indigenous).n•tShould be supplied complete with Traction Unit, Cervical Harness ,Pelvic Harness, Spreader Bar, Patient Switch) 87 Treatment couch– n(HIGH-LOW TREATMENT TABLE (Electrical)nElectric, variable height, three section table is suitable for all treatments, including manipulation both ends elevate so that the back or legs can be raised without turning the patient. One ends also lower -20 deg. for some postural drainage & manipulation techniques and more comfortable sitting. The foam padded top is 195 cm long and 70 cm wide. Table height is adjustable from 50 cm to 90 cm. Frame-work in light blue oven baked finished) 88 Pain Relief System -n(•tCombination therapy unit with Heat, magnetic force and micro vibrations.n•tThe system should be modern with touch button operation.n•tThe system should consist of two channel unit with 2 hot packs for simultaneous use.n•tIt should have flexible heating pads emitting dry heat so that it can be used over clothes in normal conditions.n•tThe heating pads should have four steps temperature control from 35º to 60ºC.n•tMaximum temperature should not exceed 65 deg for patient protectionn•tIt should provide vibrations through flexible heating pads which help in the stimulation of blood flow on painful areas.n•tThe system should have three different types of micro vibrations as below :notRipple wave: - 70 vibrations per secondnotRandom wave: - 120 vibrations per secondnotBig wave: - 60 vibrations per secondn•tIt should also provide Magnetic force for improving the blood flow.n•tMicro vibration should be from alternating magnetic fieldn•tIt should have digital timer of 30 minutes duration.n•tIt should be supplied with an imported trolley and should work on 240 V/50 Hz power supply.n•tIt should UL, and ISO 13485 approved for patient safety) 89 Wheel Chair for Children– n(The system should have following parameters:n1.tPediatric Wheelchair, Aluminum Chair frame, fixed armrest, Detachable footrest, Drop-back handle, solid castor, pneumatic rear wheel, Anti-tippers.n2.tLoading weight should be minimum 100 kg) 90 Club foot Passive exerciser & Therapy System – n(•tThe CPM should be for treatment of the idiopathic club foot which should restores or maintains ankle and subtalar mobility in addition to preventing fibrosis and periarticular soft tissue changes.n•tThe CPM should be used in the post-operative phase of treatment.n•tThree dimensional movements should be possible:n•tPlantar flexion to Dorsi-flexionn•tAdduction-Varus to Abduction-Valgusn•tPlantar flexion-Adduction-Varus to Dorsi-flexion-Abduction-Valgusn•tDigital controls should allow easy programming.n•tAt rest or working the machine should maintain a light axial traction which off-loads the pressures which are applied to the ankle mortise to avoid any deformation of the tibio-talar joint line.n•tThe machine should be equipped with a system which reverses the movement when abnormal forces are detected.n•tIt should be European CE approved) 91 Children Medical Cycle-n(•tUpright Ergometer for physical abilities such as workload etc. n•tIt should be able to work continuous work load range from 7-1000 watt.n•tIt should work for minimum five minutes at a peak load of 1000 watt for short period.n•tThe work load should be adjustable @ 1 watt increment.n•tIt should have 7 inch touch screen programmable LCD display to show various parameters such as distance, torque, power, energy and time on its control panel.n•tIt should provide workload in hyperbolic, linear and fixed torque modes.n•tIt must have eddy current electro-magnetic braking system.n•tIt should have USB interface.n•tWorkload accuracy should be = 5%.n•tIt should display distance, torque and time on its control panel.n•tIt should have Rotatable height adjustable handlebar redundant, rotate at 360 degrees for comfortable at every seating height. n•tIts seat should be sleeplessly adjustable.n•tIt should comply with MDD 93/42/EEC, incl. IEC.) 92 Ultrasound- 1 and 3 MHz Frequency – n(Digital Dual Pre Programmable Ultrasound therapy unit with constant digital LCD display adjustable treatment should be supplied having following parameters: n?tNominal Frequency: 1MHz & 3MHzn?tPower Density : 0-3W/cm2 (Approx.)n?tMix Acoustic output: 15W (Approx.)n?tUltrasonic Output : Continuous- 2.5 W/cm, Pulse- 3.5 W/cmn?tPulse Frequency: 8hz, 16hz, 50hz, 10hzn?tPulsed Ratios: 1:1,1:4,1:7,1:10n?tTimer: 0-99 minutesn?tVoltage:220 V,50Hz±10%nAccessories to be supplied:n•t1 pair - Ultrasound Head (1Mhz) & Wiren•t1 pair - Ultrasound Head (3Mhz) & Wire n•t1 pc - Main Cord) 93 Computerized Interactive Dynamometer System:-n(Computerized interactive dynamometer system should have following specifications;n•tThe system should comprise of user-friendly and easy-to-control rehabilitation robot to allow rehabilitation Training with dynamically changing resistance, diagnostics, patient evaluation and interactive games.n•tThe system should be upgradable to make use of reactive electromyography (EMG) for neuro exercise. n•tSingle joints or functional and dynamic joint movement should be trained with isolating extensions. n•tThe robotic system should be suitable to provide Kinesitherapy for orthopedic, neurological and cardiac patients of Adult and Pediatric age groups. n•tShould have dedicated exercise program for patients with severe paresis and muscle atrophy. n•tSystem should offer active exercises on all extension for Patients with innerved muscles but severe atrophy n•tThe device should offer exercises for dexterity training with dynamically changing resistance: concentric with elastic resistance and weight simulation.nn•tShould have inbuilt games and dynamic resistance exercises and to improve movement coordination. n•tShould have the facility to upgrade with games working with reactive electromyography n•tShould have tablet mounted on a retractable arm with height adjustable lifting column and preloaded Software application for quick setup and operationn•tShould be mounted on wheels with brakes for easy transportation and immobilization of the robot n•tEach extension should support a maximal applied weight of at least 30 kg. n•tThe rotation axis height of head should be at least 720-1070 mm and rotation limits should be at least 270 degree clockwise and anticlockwise with accuracy at least ±2 deg and Maximum torque: at least 60 Nm with measurement accuracy at least ±0.2 Nm.n•tShould be supplied with changeable extension parts for training and exercise of different joints including Shoulder, Elbow, Hip, Knee, Functional upper limbn•tShould include following extensions easy to mount in any orientation by plug and rotate method and automatic detection by the software: n•tElbow pronation/supination dynamic extension - n•tSteering wheel dynamic extension - n•tUpper limb universal extensionn•t Lower limb universal extension n•tThe system have facility for bioelectric measurements for diagnostic and reactive electromyography with clip electrode for EMG Measurement n•tSystem should have adjustable Range of motion, rotational torque and speed to suit different patient conditions. n•tThe software should provide summary and detailed extension specific information about all performed exercises after every training. n•tSystem Should allow following exercises and diagnosis :na.tContinuous passive motion nb.tProgressive Continuous Passive Motionnc.tSpring (Elastic) exercises:nd.tIsotonic exercises (weight lifting)ne.tDynamic reversalnf.tPrioperception – Hidden/Visibleng.tReactive electromyography trigger and hold nh.tReactive electromyography trigger and release ni.tEMG Biofeedback nj.tDiagnostic EMG nk.tThe software should have three primary game categoriesni.tOrthopedic – acting like concentric exercisesnii.tReactive EMG – acting like reactive electromyography trigger and holdniii.tIsometric EMG – acting like EMG biofeedbacknl.tAt least two games should be provided: Space shooter and Bubble.ni.tSpace shooter a game where the patients control the movement of a spaceship. nii.tBubble- a logic game where patients control the position of a bubble gun launching different color bubbles to form patterns. nThe system should meet the requirements of ISO60601-1-2 for electromagnetic compatibility, including immunity. Should have Class I protection against electric current, Medical device class: class IIa Applied part types: B, BF. ) 94 Lymphatic drainage system 95 BONE GROWTH STIMULATOR 96 Two Channel Combination Therapy With Dual Frequency Ultrasound-n(The Main unit should have:-n•t2 channels electrotherapy unit with 4 electrodes & 1 channel dual frequency ultrasound (1 or 3MHz).n•tColoured touch-screen large LCD for all parameters setting.n•tSimultaneous monitoring of 2 electrotherapy & one ultrasound channel with independent and combined n•tThe unit should operate on100 - 240 VAC 50 Hz.n•tWeight of equipment should be approximately 3.5 Kg for ease of moving.n•tIt should have body diagram with associated clinical programsn•tIt should also have port for attaching vacuum unit. n•tSafety class according to IEC 60601-1: Class 1, Type BFn•tUnit should be European CE approved.nElectrotherapy specifications:n•tDigital Timer: 1-60 minutesn•tIt should also have provision of I/T curve measurement n•tIt should also have setting range for AQ mode whenever vacuum unit is attached.n•tIt should have approximately 28 preset and 120 free program memories n•tVector Sweep 0°, 15°, 30° or 45°nIt should have following setting range:n-tParameter setting range for 2-Pole Interferential moden•tOutput mode: Constant, Sweepn-tParameter setting range for EMS moden•tOutput mode: Surge Independent, Surge Co-Cont., Surge Alternaten-tParameter setting range for Russian moden•tOutput mode: Surge Independent, Surge Co-Cont., Surge Alternaten•tCarrier frequency: 2.5 kHz n•tDuty: 10 to 100% (10% steps)n-tParameter setting range for Hi-Voltage moden•tOutput mode: Constant, Sweep, Burst, Surge Independent, Surge Co-Cont.,n•tSurge Alternaten•tPolarity: positive, negative, alternaten-tParameter setting range for TENS moden•tOutput mode: Constant, Sweep, Burst, Surge Independent, Surge Co-Cont., Surge Alternaten•tWaveform setting: Symmetrical waveform, asymmetrical waveformn•tPolarity: positive, negative, alternaten-tParameter setting range for Micro current moden•tPolarity: positive, negative, alternaten-tParameter setting range for Galvanic moden•tOutput mode: Continuous, Interruptedn•tPolarity: positive, negativen-tParameter setting range for Faradic moden•tPolarity: Positive, negativen•tFrequency: 20 to 250 Hz (10-Hz steps)n-tParameter setting range for Diadynamic moden•tOutput mode: DF, MF, CP, CP-ISO, LP, RSn•tPolarity: positive, negativen•tFrequency: 50 Hz or 100 HznUltrasound specifications:n•tBeam Non-uniformity Ratio (BNR) which prevents hot spots & tissue damage should be less than 5.0 and must be mentioned on the technical literature.n•tEffective Radiating Area (ERA) for large probe should be max. 5 cm2 & for small probe should be max. 1.0 cm2n•tFrequency: 1 & 3 MHz from same headn•tMode: Continuous & pulsed; duty cycle 5-50%n•tMax. Intensity: 3w/cm2in pulsed mode & 2 w/cm2 in continuous mode.n•tDigital Timer: 1-30 minutesn•tMemory capacity of: 18 preset & 10 free Programsn•tUS Probe should be IPX7 protected.nCombination Therapy:n•tIt should work in combination of Ultra sound and electrotherapy with dedicated single electrode of channel 2 as return electrode for electrotherapy and active as US probe.nIt should be supplied with following accessories:nUltrasound head large and small with probe holder, Electrode Cable – 2 pcs., Rubber Electrode, 60x50mm, 2pcs/pack – 2 Pack , Electrode Sponge A, 80x65mm, 2pcs/pack – 2 Pack, Strap (L), 80x1200mm – 2 pcs., Strap (S), 80x600mm – 2 pcs, Ultrasound gel (250 ml), Power Supply Cord (220-240V, Type F) – 1 pc., MCR (Micro current) Probe (2pcs/set to be used), HV/DC ProbenVacuum Unitn•tVacuum unit for enhancing the operability of electrotherapy units especially in abdominal & back regions. n•tThe unit should consist of 2 channel vacuum system for 4 vacuum electrodes.n•tIt should have blow out vacuum system which eliminates the need of water reservoir & reducing maintenance.n•tThe unit should have 2 vacuum modes: Continuous mode & int ermittent mode for patient comfort & skin massage.n•tThe unit should have vacuum strength up to 100 mm Hgn•tThe unit should operate on 100 - 240 VAC with 50 Hz frequency power supplyn•tMain unit should be supplied with:- 4 rubber electrode, 4 electrode sponge, 2 electrode cable, 4 straps (2 large and 2 small), 4 Vacuum electrode, 4 Electrode sponges for Vacuum electrode, Power supply cord.) 97 AUDIOLOGY & SPEECH THERAPY UNIT 98 Single Portable Unit -Pure tone Audiometer with facilities of free field audiometry & speech audiometry with-nFrequency range for AC- 125Hz to 8000HznFrequency range for BC- 250Hz to 6000HznDynamic range (1000Hz)- -10dB HL to 120 dB HLnShould be European CE/ANSI/ISI approved 99 Non-sedated diagnostic BERA with 2 channel and VEMP, ABR & SSR facilities and computer accessibility through USB portal 100 Video Oto-scope with computer accessibility 101 Acoustic booth 15’x12’x 7’ with inner partition, double door, magnetic seal, silenced ventilation 102 Visi-pitch with all accessories 103 Bio feedback system for stammering therapy with all accessories 104 Speech therapy materials (Local purchase) 105 Mattress 6’ x 6’ 106 Group Hearing aid with loop induction system 107 Mattress 6’ x 6’ 108 PSYCHOLOGY UNIT 109 Binet Kamat Intelligence Test (BKT) 110 Intelligence Scale for Indian Children 111 Bhatia Battery of Performance Intelligence Test 112 Diagnostic Test of Learning Disability (DTLD) 113 Diagnostic Test of Reading Disorder (DTRD) 114 Behavioural Checklist for Screening the Learning Disabled (BCSLD) 115 Swarup-Mehta Test of Thinking Strategies (TTS) 116 Thematic Apperception Test (TAT) 117 Non-Verbal Group Intelligence Test (NVGIT) 118 Rorschach Ink Blot Test 119 (DAP:IQ)Draw-A-person Intellectual Ability Test for Children Adolescents and Adults 120 Conduct Disorder Scale (CDS) 121 Revised Hamilton Rating Scale for Depression (RHRSD) 122 Indian Adaptation of the Multidimensional 123 Aptitude Battery - MAB – II 124 Child Sexual Behaviour Inventory (CSBI) 125 Teachers Job Satisfaction Scale 126 ADHD Symptoms Rating Scale (ADHD-SRS) 127 CHILD & ADOLESCENT SYMPTOM INVENTORY-4R (CASI-4R) 128 Multiscore Depression Inventory for Children (MDI-C) 129 Stop Watch [Timer] Racer Electronics [SWE] 130 Gifted and Talented Evaluation Scales 131 Test of Memory and Learning - Second Ed. (TOMAL-2) 132 Early Childhood Inventory-4 (ECI-4) 133 Slosson Full-Range Intelligence Test (S-FRIT) 134 Bender Visual-Motor Gestalt Test - Second Edition (BGT - II) 135 Stroop Color and Word Test (Children) 136 Personality Inventory For Children 2nd Ed. 137 Seguin Form Board Test with Manual & Answer Sheets. 138 Childhood Autism Rating Scale - Second Edition (CARS 2) 139 Children’s Color Trails Test (CCTT) 140 Intelligence Test for Adult 141 State-Trait Anger Expression Inventory-2™(STAXI-2) 142 Multi-dimensional Anxiety Questionnaire (MAQ) 143 Substance Abuse Subtle Screening Inventory (SASSI-3) 144 Suicidal Ideation Questionnaire (SIQ) 145 Relaxation Chair 146 ISAA & INCLEAN TOOLS for ASD 147 BLOOD DISORDER DISABILITY UNIT 148 Thalassemia Rapid test 149 Blood Gas Analyzer 150 Methylene Blue Chemical – 151 Urine Analyzer– 152 VISUAL UNIT 153 Hand held slit lamp 154 Direct Ophthalmoscope 2.8 v 155 Trial set power cotted/Stereo Acuity Test material 156 Trial frame for both adult and paediatric 157 Distance vision testing drum remote control motorised movement 158 VS-V Universal Vision Screener (for school going children also) 159 Tele Binocular Equipment 160 LED Vision Chart 161 Snellen Chart/Eye Testing Drum 162 Automatic Matrix Auto Refractometer R-20 for eye Examination 163 Near Vision Drum 164 Acuity Digital Vision Tester 165 Keratometer&Keratoscope tools 166 Brallier (Braille Type Writer) 167 Orbit Reader (Braille Embossed Reader) 168 Pen Scanner 169 Magnifiers for low vision (NIEPVD) 170 MAGIC software for low vision 171 Electronic Mobility Cane/White Cane 172 TEACHING LEARNING MATERIAL-n(N.B.-All TLM should be made of Nontoxic, Hygienic material ensuring safety of children. Toys should not have any sharp edges to prevent any possible injury to children.) 173 Rattle toys-(Age Group 0 to 3 Years) 174 Fruit Tray-(Age Group 0 to 3 Years) 175 Parts of body-(Age Group 0 to 3 Years) 176 Building Towers-(Age Group 0 to 3 Years) 177 Different Balls-(Age Group 0 to 3 Years) 178 Zig saw Puzzle-(Age Group 0 to 3 Years) 179 Dolls-(Age Group 0 to 3 Years) 180 Wooden Blocks-(Age Group 0 to 3 Years) 181 Drum-(Age Group 0 to 3 Years) 182 English Alphabets & Numbers- (Age Group 3 To 6 Yrs.) 183 Flash Card of Alphabets & Numbers- (Age Group 3 To 6 Yrs.) 184 Eye hand coordination (Beads)- (Age Group 3 To 6 Yrs.) 185 Abacus– (Age Group 3 To 6 Yrs.) 186 Shape, Size, Colour, Concept &. puzzle box – (Age Group 3 To 6 Yrs.) 187 Zig saw Puzzle– (Age Group 3 To 6 Yrs.) 188 Colour book with crayon holder– (Age Group 3 To 6 Yrs.) 189 Easel and Board– (Age Group 3 To 6 Yrs.) 190 Magic Slate– (Age Group 3 To 6 Yrs.) 191 Blowing toys– (Age Group 3 To 6 Yrs.) 192 Picture and Ward Cards - (Age Group 7 To 11 Yrs.) 193 Assembly Kit- (Age Group 7 To 11 Yrs.) 194 Number Cards- (Age Group 7 To 11 Yrs.) 195 Zig Shaw Puzzle - (Age Group 7 To 11 Yrs.) 196 Telling Time Kit - (Age Group 7 To 11 Yrs.) 197 Count and Match - (Age Group 7 To 11 Yrs.) 198 Puzzle body parts - (Age Group 7 To 11 Yrs.) 199 Coloring Books with Crayons– (Age Group 7 To 11 Yrs.) 200 Beads– (Age Group 7 To 11 Yrs.) 201 Magic Slate– (Age Group 7 To 11 Yrs.) 202 Duplicate Currency– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 203 General Knowledge Flash Cards– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 204 Mobile Phone– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 205 Calculator– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 206 Digital Watch– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 207 Number Cubes– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 208 Multiplication Tactile Board– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 209 Worksheet, Pen & Duster, Story Books– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 210 Coloring Books with Crayons– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 211 Kitchen Set– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 212 SPORTS MATERIALS 213 Recreational Gaming Play Station 214 Eye Convalescence System –with Bed 215 EMG Biofeedback With Pelvic Floor Rehabilitation For Urinary Incontinence
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
18.
Science and Technology #10601472 Price Bid
Tender For Calibration Of Equipments And Devices - 2 Bata Belt Flexing Machine ( 231 ) - Counter Speed Nroller Speed Ndiameter Nroller Diameter Nroller Width 3 Upper Leather Water Proofness Tester ( 06 ) - Distance Between V Shaped Clamps Nunflexed Position Nflexed Position Nangle Between The Clamps In Fixed Position Ninternal Tip Radius Nrate Of Flexing N 4 Sartorius Electronic Balance ( 08 ) - Weight Measurement 5 Permeability Absorption Apparatus ( 09 ) - Internal Diameter Of Clamping Ring Nwater Bath Temperature Ninternal Height 6 Air Oven ( 10 ) - Temperature 7 Bottom Leather Grain Crack Tester ( 12 ) - Diameter Of Cylindrical Metal Mandrels, Mm 8 Lace To Eyelet Abrasion Tester ( 15 ) - Moveable Clamp Distance Nmoveable Clamp Speed Nmoveable Clamp To Stationary Clamp Distance Nforce Nspacer Angle N 9 Elastic Fatigue Flexing Machine ( 233 ) - Speed Nlength N 10 Touch & Elastic Fastener Cycling Machine ( 17 ) - Diameter Of Driven Drum Width Nslot Length Ndiameter Of Idling Drum Width Nslot Length Nrate Of Rotation Of Drum Ntime For Reverse Nweights N 11 Touch & Close Pressing Machine ( 18 ) - Roller Diameter Nweights 12 Slide Fastener Tester ( 19 ) - Distance Between Two Clamps ( D ) Nlateral Movement Of Clamps Nmass Of The Weights - Lateral Nmass Of The Weights - Longitudinal Nstroke Nspeed 13 Water Penetration Tester For Bottom Leather Sole ( 22 ) - Angle Of Test Specimen Nangle Of Flat Platform Nwidth Of Fixed Clamp Nclamping Edge Positioned To Central Line Nclamping Edge Positioned To Central Line Npivoting Distance N 14 Shoe Flexing Machine ( 24 ) - Speed Of Machine 15 Slider Fastener Closer Tester ( 26 ) - Tensile Force Measurement Nmoving Clamp Speed 16 Electrical Resistance Tester ( 30 ) - Voltage 17 Lastometer ( 237 ) - Load Nextension Nplunger Speed Nplunger Diameter 18 Heat Resistance Tester ( 37 ) - Tensile Force Measurement Nmoving Clamp Speed Ntensile Force Measurement 19 Sole Adhesion Tester ( 38 ) - Arc Length 20 Break Pipiness Tester ( 42 ) - Mandrel Radius Nrectangular Hole Dimensions Nlength Nwidth 21 Sltc Slit Tear Test Apparatus ( 44 ) - Top Attachment Jaw Nwidth Nthickness Ndepth Nangle Nbottom Attachment Jaw Nwidth Nthickness Ndepth Nangle N 22 Satra Whole Topline Bollands ( 45 ) - Diameter Of Cylindrical Bollard 1 Ndepth Of Cylindrical Bollard 1 Ndiameter Of Cylindrical Bollard 2 Ndepth Of Cylindrical Bollard 2 23 Compression Gauge ( 46 ) - Plunger Diameter N1. Main Body N2. End Face Nminimum Clearance Between The Plate And Clearance N 24 Satra Conical Finger ( 47 ) - Length Of Plunger Ndiameter Of Plunger Nat The Top Nat The Bottom N 25 Needle Holding Jig ( 50 ) - Plate With Space Plate Nwidth Nthickness Nplate With Needles Nwidth Nthickness Nspacing Plate Nwidth Nthickness Ndiameter Of Needle Hole Nall The 17 Holes Ndistance Between The Line Of Holes & The End Of Plate Ndistance Bet. The Center Of First And The Last Hole Nset At 3 Mm Nset At 6 Mm Nplate With Space Plate Nwidth Nthickness N 26 Nail And Test Piece Holing Jig ( 56 ) - Diameter Of Solid Metal Cylinder Nrigid Plate-Top Nrigid Plate-Bottom Ncollar Diameter Nnail Diameter Nhardness N 27 Ross Flexing In Low Temp ( 62 ) - Angle Nflexing Rate 28 Compression Set ( 66 ) - Diameter Of Solid Metal Cylinder Nrigid Plate-Top Nrigid Plate-Bottom Ncollar Diameter Nnail Diameter Nhardness Ndiameter Of Solid Metal Cylinder Nrigid Plate-Top Nrigid Plate-Bottom Ncollar Diameter Nnail Diameter Nhardness 29 Drum Abrasion ( 230 ) - Roller Diameter Nrpm Ninclination 30 Surface Water Absorption ( 71 ) - Internal Diameter Of Pot Nheight Nwidth Of Annular Flange N 31 Fiber Board Flexing Machine ( 74 & 74A ) - Jaw Taper Angle Nangle Of Flex On Each Side Ntip Radius Nrate Of Flex Nforce On Test Specimen N 32 Rub Fastness Tester ( 75 ) - Speed Nforce N 33 Bally Flexing Machine ( 77 ) - Flexing Rate Nflexing Angle Ntip Radius 34 Bally Penetrometer ( 229 ) - Speed Ncylinder Diameter Nmovement Nmax. Separation 35 Water Vapor Permeability Apparatus ( 79 ) - Internal Diameter Of Bottle Ninternal Height Of Bottle Ndistance Of Axial Centre Of Bottle Nspeed Nfan Speed Nfan Dimension 36 Martindale Abrasion Tester ( 224 ) - Mass Nlength 37 Water Vapor Permeability Testing ( 84 ) - Internal Diameter Of Bottle Ninternal Height Of Bottle Ndistance Of Axial Centre Of Bottle Nspeed Nfan Speed Nfan Dimension N 38 Veslic Rub Fastness ( 85 ) - Diameter Of The Cylinder Nextension Graduation Ndistance Travelled By Felt Nspeed Of Motion Nlength Of Side Of Finger Nforce 39 Shank Fatigue Tester ( 232 ) - Cycles Nforce Nload Nfrequency Ndistance Nholder Distance N 40 Crockmeter ( 87 ) - Diameter Of Finger Ncrock Length Ndownward Force 41 Lace To Lace Abrasion Tester ( 92 ) - Moveable Clamp Distance Nmoveable Clamp Speed Nmoveable Clamp To Stationary Clamp Distance Nforce Nspacer Width N 42 Heat Conductivity Tester ( 119 ) - Load Nsurface Area Ntemperature 43 Preparation Jig ( 122 & 122A ) - Distance 44 Plastic Moulding Tools ( 123 A& B ) - Plastic Moulding Tools ( 123 A& B ) - Diameter 45 Clamps For Zip ( 189 ) - Clamp Width 46 Dome Former ( 191 A-F ) - Diameter Nheight Ncurvature Radius 47 Metal Plates And Collars ( 192 A-F ) - Diameter 48 Vamp Flexing Machine With Freezer ( 200, 227 ) - Angle Of V-Shaped Clamp Nradius Of V- Shaped Clamp Nminimum Set Distance Nmaximum Set Distance Nspeed Of Oscillation At 20Oc Nspeed Of Oscillation At -5Oc 49 Bennewart Flexing ( 201 ) - Speed Ndiameter Nlength Nangle 50 Electronic Balance-Sartorius ( 202 ) - Weight 51 Ross Flexes - Room Temp. ( 212 ) - Angle Nflexing Rate N 52 Colour Assessment Cabin ( 239 ) - Angle Nintensity 53 Dynamic Compression Tester ( 221 ) - Speed Nforce Nroller Diameter Nroller Distance 54 Shrinkage Tester ( 222 ) - Temperature Rate Ntemperature Nvolume 55 Force Gauge ( Tensile & Compression Mode ) ( 226 ) - Force 56 Weighing Balance_Mt-At10_ ( 252 ) - Load 57 Oven_Lab Companion ( 297 ) - Temperature 58 Muffle Furnace_Semco ( 318 ) - Temperature 59 Weighing Balance_Mt_Me 204 ( 327 ) - Weight 60 Weighing Balance_Mt_Ag 204 ( 328 ) - Weights 61 Moisture Analyzer_Mt ( 292 ) - Weights 62 Oven_Tempo ( 402 ) - Temperature 63 Dynamic Water Penetration Tester ( 234 ) - Force Nweight Ncycles Ndiameter Nwidth Nmotion Amplitude 64 Bottom Leather Sole Abrasion Machine ( 235 ) - Load Ncycles Nstroke Length N 65 Whole Shoe Flexing Machine ( 236 ) - Flexing Rate Nflexing Angle 66 Perspiration Meter ( 240 ) - Load Nplate Dimension N 67 Hot Plate ( 310 ) - Temperature 68 Shaking Water Bath ( 315 ) - Temperature Nrpm 69 Refrigerator ( 270 ) - Temperature 70 Refrigerator ( 416, 417 ) - Temperature 71 Temperature & Humidity Chamber ( 241 ) - Temperature Nhumidity N 72 K Type Thermocouple ( 275 ) -30°C- 1100°C - Temperature Nvoltage 73 Hygrometer ( 369-379 ) - Temperature Nrh 74 Radius Template ( 228, 226A ) - Radius 75 Vernier Caliper ( 225 ) - Length 76 Stop Watch ( 204, 205 ) - Time 77 Thickness Gauge ( 88 ) - Applying Pressure Npressure Foot Diameter N 78 Thickness Gauge ( 89 ) - Diameter Napplying Pressure 79 Durometer ( Shore A, B, Do, D, O ) ( 68, 69 ) - Spring Force ( A, B, O ) N0, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100 N Nspring Force ( C, D, Do, Oo ) N10, 20, 30, 40, 50, 60, 70, 80, 90, 100 N Nspring Force ( M ) N0, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100 80 Thickness Gauge ( Outsole ) ( 35 ) - Pressure Between Foot And Anvil, Kpa 81 Horizontal Shaker ( 304 ) - Rpm Nrate N 82 Orbital Shaker ( 308 ) - Rpm Nrate 83 Orbital Shaker ( 276 ) - Rpm Nrate 84 Ultrasonicator ( 313 ) - Temperature Ntime 85 Dial Gauge ( 425A ) - Load 86 Steel Scale ( 428 ) - Dimension 87 Lux Meter ( 433 ) - Lux 88 Digital Protractor ( 434 ) - Angle 89 Ross Flexing ( Cold ) Machine ( 435 ) - Temperature Nangle Nflexing Rate 90 Digital Tachometer ( 195 ) - Rpm 91 Weight Set In Stainless Steel, From 1 Mg To 5 K ( 107 ) - Weight 92 Digital Portable Thermocouple ( 1T, 2T, 3T, 4T, 6T, 7T ) ( 97 ) - 1T N2t N3t N4t N6t N7t 93 Slip Gauges – Grade 1 ( 101 ) - Thickness 94 Temperature And Humidity Sensor ( 103 ) - Temperature Nrh N 95 Steel Rule 30 Cm ( 104 ) - Length 96 Steel Rule 1000 Mm ( 105 ) - Length 97 Vernier Caliper ( 106 ) - Length 98 Angle Meter ( 210 ) - Angle
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
20.
Health and Family Welfare #10433257 Price Bid
Supply Of Machine, Equipment And Others , List Of Machine And Equipments , Laproscopic Hd Camera Brand - Karl Storz/Conmed/Olympus Technical Specification Resolution: 1920X1200 Pixes / 1900X1000 Pixes Cable Length: 300 Cm , Ultrasonic Harmonic Scalpel Brand - Johnson Technical Specification Dimensions: (Hxwxd) 5.3 14.5X15.2 Voltage: 100-240 Vac Frequency: 50/60 Hz Rated Current: 3 Amp , Ultrasonic Harmonic Scalpel Brand - Valley Lab Technical Specification Macrobipolar/Bipolar: 473 Khz Sinusoid, 100% Duty Cycle. Seal: 473 Khz Sinusoid Pulsed , Hand Instruments For Laproscopy Brand- Karl Storz/ Olympus Technical Specification I) Veress Needle: It Should Be With Spring Action Blunt Style -12 Cm: 1 No 10 Cm: 1 No 8 Cm: 1 No Ii) Trocar And Cannula:10 Mm: 2 Nos 7 Mm: 1 No. 5 Mm 6 Nos It Should Consists Of Trocar, Cannula With Insufflation And Multifunctional Valve And Must Have Pyramidal Tip. Iii) Reducer/Reduction Sleeve 5 Mm. 1 No Iv) Telescopes: 10 Mm- 0°- 1 Nos -30? - 1 Nos5 Mm-30? 1 Nos Rigid Rod Lens System Provides Good Resolution And The Better Dept Perception. It Should Have Uniform Image Brightness And Autoclavable. The 300 Forward Oblique Angle And Permits For Greater Latitude For Viewing Underlying Areas Under Difficult Anatomical Conditions. V) Suction Cannula: 10 Mm - 1 No 5 Mm -1 Nos Vi) Laparoscopic Scissors: Curved (Monopolar Metzenbaum Dissector 5Mm Diameter): 1 Nos Straight (Bipolar):1 Nosperitoneal Scissor: 1 Nosvii) Unipolar Forceps (Hook & Spatula): 2 Nos Viii) Bipolar Forceps : 2 Nos Ix) Atraumatic Forceps: Maryland Dissector Forceps: : 2 Nos. Fenestrated Forceps: : 2 Nos. X) Needle Holder (Flat Jaw) With Handle : 2Nos Xi) Monopolar Cable (Reusable):1 Nos. Xii) Bipolar Cable (Reusable): 1 Nos Xiii) Allis (Double Row Of Teeth) Grasper: 1 Nosxiv) Aspiration Needle: 1 Nos. Xv) Reducer/ Reduction Sleeve (5Mm): 1 Nos Xvi) Grasping Forceps (Toothed & Rachet 5Mm): 2 Nos Xvii) Laparoscopic Knot Pusher: 1 Nos Xviii) Clip Applicator (Reusable): 5Mm -: 1 Nos : 10 Mm: Ino Xix) Uterine Manipulator: 1 Nos Xx) Clips( Medium & Large) Xxi) Drilling Needle:1 Nos Xxii) Infiltration Needle: 1 Nos Xxiii) Biopsy Forceps (Toothed Punch Biopsy): 1 Nos Xxiv) Myoma Fixation Screw: 2 Nos Xxv) Tissue Morcellator With Base Unit & Accessories: 1 Nos , Dual Wavelenght Laser Brand- Zeiss Technical Specification Laser Type: Diode, Semiconductor Wavelength : 1470Nm+635Nm Max Power: 15 Watts/1470Nm+5Mv/635 Aiming Beam : 635Nm/1, 4Mw Max Or 515Nm/2, 5Mw Max Operation Mode : Continuous Or Modulated Pulsed Time : 0.05Ms-1000Ms Beam Delivery : Sma905 Connector Optic Fiber Compatible : Optic Fibers Having A Core From 200Um To 1000Um, Na=0.22~0.48 Beam Emission Initiation : Footswitch Controller :Microprocessor Display : 10.1 Ips With Touch Panel Medical Approved Cooling :Internal, Air And Thermoelectric Cooling Power Supply Of The Laser: Dc 24V/8.33A From The Separate Ac Power Supply Of Ac Adapter : Single Phase 100-240Va; 50-60Hz, Max 90W Ac Adapterdc 24V/8.33A Medical Approved Laser Dimensions: 27Cm*24,5Cm X 9Cm Laser Weight: 2.75Kg Laser Case Dimensions : 53Cm X 38Cm X 23Cm Weight Of Laser With Cases : 9Kg Environmental Conditions During Work : From +10 To 24°C Degree, Relative Humidity From 30% Up To 60% Cass Of Medical Deviceiib Laser Safety Class 4 Electric Safety Class I Type B Housing Protection Degree Ip20b , Hd Camera Set Brand- Karl Storz/ Olympus Technical Specification (I) Hopkinsa® Forward-Oblique Telescope 30A, Diameter 4 Mm, Length 30 Cm, A Utoclavable, Fiber Optic Light Transmission Incorporated, Color Code Ed :1 Nos (Ii) Telecam C3 : 1 Nos (Iii) Image1 St™ Hx One-Chip Full Hd Camera Head, 50/60 Hz, Fixed Focus, Prog Ressive Scan, Soakable, Gas-And Plasmasterilizable, Focal Length F = 16 Mm, 2 Freely Programmable Camera Head Buttons, For Use With Image1 X-Link Tc301, Tele Pack + And Tp101 : 1 Nos (Iv) Medical Grade Surgical Monitor - Fhd : 1Nos (V) Cold Light Fountain Power Led 175 Scb, With Integrated Karl Storz-Scb, High-Performance Led And One Karl Storz Light Outlet, Power Supply 11-240 Vac, 50/60 Hz Including: 400 A Mains Cord 20090170 Scb Connecti G Cable : 1Nos (Vi) Fiber Optic Light Cable, With Straight Connector, Extremely Heat-Resi Stant, With Safety Lock, Diameter 4. 8 Mm, Length 250 Cm :1 Nos , T U R P Set Brand-Olympus Technical Specification (1) Cystoscope-Urethroscope Sheath, 22 Fr :1 Nos (2) Telescope Bridge, With 1 Lockable Channel, For Use With Cystoscope Sheaths : 1Nos (3) Working Element, E 1 Working Element (Also For Use With Optical Urethrotome) 2 Cutting Loops2 Coagulat Ng Electrodes 2 High Frequency Cords 1 Protection Tube . The Thumb Support Is Movable. In Rest Position Th Electrode Is Inside The Sheath.:1 Nos (4) Resectoscope Sheath, 26 Fr, 1 Nos (5) Schmiedt Visual Obturator, : 1 Nos (6) Cutting Loop Angled, 24/26 Fr., Units Of 6 : 1Nos Ellik Evacuator:1 Nos (7)Urethrotome Sheath, 21 Fr. Urethrotome Sheath And 2 Luer-Lock Cones.:1 Nos (8) Obturator, For Urethrotome Sheath, 21 Fr.1 Nos Sachse Cold Knife, Straight, Not To Be Used With Hf Current This Artic Le Is Only Available In Units Of 6 :1 Nos , Flexible Cystoscope Brand-Olympus Technical Specification Cysto-Urethro-Fiberscope, With Contrapositive Deflection Mechanism, De Flection Of Distal Tip 210°/140, Direction Of View 0°, Angle Of View 10, Working Channel Inner Diameter 7 Fr., Sheath Size 15.5 Fr., Worki G Length 37 ??, Consisting Of: 11272 Cu1 Cystourethro-Fiberscope 2767 A Case 27023 Fe Grasping Forceps 27023 Ze Biopsy Forceps 13242 Xl Lea Age Tester 11025 E Pressure Compensation Cap 27651 B Cleaning Brush 27 14 Y Lueradaptor , Echocardiography Brand-Ge Healthcare/ Philips / Siemens Healthcare/Bpl Technical Specification A) 2D, M-Mode, Colour M-Mode B) Colour Flow Doppler Imaging C) Fully Steerable Pulsed Doppler D) Fully Steerabie Continuous Wave Recall E) Digital Cine Replay Of All Imaging And Doppler Modalities. F) On Screen Cine Storage & Image Recall G) Digital Image Storage And Patient Archive With True Scanner Frame Rates. H) Full Measurement And Analysis Capabilities. Both On Line And Offline Preferable. I) Imaging Frequencies From 1 Mhz To 15 Mhz J) Review Of Stored Ultrasound Images. K) User Adjustable B Colorization Maps, Gain Settings, Colour Doppler Baseline, Angle Correction And Other Important Parameters With Live/Frozen/Archived Images/Loops. , 12 Lead Ecg Machine (Brand - Bpl/Maestros) Technical Specification Electrocardiograph Should Have Capability Of Recording 12-Lead Ecg And Should Have The Following Features: 1. Should Have Simultaneous Acquisition Of 12 Leads 2. Should Have A Display To Preview The Ecg Waveform Before Printing 3. Should Have 7 Inch Or More Display With High Resolution Screen 4. Should Be Compact, Portable And Easy To Operate 5. Should Have Keyboard For Manual Entry Of Patient Data 6. Should Have Provision For Providing Hospital Name On The Printed Record7. Should Work On Li-Ion Battery8. Should Have A Frequency Response Of 0.01-300 Hz 9. Should Have Sampling Frequency Of 15,000 Hz Or More10. The Device Should Weigh Less Than 5.5 Kgs With Battery11. Should Have A Special Arrhythmia Triggered Mode Of Printing12. Should Have Pacemaker Detection Facility 13. Should Be Able To Record On Different Modes Of Sensitivity: 2.5,5,10,20 Mm/Mv & Agc14. Should Have Different Recording Speeds: 5, 10, 12.5, 25 And 50 Mm/Sec15. Should Have Different Filters Available For Smoothing Of Waveform16. Should Have Ac Filter, Emg Filter: 25 Or 35 Or 45 Hz Or Off17. Should Have Anti-Drift Filter18. Should Have Different Print Formats: 3/6/12, 3X4 With Rhythm Leads, 6X2, 12X119. Should Have A Large Storage Of 700 Ecgs Or More20. In Case Of Error In Lead Connections, The Machine Should Display The Change In Color Of Particular Lead.21. Should Be Able Transfer Data Directly In Pdf Format To Usb22. Should Be Able To Printout Records On Thermal Paper As Well Z-Fold23. Should Have Facility Of Printing In Automatic/ Manual/ Rhythm/ R-R Mode Of Printing24. Should Have Facility For Interpretations And Measurements25. Should Provide Detailed Printout Of Patient Data26. Should Have Paper Of Minimum Width Of 210Mm27. Should Have The Capability To Generate Any Number Of Ecg Copies For Distribution28. Should Be Able To Connect To Pc 29. Should Be Able To Operate To A Maximum Of 4 Hours On A Newly Charged Battery30. Should Have Direct External Printer Connectivity31. The Unit Should Be Portable And Should Be Able To Carry With Help Of A Handle.32. The Product Should Be Ce Certified33. The Manufacturer Should Be Iso Certified34. The Device Should Be Provided With Standard Accessories:A) Ecg Cable (Adult)-1 Nob) Gel Bottle- 1 Noc) Chest Electrodes (Set Of 6)- 1 Nod) Limb Electrodes (Set Of 4)- 1 Noe) Z-Fold Paper - 1 Packf) User Manual-1 No , Multipara Patient Monitor(Brand - Drager/Penlon/ Bpl) Technical Specifications For Multipara Monitor 1. Multiparameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,(Massimo),Nibp (Suntech) Temperature.3. Optional Parameter Etco2, Dual Ibp, Agm 4. Should Have12-Inchcolor Lcd Display.5. Should Have Dual Modes Of Operation: Rotary Knob.6. Should Display 7 Waveforms Or More7. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen.8. Ecg: Should Be Able To Monitor Ecg Through 5-Lead Patient Cab Should Have Manual St Analysis Window ,Should Detect 20 Arrhythmias And Generate Alarms. , The Priority Of Arrhythmia Alarms Can Be Configurable, Should Measure Pvc &Pac Should Be Able To Monitor Heart Rate From 10-300 Bpm Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etcshould Have Pacemaker Detection Facility Respiration: Measurement Range Of 0 To 150 Breaths Per Minshould Have Gain Selection: ×0.25, ×1, ×2, ×4 Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S Should Have Apnea Detection Facility Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 10 Spo2: Should Have Massimo Technologyshould Have Measurement Range Of 0~100 % Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph Should Be Able To Select Sat Sec To Avoid False Alarm 11. Nibp: Must Be Of Suntech Medicaltechnology For Clinical-Grade Blood Pressure Measurement Have Auto, Manual, And Stat Modes Of Operation For Nibp. Should Have A Measuring Range Of 0-280 Mmhg Should Have 2 Channels For Temperature Monitoring Should Have Data Storage Capabilities:72 Hours Of Trend Data Storage. , Bp Machine Brand - Pagoda/ Omron/ Platinium/ Dr Trust/Bpl Technical Specification Should Be Able To Measure Blood Pressure And Pulse Rate In Adult As Well As Pediatric Patients. Should Be Based On Oscillometric Measurement Technology, Using Dynamic Linear Deflation Method. Should Have Backlight Lcd Display With Easy To View Readings In Dim Light. Pressuremeasurement Range Should Be 60 To 250Mm Hg Systolic, And 40 To 200Mm Hg Diastolic. Pressure Display Accuracy Of +/- 3 To 5 Mm Hg Pulse Rate Measurement Range Of 40 To 200 Per Minute Pulse Measurement Accuracy Of Within 5% Should Include Ac Adapter (Input Range 100-240V And Output Voltage Dc 6V), Preferably With Rechargeable Battery (3.6V To 4.8V, 1900 To 2400Mah) Cuff (22 To 32 Cm Size) Should Be Supplied With Standard Adult Size Single Button Operation For Start And Stop Functions With Auto-Inflation Of Blood Pressure Cuff. , Ventilator Brand - Drager/Bpl/Medisys Technical Specification 1. The Ventilator Should Be High-Endventilator Suitable For Ventilating To Adult And Pediatric Application. Should Have Advanced Microprocessor Control System With Individual Selection Of Various Ventilation Parameters. 2. The Unit Should Be With Altitude Compensation For Volume And Btps Correction For Monitoring3. The Unit Should Be Of Wall Independent Gas Delivery System. Demonstration Of The Equipment Is A Must Demonstration Of The Equipment Is A Must4. Should Have Facility For Invasive And Non-Invasive Ventilation;5. The Ventilator Should Have 12” Or More Lcd Screen With Touch Facility For Display Of Waveforms. Should Have Brightness Modes Like Day/Night-Mode. The Real Time Display Of All Parameters/Waveforms Should Be Clearly Visible From All Angles6. Should Have Modes Of Ventilation Equipped With Newer Modes Of Ventilation:A) Assist/ Controlb) Volume Control Modes: Vcv, Vc-Simv, Plvc) Pressure Control Modes: Pcv, Pc-Simv, Bi-Level, Bilevel-St, Pc-Aprvd) Spontaneous Ventilation Modes: Psv, Cpap, Bilevel /Similar, Bilevel St / Similare) Prvc/Pcv-Vg/Dynamic Bilevel/Or Its Equivalent Modef) Closed Looplung Protective Mode- Asv/Nava/Wobov/Alpv/Smart Care (At Least 1 Of The Mentioned Mode Is Mandatory)G) Should Have Pav (Proportional Assist Ventilation) / Pps (Proportional Pressure Support)/ Paps (Proportional Adaptive Pressure Support)H) Cpr (Resuscitation Mode),I)Niv In All Pressure Modes7. Hfot /Nasal Cpap Breathing Therapy Should Be Capable Of Adjusting The Range Up To 60Lpm8 A) Apnea Backup Ventilation In All Modes8 B) It Should Have Weaning Analyzer Tools : Sat & Sbt9. Should Have In-Built Nebulizer With Capability To Deliver Fine Particle Size Of To Be Used In Line10. Should Have Facility To Measure And Display The Following Parameters:A) Airway Pressure (Peak & Mean)B) Tidal Volume (Inspired & Expired)C) Minute Volume (Expired)D) Spontaneous Minute Volumee) Total Frequencyf) Fio2 Dynamicg) Intrinsic Peep, V Trap & Time Constant (Rcexp)H) Resistance & Compliance11. Automatic Compliance And Leakage Compensation For Circuit And Et Tube 12. Should Have Facility Of Logbook, For Events And Alarms With Date & Time 13. Should Have Following Setting & Monitored Parametersa) Tidal Volume; Pre-Set Range For Both Pediatric & Adult Modes To Be Providedb) Inspiratory Pressure (Up To 100Cm Of H2o);C) Respiratory Rate 1 To120 Bpm;D) Apnea Back Up Rate;E) Peep: 0-50 Cmh2of) Inspiratory Flow: 0-120 Lpmg) Max Peak Flow : 280 Lpm Or Betterh) O2 Concentration: 21-100%I) Pressure Support: 1-(100-Peep) Cmh20j) Fio2 Setting Range Between 21% And 100%;K) Pressure Flow & Volume Curves;L) Loop For V-Flow, Flow-P, Flow-Paw And At Least 5 Storage Spaces For Reference Loopsm) I: E Ratio: 150:1 To 1: 299N) Ramp Time: Up To 3 Seco) Inspiratory Time: 0.2 To 15Sp) Pause Time; Exp/Insp Holdq) Pressure Trigger: Up To -10Cmh2o And Flow Trigger Up To 20 Lpm;R) I Flow/T Plateaus) Resistance & Compliance (Cdyn & Cstat)T) Leakageu) P Plateau 14. Should Have Weaning Parameters;Rsbi,Vt Spont, R Spont ,Vt/Ibw15. Should Have Weaning Parameters;Rsbi,Vt Spont, R Spont ,Vt/Ibw16. Facility To Calculate Lower And Upper Inflection Point (P/V Flex Points)Should Have Recruitment Manoeuvre17. Should Have Automatic Suction Routine & O2 Flush18. Should Have A Dedicated Bronchoscopy Function To Allow & Compensate Ventilation While Performing Bronchoscopy19. Should Have Trend Of 7 Days And Above With Facility To Transfer Through Usb Interface20. Alarms Should Be User Friendly, Audio And Visual With Text Message, System Alarm Should Be For:A) Pressure Changes (High/Low)B) Tidal Volume Changesc) Minute Volume Changesd) High Peepe) High/Low O2 Concentrationf) Power Failure And Low Batteryg) Patient Disconnectionh) Apnea 21 A) The Ventilator Should Have Facility For Co2 Monitoring. Should Have Inbuild Etco2 Interface & Software To Accommodate External Optional Volumetric Etco2 In Future21 B) Should Be Upgradable To :Metabolic Monitoring (Indirect Calorimetry).Price To Be Quoted As Optional.22. The Ventilator Should Not Weigh More Than 12 Kgs 23. Ventilator Should Have In Built Non- Consumable Paramagnetic Oxygen Sensor That Shouldnot Require Change For At Least 5 Years.24. Flow Sensor Should Be Differential Pressure Technology, Or Ultrasonic.Flow Sensor Must Be At Expiratory End. Should Be Maintenance Free, Reusable And Autoclavable.The Flow Sensor, Inspiratory Port, Expiratory Port Should Be Easily Removable Without Using Any Tools & Should Be Autoclavable.25. Should Have Usb /Serial Interface For Communications With Networked Devices26. The Ventilator Should Have On Screen Help Menu For Alarm, Ventilation Mode & Ventilator Settings. The On Screen Help Menu Should Guide User On Solving The Alarms; Providing Information On Ventilation Modes & Settings. 27. Should Support Dual Limb Circuits Of Any Make And Not Ventilator Model Specific Circuits28. The System Should Have Inbuilt Rechargeable Battery With Backup With Minimum 2 Hours29. Power And Gas Requirements: A) Power Input To Be 220-240Vac, 50Hz (100-240 Vac) B) Gas Input (Air And Oxygen) - 29-100 Psi (29-87 Psi)30. The Ventilator Should Be European Ce Certified Or Us Fda Approved, And The Manufacturing Company Should Be Iso Certified.Accessories/Consumables To Be Supplied With Main Unit I. Icu Ventilator With Trolley – 1Nosii. Reusable Adultcircuit - 1 Nos Iii. Hinged Support Arm – 1 Nosiv. Hme Filters—5Nosv. Bacterial Filters-5Nos Vi. Hepa Filetr-1Nos Vii. Test Lung -1Nos Viii. High Pressure Oxygen Inlet Hose – 1Nos , Projector With Screen Brand - Epson / Benq / Lg Cinebeam Technical Specification Ce Marked, Power Supply: 220-240 V Ac, 50/60 Hz, Transparent Lcd Panel Display System, Minimum 5200 Hours Lamp Life, Min. 5800 Lumens Brightness, Contrast Ration 10000: 1, Aspect Ratio 16: 10, Resolution Xga (1024 X 786) With Hdmi And Vga In, Lan & Usb Support, Wireless Support, Light Weight, Remote Control Etc. , Phaco Emulsifier Machine Brand-Alcon Legion / Zeiss Technical Specification 1. Operating Frequency Should Be Approx. 40 Khz 2. Handpiece: Ultralight Ultrasound 4 Crystal Piezoelectric Hand Piece. 3. Us Modes: Continuous, Pulse, Single Burst, Multi Burst, Continuous Burst, Automated Programmable Modulation (Apm) 4. Automated Ultrasound Power On Demand: Ultrasound Management Technology That Automatically (De)Activates Ultrasound Us Delivered Only When Needed Ept Up To 50% Less & Better Followability. 5. Type Of Infusion: Iop Controlled, Synchronized Fluid Exchange System That Directly Measures And Simultaneously Controls Both Infusion And Aspiration Volumes In Real-Time. It Actively Compensates For Incision Leakage. Quattro Controlled Forced Infusion. 6. Display: 24 Inches Touch Screen. 7. Iop Range: 30-120 Mmhg 8. Vacuum Range 0 To 700 Mmhg 9. Aspiration Flow Rate 0 To 120 Cc/Min 10. Aspiration Control Modes: Vacuum Controlled Mode, Flow Control Mode 11. Chamber Stability: Irrespective Of Type Of Cataract, Surgical Conditions, Leakage (0 -12 Ml/Min) It Keep Chamber Stable & Maintain Targeted Iop Throughout Procedure. 12. Iop Recovery Time After Occlusion Break 200-250Ms For Vacuum In Range Of 200 -600Mmhg. 13. U/S Tips: Coaxial Phaco With Incision Size 2.2 Mm 14. Vitrectomy: Pneumatic Cutting Device15. Type Of Vitrectomy Cutter: 23G Anterior Vitrectomy Cutter16. Anterior Vitrectomy Range:Cut Rate 30 To 5000 Cuts Per Minute. 17. Actuation Medium For Vitrectomy: Compressed Air From Internal Source 18. Diathermy: Bipolar With Fixed And Linear Control Via Foot Pedal. 19. Type Of Diathermy Handpiece: Diathermy Forceps And Diathermy Pencil Eraser. 20. Instrument Tray Arm Length: Should Be 800Mm Or More. 21. Dual Linear Footswitch 22. Should Be Usfda And Ce Approved 23. Online Ups Should Be Providedaccessories: Phaco Hand Piece(Coaxial) -2 Coaxial Handpiece Tip I – 2 I/A Bi Manual Hand Piece – 2Phaco Tip (2.2 Mm)- 10 Phaco Sleeve (Silicone)(2.2Mm) – 10 Test Charnber- 10 Tubing And Cassettes (Disposable) – 100 Diathermy Cable With Forceps – 2 Phaco Wrench-2 Vit Cutter- 23 G; Single Use – 6Sterilization Container/ Tray , Autorefractometer & Keratometer (Ark) Brand-Zeiss- Visuref 150 Technical Specification (A)Device Data.(A) Refraction(1) Sphere -25.00D To +22.00D (In Steps Of 0.12D/0.25D)(Ii) Axix 0 To 180*) (B) Keratometer(A) Corneal Curvature 5.00 To 10.20Mm (In Steps Of 0.01Mm)(B)Corneal Redraction-33.000 ?? 67.50D (In Steps Of 0.12D/0.25D)(C) Corneal Astigment-0.00D To-15.00D50d (In Steps Of 0.12D/0.25D)(D)Axis 0 To 180* (In Seps Of 1*) (E) Corneal Diameter (2.00 To 1200Mm (In Steps Of 0.10Mm) , Humphrey Fied Analyzer ( Hfa3) Brand-Zeiss Technical Specification • High Quality Goldman Standard Automated Full Field Perimetry Of International Standard With Bowl Size Radius = 30Cm. • Computer & Monitor Should Be Integrated In The Perimeter (No External Computer). • Stimulus Size I, Ii, Iii, Iv & V.• Background Illumination 31.5Asb.• Maximum Temporal Range 80Deg.Suitable For Central 30, Neurological Tests As Well As Full Field Testing. • Central Field Test Patterns 30-2, 24-2,10-2, Macula.• Peripheral Field Test Pattern 60-4, Nasal Step, Custom Test. • Threshold Test Strategies Full Threshold, Sita Standard, Sita Fast , Full Threshold, Fast Pack, Sita - Swap.• Screening Field Test P-60, Ff-80, Ff-120, Ff-240,Nasal Step For Periphery .• Screening Test Strategies Two Zone, Three Zone And Quantify Defects.• Glaucoma Hemi Field Test, Heijl –Krakau Blind Spot Monitor• Video Eye Monitoring, Gaze Tracking Monitoring System, .. Vertex Monitoring And Head Tracking. • Touch Screen On Crt Monitor, Keyboard & Provision Of External Monitor & Keyboard.•Internal Hard Disk Drive.• Stimulation Duration 200Ms, Wavelength Broad Band Visible Light• Stimulus/Background Colour White On White.• Swap (Blue On Yellow) Perimetery. • Auto Pupil Measurement. • Kinetic Testing & Custom Kinatic Testing. • Motorised Chinrest, Motorised Table, Laser Jet Printer • Glaucoma Progression Analysis ( Gpa ) Software For Monitoring Disease Progression. With Visit Wise Graph &Visual Field Index (Vfi).• Releye Monitor.• Forum Software For Archiving & Offline Analysis Of Patient Data & Gpa Analysis Etc.• Hfa Dicom Gateway. , Laser Dcr Brand-Medfin Technical Specification Applicationsdacryocystorhinostomy Amplifying Medium Diode Ergonomics Tabletop Wavelength-980Nm Average Power -8W Weight -1.2Kg (2.65Lb) , Automatic Tourniquet System With Hose Cuffs Brand - Zimmer Biomet (Model Ats-5000) Number Of Ports Dual Port Number Of Potential Cuffs Dual Cuff Dual Cuff Mounting Options Table Or Pole Mount Table Or Pole Mount Battery Type And Life Lithium Ion 6 Hrs Lithium Ion 6 Hrs User Interface Touchscreen Touchscreen International Alarm Standard 60601-1-8 Compliant Compliant Display 10.1” Color 7.0 Color Minimum/Maximum Pressure 20/600 Mmhg 50/600 Mmhg Pressure Accuracy ±3 Mmhg (20–600 Mmhg) ±4 Mmhg (50-600 Mmhg) Limb Occlusion Pressure (Lop) Allows For Patient Specific Pressure, Which Allows For The Minimum Pressureto Be Used.Yes Noline Occlusion Detection (Acoustic Reflectometry)A Kinked Pneumatic Tube Can Prevent An Inflated Cuff From Deflating, Resulting In Unintentional Tourniquet Pressure. This Alarm Alerts Or Staff That There Is An Occlusion In The Line To The Cuff.Yes , Battery Opreated Heavy Duty Drill & Saw Brand -Manman/Biotech Specifications--- Drill And Reamer Hand Piece Attachments, Oscillating/S Reciprocating Saw Hand Piece Charger And Sterilization Handpiece For Drilling & Reamingtrigger Type Single Modes Available - Reverse & Forward Modedrill Speed 1000 Rpm Approxdrill Torque 4 Nm (35+ In Lbs)Ream Torque 16.5 Nm (145+ In. Lbs)Weight Of Hp With Batteries 1250 Gms Drilling And Reaming Attachments Hudson/Zimmer/Trinkle Reamer Attachment - Yesao Reamer Attachment - Yesao Type Drill Attachment With Quick Coupling - Yesjacobs Chuck With Minimum 6 Mm - Yeskeyless Chuck -Yes Wire Driver Attachment - Yespin Driver Attachment - Yes Dhs Reamer Attachment With Quick Coupling - Yesoscillating/Sagital Saw Hand Pieceergonomic Pistol Grip Design For Maximum Comfort And Control Yes Weight Of Hp With Batteries.- 1350 Gmssaw Speed - 15000+ Cpmcutting Arc - Between 4 To 5 Degreenoise Level - 60-85 Dblspecial Blades Each For Tkr And Thr (Nos) - 10 Battery Specifications Type Of Battery Lithium Ion (Li-Ion) Number Of Batteries 2 , Electric Cautery Machine Brand - Shalya/Enertech/Eclipse/Valley Lab 1) Unit Should Have Microprocessor-Controlled Tissue Feedback Technology 2) Unit Should Have No Of Bipolar Modes Available 3) Unit Should Have Pure Sinusoidal Output Waveform In Hf Power Output In Cut And Bipolar Modes. 4) Type Of Display Should Be Lcd Touch Screen 5) It Should Adjust Power Level Automatically Depending On Tissue Type. 6) It Should Have Two Monopolar Output Channels. 7) Bipolar Current Meter Bipolar Current Meter 8) Unit Should Deliver Two Coagulation Output At A Time With Independent Control Over Each Output For On & Off. 9) Both Channels Should Work By Foot And Hand Control. 10) It Should Complete Self Testing During Power On. 11) Power Efficiency 98 Or More Than 98 12) Availability Of Advance Cutting Modes For Regular Open Surgery 13) It Should Accept Disposable And As Well As Reusable Patient Plate. 14) Unit Should Have Tissue Feedback, Pulsed Interval-Controlled Pulse Cut Function. 15) It Should Accept Dual Area And Single Area Patient Return Electrode. Should Give Green Indication If Dual Area Patient Plate Applied To Patient & Red Indication With Alarm Tone If The Patient Plate Is Not Applied. 16) Bipolar Should Work Without Patient Plate Or Patient Plate Error Condition. 17)Bipolar Should Have Auto Facility To Start & Stop Working Without Footswitch. 18) Unit Should Have Adjustable Delay Activation In Auto-Bipolar. 19)It Should Have Randomized Spray Coagulation For Larger Area Coverage.20)It Should Be Upgradeable For Argon Delivery Module From The Same Oem.21) Unit Should Be Useful For Underwater Procedures. 22) It Should Have Alarm Facility After Completion Of Bipolar Coagulation. 23) Unit Should Have Time Out Function For Automatic Stop The Hf Output If Prolong Unintended Activation. (Optional)24) Unit Should Have Touch Key Pad For Power And Mode Selection.25) System Should Give Error For Faulty Handswitch Of Footswitch In Monopolar & Bipolar.26) Unit Should Give Error For Faulty Keypad. 27) It Should Have No Of Segments Of Display 3. 28) Unit Should Operate From 180 V To 265 V Without Using External Stabilizer. 29) It Should Have Independent Foot Switch For Monopolar Two Paddle. 30) It Should Have Independent Foot Switch For Bipolar Single Paddle. 31) Unit Should Have Facility To Connect Either Monopolar & Bipolar Footswitch.32) Unit Should Have Remote Power Setting Facility From Sterile Field With Conventional Hand Switching Pencil. 33) It Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification. 34)Manufacturer Iso 9001: 2008 & En Iso 13485:2012 Certified Company.35) Warranty Must Be 3 Years Or Higher 36) It Should Be Supplied With Following Reusable And Autoclavable Accessories: -1. Patient Return Electrode …………………….1 No.2. Hand Switching Pencil………………………. 1 No.3. Foot Switching Pencil…………………………1 No.4. Bipolar Forceps …………………………………1 No.5. Cable For Bipolar Forceps……………………1 No.6. Monopolar Footswitch ………………………1 No.7. Bipolar Footswitch ……………………………1 No. 8. Universal Adaptor …………………………….1 No.Set Of Electrode (Angled, Ball And Needle).1No10. Trolley With Lockable Castor Wheel Should Be Supplied1. Unit Should Be Eu Ce (4 Digit Notified Body Certified)2. All Sockets Should Be Of Blinking Light Type When In Use To Identify The Used Mode 3. Availability Of Test Report From Central Govt/ Nabl/Ilac Accredited Lab Covering All Parameters. And Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification. , Arthroscopy Set (Brand- Smith +Nephew / Karl Storz) Arthroscopy Set 30° (Arthroscopic, Sheath And Obturator) Wide Angle, Direct View 4K High Definition Arthroscope. Light Guide Insertion On Definitione Direction View With A J-Lock Fixation For Cannula.Working Length Of Not More Than 160Mm Optimal Centre-To-Edge Resolution For Enhanced Picture Quality Angle Of View: 30 Degree Diameter: 4Mm Arthroscopies Should Be Supplied With Compatible Cannulas High Flow, Double Valve, Fully Rotatable With Fenestrated Tip & Conical And Blunt Tip Obturator, Sheath- 5.95 To 6.0Mm, High Flow Diagnostic Cannula, Double Valve, Fully Rotatable Cannula With Fenestrated Tip. Trocar-4.5Mm Conical Obturator To Fit With Cannula. Arthroscopy Set 70° (Arthroscopic, Sheath And Obturator) Wide Angle, Direct View 4K High Definition Arthroscopic Light Guide Insertion On Opposite Side Of The Direction Of View With A J-Lock Fixation For Cannula. Fully Rotatable With Fenestrated Tip & Conical And Blunt Tip Obturator. Sheath- 5.95 To 6.0Mm, High Flow Diagnostic Cannula, Double Valve, Fully Rotatable Cannula With Fenestrated Tip. Trocar-4.5Mm Conical Obturator To Fit With Cannula. Arthroscopic Power Shaver System: Input Voltage Of 100 To 240V, 50/60 Hz Power Consumption Not More Than 350Va. Two Separate Receptacles For Motor Drive And Powered Instrumentation. Shaver Should Have 2 Modes Of Oscillation For Aggressive Cutting Shaver Should Have Button For Flush Lavage Of Joints On Footswitch. Autoclavable Ultra-Light Hand Piece With Suction Facility, With 3 Hand Control Buttons And Replaceable Cable Long 10Ft (3 M). Maximum Torque Should Not Be Less Than 32Oz.In And Weight Should Not Be More Than 212 Gms Pedal Style Footswitch With 3 Operating Modes I.E. Forward, Reverse And Oscillation. On-Line Lcd Display For Speed And Direction Referral. Should Communicate With The Fluid Management System Once Connected With The Cable. Camera Control Unit: System Must Have Inbuilt 4K Uhd Camera Console, Led Light Source & Wifi Enabled Image Management System With Recording Via Usb Port Along With Recording In App Through In Built Wifi. Camera Resolution Must Be 3840*2160 (Native) 4K Camera Head: Camera Head Should Have 4K, 3 Chip Mos Video Sensor Technologymust Have Transport Shock And Vibration Compliance With Ista 3Avideo Field Rate 60 Hz Must Have C-Mount Autoclavable Coupler With 19.5 Mm Coupler Length Opt For 4Mm Scopes Must Have Digital Zoom Video Data Transmission High-Speed, Low-Voltage Differential Serial (Lvds), Digital Transmission Via 12-Foot Camera Cablevideo Output Format Full Uhd 2160P, 100% Compatible With Smpte St-425-5 When Used With The Ccu Altitude: 3000 Meters Maximum 4K Monitor: Monitor Should Have Resolution 4096 * 2160 Pixels Monitor Should Support Picture Size (Diagonal) 789.06 Mm (31 1/8 Inches) 1387.8 Mm (54 3/4 Inches) Monitor Should Support Effective Picture Size 698 * 368.1 Mm (27 1/2 * 14 1/2 Inches)Monitor Should Support Pixel Pitch 0.1704 X 0.1704 Mm Monitor Should Have Aspect Ratio Of 17:09Monitor Should Have Pixel Efficiency Of 0.9999 Size Is -125Mb 1300 Seconds Video / Gigabyte Storage 10000 Images/Gigabyte Storage Airprintt Is Required. , Fess Instruments Set Nus Surgery Fess & Dcr Surgery Instruments Brand -Kalelkar / Besco Blakesley Forceps 0 Blakesley Forceps 45Blakesley Forceps 90° Thrucut Forceps 0Thrucut Forceps 45° Thrucut Forceps 90 Maxillary Sinus Forceps 30, 90, 120Hewiser Forceps Tubular Rotatable Kerrison Punch Straight Kerrison Punch Curved Backbiting Forcep Tubular Rotatable Stammberger Ostrum Punch (Mushroom Forceps)Giraffe Forceps Upturned 55, 70, 90, 110 With Vertical Or Horizontal Opening Fronntal Sinus Bougie Set Of 4Sickle Knife Sharp/Blunt Ball Probe Double Ended Right Angledball Probe With J Hook Double Endedantrum Curette Oval Or Round Cup Suction Canulla 45 Or 90° , Micro Ear Surgery Instrument Set (Ear Surgery Instruments) (Stapedectomy Instruments) Brand -Kalelkar / Besco Technical Specification Sickle Knife , Circular Knife Flag Knife , Sickle And Flag Knife Double Ended , Sickle And Circular Knife Double Ended Circular And Flag Knife Double Ended , House Curette Double Ended, Elevator Pick Straight/Curved/Right Angled , Fisch Perforator 0.3 Mm To 0.8 Mm. Hand Burr , Piston Depth Guage , Stapedectomy Instruments , Piston Cutting Jig Piston Autoclaving Box , Teflon Pistonspistion Crimper Micro Ear Scissor Belluchi Operative Ear Speculam Set Of 4 Black Slotted Or Plain Endural Retractor 2X2endural Retractor Left/Right Plester Micro Suction Canulla 116 To 24Gmicro Suction Canulla Adaptor Silicone Suction Tubecartilage Slicer , Tonsillectomy Instruments Set Brand -Kalelkar / Besco Technical Specification Davis Boyles Mouthgag With 5 Blades Davis Boyles Mouthgag With 5 Slotteddraffin Bipod Stand With Plate Tonsil Holding Forceps Tonsil Dissector Cum Pillar Retractortonsil Dissection Forceps Tonsil Artery Forceps Straighttonsil Artery Forceps Curvedtonsil Artery Forecps Negustonsil Scissor Tonsil Snare Tonsil Snare Wire +Quincy Foreps +Adenoid Curette With Cage + Adenoid Currette Without Cage + Younker Suction Canulla +B.P.Handle No 7 + Negus Knot Tier +Thrroat Instruments Tracheatomy Surgery Instruments + Tracheatomy Tube Chevalier Jackson/Fuller + Mosquito Artery Forceps + B.P.Handle No 3 + B.P. Blade No 11 + Fine Scissor 4 +Tracheal Dilating Forceps + Kilner Catpaw Retractor +Skin Hook + Single Hook Retractor +Double Hook Retractor , Nasal Surgery Instruments Set (Septoplasty Instruments) Brand -Kalelkar / Besco Technical Specificationkillians Nasal Speculam 2 To 3.5 + St. Clair Thomson Nasal Specularm Set Of 4 B.P. Handle No 3+Freersdouble Ended Mucopericondrial Elevator + Symes Double Ended Mucopericondrial Elevator + Howarth Double Ended Mucopericondrial Elevator Symes Double +Suction Elevator + Lucs Forceps Round Or Heart Shape + Jensen Middleton Septum Cutting Forceps + Jensen Middleton Septum Punch Forceps + Turbinectomy Scissor + Ballenger Swivel Knife Bayonet Shape + Tilleys Nasal Gouge Bayonet Shape With V Cut Or. Plain + Hammer (Mallet) + Submucosal Diathermy+ Needle/Ball Probe + Nasal Packing Forceps + Spring Scissor + Catspaw Retractor + Tongue Depressor + Rhinoplasty Surgery Instruments + Raps + Cricoid Hook + Jenkins Chisel + Alar Retractor + Aufritch Nasal Retractor + Ash Septum Forceps + Walsham Septum Forceps + Gillies Osteotome + Nasal Packing Forceps + Silver Nasal Chisel With Guard Left/Right + Skin Hook + Cottle Retractor + S.M.R Instruments + Killians Nasal Speculam 2 To 3.5 + St. Clair Thomson Nasal Speculam Set Of 4 + Freers Double Ended Mucopericondrial Elevator + Symes Double Ended Mucopericondrial Elevator + Howarth Double Ended Mucopericondrial Elevator + Suction Elevator + Turbinectomy Scissor + Ballenger Swivel Knife Bayonet Shape + Tilleys Nasal Gouge Bayonet Shape With V Cut Or Plain + Hammer (Mallet) , Micro Laryngeal Surgery Instruments Set Brand -Kalelkar / Besco Laryngoscope Mls Black Finish Adult/Child/Paediatric With Fiber Optic Carrier Chest Supportlaryngoscope Distending Operating Type Laryngoscope For Filling With Endoscopemls Forceps Cup Type Straight/Left/Right/Upward/Downward Mls Forceps Serrated Type Straight/Left/Right/Upward/Downwardmls Scissor Straight/Left/Right/Upward/Downward Mls Vocal Cord Spreader Mls Mini Larygeal Forceps Triangular End Mld Needle Holdermls Ssickle Knife Mls Circular Knifemls Flag Knifemls Probe 45°, 90°Mls Curettemls Handle For Use With Straight Instumentssuction Tube With Thumb Control Insulated Probe For Coagulationbronchoscope/Esophagoscope & Instrumentsbronchoscope Negue Type Any Size With Fiber Optic Carrier Esophagoscope Any Size With Fiber Carrierhypopharyngoscope (Esophageal Speculam) With Fiber Optic Carrier Forceps Alligator Grasping Single Actionforceps Peanut Soft Tissue Single Actionforceps Cub Biopsy Type Single Action Forceps Patterson Type Single Actionforceps Universal Biopsy & Grasping Single Actionforceps Alligator Grasping Double Actionforceps Peanut Soft Tissue Double Actionforceps Cup Biopsy Type Double Actionforceps Patterson Type Double Actionforceps Universal Biopsy &Ngrasping Double Action Suction Tube Rigid With Thumb Conntrol , Mastoid Surgery Instruments Set Brand -Kalelkar / Besco B.P. Handle No 4 Kilner Catspaw Retractormollison Mastoid Retractor 3X3 Mollison Mastoid Retractor 4X4mahadevaiah Modified Mastoid Retractor Left/Right Jensen Retractorjolls Retractor Periosteal Elevatoroperative Ear Speculam Set Of 4 Black Slotted Or Plain Micro Suction Canulla 11G To 24Gmicro Suction Canulla Adaptor Mastoid Suctioncanulla Set Of 4 With Thumb Grip Sickle Knifecircular Knifeflag Knife House Curette Double Ended Elevator Adsons Toothed Forceps Adsons Non Toothed Forceps Needle Holder 6 Fine Scissor 4Micro Ear Crocodile Serrated Forceps Micro Ear Crocodile Cup Forceps Micro Ear Crocodile Scissors Malleus Nipper Ball Probe 45 Degree/90 Deegre Vien Graft Pressossicle Holding Forceps , Fiberoptic Flexible Video Laryngoscopy System Brand -(Penlon / Karl Storz) Specification 1) It Should Be Very Portable And Light Weight Device With Minimum Display Size Should Be 4 Inch With High Resolution Anti Reflective Display. 2) Should Have 180 Degree Horizontal Screen Rotation With Vertical Movement For Betterclinical Assistance. 3) It Should Be A Lithium Ion Rechargeable Battery-Operated Device With Low Battery Indicator. 4) Minimum Operation Item Should Be 130 Mins. 5) It Should Have Led Light Source At The Tip Of The Blade With Minimum 2 Megapixel Cmos Camera For Better View. 6) It Should Have Channelled And Without Channelled Blade Option. 7) Should Have 4Gb Inbuilt Memory For Continuous Recording & Image Capturing. 8) Blades Sizes Should Be Size 1,2, 3, 4,5 . 9) Blade Should Be Affordable, Sterile Which Connect Laryngoscope Handle With Lock. 10) Battery Life Cycle Should Be Minimum 300 Times. 11) It Should Have Iso & Conformity To Ce. , Fiber-Optic Video Bronchoscope(Brand - Karl Storz /Olympus ) Specification Fiber-Optic Video Bronchoscope Required With Video Illumination To Visualize And Document The Operational Area On Screen. It Should Consist Of Following Features: Monitorscreen 8 To 12 Inch In Size For Display With Touch Screen To Control Features With Hdmi Output For Connecting To A Big Screen Which Can Display Picture Simultaneously On Both Screens.Monitor Should Have Two Ports To Connect Two Video Endoscopes At One Time And Pictures Can Be Swapped Using Touch Screen. Monitor Should Be Chargeable, To Be Supplied With Charger And Should Have Facility To Be Used While Charging. Monitor Resolution Should Be Minimum 1920 X 1200 Pixels In 16:9 Format.Integrated Recording Of Video & Still Images Should Be Possible On Data Card Or Usb Drive With Jpeg And Mpeg Format Which Can Be Easily Transferred To The Computer/Laptop. Documented Videos & Still Images Should Be Easily Recalled On The Monitor. Monitor Should Have A Facility To Connect Flexible Scope Directly Without Any Special Coupler Or Accessory. Monitor Should Have Picture-In-Picture & Side-By-Side Mode To View Images From Flexible Video Scopes. Monitor Should Be Splash Proof According To Ip 54 And Should Be Shock Resistant.Monitor Should Have Lithium-Ion Rechargeable Batteries And Run For At Least 100 Mins. When Fully Charged. Soft Bag From Same Manufacturer Should Be Supplied To Place The Monitor And System Can Also Be Operated Without Taking Monitor Out From The Bag. Same Monitor Should Be Compatible With All The Below Mentioned Scopes Of Same Manufacturing Principal Company .Reusable Fiber Optic Video Bronchoscope.Single Use Flexible Intubation Video Endoscope A Fiber Optic Bronchoscope Is A Medical Device Used To Visualize The Airways During Bronchoscopy, A Procedure Where A Thin, Lighted Tube Is Inserted Into The Lungs To Examine Them. The Specifications Of A Fiber Optic Bronchoscope Typically Include Its Outer Diameter, Working Length, Field Of View, Angulation Capabilities, And The Diameter Of Its Working Channel. Key Specifications:Diameter: Bronchoscopes Come In Various Sizes, With Outer Diameters Ranging From 2.5 To 10 Mm. Smaller Diameters (E.G., 4.9 Mm) Are Suitable For Smaller Patients, While Larger Diameters May Offer Better Image Quality And Suction Capabilities. King Length: The Working Length, Which Is The Distance From The Distal End Of The Bronchoscope To The Insertion Point, Typically Ranges From 30 Cm To 60 Cm. View: This Refers To The Angle Of Vision That The Bronchoscope Offers. A Wider Field Of View (E.G., 110-120 Degrees) Allows For A Broader View Of The Airways. Angulation: The Ability To Bend The Tip Of The Bronchoscope Allows For Maneuvering Into Various Airways. Up And Down Angulation Capabilities Are Typically Around 180 Degrees And 130 Degrees Respectively King Channel Diameter: The Working Channel Is The Passage Through Which Instruments Like Forceps For Biopsies Or Suction Devices Can Be Passed. It Is Typically 1.2-2.3 Mm In Diameter Other Notable Specifications: 26/25 All Above Equipment Should Be From Same Manufacturers And Usfda & Ce Approved , Anaesthesia Workstation Complete With Anaesthesia Gas Delivery System, Vaporiser, Circle Absorber System With Built In Anaesthesia Ventilator & Withmultipara Monitor Brand - -Drager/Penlon/Bpl General • Should Have Provision For Delivery Of Oxygen, Nitrous Oxide And Medical Air • The Machine Should Be Capable Of Delivering Low Flow Anaesthesia. • The Anaesthesia Machine With Circle Absorber, Ventilator And Vaporiser Should Be From Same Manufactureranaesthesia Machine Should Be Ce Notified Body Approved. • Anaesthesia Machine Should Be Cdsco Approved. Vaporizer Should Be Us Fda Approved.Should Have Independent Attachments For Connecting Central Gas Supply And Pin Indexed Cylindershould Have Non-Interchangeable Pipeline Hose Inlet Connection To Pipelines For Medical Oxygen, Nitrous Oxide, And Medical Air Should Have Large Size Pressure Gauges, For Easy Visibility, Colour Coded, Two Each For Oxygen And Nitrous Oxide; One For Airanaesthesia Machine Frame Shall Be Manufactured In Strong But Lightweight Material.The Machine Shall Have A Maximum Of Four Castors/Wheels For Manoeuvrability With Front Two Castors Having Brakesshould Have Minimum Two Non-Lockable And Spacious Drawers For Storing Accessoriesthe Frame Shall Have Gcx Compatible Channels Incorporated For Mounting Other Accessories. • The Option For An Integrated Independent Oxygen Flow Meter For Oxygen Delivery Is Mandatory. Frame Shall Accommodate Up To Two Backup Cylinders One Each For Oxygen And Nitrous Oxideon Activation Of The System On/Off Switch Gas Flow And Vaporization Shall Immediately Be Availableshould Have Selector Switch For Selecting Open And Close Circuit Operation • The Common Gas Outlet Shall Be Mounted At The Front Of The Machine (Not Rear Or Side) To Be Easily Accessible In The Event Of An Emergency And For Use Of Alternate Breathing Circuits • The Option For Illumination Of The Writing Table/Work Surface Is Mandatory • The Frame Should Have Integrated Power Outlets To Supply A Minimum Of Three External Devices • Should Have Top Shelf, Manoeuvring Handle And Footrest • Machine Should Have Table Topwork Space To Keep Drugs. • The Unit Should Have A Battery Back-Up Facility For The Ventilator In The Event Of Power Loss. Minimum 90 Minutes Battery Backup Required. • Input Power :100 – 240 Vac Gas Flow • Antistatic And Cascaded Dual Flow Tubes Should Be Available For All Gases (O2, N2o& Air) To Allow Suitable Resolution And Accurate Control At Low Total Fresh Gas Flows. • The Flow Range Shall Be 150Ml-10 Lpm • Should Have N2o Cut Off Facility If O2 Supply Fails. • Should Have Oxygen Failure Alarm Both Visual And Audible. • Should Have Oxygen Flush Facility Bypassing Vaporiser. O2 Flush Switch Should Be Conveniently Placed For Easy Accessibility. O2 Flush Switch Should Be Non-Lockable. • The Unit Shall Have A Mechanical Anti-Hypoxic Device (Ahd) System To Control The Ratio Of Oxygen And Nitrous Oxide. A Completely Mechanical Ahd System, That Requires No Electricity, Is Mandatory • The Mechanical Ahd System Must Limit Minimum Oxygen Levels To Approximately 25% • Should Have Minimum Mandatory Oxygen Flow Of 100 Ml When Switched On • It Shall Be Possible To Deliver Air With Only Basal Flow Oxygen Independent Of The Abovementioned Hypoxic Control. • Gas Flow Shall Be Controlled Mechanically Only • Visual Display Of Individual Gas Flows Is Mandatory, This Shall Be By Physical Means Such As Glass Flowmeters Independent Ofelectrical Power • Flow Meters Should Have The Option Of Backlight Illumination • In The Event Of Complete Power Loss And Battery Failure It Shall Still Be Possible To Set The Fresh Gas Flow Accurately For Each Gas, Manually Ventilate (With Bag) And Continue To Keep The Patient Anaesthetized. • Anaesthesia Machine, Vaporizer And Ventilator Should Be From Same Oem. • Provide Isoflurane And Sevoflurane Vaporizer With Themachine. Vaporizers • The Unit Should Accommodate At Least Two Vaporizers For Anaesthetic Agent Delivery. • The Manifold Should Only Accept Vaporizers With Approved Back Bar Connections And Prevent Usage Of More Than One Vaporizer Simultaneously. Preferably Selectatec Compatible Back Bar. • Vaporizers Supplied With The Unit Shall Be Routine Maintenance Free For The Life Of The Product • Vaporizers Supplied With The Unit Shall Be Manufactured From Lightweight Materials To Aid In Fitting & Removal • Should Have An Operating Flow Range Of0.2 – 15 L/Min And Nominal Capacity 250 Ml Ventilator • Ventilator Shall Cater For A Diverse Range Of Patient Groups From Neonates To Adult Patients With Restrictive Airways • Ventilator Should Be Pneumatically Driven And Controlled Electronically • Ventilator Shall Have A Large 8.4” Colourtft Display, For Exclusive Use Of Ventilator Control And Monitoring. • Control Ofthe Ventilator User Interface Shall Be By Touch Screen And Rotary Dialventilator Shall Have The Following Ventilation Abilities, Volume Control (Vcv), Pressure Control Ventilation (Pcv), Simv-V And Simv-P ,Spont/Pressure Support Ventilation (Psv),Manuaassisted Modes Of Breathing Shall Be Flow Triggered. Ventilator Shall Compensate For Fresh Gas Flow And Compliance Of The Entire Circuit. Should Have User Adjustable Alarms For Major Parameters Such As Tidal Volume, Minute Volume,Fio2,Airway Pressure, Frequency Apnea Alarms Must Be User Adjustableto Allow For All Operating Conditions And Phases During Anaesthesia Ventilator Should Have The Ability To Display Patient Spirometry Loop Ventilator Should Also Display Waveforms For Flow, Volume And Airway Pressure Stem Absorber & Not Remoted Via Tubes Or Channelsvolume Measurement Sensors Should Not Be Disposable Typeventilator Parameterstidal Volume- 10Ml-1600 Mlfrequency- 4-100 Bpm I:E Ratio- 4:1 To 1:10 Inspiratory Pause - 0-60% Of Ti Peep - Off, 3-30 Cmh2o Pressure Limit - 5-70 Cmh2o Minute Volume-0.5 To 60 Lpm Breathing System • The Breathing System Designed So That It Can Be Removed & Replaced As A Complete Unit Without The Use Of Tools • All Parts Of The Breathing System That Are In Contact With Patient Gas Shall Be Latex Free And Autoclavable Except For Non Autoclavableremovable Part Like O2 Sensor And Pressure Manometer. • Bag/Vent Switch Shall Be Integrated On The Absorber And Should Activate Ventilator In Vent Mode And Vice Versa (One Step Operation). • Breathing System Should Have Heater System To Avoid Water Condensation. • Should Have Quick Release Canister For Sodalime , Capacity Minimum 1.5 Litre • The Breathing System Absorber Canisters Shall Have A Bypass System To Allow For Canister Change Mid-Case Without Loss Of Ventilation Pressure. The Requirement For An Automatic Bypass Without Extra Input From The User Is Mandatory • The Ventilator Bellows Shall Be Clearly Visible And Be Of Upright Design.The Bellows Should Ascend On Expiration To Provide A Quick Visual Indicator For Assisted Breathing, Spontaneous Breathing And System Leaks. • Same Bellows Shall Be Used For Adult And Pediatric Application • Should Have Provision For Fio2 Monitoring Cell And Fio2 Value Should Be Monitored On The Main Screen. • A Bag Arm With Positional Adjustment Shalmulti Parameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,( Massimo),Nibp (Suntech) Temperature,Dual Ibp, Agm ( Massimo) Mainstream. 3. Should Have 12-Inch Color Lcd Display. 4. Should Have Dual Modes Of Operation: Rotary Knob. 5. Should Display 7 Waveforms Or More 6. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen. 7. Ecg: ? Should Be Able To Monitor Ecg Through 5-Lead Patient Cable ? Should Have Manual St Analysis Window ? Should Detect 20 Arrhythmias And Generate Alarms. ? The Priority Of Arrhythmia Alarms Can Be Configurable ? Should Measure Pvc & Pac ? Should Be Able To Monitor Heart Rate From 10-300 Bpm ? Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etc ? Should Have Pacemaker Detection Facility 8. Respiration: ? Measurement Range Of 0 To 150 Breaths Per Min ? Should Have Gain Selection: ×0.25, ×1, ×2, ×4 ? Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S ? Should Have Apnea Detection Facility ? Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 9. Spo2: ? Should Have Massimo Technology ? Should Have Measurement Range Of 0~100 % ? Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph ? Should Be Able To Select Sat Sec To Avoid False Alarm 10. Nibp: ? Must Be Of Suntech Medical Technology For Clinical-Grade Blood Pressure Measurement ? Should Have Auto, Manual, And Stat Modes Of Operation For Nibp. ? Should Have A Measuring Range Of 0-280 Mmhg 11. Should Have 2 Channels For Temperature Monitoring 12. Should Have Data Storage Capabilities: O 72 Hours Of Trend Data Storage. O 2000 Sets Of Nibp Measurement Data. O 200 Alarm Events O Physiological Alarms Can Be Reviewed With 16 Sec Of Associated Waveform Along With Other Parameter Values. Even Print Out These Waveforms With Optional Recorder O 7 Leads Of Ecg Waveform Disclosure At Least Of 1-Hour O Should Have Facility To Transfer The Trend Data To Usb 13. The Monitor Should Have Drug Dose Calculator And Oxy-Crg View Screens 14. Snapshot Facility With Usb Transfer. 16.Should Have Alarm Settings For All Parameters. 17.Should Have Color Coded Alarms And Alarms Priority Can Be Configurable. 18. Should Have Cns Connectivity Of Same Make. 19.Monitor Should Be Able To Directly Connect With Hospital Information System (His 20.Should Have Standby And Night Mode 21.Should Have Li-Ion Battery 22.Battery Should Have 3.5 Hrs Of Operation 23.Monitor Should Be Ce Certified 24.Manufacturer Should Be Iso Certified 13485:2016 , Bi-Phasic Defibrillator Brand - Bpl/Maestros Technical Specifications For Bi-Phasic Defibrillator • The Machine Should Have Facility For Ecg Monitoring, Bi-Phasic Defibrillation,With Facility To Print Ecg Through In-Built Thermal Printer,• Should Be Extremely Light-Weight (Less Than 10 Kgs) • Should Have Monitoring Facility Through Color Tft Display With Screen Size At Least 7” Or Better. • Should Have Both Synchronous And Asynchronous Mode. • The Defibrillator Should Be Biphasic Technology Based Having Energy Selection Of 2-300 Joules• It Must Be Capable Of Monitoring Ecg Through Ecg Cables, Multi-Function Electrodes And External Paddles. • The Machine Should Be Able To Defibrillate Adult, Paediatric Patients. • The Machine Should Have Ecg Wave Form Display On Bright Screen Along With Other Vital Numeric Information. • Should Be Able To Monitor Ecg• Should Have Facility For Auto Testing When Switched On And During Operations. • The Machine Should Be Compact, Portable With Built In Rechargeable Battery. • Should Have External Pacemaker With Fixed Or Demand Mode. • Should Be Able To Deliver A Maximum Of 300J In Aed Mode • Should Have A Minimum 2 Hours Battery Capacity For Monitoring And 1 Hour Battery Capacity For Giving Minimum Of 100 Shocks.• Energy Selectiononfront Panel Button And External Paddle Buttons • Charge Control On Front Panel Button And External Paddle Buttons • Charge Indicator Charging Tone, End Of Charge Tone, Led In Charge• Shock Control Buttons On The External Paddles • Should Have External Defibrillator Adult And Paediatric Paddles.• Charging Time - Less Than 8 Seconds At 300 J With A New And Fully Charged Battery • The Machine Should Have User Selectable Alarm Settings• The Machine Should Store At Least 24 Events For Viewing Or Recording.Ecg: • Should Be Able To Monitor Ecg Through 5-Lead Patient Cable • Should Be Able To Display Lead I,Ii,Iii, Avr, Avl, Avf And One Of The Chest Leads• Should Be Able To Monitor Heart Rate From 15-300 Bpmgeneral Specifications• The Machine Should Work On Mains As Well As Rechargeable Battery. • The Device Should Be Manufactured From An Iso Certified Organization• Machine Should Be Supplied With Standard Accessories• System Should Be Easy To Operate With Facility To Give Print Command, Charge And Energy Selection On Both External Paddles And On The Main Unit.• Should Have Upgradable Facility For Masimo Etco2.• Should Have Upgradable Facility For Spo2.• Should Have Upgradable Facility For Nibp.• Should Have Upgradable Facility For Pacer Also. , Multi Para Monitor With P, Nibp, Ecg Facility (Brand - Bpl/Maestros/Drager)) Technical Specifications For Multipara Monitor 1. Multi Parameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,( Oxyset+), Nibp (Suntech) Temperature. 3. Optional Parameter Etco2, Dual Ibp, Agm 4. Should Have 12-Inch Color Lcd Display. 5. Should Have Dual Modes Of Operation: Rotary Knob. 6. Should Display 7 Waveforms Or More 7. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen. 8. Ecg: ? Should Be Able To Monitor Ecg Through 5-Lead Patient Cable ? Should Have Manual St Analysis Window ? Should Detect 20 Arrhythmias And Generate Alarms. ? The Priority Of Arrhythmia Alarms Can Be Configurable ? Should Measure Pvc & Pac ? Should Be Able To Monitor Heart Rate From 10-300 Bpm ? Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etc ? Should Have Pacemaker Detection Facility 9. Respiration: ? Measurement Range Of 0 To 150 Breaths Per Min ? Should Have Gain Selection: ×0.25, ×1, ×2, ×4 ? Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S ? Should Have Apnea Detection Facility ? Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 10. Spo2: ? Should Have Nellcor Technology ? Should Have Measurement Range Of 0~100 % ? Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph ? Should Be Able To Select Sat Sec To Avoid False Alarm 11. Nibp: ? Must Be Of Suntech Medical Technology For Clinical-Grade Blood Pressure Measurement ? Should Have Auto, Manual, And Stat Modes Of Operation For Nibp. ? Should Have A Measuring Range Of 0-280 Mmhg 12. Should Have 2 Channels For Temperature Monitoring 13. Should Have Data Storage Capabilities: O 72 Hours Of Trend Data Storage. 2000 Sets Of Nibp Measurement Data. O 200 Alarm Events O Physiological Alarms Can Be Reviewed With 16 Sec Of Associated Waveform Along With Other Parameter Values. Even Print Out These Waveforms With Optional Recorder O 7 Leads Of Ecg Waveform Disclosure At Least Of 1-Hour O Should Have Facility To Transfer The Trend Data To Usb 14. The Monitor Should Have Drug Dose Calculator And Oxy-Crg View Screens 15. Snapshot Facility With Usb Transfer. 16.Should Have Alarm Settings For All Parameters. 17.Should Have Color Coded Alarms And Alarms Priority Can Be Configurable. 18. Should Have Cns Connectivity Of Same Make. , Fully Functional Automatic Dental Chair With Inbuilt Suction And Compressor (Brand- Confident / Chamundi) Programmable Dental Chair, Unit Fitted With Floor Mount Light With Led(Faro, Maia) Operating Light Having, On/Off And Intensity Control By Non-Touchsensor Monitor Mounting Arm High And Low Vacum Motorized Crs Suction System Autocalvable 2 Nos Beecool Ii Light Cure Cordless-1 No Modular Trolley System Over The Patient Airotor Points- 2 Nos Supreme Micromotor 35,000Rpm With Digital Display Of Speed Three Way Syringe- 1 Nos Supreme Optic Scaler With Five Scaling Tips With Endo Chuck 1 No Ss Instrument Tray X-Ray Viewer Multi Function Foot Control Comfort Dental Operators Stool Compressor Monobloc Oil-Free Medical Grade Airotor Air Compressor 1.5/2 Hp With Radiator Cooler, Condensor, Silicon Column Filter For Moisture, Dust Filter Microbial Filter Fitted On Ms Tank. , Dental Aerotor(Brand - Nsk) Push Button With Led Light , Dental Micromotor Contrangle(Brand - Nsk) Latch Type , Dental Micromotor Straight With Led Light (Brand - Nsk) , Round, Straight Surgical Bur For Straight Hand Piece Micromotor Carbide Burs(Brand - Nsk/Prima) , Round, Straight, Inverted Cone And Tapered Fissure Burs For Aerotor Diamond Fg (Brand- Dent Ark) , Rotary Files Niti Files Sx, S1 S2 F1 F2 And F3 (Brand- Dent Ark /Nsk) , Ultraound Color Doppler System (Brand -Samsung Hs30/ Ge Logiq / Mindray Mx7 (3D,4D)/Bpl) Technicalspecification 1. The Units Should Be Latest State Of The Art Digital Color Doppler With Broadband Beam Forming For Cardiac, Abdominal,Vascular And Ob/Gynapplication. The Models With Following (Or Higher) Specifications Need To Be Quoted. 2. The Machines Should Be Usa Fda And European Ce Certified And Should Be Latest In Technology And Launched In 2016 Or Later. The Manufacturing Company Should Be Iso Certified. 3. They Should Have At Least 750000 Digital Processing Channels For High –Resolution Imaging. 4. Imaging Modes : 2D, M- Mode, Color Flow Imaging, Pulse Doppler, Power Doppler, Continuous Wave Doppler And Directional Color Flow Mapping, 3D/4D Imaging Modes 5. The Machine Should Be Supplied With Dedicated 3D/4D Package 6. The Machines Should Have Facility For Simultaneous Dual/ Duplex/ Triplex Mode Display 7. Tissue Harmonic Imaging Should Be Available On All The Transducers. 9. Machines Should Be Capable Of Advanced Real Time Compound Imaging. 10. Should Have Frame Rate 1500 Fps Or More 11. Scanning Depth Should Be 40 Cms Or More 12. High Dynamic Range Of 250 Db Or More. 13. The Machines Should Have 256 Grey Shades (8 Bit) Or More. 14. One Touch Image Optimization Should Be Available In 2D Mode With One Button Automatic Adjustment Of Tgc And Receiver Gain And Compression Curve Based On The Range Of Detectable Tissue Signals. 15. There Should Be One Button Automatic Adjustment Of Doppler Prf, Baseline, Dynamic Range And Gain In Doppler Mode. 16. Pulsed Wave Doppler Should Be Available On All Imaging Transducers With Adjustable Sample Volume Size, Simultaneous Or Duplex Mode Of Operation, Simultaneous, 2D, Colour Doppler, Pulsed Doppler, High Prf Capability In All Modes Including Duplex And Triplex And Automatic Adjustment Of Scale And Baseline. The System Should Have Option To Adjust The Color Flow Mode For High Or Low Flows In One Touch. 17. Machines Should Support Broad Band/ Wide Band High Density Probes Spanning With Frequency Range From 1-20 Mhz (+/- 1 Mhz). The System Should Support Latest Technology Single Crystal Probe Or Matrix Array Probes For Better Resolution And Penetration. 18. Automatic Doppler Analysis Should Be Available With Automatic Real Time Calculation Of At Least Sixof Following User Selectable Parameters Peak Systolic Velocity End Diastolic Velocity, Mean Diastolic Velocity, Volume Flow, Time Average Mean Velocity, Time Average Peak Velocity, Resistive Index, Pulsatility Index, Systolic/ Diastolic Ratio, Acceleration/ Deceleration Times. 19. The Machine Should Have Up To 500000 Images Storing Facility And Cine Loop Review Facility With Memory Up To Minimum Of 25,000 Frames 20. The Machines Should Have Facility Of Direct Storage And Retrieval Of B/W And Color Images (Both Frozen And Cine Loop) In The Inbuilt Hard Disk Drive. In Built Hard Disk Storage Should Be Equal To Or More Than 1Tband Solid State Device In Addition With Capacity 120Gb. 21. The Machines Should Support Four Or More Transducers With Universal Ports Allowing Any Transducer To Be Connected To Any Port. 22. Machines Should Have A High Resolution Fully Articulating Non-Interlaced Flicker Free, Anti-Glare Led Display Of 21 Inches Or More With Resolution 1,920X 1,080 Or Better.In Addition, The Machine Should Have 10” Or More Touch Control Panel For Easy Access. 23. The System Should Have Image Enhancement Options Like Speckle Reduction, Spatial Compounding And Filtered Tissue Harmonics. The System Should Have Adaptive Blending Color To Maintain The 2D Resolution While Working In Color Mode. 24. Zoom Facility (Upto 8 Times Or More Magnification) With High Resolution Results And Pan Capacity In Both Real Time And Frozen Images. 25. The System Should Have Cd-Dvd And Usb Archival (Dicom And Pc Format).There Should Be 4 Or More Usb Ports. 26. Machine Should Be Offered With The Following Broadband Probes (I) Cardiac Package Along With Adult Phased Array Transducer With Frequency Ranging 1.0 - 5.0Mhz (+/- 1.0Mhz). (Ii) Convex Transducer Frequency Ranging ( C1-6Ct) Mhz. (Iii) Liner Transducer Frequency Ranging (L3-12T ) Mhz (Iv) Tvs Transducer Frequency Ranging (Ec3-10T) 27. Online 1Kva Upsand Color Inkjet Printer 28. Preference Would Be Given To Products Manufactured In India, Japan, Korea, Europe, Us. , Laproscopic Surgery Set With Hysteroscope And Resectoscope (Brand Ethicon/ Mindray Medical Pvt Ltd/ Karl Storz/ Conmed/Olympus) Unit And Camera Head The System Should Have The Full Hd Resolution-1920 X1080 Internal Medical Grade Recorder For Capturing Full Hd Videos And Full Hd Stills With Storage Capability Internal Of 50 Gb Or External Medical Grade Recorder Should Be Provided From The Same Manufacturer. System Should Have The Facility Of Controlling The Recording Device From The Camera Head. Video Scopes Can Be Connected To The Same. The Camera System Should Be Able To Provide With 1080 P Lines For Hd Resolution Image. Technical Specifications: Image Sensor: 1 Xcmos Agc: Microprocessor Controller Weight: 130Gm Focal Length: 16Mm Control Buttons: 3 (2 Of Them Freely Programmable) Input: Keyboard Input For Character Generator. Power Supply:-100-240 Vac 50/60 Hz Certified To: Iec 601-1, 601-2-18, Csa 22.2 No. 601, Ul 2601 And Ce According To Mdd, Protection Class1/Cf 2 High-Definition Medical Grade Monitor Led Crystal Display. Max. Resolution Of 1920X1080. Screen Diagonal - 27Inches Desk Top With Pedestal. Should Have The Facility Of Pip Mode. Accessories External 24Vdc Power Supply, Mains Cord, Pedestal. Certified To: En 60601-1, Protection Class Ipx 1 Led Light Source With Fiber Optic Cable Color Temperatures 6400K External Light Source Light Outlets - 1 Light Intensity Adjustment: - Continuously Adjustable Manually From Light So Should Be Supplied With Light Cable, Diameter 4.8Mm, Length 250Cm. Certified To :- Iec 601-1 & Ul 544 Ce According To Mdd, Protection Class 1/C Telescopes Forward Oblique 30 Degree Telescope, Diameter 10 Mm, Autoclavable, Length Optic Light Transmission Incorporated. Forward Oblique 30 Degree Telescope, Diameter 5 Mm, Autoclavable, Length 2 Optic Light Transmission Incorporated Co2 Insufflator Technical Specifications: Gas Flow: 0-400 L/Min Cv 625 Laprascopy Set Pressure: 0-30 Mmhg (4000Pa). High Flow Mode (0 To 40 L/Min.) Sensitive Mode Pressure 15 Mm Hg & Flow 15 L/Min For Sensitive Application Electronic Control And Colour Touch Screen, Following Data Are Displayed On Touch Screen: -Insufflation Mode. Set Value Pressure (0-30 Mmhg). Current Patient Pressure. Set Value Gas Flow (0-40 L/Min). Current Gas Flow. Gas Consumption (0-999 1). Reusable Insufflation Tube For Co2 Gas Up To Patient Body. High Flow Mode With Flow Performance Up To 40 L/Min. Easy And Intuitive Use With User Friendly Color Touch Screen 7 Inch For Easy And Precise Setting Of Set Values For Pressure And Flow And Of Insufflation Mode, As Well As For Clear Display Of Corresponding Set Values And Actual Values. Optical And Acoustic Alarm Signals In The Event Of Patient Overpressure Should Have Hose Pipe. Equipment Cart From The Same Manufacture Should Be Quoted With 4 Or More Helves Isolation Transformer Co2 Cylinder Holder Laparoscopic Instruments- Detailed Description • Veress Pneumoperitoneum Needle With Spring Blunt Stylet, Luer-Lock, Length 13 Cm & 15 Cm –2 Nos • Trocar, Size 11 Mm, Color Code: Green, Consisting Of: Trocar Only, With Pyramidal Tip Cannula Without Valve, With Insufflation Stop-Cock, Length 10.5 Cm Multifunctional Valve, Three Part Dismantel, With Washers Pack Of 10 – 4 Nos • Trocar, Size 6 Mm, Consisting Of: Trocar Only, With Pyramidal Tip Cannula Without Valve, With Insufflation Stop-Cock, Length 10.5 Cm Multifunctional Valve, Three Part Dismantel With Washers Pack Of 10 – 4 Nos • Reduction Sleeve, 11/5 Mm – 1 Nos • Reducer 11/5 Mm– 1 Nos • Telescope, Diameter 10 Mm, Length 32 Cm, Autoclavable, Variable Direction Of View From 0°-90, Adjustment Knob For Selecting The Desired Direction Of View, Fiber Optic Light Transmission Incorporated- 1 Nos •Injection Needle, Luer-Lock, Diameter 1. 2 Mm, Size 5 Mm, Length 36 Cm - 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 3 6 Cm, Right Angled, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Insert, And Outer Tube, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Long, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting- And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Alligator Jaws, Double Action Jaws, Consisting Of: Plastic Handle Without Ratchet, With Larger Contacact Area, Insert And Outer Tube, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Siz E 5 Mm, Length 36 Cm, With Connector Pin For Unipolar Coagulation, Atraumatic, Jaws With Multiple Teeth, Fenestrated, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Atraumatic, Jaws With Multiple Teeth, Fenestrated, Long, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, 2 X 4 Teeth, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle With Manhes Style With Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Bowel Grasper, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area Outer Tube, Insulated., Three Parts Dismantle 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Cleaning, Single Action Jaws, Atraumatic, Fenestrated, Curved, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet Metal Outer Sheath, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Atraumatic, Fenestrated, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Insert And Outer Tube, Three Part Dismantel. 1 Nos • Three Plece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Heavy, Double Action Jaws, Consisting Of: Plastic Handle, With Manhes Style Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel – 1 Nos • Three Plece Scissor, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Deaning, Double Action Jaws, Curved, Length Of Blades 15 Mm, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Insulated, Without Ratchet Metal Outer Sheath, Insulated Scissors Insert For Use With Trocars Size 6 Mm Three Part Dismantel 1 Nos • Single Use Scissor Insert Pack Of 10 (1X10) 1 Nos • Three Piece Laparoscopic Hook Scissors, Rotating, Size 5 Mm, Length 36 Cm, Jaws Not Crossing With Connector Pin For Unipolar Coagulati On, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Outer Tube, Insert, Three Parts Dismantel 1 Nos • Three Plece Laparoscopic Autoclavable Grasping And Dissecting Forceps, Single Action Jaws, Fenestrated, 360 Degree Rotational Sheath, Size 5 Mm, Length 36 Cm, Long, Ergonomic Metal Handle With Plastic Finger Rings With Larger Contact Area At The Finger Ring To Avoid Pressure Sores, Can Be Dismantled With The Press Of A Button. 1 Nos • Suction And Irrigation Tube, Anti-Reflex Surface With Two-Way Stopcock, For Single Hand Control, Size 5 Mm, Length 36 Cm 1 Nos • Olsen Suction Or Irrigation Tube, With Protection Basket, With Trumpet Valve, Size 10Mm Length 36Cm. 1 Nos • Dissecting-Electrode, L-Shaped, Size 5 Mm, Length 36 Cm, With Connector Pin For Unipolar Coagulation, Consisting Of: Outer Tube, Insulated Plastic Handle Electrode L-Shaped With Trumpet Handle 1 Nos • Coagulating And Dissecting Electrode, L-Shaped, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Working Length 36 Cm 1 Nos • Coagulating And Dissecting Electrode, Spatula-Sheaped, Blunt With Connector Pin For Unipolar Coagulation, Size 5 Mm, Working Length 36 Cm 1 Nos • Macro Needle Holder, Ergonomic Axial Handle With Disengage Able Ratchet, Ratchet Release On The Right Side, Left Curved Jaws, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm 1 Nos • Macro Needle Holder, Ergonomic Pistol Handle With Disengage Able Ratchet, Ratchet Release On The Right Side, Right Curved Jaws, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm 1 Nos • Dismantling Needle Holder, Ergonomic Pistol Grip With Disengage Able Ratchet, Ratchet Release On The Left Side, Jaws Curved Left, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm Consisting Of: Insert, Outer Tube, Handle 1 Nos • Unipolar Hf Cord With 4Mm Banana Plug And Length 300 Cm 1 Nos • Clip Applicator, For Use With Ethicon Titanium-Clips Lt-300 (Medium Large), Dismantling, Rotating, With Ratchet To Lock The Jaw Part Holding The Clip, Size 10 Mm, Length 36 Cm, Consisting Of: Metal Handle, With Ratchet Metal Outer Tube Insert, Three Part Dismantel, 1 Nos • Claw Forceps, Rotating, Size 10 Mm, Length 36 Cm, 2 X 3 Teeth, Single Action Jaws, Consisting Of: Metal Handle, With Manhes Style Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Claw Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, 2 X 3 Teeth, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area Outer Tube 1 Nos • Rotatable Bipolar Grasping Forceps, Rotating, Dismantling, With Connector Pin For Bipolar Coagulation, Double Action Jaws, Especially Suitable For Dissection, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet, Color Code: Light Blue Outer Sheath Forceps Insert, Three Part Dismantel. – 1Nos • Rotatable Bipolar Grasping Forceps, Rotating, Dismantling, With Connector Pin For Bipolar Coagulation, Double Action Jaws, Fine Atraumatic Serration, Fenestrated, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet, Color Code: Light Blue Outer Sheath Forceps Insert, Three Part Dismantel. – 1 Nos • Bipolar Hf Connecting Cable Length 300 Cm, Compatible With All Standard Cauteries – 1 Nos • Fascial Closure Instrument For Sub Cutaneous Ligature Of Trocar Incisions – 1 Nos • Myoma Fixation Instrument, Screw Shaped, 5 Mm. – 1Nos • Dismantling Fan Retractor, Distendable, Size 5 Mm, Length 36 Cm.- 1 Nos • High Frequency Needle, For Splitting And Coagulation, Insulated, Retractable, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 31 Cm. 1 Nos • Single Use Scissor Insert Pack Of 10 (1X10) - 1 Nos • Uterine Manipulator: Uterine Manipulator For Providing Tissue Tension Needed For Anatomical Surgery. The Manipulator Should Have Application In Tlh, Lash, Lavh And Hysterectomies For Malignant Pathologies 1 Nos • Sterilization Tray For 2 Telescopes (Same Manufacturer) • Sterilization Tray For Instruments (Same Manufacturer) Hysteroscopy Set Hysteroscope Sheath For Diagonostic Continuous Irrigation Size 6.1-6.3Mm Outer Sheath And 5.1-5.3 Mm Inner Sheath For Use With 4Mm Hysteroscope Telescope. Hysteroscope Sheath For Operative Continuous Irrigation Size 5.9-6.1Mm Outer Sheath With Operating Channel 5Fr, Leur Lock Adaptor And 5.3-5.5Mm Inner Sheath For Use With 4Mm Hysteroscope Telescope. With Stopcock & Leur Lock Adaptor And Inflow And Outflow Channe Semi Rigid Instruments For Use With Operating Hysteroscope Scissors Semi Rigid, Blunt Tips, 5 Fr., Length 36-40Cm, Single Action Jaws Scissors Semi Rigid, Pointed Jaws, 5 Fr., Length 36-40Cm, Single Action Jaws, Semi-Rigid Biopsy- And Grasping Forceps Semi Rigid, 5 Fr., Length 36-40Cm, Double Action Jaws Tenaculam Grasping Forceps Semi Rigid, 5 Fr., Length 36-40Cm, Double Action Jaws Bipolar Vaporization Electrode, Semirigid, 5 Fr., Needle Electrode Angled 90°, Length 42Cm Bipolar High Frequency, Should Fit In Most Of The Standard Electrosurgical Unit Having Bana Plug One Side, Length Should Be Not Less Than 250Cm Telescope 12, Enlarged View, Diameter 4 Mm, Length 30 Cm, Autoclavable, Fiber Optic Light Transmission Incorporated Bipolar Working Element To Be Used With 26 Fr Resectoscope Sheath: Motion By Means Of A Spring. The Thumb Support Is Movable. Return Of The Loop Is Control By The Thumb And In Rest Position The Electrode Should Rest Inside The Operating Sheath, To Be Used With 4Mm Hysteroscopy Telescope. Should Work In Saline Bipolar Cutting Loop 24 Fr Should Work In Saline Cutting Electrode 24Fr, Bipolar, Pointed, Should Work In Saline Coagulating Electrode 24Fr, Bipolar, Ball End Should Work In Saline Continuous Flow Resectoscope Sheath 26 Fr., For Bi-Polar, Including Connection Tubes For And Outflow, 2 Luer-Lock Adaptors, 26Fr, Oblique Beak, Rotating Inner Tube, With Ceramic Insulation, For Use With Working Element. Should Work In Saline Obturator, For Use With The Resectoscope Sheath. Fluid Management System (Irrigation & Suction Unit) Pressure Regulated Suction And Irrigation System For Use In Laparoscopy And Gynaecology Unit Should Have Touch Screen As User Interface. Unit Should Have Feature Of Automatically Fixing Maximum Parameters For Laparoscopy And Hysteroscopy Mode By The Choice Of Tubing Unit Should Have Feature Of Simultaneous Display Of Set Values And Actual Values Enabling User For Continuous Monitoring Of Suction And Irrigation Parameters Unit Should Have Feature Of Use Of Disposable/Reusable Cassette Tubing Set For Laparoscopy/Hysteroscopy Procedures. Unit Should Be Supplied With Glass Suction Bottle 5 Lite Unit Should Have Pressure Settings: Hysteroscopy Mode: 0-200 Mmhg Laparoscopy Mode: 100/300/500 Mmhg Unit Should Have Flow Settings: Hysteroscopy Mode: 200/400/600 Ml/Min Laparoscopy Mode: 0-1300Ml/Min Suction Pressure Regulated: Hysteroscopy Mode: 0.1-(-)0.8Bar (-80Kpa) Laparoscopy Mode: 0.1-(-)0.8Bar(-80Kpa) Power Supply: 100-240Vac, 50/60Hz Certified To: Iec 601-1, Ce Nach Mdd Certified To: Iec 601-1, Ce Acc. To Mdd Note: - All The Above Items Should Be Usfda And European Ce Certified And From Same Manufacturer For Better Compatibility And Maintenance , Integrated Electrosurgical Unit And Vessel Sealer Brand -Ensurge/ Hti Digital / Kls Martin / Enertech/Shalya Specifications For Integrated Electrosurgical Unit And Vessel Sealer 1) Advanced Electro Surgical Unit With Vessel Sealing System Have Mono Polar Cut & Coagulation, Bipolar And Vessel Sealing Technology, All Integrated In Single System 2) Type Of Display Should Be Lcd Touch Screen 3) Display Size Should Be 5” Or More 4) Unit Should Have Microprocessor-Controlled Tissue Feedback Technology. 5) The System Should Have Capability To Convert Electrical Energy To Radio Frequency Energy Thus Providing Radio-Frequency Seal 6) Number Of Tissues Sensed Per Sec Should Be 4000 Or Higher 7) Vessel Fusion System Must Be Able To Seal Artery, Veins Along With Tissue Bundle Up To & Including 7Mm In Diameter & Sealed Vessels Should Be Able To Withstand At Least 3 Times The Systolic Blood Pressure. 8) Low Frequency Leakage Should Be 50 Or Higher (In Ma) 9) High Frequency Leakage (Rf) Must Be Less Than 100Ma In Mono Polar And Vessel Sealing Mode And Less Than 70Ma In Bipolar Mode 10) Should Be Provided With Rs 232 Data Input Port For Software Upgrade Facility 11) System Must Have Recall Facility To Recall The Last Setting Used By User Before Turning Off The Power Directly Or Through User Programs. User Can Use Pen Drive With Their Setting To Recall The Setting Saved By Them. 12) System Should Have Bipolar Resection Including Under Water Cutting. 13) The System Should Be Provided With Twin Monopolar Socket (Only One Socket To Be Activated At A Time) With Independent Power Setting 14) 5 Or More Numbers Of Cutting Modes Available In Monopolar 15) Maximum Power Should Be 400W Or Higher 16) Maximum Power Of Blend Mode For Cutting With Homeostasis Should Be Not Less Than 250W 17) Fulgurate/Forced Mode, Spray Mode, Soft Mode Of Monopolar Coagulation Should Be Available. 18) Unit Should Be Supplied With 4 Or More Nos. Of Monopolar Coagulation Modes 19) Coagulation Mode Power (Monopolar) Should Be 150W Or Higher 20) Coagulation Mode Power (Bipolar) Should Be 120W Or Higher 21) Number Of Bipolar Cutting Modes Should Be Or Greater Than 5 22) Maximum Power For Ligation Not Less Than 100W 23) Maximum Power For Resection Not More Than 300W 24) Equipment Should Have On Screen Review Of Error Codes And Diagnostics. 25) System Should Have Patient Plate Contact Quality Monitoring System Giving Audio-Visual Alarm And Deactivating Output If Contact Between Patient And Patient Plate Is Not Proper To Eliminate The Risk Of Patient Burns. It Should Be Mandatory, Should Have Contact Quality Monitoring With Split Style Patient Return Electrode And Deactivates Output If Contact Between Patient And Patient Return Electrode Is Not Proper To Eliminate The Risk Of Patient Burns, Manufacturing By Same Oem 26) Auto Bipolar Start And Stop Along With User Configurable Auto Start Facility Should Be Available 27) Power Output Of Vessel Sealing System (Vss) Not More Than 150W 28) Vessel Sealing System Should Be Able To Seal Vessels Or Tissue Bundles Faster Than Any Conventional Devices (Preferably Within 2-4 Seconds) 29) Product Should Be Ce Certified (4 Digit Notified Body). 30) It Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification & Iso 9001: 2008 & Iso 13485:2003 Certified Company. 31) Warranty Of The Unit Should Be 5 Years 32) It Should Be Supplied With All Following Accessories, Should Be Reusable And Autoclavable: - O Patient Return Electrode --- 1 No. O Cable For Return Electrode --- 1No. O Hand Switching Pencil --- 1 No. O Foot Switching Pencil --- 1 No. O Double Pedal Footswitch With Toggle Function (Common/Individual For Monopolar, Bipolar And Vessel Sealing) - 3 No. O Universal Adaptor --- 1 No. O Bipolar Forceps --- 1 No. O Cable For Bipolar Forceps --- 1 Nos. O Set Of Electrode (Angled, Ball And Needle) ------ 1No. O Reusable Sealing Clamp With Cable--- 1 No. O Curved Jaw Vessel Sealer 5 Mm, 32 To 37 Cm -- 1 No. O Autoclavable Reusable Cutting Instrument – 1 No. Additional Terms & Conditions: 1. Vessel Sealing Laparoscopy Instruments Should Have Both Hand And Foot Activation Mode And Should Be Eu Ce (4 Digit Notified Body Certified) Or Usfda Approved. 2. All Sockets Should Be Of Blinking Light Type When In Use To Identify The Used Mode. 3. R.F. Frequency Should Be In Between 350-500Khz For All Modes. 4. It Should Have Bipolar Rf Scalpel Mode For Dissection & Desiccation. Rf Bipolar Scalpel Instruments Should Have Hand Control Button For Coagulation & Cut. 5. Equipment Should Be Usfda Approved/ Eu Ce (4 Digit Notified Body Certified). It Should Have Iec-60601-1- 1, Iec 60601-2-2 Safety And Des , Ctg Machine Brand - Bpl/Maestros/Bistos Specification Foetal Monitor With Display And Printer Should Have 12.1” High Resolution Colour Tft Display With Tiltable Screen For Better Viewing. Should Display Fhr, Toco, Foetal Movementin Numeric Values . Should Display 2 X Fhr And Toco Graphs In Different Colours. Should Have The Facility For Data Save With Play Back & Print Facility Should Have Facility To Monitor Information Of Last 25 Hours Should Have Special High Sensitive Watertight Probe For Better Durability Should Have The Low Ultrasound Power For The Safety Of The Foetus Should Have Automatic Foetal Movement Detection Should Have Event Marking Facility By Mother And User Thermal Printer With Minimum 152Mm Paper Width Is Essential For Broader Printouts Standard Configuration Should Be Fhr, Toco, And Foetal Movement Should Have Volume Control For Fhr Beep Sound And Alarm. Should Have Alarm Setting For Weight Should Be Less Than 4 Kg For Easy Portability. Should Have Foetal Stimulator Built In To Fhr Probe And Activation Key Should Be There On The Front Panel. Stimulation Should Be Recorded On The Recording Paper And Should Be Displayed On The Screen. Built In Rechargeable Li-On Battery For Backup Should Work With Input 200 To 240Vac 50 Hzsupply Central Monitoring System Software Upgradability Should Be Possible (Optional) Should Be Supplied With The Following Standard Accessories: Power Cord- 01 Fhr Probes – 01 Nos Toco Probe -01 Patient Event Marker Belts – 02 Nos Gel – 1 Bottle Thermal Paper- 02 No , Digital Video Colposcope Brand - Bpl/Maestros/Bistos Specification 1. Should Have Led Cold Lighting System Reproduces An Original View Of Tissue. 2. Led Lights Are Replaceable. 3. Should Have Advanced And Fast Auto-Focusing System To Ensure Clear Image. 4. Should Have Remote Capture Control And User-Friendly Keyboard Layout For One Handed Operation. 5. Should Have Electronic Green Filter That Enhances Vascular Image Display Without Compromise Of Illumination. 6. Should Have Working Distance Of 6.7 - 11.8 (170 - 300 Mm). 7. Should Have Magnification Of 1X - 36X. 8. Should Have Resolution Of 3,80,000 Pixels Or More 9. Should Have Horizontal Resolution Of > 470 Lines. 10. Should Have Field Of View Of 0.4 - 5.9 (10 - 150 Mm). 11. Signal/Noise Ratio Should Be = 50 Db. 12. Should Have Signal Output Of S-Video, Pal/Ntsc. 13. Should Have Acetic Acid And Iodine Reaction Test Timer To Precisely Detect Low/High Grade Cin. 14. Should Have Real-Time Display Of Magnification. 15. Should Have Powerful Colposcopic Findings Gallery For Comparison Analysis. 16. Should Have R-Way Evaluation Program Supports Cervical Disease Diagnosis Guidance For Clinical Users. 17. Should Have Dicom 3.0 Supportive. 18. Should Be Manufactured By An Iso Certified Company , Vessel Sealing Device For Open Surgery Shaft Length-23Cm Curved Tip (Box Of 6)(A) Curved Jaw Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology. Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A} Curve Jaw Vesselsealer B) Should Be Able To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. C) Sealing Should Withstand 3 Times Systolic Pressure. D) Scaling Length 20 Mm; Cutting Length 18 Mm, Shaft Length 23 Cm; Shaft Diameter 5 Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. Technical Specification For , Vessel Sealing Laparoscopic Surgery, Shaft Diameter-5Mm, Length-37 Cm Jaw Type Curved Jaw Double Action With Contoured Tips, Shaft Rotation 350 Degrees, Jaw Surface-Textured Ceramic Stops.Jaw Aperture-13Mm Seal Plate Length- 20.3(Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Blunt Tip Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Sealing Length 20 Mm; Cutting Length 18 Mm, Shaft Length 37 Cm D) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness:Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. E) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Instrument For Open Surgery, Instrument Length 20.6Cm-21 Cm, Curved Jaw, Hand And Foot Switching(Box Of 6). Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Exact Open Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Instrument Length Should Be 21 Cm. D) Curved Jaw In 28 Degrees, Seal Length 19.3Mm, Cut Length: 18.5Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Device Laparoscopic Surgery. Shaft Diameter-5 Mm, Maryland Jaw Curved Device Length 37Cm (Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Curved Jaw Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec B) Sealing Should Withstand 3 Times Systolic Pressure. Scaling Length 20 Mm; Cutting Length 18 Mm, Shaft Length 37 Cm; Shaft Diameter 5 Mm C) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation D) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Device For Open Surgery With Shaft Length 18.8 Cm, Jaw Type-Curved Jaw (Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Small Jaw Open Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Instrument Length Should Be 18.8 Cm. D) Curved Jaw In 28 Degrees, Seal Length 16.5Mm, Cut Length: 15.5Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Ethelene Oxide Sterlization Machine ( Brand - Steri Techno Fab/ Map Industries) 1) Eto Gas Sterilizer Should Be Fully Automatic Type With Software-Controlled Operation System For Low Temperature Sterilization Of Heat And Moisture Sensitive Medical And Surgical Items. 2) The Chamber Should Be Preferably Rectangular With Capacity Of 250 Litters Or 9 Cu. Ft. & Dimension 48”(L) X18”(W)X18”(H). 3) The Operating System Should Be Programming Logical Controller Based And Should Have Touch Screen Human Machine Interface From Where User Should Operate And Observe The Cycle . 4) The Inner Surface Should Be Smoothly Finished To Minimize Gas Deposits. 5) Manufacturer Should Provide The Test Report To Prove Conformity To Specification And Ability Of Eto Unit To Achieve Complete Pathological/Microbiological Elimination. The Test Of Report Has To Be Attached With Technical Bid Document. 6) Surface Heaters Should Mount On The Chamber For Uniform Temperature In Chamber Throughout Cycle. 7) Less Noisy And Vibration Proof Vacuum Generator Should Be Provided For Vacuum Instead Of Vacuum Pump. 8) The Machine Should Be Provided With Plc Based Automation Along With Lcd Hmi Which Allows The Operator For: (A) Change And Set The Parameters (B) Run The Cycle According To Pre-Selected Cycles. (C) Monitor Various Phases / Individual Parameters During The Process. (D) View On/Off Status Of The Various Components Of The Machine While The Cycle Is In Progress. 9) It Should Have Password Protection For Unauthorized Access & Analogue Input Of Process Pressure/Vacuum. 10) It Should Have Digital/Analogue Input For Temperature & Temperature Should Be Indicated In The Sterilization Area, By The Use Of A Temperature Sensor. 11) One Pressure/Vacuum Sensor For Display Of The Current Pressure/Vacuum, That The Load Should Be Subjected To, At All Times During The Process. 12) The Software Should Provide & Maintains Total Records Required For Process Parameters During The Sterilization Cycle. These Records Are Necessary For Meeting Ce Or En 1422 Norms Of Sterilization. 13) All The Fittings For The Accessories And The Main Vessel Should Be Fabricated From Ss 304 Stainless Steel. All The Valves Used In The Process Lines Should Be Ss 304/Brass/Teflon Construction Ball Valves. (All Standard Makes) 14) Pressure Testing And Vacuum Testing As Per Specified Standards. (1.5 Times The Working Pressure) 15) Automatic Operations As Well As Manual Operations In Case Of Technical Problems Should Be In Plc/Hmi. 16) Machine Should Not Open During Sterilization Process, It Should Be Open Only After Complete Cycle Of Sterilization. 17) It Should Be Plc Based Automation System. Plc Should Be Honeywell Or Siemens. System Should Be 21 Cfr Compliances. 18) Automation Should Be 7’’ Touch Screen Display Of Schneider Or Proface Or Equivalent. 19) The Construction Of Chamber Should Be Of Ss316 Grade Stainless Steel. 20) There Should Be Interlocks With Door Mechanism So Cycle Should Start Only After Closing Of Door. 21) Cartridge Puncture Operation Should Be Automatic Into The Chamber No Need Of Manual Puncturing. 22) In Case Of Cartridge Puncture There Should Be Alarm System. 23) One Complete Cycle Should Be Containing All Phases. Time Based Parameter Should Be Mention In Non-Editable Data Sheet. 24) Temperature, Pressure, Humidity, And Other Parameters Should Be Display In Hmi Screen. 25) It Should Be Noise Proof And Vibration Proof Vacuum Generator Should Be Provided For Vacuum Instead Of Vacuum Pump. 26) It Should Be In Built Aeration Phase To Remove Residual Gas Out From Sterile Item. 27) Pre-Requisite Sequence Phases Should Define To Run Cycle In Auto Mode. 28) Pre-Sterilization Phases Should Define To Create Proper Condition For Sterilization (I.E. Humidity& Temperature). 29) Post-Sterilization Phases Should Define To Remove Residual Gas From The Product. 30) Machine Should Have Manual Override Operating Facility. 31) Accessories Needs To Be Supplied With Machine: - ? Suitable Air Compressor Of 1 Hp Capacity. Air Compressor Should Be Oil Free And Less Noisy As Compared To The Traditional Oil-Based Compressor. ? 1 Nos Wire Mesh Type Basket For Loading & Un-Loading Of Sterilization Materials. ? Manual Sealing Machine Suitable Medical Use Sealing. Machine Should Operate On 240 V/50 Hz Operated And Make In India Product. Eto Gas Cartridge Of 1 0 0 Grams- 1 0 Nos. Eto Cartridge Should Be Of Same Make Of Machine. Bidder Must Have To Attach Msds Sheet Of Eto Gas Cartridge With Bid Document. 32) The Manufacturer Shall Have Below Listed Certification To Prove His Eligibility And Copy Of The Certificates Should Be Enclosed With The Offer. ? Iso 9001:2015 For Quality Management System. ? Ce Certificate For Eto Sterilizer & Eto Cartridge Compliance With The Requirement Of Directive Council Directive On Medical Devices 93/42/Eec As Amended 2007/47/Ec. ? Quality Management System For Medical Devices Iso 13485:2016 For Eto Sterilizer & Eto Cartridge. ? Risk Management To Medical Devices Iso 14971:2007 For Eto Sterilizer & Eto Cartridge. ? Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use - Part 2-040: Requirements For Sterilizers And Washer Disinfectors Used To Treat Medical Materials Iec 610102-040:2020 & Iec 61010-1- 040:2020. ? As Eto Gas Toxic And Carcinogenic Properties Environment Management System Certificate. ? Medical Electrical Equipment Iec– Part 1-2: Requirement For The Basic Safety And Essential Performance Of Multifunction Patient Monitoring Equipment. ? Iso 45001:2018 For Occupational Health And Safety Management System. ? Iso 20857:2010 And Rohs Directive (2011/65/Eu) On The Restriction Of Use Of Certain Hazardous Substances In Electrical And Electronic Equipment. ? Fda & Who-Gmp Certificates To Prove Standard Of Manufacturing Practice , Ot Light ( Brand - Shalya/Mattrix/Surgident) Description Of Function Led Surgical Lights Illuminate The Surgical Site For Optical Visualization Of Small Low Contrast Objects At Verifying Depths In Incisions And Body Cavities. 1. General Requirements 1.1. The Light Shall Adopt Led Technology To Create A Homogenous Light Patch Without Emitting Any Infrared Rays. 1.2. The Light System Shall Be Dual Light Heads, One Major And One Satellite. 1.3. Light Should Have Electronic Focusing From Control Panels Without Any Motorized Or Mechanical Movement Of Light Panels. 1.4. All Dome Should Have 2 Colour Led Lamps, White (Cool White) & Amber (Warm White) To Achieve High Cri And Get The Required Shade Of Light As Per Different Surgical Requirements. 1.5. High Power Leds Of 5Watts & Above Should Be Used To Provide High Lumen To Watt Ratio Which Leads To Lesser Energy Consumption And Low Heat At Surgical Area <2 Deg. 1.6. Lights Should Have Higher Watts Leds To Achieve High Lumen To Watt Ratio Which Leads To Lesser Energy Consumption And Low Heat At Surgical Area. 1.7. Pulse Width Modulation-Controlled Led Driving To Ensure Less Heating Of Led Which Increases Life Of Leds And No Change In Light Colour Output And Light Colour Temperature Throughout Life. 1.8. The Major System Shall With Automatic Illumination Control System With Sensors On The Light Head. When Some Part Of Led Is Masked By Surgeon’S Head Or Shoulders, The Remaining Led’S Will Become Brighter Automatically To Compensate For The Losing Illumination. 1.9. Light Intensity Shall Be Adjustable Between 30% -100% And Should Have Low Intensity Light For Endoscopy Mode. Light Intensity, Light Field Diameter And Color Temperature Should Be Controlled From Electronic Touch Control Panel Mounted On Light Arm And Wireless Wall Mount Electronic Touch Control Panel. It Should Also Have Provision To Control The Intensity, Electronic Focus, Depth From Sterile Field Though Capacitive Touch Control Handles. 1.10. The Light Head Shall Be Of Petalled / Winged Shape To Avoid Obstruction To Laminar Flow On Surgical Field. 1.11. The Color Temperature Shall Be Synchronized & Controlled By Either Light Head Control Panel. 1.12. The Light Shall Be Mountable To Ceiling From Single Center With 360-Degree Rotation Of All Arms. Spring Arms Shall Be Rotatable At Least 360 Degrees Around Its Own Axis. Each Dome Head Should Be Rotatable With 360 Degree At Connecting Joint With Spring Arm And At Least 300 Degrees Around Its Own Axis. This Feature Should Be Applicable With A Camera Mounted Dome Also. 1.13. The Maximum Movement Angle Of The Spring Arm Shall Be At Least Up 45°And Down 50 1.14. The Thickness Of The Light Head Shall Be No More Than 70 Mm. 1.15. Each Led Shall Be Replaceable Individually To Save Cost In Case Of Failure, Instead Of Replacing The Module With Several Leds. 1.16. The Surgical Light Should Be Complete With All Components For Celling Mount And Electrical Feed-In, Including Finalized Installation. 1.17. Detachable & Auto Cleavable Handle (3 Nos.) For Each Light Should Be Provided. 2. Technical Requirements Of Both Domes: 2.1 It Should Have 2 Colour Led Lamps, White ( Cool White) & Amber( Warm White) 2.2 The Central Illuminance Should Be 160,000 Lux 2.3 Light Field Diameter Should Be Adjustable From 150Mm To 300Mm 2.4 D10: 300Mm & D50 :160Mm 2.5 Color Temperature (K), Adjustable From 3500-5000K 2.6 Color Rendering Index Ra Should Be 95 Or More And R9 Should Be 93 Or More 2.7 Depth Of Illumination (L1+L2) As Per Iec 60601-2-41 (Ver 2003) Should Be 650Mm And As Per Iec 60601-2-41 (Ver 2008) Should Be 1200Mm. 2.8 Dimming Range Should Be Between 25-100% 2.9 Endoscopy Mode Illumination Should Be Less Than 5% Of 160,000 Lux 2.10 Number Of Led Bulbs The Light Head Should Not Be More Than 70 2.11 Led Service Life Should Be Minimum 60000Hrs 2.12 Light Head Dimension Should Be 700Mm (=/- 20Mm) 2.13 Max. Power Consumption Of All Light Sources Should Be Less Than 100W At Maximum Setting. 2.14 Power Supply Should Be 100-240V Ac, 50-60Hz 2.15 One Dome Should Be Ready For The Wireless Camera Attachment. 3.Standards • Iso 9001:2008 • Iso 13485:2003, • European Ce With 4 Digit Notified Body / Eu Ce With Eu Free Sale Certificate /Us Fda Registered . • Should Compliance With: Iec 60601-1, Iec 60601-2, Iec 60601-2-41, Certificate From Any Nabl Accredited Lab / Any Lab From Country Of Origin For Imported Brands , Suction Machine (Electrical) (Brand -Supreme / Goley) Type: Electrical Pump Type: Oil Immersed Rotary Vane Capacity: High Vacuum Voltage: 220 Vac, 50 Hz, 1 Ph Number Of Wheels: 04 (Antistatic) Air Flow: 35 Ltrs/Min Current: 1.8A Noise (Decibel): 30~35 Dba Power Consumption: 370W Weight: 25 Kgs Flow Rate: 35 Lpm Vacuum Gauge: 100Mm Reservoir Volume: 5000Ml Tubing: Non-Collapsible Suction Tubing Max Vacuum: -720Mmhg Motor:½Hp, Fhp 100% Copper Winding Rpm: 1440 Jars: Polycarbonate 2X2.5 Liters Capacity Filter: Bacterial Filter Autoclavable /Reusable Suction Machine Should Be Is I Marked , Fully Automated Biochemistry Analyser Brand (Erba Transia/ Meril) Random Access System With Stat Capability. Analytical Principle Spectrophotometry & Photometry, Turbidometry Principles. Assay Type End Point, Rate, Fixed Point, Kinetic, Ise (Optional). On Board Parameter - Present. Programmable Tests - Present. On Board Cooling For Reagent Present. Through Put - 200 Test/Hour Or More, Continuous Loading Facility. Sample Types Serum, Plasma, Urine & Other Body Fluids. Sample Volume 0-70 Micro Litres (Approx). Sample Quality Analysis, Clot Detection & Probe Crash Protection - Present. Reagent Volume 10 Microlitre To 300 Microlitre (Approx.). Total Reaction Volume 90 Microlitre To 350 Microlitre. Reaction Cuvettes - Permanent Glass Cuvettes With On Board Laundry. Possibility Of Replacement Of Individual Cuvette. Photometric Range 0-3.0 Od. 15. Wavelength-340-800 With Minimum & Standard Wavelengths (340, 405, 505, 546, 578, 600, 700 Nm) Calibration Autocalibration, Cooled Calibration Position, History Of Graphical Calibration Data Stored. Quality Control At Minimum 4 Level Qc Plot Westgard Rules, Twin Plot, Levey Jennings Graph, Cooled Qc Position. Data Storage Of Patient Present Proper System Of Storage Minimum Water Consumption. Warranty 5 Years Warranty Power Back Up Facility For Instrument. Autopipettes To Be Provided With Instrument 10 Micro Litre (Fixed) 01 Nos. 1000 Micro Litre (Fixed) 01 Nos. 0-100 Micro Litre (Variable) 01 Nos. 0-500 Micro Litre (Variable) 01 Nos. 100-1000 Micro Litre (Variable) 01 Nos. Demo Kit With Instrument Reagents Kits Provided With Instrument: Creatinine, Urea Uric Acid, Triglyceride, Sugar Cholesterol, Tp, Albumin, Sgpt, Sgot, Alkaline Phosphatase, Bilirubin Instrument: Usfda Registered And Ce Ivd Approved , Cbc Machine Brand -(Accurex / Erba/ Meril) Measurement Principle Electrical Impedance For Counting Rbc Wsc & Plateletscolorimetric Estimation Of Hgb At 540 Nm Parameterswbc, Ly#, Mid, Gr, Ly%, Mid%, Gr, Rbc, Hgb, Hct, Mcv, Mch, Mchc, Rdw-Cv, Rdw-Sd, Plt, Mpv, Pdw, Pct, P-Lcr, P-Lcc Throughput- 60 Samples/Hour Micro-Aperturewbc: 100 ?M Rbc/Plt:68 ?M Sample Typewhole Blood Or Pre-Diluted Sample Sample Volumewhole Blood (Venous Blood): 10 ?Lpre-Diluent (Capillary Blood) : 20 ?L Chamberdual Chamber: Rbc/Platelets & Wbc/Hgb Reagents- 3 Reagent System: Diluent, Detergent & Lyse (Non-Cyanide) Measurement Range Linearity Range Acceptable Limits Wbc0x10/L-10.0×109/L<= Plus/Minus 0.3 * 10 ^ 9 / L 10.1×109/L-99.9×109/L 0X102/L-1.00×102/L <= (Plus/Minus 5)%<= Plus/Minus 0.05 * 10 ^ 12 / L Rbc 1.01X102/L-9.99X102/L<= (Plus/Minus 5)% Quality Control - 4 Qc Options: L-J, X-B, X-R & X Qc Graphs Plotted With 31 Data Points Data Memory - Upto 100,000 (With Histogram) Display - 10.4 Inch Color Lcd With 640 * 480 Resolution Printer Built-In Thermal Printer Interface:Support Rs-232C, Standard Network Port And Usb; Keyboard And Mouse Operating Environment - Temperature: 15°C-35°C Electrical Specification-Fuse Specification: 250V/3A Humidity: = 85% Rh Frequency: 50/60 Hz Low: 1 X 3Ml/Normal: 1 X 3Ml/High: 1X3 Ml , Sthetoscope Brand- Bpl/Littman , Pulse Oxymeter Brand - Dr Trust /Beurer/ Bpl Specification Finger Chamber With Smart Spring System Accommodates A Wide Range Of Finger Sizes Pop-Up Menu To Setup Alarm Limits For Spo2 And Pulse Rate Low Battery Indicator Pule Rate: Yes Auto Power-Off: Yes Bright, Large Display For Better Visibility In Daylight Anti-Movement Feature Sturdy, Portable And Light-Weight Very Easy To Operate With Single Switch Operation Warranty ( Only Checking Warranty ) , Nebulizer Machine ( Brand -Bpl/Dr Trust) Operation Mode Table Top Size Compact Application Clinical Purpose, Hospital Medicine Cup Capacity 50 Ml Particle Diameter 1-5 Um , Pns ( Pereferal Nerve Stimulator For Nerver Block) Brand- B Braun / Vygon Sas/ Stimuplex Hns/2 Should Be Suitable To Identify Peripheral Nerves And Giving Percutaneous Stimulation In Neuro Muscular Block. - Should Have A Percutaneous Monopolar/Bipolar Stimulating Handle For Localization Of Nerves Without Puncturing The Nerve Which Should Be Autoclavable. - Should Have Selectable Stimulation Intensity Ranging From 0-60Ma In Steps 0.1Ma With Stimulating Handle And Stimulation Impulse Width From 0.3Ms, 0.5Ms And1.0Ms - Should Continuously Measure & Display Actual Current Passing Through The Patient And Selected Current -Should Have Pause Function To Interrupt Stimulation Without Delivering Impulses Test Function -Should Automatically Switch Off With A Acoustic Warning If Not Operated Over A Period Of 20 Mins -Should Have Lcd Display For Stimulation Current, Impulse Pattern, Pulse Width, Impulse Amplitude. - Should Have Analog And Digital Display Of Selected Current And Actual Current. - Should Have Membrane Touch Pads For Choosing Stimulation Function -Should Be Small (Pocket Size) & Light Weight. Should Be Ce Certified Or Usfda Certified , Nerve Locator With Needle Brand- B Braun / Vygon Sas/ Stimuplex Hns/2 Separate Output For Nerve Stimulator - Mapper And Locator For Safety. Automatic Switch Over From Mains Power Adaptor To Rechargeable 9Vbattery With Low Battery Warning Indicator. Feather-Touch Keypad For Easy Operation, Simple Setting And Extended Reliability. Variable Current Range As Per The Selected Mode(Impedane:0 To 5 Kohm). User Programmable Pulse Width And Frequency. Alphanumeric Lcd Display With Back Light. Automatic Shutdown For Power Saving. Audio And Back Light On-Off Option. Alarm: Audio-Visual-Alarm Is Activated If Flow Of Oxygen Falls Below 1Lpm. , Percussion Hammer Ss 304 , Tuning Fork 128 Hz Satinless Steel , Laryngoscope A Laryngoscope Is A Device Used In Medical Procedures To Visualize The Trachea By Inserting A Blade With A Small Light Into The Patients Mouth , Oxygen Concentrator Brand- Philips/Bpl/Deck&Mount 1. Flow Rate :-0-5L/Min 2. Purity 93+3% 3. Outlet Pressure(Mpa):-0.04-0.07 4. Sound Level :-<50 Dba , High Flow Nasal O2 Cannula (Brand- Drager / Niceneotech ) High-Flow Nasal Oxygen (Hfno) Therapy Delivers Heated And Humidified Oxygen At High Flow Rates (Up To 60 Liters Per Minute) Through A Nasal Cannula , Electric Needle And Syringe Destroyer Hub Cutter Stainless Steel With Auto-Cut Protection , Clinical Thermometer(Digital) , Medical Labrotary Refrigrator ( Brand- Remi / Vav Intruments) Capacity 600 Litres Temperature Range 2°C To 8°C Internal Configuration Adjustable Shelves And Storage Bins For Optimal Space Utilization Cooling Type Uniform Cooling For Consistent Temperature Distribution Display & Controls Digital Display With User-Friendly Controls Power Supply Energy-Efficient Performance , Refrigrator Domestic Single Door Godrej/ Kelvinator/ Bluestar Capacity 200 Litres To 265 Liters Temperature Range 2°C To 8°C , Wieghing Scale Mannual , Knee Hammer , Sahli,S Heamoglobinometer , Artery Forcef Staright 6 (Brand - Jj Instrument) , Double Hook Retractor Standard Size (Brand - Jj Instrument) , B.P Handleno 3 (Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 4 Mosquito(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 6 Medium(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 8 Long(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 9 Long(Brand - Jj Instrument) , Allies Forceps Big (Brand - Jj Instrument) , Allies Forceps Medium (Brand - Jj Instrument) , Allies Forceps Small (Brand - Jj Instrument) , Mayo Scissior Str 5 ½ Sttilette Edge(Brand - Jj Instrument) , Mayo Scissiorcvd 6 ¼ Sttilette Edge(Brand - Jj Instrument) , Scissors Straight 6 Medium(Brand - Jj Instrument) , Scissors Straight 5 Small(Brand - Jj Instrument) , Scissors Straight 8 Big(Brand - Jj Instrument) , Steinman Pin Introducer Ss(Brand - Jj Instrument) , Towel Clip 6 Big(Brand - Jj Instrument) , Towel Clip 4 Small(Brand - Jj Instrument) , Wire Cutter 9 Standard Size(Brand - Jj Instrument) , Detnal Wire Standard(Brand - Jj Instrument) , Langenbeck Retractor Medium(Brand - Jj Instrument) , Langenbeck Retractor Small(Brand - Jj Instrument) , Langenbeck Retractor Big(Brand - Jj Instrument) , Cats Paw Retractor Standard Size(Brand - Jj Instrument) , K-Wire Cutter With Tungsten Carbide Tip 7 Standard(Brand - Jj Instrument) , Hintermann Distractor Medium(Brand - Jj Instrument) , Mippo Wire Passer For Long Bone Large(Brand - Jj Instrument) , Wire Bender Standard Size(Brand - Jj Instrument) , Kocher Clamp 8 Standard Size(Brand - Jj Instrument) , Glucometer (Brand-Dr Trust / Dr Morphen/Accucheck/Accurex) Fast Result In 5 Seconds Small 0.5Ul Blood Sample Size Large Memory. 10 Lancets Minimum Blood Sample: 0.5 Microlitre ; It Features A Large Display Screen That Can Store Up To 300 Test Results , Vortex Mixture (Brand -Remi /Borosil/ Benchmark) Type Of Product Cyclomixer Shaking Movement Orbital Orbital Diameter (Mm) 4 Motor Type Shaded-Pole Motor , Bio Saftey Cabinet Type-Ii A Microflow (Brand - Microflow / Thermofisher) Specification Material Of Construction (Main Body) Crca/Gi Powder Coated/Stainless Steel 304 Material Of Construction (Work Table) Stainless Steel 304 Dimensions External (Wxdxh) -1950 X 900 X 2250 Mm Internal (Wxdxh) - 1830 X 610 X 610 Mm Average Air Velocity - 90 ± 20% Fpm Hepa/Ulpa - Efficiency 99.997%/99.999% Class Level - Iso 3/5 (Class 100) Noise Level - 65 ± 5 Db Electrical - 230 V, 50 Hz, Single Phase Special Features - Motor Driven Front Door, Alarm, Hepa Filter Blockage, Timer For Uv Light, Power Socket Inside The Cabinet Pressure Sensor Monitoring, Digital Airflow Verification, Interior Eye Level Display, Display Parameters Including Down Flow Air Velocity, Total Operating Hours. Standards Us Fed Std 209 E, Iso 14644-1, Iest-Rp-Cc-002-2, Bsi Certifications- Ce & Iso , Co2 Incubator (Brand - Remi / Thermofisher) Specification Chamber Volume (150 Liters) Sensor Infrared Co2 Heating Method Air-Jacketed, Pid Control Co2 Range 0~20% V/V Co2 Control Resolution ± 0.1% (Ir Sensor) Temperature Range Rt+5~55°C Temperature Stability ± 0.1°C Humidity Method Natural Vaporization > 95% Co2 Recovery (Door Open 30S, Recovery To 5%) = 3 Min Temperature Recovery (Door Open 30S, Recovery To 37°C) = 8 Min Shelves 2 3 Interior Dimension (Mm) (W X D X H) 400 X 450 X 500 480 X 530 X 610 Exterior Dimension (Mm) (W X D X H) 590 X 687 X 790 670 X 767 X 880 Supply:220-240 Volts, 50 Hz Single Phase , Binocular Microscope - Olympus( Model Ch21i) / Magnus (Model- Pzb 22) (Specification) Optical System: - High Contrast Finite Colour Corrected Optical System Magnification:- 40X To 1000X Visual Magnification. Stand: Aluminium Die-Cast Stand With Hand Rests For Enhanced Comfort And Stability. Observation Head: - Sidentopf Binocular/Trinocular Head, 360° Rotatable, Interpupillary Distance 53-75Mm, With Dual Diopteric Adjustment. Eye-Piece: - Wide Field 10X F.O.V 22Mm, Anti-Fungal & Anti- Reflection Hard Coated (Optional 10X/18Mm). Nosepiece: - Reverse Angle Quadruple Nosepiece (Ball Bearing Type) With Precise Click Stops. Objective: - Qusp Series High-Contrast Flat Shield Plan Din Achromatic Objective 4X, 10X, 40X (S) And 100X Oil, (S), Anti-Fungal & Anti-Reflection Hard Coated. Mechanical Stage: - Rack-Less X Axis Double Plate Stage, Size 190 X 125Mm (+-5Mm) With Cross Travel 90 (X) X 50Mm (Y) On Ball Bearing With Co-Axial Controls. Hard Coated Surface For Scratch Resistance. Double Specimen Holder Clip. Focusing Control: - Co-Axial Coarse And Fine Focusing On Gear Systems For Smooth Operation. Fine Adjustment 0.2Mm/Rotation With Maximum 2-Micron Scale Increment. Condenser: - Sub-Stage Moveable Abbe Condenser, Centerable, Na 1.25 With Aspheric Lens. Iris Diaphragm And Special Frosted White Filter, Swing-In, And Swing-Out Filter Holder. Light Source: Led 3.5W 3V Illumination With Variable Illumination Control Universal Power Supply 110V-240V, Ce Approved. Supply With: Power Cable, Immersion Oil, Spare Bulb (In Led Only) User Manual, Vinyl Dust Cover, Cleaning Cloth, And 01 Units Fuses Optional Accessories: - Wooden Carrying Case, Pointers & Micrometre Reticules , Penta Head Microscope(Brand- Micron/Magnus/Weswox) Optical System- Infinite Optical System Viewing Head Inclination 30 Degree, Ipd: 48-75. 01 Piece Trinocular Head, Inclined At 30°, 360° Rotatable, Phototube With 100:0/50:50 Light Split With Sliding Prism. 04 Piece Compensation Free Binocular Head, Inclined At 30°, 360° Rotatable With Diopter Adjustment. Eyepiece-10 Pairs Of Wide Field Eyepiece Wf10x/22Mm Nosepiece- Inverse Quintuple Nosepiece. Objective Plan Achromatic Objective 4X Plan Achromatic Objective 10X Plan Achromatic Objective 20X Plan Achromatic Objective 40X Plan Achromatic Objective 100X Condenser - Swing Out Condenser N.A.0.9/1.25 Focusing-Coaxial Coarse And Fine Adjusting System With Tightness Adjustment And Upper Limited, Coarse Adjustment Range 30Mm. Fine Adjustment Precision: 0.002Mm Attachment- Multi Head Attachment And Support Stand. Stage- Ceramic Coated Double Layers Mechanical Stage Of 185X142 Mm With Capacity To Hold Two Slides At A Time With Slide Catcher On Left And Motion Control On Right Hand Side Illumination- External Illumination, Led 12V 100W Pointer - Multi Colored Ponters With Intensity Controllable Led Colored Indicator (Blue, Green And Red Led) Pointer 360 Rotatable, Brightness Adjustable, Arrow Control Sticks And Color Selection Dial. Video Adapter C Mount 0.5X Camera - 8Mp Hd Camera 4K Resolution With Removable Hd Card With Sd Card And Compatible Software. Display-43 Inch Hd Display Connected To Penta Head Camera For Live Display With Suitable Stabilizer For Display. Certifications - Ce(Notified), Ios 9001 (Iaf Accredited), Ios 13485 Warranty: 1 Year , All In One Pc ( Brand- Hp/Dell/Lenovo) All-In-One Pc 13Th Gen Intel Core I5 27 (68.6Cm) Fhd 16Gb Ram, 1Tb Ssd, Intel Uma Graphics, 710 White Wireless Keyboard And Mouse Combo (Windows 11 Home, Mso 21, Shell White, 6.72 Kg) 27-Cr0407in , Desktop ( Brand- Hp/Dell/Lenovo) 13Th Gen Intel Core I5 27 (68.6Cm) Fhd 16Gb Ram, 1Tb Ssd, Intel Uma Graphics, Wired Keyboard And Mouse Combo (Windows 11 Home, Mso 21) 27-Cr0407in , Air Conditioner( Brand- Hitachi/ Bluestar/ Daikin/ Carrier) Ac 1.5 Ton05star Smart Inverter Ac With Installation & Extra Wire /Pipe , Air Conditioner( Brand- Hitachi/ Bluestar/ Daikin/ Carrier) Ac 2 Ton05star Smart Inverter Ac With Installation & Extra Wire /Pipe , Lithium Battery 1500Wh Battery 48W 120Ah ( Brand- Luminous /Amaron) , Executive Premium Office Chair, Leather “Adjustable Arms Ergonomic Chair Must Behigh Back ( Brand- Godrej) , Office Table4x3 Feet( Brand- Godrej) , Mid Back Office Chiar ( Brand- Godrej) , Revolving Stool ( Brand - Aliza /Godrej) 3 Leg Ss Top Powder Coated Thicknessminimum- 14 Gauge , Steel Almirah W X H X D: 91.44 Mm X 197.866 Mm X 485.140 Feet For Office Use(Brand- Godrej) , Xerox Machine (Hp/Canon/Ricoh) Print Duplex, Copy, Scan, A3 Black And White Laserjet Printer, Enterprise Departments/ Distributed Workforce, Laser Printers Print Speed Is Up To 22 Pages Per Minute (Ppm) For Black And White Printing , Imcubator Electrical 23 Lts Thermostat , Centrifuge Machine Clinical ( Brand - Remi /Benchtop) , Salters Baby Wieghing Machine , Oto Scope , Chloroscope , Horrock,S Appratus Portable , Sound Level Meter Decible Meter With Lcd Display , Water Depth Sampler , Vaccine Carrier , Mosquito Catching Kit , Craft Water Testing Kit
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
21.
Heavy Industries and Public Enterprises #10390733 AOC
Vertical Extension & Other Development Works at Academic Block Annex-2 Palayad Campus, Kannur University, Kannur, Kerala under PM-USHA scheme- 1 Civil work -General Structural work 2 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge25 mm average thickness 3 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter 4 Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. 5 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar 6 Core Cutting of RCC slabs(12cm Maxi.thickness) by using mechanical core cutting equipment of required diameter of the pipe in full depth etc to the satisfaction of engineer in charge including all cost and conveyance materials and labours charge etc complete (dia 80-200mm) 7 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 8 Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work ( Payment shall be made on the cross sectional area of R.C.C. or R.B work) as per direction of Engineer-in-charge. 9 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within alead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia 10 Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock 11 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 12 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 13 Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) 14 Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. 15 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 16 Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum). 17 Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 18 Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 19 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 20 Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts 21 Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) 22 Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges 23 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. 24 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more 25 Block work & Finishing Work 26 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 27 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 28 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) 29 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 30 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) 31 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 32 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats 33 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 34 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work 35 Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections. 36 Teracotta Clay Jali work, For Building work, minimum 7.5 cm thick as per approved design and pattern of Engineer in charge in super structure above plinth level upto floor V level with cement mortar 1:4 (1 cement : 4 coarse sand) with neat finish, polishing work all complete. 37 Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with Zinc coating of 120 gms/ (both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wallwith suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre.The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channelof 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufactures specification and direction of engineer in charge all complete.75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG),plaster board conforming to IS : 2095 : (part 3) 1996 (Board with BIS Certification marks) 38 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 39 For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 40 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides 41 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness 42 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm 43 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in- charge. 44 Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm 45 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 46 Joinery 47 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 48 Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer- in-charge. 49 Providing and fixing factory made uPVC white colour casement/casement cum fixedglazedwindowscomprisingofuPVCmulti-chamberedframe,sashand mullion(whereeverrequired)extrudedprofilesduly reinforcedwith1.60+/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriatedimension,EPDMgasket,stainlesssteel(SS304grade)friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mmsizeforfixingframetofinishedwall,plasticpackers,plasticcapsand necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)Note: For uPVC frame, sash and mullion extruded profilesminus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm). 50 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness 51 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood 52 Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin - charge using Anjili/ Jack wood 53 Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc 54 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 55 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm 56 Providing and fixing CP Brass Handle 450mm in all types of doors with the necessary fittings and arrangements all complete. 57 Providingand fixing chromium plated brass handles with necessary screws etc. complete:200 mm 58 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality, with necessary screws etc complete as per direction of Engineer- in- charge. 59 French spirit polishing:Two or more coats on new works including a coat of wood filler 60 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6 mm for diagonal braces and central cross piece 61 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1800X2250 mm. 62 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1000X2200 mm. 63 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately) 64 Providing and fixing SS H handle having min 45 cm length in toughed glass door including all necessary screws etc. complete. 65 Providing and fixing of glass door SS Patch Lock with out handle in toughened glass door including all necessary screws etc. complete 66 Fixing 12 mm thick frameless toughened glass partition of approved brand and manufacture, including top & bottom fixing arrangement and making necessary holes etc. for fixing required fittings, all complete as per direction of Engineer-in- charge. 67 Providing and fixing 3M Fasara frosted etching film of thickness 25 microns self- adhesive of approved colour, shade, and quality with cutting as per approved design and pattern, including cleaning of glass and making surface smooth for fixing of film to the surface, all completed as per the direction of the engineer in charge. 68 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover 69 Providing and fixing ball bearing for rolling shutters. 70 Sanitary and CP Fittings 71 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 72 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 73 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 74 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap 75 Providing and fixing ceramic urinal partitions of standard size as per direction of Engineer-in Charge and of approved shade 76 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore 77 Providing and fixing uplasticised PVC connectionpipe with brass unions: 30 cm length15 mm nominal bore 78 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:150 mm diameter 79 Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore 80 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore 81 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm 82 Providing and fixing white vitreous china laboratory sink with C.I brackets, C.P. brass chain with rubber plug 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required:Size 600x450x200 mm 83 Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in- charge. 84 Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. 85 Flexible pipe32 mm dia 86 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with C.P. brass screws and washers complete. 87 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 88 Providing and fixing SS grating of approved quality and colour. Rectangular type with openable lid150 mm nominal size square 100 mm diameter of the inner hinged grating. 89 Providing and fixing disabled friendly bathroom kit with all accessories including wash closet with soft close seat cover and cistern with twin flush setting, wash basin of min dimensions 510mm x 400mm with all necessary fittings including Angle cock, Connection pipe, waste pipe, Spatula Lever basin mixer, Wall mounted 600mm long, Wall mounted grab bar 600 mm long and wall mounted hinged rail 750 x 750, Health Faucet with angle cock. Recommended Makes : CERA , Hindware, Jaguar or equivalent . 90 Plumbing 91 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall32 mm nominal outer dia pipes 92 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall40 mm nominal outer dia pipes 93 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall50 mm nominal outer dia pipes 94 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes 95 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes 96 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore 97 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore 98 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore 99 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore 100 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall 101 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall 102 Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall 103 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow 104 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee 105 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63x50 mm dia Reducer 106 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 107 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 6Kgf/cm2 108 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2 109 Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall 110 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend 111 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee 112 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl 113 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia End cap 114 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow 115 Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall 116 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend 117 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee 118 Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl 119 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap 120 Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow 121 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer 122 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore 123 Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 124 Yard Plumbing 125 Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2 126 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling 127 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):With common burnt clay F.P.S ( non modular) bricks of class designation 7.5 128 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Single pushfit Coupler110 mm 129 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionBend 87.50110 mm bend 130 Tile and Granite work 131 Providing and laying Matt Finished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 1200 x 600 mm. 132 Providing and laying Matt finished Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, ofapproved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 1200x600 mm 133 Providing and laying Anti Skid matt vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. 134 Providing and laying premium vitrified bathroom wall tile in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. 135 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm 136 Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining ( veneer work), backing filled with a grout of 12 mm thick average in cement mortar 1:3 ( 1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 ( 1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade ( To be secured to the backing by means of cramps, which shall be paid for separately).Area of slab over 0.50 sqm 137 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade. Area of slab over 0.50 sqm 138 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 139 Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work 140 Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 141 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 142 Providing and fixing 12 mm thick gang saw cut, mat /rough finished granite, machine cut for steps, ramps or inclined plate form with raking and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 143 Structural steel 144 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 145 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 146 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 147 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 148 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 149 False ceiling 150 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board 151 Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit. 152 Rainwater Harvesting ,Fire Tank,Septic Tank 153 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock 154 Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock 155 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 156 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 157 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level 158 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 159 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm 160 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm. 161 Supplying and fixing C.I with frame for manholes: 600mm x 600mm ( heavy duty) the weight of the cover and frame shall not be less than 208 kg 162 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 163 Providing and placing on terrace (at all floor levels) Stainless Steel 304as per IS 5522:1992 of capacity 5000 Litreswith suitable fixing arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 164 Providing and fixing of Fire Rated door 1200x2100mm- Hollow metal fire doors at all levels from ISO 9001-2015 certified Manufacturer. Fire door should be as per NFPA 80 and NFPA 252. All fire doors should be tested at UL for 120 minutes and should pass both UL10B and UL10C. Doors shall be made from pressed galvanized steel confirming to IS277 as per following specification.Frame:Door frame shall be single rebate grooved profile of size 125 x 55 mm made out of 1.6 mm (16 gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self-tabs. Frames to have in build grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate ANSI UL labeled hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff and the gaps shall be sealed with silicon sealant.Shutter: Door leaf shall be 46 mm thick fully flush double skin door without vision lite. Door leaf shall be manufactured from 1.2 mm (18 gauge) minimum thick galvanized steel sheet.The infill material shall be resin bonded honeycomb core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI standard. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf.Door and frames shall be finished Pure Polyester Powder coated and shall have passed minimum 500 hours of salt spray test.Vision glass: The glass shall be 5mm clear fire rated glass of equal rating and not exceeding size of 114 sq. inches.Door Hardware: Stainless steel Ball bearing Hinges 3 Nos, Minimum 90Kg hydraulic surface applied rack and pinion door closers, Mortice Sash Lock with cylinder. One Side Handle and Other Side with 2 point Panic Bar. 165 Road Work 166 Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30 167 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. 168 Water proofing 169 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 170 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) 171 Landscaping 172 Supplying of Flowering Shrubs (Heliconiya st. Vincent red, Ixora bush, Cana durf etc..) 173 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removalof unsaverieable material?s as per direction of officer in charge (including cast of plant & water )Cost of plantation per trees plants (for 100 nos.=427.45/100) 174 Providing and Laying Landscaping of outdoor area with buffalo grass and small plants with all necessary levelling and filling as required. 175 Signage 176 Providing and fixing in position the signage board made out of 3 mm opaque PVC foam board of computerised cut, PVC non reflective self adhesive vinyl painted foam board of required size and colour. 177 Providing and fixing non lit Signages made of CNC Cut Stainless Steel projected letters and fixing it at site with all necessary fitting arrangements and accessories as per the design and requirement on instructions of the engineer in charge. 178 Furniture 179 Two tiered reagent racks (MS with powder coating) with granite top of 150 mm depth for side workbenches. The two tier should be placed at a minimum spacing of 300 mm. The item should be in compliance with IS 4209 (2013), NABL etc. The Length should be customized as per lab workbench and vertical posts must be placed at appropriate spacing. 180 Supply and Installation of Sink Module with SinkEach sink module should have a minimum dimension of 900 mm (L) x 900 mm (W) x 900 mm (H) and made of MS as per IS 1730 shall be designed with a single cabinet (with 2 shutter, SS304 hinges for easy and noiseless opening and closing mechanism). This module should include a sink made of 5 mm thick polypropylene with black color body. Minimum Dimension of the sink: 450 mm (L) x 600 mm (W). Sink should include PVC tap connection-15mm diameter (Goose neck type), grating etc. The sink module shall be portable and provided with 18mm thick granite table top (with cut out for providing sink). Item to be inclusive of all necessary fitting arrangement.The item should be in compliance with IS 4209 (2013), NABL, WHO etc. 181 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 750 mm D 182 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 890mm D 183 Supply, Installation, Testing and Commissioning of Eye wash with Brass inject mould with epoxy powder coated body with auto released Valve and cup shaped water dispenser with min 1/2 HP power pressure booster pump 184 Counter Height Stools :Supply and erection of counter height stools ( bar stools ) of following specifications : Revolving adjustable Chrome plated steel body chairs with resistance to the corrosion. Cushion Seat with Lift mechanism for Adjustment of height. Minimum height 750mm before expansion. Medium Back rest and arm rest. Item shall be of reputed make. 185 Office Chair: Non-revolving executive chair with fixed armrest providing natural resting for arms. Seat with PU cutted foam backed fabric, back rest with mesh type fabric, Upholstery: Heavy duty rubber backed fabric in BLACK ( Size -55x60 cm) 186 Executive Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 187 Revolving Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 188 Cabinet/Wardrobe: Providing and fixing Cabinet/Wardrobe unit with 18 mm thick Multi wood board with one side decorative and other side balancing lamination. cupboard shutters edge to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickel plated bright finishing M.S. piano hinges conforming to IS:3818 marked with fixing chromium plated brass 50 mm cupboard or wardrobe knobs, special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. Depth of shelves to be 300-600mm and shelves to be fix with proper support and bracket holders. as per layout drawing approved by Engineer in charge. Make laminate: Greenlam/ Merino / Century. Only front elevation will be measured. 189 Supply and erection of Airport type 3 seater waiting chair with powder coated chromium finish having minimum dimensions 1675mm length X 710mm width X 775mm total height and 400mm seat height . Seat: High quality cold rolled 1.2mm thick steel perforated sheet pressed and welded to form the shape. Arm & Leg: High quality 1.2mm thick MS Tube / Sheet . Cross bar: High quality cold rolled 2mm thick steel sheet pressed and welded to form the shape. 190 Table of size Min 2300x600mm Made of minimum 18mm BWR ISI (303 Grade) plywood (Century, Greenply, Fineply or equivalent). On top and all sides with 1mm thick hot press (3M or Henkel) laminates (Brand MERINO, Associates or equivalent) of approved colour and pattern as per the design. The table is provided with 1 drawer, 1 Storage, 1 key board locks, handles, mini fix, dowels and screws. Exposed edges to be finished with 0.8 mm edge band as per specified colour. 191 Supply of wooden table with one drawer and Cupboard unit made of hard wood varnishing/painting all complete. Size: 1200x600x750mm 192 Providing & supply of Conference Table with executive chair of 13 Pax with the following specifications.Table top size :3600 x 1200mm. Table Tops –made of 25mm thick MDF with waterfall top edges finished in PVC Membrane using unique wrap around technology for better aesthetics & long lasting use. Under structure – Legs made of 25 mm thick standard Black matt colour post formed panels interconnected with 18mm thick standard Black matt colour pre-laminated modesty panels, with height adjustable levelers to take care of uneven floors. Wire Management & Concealed wire management to take care of basic wiring requirements both horizontally & vertically. For closed configurations, liftable top cover, made of 12mm MDF finished in PVC Membrane, is provided to access the horizontal wire carrier. Vertical wire management is through flexible vertical wire manager, popup grommet with power & RJ45 Socket. Designed for Flexibility through modular Construction, PVC Membrane Finish Tops for seamless surface, Post formed Legs for safe use, Provision for easy wire management, Upgradeable / reconfigurable for future needs. 13 Nos Revolving adjustable type Medium height Back Office Chair with arm rest with back tilt and swivel mechanism constructed out of mild steel and high quality plastic. 193 Supply of wooded Chairs with armrest of Hard Wood Plank Seat and Reaper Back. 194 Supply of Wooden Bench and Desk made up of Mahagani of minimum size - Bench Size :1 83x30X46cm Desk Size :183x41x75 cm 195 Supply and installation of steel podium made of SS304 with min dimensions 500mm X 450 mm X 1200mm and having a sloped top surface, and having a decorative/ plain front face all made of SS 304 as per the design and approvals of the architect/ Engineer - In - Charge 196 Wiring-General Electrical work 197 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 198 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 199 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire 200 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 201 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 202 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 6 Sq.mm + 1 x 6 sq.mm earth wire 203 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 204 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 205 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 16 sq. mm + 1 X 6 sq. mm earth wire 206 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 207 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 208 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 209 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm 210 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm 211 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm 212 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair 213 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 214 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 215 Fixtures 216 Supply and Fixing suitable size modular GI box with cover in front on and providing and fixing 1 no RJ 45 including connections as required. 217 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). 218 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 219 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet 220 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) 221 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet 222 Supply and Installation of surface/recess mounted LED 2x2 luminaire with CRCA housing suitable with fully diffused diffuser for general lighting. The luminaire should have CRI > 80 and CCT of both 6500K/5700K, Cool White Light. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3700 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 36 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro or equivalent 223 Supply, conveyance and Installation of compact, 2 feet,10-15W,LED tube light with high lumen giving soft glare free light including all required mounting accessories, frames complete. (Philips/WIPRO/Havells or equivalent) 224 Supply, Installation of surface mounted LED Tubelight. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 30 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 25k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make - Philips, Crompton, Wipro, Havells 225 Supply, Installation of surface/recess mounted LED Round/Square luminaire with CRCA housing suitable with fully diffused diffuser for general lighting in office areas. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 110 lumen/watt and Minimum system wattage of 10 -15 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro 226 Supply, conveyance and Installation of compact 10-15W LED Bulkhead Light giving soft glare free, Cool White light & complete with electronic driver including all required mounting accessories, frames, complete ( Make: Philips/WIPRO/Havells or equivalent) 227 Supply, Installation, Testing and Commissioning of 1400 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 228 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 229 Supplying, conveyance and Installation of 150-250 mm sweep,1350 rpm, 3 - 5 blade BLDC Exhaust Fan including frames and all mounting accessories complete.Recommended Make: Atomberg Efficio/Crompton Brisk Air 230 Supplying, conveyance and Installation of BLDC Type Wall Fan having 3 blade, 400 mm sweep, Speed 1350 rpm, Air Delivery 70 CMM minimum, Wall Mount Fan including frames and all mounting accessories complete. Recommended Make: Atomberg Renesa/V-Guard ENVIRO WF BLDC/Havells Platina 231 Supply, Installation, Testing and Commissioning of 450 mm sweep, 900 rpm heavy duty exhaust fan with louver in existing opening including making good the hole to suite the size of above fan complete with connections using 3 core 1.5sqmm multi core pvc sheathed copper conductor cable etc as required. 232 SITC of skirting light fitting with white LED 3 module along with suitable size modular metal box with inner and outer plates with all accessories. 233 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). 234 Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. lCD 235 Supply and installation of 2 Nos. 4 ft MS powder-coated hanging rods for tube lights, including supply and laying of 1.5 sqmm copper PVC insulated FRLS wire (3 runs: Phase, Neutral, Earth), necessary hardware (ceiling clamps, saddles, junction box, connectors), complete mounting, terminations, testing, and labour charges — complete in all respects. 236 Network and CCTV System 237 Supply of 16 ports Network Switch, Rack-mountable 10/100/1000 Mbps, Switching capacity 35.7 Mbps Features: Flow control, Layer 2 switching, auto-negotiation, auto- uplink (auto MDI/MDI-X), Weighted Round Robin (WRR) queuing, Quality of Service (QoS) Power: AC 120/230 V (50/60 Hz) complete. Make D-Link/TP Link/Cisco or equivalent 238 Supply Installation Testing and Commissioning of 32 channel embedded Linux NVR (Network Video Recorder), must connect 32 channel IP cameras, Should support min 2 SATA HDD and each should support Min 2TB and must record video simultaneously, (Recording Type: Continuous, Motion Detection, Alarm, Smart Event, Event Motion Detection, Alarm, Smart Event), Video Compression H.265(HEVC)/H.264+/H.264, 2 Year Warranty, Image quality should be maintained throughout the warranty period. Make: CP Plus/Hikivision/Dahua or equivalent 239 Network Switch for CCTV. 16 Port PoE Switch 1000BASE-T Copper Ethernet PoE+ connections, 10M/100M/1G RJ-45 copper ports, 1000BASE-X Fiber SFP ports, 16 port Auto sensing 10/100/1000 Mbps PoE, minimum CPU memory 512 MB with 2 SFP/combo ports, Energy Efficient Ethernet (IEEE 802.3az) Make: CP Plus/Netgear or equivalent 240 Supply, Conveyance and Installing of 2MP IP Dome/Bullet Camera having Progressive Scan True Day and Night Colour IR Camera having effective pixel of 2 MP, Video frame rate of 2MP @30FPS, Minimum illumination of 0.01 [email protected], 0 lux@IR On, 20 M IR Range, 24 IR LED, AWB, AGC, BLC, 2D Noise reduction, with 3.6mm board lense, 12 VDC, PoE IP67 rated weatherproof performance. 1 year warranty. Make: Bosch/CP Plus/Honeywell or equivalent 241 Supply and fixing of 6U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete 242 Supply Installation Testing & Commissioning of 16 Port Loaded Cat 6 - U/UTP Modular Toolless Patch Panel having a metal structure enabling them to be durably fixed to the uprights of the 19 chassis. Include rear cable manager to hold cables without need for cable ties. The termination of I/0s shall be without any manual crimping tools. 243 Supply and fixing of 4U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete. 244 Supply and connecting 2 meter long CAT6 cable Patch cord having RJ45 connectors crimped at both ends, to the existing outlets as required. Make: D-Link/TP-Link or equivalent 245 Supply and Installation of LED Color display of minimum 32 inch screen, complete, UHD display Make: LG/Samsung/Panasonic or equivalent. 246 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable 247 Supply, Installation and Integration of Dual Band WiFi Access Point on false ceiling along with accessories, having Fast Wireless Speed, simultaneous 2.4GHz 300Mbps and 5GHz, 867Mbps Dual Band connections for 1.2Gbps of total available bandwidth, Superior Coverage of Four Fixed External antennas provide stable wireless connections and optimal coverage, App Control, Interface of 1× 10/100 Mbps WAN Port and 4× 10/100 Mbps LAN Ports having Working Modes (Router Mode / Access Point Mode). Make: TP-Link/Netgear/DLink or equivalent 248 UPS 249 Supply, Installation, Testing and Commissioning of True on-line Double Conversion 10 KVA UPS system with 3:3 Crest Factor Three Phase Input Three Phase Output. Inversion shall be Microprocessor controlled with instantaneous sine wave Control using IGBT. UPS shall have standard display features, alarms, safeties, etc Input Voltage range : a) Phase – Three Phase with ground b)Voltage range 190 VAC – 470 VAC c)Input Frequency :50/60 Hz d)Power Factor : 0.95 or above e)THD : less than 5% with full load Bypass f) Voltage Range – 200VAC – 240 VAC ) Frequency range – 45-55 Hz/55-65 Hz Output Voltage Range h)Voltage Range – 200VAC – 240 VAC i)Frequency range – 50/60 Hz j)Voltage distortion – linear load <= 2% k)Voltage distortion – nonlinear load <= 5% l)Output waveform – pure sinewave m) Crest Factor – 3:1 Minimum Back up time : Continuous 30 Minutes at full load Rectifier shall be Full wave Type (Shall fully meet the specified input power requirements) Battery Type: Sealed Lead Acid Maintenance Free DC Voltage : 96V DC System, Battery Nos and capacity shall be designed for optimum storage space. Installation &Commissioning Required Breakers also needs to be provided in input and output side for the UPS. Make: Liebert Vertiv/APC by Schneider/Numeric by Legrand 250 Cable Trays 251 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.375 mm width X 50 mm depth X 2.0 mm thickness 252 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness 253 Fan Clamp 254 Providing and fixing 16 mm S.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 255 DB and Switchgear 256 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) 257 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 258 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 259 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door 260 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 261 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural 262 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole 263 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 264 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 265 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps 266 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 267 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 268 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts C curve TP MCB complete with connections, testing and commissioning etc. as required. 269 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 270 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral 271 Earthing and Lightning Arrestor 272 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re- filling etc. as required. 273 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 274 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. 275 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 276 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 277 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 278 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 279 Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. 280 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube,having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 281 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 282 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 283 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 284 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG) 285 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) 286 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG) 287 Street Lights 288 Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 289 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps 290 Water Purifier 291 Supply and Installation of Water Purifier having Multi-Stage Filtration: RO (Reverse Osmosis), UV (Ultraviolet), UF (Ultrafiltration), Storage Capacity: 7-9 Liters, Purification Features: RO: Removes dissolved impurities, heavy metals, and salts.UV: Kills bacteria, viruses, and other microorganisms. UF: Filters out fine particles and microorganisms. Mineral Booster: Adds essential minerals to enhance water taste.TDS Controller: Adjusts Total Dissolved Solids for taste preference. ActiveCopper: Infuses copper ions into the water for added health benefits.Aqua Taste Booster: Enhances the taste and maintains optimum pH level. In-Tank UV Disinfection: Keeps stored water pure.Smart Display/Indicators: Alerts for filter change, UV fail, water level, and service needs. Super Fine Sediment Filter: Removes fine and coarse particulate impurities. Water Level Indicator: Monitors the purified water level in the storage tank. Make: Aquaguard Aura 7L/ Bluestar Aristo 7L/Kent Grand Plus ZWW 9-Litre/ LG 8L 292 LT Cabling and Termination 293 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 294 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 295 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp 296 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 297 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp 298 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm 299 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm) 300 Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 400 sq mm 301 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm) 302 LT Panels 303 Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work. General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall befl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 400A 3kA 4 Pole MCCB - 1no Ics = 100% Icu rating Digital Voltmeter 0- 500V with selector switch & Digital ammeter (0-400A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 400A. Out going : 250A ,50kA 4 Pole MCCB - 2no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 304 Lift panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 40A ,16-25kA TP MCB - 6 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list.Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 305 Sub Panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required. Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch &Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 32A ,16-25kA 4 Pole MCCB - 4 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 306 SSB2- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 250A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-250A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 250A. Out going : 1) 63A ,16-25kA 4 Pole MCCB - 8 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 307 Transformer 308 Supply , Installation, Testing and commissioning of 500 kVA outdoor unitized substation with an 11kV/433V dry-type cast resin transformer and a 630A VCB typically includes a compact prefabricated design conforming to IEC62271-202 standards, offering IP53/IP23 protection, and featuring compartmentalized construction to prevent accidental entry into energized areas. The substation is designed to withstand electrical impulses, thermal, and dynamic stresses, ensuring reliable and robust performance with low power loss and noise levels. The installation involves placing the substation on a prepared concrete plinth, connecting high-tension (HT) and low-tension (LT) cables, and ensuring proper earthing and safety measures. The commissioning process includes testing the transformer, switchgear, and protection systems to verify operational integrity. Make: Unipower/Intrans/Voltamp 309 MSB and APFC Panel 310 Supplying, installation, testing & commissioning of cubical type MAIN SWITCH BOARD suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having front surface area 6 sq.mtr (Approx.) fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 630 Amp capacity extensible type TPN aluminium alloy bus bars of height conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :- Interlocking:Electrical through advance contacts in MCCB/ ACB’s (incomers & bus couplers) and mechanical (castel key) interlocking should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possibility of accidentally approaching two supplies at one bus section.Interlocking b(I) Incoming : 2 Nos 800 Amps (DG and MAINS) each four pole ACB of fault breaking capacity 50 KA (Ics=Icu upto 433 V manually operated, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS 1397- 2 : 1993 as amended up-to-date complete with following accessories for each MCCB(a) Independent manual spring closing mechanism- 1 No.(b) Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection- 1 set.(c) Digital* type Voltmeter (0-500 V), with selector switch & back up HRC fuses/MCBs-1 set. (d) Digital* type Ammeter (0-.600 Amp), with selector switch and one set of 3 nos. CT’s of ratio. 800/5A Class I accuracy and 15 VA burden- 1set. (Ratio to be fi lled up).(e) 3 Nos. Phase indication LED lamps with 2 Amp back up HRC fuse, breaker ‘ON’ indicating light with 2 A HRC fuse, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.(f) Shunt trip coil 220 V A.C. (II) Bus Bars :TPN aluminium bus bars of minimum of 800 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec (II) Outgoing :(1) (a) 4 Nos. 250 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 250/5 Amps Nos. (c) Digital* type ammeter (0- 400 Ap) with selector switch set. (2) (a) 1 Nos. 200 Amp4 Pole MCCB for (Ics = 35 kA upto 433 V) (b) CT’s of ratio 200/5 Amps set (c) Digital* type ammeter (0- 250 Amp) with selector switch set. (3) 3 Nos 160 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 160/5 Amps set (c) Digital* type ammeter (0- 200 Amp) with selector switch set. The switchgears/measuring instruments shall be as per the Choice of the Engineer in charge. The panel shall be mounted on required structural steel supports and frames for mounting, the price quoted shall be inclusive of the same. The panel shall have suitable provision for connecting to the incoming cables of 3R x 400 sqmm XLPE Aluminium cables and shall be provided with necessary earth leakage relays as per the Inspectorate Norms. The panel shall be as per the IS standards and shall conform to all norms of EB/Inspectorate/CEA. Make of Switchgear : ABB/L & T/Schneider Electric/Siemens/Legrand 311 Design, Manufacture, Supply, Installation, Testing and Commissioning of Automatic Power correction Panel having Incomer: 250A, TPN MCCB, Digital Multifunction meter for V,A,F,PF With CTs CL:1 with RYB Indication lamps-1 Set 250A Aluminium bus bar with heat shrinkable insulation sleeves-1 set, Intelligent power factor controller with control MCBs etc. complete The panel shall comprise of suitable combination of capacitor banks upto a total of 100 kVAR and shall be designed as per the standards of Electrical Inspectorate/CEA. 312 DG and AMF Panel 313 Supply, Installing, Testing and Commissioning of & Silent Type& Diesel Generating set having CPCB IV+ acoustic enclosure having Prime Power Rating of 500 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor and consisting of the followings: Diesel engine radiator cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories. Engine mounted Instrument Panel fitted with and having digital display and necessary indication coupled to Synchronous alternator rated at 500 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor. Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. Daily service fuel tank of 440-460 litres capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. Dry exhaust manifold with hospital exhaust silencer and catalytic convertor. 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (lead acid type) as required as per specifications. Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications. 314 Design, Fabricating, Supply, Installing, Testing & Commissioning of automatic mains failure control including auto by-pass panel, suitable for 500 KVA silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH & provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required, all complete and inter locking including the following: (a) 1 Nos. 630 Amp., 50 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50-100% having adjustable OL & SC. Set at 350A (b) Auto/Manual/Test/Off selector switch (c) 2 Nos. over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay. (d) 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering(e) Energy analyser unit to indicate current voltage frequency power factor and KWH(f) Indicating lamps for load on mains and load on set(g) Fuse for instruments(h) Battery charger, complete with transformer/ rectifi er, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.(i) Main supply failure monitor(j) Supply failure timer(k) Restoration timer(l) Control unit with three impulse automatic engine start/stop and failure to start lockout.(m) Impulse counter with locking and reset facility.(n) ON/OFF/Control circuit switch with indicator(o) Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning. AMF Panel shall be connected to Main Switch Board incomer with necessary interlocking arrangement to prevent simultaneous switching on of power supplies. All integration between Main Switchboard and AMF Panel is under contractor scope. 315 HT Cable 316 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium powercable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 300 sq mm 317 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm 318 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm 319 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm 320 Air Conditioning Works 321 Supply, Installation, testing and commissioning of 3 x 3 Cassette type Air Conditioner of following capacity and specifications: Consisting of ceiling-mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of energy-efficient suitable rotary compressor for operation on single-phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation, with R-32/R-410A or equivalent refrigerant and fixing of room (fan coil) unit on ceiling, standard 5 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1 dia drain PVC pipe with insulation up to 5 m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. (Make: Voltas, Blue Star, Daikin, Hitachi, Carrier or equivalent). Minimum 2 TR 3 Star rated (inverter type AC) as per BEE 322 Supplying additional copper piping of required size and connecting the same to the available piping and extension of the same through 100mm PVC duct inside false ceiling. 323 Electrical Dismantling Works 324 Dismantling of existing outdoor transformer and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 325 Dismantling of existing DG set 100 kVA, AMF panel etc and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 326 Electrical Works- Fire 327 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm 328 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 329 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 330 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 331 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) 332 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) 333 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm) 334 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 335 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 336 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 337 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 338 First Aid Hose reel &Wet Riser system 339 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.a.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585b.20 mm nominal internal dia gun metal globe valve & nozzle. c.Drum and brackets for fixing the equipmets on wall.d.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m 340 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 341 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way-100 mm dia M.S. Pipe 342 Supply and fixing of Air release valve SS body of 25 mm dia (UL Listed). 343 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 344 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 345 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) 346 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304) 347 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel 348 Hose Box - Supply, Installation, Testing and Commissioning of Hose Box -Double door - (cabinet) to accommodate Two pieces of 63 mm dia fire hose along with one pair of 63 mm dia male & female couplings and one branch pipe. The cabinet is made of MS sheet, painted in approved red colour with glass fronted hinged doors and lock &key (UL Listed). 349 Supply and Installation of Fire Brigade Draw-out Collecting head of CI Body having gunmetal 63mm dia instantaneous male draw out confirming to IS:903 suitable to fit on 100mm dia pipe with necessary flanges, rubber gasket, nut & bolts and other items. 350 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 351 Fire extinguishers 352 Supply &installation of ISI ABC type fire extinguisher of 4 kgs. Make SAFEX/ MINIMAX / CEASEFIRE or equivalent(UL Listed) 353 Supply &installation of CO2 type fire extinguisher of 4.5 kgs. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 354 Supply & installation of water mist type fire extinguisher of 9 liters. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 355 Supplying & Installing of Clean agent based automatic modular fire extinguisher (ceiling mounted) suitable for A,B,C class fires & electrical fires, Capacity- 5Kg 356 Supplying & Installing of Mechanical Foam (Stored Pressure) Type fire extinguisher of 9L capacity with mounting clamp. ISI approved. Make : SAFEX/MINIMAX/CEASEFIRE or equivalent 357 Fire Pumps & Fire Panel 358 Electric driven Main Fire Pump: Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.1620 lpm at 56 m Head 359 Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads. 1620 lpm at 56 m Head 360 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)a.Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325.c. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. As required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 56 m Head 361 Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector switch & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING (Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.Jockey Pump63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROLControl for diesel engine comprising - Automatic/Manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller.Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification 362 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 150mm 363 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 80mm 364 Supply and Installation of 12V DC, 200Ah maintenace free battery suitable for Diesel Engine driven fire pump operation with required connect cable set, battery stand. 365 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 100mm 366 Signages 367 Supply and fixing in position Exit Signages photo luminescent type with indication arrows and letters Exit/Fire Exit/ Staircase/FIRE/Fire Station/Fire Fighting Equipment/Fire Duct/ Fire Extinguisher/ Floor/Fire Command Centre/Fire Pump Room/ No Smoking / Danger/ Call point / Sounder Identification Numbers (Ground/ 1st/2nd)/ In case of the fire do not use lift, use stairs and other mandatory signages recommended by Fire Departments having dimension 30 cm x 15 cm complete inculding fixing mechanism. 368 Supplying and Installing in position the signages approved by Kerala state fire service - of minimum size 1ft x 1.5ft made out of PVC rigid sheet 3mm thick with computer cut PVC non- reflective self adhesive imported vinyl painted on the front of PVC rigid sheet complete with wall mounting arrangements with mirror screws. with lettering- ASSEMBLY AREA 369 Signboards: Supply and Installation of Fire Escape Plan with fire fighting equipment location, exit in A3 Foam sheet with plastic lamination with necessory accessories to fix it on wall. 370 Supply and fixing in position & Fire Order& signage in suitable size made of high quality PVC foam sheet with photo luminescent lamination to make it glow automatically in the dark, with suitable arrangement to fix it on wall. 371 Supplying & fixing in position Assembly Point sigange in suitable size on aluminium composite panel with suitable stand to fix it on open area outside building. Assembly Point 372 Terrace pump 373 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)a.Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325.c. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head 374 Design, Supply, Installation, Testing, and Commissioning of an Automatic Terrace Fire Pump Panel, including:- IP54-rated enclosure with powder-coated CRCA sheet steel.- 32A 16kA MCCB, 15 HP-rated pump 3P contactor, overload relay, and pressure switch for automatic pump operation.- Auto/Manual selector switch, START/STOP push buttons, hooter, timer, and protection features (dry-run, phase failure, etc.).- Indicators (Power ON, Pump Running, Fault, Low Pressure), meters (Voltmeter, Ammeter with selector switches).- Copper wiring, termination, and provision for cable glands.- Installation, onsite calibration, and full functional testing for pressure-based automation. 375 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 376 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 377 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 378 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 379 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100mm dia 380 Pressure Guage-Supply, Installation, Testing and Commissioning of pressure guage, 4 & dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 381 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations (UL Listed).20 mm dia Make : Kartar/ Atom 382 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 383 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 384 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 385 Above Ground Piping 386 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia 387 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia 388 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia 389 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :250 mm dia (wall thickness 6.3 mm) 390 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150 mm dia 391 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :200 mm dia (wall thickness 6.3 mm) 392 Supply and Installation of 80mm dia M.S. &C& Class Diesel Engine exhaust pipe duly insulated with 50mm thick Glass wool with 1mm thick aluminium sheet cladding with bellows, flexible joint, necessary support, making hole in brick wall for pipe installation.Pipe dia 80mm 393 Underground piping 394 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 150 mm. Make - TATA / JINDAL 395 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 200 mm. Make - TATA / JINDAL 396 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (1m below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 100 mm. Make - TATA / JINDAL 397 Valves, measuring devices & switches 398 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required:200mm dia 399 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required80 mm dia 400 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 401 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required150 mm dia 402 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80mm dia 403 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150mm dia 404 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.150mm dia 405 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. 406 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 407 Pressure Gauge-Supply, Installation, Testing and Commissioning of pressure gauge, 4 dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 408 Supply and fixing of Air release valve Brass body of 25 mm dia (UL Listed) following IS standards, with required pressure rated. 409 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 410 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 411 MOEFA system, Automatic Detection & Fire Alarm System 412 Supplying, installing, testing and commissioning approved make Microprocessor based Multi-loop, Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 trouble events including1000 alarm log history events, Self Programmable alphanumeric keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 Loops. Each loop shall have a capacity of minimum 125 detectors & 125 other devices exculding 20% spare. The panel shall work in degrade mode in case of CPU failure, Products not having this feature may offer Redundant CPU. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition with the charging capacity of 200AH. The panel shall be capable of self programing without any dependancy on dongle or programming software. Quoted rate shall include supply of necessary software & hardware for progamming the panel with all necessary licence. Panel shall have Modbus over IP protocol for future integration with BMS. However, for present arrangement FA system will be standalone with 24x7 monitoring. The panel shall be capable of connecting to the cloud platform/solution. Complied to meet UL864, 10th Edition 6 Loop Networkable Addressable Fire Alarm Control Panel(Make: Honeywell or Equivalent) 413 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 414 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 415 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 416 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. 417 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 418 Supplying, Installation, testing & commissioning of external power supply unit provides regulated and filtered 24 VDC power for hooter operation.Battery backup with built in charging. 419 CABLING & WIRING Supplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 420 Miscellaneous 421 Preparation of initial and final drawings, submission to Panchayath, Municipality, KSEB, Electrical Inspectorate, Kerala Water Authority, State Pollution Control board, Fire Department, Factories and Boilers and other agencies if any for getting approval, sanction and No Objection Certificate for building permit and completion from Fire Department and other department. Quoted rate shall be excluding statutory fee (All statutory fees shall be borne by Client-actual statutory fees shall be reimbursed on submission of original bill/challans from authorities).
Contract Date: Jul 17, 2025 Contract Value : 11.48 Crore
Boards / Undertakings / PSU No of Bidders 1
22.
Public Administrative Department #10363312 Price Bid
Tender For Construction Of New Office Building Of Municipal Board Nawa - CIVIL WORKSClearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 2 Earth work in excavation by mechanical means (Hydraulic Excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils 3 Add extra for foundation/trenches/drains for every additional lift of 1.5 Mtr. or part thereof inAll kinds of soil 4 Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. 5 Supplying chemical emulsionin sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20% 6 Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion) . 7 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). (UNDER FLOOR) 8 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). (FLOOR UNDER FOOTING AND FOUNDATIONS 9 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M25 grade Design Mix by usingmin 410 kg of cement per Cum . 10 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M25 grade Design Mix by usingmin 410 kg of cement per Cum . 11 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix 12 Providing and laying in position Ready mix concrete manufactured in fullyautomatic Batching Plant andtransported to site intransit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge.All works upto floor V floor. Design Mix by usingM-25 grade concrete by using min 410 kg of cement per Cum 13 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 14 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : Walls (any thickness) including attached pilasters,buttressesplinthandstring course. 15 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 16 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Columns, pillars, posts and struts etc. 17 Add extra for additional height in centring, shutteringwhere ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at alllevels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan are is to be measured) 18 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.(Original producers who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Thermo-mechanically Treated bars (Conforming of relevent IS code) 19 Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Grade 304 20 Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m) fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.Hot finished welded type tubes. 21 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). 22 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) 23 Half Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 75 in superstructure above plinth level upto floor V level in. Cement mortar 1 : 6 (1 cement : 6 coarse sand) 24 Add extra providingand placing in position 2 Nos. ,6mm Ø M.S. barat every thirdcourse of half brick masonry 25 Providing and fixing Stone jali 40mm thick Red/Pink sand stone throughoutin cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali patterns to be cut square to jali slab without any chamfers etc: 26 Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 20mm thick . 27 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) 28 Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth completeNew Plastered Surface (three or more coats) 29 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect 30 Finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specificationsincluding primer coat and protecting coat including scaffolding and safety provisionTrowel Finish av. thickness 1500 to 2000 microns. 31 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade :Two or more coats on new work 32 Making of drip course (Tapka) in cement sand mortar 1:6 width upto 40 mmand 10 mm thick as per approved design 33 Making grooves as per design in plaster 10mm to 20mm wide. 34 P & F 1st quality Heavy Duty Vitrified Double Charged tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete.Size 600X600mm 35 size600 mm X 1200mm 36 P & F 1st quality Heavy Duty Vitrified glazed MAT tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. size600 mm X 600 mm 37 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 38 Extraforusingsize above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finishedtiles in place of 300mm x 300mm size. 39 Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm 40 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete For area of each slab upto 2001Sqcm 41 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. 42 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) Medium shade using approximately 50% white cement and 50% ordinary cement. 43 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.South Red1501 Cm2 to 3600 Cm2 Tiles 44 Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite/Kota Stone Work Full Edge moulding 45 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete 46 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete 47 Providing and fixing 1st quality standard Marble printed/ Granite Shade or Light/dark shad glazed tiles confirming to IS : 13753 & IS :15622 of size 300mm x 600mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 48 Providing and fixing wall panelling using soft wood frame of size 50x25mm @600 mm c/c in both directions duly treated with anti-termite treatment making grooves painting of grooves specification and drawing using : ISI 9 mm teak ply one side BWR 49 Providing and fixing pressed steel door frames confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applyinga coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4(M15 grade) complete as directed by Engineer-in-charge : Profile E 50 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A: 35 mm thick . Commercial Veneer both side 51 Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. 52 Providing & Fixing mica of approved make for inner/outer side of shutters with fevicol & nails completeas per approved by engineer in charge. 0.8mm thick mica 53 Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint 54 Providing and fixing fully panelled /partly panelleddouble leaf shutters frame for windows and ventilators as per approved design and drawings with approved steel fittings as per Annexure ‘A’ and width of styles, bottom and top rails 75mm including intermediate rails 50mm wide, beading of 25mm x 15mm size on both faces : 35 mm thickGhana wood grade I 55 Providing and fixing bright finished Mortice lock of approved make Godrej or equivalent withpair ofCP handles for doors with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge. 56 Providing and fixing of uPVC casement fixed windows or ventilators manufactured in ISO 9001:2000 & 14001:2004 certified company. Frame : Made from the Extruded uPVC Window Profile Section of size 60 x 60mm having outer wall thickness of 2.25mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2mm thick G/J/U/O TYPE GI section. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of acCumulated water, if any, to outer side. Fix Mullion made of 76 x 60mm uPVC Profile Section with steel reinforcement shall be provided in windows as per the requirement. Frame shall have ‘O’ type EPDM gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Glazing bead of size 34 x 20mm with ‘K’ & ‘O’ type inner and outer EPDM weather seal gaskets alongwith 5mm thick ISI make plain float glass.All welding joints of frame and shutter shall be cleaned and milled with the CNC mechanism to provide uniform grooved finish on all visible joints. Hardware : Installation at Site : Complete window is to be installed on site with 10 x 100mm fastners with white cap in existing pre-finished wall cut-out cemented to glass level plane at all height & width and silicon glue is applied to fill up the crevices between wall and window frame. Complete in all respect as per the drawing and specifications and direction of engineer-in-charge. (Insert 6mm tougend glass) 57 Providing and fixing of uPVC Sliding windows: Frame Made from the Extruded uPVC Window Profile Section of size 106w x 50h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2 mm thick GI section. Frame shall have three track configuration, two for sliding of window shutter and one for mosquito mesh shutter. Vertical member of frame which bears the sliding shutter load shall have aluminium rail/track for smooth sliding of shutter rollers. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side.Shutter : The shutter of sliding window shall be made of 39w x 69h mm Extruded 3 box multi- chamber uPVC Window Profile Section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5mm thick GI section duly mitered cut & thermal welded at all corners and fitted with uPVC glazing bead of size 22 x 20 mm with inner and outer co-extruded EPDM/TPE-Eweather seal gaskets alongwith 6mm thick ISI make plain float glass. Mesh shuttershall be made of 39w x 69h mm Extruded 3 box multi-chamberUPVC Window profile section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5 mm thick GI section duly mitered cut & thermal welded at all corners and fitted with nylon/polymer mesh and rollers/pully. (Insert 6mm tougend glass) 58 Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately). For fixed portionPowder coating aluminum( minimum thickness of powder coating 50 micron) 59 Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.)With float glass panes of 8 mm thickness 60 Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge.Pre-laminatedparticleboardwithdecorativelaminationononesideandbalancinglaminationonotherside. 61 Grading roof for water proofing treatment withwater proffing compoundCement mortar 1:3 (1 cement : 3 coarse sand) 62 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 63 Making khurras 450 x 450mm with average minimum thickness 50mm cement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1 : 3 and one coat of neat cement, rounding edges and making and finishing the out let complete. 64 Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg ofVG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. 65 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40mm wide and 4mm thick 66 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proffing cement compound @0.253 kg//sqm .This layer will be allowed to air cure for 4 hours. b) Second layer of slurryof cement @ 0.242 kg/sqm mixed with water proffing cement compound @ 0.126 kg/sqm This layer will be allowed to air cure for4 hours followed by water curing for 48 hours. The rates includes preparation of surface treatment & sealing of all joints ,corners,junction with polymer mixed slurry. 67 Providing&fixingprecastcementconcretecoping1:2:4mix50mmthickcompleteas per specification : 68 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-voilet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall confoim to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 5.0mm thick (Wt. 8.4 Kg./Mtr. Sq.) 69 Providing & fixing 12 mm thick tegular edge Glass Fibre Reinforced Gypsum False ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/Sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per 70 Providing and fixing 12.5 mm thick tapered edge gypsum board conforming to IS 2095- Part I at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting. 71 P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor 72 P & F water closet Seat Covers with brass hinges complete :Solid PVC (ISI marked) grade-I White for EWC. 73 P & F White Vitreous China Double Syphonic European W.C. (I.S:2556Mark) with mounted W.V.C. flushing cistern of (IS : 2556 Mark) of 10 litre capacity complete with all necessary internal fittings including cutting and making good the wall and floor. 74 P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: (Size 580x440 mm.) 75 P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall: :PVC with PVCbend as per IS : 7231 . 76 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : Size 630 mm x 500 mm dia for counter top 77 P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers. Size 600 x 450mm x 4 mm thick 78 Stainless Steel Sheet size 125mm dia. Heavy Quality of approved make 79 P & F Liquid Soap Container with brackets complete of approved make: C.P. brass 80 P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. 81 P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls and floors:15 mm dia nominal boreB Class 82 25 mm dia nominal boreB Class 83 P & F G.I. Pipes (External Work) with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc.15 mm dia nominal boreA Class 84 25 mm dia nominal boreA Class 85 50 mm dia nominal boreA Class 86 Concealed pipe in wall including painting with anticorrosive bitumen paint 15 mm dia nominal boreB Class 87 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: C.P. Brass bib cock,15mm nominal bore. 88 P & F Stop Cock(IS :8931 Mark),superior quality & ofapproved make: Brass 400 gm. 15mm nominal bore. 89 P & F Ball Cock (IS :1703 Mark) with Rod& P.V.C. Ball complete : Brass wt.Not less than 400 gm, 20mm. 90 P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc.C.P. Inlet connection 15mm.Brass (IS : 8931 marked) 91 P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :Gun-metal 15mm nominal bore. 92 Gun-metal 25mm nominal bore. 93 Gun-metal 50mm nominal bore. 94 P & F Gun-metal Non-return Valve or Check Valve (IS :Make) of approved make, superior quality:50mm nominal bore. Horizontal 95 P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved desig1000 Lt. Capacity 96 500Lt Capacity 97 Hoisting Charges for each floor :For ITEMS 2.26.1 TO 2.26.4 98 For ITEMS 2.26.5 TO 2.26.8 99 P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant110mm dia 100 160mm dia 101 P&FrigidPVCpipefittings(IS:4985mark)ofapprovedquality/makeincludingjoining the pipe with solvent cement rubber ring and lubricantCoupler (socket)75mm dia 102 110mm dia 103 160 mm dia 104 Reducer 110 X 75 mm110mm dia 105 160 mm dia 106 Plain Tee75mm dia 107 110mm dia 108 160 mm dia 109 Door Y110mm dia 110 160 mm dia 111 Bend 45110mm dia 112 160 mm dia 113 Bend 87 .5110mm dia 114 160 mm dia 115 Door Bend (Top Side110mm dia 116 Vent Cowel110mm dia 117 P- Trap110mm dia 118 Gully trap110mm dia 119 Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.Depth up to 0.5 M 120 Construction of Man hole, in all types of soil, inner size 1.5 x 1.2 M, with 450mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50 mm thick M-15 grade C.C. flooring making channels, 80 mm thick stone slab covering with 40 mm thick M-15 grade C.C.flooring, Ferro Cement cover with frame of 450mm dia, earthwork etc. complete including disposal of surplus earth within 50 mtr. lead as per design :Depth up to 1.5 M 121 Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. Inside size 450 x 450mm depth upto0.5 M Cement cover with frame 122 Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C flooring & over stone slab covering ,80 mm thick slab ,jointing of slab in CM 1:3. Ralthal, Kharanja,50 mm thick stone partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos C.I foot rests of approved design ,two No. 450 mm dia each Ferro cementcover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:- Size 400 x140x150 cm.(for 50 users) 123 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make75 mm dia 124 110 mm dia 125 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /makeCoupler75mm dia 126 110mm dia 127 Bend 87.5 Dg.75mm dia 128 110mm dia 129 Bend 45 Dg.75mm dia 130 110mm dia 131 Door Bend 87.5 Dg.75mm dia 132 110mm dia 133 Single Y75mm dia 134 110mm dia 135 Socket Plug75mm dia 136 110mm dia 137 Pipe Clip75mm dia 138 110mm dia 139 Nahani trap with jali 4110mm dia 140 Vent Cowel 110mm dia 141 P & F W.V.C. (IS: 2556 Mark) Squatting Urinal of standard make complete. Including cutting & making good the floor:Size 450x350mm 142 P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete.Flat Back (small) size 456x355x265mm. 143 Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.:Size 240 Cm. dia outside & 240 Cm. depth 144 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 145 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 Sqm on plan) including disposal ofexcavated earth, lead upto 50m andlift upto 1.5 m , disposed earth to be levelled and neatly dressed : All kinds of soil 146 Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. 147 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. :M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 40mm nominal size). 148 Providing laying, spreading and compacting specified graded crushed stone in sub-base course including premixing the material at OMC in wet mix plant, carriage of mixed material, laying in uniform layers with motor grader, F.E.loader on a prepared surface and compacting with vibratory compactorto achieve the desired density including all material, labour, mach-nery, lighting barricading and maintenance of diversion complete.[MoRTH specification Clause 401] includiong with all lead 149 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand ) including making joints with without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete including painting etc. as per direction of Engineer-incharge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineerin- charge). 150 M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 0.5 to 2.0 MSA for a design life of 20 years.) like city streets, small and medium market roads, low volume roads, utility cuts on arterial roads, etc Category A Denated units to key into each other on four faces zigzagshape as per IRC SP 63:2004 151 Construction oftubewell up to 100m depth and above to accomodate housing and assembly pipe in all types of alluvium strata by rotay drilling method with code of practice for construction and testing of tubewells (IS:2800 (Part-II) : 1991 and IS:2800 (Part-II) :1979 both amended up to date) with supply of bail plug if necessary.The work will not include cost of housing pipe and strainer pipe assembly cost, gravel and development work. Work would be deemedcompleted only after obtaining sound free water during pumping.200 mm nominal bore 152 Diameter 900 mm+C159Construction of Recharge Shaft in filter pit including Earth work Excavation , lifting excavted earth with all lift and 50 m lead and centering & shuttering evenever required. 153 Supply & fixing Pre-cast RCC Rinngs at the mouth of recharge shaft of M20 mix with40 mm thicknessDiameter 900 mm 154 Supply & lowering air line of 25mm dia, G.I. pipe B class having perforation 3 to 5mm size all arrow of G.I. pipe in Zig-Zag fashion & making air vent at top including the cost of Tee-Nipples, Elbow, Socket etc. 155 Supply and lowering vent air pipe 63mm dia rigid PVC pipe(IS 4985) mark class II (4kg per cm2 ) with required all necessary fittings including perforation of 3 to 5 mm size all around the pipe at a distance of 180 to 220mm in zig zag fashion and making air vent at top complete as per direction of Engineer incharge. 156 Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids Size 9 to 12 mm 157 Size 3 to 5 mm 158 Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids. 159 Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985. 200 mm Nominal Bore. 160 Supply and Fixing of Big steel Almirah overall size of916mm (W )x486mm (D )x1980 mm(H) with weldedconstruction. It should have the shelf thickness of 0.7mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high y eld strength) and all other components shall have a thickness of 0.9mm. The Almirah should have a Mazak handle and Three way locking mechanism with Shooting Bolts.It should have a height wise adjustable shelf mounting .Itshould also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated. Plenty of colour options and shelving options shall be available ISimarka brand (Godrej or equivalent) as per approved colour, shape,design,type by engineer in charge. 161 Supply and Fixing of small steelAlmirah overall size of 760mm (W )x455mm (D )x1325 mm(H)with welded construction. It should have the shelf thickness of 0.7 mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high yield strength) and all other components shall have a thickness of 0.9mm. The Almirah should have a 2 Mazak handle and Three way locking mechanism with Shooting Bolts.It should have a height wise adjustable shelf mounting.It should also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated.Plenty of colour options and shelving options shall be available ISimarka brand (Godrej or equivalent) as per approved colour, shape, 162 Providing and supplying Canning Chair of size 455mm X 580mm X880mm. IIshould have wooden canning support at back and bottom supported by steel frame 3 2mm thick,powder coated round pipe with full armwooden handles onsides and other fittings as per direction of enaineer in charae. 163 Providing and supplying Canning Chair of size 455mm X 580mm X880mm. IIshould have wooden canning 4 support at back and bottom supported by steel frame2mm thick,powder coated round pipe without woodenhandles as per approved colour, shape,design,type by 164 Providing and supplying Officer high back Chair, The seat and back are made up of 1.2 cm thick hot pressed plywood, upholstered with fabric and moulded Polyurethane foam with PVC lipping all around.The back foam is designed with contoured lumbar support for extra comfort. BACK SIZE:65.0cm.(W) X 71.0cm.(H) SEAT SIZE:65.0cm. (W) X 65.0cm.(D) andreinforced with M.S. insert. The armrests are scratch and weather resistant. The armrests are fitted to the seat with seaUarmrest connecting strip assembly made of steel.The center pivot mechanism Is designed with the followingfeatures:360 revolving type.Tilt tension 5 adjustment. Upright locking.The pneumatic height adjustment has an adjustment stroke of 12.5 cm..The pedestal Is made of HR steel and fitted with 5 nos.twin wheel castors (castor wheeldia. 5.0cm.). The pedestal is covered with a P.P moulded cladding for modem and aesthetic looks.The pedestal is 65.0 cm. pitch-centre dla.(75.0 cm with castors). The twin wheelcastors are injection moulded In 30% Glass Filled black Nylon, as per approved colour, shape,design,type by engineer In charge. 165 Providing & Supplying table or size 1500mmx900mmx750mm, Top should be nnished with 18mm MDF Bos:d post formed Both side with 0.6mm laminate of approved make & design & with appropriate balancer on the bottom or the top. All verticals supportsincluding Modestypanel should be of 18mm prelaminated MDF Board with 2drawers & 16 Swing door per approved design.The drawers to beprovided with ai:proved handles and fixed on Telescope channels.AppropriateEdge Bendings to be provided where necessary with PVC beading 2mm thick to be provided. Footrest to be provided with 1Bmm MDF prelaminated board of the same color code.P&F PVC wire managers capslo be provided on the table top, as approved colour,shape, design,type by engineer In Charge 166 Providing & Supplying side table of size 900mmx450mmx750mm. Top should be finished with 18mm MDF Bos:d post formed with 0.6mmlaminate oras same as the Table,approved make & design & with appropriate balancer on the bottom or the topAllvert icals supportspanel should be of 1Bmm prelaminated MDF Board. Having 2Drawers & 1Swing7 door CPU unit. Keyboard tray, with mouse rest to beprovided.Appropriate Edge Bendings to be provided where necessary with PVC beading 2mm thick to be provided as per design.The drawers to be provided with approved handles and fixed on Telescope channels.P&F PVC wire managers caps to be provided on the table top, as per approved colour, shape,design, 167 Providing and $Upplylng table of size 1200mmX 750mmX750mm high as per design. The table top should be finished with 0.6mm thick laminated postrorming on 18mm thick MDF board.The 3 drawer unit (provided withlocking mechanlsm)and all other8 exposed vertical supports should be finished with steel members or approvedshade,colour and make.Appropriate moulding/edge bindingto be provided where necessary with PVC beading 2mm thick lo be provided as per approved colour, shape,design, 168 Providing & Supplying Computer table of size 900mmx450mmx750mm.Top should be finished with 18mm MDF Bos:d post formed with 0.6mmlaminate or as same as the Table,approved make & design & withappropriate balancer on the bottom or the topAllverticals supports panel should be of 1Smm 16.00 Each 12100.00 1g3500.oo prelaminated MDF Board. CPU uni Keyboard tray,with mouse restlo be provided.Appropriate EdgeBendlngs to be provided where necessary with PVC beading 2mm thck to be provided as per approved 169 Providing & Supplying depository/cashcabinet made up of CRCA steel with external size or 5g1 x 460 x 460 mm,2 nos of lockable drawers and single door cabinet fitted 3.00 Each 22848.00 68544.00with 6 leverlock system 1vith completein all respect. (approx weight 160 kg to 180 kg) as per approved 170 Book Case - 4 Door Book Case shall have the configuration or 914mm(W)x320mm(D)x1742mm(H). The unique design provides the right rigidity to the Top hinged doors ,which shall faci itate easy use.The Book Case shall be made fromprime quality steel. It shall have a Rigid Knock Down Conslructlon.The TopPannel, Back Pannel and Side Pannel are made from 0.7mm high yield CRCA andother components from O.Smm CRCA. Each door shall have a 6 Lever Cam Lock with Comrron Key. 3mm thick glass should beused in each door for clear inside vision whih shall besecured Ina metalframe through a rubber gasket.11 Scissor Mechanism should be providedin each door for 20.00 Each 17248.00 344960.00receding Inside the top or every compartment andItshall ensure parallel and smooth movement. Each door should be provided with plastic side end caps as handle which Is easy to grip.Each compartment shall have a storage shelf with good capacity. The 4 Door Book Case shall have 18mm PLB Top straight edge with PVC lipping.The Hn shlngshall Include Epoxy powder coated.Complete work as per the as per approved colour,shape,design,type by engineer in charge. 171 150 cm high fencing of precast R.C. posts of 15cmx15cm tapered to 10x10cm at top placed at every 3m apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth posts to be strutted with same R.C. posts provided with 6 horizontal lines and two diagonals of black barbed wire between the two posts fitted and fixed with G.I. staples including earth work in excavation etc. complete 172 FIRE FIGTHING WORKProviding, Fixing, Jointing, Testing & Commissioning of Heavy duty MS C class (Heavy) pipes conforming to IS 3589 / 1239 part-I for hydrant and sprinkler applicationsincluding cutting, screwing, welding etc. & forged steel fittings like elbows, tees, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts including cutting hole and chase in brick or RCC walls/ slab and making good the same. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of requiredshade complete as required. (Pipe to be tested @ 10Kgf/Sqcm for 2 Hrs.). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 mm dia 173 100mm dia 174 80mm dia 175 50mm dia 176 40mm dia 177 32mm dia 178 25mm dia 179 Supplying and fixing first -Aid Fire hose reel Drum wall mounted swinging type with MS construction powder painted in post office Red, conforming to IS 884-1985 with upto date amendments, complete with the following as required.(A) Thermoplastic / Rubber Hose(B)20 mmdia UL, FM Bronze / SS nozzle with 5mm orifice (C)Drum and brackets for fixing the equipments on wall.(D) Connections from riser with 20/25 mm dia Brass/GM gate valves with screwed end and conforming to IS:778 Class-1through Forged steel Screwed Union & M.S. pipe. Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . With 30 m x 20 mm High Pressure Braided Rubber Hose as per IS:5132 - 1969and Bursting pressure 42 Kg/sqcm 180 Supplying and fixing of SS 304 Single / Double headed oblique pattern hydrant landing valve (internal/external) with 75 / 100 mm dia flanged inlet & 63 mm dia instantaneous type female outlet coupling with cast iron wheel complete with ABS cap and chain and all accessories as per IS:5290-93 (Type-A) in cluding matching flange (14 mm thick),nuts, bolts, washers, gaskets,etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Single Headed with 75 mm Dia. Flanged Inlet 181 Supplying and fixing of flexible hose made with 100% polyester, black EPDM internal rubber lining with External coat of synthetic elastomer (IS:636, type-A)63 mm dia, 15 mtr. Long RRL hose pipe with instanteneous type 63 mm dia SS-304male and female couplings(IS:903) duly bound and riveted to hose pipes with copper rivets and SS wire etc. as required.Appropriate Test Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. 182 Supplying & fixing SS-304 Short Branch Pipeconforming to IS: 903:93 fitted with 20mm (nominal internal diameter)bore nozzle, for projecting water in form of solid jet. The Branch shall have 63mm Male Instantaneous Inlet, suitable for use with 63 mm size Fire fighting hoses. H.P. tested to 21 kgf/cm² for 2.5 minutes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 183 Supplying and fixing of 750 mm x 600 mm x 250 mm Outdoor application Fire Hose Cabinet made of 1.6 mm thick MS sheetDuly powder coated in red color externally and white internally with 6 mm thick glazeddoors with Expanded Metal 2 mm thick Jali including necessary locking arrangement suitable to accommodate 2 Nos 15 Mtr. Long RRL Hose and 1 No. branch pipe on Existing Wall / Angle Iron Frame as required. (Cost of MS structure for mounting Frame is to be Paid Extra) All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 184 Providing and fixing of Fire / Electrical Shaft Door made frompowder coated (50 Micron) aluminiumpartialy glazed with 6 mm thick glass and Partialy/ Fully Louvered with Outer frame of AluminiumSection of Size 100 mm x 45 mm x 1.5 mmand Shutters Top, Middle & sideSection of Size 82 mm x 45 mm x 1.5 mm, Bottom Section of Size 110 mm x 45 mm x 1.5 mmComplete with Hinges, Tower bolt, Handle, Aldrop, Locking Arrangement including dash fasteners of required dia and size, necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. as per drawings and the directions of Engineer-in-charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 185 Supplying, Installation, Testing & Commissioning ofElectrical Driven fire fighting duty Terrace pump as per TAC andIS 12469-1988., Factory assembledin Pump make OEMsuitable for automatic operation and consisting of following details given asA, B, C, D, E, F, G and H.(A) Horizontal End suction Centrifugal Back pull type pump complete for delivery of below mentioned discharge and Head(B) Material of construction : Pump Casing - Cast Iron, Impellor- Bronze, Shaft - SS 410, Packing - Mechanical Seal(C) Squirrel cage induction motor (IE-3 Class) suitable for 3 phase, 415 V, 50 HZ, Ac supply , Class -F Insulation, Synchronous speed not Exceeding 3000 RPM, T.E.F.C confirming to IP:55 , of required HP suitable for the above pump ,along with flexible (Love Joy type) coupling , coupling guard complete in all respect .(D)Common bed plate fabricated frommild steel channel for installation of pump and Motor including anti vibration pads.(E) The Hydrostatic tests (2 times of design operating head or 1.5 times the shut off head whichever is higher) and performance tests (to determine developed head, Pump BHP and efficiency v/s Flow) of pumps along with trip test shall be carried out at manufacturer’s works in Virtual / Physical presence of Department’s representatives.(F) Physical & Chemical Test reports of i) Pump casing (ii) Impeller (iii) Shaft (iv) Shaft sleeveand Dynamic Balance certificate is to be submitted by OEM(G) Suitable size Reinforced cementconcreat (M-30) foundation with foundation bolt, Nozing Angle of size 40mm x40mm x5 mm ( Cost of RCC Foundation to be paid Extra )(H) Weather proof hood fabricated from 5mm thick UV stablised FRP sheet supported by 50 mm x 50 mm x 5 mm Angle Iron fram above pumpset to protect it from weather All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR 450 LPM with 35 mtr head 186 Supplying and fixing Inlet Breeching Connection of CI body with Gun Metal male instantaneous inlet couplings with Inbuilt NRV, Drainage Connection with 50 mm Brass gate valvecomplete with PVC blank cap and chain as required for 150mm dia Outlet with 1 no. Matching Flange (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following Ways. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 4 Way 187 SITC of installation control valve of cast iron body and brass/bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continous alarm when the wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150mm dia 188 Supplying and Fixing of PN 16 Cast Iron Dual Plate Wafer Type Check Valve / Non return valve with SS / Bronze flap complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 mm dia 189 100 mm dia 190 150 mm dia 191 200 mm dia 192 Supplying and Fixing of PN 1.6Butterfly Valve (Wafer Type) with S.G Iron Disc and confirming to IS:13095 complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 mm dia 193 100 mm dia 194 80 mm dia 195 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 6 kg 196 Supply & Fixing of CO2 type Fire Extinguisher conforming to IS:15683:2018, charged with CO2 gas (purity 99.7% conforming to IS 15222), Powder coated Internal & External Surface Manganese steel ISI marked as per IS 7285 cylinder body , Wheel type Forged brass release valve ISI Marked as per IS 3224 with Inbuilt safety release device ((Fusible plug and Rupture Disc Type), 1.0 Mtr. Metal wire braided hose having minimum bursting pressure of 140 Kgf/cm2, Horn with metallic thread connection, QR code for Product Traceability,including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSRCapacity 4.5 Kg. 197 Supplying and Fixing ofGalvanized Mild Steel fire bucket Confirming to IS: 2546 : 1974 with one coat of primer and two coat of enamel paint of approved shade on Angle Iron ( 50 x 50 x 5 mm) Stand of Size 800 x 1240 x 400 mm with MS 22 SWG Galvanized Canopy, 4 Hooks for Bucketsincludingassociated civil works etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 198 SITC of UL 10th edition / EN54 / VDS certified Addessable Manual Call point (MCP) with LED/ FIRE Indication Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 199 SITC of UL 10th edition / EN54 / VDS certified Addressable sounder with strobe light,Loop Powered / Direct powered from FACP with sound level 90 dB and programmablefrom the panel etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 200 SITC ofResponse Indicatorfor indicating the activation of the Remotely located Detector for Conventional type detectors as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 201 SITC of EN / LPCB/ UL listed / approved conventional automatic fire Alarm Rate of Rise cum fixed temperature thermister typeHeat Detectors , 12 / 24 volt D.C., visual alarm indicator (LEDs) Blink - green in stand by and Steady - red in alarm complete in all respectswith baseas required.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 202 SITC of EN / LPCB/ UL listed / approved conventional automatic fire Alarm Optical/Photoelectric type smoke detectorsof photo-optic sensing chamber, 12 / 24 volt D.C., visual alarm indicator (LEDs) Blink - green in stand by and Steady - red in alarm complete in all respectswith baseas required.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 203 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR2 x 1.5 sq.mm 204 3x 1.5 sq.mm 205 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR4 Pair 206 2 Pair 207 Supplying and fixingof CE certified and UL listed GI wire mesh cable tray made from spot welded steel wirehot dipped galvanised between 60 and 80 microns of zinc as per BS 729including horizontal and vertical bends, reducers, tees, cross members and other OEM made accessories like wall clamp, hold down clamps, Earthing terminal, brackets as required, and duly suspended from the ceiling with electro-zinc coated TF rods,etc. as required of following sizesAll as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .500 mm x 100 mm x 6 mm 208 300 mm x 100 mm x 6 mm 209 SITC of UL 10th edition / EN54 / VDS certifiedActive Repeater Panel for Fire Alarm System with inbuilt networking port (both RS485 & Ethernet),Serial port for printer,two supervisory inputs,two position key switch and USB port for programming. The Repeater Panel shall allow users to acknowledge, reset,silence, program, view hisory events.etc (All functions similar to main panel)The user interface of the repeater panel shall be same as the Main Controller with menu driven user interface with smart search.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 210 SITC of PA system Operator Console of following wattage to be installed withConventionalfire alarm systemcomplete with following capacity , channel mixing amplifier , 1 no cardioids goose neck microphone , 1 no professional grade cassette deck/ CD Player , 16 zone floor selector console ,equipment rack complete in all respects. PA system shall be coupled to the Fire Alarm System. Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 1x 240 Watt 211 SITC 6 watt Speakermounted in M S sheet box with perforated front mesh for PA and Emergency System. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 212 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRMedium point (up to 6 mtr.) 213 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRLong point (up to 10 mtr.) 214 Long point(up to 10 mtr.) 215 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRMedium point (up to 6 mtr.) 216 Long point(up to 10 mtr..) 217 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR3x 1.5 sq.mm 218 3x 2.5 sq.mm 219 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 220 2 x 6.0 sq. mm. + 1 x 4.0 sq. mm. 221 2 x 6.0 sq. mm. 222 4 x 10.0 sq.mm 223 4 x 16.0 sq.mm 224 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 225 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 226 Providing & Fixing ofof BLDC Technologyventilating fans , single phase with PVC impeller, ABS body, Double Ball bearing, automatic back lower shutterincluding making connection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .250 mm sweep with Min. Air delivery 1150 cmh, 1300 RPM 227 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 228 Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating 229 Three pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 230 50/63 A rating 231 100 A rating 232 Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 233 50/63 A rating 234 Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock,min. operation 10,000 upto 63 A rating and5000 for 100 Aratingand minimum phase termination capacity of 35 sq.mm. rigid wire, IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRTwo pole 30 mA sensitivity6A-32 A rating 235 40 A rating 236 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRGlazed door (single phase) IK-09 and IP-43 with Metal end box8 Way (8+2) 237 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box6Way(Incomer 8,Sub Incomer2+2+2) 238 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box withprovision of incomer suitable for MCB / RCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 100 A rating copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR6 Way(8+18) 239 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 240 Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,minimum width ofswitch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 25 Amp.2 Moduleswitch With LedIndicator 241 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 Amp. 2 Module Socket 242 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSRRJ-11 telephone jack Double line 243 RJ-45, Cat 6 computer jack with shutter 244 Providing & Fixing offollowing size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1 Module 245 4 Module 246 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR5 step fan regulator 2 Module 360 dgree rotating 247 Plate Earthingas per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 248 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 25mm x 6mm G.I. ( Hot Dipped) Strip 249 Supply & Laying following size B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 mm dia. 250 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1170mm(+/-10%) LED batten with min. lumen output 2200 lm 251 570mm (+/-10%) batten with min. lumen output 1000 lm 252 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Minimum lumen output 3600 lm 253 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Minimumlumen output 650 lm 254 Minimum lumen output 1950 lm 255 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 256 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR2 pair 257 Supply and Laying of PE Insulated, PVC Inner Sheathed, armoured & PVC Sheathed Telephone Cable. with 0.5 mm thick Solid Annealed Bare Copper Conductor as per IS: 8130/84 telephone cable confirming to TEC specificationsGR/WIR 06/03, Mar.-2002 in existing pipe / open trench / Cable tray / on surface including making necessary connection, testing etc. as required of size. For additional technical parameters of product / work refer Annexure A attached with this BSR50 pair 258 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 mm 259 Supplying and fixing of ISO Certified company made Krone module with base frameas per PWD specification for electrical Works, in the recess / surface made out of 16 SWG sheet steel box, front openable, having locking arrangements duly powder painted., including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .50 Pairs 260 CCTV SURVEILLANCE WORKSupply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Modular Patch Panel Loaded with Cat -6A I/O 261 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 262 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Cat 6A, Sheilded Information Outlet 263 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Single Aperture 264 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Modular Patch Panel Loaded with Cat -6A I/O 265 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 9 U Rackwith Width 600 mm & Depth 400 mm + 100 mm 266 Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent PoE Giga Ethernet Switch providing 24 x 10/100/1000 MBPSPoE Giga Ethernet ports and with min 4 SFP Giga Ports (provision for Fiber Giga connectivity) with provision of minimum Stacking of 06 Switches with minimum 370 Watt PoE Power Budget with related LAN Base Software including making connections etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 267 SITC of 2 MP IR Fixed Dome Network Camera -1/2.7″ Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.002Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Video tampering, UL, CE, FCC certified. 268 Supply Installation testing and commissioning of 32 Ch Network Video Recorder- Connect Up to 64 IP Cameras, Up to 12 Megapixels Resolution, HDMI1/VGA1 and HDMI2/VGA2 outputs provided, atleast one HDMI output with 4K (3840 × 2160), atleast one VGA output with 2K (2560 × 1440) resolution, Support H.265/MJPEG, Supports N+1 hot spare system, Supports RAID0, RAID1, RAID5, RAID6 and RAID10, Supports HDD hot swap, Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, 1 × eSATA interface, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 10 TB, Front panel: 2 × USB 2.0; Rear panel: 1 × USB 3.0, Alarm I/O 16/4, RS-232, RS-485, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface,Multiple network monitoring: Web viewer, CE, FCC, UL certified. with 30 days backup capacity asrequired. 269 SITC of professional PC alongwith printer and other accessories as required having minimum i7 processor, 8 GB graphic card 1 Tb SSD as per requirement. 270 SITC of 42 inch full HD professional LED display for CCTV monitoring. 271 External Electrical WorkS I T C of star ratedAluminium wound distribution Transformerof following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star - 1 & BIS approved as per IS 2026- 1977 & lossesas defined as per 2014 (Fourth Revision) Level-1 . including standardaccessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint,including carrying of pre-commission Testing & Charging of Transformer complete in all respect .The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including testing from CTLof discombefore charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 KVA 272 SITC of PLC Based Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stopcommands, control Relays , Ammeter & Voltmeterwith selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets: Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturer shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .20 to 40 KVA 273 Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as requiredcomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 274 Providing & Laying XLPE insulated three core ArmouredAluminiumcable for working voltage 11 K.V.(E) confirming IS :7098 P - 2withH4- Grade electrolyticaluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .3 core 150.0 Sq.mm 275 MAIN LT PANELSITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra )(d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 276 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR4 pole MCCB With Thermal Magnetic release160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 277 up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting 278 Supply and fixing of following accessories for Moulded case circuit breaker (MCCB)compatible to main MCCB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Shunt Trip Release 279 Under Voltage Release 280 Extended Rotary Handle 281 Auxiliary contact 282 Spreaders for 250A, 4 Pole MCCB 283 Spreaders upto 125A, 3 Pole MCCB 284 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 0.5 A to 5 A rating 285 Providing & Fixing of ISO certified company made Four Pole By pass Change Over Switch conforming to IS:13947(Part 3) : IEC:60947-3-1 and IEC:60947-6-1, Open execution type in the following ratings.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .100 A 286 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 0.5 A to 5 A rating 287 Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating 288 Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 289 50/63 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
23.
Drinking Water Supply and Sanitation #10236715 Price Bid
Augmentation Cum Reorganization Of Aapni Yojana Phase I Churu Bisau Feeder Water Supply Project Including 10 Years O And M District Churu.- 1 Part A : Cost Estimate For Pipeline Works 2 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 3 75 Mm Dia 4 90 Mm Dia 5 110 Mm Dia 6 125 Mm Dia 7 140 Mm Dia 8 160 Mm Dia 9 180 Mm Dia 10 200 Mm Dia 11 225 Mm Dia 12 100 Mm Dia 13 150 Mm Dia 14 200 Mm Dia 15 250 Mm Dia 16 300 Mm Dia 17 Providing, Lowering, Laying In Trenches, Aligning, Fixing In Position And Jointing Ductile Iron ( Di ) Isi Marked K-7 Grade S&S Pipes As Per 15:8329-2000 ( Amended Upto Date ) , With Internal Cement Mortar Lining Suitable For Potable Water With Rubber Ring ( Epdm ) Joints As Per Is: 5382- 1985 Including All Taxes ( Central And Local ) , Transportation And Freight Charges, Inspection Charges, Loading / I.I Unloading Charges, Including Cost Of Labour And Material, Specials ( Tee, Bend Etc. ) Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In Charge. ( Excluding Earth Work ) Note : Providing And Fixing Of All Requisite Specials As Per Drawing, Design And Layout Are Inclusive In Rm Measurement Of The Item And Shall Not Be Paid Separately. 18 100 Mm Dia 19 150 Mm Dia 20 200 Mm Dia 21 250 Mm Dia 22 300 Mm Dia 23 Providing, Lowering, Laying In Trenches, Aligning, Fixing In Position And Jointing Ductile Iron ( Di ) Isi Marked K-9 Grade S&S Pipes As Per 15:8329-2000 ( Amended Upto Date ) , With Internal Cement Mortar Lining Suitable For Potable Water With Rubber Ring ( Epdm ) Joints As Per Is: 5382- 1985 Including All Taxes ( Central And Local ) , Transportation And Freight Charges, Inspection Charges, Loading / I.I Unloading Charges, Including Cost Of Labour And Material, Specials ( Tee, Bend Etc. ) Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In Charge. ( Excluding Earth Work ) Note : Providing And Fixing Of All Requisite Specials As Per Drawing, Design And Layout Are Inclusive In Rm Measurement Of The Item And Shall Not Be Paid Separately. 24 150 Mm Dia 25 Providing, Lowering, Laying And Jointing In Trenches, Standard Lengths Hdpe Pe- 80 Pn-6 Isi Marked Pipes As Per Is-4984:1995 ( Ammended Upto Date ) With Neccessary Jointing Material Like Mechanical Connectors, I.E. Thread / Insert Joint / Quick Release Coupler Joint / Compression Fitting Joint Or Flanged Joint And Specials Jointing Pipe By Butt Fusion / Electro Fusion Welding Method, Including All Taxes, Transportation And Freight Charges, Inspection Charges, Loading / Unloading Charges, Stacking Of Pipes, Including Cost Of Labour And Material, Specials ( Tee, Bends Etc. ) , Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In-Charge Of Following Class And Diameter. ( Excluding Earthwork ) 26 75 Mm Dia 27 90 Mm Dia 28 110 Mm Dia 29 125 Mm Dia 30 140 Mm Dia 31 160 Mm Dia 32 180 Mm Dia 33 200 Mm Dia 34 225 Mm Dia 35 Providing, Lowering, Aligning, Fixing In Position And Jointing In Pipe Line, Combination Air Release Valve Kinetic Type With Single Chamber Housed Double Orifice And Have 3 Functions, Large Air Exhaust, Small Air Venting And Large Air Intake During Vacuum Of Pipeline Of Approved Makes Of Following Pressure Rating And Dia And As Per Following Specifications:Governing Standard - Awwa C512 , Body And Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865, Float & Internal Trim: Aisi 304 Stainless Steel, Seat Ring & Gasket - Epdm / Nbrdrilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Body & Coverinside And Outside Fasteners - Cs / Galvanised Steel , Outlet Of Big Orifice Will Have A Screen To Prevent Tamper Of Float, Big Orifice Size Should Be Equal Or Larger Than The Inlet Flange Bore, For Fully Comply With Awwa C512. ) , Valve Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer In Charge.Note: Rates Are Exclusive Of Connecting Tee, Pipe Piece And Earth Work. 36 50 Mm Dia 37 Construction Of Air Valve Pillar For Fixing Of Air Valves 38 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.0 / 1.6 39 100 Mm Dia 40 150 Mm Dia 41 200 Mm Dia 42 Providing, Lowering, Aligning, Fixingin Positionin Pipeline, Cid / Fsluicevalvesof Approved Make Of Following Pressure Rating & Dia Complete, Confirming To Is:14846 ( Amended Up To Date ) And Of Following Specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand Wheel Of Grey Cast Iron Of Is:210 / Fg200stem - Ss 304 , Body Seat Ring, Wedge Facing Ring & Bushes - Ltb2 / Ss, Face To Face Dimensions As Per Is 14846 / 2000 ( Amended Up To Date ) , All Exposed Machined Ferrous Surfaces Shall Be Painted With One Coat Of Aluminium Red Oxide Primer Conforming To Is:5660 And Two Coats Of Black Japan Paint Conforming Totype B Of Is 341Or Paint Conforming To Is9862 Or Is2932 ( Non-Toxic- Suitable For Drinking Water ) Applied Inside And Outside, Flanges Drilled As Per Is 1538.Nut-Bolt Confirming To Is:1363 And Is: 1367 / Cs / Galvanised Steel.Insersion Rubber Of Black Epdm 6Mm Thick . Suitablesupport Structure As Per Directions Of Eic. Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Manually Operated Ci Sluice Valves Of Class Pn 1.0 Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 43 80 Mm Dia 44 100 Mm Dia 45 125 Mm Dia 46 150 Mm Dia 47 200 Mm Dia 48 250 Mm Dia 49 300 Mm Dia 50 Cosntruction Of Valve Chamber For Sluice Valves, Flow Control Valve And Butterfly Valve As Per Approved Drawing And Specifications To The Satisfaction Of Engineer-In-Charge 51 Type - A ( 80 Mm To 100 Mm Dia ) 52 Type - B ( 125 Mm To 200 Mm Dia ) 53 Type - C ( 250 Mm To 350 Mm Dia ) 54 Construction Of Village Transfer Chamber As Per Approved Design, Drawing & Specification Given For Material Of Construction And Completion Of All Works Of Installation Of Sluice Valves, D.Joints, C.I. Pipes, Specials ( Excluding Supply ) Etc. Complete In All Respect To Achieve The Work As Given In The Scope Of Work. 55 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing Ci Dismantling Joint ( Suitable For Sluice Valves Etc. ) As Per Is Specifications Complete Of The Following Sizes Including All Jointing Material, Cost Of All Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. 56 100 Mm Dia 57 150 Mm Dia 58 200 Mm Dia 59 250 Mm Dia 60 300 Mm Dia 61 Construction And Commissioning Of Rcc Intze Type Over Head Service Reservoir Of Following Capacity And Staging As Per The Scope Of Work And Technical Specifications, Consisting Of The Following Main Activities: - 62 A ) Topographic Survey, Preparation Of Site Contour Plan, Conducting Sbc Testand Its Approval From Departmentbefore Construction. Submission And Approval Of Concrete Mix Design And Water Quality Test Report For Water To Be Used In Construction. B ) Excavation In All Types Of Soil, Pcc Below Foundation, All Rcc Work, Plinth Protection All Around The Structure Including All Material, Labour, Shuttering, Scaffolding Etc.C ) Ohsr Shall Be Provided With Adequate Plinth Protection All Around The Structure In A Width Starting From Edge Of Structure At Gl And Extending At Least Up To 1.0M Beyond The Edge Of Outer Most Projection Of Ohsr.The Plinth Protection Shall Consist Of 150Mm Thick Pcc In M-15 Grade Concrete Laid Over 150Mm Thick Layer Of Compacted Soil.D ) Providing And Applying Two Coats Of Food Grade Epoxy Paint On The Inside Surface On The Top Dome, Edge Beam And 600 Mm Height Of The Vertical Wall.E ) Conducting Successfully Hydro Test And Water Tightness Test As Per I.S. Code.F ) Providing And Applying Three Coats Of Anti-Carbonation Paint On The Top Surface Of The Top Dome.G ) Providing And Applying Three Coats Of Cement-Based Paint On The External Surface Of The Container, Balcony, Cone Wall, Columns & Beams Etc..H ) Providing And Fixing Ss-304 Ventilator, Ss 304 Manhole Frame And Cover And Ss-304 Ladder From Top Dome / Slab To Bottom Dome / Slab Inside Container. I ) Providing And Fixing Of Ms Section Ladder From The Last Landing To Balcony Having Railing All Around It And Ms Ladder With Safety Cage From Balcony To Top Dome / Slab.J ) Providing And Fixing Water Level Indicator ( Float Type ) . 63 K ) Providing And Fixing Of Hand Railing All Around The Balcony, Top Dome And Staircase Consisting Of 25Mm Diameter Class-B Gi Pipe In Two Rows And 1000 Mm High, 50X50x6mm Angle Iron Vertical Post At A Maximum Spacing Of 1500Mm Centres.L ) All Ms Parts To Be Painted With Two Coats Of The Enamel Paint Over The Primer Coat Of Red Oxide.M ) Providing And Fixing Of 150Mm Wide Pvc Water Bar For The Construction Joints In The Container ( Vertical Wall & Cone Wall ) .N ) Providing One Aluminium Portable Ladder Of Appropriate Length To Access First Landing ( 3.5 To 4.5M Above Gl ) From Ground.O ) Lighting Arrestor Consisting Of Providing And Fixing Of 2 Nos.Of Chemical Earthing And Connecting It To The Conical Cover Of Ss Ventilator With Two Separate Gi Strips Of 50Mmx3mm.P ) Ci / Di Puddle Collar Shall Be Fixed In The Bottom Dome / Slab For Connecting Inlet, Outlet, Overflow And Washout Pipe Of The Reservoir.Q ) Painting The Name Of The Scheme And Other Details On The Reservoir, And Any Other Work Related To Structure As Per The Directions Of Engineer-In- Charge, Technical Specification And Scope Of Work.R ) Inlet, Outlet, Overflow, Washout Pipes And Valves Are Not Included In This Work, Provision For The Same Shall Be Taken Separately. 64 Rates For Rcc Ohsr, Sbc 10 T / Sqm, Seismic Zone-Ii & Staging 18 M 65 100 Kl 66 150 Kl 67 Rates For Rcc Ohsr, Sbc 10 T / Sqm, Seismic Zone-Ii & Staging 20 M 68 100 Kl Each ( 100 X 2 Nos. ) 69 200 Kl Each ( 200 Kl X 3 Nos. ) 70 Providing And Fixing Double Flanged Isi Marked Di Class K-9 Pipes As Per Is:8329-2000 ( Amended Up To Date ) , As Vertical Pipes For Rcc Reservoirs Including Specials Required Such As Duck Foot Bend, Bend, Tee Etc. Providing Clamps At Every 3 Mtr, Jointing Materials Such As Nuts, Bolt, Rubber Packing, Hydraulic Testing Etc. Complete In All Respect Up To And From Valve Chamber As Per Direction Of Eic, Technical Specification And Scope Of Work. 71 100 Mm Dia 72 150 Mm Dia 73 200 Mm Dia 74 Construction Of Boundary Wall Of Brick / Stone Masonary As Per Enclosed Ga Drawing, Scope Of Work And Technical Specifications Complete Work In All Respect. Brief Details Of Boundary Wall Parameter Is As Below:1. Depth Of Foundation- 900 Mm.2. Pcc In M-10, Width -900 Mm And Thickness 100 Mm, 3. Section Of Foundation Above Pcc W-600 Mm, D-450Mm, W- 450Mm, D-450 Mm.4. Superstructure Work: Stone Masonary W-300, Height-1650 Mm, / Brick Work W-230 Mm, Height- 1650 Mm.5. Cement Mortar Pointing On Stone Masonary And Cement Mortar Plaster 20 Mm Thick On Brick Masonary In Cm 1:6.6. Expansion Joint Shall Be On Every 30 Mtr.7. On Top Of Wall There Shall Be Cc Coping 75 Mm Thick ( 1:2:4 ) Shall Be Provided.8. Pillar For Main Gate 350X350 Mm In Size Is Part Of Boundary Wall.9. Cement Paint Of Approved Colour In 3 Coat Shall Be Done. 75 Providing And Fixing Steel, Gate, Grating And Grills Made Of Angles, Tees, Square Bars, Flats Or Black Pipe With Hold Fast And Fitting Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide And Two Coat Of Enamal Paints. 76 Dismantling Of Cement Concrete Pavement For Pipe Lineand Chambers By Mechanical Means Using Pneumatic Tools, Cutting The Peripheral Edge By Cc Cutter, Breaking To Pieces Not Exceeding 0.02 Cum In Volume And Stock Piling At Designated Locations And Disposal Of Dismantled Materials Up To A Lead Of 1000 Meters. Measurement For Dismantled Trench To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shallbe Made For Trench Width More Than Specified, Re-Handling Of Material / Earth To Complete The Tasks As Per Technical Specification And Scope Of Work. 77 Providing And Laying In Position Cement Concrete M10 Grade Nominal Mix 1:4:8 ( 1 Cement : 4Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size ) In Base Course Complete Including All Material, Labour, Machinery, Lighting, Guarding For Road Restoration Work In Trenches Of Pipe Line And Chamber Work. Measurement For Cc Work To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Made Be Made For Trench Width More Than Specified, Complete Work As Per Technical Specification And Scope Of Work. 78 Providing And Laying In Position Cement Concrete In Specified Grade Over Prepared Base Course Complete Including Finishing, Curing, All Material, Labour, Machinery, Lighting, Guarding For Road Restoration Work In Trenches Of Pipe Line And Chamber Work. Measurement For Cc Work To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Made Be Made For Trench Width More Than Specified, Complete Work As Per Technical Specification And Scope Of Work. M20 Grade Nominal Mix1: 1.5: 3 ( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20Mm Nominal Size ) . 79 Dismantling Of Flexible Pavement For Pipe Lineand Chambers By Mechanical Means Using Pneumatic Tools, Breaking To Pieces Not Exceeding 0.02 Cum In Volume And Stock Piling At Designated Locations And Disposal Of Dismantled Materials Up To A Lead Of 1000 Meters. Measurement For Dismantled Trench To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Madefor Trench Width More Than Specified, Re-Handling Of Material / Earth To Complete The Tasks Per Technical Specification And Scope Of Work. 80 Bituminous Courses 81 Granular Courses 82 Provision For Restroration Of Bitumen Road After Laying & Jointing Pipe Line As Per Direction Of Engineer In Charge 83 Provision Forrestoration Of Wbm Road Cutting As Per Specifications. 84 Total Length Of Canal Corssing During Laying Of Pipe At Various Locations 85 Providing Service Connection As Per Technical Specification And Standard Drawing As Per Relevant Is Code ( Ammended Up To Date ) From All Kind Of Water Mains Up To Consumer Meter / Premises ( Complete Job ) . This Job Includes Digging Out Suitable Size Of Pits And Trench For Laying Service Line In All Kinds Of Soil Including Demolishing Of Cement Concrete, Wbm, Black Top Etc. Of All Thickness; Cutting Of Cc Road / Jhiri By Using A Concrete Cutter Machine; Depositing And Refilling Of Pit & Jhiri Watering And Ramming / Compacting In Layers And Disposal Of Surplus Excavated Soilas Directed With In A Lead Of 50 Meter; Providing And Fixing Of All Fitting Duty Approved In Accordance With Iso / Dtr 9080 As Per Specification For Portable Water Including Approved Make Of Ms / Pvc Clamp With Saddle Piece, Gunmetal Ferrule 4.0 Mm ( Isi Make ) , Valve ( Is: 778 ) And Specials With Mdpe Pipe Pe 80 Pn 12.5 As Per Iso 4424 Below Ground Level And P&F Gi Pipe 15 Mm Dia Class B ( Isi Mark ) Above Ground Level In The Premises For Fixing Tap ( Max. Length2.0 Mtr. ) , P&F A 15 Mm Bib Cork With Foam Flow Chrome Plated With Complete Brass Body Including Brass Handle Having Good Quality With Wt 300 To 325 Gm, Including Accessories With Flushing , Cleaning, Disinfecting And Testing Of Pipeline Complete Required For Making Of Service Connection Complete In All Respect Including Labour Charges. In Addition To The Ferrule, An Orrifice Of 4.0Mm Dia Should Also Be Provided In The Service Line At The Entry Pointy Of ConsumerS Property In Such A Way That It Should Be Accessible For Inspection To Vwsc, Phed And Any Other Authority Which Woyld Like To Inspect As And When Required. The Service Line Should Be Laid Atleast 45 Cm Below Ground Level, Except In Case Of Concrete / Bituminous Raods Where Minimum Depth Shall Be 20Cm. For Details Specifications Of Mdpe Pipes Please Refer Technical Specifications Of Bid Document. General Specifications Of Mdpe Pipes Shall Be As Under: The Raw Material Shall Be Virging Pe 80 Blue Compound And Comply With The Requirement Of Iso / Directive Of Testing Material : 9080 With Minimum Required Strength Of 8 Kg / Sq.Cm. ; The Raw Material Shall Be Food Grade Quality ; Ressure Rating Shall Be 12.5 Bar ; The Pipes Shall Bear Iso Marking 86 Removing& Re-Fixing Of Precast Concrete Interlocking Blocks By Manual, Stacking Of Serviciable & Non Serviceable Material Separately. Disposal Of Dismantled Material Lead Up To 50 Mtr. The C.C. Interlocking Paving Blocks Be Laid On Average 25 Mm Thick Bed Of Coarse Sand And The Joints To Be Filled With Fine Sand. Laying Procedure On Compacted Sub Base As Defined. Complete Job Is To Be Executed As Per The Directions Of Engineer In Charge. The Rates To Be Inclusive Of Fixing Of Minimum 70 Percent Reusable Precast Concrete Interlockingblock And Cost Of Required New Precast Concrete Interlocking Block Against Damaged, Including Alllead And Lift As Per Technical Specifications. ( Interlocking Blockmanufactured By Fully Computerized Automatic Stationery Hydraulic Vibro Pressed Machine & Full Computerized Automatic Batching Plant Of Class A-1 As Per Bs:6717-2001. Tensile Splitting Strength And Breaking Load As Per Bs: 6717-2001Colour: Grey Cement Natural Colour. Variation In Dimension : Less Than 1.6 Mm Variation In Thickness: Less Than 3.2 Mm ) 80 Mm Thick 87 Add Extra Over Item No 1.21 & 1.22 For Providing20 Mm Pe80 Pn 16 As Per Iso 4427 Mdpe Pipe Including Excavation, Providing, Laying & Jointing Of Service Line Above 5.00 Mtr. 88 Supply Laying And Pushing Of Ms Casing Pipe Of Specified Thickness Approved By Concerned Department Authority By Trenchless Method Adopting Any Suitable Technology Below Ground At Required Depth Under Running Traffic Condition As Per Highway / Railway Standard Including Carrying Out Survey Work At The Job Site For Determining Underground Cable Trenches Like Telephone, Cable, Water & Sanitary Lines And Resistivity Test For Finding The Soil Strata Using Necessary Equipments For Completion Of Works, Mobilizing Of Machineries And Specialized Crew At The Job Site Complete In All Respect, Including Excavation Of Driven Pit And Exit Pit ( Up To 3 Meter Depth ) With Proper Protection At These Sites With Shoring Sheets And Ismb. Providing Ms Cutting Edges For Front Shield And Constructing Thrust Bed At Designated Level. Necessary Dewatering And Providing Concrete Foundation At The Base Of The Driven Pit, Pvc / Rubber Saddle As Per The Requirement Of Highway / Railway Authority, Crane For Handing Of Pipe And Any Other Machinery, Tools, And Tackles Required, Construction Of Temporary Works As Per Design, Drawing And Method As Per Approved Byauthority Specification And The Direction Of The Engineer.Apply Corrosion, Resistant, Protection On Inside And Outside Of Casing Pipeas Per Technical Specification. 89 300 Mm Dia 8 Mm Thick Casing Pipe With Protective Coating. 90 Part B : Pump House & Cwr 91 Fabrication, Supply Of Flanged / Plain Ended Ms Pipe Made From Ms Sheet Strips Of Relevant Is Specification Of Approved Thickness By Welding, Lowering, Laying, Aligning, Fixing In Position At All Level / Depths In Trenches Complete Excluding Flanged Jointing Wherever ( Required ) Including All Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer. 92 Ms Pipe Upto 600 Mm Dia ( With Minimum 5Mm Thickness Sheet 93 Ms Pipe Above 600Mm Dia ( With Minimum 6.3Mm Thickness Sheet ) 94 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.0 / 1.6 95 100 Mm Dia 96 125 Mm Dia 97 150Mm Dia 98 200 Mm Dia 99 250 Mm Dia 100 300 Mm Dia 101 450 Mm Dia 102 500 Mm Dia 103 600 Mm Dia 104 700 Mm Dia 105 900 Mm Dia 106 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing Ci Dismantling Joint ( Suitable For Sluice Valves Etc. ) As Per Is Specifications Complete Of The Following Sizes Including All Jointing Material, Cost Of All Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. 107 100 Mm Dia 108 125 Mm Dia 109 150 Mm Dia 110 200 Mm Dia 111 250 Mm Dia 112 300 Mm Dia 113 450 Mm Dia 114 500 Mm Dia 115 600 Mm Dia 116 900 Mm Dia 117 1000 Mm Dia 118 Cosntruction Of Valve Chamber For Sluice And Butterfly Valves As Per Approved Drawing And Specifications To The Satisfaction Of Engineer-In-Charge 119 Valve Chamber ( 80 Mm To 100 Mm Dia ) 120 Valve Chamber ( 500 To 600 Mm ) 121 Providing, Lowering, Aligning, Fixing In Position In Pipe Line, Di D / F Resilient Seated ( Soft Seated ) Short Body Pattern Type Double Eccentric Butterfly Valves Of Approved Make Of Following Class & Dia Complete Confirming To Bs En 593 / Bs 5155 / Is 13095 / 1991 Amendedup To Date And Of Following Specifications: Body, Disc And End Cover Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Face To Face Dimensions As Per Din 3202 F4 / Is 13095Drilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Both Body And Disc Inside And Outside. Disc Seal Ring Of Epdm / Neoprene ( Food Grade Quality ) And Disc Seal Retaining Ring Of Ss / Cs. Shaft Of Ss- Aisi- 304 / 316 & Shaft Bearings-Bronze / Ptet Or Teflon With Epdm / Nbr O Ring Seal, Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic Including Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipeline As Per Technical Specification & As Per Direction Of Engineer-In-Charge.Class Pn 1.6, Motorised Operatednote: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 122 100 Mm Dia 123 150 Mm Dia 124 250 Mm Dia 125 450 Mm Dia 126 500 Mm Dia 127 600 Mm Dia 128 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing In Pipe Line, Di Dual Plate Check Valves Of Pn 1.6 Rating Of Following Dia ( Including Jointing And Jointing Material ) , Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. 129 100 Mm Dia 130 125 Mm Dia 131 150 Mm Dia 132 250 Mm Dia 133 450 Mm Dia 134 500 Mm Dia 135 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing In Pipe Line, Di Dual Plate Check Valves Of Pn 1.0 Rating Of Following Dia ( Including Jointing And Jointing Material ) , Including All Material, Labour, Testing And Commissioning As Per Technical Specificationsand As Per Direction Of Engineer. 136 600 Mm Dia 137 Providing And Fixingat Site With Necessary Packing, Horizontal Centrifugal Split Casting Pumps With 4 Poleinduction Motor As Per Is 12615: 2011 Or Amended Up To Date , Ci Casing And Casing Ring, Ss 316 Impeller, Ss 410 Shaft And Shaft Sleeve, Coupling Guard, Common Base Plate, Foundation Bolts, Cement Concrete Foundation Etc. Complete With All Respect As Per The Specification And Scope Of Work And Direction Of Engineer In Charge Of Following Range Of Duty Conditions.Note: Duty Condition Of Required Pump Shall Also Be Mentioned In Boq 138 295.08 Lps, 59 M Head 139 295.08 Lps, 80 M Head 140 274.12 Lps, 61 M Head 141 Providing And Fixingat Site With Necessary Packing, Horizontal Centrifugal Split Casting Pumps With 4 Poleinduction Motor As Per Is 12615: 2011 Or Amended Up To Date , Ci Casing And Casing Ring, Ss 316 Impeller, Ss 410 Shaft And Shaft Sleeve, Coupling Guard, Common Base Plate, Foundation Bolts, Cement Concrete Foundation Etc. Complete With All Respect As Per The Specification And Scope Of Work And Direction Of Engineer In Charge Of Following Range Of Duty Conditions.Note: Duty Condition Of Required Pump Shall Also Be Mentioned In Boq. 142 25.79 Lps, 70 M Head 143 26.83 Lps, 75 M Head 144 15.14 Lps, 79 M Head 145 Providing, Installation, Testing And Commissioning Of Centrifugal Monoblock Pump Set Conforming To Is 9079 Operating At Sync. Speed 2900 Rpm With Requisite Moc Impeller, Priming Funnel, Cock, Suitable Flanges At Suction And Delivery Side. Pump Shall Have Common Shaft For Pump And Motor. Motor Shall Be Suitable For Working On 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor Shall Be Tefc Type And Pump Set Shall Be Suitable For Working At Various Discharge And Head Requirements As Per Scope Of Work. Pump Shall Be Erected Onc.C. Foundation / Cross Channels / Rsj Frame Block With Suitable Foundation Bolts Grouted In C.C. Foundation Block Etc. Complete In All Respect As Perspecification, Scope Of Work And Direction Of Engineer In Charge Of Following Power Rating, Suitable For Prescribed Duty Conditions Mentioned In Td. 146 19.31 Lps, 41M Head 147 20.62 Lps, 54 M Head 148 9.93 Lps, 78 M Head 149 26.15 Lps, 44 M Head 150 18.46 Lps, 62 M Head 151 9.39 Lps, 73 M Head 152 Supplying, Erecting, Testing & Commissioning Of Electrically Operated Travelling Crane ( Eot ) .Main Girder & End Carriage Fabricated From Rollled Steel Section, Gear Box For All Motion, Electro Magnetic Friction Disc Type Brakes, All Safety Limit Switches, Lt Wheels En 9, Double Flanged 4No, With Sq. Cage Motor Of Adequate Rating ( Kw ) , Duly Painted Mechanical Cleaning And One Coat Of Primer And Two Coat Of Synthetic Paint And As Per The Direction Of The Engineer. 153 Span 7 M 6 Mtr. Lift 154 Providing, Lowering, Aligning, Fixing In Position In Pipe Line, Ci D / F Sluice Valves Of Approved Make Of Following Pressure Rating & Dia Complete, Confirming To Is:14846 ( Amended Up To Date ) And Of Following Specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand Wheel Of Grey Cast Iron Of Is:210 / Fg200 Stem - Ss 304 , Body Seat Ring, Wedge Facing Ring & Bushes - Ltb2 / Ss , Face To Face Dimensions As Per Is 14846 / 2000 ( Amended Up To Date ) , All Exposed Machined Ferrous Surfaces Shall Be Painted With One Coat Of Aluminium Red Oxide Primer Conforming To Is:5660 And Two Coats Of Black Japan Paint Conforming Totype B Of Is 341Or Paint Conforming To Is9862 Or Is2932 ( Non-Toxicsuitable For Drinking Water ) Applied Inside And Outside, Flanges Drilled As Per Is 1538.Nut-Bolt Confirming To Is:1363 And Is: 1367 / Cs / Galvanised Steel.Insersion Rubber Of Black Epdm 6Mm Thick . Suitable Support Structure As Per Directions Of Eic. Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-Incharge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Ci Sluice Valve Of Class Pn-1.0 155 100 Mm Dia 156 600 Mm Dia 157 Providing And Fixing Double Flanged Isi Marked Di Class K-9 Pipes As Per Is:8329-2000 ( Amended Up To Date ) , As Vertical Pipes For Rcc Reservoirs Including Specials Required Such As Duck Foot Bend, Bend, Tee Etc. Providing Clamps At Every 3 Mtr, Jointing Materials Such As Nuts, Bolt, Rubber Packing, Hydraulic Testing Etc. Complete In All Respect Up To And From Valve Chamber As Per Direction Of Eic, Technical Specification And Scope Of Work. 158 100 Mm Dia 159 600 Mm Dia 160 700 Mm Dia 161 Design & Construction Of Clear Water Reservoirs Of Required Capacity At Following Places, Including Its Piping, Fittings, Etc Complete In All Respect As Per The Scope Of Work & Specifications Given In The Tender Document At The Following Places & Sizes . 162 Tps / Cps Bhaleri 163 Design, Manufacturing And Supply Of Batch Type Electro Chlorinator Of Capacity As Per Requirement Of Site 164 Part : C Repair Works 165 Repair Of Valves From Karamsana To Bhaleri 166 Providing, Lowering, Aligning, Fixing In Position And Jointing In Pipe Line, Di Body Flanged End Tamper Proofkinetic Air Valve Of Approved Makes Of Following Pressure Rating And Dia And As Per Following Specifications: Governing Standard - Awwa C512 / Is:14845:2000 ( Amended Up To Date ) Body, High Pressure Cover , Low Pressure Cover, Cowl Andjoint Support Ring - Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865, Float- Lp Ball & Hp Ball : Aisi 304 Stainless Steel, Seat Ring & Gasket - Epdm / Nbr , Hp Orifice & Hp Orifice Plug : Bronze / Ss , Bush: Bronze , Flanges As Per Is / Bs, Drilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Body & Coverinside And Outside .Fasteners - Cs / Galvanised Steel, Outlet Of Big Orifice Will Have A Screen To Prevent Tamper Of Float, With Di Metal Seated D / F Non Rising Stem. Sluice Valves As Per ( Is: 14846 Amendedupto Date ) Pn 1.6 Ratings. Valves Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer In Charge. Note: Rates Are Exclusive Of Connecting Tee, Pipe Piece And Earth Work. ( Class Pn 1.6 ) 167 150 Mm Dia 168 200 Mm Dia 169 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 170 Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.0 / 1.6Sectional Valves 171 150 Mm Dia 172 200 Mm Dia 173 900 Mm Dia With Gear 174 Providing, Lowering, Aligning, Fixing In Position And Jointing Ms Dismantling Joint Fabricated Steel ( Suitable For Sluice Valves Etc. ) As Per Is Specificationscompleteofthefollowingsizesincludingall Jointing Material, Costofalllabour, Testingandcommissioningand As Per Technical Specifications And Direction Of Engineer In-Charge. Class Pn 1.0 / 1.6 175 900 Mm Dia 176 Construction Of Valve Chamber As Per Approved Drawing And Specification Of Engineer In Charge 177 Type G Size Up To 800Mm To 900 Mm 178 Major Repair Of Pmc Office Building, Residential Buildings At Pmc Campus, All Work Civil, Electric, Water Supply, Road, Drainage Cleaning, Horticulture, Etc. Complete 179 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 180 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 181 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 182 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 183 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 184 Repair To Brick Masonary In Cement Sand Mortar With Taking Out Of Deceayed From Wall And Replaceing With New Briks.Cement Sand Mortar 1:6. With New Brick. 185 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 186 Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. 187 Cutting Jhiri Above 75Mmx75mm And Below 150X150 Mm Etc. And Making Good. 188 Scraping Old Surface And Redoing Lime Loi Or Sandla. 189 Renewing Glass Panes, With Puty And Nails Wherever Necessary: 190 5.5 Mm Thick Plain Glass Panes. 191 Renewing Glass Panes With Wooden Fillets Wherever Necessary: 192 5.5 Mm Thick Plain Glass Panes. 193 Providing And Fixing 16 Mm M.S. Fan Clamps Of Standard Shape And Size In R.C.C. Slab / Stone Slab Roofing Including Cutting Chase And Making Good And Painting Exposed Portion Of The Clamps Complete: 194 In Existing Roof. 195 Guniting Damaged R.C.C. Slab, Beams And Columns For Strengthening With Cement Sand Mortar 1:2 ( 1-Cement:2-Sand ) Including Preparing The Surface, Making V Shaped Joints, Cleaning The Reinforcement Bars With Jet Of Potable Water And Drying With Compressed Air, Including Cost Of Centering And Shuttering And Finishing To Match The Existing Surface Etc. Complete, Including Provided M.S. Welded Mesh To Gauge 25 Mm X 25 Mm Framing With Average Thickness Of 25 Mm. 196 Chopping Loose And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Blasting, Clening With A Jet Of Water / Air As Necessary And Getting It Dried With Compressed Air Including All Scaffolding: 197 Depth 50 Mm To 75 Mm. 198 Depth 75 Mm To 100 Mm. 199 Repairofdoor, Windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : 200 Style / Rail Of Teak Wood 30Mm Thick / Aluminium Section 201 4Wide 202 6 Wide 203 Panel By 204 Shuttering Ply - 9Mm Thick ( Commercial ) 205 Wire Gauge 14 Mesh X 24 Gauge 206 Plain Glass Panes 4Mm Thick 207 Aldrop Of Mild Steel 208 12 Long X12mm Dia 209 8 Long X 10Mm Dia 210 Stopper Of Aluminium With 211 Single Rubber Gutka 212 Double Rubber Gutka 213 Door Springs Of Mild Steel 214 Steel Hinges 215 For Wooden Chowkhat 3 Size. 216 For Wooden Chowkhat 4 Size 217 For Stone Chowkhat , 4Size 218 Mild Steel Tower Bolt 6 Long 219 Steel Locking Bolt 220 Steel Handle 6 Size 221 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 222 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 223 M10 Grade Nominal Mix 1: 3: 6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stoneaggregate 20Mm Nominal Size ) . 224 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggre -Gate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth. 225 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. M20 Grade Nominal Mix / Design Mix 226 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For : 227 Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands , Coping, Bed Plates, Anchor Blocks, Sills, Chhajjas Lintel, Beam Etc. 228 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. 229 Hot Rolled Deformed Bars ( Is : 1139 ) . 230 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 231 20 Mm Thick. 232 Providing And Fixing Expanded Metal Mesh Of Size 20X60 Mm And Strands 3.5 Mm Vide 1.6 Mm Thick Weighing 3.64 Kg. Per Sqm. For Encasing Ofrolledsteel Sections In Beams, Columns And Grillages Excluding Cost Of Hangers. 233 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 234 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 235 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Fivelevelusing F.P.S. Bricks Of Designation 75 236 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 237 Brick Work In Partition In Super Structure Upto Five Storey 7Cm. Thick ( Brick On Edges ) Using F.P.S. Bricksof Class Designation 75 In : 238 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 239 Supplying And Fixing Machine Cut And Polished Stone Shelves, Tands And Sills In Cm 1:3 With Machine Cut Edges: 240 Sand Or Other Approved Stone 25 Mm Thick. 241 Sand Or Other Approved Stone 35 Mm Thick. 242 Sand Or Other Approved Stone 50 Mm Thick. 243 Kota Stone 25 To 30 Mm Thick. 244 Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills, Counters. Floors Etc. Laid On 12Mm ( Av. ) Thick Base Of Cement Mortar 1:3 Jointing With White Cement Mortar 1:2 ( 1 White Cement: 2 Marble Dust ) With Pigment To Match The Shade Of The Marble Slab Complete Including Grinding, Rubbing And Polishing Of: 245 Jhunjhunu / Jalore ( Red / Choclate Colour ) 246 Above 3601 Cm2 Slabs 247 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption’S Less Than 0.08% And Conforming To Is : 15622 Of Approved Make In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. 248 Size Of Tile 60X60 Cm 249 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 250 Category - I : Kajariya, Jhonson, Orient, Somani Make Etc. 251 Providing & Fixing In Cement Sand Mortar 1:4 Single Paitam ( Rebated ) Stone Doors Windows And Ventilator Frames Of Approved Quarry : 252 Size 100X75mm. 253 Size 125X100mm. 254 Providing And Fixing In Cm 1:4 Double Paitam ( Rebated ) Stone Door Window And Ventilator Frames Of Approved Quarry : 255 Size 125 X 100Mm. 256 Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal, Dehydreresin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure ‘A’ 257 30 Mm Thick Shutter 258 Commercial Veneer Both Side 259 Decorative Teakveneer One Side 260 Providing And Fixing Fully Paneled Double Leaf Shutter For Doors As Per Approved Design And Drawing With Approved Ordinary C.P. / Oxidized Steel Fittings As Per Annexure – A’ And Width Of Styles & Top Rails Of 100Mm And Lock Rails Width Of 150Mm And Bottom Rails Of 200Mm Width Including Teak Wood Beading Of Size 19Mmx12mm On Both Faces Complete : 261 30 Mm Thick Ghana Teak Wood Grade - I 262 Wire Gauge 24 Gauge 14 Mesh Of Is Designation 85 Gauge Wires Of Dia 0.56 Mm Panels 263 Demolishing Cement Concrete Including Disposal Of Material Within 50 Meter Lead : 264 1:3:6 Or Richer Mix. 265 Demolishing Of R.C.C. Work Including Stacking Of Steel Bars And Disposal Of Unserviceab Le Material Within 50 Meters Lead. 266 Demolishingbrickwork Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead. 267 In Cement Mortar. 268 Structural Steel Work In Single Section Fixed With Or Without Connecting Plate Including Cutting, Hoisting ( Height Upto 10 M ) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. 269 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded With 15X3 Mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. 270 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 271 Providing & Fixing Ms Sheet Single Leaf Door Shutters In Angle Iron Frame 35X35x5 Mm Suitablly Diagonally Braced With 25X3mm Flat Ironabove And Below Lock Rail Of Size 50X5 Mm Beading Extra Includingall Fittings, As Per Direction Of Engg. Incharge But Excluding Coes Of Chokhats Including Two Coats Of Anti Corrastie Red Oxide Primer Panit. 272 Ms Sheet 18 Swg 273 Providing & Fixing Steel Glazed Doors, Windows And Ventilators With Shutters Of Standred Rolled Steel Section Joint Mitred And Welded With Steel 13X3mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required, Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Copper Glazing Clips And Special Metal-Sash Putty Of Approved Make, Or Metal Beading With Screws Complete Including Priming Coat Of Approved Steel Primer, Excluding The Cost Of Metal Beading And Other Fittings Except Necessary Hinges Of Pivots Steel Handles And Peg Stay Etc. As Required. 274 Patially Fixed And Partially Openable Fixed Area Not Exceed 33% 275 Supplying And Fixing Fixed Wire Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 276 14 Mesh X 24 Gauge 277 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 278 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 279 Distempering With Dry Distemper Of Approved Brand And Shade ( Two Or More Coats ) And Of Required Shade On New Work, Over And Including, Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 280 Providing & Fixing 12 Mm Thick Tegular Edge Glass Fibre Reinforced Gypsum False Ceiling Tiles Of Size 595 X 595 Mm In True Horizontal Level Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanised Steel Sections ( Galvanized @ 170 Gsm / Sqm. ) Consisting Of Main “T” Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38mm Made From 0.30Mm Thick ( Minimum ) Sheet Spaced At 1200Mm Center To Center And Cross “T” Of Size 24X25mm Made Of 0.30Mm Thick ( Minimum ) Sheet, 1200Mm Long Spaced Between Main “T” At 600Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross “T” Of Length 600Mm And Size 24X25mm Made Of 0.30 Mm Thick ( Minimum ) Sheet To Be Interlocked At Middle Of The 1200X600mm Panel To Form Grids Of 600X600mm And Wall Angle Of Size 21X21x0.30 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Wherever, Required, Cutting / Making, Opening For Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main “T” Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Fixed To Ceiling With 6 Mm Dia And 50Mm Long Dash Fasteners, 4Mm Gi Adjustable Rods With Galvanised Level Clips Spaced At 1200Mm Center To Center Along Main T, Bottom Exposed Width Of 24Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete At All Heights As Per Specifications Drawings And As Directed By Engineer-In-Charge. 281 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 282 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 283 Old Work ( One Or More Coats ) . 284 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 285 Two Or More Coats On New Work. 286 One Or More Coats On Old Work. 287 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 288 For Area Of Each Slab Up To 900 Sq. Cm 289 For Area Of Each Slab Up To 901 To 2000Sq. Cm 25 Mm Thick Slab. 290 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 291 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 292 Add 10 % For Water Supply And Sainatry Works 293 Add 10 % For Electric Works 294 Horticulture 295 Cutting Of Trees, Including Cutting Of Trunks, Branches And Removal Of Stumps, Roots, Stacking Of Serviceable Material With All Lifts And Up To A Lead Of 1000 Mtrs And Earth Filling In The Depression / Pit To Required Compaction As Per Mort&H Specification Clause 201. ( Measurment Of Girth To Be Done At Height Of 1 M Above Ground Level ) 296 Girth From 300 Mm To 600 Mm 297 Clearing Grass And Removal Of Rubbish ( Maximum 150Mm ) By Manual Means And Disposal At A Lead Of 50 Metres As Per Mort&H Specification Clause 201. 298 Supply Of Dry Manure Including Loading Unloading, Transportation & Stacking At Site. 299 From Yard Manure ( Organic ) 300 Compost 301 Goat Dungmanure 302 Supply & Stacking Good Earth At Site Complete Including Loading Unloading & Transporation Etc. 303 Supply Of Insecticides & Pesticides At Store In Dust / Liquid Form Complete 304 Methly Prathion 2% 305 Supply Of Different Varities Of Tree / Shrubs / Climbers According To Height And Age Of The Plant At Site Including Loading / Unloading & Transportation Etc. Complete: 306 Different Flowing Plants 900 Mm To 1500 Mm 307 Different Varrities Of Shrubs 600 Mm To 900 Mm 308 Different Varrities Of Climbers 900 Mm To 1500 Mm 309 Laying Of Lawns Including Ploughing Levelling Breaking Of Clods Manuring & Removal Of Stones Etc. ( Cost Of Manure Of Extra Good Earth To Be Paid Seperatley ) Maintenance Of Lawns For 30 Days Of More Till The Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing In The Duration Of Planting If Lawn Die Some Where The Contractor Will Replant It At His Own Cost. 310 In Rows 7.5 Cms. Apart In Either Direction 311 Renovating Lawns Including Weeding Cheeling The Grass Forking The Ground Top Dressing With Manure. Mixing The Same With Forked Soil Watering Maintaing The Lawns For 30 Days Or More Till Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing & Disposal Of Rubbish As Directed. 312 Road And Drainage Work 313 Providing, Laying, Spreading And Compacting Of Granular Sub-Base By Providing Close Graded Material ( Table 400-1 ) , Spreading In Uniform Layers With Motor Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Vibratory Roller To Achieve The Desired Density, Complete As Per Mort&H Specification Clause - 401 Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 314 Grading - Ii Material 315 Providing Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes As Per Table 400-7 To Water Bound Macadam Specification Including Spreading In Uniform Thickness; Hand Packing, Rolling With Power Roller 8-10 Tonnes, In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening ( Table 400-8 ) Binding Materials To Fill Up The Interstices Of Coarse Aggregates, Watering ( With Water Browser ) And Compacting To Required Density, Making Necessary Earthen Bund To Protect Edges As Per Clause 404 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion Complete 316 Crusher Broken -Grade-Ii ( 63-45Mm ) 317 Providing And Applying Primer Coat Over Prepared Surface Of Granular Base With Bitumen Emulsion As Per Is : 8887 And Approved Quality @ 0.6 Kg / Sqm With The Help Of Spray Set Fitted On Bitumen Container ( Boiler ) After Cleaning The Surface Including Removing Of Binding Material And Other Foreign Matter With Wire Brushes And Small Picks, Sweeping With Brooms Or Soft Brushes And Finally Dusting With Old Gunny Bags And Compressed Air To Receive Bituminous Treatment Complete As Per Clause 502 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 318 Providing And Laying Open Graded Premix Carpet 20Mm Thick ( Compacted ) , On Prepared Surface In A Single Course As Wearing Course, Composed Of Specified Graded Crushed Stone Aggregate As Per Table 500-23, Premixed With Bituminous Binder @ 14.60 Kg / 10Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) , Including Loading Of Material With F.E. Loader, Hot Mixing Of Stone Aggregate And Bitumen In Computerised Hot Mix Plant, Transporting The Mixed Material By Tippers To Paver And Laying With Paver Finisher Fitted With Electronic Sensor Control To The Required Level And Grade, Compacting Smooth Wheeled Roller 8-10 Tonne Capacity And Finishing To Required Level To Achieve The Desired Density As Per Clause 511 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion But Excluding Cost Of Tack Coat / Seal Coat. 319 With Bitumen Vg-Grade 30 320 Providing And Applying Premixed Seal Coat Type B Comprising Of Thin Application Of Fine Aggregate 0.06 Cum / 10 Sqm Premix With Bitumen Binder @ 6.8 Kg / 10 Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) Laying With Paver Finisher With Electronic Sensor Control And Rolling With Power Roller 8-10 Tonne Complete As Per Clause 513 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 321 With Bitumen Vg-Grade 30 322 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 323 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 324 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 325 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 326 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 327 Providing And Laying Reinforced Cement Concrete Pipe Np4 / Prestrssed Concrete Pipe For Culverts Including Jointing Ends And Fixing Collar With Cement Mortar 1:2 Complete As Per Clause 1000 & 2900 Of Mort&H Specification Including All Material, Labour Form Work, Machinery. 328 200 Mm Internal Diameter 329 Providing And Fixing Of Reinforced Ferro-Cement Drain Covers Designed For A Class Loading Duly Marked On Cover With Adequate Steel Reinforcement Having Thickness 75Mm To 150Mm Anti Corrosive Bitumen Painted M.S. Plate , Rim And M.S. Lifting Hooks, Admixtures Like Plasticizer, Bond Improving Compound, Shrinkage, Resistance Compound, Abrasion Resistant Complete As Per Approved Design Etc 330 Standard Size 600X800mm ( 75Mm Thick ) For Span 300 To 450Mm 331 Providing And Laying Lean Cement Concrete 1:4:8 In Sub- Base Over A Prepared Sub-Grade With Coarse And Fine Aggregate Conforming To Is: 383, The Size Of Coarse Aggregate Not Exceeding 25 Mm, Aggregate Cement Ratio Not To Exceed 15:1, Aggregate Gradation After Blending To Be As Per Table 600-1, Cement Content Not To Be Less Than 150 Kg / Cum, Optimum Moisture Content To Be Determined During Trial Length Construction, Concrete Strength Not To Be Less Than 10 Mpa At 7 Days, Mixed In A Batching Plant, Transported To Site, Laid With A Paver With Electronic Sensor, Compacting With 8-10 Tonnes Vibratory Roller, Finishing And Curing Complete As Per Clause 601, 112 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion 332 Providing And Laying Un-Reinforced, Plain Cement Concrete Mix With Concrete Mixer & Vibrator Pavement Over A Prepared Sub Base With 43 Grade Cement , Coarse And Fine Aggregate Conforming To Is: 383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed As Per Approved Mix Design, Laid, Spread, Compacted And Finished In A Continuous Operation Including Provision Of Contraction, Expansion, Construction And Longitudinal Joints Etc Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 333 Pcc M-30 334 Campus Lighting 335 Supply And Erection Of Octagonal Pole Of Following Length And Dimension As Per Table-3 With Base Plate On The Cement Concrete Foundation Of M-15 / M-20 Grade ( 1:1.5:3 ) With The Help Of Anchor Bolts Of Grade 6.8 ( Is 1367 P Iii ) . The Pole Shall Be Made Of S-355Jo Grade Steel Sheet , Folded Lengthwise To Obtained Octagonal Shape, Having Single Longitudinal Seam Weld And Hot Dipped Galvanised Internally & Externally In Accordance With Is 2629. The Pole Shall Have A Weatherproof Flush Door And Locking Arrangements. The Complete Work Shall Be Supervised And Certified By The Manufacturers For Satisfactory Supply, Erection, Testing And Commissioning. 336 7 Mtr 337 Supply, Erection And Fixing Of Hot Dipped Galvanised Overhang ( 60 X 3.25 Mm ) With Cap ( 250 X 137.9 X 4.05 Mm ) Over The Existing Poles 338 Single Arm Overhang 339 P & F Of Ip 65 / 67 Protected Led Flood Light System With Aluminium Housing, 3 X 1W, 220V, 50Hz Led Lamps With Dynamic Color Changing Capability Available In Quick Connecting Cable Coupled With Various Mounting Accessories. Ability To Create 16.7 Million Uniform, Smooth And Brilliant Colors Without Revealing Any Lamp Image. Available In 5 Colors – Amber, Green, Blue, Red And White. 340 Providing & Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Makein Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Underlayer Ofsand, Second Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size 341 10.0 Sq.Mm2 Cor 342 Add 5% Over Head 343 Repair Of Pump House Building At Churu, Bhaleri Like Repair Of Plaster, Floor, Roof, Doors, Windows, Colour Washing, Painting Etc. 344 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 345 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 346 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 347 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 348 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 349 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 350 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 351 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 352 Scraping Old Surface And Redoing Lime Loi Or Sandla. 353 Patch Repair To Cement Concrete Floor Including Digging Out Old Floor In Regular Shape And Removal Of Rubbish Curing Etc. Complete In All Respects. 354 Renewing Glass Panes, With Puty And Nails Wherever Necessary: 355 5.5 Mm Thick Plain Glass Panes. 356 Providing And Fixing 16 Mm M.S. Fan Clamps Of Standard Shape And Size In R.C.C. Slab / Stone Slab Roofing Including Cutting Chase And Making Good And Painting Exposed Portion Of The Clamps Complete: 357 In Existing Roof. 358 Chopping Loose And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Blasting, Clening With A Jet Of Water / Air As Necessary And Getting It Dried With Compressed Air Including All Scaffolding: 359 Depth 50 Mm To 75 Mm. 360 Depth 75 Mm To 100 Mm. 361 Repairofdoor, Windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : 362 Style / Rail Of Teak Wood 30Mm Thick / Aluminium Section 363 4Wide 364 6 Wide 365 Panel By 366 Shuttering Ply - 9Mm Thick ( Commercial ) 367 Wire Gauge 14 Mesh X 24 Gauge 368 Plain Glass Panes 4Mm Thick 369 Aldrop Of Mild Steel 370 12 Long X12mm Dia 371 8 Long X 10Mm Dia 372 Stopper Of Aluminium With 373 Single Rubber Gutka 374 Double Rubber Gutka 375 Door Springs Of Mild Steel 376 Steel Hinges 377 For Wooden Chowkhat 3 Size. 378 For Wooden Chowkhat 4 Size 379 For Stone Chowkhat , 4Size 380 Mild Steel Tower Bolt 6 Long 381 Steel Locking Bolt 382 Steel Handle 6 Size 383 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 384 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 385 M10 Grade Nominal Mix 1: 3: 6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stoneaggregate 20Mm Nominal Size ) . 386 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggre -Gate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth. 387 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. M20 Grade Nominal Mix / Design Mix 388 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For : 389 Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands , Coping, Bed Plates, Anchor Blocks, Sills, Chhajjas Lintel, Beam Etc. 390 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. 391 Hot Rolled Deformed Bars ( Is : 1139 ) . 392 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 393 20 Mm Thick. 394 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 395 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 396 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Fivelevelusing F.P.S. Bricks Of Designation 75 397 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 398 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 399 Category - I : Kajariya, Jhonson, Orient, Somani Make Etc. 400 Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal, Dehydreresin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure ‘A’ 401 30 Mm Thick Shutter 402 Commercial Veneer Both Side 403 Providing And Fixing Fully Paneled Double Leaf Shutter For Doors As Per Approved Design And Drawing With Approved Ordinary C.P. / Oxidized Steel Fittings As Per Annexure – A’ And Width Of Styles & Top Rails Of 100Mm And Lock Rails Width Of 150Mm And Bottom Rails Of 200Mm Width Including Teak Wood Beading Of Size 19Mmx12mm On Both Faces Complete : 404 30 Mm Thick Ghana Teak Wood Grade - I 405 Wire Gauge 24 Gauge 14 Mesh Of Is Designation 85 Gauge Wires Of Dia 0.56 Mm Panels 406 Demolishing Cement Concrete Including Disposal Of Material Within 50 Meter Lead : 407 1:3:6 Or Richer Mix. 408 Demolishing Of R.C.C. Work Including Stacking Of Steel Bars And Disposal Of Unserviceab Le Material Within 50 Meters Lead. 409 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 410 Providing & Fixing Ms Sheet Single Leaf Door Shutters In Angle Iron Frame 35X35x5 Mm Suitablly Diagonally Braced With 25X3mm Flat Ironabove And Below Lock Rail Of Size 50X5 Mm Beading Extra Includingall Fittings, As Per Direction Of Engg. Incharge But Excluding Coes Of Chokhats Including Two Coats Of Anti Corrastie Red Oxide Primer Panit. 411 Ms Sheet 18 Swg 412 Providing & Fixing Steel Glazed Doors, Windows And Ventilators With Shutters Of Standred Rolled Steel Section Joint Mitred And Welded With Steel 13X3mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required, Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Copper Glazing Clips And Special Metal-Sash Putty Of Approved Make, Or Metal Beading With Screws Complete Including Priming Coat Of Approved Steel Primer, Excluding The Cost Of Metal Beading And Other Fittings Except Necessary Hinges Of Pivots Steel Handles And Peg Stay Etc. As Required. 413 Patially Fixed And Partially Openable Fixed Area Not Exceed 33% 414 Supplying And Fixing Fixed Wire Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 415 14 Mesh X 24 Gauge 416 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 417 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 418 Distempering With Dry Distemper Of Approved Brand And Shade ( Two Or More Coats ) And Of Required Shade On New Work, Over And Including, Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 419 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 420 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 421 Old Work ( One Or More Coats ) . 422 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 423 Two Or More Coats On New Work. 424 One Or More Coats On Old Work. 425 Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete. 426 40 Mm Thick With 20 Mm Thick Nominal Size Aggregate. 427 75 Mm Thick With 20 Mm Thick Nominal Size Aggregate. 428 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 429 For Area Of Each Slab Up To 900 Sq. Cm 430 For Area Of Each Slab Up To 901 To 2000Sq. Cm 25 Mm Thick Slab. 431 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 432 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 433 Add 5 % For Water Supply And Sainatry Works 434 Add 10 % For Electric Works 435 Horticulture 436 Cutting Of Trees, Including Cutting Of Trunks, Branches And Removal Of Stumps, Roots, Stacking Of Serviceable Material With All Lifts And Up To A Lead Of 1000 Mtrs And Earth Filling In The Depression / Pit To Required Compaction As Per Mort&H Specification Clause 201. ( Measurment Of Girth To Be Done At Height Of 1 M Above Ground Level ) 437 Girth From 300 Mm To 600 Mm 438 Clearing Grass And Removal Of Rubbish ( Maximum 150Mm ) By Manual Means And Disposal At A Lead Of 50 Metres As Per Mort&H Specification Clause 201. 439 Supply Of Dry Manure Including Loading Unloading, Transportation & Stacking At Site. 440 From Yard Manure ( Organic ) 441 Compost 442 Goat Dungmanure 443 Supply & Stacking Good Earth At Site Complete Including Loading Unloading & Transporation Etc. 444 Supply Of Insecticides & Pesticides At Store In Dust / Liquid Form Complete 445 Methly Prathion 2% 446 Supply Of Different Varities Of Tree / Shrubs / Climbers According To Height And Age Of The Plant At Site Including Loading / Unloading & Transportation Etc. Complete: 447 Different Flowing Plants 900 Mm To 1500 Mm 448 Different Varrities Of Shrubs 600 Mm To 900 Mm 449 Different Varrities Of Climbers 900 Mm To 1500 Mm 450 Laying Of Lawns Including Ploughing Levelling Breaking Of Clods Manuring & Removal Of Stones Etc. ( Cost Of Manure Of Extra Good Earth To Be Paid Seperatley ) Maintenance Of Lawns For 30 Days Of More Till The Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing In The Duration Of Planting If Lawn Die Some Where The Contractor Will Replant It At His Own Cost. 451 In Rows 7.5 Cms. Apart In Either Direction 452 Renovating Lawns Including Weeding Cheeling The Grass Forking The Ground Top Dressing With Manure. Mixing The Same With Forked Soil Watering Maintaing The Lawns For 30 Days Or More Till Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing & Disposal Of Rubbish As Directed. 453 Road And Drainage Work 454 Providing, Laying, Spreading And Compacting Of Granular Sub-Base By Providing Close Graded Material ( Table 400-1 ) , Spreading In Uniform Layers With Motor Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Vibratory Roller To Achieve The Desired Density, Complete As Per Mort&H Specification Clause - 401 Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 455 Grading - Ii Material 456 Providing Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes As Per Table 400-7 To Water Bound Macadam Specification Including Spreading In Uniform Thickness; Hand Packing, Rolling With Power Roller 8-10 Tonnes, In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening ( Table 400-8 ) Binding Materials To Fill Up The Interstices Of Coarse Aggregates, Watering ( With Water Browser ) And Compacting To Required Density, Making Necessary Earthen Bund To Protect Edges As Per Clause 404 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion Complete 457 Crusher Broken -Grade-Ii ( 63-45Mm ) 458 Providing And Applying Primer Coat Over Prepared Surface Of Granular Base With Bitumen Emulsion As Per Is : 8887 And Approved Quality @ 0.6 Kg / Sqm With The Help Of Spray Set Fitted On Bitumen Container ( Boiler ) After Cleaning The Surface Including Removing Of Binding Material And Other Foreign Matter With Wire Brushes And Small Picks, Sweeping With Brooms Or Soft Brushes And Finally Dusting With Old Gunny Bags And Compressed Air To Receive Bituminous Treatment Complete As Per Clause 502 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 459 Providing And Laying Open Graded Premix Carpet 20Mm Thick ( Compacted ) , On Prepared Surface In A Single Course As Wearing Course, Composed Of Specified Graded Crushed Stone Aggregate As Per Table 500-23, Premixed With Bituminous Binder @ 14.60 Kg / 10Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) , Including Loading Of Material With F.E. Loader, Hot Mixing Of Stone Aggregate And Bitumen In Computerised Hot Mix Plant, Transporting The Mixed Material By Tippers To Paver And Laying With Paver Finisher Fitted With Electronic Sensor Control To The Required Level And Grade, Compacting Smooth Wheeled Roller 8-10 Tonne Capacity And Finishing To Required Level To Achieve The Desired Density As Per Clause 511 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion But Excluding Cost Of Tack Coat / Seal Coat. 460 With Bitumen Vg-Grade 30 461 Providing And Applying Premixed Seal Coat Type B Comprising Of Thin Application Of Fine Aggregate 0.06 Cum / 10 Sqm Premix With Bitumen Binder @ 6.8 Kg / 10 Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) Laying With Paver Finisher With Electronic Sensor Control And Rolling With Power Roller 8-10 Tonne Complete As Per Clause 513 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 462 With Bitumen Vg-Grade 30 463 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 464 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 465 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 466 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 467 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 468 Providing And Laying Reinforced Cement Concrete Pipe Np4 / Prestrssed Concrete Pipe For Culverts Including Jointing Ends And Fixing Collar With Cement Mortar 1:2 Complete As Per Clause 1000 & 2900 Of Mort&H Specification Including All Material, Labour Form Work, Machinery. 469 200 Mm Internal Diameter 470 Providing And Fixing Of Reinforced Ferro-Cement Drain Covers Designed For A Class Loading Duly Marked On Cover With Adequate Steel Reinforcement Having Thickness 75Mm To 150Mm Anti Corrosive Bitumen Painted M.S. Plate , Rim And M.S. Lifting Hooks, Admixtures Like Plasticizer, Bond Improving Compound, Shrinkage, Resistance Compound, Abrasion Resistant Complete As Per Approved Design Etc 471 Standard Size 600X800mm ( 75Mm Thick ) For Span 300 To 450Mm 472 Campus Lighting 473 Supply And Erection Of Octagonal Pole Of Following Length And Dimension As Per Table-3 With Base Plate On The Cement Concrete Foundation Of M-15 / M-20 Grade ( 1:1.5:3 ) With The Help Of Anchor Bolts Of Grade 6.8 ( Is 1367 P Iii ) . The Pole Shall Be Made Of S-355Jo Grade Steel Sheet , Folded Lengthwise To Obtained Octagonal Shape, Having Single Longitudinal Seam Weld And Hot Dipped Galvanised Internally & Externally In Accordance With Is 2629. The Pole Shall Have A Weatherproof Flush Door And Locking Arrangements. The Complete Work Shall Be Supervised And Certified By The Manufacturers For Satisfactory Supply, Erection, Testing And Commissioning. 474 7 Mtr 475 Supply, Erection And Fixing Of Hot Dipped Galvanised Overhang ( 60 X 3.25 Mm ) With Cap ( 250 X 137.9 X 4.05 Mm ) Over The Existing Poles 476 Single Arm Overhang 477 P & F Of Ip 65 / 67 Protected Led Flood Light System With Aluminium Housing, 3 X 1W, 220V, 50Hz Led Lamps With Dynamic Color Changing Capability Available In Quick Connecting Cable Coupled With Various Mounting Accessories. Ability To Create 16.7 Million Uniform, Smooth And Brilliant Colors Without Revealing Any Lamp Image. Available In 5 Colors – Amber, Green, Blue, Red And White. 478 Providing & Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Makein Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Underlayer Ofsand, Second Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size 479 10.0 Sq.Mm2 Cor 480 Repair Of Residantialbuilding At Churu, Bhaleri, Like Repair Of Plaster, Floor, Roof, Doors, Windows, Color Washing, Painting Etc. 481 Repair To Brick Masonary In Cement Sand Mortar With Taking Out Of Deceayed From Wall And Replaceing With New Briks.Cement Sand Mortar 1:6. With New Brick. 482 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 483 Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. 484 Cutting Jhiri Above 75Mmx75mm And Below 150X150 Mm Etc. And Making Good. 485 Scraping Old Surface And Redoing Lime Loi Or Sandla. 486 Renewing Glass Panes, With Puty And Nails Wherever Necessary: 487 5.5 Mm Thick Plain Glass Panes. 488 Renewing Glass Panes With Wooden Fillets Wherever Necessary: 489 5.5 Mm Thick Plain Glass Panes. 490 Providing And Fixing 16 Mm M.S. Fan Clamps Of Standard Shape And Size In R.C.C. Slab / Stone Slab Roofing Including Cutting Chase And Making Good And Painting Exposed Portion Of The Clamps Complete: 491 In Existing Roof. 492 Guniting Damaged R.C.C. Slab, Beams And Columns For Strengthening With Cement Sand Mortar 1:2 ( 1-Cement:2-Sand ) Including Preparing The Surface, Making V Shaped Joints, Cleaning The Reinforcement Bars With Jet Of Potable Water And Drying With Compressed Air, Including Cost Of Centering And Shuttering And Finishing To Match The Existing Surface Etc. Complete, Including Provided M.S. Welded Mesh To Gauge 25 Mm X 25 Mm Framing With Average Thickness Of 25 Mm. 493 Chopping Loose And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Blasting, Clening With A Jet Of Water / Air As Necessary And Getting It Dried With Compressed Air Including All Scaffolding: 494 Depth 50 Mm To 75 Mm. 495 Depth 75 Mm To 100 Mm. 496 Repairofdoor, Windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : 497 Style / Rail Of Teak Wood 30Mm Thick / Aluminium Section 498 4Wide 499 6 Wide 500 Panel By 501 Shuttering Ply - 9Mm Thick ( Commercial ) 502 Wire Gauge 14 Mesh X 24 Gauge 503 Plain Glass Panes 4Mm Thick 504 Aldrop Of Mild Steel 505 12 Long X12mm Dia 506 8 Long X 10Mm Dia 507 Stopper Of Aluminium With 508 Single Rubber Gutka 509 Double Rubber Gutka 510 Door Springs Of Mild Steel 511 Steel Hinges 512 For Wooden Chowkhat 3 Size. 513 For Wooden Chowkhat 4 Size 514 For Stone Chowkhat , 4Size 515 Mild Steel Tower Bolt 6 Long 516 Steel Locking Bolt 517 Steel Handle 6 Size 518 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 519 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 520 M10 Grade Nominal Mix 1: 3: 6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stoneaggregate 20Mm Nominal Size ) . 521 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggre -Gate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth. 522 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 523 20 Mm Thick. 524 Providing And Fixing Expanded Metal Mesh Of Size 20X60 Mm And Strands 3.5 Mm Vide 1.6 Mm Thick Weighing 3.64 Kg. Per Sqm. For Encasing Ofrolledsteel Sections In Beams, Columns And Grillages Excluding Cost Of Hangers. 525 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 526 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 527 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Fivelevelusing F.P.S. Bricks Of Designation 75 528 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 529 Brick Work In Partition In Super Structure Upto Five Storey 7Cm. Thick ( Brick On Edges ) Using F.P.S. Bricksof Class Designation 75 In : 530 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 531 Supplying And Fixing Machine Cut And Polished Stone Shelves, Tands And Sills In Cm 1:3 With Machine Cut Edges: 532 Kota Stone 25 To 30 Mm Thick. 533 Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills, Counters. Floors Etc. Laid On 12Mm ( Av. ) Thick Base Of Cement Mortar 1:3 Jointing With White Cement Mortar 1:2 ( 1 White Cement: 2 Marble Dust ) With Pigment To Match The Shade Of The Marble Slab Complete Including Grinding, Rubbing And Polishing Of: 534 Jhunjhunu / Jalore ( Red / Choclate Colour ) 535 Above 3601 Cm2 Slabs 536 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption’S Less Than 0.08% And Conforming To Is : 15622 Of Approved Make In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. 537 Size Of Tile 60X60 Cm 538 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 539 Category - I : Kajariya, Jhonson, Orient, Somani Make Etc. 540 Providing & Fixing In Cement Sand Mortar 1:4 Single Paitam ( Rebated ) Stone Doors Windows And Ventilator Frames Of Approved Quarry : 541 Size 100X75mm. 542 Size 125X100mm. 543 Providing And Fixing In Cm 1:4 Double Paitam ( Rebated ) Stone Door Window And Ventilator Frames Of Approved Quarry : 544 Size 125 X 100Mm. 545 Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal, Dehydreresin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure ‘A’ 546 30 Mm Thick Shutter 547 Commercial Veneer Both Side 548 Decorative Teakveneer One Side 549 Providing And Fixing Fully Paneled Double Leaf Shutter For Doors As Per Approved Design And Drawing With Approved Ordinary C.P. / Oxidized Steel Fittings As Per Annexure – A’ And Width Of Styles & Top Rails Of 100Mm And Lock Rails Width Of 150Mm And Bottom Rails Of 200Mm Width Including Teak Wood Beading Of Size 19Mmx12mm On Both Faces Complete : 550 30 Mm Thick Ghana Teak Wood Grade - I 551 Wire Gauge 24 Gauge 14 Mesh Of Is Designation 85 Gauge Wires Of Dia 0.56 Mm Panels 552 Demolishing Cement Concrete Including Disposal Of Material Within 50 Meter Lead : 553 1:3:6 Or Richer Mix. 554 Demolishing Of R.C.C. Work Including Stacking Of Steel Bars And Disposal Of Unserviceab Le Material Within 50 Meters Lead. 555 Demolishingbrickwork Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead. 556 In Cement Mortar. 557 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded With 15X3 Mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. 558 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 559 Providing & Fixing Ms Sheet Single Leaf Door Shutters In Angle Iron Frame 35X35x5 Mm Suitablly Diagonally Braced With 25X3mm Flat Ironabove And Below Lock Rail Of Size 50X5 Mm Beading Extra Includingall Fittings, As Per Direction Of Engg. Incharge But Excluding Coes Of Chokhats Including Two Coats Of Anti Corrastie Red Oxide Primer Panit. 560 Ms Sheet 18 Swg 561 Providing & Fixing Steel Glazed Doors, Windows And Ventilators With Shutters Of Standred Rolled Steel Section Joint Mitred And Welded With Steel 13X3mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required, Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Copper Glazing Clips And Special Metal-Sash Putty Of Approved Make, Or Metal Beading With Screws Complete Including Priming Coat Of Approved Steel Primer, Excluding The Cost Of Metal Beading And Other Fittings Except Necessary Hinges Of Pivots Steel Handles And Peg Stay Etc. As Required. 562 Patially Fixed And Partially Openable Fixed Area Not Exceed 33% 563 Supplying And Fixing Fixed Wire Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 564 14 Mesh X 24 Gauge 565 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 566 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 567 Distempering With Dry Distemper Of Approved Brand And Shade ( Two Or More Coats ) And Of Required Shade On New Work, Over And Including, Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 568 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 569 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 570 Old Work ( One Or More Coats ) . 571 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 572 Two Or More Coats On New Work. 573 One Or More Coats On Old Work. 574 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 575 For Area Of Each Slab Up To 900 Sq. Cm 576 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 577 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 578 Add 10 % For Water Supply And Sainatry Works 579 Add 10 % For Electric Works 580 Repair Of Boundry Wall At Pmc, Bhaleri, Including Provinf Fixing Of Borbed Wire Fancing Repair Of Gates Et. 581 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 582 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 583 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 584 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 585 Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. 586 Cutting Jhiri Above 75Mmx75mm And Below 150X150 Mm Etc. And Making Good. 587 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 588 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 589 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. M20 Grade Nominal Mix / Design Mix 590 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For : 591 Columns, Pillars, Posts And Struts Etc. 592 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. 593 Hot Rolled Deformed Bars ( Is : 1139 ) . 594 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 595 20 Mm Thick. 596 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 597 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 598 Structural Steel Work In Single Section Fixed With Or Without Connecting Plate Including Cutting, Hoisting ( Height Upto 10 M ) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. 599 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 600 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 601 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 602 Old Work ( One Or More Coats ) . 603 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 604 Two Or More Coats On New Work. 605 One Or More Coats On Old Work. 606 Part : E Electrical Works 607 33 Kvring Main Unit Consisting Of 2 Lbs At Incoming & 2 VcbSoutgoing As Per Requirements And Specifications. 608 Stranded Compact Circular Aluminium Conductor, Conductor Screened With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screened With Copper Tape, Cores Laid Up, Inner Sheath Of Pe Type, Galvanised Steel Flat Strip Armoured And Overall Pvc Sheathed Cable Confirming To Is 7098 / Ii / 85 With Latest Amendments Of 33 Kv ( Ue ) 609 3Cx300 Mm2 610 Providing & Making Heat Shrinkable Type Indoor / Outdoor / Straight Through Terminations / Joint Kit Of Approved Make Suitable For Xlpe Insulated 33 Kv Cable, With Required Components, Prepration Of Cable Ends, Testing Etc. 611 3 Core 240 / 300 / 400 Sq.Mm 612 Outdoor 613 Indoor 614 Sitc Of Floor Mounted Pmcc ( Indoor, Dust Proff Ip-4X Front Operated With 2 Mm Thick Sheet Metal Compartmentalised ) With All Accessible Parts, Head Shrinkable Sleeves, Smc / Dmc Bus Bar Supports, Padlocking Facility On Outgoing Feeders Etc. 615 Lv Capacitor With Apfc Panel 616 Sitc Of Microprocessor Based Intelligent Power Factor Correction Relay Having Sensitivity Up To 50 Milli Amp Secondary Current And Following Way, Self Analysing Auto C / K Setting According To Targeted Power Factor Setting, The Relay Shall Have Minimum Three Digit Display Unit For Display Of Real Power Factor, Targeted Power Factor, Lag / Lead Capacitor Switching Status, Alarm Output For Under Current, Over Current, Insufficient Compensation, Indication Of Switching On Units, Auto / Manual Status, And 6 To 14 Stage - Sensitivity Upto 50 Milli Amp. 617 Sitc Of Self Healing Mpp / Mp Type Shunt Capacitor ( Banks ) Conforming To Is:13340-41 / Iec :831-1&2 In Existing Panel Or Parallel With Load Terminals , The Capacitor Shall Be Fitted With Discharge Resistors, Pressure Sensitive Disconnector ( Psd ) And Shall Have Dissipation Factor Less Than 0.0025 At 50 Hz And Total Wattage Loss Less Than 0.5 Watt Per Kvar. Including Making Connections With Suitable Capacity Conductors / Cables Testing As Required.Heavy Duty Three Phase 440 V , 50 Hz Capacitor ( Bank ) 618 P / Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Make In Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Under Layer Of Sand, Iind Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size. 619 3 / Cx6 Sq Mm 620 3 / Cx10 Sq Mm 621 3 / Cx16 Sq Mm 622 3 / Cx25 Sq Mm 623 3 / Cx240 Sq Mm 624 Supplying And Making One End Termination With Heavy Duty Double Compression Brass Gland Sibg Type, Aluminium Lugs Duly Crimped With Crimping Tool, Pvc Tape Etc For Following Size Of Armoured Pvc Insulated & Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1100 Volt Grade As Required Of Size. 625 3 / Cx6 Sq Mm 626 3 / Cx10 Sq Mm 627 3 / Cx16 Sq Mm 628 3 / Cx25 Sq Mm 629 3 / Cx240 Sq Mm 630 Providing & Laying Xlpe / Pvc Pvc Insulated & Pvc Sheathed Armoured Control Cable Of 1.1 Kv Grade With Copper Conductor As Per Is 1275 Including Escavation Of 30Cmx 75 Cm Size Trench 25 Cm Thick Under Layer Of Sand And Lind Class Of Bricks Covering 631 3C X 2.5 Sq.Mm 632 5Cx1.5 Sq Mm 633 14Cx1.5 Sq Mm 634 Supply & Makingone End Termination With Heavy Duty Single Compression Brass Gland Sibg Type, Copper Lugs Duly Crimped With Crimping Tool, Pvc Tape Etc For Following Size Of Arrmoud Pvc Insulated And Pvc Sheated / Xlpe Almunium Cunductor Cable Of 1100 Volt Grad As Required Size. 635 3C X 2.5 Sq.Mm 636 5C X 2.5 Sq.Mm 637 14 C X 2.5 Sq.Mm 638 Supply, Fabricating & Installing Following Sizes Of Perforated Cable Trays Including Horizontal And Vertical Bends, Reducers Tees, Cross Members And Other Accessories As Required And Duly Suspended From The Ceiling With Suspenders And Including Painting As Required. 639 600Mm X 50Mm X 2.0Mm 640 150Mm X 50Mm X 1.6Mm 641 Supply, Installation, Testing And Commissioning Of Copper Wound Transformers 33 / 0.433 Kv, Three Phase, 50 Hz, Dyn 11, Onan Type , Standard Accessories With Off Load Tap Changer ( +5% To -10% In Steps Of 2.5% ) , Winding / Top --- Temperature Rise Of 45°C / 40°Cfirst Fill Oil, Having Permissible Total Loss Values Not Exceeding 7.5% Of The Maximum Total Loss Values For 11 Kv As Per Energy Efficiency Level - 2 At Basic Insulation Level Conferming To Iss 2026 ( Part- I To Part - Ii ) , Latest Ammended And Is 1180 Part-I : 2014. Transformers Described As Above And As Per The Following Continuous Rating 642 400 Kva 643 1250 Kva 644 1600 Kva 645 S.I.T.C. Of Bus Duct Arrangement In Convenient Sections Complete With Enclouser Of Crca Sheet Steel Of Minimum 2 Mm Thickness, Aluminium Bus Bar And Earth Bus For Use On 3 Phase, 4 Wire, 415 Volts, A.C. Supply With Degree Of Protection Ip-42 For The Following Current Carrying Capacity, Including Jointing Of Sections, Copper Flexible Joints. Expansion Joints, Bends, And Earthing With 2 Runs Of Alum. Strips Etc. As Required 646 1 Straight Run With 2 Earth Bus 3200 Amp 647 Bend 3200 Amp 648 Copper Flexible Tpn 3200 Amp 649 Supply Installation Testing & Commissioning Of Local Push Button Stations 650 Maintenance Free Gel Earthing With Pipe In Pipe / Strip In Pipe Technology Filled With Anti Corrosive Conductive Compound ( Cpri Tested ) Below The Ground In 150 -200 Mm Dia Earth Pit And Surrounding Filled With Required Mineral Filling Compound ( Mfc Should Have Hygroscopic Proper Ty To Retain The Moisture For Long Time To Create Low Resistance Zone ) And C.C. Finished Chamber Covered With Hinge Type With Locking Arrangement C.I Cover. C.I. Frame Of Size 300Mm X300mm Complete Testing Of Earth Resistance As Required Of Following Sizes With Pipe In Pipe Technology ( Inner Pipe Dia / Outer Pipe Dia ) 80 -100 Micron G.I. Coating Of The Size G.I. Pipe 3000 Mm Long , 80 / 40 Mm , Terminal 14 Mm G.I. Strip 651 S & Laying Following Size Earth Wire / Strip In Horizontal Or Vertical Run In Ground / Surface / Recess Including Riveting, Soldering, Saddles, Making Connection Etc. As Required. 652 50Mm X 6Mm G.I. Strip 653 25Mm X 6Mm G.I. Strip 654 25Mm X 3Mm G.I. Strip 655 10 Swg G.I. Wire 656 P & F Lightning Conductor Final Made Out Of 25 Mm Dia., 300 Mm Long Copper Tube Having Single Prong At Top With 85 Mm Dia., 3 Mm Thick Copper Base Plate Including Holes Etc. Complete As Required. 657 Part : F Instrumentation & Scada 658 Sitc Of Ultrasonic Level Transmitter Suitable For Measuring Water Level In Reservoir, Normal Powered 24Vdc, Type Of Transmitter: Two Wire ( 4-20 Ma ) , Cable Entry:1 / 2 Npt ( F ) , Sensor Material: Pp, Slip-On Flange: 2 ½” Flange, Material Of Construction For Slip-On Flange: Pp, Output 4~20Ma, Hart Compatible, Accuracy + / _ 0.2 % As Per Detailed Technical Specification, Scope Of Work And Direction Of Engineer In Charge. Measuring Range 0.0 To 6.0 Mtr 659 Providing, Installation, Testing And Commissioning Of Diaphragm Type Pressure Gauges Dial Size 150 Mm Glycerin Filled Shatterproof Glass, Over Range Protection: 125% Of Maximum Pressure, Material Of Sensor And Other Wetted Parts: Ss Type 316, Housing Material: Die Cast Aluminum 660 Providing, Installation, Testing And Commissioning Of Pressure Transmitter For Water Application: Range: 0-10 Bar / Power Supply: 24 V Dc / Output: 4-20 Ma With Hart / Diaphragm: Ss316l / Process Connection: 1 / 2 Npt ( M ) / Accuracy: 0.15% Protection: Ip671 / 2 M ( Npt ) 661 Sitc Of D / F Full Bore Type Electromagnetic Flow Meter Of Approved Make Of Following Dia And Specifications Complete: Media : Water ( Raw / Chlorinated ) , Pressure : Up To 1.5Mpa, Process Temp: - 50 Deg C, Flow / Meter Tube : Ss 304, Electrode : Ss Aisi 316L / Hastelloy C276 / Tantalum, Lining Material : Hard Rubber / Neoprene / Poly-Urethane ( Pu ) , Flange : Ss / Cs, Flange Standard & Rating : Ansi 150, Coil Housing : Ss Aisi 304 / Carbon Steel / Die Cast Aluminium, With Anticorrosive Paint & Provide Completely Sealed ( Leak Proof ) Construction As Per Requirement Of Iec 60529, Accuracy : ± 0.5 % M.V.- Velocity 0.3 To 10 M / S, Transmitter / Signal Convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V Ac - 50Hz, Output 1 : 4-20 Ma, Output 2: Pulse, Communication Output : Rs 485 / Heart, Display Type : Lcd / Led Display, Cable Entry : M20 X 1.5, Provision Of Ram / Prom To Store Calibration And Configuration Parametersand Totalizer Value During Power Failure, Protection Category- Ip 68 For Sensor ( Flow Tube ) And Ip 67 For Transmitter / Convertor, Including Surge Arrester, If Required, And All Materials Required For Making Connection With Existing Pipeline Including Cutting The Existing Pipeline Etc. Complete In All Respect As Per Technical Specification And As Per Direction Of Engineer In-Charge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 662 150 Mm Dia 663 200 Mm Dia 664 250 Mm Dia 665 400 Mm Dia 666 900 Mm Dia 667 Sitc Of Bulk Flow Meter With Removable Mechanism Class B Confirming To Iso:4064:2005 / Is: 2373Of Approved Make Of Following Dia Sized Pipelines And Specifications Complete:Media : Water ( Clear ) , Temp. 50 Deg., Pr. Rating: Pn16, Protection Type: Ip- 68, Body Material : Is-210 Gr. Fg-200, Accuracy Class :Class B ( ±2 % @ Nominal Flow Rate ) , Magnetic Drive, Dry Dial, Epoxy Powder Coated, Pulse Out Put Option, Anti-Magnetic Protection Including All Materials And Making Connection With Existing Pipeline Required For Bulk Flow Meter Including Cutting The Existing Pipeline Etc. Complete In All Respect As Per Technical Specification And As Per Direction Of Engineer In-Charge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 668 Bfm 100 Mm 669 Bfm 150 Mm 670 Bfm 250 Mm 671 Sitc Of Rtu Complete With Di, Do, Ai And Modbus Communication Ports And Power Supply ( 24 V, Dc ) 672 Providing And Laying Stranded / Flexible Annealed Bare Copper Conductor , Xlpe / Pvc Insulated 2 Pair 1.5 Sqmm Suitably Laid Up Together Overall Polyester Taped Al ( Mylar Tape Wrapped ) Along With Atc Drain Wire Overall Pvc Sheathed ( St-1 ) Overall Screened Triad Armoured Instrumentation Cables Generally Confirming To Pas 5308- Part-2-2009 673 Providing & Laying Xlpe / Pvc Pvc Insulated & Pvc Sheathed Armoured Control Cable Of 1.1 Kv Grade With Copper Conductor As Per Is 1275 Including Escavation Of 30Cmx 75 Cm Size Trench 25 Cm Thick Under Layer Of Sand And Lind Class Of Bricks Coveringsize 3C X 2.5 Sq.Mm 674 Supply, Installation, Testing And Commissioning Of Mnre Approved Off Grid Solar Panels For Running Of Motor Pumps With 25 Years Of Linear Generation Warranty, Work Includes Designing Of Solar Panel Area And Ms Frame And Foundation On Ground / Roof Of Pump House Or Cwr, Showing Arrangement Of Panel In Available Space, Installation Of Pv Module On Ms Frame As Per Approved Design And Drawings. Mounting Structure Shall Be Suitably Design To Withstand Wind Velocity Up To 150Km / Hr. The Work Shall Be Executed As Per Detailed Technical Specifications, Approved Drawing And Direction Of Engineer In Charge. Note: There Shallbe5 Year Service Warranty For Solar Panel And Mounting Structure Andsuitable Provision Shall Be Included In Tender Document ( Each Of .5 Kw ) 675 P&F Of Gsm / Gprs Based Data Transmitter Device Forwater Meter Compitable To Scada System. 676 Supply, Installation, Testing, Commissioning Of Plc / Scadasystem Including All Hardwares, Softwares, All Accessorings For Thefollowingpump Houses As Per System Configuration Alongwith Scada For Master Control Centre For Monitering The Water Supply. As Per Scope And Specificationscomplete In All Respect. Ans As Per Direction Of Eic At The Following Locations. 677 Cps Bhalari 678 Supply, Installation, Testing, Commissioning Of Master Control Room Including All Plc / Scadasystem, Hardwares, Softwares, All Accessorings For Thefollowingpump Houses As Per System Configuration Alongwith Scada For Master Control Centre For Monitering The Water Supply. As Per Scope And Specificationscomplete In All Respect. Ans As Per Direction Of Eic At The Following Locations.Churu 679 Part G : Operation & Maintainance & 680 Cost Of Operation And Maintenance Of The System For 10 Years After Defect Liability Period Of One Year @ 6.0%On Above Items Excluding Villages Inrta Systemand As Per Scope Of Work & Specification 681 Operation And Maintenance Charges 1St Year 682 Operation And Maintenance Charges 2Nd Year 683 Operation And Maintenance Charges 3Rd Year 684 Operation And Maintenance Charges 4Th Year 685 Operation And Maintenance Charges 5Th Year 686 Operation And Maintenance Charges 6Th Year 687 Operation And Maintenance Charges 7Th Year 688 Operation And Maintenance Charges 8Th Year 689 Operation And Maintenance Charges 9Th Year 690 Operation And Maintenance Charges 10 Th Year 691 Part H : Dismantling Of Old Pump Sets 692 Cost For Dismantling Of Old Pump Sets, Electrical Panels And Intrumentation Etc And Depositing In Depatmental Stores As Per Direction Of E.I.C. 693 Tps Karamsana 694 Ir-4 695 Cps / Tps Bhaleri 696 Cps / Tps Churu
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
24.
Housing Urban and Rular Development #10235078 Price Bid
Tender For New Construction Of Cheriyan Nagar Library Chennai; 1 DISMANTALING WORKS 2 Dismantling etc., all complete 3 Brick / Stone Masonry in lime mortar walls 4 Dismantling RCC by manual / by using deploying machineries 5 Doors and Windows including removal of frames, hinges and fastenings 6 CIVIL WORK 7 Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size bouldersand Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrockrequiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete SS.20B 10 cum 8 Carting away surplus excavated earth available with in the campus is to be carted to a lead of within 40 KM from site. The rate shall include loading into the tipper/ lorry transporting and unloading, leveling and the earth scooped by bulldozers grading etc.,complete with all respects complying with relevant standard specification, as directed by the Departmental Officers. Rate to include materials, loading, unloading, transportation, plant and machinery, hire and fuel charges for tools and plants and other incidental charges, royalties, seignorage and taking statutory approvals as necessary to carry out the work as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 9 Supplying and filling in foundation andbasement with Crushed Stone Sand (M- Sand) in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. 10 Supplying and filling in foundation, basement, etc with filling Gravel inwellrammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 11 Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 12 Providing pre-constructional Antitermite treatment including cost of chemicals labour as per standard specifications for preparing the area for treatment by spraying chemicals and other incidental charges etc.. complete. The rates should be for antitermite treatment from the plinth beam and brick masonry with super structure in contact with the back fill earth and at the junction of the walls.The top surface of filled earth for flooring and the soil along with the perimeter of the building by making holes with the crow bar and poured 5% termicide “Chloripyrifos” and sprayingthe same termicide solution on the wooden frames and treating the other periphery of buildings etc., complete in all respects as per IS 6313 (part II) / 1981 and as directed by the departmental officers. 13 Supplying and erecting centering for sides and soffits including supports and strutting up to 3.30 m height with all cross bracing for plane surfaces as detailed below, using mild steel sheets of 90 X 60 cm 10 gauge stiffened with MS angle of 25 X 25 X 3mm for boarding, laid over adjustable span & jacks and supported by 50mm dia pipes for general pipes scaffolding systems @ a spacing of 1.20m c/c and vertical connected at a height of 2.0m c/c including C & U clamps and base receiver cup at bottom for connecting pipes etc and removable systems etc.,Rate to include all materials, labour charges, wastages ,placing, transportation, lead & lifts, tools & plants, fuels, fixing in position at all levels, heights, masking tape in sheet joints, consumables, etc. as complete with all respects complying with relevant standard specification, as directed by theClient / Engineer-in-charge. 14 For Column footing, plinth / grade beam, bed blocks, template surfaces, steps, piers, raft slab / beams and such other members 15 for plane surfaces such as rectangular or square rcc columns, sunshades, topand bottom slab of rcc boxing, etc. 16 Plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slab / beams and such other members 17 Providing and Laying M 30 Design Mix for all reinforced cement concrete with minimum cement content conform to IS 456-2000 using ordinary Portland cement of grade 53 from approved manufacturer, manufactured sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement. works for Raft, Grade beam, Shear wall, RCC walls, Lift walls, Plinth beams, Column, footings, Grade slab, Roof slab & beam, Curved slab, beam, Column drops, Pergola, Staircase waist and landing slab lintel, Sunshades, parapet Cum drops, Steps, canopy, window boxing slab, Loft, fins facia Planter box binders basement retaining wall, machine foundation, elevation features and other similar structures etc..excluding necessary centering, shuttering and reinforcement which shall be measured and paid separately under relevant items. 18 For FoundationandBasement 19 For Ground Floor 20 For First Floor 21 For Second Floor 22 Supplying, fabricating and fixing in position of steelFe 550 grade Reinforcement for all RCC work with Thermo Mechanically Treated Bars (TMT) conforming to IS 1786 of latest version according to drawings and binding the reinforcement with 18 gauge double fold GI binding wire and providing Concrete / PVC cover blocks to maintain the cover as required.Rate to include all bending, tying grills, placing, transportation, lead & lifts, tools & plants, fuels, all materials, labour charges, wastages , laying at all levels, fixing in position, cost of cover blocks, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 23 Supply and constructing Fly ash Brick (230 x 110 x 75mm) masonry in Cement Mortar 1:5 (One cement and Five M sand) in foundations, basement and superstructure usingFly ash Bricks of size 230x110x75mm etc. Rate to include all materials, labour charges, wastagesfor working at all levels with necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, curing, fuel, consumables as complete with all respects complying with relevant standard specification and as directed by theClient / Engineer-in-charge. 24 For Ground Floor 25 For First Floor 26 For Second Floor 27 Providing two legged scaffolding using 15 cm dia casuarinas post of 4 M over all length (3 M Height + 0.5 M Projection + 0.5 M into the Ground) the distance between the two rows being 1.25 M and the spacing of posts being 2.0 M in both the rows with two horizontal posts with 0.5 M. Overlap on either side and braces at 2.0 M Center to center including longitudinal and transverse middle braces to step up and providing a platform with country wood planks of 40 mm thick and 1 M width, etc. in a complete from using coil and nails. 28 Upto 3 M Height 29 3 m to 5.5 m Height 30 5.5 m to 7.5 m Height 31 7.5 m to 10 m Height 32 10 m to 12.5 m Height 33 Plastering 10 mm thick for ceiling including slabs, beams and column drops and staircase waist slab, sunshade, drops, chajjas etc..with Cement Mortar 1:3 (1 of cement : 3 of P sand) according to the specification. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 34 Plastering 15 mm thick for external surfaces with Cement Mortar 1:5 (1 of cement : 5 of P sand) with water proofing compound of “CICO No.1 or equivalent“ as per Manufacturers Specification with sponge finish (washed sand finish) all complete as per specification and as directed. The rate includingcost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds, grooves to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 35 Plastering of 12 mm thick for Internal walls with cement mortar 1:5 (1 of cement : 5 of fine river sand)according to specifications. Rate shall include for providing GI chicken mesh of nominal thickness at the junctions of masonry and concrete works to a width of 100 to 125mm including tying in position with suitable clamps/screws. Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, transportation charges, loading, unloading, preparation of surface, necessary hacking in RCC surface, scaffolding, stagging, tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 36 Painting the new plastered walls with two coats for Interior Plastic Emulsion paint approved quality and colour over a priming coat, with two coats of wall putty including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. 37 Painting two coats for Exterior surface with approved Exterior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. 38 UPVC Window Specification:Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work 39 UPVC VentilatorSpecification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profilethe size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles arereinforcedwith GI/1mm 125GSM and 100% corrosion free, the profile are multi chamberedsections with wall thick of2mm.The EPDM rubber (black colour) covered with all over the edges of frame and shutter.The corners and joints should be welded and cleaned.Radiations pin headed glass 4mm thick should be provided in the louvers.The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames.The ventilator should be got approved from the Executive Engineer before use on work 40 Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification. 41 Painting the new Iron work with two coats of Ready Mixed Enamel Paint of aproved quality and colour over the existing priming coatincluding the cost all materials etc.,complete, in all floors and as directed by the Departmntal Officers. 42 Providing and fixing Vertical blinds , quality of approved make fabric made of 100% polyester woven fabric thickness 0.40mm with virtually maintenance free having plastic bottom chain thickness of chain-0.50mm and diameter-3mm, Plastic with metal bottom and suitable coating on exterior, including all fixtures and fittings complete in all respect as per design/color/shade including requisite installation brackets etc as required for installation at site with anchoring arrangements complete. 43 Supply and laying with best quality the following materials of Ruby Red, Raw Silk Granite Slabs (Super Fine Polished with Machine Cut Edges) of sizes 4’x2’ and above 18mm to 20mm thick Thick including cuttingand edge polishing to be set in CM 1:3 (1 of cement : 3 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish.Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing,cleaning, acid wash over finished surface, protection with Gypsum / Poplayeroverplastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 44 Supply and laying with best quality the following materials of Sinthetic Grey, Paradise and similar varieties Granite Slabs Granite Tiles - (Superfine Polished with Machine Cut Edges) of size 2’0” x 1’0” and above 10mm Thick including cuttingand edge polishing to be set in CM 1:3 (1 of cement : 3 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish.Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing,cleaning, acid wash over finished surface, protection with Gypsum / Poplayeroverplastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 45 Nosing for Granite Slab-Single Nosing 46 Grooving the Granite Slab 47 Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer.The colour & quality of tiles should be got approved by Executive Engineer before use on work 48 Paving the floor with design Antiskirt Ceramic tiles (colour and shade as directed) of size 305 mm x 305 mm x 6 mm in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick laid in-situ and pointed with same coloured cement. 49 Supplying and fixing Dadooing the wall with ceramic tiles of approved quality, colour and design joint free of size 600x300x10mm thick of approved make, in all floors over a base layer of cement mortar 1:2 (one cement: Two sand) 10mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 50 Supplying and filling the sunken slab area by BRICK-BATCOBA by adding CICO NO:1 of approved equivalent admixture including applying two coats not less than 2 mm thick of TAPECRETE- Acrylic Polymer Based Naterproof Coating, over the final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with water proofing compound like CICO No.1 at the rate specified in the manufacturers specification after entire completion of laying pipes, sanitary fittings etc Rate including all mater aaod and lifts, working materials, labour charges wastages with necessary lead and at all levels, protecting the laid pipes and sanitary fittings, finishing the surface smooth to receive the top coat of water proofing application etc. as complete with all respects complying with relevant standard specificatior and as directed by the Client/ Engineer-in Charge 51 Including applying two coats not less than 2 nm thick of TAPECRETE- Acrylic Polymer Based Waterproof Coating, over the plastered surface as including final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with approved water proofing compound like CICO No. 1 or approved equivalent conforming to IS 2645 at the rate specified by the manufacturer over coated surfacepreparation of surface, finishing, curing etc. all complete at all levels as per manufacturers specifications and as directed. 52 Waterproofing: Providing and Applying CFTRI approvedtwo component flexible polymer modified acryliccementitious waterproofing coating with a mix ratio of(5 Liquid :7 Powder) to the RCC surface of the UGT/OHT tankapplied @ 2.2kg/m2 in 2 coats to achieve1.2mm DFT, having Elongation at break >120% asper ASTM D 412, Tensile strength >1N/ mm2 as per ASTM D 412, Adhesion strength: 0.80N/mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right anglesof wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completelyas per specification. Followed by applying 15 mm thick dimensionally stable fibrous reinforced cementitious structural grade dual shrinkage Polymer Mortar on as protective plastering @ 29kg/m2. The material having Compressive strength of 38 MPa at 28 days as per EN 12190, Adhesive Bond Test, >1.5 Mpa as per EN1542, followed by Water curing by sprinkling water for 3 times a day for 5- 7 days. Followed by applyingtwo component, water-based food grade epoxy resin coating on inside surface of Potable water tank having anti algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 – 300 of US – FDA, having mixing Ratio (Base: Hardener: Water) – 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification 53 Finishing the top of roof with one course of Solar Reflective ceramic tiles of size 305 mm x 305 mm x 7 mm of approved quality in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete 54 Supplying And Fixing Rubber Moulded Interlocking Paver Blocks Against Available Edge Restraints 83 mm Thick of Approved Design And Pattern of Strength 40 N/Sq.m. 10 mm Iss Metal With Minimum Cement Content As Applicable To M 40 Grade Concrete As Per Is-456-2000 Manufactures By Mechanical Or Hydraulic Machine Using Vibro- Compaction Process And Laid Over 50 mm Thick Laying Course (Bedding) Crushed Stone Sand (M Sand) Well Compacted By Plate Compactor With A Joint Width of 2 mm To 5 mm Including Filling of All Joints With Crushed Stone Sand (M Sand) And Compacting The Paved Surface With Plate Compactor Two Or Three Times Until All The Unit-To- Unit Joints Are Completely Filled With Crushed Stone Sand (M Sand) And Trimming The Edges Neatly Including All Labour Charges And Plate Compactor Charges Etc. Complete(Cost Inclusive of Crushed Stone Sand (M Sand)) 55 Supplying and fabricating of MS structural steel supports for various applications using channels, MS angle iron, bolts, nuts, anchor bolts etc., required for the work, cut to the size, bent to shape, welding, grouting etc., complete. Supports shall be powder coated with required colour for different system as mentioned above. 56 Providing Teak wood wrought and put up for frames of doors, windows and ventilators and any other similar joinery works including cost of country wood scantlings and labour charges for manufacturing the frames and fixing hold fasts and fixing in position etc. for all lengths as per architect designs. 57 Best Indian Teak Wood Panelled door in double shutters with frames 100x75mm at side,verticals and top. The shutters shall beof 40mm thick with moulded panels in 20mm thick planks,6Nos.of iron hold fasts fixed in c.c.1:2:4 6Nos.of butt hinges 125mm long including wind appliances, furniture,iron fittings,1No.of iron padlock 15cm long for locking arrangements and fixing inposition,etc.,complete.(ISI STD) 58 Varnishing the new wood work one coat with best shellac and with fine best varnish of approved quality varnish of teak wood natural finish including preparation of surfaces with sand papering in patty priming etc., complete complying with standard specification and as directed by the Departmental officers. 59 Solid PVC Door Shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC Sheets. Shutter using 5mm thick solid PVC Sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm with suitable rabate for housing the shutter 60 Best Indian Teak Wood panelled door shutter for single leaf door. The shutter shall be 40mm thick with moulded panels in 20mm thick planks inclusive of 3 Nos.butt hinges 125mm long,furniture iron fittings,1No.of jappened hooks and eyes 200mm long and 6mm thick and iron pad lock 15cm long including fixing inposition,etc.,complete 61 FALSE CEILING WITH GYPSUM PLAIN TILES Providing and fixing true horizontal level false ceiling using SAINT -GOBAINGYPROC or Equivalent make with 24 mm Grid system using hot dipped galvanised Steel Section, exposed surface chemically cleaned caping prefinished in backed polyestar paint wall angle of size 24mmX24mm used in the periphery of the ceiling fixed to the wall partition R.C. Column bandwalls with the help of screws Column bandwalls with the help of screws at 600mmc/c. Main runner of size 32X24mm suspended at1200mm c/cmax by using securely fixed to the structural soffit of R.C.C. slab by using 6mm Nylon Rawl plug at every 1200mm (Max) and 1200mm long Cross Tee of size 24X24mm to interlocked between Mainrunner at 600mm c/c (max) to form a grid of 1200mmX600mm. 600mm long Cross Tee of size 24X24mm is inserted to form a grid of 600mmX600mm and finally tiles laying 62 Art work as per the direction of department official, over Oil Painting with first class quality and approved colour including a priming coat with thorough scrapping clean removal of dirt., etc., complete and including necessary plaster of paris, putty, etc., wherever required (Relevent ISI STD), including putty works. 63 Supplying and Fixing of English Stainless Steel Letters of 25cm (10”)size and approved colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes 64 Supplying and Fixing of Tamil Stainless Steel Letters of 25cm (10”)size and approved colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes 65 upplying and Fixing ofEmblem (15”) Stainless Steel size and approved colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes 66 Supply and fixing of Pre-fabricated Structural Steel, coated galvalume ROOFING SHEET of 0.5mm thickness with SMP coating with colour bond XRW coating, having minimum of 550 Mpa yield strength, Coating 150 GSM as per ASTM 792 or equivalent standard. The structural roofing Panel shall have 1020 mm effective width, nominal 30 mm crest height at nominal 250 mm centre to centre pitch with the embossment (share grove) on top & side of ribs for better composite action including Flashing for joints, and all incidental charges. 67 Supplying and erecting in position LIGHT DUTYSTEEL TRUSSES as per the drawing.The materials and design of the trusses should confirm to the relevant Indian Standard specification.The trusses shall be procured only from reputed manufactures oftrusses with prior approval of the Buildings Engineer and a certificate to the effect from the reputed manufacturers shall also be furnished with design.The rate quoted shall include the cost oftrusses.Base-plate with holding down bolts and nuts to RCC or Masonry works, roof purlins, rafters, purlin sleeves, the members fixing accessories etc., painting one coat of red-oxide paint and erecting in position etc., complete as directed during execution. The contractor shall also arrange to provide grouting for holding down bolts embeding the end purlins, to the gable wall wherever necessary etc.,The roof sheeting shall project 0.762m from the eves purlins. 68 Providing Wall Panelling using one side teak wood sheet with melamine polishing with following specification. The frame using aluminium tubular section of size 50mm x 25mm x 2mm thick fixing horizontally and vertically in position with wall at interval of 0.60m in both diretions, fixing water proof plywood of 12mm thick over the aluminium frame work with necessary screws. One side teak wood sheet of 3.5mm thick will be fixed over the plywood using fevical and finishing with melamine polishing and the rate inclusive of conveyance to site and labour charges and as directed by the Departmental Officers. The design pattern, water proof plywood, OST sheet and other materials to be used shall be got approved by the Executive Engineer concerned before use on work etc., complete. 69 Providing, supplying, and fixing factory-manufactured pre-fabricated insulated roofing panels made of PUF (Polyurethane Foam) sandwiched between two metal skins, comprising pre-painted galvanized iron (PPGI) sheets of 0.5 mm thickness on both sides with 40 mm to 50 mm thick CFC-free polyurethane foam core of minimum density 40 kg/m³, having tongue and groove jointing with cam-locking arrangement for weather-tight sealing. Panels shall have minimum overall R-value of 6.5 and thermal conductivity not more than 0.022 W/m·K. Roofing to be supported over structural purlins/trusses using self-drilling screws with EPDM washers, sealants, fasteners, ridge covers, and flashing, complete. Rate includes supply, transport, hoisting, cutting to size, edge finishing, foam taping at joints, sealing, labour, tools, scaffolding, and all incidentals for a fully finished, insulated, and weatherproof roofing system as per manufacturer’s specification and as directed by the Engineer-in-Charge. 70 Brick Wall Cladding Nuvocotto Edge Cut Wall Tiles Natural Red finish in size 230mm x 76mm x 15mm 71 Brick JalliNuvocotto Camp Jallie Natural Red finish in size 200mm x 200mm x 60mm 72 Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT 73 Supplying of plastic Potted plants Anthurium size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 74 Supplying of plastic Potted plants Bogainvillea size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 75 Supplying of plastic Potted plants Ficus ponda size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 76 Providing & laying spreading & Compacting graded stone aggeragate of size 45mm to 22.4mm, 22.4mm to 2.36mm & 2.36mm to 75 microns to Wet Mix Macadam (WMM) specification including premixing the material with water at OMC in Mechanical mix plant carriage of mixed material by tipper to site, laying in uniform layers with paver in Sub base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density, rate including the cost & conveyence of all materials, labour charges for spreading, watering, rammed & consolidation and other tools & plants employed for the work etc., all complete and as directed by the departmental officers as per MORTH specification 406 IV Revision 77 Supplying and filling with M-Sand well watered rammed, and consolidated complying with relevant standard specifications etc., complete and as directed by the departmental officers. 78 ProvidingandlayingofBlackGraniteCobbleStoneflooringof approvedmake,inallcoloursandshades,laidon20mmthick cementmortar1:4(1cement:4coarsesand),jointingwithgrey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 79 SupplyingandlayingGrassPaverblock M40grade Providingand layingof 63mm thickhighstrengthtypeconformingIS15658- 2006ofrubberizedinterlockingpaverlockinsizeofminimum compressivestrengthof40N/mm2inuniformshapeofapproved maketobelaidinflurringbonepatternwithsandcushionbelow theuniformshapofapproved nonskittingsurfaceinthetopand therateincludinglevellingthebasepreparationof paversassub base,sandcushion150mmthicklaying outofpavementcutthe piecestofixtheedgevibringthepavers,sweepingtranporting loadingunloadingoflayingpaverblockasperstandard specification,. 80 PLUMBING 81 Supplying and fixing in position White / Colour Glazed Model Floor Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, unioncoupling connected by means of 40mm white PVC flush hand using indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) Floor Fitting. 82 Supplying and fixing Stainless Steel Health Faucetwith all the accessories etc, 83 Supply and fixing White without PedastalWash Hand Basin of size 550mm x 400mm with all accessories such as Cast Iron Brackets, 32mm dia CP Waste Coupling, Rubber Plug and Chain, 32mm dia B Class GI Waste Pipe, 15mm dia GM Wheel Valve, 15mm dia Nylon Connection, 15mm dia Brass Nipples,15mm CP Pillar Tap etc (The wash basin should be got approved by Executive Engineer before use on works). 84 Providing and fixing C.P. Angle stop cock of approved quality conformingto IS:8931 :15mm nominal bore 85 Providing and fixing Brass Chromium Plated Towel Rail 60cm long and20mm dia with Brackets etc,. 86 Providing and fixing Brass Chromium Plated Soap Tray of size 150mm x 100mm 87 Providing, fixing and testing of PVC soil, waste and vent pipe confirming to IS 13592 of SWR quality 6 kg / sq.cm pressure rated 10mm, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cementfollowed by application of leak proof adhesive like FRP paste, fixed to wall with properly fabricated MS bracket of suitable size, GI U clamps with bolts, nuts and GI washers complete, for soil and waste pipe lines. 88 75 DIA 89 110 DIA 90 Providing, fixing and testing of PVC waste pipe of agricultural sereis conforming to IS 4985 including all fittings like tees, elbows, bends, collars, coupling, etc jointing with solvent cement followed by application of leak proof adhesive like FRP paste laid on floors inside the toilets to the required slope including making necessary bores in walls / foundations / concrete slab as applicable, making good the bores with CM 1:3 or cement concrete as applicable, curing etc., complete. 91 40 DIA 92 Providing, fixing and testing of PVC floor- trap 110 dia with necessory of multitrap connection (heavy duty hinged type) with brass CP frame & cover (100 mm x 75 mm). Trap of 100 mm dia inlet and 75 mm dia outlet fixed on a bed of cement concrete etc.complete. (The frame and grating shall be approved by Architects) 93 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water Providing, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(Concealed On Wall) 94 20MM DIA 95 25MM DIA 96 Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) : 97 25mm dia Cost of gate valve 98 32mm dia Cost of gate valve 99 Providing, installation, testing and commissioning approved make CIY-type Strainer conforming to IS standardwithnecessary companion flanges, neoprene gaskets(10Kg/sq.cm. pressure rating) nuts and bolts including all the accessories to complete the work as per the specifications. 100 32 mm nominal bore 101 Providing, fixing and testing of PVC soil, waste and vent pipe confirming to IS 13592 of SWR quality 6 kg / sq.cm pressure rated 10mm, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cementfollowed by application of leak proof adhesive like FRP paste, fixed to wall with properly fabricated MS bracket of suitable size, GI U clamps with bolts, nuts and GI washers complete, for soil and waste pipe lines.(Pipes Runningin the Shaft & below ground level) 102 75 DIA 103 110 DIA 104 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water Providing, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(Pipes Runningin the Shaft & below ground level) 105 25MM DIA 106 32MM DIA 107 Providinging and fixing in position PVC Vent cowls of following dia of best approved quality conforming to BIS, etc., complete complying with standard specifications.(The PVC cowl should be got approved by the Executive Engineer before use on works). 108 75MM DIA 109 110MM DIA 110 Providing and fixing GI. puddle flanges (IS; 1239) fabricated out of 6 mmthick M.S. plate of size 300 x 300mm plusdia of pipe of 750mm long pipe pieces fixed to RCC wall of water tanks. Including painting with two coats of primer complete as required. The entire fitting shall be hot dipped galvanized.(Rate As per Quotation) 111 32 mm dia 112 40 mm dia 113 50 mm dia 114 65 mm dia 115 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:(Rate As per Quotation) 116 Constructing in site of Inspection chambers comprising burnt brick/solid block masonry walls of 230 mm thk., built in CM 1:4 over M-15 CC bed of thickness 100 mm ,Heavy duty RCC precast cover (SFRC), benching in CC M-15, internalfaces plastered smooth in CM1:4, 15mm thick and outside Rough Plastered with CM 1:6, 15mm thick including necessary earth work excavation returning and refilling and disposing surplus soil as directed by the Engineer in charge. 600x600 mm size internal and depth will 450mm to 1200mm & 900x800 mm size internal and depth will 450mm to 1200mm. (Rate As per Quotation) 117 600x600 118 Making of core cutting in RC slab of maximum 150mm thick of following diameter. 119 a) 150 mm dia 120 b) 125 mm dia 121 Providing and fixing MS slotted angle iron brackets, hangers, MS grip bilts,universal clamps with thereaded rod,supports with necessary drilling holes to suit the insertion of pipe clamps, deburring etc., as per detailed drawing for supporting soil, waste and rain water pipes and water Providing pipes in shafts with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls/outer walls etc., The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08 mm thick conformed to IS 1239 etc., complete as directed by the employer. 122 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality.(600x600mm) 123 Providinging, installing, fixing, jointing, testing and commissioning of PVC Storm water pipe confirming to IS 13592 of SWR quality 4 kg / sq.cm pressure rated 10mm, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cementfollowed by application of leak proof adhesive like FRP paste,The quoted rate shall include necessary earth work, fittings,pipe to be laid below ground level in trenches upto required depth, dewatering, jointing of pipes, water testing and setting,refilling, and making good the same complete as required. 124 110 DIA 125 Providing, fixing and testing of Terrace Rain water outlet (110dia) with all the accessories etc,. 126 INTERIOR 127 BOOK SHELF 1 - 2100 x 400 x 2100 Carcass are 16mm MR Ply with 0.72mm Backer Laminate on both Sides, Shutters are 16mm MR ply with One Side 0.72mm Backer Laminate & Front side 1mm Matt Finish with 2mm PVC Edge Band finish. 128 MAGAZINE HOLDER - 600 x 250 x 1200 Carcass are 16mm MR Ply with 0.72mm Backer Laminate on both Sides, Shutters are 16mm MR ply with One Side 0.72mm Backer Laminate & Front side 1mm Matt Finish with 2mm PVC Edge Band finish. 129 DISPLAY UNIT AT RECEPTION - 1200 x 300 x 600 Carcass are 16mm MR Ply with 0.72mm Backer Laminate on both Sides, Shutters are 16mm MR ply with One Side 0.72mm Backer Laminate & Front side 1mm Matt Finish with 2mm PVC Edge Band finish. 130 LEDGE 5000 x600 x 750 Panels are 16mm MR ply with 1mm Matt Finish on both sides with 2mm PVC Edge Band finish mounted to the wall. 131 4SEATERLEARNINGCENTRETABLE-2000mmx1000mmx750mm -TABLE TOP: 25mm pre laminated particle board with 2mm PVC edge banding. MS 120 LEGS: Pillar are made out of heavy duty CNC cut & bend section of 120 degree which is engineer designed, E250 grate of 2.5mm thick 132 6SEATERLEARNINGCENTRETABLE-2400mmx1000mmx 750mm -TABLE TOP: 25mm pre laminated particle board with 2mm PVC edge banding. MS 120 LEGS: Pillar are made out of heavy duty CNC cut & bend section of 120 degree which is engineer designed, E250 grate of 2.5mm thic 133 READING CHAIR - Lounge Chair Uphostered in EPU Leather. Sleek Four Star Fixed Base With Revolving Function In Warm White Powder Coated Finish. Three Dimensional Lumbar Support Design. Model number SCML-SF30.1. Bosses Cabin or equivalent. 134 ROLLINGCHAIRS-Medium back chair with metal grey back frame, metal grey adjustable PU armrest (4D), moulded foam seat with metal grey shell, STG drive-by-wire mechanism with 4 position locking, polished aluminum alloy five-star base with metal grey PU castors. Model number CHT66SW. Bosses Cabin or equivalent. 135 SINGLESTUDYCHAIR:Multi-Purpose Chair Upholstered In Water Based PU Leather. Cushioned Seat and White Ash Solid Wood Legs. Model number SCMF-XCB33 - Latte Brown. Bosses Cabin or equivalent. 136 LOCKER & FOOTWEAR STORAGE- – 1950x375x470mmPLU main 2 DR numeric lock with envelop slot – 1950x375x470mm. Godrej interio or equivalent. 137 RECEPTIONDESK-1800mmx650mmx 1050mm- Reception Table In Matt White and Oak Laminate. IncludesStorage Cabinet and WireManagement Grommet OnDesk. Top Model number 28ROB003(BCRMB-OB 03). Bosses cabin or equivalent. 138 Seamlessly shift from warm, cozy tones to cool, vibrant whites (also known as tunable white or human-centric lighting) is an advanced JS3 Serial LED Connecting System LED lighting technology that allows users to adjust the color temperature of the light output — from warm to cool — to suit mood, time of day, or functional needs.LED Type: OSRAM SMD 3030Iceil™ Supply of OSRAM 24V LED Module Color Temperature: 2700K to 10000K with Iceil IP67 Drivers CRI: ≥90 – Delivers natural, true-to-life color accuracyMounting: High-performance aluminum rigid PCB– Ensures excellent thermal management and long lifespanConfiguration:– Each block features 4 high-quality LEDs– Optimized light spacing for shadow-free illumination– Viewing Angle: PMMA lens Ultra-wide 160° beam spreadDimmable: No Compatibility:DALI, Tuya Smart App, Alexa, & Google Home. Touch Panel, and RF Remote control optionsPower Consumption:– Only 4-6W per sq.ft– Energy-efficient yet high-lumen outputLighting Quality:– Uniform light diffusion across the stretch ceiling– Suitable for both translucent and printed membrane typesIceil™ Power Supply: Wide Input Range 100-305AC (Class I), Surge Protection with 6KV/4KV, Working temp. -20~ +45°C 20% ~ 90%RH, Metal case IP67, Power factor <0.98LED and Power Supply Warranty: 5 Years or 50,000 Hours (whichever comes first)Certifications: CE & RoHS Certified – environmentally safe and globally compliant Installation of pre-supplied LED lighting fixtures, associated drivers, and control systems, including all necessary mounting, wiring, terminations, and system integration by qualified technicians.The scope includes:Installation of LEDs as per lighting layoutMounting and secure placement of LED drivers and control gear in accessible locationsElectrical connections between LEDs, drivers, and controllers using appropriate cablingTesting of each circuit and commissioning of the full lighting setupRate Includes: Skilled labor, tools, basic fasteners, and all on-site installation efforts.. 139 Iceil™ supplies exclusively premium-grade of European Standard PVC Thermo-Stretchable Membrane, complying with BS1-D0 as per EN 13501-1 and Class A as per ASTM E84-2024 fire safety standards. The membrane is precision-cut to the required shape and size, with perimeter edges high-frequency welded with harpoon inserts. Installation is carried out using a durable aluminium profile framing system, ensuring a seamless, secure, and aesthetic ceiling solutionThickness 0.18 mmWeight 250–300 gsm ± 2%Light Transmission Up to 75% (for translucent type)Width Up to 5 meters (seamless); larger areas joined with invisible seamsStretching Method Thermal installation at ~50–60°C using hot air gas blower Fire Rating BS1-D0, as per EN 13501-1, ASTM E84-2024 Class A Explanation: B = Very limited contribution to fire, s1 = Little or No Smoke Production, d0 = No flaming droplets or particles Moisture Resistance 100% Moisture-proofUV Resistance Yes – does not yellow or degrade indoorsEnvironmental ROHS compliant, Phthalate-free, UL Certified - Tri-O-cresyl phosphate < 50mg per kgCertification Manufactured in ISO 9001:2015 certified factoryWarranty 10 Years (under standard indoor conditions) Installation of pre-supplied Stretch Ceiling System, including site preparation, profile fixing, membrane stretching, and finishing using specialized tools and skilled labor.The scope includesFixing of aluminum/PVC perimeter profiles as per approved ceiling layoutHeating and stretching of the pre-cut stretch ceiling membrane on-siteAlignment, tensioning, and seamless fitting of membrane onto the installed profilesIntegration of cutouts for lighting, sprinklers, air conditioning vents, speakers, etc.Final finishing, cleaning, and handover of installed ceiling areaRate Includes: Skilled labor, installation tools, on-site execution, and necessary accessories for completing the installation of the stretch ceiling. 140 The Iceil Wooden Box is built from durable MR/BWP-grade plywood, featuring a 12mm back board, 18mm vertical sides (150mm height), and dual 8mm flexible plywood layers for curved designs. The 150mm depth accommodates lighting and structural needs.Finish Options: White emulsion or PU-coated interior, or white reflective laminate; exterior customizable per client.Mounting: Reinforced corners, cross supports (wood/MS) every 2 ft, fixed with dash fasteners, threaded rods, or MS supports.Stretch Ceiling Compatibility: Suits Iceil’s PVC Harpoon Profile System with aluminium profiles for welded membranes.Lighting Integration: Base for rigid block LEDs with ventilation slots for heat dissipation. 141 Wall paper 142 Carpet Flooring 143 160A LT Metering Panel - Supply, Installation, Testing and Commissioning of CPRI approved make of panel, cubicle type, Free standing, Wall mounted, single front,14 SWG CRCA sheet steel, enclosed separate compartment for each feeder, front operated, Powder coated, indoor type dust and vermin proof, hinged lockable doors, complete with electrolytic grade copper bus bars,internal wiring, colour coding, ferrules, Panel mounting MS Channels, fasteners, etc., including all associated control wiring. The Breakerof 160A TPN MCCB and 1set of 160/5A CT with TNEB Metering provision and 1nos of 160/5A CT for APFCR . (Rate as per Quotation) 144 Supply and Erection of electrical panels Boards 145 Fabrication, Supply, Erection, Testing and Commissioning of whether proof CRCA sheet steelmade up of 2mm powder coatedMCCB Indoor Type Three Phase Changer Over panel of size (H 2100 X L 2000 X D 300 ) mm with suitable to accommodate 100A 4 pole Three phase Change Over Switch-1No. as incomer for EB Source and as incomer for DG Source, 6nos of 63A 4Pole MCCBs and 4nos of 32A 4Pole MCCBs compartment as O/G supply with the provisions to accommodate Busbar chamber and cable chamber with size of 25x6mm copper busbar 4 runs having three phase Multifunction meter with line indicators and with all necessary accessories with all other connected works etc. The panel made up of 16/18 SWG CRCA sheet steel comprising of 4 sections with separate sheet steel weatherproof and shock proof safety insulation system conforming to IE Rules with IP protection, and with the panel should be painting by powder coating finishing etc.,as complete and making good of the panel with neat finishing. (Switch make : L & T / ABB) panel should be earthing confirming ISI specifications. The panel should be erected on Anchor fastners, bolts and nuts for mounting the Indoor Panel as directed by engineer-in charge/department superior engineers. Including Bus bar support, Cost ofWeldding charges for mounting the panel, Rotary Handle, Spreader Terminal, Multifunction Meter digital type / MFM 5010 LED meter CI 0.5S 146 Fabrication, Supply, Erection, Testing and Commissioning of whether proof CRCA sheet steelmade up of 2mm powder coatedMCCB Indoor Type 50 kVAR panel of size (H 1800 X L 1800 X D 300 ) mm with suitable to accommodate Incomer 1 Nos 63A 4Pole MCCB, 7nos of 25A 4Pole MCCBs with 7% 1-10 kVAR Capacitor banks in compartment as O/G supply with the provisions to accommodate Busbar chamber and cable chamber with size of 25x6mm copper busbar 4 runs having three phase Multifunction meter with line indicators and with all necessary accessories with all other connected works etc. The panel made up of 16/18 SWG CRCA sheet steel comprising of 4 sections with separate sheet steel weatherproof and shock proof safety insulation system conforming to IE Rules with IP protection, and with the panel should be painting by powder coating finishing etc.,as complete and making good of the panel with neat finishing. (Switch make : L & T / ABB) panel should be earthing confirming ISI specifications. The panel should be erected on Anchor fastners, bolts and nuts for mounting the Indoor Panel as directed by engineer-in charge/department superior engineers. Including Bus bar support, Cost ofWeldding charges for mounting the panel, Rotary Handle, Spreader Terminal, Multifunction Meter digital type / MFM 5010 LED meter CI 0.5S 147 VERTICAL THREE PHASE MCB DISTRIBUTION BOARD WITH MCB : Supply and fixingof4way verticalTPMCBsheetsteel Industrial Type TP MCB DB with IP54 Protection of surface type fitted with bus bars and neutral links with1 No. of 63A FP MCB as Incoming and 4 Nos.of32A,10KA Triple Pole MCB in Flush with wall and making good of the concealed portion with earth connection.( Industrial Type TPMCB DB with IP54 Protections) 148 Supply and fixing of 7 segment8 way63A TPN MCB sheet steel distribution board (Higher end) with metal / acrylic doorcover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and separate 4 way provision for accommodating one no. 4 pole incoming 63 A TPN MCB, 10kA, / Isolator and another separate 4 way for accommodating one no. 63 Amps, 30 mA, 4 pole ELCB / RCD (totally 8 ways in one segment) and 24 nos 6-32 A, 10kA, SP MCB / Isolators ( totally 24 nos.) for outgoing in 3 segments with label holder and provision for taking up cable for size not less than 35 sq.mm. withthe following in flush with wall with earth connection only. 149 Supply and fixing of 65 mm dia. (2 -1/2) GI pipe (class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonry pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 90W LED Streetlight fitting with LED (Higher end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED street light fitting and SMC box with PVC unsheathed copper leads from SMC box to fitting and with painting of suitable colour 150 Supply and Fixing of24W Ceiling Lightwith PVC unsheathed copper leads from terminals to the fitting.(Make : Philips/Crompton/Havelles ) 151 Supply and Fixing of11W Bulk Head Lightwith PVC unsheathed copper leads from terminals to the fitting.(Make : Philips/Crompton/Havelles ) 152 Supply of surface-mounted 24W LED wall lights to the ideal solution for a variety of indoor lighting applications. Direct illumination of the wall and surrounding surface, as well as accent lighting for vertical structures. Featuring an aesthetically pleasing, robust construction, these lights are built to withstand all weather conditions, ensuring long-lasting performance and durability • Luminaire body made of extruded aluminium alloy (grade 6063) with die cast aluminium components and non corrosive SS fasteners • Non yellowing UV stabilized translucent polycarbonate diffuser • Luminaire integrated with 24W LED • Die-cast aluminium mounting base for easy installation onto the wall • Surface mounting on wall using hardware after connecting to the power supply • IP : 65, IK : 08 • Cable entries for through-wiring of mains supply cable • Integral constant current power supply • CRI ( Ra) : >80 • Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply • Available CCT : 2700K, 3000K, 4000K, 5700K. Driver Power Supply : Integral, Input Voltage : 230-240Vac, Frequency : 50-60 Hz, Power Factor : ≥0.95, THD : <10%, Surge Protection : 4KV, Efficiency : >85%, Symmetrical Light Distribution.Product Finish options: Pure polyester powder coated RAL 9004 Signal black, RAL 9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. CE & BIS Certified. Inhouse NABL accredited lab. Brand Name : Philips, Product SKU : 919215850004 153 Supply of LED Linear Pendant luminaire is a versatile solution for projects that demand high quality of the lighting system and high visual comfort. With its modular design, the Revo-L can be used as an individual fixture or as a combination of luminaires put together in continuous lines • Luminaire made of extruded aluminium for better thermal management • polycarbonate diffuser for optimum optical performance, • Hexa-cell (Matte Black) secondary reflector • Suitable for surface and suspended mounting • Supplied with standard suspension kit (1metre).• Cable entries for through-wiring of mains supply cable • Integral power supply • Suitable for operation on 240V,50Hz single phase ac supply• Driver Power Supply : Integral, Power Factor : >0.90, THD : <10%, Surge Protection : 4KV-6KV, Efficiency : >85%, IP 44 Rating.• Dimension: 1188 x 36 x 75, 2365 x 36 x 75, 3540 x 36 x 75.• Wattage Options : Upto 40W, Upto 80W, Upto 120W.• Mounting: Pendant Mounting, Pendant Mounting, Pendant Mounting, Surface Mounting, Surface Mounting, Surface Mounting • Product Finish options: Pure polyester powder coated, RAL 9004 Signal black, RAL 9007 Grey aluminium, RAL 9016 Traffic White • CE & BIS Certified • Inhouse NABL accredited lab. Philips SP170P LED25S-6500 PSU W5L113 OD WH Smartbright Linear 154 Supply of Input power : 8W LED Bollard luminaire designed for surface mounted. Symmetrical light distribution. Luminaire madeof extruded aluminium alloy (grade 6063), die-cast aluminium of high corrosion resistance and non corrosive stainless steel fasteners. Translucent polycarbonate diffuser. Pressure die cast aluminium mounting plate Ø100.5mm x 4mm thick with 2 elongated holes 15 x 10 to suit M8 bolts at PCD55 for surface mounting on floor. The base plate have a cable entry hole of 70 x 24 mm dia at the center. Single cable entrance via PG7 cable gland. Protection class IP65. Mechanical resistance IK08. Pure polyester powder coated RAL 9004 Signal black, RAL9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. Available colour temperature 2700K / 3000K / 4000K / 5700K. Colour rendering index (CRI)>80. K-Lite LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor >0.9, THD <10%, Surge protection 2.5KV. Luminaire dimension : 106mm diameter x 565mm height. CE & BIS Certified. Foundation Bolt - 2 Nos of M8 Foundation J Bolt Length 150mm, 2 Nos of (Spring Washers, Plain Washers and Nuts) for each BoltInhouse NABL accredited lab. PHILIPS Bollard BCP100 LED 10W PSU GR L 750mm Solar Light 155 Supply of LED Linear Lighting to suit ceiling / wall is a slim and elegantly designed fixture, suited for varied applications offers a uniform, glareless and soft lighting.Al. Profile Housing Dimension: 1000 x 17 x 8, 2000 x 17 x 8Mounting: Surface Mounting, Product Finish: Anodized Aluminum• Luminaire made of extruded aluminium for better thermal management • PC clear / semi clear matte diffuser for excellent diffused lighting experience throughout the life of the fixture • Designed for mounting on ceiling / wall • Cable entries for through-wiring of mains supply cable • To be used with LED strip & power supply unit of suitable rating. Brand Philips Profile Shine 240 LEDs/m LED Strip | 3000K Warm White | High Brightness Linear Strip for Cove, False Ceiling, Architectural, Ambient Lighting 156 Supply of 24V 2835 Flexible LED Strip, 12W/m, Non-Integral, CCT: 2700K, 4000K, 6500KDimension: 5m / Roll, IP : 67, Brand Name : K-Lite, Code : 7289 or equivalent 157 24V Power supply, IP 67 Rated SMPS suitable for 24V LED Strip lights. Wattage: 150W, 24V Series Waterproof IP67 Power Supply24Vdc 6.25 Amps 150W Power unitDimension: 313 x 43 x 34IP : 67,Brand Name : K-Lite, Code : 8198 or equivalent 158 Supply and fixing of Fans and Air Circulator 159 Supply and fixing of 1200mm (48) sweep AC ceiling fan 5 star rated complete ( Higher end)with 2 module 100W fan step regulator (Higher end)with 2.5 metre down rod with fan clamp, and wiring to the near by point with 1.5 sqmm FRLS , PVC insulated copper wires, including necessaryaccessories and hardwares as required. (SD -563) 160 Supply and fixing of 600mm wall mounting Air circulator and wiring to the near by point with 1.5 sqmm FRLS , PVC insulated copper wires, including necessaryaccessories and hardwares as required. (SD -563) 161 Supply and fixing of 300mm(12)sweep (Heavy duty) AC Exhaust fan complete with necessary wall opening and making good of the wall and wiring to the near by point with 1.5 sqmm FRLS PVC insulated copper wires including necessaryaccessories and hardwares as required. 162 Supply and fixing oflouvers shutter arrangements for 300mm(12)sweep (Heavy duty) AC Exhaust fan complete 163 Supply and laying of following XLPE armoured LTUG cable in a trench/Tray with suitable cable tie tag etc as required. 164 Supply and Laying of 3 1/2 x 50 sq.mm. PVC Al.Armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 165 Supply and Laying of 4C x 16 sq.mm. PVC AL. Armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.Main Panel to DB 166 Supply and Laying of 3C x 2.5 sq.mm. PVC Cu. Armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make goodMain Panel / DB to Street Lights 167 Supplying & Laying 120mm/103.5mm HDPE Pipe as per requirements including excavation & refilling. 168 Supply and fixing of double compression brass cable gland for following Aluminium conductorXLPE insulatedarmoured cable of 1100 V grade with earth connection. 169 Supply and fixing of brass cable gland for3 1/2 Cx 50 Sq.mm PVC LTUGAl. Armoured cable with earth connection 170 Supply and fixing of brass cable gland suitable for4C x 16 PVC Al. Armoured LTUG cable with earth connection. 171 Supply and fixing of brass cable gland for 3C x 2.5 sqmm COPPER cableLTUG cablewith earth connection. 172 Supply and providing cable end termination of the following sizePVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete (copper sockets for copper cables and Alu. Sockets for alum. Cable) 173 Supply and providing cable end termination of3 1/2Corex 50Sq.mm PVC LTUG Al. Armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete. 174 Supply and providing cable end termination of 4 C x 16sq.mm PVC LTUG Al. Armoured cable with necessary aluminium cable sockets by crimping with electrical connection complete. 175 Supply and providing cable end termination of 3C X 2.5 SqmmPVC LTUGCopper cable with necessary copper cable sockets by crimping etc, with electrical connection complete. 176 Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with painting of suitable colour for concealed PVC pipe Plug point ( 8 points / Coil) Higher End (SD-375) 177 Wiring with 2 x 4 sq.mm. (56/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 16A one way module switch and 1 no. 16A 3/2 pin module socket with module front plate with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with painting of suitable colour for Concealed PVC pipe power Plug point ( 8 points / Coil)Higher End (SD-385) 178 Supply and fixing of 25A Flushtype Wall Socket 25A DPMCB complete set for ACPlug inflush with wall with earth connection (For AC Plug) 179 Supply and Run of 2 of 4 sq.mm. (56/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigidpipe Concealed inwall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copperwire and making good of the concealed portion withsuitable colour. ( SD 430 ) 180 Supply and Run of 2 Run x 2.5 sqmm and 1R of 1.5sq sqmm PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable Pvc conduit pipe onconcealed wall and ceiling with continuous earth wire connection with painting of suitable colour. 181 Earthing as per the ISI specification with an earth electrode of 2.10 metre Class B GI pipe of dia not less than 50mm and 2 mtr long earth electrode of low carbon steel rod with 100 micron bonding and 25 kgs of carbon based environment friendly backfill compound and suitable clamp andwithcopper earth plate of size 125mm x 50mm x 6mm with necessary funnelling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonrySD-233 182 Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection 183 Supply and Run of 1 of25.6.25 mm Al. Flat on wall / floor / ground for earth connection. 184 Supply and Run of 1 of25.6.25 mm Cu. Flat on wall / floor / ground for earth connection. 185 Supply, Installation, Testing and commissioning of 40 channel NVR with 4TB HDD * 4nos, Up to 40-ch 8 MP IP cameras can be connected, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by up to 75%, Full channel recording at up to 12MP resolution HD Video Output  HDMI1/VGA1 outputs provided  HDMI1 Video output ) resolution Storage and Playback, Up to 4SATA interfaces and 1 eSATA interface for HDD connection, Support upto 6TB capacity for each HDD, Smart search for efficient playback.(Make: Hikvision/Dahua/Panasonic) 186 Supply of 8MP, Internet Protocol fixed BULLET CAMERA with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behaviour analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse.All including suitable camera stand and accessories. (Make: Dahua/Panasonic) 187 Supply, Installation, Testing & Commissioning of IP Network TDN Low-Light IR Dome Each Cameras, 1/2.8 CMOS,4 MP 2592 x1520 or better , triple stream, Min. Illumination required 0.005 Lux/F2.0 (Color,30IRE), 0 Lux/F2.0 (IR ON), 140dB True WDR, triple stream,3 to 12 mm, F1.4 to 2.8 , MFZ, Backlight Compensation, Highlight Compensation 3DNR, Privacy Mask, Internal/External Smart IR LEDs with up to 50m IR distance, H.265& |MJPEG, Inbuilt Video Analytics: Smart Motion Detection, Intrusion Detection, People Counting, Multiloitering, Face Detection, Line Crossing, Missing Object detection, [Unattended Object Detection. THe camera shall have inbuilt cyber security FIPS Chipset.Audio Stream Full Duplex, 1TB SD card support, IP 67 & IK10, Alarm: 1 In & 1out, PoE, H.265 High Profile and MJPEG, PoE Class . Certifications: ONVIF Profile S,G,T & M compliant, NDAA 889 UL, CE, EN, FCC & RoHS compliant and with all accessories and as per detailed tender specifications. 188 Supply, Installation, Testing and Commissioning of 32 smart LED TV with following specifications a) Full HD 1920 x1080 (4K monitor) b) IPS panel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -3nos n) Built in LAN o) Magic remotep) Dimension 1242 x 724 x 55.1min(37). (Make: Sony/ LG /Samsung). 189 Supply and Clamping of CAT 6 armoured cable in suitable PVCPipe 1 thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem)i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal)IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-TIEEE 802.5 16 MB; ISDN; TPDDI; ATMii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant.Fire Rating: PVC : IEC 60332-1.iii. Conductor - Bare Copper Wireiv. Insulation - Polyethylenev. Twisting - 2 Cores to the pair vi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm. 190 Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point( Point to Point ) Crimping, Testing and arrangement charges. 191 Supply and fixing of POE 24 port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. 192 Supply and Fixing of Rack with Accessories -Higher end 12 U Rack with LNS unit and fan extra for the above rack. 193 Supply and Installation for 2KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2Hours back up 194 PA SYSTEMS 195 Supply,installation, testing and commissioning of 30W High efficiency ABS horn loudspeaker with weather protectin IP 65Max Power : 45 W, Rated power, 30 Watts, Power tapping, 30/15/7.5W-Effective frequency range (-10 db) (-380 Hz to 5 kHz) - SPL at rated power (1 khz) 126 dB- Self extinguishing acc. to UL 94 VO - IP 65 acc. to IEC 60529, safety acc. to EN 60065. (Make - BOSCH) 196 Supply, installaion, testing and commissioning of 240W mixer amplifier with following features : inbuilt bluetooth for audio streaming, sports audio playback from USB pen drive, 4 microphone/line inputs, plus music source input, insert features to use as a pre/power amplifier, Optional 2 tone chime generation for input 1 technical specifications - Frequency response 80 Hz to 18 kHx (+1/-3 dB W - 10 dB ref. rated output) - Distortion <1% @ rated output power, 1 kHz bass control Max +/- 8 dB Treble control max +/- 8 dB. (Make - BOSCH) 197 Supply, installation, testing and commissioning of Goose Mic 198 Supply and installation ofHandheld microphone with a dynamic transducer element that shall be designed for high speech intelligivility. It should have a rugged enclosure is both stylish and easy to use in a wide range of public and sound reinforcement applications. Polar Pattern unidirectional, frequency range 80 hZ to 12 kHz, Sensitivity 1.7mV/Pa +/- dB, Rate out impedance 600 Ohms. (Make BOSCH) (Market rate) 199 Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., asper standard methods and as directed by the Departmental Officers. 200 Supply and Installation for 2KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2Hours back up 201 Supply and erection, testing and commissioning of 2.0 TR (6000K.cal/hr) ABS Split type Air conditioner (3 star rating)confirming to IS : 1391(part-2) 1992 with Admt No.1 fitted withhermetically sealed air compressor operating on refrigerant R-410A suitable for wall mounting for operation on 230V 50 HZsingle phase AC supply inverter technology with capable of thefollowing performinga) Coolingb) Dehumidifyingc) Air circulatingd) Filteringe) Refrigerant pipe lines – 6 mtr lengthThe installation works for the above split type AC units includethe following1. Mounting / fitting indoor and outdoor units at theirrespective locations2. Laying refrigerant pipe line of required length notexceeding 6 meters distance & connecting both units afterdrilling hole/holes in the wall is required, thickness of the coppertubing shall not be less than 0.7 mm3. Installing the section pipe with expanded polythene foamtubing4. Laying drain pipe to throw out the condensate water beingformed within indoor unit5. Leak testing the entire system unit6. Charging refrigerant gas in the unit7. Suitable electrical wiring with to be provided with 2.5sq.mm PVC insulated copper wire between indoor and outdoorunit upto 6 meter length and upto switch within 3 meters oflocation of indoor unit. (Like (Carrier / Voltas / Blue Star /Equivalent) as directed by the department officers 202 Supply and fixing of 5 KVA slim and wall mounting (V Guardmake ) double booster voltage stabilizer for operation on 170-230V 50Hz single phase AC supply capable for 2 TR split ACwith necessary inter connection and earth connection as directedby the departmental officers. 203 LANDSCAPE 204 Supplying of plastic Potted plants Anthurium size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 205 Supplying of plastic Potted plants Bogainvillea size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 206 Supplying of plastic Potted plants Ficus ponda size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 207 Providing & laying spreading & Compacting graded stone aggeragate of size 45mm to 22.4mm, 22.4mm to 2.36mm & 2.36mm to 75 microns to Wet Mix Macadam (WMM) specification including premixing the material with water at OMC in Mechanical mix plant carriage of mixed material by tipper to site, laying in uniform layers with paver in Sub base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density, rate including the cost & conveyence of all materials, labour charges for spreading, watering, rammed & consolidation and other tools & plants employed for the work etc., all complete and as directed by the departmental officers as per MORTH specification 406 IV Revision 208 Supplying and filling with M-Sand well watered rammed, and consolidated complying with relevant standard specifications etc., complete and as directed by the departmental officers. 209 ProvidingandlayingofBlackGraniteCobbleStoneflooringof approvedmake,inallcoloursandshades,laidon20mmthick cementmortar1:4(1cement:4coarsesand),jointingwithgrey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 210 SupplyingandlayingGrassPaverblock M40grade Providingand layingof 63mm thickhighstrengthtypeconformingIS15658- 2006ofrubberizedinterlockingpaverlockinsizeofminimum compressivestrengthof40N/mm2inuniformshapeofapproved maketobelaidinflurringbonepatternwithsandcushionbelow theuniformshapofapproved nonskittingsurfaceinthetopand therateincludinglevellingthebasepreparationof paversassub base,sandcushion150mmthicklaying outofpavementcutthe piecestofixtheedgevibringthepavers,sweepingtranporting loadingunloadingoflayingpaverblockasperstandard specification,.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
25.
Housing Urban and Rular Development #10217851 Price Bid
Tender For Redevelopment Of Murasoli Maran Park North Located At Perambur.; 1 Dismantling plain cement concrete work and clearing the debris etc., complete as directed by the engineer-in-charge 2 Dismantling GI Sheet with posts 3 Dismantling the existing brick or stone masonry work in cement mortar under 3m high including clearing away and carefully stacking materials useful for re-use etc., complete as directed by the engineer-in-charge 4 Dismantling R.C.C.works,carefully clearing away the debris as directed during execution. The dismantling of concrete as per PWD schedule of rates are to be adopted wherein a part part of the concrete only is to be dismantled and the remaining part of the concrete has to be retained structurally safe. 5 Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. 6 Narrow Foundations for building & culvert - First Depth Upto 2m 7 Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification. 8 Refilling with excavated earth in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification. 9 Supplying and filling with earth up to 10 Km for foundation and basement, etc., including watering and consolidating, etc., complete complying with standard specifications and as directed by the engineer-in-charge 10 Construction of Wet Mix Macadam 150 mm compacted thickness in two layers by providing laying , Paving , and compacting of aggregate gradation satisfying to Table 400-13 of MORTH and satisfying he physical paraemeteres as per MORTH Table 400-12, mixing in a Wet Mix Plant of 200 tonne capacity at OMC , carriage of mixed material to work site and laid in sensor pavers tc the required line and grade as per the drawing and compacted with vibratory roller of 8-10 tonne to achieve the desired density of 98% of Maximum dry density and as per the direction of the Engineer In-Charge of work 11 Supplying and filling of well gravel by lorry in basement filling including conveyance loading and unloading charges and all other incidential charges filling laying watering and consolidation etc., complete as directed by the Dept., Officers with standard specification. 12 Supplying and filling in foundation, basement, etc with Crushed Stone sand filling in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 13 Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 14 Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid). 15 Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid). 16 For plane surfaces such asrectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc. 17 For column footing plinth beam bed blocks templates staircase, steps piers, raft beam, raft slab etc. 18 Providing and laying in position, Standardised Concrete Mix M-25 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kg/mᶾ and maximum water cement ratio of 0.50, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers.The coarse and fine aggregates to be used should comply with the requirements of IS Standards.(No separate payment will be made by the Department for the excess usage of materials). 19 Foundation and Basement 20 For Ground Floor 21 Providing and laying in position, Standardised Concrete Mix M-30 Grade using In-situ Concrete batching plant/ Ready Mix Concrete (RMC) adopting weigh batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 400 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including Conveyance of concrete from batching plant to Work site, Electricity charges and other works & labour cost involved for concrete production, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). 22 For Foundation and basement 23 For Ground floor 24 Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification.(Contractor has to make his own arrangements for the supply of steel and binding wire) 25 Supplying,fabricating and errectingStainless steel (Grade SS316) Channel fabricated and connecting with plates of 6 mm thick. The rate inclusive of cost of Stainless steel Channel section, plate, cleat angle, necessary bolts and nuts, labour charges for welding, fabricating & erectingetc., complete and as directed by the departmental officers. 26 Random Rubble in Lime Mortar etc., Complete complying with standard specification and as directed by the Departmental Officers. 27 For Foundation and basement 28 For Ground floor 29 Brick work in Cement Mortar 1:3 using best quality of Second Class Ground Moulded Chamber Burnt Bricks 9 x 4-3/8 x 2-3/4 for foundation and basement including curing, etc., complete complying with standard specifiction. 30 For foundation & basement 31 In Ground floor 32 Outer Plastering with Cement Mortar 1:4 (One cement and Four sand), 20mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. 33 Painting two coats of newly plastered wall surface with ready mixed Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. 34 Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) 35 Paving the floor/dadooing with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Jet black with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification 36 Paving the floor/dadooing with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Flamed steel grey granite slab with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification 37 Nosing the granite slab - single nosing as directed by the engineer-in-charge 38 Supplying and fixing of M.S.grill of approved design for grill gate, grill work to doors and windows openings ramp etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including priming coat of best approved quality red oxide primer etc., complete complying with standard specification. 39 Providing and fixing of Aluminium Composite Panel (ACP) 4 sided having 50 x 25 x 1.50mm frame work vertical and horizontals out of specially designed extruded sections withstand wind pressure of 180 Kg/sq.m and fabricated fixed at all level elevation and heights.The extruded section cutting and fixing required space extruded section shall be of 6063 and alloy of BSH 9 confirming T is – 63400 rate shall included to fix the main frame with necessary clamps, fasteners, bolt nuts etc.The main frame of extruded section shall be of 22843 & 22739 (H9) grade conforming to BS 4174 (or) IS 8147.Rate shall included 4mm thick ACP sheet (0.25 + 3.5 + 0.25) alstrong or equivalent fixing with spacer tape and the ACP sheet bounded with special type structural sealant of dow corning 789 or equivalent in dust free conditions the gaps between ACP sheet to be filed with whether sealant and backer rod or 12mm foam sheet to ensure water and air tightness in all complete complying with standard specification as directed by the departmental officer 40 Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification 41 Art work as per the direction of department official, over Oil Painting with first class quality and approved colour including a priming coat with thorough scrapping clean removal of dirt., etc., complete and including necessary plaster of paris, putty, etc., wherever required (Relevent ISI STD), excluding putty works. 42 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between.The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete.The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete 43 Providing granolithic floor finish of 50 mm thickness with plain cement concrete 1:2:4 (One Cement, Two sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panellingwherever necessary and as directed by the departmental officers) 44 SOLID BLOCKS 40X20X20 CM Supplying and fixing Solid Blocks of following size confirming to S.S. 2145-1965 (including jam blocks closers etc.) made in CC 1:3:6 (One Cement Three Sand and Six HBSJ 6 mm) in CM 1:5 (one cement and five sand),for masonry wall partition wall including curing neat finishing etc. complete 45 Best Tiled roofing with Mangalore tiles, set in lime mortar 1:2 over flat tiles (15cm x 15cm x 12mm) and including teakwood reepers (50 x 12 mm), etc., complete as per standard specifications and directed by the engineer-in-charge 46 Supply and fixing ofPortable Store room of size8x8x7 and type PUF with following specifications:Structure: The supporting column at corners is made out of SHS 70mm pipe welded between The top and Base frames. The structural base frame work made out of 2mm thick SHS 70 pipe as peripheral frame work and RHS 60 x 40, RHS 60 x 40 & SHS 25 as intermediate support to Form a grid of 600mm x 600mm both ways to support the flooring. The structural Top frame work made out of 2mm thick RHS 60 x 40 pipe as peripheral frame work and RHS 60 x 40 & SHS 40 as intermediate support at an interval of 1200mm to support the roof. with 150mm Extended Leg in all Corners (Column)Flooring: The 18mm Cement particle Board place on the top of Bottom frame and Proper fasteners with Vinyl flooringRoof: The roof panels shall be made of TCT Pre coated Profile steel sheets on both side and inner portion made of PUF. Total thickness of roof panel shall be 30mm. With single side slope of roofWall:The Wall panels shall be made of TCT Pre coated Profile steel sheets on both side and inner portion made of PUF. Total thickness of roof panel shall be 50mm.Door:Standard Puf panel Door-1 No with Pad Lock out side and Altrop insideElectrical: Switch and Socket-2No’s, Tube light-1No’s inside, outside Bulk head fittings 1No.Complete, etc., as directed by the engineer-in-charge 47 Supply and fixing of Portable Security Cabin of size 6x6x7 and type PUF with following specifications:Structure:The supporting column at corners is made out of SHS 70mm pipe welded between The top and Base frames. The structural base frame work made out of 2mm thick SHS 70 pipe as peripheral frame work and RHS 60 x 40, RHS 60 x 40 & SHS 25 as intermediate support to Form a grid of 600mm x 600mm both ways to support the flooring. The structural Top frame work made out of 2mm thick RHS 60 x 40 pipe as peripheral frame work and RHS 60 x 40 & SHS 40 as intermediate support at an interval of 1200mm to support the roof. with 150mm Extended Leg in all Corners (Column)Flooring: The 18mm Cement particle Board place on the top of Bottom frame and Proper fasteners with Vinyl flooringRoof: The roof panels shall be made of TCT Pre coated Profile steel sheets on both side and inner portion made of PUF. Total thickness of roof panel shall be 30mm. With single side slope of roofWall:The Wall panels shall be made of TCT Pre coated Profile steel sheets on both side and inner portion made of PUF. Total thickness of roof panel shall be 50mm.Window:1mx1m Aluminium Glass Sliding window-3No’s.Door:Standard Puf panel Door-1 No with Pad Lock out side and Altrop insideOthers:Writing Pad-1 No.Electrical: Switch and Socket-2No’s, Tube light-1No’s inside, outside Bulk head fittings 1No., Wall mounted fan - 1 No.Complete, etc., as directed by the engineer-in-charge 48 Supplying and fixing of Semi polished granite stone bench of 5 feet length with 1.5 feet width, backrest 2 feet height, seating height of 1.5 feet from floor level and of material thickness 50 mm, including cost of materials, labours and conveyance charges, etc., complete, as directed by the engineer-in-charge 49 Supplying And Fixing of Rubber Moulded Grey Premium Concrete Kerb of Size 450X125X300mm Using M30 Concrete. The Concrete Shall Be Moulded By Table Mount Vibrated With Polypropylene Fibers At 5% And Curing Compound. The Rate Shall Include Cost of Materials Transportation Loading Unloading Charges And All Taxes Including Necessary Earth Work Pointing With cm. 1:3 To Full Depth Curing Thread Lining Etc Complete 50 Supplying and laying hydraulic pressed monolithic natural grey colour cement concrete inter locking paver block of 63mm thick, in cement concrete 1:2:4 (one cement, two sand, four aggregate) using difference design and with stand for pressure of 150 - 200 kg/m2 over the existing sand cushion by using earth rambers and also vibratting the concrete blocks often laying using plate vibrators etc, complete as directed by the departmental officers. 51 Paving the floor/dadooing with best approved quality Rough Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Jet black with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification 52 Painting with two coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) 53 Supplying and laying Pebble Flooring walkpath (8-shape) of walkpath area of 32 Sqm in cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and pointedwith same colour of cement etc., complete as per standard specification 54 Providing and laying EPDM Flooring (Ethylene Propylene Diene Monomer) of 36mm thickness with proper laying materials of approved sample as per design / drawing laid compacting, levelling to required slope, finishing neatly. The rate including cost of all materials, labour charges, transportation, loading & unloading and all incidentals etc. complete complying with relevant standard specification and as directed by the Engineer-in-charge. 55 Cut Stone in Lime Mortar etc., Complete complying with standard specification and as directed by the Departmental Officers. 56 Scaffolding charges for Vimanams and Gopurams with casurina posts coconut or palm trees wherever necessary for main, form work and providing with net lawn / PVC mesh coverings, providing ladder arrangements, country wood plank for working, inspection etc. complete, hire charges only for erection, maintenance and removing the same on completion of the work. 57 Upto 15 58 Upto 25 59 Supplying and laying Stone for gopuram and Thoon the rate inclusive of cost of materials, conveyance and labour charges, lifting charges etc., 60 Charges for Designing the gopuram stone like ubabeedam pathmajagathi, ubabeedam kandam and ubabeedam kabothagam, Sthambavari, Kabothaga Vari etc., 61 Ubabeedam Pathma jagathi 62 Ubabeedam - kandavari/ thaddi vari set 63 Ubabeedam - kabothagam 64 Adhirstanam - padma jagathi vari 65 Adhirstanam - kandavari/ thaddi kudam set 66 Adhirstanam - Kabothagam 67 Adhirstanam - Kumuthaga jagathi 68 Adhirstanam - jagathi 69 Adhirstanam - kumuthaga vari 70 Sthambavari 71 Thadikudam set 72 Veerakandagam pothigai 73 Uthiram 74 Kabothagam 75 Viyalavari 76 Thoon 77 Simmam 78 Laying cut stone flooring using new stones 0.60 x 0.60 m not less than 10 cms thick. The Rate inclusive of labour charges, materials, and coveyance charges etc., 79 ELECTRICAL WORKS 80 TNEB METERING BOARDMetering Panel - Supply, Installation, Testing and Commissioning of CPRI approved make of panel, cubicle type, Free standing, floor mounted, single front,14 SWG CRCA sheet steel, enclosed separate compartment for each feeder, front operated, Powder coated, indoor type dust and vermin proof, hinged lockable doors, complete with electrolytic grade copper bus bars,internal wiring, colour coding, ferrules, Panel mounting MS Channels, fasteners, etc., including all associated control wiring. 1set of 160A with TNEB Metering provision. 81 Supply and fixing of 125A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double break on suitable angle iron frame work with MS cable entry boxes with PWD earthing. 82 Fabrication, Supply, Erection, Testing and Commissioning of whether proof CRCA sheet steel powder coated MCCB Indoor Panel Board, made up of 2mm powder coated, including bus bar provision of double door with industrial lock with Multifunction Meter 1no andMain 1no 125A 4Pole MCCB I/C, 2nos 100A 4Pole MCCB,2nos of 63A 4Pole MCCBs and 2nos of 32A 4Pole MCCBs for O/Gwith suitable copper bus bar (33x6mm) having three phase Multifunction meter with line indicators for erecting the indoor panel board complete etc., The above panel board is to be erected on Anchor fastners, bolts and nuts for mounting the Indoor Panel etc. complete. 83 VERTICAL THREE PHASE MCB DISTRIBUTION BOARD WITH MCB :Supply and fixingof8 way verticalTPMCBsheetsteelTPMCB DB with IP42 Protection of surface type fitted with bus bars and neutral links with1 No. of 40A FP MCB as Incoming and 8 Nos.of 32A,10KA Triple Pole MCB in Flush with wall and making good of the concealed portion with earth connection. (TPMCB DB with IP42 Protections) 84 VERTICAL THREE PHASE MCB DISTRIBUTION BOARD WITH MCB :Supply and fixingof8 way verticalTPMCBsheetsteelTPMCB DB with IP42 Protection of surface type fitted with bus bars and neutral links with1 No. of 40A FP MCB as Incoming and 8 Nos.of 32A,10KA Triple Pole MCB. The MCB DB and MCB should be with ISI mark.The above Three Phase VDB is to be erected on masonary pedestal 2nos including earth work excavation, for a depth of 2feet, PCC 1:2:4of 800mm depth, 2.5feet height concreate bed, plastering, painting etc., with earth connection. (TPMCB DB with IP42 Protections) 85 Supplyandfixingof 7segment 8way40 AFP MCBsheet steel distributionboard(Higherend)withmetal/acrylicdoor coverflushtype /surface type fittedwith busbarsandneutral linkswith single /threephase MCB outgoings and separate 4 way provision for accommodating one no. 4 pole incoming 40 A FP MCB, 10kA, and another separate 4 way for accommodating one no. 40 Amps 4 pole MCB/ ELCB / RCD (totally 8 ways in one segment) ( 3x6ways in each segment ) and Seperate Provision for MCB / Isolators (totally 18nos) for sub incomers in 3 segments with label holder and provision for taking up cable for size not less than 35 sq.mm. withthe following in flush with wall with earth connection only. i.40A 4Pole MCB - 1no.ii.32A 2Pole MCB - 3nos.iii.6A to 32A SP MCB - 24nos.The MCB DB and MCB should be with ISI mark.The above Three Phase 8way CDB is to be erected on masonary pedestal 2nos including earth work excavation, for a depth of 2feet, PCC 1:2:4of 800mm depth, 2.5feet height concreate bed, plastering, painting etc., with earth connection. 86 Supplyandfixingof 7segment 12way40 AFP MCBsheet steel distributionboard(Higherend)withmetal/acrylicdoor cover fitted with busbarsandneutral linkswith single /threephase MCB outgoings and separate 4 way provision for accommodating one no. 4 pole incoming 40 A FP MCB, 10kA, and another separate 4 way for accommodating one no. 40 Amps 4 pole MCB/ ELCB / RCD (totally 8 ways in one segment) ( 3x6ways in each segment ) and Seperate Provision for MCB / Isolators (totally 18nos) for sub incomers in 3 segments with label holder and provision for taking up cable for size not less than 35 sq.mm. with the following : i.40A 4Pole MCB - 1no.ii.32A 2Pole MCB - 3nos.iii.6A to 32A SP MCB - 36nos. The MCB DB and MCB should be with ISI mark.The above Three Phase 8way CDB is to be erected on masonary pedestal 2nos including earth work excavation, for a depth of 2feet, PCC 1:2:4of 800mm depth, 2.5feet height concreate bed, plastering, painting etc., with earth connection. 87 Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 6 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End 88 Supply and laying of following XLPE armoured LTUG cable in a trench / Tray with suitable cable tie tag etc as required. 89 SupplyandLayingof3 1/2Cx70sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 90 SupplyandLayingof3 1/2Cx35sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 91 Supply and Laying of 4C x 16 sq.mm. PVC armoured LTUG cable in suitable sizeHDPEpipeinatrenchto beexcavatedatadepthof0.75metreand refilling the earth to make good. 92 Supply and Laying of 4C x 10 sq.mm. PVC armoured LTUG cable in suitable sizeHDPEpipeinatrenchto beexcavatedatadepthof0.75metreand refilling the earth to make good. 93 Supplying and Laying of 3C X 4 sqmm Flexible Multicore Cable manufactured with electrolytic grade flexible copper with FRLS conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 in suitable size of HDPEpipeinatrenchtobeexcavatedatadepthof0.75metreand refilling the earth to make good. 94 Supplying and Laying of 3C X 2.5 sqmm Flexible Multicore Cable manufactured with electrolytic grade flexible copper with FRLS conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 in suitable size of HDPEpipeinatrenchtobeexcavatedatadepthof0.75metreand refilling the earth to make good. 95 Supply and Clamping of 4C x 16 Sq.mm PVC armoured LTUGaluminium cableonpostoronwallwithMS-clamps,saddles,plugs,screwsetc.,complete including transport charges of UG cable. 96 Supply and Clamping of 4C x 10 Sq.mm PVC armoured LTUGaluminium cableonpostoronwallwithMS-clamps,saddles,plugs,screwsetc.,complete including transport charges of UG cable. 97 Supply and fixing of double compression brass cable gland for following Aluminium conductorXLPE insulatedarmoured cable of 1100 V grade with earth connection. 98 Supply and fixing of brass cable gland for3 1/2 Cx 70 Sq.mm PVC LTUG armoured cable with earth connection. 99 Supply and fixing of brass cable gland for3 1/2 Cx 35 Sq.mm PVC LTUG armoured cable with earth connection. 100 Supply and fixing of brass cable gland suitable for 4C x 16 Sq.mm PVC armoured LTUG cable with earth connection. 101 Supply and fixing of brass cable gland suitable for4C x 10 PVC armoured LTUG cable with earth connection. 102 Supply and providing cable end termination of the following sizePVC LTUGaluminiumarmouredcablewithnecessaryaluminiumcable socketsbycrimpingetcwithelectricalconnectioncomplete(copper sockets for copper cables and Alu. Sockets for alum. Cable) 103 Supply and providing cable end termination of 3 1/2Corex 70 Sq.mm PVC LTUG Aluminium armouredcablewith necessary aluminium cablesockets by crimping etc., with electrical connection complete. 104 Supply and providing cable end termination of 3 1/2Corex 35 Sq.mm PVC LTUG Aluminium armouredcablewithnecessary aluminium cablesockets by crimping etc., with electrical connection complete. 105 Supply and providing cable end termination of 4 C x 16sq.mm PVC LTUG Aluminiumarmouredcablewithnecessaryaluminiumcablesocketsby crimping with electrical connection complete. 106 Supply and providing cable end termination of 4 Cx10sq.mm PVC LTUG Aluminiumarmouredcable withnecessaryaluminiumcable socketsby crimping with electrical connection complete. 107 Supply and fixing of Timer Extended Product Type AD1CO-R-15m, Long Description Analog time switch, daily proramming, 1 channel CO, 15 minutes switch, with reserve, Function : Daily, Maximum Load Capacity : Resistive load 16 A Inductive Load 4 A,Power Supply : (-15%..+10%) 230 V AC, Contact Type : Change-Over (CO), Meter Type : Electromechanical , Options Provided : With running reserve, Battery Chemical Composition : Nickel-Metal Hydride, Battery Life : 150 hour, Battery Type : Button Cell, Battery Weight : 0.004 kg, Number of Batteries : 1, Rated Operational Voltage : 230 V, Operational Voltage : Maximum (Incl. Tolerance) 195 V AC, Maximum (Incl. Tolerance) 253 V AC, Rated Frequency (f) : 50 - 60 Hz, Maximum Switching Power : 4000 W, Low Consumption Lamp (CFL) 2500 W LED 900 W, The rate is inclusive of necessary connecting accessories etc., complete. Contactor Extended Product Type AX65 - 30-11-80, CAD Dimensional Drawing : 2CDC001079B0201, Number of Main Contacts NO : 3, Number of Main Contacts NC : 0, Number of Auxiliary Contacts NO :1, Number of Auxiliary Contacts NC : 1, Rated Operational Power AC-3 (Pe) (415V) 37 kW, General Use Rating UL/CSA : (600 V AC) 90 A, Low Voltage Products and Systems → Control Products → Contactors → Block Contactors → AX Contactors → AX65 ( Make : ABB, Product ID 2CSM208151R1000, TIMER ), ( Make : ABB, Product ID 1SBL371074R8011, CONTACTOR ) 108 Indoor and Outdoor Lights 109 Supply & Installation of Customised 60W Juno-Column light luminaire designed for surface mounted. Shielded light distribution. Luminaire made of spun aluminium with extruded aluminium alloy (grade 6063) and non corrosive stainless steel fasteners. Translucent acrylic diffuser. Pressure die cast aluminium mounting plate 250mm dia round x 12mm thick with 4 elongated holes 38 x 19 to suit M16 bolts at CC 140 with pure polyester powder coating.The base plate have a cable entry hole of 65mm dia at the center. This mounting plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation. Protection class IP65. Mechanical resistance IK08. Pure polyester powder coated RAL 9004 Signal black, RAL9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. Available colour temperature 2700K / 3000K / 4000K / 5700K. Colour rendering index (CRI)>80. LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >88%, Power factor >0.95, THD <10%, Surge protection 6KV. Luminaire dimension : 600mm dia round x 3500mm height. CE & BIS Certified. Inhouse NABL accredited lab with LM 79 Testing facility. The rate is inclusive of Foundation Bolt - 4 Nos of Necessary M16 Foundation workJ Bolt Length 300mm, 2 Nos of (Spring Washers, Plain Washers and Nuts) for each Bolt - Suitable for Juno Column Lighting. ( Make : Model No. KL7034 or equivalent ) 110 Supply & Installation of Customised 36W pole top Juno Midi luminaire. Beam angle 120°. Luminaire made of spun aluminium, integrated with extruded aluminium pipe along with pressure die cast aluminium base through supporting arms made fo gravity die cast aluminium and non corrosive stainless steel fasteners. Diffuser placed into the provision formed on the pheriphery of the bottom cover. Translucent acrylic diffuser. Suitable for mounting on Ø50mm OD pipe. Protection class IP65. Mechanical resistance IK07. Pure polyester powder coated RAL 9004 Signal black, RAL 9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. Available colour temperature 2700K / 3000K / 4000K / 5700K, Colour rendering index (CRI)>80. LIGHT LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >85%, Power factor >0.95, THD <10%, Surge protection 4KV. Luminaire dimension : 420mm diameter x 430mm height. CE & BIS Certified. Inhouse NABL accredited lab. ( Make : Model No. KL 5380 or equivalent. ) 111 Supply and fixing of Outdoor Termination PVC Box. The cost is inclusive of gland, lugs and termination) with all fixing accessories etc., complete. 112 Supply & Installation of 50W LED compact and robust flood light luminaire designed to provide uniform illumination in open spaces. Beam angle 10°. Extruded aluminium hood cover integrated with die-cast module and extruded aluminium alloy tube (grade 6063), excellent thermal management heat sink & polycarbonate optical lens. Adjustable clamp made of stainless steel (2mm thickness) to facilitate proper aiming of the luminaire at desired angle. Pressure die cast aluminium mounting plate Ø100.5 x 4mm thick with 2 elongated holes 15 x 10 to suit M8 bolts at PCD 55 with pure polyester powder coating. This mounting plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation. Cable entrance via PG9 cable gland. All external screws are made of stainless steel. Protection class IP65. Mechanical resistance IK09. Pure polyester powder coated RAL 9004 Signal black, RAL9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. RGBW, Colour rendering index (CRI)>80. K-Lite LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >85%, Power factor >0.90, THD< 10%, Surge protection 6KV. Luminaire dimension : 166mm diameter x 168mm width x 584mm height. CE & BIS Certified. Inhouse NABL accredited lab. ( Make : K-LiTE KL 4331or equivalent ) 113 Supply & Installation of 12W LED surface mounted compact spot light designed to provide directional light. Beam angle 15° / 25° / 40°. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive stainless steel fasteners. Clear toughened glass of 4mm thickness. Pressure die-cast aluminium surface mounting base. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Swivel range of 0° - 90°. Single cable entrance M10 cable gland. Protection class IP66. Mechanical resistance IK07. Pure polyester powder coated RAL 9004 Signal black, RAL9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. Available colour temperature 2700K / 3000K / 4000K / 6500K, Colour rendering index (CRI)>80. High Quality LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor >0.95, THD <10%, Surge protection 4KV.Luminaire dimension : 113mm length x 84mm width x 117mm height. CE & BIS Certified. Including accessory Visor. Inhouse NABL accredited lab. ( Make : Model No. KL 4268 or equivalent. ) 114 Supply & Installation of 12W LED spike mounted compact spot light designed to provide directional light.Beam angle 15° / 25° / 40°. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive stainless steel fasteners. Clear toughened glass of 4mm thickness. Surface mounting spike made of polypropylene. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Swivel range of 0° - 90°. Single cable entrance M10 cable gland. Protection class IP66. Mechanical resistance IK07. Pure polyester powder coated RAL 9004 Signal black, RAL 9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. Available colour temperature 2700K / 3000K / 4000K / 6500K, Colour rendering index (CRI)>80. LIGHT LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor >0.95, THD <10%, Surge protection 4KV.Luminaire dimension : 113mm length x 100mm width x 451mm height. CE & BIS Certified. Including accessory Visor. Inhouse NABL accredited lab. ( Make : Model No. KL 4267 or equivalent. ) 115 Supply & Installation of 16W LED Bollard luminaire designed for surface mounted. Symmetrical light distribution. Luminaire made of extruded aluminium (grade 6063), pressure die-cast aluminium components of high corrosion resistance and non corrosive stainless steel fasteners. Reflector system made of spun aluminium (powder coated white). Clear polycarbonate diffuser. Pressure die cast aluminium mounting plate 167mm diameter x 4mm thick with 4 elongated holes 20 x 14 to suit M12 bolts at PCD 110 for surface mounting on floor. The base plate have a cable entry hole of 75mm dia at the center. This mounting plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation. Single cable entrance via PG7 cable gland. Protection class IP65. Mechanical resistance IK10. Pure polyester powder coated RAL 9004 Signal black, RAL9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. Available colour temperature 2700K / 3000K / 4000K / 5700K. Colour rendering index (CRI)>80. High Quality LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor >0.95, THD <10%, Surge protection 3KV. Luminaire dimension : 166mm diameter x 970mm height. CE & BIS Certified. Inhouse NABL accredited lab. The rate is inclusive ofFoundation Bolt - 4 Nos of M12 Foundation J Bolt Length 300mm, 2 Nos of (Spring Washers, Plain Washers and Nuts) for each Bolt with suitable civil foundation etc., complete. ( Make : Model No. KL 5565 or equivalent. ) 116 Supply & Installation of 6W LED compact and robust wall recessed luminaires for illuminating walls and stairs. Forward asymmetrical light distribution. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive A2 stainless steel fasteners. ABS plastic installation housing for preparing the recess opening in wall / stairs. Clear acrylic diffuser. Single cable entrance via M10 cable gland. Protection class IP65. Mechanical resistance IK09. Pure polyester powder coated RAL 9004 Signal black, RAL9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. Available colour temperature 2700K / 3000K / 4000K / 5700K, Colour rendering index (CRI)>80. High Quality LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor >0.90, THD <10%, Surge protection 2KV. Luminaire dimension : 130mm length x 87mm width x 76mm height. Luminaire installation in a recessed opening cut-out dimension : 124mm length x 83mm width x 70mm height. CE & BIS Certified. Inhouse NABL accredited lab. ( Make: Modle No. KL 2747 or equivalent. ) 117 Supply & Laying ofNiva 15 surface mounted compact flexible linear LED lightingwith system wattage of 9W/m. Beam angle 120° diffused. Luminaire housing and diffuser made of silicone, UV proof for true outdoor application. High light transmittance, environmental silicone material. Top bendable. Cut-able for flexible application. Even light distribution & no hot spots. Aluminium mounting profile / Flexible mounting channel for surface mounting on ceiling / wall / floor. Protection class IP67. Mechanical resistance IK08. Available colour temperature 3000K (Other CCTs on request), Colour rendering index (CRI)>80. Operating temperature range is from -15°C to +50°C. Constant voltage non integral power supply at 24Vdc assures safety. Luminaire dimension : 1000mm length x 15mm width x 15mm height. KL 8399 - Mounting Chain Included. Inhouse NABL accredited lab. ( Make: LIGHT ID : 3396 or Equivalent. ) 118 Supply and fixing LED Control Driver of 24V Series Waterproof IP67 Power Supply 24V DC, 6.25 Amps 150WDimension: 313 x 43 x 34. The rate is inclusive of labour charges etc., complete.( Make : KL-8198 ) 119 Supply & Installation of 7M height Brussel pole made of circular mild steel pipe of two section (grade YST 210) which is fabricated using 139.7mm diameter x 3.6mm thick base section with height of 2000mm, the top section is 88.9mm diameter x 2.9mm thick with minimum height of 4978mm. & 4 Nos. of Die-cast aluminium mounting clamp (126mm dia x 60mm height) for fixing 8 Nos. of 50Wflood light luminaires. Pole mounted flood light luminaires. Extruded aluminium hood cover integrated with die-cast module, excellent aluminium heatsink for thermal management with vertical fin design for longer life of the LEDs. Bracket to facilitate proper aiming of the luminaire at desired angle. Protection class IP65 optical compartment with polycarbonate optical lens and Mechanical resistance IK10. The luminaire provided with beam angle 10° / 28° / 45° (Symmetrical light distribution). Available colour temperature 2700K / 4000K / 5700K, colour rendering index (CRI)>/=80. K-Lite LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >85%, Power factor >0.95, THD< 10%, Surge protection 6KV. electrical Class I wattage 50W ± 10%. High power LED (Make: Nichia) with Macadam 120 Inhouse NABL accredited lab. The pole is to be provided with a surface mounting suitable base plate 300 mm square x 16 mm thick steel of grade E250 to IS 2062 : 2011. All dimension are within +/- 5% tolerance. Pole section welded by certified welders using high end MIG welding processes. 3Nos. of PDC aluminium service door 348mm height x 110mm width shall be provided with the company logo embossed on the bottom of the door and safety rope. The control gear tray is prewired with 2.5 Sq.mm cable, 6A SP MCB and 32A Ramanuj stud type 4 way terminal block for loop-in / loop-out arrangement, 5A 2 Way terminal connector and provision for earthing. Any other internal cables and connections shall not be covered in the scope of supply. The mild steel mounting base plate. The mounting plate provided with 4 elongated holes 48 x 24 to suit M20 x 500mm bolts of grade 4.6 at CC 215 for alignment of the pole. The base plate have a cable entry hole of 70mm dia at the center. This mounting steel plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation. After fabrication, entire pole is shot blasted (Inhouse). The pole is coated with zinc rich primer & pure polyester powder coating or epoxy zinc phosphate primer and finished using environmentally stable polyurethane based paint (coating thickness 60-80 microns). The Pole shall be provided with Graphite grey / Anthracite grey / Black as standard colour options. ( Make: K-LiTE ID : 1063 or Equivalent. ) 121 Supply & Instalaation of 60W Cylin Mega Compact and efficient ceiling mounted down lighters. High protection class & lumen output makes it versatile solution for both indoor & outdoor applications• Luminaire made of pressure die cast aluminium with non corrosive stainless steel fasteners. IP 65• Clear toughened glass.• Silicone gasket.• Polycarbonate optical lens.• Surface mounting on ceiling using hardware after connecting to the power supply.• Cable entries for through-wiring of mains supply cable.• Integral constant current power supply• CRI (Ra) : >70• Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply.• CCT : 2700K, 3000K, 4000K, 5700KMandatory CE Marking, BIS Certification, LM 79 report, IP, IK Report from NABL accredited Lab. ( Make: K-LiTE, Model No.KL 3628) or equivalent. 122 SupplyandFixingof 40W4 LEDTubewith Light fittingTW round blockfixing ceiling or on wall withPVCunsheathed copper leadsfrom terminalsto the fitting. (Make : Philips / Crompton / Havelles ). 123 supply and fixing of 1200mm (48) sweep AC ceiling fan complete ( Higher end) with 2 module 100W fan step regulator (Higher end) with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18). 124 Supplyandfixingof375mm (15) sweep(Heavyduty)ACExhaustfan completewithnecessarywallopeningandmakinggoodofthewalland wiring to the near by point with 1.5 sqmm FRLS PVC insulated copper wires including necessaryaccessories and hardwares as required. 125 Supplyandfixingof louversshutterarrangementsfor300mm(12)sweep (Heavy duty) AC Exhaust fan complete. 126 Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling withModule GI switch box in flush with wall with 6A one way module switch with module front plate continuous earth wire connection by 1 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour for PVC concealed light (6 points per coil) (for rooms like bath, toilet & pumproom, etc.). 127 Supply and fixing of 2Nos 6A modular (2 in one 3pinsocket)wall socket with control switches and 1 No. 6A/16A 3pin switched socket (16A Switch and Socket combined) with suitable MS modular box covered with Modular 9 module whiteplate on wall with earth connection (For cctv monitor socket) 128 Supply and fixing of 1 No. 6A/16A 3pin switched socket(16A Switch and Socket combined) with control switch (Crabtree / Legrand / Hager / Equivalent) in suitable MS modular Box covered with Modular 3module whiteplate in wall with earth connection. 129 Supply and installation maintenance free GI Earthing System comprising of 50mm dia and 2 mtr. long earth electrode oflow carbon steel rod with 100 micronbondingand25kgs.ofcarbonbasedenvironmentfriendlybackfill compound and suitable clamp. 130 Supply and run of 25mm x 6mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection. 131 Supply and Run of 1 of No.8 SWG Copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection. 132 Supply and Run of 1 of No.8 SWG GI wire in suitable PVC rigid pipe on wall / floor / ground for earth connection. 133 Coil earth to street light poles with No.8SWG GI wire of 11.5metres of length in which 10metres of total length compressed into a coil of one meter length (75mm to100mm dia ) connected suitable with hexagonal earth bolt of size 8mm in to 25mm welded on the pole at one end with a coil position fixed on the earth. 134 Supply and fixing SFRC manhole chamber size 750 x750 mm square manhole cover onlyUsing M30 concrete rate includes of excise duty,Transporation charges, all other materials whichever necessary and labour charges etc as directed by the departmental officers. 135 Supply and Laying in position the best quality and 120mm diaHDPE pipes of ISI mark, providing leak proof joints etc and making connectin to all sanitary fittings, including dismantling masonry / RCC works whereever necessary and making good the dismantled portions to the original condition complying with standard specification. 136 Supply, Installation, Testing and commissioning of 32 channel 8 SATA NVR, with6THardDiskDrive4nos,NewlogicalandvisualizedGUIdesign Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected, ConfigurablenormalorhotspareworkingmodetoconstituteanN+1hot sparesystem VideoInputandTransmission,Connectableto thethird-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at upto12MPresolutionHDVideoOutput□HDMI1/VGA1outputs provided□HDMI1Videooutputatupto4K(3840×2160)resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface for HDD connection, Support upto 10TB capacity for each HDD, Smart search for efficient playback. and smart playback to improve the playback efficiency, Supports VCA search for fire/ship/temperature/temperature differencedetectiontriggeredvideofiles,POSinformationoverlayonlive view and playback, POS triggered recording and alarm Network & Ethernet Access□Hik-Connectforeasynetworkmanagement,2GigabitEthernet network interfaces. 137 Supply of 8MP, Internet Protocol fixed BULLET CAMERA with following specification:●1/2.5 Progressive Scan CMOS,●3840×2160@15fps,2.8/4mmfixedlens,01lux@(F1.2,AGCON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behaviour analyses ( Line crossing detection, intrusion detection)● Face Detection● 120dB WDR,● BLC/3D DNR/ROI, IP67 complied●On-boardStorage - Built-inmicro SD/SDHC/SDXCcardslot,upto128 GB,● Shutter Speed 1/3 s to 1/100,000 s,● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°,● rotate: 0° to 360°, 2.8 mm,● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°,●Lens Mount M12 ● IR Range I5: up to 50 m,●ImageSettingsRotatemode,saturation,brightness,contrast,sharpness adjustable by client software or web browser,●PowerConsumptionandCurrent-12VDC,0.7A,max.7.5WPoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W●Cameraoutfittedwithmetalhousingsoastopreventthelensfrom damages during physical abuse. 138 IP BASED VARIFOCAL LENS DOME CAMERA: Supply, Testing and Commissioning of 5MP Varifocal Motorized Dome IP Camera with following specification: Image Sensor: 1/2.7” Progressive Scan CMOSEffective Pixels:2592 × 1944Shutter Speed:1 s to 1/100,000 sS/N Ratio:≥52 dBAngle Adjustment:Pan : 0°~360°, Tilt : 0°~77°, Rotation : 0°~360°Video Compression: H.265 / H.264 / MJPEGH.264 Compression: Standard Base Line / Main Profile / High ProfileH.265 Compression: Standard Main Profile @ Leve4.1 High TierResolution : 5MP(2592×1944), 4MP(2560×1440), 3MP(2304×1296), 1080P(1920×1080), 720P (1280×720),D1, CIF, 480×24030m IR, Micro SD Slot, Ingress Protection: IP67Digital Zoom: YesImage Features: Defog, BLC, HLC, 2D/3D DNRCorridor Pattern: YesVideo Privacy :4 zones video maskPower Supply: DC12V / PoEPower Consumption: < 9.5W. 139 Supply, Installation, Testing and Commissioning of 42 smart LED TV with following specificationsa) Full HD 1920 x1080 (4K monitor)b) IPS panelc) Slim back light LED moduled) 900 PMIe) Triple XD enginef) Dynamic scanningg) ANRh) True colour generatori) 8modes of picturej) picture wizardIIIk) Real cinema 24Pl) HDMI -3nosm) USB -3nosn) Built in LANo) Magic remotep) Dimension 1242 x 724 x 55.1min(37).(Make: Sony/ LG /Samsung). 140 Supply and fixing of outdoor4X6PVC box with 102mm x 77mm x 102mm with all fixing accessories. 141 Supply and Laying of CAT 6 armoured cable in suitable PVCPipe 1 thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem)i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal)IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-T IEEE 802.5 16 MB; ISDN; TPDDI; ATMii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant.Fire Rating: PVC : IEC 60332-1.iii. Conductor - Bare Copper Wireiv. Insulation - Polyethylenev. Twisting - 2 Cores to the pairvi. Cable lay up - 4 Core to the pairIt has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm. 142 Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point ( Point to Point ) Crimping, Testing and arrangement charges. 143 Supply and laying of armoured, Singlemode, Thermoplastic Tape Inner Sheathed, PVC type sheathed 6 core Optical Fibre Cable withunique fiber excess length control method provides the cable with excellent mechanical and environmental properties and Cable - 2 Embedded FRP provides tensile strength & Anti-buckling properties. It is processed with Filling jelly - Thixotropic jelly to prevent Water ingress in loose tube. 144 Fixing and Termination of Optical Fibre Cable Single Point ( Point to Point ) Splicing and arrangement charges. 145 Supply and fixing of OFCPVC Black Colour Box 1x 3/4 x2 PVC Black colour Box. 146 Supply and fixing of 24 Port 2SFP with Module, PoE Giga Range Lan Switch.• 24Ports10/100/1000 Base-TPoE+ 4 x Combo Gigabit UTP or Gigabit SFP slots• Support IEEE 802.3af (PoE) and 802.3at (PoE+) Standard• Equipped with IEEE 802.3az Energy Efficient Ethernet (EEE) Complaint• SupportIEEE 802.1Q VLAN traffic segregation• Access Control List (ACL) feature to enhances network security• Auto Surveillance VLAN for easy integration with IP-based surveillance systems• Loopback detection (LBD) and broadcast storm control to avoid network downtime• Quality of Service (QOS) and bandwidth control to ensure smooth operation• Support Web-based GUI, Smart Console , Network Assistance Utility• Cable diagnostics function to help troubleshooting wiring problem including Optical Fiber Cable connecting network accessories. 147 Supply and fixing of POE 8 port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection /EFT protection for power line. ( Make : DLINK, NETGEAR / TPLINK ). 148 Supply and Fixing of Rack with Accessories -Higher end 4 U Rack and fan extra for the above rack. 149 Supply and Fixing of Rack with Accessories -Higher end 12 U Rack with LNS unit and fan extra for the above rack. 150 Supply and fixing of 2 feet CCTV Camera Stand with attachment fittings as follows:* Weather heads and couplings* Cabinet mounting fittings, plates, brackets as needed.* Reinforced couplings for wire entrances to cabinets. 151 Supply and Installation for 2KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2Hours back up 152 Supply and fixing of6mLengthpole with base plate of size 250x250x6mmasperIS-875withfollowingspecification.PoleOuterdie-76.10mmx 3.65mm Thick x 6 meter. Excavation, PCC, shuttering, reinforcement, Concretingfor fixing the post. The Rate is inclusive of curing with all necessary materials. (300x300x600). 153 PA System 154 Supply, Installation,Testing & commisioning of 30 watts 2 way high efficiency, high fidelity, long throw IP65 weather proof P.A Music Horn speaker. It combines the high efficiency of horn with wide frequency response.Music horn is weather protected and UV protected ABS plastic housing combines with the feature of easy poertap selection on a terminal strip with a two core cable.It has impedence of 250/500/1k/2k ohm with frequency response of 120-16000 hertz. (Make:AhujaAMH402T/Bosch or its equivalent). 155 Supply, Installation,Testing & commisioning of 480 watts P.A Mixer Amplifier with the output power of 1350 watts maximum, 500watt rms at 10% Thyristor harmonic distortion(THD), 850watt RMS at 5% THD, 800 wattsRMS at 2% THD and the power supply AC voltage ranging from 220-240 volt, 50/60 hertz. with the DC input of 48 volt and 1000watts has tone controls of Bass=+- 10 db at 100 hz weighing 42kg with the speaker output of2Q,4Q.70volt&100volt has power consumption of 1600VA AC &12A DC and 100db output regulation at 1khz no load to full load ratio. The signal to noise ratio is 60db with the imnput channels of 0.8mv/4.7kq,3*Aux 100mv/50kq.The frequency response of 50-15000hz+-3db.(Make:Ahuja SSA 10000/Bosch or its equivalent). 156 Supply, fixing & Testingof10 gooseneck with suitable base incorporates separate bush switches for momentary and dynamic microphone with 600ohm impedence and has 2.5mv/pa sensitivity and frequency response ranging from 50-15000hz with multi tone chime model.(Make:-ACM66 Ahuja/bosch/its equivalent). 157 Supply and run of 2core 1.5 Sqmm armoured speaker cablein suitable size of 38mm/50mm HDPEpipeinatrenchtobeexcavatedatadepthof0.75metreand refilling the earth to make good. 158 SAFETY SYSTEM 159 Supply of 2m x 1m Rubber Mat suitable for 11 KV installation confirming to IS. Set (5 Nos). 160 Supply of First Aid Box complete with all First Aid Medicines. 161 Supply of Shock Treatment Chart fixed in glass frame. 162 Supply of Fire Extinguisher Co2, 4.5 kg. confirming to TAC Norms.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 4
26.
Housing Urban and Rular Development #10204751 Price Bid
Tender For Lake Front Development At Porur Chennai.; 1 CIVIL WORKS 2 Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. 3 Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification. 4 Clearing Scrub Jungle, etc., complete complying with standard specification and as directed by the departmental officers. 5 Installation of Vertical Bored cast in situ RCC piles of 300 mm diameter and M-30 grade of concrete in all types of soils, using Standardised Concrete Mix of following grade, with sulphate resistant Cement or OPC/PPC, etc and Crushed Stone Sand and 20mm and down graded HBGS jelly coarse aggregate. The rate includes cost for placing of reinforcement cage in bore hole in correct position, cost of boring to the required depth with Bentonite solution with temprory casing of required length, conveyance of RMC to site and pouring concrete using Tremine pipes, conveyance of all materials to the site including all tools and plants, shifting the plants and equipments from one point to another, excavtion of mud pits for circulation of Bentonite soultion, closing the mud pits to original level and mud removal with initial lead and lift but including dismantling the concrete above the cut off level etc complete as directed by the departmental officers including socketing. The reinforcement cage should be welded properly for lifting. The concrete cubes to be tested as per IS 456-2000. Acceptance criteria by clause 16.1. Frequency of testing as per 15.2.2. Testing to be conducted at both the ends at site as well as RMC plant. Pile driving depth should be decided by the departmental officers at site. The length of pile for payment shall be measured from top of shoe to the bottom of the pile cap. (Cost of Reinforcement provided for Pile and Welding charges shall be measured and Paid separately) 6 Installation of Vertical Bored cast in situ RCC piles of 380 mm diameter and M-30 grade of concrete in all types of soils, using Standardised Concrete Mix of following grade, with sulphate resistant Cement or OPC/PPC, etc and Crushed Stone Sand and 20mm and down graded HBGS jelly coarse aggregate. The rate includes cost for placing of reinforcement cage in bore hole in correct position, cost of boring to the required depth with Bentonite solution with temprory casing of required length, conveyance of RMC to site and pouring concrete using Tremine pipes, conveyance of all materials to the site including all tools and plants, shifting the plants and equipments from one point to another, excavtion of mud pits for circulation of Bentonite soultion, closing the mud pits to original level and mud removal with initial lead and lift but including dismantling the concrete above the cut off level etc complete as directed by the departmental officers including socketing. The reinforcement cage should be welded properly for lifting. The concrete cubes to be tested as per IS 456-2000. Acceptance criteria by clause 16.1. Frequency of testing as per 15.2.2. Testing to be conducted at both the ends at site as well as RMC plant. Pile driving depth should be decided by the departmental officers at site. The length of pile for payment shall be measured from top of shoe to the bottom of the pile cap. (Cost of Reinforcement provided for Pile and Welding charges shall be measured and Paid separately) 7 Installation of Vertical Bored cast in situ RCC piles of 450 mm diameter and M-30 grade of concrete in all types of soils, using Standardised Concrete Mix of following grade, with sulphate resistant Cement or OPC/PPC, etc and Crushed Stone Sand and 20mm and down graded HBGS jelly coarse aggregate. The rate includes cost for placing of reinforcement cage in bore hole in correct position, cost of boring to the required depth with Bentonite solution with temprory casing of required length, conveyance of RMC to site and pouring concrete using Tremine pipes, conveyance of all materials to the site including all tools and plants, shifting the plants and equipments from one point to another, excavtion of mud pits for circulation of Bentonite soultion, closing the mud pits to original level and mud removal with initial lead and lift but including dismantling the concrete above the cut off level etc complete as directed by the departmental officers including socketing. The reinforcement cage should be welded properly for lifting. The concrete cubes to be tested as per IS 456-2000. Acceptance criteria by clause 16.1. Frequency of testing as per 15.2.2. Testing to be conducted at both the ends at site as well as RMC plant. Pile driving depth should be decided by the departmental officers at site. The length of pile for payment shall be measured from top of shoe to the bottom of the pile cap. (Cost of Reinforcement provided for Pile and Welding charges shall be measured and Paid separately) 8 Refilling with excavated earth in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification. 9 Supplying and filling with earth up to 10 Km for foundation and basement, etc., including watering and consolidating, etc., complete complying with standard specifications and as directed by the engineer-in-charge 10 Supplying and filling in foundation, basement, etc with Stone Dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 11 Supplying and filling in foundation, basement, etc with Crushed Stone sand filling in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 12 Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 13 Plain Cement Concrete 1:2:4 (one part of cement, two part of Crushed Stone Sand (M- Sand) and four part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 14 Construction of Granular sub-base of required compacted thickness by providing laying, spreading and compacting of Close graded Material conforming to Grading V of Table 400-1 of MORTH clause 401,mixing in a Wet Mix Plant of 200 tonne capacity at OMC, carriage of mixed material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory roller 8-10 tonne to achieve the desired density of 98% including protection of edges of GSB layer, cost of all materials, labour, hire charges of machinery, lighting, guarding, barricading, maintenance of diversion road, loading & unloading, all lead and lift etc., to achieve minimum CBR value of 30%(Compacted Thickness) in accordance with MORT&H technical specification clause No. 401 and with all other incidental charges and as per the direction of the Engineer-In-Charge of work. 15 Damp proof course with Cement Mortar 1:4 (One Cement and Four sand) 12mm thick mixed with best approved quality water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used and finishing, curing etc. complete complying with standard specification. 16 Providing Anti-termite treatment to soil adjecent and under building foundation, plinth periphery of the building by application of chemicals of IS 63613 part I to IV in stages to suit the progress of work consist as per the detailed specification as below.Including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing etc., complete and as directed by the departmental officers. 17 Random Rubble masonry in Cement Mortar (1:3) etc., Complete complying with standard specification and as directed by the Departmental Officers 18 Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid). 19 Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid). 20 For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc. 21 For plane surfaces such asrectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc. 22 For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc. 23 Centering for curved surfaces of all RCC items of work 24 Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part there of but not less than 30 cm, over the initial 3.00 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the department officers. 25 Providing and laying in position, Standardised Concrete Mix M-25 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kg/mᶾ and maximum water cement ratio of 0.50, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers.The coarse and fine aggregates to be used should comply with the requirements of IS Standards.(No separate payment will be made by the Department for the excess usage of materials). 26 Foundation and Basement 27 For Ground Floor 28 For First Floor 29 Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 400 kg/mᶾ and maximum water cement ratio of 0.45, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers.The coarse and fine aggregates to be used should comply with the requirements of IS Standards.(No separate payment will be made by the Department for the excess usage of materials). 30 Foundation and Basement 31 Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) 32 Brick work in Cement Mortar 1:3 using best quality of Second Class Ground Moulded Chamber Burnt Bricks 9 x 4-3/8 x 2-3/4 for foundation and basement including curing, etc., complete complying with standard specifiction. 33 For foundation & basement 34 In Ground floor 35 In First floor 36 Brick partition walls of 11.50cm thickness using best quality II Class Ground Chamber Burnt Bricks of size 9 x 4-3/8 x 2-3/4 in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately). 37 Ground floor 38 Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. 39 Inner Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. 40 Outer Plastering with Cement Mortar 1:4 (One cement and Four sand), 20mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. 41 Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers. 42 Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush.Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed.Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete. 43 White washing two coats with freshly burnt white shell lime in all floors including cost of lime, blue powder fevicol type gum, brushes, scaffolding charges, etc., complete complying with standard specification and as directed. 44 Supplying and painting the walls with two coats of wall putty as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications and as directed by the departmental officers. (The wall putty shall be got approved by the Executive Engineer before use of work). 45 Painting newly plastered wall surface with two coats of ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. Interior painting 46 Painting two coats of newly plastered wall surface with ready mixed Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. 47 Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) 48 Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) 49 Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers. 50 Flooring with first quality design ceramic tiles of all colours of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand)base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) 51 Paving the floor with best quality Double Charged Vetrified Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three M-sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification.(The make and brand of the tiles should be Johnson / Kajaria / Somany / Nitco / RAK which has to be got approved by Executive Engineer before use on works). 52 Providing And Fixing Machine Dressed Grey Granite Slab All Sides Machine Cut of Size 0.60 M X 0.60 M Size And 50 mm Thick Granite Slabs For Platform(Pavement) Including Cost And Conveyance ofGranite From Available Source Including Labour Charges For Fixing the Slab In Position To The LineLevel And GradientIncludingPointing With cm.1:3 And All Other Incidental Charges Etc.Complete 53 Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise andsimilar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification. 54 Paving the floor with Cement based Hydraulically pressed Anti skid tiles (pattern design) - 20 mm thick (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works). 55 Dadooing walls with Colour designed digital print ceramic tiles, with borders, with size of 300mm x 450mm x 8mm and above set in Cement Mortar 1:2 (One Cement and Two M-sand)10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. nbatly in all floors, curing, etc,,complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be like Johnson / Kajaria / Somany / Nitco / RAK or Equivalent which has to be got approved by Executive Engineer before use on works). 56 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between.The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete.The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete 57 Nosing the granite slab - single nosing as directed by the engineer-in-charge 58 Grooving the granite slab as directed by the engineer-in-charge 59 Manufacturing, supply & fixing of precast kerb stone of size 400mmx259mmx200mm thick made of M 20 grade of concrete rectangular in shape with one corner chamfered by 100 mm x 100 mm as per approved design i/c cost of all material, labour and curing etc., complete. as per IRC 5758 - 1984. 60 Supplying and laying hydraulic pressed monolithic natural grey colour cement concrete inter locking paver block of 63mm thick, in cement concrete 1:2:4 (one cement, two sand, four aggregate) using difference design and with stand for pressure of 150 - 200 kg/m2 over the existing sand cushion by using earth rambers and also vibratting the concrete blocks often laying using plate vibrators etc, complete as directed by the departmental officers. 61 Supplying and fixing of M.S.grill of approved design for grill gate, grill work to doors and windows openings ramp etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including priming coat of best approved quality red oxide primer etc., complete complying with standard specification. 62 UPVC Window Specification:Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle.The corners and joints should be welded and cleaned.Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong lockingsystems and as per size for arresting noise and energy loss.The connecting mechanism between sash and outer frame that enables opening of the window.The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames.The window should be got approved from the Executive Engineer before use on work 63 Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm.The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber.The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug. 64 ABS DOOR Specification:Providing and fixing of ABS (Acrolynitrile Butadiene Styrene) Door using factory made plain FPVC (Foamed Polyvinyl Chloride) door frame of the size 105 x 40mm with a wall thickness of 10mm made out of extruded rigid FPVC profile mitre joined with 10 Nos. of 50mm long screw.The door frame shall be fixed to the wall by using 80mm long screws through the frame with the help of PVC fasteners to be provided for each vertical member, stiffeners of (‘U’ Channel of size 29 x 9 x 1mm, 150mm long) 3 Nos. at hinge point, frame reinforcement of (‘U’ GI Channel of size 46 x 22 x 0.06mm), bottom tie rod of (‘U’ GI Channel size of 15 x 15 x 1mm), the ABS Shutter of 35mm thick factory made plain pre-laminated.ABS (Acrolynitrile Butadiene Styrene) door shutter moulded in different designs, consisting of all round Frame made out of water proof solid foam PVC bar of size 20x32mm, reinforced by 32 x 32mm - 2 Nos. for vertical made out of LVL (Laminated Veneer Lumber), core material of 32mm thick high density craft paper honey comb board, sandwiched on both sides with pre-laminated ABS sheet thickness of 1.5mm.PVC edge banding of size 0.45mm on the vertical sides.Hardware made out of ball bearingbutterfly hinges - 3 Nos. for each shutter and ISI make SS round lock complete, including cost of Materials, conveyance and all other incidental charges and labour charges for fixing the Door neatly etc., complete complying with the standard specification. The door shutter and frame should be got approved from the Executive Engineer before use on workPlain Pre-laminated Door 65 Fabrication supply and fixing in position of aluminium natural colour matt finish louvered ventilator in all floors made with extruded aluminium section of following size with necessary accessories such as rubber beading, best quality of handle including supplying and fixing of 4 mm thick plain glass including cost of all materials, labour power consumption required for fabrication drilling holes in RCC column/floor slab/ masonry wall wherever necessary with power drills to the required extent and making good to the original condition after fixing etc., and as directed by the departmental officers etc. complete.The aluminium frames to be anodised under electrically controlled condition in accordance with ISI 1868/ 1962 specification for an average anodic film thickness of not less 15 microns and all the materials should be got approved by the Executive Engineer before use on work. Outer frame alround section of size 62x38x2mm @ 1.174 kg/ m vertical louvered section of size 60x30x4mm @ 1.27 kg/m and aluminium clips of size 19.05x10.27/11.05x1.20mm @ 0.169 kg/m. 66 Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification 67 Roofing with best quality prelaminated Polycarbonate Sheet 6mm thick of approved colour design and quality including cost of self tapping screws between washer and cutting the sheet to required slope if found necessary during execution of work, including charges for machine etc., complete, as directed by the engineer-in-charge 68 Supplying and fixing of Exterior WPC louvered panel for cladding and roofing works with material specifications: Material - WPC, Size - 2900 x 200 mm, Design exterior decorative panel, Color - Brown, Usage/Application for all kinds of exterior work, Thickness - 26mm, Core Filling - Fly Ash, Packaging Type - fully packed, etc., complete as directed by the engineer-in-charge 69 Supplying and Fixing ofCNC cut perforated Enclosure for EB transformer and EB pillar Boxes by using CNCMS Sheet (2mm thick), doorhinged with vertical support of80X40 mm TubularPost including horizontal Support and Stiffener (40 x40 x2mm)for MS sheet including Powder coating ofall structural members and labor for fitting , welding andtransportation of thematerial from thefactory to Site as directed by the engineer - in charge. 70 Providing and fixing of Aluminium Composite Panel (ACP) 4 sided having 50 x 25 x 1.50mm frame work vertical and horizontals out of specially designed extruded sections withstand wind pressure of 180 Kg/sq.m and fabricated fixed at all level elevation and heights.The extruded section cutting and fixing required space extruded section shall be of 6063 and alloy of BSH 9 confirming T is – 63400 rate shall included to fix the main frame with necessary clamps, fasteners, bolt nuts etc.The main frame of extruded section shall be of 22843 & 22739 (H9) grade conforming to BS 4174 (or) IS 8147.Rate shall included 4mm thick ACP sheet (0.25 + 3.5 + 0.25) alstrong or equivalent fixing with spacer tape and the ACP sheet bounded with special type structural sealant of dow corning 789 or equivalent in dust free conditions the gaps between ACP sheet to be filed with whether sealant and backer rod or 12mm foam sheet to ensure water and air tightness in all complete complying with standard specification as directed by the departmental officer 71 Refixing of damaged cement concrete solid block masonry in CC 1:3:6 (One of cement, three of sand and six of course aggregate) using 6mm and below HBG stone jelly with compressive strength of 50 kg/cm2 in cement mortar 1:5 (one of cement and five of sand ) including curing and neat finish etc., complete complying with standard specification and as directed by the departmental officers at site of work 72 Supplying and fixing of cement concrete solid block masonry by using solid blocks of size 400x200x150mm confirming to IS 2145-1965 made in CC 1:3:6 (One of cement, three of sand and six of course aggregate) using 6mm and below HBG stone jelly with compressive strength of 50 kg/cm2 in cement mortar 1:5 (one of cement and five of sand ) including curing and neat finish etc., complete complying with standard specification and as directed by the departmental officers at site of work. 73 Supplying and providing chain link fence with RCC posts.The RCC postswill be of 2.5m c/c and of 2.75mheight.The post will be 100mm square at top and 150mm square at bottom 2.15m height above ground level and 0.60m below ground level, in R.C.C 1:1.5:3mix using 12 to 20mm gauge stone jelly with necessary reinforcement moulding work and rendering smooth with cement at 15kg/cu.m etc., complete and fixed in c.c. foundation in 1:4:8 using 40mm size stone jelly. The foundation is of size 45x45x90 with sand filling 15cm height. The fencing will be of chain link 75mm size, 10 gauge. The height of fence is 2.0m after leaving 75mm gap from ground level including fixing the fence with the posts using G.I binding wire, etc. complet.ISI STD 74 Supplying and fixing Country wood scantlings for door, windows, joints, rafters, etc., or any other works using country wood scantlings in following lengh and complete it in all floors including labour charges for the manufacture of frames as per standard specification. 75 Country wood scantlings below 4m in length 76 Providing two legged Scaffolding using 15cm dia casurina post of 4m over all length (3m height + 0.5m Projection + 0.5m into the ground) the distance between the two rows being 1.25 and the spacing of posts being 2.0m in both the rows with two horizontal posts with 0.5m. Overlap on either side and braces at 2.0m centre to centre including longitudinal and transvers middle braces to step up and providing a platform with country wood planks of 40mm thick and 1m width, etc. in acomplete from using coil and nails - 1RM 77 For Initial height of 3.00 metre 78 For every additional height of 2.5 m above initial height of 3 m 79 Supply and fixing of 3-seater metal garden swing chair with canopy of material and specifications: Seating capacity - 3 seater swing, Material- metal, Appearance - modern with canopy, Cushion - Included, Usage/Application - balcony, garden, lounge, etc., Cushion material - polyster, etc., complete, as directed by the engineer-in-charge 80 Supplying,erectingandFixingprecast reinforcementbench with back rest. Bench shall consist of 2 nos. L shaped bases support in natural cement color of thickness 100mm, back height 1000mm, front height 450mm, base width 620mm and 5Nos Reinforced Concrete planks in red colorandsizeof 1500x100x50mm and 1no. reinforcedconcrete plank of 150x200x50mm: manufactured by using M-30 grade concrete & reinforced suitably: all parts to be joined with galvanized nuts and bolts of suitable size. 81 Supply & placing of FRP heavy duty three compartment Dustbin of size 1200 x 450 x 900 mm with top cover 82 Supply & placing of light weight concrete Dustbin of size 450 dia x 900 mm with top cover 83 Supply and placing of Monkey DustbinFRP – 2 Layers to a height of 3½ and width of 2½ 84 WATER SUPPLY AND SANITARY WORKS 85 Supplying and fixing in position best approved of BIS quality 110 mm dia PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of U clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification. 86 Supply and providingPriming Tank made up of PVC, Make: SINTEX / EQUIVALENT 87 Internal water supply - Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works. 88 For laying PVC pipes of dia 32mm 89 External Water Supply - Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works. 90 Above Ground Level 91 For laying PVC pipes of dia 40mm 92 Below ground level 93 For laying PVC pipes of dia 50mm 94 For laying PVC pipes of dia 40mm 95 For laying PVC pipes of dia 25mm 96 Supplying, laying and jointing CPVC pipes of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using CPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto etc., complete complying with standard specifications.The CPVC pipes shall be got approved by Executive Engineer before use on works.(Above Ground Level) (Internal Water supply) 97 Above Ground Level 98 For laying CPVC pipes of dia 32 mm 99 For laying CPVC pipes of dia 25 mm 100 Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements).The valves to be used on work shall be got approved by the Executive Engineer before use on work. 101 Gate valve 102 Fixing Gun Metal Gate Valve of 25 mm 103 Fixing Gun Metal Gate Valve of 40 mm 104 Wheel valve 105 Fixing Gun Metal Wheel Valve of dia 25 mm 106 Fixing Gun Metal Wheel Valve of dia 40 mm 107 Providing, fixing, Testing & Commissioning of PVC Ball valve with quarter turn including all necessary fittings & accessories complete. PIMTAS / AQVASTAR make 50 mm ( 2 ) 108 Providing, fixing, Testing & Commissioning of PVC Ball valve with quarter turn including all necessary fittings & accessories complete. PIMTAS / AQVASTAR make 40 mm ( 1.5 ) 109 Providing, fixing, Testing & Commissioning of PVC Ball valve with quarter turn including all necessary fittings & accessories complete. PIMTAS / AQVASTAR make 25 mm (1.00”) 110 Supplying and fixing in position 15mm dia brass CP Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works). 111 Supplying and fixing in position Health faucet of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works). 112 Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia B class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). 113 White Glazed Wash Hand Basin 114 With Pedestal 115 Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks). 116 Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works). 117 Supplying and fixing best approved best quality brass CP soap tray of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications.(The soap tray should be got approved by Executive Engineer before use on works). 118 Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level. 119 For laying PVC pipes of dia 110 mm 120 Supplying and fixing in position PVC cowls of 110 mm dia of best approved quality conforming to BIS, etc., complete complying with standard specifications.(The PVC cowl should be got approved by the Executive Engineer before use on works). 121 Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with P or S trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers.(The water closet should be got approved by the Executive Engineer before use on works). 122 Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm P or S trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications.(The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works). 123 White glazed European Water Closet with 10 litre capacity PVC flushing tank fixed on to wall 124 Supply and fixing in position of best Indian make white glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers.(The urinal should be got approved by the Executive Engineer before use on works.) 125 Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works).Nahani Trap of size 100 x 75mm with stainless steel gratings 126 Supplying and fixing in position 150 x 100mm P or S stoneware gully trap A grade with CI double gratings of size 150 x 150mm and 230 x 230mm at bottom and top respectively with necessary earth work excavation laid over a bed of brick jelly cement concrete 1:3:6 (One cement, Three sand and Six broken brick jelly) 150mm thick using 40mm size broken brick jelly including necessary brick work and plastering including dismantling masonry wherever necessary and re-doing the damaged portions to the original conditions using cement concrete 1:3:6 using 20mm stone jelly for fixing the gully trap and giving connections to stoneware sewer line etc., complete complying with standard specifications. [Earth work excavation, brick work, plastering shall be measured and paid separately]. The stoneware gully trap should be got approved by the Executive Engineer before use on works. 127 Supplying and fixing single phase 1 HP Monoblock pumpset as per I.S.I. specification on suitable pedestal with foundation bolt and nut including labour. Supply and fixing of starter and main switch suitable for 1 HP pumpset on suitable angle iron frame work with necessary labour including panel board.Supply and fixing 1 No. foot valve 1 for the 1 HP Mono block pumpset supply and run of 4 of 10 sq.mm. in PVC pipe with 14 SWG TC wire etc., complete. 128 Construction of Inspection chamber of size (clear 0.60x0.60x1.00) with necessary earth work excavation, sand filling, CC 1:5:10, brick work in CM 1:5, plastering in CM 1:5 12mm thick, Plastering in CM: 1:3 20mm thick, Precast slab 50mm thick, fabrication etc. complete as directed by the engineer-in-charge 129 Providing rain water recharging collection pit having a size of 900mm dia to a total height of 1200mm is 150mm above ground level and 1050mm below ground level with necessary augar bore of300mm dia to a depth of 3000mm from bottom level of collection pit and filled with 20mm HBG stone jelly inside of augar bore. The sides of collection pit provided with RCC Well ring of inner size of 900mm x 300mm x 50mm with 6mm reinforcement on both directionat 200 mm c/c using RCC 1:1/2:3 (one cement, one and half sand and three HBG jelly). The top of collection pit is finished with 50mm thick cover slab, The collection pit is filled with course river sand at top, 20mm HBG stone jelly at middle and 40mm HBG stone jelly at bottom of a depth of 300mm, 450mm and 450mm respectively. The rate is including the cost of RCC well ring and filling materials, RCC cover slab, drilling hole and labour charges for erecting the well ring etc.,and as directed by the departmental officers. 130 Supply, Fixing & commissioning of Pop up spray RD 1804 SAM PRS Series Spray bodies with high efficiency HE VAN Nozzle capable of covering radius of 0.9-4.6m at 1.0 - 2.1 Bars, pressure with Matched precipitation rate, tactile click and DU >0.7. Triple Blade Wiper Seal precisely balances flushing, flow- by and debris protection to optimize performance and durability at pop up and retraction. Precision-controlled flushing at pop-up and retraction clears debris, ensuring positive stem retraction in all soil types. Unique debris pockets hold grit in place, removing it from circulation and preventing long-term damage. Parts resistant to corrosion in treated recycled water containing chlorine. Pop spray body shall with stand upto 6.9 bar. Built-in Seal-A-Matic™ (SAM) check valve. Traps water in lateral pipes in elevation changes of up to 14 feet (4.2 m). PRS Maintains constant outlet pressure at 30 psi or 45 psi at varying inlet pressures. etc., RD1804- SAM PRS-HE VAN incl installation charges 131 Supply of large capacity Disc filter 25 M³ / Hr including installation charges. (brands like Rain Bird or equivalent) 132 Flexible polyethelene irrigation pipe 16 mm dia / 2.5 / 1.1 - 1.4 mm CL - II. Netafim including installation charges. 133 Supply of endcap, nipple, start nipple, rubber grommet 16 mm dia. Netafim including installation charges. 134 Supply of Pressure compensated dripper with 2 / 4 / 8 LPH outlet flow. Rain Bird / Netafim make including installation charges 135 Supply of Micro sprinkler of half & full circle with 55 LPH output flow with necessary micro tube & stake. Rain Bird / JISL make including installation charges. 136 BOREWELL 137 Drilling of 12 dia vertical borewell so as to have a finished size of 6 dia borewell in boulder area to any required depth as decided by the TWAD Board Officers including Transportation from one place to anothr place with in Tamilnadu State by direct or reverse rotary mud circulation method using Contractors rig tools, fuel, labourers etc 138 Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 140 mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs, fuel, labour and drilling bentonite and water required for drilling at site ( Site will be shown by the TWAD Board Officers) including construction of mud pit 139 Drilling of 140/150 mm pilot bore - Upto 60 m Depth ending below ground level 140 Drilling of 140/150 mm pilot bore - From 60 m upto 90 m Depth ending from ground level 141 Drilling of 140/150 mm pilot bore - From 90 m upto 120 m Depth ending from ground level 142 Reaming 300 mm dia pilot bore to 400mm/ 450mm dia bore as directed by the TWAD Board Officer. 143 Upto 60 m depth ending below ground level 144 Reaming 140/150 mm dia pilot bore to 300mm dia bore as directed by the TWAD Board Officer. 145 Upto 60 m depth ending below ground level 146 From 60 m depth and upto 90 mt depth ending below ground level 147 From 90 m upto 120 mt depth ending below ground level 148 Supply and laying following dia PVC casing pipe with excise duty as per IS 12818 / 2010 149 200mm dia CS 150 150mm dia RS 151 Labour charges for inserting PVC casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC couplers with cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the Executive Engineer of Departmental officers. 152 200mm dia CS 153 150mm dia RS 154 Supplying and filling with river pebbles in annular space between bore and PVC pipe up to hard rock 155 Charges for developing the borewell with air compressor of 300 CFM capacity (Minimum 8 Hours) including ransportation labour and fuel charges for compressor as directed by TWAD Board Officers and conducting yieldtest by V notch method. 156 Supply ,erection and testing & commisioning of 3HP submersible pumpset in the to suit 200mm borewell of capacity of 4800 LPH @ 265Ft, max. total head of 280 Ft pumps fitted with bronze impellers and having delivery size of 40mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge and other required supporting items like SS hose nipple, nylon rope, clamps, bolt and nuts,GI nipple, 50mm dia HDPE hose of required length etc completed and as directed by the officer incharge. 157 Supplying and fixing single phase 5 HP Monoblock pumpset as per I.S.I. specification on suitable pedestal with foundation bolt and nut including labour. Supply and fixing of starter and main switch suitable for 5 HP pumpset on suitable angle iron frame work with necessary labour including panel board.Supply and fixing 1 No. foot valve 2 for the 5 HP Mono block pumpset supply and run of 4 of 10 sq.mm. in PVC pipe with 14 SWG TC wire etc., complete. 158 LANDSCAPING WORK 159 Supply & stacking of red earth at site to the departmental guage for pre-measurements which is of light textured, crystalline, porous and friable and not of generally acidic or neutral but not of alkaline and should be fertile, including seignior age charges, cost of transportation, loading, unloading, stacking and inclusive of all taxes etc., complete. 160 Supply of well decomposed Farm yard Manure in a powdery form, devoid of soil sand, stones, plastics and other materials, highly nutrient and which supports plant growth. 161 Supply and stacking of pit sand / earth filling sand at site to the departmental gauge for pre measurements obtained from sand deposits and should clean without solid particles 162 Mixing charges of Red soil, sand and manure uniformly (1:1:1) for Preparation of soil mixture (excluding material cost) 163 Spreading of red soil, gravel or sand including watering and rolling which hand roller for every 75 mm thickness - including hire charges of roller 164 Preparation of Mounds of various size and shape by availlable excavated/ Supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer - in - charge 165 Planting of Lilly - Hymenocallis Lilly (Spider liiy) shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge 166 Planting of Plumaria Dwarf ornamental foliage Specimen plant variety of height 105- 120 cm in polythene bag of size 16x16 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 167 Planting of Duranta new gold Plant ornamental foliage shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 168 Supplying and Planting of Peltophorum tree sapling of height 240 – 300 cm in polythene bag of size 20x21 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 169 Planting of Bougainvillea Specimen plant variety of height 105-120 cm in polythene bag of size 16x16 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 170 Supplying and Planting of Picharidia palms variety of height 180-210 cm in polythene bag of size 16x16 inch including supporting stack of 5cm dia casurina pole of 10 height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 171 Supplying and Planting of Roystonea regia (Royal palms) palm variety of height 180-210 cm in polythene bag of size 16x16 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 172 Supplying and Planting of Pungam tree sapling of height 240 –300 cm in polythene bag of size 20x21 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge 173 Supplying and Planting of Bauhinia purpurea tree sapling of height 240 – 300 cm in polythene bag of size 20x21 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed bythe site in-charge. 174 Supplying and Planting of Spathodea campanulata tree sapling of height 240 – 300 cm in polythene bag of size 20x21 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in charge. 175 Supplying and Planting of Cane Bamboo tree sapling of height 300 - 360 cm in polythene bag of size 15x16 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge 176 Planting of G2 grass including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 177 CHILDREN PARK AND GYM EQUIPMENTS 178 Supply and fixing of Straight Slide - 7ftLength 450cm ( 15ft ) x Width 75cm ( 2.5ft ) x Height 210cm ( 7ft ) Slide Material : Polyethylene Slide. Slide Length : 21cm ( 7ft ), Slide platform height : 120cm ( 4ft ), Base platform size : 2ft x 2ft, Platform base : Aluminium Checkered Sheet. Center Post : 114mm OD Galvanized post, Side Post : 50mm (2) OD Galvanized post, Powder coating : Electrostatic pp coating on metal parts. Area Required : Length 600cm ( 20ft ) x Width 150cm ( 5ft ) Playing age group : 3 - 10 yrs. Children capacity : 1Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. All fastners closed with polyethylene caps for children protection. 179 Supply and fixing of Park Spiral Slide Junior (FRP)Size: L10.5 x W6 x H7Safe Area Size: L20.5 x W5 x H11.5Material specifications:Ladder : Galvanished ‘B’ Class pipe Sliding chute 9ft BED LEG :Galvanished ‘C’ Class pipeFRP thickness 4mm. (Reinforced Polymers in 5 Layers) 450 CSM Matt, 600 Roving Mat, Isotolic gel coat with PU pigment.ISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball BearingHigh quality Glossy paint with primer 180 Supply and fixing of Cross Swing - 3 Seater Length 390cm ( 13ft ) x Width 120cm ( 4ft ) x Height 225cm ( 7.5ft ) Swing Seat material : LLDPE seats fitted with Stainless steel hooks. Swing Chain : PU coated coated galvanized chain Imported. Swinging Hook : Heavy duty Aluminium pressed with sealed bearing. Swing post : 114mm ( 4.5 ) OD G.I post of wall thickness 2mm, Centre post : 114mm ( 4.5 )OD G.I post of wall thickness 2mm, Playing age group : 3 - 12yrs. Children capacity : 3Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. Swing chain made of PU coated chain , Seat made of LLDPE ( Polyethylene), Swing hooks made of Aluminium with sealed bearings.4. All fastners closed with polyethylene caps for children protection. 181 Supply and fixing of Seesaw - SingleLength 210cm ( 7ft ) x Width 90cm ( 3ft ) x Height 60cm ( 2ft )Seesaw seat material : LLDPE - Polyethylene. Qty : 2Nos.Seesaw center & side post : 89mm ( 3.5 ) OD Galvanized post,Seesaw handle post : 32mm ( 1.2 ) OD Galvanized post,Seesaw post top cap : Heavy duty Aluminium,Powder coating : Electrostatic pp coating on metal parts.Area Required : Length 300cm ( 10ft ) x Width 210cm ( 7ft )Playing age group : 3 - 10yrs.Children capacity : 2Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. All fastners closed with polyethylene caps for children protection. 182 Supply and fixing of Park Seesaw 4 Seater (FRP Seat)Size: L8.75 x W5 x H3 Safe Area Size: L11.75 x W8 x H6 Material specifications:Frame : 1 ½” Galvanished ‘B’ Class pipeSee saw Rail :2” Galvanished ‘C’ Class pipeSeat : FRP Seat with 450 CSM Mat 3 Layers bonding. Isotolic gel coat with UV pigment.Painting with PU coating seatISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball Bearing 183 Supply and fixing of Merry go round - 6 Seater Diameter 180cm ( 6ft ) x Height 75cm ( 2.5ft )Galvanized 50mm dia pipe used for outer ring.Heavy duty Tapper roller bearing setting on the base for smooth rotation.Powder coating : Electrostatic pp coating on metal parts.Area Required : Length 240cm ( 8ft ) x Width 240cm ( 8ft )Galvanized semi circle seats - 2Nos with side saftey handles.Playing age group : 3 - 12yrs.Children capacity : 6Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. All fastners closed with polyethylene caps for children protection. 184 Supply and fixing of Spring Rider - Dinasour Polyethylene Dinasour design attached with 22mm heavy duty coil springs mounted on 10mm Base plate. Metal part powder coated. Safe area - 6ft x 6ft. Playing age group : 3 - 10yrs. Children capacity : 2 Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. All fastners closed with polyethylene caps for children protection. 185 Supply and fixing of Park Loop RungSize: L10 x W2 x H7.5Safe Area Size: L13 x W5 x H10Material specifications:Post-Galvanished ‘B’ Class pipeTop rail-Galvanished ‘C’ Class pipeSprings –Galvanished ‘C’ Class pipe.Painting with PU coating ISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball BearingHigh quality FRP Materials with U~V resistance pigments and ISO Resign and 600 GSM Mat 186 Supply and fixing of Park Flat RotorSize: L5 x W5 x H3.25’ Safe Area Size: L8 x W8 x H6.25Material specifications:Pipes - 1’’GI pipe, 3/4”GI pipe, 3”GI pipe, 2.5mm thick, B class paint: PU coatingISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball BearingHigh quality FRP Materials with U~V resistance pigments and ISO Resign and 600 GSM Mat 187 Supply and fixing of Park Arch Swing 2 Seater (FRP)Size: L10 x W3 x H6.75Safe Area Size: L13 x W6 x H10Material specifications:ARC-Frame : 2.5mm thickness Galvanished ‘B’ Class pipe Top Rail : 2” Galvanished ‘C’ Class pipe with 4.5mm thickSeats : RubberChain : 8mm Stainless Steel Chain (Grade-304)Painting with PU coating ISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball BearingHigh quality FRP Materials with U~V resistance pigments and ISO Resign and 600 GSM Mat 188 Supply and fixing of Air Walker Single personSize: L3.75 x W1.25 x H5 Safe Area Size: L6.75 x W4.25 x H8Material specifications:Main Post made of 4 Inch Pipe and other main pipes 1-1/2 inch Pipes. 3 mm thickness pipes (1680 x 515 x 1780 mm) 4 mm pipe Double coat Powder coating, Heavy duty Branded sealed Ball bearing, for long lasting life. Steel Foot rest / Foot Paddle for long lasting life. 189 Supply and fixing of Chest Press - Single PersonSize: L7.5 x W2.5 x H6Safe Area Size: L10.5 x W5.5 x H9Material specifications:Main Post made of 4 Inch Pipe and other main pipes 1-1/2 inch Pipes. 3 mm thickness pipes. Double coated Powder coating, Heavy duty Branded sealed Ball bearing, Steel & foot rest / Foot Paddle for long lasting life 190 Supply and fixing of Leg Press - Dual PersonDimension : L 120cm ( 4ft ) x W 45cm ( 1.5ft ) x H 130cm ( 4.3ft ) Material : Galvanized Steel. Fastners : Stainless steel 304 grade with Polycaped. Post top Cap : High density Aluminium. Handle grips : HD Rubber coated. Twister Base : Polyethylene. Bearing setting for smooth rotation. Main Post Size : 115mm / 4.5 OD G.I post of wall thickness 3mm. Handle Post Size : 32mm / 1.25 OD G.I post of wall thickness 3mm. Powder coating : 80 micron Akzo nobel electrostatic coated. Area Required : Length 180cm ( 6ft ) x Width 180cm ( 6ft )All Metal posts are made of Galvanized pipes with elecrostatic powder coated. 191 Supply and fixing of Push Up / Pull BarSize: L3.5 x W3.5 x H6.5Safe Area Size: L6.5 x W6.5 x H9.5Material specifications:Main Post made of 4 Inch Pipe and other main pipes 1-1/2 inch Pipes. 3 mm thickness pipes Double coat Powder coating, Heavy duty Branded sealed Ball bearing, for long lasting life. Steel Foot rest / Foot Paddle for long lasting life. 192 Supply and fixing of Shoulder Wheel - Single PersonSize: L2 x W2.5 x H6.25Safe Area Size: 4 x 5.5 x 9.25Material specifications:4mm pipe thick Main Post made of 4 Inch Pipe and other main pipes 1-1/2 inch Pipes. 3 mm thickness pipes Double coat Powder coating, Heavy duty Branded sealed Ball bearing, for long lasting life. 193 Supply and fixing of Excer CycleProduct Dimension : L 85cm ( 2.8ft ) x W 83cm ( 2.7ft ) x H 182cm ( 6.1ft ) Material : Galvanized Steel. Fastners : Stainless steel 304 grade with Polycaped. Post top Cap : High density Aluminium. Rotating Knobs : Polyethylene. Bearing setting for smooth rotation. Main Post Size : 115mm / 4.5 OD G.I post of wall thickness 3mm. Handle Post Size : 32mm / 1.25 OD G.I post of wall thickness 3mm. Powder coating : 80 micron Akzo nobel electrostatic coated. Area Required : Length 180cm ( 6ft ) x Width 180cm ( 6ft )All Metal posts are made of Galvanized pipes with elecrostatic powder coated. 194 Supply and fixing of Lat Pull Down - Single personDimension : L 100cm ( 3.3ft ) x W 75cm ( 2.5ft ) x H 180cm ( 6ft ) Material : Galvanized Steel. Fastners : Stainless steel 304 grade with Polycaped. Post top Cap : High density Aluminium. Handle grips : HD Rubber coated. Seat & Back rest : Polyethylene. Bearing setting for smooth rotation. Main Post Size : 115mm / 4.5 OD G.I post of wall thickness 3mm. Handle Post Size : 50mm / 2 OD G.I post of wall thickness 3mm. Powder coating : 80 micron Akzo nobel electrostatic coated. Area Required : Length 180cm ( 6ft ) x Width 180cm ( 6ft )All Metal posts are made of Galvanized pipes with elecrostatic powder coated. 195 Supply and fixing of Sit Up BoardDimension : L 142cm ( 4.7ft ) x W 112cm ( 3.7ft ) x H 63cm ( 2.1ft ) Material : Galvanized Steel. Fastners : Stainless steel 304 grade with Polycaped. Post top Cap : High density Aluminium. Base material : 25mm OD Galvanized Oval pipes. Post Size : 115mm / 4.5 OD G.I post of wall thickness 3mm. Post Size : 45mm / 1.5 OD G.I post of wall thickness 3mm. Powder coating : 80 micron Akzo nobel electrostatic coated. Area Required : Length 240cm ( 8ft ) x Width 240cm ( 8ft )All Metal posts are made of Galvanized pipes with elecrostatic powder coated. 196 KIOSK 197 ACP KioskSupply of Kiosk: MS Tube Frame Covered with ACP Panel Size: 3m x 2m Bottom: Bison Board 1” Thick Front: Large Door with Double Piston Left Side: Access Window Right Side: Main Door With Lock Top: ACP Sheet (Puff Panel) Table: 7.5Ft x 1.5’ Width 1no Accessories: Fan 1No, Tube light 2Nos, Switch Box 1No, MCP 1No, Exhaust Fan 1No, Wash Basin 1No, Vinyl Flooring, LED Name Board with Logo, Menu Card 198 ELECTRICAL WORKS 199 LT CT TNEB METER BOX: Supply, Installation, testing and commissioning of compartmentalised LT 3Phase, TNEB Metering box of outdoor weather proof type with MS mounting stand, Test Terminal Blocks, Internal control wiring etc., as per local TNEB standards. The box suitable for 3phase 100A service connection made up of with hylem sheet of size 2feet x 1-1/2feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of3Nos.100A fuse units (500V),1No.neutral link,copper earth flat of size1x1/4 with interconnection of EB meter tofuse units by 16 Sq.mm PVC insulated copper wire with suitable necessary connection with earth connection complete. 200 Supply and fixing of 125A TPN Isolator in sheet steel enclosure with double breakon suitable angle iron frame work with MS cable entry boxes with earth connection only. 201 MAIN LT PANEL: Supply, Installation, testing and commissioning of 3Phase, 415Volts, Main LT Panel board of Indoor, Cubicle floor mounting type made out of 2mm thick CRCA Sheet with powder coated finishing, MS base frame, double internal earthing arrangements, 125Amps, rating TPN Copper busbars with interconnection busbar, etc., comprising of the followings:EB Incomer :1 No. 125Amps, 25kA, 4Pole, Thermal magnetic MCCB with Ext.RHOMMetering : 1 Set of RYB LED Indication lamps1 No. of Multifunction Meter with RS 4851 Set of Current Tranformers (125/5A, Cl-1), 1 No. 125/5A CT for APFCR1 Set of Control MCBs Outgoings: 7 Nos. 63Amps, TP+N MCCB 2 Nos. 32Amps, TP+N MCCB3 Nos. 25Amps, DP MCB[Size:2400mm (L) x 350mm (D) x 2000mm(H)] 202 APFCR PANEL - 25KVAR: Supply, Installation, testing and commissioning of 3Phase, 415Volts, 25KVAR rating APFCR (Capacitor) Panel board of Indoor, Cubicle floor / wall mounting type made out of 2mm thick CRCA Sheet with powder coated finishing, MS base /wall frame, double internal earthing arrangements, 63Amps, rating TPN Copper busbars with interconnection busbar, etc., (1 x 10KVAR + 2 x 5KVAR + 1 x 3KVAR + 1 x 2KVAR) 203 12WAY Outdoor Lighting DB - 1 to 5: Supply, Installation, testing and commissioning of Outdoor weather proof type 3Phase Outdoor Lighting DB comprising of 1 No. 63Amps, TP+N, MCCB with Extended RHOM as incomer with RYB LED Phase indication lamps, 3Phase 63Amps, 4Pole Timer internal control wiring, etc., Outgoings: 11 Nos. 16A-32Amps, 4P MCBs &3 Nos. 20Amps, DP MCBs including Copper busbar connections, interconnection cables, cable entry provisions, floor mounting frame (600mm to 900mm), etc., 204 SLDB-1 to 4 and ELV UPS DB: Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1no. 32A DP MCBswitch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wallwith earth connection only.Higher End 205 Pump room DB - 1 & 2: Supply and fixing of 8 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB switch as incoming and 5 nos. 32A 3P MCB, 9 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End 206 SupplyandLayingof31/2 Corex120 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 207 SupplyandLayingof31/2 Corex70 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good 208 SupplyandLayingof31/2 Corex50 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 209 SupplyandLayingof31/2 Corex95 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 210 SupplyandLayingof31/2 Corex25 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 211 Supply and Clamping of 2 core x 10 Sq.mm PVC armoured LTUGaluminium cable on post or on wall MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable. 212 Supply and fixing of brass cable gland for 2 x 10 sq.mm. PVC armoured LTUG cable with earth connection 213 Supply and fixing of brass cable gland for 3-1/2 x 25 sq.mm. PVC armoured LTUG cable with earth connection 214 Supply and providing cable end termination of 3-1/2 x 25 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 215 Supply and fixing of brass cable gland for 3-1/2 x 50 sq.mm. PVC armoured LTUG cable with earth connection 216 Supply and providing cable end termination of 3-1/2 x 50 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 217 Supply and fixing of brass cable gland for 3-1/2 x 70 sq.mm. PVC armoured LTUG cable with earth connection 218 Supply and providing cable end termination of 3-1/2 x 70 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 219 Supply and fixing of brass cable gland for 3-1/2 x 95 sq.mm. PVC armoured LTUG cable with earth connection 220 Supply and providing cable end termination of 3-1/2 x 95 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 221 Supply and fixing of brass cable gland for 3-1/2 x 120 sq.mm. PVC armoured LTUG cable with earth connection 222 Supply and providing cable end termination of 3-1/2 x 120 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 223 Supply and erection of GIHotDip/PowderCoated16SWGPerforated type CableTraywith 300mm width and 50mm height with all the fixing accessories 224 Supply and Run of 2 of 2.5 sq.mm.PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable gauge MS conduit pipe Concealed inwall and ceiling with continuous earth wire connection of 2.5 sq mm copperwire and making good of the concealed portion 225 Supply and Run of 2 of 6 sq.mm.PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable gauge MS conduit pipe concealed inwall and ceiling with continuous earth wire connection of 6 sq mm copperwire with painting of suitable colour. 226 Supply andrunof2 of4 sq.mm. PVC insulatedSC unsheathedFRLS copperconductorof1100V gradeinsuitable heavy gauge MS conduit pipe concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm copper wire and making good of the concealed portion wiith suitable colour 227 Supply and fixing of 1 no.6A two module 5 pin socket , 1 no.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 228 Supply and fixing of 2nos.6A two module 5 pin socket , 2 nos.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 229 Supply and fixing of 1 no.6/16A two modulesocket , 1 no.16A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 230 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End (Primary) 231 Supply and fixing of 18W LEDRound type Recessedfitting with LED (Higher end) on false Ceiling from ceilingwith PVC unsheathed copper leads from terminals to the fitting. 232 Supply and erection of 20Watts, 4 Feet LED Fitting with LED (Higher end) end cap, PVC unsheathed copper leads from terminals to the fitting and fixing accessories 233 Supply and fixing of 60Watts All-in-One (AIO) Model Solar Street Light with 6000mm Height pole with base plate and all the fixing accessoriesThe cost is inclusive of civil foundation works including anchor fasteners,etc., as per site requirements 234 Supply and fixing of 3W RGB Light fitting (IP67) Inground fixture with PVC unsheathed copper leads from terminals to the fitting and to complete necessary accessories and etc to complete the work. KLITE:4092 - symmetrical Inground 235 Supply and fixing of spike light 6W fitting on floor with PVC unsheathed copper leads from terminals to the fitting and to complete necessary accessories and etc to complete the work. KL-Trioscope - 7052 236 Supply of One No of 9.5 mtr. Street Lamp Post With 2.7 mtr Arch Double Bracket, 1 No. of 4 Core SMC Fuse Box With Hot Dip Zinc Galvanising 237 Cost of Erection & Materials Required For 9.5 mtr Street Lamp Pole With Brackets Conventional Foundation(Material Ratio - 1:1.5:3) 238 Supply and fixing of 300mm (12) sweep(Heavy Duty) AC exhaust fan complete with necessary wall opening and making good of the wall . 239 Supply and fixing of MS / Fibre Louvers Shutters arrangements for 300mm ACExhaust Fan (M-1346) 240 Supply and fixing of 1200mm (48) sweep AC ceiling fan 5 star ratedcomplete ( Higher end)with 2 module 100W fan step regulator (Higher end)with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18) 241 Supply and fixing of Maintenance Free earthing with Copper rod of 17.2 mm dia and 3m length including all the civil works 242 Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection 243 Supply and Run of1 of No.8 SWG copper wire for earth connection 244 Supply and Run of1 of No.8 SWG copper wire in suitable PVC rigid pipeon wall / floor / ground for earth connection 245 Supply of 2mx1mRubberMatsuitablefor11KVinstallation confirming to IS 246 Supply of First Aid Box complete with all First Aid Medicines 247 Supply and fixing of Shock Treatment chart with Glass frame(in English & Local Language) 248 Supply and fixing ofMetallic Danger Board as required by the Electrical Authorities (415Volts & 230Volts) 249 Supply and Installation for 2KVA, UPS (Single Phase Input & Single Phase Output) Capacity with 2Hourse Battery back up, battery stand and interconenction cables. 250 Supply and fixing of 40Amps, 30mA DP RCCB in a suitable sheet steel enclosure and necessary fixing accessories (Higher end) 251 CCTV SYSTEM 252 Supply, Installation, Testing and commissioning of 32 channel 8 SATA NVR, with 10TB Hard Disk Drive 2 nos, New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected,Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output  HDMI1 / VGA1 outputs provided  HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface for HDD connection, Support upto 10TB capacity for each HDD, Smart search for efficient playback. and smart playback to improve the playback efficiency, Supports VCA search for fire/ship/temperature/temperature difference detection triggered video files, POS information overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access  Hik-Connect for easy network management, 2 Gigabit Ethernet network interfaces. 253 Supply of 4MP, Internet Protocol fixed BULLET CAMERA (OUTDOOR) with following specification:a) 1/2.5 Progressive Scan CMOS, b) 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behavior analyses ( Line crossing detection, intrusion detection)c) Face Detection d) 120dB WDR, e) BLC/3D DNR/ROI, IP67 compliedff) On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,g) Shutter Speed 1/3 s to 1/100,000 s, h) 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, i) rotate: 0° to 360°, 2.8 mm, j) horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, k) Lens Mount M12 & IR Range I5: up to 50 m, l) Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, m) Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9Wn) Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse. with Camera Stand. 254 Supply of 8MP, Internet Protocol fixed BULLET CAMERA with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behavior analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse with suitable Stand. 255 Supply, Installation, Testing and Commissioning of 55 smart LED TV with following specifications a) Resolution: Ultra HD (4K) 3840 x 2160b) IPS panel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -2nos n) Built in LAN o) Magic remote 256 Supply and Clamping of CAT 6 unarmoured cable in suitable PVCPipe 1 thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem)i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal)IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-TIEEE 802.5 16 MB; ISDN; TPDDI; ATMii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant.Fire Rating: PVC : IEC 60332-1.iii. Conductor - Bare Copper Wireiv. Insulation - Polyethylene v. Twisting - 2 Cores to the pair vi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm. 257 Supply and laying of armoured, Multimode, Thermoplastic Tape Inner Sheathed, PVC type sheathed 6 core Optical Fibre Cable withunique fiber excess length control method provides the cable with excellent mechanical and environmental properties and Cable - 2 Embedded FRP provides tensile strength & Anti-buckling properties. It is processed with Filling jelly - Thixotropic jelly to prevent Water ingress in loose tube. 258 Supply and Termination of Optical Fibre Cable Single Point ( Point to Point ) Splicing and arrangement charges. 259 Supply and fixing of POE 8port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. 260 Supply and Fixing of Rack with Accessories -Higher end6U Rack with fan extra for the above rack. (speaker/data/cctv) 261 Supply and fixing of POE 24 port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. 262 Supply, Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point ( Point to Point ) Crimping, Testing and arrangement charges. 263 Supply and fixing of outdoor 4X6PVC box with 102mmX77mmX102mm with all fixing accessories. 264 Supply and Erection of 6mtrLengthpole with base plate of size 300x300x12mm as per IS-875 with following specification. Pole Outter dia -76.10mm x 3.65mm Thick x 6 meter with foundation Charges.The Pole Should be hot dip Galvanized confirming to BESN ISO-1461 with thickness of 65 Micron 265 PA SYSTEM 266 Supply, Installation,Testing & commisioning of 30 watts 2 way high efficiency, high fidelity, long throw IP65 weather proof P.A Music Horn WALL / COLUMN speaker. It combines the high efficiency of horn with wide frequency response.Music horn is weather protected and UV protected ABS plastic housing combines with the feature of easy poertap selection on a terminal strip with a two core cable.It has impedence of 250/500/1k/2k ohm with frequency response of 120-16000 hertz. 267 Supply, Installation,Testing & commisioning of 480 watts P.A Booster Amplifier with the output power of 1350 watts maximum, 500watt rms at 10% Thyristor harmonic distortion(THD), 850watt RMS at 5% THD, 800 wattsRMS at 2% THD and the power supply AC voltage ranging from 220-240 volt, 50/60 hertz. with the DC input of 48 volt and 1000watts has tone controls of Bass=+- 10 db at 100 hz weighing 42kg with the speaker output of2Q,4Q.70volt&100volt has power consumption of 1600VA AC &12A DC and 100db output regulation at 1khz no load to full load ratio. The signal to noise ratio is 60db with the imnput channels of 0.8mv/4.7kq,3*Aux 100mv/50kq.The frequency response of 50-15000hz+-3db. 268 Supply, Erection,testing & Commisioning of custom built table top 4 zone micro processor based 1 way announcement console cinsisting of teleline preamplifier , 1 x priority module , 12 zone selector module , all call switch module , tone oscilator modulefor fire evacation, press to talk switch module,goose neck microphone ,24v dc rectifier module, power supply uit , all call relay module etc as required.(Delegate unit) 269 Supply and Fixing of Rack with Accessories -Higher end6U Rack with fan extra for the above rack. (speaker/data/cctv) 270 Supply, run, testing and commissioning of2Core x 1.5sq sqmm PVC insulated Armoured Speaker Cable in suitable 25mm dia Pvc Rigid pipe concealed on wall and ceiling with continuous earth wire connection with painting of suitable colour.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
27.
Housing Urban and Rular Development #10200585 Price Bid
Tender For Construction Of New Muthalvar Padaippagam At Bhakthavachalam Park, Chennai; 1 Civil Works 2 Dismantling removing the existing Reinforced Cement Concrete work etc., by using required mechinaries includingdisposal of unserviceable material, labour charges, as per direction of Engineer in charge. 3 Dismantling removing the existing Brick work etc., by using required mechinaries includingdisposal of unserviceable material, labour charges, as per direction of Engineer in charge. 4 Removing the existing ventilators,doors and windows including removal of frames ,hinges and fastenings arefully and stacking the same at site etc., complete. 5 Dismantling Floor finish and daddoing walls in cement mortar with mosaic tiles/glazed tiles/cuddapah slabs. 6 Carting away the surplus earth and debris to a lead of 5kgm.including Loading, unloading and dumping in the Corporation Land as directed during the execution. 7 Dismantling removing the existing closet, fitting, pipes, etc as per site., by using required mechinaries includingdisposal of unserviceable material, labour charges, as per direction of Engineer in charge. 8 Civil Works 9 Providing and constructing cast in situ hydraulic bored piles of specified diameter in M30 grade concrete using blended cement - slag cement with minimum cement content of 400kg/m³in accordance with the structural engineers drawings and directions, but exculding reinforcement including cost of mobalization of all necessary plants, equipments like piling rigs, temporary casing of appropriate length forsetting out cardinal points and the removal of the same, boring in overburden, using bentonite mud circulation technique or any other method dulythrough all strata upto the foundation level of piles etc., complete all as approved by the departmental engineer. Further include dewatering, placing concrete by tremie pipe method, disposal of bored material outside the site. Including Chipping carefully cut off portion of piles as required without any damage to the piles and dressing the top and removing all the debris away from the site with out any extra cost as directed including the cost of all tools, plants, conveyance, all labour, lead and lift required etc .,Conducting standard penetration test to identify the refusal strata for atleast 1 pile in group and atleast 25% of piles, comparing with refusal strata as indentified in soil report and providing socketting into refusal strata by 1.00mt or into hard rock by 100% dia of the pile. (Length of pile for payment shall be measured up to bottom of pile cap). 10 Boring or chiselling through any obstacles, boulders, weathered rock, etc. Upto founding level of piles for seating resting or socketting of files. The rate quoted shall include demobilising the site with all plants, equipment, piling rigs, necessary personnel brought for piling work, including removal and transportation of debrise away as directed, cleaning and reinstating site to original condition as acceptable by the Architect on completion of piling work. 11 450 mm Dia 12 Carrying out initial working pile load test on specified dia piles as specified in IS:291 1 (Part 4). Includes all plant, equipment, machinery. Instruments, measuring devices, platforms and kentledge pile caps etc., dismantling and carting away entire setup, excavation and dewatering etc., all complete 13 Earth work excavation for all foundations in all type of soils and sub soils to the required depth for Footings, plinth / grade beams, etc,. by mechinaries including manual excavation for the following type of soil / rock as per detailed specification. As per SS 20B as hard rock requiring blasting inclusive of shoring strutting and baling out water wherever necessary and including refilling 0 to 2.0m depth consolidation depositing the surplus earth in places shown clearing and leveling the site with an initial lead of 10 metre and lifts as specified hereunder etc., complete in all respects complying with relevant standard specification and as directed by the departmental officers. 14 Supplying and filling of Gravel / Good Earth by lorry in Foundation basement filling and site filling with approved materials excavation from approved quarries and compacted to meet requirement of table 300-1, 300-2 of MORTH, in layers not exceeding 300 mm loose thickness, spreading, breaking clods, removal of roots and other organic materials to the required line, grade and cross-section including watering, spreading by Dozer, grading by motor grader and consolidation by vibratory road roller with desired field density not less than 95% of maximum dry density ,including all lead,lift, loading, unloading, all labour, hire charges of all machineries, Transportation, etc., complete in accordance with MORTH technical specification clause No. 305 and with all other incidental charges and as per the direction of the Engineer-In-Charge. 15 Providing Pre construction Anti termite treatment for the building including all chemicals as per standard specifications. Labour charges for preparing the areas for treatment spraying chemicals and other incidential charges etc., complete. The rate shall be inclusive ofgiving anti-termite treatment to the building for the following four stages including breaking the termite mounds making holes with crow bars at an intervel of 12to a depth of 8 in the periphery of building and pouring chemicals etc., complete as per ISI 6313-1981 and. The antitermite chemicals used should have 0.5% concentration with 3L solution for the entire operation etc. as directed by the Engineer incharge and including cost of chemicals labour transportion etc., 16 Stage:1 Spraying Anti-termite treatement chemicals solution for the foundation before laying the foundation concrete bottom and sides of the foundation. 17 Stage:2 Spraying anti-termite chemicals solution to the grade beams level spraying has to be done for the grade beams brick masonry in the superstructure in contact with back fill earth. 18 Stage:3 Spraying anti-termite chemicals solution on sand for the flooring before laying the flooring concrete. The treatment has to be carried out on the sand filling the basement after leveling operation is over. 19 Stage:4 Spraying anti-termite chemicals solution around the building outside of the building by making crow bar holes at an intervel of 12 to a depth of 8 around the building before laying the plinth projection.This holes has to be be closed after the treatment. 20 Supplying and Filling withM-sand in floor and others sub structures for 150mm thick and well watered, rammed and consolidated by power compacter. The rate includes the cost of river sand, compacting with mechanical compactors, labour charges for leveling, loading & Unloading and Transportation charges etc., complete and as per the standard specification. 21 Construction of Wet Mix Macadam 150mm compacted thickness in two layers by providing , laying , Paving , and compactingofaggregate gradation satisfying to Table 400-13 of MORTH and satisfying the physical paraeteres as per MORTH Table 400-12, mixing in a Wet Mix Plant of 200 tonne capacity at OMC , carriage of mied material to work site and laid in sensorpavers to the required line and grade as per the drawing and compacted with vibratory roller of 8-10 tonne to achieve the desired density of 98% of Maximum dry density and as per the direction of the Engineer-In-Charge of work. 22 Providing and laying plain cement concrete 1 : 4 : 8 ratio of(1 cement , 4 sand and8 graded stone aggregate 40mm nominal size) in foundation and basement for 100mm thick including dewatering wherever necessary and consolidation etc. The rate includes the cost of materials, labour charges, lifting charges, loading & Unloading and Transportation etc., complete and as per the standard specification. 23 Supplying and erecting centering for sides and soffits including supports and strutting up to 3.30 m height with all cross bracing for plane surfaces as detailed below, using mild steel sheets of 90 X 60 cm 10 gauge stiffened with MS angle of 25 X 25 X 3mm for boarding, laid over adjustable span & jacks and supported by 50mm dia pipes for general pipes scaffolding systems @ a spacing of 1.20m c/c and vertical connected at a height of 2.0m c/c including C & U clamps and base receiver cup at bottom for connecting pipes etc and removable systems etc., the rate including cost of all materials, labour charges, wastages, placing, transportation, lead & lifts, tools & plants, fuels, fixing in position at all levels, heights, masking tape in sheet joints, consumables, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 24 For column footing plinth beam , pile cap staircase steps, piers raft beam raft slab etc., 25 For Plain surfaces such as RCC slab, Beam, Bed Block, waist slab, landing slab, lintel etc., 26 For square or rectangular column, boxing, sunshade etc., 27 Providing and Laying M 30 Standardised concrete Mix for all reinforced cement concrete with minimum cement content conform to IS 456-2000 using ordinary Portland cement of grade 53 from approved manufacturer, manufactured sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement. works for Footings, Grade beam, retainning wall drain wall & raft , Plinth beams, Column, Grade slab, Roof slab & beam, Column drops, Pergola, Staircase waist and landing slab lintel, Sunshades, parapet Cum drops, Steps, canopy, window boxing slab, Loft, fins facia Planter box, machine foundation, elevation features and other similar structures etc..excluding necessary centering, shuttering and reinforcement which shall be measured and paid separately under relevant items. in-charge The rate including cost of all designing the mix, batching plant, mechanical mixing, transporting and placing at all levels, leads, lifts, tools & plants, fuels, all materials, labour charges, wastages , laying, pumping the concrete to all levels, providing sleeves / openings in RCC slabs, compaction by vibrator, gunny bags for curing etc. as complete with all respects complying with relevant standard specification, as directed by theEngineer-in-charge 28 Basement 29 GF 30 FF 31 Terrace 32 Supplying, fabricating and fixing in position of steelFe 550 grade Reinforcement for all RCC work with Thermo Mechanically Treated Bars (TMT) conforming to IS 1786 of latest version according to drawings and binding the reinforcement with 18 gauge double fold GI binding wire and providing Concrete cover blocks to maintain the cover as required. The rate including cost of all materials, bending, tying grills, placing, transportation, lead & lifts, tools & plants, fuels, all materials, labour charges, wastages , laying at all levels, fixing in position, cost of cover blocks and GI binding wires etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 33 Brick work in cement mortar 1:6(one cement and four sand) using fly ash bricks of size 230mmx110mmx70mm for foundation and super structure as per detailed specifications and as directed by the departmental officers 34 Ground Floor 35 First Floor 36 Terrace 37 Brick partition walls of 11.50cm thickness using best quality Fly ashbricks of size 9 x 4-3/8 x 2-3/4(230x115x76) in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) 38 Plastering 10 mm thick for ceiling including slabs, beams and column drops and staircase waist slab, sunshade, drops, chajjas etc.. with cement Mortar 1:3 (1 of Cement : 3 ofP sand) according to the specification. The Rate including Cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 39 Plastering of 12 mm thick for Internal walls with cement mortar 1:4 (1 of cement : 4 of fine P.sand)according to specifications. Rate shall include for providing GI mesh of nominal thickness at the junctions of masonry and concrete works to a width of 100 to 125mm including tying in position with suitable clamps/screws. Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 40 Plastering 12 mm thick for external surfaces with cement mortar 1:4 ratio (1 of cement : 4 of fine P.sand) including water proofing compound of “CICO No.1 or equivalent“ as per Manufacturers Specification with sponge finish (washed sand finish) all complete as per specification and as directed.Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds, grooves to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by theEngineer-in-charge. 41 Supply and painting oftwo coats of Plastic emulsion paint of approved shade and colour over one coat of DCP Primer including one coat of Acrylic Wall Putty with DCP Primer.Rate including all brush, roller, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations,transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by theClient / Engineer-in-charge.(Internal surface) 42 Supplying and painting of2 coats of weather proof exterior emulsion with high sheen, anti algal properties over one coat wall exterior primer of approved quality and shade etc., complete.Rate including all brush, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations,transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 43 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete (M-0652) 44 Supplying and filling the sunken slabarea byBRICK-BATCOBA by adding CICO NO:1 or approved equivalent admixture including applying two coats not less than 2 mm thick of TAPECRETE- AcrylicPolymer Based Waterproof Coating, over the final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with water proofing compound like CICO No.1 at the rate specified in the manufacturers specification after entire completion of laying pipes, sanitary fittings etc.Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, protecting the laid pipes and sanitary fittings, finishing the surface smooth to receive the top coat of water proofing application etc. as complete with all respects complying with relevant standard specification and as directed by theClient / Engineer-in-charge. 45 i) Includingapplying two coats not less than 2 mm thick of TAPECRETE- AcrylicPolymer Based Waterproof Coating, over the plastered surface as including final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with approved water proofing compound like CICO No.1 or approved equivalent conforming to IS 2645 at the rate specified by the manufacturer over coated surfacepreparation of surface, finishing, curing etc. all complete at all levels as per manufacturers specifications and as directed. 46 Supplying and laying of Ceramic tiles of size 305 x 305 x 6mm for flooring approved make and quality with plain/colourwith base mortor in CM 1:3, 10mm thick and pointing with white cement by adding suitable colour pigments including finishing, jointing and polishing with neat finish etc., complete. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 47 Supplying and fixing Dadooing the wall with ceramic tiles of approved quality, colour and design joint free of size 600x300x10mm thick of approved make, in all floors over a base layer of cement mortar 1:2 (one cement: Two sand) 10mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 48 Providing and laying factory-manufactured linoleum flooring in the form of Rolls in the size of 12192mm of length and 1981mm of wide with 2mm thickness which laying above in the vertified tiles using the adhesive the flooring shall be laid over a smooth, level subfloor using manufacturer-recommended adhesives, complete in all respectsRoll flooring shall be laid with butt joints; edges shall be cold-welded or heat-welded for seamless joints.Apply a coat of linoleum polish or sealant after laying (if uncoated variant is used). Proper rolling to remove air pockets and ensure bonding the rate is inclusive of all necessary material, labour, transportation etc asper standards. 49 Finshing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in cement Mortar 1:3 (one cement and threee sand ) 12mm thick mixed with water proofing compound conforming ti ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed withred oxide and water proofing compound including curing et,. complete complying with standard specification and as directed by the departmental officers 50 Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete. 51 Supply and laying with best quality the following materials of Machine Polished granite slab not less than 18 mm thick (Jet Balck) including cutting for wash basin and edge polishing to be set in CM 1:4 (1 of cement : 4 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts working at all levels, transportaion charges, loading & unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing,cleaning, acid wash over finished surface, protection with Gypsum / Poplayeroverplastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge 52 Supplying and fixing plywood partition with Teakwood frames of75x50mm size and with 3mm thick commercial plywood fixedwith screws and nails including fixing in position with 4Nos of iron hold fasts 50x6x230mm size etc.,complete.(ISI STD) 53 Supply & fixing of Tamilnadu Logo & Symbols as per design & Elevation. 54 Flooring with Joint free double charged vitrified tiles of approved quality, colour and design joint free of size 600 x 600 x 8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officers. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by theClient / Engineer-in-charge. 55 Supplying and fixing UPVC windows of casement type Open from the profile the size of outer frame 60mm x58mm and shutter profileare reinforcement withGI/1mm125GSM and 100% Corrosion free,the profiles are multi Chambered sections with wall thick of 2mm. TheEPDM rubber covered with over all the edges of frame and shutter the shutter .will be provided with Espag multi power point locks and also it operates with Handle. The Corners and joint should bewelded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thk should be provided to the shutter and it should not allow leakege of water even at most ranging storms and should have key lockable action, security protective hinges , strong locking system and as per size for arresting noise and energyloss. The connecting mechanism between sash and windowshould be fixed to the wall with 100% packing with screws and silicon Packing all roundthe frames. The window should be got approved from the Executive Engineer before use on work. 56 Providing of 35mm thick factory made pre-laminated ABS(Acrolynitrile Butadiene Styrene) Door Shutter moulded indifferent designs, consisting of all round frame made out of water proof solid foam PVC bar of size 20 x32mm, reinforcedby 32 x 32mm - 2 Nos., for vertical made out of LVL(Laminated Veneer Lumber), core material of 32mm thickhigh density craft paper honey comb board, sandwiched onboth sides with pre-laminated ABS sheet thickness of 1.5mm.PVC edge banding of size 0.45mm on the vertical sides.Hardware made out of steel coated butterfly hinges - 3 Nos.,for each shutter and ISI make SS round lock complete forfinished item of work, complete complying with the standardspecification. The door shutter and frame should be gotapproved from the Executive Engineer before use on work. 57 FRP Door Sutter with FRP Door Frames along with vision panel (as per drawing) made out of FRP Sheets of 3mm thick of over all size 65mm x 50mm with rebate suitably reinforced using MS Angle / Flats, cost of holdfasts and Solid Core FRP Shutter Panel of 5mm thick and hollow core frames of 3m wall thickness for styles and rails etc., of sizes specified by Engineers. 58 Supplying and fixing UPVC Louvered Ventilators of from the profile the size of outer frame 60mm x58mm and shutter profile size of 60mm x 78mm both profile are reinforcement withGI/1mm125GSM and 100% Corrosion free,the profiles are multi Chambered sections with wall thick of 2mm.The EPDM rubber covered with over all the edges of frame and shutter . The Corners and joint should bewelded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thk should be providedin the Louvers.The window should be fixed tothe wall with 100% packing with screws and silicon packing all round the frames.The Ventilator should be got approved from the Executive Engineer before useon work. 59 FALSE CEILING WITH GYPSUM PLAIN TILES (600x600)Providing and fixing true horizontal level false ceiling using SAINT - GOBAIN GYPROC or Equivalent make with 24 mm Grid system using hot dipped galvanised Steel Section, exposed surface chemically cleaned caping prefinished in backed polyestar paint wall angle of size 24mmX24mm used in the periphery of the ceiling fixed to the wall partition R.C. Column bandwalls with the help of screws at 600mmc/c. Main runner of size 32X24mm suspended at 1200mm c/c max by using securely fixed to the structural soffit of R.C.C. slab by using 6mm Nylon Rawl plug at every 1200mm(Max) and 1200mm long Cross Tee of size 24X24mm to interlocked between Mainrunner at 600mm c/c (max) to form a grid of 1200mmX600mm. 600mm long Cross Tee of size 24X24mm is inserted to form a grid of 600mmX600mm and finally tiles laying with 12mm Gypsum plain Tiles as per stansdards 60 Providing & fixing of Brick Cladding in elevation as per drawing. The rate is inclusive of all necessary material , labour, transportation etc complete as per standards. 61 Supplying and Fixing of aluminium Dye Cast Letters of approved size and colour treatment processis achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes aluminium Dye Cast Letters 6 Size. Tamil Stainless Steel Letters 25CM 62 Supplying and fixing M.S.Grill gate of required size in two shutters with necessary iron members, gun metal cups and wheels 75mm dia. with fittings locking arrangements,etc., complete,including painting a priming coat of approved primer,etc., complete (The design of gate furnished is subject to alteration during execution.) 63 Supplying and Painting the wall with Texture Finish Paint including thorough scraping, clean removal of dirt, Primer. The rate includes cost of materials, brushes, sand paper, rollers, plaster of parries, putty wherever required and neat finishing etc., complete complying with standard specification and as directed by the Departmental Officer (the colour and quality should be got approved by the Executive Engineer before use) 64 GYPBOARD DOUBLE SKIN PARTITIONProviding and fixing of Gypsum Dry wall Double skin partition of 75 mm thick using SAINT - GOBAIN GYPROC or Equivalent make and the partition shall be of one layers of tapered edge 12.5mm thk Gyp board screw fixed with dry wall screw of 25mm at 300mm c/c to either side of 48mm studs. GI steel sections to be placed at 610 mm c/c in 50mm floor and ceiling channel 0.55mm thick having equal flanges of 32mm made of GI steel with joints staggered to avoid leakage through joints. Finally square and tapered edges of the boards are to be finished so as to have a flush look which includes filling and finishing with jointing compound, joint paper and 2 coats of Drywall top Coat suitable for Gypsum upto primer level.As per India Gypsum Specs.Note: Angle Bead to be used at external angles to get straight line finish & protection from normal impacts. 65 Providing and laying water proofing treatment to vertical and surfaces for sunken portion of depressed portions of W.C., and the like consisting of :i) 1st course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) 2nd course of 20mm cement plaster 1:2 (1 Cement : 2 Coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) 3rd course of applying blown or residual bitumen applied hot at 1.7Kg per sqm of area. iv) 4th course of 400 micron thick PVC Sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm) 66 PLUMBING WORKS 67 Supply,erection and testing & commisioning of 3HP Submersible pumpset in the capacity of 6000 LPH @ 300Ft, max. total head of 350 Ft pumps fitted with bronze impellers and having delivery size of 40mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge.( Sump to OHT transfer pump) 68 Labour charges for the erection of submersible pumpset in borewell/openwell including fixingand jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days. 69 Drilling of 6 dia vertical borewell so as to have a finished size of 6 dia borewell in boulder area to any required depth as decided by theincluding Transportation from one place to anothr place with in Tamilnadu State by direct or reverse rotary mud circulation method using Contractors rig tools, fuel, labourers, bentonite mud and water required for drilling at the site shown by the TWAD Officers including construction of mud pit etc. using only calyx rigs. 70 300mm 71 Charges for developing the borewell with air compressor of 300 CFM capacity (Minimum 8 Hours) including transportation labour and fuel charges for compressor as directed by TWAD Board Officers and conducting yield test by V notch method. 72 Supply and laying following dia PVC casing pipe with excise duty as per IS 12818 / 1992 73 200mm dia CS ( plain pipe) 74 150mm dia CS ( plain pipe) 75 Labour charges for inserting PVC casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC couplers with cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the Executive Engineer of Departmental officers. 76 200mm dia CS ( plain pipe) 77 150mm dia CS ( plain pipe) 78 Supply and fixing in position whiteEuropean Water Closet of approved make with low level concealed flushing tank 10 litre capacity of best quality and approved make with 100mm P or S trap with double flapped rigid PVC seat cover with CP brass hinges etc. complete complying with standard specification and as directedby the Departmental officers (The EWC should be got approved by the Executive Engineer before use on works.URINAL WITH FIXING ACCESSORIES SET, SIZE - URS-WHT- 13253N 79 Supplying and fixing Wash Hand Basin of size 550 x 400mm with all accessories such as cast Iron Brackets, 32 mm Dia C.P. Waste coupling, Rubber plug and Chain, 32 mm dia B Class G.I. Waste pipe, 15 mm Dia G.M Wheel valve; 15 mm Dia Nylon connection, 15 mm Dia Brass, wast couplingNipples, 15 mm C.P. Pillar tap etc.,including fixing the wash hand basin in the wall in position with a pair of C.I. brackets with teak wood plugs and screws and giving necessary water supply connection and as directed by the Department officers.(TheWash basin should be got approved by the Executive Engineer before use on works. 80 Supplying and fixing of CP Two Way Bib Cock with Health Faucet ,wall hook & one metre longflexibletubeincludingcuttingandmakinggoodthe wallswherever requiredetc complete.complyingwithstandardspecificationandas directedbytheDepartmentofficers.Thequalityandmakeofhealth faucet should be got approvedby Concern department Engineer before use on work. 81 Supplying and fixing the best quality approved make of SS heavy duty long body Tap including cutting and making good walls wherever required etc.complete,complying with standerd specification and as directed by the department officers. The quality and make of angular stop cock should be got approved by concern department engineer before use on work. 82 Supplying and fixing in position Mirror of size 600x450mm of approved quality and brand with necessary plastic back PVC frame with bottom stand using brass screws rawl plugs for fixing etc complete complying with standard specification and as directed by the Departmental officers.The colour of frame and quality of mirror should be got approved by the Executive Engineer before use on work 83 Supplying,installing,testing and commissioning of approved make CONCEALED STOP COCK for toilet including neccesary accessories etc,complete,works include making require size curout in wall,and fixing the control box property,redoing the same etc,complete the quality and make of concealed stop cock should be got approved by concern department Engineer before use on work. 84 Supplying and fixing CP angle cock with wall flange including cutting and making good the walls wherever required etc., complete complyingwithstandardspecificationandas directedbythe Engineer Incharge before use on work. 85 Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg ,10 kg /sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). 86 160mm Dia 6kg 87 110mm Dia 6kg 88 75mm Dia 6kg 89 50mm dia 6kg 90 Supplying andfixingPVC cowl of following size to vertical Soil/Waste pipes above terrace level. The rate including cost of all materials, labour charges and transportation etc. completed as directed by Engineer-in-Charge. 91 110mm dia 92 Supplying & fixing in position PVC Nahini / Floor trap of size 100x75mm including stainless steel gratings of approved brand & quality, fixed over a bed of brick jelly limeconcrete 1:2:5 ( One part of lime, two parts of sand & five parts of 40 mm size brick jelly ) & finished with cement mortar 1:3 ( One cement & three sand ) includingdismantling masonry works wherever found necessary & making good the damaged portions to the original condition & giving connections to the cast iron pipes etc., complete, complying with standard specification. (The PVC Nahini / Floor trap should be got approved by the Executive Engineer before use on works ). 93 Constructing solid block masonry manhole various size of deep in cement mortar 1:3( 1 Cement: 4 coarse sand ) R.C.C. Raft & top slab with cement concrete 1:2:4, plain cement concrete 1:4:8 mixfor base course (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size )above that 150 mm thick RCC M25 raft slab inculding reinforcement 10mm dia 150mm c/c bothways. Plastering inside walls with 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand ) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ), finished with a floatingcoat of neat cement ,supplying and fixing SFRC manhole cover with farame , PVC foot rest as per detailed drawing etc the quoted rate shall also necessary excavation and back filling etc complete.complete as per standard design : (the chamber and cover should be got approved by the Executive Engineer before use on works) 94 Manhole 600 x 600 mm internal size ( Depth up to 1000mm) 95 Supplying, laying and jointing CPVC pipes SDR 11(having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using CPVC adhesivesand fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The CPVC pipes shall be got approved by Executive Engineer before use on works.Internal & Vertical 96 a) 20 mm dia 97 b) 25 mm dia 98 c) 32 mm dia 99 Supplying and fixing manhole cover with frame as per approved make ,cover weight and being size mentioned below and specified size in the drawing etc., including painting with two coats of anticorrosive paint over a coat of primer etc., fixing locking arrangements, fixing Man-hole over, grouting the anchors with CC 1:2:4 (one cement,two fine aggregate and four coarse aggregate), as complete in all respects complying with relevant standard specifications and as directed by theClient / Engineer-in-charge.Size:600x600mm 100 Supply & fixing of Bottle trap as per standards. BOTTLE TRAP (WITH INTERNAL PARTITION) 32 - ALD-CHR- 769L300X190 101 LANDSCAPING WORKS 102 Planting of Ixora hybrid foliage shrub variety of height 30-45 cm in polythene bag of size 6x8 inchincluding loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 103 Planting of Ficus black ornamentalfoliage shrub varietyof height 30-45 cm in polythene bag of size 6x8 inch including loading and unloading charges, transportation,stacking of saplings at site, earth work excavation ofrequired size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 104 Planting of Jasmine Plant foliage shrub varietyof height 30-45 cm in polythene bag of size 6x8 inch including loading and unloading charges, transportation,stacking of saplings at site, earth work excavation ofrequired size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 105 Planting of Travellers palm ornamental foliage Specimen plantvarietyof height 105-120 cm in polythene bag of size 16x16 inch including loading and unloading charges, transportation,stacking of saplings at site, earth work excavation ofrequired size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 106 FURNITURE WORKS 107 Linear type Workstation (1000mm(W) X 600mm(D) X 750+300mm(H)) as per below specificationTable Top: - Made of 25mm Thick E1 Grade Pre-Laminated Particle Board with 2mm PVC Edge Banding.Main Screen : -8mm Sandwitch Glass finishes of Sizes 1050x300mm htUnderstructure: - MS Square Leg cross-section of size 50 x 50mm is Made of Mild Steel 1.6mm thick CRCA Powder coated.MS Powder Coated horizontal Beams supported below the table top of Size 50*25mm. Rectangular Tube made of 1.6mm thick CRCA Powder coated.Raceways : -Vertical Raceways - 120 MM HT MS Powder Raceways Considered below the Table top With Intermediated legs considered for Wire Provision.Without Middle Cover.Wire Manager: - Wire Manager Hole considered. 108 Storage (Open Shelf) 1200mm 300mm 2100mmIs made 25mm top & all other panel 17 mm thick in prelam particle board finished in Laminate of approved shape, equal shutter 2mm thick edge banding finished. This also includes providing and fixing of hardware like locks, handles, spring loaded hinges etc 109 Supply of Chairs 110 ASPIRE MB (BLACK)* Black Backrest frame, Polished aluminum connected* Mesh back, Seat and headrest fabric* Height adjustable lumbar support with PU surface* Tiltable backrest (can be tiltable when locked inupright position)* 4D adjustable armrest with PU pads* Mould foam with plastic seat upholstery* Mechanism, with seat slide.* Chrome gaslift* Polished aluminum base with plastic cover,* 60mm nylon castors 111 * Versa Medium Back Mesh Chair* AN -70 Mesh* Single Lock Synchro Mechanism* Adjustable Lumbar Support* One Way Adjustable Armrests ( Height)* Nylon Base* Fabric Upholstered Cushion Seat 112 Meeting Room TableTable Top: -Made of 25mm Thick E1 Grade Pre-Laminated Particle Board with PVC Edge Banding,Understructure: - MS Leg 50mm 50mm is Made of Mild Steel 1.6mm thick CRCA Powder coated.MS Powder Coated horizontal Beams supported below the table top of Size 50*25mm.Raceways : Horizontal RacewaysMS Powder Raceways Considered below the Table top With Intermediated legs considered for Wire Provision.Wire Manager:- Flip Cover Considered. 113 Meeting Room Table (2400mm 800mm 750mm) 114 Cabin Main Table with Side Storage (Main Table 1500mm 750mm 750mm / Side Storage 1200mm 450mm 750mm)Side Storage 1200mm 450mm 750mmTable Top: Main and Side Table Made of 25mm Thick E1 Grade Single Top PLPB with 2mm PVC Edge Banding,Understructure: MS Square 50mm Steel 1.6mm thick CRCA Powder coated.MS Powder Coated horizontal Beams supported below the table top of Size 50mm x 25mm.Flip Cover : Flip Cover 400*143mm Made of AluminiumWire Manager: Wire Box with Socket Plate and Vertebra considered for wiringModesty : Front & Side PLPB Modesty Panel . 115 Librarian TableMain Table 1100mm 440mm 750mm 116 3 Seater Sofa with Table 117 INTERACTS-902 (Leatherette)3 SeaterSize : 1810 (W) x 720 (D) X 740 (H)Made off : the sofa is made of fine quality leatherrite (3s = 8.0 mtr,2s = 6.8 mtr, 1s= 5.3 mtr), the structure is made from silver wood& pine wood, 32 & 40 density foam is used which is covered withroll poly filling for giving comfort and extra softness to sofa. Extra(kangaro company)Legs : are made of stainless steel.Color : Black 118 ELECTRICAL 119 TNEB METER BOX 120 Supply andfixng of TNEB meter board suitable for 3phase100A service connection made up of suitable angle iron frame work of size 2feet x 1-1/2 feet using angle iron of size1-1/2x1-1/2x1/4rigidly fixed on wall covered with hylem sheet of size 2 feet x 1-1/2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3Nos.100A fuse units (500V), 1No .neutral link,copper earth flat of size1x1/4with inter connection of EB meter to fuse units by 16 Sq.mm PVC insulated copper wire with earth connection complete. 121 M.S. Enclosure (IP65): Supply, Erection , Testing and commissioning of the followingtype M.S. powder coated enclosure for housing the Meteringing service, whch should be made outof16SWG enclosure with provision for cable entry, with Outdoorapplication IP65 as specified Protection, fixed on the wall/Floor withall accessories, pedestal frame with concrete grouting or suitable to fix at concrete plinth etc. 122 MAIN Panels 123 MAIN Panels:Supply, Installation, testing and commissioning of 3Phase, 415Volts, Main LT Panel board of Indoor, Cubicle floor mounting type made out of14 SWG CRCA sheet steel with powder coated finishing, MS base frame, double internal earthing arrangements, 100Amps, rating TPN Copper busbars and Earth bar with interconnection busbar, etc., comprising of the followings:EB Incomer :1 No. 100Amps, 25kA, 4Pole, Thermal magnetic MCCB with Ext.RHOMDG Incomer: 1 No. 100Amps, 25kA, 4Pole, Thermal magnetic MCCB with Ext.RHOMCommon C/O Incomer: 1 No. 100Amps, 4Pole Automatic Changeover Switch with EB ON and DG ON LED Indication lampsMetering : 2 Set of RYB LED Indication lamps2 Nos. of Multifunction Meter with RS 4852 Set of Current Tranformers (200/5A, Cl-1), 1 No. 200/5A CT for APFCR2 Set of Control MCB and Electrical Interlocking between EB & DG Incomers Outgoings: 3 Nos. 63A, 25kA, TP+N, TM MCCB with Ext. RHOM (APFCR &AC)4Nos. 32A, 25kA, TP+N, TM MCCB with Ext. RHOM (Lighting & Spare),6Nos 32A DB MCB inclding all labour Charges And Transports Charges. 124 APFC PANEL: Supply, installation, testing and commissioning of 25 KVAR Automatic power factor correction panel ( APFC ) with 8 steps of capacitor switching cubicle type, free standing, Powder coated, 14 SWG CRCA sheet steel,enclosed separate compartment for each capacitor, front operated, indoor type dust and vermin proof, hinged, lockable doors, electrolytic grade aluminium bus bars, with SMC /DMC insulator supports, Digital volt meter, Ammeter with selector switch, 8 stage Digital Automatic power factor correction,( APFC ), Auto / Manual selector switch, cluster LED typeindicators, in the incomer,complete with electrolytic grade aluminium bus bars, MPP type Power capacitors, with 5 KVAR x 3 no. 3 KVAR x 2 nos. 2 KVAR x 1 nos. 1 KVAR x 2no. Contactors, MCCB’s, start, stop, push buttons, internal wiring, colour coding, ferrules, cable gland plates, Aluminium earth bus for the entire length of the panel with bonding to earth and painting,Panel mounting MS Channels, fasteners, etc., including all associated control wiring and interlocking circuitry, Main panel sensing CT interconnecting wiring etc., all inclusive. 125 Supply, Installation, testing and commissioning of 1 x 58.5KVA, Silent type Diesel Generator Set with AMF Panel complete with suitable size Acoustic enclosure CPCB IV and BIS. Diesel Engine suitable for Generator application, developing 1500RPM with an overloading capacity of 10% for one hour in any 12 continuous hours operation generally confirms to BS:5514, directly coupled to 58.5KVA at 0.8 Power factor, 415V, 3Phase , 4wires, 50cycles per second self excited, self regulated, with brushless excitation, Alternator generally confirms to BS:5000/IS:4722. DG set shall be complete with radiator, residential type silencer, electronic governor, cable termination box, MS mounting frame, fuel piping, diesel day tank, 24VDC Battery, Battery mounting frame, oil level indicator with gauge board, andall other accessories as per standard specifications.Diesel Generator set shall be mounted on cushy foot or similar type of vibration Isolators. The cost of Exhaust pipe shall be included in this item with Sutable concrete Base at M30 Grade. The DG Set shall be suitable for auto-mains failure startand auto / manualoperations.The DG Should be supplied with Auto-Start-Stop Control panel with suitable rating switchgear 126 DISTRIBUTION BOARDS 127 Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1no. 32A DP MCBswitch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wallwith earth connection only.Higher End 128 Supply and fixing of 4 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution boardwith double door (metal) with 1 no. 32A 4P MCB switch as incoming and 12 nos. 6A to 32A SP MCB asoutgoing in flush with wall with earth connection only. Higher End 129 Supply and fixing of 7 segment 4 way TPN MCB sheet steel distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one no. 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one no. 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 4 ways in each segment) and seperate provision for MCB / Isolators ( totally 12 nos.) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm.with the following in flush with wall with earth connection only. i. 63A 4P MCB - 1 no.ii. 63A 4P 30MA RCCB/ELCB - 1 no.iii. 63A DP MCB Isolator -3 nos.iv. 6A to 32A SP MCB - 12 nos., 130 Supply and Laying of 3 1/2x 70 sq.mm. PVC armoured LTUG cablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 131 Supply and fixing of brass cable gland for 3-1/2 x 70 sq.mm. PVC armoured LTUG cable with earth connection. 132 Supply and providing cable end termination of 3-1/2 x 70 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete. 133 Run of Mains 134 Supply and Run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed position. 135 Supply and Run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed FRLS copper wire and making good of the concealed portion. 136 Supply and Run of 2 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed position. 137 Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion. 138 Point Wiring 139 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) Higher End Primary Point. 140 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator)Higher EndSecondary Point. 141 Switch & Sockets 142 Supply and fixing of 1 no.6A two module 5 pin socket , 1 no.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 143 Supply and fixing of 2nos.6A two module 5 pin socket , 2 nos.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 144 Supply and fixing of 1 no.6/16A two modulesocket , 1 no.16A one module switch with module cover plate (plastic) on Suitable module concealedBox (GI ) in flush with wall with connections. Higher End 145 Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug in flush with wall with earth connection (For AC Plug) 146 Air Condition 147 Supply & Instalation of Air-Conditioner with Copper Coil 2.0 TR Split Type AC Unit - 5 Star Rated, 5 KVA capacity Automatic Voltage Stabilizer with time delay relay, 5/8” and 3/8” copper pipe (Extra beyond 3 metres supplied with AC unit), Inculding MS stand for fixing outdoor unit. 148 Supply and fixing of Copper Refrigerant Piping of 3/8 dia and 5/8with Pipeline nitrle rubber insulation with 50mm PVC water drain pipe line with Non Adhesive Cotton Roll insulation and 3 core Power cable from indoor to Outdoor unit. 149 Supply and fixing of 450mm (18) Wall mounting 5 star rated complete (Higher end) with necessary accessories and hardwares as required. 150 Supply and fixing of 300mm (12) sweep(Heavy Duty) AC exhaust fan complete with necessary wall opening and making good of the wall . 151 Supply and fixing of louvers shutters arrangements for 300mm (12) sweep AC exhaust fan 152 Supply and fixing of 24W LED 2x2 square type Recessedfitting with LED (Higher end) on false Ceiling with suitable hanging support from ceilingwith PVC unsheathed copper leads from terminals to the fitting 153 Supply and fixing of 18W LEDRound type Recessedfitting with LED (Higher end) on false Ceiling from ceilingwith PVC unsheathed copper leads from terminals to the fitting. 154 Supply, installation, testing and commissioning of36 W, 900mm diaCircular LED pendantlight fitting, made out of CRCA powder coated body, aluminium reflectors,poly methyl meth acrylate (PMMA) diffuser, glare free light, suitable for recessed mounting including electronic drivers, day light colour LED lamps, inter connecting wiring including accessories all inclusive. KL 3232 155 Supply and fixing of28Watts GATE FIXTURE FITTINGwith cool day light suitable for wall / roof sheet mounting, made outCRCA powder coated body,IP65 aluminium reflectors,poly methyl meth acrylate (PMMA) diffuser, glare free light, including electronic drivers, day light colour LED lamps, inter connecting wiring with suitable fixing clams, hooks as required including accessories all inclusive.(Klite/Millenium/Bajaj Equivalent) 156 Supply and fixing of 8W Light fitting (IP67) Inground fixture with PVC unsheathed copper leads from terminals to the fitting and to complete necessary accessories and etc to complete the work. (Klite/Millenium/Bajaj Equivalent) 157 Supply and fixing of MIRROR Light 20W LED Batten 158 Supply and erection of Canon Digital Photocopier (Xerox) Machine IR-3300 / 3235Type of Product : Laser Multi functionalCore Functions: Print, Copy, Scan & SendFirst Copy Time:3.9 SecMultiple Copies :1 to 999 SheetsPrint Speed :45ppmThe laser beams engrave the image or text that you have sent to print on the surface of the drum. When using a copier this process is done using light, the light scans the page required for printing and converts it into an image 159 Supply and erection ofAll-in-one Desktop of HP 27-cb1456in Core i5 (8GB DDR4 /Windows 11 Home/27 Inch Screen/27-cb1456in) with 600VA UPS, Keyboard, Mouse,27 inches, 11th Gen Intel Core i5-1235U6 x 1.8 GHz (Turbo Speed upto 4.2 GHz) Cores Hexa Core, 12 Threads, 18 MB Cache, UHD Graphics 730 Graphics, 8 GB DDR4 RAM Smallest and 512 GB SSD.Ethernet (LAN), HDMI, Multi Card Reader,WiFi, Bluetooth v5.03 x USB 3.0, 1 x USB Type-C and Inbuilt Microphone 160 PRINTER: Supply, installation, testing and commissioning of HP Smart Tank 790 WiFi All-in-One Printer Duplexer with ADF and Magic Touch Panel Inkjet Colour printer, print speed 11-20 sheets with multiple features like print, scan, copy, fax, multi-port connectivity (Hi-speed USB 2.0, Wifi, Bluetooth LE , 1 USB Host, LAN) , 2.4/5G dual band Wi-Fi, Wi-Fi Direct, mobile printing capability, etc 161 Supply, installation, testing and commissioning of Long Range Wifi Device of following Specification: Networking Interface: (1) GbE RJ45 PortPower Method: PoE+, Pasive poE(48V) Max TX power: 2.4 GHzAntenna gain: 2.4 GHzMounting: Wall or Ceiling MountingWifi Satndards : 802.11a/b/gWireless security: WPA-PSK, WPA- Enterprises(WPA/WPA2/WPA3)VLAN: 802.1Q Concurrent Clients: 300+ 162 CCTV 163 Supply, Installation, Testing and commissioning of 16 channel 2 SATA NVR, with 6TB Hard Disk Drive 2 nos, New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected,Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output  HDMI1 / VGA1 outputs provided  HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface for HDD connection, Support upto 10TB capacity for each HDD, Smart search for efficient playback. and smart playback to improve the playback efficiency, Supports VCA search for fire/ship/temperature/temperature difference detection triggered video files, POS information overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access  Hik-Connect for easy network management, 2 Gigabit Ethernet network interfaces. (Make : Hikvision / Dahua / Sony. 164 Supply of 4MP, Internet Protocol fixed BULLET CAMERA/DOME CAMERA (INDOOR & OUTDOOR)with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behaviour analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse. with Camera Stand and camera fixed connecting box. (Make: Dahua/Panasonic) 165 Supply, Installation, Testing and Commissioning of 32 smart LED TV with following specifications a) Full HD 1920 x1080 (4K monitor) b) IPS panel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -3nos n) Built in LAN (Make: Sony/ LG /Samsung). 166 Supply and Clamping of CAT 6 unarmoured cable in suitable PVCPipe 1 thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem)i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal)IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-TIEEE 802.5 16 MB; ISDN; TPDDI; ATMii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant. ii)Fire Rating: PVC : IEC 60332-1.iii. Conductor - Bare Copper Wireiv. Insulation - Polyethylene v. Twisting - 2 Cores to the pair vi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm. 167 Supply and Fixing of Rack with Accessories -Higher end9U Rack with fan extra for the above rack. (Amp/NVR/POE) 168 Supply and Fixing of Rack with Accessories -Higher end4U Rack with fan extra for the above rack. (speaker/data/cctv) 169 Supply and fixing of POE 24 port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. (Make: DLINK,NETGEAR/ TPLINK) 170 Supply and fixing of POE 8 port switch with two uplink port, 10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. (Make: DLINK,NETGEAR/ TPLINK) 171 Supply and fixing of outdoor4X6PVC box with 102mm x 77mm x 102mm with all fixing accessories. 172 Supply, Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point ( Point to Point ) Crimping, Testing and arrangement charges. 173 Supply and Installation for 1KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2 Hours back up and battery stand . 174 Supply, Erection of 6mLengthpole with base plate of size 300x300x12mm as per IS-875 with following specification. Pole Outter dia -76.10mm x 3.65mm Thick x 6 meter with foundation Charges. 175 VOICE & DATA 176 Supply, Fixing and Termination ofRJ 11 Single Point ( Point to Point) Crimping, Testing and arrangement charges. 177 Supply & Installation of CAT 6 PVC Module Box I/o socket & face plate single socket Erection and arrangement chargers (Higher end) 178 Supply and fixingofLAN Network Switches Un-Managed 10/100/1000 - 24 Port and 24 Port Patch Panel- Unloaded erection and arrangement chargers. 179 Supply, runing, testing and commissioning of2 Pair Unarmoured 0.5mm Telephone cable in suitable Pvc Rigid pipe concealed on wall and ceiling with continuous earth wire connection with painting of suitable colour. 180 PA SYSTEM 181 Supply, Installation,Testing & commisioning of 15W Wall Speaker 2 way high efficiency, high fidelity, long throw IP65 weather proof P.A Music Horn speaker. It combines the high efficiency of horn with wide frequency response.Music horn is weather protected and UV protected ABS plastic housing combines with the feature of easy poertap selection on a terminal strip with a two core cable.It has impedence of 250/500/1k/2k ohm with frequency response of 120-16000 hertz. (Make:AhujaAMH402T/Bosch or its equivalent) 182 Supply, Installation,Testing & commisioning of 120 watts P.A Mixer Amplifier with the output power of 120 watts maximum 160watt rms at 10% Thyristor harmonic distortion(THD), 850watt RMS at 5% THD, 800 wattsRMS at 2% THD and the power supply AC voltage ranging from 220-240 volt, 50/60 hertz. with the DC input of 48 volt and 1000watts has tone controls of Bass=+- 10 db at 100 hz weighing 42kg with the speaker output of2Q,4Q.70volt&100volt has power consumption of 1600VA AC &12A DC and 100db output regulation at 1khz no load to full load ratio. The signal to noise ratio is 60db with the imnput channels of 0.8mv/4.7kq,3*Aux 100mv/50kq.The frequency response of 50-15000hz+-3db.(Make:Ahuja SSA 10000/Bosch) 183 Supply, runing, testing and commissioning of2Core x 1.5sq sqmm PVC insulated un Armoured Speaker Cable in suitable 20mm dia Pvc Rigid pipe concealed on wall and ceiling with continuous earth wire connection with painting of suitable colour. 184 Earthing 185 Earthing as per the ISI specification with an earth electrode of 2.10 metre Class B GI pipe of dia not less than 40mm withcopperearthplateofsize125mmx50mmx6mmwithnecessaryfunnellingarrangementswithnecessary masonry work and with 38mm RCC cover slab for the brick masonry 186 Supply and erection of 17.2mm, 3mtr long, Copper Bonded earth rod with backfill compound, including civil worksof base PCC for chamber andheavy duty Chambercover,, heavy duty chamber cover, etc., as per IS 3043 standards 187 Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection 188 Supply and Run of1 of No.8 SWG copper wire for earth connection 189 Supply and Run of1 of No.8 SWG copper wire in suitable PVC rigid pipeon wall / floor / ground for earth connection 190 Supply of 2mx1mRubberMatsuitablefor11KVinstallation confirming to IS(5 Nos) 191 Supply of First Aid Box complete with all First Aid Medicines 192 Supply and fixing of Shock Treatment chart with Glass frame 193 Supply and fixing of4 Nos. Fire Buckets made out of 40 x 40 x 6mm MS Angle 194 Supply and fixing of Fire Extinguishers Co2, 4.5Kg confirming to TAC norms 195 Supply and fixing of Metallic Danger Board as required by the Electrical Authorities 196 METAL SIGNAGE BOARDS: Supply and fixing of metal signages for the following:1. Mudhalvar Padaipagam text in Tamil of size 20 x 15with backlit LED placed over the base, fabricated using stainless steel sheet of minimum 16G thickness brush finish of required size and colour as required. 197 LOGO SIGNAGE BOARD 198 LOGO SIGNAGE BOARDS: Supply and fixing of acrylic signages for the following:1. Mudhalvar Padaipagam logo of size 2 x 22. CMDA logo of size 2 x 33. Directorate of Public Libraries logo of size 3 diawith backlit LED placed over the sun board base, SIDE EDGES(4): 5mm transparent white acrylic sheet with laser cut & 4inches manual raising all around with details. ACRYLIC SHEETS & ITS TECHNICAL PARAMETERS:Front: a. 5mm Imported (Mitsubishi/equivalent) acrylic cutting on laser cutting machine.b. Flexi bond make 25mm Sun board for the back of the logo.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
28.
Housing Urban and Rular Development #10191469 AOC
Furnishing Work Of Classrooms, Library And Laboratory, Equipments And Miscellaneous Work For The New University Campus Of Binod Bihari Mahato Koyalanchal University, Dhanbad- 1 Supplying Metal Exhaust Fan 300 mm Sweep-Supplying, erecting and testing of approved make 300 mm sweep Exhaust Fan heavy duty with mounting frame, blades AC 230-250 complete connection and including frame bolt/ Anchor hole fastners etc, complete finished of a as required. 2 Wall Demolition- Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. 3 Taking down chaukhats in windows including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. 4 Taking down chaukhats in doors including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. 5 Taking sown chaukhats in windows including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. 6 Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. 7 Door Frame- Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge. Profile C - Fixing with adjustable lugs with split end tail to each jamb 8 Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I. 9 Extra for providing and placing in position 2 Nos 6mm dia. M.S. barsat every third course of half brick masonry. 10 Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. 11 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 12 Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. 13 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.-Granite stone slab colour black, Cherry/Ruby red-Area of slab over 0.50 sqm 14 Sink- Supplying fitting and fixing white glazed fires clay sink of approved make with overflow arrangements supported on C.I. Or R.S. Painted bracket 40mm. Dia C.P. Brass waste with C.P. Brass chain and rubber plug 40mm dia P.V.C. Waste pipe about 750mm long with brass coupling at one endand 15mm C.I. body brass spindle bib cock of approved quality of weight not less than 450grams including cutting wall and making good the same etc. all complete as per specification and direction of E/I. Size-600 mm x 450 mm x 250 mm ) 15 FULL HEIGHT WOODEN PARTITION WITH PARTLY GLAZING- Providing and fixing partitions made of 50 mm x 50 mm pine wood / 2nd class teak wood @ 600 mm c/c both ways with the help of Fasteners/Screws etc. to achieve desired strength. Providing & fixing Comm. grade 12 mm thick commercial Pty board on the frame on both the faces i/c exposed side edges of Frame & 1.0mm thk Laminate on both outer faces and exposed side edges of ply as per the directions. Partition shall also be provided with 8 mm thick clear float glass of approved size with Polished Edges of approved brands in Wooden Partition Openings as required, fixed from all four sides from both ways inside partition openings with 10mm.tk. T.W. beadings/12 mm thick MDF Board Lipping/D-Buttons of design as per approval and direction at site. Etching / Etching Film (50 Microns) is to be provided as per approved pattern on 8 mm thick clear float glass. All wooden exposed surfaces shall be melamine polished in approved shade and texture finished as per the directions and satisfaction of Engineer In charge, compelete.This work will 16 Frosted glass sheet of nominal thickness 4 mm- Providing and pasting frosted film on glass work including all materials tools, plants and labour complete as per the directions of the Engineer-in-charge. 17 Supply & laying of PVC insulated and sheathed 1.1 kv grade twin twisted 1.5 sqmm cu flexible wire for speaker. 18 Providing & installation 1.5 Tr. 5 Star split A.C (Inverter Type) I91391-part-1 19 Copper refregerant pipe-Providing & installation Copper Tube of size 5/8 for split ac unit 1/1.5/2/3 tr capacity including nitride rubber insulation 20 Providing & installation 5 KVA wall mounted automatic voltage stablizer from range 140 V to 280V 21 Providing & installation Drain Pipe for AC 22 Non Schedule 23 * PROVIDING AND SUPPLYING MODERN DESIGN RECEPTION DESK IN ENGINEERED WOOD MAKE THE PRODUCTS UTILE AND A DELIGHT.TIMELESS DESIGN THAT ELEVATES YOUR OFFICE SPACE STRUCTURE OF SPACIOUS RECEPTION DESK,TABLETOP OFFERS YOU A GENEROUS LOOK FOR WORK SURFACE USE PREMIUM QUALITY MATERIALS OVER ALL SIZE IS 1800 MM(L)X 600 MM(D)X 750 MM(H) WHICH GIVE MORE SURFACE AREA FOR WORK ,TABLE TOP MADE OF25MM THICK ALSO TABLE TOP BASED ON SIDE PANELS MADE 18MM THICK PRELAMINATED PARTICLE BOARD OF GRADE II TYPE III OF IS 12823/LATEST. * COMBINATION CONSTRUCTION OF RECEPTION DESK ABOVE TABLE TOP 18 MM THICK COUNTER TOP TO TABLE TOP HEIGHT IS @ 300MM ,OVERALL RECEPTION DESK HEIGHT IS @ 1050MM WITH COUNTER TOP,TABLE TOP MADE 25 MM THICK PRELAM PARTICLE BOARD WORK SURFACE WITH THE EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK PVC EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE FIXED WITH HOT MELT GLUE.ALONG WITH 18MM THK ADDITIONAL MODESTY PANEL SIZE IS 1350 MM (L) X 700 MM (H) MADE BY EXCLUSIVE FROSTY WHITE COLOUR WITH EPIC DESIGN & LOOK.1 MOBILEPEDESTAL (2 DRAWERS + 1 FILING CABINET )SIZE IS 450 MM(L)X 450 MM(D)X 725 MM(H) IN PROVIDED WITH CENTRAL LOCKS FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING & PEDESTALS MOVE ON NYLON CASTORS. * THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST 24 PROVIDING AND SUPPLYING * MEDIUM BACK 360° DEGRE REVOLVING CHAIR * ALL OVER SIZE IS : 580MM(L)X 670MM(D)X1110MM(H) ,*THE CHAIR MADE OF FULL UPHOLSTERY IN BLACK COLOUR .IT WILL COMES IN MATTE FINSIH IN CONTEMPORARY STYLE .DETAILS :* ARMS : AMREST IS HAVING TWO ADJUSTMENT HEIGHTS (UP & DOWN) .* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) .* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT* MECHANISM : SINGLE LOCKING MECHANISM. SEAT MAXIMUM HEIGHT IS 580MM & MINIMUM HEIGHT IS 480MM & BACK HEIGHT FROM FLOOR MAXIMUM HEIGHT IS 1110MM & MINIMUM HEIGHT IS1010MM* GAS LIFT 100 MM TELESCOPIC HAUDRAULIC * BASE : 650MM NYLON BASE WITH SMOOTH CASTORS . 25 PROVIDING AND SUPPLYING 3 Seater Public Place Seating Chair of mildsteel with arm and backrest WITHOUT CUSHION,THREE SEATERTYPE WAITING AREA CHAIR - MATERIAL : STAINLESS STEEL SIZE 1820MM(L)X 690MM(D)X 790MM(H) COLOUR : SILVER/WEIGTH OF PRODUCT : 34 KG APPROX,* SUPPLYING AND PLACING IN POSITION OF A STAINLESS STEEL VISITOR BENCH OF SIZE IS 1820MM(L)X 690MM(D)X 790MM(H). THE COMPLETE STAINLESS STEEL BENCH HAS SEAT & BACK SINGLE SECTION. PER SEAT LENGTH IS @ 520 MM &SEATING HEIGHT IS @ 430 MM FROM GROUND . OWING TO THE SMOOTH FINISH, DURABILITY AND TENSILE STRENGTH BEAM STAINLESS STEEL MADE BY 1.6MM THICK.SEAT IS MADE BY 1.2MM THICK STAINLESS STEEL BORDER WITH CHROME PLATING FOR EVERY SEAT & BACK ; STAINLESS STEEL HANDLES CHROME PLATED & DIE PRESSED LEGS AT THE END OF CHAIRS.GROSS WEIGHT OF REGULAR 3-SEATER WILL BE 34 KG.THE STEEL GRADE 202 HIGH YIELD STRENGTH AS PER IS:513 & IS:304 GRADE. 26 Supplying of Portrait/Landscape Not applicable Fabric Pin Up Notice Boards(Fabric Pin Up Notice Boards 3 X 6 FT GREEN),Specification-Width of Board in mm:900 mm,Colour(Front/ Display layer):Green,Height of Board in mm:1800mm,Rear panel material of Board:Laminated sheet,Overall pinability depth ofBoard in mm:9 millimeter,Core material thickness inmm:9 millimeter 27 PROVIDING AND SUPPLYING COLLEGE DESK TOMKINS MATERIAL : PRELAMINATED PARTICLE BOARD WITH M.S BASE UNIT SIZE : 590 MM(L) X 1090 MM(D) X 830 MM(H) PER SEAT SIZE- 590 MM X 375 MM X 450 MM/ONE SEATER DESK SIZE :1090 MM(L) X830 MM(H) COLOUR : AVAILABLE ON REQUEST/FINISH : EPOXY POLYESTER ,* PROVIDING & SUPPLYING TWO SEATER COLLEGE DESK TOMKINS COMBINATION OF THREE ROWS FIRST , MIDDLE AND LAST SCRATCHPROOF EASY WIPE TOP / DURABLE ,STRONG & SAFE,UNDERSTRACTURE MADE OF MAIN FRAME MDE OF CRCA POWDER COATED IS GRAD:304 M.S BLACK POWDER COATED TO THE THICKNESS 50-60 MICRONS(+/-5 MICRON) EPOXY POLYESTER COATING.* TABLE TOP & MODESTY PANNEL MADE IN 18MM THICK PRELAMINATED PARTICAL BOARD OF GRADE II TYPE III OF IS 12823/LATEST WITH MACHINE PRESSED EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE FIXEDDULY PASTED WITH THE ASSISTANCE OF EDGE BANDING MACHINE AT 200 DEGREE CELSIUS.CHAIR WITH GAS LIFT ,A). BACK FRAME: 1.2MM COLD ROLLED STEEL/B). BACK BOARD: 10MM PLYWOOD, NO CUSHION C). SEAT BOARD: 15MM PLYWOOD, NO CUSHION/D). TIP-UP SYSTEM: SPRING MECHANISM E). 2. LEG: COLD-ROLLED STEEL, FIXING ON THE FLOOR BY SCREWS, 80 X 35 X 1.5MM THICK OVAL TUBE, BLACK POWDER SPRAYING.* THREE LAYER PRELAMINATED PARTICLES BOARD ( WOOD PRODUCT ) OF GRADE II TYPE III OF IS 12823/LATEST 28 Supplying of Material & Subtype Engineered Wood Table Top Material Engineered Wood Finish Matte Colour & Colour Family Brown - Classic Walnut Dimension (W)550mm X (D)550mm X (H)1200mm Size Compact Assembly Type Knock Down (Obelisk), 29 Suppling of Writing Board ( 4x10 Non-Magnetic) of material Top Surface materials (Used for white boardsurface)-Porcelain,Top surface material thickness -0.7 mm to 0.8 mm,Frame material -Anodized extruded aluminum alloy hollow section conforming to IS 733 (With latest amendment),Frame wall thickness-1.2 mm,Frame section front -20 mm,Frame section side -16 mm,Core material-MDF board grade-I conforming to IS 12406 (with latest amendment),Core material thickness -9 mm as per Department incharge 30 Supplying of 14 SEATER U -* PROVIDING & SUPPLYING U - SHAPE MODERN DESIGN CONFERENCE TABLE & IN BETWEEN U SHAPE TABLE TOP LENGTH IS @ 8850 MM, TABLETOP OFFERS YOU A GENEROUS WORKSPACE,DESK PRIMARY WORK SURFACE USE PREMIUM QUALITY MATERIALS OVER ALL SIZE IS 8850 MM(L)X 600MM(D)X 750MM(H) TABLE TOP MADE OF 36MM THICK WHICH GIVE MORE SURFACE AREA FOR WORK ,MACHINE MADE MODULAR FURNITURE MADE PRELAMINATED PARTICLE BOARD OF GRADE II TYPE III OF IS 12823/LATEST, * CONSTRUCTION PROVISION OF CONFERENCE TABLETOP SUPPORTED WITH 18MM THICK SIDE PANNELS IN BROWN-BLACK OAK COLOUR MADE BY PRELAMINATED PARTICLE BOARD AND BELOW THE TOP 18MM THICK PRELAM PARTICLE BOARD MODESTY PANEL.OUR WORK SURFACE FURNITURE IS FINISHED WITH EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE,FIXED WITH HOT MELT GLUE. * THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST, 31 Supplying of * HIGH BACK 360° DEGRE REVOLVING CHAIR SKU : MARVEL/HB/ECO ,* ALL OVER SIZE IS : 595MM(L)X 670MM(D)X1380MM(H) ,*THE CHAIR MADE OF FULL MESH IN BLACK COLOUR .IT WILL COMES IN MATTE FINSIH ABOUT STYLE TYPE IS MODREN.DETAILS :* * ARMS : FIXED PP ARMSREST .* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT).* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK :FRAME OF DESIGN SHALLBE CURVEDMADE OF TWO PIECES INJECTION MOULDED FRAME COVER WITH MESH .BACKREST SUPPORTADJUSTABLE LUMBAR SUPPORT* MECHANISM : SINGLE LOCKING MECHANISM . * ONLY SEAT SIZE IS 670MM(L)X 595MM(D)X470-570MM(H) , SEAT MAXIMUM HEIGHT IS 570MM & MINIMUM HEIGHT IS 470MM & BACK MAX HEIGHT IS @ 1380MM .* GAS LIFT 100 MM TELESCOPIC HAUDRAULIC * BASE : NYLON BASE IS 620MM PITCH CENTER DIA (660MM WITH CASTORS) . 32 Supplying ofMEDIUM BACK 360° DEGRE REVOLVING CHAIR * ALL OVER SIZE IS : 595MM(L)X 670MM(D)X1125MM(H) ,*THE CHAIR MADE OF FULL MESH IN BLACK COLOUR .IT WILL COMES IN MATTE FINSIH ABOUT STYLE TYPE IS MODREN.DETAILS :* * ARMS : FIXED PP ARMSREST .* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT).* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK :FRAME OF DESIGN SHALLBE CURVEDMADE OF TWO PIECES INJECTION MOULDED FRAME COVER WITH MESH .BACKREST SUPPORTADJUSTABLE LUMBAR SUPPORT* MECHANISM : SINGLE LOCKING MECHANISM .* ONLY SEAT SIZE IS 670MM(L)X 595MM(D)X470-570MM(H) ,SEAT MAXIMUM HEIGHT IS 570MM & MINIMUM HEIGHT IS 470MM & BACK MAX HEIGHT IS @ 1125MM .* GAS LIFT 100 MM TELESCOPIC HAUDRAULIC * BASE : NYLON BASE IS 620MM PITCH CENTER DIA (660MM WITH CASTORS) . 33 Supplying of Tte Mild Steel Pipe of diameter 19 mm and wall thickness 16gauge. Classroom Chairs, tte,Thickness-2mm to 45mm,Material-Mild Steel Weight-Depends upon the size,Outside Diameter-0.80 Inch to 36 Inch 34 Supplying of 1-Bay Sprocket Chain Drive Mechanism MobileStorage Compactors,Material-Mild Steel Product Type-1 Bay,Height -7 ft,Storage Capacity-50-80 kg Usage/Application office, Home, Hospital, Store Room, Warehouse 35 Supplying of -- Movable File StorageSystem (Compactor) 1-Bay Mechnized Drive Type(COMPACTOR 2 ( 04 BODY)) 36 Supplying of Methodex MS1-6MCMETHODEX(Methodex MS1-6MC),Accutec Mobile Storage System,Material SS,Usage/Application-Warehouse Height-8-10 Feet,No of Layers-5 37 Supplying of : METAL STORAGE OF SIZE 900MM(L)X 450MM(D)X 1980MM(H) BODY MADE OUT IN 22 GAGUE(0.8MM) & DOOR 19 GAGUE(1 MM) CRCA SHEET. 4 ADJUSTABLE SHELVE IN 22 GAGUE(0.8MM) & PEDESTAL 18 GAGUE 1.2 MM CRCA SHEET. HAVING FOUR SHELVES MAKING FIVE COMPARTMENT, UNIFORMLY DISTRIBUTED LOAD CAPACITY OF EACH SHELF SHALL BE 60 KG MAXIMUM,FITTED WITH MS BODY LOCK & HANDLE. FINISHING WITH EPOXY POLYESTER POWDER COATED TO THE THICKNESS 50-60 MICRONS(+/-5 MICRON)IN COLOR GREY-LIGHT GREY. 38 Supplying of : PREMIUM SUITESDIRECTOR TABLE STRUCTURE OF L-SHAPED DESK . PRIMARY WORK SURFACE OVER ALL SIZE IS 2400MM(L)X 2330MM(D)X 770MM(H) 45MM THICK TABLE TOP MADE OF PRELAMINATED PARTICLE BOARD WORK SURFACE WITH RICH CHERRY FINISH SAME MATCHING EDGE BANDING MADE OF SAME RED CHERRY P.U POLISH.MODESTY IS DESIGNED WITH LEATHER PATCH.SIDE PANNEL IS MADE OF 36MM THICK . * PROVISION OF SIDE UNIT OF SIZE IS 1200MM(L)X 595MM(D)X 770MM(H) ,(COMBINATION CONSTRUCTION ON TABLE TOP WIRE MANAGEMENT 2 HOLE WITH SS GROOMENT & 1 HOLE WITH PVC GROOMENT ON TOP SIDE UNIT. BELOW TABLE TOP ONE KEYBOARD TRAY,IN SIDE UNIT BELOW THE TOP 1 KEY BOARD TRAY,1 OPEN BOX FILE ,1 DRAWER + 1 OPEANABLE DOOR SHELVE. * FIXED PEDESTAL OF SIZE450MM(L)X 400MM(D)X 690MM(H) , HAVING 3 EQUAL DRAWERS IN PROVIDED WITH CETNRAL LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING. OVERALL CONSTRUCTION OF PEDESTAL IS 18 MM ALONG WITH FECIA OF DRAWERS. * ALL THE MDF BORAD ARE IS-14587-1998 WITH CONFIRM TO DIN 68861.ISO 9001- 2015 QUALITY CERTIFICATION CONFIRMING TO ASTM D 4499 STANDARDS FOR VISCOSITY AND THERMAL STABILITY . 39 Supplying of* HIGH BACK 360° DEGRE REVOLVING CHAIR * ALL OVER SIZE IS : 590MM(L)X 505MM(D)X1280MM(H) , *THE CHAIR MADE OF FULL LEATHERETTE IN BLACK COLOUR . IT WILL COMES IN MATTE BLACK FINISH FINSIH IN CONTEMPORARY STYLE . DETAILS :* ARMS :CHROMEFINISH ARMS WITH PU PADDING . * USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) . * SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT * MECHANISM : KNEE TILT MECHANISM . * ONLY SEAT SIZE IS 505MM(L)X 505MM(D)X610MM(H) & THE BACK SIZE IS 590MM(L)X 710MM(H) SEAT MAXIMUM HEIGHT IS 610MM & MINIMUM HEIGHT IS 510MM & BACK HEIGHT FROM FLOOR MAXIMUM HEIGHT IS 1280MM & MINIMUM HEIGHT IS1180MM * GAS LIFT 100 MM TELESCOPIC HAUDRAULIC * BASE : 650 MM CHROME BASE WITH SMOOTH CASTORS . 40 Supplying of* FIX CANTILEVER CHAIR * ALL OVER SIZE IS : 570MM(L)X 500MM(D)X940MM(H) , *THE CHAIR MADE OF FULL LEATHERETTE IN BLACK COLOUR . IT WILL COMES IN MATTE FINSIH IN CONTEMPORARY STYLE . DETAILS : * ARMS : PADDED ARMREST. * USE OF PLY: SEAT & BACK PLYWOOD MADE OF 12 MM HOT PRESSED. * SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT * ONLY SEAT SIZE IS 570MM(L)X 500MM(D)X475MM(H) SEAT HEIGHT IS @ 940MM & BACK HEIGHT IS @ 475MM . * FIXED CANTILEVER CHAIR . * BASE : CHROME FINISH TUBLAR FRAME OF CANTILEVER TYPE . 41 * SUPPLYING AND PLACING FIVE SEATER (3+1+1) EXCLUSIVE PREMIUM LEATHERETTE MODERNIST CLASSIC DESIGN LOUNGE SEATING SOFA SIZE IS 3 SEATER- 1905MM(L) X890MM(D)X 870MM(H)SOFA SIZE IS 1 SEATER -(W)960mm X (D)890mm X (H)870mm ,WITH KILN-DRIED WOOD FRAMING MAKES IT WARP AND SCRATCH RESISTANT,COMFORTABLE SEAT DEPTH & HEIGHT DESIGNED KEEPING MODERN INDIAN LIFESTYLE IN MIND,WRAPPED IN BUTTERY-SOFT PREMIUM LEATHERETTE, THE PANELLED BACK AND CUSHIONED ARMRESTS ENCOURAGE LOUNGING,DESIGNED WITH MODERNITY & ELEGANCE, CHOOSE THE OPTION THAT SUITS YOUR HOME. * COMBINATION CONSTRUCTION STRUCTURE ARE MADE INMOISTURE CONTENT SHALL BE LESS THAN (10-12)%. THICKNESS OF PLYWOOD USED (MM) SHALL BE 12 MM GRADE IS 303 INDIAN STANDARD FOR COMMERCIAL (COMMON) AND MOISTURE PROOF PLYWOOD (TENTATIVE).UNDERSTRUCTURE FRAME SHALL BE CONSTRUCTED FROM 18 MM THICK KILN-DRIED GERMAN BEECH WOOD FRAMING IS HIGHLY DURABLE. THE COMPLETE STRUCTURE SHALL BE COVERED BY P.U.FOAM FIXED WITH ADHESIVE GLUE ,THE FRAME SHALL BE PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING 28 +/- 5 DENSITY IN SEAT IT SHALL BE STACK FOAM OF 50MM THIK,40MM THICK BACK FOAM HAVING 20 +/- 5 DENSITY FOAM USED ,THERE SHALL BE CUSHION ARM 40MM THICK PROVIDED PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING DENSITY 20 +/- 5. THE COMPLETE STACK FOAM STRUCTURE SHALL BE COVERED WITH PREMIUM LEATHERETTE IN BLACK-EERIE BLACK-COFFEE BROWN,BROWN-BURNT UMBER COLOUR, IT COMPLEMENTS THE MODISH LEGS ARE MADE BY ROUND SHAPE IN PVC MATERIAL. 42 Supplying of Material & Subtype Solid Wood - Beech Wood Table Top Material Clear Glass,Frame Material Solid Wood Leg Material Solid Wood,Finish Matte Colour & Colour Family Brown - Walnut,Dimension (W)1130mm X (D)630mm X (H)410mm,Number Of Recliners 1 Number Of Reclining Positions 3,Size Standard (HOPPER/CT), 43 Supplying of6 SEATER Rectangular MEETING TABLE DURIAN MODEL SMART/CON/6FT MADE OF PRELAMINATED PARTICLE BOARD WITHSLANTLEGS50X50 MM MS UNDERSTRUCTURE IN POWDER COATING 2TOP MADE OF25MMTHICK PRELAMINATED PARTICLE BOARD IN FROSTY WHITE COLOR WITH MAIN TABLE SIZE1800MM(L)X 1050MM(D)X 750MM(H) (SMART/CON/6FT/A), 44 SUPPLYING & PROVIDING CAFETERIA CHAIR SIZE IS 381MM(L)X 419MM(D)X839MM(H) A COMBINATION OF SYNTHETIC FIBER WITH STAINLESS STEEL MAKE THE PRODUCTS UTILE AND A DELIGHT, THE COMPLETE STRUCTURE SHALL BE MADE UP OF 20% GLASS FILLED BLOW MOLDED HIGH-DENSITY POLYETHYLENE ANDIS,THE FRAME STRUCTURE SHALL BE SUPPORTED BY ( 2 STRAIGHT + 2 SLANT ) FOUR LEGS.THE TUBULAR WELDED FRAME IS MADE FROM DIA2.22 +/- 0.03CMX 0.12+/- 0.0128 CM AND 3.5+/- 0.03 CM X 0.12+/- 0.0128 AM STAINLESS STEEL 202 GRADE TUBE & THE TUBE ARE BUFF POLISHED TO GIVE SHINY FINISH.SEAT AND IN BACK GIVEN HANDLE TO HOLDARE MADE OF INJECTION MOULDED HIGH IMPACT STRENGTH POLYPROPYLENE POLYMER COMPOUND WITH INDOOR GRADE UV RESISTANCE AND PRESSED FITTED WITH LEGS.THE CHAIR IS EASY TO STORE WHEN NOT IN USE, SINCE YOU CAN STACK UP TO 6 CHAIRS ON TOP OF EACH OTHER. (COCO/SUR). 45 SUPPLING OF METAL STORAGE OF SIZE 900MM(L)X 450MM(D)X 1830MM(H) BODY MADE OUT IN 22 GAGUE(0.8MM) & DOOR 19 GAGUE(1 MM) CRCA SHEET. 4 ADJUSTABLE SHELVE IN 22 GAGUE(0.8MM) & PEDESTAL 18 GAGUE 1.2 MM CRCA SHEET.HAVING FOUR SHELVES MAKING FIVE COMPARTMENT, FITTED WITH MS BODY LOCK & HANDLE. WITH 2 NUMBERS OF GLASS DOOR SHUTTERS , THE GLASS USED SHALL BE 4MM THICK CLEAR. UNIFORMLY DISTRIBUTED LOAD CAPACITY OF EACH SHELF SHALL BE 30 KG MAXIMUM.EACHRACKSHALLBEPROVIDEDWITHSTIFFENERATBOTTOMFOR STRENGTH.THE ENTIREBODYPANELAND SHELF SHALLBEMADEOF HIGHYIELD STRENGTH,THE COMPLETE STEEL STRUCTURE SHALL BE CONSTRUCTED BY WELDING AND PROVIDE FINISHING WITH EPOXY POLYESTER POWDER COATED TO THE THICKNESS 50-60 MICRONS(+/-5 MICRON)IN COLOR GREY-LIGHT GREY 46 SUPPLING OF DIRECTOR DESKDIRECTOR TABLE STRUCTURE OF L SHAPED DESK .PRIMARY WORK SURFACE OVER ALL SIZE IS 1500MM(L)X 750MM(D)X 750MM(H) 36MM THICK TABLE TOP MADE OF PRELAMINATED PARTICLE BOARD WORK SURFACE WITHWENGE FINISH, USING HOT MELT GLUE TO FIXING 2MM THICK PVC EDGE BANDING MADE OF SAME MATTE FINISH. SIDE PANNEL IS MADE OF 25MM THICK.*PROVISION OF SIDE RUNNER OF SIZE IS 750MM(L)X 450MM(D)X 760MM(H) ,( CONSTRUCTION IS FROM RIGHT SIDE OF SIDE UNIT TOP BASED ON FIXED PEDESTAL WITH SS STUD OF GRADE 304, ON TABLE TOP PVC GROMENT HOLEFOR WIRE MANAGEMENT .*FIXED PEDESTAL OF SIZE450MM(L)X 450MM(D)X 650MM(H) PER DRAWER HEIGHT IS @ 136MM, FILLING DRAWER HEIGHT IS @ 300MM HAVING (2 EQUAL DRAWERS + 1 FILLING DRAWER) IN PROVIDED WITH CETNRAL LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING.OVERALL CONSTRUCTION OF PEDESTAL IS 18 MM ALONG WITH FECIA OF DRAWERS. *THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST , 47 SUPPLING OF* CANTILEVER CHAIR SKU : 70011/CN/A, * ALL OVER SIZE IS : 590MM(L)X 490MM(D)X980MM(H) , *THE CHAIR MADE OF FULL FABRIC INBLACK COLOUR . IT WILL COMES INFINSIH IN CONTEMPORARY STYLE . DETAILS :* ARMS : FIXED ARMS P.P. CONNECTED WITH SEAT AND BACK .* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) .* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32(±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT* BASE : M.S POWDER COATED TUBLAR FRAME OF CATILEVER TYPE . THE SELLER / COMPANY SHOULD BE ISO 9001:2015, ISO 50001:2018, ISO 14001:2015, ISO 45001:2018 CERTIFICATES OF THE MANUFACTURER CERTIFIED BY NATIONAL ACCREDITATION BOARD OF CERTIFYING BODIES, IGBC, SEDEX, GREEN PRO, AIOTA, INDIAN DESIGN MARK, FSC CERTIFICATE. 48 SUPPLING OF OFFICE DESKDESK STRUCTURE OF L SHAPED DESK . PRIMARY WORK SURFACE OVER ALL SIZE IS 1500MM(L)X 600MM(D)X 750MM(H) 25MM THICK TABLE TOP MADE OF PRELAMINATED PARTICLE BOARD WORK SURFACE WITH THE EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE WITH THE HOT MELT GLUE . MODESTY PANNEL 18MADE OF MM THICK . *PROVISION OF SIDE UNIT OF SIZE IS 900MM(L)X 450MM(D)X 750MM(H) ,(COMBINATION CONSTRUCTION WIRE MANAGEMENT HOLE WITH PVC GROOMENT ON TABLE TOP, LEFT SIDE TABLE TOP BASED ON A 18MM THICK SIDE PANNEL ENGINEERED WOOD & FROM RIGHT SIDE UNIT HAVE 2 SLIDING DOOR + 1 FIXED SHELVE . *SIDE UNIT SIZE900MM(L)X 450MM(D)X 750MM(H), IN PROVIDED WITH LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING. OVERALL CONSTRUCTION OF SIDE UNIT IS 18MM THICK ALONG WITH FECIA OF SLIDDING SHUTTERS. *THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST . 49 SUPPLING OF * FIX CANTILEVER ,* ALL OVER SIZE IS : 595MM(L)X 510MM(D)X875MM(H) ,*THE CHAIR MADE OF FULL LEATHERETTE IN BLACK COLOUR .IT WILL COMES IN MATTE FINSIH IN CONTEMPORARY STYLE .DETAILS :* ARMS : PADDED ARMREST.* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) .* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT* ONLY SEAT SIZE IS 500MM(L)X 510MM(D)X455 MM(H) & THE BACK SIZE IS 440MM(L)X 595MM(H) , BACK HEIGHT IS @ 440MM .* BASE : 4 LEGS METAL POWDER COATED* THE SELLER / COMPANY SHOULD BE ISO 9001:2015, ISO 50001:2018, ISO 14001:2015, ISO 45001:2018 CERTIFICATES OF THE MANUFACTURER CERTIFIED BY NATIONAL ACCREDITATION BOARD OF CERTIFYING BODIES, IGBC, SEDEX, GREEN PRO, AIOTA, INDIAN DESIGN MARK, FSC CERTIFICATE. THE BIDDER SHOULD BE A MEMBER OF BIFMA AND AT LEAST TWO PRODUCTS OF THE OEM SHOULD BE CERTIFIED AS BIFMA COMPLIANT AND AN OFFICIAL PRODUCT OFFICIAL LINK/SCREENSHOT OF THE PRODUCT LISTING MUST BE PROVIDED FROM WWW.BIFMA.ORG WARRANTY-5 YEARS MAKE-DURIAN /GODREJ/FEATHERLITE 50 * PROVIDING AND SUPPLYING PENTA WORKSTATIONLSHAPE SINGLE SEATER UNIT NON SHARING IN COMPLETELY KNOCK DOWN CONDITIONS WITH AN OVERALL SIZE 1500MM(L)X 600MM(D)X 1200MM(H) THAT IS TO BE ASSEMBLED AT SITE. THE WORKTOPSHALLHAVETHESIZE1490MM-1490MM (L) x 592(D) MADEUPOF25MMTHICKPRE- LAMINATED PARTICLE BOARD OF GRADE II TYPE III OF IS 12823/LATEST . OF IS LEVEL WITH APPROVED LAMINATE AND FINISH AS PER APPROVED SHADE. * THE PROFILE OF THE TOP SHALL BE IN RECTANGLE SHAPE AND THE EDGES SHALL BE SEALEDWITH 2MM THICK THIN STRIP OF IMPERMEABLEPVCTHAT IS CUT TO FIT THE SIZE OF BOARD PANEL AND DULY PASTED WITH THE ASSISTANCE OF EDGE BANDING MACHINE AT 200 DEGREE CELSIUS. * THE TOP TRIM, TOP BAR, MID BAR, VERTICAL BAR, RACEWAY, SKIRTING SHALL BE MADE UP OF ALUMINIUM EXTRUSIONS (PRE-TREATED)AND DULY POWDER COATED WITH POLYESTER POWDER COATING 40P-60PTHICK . THE TRIMS SHALL HAVE THE SIZE 67MM X 19MM WITH 1.5MMTHICKCOVERED WITH DIE CAST END CAPS ON JOINTS 2 WAYS,3 WAYS& 4 WAYS(L-COVERFORCORNER,T-COVERFORMIDDLESECTIONWHEREVER REQUIRED).THEALUMINIUMRACEWAYSHALLBESITUATEDBELOWTHEWORKTOPWITHAN OVERALLSIZE149MM(H)X60MM(D)WITH1.4MMCOVERTHICKNESSAND2MMBACK THICKNESS AS PER REQUIREMENT OF INLAYING THE ELECTRICAL MANAGEMENT AND CARRYING THE WIRE HORIZONTALLY. *THE EXPOSED VERTICAL AND HORIZONTALFACES OF THE FRAMES SHALL BE SNAPFITTEDWITHTRIMS.THERESHALLBESOFT-BOARD(WITHFABRIC)ANDMARKERBOARD PROVIDED AT FRONT OF THE USER. LAMINATED TOP TILE AND BOTTOM TILE SHALL BE SITUATED AT BOTH SIDES OF THE USER AND BELOW THE WORK TOP RESPECTIVELY. THE PARTITION SHALL HAVE CONCEALED WIRE MANAGEMENT CAPABILITIES AND SHOULD BE ENGAGED FOR RESPONSIVE AND SAFE OPERATIONSOF POWER,TELECOMMUNICATIONSANDDATA(LAN)AND HASSEPARATE COMPONENTS FOR ELECTRICAL, DATA AND TELEPHONE CABLES HAVING ADEQUATE CAPABILITY OF BOTH THE VERTICAL AND HORIZONTAL WIRE MOVEMENTS.SLOTS/CUT-OUTS SHOULD BE GIVEN ON RACEWAYSTOFIXALLELECTRICALANDDATAPOINTS.SINGLESIDEDPVCWIRE MANAGER SHOULDBE ENCLOSEDATTABLETOP.ADJUSTABLE LEVELLERSHOE SHALL BE PROVIDED AT BOTTOM OF THE PARTITION TO AVOID SCRATCHESON THE FLOOR.PARTICLE BOARD OF GRADE II OFISLEVEL. * THREE LAYER PRELAMINATED PARTICLES BOARD (WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST .* THE SELLER / COMPANY SHOULD BE ISO 9001:2015, ISO 50001:2018, ISO 14001:2015, ISO 45001:2018 CERTIFICATES OF THE MANUFACTURER CERTIFIED BY NATIONAL ACCREDITATION BOARD OF CERTIFYING BODIES, IGBC, SEDEX, GREEN PRO, AIOTA, INDIAN DESIGN MARK, FSC CERTIFICATE. THE BIDDER SHOULD BE A MEMBER OF BIFMA AND AT LEAST TWO PRODUCTS OF THE OEM SHOULD BE CERTIFIED AS BIFMA COMPLIANT AND AN OFFICIAL PRODUCT OFFICIAL LINK/SCREENSHOT OF THE PRODUCT LISTING MUST BE PROVIDED FROM WWW.BIFMA.ORG WARRANTY-5 YEARS MAKE-DURIAN /GODREJ/FEATHERLITE 51 PROVIDING & SUPPLYINGFIXING OF TWO SEATER SCHOOL DESK WITH SHELF/STORAGE UNDER DESK WHICH ONE MADE BY CAST IRON,DESK TOP MADE BY 18MM THICK PRELAMINATED PARTICAL BOARD OF GRADE II TYPE III OF IS 12823/LATEST,TWO SEATER CLASSROOM DESK CUM BENCH, TOTAL SIZE OF BENCH : 1050MM(L)X 950MM(D)X 760MM(H) DESK SIZE : 1050MM (W) X 400MM (D) X 760MM (H) BENCH SIZE : 1050MM (W) X 310MM (D) X 390 / 760MM (H) BACK SIZE : 1050MM (W) X 150 MM (H),TABLE TOP SHALL BE POLYPROPYLENE CO POLYMER (PPCP).BANDING UNDER STRUCTURE-BLACK 9005 ERW PIPE (AS PER IS:7138) : 25X25X1.2MM SQUARE MS PIPE, OF THICKNESS 1.2MM IN BLACK EPOXY POLYESTER POWDER COATED TO THE THICKNESS 50-60 MICRONS(+/-5 MICRON) AT BASE WITH PLASTIC CAPS MADE OF PP COPOLYMER (3530 GRADE) ARE ALSO PROVIDED ON THE REAR FRAMES ADDING MORE AESTHETIC VALUE TO THE PRODUCT. * ADDITIONAL HORIZONTAL SUPPORTS OF M.S. C SECTIONS OF 1.5MM THICK ARE PROVIDED BELOW THE DESK & SEAT.SHELF: 0.8MM THICK POWDER COATED M.S. SHEET BELOW THE DESK & HOOKS ON EITHER SIDE OF DESK IN M.S. ROD OF DIA 6MM.TOP,SEAT AND BACK PANEL: 18MM THICK PRE LAMINATED BOARD WITH MACHINE PRESSED EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE FIXEDDULY PASTED WITH THE ASSISTANCE OF EDGE BANDING MACHINE AT 200 DEGREE CELSIUS. * THREE LAYER PRELAMINATED PARTICLES BOARD ( WOOD PRODUCT ) OF GRADE II TYPE III OF IS 12823/LATEST.* 52 Suplying of Laboratory Steel Furniture Sidebench with rack and table top of specification,Size of side benches/Island benches (LxWxH):1800 mm X 1800 mm X 900 mm,Type of Frame for installation of bench:C type frame,C Type Fixed Under Bench Cabinet size:500 mm x 500 mm x 540 mm (having one door, one drawer and one adjustable/removable shelf) 53 Supplying of Laboratory Steel Furniture Island bench with table top Size of side benches/Island benches (LxWxH):900 mm X 1500 mm X 900 mm,Type of Frame for installation of bench:C type frame,C Type Fixed Under Bench Cabinet size:500 mm x 500 mm x 540 mm (having one door, one drawer and one adjustable/removable shelf) 54 Supplying ofPowder coated Round Classroom Stools Load of 50 Kg of stool of specification:Height Adjustment: Without Hydraulic,Frame and support made of CHROME PLATED MS TUBES,Chair Type:Non Revolving,Type of seating:Only seat,Pedestal base :Aluminium Die Cast 55 Suppling of Over Head Storage delite hi-tech of specification Material of Construction:ISI Marked, three layer Prelaminated particle Board conforming to Grade II Type III of IS 12823/2013 laminated with 0.6-0.8 mm thick lamination conforming to IS 2046/1995 and balancing lamination of 0.5 mm thick on the back side,Number of Shelves (Nos):2 Number of Doors (Nos) -2 ,Height in mm (±10 mm)-750,Depth in mm (±5 mm)-450 56 Suppling ofStainless Steel Name Plates, Monograms, Labels, As per BHEL ,Specifications :Stainless Steel Name Plates, Monograms, Labels, 57 Suppling of Aquaguard RO & UV both SS304 Drinking Water Coolers With Built In Water Purifiction System AquaguardR 58 Suppling ofStainless Steel External Branding Signage Boards, Size 22X6 Feet,Signage Printing-Single size vinyl print ,Material -Stainless steel ,Coating: Gloss or matte,Fabrication Specs-framing with one coat of red oxide & 2 coats of oil paint to avoid rusting 59 PROVIDING & SUPPLYING DIRECTOR DESKDIRECTOR TABLE STRUCTURE OF L SHAPED DESK .PRIMARY WORK SURFACE OVER ALL SIZE IS 2100MM(L)X 900MM(D)X 750MM(H) 50MM THICK TABLE TOP MADE OF PRELAMINATED PARTICLE BOARD WORK SURFACE WITH CLASSIC WENGE BROWN FINISH 2MM THICK PVC EDGE BANDING MADE OF SAME MATTE FINISH. SIDE PANNEL IS MADE OF 50MM THICK* PROVISION OF SIDE RUNNER OF SIZE IS 1200MM(L)X 400MM(D)X 760MM(H) ,(CCOMBINATION ONSTRUCTION BELOW TABLE TOP 1 KEY BOARD TRAY IN PVC WITH TELESCOPIC CHANNEL ON RIGHT SIDE IS MOVABLESIDE RUNNERHAVING 1 OPENABLE DOOR WITH 1 FIXED SHELVE, 1 OPEN BOX WITH 1 FIXED SHELVE UPPER SHELVE HEIGHT IS @ 320MM BELOW SHELVE HEIGHT IS @324@ + 3 DRAWERS (2 EQUAL DRAWERS + 1 FILLING DRAWER)PER DRAWER HEIGHT IS @ 184MM, FILLING DRAWER HEIGHT IS @ 303MM HAVE CENTRAL LOCKAND HANDLES WITH CASTORS .* MOBILE PEDESTAL OF SIZE400MM(L)X 530MM(D)X 671MM(H) ,PER DRAWER HEIGHT IS @ 186MM, FILLING DRAWER HEIGHT IS @ 195MM HAVING (2 EQUAL DRAWERS + 1 FILLING DRAWER) IN PROVIDED WITH CETNRAL LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING.OVERALL CONSTRUCTION OF PEDESTAL IS 18 MM ALONG WITH FECIA OF DRAWERS. * THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST , 60 PROVIDING & SUPPLYING* FIX CANTILEVER CHAIR * ALL OVER SIZE IS : 610MM(L)X 505MM(D)X990MM(H) , *THE CHAIR MADE OF FULL LEATHERETTE IN BLACK COLOUR . IT WILL COMES IN MATTE BLACK FINISH FINSIH IN CONTEMPORARY STYLE .DETAILS :* ARMS :CHROMEFINISH ARMS WITH PU PADDING .* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) . * SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORTbackrest support* ONLY SEAT SIZE IS 610MM(L)X 505MM(D)X485MM(H) & THE BACK SIZE IS 610MM(L)X 540MM(H) ,* BASE : CHROME FINISH TUBLAR FRAME OF CANTILEVER TYPE . 61 PROVIDING & SUPPLYING OFFICE DESK STRUCTURE OF RECTANGULAR SHAPE .PRIMARY WORK SURFACE OVER ALL SIZE IS 1200MM(L)X 600MM(D)X 750MM(H) 25MM THICK TABLE TOP MADE OF 25MM THICK PRELAMINATED PARTICLE BOARD WORK SURFACE WITH THE EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE WITH THE HOT MELT GLUE . MODESTY PANNEL MADE OF 18MM THICK, WIRE MANAGEMENT HOLE WITH PVC GROOMENT ON TABLE TOP.*CONSTRUCTION RIGHT SIDE OF TABLE TOP IS BASED ON A FIXED PEDESTAL3 DRAWERS & FROM LEFT SIDE OF TABLE TOP IS BASED ON 18MM THK ENGINEERED WOOD PVC EDGE BANDING PEDESTAL BACK,TOP,BOTTOM & DRAWERS ARE MADE OF 18MM THICK WITH 1 CPU TROLLY MADE IN BLACK METAL POWDER COATED.*FIXED PEDESTAL:L:410MM(L)X 580MM(D)X 750MM(H) ,IN PROVIDED WITH CETNRAL LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING. OVERALL CONSTRUCTION OF PEDESTAL IS 18 MM ALONG WITH FECIA OF DRAWERS. *THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823. 62 Suppling of Material & Subtype Solid Wood - Beech Wood Table Top Material Solid Wood,Leg Material Solid Wood Finish Glossy Colour & Colour Family Brown - Walnut Dimension (W)680mm X (D)530mm X (H)450mm Table Top Thickness 8mm,Size Compact, 63 PROVIDING & SUPPLYING ANGLE RACKOF SIZE 838MM(L)X 305MM(D)X 1676MM(H) STEEL BOOKCASE HAVING 4 DOORS AND K. TYPE OF LOCK: THREE WAYBOLTING DEVICE CONTROLLED BY LOCK, THICKNESS OF MS SHEET USED FOR SHUTTER: 0.7 MM, THICKNESS OF MS SHEET USED FOR SHELF: 0.7 MM, THICKNESS OF MS SHEET USED FOR TOP,BOTTOM, BACK AND SIDES: 0.7 MM, MATERIAL OF HANDLE: CAST BRASS, THICKNESS OF TRANSPARENT GLASS IN SHUTTERS: 4.0 MM, THE COMPLETE STEEL STRUCTURE SHALL BE CONSTRUCTED BY WELDING AND PROVIDE FINISHING WITH EPOXY POLYESTER POWDER COATED TO THE THICKNESS 60-80 MICRONIN COLOR GREY-LIGHT GREY. 64 Suppling of 3 Seater Public Place Seating Chair of mildsteel with arm and backrest WITHOUT CUSHION DURIAN,THREE SEATERTYPE WAITING AREA CHAIR -NIXON/SS/3 MATERIAL : STAINLESS STEEL,SIZE 1820MM(L)X 690MM(D)X 790MM(H)COLOUR : SILVER/WEIGTH OF PRODUCT : 34 KG APPROX,* SUPPLYING AND PLACING IN POSITION OF A STAINLESS STEEL VISITOR BENCH OF SIZE IS 1820MM(L)X 690MM(D)X 790MM(H). THE COMPLETE STAINLESS STEEL BENCH HAS SEAT & BACK SINGLE SECTION. PER SEAT LENGTH IS @ 520 MM &SEATING HEIGHT IS @ 430 MM FROM GROUND . OWING TO THE SMOOTH FINISH, DURABILITY AND TENSILE STRENGTH BEAM STAINLESS STEEL MADE BY 1.6MM THICK.SEAT IS MADE BY 1.2MM THICK STAINLESS STEEL BORDER WITH CHROME PLATING FOR EVERY SEAT & BACK ; STAINLESS STEEL HANDLES CHROME PLATED & DIE PRESSED LEGS AT THE END OF CHAIRS.GROSS WEIGHT OF REGULAR 3-SEATER WILL BE 34 KG.THE STEEL GRADE 202 HIGH YIELD STRENGTH AS PER IS:513 & IS:304 GRADE. 65 PROVIDING & SUPPLYING ANGLE RACKOF SIZE 900MM(L)X 450MM(D)X 1800MM(H) SLOTTED ANGLE RACK (OPEN TYPE) 6 SHELVES INCLUDING TOP & BOTTOM,ANGLES : 40MM X 40MM X 2MM(THICK).,SHELF : 36X15X1MM CRCA SHEET.IN COLOR GREY. 66 PROVIDING & SUPPLYING * FIX CANTILEVER CHAIR PROVIDING & SUPPLYING* ALL OVER SIZE IS : 590MM(L)X 490MM(D)X940MM(H) ,*THE CHAIR MADE OF FULL LEATHERETTE IN BLACK COLOUR .IT WILL COMES IN MATTE FINSIH IN CONTEMPORARY STYLE .DETAILS :* ARMS : PADDED ARMREST.* USE OF PLY: SEAT & BACK PLYWOOD MADE OF 12 MM HOT PRESSED.* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 35 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT* ONLY SEAT SIZE IS 590MM(L)X 490MM(D)X450MM(H) SEAT HEIGHT IS @ 450MM .* BASE : 2 CHROME LEGS + BACK SIDE BOTTOM CHROME IN METAL . 67 * SUPPLYING AND PLACING THREE SEATER EXCLUSIVE PREMIUM LEATHERETTE MODERNIST CLASSIC DESIGN LOUNGE SEATING SOFA SIZE IS 1650MM(L) X750MM(D)X 710MM(H) WITH KILN-DRIED WOOD FRAMING MAKES IT WARP AND SCRATCH RESISTANT,COMFORTABLE SEAT DEPTH & HEIGHT DESIGNED KEEPING MODERN INDIAN LIFESTYLE IN MIND,WRAPPED IN BUTTERY-SOFT PREMIUM LEATHERETTE, THE PANELLED BACK AND CUSHIONED ARMRESTS ENCOURAGE LOUNGING,DESIGNED WITH MODERNITY & ELEGANCE, CHOOSE THE OPTION THAT SUITS YOUR HOME.* COMBINATION CONSTRUCTION STRUCTURE ARE MADE INMOISTURE CONTENT SHALL BE LESS THAN (10-12)%. THICKNESS OF PLYWOOD USED (MM) SHALL BE 12 MM GRADE IS 303 INDIAN STANDARD FOR COMMERCIAL (COMMON) AND MOISTURE PROOF PLYWOOD (TENTATIVE).UNDERSTRUCTURE FRAME SHALL BE CONSTRUCTED FROM 18 MM THICK KILN-DRIED GERMAN BEECH WOOD FRAMING IS HIGHLY DURABLE. THE COMPLETE STRUCTURE SHALL BE COVERED BY P.U.FOAM FIXED WITH ADHESIVE GLUE ,THE FRAME SHALL BE PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING 25 +/- 5 DENSITY IN SEAT IT SHALL BE STACK FOAM OF 40MM THIK,40MM THICK BACK FOAM HAVING 25 +/- 5 DENSITY FOAM USED ,THERE SHALL BE CUSHION ARM 40MM THICK PROVIDED PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING DENSITY 25 +/- 5. THE COMPLETE STACK FOAM STRUCTURE SHALL BE COVERED WITH PREMIUM LEATHERETTE IN BROWN-CAMEL BROWN COLOUR, IT COMPLEMENTS THE MODISH SLEEK STEEL . ( SEAT : 545 MM(D) X 410MM(H) , ARMS HEIGHT @ 610 MM /BACK HEIGHT @ 290 MM). 68 SUPPLYING AND PLACING30 SEATER U - shape MEETING TABLE with table top of Three Layer Prelaminated ParticleBoards Of Grade-II Type-II Of IS:12823/Latest (for 14 seater rate devided by 30X24} 69 SUPPLYING AND PLACING PREMIUM SUITESDIRECTOR TABLE STRUCTURE OF L-SHAPED DESK .PRIMARY WORK SURFACE OVER ALL SIZE IS 2400MM(L)X 2330MM(D)X 770MM(H) 45MM THICK TABLE TOP MADE OFSUPPLYING AND PLACING PRELAMINATED PARTICLE BOARD WORK SURFACE WITH RICH CHERRY FINISH SAME MATCHING EDGE BANDING MADE OF SAME RED CHERRY P.U POLISH.MODESTY IS DESIGNED WITH LEATHER PATCH.SIDE PANNEL IS MADE OF 36MM THICK .* PROVISION OF SIDE UNIT OF SIZE IS 1200MM(L)X 595MM(D)X 770MM(H) ,(COMBINATION CONSTRUCTION ON TABLE TOP WIRE MANAGEMENT 2 HOLE WITH SS GROOMENT & 1 HOLE WITH PVC GROOMENT ON TOP SIDE UNIT. BELOW TABLE TOP ONE KEYBOARD TRAY,IN SIDE UNIT BELOW THE TOP 1 KEY BOARD TRAY,1 OPEN BOX FILE ,1 DRAWER + 1 OPEANABLE DOOR SHELVE. * FIXED PEDESTAL OF SIZE450MM(L)X 400MM(D)X 690MM(H) , HAVING 3 EQUAL DRAWERS IN PROVIDED WITH CETNRAL LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING. OVERALL CONSTRUCTION OF PEDESTAL IS 18 MM ALONG WITH FECIA OF DRAWERS. * ALL THE MDF BORAD ARE IS-14587-1998 WITH CONFIRM TO DIN 68861.ISO 9001- 2015 QUALITY CERTIFICATION CONFIRMING TO ASTM D 4499 STANDARDS FOR VISCOSITY AND THERMAL STABILITY . 70 SUPPLYING AND PLACING* HIGH BACK 360° DEGRE REVOLVINGCHAIR * ALL OVER SIZE IS : 673MM(L)X 508MM(D)X1270MM(H) , *THE CHAIR MADE OF FULL NATURAL LEATHER IN BROWN COLOUR . IT WILL COMES IN MATTE FINSIH EXTRA PADDED DESIGNED FOR MORE CONFIRMT AT WORKPLACE IN CONTEMPORARY STYLE . DETAILS :* ARMS : WOODEN ARMS WITH LETHER PADDING ARM REST ARE FITTED TO THE SEAT & BACK.* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) .* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT . * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK .BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT* MECHANISM : MULTI-LOCKING KNEE TILT MECHANISM .SEAT MAXIMUM HEIGHT IS 580MM & MINIMUM HEIGHT IS 500MM & BACK HEIGHT FROM FLOOR MAXIMUM HEIGHT IS 1270MM & MINIMUM HEIGHT IS 1219MM* GAS LIFT 80MM TELESCOPIC HAUDRAULIC * BASE : THE PRONG (BASE) IS MADE OF SOILD WOOD WITH POLISHEDAND FITTED WITH 5 NUMBERS. TWIN WHEEL CASTORS (CASTOR WHEEL DIA. 50MM) & 700MM PITCH CENTER DIA (740MM WITH CASTORS) . 71 SUPPLYING AND PLACING Material & Subtype Leather - Semi Aniline Leather,Metal - Stainless Steel,Frame Material Solid Wood Upholstery Material Leather,Seat Material Leather Leg Material Metal,Finish Matte,Colour & Colour Family Beige - Mushroom,Dimension (W)1140mm X (D)1000mm X (H)940mm Mechanism Click Clack Mechanism,Seating Capacity 1 Seater Seating Height 430mm,Function Adjustable Headrest Size Grand. 72 SUPPLYING AND PLACING Material & Subtype Leather - Semi Aniline Leather,Metal - Stainless Steel,Frame Material Solid Wood,Upholstery Material Leather,Seat Material Leather,Leg Material Metal,Finish Matte,Colour & Colour Family Beige - Mushroom,Dimension (W)2130mm X (D)1000mm X (H)940mm Mechanism Click Clack Mechanism,Seating Capacity 3 Seater Seating Height 430mm,Function Adjustable Headrest Size Grand. 73 SUPPLYING AND PLACING Rectangular CENTRE TABLE with Marble Top of 1219mmX711mm,(DAISY/CT (W)1300mm X (D)650mm X (H)450mm),Specifications:Number of storage under top No storage,Top material,Tempered glass,Frame material No frames,Dimension of Top (Length X Breadth, or Diameter) ±20mm,762mmX457mm,Height of centre table ±10mm,410,millimeter,Thickness of top material (+/-2 mm)- 8 millimeterThickness of frame material (+/- 1 mm)-10 millimeter 74 SUPPLYING AND PLACING 14 SEATER oval MEETING TABLE with table top of Three Layer Prelaminated Particle Boards Of Grade-II 75 SUPPLYING AND PLACING 6 Seater Sofa Material & Subtype-Premium Leatherette,Frame Material Solid Wood,Upholstery Material Premium Leatherette,Filling Material Foam,Silicone Fiber,Seat Material Premium Leatherette-Leg Material Solid Wood,Finish Matte,Colour & Colour Family Brown -Coffee Brown Dimension (W)4865mm X (D)960mm X (H)820mm,Seating -Capacity 3 Seater,seating Height 475mm,Size Standard 76 SUPPLYING AND PLACING9 SEATER U -* PROVIDING & SUPPLYING U - SHAPE MODERN DESIGN CONFERENCE TABLE & IN BETWEEN U SHAPE TABLE TOP LENGTH IS @ 4650 MM, TABLETOP OFFERS YOU A GENEROUS WORKSPACE,DESK PRIMARY WORK SURFACE USE PREMIUM QUALITY MATERIALS OVER ALL SIZE IS 4650 MM(L)X 600MM(D)X 750MM(H) TABLE TOP MADE OF 36MM THICK WHICH GIVE MORE SURFACE AREA FOR WORK ,MACHINE MADE MODULAR FURNITURE MADE PRELAMINATED PARTICLE BOARD OF GRADE II TYPE III OF IS 12823/LATEST,* CONSTRUCTION PROVISION OF CONFERENCE TABLETOP SUPPORTED WITH 18MM THICK SIDE PANNELS IN BROWN-BLACK OAK COLOUR MADE BY PRELAMINATED PARTICLE BOARD AND BELOW THE TOP 18MM THICK PRELAM PARTICLE BOARD MODESTY PANEL.OUR WORK SURFACE FURNITURE IS FINISHED WITH EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE,FIXED WITH HOT MELT GLUE. * THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATESt. 77 * SUPPLYING AND PLACING THREE SEATER EXCLUSIVE PREMIUM LEATHERETTE MODERNIST CLASSIC DESIGN LOUNGE SEATING SOFA SIZE IS 1650MM(L) X750MM(D)X 710MM(H) WITH KILN-DRIED WOOD FRAMING MAKES IT WARP AND SCRATCH RESISTANT,COMFORTABLE SEAT DEPTH & HEIGHT DESIGNED KEEPING MODERN INDIAN LIFESTYLE IN MIND,WRAPPED IN BUTTERY-SOFT PREMIUM LEATHERETTE, THE PANELLED BACK AND CUSHIONED ARMRESTS ENCOURAGE LOUNGING,DESIGNED WITH MODERNITY & ELEGANCE, CHOOSE THE OPTION THAT SUITS YOUR HOME.* COMBINATION CONSTRUCTION STRUCTURE ARE MADE INMOISTURE CONTENT SHALL BE LESS THAN (10-12)%. THICKNESS OF PLYWOOD USED (MM) SHALL BE 12 MM GRADE IS 303 INDIAN STANDARD FOR COMMERCIAL (COMMON) AND MOISTURE PROOF PLYWOOD (TENTATIVE).UNDERSTRUCTURE FRAME SHALL BE CONSTRUCTED FROM 18 MM THICK KILN-DRIED GERMAN BEECH WOOD FRAMING IS HIGHLY DURABLE. THE COMPLETE STRUCTURE SHALL BE COVERED BY P.U.FOAM FIXED WITH ADHESIVE GLUE ,THE FRAME SHALL BE PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING 25 +/- 5 DENSITY IN SEAT IT SHALL BE STACK FOAM OF 40MM THIK,40MM THICK BACK FOAM HAVING 25 +/- 5 DENSITY FOAM USED ,THERE SHALL BE CUSHION ARM 40MM THICK PROVIDED PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING DENSITY 25 +/- 5. THE COMPLETE STACK FOAM STRUCTURE SHALL BE COVERED WITH PREMIUM LEATHERETTE IN BROWN-CAMEL BROWN COLOUR, IT COMPLEMENTS THE MODISH SLEEK STEEL . ( SEAT : 545 MM(D) X 410MM(H) , ARMS HEIGHT @ 610 MM /BACK HEIGHT @ 290 MM) 78 SUPPLYING AND PLACING Wooden Acoustic Wall Cladding/Panelling- Providing and fixing in position wood wall paneling of width 128mm, thickness of 16mm and length 2440 mm made up of high density fiber board with minimum density of 800 Kg/m3 substrate with a laminated facing/wood veneer as per the approved shade/species & finish with melamine balancing layer on the reverse side. The boards shall have a special perforation pattern of 2mm groove & 14mm pitch. The panels shall have fire resistance of Class 1, BS 476 part 7. The edges of the panels shall be tongued-and-grooved to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece and backed with 50mm thick glass wool layer as directed by the Engineer-in-Charge. The panel shall be mounted on special channels using clips as approved by the Engineer -in-charge. Install Gel stud of section 48X34X36 mm or as approved by the Engineer -in- Charge on the solid wall horizontalty using screws and plugs at spacing of 600mm centre-to-centre, Screw the aluminium channel (keel) vertically on channeled G.I stud 600mm 79 SUPPLYING AND PLACINGBlackout roller blind,Specifications-Mounting arrangement profile systems – clicked on hidden mounting clipsTypes of roller blind,Blackout roller blind-Shading solutionSingle roller blind – utilise one layer of fabric (called outer layer Operating mechanism-Side winders (that lock the manually adjustable blinds at different levels with the internal ratchet and tension adjusted by spring inside the tube) 80 Providing and Fixingof Drawers in Brown Finish ,Specification-Material : High QualityParticle board Dimensions (In Centimeters)-H 91 x W 90 x D 44 Dimensions (in Inches)-H 36 x W 35.5 x D 17.5 Primary Material-Engineered Wood as per Engineer incharge 81 Providing and FixingSTAGE - Providing & fixing raised stepped floor (Stage) Consisting ofMS Tabular frame work ofPipe Section (HOT ROLLED/COLD ROLLED) size 50mmx 50mmx2.0mm.tk. duly Painted with one coat of Red Oxide steel Primer, fabricated in module of 600 x 600 mm frame gid (as per Design or as instructed) with support of same section Legs /frame fixed on existing floor from base and raised at height minimum 150mm to max 200mm as required, from Existing floor. Vc providing and fixing 18mm thick heavy duty high density (1450 kg/cum) cement fiber Board fixed by SS. Screw on Horizontal & Vertical Surface on Existing Framework with one coated cement primer on Board and covering Board from top and sides by 2mm thick Vinyl flooring of approved make,colour and texture to be layed and fixed on sub floor smoothly finished and levelled by recommended adhesive cutting fixing and including covered raised portion of Board from all sides etc. complete,suitable for use up to the satisfaction of Engineer- in-charge.Design as approved by Engineer-In-charge. Base ofthe Vertical Legs of M.S. Frame (COLD ROLLED/HOT ROLLED) 82 Providing, fixing & installation MICROPHONE:-Flat frequency response across the vocal range for uncolored sound interchangeable cardioid, supercardioid, and omnidirec- tional cartridges that provide choices for applications Sleek, low-profile design for unobtrusive appearance Balanced transformerless output for increased immunity to noise over long cable runs-Compact Cinema Surround Speaker for Digital Applications:- Frequency range: 50 Hz to 20 kHz • High sensitivity: 91 dB SPL, IW @ 1m (3.3 ft) High power handling capability: 150 watts, continuous pink noise Internal Thermomaster• technology allows for unprecedented high frequency power in a compact, molded enclosure Convenient mounting design supports JBL QuickMountre, OmniMount• or APC multimount brackets Special cabinet shape incorporates 20• angled front baffle SMPTE/lS02969 Curve X high frequency de-emphasisMixer 8 input mono mixer XLR input switchable between mic and line level +/- 15dB gain trim control per input Input 1 is switchable to be pre/post master 24VDC or mains power operation Optional remote VCA/Tone generator/ Muting boards available • Whisper quiet operation 83 Supply, Installation, Testing and commissioning of microphone Delegate unit. 84 Supply, Installation, Testing and commissioning of microphone Chaiman unit, 85 Supply , Installation , testing and commissioning of Factory made 1.4HDMl Cable along with connector (15mtr length) 86 Supply , Installation , testing and commissioning of Factory made VGA along with Connectors.(15mtr length) 87 Supply , Installation , testing and commissioning of Factory made RCA along with Connectors.(15mtr length) 88 Supply , Installation , testing and commissioning 40W power Amplifier of following features:- Rated output wattage - 240W, amplifier output IOOV, 70V and 4-16 ohms transformer isolated speaker outputs, Supply input 0.775 v (OdB) unbalanced, 10k ohms, XLR and phone jack frequency 89 Supply , Installation , testing and commissioning10W wall mount speaker- Supplying, installation, testing and commissioning of 240W power amplifier with following features:- Rated output wattage- 240W, amplifier output 100V, 70V and 4-16 ohms transformer isolated speaker output, Supply input 0.775 v (0 db) unbalanced, 10k ohms, ZLR and phone jack frequency response 50 - 18000 Hz, +/- 1.5 dB, S/N ratio > 105 dB. 90 Supply , Installation , testing and commissioningCONFERENCE CONTROL UNIT, line Output 1 17.5V DC/3a Max.; -34dBV (20mV), line Output 2 17.5V DC/3a Max.; -34dBV (20mV), power Output 50w rMS at 2% THD, 90w Max. inputs 3xMic 0.65mV/4.7kQ Ixaux IOOmV/470kQ Frequency response 60-14,000Hz (± 3dB) 91 Supplying of Material & Subtype Engineered Wood Finish Matte,Colour & Colour Family Brown - Wenge Dimension (W)800mm X (D)384mm X (H)1970mm Size Standard,Style Contemporary,Assembly Type Knock Down 92 Supplying of Powder Coated Extruded Aluminium Sections Hybrid panel based system (combination of sliding & snap fit tiles) Modular Work Stations 93 Supplying of11 SEATER U - shape MEETING TABLE with table top of Three Layer Prelaminated Particle Boards Of Grade-II Type-II Of IS:12823 94 SUPPLYING AND PLACINGSLOTED ANGLE RACKOF SIZE 900MM(L)X 450MM(D)X 1800MM(H) SLOTTED ANGLE RACK (OPEN TYPE)6 SHELVES INCLUDING TOP & BOTTOM,ANGLES : 40MM X 40MM X 2MM(THICK).,SHELF : 36X15X1MM CRCA SHEET.IN COLOR GREY, 95 SUPPLYING AND PLACING : METAL STORAGE OF SIZE 900MM(L)X 450MM(D)X 1980MM(H) BODY MADE OUT IN 22 GAGUE(0.8MM) & DOOR 19 GAGUE(1 MM) CRCA SHEET. 4 ADJUSTABLE SHELVE IN 22 GAGUE(0.8MM) & PEDESTAL 18 GAGUE 1.2 MM CRCA SHEET. HAVING FOUR SHELVES MAKING FIVE COMPARTMENT, UNIFORMLY DISTRIBUTED LOAD CAPACITY OF EACH SHELF SHALL BE 60 KG MAXIMUM,FITTED WITH MS BODY LOCK & HANDLE. FINISHING WITH EPOXY POLYESTER POWDER COATED TO THE THICKNESS 50-60 MICRONS(+/-5 MICRON)IN COLOR GREY-LIGHT GREY. 96 Providing and fixing e Slimline Tower AC (2 Ton White),Availability of BIS/ISI Mark Certification for Split AC Floor type-Yes,Technology of air conditioner,Non Inverter AC-Nominal Marketing capacity as per BEE Star Rating Label (hint: 1 Ton = 3000 Kcal/Hr, Tolerance +/- 10%) (in Ton)-3 BEE Star rating of the product (Central Ministries/Departments while procuring shall ensure that the items carry 5 star (under normal conditions where annual usages is expected to be more than 1000 hrs),3 Star (where usage is Limited)or higher Star R NA- Star rating for the capacity of >10,465 Watts (>9,000 kcal/hour) 97 Providing & Fixing 2.0 mm thick homogenous single layered vinyl flooring. The flooring shall be laid in manner to provide comfortable and jerk free surfaces including material, adhesive, scaffloding and lead and lift at all floor level etc. complete as per direction and approval of Engineer-in-charge. 98 Providing & Fixing Wiring for Primary Raw Power point 2 sets of 6 Amp Switch-Socket Outlet with 2.5 sq.mm FR PVC insuate copperconductor wire in surface / recessed 25mm medium class PVC conduit, earthing the third point With 2.5 sq.mm FR PVC insulated copper conductor Wire. Including Providing and fixing 2 nos 6A Switch with Front plate and metal Box with all Accessroies for users. 99 Providing & Fixing Wiring for Secondry Raw Power point 2 sets of 6 Amp Switch-Socket Outlet with 2.5 sq.mm FR PVC insulated copper conductor wire in surface / recessed 25mm medium class PVC conduit, earthing the third point with 2.5 sq.mm FR PVC insulated copper conductor Wire. Including Providing and fixing 2 nos 6A Socket controlled by 1 nos 6A Switch with Front plate and metal Box with all Accessories. 100 Providing & Fixing Wiring for Primary Raw Power point 1 sets of 6 Amp Switch-Socket Outlet with 2.5 sq.mm FR PVC insulated copper conductor wire in surface / recessed 25mm medium class PVC conduit, earthing the third point with 2.5 sq.mm FR PVC insulated copper conductor Wire. Including Providing and fixing 1 nos 6A Socket controlled by 1 nos 6A Switch with Front plate and metal Box with allAccessories. 101 Providing & Fixing Wiring for Secondry Raw Power point 1 sets of 6 Amp Switch-Socket Outlet with 2.5 sq.mm FR PVC insulated copper conductor wire in surface / recessed 25mm medium class PVC conduit, earthing the third point with 2.5 sq.mm FR PVC insulated copper conductor Wire. Including Providing and fixing 1 nos 6A Socket controlled by 1 nos 6A Switch with Front plate and metal Box with allAccessories. 102 Wiring for Primary Power point 6/16 Amp Switch-Socket Outlet with 4 sq.mm FR PVC insulated copper conductor wire in surface / recessed 25mm medium class PVC conduit, earthing the third point with 2.5 sq-mm FR PVC insulated copper conductor Wire. Providing and fixing 1 nos 6/16A Socket controlled by 1 nos 16A switch with front plate and metal box with allAccessories. 103 Providing & Fixing Standing Bathtubs Specifications:Size:1690x800x445/565mm Free Standing Bath Tub with Over Flow & Drain 104 Providing & Fixing Corazzin Garden Patio Seating Chair and Table Set Outdoor Balcony Garden Coffee Table Set Furniture with 1 Table and 4 Chairs Set (Black) 105 Providing & Fixing Reliable Drapes Cotton Plain Door Curtains Reliable Drapes,Cotton GSM Quality-220,Lining included-No, Pack of-1,Length (Ft)-8.5-9,Width (Ft)-3-3.5 106 Providing MattressDimension 1981 mm X 1829 mm,Thickness of Core Layer (Height of Spring) 200 mm,Thickness of Felt (±1 mm) for Bonnell Spring 12 mm,Thickness of Top Layer (±2 mm)-50 mm Thickness of Bottom Layer (±2 mm)50 mm,Type of Spring in Core Layer Bonnell Spring (with cotton felt),Material of Top Layer Visco Elastic PU Foam (Memory Foam) 107 ProvidingCotton Pillow 33 cm x 56 cm (COTTON PILLOW)of Specification-BIS Marking ( For Body Casing fabric )-No Logo Marking-No,type of Logo,Stitched ( Patch Logo ),Agree to provide 108 Providing240 centimeter x C1112M 135 centimeter (L x W) Printed Bed Sheets(BED SHEET ):Technical Specification of the Product-Sheeting, Tickings and Bedsheets (V2) as per IS 175 BIS Certifcation-No,VarietyVariety - 2,Process of colouring Dyed,Matching Pillow cover 109 Providing 25 liter 3 Star Water Heater,25 Ltr 5 Star Water HeaterCapacity litres (Litres),BEE Star Rating (Central Ministries/ Departments while procuring shall ensure that the items carry 5 star or higher Star Rating of BEE)-3,Availability of Type Test Report from Central Govt/NABL/ILAC accredited lab to prove conformity to specification-No,Material of Inner Container Vitreous enamelled inner tank conforming to IS-13273 110 Providing Wall Mount Mesh Filter T-Shapped Kitchen-Chimney Material of Blower Body-Aluminium,Material of Blower Blade Aluminium,Material of Exhaust pipe-pvc,Filter Material,Stainless Steel,ShapeT-Shapped,Filter Type,Mesh Filter,Control Panel Type Soft Touch,Mount Type,Wall Mount 111 Providing Potable Water Purification System With Inbuilt Water Cooler. RO UV Aquaguard(Hot & Cold uv+ ro) Specifications-Flow rate (Litres/hr.)-12,Cold water storage capacity (Litres)-11 liter,Cooling capacity (litres/hr.)-4,Hot water storage capacity (Litres)-1.5 liter,Heating capacity (litres/hr.)-1.5,Cooling power consumption (Watts)-230,Heating power consumption (Watts)-550. 112 Providing300 L 3 Star Frost Free Double Door Refrigerator, of specification Cooling type:Frost free,Exterior body built:steel,Shelf material -Toughened glass,Voltage Range-160-300V,frequency-50 Hz 113 Providing900 mm wide 2000 mm high Metal Shelving Racks,Specifications :Type-OPEN TYPE Number of Shelves/Compartments (Top / Ceiling Shelf - not to be counted)-4,Shelves Material-0.8 mm Thick MS Sheet Conforming to Commercial Quality CR-1, Grade 340 of IS 513,Depth in mm (±5 mm)-400,Width in mm (±5 mm)-900,Height in mm (±5 mm) 2000 114 Providing and fixing Drawers of Specification of Dimension (in cm)-H91 X W90 X D44in Brown Finish,primary material-Engineered wood,Weight 49.45kg 115 Providing and fixingDressing Table With cupboard and open shelves-Design of Dressing table With drawers,cupboard and open shelvesBase of dressing table Rectangular wooden frame Number of side mirror-1 number, Material specification-Prelaminated particle board of grade II type III of IS 12823/Latest.both side laminated. outer side laminated with shade matching with top shade and fascia shade and having balancing laminate of 0.5mm thick on other side Material thickness of complete body, Fascia and drawer/cupboard-19 millimeter,Material thickness for back, partition and drawer /cupboard bottom ± 2mm,19 millimeter 116 Providing and fixing Material & Subtype Solid Wood - Rubber Wood Table Top Material Solid Wood-Frame Material Solid Wood,Finish Glossy,Colour & Colour Family Brown - Walnut Dimension Of Table (W) 600mm X (D) 600 X (H) 610mm Dimension Of Chair (W)640mm X (D)530mm X (H)560mm Size Standard 117 Providing and fixing Wooden Double Bed Storage Box Opening From Material of Mattresses Panel-Other wood, Material of Bottom Panel of Storage Box-Three layer prelaminated particles board (Wood product) of grade II type II of IS 12823/Latest Material of Front, Back and side Panels Three layer prelaminated particles board (Wood product) of grade II type II of IS 12823/Latest Material of Headrest Three layer prelaminated particles board (Wood product) of grade II type II of IS 12823/Latest Material of Legrest-Three layer prelaminated particles board (Wood product) of grade II type II of IS 12823/Latest,Type of Bed-Wooden Double Bed Material of Bed Frame-Three layer prelaminated particles board (Wood product) of grade II type II of IS 12823/Latest 118 Providing and fixing 1 Seater Sofa With Leatherite Cover Sofa Set is Foldable to use as bed-No Backrest Cushion Material-Foam,density of Cushion of Backrest Material (Kg/Cubic M)-40 Covering Material for Seat and Backrest Fabric Frame Structure Material and size (±1 mm) Any other wood of minimum 25 mm thickness Seat Cushion MaterialFoam 119 Providing and fixing 8 SEATER Rectangular MEETING TABLE with table top of Three Layer Prelaminated Particle Boards Of Grade-II Type-II Of IS:12823/(Elanor Marble 8 Seater Dining Set) 120 Providing and fixing MODULAR TABLE L X D & H 2000 millimeter X 450 millimeter 700 millimeter (Alice TV Unit marble),Sprcification-Mode of Supply of modular table Knocked Down to be assembled at consignee site by the Seller Storage Provided one side,Number of storage unit-triple storage,Table Top material and thickness ±3mm-25mm thickness three layer pre-laminated Particle boards (Wood Product) of grade II Type II of IS 12823 Latest Gable end and modesty panel material and thickness-18 mm thickness three layers pre-laminated Particle boards (Wood Product) of grade II Type III of IS 12823 Latest 121 Supplying of Library Management Department. and NDL Softwares,Server Machines, Air-Condition Systems,Xerox Machines,Lamination Machines, CONNECTION)Binding Machines,Furniture/Furnishing. Computers, Printers,Computer System(with Internet Connection) 122 Supplying of Printer of Specification A Printing Technology Laser-Cartridge Technology,Composite Cartridge,Type of Printing Mono,Paper Size-A4 Print Speed per minutes per Department Incharge 123 Supplying of XEROX Machine(standard company) Type of MachineMultifunction Machine,Print Technology-Laser Type of Printing-Mono,Cartridge Technology Separate Drum and Toner (Dual Component) Platen/Flatbed Size-A3/A4,Paper Size (Original/Image)A3/A3 RAM size (MB)-4096as per Department incharge 124 Supplying of Determination of wavelength of He-Ne Laser light using Grating(Specification- Output Power: up to 15mW, CW - Wavelength: 632.8nm,* Mode Structure: TEM00 (>95%)* Beam size: <= 1mm* Beam Divergence: <= 1.5 mrad* Polarisation: Unpolarised, Vertical Polarisation. complete set up as per Department incharge 125 Supplying of Brewsters Law using spectrometer(Brewsters angle apparatus differ goniometer digital research bench polarizer analyser with rail type bench abron). complete set up as per Department incharge 126 Supplying of Determination of wavelength of Sodium light using Michelson interferometer(Power-3 kW,Usage-Physics Lab,Material-Mild Steel,Power Source,Electric Voltage 240 V). complete set upas per Department incharge 127 Supplying of Determination of wavelength of Sodium light using FabryPerot interferometer complete set up of Specification Flatness of Reflective Mirrors-λ/20 Diameter of Reflective Mirrors-30 mm Reflectance of Mirrors-95% Effective Travel of Preset Micrometer~ 3 mm Min Division Value of Preset Micrometer-0.01 mm Travel of Fine Adjustment of Movable Mirror-1.25 mm Resolution of Fine Adjustment-0.0005 mm Low-Pressure Sodium Lamp-20 W as per Department incharge 128 Supplying of Resolving Power of Telescope complete set up (specification Color-BlackMaterial-Plastic as per Department incharge) 129 Supplying of Resolving Power of Prism(Resolving power of telescope assists the user to know the basic principle of telescope. Fabricated using excellent quality metals, glass and plastic material, it is widely used instrument in scientific lab of colleges and research centers. It is known for accurate calculation and longer service life) complete set up as per Department incharge 130 Supplying of Production and analysis of Polarised light using half and quarter wave plate(Usage/Application Laboratory Voltage-230 V,Color-Black,Material-SS). Complete set up as per Department incharge 131 Supplying ofLogarithmic Amplifier(Built in power supply : +15V & -15V DC,Mains : 230V AC,Dimension : 27CMS X 17CMS [metal cabinet,Weight : 2KGS APPX) complete set up as per Department incharge as per Department incharge 132 Supplying of Zener diode characteristics & voltage stabilizer. Complete-Specification:(Voltage-240 V Frequency-60 Hz,Display Type -Analog)in all respect as per Department incharge 133 Supplying of FET characteristics complete up(Technical specifications-Inbuilt variable, overload & short circuit protected DC regulated power supplies of 0- 5 volt & 0- 15 volt.Voltmeter & ammeter are mounted on the front panel.One FET.Highly insulated front panel .Trainer helps to demonstrate the working principle of FET.Set of required number of patch cords.Multi - colored sockets are used.Housed in an elegant powder coated metal cabinet.Strongly supported by a comprehensive instruction manual complete with theory and operating details.LED indication for supply “ON” to work on 220V AC Mains.) as per Department incharge 134 Supplying of MOSFET characteristics complete set up(Specificaion:Power-AC Mains,Usage/Application-Laboratory Type-Analog,Material-plastic,Power Supply-ac mains, as per Department incharge 135 Supplying of UJT characteristics complete set up(Specification-Usage/Application-laboratory,Type-Analog,Display Type-Analog meters,Power Supply-ac mains)as per Department incharge 136 Supplying of Transistor biasing (CE mode)(Specificaion-Operating Power Supply-220VAC On Board Power Supply 0-1VDC & 0-10VDC Experiment Input & Output Char In CB & CE Mode OF PNP Tr.Meter Type Analog / Digital)set up as per Department incharge 137 Supplying of Characteristics of SCR(SpecificationUsage/Application-laboratory Type-Analog Automation Grade-Manual ,Power Supply-ac mainscomplete set up as per Department incharge 138 Supplying of Basic Logicgates and Universal gates. Operating Supply Voltage 230V,Logic Family-DIGITAL,Number of Inputs per Gate-2,Usage Laboratory,Material-ELECTRONIC Complete set up in all respect as per Department incharge 139 Supplying of Op-amp Integrator &Differentiator. Complete set up in all respect :Product Specification:Type-Analog Material-Metal,Automation Grade=-Manual,Color-black with multicolour PVC front panel,Power Supply-230,Capacity--5,connector Type-patch cord sas per Department incharge 140 Supplying of Half Adder, Full Adder and 4-bit binary Adder. Complete set up in all respect (Product Specification:Type-Digital,Display Type-Digital Interface--NO Material-ABS,Display-Digital,Pulse Generator-50Hz Variable Dc Output-no)as per Department incharge 141 Supplying of G. M. Counter for 6 digits GM counter with built in power supply complete set up(G.M.COUNTER: COMPLETE WITH INBUILT POWER SUPPLY EHT 250-1200v Workable on 220v. 50Hz., Power consumption 8W approx. STOP, START, RESET switches. Counts Capacity : 6 DIGIT COUNTING SYSTEM, Preset time : 3 DIGIT PROGRAMABLE TIMER WITH DIGITAL DISPLAY. 3 ½ Inbuilt Digital Volt Meter for GM TUBE Voltage. G.M.TUBE: END WINDOW G.M.TUBE MOUNTED IN ACRYLIC STAND. WITH ‘LEAD’ AND ‘ALUMINIMUM’ ABSORBENTS, Radioactive Source: ONE RADIOACTIVE SOURCE BETA or GAMMA (in Lead Container and wooden Box) SOURCE, . Dimensions : 460X370X230mm.(Complete instrument is HOUSED in corrugate box with Export Packaging) Wight : Total weight of the Instrument is 5.5kg.) as per Department incharge 142 Supplying of Measurement of Dielectric constants of solid and liquid samples complete set up(It Consists of following partsRF Generator (9-10MHz Approx) Micro Ammeter (Range 0-50mA) Potentiometer for Sensitvity Selection Fixed Capacity (Metal) Variable Gang Capacitor Socket for test Capacitor & Variable Capacitor brought out at front panel One Solid bakelite plate to be insert in gap of test capacitors)as per Department incharge 143 Supplying of Study of Dielectric constants and Curie temperature of ferroelectric ceramics Complete in all respect(Specifications Temperature Range : Ambient to 200°C,Display : 31/2 digit, 7 segment LED with autopolarity & decimal indicationResolution : 0.1°C,Accuracy : ±0.5°C (typical),Stability : ±0.1°C Power : 150W,(ii) Digital Capacitance MeterThis a compact direct reading Instrument for the measurement of capacitance of the sample. Specifications,Range : 50-6000 pf,Resolution : 1pf Display : 3½ digit, 7 segment LED, Typical results obtained with the above set-up are as shown in the graph) as per Department incharge 144 Supplying of Determining Optical constants of a metal by reflection of light Complete in all respect (Specification-Power-AC Mains,Usage/Application-Laboratory,Type-Digital Material-Metal,Automation Grade Manual,Color-White Power Supply-AC Mains,Display Type-Digital) as per Department incharge 145 Supplying of Lattice dynamics kit with frequency meter (Technical Specifications: Audio Oscillator 100 khz,Built in Power Supply and Output Stage to match the Impedance of Simulated Lattice,Lattice DynamicKit consists of Transmission line, which Simulates One-Dimensional Mono-AtomicandDi-atomicLattices,. LCD Based Frequency Counter is Provided on panel to Measure Frequencycomplete set up as per Department incharge 146 Supplying of BCD to seven segments complete set up(Specification:Built in power supply : +5V DC Mains : 230V AC Dimension : 27CMS X 17CMS [metal cabinet] Weight : 2KGS APPX) as per Department incharge 147 Supplying of Monostable Multivibrator using Oscilloscope (CRO) complete set up (Specification:Usage/Application Laboratory Packaging Type-Corrugated Box,Connector-2mm sockets Frequency Range -50Hz) as per Department incharge 148 Supplying of Bistable multivibrator using Oscilloscope(CRO))Technical Specification:(Built in power supply : +12V & -12V DC Mains : 230V AC,Dimension : 27CMS X 17CMS [metal cabinet] Weight : 2KGS APPX)complete set up as per Department incharge 149 Supplying of Pulse code modulation and demodulation complete setup (Product Specification,Type Laboratory Trainer Kit Usage/Application-Laboratory,Accuracy-+/- 10%,Frequency-50 Hz Input Voltage-220V,Packaging Type-Corrugated Box,Power Source-ElectricShape-Rectangular,Material-ABS or Metal Cabinet)as per Department incharge 150 Supplying of Addition, Subtraction, Multiplication using 8086 microprocessor(Product Specification,Usage/Application-LaboratoryType-Fully Automatic,Automation Grade-Semi-AutomaticClock Frequency-Yes,Color-Green,Display-Digital Packaging Type-Corrugated Box, Power-200-400 Weight 2 Kg) as per Department incharge 151 Supplying of Thevenin theorem, (THEVENIN’S AND NORTON’S THEOREM APPARATUS,Technical specifications Inbuilt fixed DC regulated power supply of 12 volt. Voltmeter & ammeter are mounted on the front panel. Resistive network is used in the circuit. Circuit diagram is printed on highly insulated front panel . Trainer helps to demonstrate the working principle & verification of Thevenin’s & Norton’s Theorem based on resistive circuit. Student can calculate & measure the value of current & voltage for different load circuits. Calculation of power consumed by the circuit. Facility for connecting external Power Supply. Set of required number of patch cords. Multi - colored test points are provided in the circuit to observe voltages at different points. Housed in an elegant powder coated metal cabinet. Strongly supported by a comprehensive instruction manual complete with theory and operating details. LED indication for supply “ON” to work on 220V AC Mains. Circuit protection through glass fuse)Complete set up as per Department incharge as per Department incharge 152 Supplying of Active filter set up(Product Specification Operating Temperature-0-50,Frequency (Hz) 50,Condition-New Temperature (deg. Celsius)-50,Usage/Application Industrial, Educational, Residential, Commercial) as per Department incharge 153 Supplying of A to D counter type complete set up (Product Description-M-32 AD M-16 AD,Input AD: 1/4 TRS jack and 25 pin D-sub, servo balanced, completely symmetrical audio path, Output AD: 4 x ADAT optical, 1 x MADI optical/coaxial,Dynamic Range AD: 113 dB RMS unweighted, 116 dBA,THD AD: < -110 dB (< 0.00032 %),THD+N AD: < -104 dB (< 0.00063 %) Crosstalk AD: > 130 dB,Input level for 0 dBFS: +24 dBu, +19 dBu, +13 dBu,Frequency response AD, -0.1 dB: 10 Hz - 23.2 kHz (sf 48 kHz),Frequency response AD, -0.5 dB: < 5 Hz - 45 kHz (sf 96 kHz) Frequency response AD, -1 dB: < 5 Hz - 80 kHz (sf 192 kHz) Sample rates: 44.1, 48, 88.2, 96, 176.4, 192 kHz, variable (Sync/WC),Jitter: Typical < 1 ns for internal, Word Clock, ADAT and MADI input Jitter sensitivity: all PLLs operate error-free even at 100 ns,Jitter suppression: > 30 dB (2.4 kHz),Power supply: Internal switching mode PS, 100V - 240V AC, 60 Watt Dimensions: (WxHxD) 483 x 88 x 200 mm)as per Department incharge 154 Supplying of Determination of Plancks constant(1. 1 0-2V D.C. at 20mA Variable Power Supply. 1.2 Digital Panel meter 3½ digits range 2mA. 1.3 Digital Panel meter 3½ digits range 2 volt 02 Lamp House: 100W Bulb with stand 03 Vacuum Type Photo Cell : Mounted in a Iron box. 04 Three different colour optical filters 05 Adequate no. of patch cords stackable 4mm spring loaded plug length 50cm. 06 Strongly supported by detailed Operating Instructions, giving details of Object, Theory, Design procedures, Report Suggestions and Book References.) as per Department incharge 155 Supplying of Determination of Energy Band Gap using Four Probe method(Product Specification:Type-Energy Band Gap Usage/Application-Laboratory,Connector-4mm Banana Socket Frequency-50Hz) as per Department incharge 156 Supplying of Determination of Hall coefficient and Hall angle in Hall-effect(Product Specification,Display Type-0-20V DC, 0-5 A, digit LED, Primary safety socket,4mm Electro Magnet Coils 500 T, Voltage resolution -0.1V,Current Resolution 0.1 A) as per Department incharge 157 Supplying of Determination of magnetic susceptibility using Guoys method(Usage/Application Physics Laboratory Type Of Instruments-Magnetic Susceptibility Gouys Balance Method Experiment Setup,Power-230V , 50Hz, +-10% Display Type-LED Type) as per Department incharge 158 Supplying of Study of absorption pattern of a given sample using FTIR spectrometer(Product Specification,Detector-High performance pyroelectric infrared detector,Weight-15 kg Software-1,Voltage-100-240V AC,Electronic System-24bit A/D converter at 500KHz, USB 2.0,Wavenumber Range-7800~350 cm-1Power-100-240V AC,50/60Hz,Signal Noise Ratio-30000:1 (resolution@4cm-1 , sample and background scan for 1 min@2100cm-1 ),Light source-Long life, steady state infrared emitter Beam splitter-coated KBr,Resolution-1 cm-1,Dimension-430mm x 360 x200) as per Department incharge 159 Supplying of LCD Projector and smart board (Product Specification,Projection Distance-<1 m Resolution-WXGA,Lamp Life-5000/9000/10000 HOURS Screen Size-100,Display Type-LCD,Dimensions-400X367X149MM Connectivity Type-Dual HDMI, HDMI,Brightness-2000-4000 Lumens Color-White) as per Department incharge 160 Supplying of Desktop(ntel Core I3/ 10th Gen/ 4GB RAM/ 1TB HDD/ DOS/ NO DVD/ 19.5 Inch Monitor/ 1 Year Warranty) as per Department incharge 161 Supplying of Printer(Product Specification,Printer Type-Ink Tank Color Output-Color,Print Speed-22 ppm,Paper Size-A4,Dimension-403 x 369 x 150 mm,Weight -6,Warranty-One Year or 50,000 pages which ever is earlier) as per Department incharge 162 Supplying of Printer (Product Specification Printer Type-Inkjet Color Output-Color | B&W,Print Speed-10,Paper Size-A4,Connectivity-USB,Dimension-377 x348 x179,Weight-3.9 Print Volume-any)as per Department incharge 163 Supplying of XEROX Machine (Product Specification,Functions-Photocopy,Supported Paper Size-A3,Supported OS-Windows 10 Color Output-Black & White,Number Of Trays-1,Item Color-Black & WhitePrint Speed-22 PPM,Weight-40 kg,Print Technology-Laser Input Tray Capacity-350 sheets,Warm-Up Time-5.6 Sec,Duty Cycle-80000 / Month,Resolution-600 x 600 dpi Connectivity-Ethernet & USB,Duplexing-Yes)as per Department incharge 164 Supplying of computer system with internet connection,PC Specifications to be followed :Processor Intel Core i5(10th Gereneration or newer ),RAM-8 GB or Higher HDD:512 GB,SSD,Monitor 24 LCD Monitor .OS:Windows 10 Professional ,Anti virus:User Licence for one year as per Department incharge 165 Supplying of Laptop (with Internet connection),Processor intel Core i5(11th Generation or newer),RAM 8 GB or higher HDD:512 GB,SSD Monitor 14 screen ,OS Windows 10 Professional ,Antivirus :User Licence for one year 166 Supplying of LCD Projector (Specification-Brightness:2000-4000 Lumens,Resolution-FULL HD 1080P,Connectivity Type-Dual HDMI, HDMI Display Type-DLP,Power Supply-100-240V Portable-Yes) as per Department incharge 167 Supplying of Smart Board (Frame Material-Aluminium Usage/Application-School, Education, etc,Effective Touch Area-72 x 48 inch Material-Ceramic Input Method-USB Power Consumption-150 - 220 W,Shape-Rectangular) as per Department incharge 168 Supplying of MS Suite Software(Specification-Microsoft Office Software,Operating System:For Windows,Brand:Microsoft )as per Department incharge 169 Supplying of Adobe Photoshop Software(Specification -Graphic Design and Photo editing,Licence-1 yea) as per Department incharge 170 Supplying of windows10 OS Software(Specification-License Duration-Life Time,Architecture-32/64 Bits,Operating System For WindowsAlso Provides,Windows Operating System,Provide Installation Service-Yes Support 24/7 (Live Rep)) as per Department incharge 171 Supplying of Laptop of 11th Generation intel core i3,1115G4 processor (6 MB Cache up to 4.1GHZ)windows 10 Home Single language English,intel UHD Graphics with shared graphics memory 8GB ,8 GBX1,DDR4,3200 MHZ,512 MB,2 PCLeNVMe Solid state drive pebble (Top colour is pebble colour,Base and palmrest are black colour as per department incharge 172 Supplying of Desktop of 10th Generation intel core i5-10500T (6 CORE,12MB Cache 2.3GHZ to 3.8GHz,35W ),Windows 10 Pro (64 Bit )English,intel integrated graphics),8GB ,1X8 GB,DDR4 non-EC0C Memory,2.5 inch TB 7200 RPM ,SATA Hatd disk drive 5480AJO 23.8 FHD 1920X10080 ips non touch,Antiglare camera,integrated graphics,Bronze 1505w PSU as per department incharge 173 Supplying of Printer (Specification:Item Weight-12 Kg,Package Dimensions-60 x 56.5 x 38 cm,Connectivity Type-Wi-Fi Operating System-Windows)as per department incharge 174 Supplying of Fumehood(Specification:Type-exhaust,LED-Tube fitting,Power-230 volt,Working Top-Granite ,MOC-GI with PU coated Storage includedas per department incharge 175 Supplying of electronic balance(Specification -Usage/Application-Laboratory,Accuracy-0.01%,Calibration-Fully Automatic,Type Of Weighing Scale-Digital,Voltage-110-220 V Mounting Type Desktop) as per department incharge 176 Supplying of Magnetic stirrer Magnetic stirrer Hot plate (Specification-Weight-2.3 kg,Timer -999 minutes,Temp. Accuracy-+-1 Deg.C(<100 Deg.C)+-3 Deg.C(<300 Deg.C),Dimensions LxWxH (mm)-230 x 180 x 120,Max.Temp. (Plate Surface) 300 Deg.C,Power supply-AC 220V / 50 Hz,Top Plate Size 135 x 135 mm,Display-LCD,Max. Volume (ml) 2000 ml,Speed (RPM)-1250 RPM Plate Material Steel per department incharge 177 Supplying of HOT Air oven of made inner material-stainless steel,Outer material -mild steel ,Surface treatement -Powered coated ,Sizes-Different sizes,Gravity conviction type-Double wall.Mechnical conviction -Triple wall as per department incharge 178 Supplying of colourimetry , Ery colour colorimeter industrial and research purpose stability( Product Specification:Material-Aluminium Alloy,Automation Type Automatic,Brand -DD-LAB ,Dimension-210 x 160 x 80 mm,Display Type-Dual Digital DisplayLight Source-Highly Accurate Laser Source,Stability- + 0.02 O.D. Per Hour Volume 1 ml. minimum,Filters layer-Built in 9 Digital filters 30,000 hours Life,Weight-1.5 Kg,Battery Backup-6 V Ni CD Re-chargeable Battery,Detector Silicon Photo-diode,Display Model Absorbance & Wavelength,Filter Wavelength 680 NM Country of Origin Made in India) as per department incharge 179 Supplying UV-Vis Spectrophotometer Fully touch screen portable UV Spectrophotometer shimadzu model name:UV 1900,Brand :shimadzu,Display =fully touch screen,Type-portable,size 450x501x244 as per department incharge 180 Supplying of potentiometer ,Range-0 to 1999.9mv,Resolution-1 mv,Repeatability -1mV,Accuracy +1 mv+ digit,Input impedency-10ohms,operating temperature 10 to 50 degree Celsius,Display 1/2 digit 0.5 seven segment LED Display indication,Power-230V+10,50hZ,Dimensions 76x275x170 mm,weihjt 2 kh as per department incharge 181 Supplying of Conductivity meter,LT 26 Deluxe conductivity meter,Product details:Model no-LT-26,Brand -Labtronics,Usage-Laborataty,Display type 3.5 Digit LEDas per department incharge 182 Supplying of Online COD/BOD Detector analyzer warer quality monitoring probe,Measure range-0-200/0-1000mg/l,Resolution -1 mg/l ,Accuracy +5%F.s ,Under pressure-1 bar,Power supply -12-24V DC ,Temperature range 0-45 degree ,Production leve;-IP68 as per department incharge 183 Supplying of melting point appratus,Temperature renge -2 degree above ,Readability 1 degree ,Display -3 Digit LED,Heating rate control-Electronic,Temperatre sensor PT-100as per department incharge 184 Supplying of Ph meter Labrtonics,Range:0-14pH,Resolution:0.01pH,Accuracy:0.01pH(Relative),Temp comp:Automatic wvith temp probe,Buffer:Manuals with keys as per department incharge 185 Supplying of Spectrum 3 FT-IR Spectrometer,Model no.-LI280127,Wave length -11000-30 cm-1 as per department incharge 186 Supplying of Stopwatch NIVIA 600 plastic(Product Specification:Color-Black,Usage/Application-Sports,Time Display 12/24 hour display for user option,Material-Plastic,Dial Shape-OvalMaximum Counting-23 hours 59 minutes 59 secondsas per department incharge 187 Supplying of Digital Bomb Calometer(Specification-Auto Off Automatic,Frequency-50 Hz,Voltage-230-280 V,Operating Time Per Test 10 minutes,Power Source Electric(Automatic) as per department incharge 188 Supplying of Microprocessor viscometer ,Product details: Measuring range-101x105mpa,,Spindles-4 Spildles,Rotor speed(rpm)-6/12/30/60 rotor speed rpm as per department incharge 189 Supplying of Flame photometer,Product details:Application-Laboratory use,industialuse,,weight 705kg ,Curve fit accuracy,Resolution-0.1ppm/meq as per department incharge 190 Supplying ofwater purification system,Resolution-18.2 M ohm cm at 25 degree C,Weight-19.5kg,Frequency-50-60Hz as per department incharge 191 Supplying of Refrigerator of 7.5kg fully Automatic Top Load washing machine (Hard water wash,Grey,5 star,10 years warranty as per department incharge 192 Supplying of water bath ,unstirred water bath s ,Digital info Water bathdigital,18L amb+5 tp 99 degree C includes clear lid and base trayas per department incharge 193 Supplying ofmini rotary shakers 50to 400RPM,features-220/230 V ac,Power supply-50-60Hzas per department incharge 194 Supplying of Magnetic stirrer- capacity 5 litre Spinit Digital Magnetic Stirrer Features-Type of Product-Magnetic stirreras per department incharge 195 Supplying of Digital ultrasonic cleaners (Specification: tank capacity 4 L, ultrasonic power 100W, Heating, Power-100W, time setting 1-99 min, heating temp up to 80 degree, in and out both in ss, with digital timer auto stop of sonication. 230V AC +-10% 50HZ. Tank size 300x150x100mm, overall size 330x180x240mm.supplied with basket and Lid.) as per department incharge 196 Supplying of Calomel electrode (Product Specification:Packaging Type-Box.,Length-120 mmUsage-Electrochemical Study(Laboratory))as per department incharge 197 Supplying of Pt-wire counter electrode (Product Specification Electrode Diameter-0.5 mm,Power Source-10A) as per department incharge 198 Supplying of UV-LAMP Cabinet(Product SpecificationSize/Dimension-15 X 12 X 10 (H) Light Source-3 NOS , SHORT WAVE -254nm-1no, LONG WAVE-365nm, VISIBLE LIGHT,Material-MILD STEEL,Voltage 230 V AC) as per department incharge 199 Supplying of Magnet (Magnet Grade-N48 Shape-Cup & Pot,Material Neodymium,Dimensional Tolerance+-0.05 mm,Plating / Coating-Ni-Cu-Ni Colour-red,Surface Gauss 3000 Gauss,Maximum Working Temperature (Deg. C)-230 Deg. C as per department incharge 200 Supplying of Micro Centrifuge tube(Specification: Usage/ApplicationLaboratory Analyzers,Material,Polypropylene Color-White,Pack Contains--20 Packet / carton & 500 pcs / packet,Shape-Conical,Length-4.1 cm,Inlet Diameter-1.3 cm Capacity2 ml)as per department incharge 201 Supplying of Micropiprtte(10-100uL),(Product Specification Capacity-10 ml,Volume Increment -0.1 microlitre Material-Glass,Autoclavable-Yes)as per department incharge 202 Supplying of Micropiprtte(10-1000uL),( Product Specification Material-Plastic,Capacity-Up to 1000ul,Color-Transparent Usage/application-Chemical Laboratory) as per department incharge 203 Supplying of printer-Black and white print ,scan,copy all in one printer Product Specification Print Speed-Up to 18ppm / 19ppmLaser Printer,Color Output-Black & White,Print Technology LaserjetUsage/Application-Printing,Supported Paper Size-A4 Compatible Operating Systems1,Windows 8,Windows 7,Windows Vista,Windows XP,Windows 2000,Mac OS X 10.4 - 10.8,Linux*3 Print Resolution-Up to 600 x 600DPI,1 200 (Equivalent) x 600DPI,Print Language-UFR II LT Dimension-372 x 371 x 254mm (With the Cassette Opened)Weight(W/O CRG)-7.6kg,Monthly Duty Cycle-8000 Pages Power Consumption 960W(Maximum),First Printout Time7.8s / 7.7s (A4 / LTR),Zoom 50 - 200% in 10% Increments Refill Type Toner Cartridge,Internal Memory 64 MB Printer Language UFR II LT (Host Based),Paper Weight 60 to 163g/m2 (Cassette),Copy Speed Up to 18 / 19Cpm (A4 / LTR) Halftones 256 levels,Copy Resolution 600 x 400 DPI Display 7 - Segment,1 - Digit LED as per department incharge 204 Supplying of printer-colour print ,scan,copy all in one printer (Specification :Functions-Print | Scan | Copy,Technology-Inkjet Color output-Color | B&W,Connectivity-Wireless(Wi-Fi) Usage-For Office ,Paper size-A4,Print speed upto 40 pages/min)as per department incharge 205 Supplying of photocopier branded fast print 50ppm high image resolution superior print quality,fast scan up to 50ppm A4 Monocolouras per department incharge 206 Supplying of LAN.Networking,cabling,switches,Wi-Fi points(10 points in each department) as per department incharge 207 Supplying of installation of Printer (Black and white),Printer( colour),Photocopier and LAN,Networking,Cabling,Switches,Wifi Points as per department incharge 208 Supplying of RS+ TT7519RS,RS75+ comes with 75 diagonal length with 3 GB RAM and 48 GB ROM,Slim Glare ,H7 touch surface hardness,Light weight for easy installation,Media suits for Annotation software Bundled with education apps,Office suits ,Great writing experience,Object recognition-First /palm /fine pen ,Touch points -20 points under andriod ,178 degree viewing angle ,IR Touch 15000 14-01-20241 contrast ratio as per department incharge 209 Supplying of Freightof RS+ TT7519RS,RS75+ comes with 75 diagonal length with 3 GB RAM and 48 GB ROM,Slim Glare ,H7 touch surface hardness,Light weight for easy installation,Media suits for Annotation software Bundled with education apps,Office suits ,Great writing experience,Object recognition-First /palm /fine pen ,Touch points -20 points under andriod ,178 degree viewing angle ,IR Touch 15000 14-01-20241 contrast ratio) as per department incharge 210 Supplying of wall mount (Dimension long:Telescopic Adjustable CCTV camera mounting bracket -Color: Beige Universal Camera Bracket, Heavyduty weatherproof iron bracket fits mostbrands of outdoor camera housing,Iron stand Platsic APPLICATION: Ideal for indoor outdoor dome cameras, Security Camera Mount Bracket, high quality with professional design,more stable and reliable.Hidden hole: Cable can feed thru L bracket tothe housing thus provide cable protection Outdoor and Indoor Use.)as per department incharge 211 Supplying of Camcorder Compact full HD ENG Camera with 20X zoom and 5 axis image stabilization. 20X optical zoom (26.8mm, F/1.8-576MM, F/2.;28.8MM, f/1.-576mm). 5 axis image stabilization. Support formats: full HD50P/60P, AVCHD/MP4;SD card slots 2 35mm film camera equivalent when dynamic IS is turned on with Tripod as per Department Incharge 212 Supplying of Video capture and video capture card (Product Specification:Converter type-USB,Material:Metal,Audio Jack:3.5 mm,HDMI Version:Hdmi-1.4,Audio:44100 AU,Video:Full HD Frame:48000 Resolutions)as per department incharge 213 Supplying of UPS(1KVa)(Product Specification: Type-Online UPS,Capacity-1 kVA,Configuration-1 Phase IN - 1 Phase OUT,Protection-OverVoltage,Form Factor-Tower Model Back Up Time-20- 30 Mins,Frequency-40 ~ 70 Hz (auto-sense) Usage/Application All) as per department incharge 214 Supplying of Studio light-125watt,5 LED BULBS consisting of 25watt bulb(Colour Temperature:5500 kelvin)as per department incharge 215 Supplying of Live streaming software for live streaming or live telecast as per department incharge 216 Supplying of Cables,installation,SSD Card(SAMSUNG VNAND SSD 850 EVO 2.5 250GB SATA III 3-D Vertical Internal Solid State Drive (SSD) MZ-75E250B/AM) as per department incharge 217 Supplying of complete making soundproof class(20*20 feet Room) as per department incharge 218 Supplying of RFID Tags RFID Book Lables(specification: Language ‏ : ‎ English,Simultaneous device usage ‏ : ‎ Unlimited Text-to-Speech ‏ : ‎ Enabled,Screen Reader ‏ : ‎ Supported Enhanced typesetting ‏ : ‎ Enabled,X-Ray ‏ : ‎ Not Enabled,Word Wise ‏ : ‎ Not Enabled) as per department incharge 219 Supplying of Anti theft stickers with the university logo(Polycarbonate 175 Microns Matt Finish) as per department incharge 220 Supplying of Middleware Application Desktop(writing and read tags) as per department incharge 221 Supplying of RFID Staff station or desktop reader (used for Tagging of books and circulation) operations through RFID as per department incharge 222 Supplying of Integration with software and Training of complete RFID System as per department incharge 223 Supplying of Data Encoding,Booking Tagging and Registration per book as per department incharge 224 Supplying of RFID Secuity Gates (2 pedestals - 1 gate),RFID Secuity Gate(Provide Installation Service-Yes,Support-24/7 (Live Reporting Language Support-English) as per department incharge 225 Supplying of Automated book drop box (ntegrated RFID Reader • Approx. 250 Books Receiving Cart (Movable) • Client Software for Checking-in Facility and communicating with LMS with provision for E-mail/SMS confirmation • Has automatic hutch which should open only on valid RFID tags and close once the book has been accepted to prevent the patrons from removing checked in books. • Communication with any LMS Software through SIP2/NCIP protocols • Compliant with internationally recognized standards for RFID based library self-services systems. • Book Drop can display item ID once item is returned. • Enabled with necessary items i.e.: Branded CPU etc. • 15” or higher LCD/LED Touch Screen Monitor. • Ethernet High Speed Receipt Printer (Reputed/Branded) • Customizable Design matching the library aesthetics; Contemporary and attractive. • Design is such that there is not damage to the dropped books. • Library Ethernet network and wireless network compliant. • Optional Features: Fingerprint Scanner, Smart Card Readers etc) as per department incharge 226 Supplying of 5KVA Invertor -online UPS with battery back up 100Mah battery (8 units)(Product Specification,Capacity-1100 Voltage-130V ,Rated Input Power-5 KVA,Display-Digital Type-Square Wave Inverter Country of Origin) as per department incharge 227 Supplying of LAN,Switches,Necessary cabling,casing,power supply port including cables as per department incharge 228 Supplying of Installation charges of RFID Tags,Anti-theft sticker,Middleware Application Desktop,RFID Staff statio,Integration of software,Data incoding books,RFID Secuirty Gates,Automated Book Drop Box,Cabling,Casing,Wiring,Switches,LAN as per department incharge 229 Supplying of Air conditioning 1.8Ton heavy duty AC (minimum 3 star rating,Coil material -copper,Power consumption-1950W,Power Requirement -AC 130-285V, 50Hz) as per department incharge 230 Supplying of Desktop,i5 processor ,7th Generation,500GB HDD,4GB RAM,23.8 INCH LED Backlit Monitor,Full HD IPS Panel(Brand-HP,Dell,Acer) as per department incharge 231 Supplying of Headphone with built in microphone,(Communication-Wired) as per department incharge 232 Supplying of 75 diagonal length with 3 GB RAM and 48 GB ROM ,Slim frame anti glare glass.3M Antiglare ,H7 Touch surface hardness,Light weight for easy installation as per department incharge 233 Supplying of Dedicated server-HPE Proliant DL 380,Gen 10 5218.2.3GHz 16core ,1P-32GB-R P408ianNC 8SFF 800WPS Server,Intel xeon G5218 Kit for DL 380,Gen 10 as per department incharge 234 Supplying of 5.5KVA Inverter with battery backup,Microtek inverter,online UPS ,65Mah battery(16 unit )-Exide as per department incharge 235 Supplying of Freight Transportation Charges of Desktop,Headphone,LAN Switches,4K-OPS,Dedicated server,5.5 KVA Inverter with battery back up and Air conditioner as per department incharge 236 Supplying of 86 Diagonal interactive display,3 GB RAM,48 GB ROM,4K Display Android model,Slim framenAnti glare Glass,H7 Touch Surface hardness ,Light weight for easy installation ,Media Suits for Annotation softwatr bundled with education Apps as per department incharge 237 Supplying of 4k OPS i5,7th Gen,8GB RAM,128 GB SSD as per department incharge 238 Supplying of play mounting including white board & Green board,Material post formed ply,Size 15ft(length)x7ft(ht) with green board for chalk,whiteboard for marker and cupboard as per department incharge 239 Supplying of UPS (1KVa,Phase-Single phase.Back up Time 10-20 min,Frequency-50Hz) as per department incharge 240 Supplying ofTraining and installation of 86 diagonal interactive display,4k-OPS,Play mounting including white board & Green board and UPS of 1KVA as per department incharge 241 Supplying of Digital Podium PTGN 500 Windows 8.1 LCD ,Electronic Lectern,On site OEM Warranty in 3 yearsas per department incharge 242 Supplying of PA System sound system with amplifier 350 watt ,30 watt speaker (4 nos) as per department incharge 243 Supplying of wireless mic Dual channel cordless microphone as per department incharge 244 Supplying ofTraining and installation of Digital Podium,86 Diagonal interactive display (4k display),4K-OPS,Play mounting including white board and green board,5KVA invertor,PA System and wireless mic as per department incharge 245 Supplying of Desktop :- 1).i5 Processor, 7th Generation, 500GB HDD, 4GB RAM, 2).23.8 inch. LED backlit Monitor Full HD IPS Panelas per Department Incharge 246 Supplying of 55 LED Display for CCTV Branded LED Display as per department incharge 247 Supplying of CCTV Camera IP based CCTV camera,2 TB Space with NVR with necessary accessories as per department incharge 248 Supplying of Stagmometer as per Department Incharge 249 Supplying ofViscometer as per Department Incharge 250 Supplying of Beaker-50ml as per Department Incharge 251 Supplying of Beaker-100ml as per Department Incharge 252 Supplying of Beaker-250ml as per Department Incharge 253 Supplying of Beaker-500ml as per Department Incharge 254 Supplying of Beaker-1000ml as per Department Incharge 255 Supplying of Buchner Funnel 3 as per Department Incharge 256 Supplying of Buchner Funnel 6as per Department Incharge 257 Supplying of Burette-50ml as per Department Incharge 258 Supplying of Chromatography column 1x18 with stop cock as per Department Incharge 259 Supplying of Conical flask-100ml as per Department Incharge 260 Supplying of Conical flask-250ml as per Department Incharge 261 Supplying of Conical flask-500ml as per Department Incharge 262 Supplying of Conical flask-1000ml as per Department Incharge 263 Supplying of Flat Bottomflask-500ml(Round) B-24 socket as per Department Incharge 264 Supplying of Round bottom flask-50ml Joint B-24 as per Department Incharge 265 Supplying of Round bottom flask-100ml Joint B-24 as per Department Incharge 266 Supplying of 3 neck RB flask B-29,B-19.as per Department Incharge 267 Supplying of Condenser Spiral B-24 and, B-19 as per Department Incharge 268 Supplying of Condenser Spiral B-24 and, B-24 as per Department Incharge 269 Supplying of T-type tube as per Department Incharge 270 Supplying of Rubber Cock No. 10 as per Department Incharge 271 Supplying of Specific Gravity hydrometer 800-1000 as per Department Incharge 272 Supplying of Specific Gravity hydrometer 100-1200 as per Department Incharge 273 Supplying of Universal hydrometer 1000-2000 as per Department Incharge 274 Supplying of Measuring Cylinder-10ml as per Department Incharge 275 Supplying of Measuring Cylinder-50ml as per Department Incharge 276 Supplying of Measuring Cylinder-100ml as per Department Incharge 277 Supplying of Measuring Cylinder-500ml as per Department Incharge 278 Supplying of Measuring Cylinder-1000ml as per Department Incharge 279 Supplying of Measuring Cylinder-2000ml as per Department Incharge 280 Supplying of Measuring flask-100ml as per Department Incharge 281 Supplying of Measuring flask-500ml as per Department Incharge 282 Supplying of Measuring flask-1000ml as per Department Incharge 283 Supplying of Pipette-0.5ml as per Department Incharge 284 Supplying of Pipette-2ml as per Department Incharge 285 Supplying of Pipette-5ml as per Department Incharge 286 Supplying of Pipette-10ml as per Department Incharge 287 Supplying of Pipette-25ml as per Department Incharge 288 Supplying of Separating Funnel-250ml B-24/B-24 as per Department Incharge 289 Supplying of Spatula Flat Spoon 6as per Department Incharge 290 Supplying of Spatula Flat Spoon 5as per Department Incharge 291 Supplying of Stop Cork 2wayas per Department Incharge 292 Supplying of Silica crucible-15ml without Lid as per Department Incharge 293 Supplying of Silica crucible-25ml without Lid as per Department Incharge 294 Supplying of Stalagmometer Straight Graduated as per Department Incharge 295 Supplying of Chemical thermometer 10c-110c as per Department Incharge 296 Supplying of Chemical thermometer 0c-250c as per Department Incharge 297 Supplying of Tiration flask-100ml as per Department Incharge 298 Supplying of Tiration flask-250ml as per Department Incharge 299 Supplying of Tongs crucible S.S.8 as per Department Incharge 300 Supplying of Test tube holder as per Department Incharge 301 Supplying of Filter Flask-500ml as per Department Incharge 302 Supplying of Filter Flask-1000ml as per Department Incharge 303 Supplying of Watch glass 3 as per Department Incharge 304 Supplying of Watch glass 4 as per Department Incharge 305 Supplying of Watch glass 6 as per Department Incharge 306 Supplying of Wire gauge150x150mm as per Department Incharge 307 Supplying of Tripod stand 8 as per Department Incharge 308 Supplying of boiling Test tube 1x8as per Department Incharge 309 Supplying of boiling Test tube 2x8as per Department Incharge 310 Supplying of Reagent Stickers 2x1 as per Department Incharge 311 Supplying of Ordinary Filter paper as per Department Incharge 312 Supplying of Reagent bottles-250mlas per Department Incharge 313 Supplying of Rubber cork as per Department Incharge 314 Supplying of Rubber tube 6mm as per Department Incharge 315 Supplying of Solid Reagent bottle-125mlas per Department Incharge 316 Supplying of Stopwatch plastic body as per Department Incharge 317 Supplying of Test tube stand 12 holes as per Department Incharge 318 Supplying of Thermometer 360 as per Department Incharge 319 Supplying of Test Tube 6mmx15cmas per Department Incharge 320 Supplying of Test Tube 10mmx10cm as per Department Incharge 321 Supplying of China dish 3 as per Department Incharge 322 Supplying of China dish 4 as per Department Incharge 323 Supplying of Brushes for Test Tube as per Department Incharge 324 Supplying of Brushes for Burette as per Department Incharge 325 Supplying of Brushes for Conical flask as per Department Incharge 326 Supplying of LPG gas burner as per Department Incharge 327 Supplying of Condenser Coil 12 as per Department Incharge 328 Supplying of Receiving adopter with vacuum outlet as per Department Incharge 329 Supplying of Plastic Wash bottle-500mlas per Department Incharge 330 Supplying of Pastel and Mortar 3 as per Department Incharge 331 Supplying of Pastel and Mortar 4 as per Department Incharge 332 Supplying of Pastel and Mortar 6 as per Department Incharge 333 Supplying of China Clay 2 as per Department Incharge 334 Supplying of China Clay 3 as per Department Incharge 335 Supplying of China Clay 4 as per Department Incharge 336 Supplying of Petri Dish 3(Borosil) as per Department Incharge 337 Supplying of Petri Dish 4(Borosil) as per Department Incharge 338 Supplying of Distillation Set-Complete flask-500ml as per Department Incharge 339 Supplying of Distillation Set-Complete flask-1000ml as per Department Incharge 340 Supplying of Thermometer Pocket B-14 as per Department Incharge 341 Supplying of Sintered Glass Funnel-25ml as per Department Incharge 342 Supplying of Air Condenser 12 as per Department Incharge 343 Supplying of Burette Stand with Clamp as per Department Incharge 344 Supplying of Cork borer as per Department Incharge 345 Supplying of Capillary Tube for melting point as per Department Incharge 346 Supplying of Dessicators 6 as per Department Incharge 347 Supplying of Dessicators 8 as per Department Incharge 348 Supplying of Dropper with Rubber teats 6 as per Department Incharge 349 Supplying of Dropper 4(Borosilicate glass) as per Department Incharge 350 Supplying of Dropping bottle-125ml as per Department Incharge 351 Supplying of Funnel Stand as per Department Incharge 352 Supplying of Fusion Tubeas per Department Incharge 353 Supplying of Glass Rod as per Department Incharge 354 Supplying of Glass Tube as per Department Incharge 355 Supplying of Stopwatch Steel body as per Department Incharge 356 Supplying of Magnetic Stirrer as per Department Incharge 357 Supplying of Rubber Gloves as per Department Incharge 358 Supplying of Reagent as per Department Incharge 359 Supplying of Sandbath as per Department Incharge 360 Supplying of Tissue Paper(Local made) as per Department Incharge 361 Supplying of Double Beam PC Microprocessor UV-VIS Spectrophotomet erMake:Systroni cs Model: 2202 PC Based Double Beam Automatic source optimization ,Base line calibration & Cell optimization 200 - 1100 nm Range2. 0 nm Bandwidth%T. Abs. Conc . (K factor. Multi standard ). Multi component measuring modesSingle Wave length, Multi Wave length Scan (with multi scan facility). Time Scan. Kinetic scan operating modes Automatic 5 position sample changer Single Position 50 /100 mm Cuvette Holder (Optional) as per Department incharge 362 Supplying of Refrigerated Centrifuge,(Specification:Speed:- 20000 Max.,RCF:- 37570 Max.,Lowest Temp:- -8,Noise:- <-60db)as per Department incharge 363 Supplying of Refrigerated Centrifuge Essential accessories Required:. With angle Heads (with polypropylene tubes)Model- R-248M 24xl.5 ml as per Department incharge 364 Supplying of Refrigerated Centrifuge 2. Voltage stabilizer:- 03 KW Servo controlled Voltage Stabilizer, input 170 volts to 260 volts, output 220 volts to 240volts as per Department incharge 365 Supplying of PCR machine(Specification- Well block, Gradient, temp. range 4° - 99-irC, memory capacity 10000 protocols , display 7inch,volume capacity I 0- 100 μL , preloaded protocol, temperature accuracy ±0.2°C@99°C, with PCR wizard as per Department incharge 366 Supplying of SOS PAGE unit and Western Blot apparatus along with power bank -Mini-TBC electroph_oretic transfer cell, includes: Mini 01P-4 cell tank and lid with cables, buffer, Mini transfer module, gel holder cassettes, 4 fiber pads, cooling units, instructions, Western blot unit, compatible power bank as per Department incharge 367 Supplying of pH Meter With electrode(Type of PH Mater - Portable,Ph Range:0-14,Resolution-0.01pH,compensation-0 to 80 degree celsius) as per Department incharge 368 Supplying of Deep fridge(It is used to store chemicals and preserve samples at very low sub-zero temperatures or below)as per Department incharge 369 Supplying of Autoclave (Vertical)Size- 400 x 600mm ,;Capacity- 75Ltr as per Department incharge 370 Supplying of Hot air oven (Sterilization) as per Department incharge 371 Supplying of Incubator Shaker-Growth and enumeration of microbes (Broth cultures) as per Department incharge 372 Supplying of Horizontal Laminar air flow(Sterile environment Size 4X2)as per Department incharge 373 Supplying of Horizontal Agarose gel electrophoresis unit with gel caster and Power pack Separation of macromoleculeas per Department incharge 374 Supplying of Vortex mixture-To mix content of test tubes and microfuge tubes. as per Department incharge 375 Supplying of Ultrapure Water Purification System:MiliQ Water For distill wateras per Department incharge 376 Supplying of Micropipets - 0.1μL-2.5μL 0.5μL-10.0μL 10.0μL-l00μL 20.0μL-200μL l00μL-l000μL as per Department incharge 377 Supplying of Quebec Colony Counter -Count the microbial colonies as per Department incharge 378 Supplying of Light Microscope (General) 10X,20x, 45x, l00x Visualize microorganisms as per Department incharge 379 Supplying of Bifocal microscope with illuminators, Camera attachment and computer Visualize microorganisms and microgrphy as per Department incharge 380 Supplying of Magnetic stirwith Hotplate and magnetic beads To stir the liquids , preparation of solution as per Department incharge 381 Supplying of Heating mantle For heating round bottomed flask/distillation flask as per Department incharge 382 Supplying of Microwave oven To heat liquids instead of flaming. Samsung/ LG 20 Ltrs as per Department incharge 383 Supplying of Glass Dessicators Used for dessication as per Department incharge 384 Supplying of Fluorescence microscope A fluorescence microscope is an optical Microscope that uses fluorescence and phosphore scence instead of,or in addition to, reflection and absorption to study properties of organic or inorganic substances as per Department incharge 385 Supplying of Electronic Analytical Balance It is used to weigh small quantities of chemicals and samples precisely and quickly. Readability- 1 mg (0.001 g) Cap.- 420gm as per Department incharge 386 Supplying of Electronic Top pan Balance- Readability- 0.1 g Cap.- 2 kg.as per Department incharge 387 Supplying of Double Distillation Unit ,.Approx output: 2 Lit/hrs Wattage:3.3 .KW With safety Cutoff Device Water Stills are carefully designed to produce high purity pyrogen free distiiied water. The water still comprises ofborosilicates glass horizontal typeboiler, coil condenser, constant level device, silica sheathed heaters, along with stand and clamps. All parts are replaceable. pH/conductivity:6-7 / 1-2 μSiem forsingle, 6-7/0.8-lμS/cm for double distilled water as per department incharge 388 Supplying of Microtome-5286(Product Specification Minimum Setting Value-0.5 um,Object Feed-28 mm,Vertical Stroke-60 mm,Specimen Orientation X and Y Axis Universal 8 Degree Trimming Thickness Range-1 um-100 um Operation-Automatic. (Motorized Feed & sectioning and Emergency Stop Provided),Sectioning Speed-0-400 mm/sec.,Specimen-Orientation Z Axis-Upto 360 Degree,Retraction Value-Adjustable Max Specimen Size-50 x 50 mm,Section Thickness Range-0.5 um-60 um)Senior rotary microtome as per Department incharge 389 Supplying of Cryostat -(Product Specification Section Thickness Range-0.5 Micron to 100 Micron (with the increment of 0.5 Micron, 1 Micron, 2 Micron, 5 Micron) Power Supply-220v,Dimension-750mm x 750mm x 950mm (approx) Weight -123 kg (approx),Remote Control-Optional,Sectioning Mode-Single step mode/ Continuous mode Hand Wheel Control-Feather Touch Keypad/ Foot Switch/ Remote Control (optional),Sterilization-U.V-C Sterilization,Cooling down time Up to -30 DegreeC-2 Hour 30 Min Specimen Retraction setting Range-5 Micron to 100 Micron (with increment of 5 Micron),Compressor-Dual Compressor,Cryo Chamber Temp. Adjustable -1 DegreeC to -30 DegreeC Block Holder Head Temperature-Adjustable -1 DegreeC to -35 DegreeC Illumination-LED Lamp)Ultimate usico fully automatic cryostat as per Department incharge 390 Supplying of ELISA -Vet scientific(Specification-Product Specification Automation-Semi Automatic,Assays Performed-ELISAs, Immuno Assays Plate Format-96 well,Optical System Filter-based Detection Method-Absorbance,Number Of User Programs 42 Storage-100000 Results,Filter Positions-8 Display Type-Touch Screen Packaging Type-EXPORT QUALITY,Testing Speed-3 second Type Of Filter 405,450,492, 630,Power Source-115/230 V AC, 50Hz,Weight-9 Kg,Is It Portable-Non Portable, sample Type-Serum, Plasma, Urine, CSF, Whole Blood,sample Volume Range-10-100 Interface-RS232/ USB) as per Department incharge 391 Supplying of Calorimeter -A VI Digital (A VI Scientific,Frequrcy:50Hz,Voltage:230-280V,operating time per test-10 min) as per Department incharge 392 Supplying of HaemometerSahli type-Microsidd (Specification:Amber coloured glass bottle -1 No.,Glass Stirrer-1 No.,Dropper with teat -1 No.,Cleaning Brush -1 No.,Spare latex tubing one meter -1 No.Round tube haemoglobinometer) as per Department incharge 393 Supplying of Anti - theft Sticker with the University logo as per Department incharge 394 Supplying of Middleware Application Desktop(Write and Read Tags) as per Department incharge 395 Supplying of RFID Staff Station or desktop reader (Used for tagging of books and circulation {lssue/Return) operations through RFID) as per Department incharge 396 Supplying of Integration with Software and Training of Complete RFID System as per Department incharge 397 Supplying of RFIDSecurityGates (2 pedestals-1 gate) RFID Security Gate (Single Lane) as per Department incharge 398 Supplying of Automated Book drop Box as per Department incharge 399 Supplying ofCabling. Casing. Wiring , Switches as per Department incharge 400 Supplying of Freight Transportation of Miidle ware Application Desktop,RFID STAFF Station,Integration with software training,Automated Drop box ,Cabling,Casing,Wiring,Switches as per Department incharge 401 Supplying of LAN . Switches, Necessary Cabling, Casing , Power Supply port including cables as per Department incharge 402 Supplying of Dedicated serverGHZ 16 core 1P-32GB -RP408ia -NC8SFF800WPS Serverintel Xeon -G5218 Kit for DL 380 GEN-10-HPE 32GB 2RX4 PC-4 2933YR Smart kit ,HPE DL38x Gen 10-12 Gb SAS Expande,HPE DL 380Gen 10 Box 1/2 Cage Bkpin kit ,HPE 24TB SAS 12G 10K SFF SC 512eDS HDD .HPE 800 WFS Ht Plg LHPwr Sply kit,HPE 3 Year Fiundation care 24x7 DL 380 Gen 10 Serviceas per Department incharge 403 Supplying of RS 86+_TB619RS, 3GB RAM and 48 GB ROM,4K Display Android model,3 GB RAM And 48 GB ROM,slim frame,Anti Glare Glass,3M Anti glare H7 Anti touch surface hardness lightweight for easy installation,Media suits for Annotation,Software bundled with education apps,Office suits,Great writing experience,Object recognition -First pal,/Fine pen ,Touch Points-20 points under window and 10 points under android,178 degree viewing angle IR ,Touch 15000,1 contrast ratio,4 MS Response time 50000 hours life,Reduce clutter and bring efficiency for the faculty,Remote control,15 wattX2 speaker,Android 8.0,Newline cast,Display management,Newline broadcast including installation and Trainingas per Department incharge 404 Supplying of Deep Fridgeas(2 in 1 Converti Freezer & Cooler Corrosion Resistant Cooling Coil & PPGI for inner & outer body Heavy Duty Compressor & Tropicalised Design Approximately 14% Higher Net Capacity compared to competition Sleek Design with heavy duty performance) per Department Incharge 405 Supplying of Autoclave (Horizontal,Height X Dia: 450mm x 250mm Height x Dia: 18Inch x 10Inch,Capacity: 22 Ltr,Load: 2.0 KW) as per Department Incharge 406 Supplying of Autoclave (Vertical): size- 400x600mm, Capacity- 75Ltr as per Department Incharge 407 Supplying of Hot air oven(Standard double wall fabrication. Inner chamber made of highly polished stainless steel sheet. Exterior fabricated out of thick mild steel sheet duly finished in stove enamel off-white paint or paste mat finish colour combinations.Nichrome wire heating elements -provided on three sides attain quick and uniform heating in range of 50c to 250c + 1c controlled by capillary type thermostat.Inner Chamber Size 18x18x18 inch. made of Stainless Steel) : any Standard make as per Department Incharge 408 Supplying of Bacteriological incubator(Item Weight ‎10 kg Product Dimensions-30 x 30 x 30 cm; 10 Kilograms,Item model number-12X12,Item Height-30 Centimeters Item Width-30 Centimeters) as per Department Incharge 409 Supplying of Bacteriological shaking incubator as per Department Incharge 410 Supplying of BOD incubator as per Department Incharge 411 Supplying of Laminar air flow any Standard company as per Department Incharge 412 Supplying of Micropipettes with microtips :(1.0uL-10.0uL, 10.0uL-100uL, 100uL-1000uL, 20uL-200uL): A. Prime Variable Pipette, B. Fully Autoclaveable Variable Vol. Pipetteas per Department Incharge 413 Supplying of Colorimeters with cuvettes any Standard company as per Department Incharge 414 Supplying of Western Blot apparatus, as per Department Incharge 415 Supplying of Powerpack with wiresas per Department Incharge 416 Supplying of Homogeniser as per Department Incharge 417 Supplying of PCR machine Block Formats 96x0.2ml(A),54x0.5ml(B), 96x0.2ml +77x05ml©, 384well(D) Size(WxDxH,mm)-380x270x250 as per Department Incharge 418 Supplying of UV Transilluminator/UV chamber UV source: 365nm Wave Length Viewing area: 24x14cm Anti Slip rubber foot provided for base as per Department Incharge 419 Supplying of CO2 incubator as per Department Incharge 420 Supplying of pH meter and buffers: A.pH meter B. pH buffers as per Department Incharge 421 Supplying of Water bath (any Standard company ) as per Department Incharge 422 Supplying of Fume Hood: size- 3x3x2 wooden with Granite working area as per Department Incharge 423 Supplying of Soxlet apparatus with heating mantle and distillation set up as per Department Incharge 424 Supplying of Kjeldahl Apparatus as per Department Incharge 425 Supplying of Ultrapure Water Purification System: MiliQ water as per Department Incharge 426 Supplying of Quebee Colony Counter as per Department Incharge 427 Supplying of Light Microscope (general) 25x, 45x, 100x s as per Department Incharge 428 Supplying of Bifocal microscope with illuminators as per Department Incharge 429 Supplying of Magnetic stirrer with magnetic beads(any Standard company )as per Department Incharge 430 Supplying of Magnetic stirrer with hot plate (Remi) as per Department Incharge 431 Supplying of Heating mantleas per Department Incharge 432 Supplying of Microwave oven ((20Ltr) as per Department Incharge 433 Supplying of Glass Dessicators as per Department Incharge 434 Supplying of Computer : Core i9, 7th Gen. 20 LED Monitor, 4GB DDV, 1TB HDD, DV writer HP/Dell as per Department Incharge 435 Supplying of Culture room: Tissue culture Rack fitted with 16 tubes, 8 bulbs, 4UV & Timer as per Department Incharge 436 Supplying of Electronic Analytical Balance:- Readability- 1mg(0.001g) Cap.-420gm as per Department Incharge 437 Supplying of ElectronicTop-pan Balance:-Readability- 0.1g Cap- 2kgas per Department Incharge 438 Supplying of Electroporator:- as per Department Incharge 439 Supplying of Fermenter(7.5L)(any Standard company )as per Department Incharge 440 Supplying of Fluorescence Microscopeas per Department Incharge 441 Supplying of Hot air oven universalas per Department Incharge 442 Supplying of Distillation Unit as per Department Incharge 443 Supplying of Membrane filter assembly 5000 mlas per Department Incharge 444 Supplying of Fluorimeter as per Department Incharge 445 Supplying of Homogeniser: Remi model- RQT-127 A/D High speed homogenizer, with 1/8 HP Motor, Homogenizer Working Volume [H2O] 0.1-50ml (Dispersing shaft DS-160/5) WEIGHT 0.6KG Dimension[LxWxH] 46mmx55mmx230 operating environment 0-40degre, 85% rel. humidity as per Department Incharge 446 Supplying of ELISA reader and Microtitre plates: ELISA Wavelength range 400nm-800nm Accuracy- +-1% at 1.0OD, 450nm Dimension 450x350x197mm as per Department Incharge 447 Supplying of Liminar air flow : 4x2x2 feet, stainless steel as per Department Incharge 448 Supplying of Gel Documentationd system as per Department Incharge 449 Supplying of 5 KVA Inverter with Battery Backup. Microtek inverter, online UPS 65Mah Battery (16 units) -Exide as per Department Incharge 450 Supplying of 12V/26AH- Batteryas per Department Incharge 451 Supplying of Headphone with built in microphone (Brand) as per Department Incharge 452 Supplying of Furniture:- Computer Table & Chairs & Table- Chair for lab. Instructor and student (50 students per batch) as per Department Incharge 453 Supplying of Network:- LAN, Switches, Cabling, Casing Power Supply Port including Cables as per Department Incharge 454 Supplying of 5.5 KVA Inverter with Battery Backup. Microtek inverter, online UPS 65Mah Battery (16 units) -Exide as per Department Incharge 455 Supplying of RS86+ TT8619RS 3 GB RAM, 48 GB ROM 4K Display, Android Model Slim Frame, Anti-Glare Glass, 3M Anti-Glare, H7 touch surface hardness, Light weight for easy installation. Media Suits for Annotation Software. Bundle with Education Apps. Office Suits. Great Writing Experience. Object Recognition- Fist/Palm/Fine Pen, Touch Points-20 points under Android. 178 Degree viewing Angle, IR Touch. 15000:1 contrast ratio, 4MS Response Time, 50000 Hours life. Reduce cluster and bring efficiency for the faculty. Remote control, 15 watts x 2 speaker. Android 8.0, Newline Cast, Display Managemen, Newline Broadcast Including Installation and Training. as per Department Incharge 456 Supplying ofpH meter(Digital) :- pH range: 0-14, Temperature Range: 0.0 to 100 C (Manual Compensation) as per Department Incharge 457 Supplying ofNoise Level meter:- Auto/Manual ranging from 30 to 130dB in 6 ranges as per Department Incharge 458 Supplying ofWater analysis Kit:- They include; alkalinity, chloride, hardness, iron, and sulphate as per Department Incharge 459 Supplying ofHigh volume sampler:- 1)PM-2.5- Designed to meet International Standards for High volume air Sampling of PM2.5 particulates. 2)PM-10-U.S EPA FRM Designed for the determination of suspended of PM-10 particulates concentrations. (RFPS-1287-063) 3)TSP- Designed to meet U.S EPA reference method for determination of total suspended particulates(TSP) concentration as perDepartment Incharge 460 Supplying ofSoil testing kit (mrinda parikshan kit) : Use for micro and macro nutrients as per Department Incharge 461 Supplying ofSeive plate with shaker : 5mm,1mm,2mm) as per Department Incharge 462 Supplying ofUV/Visible spectrophotometer:- Spectral bandwidth 1 nm (190 to1100nm , Lamp Type 20-W halogen lamp and deuterium lamp as per Department Incharge 463 Supplying ofAutoclave : 10-15 litre Steam Sterilizer as per Department Incharge 464 Supplying ofLaminar hood (Horizantal) : Horizontal air flow cabinet, filter air blow across the work zone in horizontal direction. This constant flow of air provides material and product protection as per Department Incharge 465 Supplying ofHot plate(pic):-Temperature range: 350 C as per Department Incharge 466 Supplying ofShakeer incubator Compact Bench top shaker with temperature control range from Ambient +50C to 600C. Tray dimension : 420x420 , Speed 50-350 rpm with accuracy of +/- 2rpm as per Department Incharge 467 Supplying ofMuffle Furnaces (15x125x250)cm: Temperature upto 35C to 1400C as per Department Incharge 468 Supplying of Analytical Balances:Capacity 220gram as per Department Incharge 469 Supplying ofDigester : 1) vessel size : Dia 39 mm (Aprox.); Volume 160ml 2)Temperature : upto 200degC as per Department Incharge 470 Supplying ofDouble distilled water plant: Model- Vertical:- Distlled Water Output Capacity-2.5 Litres/Hours, Distillate water quality as per Department Incharge 471 Supplying ofOven:- Dry ovens- 30 to 1000 litre capacity. as per Department Incharge 472 Supplying of B.O.D Incubator: Volume 68 Litre as per Department Incharge 473 Supplying ofMagnus Microscope:- Magnification 4x,10x,40x, and 100x as per Department Incharge 474 Supplying ofDesiccators:- Contain: Silica Gel dimension;12x12 in (30.5x30.5 cm),Material Glass as per Department Incharge 475 Supplying ofRichter scale hardness tester Portable Rockwell/brinell vickers Hardness Testing Instrument Mold metal hardness meter display:-parameter- HRC Display Type, Digital Model Name/Number- ATedigiHR, Accuracy- 0.1 HRC Dimensions of Machine base (approx.) 150x425 mm as per Department Incharge 476 Supplying ofProctor Penetrometer: Proctor Penetrometer- Complete with set of needle points Weight, 2 kg as per Department Incharge 477 Supplying ofGas Chromatography Retention time repeatability-< 0.008% or 0.0008 min Area rpeatability -<1% RSD, using 2ng tetradecane as per Department Incharge 478 Supplying of Atomic Absorption Spectrometry(AAS):- aa-7000 SERIES OF Atomic Absorption Spectrophotometers features high- sensitivity analysis as per Department Incharge 479 Supplying ofWavelength range; 400 to710nm Wavelength selection: 8 in-built gelatin filters: 430,470,490,520,540,580,600 and 710 nm Measurement ranges; 0-100%T, 0-1.50Abs, 0.1 to 1000 Concentration. Resolution: 1%T, 0.01Abs, 0.1 to 1 Concentration as per Department Incharge 480 Supplying of Laptops(of Specification:Processor Corei5,RAM:4GB,Hard drive:500GB ,Screen size:12 inch):as per Department Incharge 481 Supplying of Desktops: i7 3rd Gen, 1TB HDD, 4GB RAM, Windos 10, MS office, Graphics card as per Department Incharge 482 Supplying of Xerox Machine(Product Specification:Functions Multi-Function:Supported Paper Size-A3,Supported OS-all,Color Output-Black & White,Number Of Trays-4,Item Color-white and blue Print Speed-up to 35 ppm,Weight 129 kg,Print Technology-Laser Warm-Up Time, As fast as 11 seconds (black and white) Duty Cycle-WorkCentre 5335: Up to 150,000 pages / month Resolution-200 x 1200 dpi) as per Department Incharge 483 Supplying of Air Conditioning:-1.5 Ton heavy duty AC (mimimum 3 Star rating) as per Department Incharge 484 Supplying of Luminous Cruze 3.5KVA Inverter with RC 18000 Battery (4 Batteries) as per Department Incharge 485 Supplying of Projector(Special Feature-portable,Connectivity Technology,Bluetooth, Wi-Fi, USB, HDMI,Display resolution 1920 x 1080,Display Type-LED) as per Department Incharge 486 Supplying of Godrej Lecture Hall Furniture as per Department Incharge 487 Supplying of Electronic Podium(Speaker type-Tweeter,Auxillary,wireless,floor standing) as per Department Incharge 488 Supplying of Smart board (Screen size-11 inches,Connecting technology-Wifi,Multimedia)as per Department Incharge 489 Supplying of Black board( Melamine Writing Surface (Chalk), Paper Honeycomb Core, 6063-T6 Alloy Aluminium Frame & Virgin ABS CornersMelamine Writing Surface (Chalk), Paper Honeycomb Core, 6063-T6 Alloy Aluminium Frame & Virgin ABS Corners) as per Department Incharge 490 Supplying of Glassware rack as per Department Incharge 491 Supplying of installation of Air conditioner,Luminous Cruze,Projector,Lecture Hall Furniture,Electronic podium,Smart board and black board as per Department Incharge 492 Supplying of Inductively coupled Plasma - Optical Emission Spectrometer with CID detector technology for multi-element analysis of geological petrogical etc. samples in ppb level as per Department Incharge 493 Supplying of Suppressed ion analysis system for anion and cation analysis in water, wastewater, environmental samples and also upgradable to combustion for determination of corrosive halogens and sulfur in Petrochemicals, gaseous samples, solid samples, and complex samples as per Department Incharge 494 Supplying of CHNS/O for the analysis of Carbon, Hydrogen, Nitrogen, Sulfur and Carbon in organic matrices, soil, feed , plant samples, petroleum products, Coal, Coke, Biomass & Liquid Fuels as per Department Incharge 495 Supplying of Gas Analyzers for hydrocarbon and permanent gas analysis as per Department Incharge 496 Supplying of Benchotop XRD as per Department Incharge 497 Supplying of XRF Spectrometer as per Department Incharge 498 Supplying of Refrigereted Centifuge MakE-REMI, Model-C24 PLUS :- Max. Speed:20000, Max. RCF:3757, Max. Lowest Temp.:8, Noise:60db. Essential accessories Required: 01. Withangle Heads (with polypropulene tubes) Model-R-248M24x1.5ml 2)Voltage stabilizer:-03KW Servocontrolled Voltage Stabilizer, input 170volts to 260volts, output 220 to 240volts as per Department Incharge 499 Supplying of pH Meter compatible poer bank Make: REMI :- With eletrode as per Department Incharge 500 Supplying of Bench top Centrifuge Make: Tarson, : - SPINWIN MC-001 6 places Rotor for 1.5 ml tubeas per Department Incharge 501 Supplying of Deep Fridge: It is used to store chemicals and preserve samples at very low sub-zero tempertures or below as per Department Incharge 502 Supplying of Autoclave(Vertical) : size- 400x600mm capacity- 75Ltr as per Department Incharge 503 Supplying of Hot air oven : Sterilization as per Department Incharge 504 Supplying of Incubator Shaker: Growth and enumeration of microbes(Broth Cultures) as per Department Incharge 505 Supplying of Horizontal Laminar air flow:- Sterile environment size 4x2as per Department Incharge 506 Supplying of Ultrapure Water Purification System: MiliQ Water : for distil water as per Department Incharge 507 Supplying of Micropipets (Ependroff): 0.1uL-2.5uL, 0.5uL-10uL, 10.0uL-100uL, 100uL-1000uL each oo these 1pcs as per Department Incharge 508 Supplying of Light Microscope (general)10X, 20X, 45X, 100X, : Visualize microorganisms as per Department Incharge 509 Supplying of Bifocalcal Microscope with illuminators, Camera Attachment and comput: Visuallize microorganisms and micrography as per Department Incharge 510 Supplying of Magnetic stir with Hotplate and magnetic bead as per Department Incharge 511 Supplying of Heatingmant; for heatinground bottomed flask/distillation flask as per Department Incharge 512 Supplying of Microwave oven: To heat liquids instead of flaming. 20Ltrs as per Department Incharge 513 Supplying of kydroPro 100 handeld multiparameter water quality analiser: Turbedityas per Department Incharge 514 Supplying of Petrological Microscope: Study of Optical minrology as per Department Incharge 515 Supplying of Ore petrological microscope: Study of ore petrology as per Department Incharge 516 Supplying of Miscellaneous instruments as per Department Incharge 517 Supplying of glassware as per Department Incharge 518 Supplying of chemical as per Department Incharge 519 Supplying of Arc GIS(Latest) as per Department Incharge 520 Supplying of GCD Toolkits as per Department Incharge 521 Supplying of SURPAC Software as per Department Incharge 522 Supplying of Intergraph Edu Kit [GIS+RS] Version 2020 or latest(Software content as per list), 5 users for Erdas imagine Professional and 5 users for Geomedia professional Software as per Department Incharge 523 Supplying of Interactive Flat Panel as per Department Incharge 524 Supplying of 2 Virtual Class Room including capture, recording and streaming online, 1 Servers one per 05 classrooms per Department Incharge 525 Supplying of N-computing for smart classrooms including servers and clients as per Department Incharge 526 Supplying of Tagging of documents(books/hard-bound journals/CDs/technical films etc)in RFID Technology as per Department Incharge 527 Supplying of Sofwares, Server Machines, Air-Conditioning Systems,Xerox Machines, Lamination Machines, Binding Machines, Furniture/Furnishing, Computers, Printers etc as per Department Incharge 528 Supplying of Digital Podium, PTGN 500, Window & 1 LCD, Elecronic Lectern, on site OEM. Warranty 3years, 3GB RAM,4GB ROM as per Department Incharge 529 Supplying of Air Conditioning:-1.8 Ton heavy duty AC (mimimum 3 Star rating) as per Department Incharge 530 Supplying of Black/ White,Printer:- scan-copy all in printer- Branded as per Department Incharge 531 Supplying of CCTV set for floor: 55 LRD display for CCTV. CCTV Camera-1 P based CCTV camera 2TB space with NVR with necessary accessories as per Department Incharge 532 Supplying of 5KVA Inverter online UPS with battery backup 100Mah battery(8 units) as per Department Incharge 533 Supplying of Electrophoresis Apparatus as per Department Incharge 534 Supplying of Bacteriological Incubator as per Department Incharge 535 Supplying of Autoclave as per Department Incharge 536 Supplying of Centrifuge as per Department Incharge 537 Supplying of Rotar Head as per Department Incharge 538 Supplying of Rotar Head 25 as per Department Incharge 539 Supplying of Gel documentation system as per Department Incharge 540 Supplying of Spectrophotometers as per Department Incharge 541 Supplying of compoud Microscope as per Department Incharge 542 Supplying of Trinocular Microscope with camera as per Department Incharge 543 Supplying of Semi-Automated Microtonne as per Department Incharge 544 Supplying of DNA Sequencer as per Department Incharge 545 Supplying of Spectrophotometer as per Department Incharge 546 Supplying of Laminar air flow chamber as per Department Incharge 547 Supplying of Tissue culture rack as per Department Incharge 548 Supplying of PCR Apparatus as per Department Incharge 549 Supplying of Liquid nitrogen cylinder as per Department Incharge 550 Supplying of TLC apparatus kit as per Department Incharge 551 Supplying of TLC Visualizer/documentation as per Department Incharge 552 Supplying of HPLC System as per Department Incharge 553 Supplying of Scientific vortex mixer as per Department Incharge 554 Supplying of Soil Thermometer as per Department Incharge 555 Supplying of Scientific Digital Balance as per Department Incharge 556 Supplying Equipments for workshop,Seminar & Excrusion as per Department Incharge 557 Supplying Equipments for Non-Recurring(Research Equipment) as per Department Incharge 558 Supplying Equipments for Recurring(Chemical & Glassware) as per Department Incharge 559 Supplying of Furniture Bookshelves, Study Tables and Chairs for Readers as per Department Incharge 560 Supplying of Desktop i5 Processor, 7th Generations, 500GB HDD, 4GB RAM, 23.8 inch, LED backlit Monitor Full HD IPS Panel (Brand: HP/DELL) as per Department Incharge 561 Supplying of Headphone with built in microphoneas per Department Incharge 562 Supplying of Printer with scanner (Laser,Colour/B/W)as per Department Incharge 563 Supplying of Scanner(USB,25.2D x 36.8W x 4.3H Centimeters,Slide) as per Department Incharge 564 Supplying of Xerox Machine:- (,Platen cover & Toner, Resolution (DPI):1200 X 1200dpi, Duty Cycle:1.3 Sec) as per Department Incharge 565 Supplying of Lamination Machine(Paper size-A4,A3,FS,max laminating width-500mm,Laminating speed-1200mm)as per Department Incharge 566 Supplying of CCTV Camera(Full HD Picture,AI Powered Motion Detection,Infrared Night Vision; 360° Panorama,Talk Back Feature (2-Way Audio)Material Type: Plastic; Included Components: Camera, Power Adapter, Charging Cable, Wall Mounting Kit, User Manual; Specific Uses For Product: Surveillance) as per Department Incharge 567 Supplying of 75 inch diagonal length with 3 GB RAM, 48 GB ROM 4K Display, Slim Frame, Anti-Glare Glass, 3M Anti-Glare, H7 touch surface hardness, Light weight for easy installation. Media Suits for Annotation Software. Bundle with Education Apps. Office Suits. Great Writing Experience. Object Recognition- Fist/Palm/Fine Pen, Touch Points-20 points under Android. 178 Degree viewing Angle, IR Touch. 15000:1 contrast ratio, 4MS Response Time, 50000 Hours life. Reduce cluster and bring efficiency for the faculty. Remote control, 15 watts x 2 speaker. Android 8.0 Newline Cast Display Management including wall mount and installation. as per Department Incharge 568 Supplying of RS75+ TT7519RS RS 75+ comes with 75 inch diagonal length with 3 GB RAM, 48 GB ROM 4K Display, Android Model Slim Frame, Anti-Glare Glass, 3M Anti-Glare, H7 touch surface hardness, Light weight for easy installation. Media Suits for Annotation Software. Bundle with Education Apps. Office Suits. Great Writing Experience. Object Recognition- Fist/Palm/Fine Pen, Touch Points-20 points under Android. 178 Degree viewing Angle, IR Touch. 15000:1 contrast ratio, 4MS Response Time, 50000 Hours life. Reduce cluster and bring efficiency for the faculty. Remote control, 15 watts x 2 speaker. Android 8.0 Newline Cast Display Management. as per Department Incharge 569 Supplying of Wall Mount Kit(Material: SS,Max loading capacity-60 to 100kg) as per Department Incharge 570 Supplying of Live streaming software Software Software for Live Streaming or Live telecast as per Department Incharge 571 Supplying of 75 inch diagonal length with 3 GB RAM, 48 GB ROM 4K Display, Slim Frame, Anti-Glare Glass, 3M Anti-Glare, H7 touch surface hardness, Light weight for easy installation. Media Suits for Annotation Software. Bundle with Education Apps. Office Suits. Great Writing Experience. Object Recognition- Fist/Palm/Fine Pen, Touch Points-20 points under Android. 178 Degree viewing Angle, IR Touch. 15000:1 contrast ratio, 4MS Response Time, 50000 Hours life. Reduce cluster and bring efficiency for the faculty. Remote control, 15 watts x 2 speaker. Android 8.0 Newline Cast Display Management including wall mount and installation. as per Department Incharge 572 Supplying of Frieght Transportation of 4K Display,Wall mount kit,Live Streaming software as per Department Incharge 573 Supplying of cctv solutions for Department with 20 cameras(Image Sensor Type-CMOS,Image Sensor Size-0.357 inch,Camera Image Sensing capacity (Picture Mode)-2MP,Resolution-Full HD (1920 x 1080 Pixel)-Day/Night Capable-Yes,IR illumination Range(mtr) 200 Type of Camera HousingDOME CAMERA,IP Camera Yes) as per Department Incharge 574 Supplying of installation and commisioning of CCTV and other computer equipment as per Department Incharge 575 Supplying of 55 Tv for seeing all cctv in HOD room as per Department Incharge 576 Supplying of8 PORT EPBX as per Department Incharge 577 Supplying ofTELEPHONE as per Department Incharge 578 Supplying ofWIRE as per Department Incharge 579 Supplying of CRON BOX as per Department Incharge 580 Supplying ofSWITCHES FOR PORTS as per Department Incharge 581 Supplying of Workststion Table, Chairs, Desktop, UPS as per Department Incharge 582 Supplying of LAN, Switches, Necessary Cabling, Casing Power Supply Port including Cables as per Department Incharge 583 Supplying of Refrigerator(Storage & Interior Description : | Cooling Type ; Frost Free | Display Type ; Thermostat | Shelf Material ; Toughened Glass | Compressor Type ; Reciprocatory)as per Department Incharge 584 Supplying of Microwave(Special Features: Quartz Heater - Concealed Heating. Safer Cooking, Stainless Steel Cavity - More Hygienic. More Durable, Child Lock - Ensures complete safety especially for homes with young children, Interior light)as per Department Incharge 585 Supplying of Washing Machine( Fully automatic 6 kg) as per Department Incharge 586 Supplying of Sewing Machine(Motorised)as per Department Incharge 587 Supplying of Weighting Machineas per Department Incharge 588 Supplying of Blood Pressure Monitor as per Department Incharge 589 Supplying of Oximeter as per Department Incharge 590 Supplying of Gluco Meter as per Department Incharge 591 Supplying of Test Tube & Breakers as per Department Incharge 592 Supplying of RO Water Purifier as per Department Incharge 593 Supplying of Microscope(Student) as per Department Incharge 594 Supplying of Crockery Set as per Department Incharge 595 Supplying of Cocking Utensils set as per Department Incharge 596 Supplying of Cutlery Set as per Department Incharge 597 Supplying of Sofa Set + Centre Table as per Department Incharge 598 Supplying of A.C (Split 2 Ton,3 Star,Twin invertor HD Compressor)as per Department Incharge 599 Supplying of Stabilizer(Automatic Voltage Stabilizer,37.4 x 27.1 x 19.8 Centimeters,5 kg 700 g)as per Department Incharge 600 Supplying of Inveter with battery(Capacity -100AH,Battery Type-Tubular Battery,Warranty-1 years,Protection From Short Circuit, Over Temperature, Battery Deep -Discharge,Backup Time 8 Hrs Backup- 1 FAN ,28 Light , 8 Hrs Backup - 1FAN ,1 Light Battery Condition-New) as per Department Incharge 601 Supplying of Desktop Computer with UPS and Computer Tableas per Department Incharge 602 Supplying of Original operating system software window 10 with Antivirus as per Department Incharge 603 Supplying of Printer with scanner (inkjet,Colour/B/W)as per Department Incharge 604 Supplying of Dining Table Set as per Department Incharge 605 Supplying of Camera as per Department Incharge 606 Supplying of Mixer Grinder as per Department Incharge 607 Supplying of Iron as per Department Incharge 608 Supplying of Wall Clockas per Department Incharge 609 Supplying of Whole tailoring Equipments (Local) as per Department Incharge 610 Supplying of Knitting Equipments(Local) as per Department Incharge 611 Supplying of Flower Arrangement Equipments) (local) as per Department Incharge 612 Supplying of Aluminium Set as per Department Incharge 613 Supplying of Plastic Tub as per Department Incharge 614 Supplying of Dustbin(Big) as per Department Incharge 615 Supplying of Basket &Mug as per Department Incharge 616 Supplying of White Table Cloth(Big size)as per Department Incharge 617 Supplying of Wash Basin(Local)as per Department Incharge 618 Supplying of Gas Stove +Cylinderas per Department Incharge 619 Supplying of Curtains(Local) as per Department Incharge 620 Supplying of Floor Mats (Local) as per Department Incharge 621 Supplying of Tube Lightas per Department Incharge 622 Supplying of Fan as per Department Incharge 623 Supplying of Led Projector(New Edition)as per Department Incharge 624 Supplying of Smart Board(specification:white,power consumption<150w ,usage-school,Effective touch-65x46) as per Department Incharge 625 Supplying of Decorative Items(Local) as per Department Incharge 626 Supplying of Xerox Machine (Specification-Functions:Print | Scan | Copy,Technology -Laser,Print speed-upto 60 pages/min,Paper size-A4,Connectivity-Wireless(Wi-Fi),Color output-Color | B&W, Print Volume(per month) -above 15000 ppm,Features-Two-sided printing,Weight-25kg,Dimension-451 x 460 x 360mm,Scanner type Flatbed scanner multi as per Department Incharge 627 Supplying of Ceiling Fanas per Department Incharge 628 Supplying of Exhaust Fan as per Department Incharge 629 Supplying of Pedestal Fan as per Department Incharge 630 Supplying of Inveter with battery(Capacity -200AH,Battery Type-Tubular Battery,Warranty-3 years,Protection From Short Circuit, Over Temperature, Battery Deep -Discharge,Backup Time 14 Hrs Backup- 4 FAN , 8 Light , 14 Hrs Backup - 1FAN ,1 Light Battery Condition-New) as per Department Incharge 631 Supplying of Wooden Stool(Local) as per Department Incharge 632 Supplying of Wash Basin (Local) as per Department Incharge 633 Supplying of Register (Local) as per Department Incharge 634 Supplying of Stabilizer for ACas per Department Incharge 635 Supplying of Tubelightas per Department Incharge 636 Supplying of Dustbin (Local) as per Department Incharge 637 Supplying of Curtains (Window and Door) (Local)as per Department Incharge 638 Supplying of Door Mat(Local) as per Department Incharge 639 Supplying of Broadband(Wifi)as per Department Incharge 640 Supplying of Furniture Bookshelves, Study Tables and Chairs for attendant and students (30 students at a time) as per Department Incharge 641 Supplying of Wireless mic as per Department Incharge 642 Supplying of Weight Box(100g std.) :- Containing 10 cynlinders of the same size and shape but different in weight as per Department Incharge 643 Supplying of Weight Box(50g std.) :- Containing 10 cynlinders of the same size and shape but different in weight as per Department Incharge 644 Supplying of Kymograph :-with smoked paper, smoked Drum, Time marker as per Department Incharge 645 Supplying of Memory Drum :- Electrical operated as per Department Incharge 646 Supplying of Memory Drum :- Hand operated as per Department Incharge 647 Supplying of Metronome :- Mechanical as per Department Incharge 648 Supplying of Porteuz Maze Test as per Department Incharge 649 Supplying of Techisto-scope :- Fall Drop type as per Department Incharge 650 Supplying of Techisto-scope :-Electronic as per Department Incharge 651 Supplying of Verniers chronoscope :- Pendulum Type as per Department Incharge 652 Supplying of Ergograph/Smoke drum /smoke paper varshing tray and varnish :- Hand grip model as per Department Incharge 653 Supplying of Weight 6Kg as per Department Incharge 654 Supplying of Multiplication sheets(100sheet) as per Department Incharge 655 Supplying of Screen:- Wooden as per Department Incharge 656 Supplying of Ravens Progressive Matrices as per Department Incharge 657 Supplying of Weschlers Intelligence scale (Adult) as per Department Incharge 658 Supplying of Cattles 16 PF Questionnaire as per Department Incharge 659 Supplying of Jungs Word Association Test as per Department Incharge 660 Supplying of Thematics Apperception Test as per Department Incharge 661 Supplying of Zeigarnik Effect Test as per Department Incharge 662 Supplying of The Occupational Stress Index(OSI) Scale by A.K Shrivastawa and A.P. Singh as per Department Incharge 663 Supplying of Rorschach Test as per Department Incharge 664 Supplying of Coping Strategies Test by A.K. Shrivastava as per Department Incharge 665 Supplying of Job Satisfaction scale(JSS) by Amar Singh and T.R. Sharma as per Department Incharge 666 Supplying of Job Involvement Scale by A.K. Singh and R. Kapoor as per Department Incharge. 667 Supplying ofOrganizational Climate Scale by Somnath Chatopadhya and K.G. Agarwal as per Department Incharge 668 Supplying of Managerial Aptitude Scale(MAS) by Santosh Dhar, Upinder Dhar and Priyanka Sharma as per Department Incharge 669 Supplying of Employees Motivational Scale by A.K. Shrivastava as per Department Incharge 670 Supplying of Employees Mental Health Inventory (EMHI) by Jagdish as per Department Incharge 671 Supplying of Beck Depression Inventory by Arron Beck as per Department Incharge 672 Supplying of Aggration Scale (AS) by G.P. Mathur and Rajkumar Bhatnagar as per Department Incharge 673 Supplying of Ego Strength Scale by Q. Hassan as per Department Incharge 674 Supplying of Bells Adjustment Iventory by S.M. Mohsin and Shamshad as per Department Incharge 675 Supplying of Marital Adjustment Questionnaire by P. Kumar and kanchan Rohtagi as per Department Incharge 676 Supplying of Sacks Sentence Completion Test as per Department Incharge 677 Supplying of PGI Health Questionnaire N-1 (PGIHQN) by S.K. Verma, N.N. Wig and D. Prasad as per Department Incharge 678 Supplying of Rotters Locus of Control Scal by Anand Kumar and S.N Srivastava as per Department Incharge 679 Supplying of Self Concept Inventory by O.N Srivastava as per Department Incharge 680 Supplying of PGI Social Support Scale by S.K. Verma, P. Kulhara and Ritu Nehraas per Department Incharge 681 Supplying of Emotiobnal Maturity Scale(EMS) by R.R. Trtipathi as per Department Incharge 682 Supplying of Life satisfaction Scale(LSS) by Q.G. Alam and R. Srivastava as per Department Incharge 683 Supplying of PGI Quality of Life Scale by S.K Verma and A.C. Moudgil as per Department Incharge 684 Supplying of Environmental Awareness Scale (EAS) by Haseen Taj as per Department Incharge 685 Supplying of Jatota Test of Group Mental ability as per Department Incharge 686 Supplying of Weinsteins Noise Sensitivy Scale (WNSS)(Shore Samvedi Mapak) by P. Bhatia, S. Mohar and I.S Mohar as per Department Incharge 687 Supplying of State Traight Anxiety Test (STAT) as per Department Incharge 688 Supplying of Xerox Machines (Digital)(Product Specification:Copy | Print | Scan | Fax,Number Of Trays-2,Item Color-Black,Duty Cycle-20000,Print Technology-LaserPrint Speed-25 Paper Per Minute ) as per Department Incharge 689 Supplying of Binding Machine (Product Specification:Capacity-12-15 Sheets,Binding Style-Manual ,Max Binding Thickness<20 mm Max Binding Sheet Width 200-300 mm,Automatic Grade-Semi-Automatic,Weight-5.8Kgs Approx.,Dimension-375x230x150mm Approx.Automation Grade,Hole Size-3x8mm,Paper Size-A4 /Letter /A5 etc,Packaging Weight-375 mm,Handle Type-metal,Packaging Size-375x230x150mm Approx.Adjustable Margin-2.5/4.5/6.5mm,Usage/Application-Comb Binding Method Of Operation-Manual,No Of Punch Holes-21 holes Number Of Punch Slots-21 holes,Size-A4,Number Of Punch Holes-21 holes,Machine Dimension-375x230x150mm Approx.Is It Padded)as per Department Incharge 690 Supplying of Printers(Ink End Sensor-yes,paper storage capacity-100 sheets Paper Input, 50 sheets Paper Output-printing technology ink tank,connecter type-Wi-Fi, USB,special feature-Cost per print - 9 paise (Black & White), 33 paise (Colour) as per Department Incharge 691 Supplying of Furnishing (Book shelves:Study table and chair)as per Department Incharge 692 Supplying of Book Case(for Psychological Tests) as per Department Incharge 693 Supplying of Open Racks as per Department Incharge 694 Supplying of Inveter with battery(Capacity -150AH,Battery Type-Tubular Battery,Warranty-3 years,Protection From Short Circuit, Over Temperature, Battery Deep -Discharge,Backup Time 8 Hrs Backup- 2 FAN , 2 Light , 12 Hrs Backup - 1FAN ,1 Light Battery Condition-New) as per Department Incharge 695 Supplying of Inverter with Battery(Capacity-150,Battery Type-Tubular Battery,Warranty-3 years,Protection From Short Circuit Backup Time-5hrs,Battery Condition-New)as per Department Incharge 696 Supplying of Desktop(Product Specification:Hard Drive Capacity-320GB,Operating System-Window,Screen Size-17 inch Processor-i5,Display Type LCD Processor) as per Department Incharge 697 Supplying of Tally sofware (Multi User) as per Department Incharge 698 Supplying of Barcode Machine(Product Specification:Type-Thermal Printers,Max Printing Size-10 IPS,Resolution (dpi)-203dpi Model/Type-Citizen CLS-700,Automatic Grade-Fully Automatic Print Line-1~3 Lines) as per Department Incharge 699 Supplying of Server Machines(Product Specification:Memory-1x16 GB RAM/ Open Bay- 2.5 Hot Swap SAS/ SATA,Power Supply 220 V,Networking Type-LAN,Number Of Ports/Channels-8 USB Port-Yes Processor Speed Intel Xeon Silver 4114 (Deca Core) 2.2GHz Power Consumption 750 W) as per Department Incharge 700 Supplying of LAN connection between 7 computers as per Department Incharge 701 Supplying of Xerox Machine (Specification-Functions:Print | Scan | Copy,Technology -Laser,Print speed-upto 30 pages/min,Paper size-A4,Connectivity-Wireless(Wi-Fi),Color output-Color | B&W, Print Volume(per month) -above 10000 ppm,Features-Two-sided printing,Weight-16.8kg,Dimension-451 x 460 x 360mm,Scanner type Flatbed scannercannon image Class MF641CW multi as per Department Incharge 702 Supplying of Lamination Machine(Paper size-A4,A3,FS,max laminating width-330mm,Laminating speed-600mm)as per Department Incharge 703 Supplying of Binding Machine (Punches-43 holes,Hole distance-43 holes in A 11 SHEET,Binding sizes:Max 11) as per Department Incharge 704 Supplying of Computers (Processor -AMD Ryzen 3,RAM-8GB,HDD-512 GB,screen size-19.5 inches,Operating system:Windows 11 )as per Department Incharge 705 Supplying of Office Computer (Processor:i5 10th,HDD:1 TB,RAM-4 GB,GT730 4GB Graphics) as per Department Incharge 706 Supplying oflaser printer(Product Specification:Color Output-Black & White,Function-Print | Scan | Copy,Max. Print Speed (Black)-18 ppm Max. Print Speed (Color)-17 ppm,Connectivity-Ethernet,Paper Size-A4,Print Volume-Up to 500 pages/month) as per Department Incharge 707 Supplying of Smart class Board(Power consumption:220-300V,size/Dimension-65,Input type-finger Touch) per Department Incharge 708 Supplying of Double battery(capacity-250Ah,Over current protection) Inverter(Back up time-5 hrs) as per Department Incharge 709 Supplying of Desktop Computers :- HP 23.8-inch FHD All in One Desktop with Alexa Built-in(10th Gen Intel Core i3- 1005G1/8GB/512 GB SSD/Windows 10/MS Office 2019/Natural Silver), 24-dp0816in as per Department Incharge 710 Supplying of Printer, ScannerMulti-Function Direct Wireless Network Laser Printer (Print, copy, scan, Black) as per Department Incharge 711 Supplying of Networking (LAN, leased lines, wi-fi, switches etc.) TP-Link Archer C6 Gigabit MU-MIMO Wireless Router, Dual Band 1200Mbps Wi-Fi Speed, 5 Gigabit Ports, 4 External Antennas and 1 Internal Antenna WiFi Coverage with Access as per Department Incharge 712 Supplying of Back up support(UPS, Generator, Transformer):-600VA UPS for Desktop/PC/Computers(not for Routers) with Automatic Voltage Regulation as per Department Incharge 713 Supplying of Xerox Machine:- (IR2004 With Duplex, Platen cover & Toner, Resolution (DPI):600 X 600dpi, Duty Cycle:4.3 Sec) as per Department Incharge 714 Supplying of IBM SPSS(Statistics Package Latest Version) as per Department Incharge 715 Supplying of Nvovo(Package) as per Department Incharge 716 Supplying of LCD Projector:- 1)Project movies,images or data from your devices,most effective in dark settings 2)Projector, Lens Cover/Stand, Carrying Pounch, USB Cable 3) Connect via Wi-Fi to Android smartphones and tables or connect HDMI to iPhone or iPad as per Department Incharge 717 Supplying of Projector Screen:- 1)10 Feet x 6 Feet, 133 Dia, 16:9 Format, UHD-3D-4K 2)Comes with FULL HD 1080P 3D and 4K Viewing Technology, Anti UV coating as per Department Incharge 718 Supplying of DTH connection:- 1)HD Set Top Box 2)Recording facility as per Department Incharge 719 Supplying of Television Set:- 1) Smart LED TV-42 inches 2)4K UHD (Resolution:3840x2160) 3)Connectivity-Input:3*HDMI,3*USB 4)Audio:20W output 5) 4K HDR provides exceptional clarity 6)Smartphone connectivity : Photo sharing plus, screen mirroring as per Department Incharge 720 Supplying of as per Desktop:- Intel i7, 8th Gen, 4GB N-Vidia Geforce Graphics card, 16 GB RAM, Monitor, CPU, Mouse, key board partment Incharge 721 Supplying of Multifunction Laser Printer,Scanner, and Copier :- Functionality: Print, Scan,Copy Print Technology : Monochrome Laser Connectivity: Hi-speed USB, Compatible with USB 2.0 Specifications4as per Department Incharge 722 Supplying of Speaker 7.1 surround stereo(Power -100W,Play tme-11 hours,Voice Range-9m) as per Department Incharge 723 Supplying of Digital SLR Camera: 1)EOS full HD movie mode with movie service 2)18 megapixel CMOS)APS-(sensor 3)14-bit A/D conversion 4)ISO 100-12800)EXPANDABLE TO h:25600(5)Dual Lens camera 55-250mm IS II lens 6) Camera battery charger and bag 7)Wide strap USB cable, software CD. as per Department Incharge 724 Supplying of 24.2MP DigitalSLR Camera:- 1)100% Viewfinder Coverage 2)CMOS sensor with impressive high-resolution result 3)Camera battery, charger, and bag 4)Wide strap USB cable, software CD, manual as per Department Incharge 725 Supplying of Quark express as per Department Incharge 726 Supplying of Adobe Suite(CS6 Master Collection) as per Department Incharge 727 Supplying of Cool Edit Pro as per Department Incharge 728 Supplying of Turnitin as per Department Incharge 729 Supplying of Sound Forge as per Department Incharge 730 Supplying of 18-55mm normal lens as per Department Incharge 731 Supplying of 55-250mm Zoom lens as per Department Incharge 732 Supplying of 18-135mm lens as per Department Incharge 733 Supplying of 35mm prime lens as per Department Incharge 734 Supplying of 80mm macro lensas per Department Incharge 735 Supplying of Tripods as per Department Incharge 736 Supplying of DSLR:- 1)Powered by NP-F570 InfoLithium rechargeble battery pack 2)Records to MiniDV tape stock 3)16:9 widescreen recording 4)3CCD video camera 5)12x optical zoom lens 6)Records to MiniDV tape stock as per Department Incharge 737 Supplying of:- 1)3CCD video camera 2) Crystal Engine 3)Shoulder -Type Design 3)One Touch Navigation 4)Manual Focus Ring 5) 0 lux colour light view 6)10x optical zoom 6)500x digital zoom 7)Super image stabilizer 8) DV IN/OUT Terminal 8)5-mode programme AE: sports, portrait, low light, spot light, and surf &snow 9)SP/I.P recording 10)Back light compensation 11) Cinema mode )16:9 aspect ratio( 12)Infra-red remote controller as per Department Incharge 738 Supplying of Tripods:- 1)3-way head with adjustable pan 2)Steady rubberized legs 3)Multipurpose head with quick release 4)Multipupose head for DV cameras 5)Made from High Grade Aliminium Alloy 6)Quik flip leg locks 7)Fluid pan&tilt movement 8)Quik release plate& Bubble Level as per Department Incharge 739 Supplying of i-Mac(Product Specification,Storage Capacity-256 GB Display-24 inch,Memory Size-256gb ssd,assembled Product Dimensions L X W X H,461 mm x 547 mm x 130 mm, 4.48 kg Color-Silver & Blue,Graphics-8_core GPU,Video Support And Camera 4.5K,Bluetooth-Bluetooth 5.0,Weight-4.48kg,Operating System-macOS Big Sur,Processor- M1Echip,Line Voltage-100-240V AC) for Video Editing as per Department Incharge 740 Supplying of Photographic Design Flash Bender-Small Reflector:- 1) Make a bounce flash reflector, gobo, or snoot 2)Packs flat/great for travel 3)Attaches quickly & securely 4)Adjustable to fit all popular brands of accessory flash 5)For on-camera or off-camera flash as per Department Incharge 741 Supplying of Rim Collapsible softbox Diffuser with Rim :-1)Softbox 36 inches/90 Centimeters with Grey Rim and Bowens Mount, Portable and Quick Folding Softbox Diffuser for Photography Speedlites Flash Monolight 2)for 660 LED Panel-Outer 16.3x6.5 inches,Inner 9.8x8.7 inches Collapsible Light Reflector 3)with Stap Attachment and Carrying Bag for Photo Studio Portrait Video Shooting as per Department Incharge 742 Supplying of Handheld Camera Stabilizer with Quik Release for DSLR:- 1)Light weight, handheld video image stabilization 2)FlyCam 3000 video cam stabilizer accepts camera upto 3.5kg/7.7Ibs. 3)Easy attach a small LCD monitor with Flycam 3000 cam stabilizer when needed. 4)Precision Aluminum made 5)23 tall and just 207 Ibs without counter balance disc. as per Department Incharge 743 Supplying of Green/Blue matte screen )Chroma key( :- 1)8x12 ft Blackboard, perfect for television, video production and digital photography. 2)Rod pocket on each top edge allows to be draped or hung. 3)Finishing along all edges to prevent tears. 4)Made of 100 %pure cotton, good vertical sense and durable as per Department Incharge 744 Supplying of Professional Grade Backdrop Cum Light Stand of 8 Feet Height:- 1)Photography Backdrop Stand Kit. 2)Stand of 8 Feet Height 3)8x12 ft Blackboard, perfect for television, video production and digital photography. 4) Package Contents; 1Pcs White Backdrop , 1Pcs Black Backdrop and Set of Black Backdrop stand. 5)Bag to carry as per Department Incharge 745 Supplying of Video Mixer (Four Channel Digital Video Mixer With Effects, including installation and training):- 1) four channel video mixer by incorportating HDMI inputs/outputs, USB streaming, HDCP support, built-in touch multi-viewer, and audio embedding . 2)(3Input)SD HDMI/Composite +(1Input) Up to1080p HDMI/RGB/Component/Composite. 3) PGM Output) Up to 1080p HDMI + RGB/Component +Composite +(PVW Output)PVW/Multiviewer(. 4)480p/576p Progressive internal processing 5.) Built-in multi-viewer ith touch control 6). Built-in frame synchronizers on all inputs 7). Scalers on CH 4 and Output 8). 259 Transitions 148 Effects 9). HDCP Compliant 10) Audio Embedding 11) Audio Mixer & Delay -up to 4 Fframes 12) USB Streaming Out for web-streaming 13) Video Processing:4:2:2 )Y/b/Pr(8 bits)Internal Processing :480/59.94p when set to NTSC, 576/50p when set to PAL( 14) Input Formats :HDMIVideo: INPUT 1 to3 : reqyires 720x480/59.94p )when set to NTSC( 576/50p ) When set to PAL(15) Input Formats : HDMI and Component Video : INPUT 4:480/59.94p, 720/59.94p, 1080/59.94i, 1080/59.94p )when set to NTSC (576/50i, 576/50p, 720/50p, 1080/50i, 1080/50p )when set PAL( as per Department Incharge 746 Supplying of Studio Condenser Microphone :- 1)Professional, large-diaphragm condenser microphone for unsurpassed audio quality 2) Idea as Mian and support microphone for studio and live applications. 3) Cardioid pickup pattern for outstanding sound source separation and feedback rejection 4)Pressure-gradient transducer with shock-mounted capsule. 5)Ultra-low noise, transformerless FET inputeliminates low-frequency distortion. 6) LED indicates phantom power operation. 7)Swivel stand mount and transport case included. 8)Ultra-rugged construction with metal die-cast body 8)Gold-plated 3-pin XLR output connector for highest signal integrityas per Department Incharge 747 Supplying of Digital Monitor/Speaker System(in Pair) :- 1)Two-way active monitor system for multimedia workstations and keyboard monitoring 2)High-power woofers and tweeters powered provided a linear frequency response 3)optical and coaxial inputs to directly connect digital audio sources via S/PDIF interface 4)Two stereo analogue inputs featuring 1/8 TRS and stereo RCA connectors can be used simultaneously or mixed with a digital stereo source 5)Features 1/4 TRS headphone connector with auto-mute function easily accessible from the front panel 6)2x Stereo Anaog Inputs )TRS and Stereo RCA Connectors( 7) 1/4-inch TRS headphone connector with Auto-mute Loudspeaker Function 8)1/8-inch TRS and Stereo RCA connectors as per Department Incharge 748 Supplying of Lapel Clip-on Microphone for DSLRs Camcorders Video Cameras and Iphone Smart Phone :- 1)Omni directional lavalier microphone, designed for Smartphones, DSLR, Camcorders, Audio recorders PC etc, perfect for video use. 2) With Omni pickup pattern, for full 360A coverage, 3) minimum 6-meter )20(cable with 3.5mm 4-pole gold plug for smarty phone connection as per Department Incharge 749 Supplying of Micophone Stand:- Steel stands for hand held microphones in studio with a base supporting system as per Department Incharge 750 Supplying of MP3 Digital Voice IC Recorder LCD :- 1)Digital Voice IC Recorder 2)LCD Screen 3) 23hrs life with 4GB Memory as per Department Incharge
Contract Date: Jun 17, 2026 Contract Value : 78.07 Crore
Government Departments No of Bidders 9
29.
Housing Urban and Rular Development #10156644 Price Bid
Tender For Renovation Of Temple Pond At Kovur; 1 Civil Work 2 Earth work open well excavation complying with relevant clauses of T.N.D.S.S. Well sinking and with lead upto 10 metre in Hard stiff clay, stiff black coton soil, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders and hard gravely soil -First depth of 2 metre 3 Removal of Excavated Excess Earth away from the site to 2K.M including loading and transportation charges etc, complete as per standard specification. 4 Cleaning The julifora jungle with uprooting 5 Earthwork excavation for foundation in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wetsand or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive and levelling the site etc., complete - Open Earthwork Excxavation 6 Supply and filling in foundation with Filling M-Sand in layer of 15cm thick well water rammed to consolidation including cost and conveyance of Sand to site including labour charges etc., complete as per standard specification 7 Plain cement Concrete 1:4:8 using 40mm size ISS HBG metal including cost and conveyance of all materials to site and labour charges and all incidential charges such as water providing etc., comlete as per standard specification 8 Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation - Plinth Beam 9 Up to 90cm 10 Up to 180cm 11 Column 12 Slab 13 Plain Cement Concrete 1:2:4 (one cement, two sand and four hard broken stone jelly) using 20mm size ISS HBG, including cost and conveyance of all materials to site and including for the mixing, laying and labour charges,complete as per standard specifications 14 Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - 15 Providing and laying in position Standardised Concrete Mix M-30 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 400Kg/ cum and maximum water cement ratio of 0.45 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone sand (M- Sand) but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. 16 Suppling and fabricating and placing in position MS(or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost ofsteel and binding wire also in all floors. 17 Plastering with cement mortar 1:5 (One part of Cement and Five part of Plastering Sand (P- Sand)) 12mm, thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications 18 Painting two coats for Exterior surface with approved Exterior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. 19 Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification. 20 Painting two coats with Ready Mixed Enamel Paint over the new iron works of approved quality and colour without priming coatincluding the cost all materials etc.,complete, in all floors. 21 Providing and laying, spreading and compacting graded stone aggregate to Wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant carriage to mixed material by tipper to site laying in uniform layers with paver in sub base/ base course on well prepared surface and compacting with vibratory roller to achieve the desired density complete as per clause 406 of MORTH specifications 22 Supplying and laying Rubberised interlocking Paver blockM40 grade Providing and laying of63mmthick high strength type conforming IS 15658-2006 of rubberized interlocking paver lock in size of minimum compressive strength of 40N/mm2 in uniform shape of approved make to be laid in flurring bone pattern with stone dust cushion below the uniform shap of approvednon skitting surface in the top and the rate including levelling the base preparation ofpavers as sub base, stone dust cushion 150mm thick layingout of pavement cut the pieces to fix the edge vibring the pavers,sweeping tranporting loading unloading of laying paver block as per standard specification,. 23 Supplying and fixing in position SFRC.Manhole covers of 90 X 90cm in size of best approved quality and as per standard specifications etc.,complete. 24 Rough stone Dry Packing for Aprons and revetments using rough stones and the cost shall inclusive all materials and labour charges etc complete 25 FRP DIE MAKING Project Name: PILLAR & TOP DESIGN Material: FRP 26 FRP PART Project Name: PILLAR - 24sq.ft (240cm x 23cm) Material: FRP 27 FRP PART Project Name: TOP DESIGN - 6 Sq.ft (50cm x 50cm) Material: FRP 28 Garden Bench model-kff-2001 4 feet,2 seater with enamel painted cast iron arm handle and seating and back with 9 wpc section size (75mmx20mmx1200) 29 Providing 3.5feet Penguin Fiber dustbin in various places on walking track with all necessary accessories etc., completye as directed by the departmental officers 30 Supply and Fixing of RCC pipe0.60cm dia including material nd labour charges etc., complete with standard specification. 31 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete 32 ELECTRICAL WORKS 33 Supply, Installation, Testing & Commissioning of Kesslec 40W Decorative Classic LED street lantern with a total Ht of the Pole shall be 4.0M, BIS certified withaluminairebodymadeofcastandspun aluminium,permanentlysealedopticalblock (IP66) with heat sink and polycarbonate protector (IK10) fitted with a VentPlug pressure equalisation unit, fixed onto a hinged spun aluminium frame, controlgearcompartment(IP44)accessedby loosening one screw for tool free opening and closing. Highly efficient temperature resistant lenses for asymmetric light distribution forprovidingexcellent photometrytooptimallycatertothe desired applications. Suitablefora galvanised painted oval shaped mounting bracket for Post Top version. Overallsystemefficiencyof120lm/Wat correlatedcolourtemperature(CCT)of3000K, colour rendering index (CRI) >70 and L70 rated lifetime of 50,000 hours. ElectricalClassI,ratedvoltage240Vac,Power Factor≥0.95,withBIScertifiedpotteddriver having internal surge protection of 4/4 kV and an additional surge protection device (SPD) of 10/10 kV (in both Common & Differential Modes). 34 The Decorative Column shall meet the following details: 4.0 metre height above the ground level made out of GI, tubular pole ‘T’ washed and primered. (ASTM A123, with minimum average GI coating of 65μm.), having two sections, bottom section of minimum 1000mm (L) x 140mm dia and the top section with minimum of 3000mm (L) x 76mm dia, in built junction looping box at bottom section with 32 A heavy duty 4 way connector for loop in & loop out. Design comply EN40 standard and basic wind speed 169kmph. The Embellishments are cast in iron and fitted to the column by grubs screw fitting. The embellishments shall be sealed to the column. The Pole Base plate should be with 250x250x12 mm. The column shall also be provided with flush door at the bottom with proper strengthening to the cut-out of the door opening.The Pole Shaft/pipe should be fabricated out of Steel tube of grade YST 210/240. Poles using pre galvanised tube or hot dip galvanised through double dip process is not acceptable. 35 The pole shaft and base plate shall be hot dip galvanized (7stage process) as per IS 2629 having minimum average DFT of 65 microns before the coating of epoxy primer. Complete pole & shall be treated with high quality epoxy zinc rich primer and thereafter coated with Polyurethane paint (marine grade) of minimum average DFT of 100 microns (Total pole thickness 165 micron).The pole shall have inbuilt junction box consist of connector for loop in loop out and provision for MCB. The pole shall be of composite’ construction designed to ‘wind load’ corresponding to a basic wind speed of 169kmph without any deformation or damage to the structure. CAT REF: 40WW WW LED & CHATSWORTH Pole 4.0M GI PU painted with Base Plate. 36 Supply and Laying of Cable 37 Supply and Laying of 4 x 16 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 38 Supply and Laying of 3 1/2 x 35 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 39 Brass Compression Gland 40 Supply and fixing of brass cable gland for 4x16sq.mm. PVC armoured LTUG cable with earth connection. 41 Supply and fixing of brass cable gland for 3-1/2 x 35 sq.mm. PVC armoured LTUG cable with earth connection 42 END Termination with Al Lugs 43 Supply and providing cable end termination of 3-1/2 x 25 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete. 44 Supply and providing cable end termination of 3-1/2 x 35 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 45 Fabrication, supplying, installation and commissioning of outdoor double door cubical feeder pillar of suitable size with locking arrangement in front & back with rain cap cover suitable for 3 phase, 4 wire 415 volt 50Hz dust and vermin proof made with CRCA sheet duly compartmentalized. and 4 strips 100A capacity aluminium bus bar with colour coded heat shrinkable insulation PVC sleeve with i/c providing & fixing following switch gears & accessories therein complete with connections, inter connections with suitable size of aluminium strips / bars/ copper wires i/c powder coated with grey paint after 7 tank treatment, painting, two no’s earthing studs, suitable base frame fabricated with 50mmx 50mm x 5mm angle iron grouted in cement concrete so as to keep the feeder pillar 200mm above the ground level, cable allay and detachable gland plates at bottom, rubber gasket for doors with locking arrangement etc. complete as required.a) 63 Amp, 25kA, FP MCCB with spreader links, door interlock assembly & operating handle - 1 No (Incomer) b) 16Amps, DP 10kA DIN rail mounted MCB 46 Earthing as per the ISI specification with an earth electrode of 2.10 metre Class B GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry 47 Supply and Run of 1 of No.8 SWG copper wire for earth connection 48 Supply and fixing of TNEB meter board suitable for 32A Three phase service connection with 3 numbers 32A fuse unit (500V) 32A neutral link and earth link (1 x 1/8 copper flat) on TW plank of size 600mm x 450mm x 19mm with supporting TW reepers of 1 thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit with 1 No 40 Amp 30 MA Four Pole RCD / RCCB (Higher End) with suitable necessary connection 49 CCTV CAMERA 50 Supply, Installation, Testing and commissioning of 32 channel 8 SATA NVR, with 6T Hard Disk Drive 4 nos, New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected,Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output  HDMI1 / VGA1 outputs provided  HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface for HDD connection, Support upto 10TB capacity for each HDD, Smart search for efficient playback. and smart playback to improve the playback efficiency,Supports VCA search for fire/ship/temperature/temperature difference detection triggered video files, POS information overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access  Hik-Connect for easy network management, 2 Gigabit Ethernet network interfaces. (Make : Hikvision / Dahua / Sony ) 51 Supply of 8MP, Internet Protocol fixed BULLET CAMERA with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behavior analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse. (Make: Dahua/Panasonic) 52 Supply, Installation, Testing and Commissioning of 55 smart LED TV with following specifications a) Full HD 1920 x1080 (4K monitor) b) IPS pannel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -3nos n) Built in LAN o) Magic remotep) Dimension 1242 x 724 x 55.1min(37). (Make: Sony/ LG /Samsung). 53 Supply and fixing of outdoor4X6PVC box with 102mm x 77mm x 102mm with all fixing accessories. 54 Supply and Clamping of CAT 6 armoured cable in suitable PVCPipe 1 thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem) i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal)IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-TIEEE 802.5 16 MB; ISDN; TPDDI; ATMii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant.Fire Rating: PVC : IEC 60332-1.iii. Conductor - Bare Copper Wireiv. Insulation - Polyethylenev. Twisting - 2 Cores to the pairvi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm. 55 Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point(Point to Point) Crimping, Testing and arrangement charges. 56 Supply and fixing of 24 Port 2SFP with Module, PoE Giga Range Lan Switch.• 24Ports10/100/1000 Base-TPoE+ 4 x Combo Gigabit UTP or Gigabit SFP slots• Support IEEE 802.3af (PoE) and 802.3at (PoE+) Standard• Equipped with IEEE 802.3az Energy Efficient Ethernet (EEE) Complaint• SupportIEEE 802.1Q VLAN traffic segregation• Access Control List (ACL) feature to enhances network security• Auto Surveillance VLAN for easy integration with IP-based surveillance systems• Loopback detection (LBD) and broadcast storm control to avoid network downtime• Quality of Service (QOS) and bandwidth control to ensure smooth operation• Support Web-based GUI, Smart Console , Network Assistance Utility• Cable diagnostics function to help troubleshooting wiring problem including Optical Fiber Cable connecting network accessories. (Make: DLINK, NETGEAR,TPLINK) 57 Supply and Fixing of Rack with Accessories -Higher end 4 U Rack with LNS unit and fan extra for the above rack. 58 Supply and Instalatin for 1KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2 Hours back up. 59 Supply, Erection of 6mLengthpole with base plate of size 300x300x12mm as per IS-875 with following specification. Pole Outter dia -76.10mm x 3.65mm Thick x 6 meter with foundation Charges. 60 GREENERIES 61 Supplying and Planting of ALSTONIAsapling of height 240 - 270 cm inpolythene bag of dia 30cm includingsupporting stack of 5 cm dia casurinapole of 10 feet height, including loadingand unloading charges, transportation,stacking of saplings at site, earth workexcavation of required size, planting ofsapling, refilling of excavated earth etc asdirected by the site in-charge. 62 Supplying and Planting of Pungam treesapling of height 240 - 270 cm inpolythene bag of dia 30cm includingsupporting stack of 5 cm dia casurinapole of 10 feet height, including loadingand unloading charges, transportation,stacking of saplings at site, earth workexcavation of required size, planting ofsapling, refilling of excavated earth etc asdirected by the site in-charge. 63 Planting of Hibiscus hawai foliage shrubvariety of height 30-45 cm in polythenebag of dia 20 cm including loading andunloading charges, transportation,stacking of saplings at site, earth workexcavation of required size, planting ofsapling, refilling of excavated earth etc asdirected by the site in-charge. 64 Supplying and Planting of Peltophorumtree sapling of height 240 - 270 cm inpolythene bag of dia 30cm includingsupporting stack of 5 cm dia casurina196 PD-895pole of 10 feet height, including loadingand unloading charges, transportation,stacking of saplings at site, earth workexcavation of required size, planting ofsapling, refilling of excavated earth etc asdirected by the site in-charge. 65 Supplying and Planting of Plumeria treesapling of height 240 - 270 cm inpolythene bag of dia 30cm includingsupporting stack of 5 cm dia casurinapole of 10 feet height, including loadingand unloading charges, transportation,stacking of saplings at site, earth workexcavation of required size, planting ofsapling, refilling of excavated earth etc asdirected by the site in-charge. 66 Supplying and Planting of Poovarasutree sapling of height 240 - 270 cm inpolythene bag of dia 30cm includingsupporting stack of 5 cm dia casurinapole of 10 feet height, including loadingand unloading charges, transportation,stacking of saplings at site, earth workexcavation of required size, planting ofsapling, refilling of excavated earth etc asdirected by the site in-charge. 67 Supplying and Planting of Albizia treesapling of height 240 - 270 cm inpolythene bag of dia 30cm includingsupporting stack of 5 cm dia casurinapole of 10 feet height, including loadingand unloading charges, transportation,stacking of saplings at site, earth workexcavation of required size, planting ofsapling, refilling of excavated earth etc asdirected by the site in-charge 68 Supplying and Planting of Saraca indicatree sapling of height 240 - 270 cm inpolythene bag of dia 30cm includingsupporting stack of 5 cm dia casurinapole of 10 feet height, including loadingand unloading charges, transportation,stacking of saplings at site, earth workexcavation of required size, planting ofsapling, refilling of excavated earth etc asdirected by the site in-charge. 69 Supplying and Planting of Shenbagamtree sapling of height 240 - 270 cm inpolythene bag of dia 30cm includingsupporting stack of 5 cm dia casurinapole of 10 feet height, including loadingand unloading charges, transportation,stacking of saplings at site, earth workexcavation of required size, planting ofsapling, refilling of excavated earth etc asdirected by the site in-charge. 70 Supplying and Planting of Syzygiumcumini tree sapling of height 240 - 270cm in polythene bag of dia 30cmincluding supporting stack of 5 cm diacasurina pole of 10 feet height, includingloading and unloading charges,transportation, stacking of saplings atsite, earth work excavation of requiredsize, planting of sapling, refilling ofexcavated earth etc as directed by thesite in-charge. 71 Planting of Aloe vera Herbal plantvariety of height 20-25 cm in polythenebag of dia 20 cm including loading andunloading charges, transportation,stacking of saplings at site, earth workexcavation of required size, planting ofsapling, refilling of excavated earth etc asdirected by the site in-charge. 72 STP ARRANGEMENTS 73 STP Arrangements 74 Air Injector 75 Water Fountain
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
31.
Public Administrative Department #10027101 Technical Bid
Tender for Item-Wise Rates Of Various Non-Schedule Items For Different Development Works / Renovation Of Conference Hall Of Paradeep Municipality. , Supply, Installation, Testing And Commissioning Of Electric High Speed Light Weight 50W 400 Mm Wall Fan Of White Colour Is A Space-Saving And Efficient Cooling Solution Designed For Optimal Air Circulation In Both Residential And Commercial Settings. Mounted On A Wall, These Fans Offer A Directed And Localized Breeze, Making Them Ideal For Spaces Where Floor Space Is Limited Or Where A Targeted Airflow Is Desired. Specification: Dimensions - 49.2D X 77.8W X 46.9H Centimeters, Noise Level-63 Db, Glossy Finish, Number Of Blades-01, Air Flow Capacity- 72 Cubic Meters Per Minute, Blade Length-400 Millimeters, Speed- 1.36E+3 Rpm, 230 Volts, Remote Type, Specification Met- Ce. Make- Havells/ Cg/ Bajaj , Supply, Installation, Testing And Commissioning Of Electric Single Phase Exhaust Fan 12Inch. Specification: 300Mm Exhaust Fan | Strong Air Suction, Rust Proof Body |Suitable For Bathroom, Kitchen, And Office. Product Dimensions 42D X 42W X 21.5H Cm, Special Feature Portable, Water Resistant, Waterproof. Make- Havells/ Cg/ Bajaj , Supply And Installation, Testing & Commissioning Of 5Kva (1Ph-1Ph) Online Double Conversion Ups Having 1Ph-1Ph With Inbuilt Isolation Transformer, With Ms Rack Rack , Dc Cable, Links With Two Years Warranty. With Back Up Of 60 Minutes. Make : Numeric - Legrand/ Delta/ Vertive Battery: For 60 Minutes Battery Back , Ms Rack, Linkd Dc Cable And Battery 12V/42Ah/16Nos.. Minimum Vah Reqd. 10080 Vah. Make-Exide Quanta / V-Guard/ Luminous , Water Purifier: Supply Of Ro Water Purifier 5 Stage Filtration, 50-55 Ltr/Hr. Capacity. Make- Lexpure/ Kent/ Livpure , Water Purifier:T Echnician Charges Towards Fitting, Fixing, Installation And Commissioning Of Ro Water Purifier 5 Stage Filtration, 50-55 Ltr/Hr. Capacity With Supply Of Clamp, Screw, Nut Bolt And Etc. As Per Requirement And Direction Of Engineer-In-Charge.Make- Lexpure/ Kent/ Livpure , Water Cooler : Supply Of 150 Ltr. Water Dispenser Is A Premium Product Suitable For Residential And Commercial Settings. Its Modern And Elegant Design Makes It A Versatile Addition To Any Space. Equipped With A 1/2 Bsp Thread Connection Type, This Dispenser Guarantees A Secure And Leak-Proof Installation. Boasting A Cooling Capacity Of 150 L/Hr, It Ensures A Constant Supply Of Cold Water. Crafted From High-Quality Stainless Steel, The Body Of This Dispenser Is Durable And Long-Lasting, Resistant To Corrosion, Rust, And Stains. Its Hot And Cold Modes Provide The Convenience Of Instant Access To Both Temperatures Of Water. 02 Nos.. Of Taps, 9.5 Rated Current, Stainless Steel Body. Item Depth (Mm)-589, Item Height (Mm)-1235, Item Weight (Kg)-64, Cooling Capacity (L/Hr)-150, Hot/Warm Water Dispensing Capacity-Na, Hot/Warm Water Dispensing Capacity Unit-Na, Cooling Storage Capacity (L)-150,Cooling Storage Capacity Unit-Liters, Normal Storage Capacity-Na, Normal Storage Capacity Unit-Na, Hot/Warm Water Storage Capacity-2, Hot/Warm Water Storage Capacity Unit-L, Package Width (Mm)-911, Package Depth (Mm)-690, Package Height (Mm)-1247, Package Weight (Kg)-74, Product Warranty-1 Year, Power Rating-Cooling (In Watts) 2100 @35C, Minimum Input Voltage Range 220 (Volts), Maximum Input Voltage Range-240 (Volts), Input Voltage Frequency (Hz)-50, Input Plug / Connector Type-3 Pin Plug , 16 Amp, Cord Length (Meters)-1.5, Function Cold | Warm, Refrigerant-R32, Usp Feature 1 Warm And Cold Dispensing Option, Usp Feature 2 Sturdy Compressor And Trouble Free Operation, Usp Feature 3 Eco- Friendly, Usp Feature 4 Silent Operation, Usp Feature 5 Food Grade Ss304 Tank. Make- Blue Star/ Kent/Usha , Water Cooler : Technician Charges Towards Fitting, Fixing, Installation And Commissioning Of 150 Ltr. Water Dispenser With Supply Of All Clamps , Screws, Nut Bolts And Etc. As Per Requirement And Direction Of Engineer-In-Charge. , Fire Extinguisher : Providing ,Fixing , Testing And Commissioning Of Carbon Dioxide (Co2) Type Fire Extinguisher, Isi Mark, Cap-4.5 Kg. Make - Safepro/Fire Shield , Fire Extinguisher : Providing ,Fixing , Testing And Commissioning Of Abc Type Fire Extinguisher, Isi Mark, Cap-6.0 Kg. Make - Safepro/Fire Shield , Fire Extinguisher : Providing ,Fixing , Testing And Commissioning Of Foam Type Fire Extinguisher, Isi Mark, Cap-9 Ltr. Make - Safepro/Fire Shield , Audio Visual Work : Supply Of Chairman Unit Long Unit- Digital With Chairman Button: Frequency Response:200 Hz To 12.5 Khz Headphones Load Impedance: 32 Ohms 1K Ohm Loudspeaker Nominal Output:72 Db special Length Of Microphone From Mounting Surface:480 Mm (18.9 In) Operating Temperature:0 ºc To +35 ºc Plug And Play Functionality For Ensuring Fast Installation And Reconfiguration Times Immunity To Mobile Phone Interference Functions Possible-To-Speak Indication Built-In Loudspeaker With Volume Control Headphones Socket: Built- In 3.5 Mm (0.14 In) Stereo Headphones Built-In Volume Control For Headphones Color-Coded Led Indicator Above Microphone Button For Showing The Following States: Microphone On, Request-To-Speak, And Possible-To-Speak Similar To Make Bosch Model No. Ccsd- Dl+Chairma N Button Complete. , Audio Visual Work : Supply Of Delegate Unit Long Unit- Digital Frequency Response:200 Hz To 12.5 Khz Headphones Load Impedance: 32 Ohms 1K Ohm Loudspeaker Nominal Output:72 Db special Length Of Microphone From Mounting Surface:480 Mm (18.9 In) Operating Temperature:0 ºc To +35 ºc Plug And Play Functionality For Ensuring Fast Installation And Reconfiguration Times Immunity To Mobile Phone Interference Functions: Possible-To-Speak Indication Request-To-Speak Indication Built-In Loudspeaker With Volume Control Headphones Socket: Built- In 3.5 Mm (0.14 In) Stereo Headphones Built-In Volume Control For Headphones Color-Coded Led Indicator Above Microphone Button For Showing The Following States: Microphone On, Request-To-Speak, And Possible- To-Speak Similar To Make Bosch Model No. Ccsd-Dl Complete. , Audio Visual Work : Supply Of Control Unit For The Ccs 1000 Digital Discussion:Built-In Mp3 Recorder With Internal Memory And Usb Recordingbuilt-In Digital Acoustic Feedback Suppression (Dafs) For Ensuring Superior Speech Intelligibility Plug-And-Play Functionality For Quick And Easy Connection Of Up To 80 Discussion Devices Native Support For Automatic Hd Camera Control. A Maximum Of Four Microphones Can Be Selected On The Control Unit. This Can Be Further Extended To 10 Microphones In The Web Browser Four Basic Microphonemanagement Mode Shall Be There: -(I) Open: Microphone Button Control With Request-To-Speak (Auto)(Ii) Override: Microphone Button With Override Of Activated(Iii) Voice: Voice Activated Microphones(Iv) Push-To-Talk (Push And Hold Button To Speak) Functions Plug- And-Play Functionality Web Browser Control Open Microphone Control Built-In Mp3 Recorder Discussion Controlsimilar To Make Bosch Model No. Ccsd-Curd Complete. , Audio Visual Work :Supply Of Extension Cable Assy 10M Similar To Make Bosch Model No. Lbb4116/10 Complete. , Audio Visual Work : Column Loudspeaker 30W, Metal, Sound Pressure Level At Rated Power /-1 W (1 Khz, 1 M)-105 / 92 Dbspl, Effective Frequency Range (-10 Db) 153 Hz‒ 17.7 Khz, Horizontal Opening Angle At 1 Khz / 4 Khz (-6 Db)-198°/ 130°,Vertical Opening Angle At 1 Khz / 4 Khz (-6 Db)-62°/ 18°,Rated Input Voltage 100 V, Rated Impedance, Full Power 333 Ω, Half Power 667 Ω, Quarter Power 1333 Ω. Similar To Make Bosch Model No. La2-Um30-D-In Complete. , Audio Visual Work : Booster Amplifier 240 W With Electrical Power Supply Input Voltage 230Vac ±10% At 50/60Hz Or 24Vdc Inrush Current 9A At 230 Vac, 11A At 24 Vdc Performance Rated Output (Rms) 240W Power Reduction On Backup Power -1 Db Frequency Response 60 Hz To 18 Khz (+1 / -3 Db At -10 Db Ref. Rated Output) Distortion 1% At Rated Power,1Khz S/N (Flat At Max Volume) 85 Db Power Consumption Max Power Consumption 760 Va Mains Operation Max Power 451W -3 Db 340W Pilot Tone 55W Idle 16W 24V Dc Operation Max Power 12.1A (290W) -3 Db 11.4A (274W) Pilot Tone 1.7A (41W) Idle 0.3A (7W) Line Input S 2X Connector 3-Pin Xlr, Balanced Sensitivity 1 V Impedance 20K Ohm Cmrr 25 Db (50 Hz To 20 Khz) Gain 40 Db 100 V. Similar To Make Bosch Model No. Lbd1935/00 Complete. , Audio Visual Work : 12-Channel Mixing Console: Max. 6 Mic / 12 Line Inputs (4 Mono +4 Stereo) / 2 Group Buses + 1 Stereo Bus / 2 Aux (Incl. Fx).Similar To Make Yamaha Model No. Mg12xu Complete. , Audio Visual Work : Wireless Handheld Microphone System With Frequency Response 50 To 20,000 Hz, Polar Pattern Unidirectional (Cardioid),Output Impedance @ 1 Khz, Typical-600 Ω,Audio Output Level -43.5 Dbv/Pa, Signal-To-Noise Ratio[1]@ 1 Khz-72 Db, Maximum Spl[1]-1000 Ω Load, @ 3% Thd-139.0 Db, Dynamic Range*1+@ 1 Khz, 1000 Ω Load-117.0 Db, L Equivalent Output Noise[1],Typical, A- Weighted-22 Db, Power Requirements +5V Dc (Nominal), 10 V Maximum. Similar To Make Shure Model No. Svx24/Pg28 Complete. , Audio Visual Work : Wireless Lapel Microphone With Frequency Response 50 To 20,000 Hz, Polar Pattern Unidirectional (Cardioid),Output Impedance@ 1 Khz, Typical-600 Ω, Audio Output Level -43.5 Dbv/Pa, Signal-To- Noise Ratio[1]@ 1 Khz-72 D, Up To 8 Selectable Channels, Up To 4 Compatible Systems, Antenna Switching Diversity, Adjustable Squelch Level, Mic / Line Switch. Similar To Make Shure Model No. Svx14/Cvl Complete. , Audio Visual Work : Hydraulic Pop-Up Box Having Multi-Connectors For Data And Power Connection, Hdmi. Connectors: 2X Power, 1X Rj45 Hdmi, 1X Vga, 1X 3.5Mm Audio Jack 1X Video, Hydraulic (Pneumatic) Open Close Movement , With Bottom Box. Similar To Make maintenance Complete. , Audio Visual Work : Interactive Display Panel:Screen Size-86, Panel Technology-Ips, Back Light Type- Direct, Aspect Ratio- 16:9, Native Resolution-3840X2160 (Uhd), Refresh Rate-60Hz, Brightness-440 Nits, Contrast Ratio- 1,200:1, Dynamic Cr- 5000:1, Color Gamut- Ntsc 72%, Viewing Angle(H X V)- 178 X178, Color Depth- 10Bit, 1.07Billion Colors, Response Time-8Ms (Gto G), Operation Hours (Hours/Day)- 16/7, Surface Treatment (Haze)-28%. Connectivity (Jack Interface):Input- Digital-Hdmi- Es(3), Hdcp2.2, Analog-Rgb, Vga(1), Audio- In, Rs232c In, Rj45(Lan), Usb3.0 Type A(4) , Usb2.0 Type A(1), Usb Type C (1), Audio Out, Touch Usb.Mechanical Specification:Bezel Color-Black, Bezel Width-15/15/15/44Mm, Weight(Head)- 58.6 Kg, Packed Weight- 75.9 Kg, Monitor Dimension(W X H X D)- 60 X 100Mm, Carton Dimensions(W X H X D) (Box Outer Size)- 2110 X 1283X225mm, Handle, Vesatm Standard Mount Interface-800X600. Key Feature:Hw-Wi-Fi, Build-In-Slot Type, Power Indicator, Auto Brightness Sensor, Sw- Webosver, Android- 11.0, Screen Share.Environment Conditions:Operation Temperature-0 °C To 40 °C, Operation Humidity-10% To 90%, Power Supply-Ac 100-240V~, 50/60Hz, Power Type-Built - In Power, Power Consumption- Typ.-385W, Max- 580W,Poweroff- 0.5W, Sound-Speaker-Inbuilt (15Wx2), Certification-Safety-Cb / Nrtl , Emc-Fcc Class A / Ce /Kc, Erp , Ops Type Power Built In Compatible,.Accessory:Power Cord 3 M*1, Usb Cable (Type A-Type B) 5 M*1, Hdmi Cable 3 M*1, Writing Pen*2Pcs, User Manual, Qsg, Carton Box, Remote Controller(Include Battery 2Ea), Wifi Module. Reponse Time-≤5Ms, Accuracy-±1Mm, Interface-Usb2.0, Protection Glass Thickness-3T (Anti-Glare), Operating System Support- Windows 7/8/10/Windows Xp/Linux/Mac/Android (Windowsxp/Linux/Mac Support One Point Touch), Multi Touch Point -Max 40 Points. Android System-Soc-Quad Core A55, Gpu-Mali G52mp2, Ram-4 Gb, Wifi-802.11 A/B/G/N/Ac/Ax (Wifi 6), Lan-Gigabit Lan, Bluetooth-Bluetooth 5.0.Make- Lg/ Samsung/ Panasonic , Audio Visual Work : Led Display Tv:Size-65 Inch, Resolution-3840 X 2160 (Uhd), Backlight Unit Type- Direct, Brightness-400Nit, Dynamic Contrast Ratio (Dynamic Mci (Hz))-1,000,000:1, Static (Panel) Contrast Ratio-1200:1, Refresh Rate-60Hz, Video: Hdr (10 Pro / Hlg)-Yes / Yes, Audio: Speaker (Sound Output)-10W + 10W, Broadcasting System: Digital Terrestrial, Cable, Satellite)-Dvb-T2/C, Hospitality Feature-Hotel Mode / Pdm / Installer Menu,0Ne Channel Map, Ip Channel Manager; External Speaker 0Ut (Int Variable/Fixed, 3.5Mm, Stereo, Single Dedtype (Gnd,L+,R+), 2W+2W With 80), Smart Feature- Web 0S Version (Web0s 6.0), Smart Home (Launcher Bar), Web Browser Pre-Loaded App (Youtube Only, ), Sdp Server Compatibility, Mood Display, Soft Ap, Wifi (Version) (802. 11Ac), Screen Share (Miracast), Smart Share, Bluetooth Audio Playback, Hdmi-Arc (Arc, Hdmi2), Signage Feature- Vertical Setup, Fail 0Ver, Play Via Url, Ntp Server Setting, Cisc0 Certi. Compatibility , Crestron Connected (Network Based Control), Dpm (Digital Power Management), Time Scheduler, Rtc (Real Time Clock), Ntp Sync Timer, Beac0n, Embedded Cm (Contents Manager), Embedded Gm (Group Manager), Supersign Sw C0mpability-Control / Control Plus, Cms(Premium), Simple Editor, Input Interface: Setside - Hdmi In (3 (2.0)), Headphone 0Ut (Phone Jack Type), Rs-232C(D-Sub 9Pin / Phone Jack) (Phone Jack, 4Pi), Jack Interface:Set Rear- Usb (2.0), Rf In, Digital Audio 0Ut (0Ptical), Externalspeaker 0Ut(3.5Mm Phone Jack), Rj45 (Usage Purpose) (Lan),Dimensi0n (Unit: Mm Kg): Vesa Compatible-300X300, Weightwithout Stand-21.5, Weight With Stand-21.8, Weight In Shipping-27.8, Size Without Stand-1454X838x57.7, Size With Stand- 1454 X 899 X 271, Size In Shipping- 1600X970x172, Bezel Width(L/R/U/B): 0N Bezel- 12.8/12.8/12.8/19.9, Power Supply (Voltage, Hz)-Ac 120 V-, 50 / 60 Hz, Power Consumption(Max)-198, Power Consumption(Typ)-169, Standby Power Consumption-Under 0.5W, Safety-Cb, Cu Tr, Emc-Ce, Remote Type-S-Con, Power Cable- Detached (1.5M, Straight Type), Onsite-3 Years.Make- Lg/ Samsung/ Panasonic , Audio Visual Work : Supply, Fitting, Fixing And Installation Of All In One Computer Desktop: Specification: Monitor - 24 Inches, Storage - 1 Tb Ssd, Memory - 16 Gb Ddr5, Processor - Intel Core I5, 14Th Generation, Windows Home, Wifi Inbuilt, Warranty-3Years, Make- Dell/ Hp/ Asus/Lenovo , Audio Visual Work : 4X4 4K Hdmi Matrix Switch Connects Any Of 4 Hdmi Sources To Any Of 4 Hdmi Displays, Supports 4K Resolutions Up To Uhd (3840 X 2160) And Dci (4096 X 2160) With Refresh Rates Of 30 Hz (4:4:4) And 60 Hz (4:2:0), Signaling Rates Up To 3.4 Gbits For Flawless 4K Output, Multiple Control Methods - System Management Via Front- Panel Pushbuttons, Ir Remote And Rs-232 Control. Similar To Make Aten Model No.Vm0404h Complete. , Audio Visual Work : Full Hd Ptz Ip Camera For Video Conferencing Which Supports1080p At 60Fps And Versatile 20X Optical Zoom, Delivers Hd Videooutput Via Ethernet, Hdmi, Usb And 3G-Sdi Simultaneously, Sensor, 1/2.8 2.16 Mp Cmos, Video Format-1080P : 60 / 50 / 30 / 25,720P : 60 / 50 / 30,Video Output (Hd) Interface,3G-Sdi / Hdmi / Ethernet / Usb3.0Optical Zoom,20X,Digital Zoom-12X,Horizontal Viewing Angle-57°,Vertical Viewing Angle-32.1°,Diagonal Viewing Angle-,65.4°, Aperture- F1.6~F3.8, Focal Length 5.33Mm~110Mm,Shutter Speed-1/1 ~ 1/10,000 Sec, Minimum Object Distance, Wide: 0.5M / Tele: 1.5M,Video S / N Ratio 50Db,Minimum Illumination-1.0 Lux (F1.6,50Ire, 30Fps), Focus System-Auto / Manual / Smart Af, Gain Control-Auto / Manual, White Balance-Auto / Manual, Exposure Control-Auto / Manual,Wdr,3D Nr Panning Angle+170° ~ - 170°,Panning Speed-225°/Sec, Tilting Angle+90° ~ -30°,Tilting Speed-225°/Sec. Similar To Make Lumens Model No.Vc-A53complete. , Audio Visual Work : Supply Of Usb &Hdmi Cable For Connectivity. Similar To Make Impression Complete. , Audio Visual Work : Supply Of 15U Rack For Controller & Amplifier. Similar To Make Netrack Complete. , Audio Visual Work : Supply Of 2 Core 1.5 Sq.Mm Flexible Speaker Cable As Per Site With Pvc Pipe. Similar To Make Krystal Complete. , Audio Visual Work : Installation, Testing & Commissioning With Transportation Loading Unloading Labour Charges Of The Entire System As Per Scope Of Work And Direction Of Engineer-In-Charge. , Inverter Air Conditioners Supply, Fitting, Fixing, Installation And Commissioning Of Split Ac Inverter Compressor, Condenser, Supports, With Cordless Remote Controller, Refrigerant Gas, Drain Pump, Etc As Per The Specifications Of The Following Capacities. Inverter 5 Star Rating. Make - Lloyd/ Lg/ Samsung 2.0 Tr 5 Star Inverter Model Split Ac: Specification:Compressor Type-Duo Rotary, Refrigerant-R-32, Power Supply: V-Hz-Ph-230 V~50 Hz 1 Phase, Operating Voltage Range:V-100 V - 300 V, Input Current (100%/50%):A-7.16 A / 4.13 A, Cooling Capacity (100%/50%):W-6340 W / 3170 W, Input Power (100%/50%):W-1630 W / 570 W, Iseer_5.06, Air Flow:M3/H-1270 M3/H, Air Throw Distance:M-12M, Electricity Consumption:Kwh-970.29 Kwh, Idu Noise:Db-43 Db, Odu Noise:Db-57 Db, Area Coverage: Sq. Metre-19.7 M2, Operating Range-Cools At 52 °C. 5 In 1 Convertible (40 / 60 / 80 / 100 / Auto), Smart 4-Way Swing, Turbo Cool, Rapid Cooling (18°C In 45 S), Installation Check, Low Gas Detection, Clean Filter Indication, Wifi Ready (Optional Wifi),Anti-Viral Dust Filter, Pm 2.5 Filter, Golden Fin Evaporator, Hidden Led Display, Stabilizer Free Operation, Strong Dehumidifier, Blow Function, 100% Copper, Eco Friendly Refrigerant(Ü),Idu Dimensions (Lxbxh) As Per Installed Unit:Cm-(116.1 X 24.0 X 34.0) Cm, Idu Dimensions (Lxbxh) As Per Sowm Label:Cm-(116.1 X 34.0 X 24.0) Cm, Idu Packing (Lxbxh):Cm-(127.0 X 41.5 X 33.5) Cm, Idu Net / Gross Weight:Kg-14.2 Kg / 18.0 Kg, Odu Dimensions (Lxbxh):Cm-(94.0 X 37.0 X 68.0) Cm, Odu Packing (Lxbxh):Cm-(102.0 X 45.5 X 74.0) Cm, Odu Net / Gross Weight:Kg-34.6 Kg / 40.4 Kg , Inverter Air Conditioners Supply, Fitting, Fixing, Installation And Commissioning Of Split Ac Inverter Compressor, Condenser, Supports, With Cordless Remote Controller, Refrigerant Gas, Drain Pump, Etc As Per The Specifications Of The Following Capacities. Inverter 5 Star Rating. Make - Lloyd/ Lg/ Samsung 1.0 Tr 5 Star Inverter Model Split Ac: Specification:Compressor Type-Single Rotary, Refrigerant-R-32,Power Supply: V-Hz-Ph-230 V~50 Hz 1 Phase, Operating Voltage Range:V-100 V - 300 V, Input Current (100%/50%):A-3.65 A /1.99 A, Cooling Capacity (100%/50%):W-3500 W / 1750 W, Input Power (100%/50%):W-830 W / 320 W, Iseer-5.2, Air Flow:M3/H-750 M3/H, Air Throw Distance:M-7M, Electricity Consumption:Kwh-520.93 Kwh, Idu Noise:Db-35 Db, Odu Noise:Db-50 Db, Area Coverage: Sq. Metre-11.0 M2, Operating Range-Cools At 52 °C, 5 In 1 Convertible (40 / 60 / 80 / 100 / Auto), Smart 4-Way Swing, Turbo Cool, Rapid Cooling (18°C In 45 S), Installation Check, Low Gas Detection, Clean Filter Indication, Wifi Ready (Optional Wifi),Anti-Viral Dust Filter, Pm 2.5 Filter, Golden Fin Evaporator, Hidden Led Display, Stabilizer Free Operation, Strong Dehumidifier, Blow Function, 100% Copper, Eco Friendly Refrigerant(Ü),Idu Dimensions (Lxbxh) As Per Installed Unit:Cm-(85.6 X 21.9 X 28.5) Cm, Idu Dimensions (Lxbxh) As Per Sowm Label:Cm-(85.6 X 28.5 X 21.9) Cm, Idu Packing (Lxbxh):Cm-(93.4 X 35.5 X 31.1) Cm, Idu Net / Gross Weight:Kg-9.0 Kg / 11.3 Kg, Odu Dimensions (Lxbxh):Cm-(87.0 X 36.5 X 56.0) Cm, Odu Packing (Lxbxh):Cm-(91.0 X 41.5 X 59.0) Cm, Odu Net / Gross Weight:Kg-24.9 Kg / 29.0 Kg. , Installation Of Split Unit : Installation & Commissioning Of Split Air Conditioners Including Inverter Compressor, Condenser, Supports, With Cordless Remote Controller, Etc. , Installation Of Split Unit : Supply, Installation, Commissioning Of Soft Copper Piping (1/4, 1/2 Inch) For Split Units , Clamping, Fittings, Etc. Both The Pipelines Shall Be Insulated With Nitrile Tubular Insulation. , Installation Of Split Unit : Supply, Installation, Commissioning Of 4C X 1.5 Sq. Mm Control Wiring Indoor To Outdoor Unit , Installation Of Split Unit : Supply, Installation, Commissioning Of Pvc Pipes Including All Cost Of Labour, Material, Conveyance, Etc. Complete And As Per The Directions Of Engineer-In-Charge. , Installation Of Split Unit : Supply, Installation, Commissioning Of Pvc Drain Pipes With Supports As Per Drawings And Specifications Of 25Mm Inner Dia Sizes. Including All Cost Of Labour, Material, Conveyance, Etc. Complete And As Per The Directions Of Engineer-In-Charge. , Installation Of Split Unit :Supply, Installation, Commissioning Of Insulation Drain Pipes Including All Cost Of Labour, Material, Conveyance, Etc. Complete And As Per The Directions Of Engineer-In-Charge. , Installation Of Split Unit : Supply, Installation, Commissioning Of Rapping Tape , Installation Of Split Unit : Supply, Installation, Commissioning Of Odu Bracket. , Installation Of Split Unit : Supply, Fitting, Fixing, Installation, & Commissioning Of Outdoor 30 Kva (280V-470V) Un-Balanced Load Three Phase, Air Cooled Servo. Specification: Standard-Iso 9001-2008 Standards, Type-Un-Balanced Type Three Phase Air Cooled, Rating-30 Kva, Input Voltage Range-280V - 470 V, Output Voltage Range-400 Volts±1%, Input Frequency-45-55 Hz, Response Time-10M Sec, Correction Speed-35 To 45 Volt Per Sec, Efficiency-Better Than 98%, Metering / Control-Digital Ac Voltmeter With Output Measure Switch, Ampere Meter For Three Phases, Core Used-Mitor Grade Core For Buck / Boost Transformer, Winding-Electrolytic Copper Grade ( F Class Insulated), Temp. Rise-35˚ C Deg. Cent. Above Ambient, Winding Temp.-Rise 40˚ C Deg., Application-Indoor/Outdoor Type, Transformer Oil-Is 335 Making (Power Oil), Output Accuracy-+/- 1 % From No Load To Full Load, Wave Form Distortion Virtually Nil, Losses At No Load-0.12% Of The Total Capacity, Losses At Full Load-0.7% At Full Load, Terminations-Suitable Bus Bars Will Be Provided In The Termination Box, Operating Temp-0 To 55 Degree Centigrade Along With 2 Nos.. Of Earthing Terminal At Both Side Of Unit And Fabricated Outdoor Stand. Make- Jyoti/V-Guard/Microtek , Installation Of Split Unit : Supply And Laying Of 10Sqrmm Single Core Copper Flexible Wire Along With Proper Safety And Clamping Arrangement. Make- Havells/ Polycab/ Kei , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Supply Of Premix Tea/Coffee Vending Machine: (Multi Option- 3 Nos.. Beverages):Technical Specifications:Supply, Fitting, Fixing, Installation And Commissioning Of Premix Tea/Coffee Vending Machine Of 3 Lane, Net Weight-18.2 Kg, Gross Weight-21.2 Kg, Dimensions (W X D X H)-340 X 485 X 625 Mm, Package Dimensions (W X D X H)-390 X 535 X 695 Mm, 3 Drinks, Gi Body Material, Front Door-Abs Moulded, Power Source-220/110V-1P, Power-1500 Watt., Start-Up Time- Up To 10 Minutes, Dispensing Rate- Up To 22 Cups In One Time Of 100 Ml, Premix Canister-3 Nos.., Water Input-Bubble Top/Pump (Optional), Hot Tank Material-Ss 304, Canister Capacity-1.1 Kg., Auto Flush-Available, Dedicated Hot Water-Yes, - Sensor Operating Range (Only For Touch Less Model Ne/Ap)- 25 Mm (1 Inch).Make - Nescafe/ Godrej/ Nestle , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Installation Charges Of Coffee Vending Machine As Per Direction Of Engineer-In-Charge. , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Ingredients: Bru Coffee Premix , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Ingredients: Nescafe Premix , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Premium Teabags (200S) , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Sugar Sachet (1Kg) , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Lemon Tea Premix , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Disposable Nescafe Paper Cup 110Ml(50Nos.) , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items 3 Supply, Fitting, Fixing And Installation Of Mini Fridge : Specification: 92L Fridge Single Star Energy Rating, Direct Cool Technology And Single-Door Design With A Capacity Of 92 Liters. Its Dimensions Are 45.5 Cm X 49.5 Cm X 84.5 Cm (W X D X H) With A Net Weight Of About 21 Kg, And It Uses R600a Refrigerant With A Fixed-Speed Compressor. It Features Toughened Glass Shelves And An Internal Manual Control Panel. , Chairs: Supply, Fitting, Fixing Of High Back Revolving Chair, Overall Dimension:- 720W ±10 X 720D ±10 X 1290H ±10 Mm, Seat& Back Of Chair Is Made Of 12Mm Hot Pressed Plywood And Connected With Ms Powder Coated L Patta Of Size 65X8mm, Seat & Back Cushioned With Pu Foam In D-45 Kg/M3 & Prime Quality Leatherette Upholstery , Seat Size:- Seat Size:- 540W ±10 X 520D ±10 X 60 Thick. ±5 Mm, Back Size:- 530W ±10 X 730H ±10 X 60Thick. ±5Mm,Mechanism: Torsion Bar Single Point Control, Provides Maximum Adjustability And Scope For Comfort, Seat & Back Moves In Same Direction, Single/ Upright Position Locking, Tilt Tension Knob To Loosen Or Tighten The Tension According To Users Body Weight, Gas Lift:- Lift -Used Gas Lift Of 100Mm Size Of Class-Iv Grade , Plastic Gas Lift Cover, Armrest:- Leatherette Upholstered On Foam Cushioned Armrest Fixed Pp Structure And Ss Frame, Armrest Fixed With Seat & Back Which Gives Comfort & Strength Both To The Chair, Chair Base & Wheels: Metal Chrome Plated Chair Base Frame Made Of 2.5Mm Thick, Base Front Edges Are In Nylon, Base Consists Of 5 Prongs With 650±5 Mm Pitch Circle Diameter, 60Mm Dia. Black Nylon - Twin Wheel Pin Castor. Make- Methodex/ Godrej/ Ayesha , Chairs: Supply, Fitting, Fixing Of Medium Back Revolving Chair, Overall Dimension:- 720W ±10 X 720D ±10 X 1160H ±10 Mm, Seat& Back Of Chair Is Made Of 12Mm Hot Pressed Plywood And Connected With Ms Powder Coated L Patta Of Size 65X8mm, Seat & Back Cushioned With Pu Foam In D-45 Kg/M3 & Prime Quality Leatherette Upholstery , Seat Size:- Seat Size:- 520W ±10 X 510D ±10 X 60 Thick. ±5 Mm , Back Size:- 530W ±10 X H 610 ±10 X 60Thick. ±5Mm,Mechanism: Torsion Bar Single Point Control, Provides Maximum Adjustability And Scope For Comfort, Seat & Back Moves In Same Direction, Single/ Upright Position Locking, Tilt Tension Knob To Loosen Or Tighten The Tension According To Users Body Weight, Gas Lift:- Lift -Used Gas Lift Of 100Mm Size Of Class-Iv Grade , Plastic Gas Lift Cover, Armrest:- Leatherette Upholstered On Foam Cushioned Armrest Fixed Pp Structure And Chrome Plated Frame, Armrest Fixed With Seat & Back Which Gives Comfort & Strength Both To The Chair, Chair Base & Wheels: Metal Chrome Plated Chair Base Frame Made Of 2.5Mm Thick, Base Front Edges Are In Nylon, Base Consists Of 5 Prongs With 650±5 Mm Pitch Circle Diameter, 60Mm Dia. Black Nylon - Twin Wheel Pin Castor. Make- Methodex/ Godrej/ Ayesha , Chairs: Supply Of Signature Fabric Arm Chair. Specification: High-Quality Plastic Construction For Lasting Durability. Ergonomic Design With Cushioned Seat And Backrest. The Glossy Lacquered Finish Resists Uv Rays And Rust. Soft-Feel Fabric Adds A Touch Of Comfort And Beauty. Easy To Clean And Maintain, Suitable For Indoor And Outdoor. Dimensions : Width (Cm) 56, Depth (Cm) 58, Height (Cm) 80, Weight (Kg) 5.2. Make- Nilkamal/ Supreme/ Cello , Induction Stove : Supply, Fitting, Fixing Of 2000W Induction Cooktop.Specification:Induction Cooktop, 2000W, 8 Cooking Options, Overheat Protection, Child Lock Function, Auto Pan Detection & Auto Power Off, Digital Display And Led Indication For Easy Operation, Fixed & Variable Cooking Options With 10 Power Settings (120 W To 2000 W), Dedicated + & - Options To Control Power Levels, Temperature As Well As Time. Make- Havells/ Bajaj/ Prestige , Induction Stove : Supply Of Stainless Steel Drinking Water Bottle, 1.0Ltr. Specification: Drift Stainless Steel Bottle 950 Ml, Size & Dimensions In Cms (L X W X H)-7.5 X 7.5 X 27.5, Size & Weight-950 Ml - 392 G, Cap Type - Screw Cap • With Lid - Yes , Care Instructions - Hand Wash Only, Package Contents - 3 X Drift Stainless Steel Bottle. Make-Milton/Cello/Borosil , Induction Stove : Supply Of Ceramic Snacks Plate Of Size 7 Inches/ 17.8 Cm Make-Milton/Cello/Borosil , Induction Stove : Supply Of Cup With Saucer For Tea/Coffee In Ceramic Make-Milton/Cello/Borosil , Induction Stove : Supply Of Transparent Drinking Water Glass Of 300Ml. Make-Milton/Cello/Borosil , Induction Stove : Supply Of Stainless Steel Snacks Spoon Make-Milton/Cello/Borosil , Induction Stove : Supply & Fixing Of Metal Chrome Finish Plain Pedal Stainless Steel 15L Capacity Dustbin With Lid & Pedal Of Free Size Dimension 30X20x20 Cm. , Induction Stove : Supply And Fixing Of Rectangular Shape Non Slip Foot Mat Of Size 4Ft. X 2Ft. , Induction Stove : Supply And Fixing Of Cotton Luxury Office Chair Towel. , Interior Work : Supply And Installation Of 12.5 Mm Thick Gypsum Glass Fiber Reinforced (Gfr) Pixello 8 / 18 With 8 Mm Circular Diameter & 18 Mm Pitch, Total Open Area 15%, Having Broadband Sound Absorption, With Size Of Boards 1200 X 2400 Mm, Having Density 700 Kg / M³ & Weight 9 Kg / M², With Fire Class 1 & P, Climate 0°C, Rh (50-70), Nrc Up To 0.80, To Be Fixed With Philips Head Screw To Suspended Gi Frames As Per The Specification For Fixing Concealed Grid Ceiling System. The Concealed Wall Paneling System Shall Include Gi Wall Channel (Wc 25) Having Thickness 0.45 Mm, Length 3600 Mm, Unequal Flanges Of 15 & 20 Mm And Web Of 25 Mm, Which Should Be Fixed Along The Perimeters Of The Wall With Nylon Sleeves And Suitable Fasteners At Every 300 Mm Centers. Then Fixed Main Channels (Mc 45) To Be Suspended With The Help Of Gi Channel Sa 25 From Reinforced Cement Concrete / Perling. The Mc 45 Channels Have Thickness 0.9 Mm, Length 3600 Mm, Equal Flanges Of 15 Mm And Web 45 Mm From The Side Wall & Fixed At Every 1200 Mm Centers, With Gi Ceiling Channel (Cc 25) Having Thickness 0.45 Mm, Length 3600 Mm, Knurled Web 35 Mm, Depth Of 25 Mm And Equal Flanges 9.5 Mm, Fastened To The Main Channel In The Direction Perpendicular To The Main Channel At Every 600 Mm Centers. The Framework Will Maintain 50 / 75 Mm Gap From The Walls. Now Lifting The Boards On The cement concrete 25 With The Help Of Screw To Get A Flush Finish. The Jointing & Finishing Of The Same Will Be Done By Using Jointing Compound, Paper Tape. The Synthetic Polyfiber Pf5 X 25 Wool Of 50 Kg Density & Width 600 Mm, 5000 Gsm To Be Laid On The Top Of The Framework / Boards. Make: Anutone / Uno Panel / Techtom. Test Certificate Of The Used Products Shall Be Submitted After Procurement Of Materials. , Interior Work : Supply And Fixing Of 1 Mm (10% +/-) Polymer Based Acoustic Louvers Ceiling Systems Of Pare Innovations Of Panel Sizes Of 265 Mm X 3060 Mm, Along With Option To Custom Size To A Maximum Of 12800 Mm In Length In Approved Shade, Manufactured In India, Made With High Temperature Thermal Transfer Technology, Waterproof, Fire Retardant And Antibacterial. Termite Resistant, Rustproof Material. Panels To Be Installed With Gi Sections Of Suitable Gauge & Size, Subject To Change According To Site Conditions. Panels To Be Installed Using Suitable, Same Shade J-Trim With Dimensions 39 X 20 X 3060 Mm (All In Mm) For Edge Profiles And Connector With Dimensions 76 X 20 X 3060 Mm, Using Same Shade For Connecting Panels, Using Outside Corner With Dimensions 61 X 63 X 3060 Mm, Which Can Be Used In +90 Degree Corners, And Inside Corner Having Dimensions 28 X 76 X 3060 Mm, Which Can Be Used For 90 Degree Corners. Panels Are Maintenance Free And Come With 10 Years Warranty For Colour & Finish Of The Panels, Including Trims Of Pare Innovations. All Material, Accessories, Ancillary Components As Per Recommendation Of Pare Innovations. , Interior Work : Supply And Fixing Of 1 Mm (10% +/-) Polymer Based Acoustic Louvers Wall Panelling Systems Of Pare Innovations Of Panel Sizes Of 265 Mm X 3060 Mm, Along With Option To Custom Size To A Maximum Of 12800 Mm In Length In Approved Shade, Manufactured In India, Made With High Temperature Thermal Transfer Technology, Waterproof, Fire Retardant And Antibacterial. Termite Resistant, Rustproof Material. Panels To Be Installed With Gi Sections Of Suitable Gauge & Size, Subject To Change According To Site Conditions. Panels To Be Installed Using Suitable, Same Shade J Trim With Dimensions 39 X 20 X 3060 Mm (All In Mm) For Edge Profiles And Connector With Dimensions 76 X 20 X 3060 Mm, Using Same Shade For Connecting Panels, Using Outside Corner With Dimensions 61 X 63 X 3060 Mm, Which Can Be Used In +90 Degree Corners, And Inside Corner Having Dimensions 28 X 76 X 3060 Mm, Which Can Be Used For 90 Degree Corners. Panels Are Maintenance Free And Come With 10 Years Warranty For Colour & Finish Of The Panels Including Trims Of Pare Innovations. All Material, Accessories, Ancillary Components As Per Recommendation Of Pare Innovations. , Interior Work : Providing, Fitting & Fixing Of Pre-Moulded Decorative Corner Beading Of Grc, Having Cross Sectional Dimension 112 X 80 Mm And Fixing The Same By Providing Pvc Plug, Screw, Cornice Adhesive, Fevicol Etc., Complete In All Respect As Per Direction Of Engineer-In-Charge. , Interior Work : Supply & Installation Of Wall Panelling Of Anutone Lisoslats Variosurco High Density Fiber Board, Made Out Of Pure Pine Wood Particles, Fr Grade Pure Pine Wood Particle Core With Test Bs 476 Part 5, Melamine Laminated Finish, Perforated Wooden Grooved Hdf Slats L16-2 (2 Mm Grooves @ 8 Mm Centres), Tongue & Groove Edge For A Seamless Look Of Linear Dimension Size 128 / 192 Mm X 2440 Mm X 16 Mm Thick, Having Density 700 Kg / M³, Weight 9 Kgs / M², 2 Mm Front Side Sound Absorber & 1076 Dis Tractor Hole, Non-Woven Acoustic To Be Pasted On Slats. Teak Teca / Beech Haya Surco Is To Be Installed By Using Gi Strut System. The Technical Parameters Are As Follows: Core Variants: Fiber Board Climate (Ocrh): 50-70 Light Reflectance: 75% Green (Rc%): 25 Hygiene (Voc, Clean Room): Low Class: 1 Nrc: 0.85 Strength, Load Capacity (Kg): Anti-Sag, Ball Impact The Concealed Wall Panelling System Shall Include Gi Wall Channel (Wc 25) Having Thickness 0.45 Mm, Length 3600 Mm, Unequal Flanges Of 15 & 20 Mm And Web Of 25 Mm, Which Should Be Fixed Along The Perimeters Of The Wall With Nylon Sleeves And Suitable Fasteners At Every 300 Mm Centres. Then Fixed Main Channels (Mc 45) Having Thickness 0.8 Mm, Length 3600 Mm, Equal Flanges Of 15 Mm And Web 45 Mm From The Side Wall & Fixed At Every 1200 Mm Centres, With Gi Cross Channel (Cc 25) Having Thickness 0.45 Mm, Length 3600 Mm, Knurled Web 35 Mm, Depth Of 25 Mm And Equal Flanges 9.5 Mm, Fastened To The Main Channel In The Direction Perpendicular To The Main Channel At Every 600 Mm Centres. The Framework Will Maintain 50 / 75 Mm Gap From The Walls. Now Clad The Wooden Anutone Slats Surco On The cement concrete 18 With The Help Of Centre & Edge Clips To Get Better Locking Of Slats. The Tongue & Groove Are To Be Properly Aligned To Get A Flush Look. Synth Anutone Poly Fiber Pf5 X 50 Wool Of 500 Gsm To Be Filled Between The Horizontal & Vertical Studs As Infiller With The Help Of Wire / Stick 7 Adhesive. Make: Anutone / Uno Panel / Techtom , Interior Work : Supply & Installation Of Anutone Pine Wood Wool Magnesia Bonded Soak Fabric Cord Binary / Triangle Design Of Selected Colours (Ref. Colour Chart), Kerf Edge Fabric Wrapped, Pine Wood Fibers Panels Of Size 600 X 600 / 1200 X 25 Mm, Having Density 400 Kg / M³, Weight 10 Kg / M², Installed By Using Gi Strut System. The Gi Strut Work Includes Cross Channels cement concrete 50 Having Thickness 0.45 Mm, Length 3600 Mm, Knurled Web 50 Mm, Depth 50 Mm & Base 100 Mm, Equal Flanges Of 13 Mm, Which Is Fastened To Wall Positioned Horizontally In A Regular Manner At 600 Mm Centers. Pvc Vinyl Core Uv Treated H Spline Having Thickness 2 Mm & Length 2400 Mm To Be Fixed, Using Z Bar Or H Spline On The Back Or Edge Of Panels / Tiles & Similar On The Back Of Channels Perpendicular To The Cross Channels cement concrete 50 At 600 Mm Centers. Kerfed Edge Fabric Wrapped Factory Panels Shall Then Be Inserted Into The H Spline Against The Wall To Perfect Fit. Panels Shall Be Back Lined With Acoustical Infill Of Anutone Synth Pf5 X 50 Mm Thick, Adhered To The Wall Using Stick 7 Adhesive. The Technical Parameters Are As Follows: Core Variant: Pine Wood Fibers Fire Class: 1 & P Acoustic - Nrc 20 Mm C10: 0.85 Climate: 0°C, Rh 50-90 Termite Resistance: Yes Light Reflectance: Colour Dependent Green Rc%: 10 Hygiene (Voc, Clean Room): Low Strength, Load Capacity (Kg), Ball Impact Make: Anutone / Uno Panel / Techtom. Test Certificate Of The Used Products Shall Be Submitted After Procurement Of Materials. , Interior Work : Supply And Installation Of 20 Mm Thick Pine Wood Wool Magnesia Bonded Colour Tiles / Panel Having Size 600 X 2400 / 1200 Mm, Having Density 400 Kg / M³ & Weight 8 Kg / M², With Fire Class 1 & P, Climate 0°C, Rh (50, 90), Nrc - 0.97 & Green (Voc, Rc%) Low, 10 To Be Fixed With Philips Head Screw By Using Concealed Ceiling System. The Concealed Ceiling System Shall Include Gi Wall Channel (Wc 25) Having Thickness 0.45 Mm, Length 3600 Mm, Unequal Flanges Of 15 & 20 Mm And Web Of 22 Mm, Which Should Be Fixed Along The Perimeters Of The Wall With Nylon Sleeves And Suitable Fasteners At Every 300 Mm Centers. Then Suspend Main Channels (Mc 45) Having Thickness 0.9 Mm, Length 3600 Mm, Equal Flanges Of 15 Mm And Web 45 Mm From The Soffit At Every 1200 Mm Centers With Suspender Angle (Sa 25) Having Thickness 0.45 Mm, Unequal Flanges Of 25 & 10 Mm. Gi Ceiling Channel (Cc 25) Having Thickness 0.45 Mm, Length 3600 Mm, Knurled Web 35 Mm, Depth Of 25 Mm And Equal Flanges 9.5 Mm, Is Fastened To The Main Channel In The Direction Perpendicular To The Main Channel At Every 600 Mm Centers. Now The Jointing & Finishing Of The Same Will Be Done By Using Sealant To Look Flush. Now, 20 Mm Strand Square Edge Of Size 600 X 2400 X 15 Mm Thick Shall Be Fixed. Apply Synthetic Poly Fiber Pf5 X 10 Acoustic Wool Of 50 Kg Density To Be Kept On The Top Of The Ceiling By Laying On The Framework. Make: Anutone / Uno Panel / Techtom. Test Certificate Of The Used Products Shall Be Submitted After Procurement Of Materials. , Interior Work : Supply And Installation Of Broadloom Carpet In Roll Form Of Approved Make, Shade & Pattern For Conference Hall. Carpet Shall Be Of Loop Pile, Of Size 500 Mm X 500 Mm, Having Pile Yarn Or Equivalent Material, Having Minimum Pile Height Of 2.9 Mm And Maximum Total Height Of 9 Mm With Backing Of 6 Mm Thick Open Cell Pu Foam. Carpets Shall Have Inbuilt Soil Protection, Fire Resistance And Antistatic Properties. Carpets Used Shall Also Be Certified From Leed / Griha, Certified With A Test For Indoor Hygiene Properties. , Interior Work : Supplying And Fixing Murals With Frame Of Natural Fibre/Putty Of Approved Size Including Cost Of All Materials, Labour, T&P Etc Required To Complete The Work As Per Drawing, Design And Direction Of Engineer-In-Charge. , Interior Work : Manufacture, Supply And Installation Of Noise (Stc 45) Fire Rated Acoustical Doors Of Size 1200 X 2100 Mm (Main Auditorium Doors). Framework Consists Of Wooden Sections Of Size 150 Mm X 75 Mm (Nominal Finished Frame Section Of 143 Mm X 65 Mm) With Self-Adhesive Type Perimeter Seals On The Perimeters Of The Frame And The Shutter Edges (Note: Shutter Is Double Edged). Fixing Arrangements Shall Be By Means Of 4 Nos.. Of G.I. Holdfast 225 Mm X 20 Mm X 4 Mm With Split End On Either Side Of The Wall, Including 8 Nos.. Of Stainless Steel Ball Bearing Hinges Of Ss 304 Quality Of Size 102 Mm X 102 Mm X 3 Mm Thick, Capable Of Taking Load Up To 120 Kg Of The Shutter, With Ss Pin, Lock Strike Plate, Shock Absorbers As Specified. 60 Mm Thick Double Leaf Shutter Of Appropriate Size Made Out Of Perimeter Railing Of Seasoned Red Marenti Hardwood (Moisture Content Limited To 18%) Of Size 100 Mm X 30 Mm And 2 Nos.. Of 6 Mm Thick Promina-60 Board, Lined With Sound Deadener (Sound Deadening Membrane 4 Mm Thick) Sandwiched Between 2 Boards On Each Side Of The Shutter Framework Using Suitable Fasteners And Duly Hot Pressed With 3 Mm Commercial / Marine Ply To Get The Required Surface For Laminate / Veneer / Paints. Cavity Is Filled With 96 Density X 50 Mm Thick Rock Wool. Doors Shall Be Provided With Acoustical Perimeter, Centre & Drop Down Seals. Make: Stairwell Studio, Tesco, Signum Doors. , Interior Work : Supplying, Fitting And Fixing In Position 32 Mm Thick Flush Door With Teak Wood Beading And 1 Mm Thick Sunmica To Both Sides Pasted With Adhesive, Including Fixing Of Fixtures Like Godrej Make Mortice Lock Having Model No. 9168, Godrej Make Door Closer Having Model No. 8340, 100 Mm Aluminium Hinges, Handle, Tower Bolt, Stopper, Including Cost Of All Materials, Labour, All Taxes, Transportation, Loading & Unloading Etc., Complete As Per Specification And Direction Of The Engineer-In-Charge. , Interior Work : Providing And Putting In Position Column / Wall Panelling As Per Approved Drawing, Made Out Of 12 Mm Thick Bwr Ply Over Framing With 1 Mm Thick Approved Colour Laminate, Including Cost Of All Materials, Labour, T & P Etc. Required For The Work, Complete In All Respect As Per The Direction Of The Engineer-In-Charge. , Interior Work : Providing And Fixing Wooden Venetian Blinds With Pelmet Of Vista Brand As Per The Approved Shade And Design, Along With All The Accessories Including Cost, Conveyance, Loading, Unloading, Taxes Of All Materials, Cost Of All Labour, Sundries And T & P Etc. Required For The Work, Complete As Per Specification And Direction Of The Engineer-In-Charge. , Interior Work : Supplying And Fixing Of Conference Table Of Size 40-0 X 8-0 X 2-6 (Veneer Finish), Made Out Of Calibrated Bwp Plywood With Approved Shade Of 1 Mm Thick Flitches Veneer. It Should Be Provided With Leg Structure Made Out Of 25 Mm Thick Ply & 32 Mm Ply Finished With Veneer For The Top. It Should Have Provision For Necessary Power (Pop-Up Box). All Exposed Edges Should Be Mechanically Edge Banded By Matching 1 Mm Thick Veneer Edge Banding With Hot Melt Glue (Jowat / Henkel). All Pressing Veneer Onto The Ply Has To Be Executed Mechanically By Hot Press And Polymerised D3 Adhesive (Kleiberit / Jowat / Henkel). The Non-Exposed Area Will Be Covered Up By 0.8 Mm Balancer Laminate. The Same Furniture Will Be Finished With Two Coats Of Sealer Followed By One Top Coat In Pu. The Pu Lacquer To Be From Sirca / Teknovance (Italy). It Should Have A Knock Down Arrangement Of Fitting. All Hardware Fittings Will Be Hettich / Hafele / Blum Make. Make By Vibe. , Interior Work : Supplying And Fixing Of Stage Table Of Size 12-0 X 2-0 X 2-6, Top Made Out Of 25 Mm Calibrated Bwp Plywood With Approved Shade Of 1 Mm Thick Flitches Veneer, Having Side Panel Continuing Up To The Floor Connected By A 16 Mm Modesty Panel. It Should Be Provided With Leg Structure Made Out Of 25 Mm Thick Ply & 32 Mm Ply Finished With Veneer For The Top. All Exposed Edges Should Be Mechanically Edge Banded By Matching 1 Mm Thick Veneer Edge Banding With Hot Melt Glue (Jowat / Henkel). All Pressing Veneer Onto The Ply Has To Be Executed Mechanically By Hot Press And Polymerised D3 Adhesive (Kleiberit / Jowat / Henkel). The Non-Exposed Area Will Be Covered Up By 0.8 Mm Balancer Laminate. The Same Furniture Will Be Finished With Two Coats Of Sealer Followed By One Top Coat In Pu. The Pu Lacquer To Be From Sirca / Teknovance (Italy). It Should Have A Knock Down Arrangement Of Fitting. All Hardware Fittings Will Be Hettich / Hafele / Blum. Make By Vibe By Transform Furnitures Pvt. , Interior Work : Providing And Fixing Wooden Podium Of Size 19-0X10-0X0-6Including Cost Of All Materials, Labours, T&P Etc Complete As Per Direction Of Engineer-In-Charge. , Interior Work : Supplying All Materials, Labour, T & P And Providing And Fixing In Position M.S. Panelled Door (Double). Supplying & Fixing Of Pantry Unit Made Out Of 16 Mm Calibrated Bwp Plywood With Approved Shade Of Laminate, With Exposed Side & Inside 0.8 Mm Balancer Laminate. All Laminates Have To Be Hot Pressed With D3 Glue (Jowat / Henkel / Kleiberit Glue). The Said Storage Should Have Two Side Panels & A Bottom Panel. The Top Will Be Moulded Granite Top. It Should Be Provided With A Back Panel Made Out Of 6 Mm Thickness. The Cabinet Should Be Provided With Two Openable Shutters Mounted With The Cabinet By Full Overlay Hinges. The Shutter Has To Be Laminated With 1 Mm Thick Lamination Hot Pressed Onto It. All Exposed Edges Should Be Mechanically Edge Banded With Pvc Edge Banded Tape (Rehau / Dolkan) Using Hot Melt Glue. It Should Have A Knock Down Arrangement Of Fitting. All Boring Has To Be Done On Cnc For Precision Of Fitting. The Hardware Will Be Of Hettich / Olive Make. The Carcass Will Be Provided With Suede Finished Edge Banded Shutters. All Accessories Are In Ss, Make By Vibe By Transform Furnitures Pvt. Ltd. , Interior Work : Providing And Painting Two Coats With Plastic Emulsion Paint Over A Coat Of Primer Of Approved Quality And Approved Shade In All Floors At All Height By Making The Surface To The Interior Plastered Surface Of Walls Smooth, Including Cost, Conveyance, Loading And Unloading And Taxes Of All Materials, Cost Of All Labour, Sundries, T & P, Scaffolding Etc. Required For The Work And Complete In All Respect As Directed By The Engineer In Charge. , Interior Work : Providing And Fixing Glass Reinforced Concrete (G.R.C) Screens In Approved Size, Pattern, Design, Shade And Thickness Of 50 Mm On Frame And Design Element In 30 Mm Thick, Having Weight Approximately Between 3.5-4 Kg Per Sq. Ft. The Above Weight And Thickness Is Considering Dimensions Of Screens Up To 2133 Mm In Height And 1219 Mm In Width And Having At Least 50% Void Space. The Screens Should Be Made From ‘53 Grade White Portland Cement Manufactured By ‘Jk Cement Or Equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber Manufactured By ‘N.E.G Japan Or Equivalent, Super Plasticizers Manufactured By ‘Basf Or Equivalent, Polymers Manufactured By ‘Basf Or Equivalent, And U.V Resistant Synthetic Inorganic Pigments Should Be Used For Pigmentation Manufactured By ‘Bayferrox (Germany) Or Equivalent. The Material Castings Should Take Place In Frp Molds. The Fixing Of Screens Should Be ‘Dry Fixing, I.E., To Be Done With M.S. Galvanized Clamps, Fixtures And Fasteners Of The Shutter Frame. , Interior Work : Signage With Letter Writing Of Brass Finish Of Approved Size As Per Direction Of Engineer In Charge
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
32.
Petroleum and Natural Gas #9973760 AOC
Tender For Civil Structural Architectural Works For Ambient Air Heater Package At Indianoil Petronas Private Limited; 1 Boring, providing and installation 600 mm dia bored cast-in-situ reinforced cement (Sulphate Resisting Portlandcement as per IS 12330) concrete piles of grade M-30 Concrete (350 Kg SR Cement /Cum) of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of concrete, boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap,temporary approach arrangement for making pile, mud pit, removal slush after completing the pile work etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). Note: Truck Mounted rotary/TMR/Tube well boring machine shall not be used. 2 Pile Chipping up to 1m or Hard Concrete and Finishing for Pile Cap. Rate including removal of rebris within site premises as directed by Incharge. 3 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge. Safe capacity of Pile is 100 to 125 Tonne. Initial Pile Load test (Test Load 2.5 times the Safe capacity) 4 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge. Safe capacity of Pile is 100 to 125 Tonne. Routine Pile Load test (Test Load 1.5 times the Safe capacity) 5 Lateral load testing of single pile in accordance with IS : Code of practice IS: 2911 (Part IV) for determining safe allowable lateral load on pile : Upto 7.5 tonne capacity pile 6 Demolishingany cement concrete (RCC/PCC) manually/ by mechanical means including disposal of material outside premises at an unobjectionable place as per direction of Engineer-in-charge. 7 DEMOLITION BRICKWORK Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within site premises up to 1000 metres lead as per direction of Engineer-in-charge. 8 Earth workexcavation in All kinds of soil by mechanical means (Hydraulic excavator)/ manual means over areas (any size, any depth) including getting out and disposal of excavated earth lead upto 1000 m within the site premises and for all lift, as directed by Engineer-in-charge. The rate shall also include filling back available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth, consolidating each deposited layer by ramming and watering including compacted up to 95% to its MDD carrying field density test to a certain compaction of soil complte in all respect as per scope of work, detailed construction drawing, as per technical specification as directed by the Engineer-in-charge. Excavation measurement restricted to PCC/Sand/GSB filling dimension. 9 GRANULAR SUB BASE (GSB) Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 53 mm to 0.075 mm) 10 FILLING WITH LOCAL EARTH Supply & filling of local earth (including royalty) by mechanical transport also including ramming & watering of the earth in layers not exceeding 20cm in depth at any place. Rate including compacted up to 95% to its MDD carrying field density test to a certain compaction of soil complte in all respect as per scope of work, detailed construction drawing, as per technical specification as directed by the Engineer-in-charge, for all lift. 11 PCC 1:3:6 / M-10 (1 Cement : 3 coarse sand (zone-ll) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) 12 REINFORCEMENT CEMENT CONCRETE Providing and laying in position ready mixed or site batched design mix M-30 (with minimum cement content of 350 kg /cum) cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Sulphate Resisting Portlandcement IS 12330, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads, staging,scaffolding; but excluding the cost of centering, shuttering, special finishing and reinforcement as per direction of the engineer-in-charge. Note: A minimum of 350 kg of cement per cubic meter shall be used. No additional payment will be made if more than 350 kg is used to achieve M30 grade concrete; the contractor shall bear the extra cost. All works upto plinth level (Up to Air Heating Structure Floor Slab Top). 13 REINFORCEMENT CEMENT CONCRETE Providing and laying in position ready mixed or site batched design mix M-30 (with minimum cement content of 350 kg /cum) cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Sulphate Resisting Portlandcement IS 12330, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads, staging,scaffolding; but excluding the cost of centering, shuttering, special finishing and reinforcement as per direction of the engineer-in-charge. Note: A minimum of 350 kg of cement per cubic meter shall be used. No additional payment will be made if more than 350 kg is used to achieve M30 grade concrete; the contractor shall bear the extra cost.All works above plinth level. 14 Centering and shuttering including strutting, propping etc. and removal of formwork. Rate including staging and scaffolding at any height.Foundations, footings, Pile Cap, ases of columns, etc. 15 Centering and shuttering including strutting, propping etc. and removal of formwork. Rate including staging and scaffolding at any height.Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 16 Centering and shuttering including strutting, propping etc. and removal of formwork. Rate including staging and scaffolding at any height.Suspended floors, roofs, landings, balconies and access platform. 17 Centering and shuttering including strutting, propping etc. and removal of formwork. Rate including staging and scaffolding at any height.Lintels, beams, plinth beams, girders, bressumers and cantilevers 18 Centering and shuttering including strutting, propping etc. and removal of formwork. Rate including staging and scaffolding at any height. Columns, Pillars, Piers, Abutments, Posts and Struts 19 REINFORCEMENT STEEL Thermo-Mechanically Treated bars of grade Fe-500D or more with fusion bonded epoxy coated & corrosion resistance steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all levels. Rate including staging and scaffolding. 20 PLINTH PROTECTION Making plinth protection 50 mmthick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-ill) derived from natural sources : 6 graded stone aggregate 20mm nominal size derived from natural sources) over 75 m mthick bed of dry brick ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 21 BRICKWORK AT ANY LEVEL Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in all shapes and sizes in : Cement mortar 1 :4 (1 cement : 4 coarse sand). Rate including staging and scaffolding etc., 22 PLASTERING Providing and laying cement plaster on surfaces with fine sand including curing etc.20mm Cement plaster of mix 1:4 (1 cement: 4 fine sand).Rate including staging and scaffolding etc., 23 CEMENT PUNNING Neat cement punning. 24 CHICKEN MESH Providing & fixing galvanized chicken wire net 20 Gauge, 20 mm mesh size in plastering work at the junction of RCC Columns/ Beams & brickwork as directed by the Engineer-in-Charge. 25 CEMENT CONCRETE FLOORING 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1 :2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. 26 HOT DIPPED GALVANIZED STRUCTURAL STEEL Supplying, Fabricating & Erecting at all levels in position steel structures fabricated out of hot dipped galvanized MS Girders, channels, Tees, angle, flats, plate, gratings, square hollow sections pipes etc. conforming to IS:2062 and/or from Hot finished welded type tubes/pipes conforming to IS:1161 for structural purpose for sheds, supports (Including cradle supports, pipe shoe, U Bolts, structural supports, Anchor Fasteners, Embedded Steel, Reinforcement Pad etc.) cat ladder, SS Tube supports, SS tube trench covers, Fencing Gate etc. of any size/dia for required design including cutting, welding, bolting,hoisting, fixing in position. The work is to be completed in all respect as per specification ,scope of work,detailed construction drawings and directions of the Engineer-in-charge.Rate including staging and scaffolding wherever required for erection and all other machineries, equipments etc., 27 FIRE SCREEN GI SHEET Supplying, fabricating, welding, bolting, riveting, assembling, and temporarily erecting a fire screen wall up to 6.0 meters high around the licensed area or facilities, using 1mm GI corrugated sheets with zinc coating not less than 275 gm/m², including all necessary accessories, staging, and scaffolding as per the alignment provided by the site engineer; maintaining the installation until completion of the Air Heating Project commissioning, followed by dismantling and safekeeping of GI sheets and structural members at IPPL scrap premises as directed by the engineer-in-charge. The rate includes all activities related to supply, fabrication, erection, dismantling, and safekeeping, while substructure concreting and structural superstructure erection will be paid separately 28 GALVALUME SHEETS Providing & fixing at all heights, levelsand locations colourfinish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). 0.71 mm, Aluminium Colour coated troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width 1092 mm, cover width 1000 mm. The rate shall include staging and scaffolding. 29 Providing and fixing of Pre-coated colour or mill finish Aluminium Roofing Accessories in 0.71 mm thickness, Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]. For colour, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50 mm with 3 mm thick EPDM seal and SS plain washer complete :The rate shall include staging and scaffolding.Precoated aluminium Ridges plain (500- 600mm) 30 Providing and fixing of Pre-coated colour or mill finish Aluminium Roofing Accessories in 0.71 mm thickness, Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]. For colour, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50 mm with 3 mm thick EPDM seal and SS plain washer complete :The rate shall include staging and scaffolding.Precoated aluminium Flashings/ Aprons (Upto 600mm) 31 Providing and fixing of Pre-coated colour or mill finish Aluminium Roofing Accessories in 0.71 mm thickness, Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]. For colour, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50 mm with 3 mm thick EPDM seal and SS plain washer complete :The rate shall include staging and scaffolding. Precoated aluminium Gutter (600 mm over all girth) 32 EXTERIOR PAINT Providing and applying two coats of high performance elastomeric anti carbonation water based acrylic polymer coating Dekguard E 2000 over the prepared concrete surface and primed with Dekguard WB Primer to achieve thickness of 200 microns. The surface imperfections if any shall be smoothly rendered using Renderoc FC. The coating shall have excellent barrier to carbon di oxide, chloride ions, sulphates, oxygen, water. Withstands substrate crack accommodation upto 2mm & cyclic movement up to 1mm. It shall have high UV resistance and highly durable in all climatic conditions. Percentage of water absorption, permeability & depth of carbonation shall be nil while compared against control concrete. The quoted rate shall include all material, surface preparation, tools, scaffoldings, safety equipment, labours, etc complete as per manufacturer’s specification.The rate shall include staging and scaffolding. 33 INTERIOR PAINT Wall painting with one Coat primer and Two coats of premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. The rate shall include staging and scaffolding. 34 BITUMASTIC PAINT Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade : Two or more coats on new work.The rate shall include staging and scaffolding. 35 HAND RAIL Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including hot dipping galvanizing of the steel section. G.I. Pipes. Rate including primer and Two Coats enamel painting.The rate shall include staging and scaffolding. 36 GROUTING Providing grouting in pockets/ bases etc(As per Technical specification), cost of grouting, including supply of materials shall be covered in the unit rates. Rates shall include cost of labour, supervision,deployment of tools & tackles, consumables, materials and other associated arrangements required to execute all the related activities. Grouting using Free flow non shrinkable grout material CONBEXTRAGP-2 or approved equivalent etc.The rate shall include staging and scaffolding. 37 SUBGRADE COMPACTION Preparation and consolidation of sub-grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth outside the property boundary in the un-disputed areas as directed by Engineer-In-Charge. 38 MANHOLE COVER & FRAME Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality M D - 10 Circular shape 500 mm internal diameter 39 PVC WATER STOPPER Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : Serrated with central bulb (225 mm wide, 8-11 mm thick) 40 CHEMICAL GROUTING OF REINFORCEMENT Chemical grouting of reinforcement steel of 16 mm to 20 mm dia rebar with 22 / 28 mm dia hole of 220 / 280 mm depth including making hole in concrete / masonry surface as required at site by using HILTI make driller with HY150 chemical compound for nserting the reinforcement after drilling and air jet cleaning etc complete, at any level, etc complete. Rate shall include all charges and preparation of surface, cutting of reinforcement, cleaning the surface, staging, scaffolding and working platform, application of necessary chemical as per manufactures specification with necessary tools and equipments, removal of debris from the site,all complete as directed by Engineer-in-Charge. 41 EXPANSION JOINTS Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) 42 UNPLASTICISED RIGID PVC PIPE Providing and fixing on wall face 110 mm dia Unplasticised Rigid PVC (UPVC) rainwater pipes conforming to IS:13592 Type-A, including all fittings & accessories & including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion: (i) Single socketed pipes : 43 SAND FILLING WITH LIME IN GSB Poviding and laying sand mixed with powder dry shell lime with available Calcium Oxide being not less than 50% and the amount of powder dry shell lime being 5% by volumne of the hard core layer using a water jet in order to force the sand in to the voids. 44 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 300 mm dia. R.C.C. pipe 45 Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 450 mm dia RCC pipes. 46 Providing and laying 150mic thick LDPE Polythene Sheets/Film for reinforced cement concrete. Rate including cutting and laying in panel wise. 47 Taking out existing CC interlocking paver blocks from Road, including removal of rubbish etc., disposal of unserviceable material out of site at unobjectionable place and stacking serviceable material within premises as per direction of Engineer - in-Charge 48 Laying of existing interlocking paver blocks of any design /shape laid in required line,level,curvature,colour & pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as/ direction of Engineer-in-charge.
Contract Date: Jan 06, 2026 Contract Value : 6.01 Crore
Boards / Undertakings / PSU No of Bidders 1
33.
Railways #9887960 AOC
Supply Of Supply, Installation, Testing And Commissioning Of Chiller Unit.Supply, Installation, Testing And Commissioning Of Chiller Unit.,Supply, Installation, Testing And Commissioning Of Chiller Unit For Dynamic Cooling Of Spin 12 Oil (Used For Hydrostatic Bearing) Suitable For Cylindrical Grinding Machine Of A And B Axle Machine Shop Wit H Following Specifications: (1) Voltage: 3 Phase 415V Ac, 50 Hz. (2) Cooling Capacity: Minimum 22,500 Kcal/ Hr Or 7.5 T.R. (3) Cooling Media: Spin 12 Oil. (The Viscosity Of The Oil Is 11 To 14 Cst @ 40 Degree Celsius). (4) Tank: Without Storage Tank. (5) Compressor: Reciprocating/ Scroll/Screw Type Of Make Emerson Copelan D Or Danfoss Only. The Capacity Shall Be Chosen As Per The Application. (6) Condenser: Air Cooled Condenser Of Suitable Capacity. (7) Evaporator: Compact Brazed Type Heat Exchanger Of Make Danfoss, Sanua Or S Wep Only. The Capacity/Volume Shall Be Properly Assessed As Per The Application. (8) Exhaust Fan: Roof Mo Unted Exhaust Fan Of Suitable Capacity. Reputed Make Like Hicool, Vericool Or Superflow Shall Be Used. (9) Fi Lter Drier And Other Refrigeration Accessories Shall Be Of Make Dry All, Danfoss Or Emersion Only. (10) Pump : Minimum 80 Lpm Capacity At Suitable Pressure To Pump To At Least 05 Meter Head . Pump Shall Be Of Reput Ed Make Like Grundfos. (11) Refrigerant Gas: R407c Or Equivalent With Lesser Gwp. (12) Temperature Contr Oller: Microprocessor Based And Shall Be User Friendly. (13) Ambient Temperature Range: Upto 50 Degrees. ( 14) Temperature Range Of Medium: 15 To 40 Degrees. (15) Required Temperature Set Point: 20 +/-2 Degree Celsius. (16) Control Voltage Shall Be 24V Dc. (17) Antifreeze Probe To Protect The Evaporator. (18) Pressur E Switch For High Pressure (Hp) And Low Pressure (Lp) And With Safety Interlock. (17) All Motors To Be Provid Ed With Circuit Breakers Of Suitable Rating. (18) All The Electrical Switch Gears Used For The Control Circuits Sh All Be Of Reputed Make. (19) Manufacturers
Contract Date: Mar 27, 2026 Contract Value : 6.46 Lakh
Government Departments No of Bidders 1
34.
Public Administrative Department #9864998 AOC
Proposed Auditorium Chair, Audio Video, Stage Lighting And Drapery For The Auditorium Of Sangeetsurya Keshavrao Bhosale Natyagruha , Supply,Installtion,Testing & Commissioning Of 200W Led Parcan Light With Latest Rdm Technology For User Friendly Operation With Below Specifications: • Light Source : 200W Single Cob Led Source • Power Factor : >0.95 @ 230V Ac 50Hz • Color Temperature : 3200K With Cri & Tlci Value > 90 • Minimum 3 Internal Fan Operation Mode With Fan Speed Control Option. • Power Cable: 3 Core 1 Sq. Mm. Copper Pvc Insulated • Channels: 1/2 Dmx-512 Channel Modes • Beam Angle: 9°/15°/20°/25°/30° Manually Selectable • Control Mode: Rdm, Dmx512 & Manual, Master/Slave, Auto Run • Fully Rdm Compliant In Dmx Mode For The Lighting Console Mentioned In This Project. • Lux @ 2M: > 40,000 @ 9° Beam Angle • Flickering Rate : More Than 10000 Fps • Dimming: 0 - 100% Electronic Dimming • Function: Strobe, Dimming •Housing:Spunaluminiumhousingwithblackepoxypolysterpowder Coated Finish. •Accessoryslotforgelframeandbarndoorshouldbeavailableorelse Fixture Will Be Rejected. • Power And Dmx: Loop In And Loop Out Compulsary • Dmx In & Out Through : 5 Pin Xlr Connectors • Certification: Ce / Bis , Supply,Installtion,Testing & Commissioning Of4 X 100W Led Blinder Effect Lightwithlatestrdmtechnologyforuserfriendlyoperationwithbelow Specifications: • Light Source : Quad Led Cob Source • Power Factor : >0.95 @ 230V Ac 50Hz • Color Temerature : 3200K, Cri & Tlci Value > 95 • R9 Value > 94 • Minimum 3 Internal Fan Operation Mode With Fan Speed Control Option. • Power Cable: 3 Core 1 Sq. Mm. Copper Pvc Insulated • Channels: 4/8 Dmx-512 Channel Modes • Beam Angle : 40° • Control Mode: Rdm, Dmx512 & Manual, Master/Slave, Auto Run •Accessoryslotforgelframeandbarndoorshouldbeavailableorelse Fixture Will Be Rejected. • Fully Rdm Compliant In Dmx Mode For The Lighting Console Mentioned In This Project. • Lux Output At 2 Mtr : > 10,000 Lux@ 40° • Flickering Rate : More Than 10000 Fps • Dimming: 0 - 100% Electronic Dimming • Power And Dmx: Loop In And Loop Out Compulsary • Dmx In & Out Through : 5 Pin Xlr Connectors • Certification: Ce / Bis , Supply,Installtion,Testing & Commissioning Of54 X 3W Led Par Light With Latest Rdm Technology For User Friendly Operation With Below Specifications: • Base Color Rgbw Color Mixing • Led Configuration : Multiple Nos Individual Rgbw Led Configuartion • Power Cable: 3 Core 1 Sq. Mm. Copper Pvc Insulated • Minimum 3 Internal Fan Operation Mode With Fan Speed Control Option. • Channels: 8 Dmx-512 • Beam Angle: 15° •Controlmode:Rdm, Dmx512&Manual,Master/Slave, Autorun,Sound Active • Fully Rdm Compliant In Dmx Mode For The Lighting Console Mentioned In This Project. • Lux @ 2M: >10,500 @ 15° Beam Angle • Dimming: 0 - 100% Electronic Dimming • Function: Strobe, Dimming, Sound Active And Master Slave. •Housing:Diecastedaluminiumormetalhousingwithblackepoxy Polyster Powder Coated Finish. •Accessoryslotforgelframeandbarndoorshouldbeavailableorelse Fixture Will Be Rejected. • Power And Dmx: Loop In And Loop Out Compulsary • Dmx In & Out Through : 5 Pin Xlr Connectors • Certification: Ce / Bis , Supply,Installtion,Testing & Commissioning Of300w Led Profile Spot Light With Latest Rdm Technology For User Friendly Operation With Below Specifications: • Light Source : Single Led Cob Source • Power Factor : >0.95 @ 230V Ac 50Hz • Color Temerature : 3200K, Cri & Tlci Value > 95 • R9 Value > 94 • Minimum 3 Internal Fan Operation Mode With Fan Speed Control Option. • Power Cable: 3 Core 1 Sq. Mm. Copper Pvc Insulated • Channels: 1/2/3 Dmx-512 Channel Modes • Beam Angle : 19° Or 15° • Control Mode: Rdm, Dmx512 & Manual, Master/Slave, Auto Run • Fully Rdm Compliant In Dmx Mode For The Lighting Console Mentioned In This Project. • Lux Output At 2 Mtr : > 27,500 Lux@ 19° Or 15° • Flickering Rate : More Than 10000 Fps • Dimming: 0 - 100% Electronic Dimming • 4 Beam Shaping Shutters •Accessoryslotforgoboandgoboholder,Iris &Colorframeshouldbe Available Or Else Fixture Will Be Rejected. • Housing: Metal Housing With Black Epoxy Polyster Powder Coated Finish Or Pvc Body With Matt Black Finish • Power And Dmx: Loop In And Loop Out Compulsary • Dmx In & Out Through : 5 Pin Xlr Connectors • Certification: Ce / Bis , Supply,Installtion,Testing & Commissioning Of 200W Fresnel Spot Light With Minimum Following Technical Specifications ? Light Source : Single Led Cob Source ? Color Temerature : 3200K ? Cri & Tlci : > 95 ? Beam Angle : 9° - 52° Manual Zoom ? Focusing Mechanism Of Lights Should Be Ss/Brass Lead Screw Type For Step Less Smooth Zooming. Sliding Type Focusing Mechanism Shall Not Be Acceptable. ? Fresnel Lens Dia Should Not Lesser Than 200Mm ? Zooming Function Of Fresnel Should Be Through Pole Operated Yoke (Pos). ? Lux Output At 2 Mtr : > 38,500 Lux @ 9° &> 2,100 Lux @ 52° ? Power Supply Driver : Ip65 Or Higher Grade With Pf >0.96 @ 230V ? Flickering Rate : More Than 20000 Fps ? Accessory Slot For Gel Frame And Gel Filter Frame Should Be Available Or Else Fixture Will Be Rejected. ? Control Protocol : Dmx & Manual ? Fully Rdm Compliant In Dmx Mode ?Manualcontrol Viatouch Pad.Tactile Switchformanualcontrolfixture Will Be Rejected. , Supply,Installtion,Testing & Commissioning Of 400W Fresnel Spot Light With Minimum Following Technical Specifications ? Light Source : Single Led Cob Source ? Color Temerature : 3200K ? Cri & Tlci : > 95 ? Beam Angle : 9° - 52° Manual Zoom ? Focusing Mechanism Of Lights Should Be Ss/Brass Lead Screw Type For Step Less Smooth Zooming. Sliding Type Focusing Mechanism Shall Not Be Acceptable. ? Fresnel Lens Dia Should Not Lesser Than 300Mm ? Zooming Function Of Fresnel Should Be Through Pole Operated Yoke (Pos). ? Lux Output At 2 Mtr : > 70,500 Lux @ 9° &> 4,100 Lux @ 52° ? Power Supply Driver : Ip65 Or Higher Grade With Pf >0.96 @ 230V ? Flickering Rate : More Than 20000 Fps ? Accessory Slot For Gel Frame And Gel Filter Frame Should Be Available Or Else Fixture Will Be Rejected. ? Control Protocol : Dmx & Manual ? Fully Rdm Compliant In Dmx Mode ?Manualcontrol Viatouch Pad.Tactile Switchformanualcontrolfixture Will Be Rejected. , Supply,Installtion,Testing&Commissioningof200wledpcspotlight, Color Temperature3200k With Motorised Zoomlatest Rdm Technology For User Friendly Operation With Below Specifications: • Lamp Source : 200W, 3200K Led • Power Factor : >0.95 @ 230V Ac 50Hz, • Cri & Tlci Value > 95, R9 Value > 94, • Minimum 3 Internal Fan Operation Mode With Fan Speed Control Option Or Else Fixture Will Be Rejected. • Channels: 2/3/5 Dmx-512 Channel Modes, • Beam Angle : 22° To 50° Motorised Zoom, • Control Mode: Rdm, Dmx512 & Manual • Fully Rdm Compliant In Dmx Mode For The Lighting Console Mentioned In This Project. • Lux Output At 2 Mtr : > 4,500 Lux@ 22° And > 1,000 Lux@ 50° • Flickering Rate : More Than 10000 Fps, • Dimming: 0 - 100% Electronic Dimming, •Dualaccessoryslotforinsertingaccessories Shouldbe Availableorelse Fixture Will Be Rejected. • Housing:Engineered Pastic Housing With Matt Black Finish, • Power And Dmx: Loop In And Loop Out Compulsary, • Dmx In & Out Through : 5 Pin Xlr Connectors, • Certification: Bis , Supply,Installtion,Testing & Commissioning Of Cecertified Led Rgbw Cycloramawashlightwithrdmprotocolandlasercutaluminiumbody Dulyepoxypolyesterpowdercoatedinblackmatttexturefinishwith Following Specifications - •Led:480X0.5Wrgbwled(120R+120G+120B+120W)Nichiaor Lumiled Make Led • Beam Angle : 96° • Detachable Assymmetric Reflector With 64°, 62° For Uniform Wash. • Light Out Put : 3000 Lux At 1 Mtrs Without Assymmetric Reflector. •Userinterface:4Noshighprecisiontactiletypeselectorswitchwith Seven Segment Display • Fully Rdm Compliant When In Dmx Mode • Dimming : 0 To 100% 8 Bit Linear Dimming • Dmx Data In / Out: 5 Pin Locking Xlr • Natural Cooling System. No Fan, No Noise. • 2.5 M Power In + 0.5 M Power Out Or 3 Mtr 3Core 1Mm² Frls & Isi Mark Cable With 3Pin Iec Male Plug • 3 Mtr Dmx Loop Cable With Cable Mount 5 Pin Locking Xlr • Lm 79 & Lm 80 Certificates Should Be Provided • Ce Certificate Should Be Enclosed To Ensure The Required Quality And Safety Of The Products. , Supply,Installtion,Testing & Commissioning Of 300W Led Beam, Spot, Wash Moving Light, Cmy + Cto Color Wheel To Achieve Desired Color With Rdm Protocol And Hi Grade Plastic Body Black Color With Following Specifications - • Zoom Angle : 7°~31° Motorised Zoom • Pan Angle 540° & Tilt Angle 270° • Light Out Put : >30,000 Lux At 2 Mtrs, • Color Wheel : 3 Cmy + 1 Cto Color Wheel + Minimum 7 Colors And Open Or More, • Fixed Gobo Wheel : Minimum 10 Fixed Gobos Or More • Rotating Gobo Wheel : Minimum 6 Rotating Gobos Or More • User Interface : 4 Nos High Precision Membrane Type Selector Switch With Lcd Display, • Fully Rdm Compliant When In Dmx Mode, • Dmx Data In / Out: 5 Pin Locking Xlr, • 3 Mtr Dmx Loop Cable With Cable Mount 5 Pin Locking Xlr, • Certification: Bis , Supply,Installtion,Testing & Commissioning Of 1500W Haze Machine, Warm Uptime30seconds,Wire,Remote,Smokeoutput20000cuft/Minat5mtr, 3.5L Tank Capacity. Output : 20000Cu.Ft/Min. , Supply,Installtion,Testing & Commissioning Of Die Cast Aluminium C - Clamp With Safety Chain Duly Epoxy Polyester Powder Coated In Black Matt Texture Finish And Safe Working Load Of 100Kg With Below Specifications. • Lock - Ms Threaded Galvanized Lock Key, • Plastic Glass Filled Nylon Moulded M6 Key. • Receptacle - 28Mm Standard Tv Spigot. • Safety - Ms Galvanized Chain With Pin. • Finish - Pretreated And Black Epoxy Polyester Powder Coated. • Self-Weight - 0.54Kg , Supply,Installtion,Testing & Commissioning Of Safety Bond With Lock Clip 1.5 Mtr Long Made With Twisted Pair Of Gi Wire Rope, 2Mm Or 3Mm Thickness With Sleeve To Be Fixed Around The Grid To Avoid Fall Of The Material In Case If The C Clamp Is Not Locked Properly. Swl 150Kgs. , Supply,Installtion,Testing&Commissioningof79mmroundidentification Name Plate Duly Epoxy Polyester Powder Coated In Matt Texture Finish. , Supply,Installtion,Testing&Commissioningofmsctrackofsize50x40 Mm Size With 3Mm Thickness Or Higher Size, Self-Weight 3.3Kg Per Mtr. All The Materials Under Gone Through 7 Tank Process With Various Chemical Treatmenttokeepthemrustfreewithanddulyepoxypolyesterpowder Coated In Black Matt Texture Finish. , Supply,Installtion,Testing & Commissioning Of Customized Ms Suspenders Made Up Of • Ms Fish Plate 150 X 150 X 6 Mm With Hardware’S If Required As Per Site Condition • Ms Angle 40 X 40 X 5 Mm Or Higher Size Required Length As Per Site Condition To Hold The C Track Rigidly Held With Swl Of 200Kg. (As Per Site Requirement). • Height Adjustable M12 Stud Of Suitable Length As Per Site Requirement Along With Suitable Hardware’S With Pipe Coupler Clamp. (As Per Site Requirement). • All The Materials Under Gone Through 7 Tank Process With Various Chemical Treatment To Keep Them Rust Free With And Duly Epoxy Polyester Powder Coated In Black Matt Texture Finish. , Supply,Installtion,Testing & Commissioning Of Ce Certified Motorised Stage Lightbarsuitablelength12mtrsaspersiterequiremnents,Suitable Capacity3phaseacmotorwithdcbrake&Gearboxwithblackepoxy Polyester Powder Coated With Following Specifications - • 40Nb, 48Mm Od Dual Barrel Dual Construction Arrangement With 75X6mm Ms Flat In Every 2 M And With 40X75 Cable Trunking With Lid. • Frill Bar Attachement. •Msfabricatedcableretractormadeupofcrcamssheet20swg 1300Mm Each Length With Hinge Rod • Specially Designed Compact 80:1 Worm Reduction Gear Box, B5 Flange. • Double Cam Type Upper And Lower Limit Controller 5Mm, 6X19 Gi Wire Rope Preformed For Lifting The Light Bar • Pile Winding Type Winch With Ms Circular Plates For Rope Winding • Safe Working Load 180 Kg , Supply,Installtion,Testing&Commissioningoffrontofhouselightbar, Length 13 Mtrs Made Using Ms 40Nbpipe Dual Barrel Construction Arrangement Undergone Through Various Chemical Treatment To Keep Them Rustfreeanddulyepoxypolyesterpowdercoatedinblackmatttexture Finish With Below Specifications: • Dual Barrel Light Bar Equipped With 40X75x40 Cable Trenching Arrangement With Lid For Better Aesthetic Look And Cable Safety. • Dual Barrel Pipe Construction Welded With Ms Flat In Every 1 Mtr For Better Strength • With Suitable Suspenders To Fix The Light Bar With Every 2Mtr Pitch. , Supply,Installtion,Testing & Commissioning Of Ce Certified Motorised Stage Utility / Props Barsuitablelength 12Mtrs, Suitablecapacity 3Phase Ac Motor With Dc Brake. & Gear Box With Black Epoxy Polyester Powder Coated With Following Specifications - • 40Nb, 48Mm Od Dual Barrel Dual Construction Arrangement With 75X6mm Ms Flat In Every 2 M. • Specially Designed Compact 80:1 Worm Reduction Gear Box, B5 Flange. • Double Cam Type Upper And Lower Limit Controller 5Mm, 6X19 Gi Wire Rope Preformed For Lifting The Light Bar • Pile Winding Type Winch With Ms Circular Plates For Rope Winding • Safe Working Load 180 Kg , Supply,Installtion,Testing & Commissioning Of Ce Certified Motorised Stage Frill Bar Suitable Length 12 Mtrs, Suitable Capacity 3 Phase Ac Motor With Dcbrake.&Gearboxwithblackepoxypolyesterpowdercoatedwith Following Specifications - • 40Nb, 48Mm Od Dual Barrel Dual Construction Arrangement With 75X6mm Ms Flat In Every 2 M. • Specially Designed Compact 80:1 Worm Reduction Gear Box, B5 Flange. • Double Cam Type Upper And Lower Limit Controller 5Mm, 6X19 Gi Wire Rope Preformed For Lifting The Light Bar • Pile Winding Type Winch With Ms Circular Plates For Rope Winding • Safe Working Load 180 Kg , Supply,Installtion,Testing&Commissioningofmssidelightingladderof Suitable Length And Width (Min 2400 Mm Height & 600 Mm Width) • Made Using 40Nb, 48Mm Od, 2Mm Thickness Ms Pipe • Suitable Suspender And Clamps Made With Ms Angle Of Size 40X40x5 Mm Thick Or Higher Size • Inverted 4-Wheeler Trolley With Flexi Adaptor Clamp, • Heavy Duty Ladder Track To Be Laid Throughout The Depth Of The Stage. • 360° Rotatable And Can Move In Unidirectional • All The Materials Under Gone Through 7 Tank Process With Various Chemical Treatmenttokeepthemrustfreewithanddulyepoxypolyesterpowder Coated In Black Matt Texture Finish. , Supply,Installtion,Testing&Commissioningof3/4Th Ms Fohside Lighting Ladder / Gallery Lighting Ladder Of Suitable Length And Width (Min 1500 Mm Height&600Mmwidth)Allthematerialsundergonethrough7tank Processwithvariouschemicaltreatmenttokeepthemrustfreewith And Duly Epoxy Polyester Powder Coated In Black Matt Texture Finish. , Supply,Installtion,Testing&Commissioningofmsfabricated4way10a, 250Va.C,Iec,Lightingjunctionboxmadeupof22swgcrcaforled Lighting Fixtures With Pipe Clamp Arrangement For Fixing On Pipe Grid Or Raul Plugarrangementforwall/Floorfixing,Dulyblackepoxypolyesterpowder Coated Texture Finish. , Supply,Installtion,Testing&Commissioningofmsfabricated2way10a, 250V A.C, Iec,Junction Box Made Up Of 22Swg Crca With Rocker Switch To Power Up Splitter And Console With Pipe Clamp On Pipe Grid Arrangement For Fixingorraulplugarrangementforwall/Floorfixing,Dulyblackepoxy Polyester Powder Coated Texture Finish. , Supply,Installtion,Testing&Commissioningofmsfabricated5pindmx Signalinjunctionboxfittedwith5pindmxmalesocket,Junctionbox Madeupof22swgcrca,Withpipeclamponpipegridarrangementfor Fixing Or Raul Plug Arrangement For Wall/Floor Fixing, Black Epoxy Polyester Powder Coated, Duly Black Epoxy Polyester Powder Coated Texture Finish. , Supply,Installtion,Testing&Commissioningofmsfabricated5pindmx Signal Out Junction Box Fitted With 5 Pin Dmx Female Socket, Junction Box Madeupof22swgcrca,Withpipeclamponpipegridarrangementfor Fixing Or Raul Plug Arrangement For Wall/Floor Fixing, Black Epoxy Polyester Powder Coated, Duly Black Epoxy Polyester Powder Coated Texture Finish. , Supply,Installtion,Testing & Commissioning Of Fabricated 5 Pin Dmx Signal Loop Junction Box Fitted With 5 Pin Dmx Male & Female Socket With 0.3 Mtr Dmx Loop Cable Fitted With 5 Pin Dmx Cable Mount Plug, Junction Boxmade Up Of 22Swg Crca, With Pipe Clamp On Pipe Grid Arrangement For Fixing Or Raulplugarrangement Forwall/Floorfixing,Black Epoxypolyesterpowder Coated, Duly Black Epoxy Polyester Powder Coated Texture Finish. , Supply,Installtion,Testing & Commissioning Of Well Designed And Engineered Rack Mount Chocolate Brown Epoxy Polyester Coated Type Power Distribution Centrepanelwithnecessarymeteringlikevoltmeterammeter,Selector Switch,Indicators,Outgoingfeedersandmainincomer100amccband Emergencytriparrangementwithshuntreleaseand42waymcbpanel Rackmount, Internallywiredtocontrolindividualdirectlightpointswith Suitablemcbswithproperearthingandsuitablebrassglandsforouting Power Cables With Rack. , Supply,Installtion,Testing & Commissioning Of Auxiliary Marshalling Box For Power And Signal Cable Termination In Grid Level And In Motorised Light Bar • Ce Marked Fc/Pg Cable Entry Gland Required Nos As Per Cable Entry. •Mschannelarrangingtofixterminalconnector,Requirednoswith Separation Plate And Each End Is Completed With Adding End Plate With End Cap. • Grey Terminal Connector With Each Line Having P, N, E Indication For Each Line Incoming And Out Going Cable Connectors. • Box Door Must Be Made With Hingeable Door With Screw Lock. • Made Up Of 20Swg Crca Sheet Undergone Through 7 Tank Process With Variouschemicaltreatmenttokeepthemrustfree,Dulyepoxypolyester Powder Coated With Matt Black Texture Finish. , Supply,Installtion,Testing&Commissioningofpowermarshallingboxfor Power Cable Termination In Grid Level. • Ce Marked Fc/Pg Cable Entry Gland Required Nos As Per Cable Entry. •Mschannelarrangingtofixterminalconnector,Requirednoswith Separation Plate And Each End Is Completed With Adding End Plate With End Cap. • Grey Terminal Connector With Each Line Having P, N, E Indication For Each Line Incoming And Out Going Cable Connectors. • Box Door Must Be Made With Hingeable Door With Screw Lock. • Made Up Of 20Swg Crca Sheet Undergone Through 7 Tank Process With Variouschemicaltreatmenttokeepthemrustfree,Dulyepoxypolyester Powder Coated With Matt Black Texture Finish. , Supply,Installtion,Testing & Commissioning Of Motor Cable Termination Box For Power Cable Termination At Grid Level. • Ce Certified Fc/Pg 11 & 13.5 Cable Entry Gland Required Nos As Per Cable Entry. •Mschannelarrangingtofixgreyterminalconnector,Requirednoswith Separation Plate And Each End Is Completed With Adding End Plate With End Cap. •Greyterminalconnectorwitheachlinehavingl1,L2,L3,E,6,2,4 Indication For Each Line Incoming And Outgoing Cable Connectors (L1, L2, L3, E For Power Supply & 6 , 2 , 4 For Limit Switch Connection) • Box Door Must Be Made With Hingeable Door With Screw Lock. •Gridmountfixingarrangementforfixingongridoranchorfastenerfor Wall/Floor Fixing •Msboxemadeupof20swgcrcasheetundergonethrough7tank Process With Various Chemical Treatment To Keep Them Rust Free, Duly Epoxy Polyester Powder Coated With Matt Black Texture Finish. , Supply,Installtion,Testing&Commissioningofmsfabricatedcombined6 Way Motor Control Center Panel Cum Remote Controlpanel For Light Bar, Frillbarandutilitybarsystemmadeupof14swg/16Swg/18Swg Crcasheetundergonethrough7tankprocesswithvariouschemical Treatment To Keep Them Rust Free, Duly Epoxy Polyester Powder Coated With Matt Seaman’S Grey Texture Finish With Following Specifications. • 16A Tp Or Tpn Incomer. • Main Contactor Of 9A 240V 4 Pole Contactor With 04 -06A Over Load Relay For Safety • 24V 4 Pole Low Voltage Contactors • 240V / 24 V Step-Down Transformer For Low Voltage Contactors • All The Frls Pvc Isi Marking Cables Inside The Panel Routed Through Pvc Gray Color Cable Trough. • Red Color Mushroom Head Push Button For Emergency Stop • Yellow Color Reset Push Button • Master Sector Actuator Switch With 3 Position Up, Down & Off • Spring Return Selector Switchfor Each Hoist With Up & Down Indication. • All The Cables Inside The Panel Routed Through Pvc Gray Color Cable Trough. • Panel Including Wiring With Proper Earthing. , Supply,Installtion,Testing & Commissioning Of Rdm Compatible Dmx Splitter Unit With Minimum Following Specifications. ? 1 Nos 5 Pin Dmx In Socket And 8 Nos 5 Pin Dmx Out Socket ? In And Out Signal Optically Isolated ? Led Indicator For Check The Signal Flow In Output. ?Suitable For Standard 19” Cabinet ? Duly Black Epoxy Polyester Powder Coated Texture Finish. , Supply,Installtion,Testing&Commissioningof2048channel4universe Lighting Controller With ? Builtin Artnet & Wifi, ? 40 Multifunction Fixture Faders ? 10 Playback Faders With 9.7 Touch Screen, ? Fixture Library & Fx Generator, ? 10 Cue-Stacks & 10 Chases, ? Offline Software And App Control , Supply,Installtion,Testing&Commissioningof5pinxlrmale/Female Connectorsofmadeupofextrahightemperatureresistantinsulator Material, Larger Solder Contacts For Easier Termination. , Supply,Installtion,Testing&Commissioningof5pinxlrterminationplug Madeupofextrahightemperatureresistantinsulatormaterial,Larger Solder Contacts For Easier Termination With 120 Ohm Resister With 0.25Watt For Signal Termination. , Supply,Installtion,Testing&Commissioningofpvccopperunarmoured Flexiblefrlsinsulatedmulticorecable1100vgradeconfirmingtois694 Size 3Cx1.5 Sq Mm. , Supply,Installtion,Testing&Commissioningofpvccopperunarmoured Flexiblefrlsinsulatedmulticorecable1100vgradeconfirmingtois694 Size 12Cx1.5 Sq Mm. , Supply,Installtion,Testing&Commissioningofpvccopperunarmoured Flexiblefrlsinsulatedmulticorecable1100vgradeconfirmingtois694 Size 4Cx 4 Sq Mm. , Supply,Installtion,Testing&Commissioningofpvccopperunarmoured Flexiblefrlsinsulatedmulticorecable1100vgradeconfirmingtois694 Size 7Cx1.5 Sq Mm. , Supply,Installtion,Testing & Commissioning Of Fr Grade Dmx Signal 4 Core + Ground Shieldingcable With Ce Mark For The Signal Network. , Supply,Installtion,Testing & Commissioning Of Ms Perforated Tray Of Size 40 X 75 X 40Mm & 1.6 Mm Thickness Undergone Through 7 Tank Process With Variouschemicaltreatmenttokeepthemrustfree,Dulyepoxypolyester Powder Coated With Matt Black Texture Finish Along With Clamping Arrangement. , Supply,Installtion,Testing & Commissioning Of Ms Perforated Tray Of Size 40 X 150 X 40Mm & 1.6 Mm Thickness Undergone Through 7 Tank Process With Variouschemicaltreatmenttokeepthemrustfree,Dulyepoxypolyester Powder Coated With Matt Black Texture Finish Along With Clamping Arrangement. , Supply,Installtion,Testing & Commissioning Of Internal Earthing Copper Bare Conductor Of Size 14 Swg For Power Network Related To Work Coming Under Our Scope. , Drappery Works , Supply,Installtion,Testing & Commissioning Of Main Valance Bar, Length 15 Mtrs Made Using 40Nb, 48Mm Od Construction Arrangement 2Mm Thickness Undergone Through Various Chemical Treatment To Keep Them Rust Free And Duly Epoxy Polyester Powder Coated In Black Matt Texture Finish With Suitable Suspenders. , Supply,Installtion,Testing & Commissioning Of Main Curtain Track System 15 Mtrs Long, Center Parting With Overlap Of 0.9Mtr Arrangement Undergone Through Various Chemical Treatment To Keep Them Rust Free And Duly Epoxy Polyester Powder Coated In Black Matt Texture Finish With Below Specifications: • Heavy Duty Curtain Track Duly Epoxy Polyester Powder Coated In Black Matt Texture Finish. • 1.5 Hp Motor, 3 Phase Motor. • Gi Wire Ropes With Steel Core At Center. • Curtain Holding Trolliesplaced Uniformly At Specific Interval Of 200Mm /250 Mm Throughout The Track. • Diverter Pulley • Ms Yellow Passivized Routing Pulleys With Ball Bearing For Smoother Noiseless Movement 165Mm For Outer Diameter, 145Mm Diameter At Groove Base With 12Mm Pulley Thickness. • All The Materials Under Gone Through 7 Tank Process With Various Chemical Treatment To Keep Them Rust Free With And Duly Epoxy Polyester Powder Coated In Black Matt Texture Finish. , Supply,Installtion,Testing & Commissioning Of Mid & Rear Curtain Track System 15 Mtrs Long, Center Parting With Overlap Of 0.9Mtr Arrangement Undergone Through Various Chemical Treatment To Keep Them Rust Free And Duly Epoxy Polyester Powder Coated In Black Matt Texture Finish With Below Specifications: • Heavy Duty Curtain Track Duly Epoxy Polyester Powder Coated In Black Matt Texture Finish. • 1.5 Hp Motor, 3 Phase Motor. • Gi Wire Ropes With Steel Core At Center. • Curtain Holding Trolliesplaced Uniformly At Specific Interval Of 200Mm /250 Mm Throughout The Track. • Diverter Pulley • Ms Yellow Passivized Routing Pulleys With Ball Bearing For Smoother Noiseless Movement 165Mm For Outer Diameter, 145Mm Diameter At Groove Base With 12Mm Pulley Thickness. • All The Materials Under Gone Through 7 Tank Process With Various Chemical Treatment To Keep Them Rust Free With And Duly Epoxy Polyester Powder Coated In Black Matt Texture Finish. , Supply,Installtion,Testing & Commissioning Of Ms, Wing Frame Made Out Of 25X25mm Or Higher Size Made Of Ms Square Pipe With 2Mm In Thickness Undergone Through Various Chemical Treatment To Keep Them Rust Free And Duly Powder Coated In Black Matt Texture Finish With Below Specifications: • Wing Frame Size 5.5 X 1.5Mtr • 1.5Meter Wing Track Of 48X84mm With Grid Mount Brackets Made Of40x50x40mm C Track, • Pivotable 4 Wheeled Suspension Trolley, • Adjustable Floor Locking Screw Jacks With Rubber Grips, • Inverted 4-Wheeler Trolley With Flexi Adaptor Clamp, • Heavy Duty Wing Track To Be Laid For Minimum Length Of 1.5Mtr, Along The Width Of The Stage. • 360° Rotatable And Can Move In Unidirectional • All The Materials Under Gone Through 7 Tank Process With Various Chemical Treatment To Keep Them Rust Free With And Duly Epoxy Polyester Powder Coated In Black Matt Texture Finish. , Supply,Installtion,Testing & Commissioning Of Cyclorama Frame Arrangement Of Size 12 Mtr X 5 Mtr Undergone Through Various Chemical Treatment To Keep Them Rust Free And Duly Powder Coated In Black Matt Texture Finish With Below Specifications: • Heavy Duty Cyclorama Track Duly Epoxy Polyester Powder Coated In Black Matt Texture Finish To Use As Straight Cyclorama Track • Ms Fabricated Grid/Wall Mount Bracket Constructed Of C Track Of Dimension 40X50x40mm Duly Powder Coated To Hold The Cyclorama Track, • Ms Fabricated Tie Down Railing Cut Length 3 Mtr Duly Powder Coated To Keep The Cyclorama In Drum Tight Arrangement, • 2 Wheeler Trolley Placed Uniformly At Specific Interval Of 200Mm/250Mm Throughout The Track To Hold The Cyclorama Screen • Ms Powder Coated Leading Edge Pipe Of 25Nb, 33.4Mm Od, 2Mm Thickness To Keep The Cyclorama In Drum Tight Arrangement. • All The Ms Materials Under Gone Through 7 Tank Process With Various Chemical Treatment To Keep Them Rust Free With And Duly Epoxy Polyester Powder Coated In Black Matt Texture Finish. , Supply,Installtion,Testing & Commissioning Of Motor Cable Termination Box For Power Cable Termination At Grid Level. • Ce Certified Fc/Pg 11 & 13.5 Cable Entry Gland Required Nos As Per Cable Entry. • Ms Channel Arranging To Fix Grey Terminal Connector, Required Nos With Separation Plate And Each End Is Completed With Adding End Plate With End Cap. • Grey Terminal Connector With Each Line Having L1, L2, L3, E, 6 , 2 , 4 Indication For Each Line Incoming And Outgoing Cable Connectors (L1, L2, L3, E For Power Supply & 6 , 2 , 4 For Limit Switch Connection) • Box Door Must Be Made With Hingeable Door With Screw Lock. • Grid Mount Fixing Arrangement For Fixing On Grid Or Anchor Fastener For Wall/Floor Fixing • Ms Boxe Made Up Of 20Swg Crca Sheet Undergone Through 7 Tank Process With Various Chemical Treatment To Keep Them Rust Free, Duly Epoxy Polyester Powder Coated With Matt Black Texture Finish. , Supply,Installtion,Testing & Commissioning Of Ms Fabricated Combined 3 Way Motor Control Center Panel Cum Remote Control Panel For Curtain System Made Up Of 14Swg / 16Swg / 18 Swg Crca Sheet Undergone Through 7 Tank Process With Various Chemical Treatment To Keep Them Rust Free, Duly Epoxy Polyester Powder Coated With Matt Seaman’S Grey Texture Finish With Following Specifications. • 16A Tp Or Tpn Incomer. • Main Contactor Of 9A 240V 4 Pole Contactor With 04 -06A Over Load Relay For Safety • 24V 4 Pole Low Voltage Contactors • 240V / 24 V Step-Down Transformer For Low Voltage Contactors • All The Frls Pvc Isi Marking Cables Inside The Panel Routed Through Pvc Gray Color Cable Trough. • Red Color Mushroom Head Push Button For Emergency Stop • Yellow Color Reset Push Button • Master Sector Actuator Switch With 3 Position Up, Down & Off • Spring Return Selector Switchfor Each Hoist With Up & Down Indication. • All The Cables Inside The Panel Routed Through Pvc Gray Color Cable Trough. • Panel Including Wiring With Proper Earthing. , Main Valance Fabric : Supply,Installtion,Testing & Commissioning Of Fire Retardant Velvette Fabric100% (2 Times Of The Finished Dimension) Gathering As Per The Approved Patern And Colour, Not Less Than 300 Gsm, Duly Stitched Along Witheyelets. Size : 15 X 1.3 Meter , Main Curtain Fabric : Supply,Installtion,Testing & Commissioning Of Fire Retardant Velvette Fabric With Lining 100% (2 Times Of The Finished Dimension) Gathering As Per The Approved Patern And Colour, Not Less Than 300 Gsm, Duly Stitched Along Witheyelets. Size : 16 X 6 Meter , Rear Curtain Fabric : Supply,Installtion,Testing & Commissioning Of Fire Retardant Cotton Fabric 50% Gathering For As Per The Approved Patern And Colour, Not Less Than 250 Gsm, Duly Stitched Along With Eyelets. Size : 16 X 6 Meter , Frill Fabric :Supply,Installtion,Testing & Commissioning Of Fire Retardant Cotton Fabric 50% Gathering For As Per The Approved Patern And Colour, Not Less Than 250 Gsm, Duly Stitched Along With Eyelets. Size : 12 X 1.3 Meter , Wing Fabric :Supply,Installtion,Testing & Commissioning Of Fire Retardant Cotton Fabric 0% Gathering For As Per The Approved Patern And Colour, Not Less Than 250 Gsm, Duly Stitched Along With Eyelets. Size : 5.5 X 3.1 Meter , Cyclorama :Supply,Installtion,Testing & Commissioning Of Perforated Plastic Cyclorama Screen With Zero Gain, Off White, With Eyelets Along All Four Sides, Perforated Plastic Screen With Eyelets.Size : 12 X 5 Meter , Supply,Installtion,Testing & Commissioning Of Pvc Copper Unarmoured Flexible Frls Insulated Multicore Cable 1100V Grade Confirming To Is694 Size 4Cx 4 Sq Mm. , Supply,Installtion,Testing & Commissioning Ofpvc Copper Unarmoured Flexible Frls Insulated Multicore Cable 1100V Grade Confirming To Is694 Size 7Cx1.5 Sq Mm. , Audio Video , Supply , Installation , Testing And Commissioning Of Projector Laser Projetor 10000 Lumens With Suitable Lens & Ceiling Mount With Edge Blending Image Stiching Software , Supply , Installation , Testing And Commissioning Ofprojection Screen -Matte White 1.0 Gain . Approx Size 30 Ft X 12 Ft With Required Support Structure For Mounting. , Audio , Supply Of Front-Of- House Left And Right Clusters With A 14 Lf Driver Or Better And Multiple Mf/Hf Drivers (More Than 4), Biamplified 2 Or 3 Way Array Loudspeaker System; With Individual Module Free Field Frequency Range (-10Db) Of 55Hz - 18Khz Or Better & Continuous Power Handling Of >= 750W Lf + 150W Mf/Hf. The Loudspeaker Module Shall Have A Max. Spl (Peak) Of Mf/Hf>= 130 Or Better. It Should Have Horizontal Near Dispersion Pattern Of 70º Or Better, Vertical Dispersion Of The Array Shall Be 80 Degrees Or Better. , Supply Of Front-Of- House Left And Right Clusters With A 14 Lf Driver Or Better And Multiple Mf/Hf Drivers (More Than 4), Biamplified 2 Or 3 Way Array Loudspeaker System; With Individual Module Free Field Frequency Range (-10Db) Of 55Hz - 18Khz Or Better & Continuous Power Handling Of >= 750W Lf + 150W Mf/Hf. The Loudspeaker Module Shall Have A Max. Spl (Peak) Of Mf/Hf>= 130 Or Better. It Should Have Horizontal Near Dispersion Pattern Of 70º Or Better, Vertical Dispersion Of The Array Shall Be 80 Degrees Or Better. , Supply, Installation, Testing & Commissioning Of Oem Array Frames/ Hanging/ Mounting Arrangement For Suspension Of Upto 8-10 Array Modules Offered Above, Shall Offer Multiple Rigging Points For Achieving Desired Pitch Settings. , Supply , Installation , Testing And Commissioning Of Oem Couling Plate For Array Modules Offered Above. , Supply , Installation , Testing And Commissioning Of A Single 18 Subwoofer. The Louspeaker Shall Meet The Following Performance Criteria: Frequency Range (-10 Db) Of 29Hz - 300Hz. It Should Have An Ground Stack Position Sensitivity Of > = 98Db (1W/1M) Or More Delivering A Ground Position Max. Calculated Spl(Peak) Of >=133 Db; Nominal Impedance Of 4Ohm Or Higher And Continuous Power Handling Of 750W Or More.The Loudspeaker System Shall Be Comprised Of Abaltic Birch Plywood Enclosure With Standard Array Rigging Hardware For Cardioid As Well As Stacked Position. , Supply , Installation , Testing And Commissioning Of Custom Supsension For Subwoofers , Supply, Installation, Testing And Commissioning Of Two-Way 5.25-Inch Or Better High Spl Ip55 Rated Surface Mount Loudspeaker.The Louspeaker Shall Meet The Following Performance Criteria: Frequency Range (-10 Db) Of90hz - 18 Khz Or Better; Nominal Dispersion : 90°H X 80°V Or Better; Power Handling Of 400W Peak Or More; Sensitivity : 86 Db Or Better And The Max Spl: 116Db Peak Or More With Anominal Impedence Of 8 Ohms And Integral Multi-Tap Transformer With Selectable Tap Settings Of 10/20/40/80W@70V & 100V; Standard Wall Mount Brackets Shall Be Included , Supply, Installation, Testing And Commissioning Of Two-Way A Single 8-Inch Or Better High Spl Ip55 Rated Surface Mount Loudspeaker. The Louspeaker Shall Meet The Following Performance Criteria:Frequency Range (-10 Db) Of80hz - 18Khz Or Better; Nominal Dispersion : 90°H X 60°V Or Better; Power Handling Of 800W Peak Or More; Sensitivity : 92Db Or Better; Max Spl : 116Db Peak Or More With A Nominal Impedence Of 8 Ohms And Integral Multi-Tap Transformer With Selectable Tap Settings Of 10/20/40/80W@70V & 100V Standard Wall Mount Brackets Shall Be Included , Supply, Installation, Testing & Comissioning Ofpassive Coaxial Two-Way Point Source Loudspeaker With A Single 8-12 Lf Driver And Compression Driver With 1.7 Or Better Voice Coil. Frequency Range (-10Db) Of 75Hz - 20Khzor Better & Long Term Continuous Power Handling Of 150W Or Better. The Loudspeaker Module Shall Have A Max. Spl (Peak) Of 128 Or Better. It Should Have Horizontal Dispersion Pattern Of 110º Or Better, Vertical Dispersion Of The Loudspeaker Shall Be 60 Degrees Or Better. The Loudspeaker Shall Be Enclosed In A Multi Angle Baltic Birch Plywood Enclosure With Perforated Steel Grille And Monitor Tilt Back Angle Of 35 Degrees. , Sitc Of Digital Audio Conferencing Processor With At Least 12 Mic/Line Inputs & 8 Analog Outputs, 24 Bit A-D And D-A Convertors; Sampling Rate : 48 Khz;Thd : < 0.002 % ; Channel Separation (Crosstalk) : < 108 Db ; Frequency Response 20 Hz - 20 Khz ; Signal-To-Noise Ratio 90 Db ;Dynamic Range > 115 Db; 5 Control Inputs And Outputs; Rs-232 And Ethernet Port For Third Party Control And Monitoring; 32X32 Or More Bidirectional Audio Networking Ports, Shall Include Usb Audio As Standard Feature. Inbuilt Dsp Features Like Conference Room Routers,Input Equalizers, Router, Band Pass Filter, Output Equalizer, Delay, Limiters, Gates , Source Selectors Etc. Shall Support At Least 15 Remote Zone Controllers , Supply, Installation, Testing & Commissioning Of Programmable Audio Dsp Controller With Display And Programmable Encoder Knobs. Multiple Programmable Settings Configurable Over Ethernet. Source Selection And Volume Controls ; Supports Upto 256 Programmable Functions Shall Include Any Accessory To Make The System Functional. , Supply , Installation , Testing And Commissioning Of Digital Amplifier With Max Output Power Of 4X1200w@4-8Ohms, 70V Or 100V Or Bridged Mode Output Power Of 2X3000w@4Ohms. Frequency Response Of 20 Hz - 20 Khz, Snr Of >110 Db(A And Thd+N < 0.1%. With Multiple Channel Metering Ledand Attenuation Controls. Peq, Band Pass, Spkr Eq, Limiter, Delay. Maximum Input Level 20 Dbu. 4 Digital Channels Via Oem, With Euroblock, 8-Pin Connectors For Analog Outputs. Software And Hardware Controlled. Sample Rate 24-Bit, 44.1 Khz – 192 Khz. , Supply , Installation , Testing And Commissioning Ofclass D Configurable Amplifier With Total 2 X 600W Output Power Or Better Across 2 Outputs, 4/8Ohms, 70/100 Voltor Mixed Use Operation; Frequency Response : 20Hz - 20Khz For Lz Mode ;Thd <0.04% At Rated Output , Supply , Installation , Testing And Commissioning Of Class D Configurable Amplifier With Total 2 X 1000W Output Power Or Better Across 2 Outputs, 4/8Ohms, 70/100 Voltor Mixed Use Operation; Frequency Response : 20Hz - 20Khz For Lz Mode ;Thd <0.04% At Rated Output , Supply , Installation , Testing And Commissioning Of Of Class D Configurable Amplifier With Total 4 X 300W / 2 X 600W Output Power Or Better @ 4/8Ohms, 70/100 Voltor Mixed Use Operation; Frequency Response : 20Hz - 20Khz For Lz Mode ;Thd <0.04% At Rated Output Complete With Standard Accessories As Required. , Supply , Installation , Testing And Commissioning Of Wired Handheld Microphone Vocalcomplete With Standard Accessoriesas Per The Tender Specifications Sennheiser E845 Or Equivalent Ofshure/Akg , Supply , Installation , Testing And Commissioning Of Wired Instrumental Microphone Complete With Standard Accessoriesas Per The Tender Specifications Sennheiser E604 Or Equivalent Ofshure/Akg , Supply , Installation , Testing And Commissioning Of Wireless Uhf Handheld Microphone Setcomplete With Standard Accessories As Per The Tender Specifications Sennheiser Ew-100-G4-835 Or Equivalent Of Shure/ Akg , Supply , Installation , Testing And Commissioning Of Wireless Uhflapel/ Head Gear Microphone Set Complete With Standard Accessoriesas Per The Tender Specifications Sennheiser Ew-100-G4-Me2 Or Equivalent Of Shure/ Akg , Supply , Installation , Testing And Commissioning Of Gooseneck Microphone With On/Off Complete With Standard Accessories As Per The Tender Specifications Sennheiser Meg14- 40B+Mat 133S Or Equivalent Ofshure/ Akg , Supply , Installation , Testing And Commissioning Of Hanging Microphone Complete With Standard Accessories As Per The Tender Specifications Akg Chm99 Or Equivalent Of Sennheiser/ Shure , Supply , Installation , Testing And Commissioning Of Boundry Microphonecomplete With Standard Accessories As Per The Tender Specifications Akg Or Equivalent Of Sennheiser/ Shure , Supply , Installation , Testing And Commissioning Of Antenna System Complete With Standard Accessories As Per The Tender Specifications Sennheiser/ Shure / Akg , Supply, Installation, Testing & Commissioning Of Digital Audio Mixer With Oem Interface. , Supply, Installation, Testing & Commissioning Of Io Stage Box Compatible With Digital Audio Mixer. , Supply Of Xlr Floor Box Complete With All Standard Accessories , Supply, Installation, Testing & Commissioning Of Full Range Ip55 Rated Indoor/Outdoor Surface Mounted Music And Pa Loudspeaker. The Loudspeaker Shall Meet The Following Performance Criteria: Usable Frequency Range (-10Db) Of 83Hz To 19Khz; Power Handling Of 64 Watt Peak; Nominaldispersion Of 130°(H) × 130°(V); Sensitivityof 85 Db Spl And Max Spl Of 103 Db Spl Peak; Nominal Impedance Of 16 Ohms And Integral Multi-Tap Transformer With Selectable Tap Settings Of 2/4/8/16W@70V & 100V.The Loudspeaker System Shall Be Comprised Of A 2.25-Inch Woofer; Enclosed In Engineered- Plastics And A Powder-Coated Tamper- Resistant Steel Grille. Ul-1480 Rated And En54-24 Compliant For Life Safety/Va Applications. Shall Be Packed In Pairs. , Supply, Installation, Testing And Commissioning Of Intregrated Stereo Class D Amplifier With Output Of 2 X 50 W @ 4 Ohms, 2 X 25 @ 8 Ohms; Frequency Response Of 40Hz To 20Khz; Thd <0.3%; Shall Include Priority Override And Fire Alarm Interface And Necessary Loudspeaker Eqs. , Supply, Installation, Testing & Commissioning Of Full Range Ip55 Rated Indoor/Outdoor Surface Mounted Music And Pa Loudspeaker. The Loudspeaker Shall Meet The Following Performance Criteria: Usable Frequency Range (-10Db) Of 83Hz To 19Khz; Power Handling Of 64 Watt Peak; Nominaldispersion Of 130°(H) × 130°(V); Sensitivityof 85 Db Spl And Max Spl Of 103 Db Spl Peak; Nominal Impedance Of 16 Ohms And Integral Multi-Tap Transformer With Selectable Tap Settings Of 2/4/8/16W@70V & 100V.The Loudspeaker System Shall Be Comprised Of A 2.25-Inch Woofer; Enclosed In Engineered- Plastics And A Powder-Coated Tamper- Resistant Steel Grille. Ul-1480 Rated And En54-24 Compliant For Life Safety/Va Applications. Shall Be Packed In Pairs. , Supply , Installation , Testing And Commissioning Of Of Class D Configurable Amplifier With Total 2 X 600W Output Power Or Better Across 2 Outputs, 4/8Ohms, 70/100 Voltor Mixed Use Operation; Frequency Response : 20Hz - 20Khz For Lz Mode ;Thd <0.04% At Rated Output , Supply , Installation , Testing And Commissioning Of 100 Volt Line Analog Volume Controllers. , Control , Supply , Installation , Testing And Commissioning Of Control Processor , Supply , Installation , Testing And Commissioning Of 48 Port 1 Gig Poe+ Network Switch , Supply , Installation , Testing And Commissioning Of Ipad / Tablet , Supply , Installation , Testing And Commissioning Of Of Universal Hdmi Adapter Ring With * 1 Apple Certified Adapter Lightning (M) To Hdmi (F) And Lightning (F) To Power Device (Md826am/A) * 1 Apple Certified Adapter Usb C To Hdmi W/Usb A Port (Mj1k2am/A) * 2 Security Clamp To Attach Apple Adapters To Dl-Ar System (Dl- Ap) * 1 Base Security Clamp, Cable And Hardware For Dl-Ar System (Dl-Cl) , Supply, Installation, Testing & Commissioning Of 2 Core 16 Awg/1.5 Sq Mm, Twisted, Unshielded Speaker Cable With Stranded Annealed Bare Copper Conductors, Semi-Rigid Pvc Insulation, Nec Cl3r, Cec Cmg, Rohs Compliant , Supply, Installation, Testing & Commissioning Of 2 Core 14 Awg/2.5 Sq Mm, Twisted, Unshielded Speaker Cable With Stranded Annealed Bare Copper Conductors, Semi-Rigid Pvc Insulation, Nec Cl3r, Cec Cmg,Rohs Compliant , Supply, Installation, Testing & Commissioning Of 2 Core 12 Awg/4 Sq Mm, Twisted, Unshielded Speaker Cable With Stranded Annealed Bare Copper Conductors, Semi-Rigid Pvc Insulation, Nec Cl3r, Cec Cmg, Rohs Compliant , Supply , Installation , Testing And Commissioning Of Of 4 Pair Shielded/Foiled Tia/Eia-568-C Category 6A Cable With 23Awg Or Better Solid Annealed Bare Copper Conductors, High-Density Polyethylene Insulation, Flame Rated Pvc Jacket, Overall Aluminum/Poly Foil Shield With Drain, Nec Cmr, Cec Cmr Ft4, Rohs Compliant. , Supply , Installation , Testing And Commissioning Of Of 2 Core Twisted, Shielded Balanced Audio And Control Cable With 22Awg Or Better 7 Strand Annealed Bare Copper Conductors, Semi-Rigid Pvc Insulation, Riser Rated Pvc Jacket. Ul 444, Ul 13 Cmr Rated , Supply , Installation , Testing And Commissioning Of Of 15 High Speed Hdmi With Ethernet Cable For 3D, 4K, Deep Color Applications And Installations, 18.0Gbps Bandwidth To Support 4K60 4:4:4, Shall Support Arc,And All Hdcp Levels, Hdr Certified By Hdmi Atc,Rohs, Reach, And Taa Compliant, , Supply , Installation , Testing And Commissioning Of De15 Male Plug To De15 Male Plug Video Connectivity 3.5Mm Male Plug To 3.5Mm Male Plug Stereo Audio Video And Sync On 26 Awg High Resolution Coaxial Cables Id Bit Communications And Edid Pin 9 On 22 Awg Cabling Full 15-Pin Vesa Edid And Id/Ddc Compliance Double Shielded Foil And Braid Overall Shield Thumbscrew For Ease Of Installation And Retention 22 Inch Audio Leads For Routing Ease And Convenience Nec Cl2, Csa Type Awm I/Ii A/B Ft4, Rohs Compliant. , Supply , Installation , Testing And Commissioning Ofof 6 High Speed Hdmi With Ethernet Cable For 3D, 4K, Deep Color Applications And Installations, 18.0Gbps Bandwidth To Support 4K60 4:4:4, Shall Support Arc,And All Hdcp Levels, Hdr Certified By Hdmi Atc,Rohs, Reach, And Taa Compliant, , Supply , Installation , Testing And Commissioning Of Various Types Of Cables & Connectrs Packages , Supply , Installation , Testing And Commissioning Of 12 U Rack , Chair , Chair(Comfort) Supply,Installation,Testing & Commissioning Of Auditorium Ecoustic Chairs, Fixed As Per Drawing And Site Condition With Fixed Back And Tip-Up Mechanism And With Clients Approved Colour Selective Fabric (Fabric Shall Be Fire Retardent) As Per Chair Sample Submited. Complete With All Accessories And Fixing With Four Number Anchor Fasteners Of Hilti/Fischer Make. Seating To Be Fixed As Per Layout In Design Drawing. Complete As Per Specifications, Sample Chair Approved As Per Comfort And Fabric Color By The Architect And Client. Size Options : 510 Mm Ctc. M.S. Tubular Structure With U Channel. 3 Mm Foam Laminated Fabric. Moulded Pu Foam 48 To 50 Density. Ppcp With Cup Holder Handle With Cushion Same Colour Fabric. Ppcp Tray Cover For Seat & Back. Black Powder Coating Surface.All Completed Upholstery Units Shall Be Made Fire Reteardent To Local Fire Regulation Standards.Performance Of Flameproof Materials For Clothing &Other Purposes.Pull Load Test To Be Performed. Front Two Rows Shall Be Vip Seats With Cushionsand Bigger Size As Per Architect Specs. , Annual Maintenance Contract For 10 Years From Completion Of Defect Liability Period For Stage Lighting, Audio Video, Drapery & Chairs, Etc.
Contract Date: Mar 24, 2026 Contract Value : 7.19 Crore
Local Bodies No of Bidders 3
Maharashtra View Result →
35.
Educational and Research Institute #9832816 AOC
PROCUREMENT OF MACHINERIES, INSTRUMENTS, TOOLS AND EQUIPMENTS ETC. RELATED TO ELECTRICAL ENGINEERING AND ELECTRONICS AND TELECOMMUNICTION ENGINEERING LABORATORIES AND WORKSHOPS OF MATHABHANGA GOVERNMENT POLYTECHNIC, MATHABHANGA, COOCH BEHAR, WEST BENGAL- 1 ANALOG ELECTRONICS LAB-I (3RD SEM) 2 50 MHz Dual Channel CRO• Automatic Measurements of Signal Parameters like .Pk-Pk, Average, Max. , Min., rms, top etc. Voltages and Frequency, Period,Width,Duty Cycle, Rise Time, Fall Rime • Waveform and Set up storage facility.• Colour Display. • Advanced features like sequential acquisition of up to 1000 trigger events should be possible.• Standard USB Host & Device Connectivity. • Standard 23 Automatic Measurement andMath Function Including FFT.• Education student Lab guide and professor slide set.DETAILED TECHNICAL SPECIFICATIONS:-a)No. Of Channels:2b)Bandwidth :50 MHzc)Maximum Input:400 V (peak ac + dc) d) Sample Rate :1 GSa/sece)Waveform Update Rate : 400 Waveforms/secf)Memory : 16 Kpts/Ch.g)Time Base : 5nsec / div. To 50 sec./div.h) Resolution : 8 bitsi) Display: 5.7 inch Colour QVGA TFT LCD Display.j)Trigger Modes: Force, Edge, and Video, Pulse width.k) Built In Interface : Standard USB 2.0 (Host and Device)l)Power Supply: 230 V AC Supply, 50 Hz. 3 Function Generatori)Itshould be a waveform / function generator which can be upgraded to an arbitrary waveform generator . It may also have the feature upgrade the frequency of operationii) Should have low harmonic distortion and jitter.DETAILED TECHNICAL SPECIFICATION:--• Frequenc : 1Hz. to 20 MHz for Sine , Square and PulseWaveforms and 1 Hz. to 20 MHz. for Noise• No. of Channels: 1• Frequency Resolution : 1Hz.• Amplitude : 1 mVpk-pk to 10 v (pk - pk) in 50 ohms. • Duty Cycle for Pulse : 0.01 % to 99.99 %• Standard Waveforms: Sine,Square,Ramp,Pulse,Triangle,•Operating Modes: Continuous,Modulate,. .• Modulation Types: AM,FM,PM,FSK,BPSK,PWM• AM : Source both Internal & External, Depth 0 to 120 %With 0.01 % resolution.• FM : Source both Internal & External, Deviation 1Hz to 15 MHz• PM: Source both Internal & External, Deviation 0 to 360 deg C.• PWM : Source both Internal & External. Deviation 0 % to 100 %.• Power Supply : 230 v,50 Hz. ac. 4 Digital MultimeterDC Voltage:400mV to 1000V , AC Voltage: 400mV to 1000V,DC Current: 4mA to 10A, AC Current: 4mA to 10A, Resistance: 100 ohm to 40Mohm, Resistance: 100 ohm to 40Mohm,Capacitance: 4nF to 200µF, Duty Cycle: 0.1% to 99.9%, Frequency: 10Hz to 10MHz, Temperature: 20oC to 750oC,Transistor Test: Yes (for NPN & PNP), Diode Test: Yes, Continuing Buzzer: Yes, Power Supply: 9V, Manual and Auto ranging,Display: 4½ Digit 5 To study the V-I characteristics of UJT Trainer kitVariable DC Power Supply 1.2V to 12V/500m,A DC Power Supply for DPM 5V/500m,A UJT (2N2646) UJT Characteristics UJT Relaxation Oscillator with two different Timing Capacitors ,DigitalMeters for Measuring Voltage and Current ,Set of Patch Chords & User Manual 6 To study the input and output characteristics and to find the h-parameters of a BJT for : —(a) C-E configuration,(b) C-C configuration,(c) C-B configurationHARDWARE SPECIFICATIONS :Dual Variable DC Power Supplies 0V to 12V/500mA and0V to 15V/500mA DC Power Supply for DPM 5V/500mAIndependent Base Limiting Resistors - 2 Nos.(low value) Independent Collector Resistor - 1 No. Transistor( NPN Type SL100) .All Inputs/Outputs through 2mm Sockets set with provision of Digital Multimeter for measuring input and output. 7 ANALOG ELECTRONICS LAB-II (4TH SEM) 8 Feedback Amplifier Trainer12 V DC supply with +/- 10%accuracy,configurable circuit,Inbuilt sine wave generator with frequency range 10 Hz to 10 KHz rangeand Amplitude variation 10mV to 4V, NPN transistor. Voltage Series & Shunt and Current Series & Shunt configurable operation. 9 Oscillator Trainer KITi) Hartley, Colpitt ,Wien Bridge Oscillator Trainer kit : i) NPN Transistor ii)On boardoscillator section,separate tank circuit (iii)Biasing Voltage :+12 V , -12 V ,+12V SMPS Adaptor provided with the trainer for power supply.Designed by considering all the safety standards. Provided with an extensive manual.Power Supply to Kit: 230VAC,50Hz, All interconnections are made using 2mm banana Patch cords 10 To determine the following characteristics of op-amp: —a) input offset voltage, b) slew rate, c) non-inverting gain, d) inverting gain e) adder, f) subtractor, g) differentiator, h) integratorandi) voltage followerTo adjust offset null, setup the closed loop amplifier using IC741 op-amp also to (a) dc gain (b) ac gain. The set complete with +/-12V DC regulated power supply with milli voltage source, Null arrangement and 2V/20V dual range digital voltmeter , In built sine wave,triangular wave & square wave Generator of1 KHz, 15V Vpp (approx.), DC Power Supply : 0 - 5 V (vary through (2No.) rotary switch for specific voltage level 11 DIGITAL ELECTRONICS LAB (3RD SEM) 12 Complete setup to implement encoder, decoder ,multiplexer andde-multiplexer5V D.C. at 100mA, IC regulated power supply,21 Input Switches for data input,IC For Multiplexing 74150 is provided on board with Combinational Circuit, IC For Demultiplexing 74154 is provided on board with Combinational Circuit, One Not Gate is provided on board using 7404 ,16 Output LEDs with driver circuit to observe the output of Multiplexer Demultiplexer, A Pulser to provide the pulses manually for triggering,230 V ±10% at 50 Hz A.C. Mains,necessary patch cords and user mannuals. 13 Complete setup to design / construct parity generator, checker andcomparatorDC Regulated Power Supply 5 VDC/150 ma,5 SPDT switches provided for selecting logic ‘1’ & logic ‘0’,2 output indicators,Sufficient no of 4mm Patch Cords for Interconnection,Power Cords 230v, 50Hz,necessary patch cords and user mannuals. 14 Complete setup to design / construct binary synchronous and asynchronous counterTrainer kit for binary Synchronous and Asynchronous counter. with power supply, display unit, patch cords, manuals and necessary IC. 15 Digital I.C TesterUniversal IC tester: 40 pin DIP ZIF socket, 50 cherry keys Key pad and 16 X 2 LCD Display, suitable for testing of Analog IC, Digital IC and 7-segment display. 16 A/D & D/A Converter TrainerFEATURESAnalog To Digital Converter• 8-bit descrete ADC•12-bit monolithic ADC IC•On-board signal generator with adjustable amplitude levels•On-board LED bank to observe digital outputs•Power supply : +5V, ±12V GND•Interconnection is provided by 2mm connectors•Experimental manualDigital To Analog Converter•8-bit binary weighted resistors DAC•8-bit ladder type D to A converter•8-bit D to A converter using monolithic IC•Simple construction using Op-Amp and resistors•Onboard switches are provided for digital pattern generation•8-bit digital inputs ranges from 00 to FF•Variable frequency counter to study the settling timeSPECIFICATIONS•8-bit binary weighted and 4-bit ladder type DAC are constructed using discrete components•8-bit monolithic DAC having settling time in the range of ns, wide power supply range, low power consumption, full scale error ± 1LSB•8-bit digital ramp ADC constructed using discrete components•12-bit monolithic ADC having conversion time in the range of μs, industry standard pin out, wide input range•8 onboard switches to provide digital inputs to DAC•8-bit counter running on external clock frequency to study settling time of DAC• Built inlow frequency clock generator•1 KHz sine wave with adjustable amplitude level•Onboard variable DC voltage source for studying unipolar and bipolar modes of ADC •12 output LEDs to observe ADC outputs•ADA operates on DC power supply (+12V,-12V,+5V and GND)•Interconnection is provided by standard 2mm connector•Extensive experimental manual is provided with the kit EXPERIMENTSAnalog To Digital Converter• To study and measure resolution of ADC•To measure the conversion time of the ADC•To study full scale adjustment for unipolar and bipolar signals•To study the working of ADC 17 NETWORK ANALYSIS LAB ( 3RD SEM) 18 To study the series and parallelresonant circuitIndependent Resistors - 3 Nos. ,Independent Capacitors - 3 Nos.,Tapped Inductance. All Inputs/Outputs through 2mm Sockets Set of Patch Chords & User ManualWITH SIGNAL GENERATOR, COUNTER, DIGITAL METERS FOR INPUT & OUTPUT and user manual 19 To test and to measure the cut –off frequencies of the following: —(a) constant k-type low pass filter;(b) constant k-type high pass filterTwo Independent Passive LC Filter Networks (LPF & HPF) All Inputs/Outputs through 2mm SocketsSet of Patch Chords & User Manual 20 To study standing wave pattern for a transmission line of finite length with:(a) open termination,(b) shorted termination andmatched termination. 2.To measure the attenuation constant and phase shift constant for matched terminationTransmission Line Trainer Features:* 30-300 Mhz sweep source with detector* Calibrated attenuator* Displays standing waves/maxima-minima on CRO* Uses actual coaxial lines rather than simulated ones.* Impedance matching.* Measures VSWR, reflection coefficient, characteristic impedance, velocity of propagation, dielectric constant and signal attenuation in TDR.* Measure parameters of 50, 75 and 300 Ohms cables* Study Time Domain Reflectometry.* Study location and nature of discontinuities,Open/short, mismatched terminations, etc.* Offers a complete view of the transmission line in analog and digital domains, which is essential for complete understanding of transmission line behavior.Technical Specifications:A. Frequency Domain AnalyzerFrequency range : 30-300 MHz typical LCD Display. Level : 100mV p-p Attenuator 50 Ohms : 0.5, 1, 2,4, 8,15 dB,Output Impedance : 50 Ohms Scope out : X-Y output to scopeB. Resistive Impedance Analyzer ,Characteristic Imp. : upto 800 ohms ,Display : LCD C. Time Domain ReflectometerPRR Short range : 10MHz typical,Pulse width : <10ns typical, PRR Long range : 100KHz typicalAmplitude : 1V nominal, Output Impedance : 50 OhmsAccessories:Lengths of 50 ohms and 75 ohms coaxial cable, 300ohms, parallel line, lossy line, Tee connectors, ,Standard load of 50and 75 ohms, Various capacitive and inductive loads, shorts, Balun 1:1 & 1:4, Operating manual, Mains cord 21 COMPUTER PROGRAMMING LANGUAGE LABORATORY (3RD SEM) 22 Computer Programming Language LaboratoryTURBO C++ Software 23 MICROPROCESSOR LAB (4TH SEM) 24 8085Microprocessor Trainer KitHigh performance 8085A CPU operating at 3 MHz.16 K powerful monitor FIRMWARE expandable to 32 K. 64 K user RAM. Expanded RAM accessible using bankWrite protect facility for RAM. 3.6 V Ni-Cad battery back up. Versatile Keyboard/Display controller using 8279. 24 highly reliable dual function keys. 6 digit seven segment LED display.Parallel I/O lines available through two 8255 chips. Serial I/O through 8251 USART, with on-board level shifters 1488,1489.Programmable communication parameters. Built-in audio cassette interface.3 channels of 16 bit timer/counters from 8253.Powerful 8085 interrupt capabilities. On-board EPROM programmer with ZIF socket for programming 2716 to7512 EPROMs and various EEPROMs. Normal and intelligent programming modes.On-board ADC,DAC, opto-isolator, reed relay and miniature speaker. On-board logic probe.Single stepping, break pointing and machine cycle single stepping facility. Monitor functions can be called through software interrupts. Large collection of application software provided. All address, data and control lines from the CPU, buffered and brought out on 50 pin connector. Additional Stepper motor of specification:Shaft type: 5 mm DCurrent rating: 1200 mA2Voltage rating: 4 VHolding torque: 44 oz·inSteps per revolution: 200Resistance: 3.3 Ohm2Inductance per phase: 2.8 mHNumber of leads: 6Lead length: 30 cm 25 Microprocessor 8086 Trainer KitINTEL 8086CPU AT 4.77 MHZ CLOCK SPEED,16KB for monitor EPROM upgradable to 64kb16KB RAM expandable to 64KBBattery backup provision for RAM upto 64KB16 x 2 (or) 20 x 4 Alphanumeric LCD display101 keys IBM compatible keyboard24 TTL I/O lines brought out to two nos., of 26 pin FRC connector1 number of standard RS232C compatible serial port brought out to a pin D type male connector.3 channel 16 bit counter/timer using 8253.Fully buffered address data and control signals terminated at a 50 pin header(VXT BUS) for interfacing VBMB seriesof experiment boards and bus expansion.8 no’s of interrupt lines are terminated at a 10 pin connector.Kit operates with a single +5V/DC supplyThe kit and the power supply are mounted on a attractive light gray color fiber glass cabinet with fiber glass top cover.Built-in line assembler & DisassemblerPowerful debugging monitor to develop user program. 26 ELEMENTARY COMMUNICATION ENGG. LAB 27 To study the amplitude modulation and demodulation Ttrainer kit Features of Amplitude Modulation and Demodulation Trainer:On-board message signal with variable Amp/Freq On Board carrier signal with variable Amp/Freq AM Modulation using MC 1496 IC Demodulation using Diode Detector and LPF,6th Order LPF,Op Amp Based Variable AmplifierInternal Power Supply +5V , +12V/ 500 mATechnical Specification :Message Signal:Sine wave Frequency 100 Hz to 2.8 KHz, Amplitude 0 to 3VCarrier Signal: Sine wave Frequency-28 KHz to 108 KHzAmplitude 2V,Modulation : Balanced ModulatorAmplifier : Op Amp BasedDemodulation : Diode Detector & LPFLow Pass Filter : 6th Order LPFSupply Voltage (Board) : +12V, +5V / DCSupply current : 100 mA (Minimum)Input Voltage : 230 V/ 50 Hz ACInterface connectors : 2mm socket 28 AM/FM Radio Receiver kitFrequency range: 400KHz ~ 1.5MHzIntermediate frequency: 455KHzInputs: RF signalOutput IF frequency: 455KHz adjustableIF filter: Dual tune LC, RF amplifier with variable gain ,Mixer (frequency converter),Local oscillator:Output Signal: Sine waveFrequency range: 400KHz ~ 1.5MHz ,Amplitude: Adjustable from 0Vpp ~ 2VppOutput impedance: 50 Ohm ,1st and 2nd IF amplifierCentral frequency: 455KHz, Load impedance: Variable R-L-CGain: 40db with automatic gain control, Diode envelope detectorDetection of the envelop with variable RC filter. Audio output:Amplifier with audio jack, Audio amplifier gain: 26Db, Receiving media :MW coil antennaFM radio receiver, Reception range: 88MHz ~ 108MHz with continuous tuningTuning circuit: Using GANG capacitorIntermediate frequency: 10.7 MHz with ceramic filterEXPERIMENTS:Study of double sideband AM reception using envelope diode detector,Study of single sideband AM reception using product detector,Study of image frequencies,Study of adjustment of receiver tuned circuits,Voice reception using DSB/ SSB AM receiver (super heterodyne receiver)Effects of switch faults FM detection output level: 77.5Vrms (typical)FM detection output distortion factor: 0.3% (typical)Audio amplifier: Gain up to 46DbReceiving media: Adjustable telescopic antennaPower supply: -12V,+12V,+5V,GNDOutput volume regulation, output load impedance of 8 OhmEXPERIMENTS AM radio receiverTo study AM radio receiverTo study of image frequencies for AMFM radio receiverTo study FM radio receiverTo measure the frequency response of Audio amplifier 29 Pulse code Modulation and Demodulation system trainerInbuilt variable DC and 1 kHz AC Modulating Signals, Facility for applying external AC or DC Modulating Signal, Modulating circuit consists of a Positive Clamper, Sample and Hold (S and H), Analog to Digital Converter (ADC), Parallel to Serial Converter and Control Signal Generator, Observation of binary coded analog information by the LED status for both Modulation and Demodulation, PCM Modulation technique using IC, Built-in Pulse Code Demodulation circuit using a Serial to Parallel Converter and Parallel Shift Register DAC, Low Pass Filter for both AC & DC, Observation of Modulated & Demodulated waveform, Provision to monitor output on CRO, Clock to be provided from the Pulse Code Modulator to Demodulator circuit, Built-in IC based DC Regulated Power Supply with indication for power ON & fuse, 4 mm Patch Cords – 4 nos, Supply required 230V, 50 Hz and 1 phase AC, Comprehensive instruction manual complete with theory and operating details. 30 Frequency Modulation andDemodulation kitFM Modulators :Audio Oscillator : Sine wave (10Vpp adjustable) Frequency (300 Hz - 3.4 KHz) FM Modulators : 3 nos. • Reactance Modulator : Carrier Frequency - 455 KHz (± 3KHz) Varactor Modulator : Carrier Frequency - 455 KHz (± 2KHz) VCO Based Modulator : Carrier Frequency - 10 KHz - 200KHz (adjustable) ,Mixer / Amplifier adjustment FM Demodulator:Detuned Resonant DetectorQuadrature DetectorFoster-Seeley DetectorRatio DetectorPhase-Locked Loop Detector (IC HEF4046 based)Phase-Locked Loop Detector (IC LM565 based), Low Pass Filter : 3.4 KHz Cut off Frequency Amplifier (with adjustable gain) 31 DPCM & ADPCM MODULATION / DEMODULATION KITDPCM & ADPCM MODULATION / DEMODULATION KITOn Board Signals:. Frequency: 500KHz, Amplitude: 0 to 4 v pp 32 CONSUMER ELECTRONICS LAB (4TH SEM) 33 Black & White TV Trainer kit with provision of fault findingSystem: CCIR-B, 625 lines, Power supply :230V Ac, 50 Hz, Regulation range170v Ac to 270v Ac.,Power consumption :70 watts,Gain Limited sensitivity:55 dB for Video & 25 dB for AudioSound output :2.0 watts maximum. Screen size :20 Diagonal. Channel :VHF 2 to 12, UHF 21 to 68,S-band and Hyper-band. Isolated shockproof chassis. Sections:Electronic tuner, VideoI.F Section, Sound I.F, Video amplifier, Horizontal oscillator, Horizontal driver and EHT, Verticaloscillator, and output, S.M.P.S power ,Controls: Volume, tone, Brightness, contrast. Distortion :10 to 15% in Live program due to expanded P.C.B. All parts are soldered on Tags on SINGLE PCB of size 19x15” with complete circuit diagramSCREEN PRINTED in different colors with FAULT CREATING FACILITIES to create more than 25 faults. Standard Accessories : 1. Frame with PCB mounting.2. Picture tube fitted in wooden cabinet 3. A Manual having 20 practical. 34 DTH TV and SET TOP BOX TRAINER KITPower supply 230 V ,50 Hz, Input frequency: KU Band, Output frequency: 950-1450 Mhz.Noise temp: 35 degree,DISH ANTENA ,LNBIF FREQUENCY: 70 MHz 35 Colour TV Trainer with provision of fault findingStandard : CCIR-B-PAL-G, 625 Lines Channels : 230, 2 - 4 VHP I (VL), 5 - 12 VHP III (VH), 12 - 100 : BAND IV & V, else : S BAND & HYPER BAND Picture Tube Size : 36 cms. Diagonal RF Input Impedance : 75 W (Ohm) 36 DIGITAL & MICROWAVE COMMUNICATION ENGG. LAB 37 Spectrum AnalyzerFrequency range:9 KHz to 26.5 GHz,Phase noise :-102dBc/Hz, Max third order dynamic range, 1 GHz: 111dB, Displayed average niose level,1GHz:-163dBm,Standard attenuator range/step:50dB/10dB,70dB/10 squaredb,Overall amplitude accuracy:+/- 0.50dB 38 Antenna Trainer 86 - 860 MHZSPECIFICATIONS:Radiation pattern plotting software• Stepper motor controlled receiver stand.Antenna Measurement System:RF Source•Source types :PLL Synthesized with integrated VCO• Frequency range :100MHz to 3GHz• Dynamic range :85dBm• Transmitted power min:-50dBm• Transmitted power max:+5dBm • Impedance :50W / SMA RF Detector• Detector type: logarithmicdetector• Frequency range : 1MHz to 8GHz• Resolution: 0.1dB• Dynamic range : 85dB (±3dB)• Noise level : -90dbm• Impedance: 50W /SMA• Representation of RF level : dBmDisplay•128x64 Graphic LCD Display with backlit. Keypad•15 Key Membrane Keypad for user entry.Stepper motor controller•1.80 Resolutions.List of Standard 22 Antenna Suppliedwith the setupWire Antenna1.Monopole Plane base ground2.Dipole (2nos.) 3.Yagi4.Folded Dipole 5.Vee Dipole6.Rectangular Loop 7.HelicalMicrostrip Antenna 1.Planar Dipole 2.Planar Monopole3.CMSA 4.TMSA5.2X1 ARRAY 6.Annular ring7.Chip Antenna8.RMSA9.RMSA- Circular PolarizedAperture Antenna 1.E- Horn2.Open ended Waveguide Rectangular Array Antenna 1.Broadside Array2.Collinear ArrayReflector Antenna 1. Corner reflectorSOFTWARE• Radiation pattern plotting and analysis software suitable for windows environment Antenna PositionerThe Transmitter and Receiver Antenna stand is made of special material which is inhert to EM frequency and it has engraved height and angle scale on It. It has facility to adjust the height and level. Universal plug and fix Antenna mounts are provided to hold the antenna assembly in vertical and horizontalorientation for co and cross polarization.ACCESSORIES • SMA (M) to SMA (M) 50W flexible cable : 02nos• USB cable ( Male A to Male B): 01no• 3 Pin 6 Amp Power chord: 01no • Manual : 01no • Software on CD: 01no EXPERIMENTS• Measure the variation of field strength /inverse square law• Prove the reciprocity theorem of antenna• Plot Radiation pattern of WIRED Antenna Omni directional antenna• Plot Radiation pattern of all Aperture Antenna• Plot Radiation pattern of all Reflector Antenna• Plot Radiation pattern of all Array Antenna• Measure co-polarization, cross polarization 39 Microwave Test Bench (KLYSTRONBased)Klystron Power Supply: Specifications:Input Voltage -230V+/- 10%, 50Hz AC, Beam supply- Voltage:200-450V continuously variable; Current:Regulation: better than 0.5% for +/-10% variation in mains supply voltage; Ripple: less than 5mV rms ,Repeller Supply -Voltage:-10V to -270V continuously variable with respect to klystron cathodeRegulation: better than 0.25% for +/-10% variation in mains supply volt , Heater Supply - 6.3V DC (regulated)Modulation- Square Wave : Frequency 500Hz to 2000Hz; Max. Amplitude- +110V peak to peak, Amplitude and frequency continuously variable; Sawtooth- Frequency 50Hz to 150Hz; Max. Amplitude- 60V peak to peak, Amplitude and frequency continuously variable.VSWR Meter: (Sensitivity: 0.2 micro Volts at a 200 ohm input impedance for full scale deflection, Noise level: At least 5 dB below full scale at rated sensitivity and maximum, bandwidth with input terminated in 100 ohms and 500 ohms for low and high respectively, A/C output : BNC Connector for amplified output, Frequency : 1000Hz +/- 10%,Power : 230 Volts AC, 50Hz, mains supply) 40 ASK / PSK / FSK Modulation And Demodulation KitFEATURES•VLSI based design •Separate component and operational area •Acrylic cover for component safety •Modular organization of circuit functions •Test points to access signals at every stage of circuit operation •Multimedia based interactive e-manual Data Simulator: Onboard 8-bit variable NRZ-L pattern,Crystal Oscillator: 32.768 MHz,Data Clock: 256 KHz,Data Format: NRZ (L),Onboard Carrier Sine Waves : 1MHz (0°), 1MHz (180°), 500 KHz (0°),Power Supply: +12V, -12V, +5V, GND. 41 Microwave Test Bench (GUNN Based)Gunn microwave test bench:Gunn Power Supply (0 - 12 Volts variable,1 Amp. Max,Modulation Frequency: 1KHz +/- 10% (900-1100 Hz),Output Connector: BNC(F) for Gunn Oscillator & TNC(F) for Pin Modulator,Modulation: Square Wave, Frequency : 500Hz to 2000Hz)• Gunn Oscillator • Isolator• PIN modulator• Variable attenuator • Detector Mount• SWR meter(Sensitivity: 0.2 micro Volts at a 200 ohm input impedance for full scale deflection, Noise level: At least 5 dB below full scale at rated sensitivity and maximum, bandwidth with input terminated in 100 ohms and 500 ohms for low and high respectively, A/C output : BNC Connector for amplified output, Frequency : 1000Hz +/- 10%,Powe : 230 Volts AC, 50Hz, mains supply) 42 1 GHz spectrum Analyser1 GHz spectrum Analyser with tracking generatorFrequency range: 150 KHz to 1000 MHzFreqency Resolution: 1 KHz CF entry 40 Hz sweep resolution at 2 KHz per Division,Frequency Display: 61/2 digitFrqency Control: Digital Phase LockResolution Bandwidth: 3 KHz, 30 KHz, 220 KHz, 4 MHz. 43 INDUSTRIAL ELECTRONICS LAB -I (5TH SEM) 44 Trainer Kit to study Reverse Recovery Characteristics of Power DiodesThe single Board trainer Kit should contain IC Regulated Power Supply, Different types power diodes, Digital Ammeter and Voltmeter and other necessary passive components 45 To study drive circuit of SCRIsolated 230 V/40 W AC Power Supply1.2 V to + 15 V/500 mA DC Power Supply* 0-18 V/500 mA,50 Hz, AC Power Supply* Variable frequency triggering pulses* DC Gate signal control, Pulse gate signal * Synchronous AC gate control signal through DIAC* UJT Triggering* 10:1 On- board resistive attenuator * Provision for 40 W Lamp Load* Set of Patch Chords & userManual. 46 To study a single phase rectifier—output waveform with phase control circuitTrainer Kit to study Single Phase Full wave Bridge Rectifier for fixedDC output, Half Controlled and fully controlled rectification facilities with R and RL, loads 1000 Ohms 10 Watts, 14 ma @ 0.05 A inductive loads.The Single Board Trainer Kit contains :(i) Source for rectification of 4 to 24 V DC fixed and variable output @ a max of 500 ma helps to construct and study Series and Parallel resonance Circuit.(ii) Four Diodes and 4 SCRs in bridge configuration with gradual firing controls and necessary capacitive, inductive and Pie filter components.(iii) Digital Ammeter and Voltmeter. 47 To study a polyphase rectifierIsolated 230 V/40 W AC Power Supply Isolated stepped down 3 PH supply. * 3 Phase diode rectifier in open condition*Provision for Load& CRO output.* Electronic phase sequence finder.*Set of Patch Chords & user Manual 48 INDUSTRIAL ELECTRONICS LAB-II (6TH SEM) 49 Servo Regulator Stabilizer Study Kit500VA Servo stabilizer , 2 Amp Variac, Digital input & output meters, Lamp load, Set of Patch Chords & userManual. 50 To study a Jones chopperIsolated 230 V/40 W DC Power Supply, + 5 V/500 mA DC Power Supply* SCR Jones chopper* Gate firing pulses for Jones Chopper* 10:1 On-board Resistive Attenuator* Provision for 40 W Lamp Load* Set of Patch Chords & userManual. 51 To study speed control of induction motor by voltage and frequency variationV/F CONTROLLER 1 HP, AC SQ. CAGE IND. MOTOR 1 HP,DIGITAL VOLT & AMMETER. 1 PHASE I/P & 3 PHASE O/P,3 PH & 1PH MCB PROTECTION 52 To study the speed control of DC motor by:(a) varying field current keeping armature voltage constant; and,(b) varying armature voltage keeping field current constant DC SHUNT MOTOR (FULL COPPER WINDING) .5 HP WITH BASE MOUNT FRAME 1 No VARIAC CONTROLLED 2 DC POWER SUPPLY ( 1 FOR FIELD & 1 FOR ARMATURE)DC VOLT & AMMETER DIGITAL………4 NosPANEL MOUNTED RPM METER………1 No.WHITE BAKELITE FRONT WITH CONN. DIAGRAM & WOODEN SAFETY BOX.METAL FRAME TABLE (Ply board with sun mica) CUM STAND FOR PANEL 53 Power Electronics Devices Trainer KitShould have Built in power supplyDC supply : +/- 12V, 500mA,Power supply 17V / 750mA,Regulated 13.5V/3A O/P mustbe provided as 12V Battery charging supply. Isolated DC supply +12V/ 300mA with isolated common.On board Inverter transformer of Primary : 230V & Secondaries 12-11-0-11-12/3AOn board Lamp load of 15W (100W) should be provided.AC supply : 230V AC line voltage must be made available on two banana 4mm socketsMust have Two pulse transformers of 1:1:1 are provided for isolation & supplying firing pulsesalong with required DC Power supply to experiment panel under test through 15 pin female ‘D’connector.R-L-C Load PanelMust have Load resistor of 10W / 40W --- 1no.Must have Centre tapped 3A choke 4mH/ 16mH each ----2nos.Must have Commutation capacitors of 10mF/100V -------4nos.Must have AC Paper capacitor of 4mF/440V ---1no. 54 PLC Trainer (EXPERIMENT 1-Use of simulation package for different function of PLC. EXPERIMENT 2- Verify function of logic gates by using PLC. EXPERIMENT 3- Write and verify ladder program for motor ON-OFF Control with two push button)HARDWARE SPECIFICATION:TTL Input Switches : 8 Nos,TTL Momentary Switches : 8 Nos., Proximity Switch : 1 No.,Optical Transducer (two state) : 1 No., Programmable LEDs : 8 Nos., Analog input 0 to 5V DC : 8 channels, Analog output 0 to 5V DC : 1 No., 4 to 20mA Transmitter : 1No., 4 to 20mA Receiver : 1No., Current Meter : 25mA FSD 1No.,Voltmeter : 10V FSD 1 No., Piezo Electric Alarm : 1 bit.Built-in power supply.Dedicated I/O interface card suitable for IBM computer suitable for ISA slot. SOFTWARE SPECIFICATION:This is a GUI based LADDER LOGIC SOFTWAREDRAG AND DROP (D&D) an instruction instead of typing an instruction. This eliminates errors in typing. All the instructions are displayed ON-SCREEN during Design time. Each and every element is directly addressed with their NAMES not by numbers or codes, which are very difficult to remember. Ex: At design time, you call a SWITCH#0 in your Ladder program by D&D the component called SWITCH#0, and that’s it, not by typing a few digits numbers or codes.Appropriate LIST boxes (input, output) open as you D&D an instruction in LADDER WORKSPACE.Ladder workspace is 24X100 instruction CELLs are available for your use.TOOL TIP features are available at the end of each instruction prompting you “what to do next”Very user friendly.Extensive ON-LINE HELP menu available.GUI based STATUS of the entire PLC is displayed during RUN TIME.Programs are saved, retrieved, edited by simply clicking on Menu list box.Extensive EDIT features are available. 55 Power Electronics Development TrainerSize of Breadboard : 172.5 mm × 128.5mmDC Power Supply :+5 V, -5 V 500 mA,+12V, -12 V 500 mA+15 V, 250 mA+35V, -35V, 250 mAAC Power Supply :18V-0V-18V ,0V-15VOn board Firing CircuitsFrequency range : 30Hz to 900Hz variableAmplitude : 12VPWM control of G1, G2, G3 and G4Duty cycle control of “Gate”Signal is 0 to 100%SCR Assembly : 4 SCRs 2P4M, 400V/2APower Devices : IGBT-G4BC20S, MOSFETIRFZ44N,UJT-2N2646, DIACDB3,TRIAC-BT136, PUT-2N6027Circuit Components on board : Electrolytic Capacitor 10µF, 63V,Electrolytic Capacitor 1µF, 63V ,Met. Capacitor 0.33µF, 63V ,Diode 1N4007, Inductor 220uH, 4.7µH, 10mH.Pulse transformer on board :2 nos. PT4502 1:1 and one is PT4503 1:1:1Load selector : 6 load resistances- 47E/7W,1K/1W, 1K/10W, 10K/10W,120E/5W, 2K2/2W.Test points : 10 nos (Gold plated)Power Supply (Mains) : 220V/110V, 50Hz/60HzIncluded Accessories :Bread boards : 2 nos.Connecting wires : 20 nos.2mm to 1mm Patch cords : 15 nos.2mm Patch cords (Red) 16” : 4 nos.2mm Patch cords (Black)16’’ : 4 nos.2mm Patch cords (Blue) 16’’ : 12 nos.Mains cord : 1 no.with i) Power Semiconductor Application Experiment Panel ii)CON / INV Panel iii)Triggering circuit / dv/dt Protection panel 56 ELECTRICAL & ELECTRONICS MEASUREMENT LAB (6TH SEM) 57 Digital LCR meterVariable measured- L,C,R and loss angle (D factor ) Measured frequencies: 1 KHz, 100KHzDisplay: 3⅟₂ digit , Resistance: 0 to 20 MΩ, 0.1 Ω , Capacitance: 0 to 20000μF, 0.1 pF Inductance: 0 to 20000 H, 0.1μH ,D factor: 0.01 to 8.0 with 1% error 58 Distortion Factor MeterFrequency : 20 Hz to 200KHz Distortion:0.1% to 100% f.s.d. in steps ,Input sensitivity: 100mV (r.m.s.), Input impedance: 1MΩ/160pF, Voltmeter range: 300μv to 300v f.s.d. in 13 range 59 To measure L & Q by Maxwell methodFULL BRIDGE WITH OSCILLATOR, LED NULL BAR GRAPH & AUDIO AMPR WITH SPEAKER INBUILT FOR NULL IND., DIGITAL MULTIMETER & CRO SIG. O/P INBUILT, IMPORTED (BOURNA) 10 TURN POT FOR NULL ADJ., DECADE INDUCTANCE WITH ROTARY SWITCH INBUILT, BACKLIGHT LED & WOODEN HARD BOX 60 To measure the unknown capacitance by Schering bridgeFULL BRIDGE WITH OSCILLATOR, LED NULL BAR GRAPH & AUDIO AMPR WITH SPEAKER INBUILT FOR NULL IND., DIGITAL MULTIMETER & CRO SIG. O/P INBUILT, IMPORTED (BOURNA) 10 TURN POT FOR NULL ADJ., DECADE INDUCTANCE WITH ROTARY SWITCH INBUILT, BACKLIGHT LED & WOODEN HARD BOX 61 To measure the unknown frequency by Wein BridgeFULL BRIDGE WITH OSCILLATOR, LED NULL BAR GRAPH & AUDIO AMPR WITH SPEAKER INBUILT FOR NULL IND., DIGITAL MULTIMETER WITH FREQ. COUNTER & CRO SIG. O/P INBUILT& CRO SIG. O/P INBUILT, IMPORTED (BOURNA) 10 TURN POT FOR NULL ADJ., BACKLIGHT LED & WOODEN HARD BOX 62 MICROCONTROLLER AND EMBEDDED LAB (5TH SEM) 63 Microcontroller Trainer Kit 1.Write a Simple Assembly Programs fora. Addition b. Subtraction b. Multiplication d. Division2. Write a Programs for (any two of the following)i. 4 x 4 Matrix Keypad Interfaceii. character based LCD Interfaceiii. Analog to Digital Conversion (On chip ADC)iv. Serial EEPROMv. Seven Segment LED Display Interfacevi. Interfacing With Temperature Sensorvii. Stepper Motor Interface8 BIT EMBEDDED MICROCONTROLLER TRAINERFEATURES•Single board design with various resources•Excellent training platform for embedded applications•Software development tools include assembler and ‘C’ compiler•Easy adaptability to different versions of microcontroller in the same family SPECIFICATIONS•Experimental board for 40 pin MCS51 and AVR family of microcontrollers•In-system programming (ISP) facility for many microcontrollers•Double RESET signal with manual key•Crystal frequency: 11.0592MHz•On-board RS232 compatible serial interface terminated in a 9 Pin D female connector•4×4 matrix keyboard•16×2 alphanumeric LCD connector (4-bit interface) and trimmer for contrast adjustment•Four 7-segment LED displays•I2C EEPROM (24Cxx)•Real time clock (DS1307) with lithium battery and SRAM•8-high current output port (500mA) for driving external loads•Two 12V sugar cube relays•Continuous tone piezo buzzer•Temperature sensor socket with thermostat functions•Four 8-bit A/D converter, one 8-bit D/A converter provided by PCF8591•All port-pins available on 10-pin box header•8 LEDs for easy logic state monitoring•8 input trigger switches using 8 push buttons•ISP programming with Flash ISP for AT89S51/52/8252/AVR•Infrared remote control receiver module IC supported•P89V51RD2BN•AT89S52 Installable software on CD•Programmers notepad : Free, open source, text editor•Flash ISP programmer software for 89SXX•Bascom basic compiler (demo version)•MIDE-51: An IDE for MCS-51 microcontroller•WinAVR : open source C compiler for AVR•Sample programs for peripherals DC 12V/500mA output power supplyEXPERIMENTS• Study of LED blink• Study of dancing light• Study of LCD display• Study of LCD-keyboard display• Study of 7 –segment display• Study of RC5 remote control test program• Study of analog to digital converter• Study of real time clock (RTC) 64 ADVANCE COMMUNICATION ENGINEERING LAB 65 To be familiar with the following network components:THIS WILL BE A FULL PACKAGE OF THE FOLLOWINGS:-** RJ5/CAT5CABLES 100 METERSRJ 45CONNECTORS 100 PCSCUTTER & CRIMPING TOOLS FOR RJ45/CAT-5CABLESCABLE TESTER/TRACKER…….. 4 PCSHUBS WITH ACCESSORIES & TOOL KIT NETWORK INTERFACE DIFFERENT CARD 66 COMPUTER NETWORK LAB 67 Network ComponentsCAT 5/5E/6 cable :100mtrs (Rs 2000/-), RJ 45 Connectors: 200pcs (Rs. 500/- )RJ 45 Crimping Tools: 05(Rs. 800/- each)LAN Cable Tester (RJ 45): 05 (Rs 1000/- each) 68 24 Port managed switchNo. of Ports: 10/100 Mbps 24 Ethernet ports, Switch Fabric: 32 Gbps, Form Factor: Rack Mountable,OS: LAN base Image, Console port: Availavble for configuration, Mac Address table: 4000 or higher, VLAN: Supported, MTU: 9100 with support for jumbo frames, Warranty: 3 years onsite comprehensive warranty including parts and labor plus onsite technical support with 24x7 69 24 Port Unmanaged switch24-port 10/100/1000Mbps Ethernet switch Wifi Router: 300 Mbps wireless router with 4 LAN ports and 1 WAN port 70 8 port HubExternal Power Supply, 8 Nos RJ-45 connectors for 10BASE-T/100BASE-TX,Ethernet Ports 8-Port, Capacity 1.6 Gbps, Wireless Speed 10 / 100 Mbps 71 Access points54 Mbps Access point for wifi network: No.of Channel: Dual channel for support upto 108 Mbps ( 2x54Mbps), Backbone connectivity: connect over Fast Ethernet through backbone switches, Security: Security enabled Wifi connectivity with option for Broadcast of SSID,Network:802.11 a/b/g/n network support, PoE: PoE enabled, Form factor: Wall or ceilling mountable with physical lock suppor. Warranty and support: 3 years on site comprehensive warranty including parts and labour plus on site technical support with 24 X 7 72 LAN TrainerEthernet (IEEE 802.3 wireless LAN (802.11),Token bus ( 802.4) Token ring ( 802.5), Data rate : 10/100 Mbps for ethernet, 1, 2, 5.5, 11 Mbps for wirless & LAN as per IEEE 802.11b, connectivity through RJ 45 connector. 73 Installation & commissioning of network(i) Laying ofOFC & CAT 6 Cable (ii) splicing (iii) Installation & network testing 74 INSTRUMENTATION AND CONTROL LAB (6th sem) 75 To measure displacement with LVDT ACTUAL LVDT WITHINSTRUMENTATION AMPLIFIERDC O/P WITH DIGITAL METER, 3and 1/2 digit LED display with polarity indicator, sensitivity of 10mV/mm in the range of 10mm. 76 To measure temperature with thermocoupleTHERMOCOUPLE SENSOR IN STEEL CASEELECTRIC WATER JAG.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR MERCURY THERMOMETER 77 To measure temperature with thermistorTHERMOCOUPLE SENSOR IN STEEL CASEELECTRIC WATER JAG.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR MERCURY THERMOMETER 78 To measure pressure with strain gauge STRAIN GAUGE SENSOR WITH WAIGHT LOADING SYSYTEM SAMPLE WEIGHTS.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR 79 To plot the Characteristics of RTD (PT-100)RTD 3 WAIR SENSOR IN STEEL CASEELECTRIC WATER JAG.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR MERCURY THERMOMETER 80 Temperature controller with on-off controller, Temperature controller with PI controller, Temperature controller with PID controllerTemperature controller with facilities for P, I, D and relay control blocks, Operating temperature: Ambient to 90°C, Separate controls for P, I, D channel gains,Two settings for relay hysteresis, Fast 25W oven fitted with IC temperature sensor, Forced cooling option to ready oven for next experiment, Digital display of set and measured temperature on a 3½ digit built-in DVM, 0-9999 sec, timer on panel for a convenient temperature response experiment, Buffered output for recorder 81 CIRCUIT THEORY LAB 82 Determine the permeability of magnetic material by plotting its B-H curveHysteresis Loop Tracer/ BH Curve apparatus220volt AC, 50Hz supply 83 Series parallel resonance of R-L-C cktKit for Series parallel resonance of R-L-C ckt: The Set-up consist of Power supply (with variable frequency), audio oscillator with digital readout, digital RMS meters and different number of inductors (smoothly variable), capacitors, Rheostat, patch cord & manual. 84 SWITCH GEAR LAB 85 Speed control of Induction motor 1ph by using SCR3Φ, 400V ac, 50HZ.,1HP, 1440 rpm. Speed control using ac back to back configuration of SCRs and to note Speed vs. Load Characteristics at open loop condition. This unit should consist of AC 3Φ Induction Motor (1HP) coupled with a (i) DC Shunt Generator (1HP) for loading and (ii) a DC Tachogenerator to be used for speed feedback control. A DC meter must be provided for displaying the speed of the motor from the Tachogenerator with suitable AC Ammeter and Voltmeter for the measurement (AE Make Panel Type or digital) Sheet Metal enclosure with powder coating paint must be provided. (with foundation & Experiment Table) 86 C.T. & P.T. testing trainer kit C.T. & P.T.testing trainer kit - Variable AC voltage source (0-220V)& variable AC current source (0-25A), CT for 25/5A, PT for 220/110V, Autotransformer for voltage & current adjustment, MCB protection, To determine Ratio error, Phase angle error of CT & PT, with Burden box. , polarity check indicator , range selector switch. 87 Induction type electromagnetic relay* Over Current (IDMTL Electro- Mechanical Type , Model CDG-11 or equivalent) Relay,*PSM, TSM setting* Auxiliary Relay,* Counter /Timer,* D.W. Transformer, * Variac,* Knife Switch,* DC power supply for DC auxiliary relay and the relay,* Portable Ammeter.Necessary panel for the complete set up with wooden (teak wood) table (4x3x2.5) 88 Air Circuit BreakerCut section model 89 Transmission line protection simulation KitOver Current, Earth Fault, Over Voltage, Under Voltage, Directional, Differential, Distance protection 90 POWER PLANT LAB 91 Diesel generator power plantmodel of small diesel generator power plant 92 Hydro power plantmodel of micro Hydro power plant 93 Horizontal axis small wind turbinemodel 94 CSP plantmodel 95 MEASUREMENT LAB 96 Kelvin double bridgeCompletely self contained, stand alone unit with built in power supply, required meters, Standard Resistance, wooden bench, high sensitivity spot light type galvanometer, connecting patch chords and operating manuals. 97 RENEWABLE ENERGY LAB 98 Renewable Energy Labsolar PV plant- Model 99 Renewable Energy Labvertical axis small wind turbine- Model 100 ELECTRIC MACHINE LAB 101 VoltmeterVoltmeter (M.I type) 0-150V/300V/500V 102 VoltmeterVoltmeter (M.I type) 0-20V/50V 103 AmmeterAmmeter (M.I type) 0-5A/10A/20A 104 AmmeterAmmeter (M.I type) 0-1A/2A/5A 105 MultimeterAnalog Multi-meter of ISI marked: DC : 0-200 mV/ 1000 V & 0- 2mA – 10 A,AC : 0 – 200mV/1000V &0-2 mA – 20 A, Resistance : 0 – 200 Megaohm, with shock proof protection & other facilities and operatingmanuals. 106 MultimeterDigital Multi-meter of ISI marked: DC : 0-200 mV – 1000 V & 0-2mA – 10 A,AC : 0 – 1000 V & 0- 2mA– 20 A, Resistance : 0 – 200 Megaohm, with diodetesting, data hold, shock proof protection , auto power off etcfacilities and operating manuals. 107 WattmeterDynamometer Wattmeterof ISI marked : Low Power Factor ( 0.2 ) : Current Rating : 5/10 A , Voltage Rating : 150/300 / 600 V , with anti-parallax mirror , 120 mm scale length , knife edge pointer, mouldedBakelite body, portable. 108 VoltmeterVoltmeter (PMMC type) 0-150V/300V 109 AmmeterAmmeter (PMMC type) 0-2A/5A 110 StarterDC 3-point Starter : 220 V DC , 15 A 111 StarterDC 4-point Starter : 220 V DC , 15 A 112 DC Power SupplyDC Power Supply : Input : 415V, #-Phase AC, 50 Hz;Output : 220V DC , 5 KW of a standard make . 113 RheostatRheostat with sliding Jockey : 100 Ohm , 5 A 114 RheostatRheostat with sliding Jockey : 500 Ohm , 5 A 115 Digital Energy MeterDigital Energy Meter of ISI marked: Three Phase AC , 440 V , Maximum 30 A, 50 Hz with operatingmanual. 116 Digital MeggerDigital Megger for measuring insulation resistance of ISI marked: 250 / 500 V, Maximum 200 Mega ohmwith operating manual 117 VariacSingle Phase Variac of ISI marked : Input:– 230 V AC, Output : 0 – 270 V AC , 1 KVA, 50 Hzof a standard make 118 VariacThree Phase Variac of ISI marked : Input:– 415 V AC, Output : 0 – 500 V AC , 3 KVA, 50 Hzof a standard make 119 Clamp on MeterClamp on Meter of ISI marked : Digital type : For measuring Voltage ( AC/DC ), Current ( AC/DC ) , resistance, Power & Power Factor with operating manuals 120 Phase Sequence IndicatorPhase Sequence Indicator of ISI marked : 50 – 500 V AC, 25 – 60 Hz 121 Frequency MeterFrequency Meter of ISI marked: Digital Type : 240 V, 47 – 99 Hz 122 TransformerSingle-Phase Transformer : 1 KVA , 230 V/115V , 50 Hz( Air Cooled) 123 TransformerThree-Phase Transformer : 3 KVA , 415/230 V , 50 Hz 124 3-Ph Resistive LoadThree phase resistive load : 400 V , 6 KW 125 3-Ph Inductive LoadThree phase inductive load : 400 V , 3 KW 126 3-Ph Capacitive LoadThree phase capacitive load : 400 V , 3 KW 127 3-Ph StarterStar Delta automatic starter for 3 Phase,400 V, 5 Hpmotor 128 3-Ph DOL StarterDOL & Auto -Transformer Starter : 3-phase AC , 400V, 10A, 50 Hz 129 StroboscopeDigital Stroboscope - 10,000 rpm 130 DCGenerator Voltage build UPSupply, Installation , Commissioning & Testing with suitable ISI markedammeter, voltmeter, starter, rheostat , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :For Building up Voltage in DC Generator ( Open Circuit / Saturation Characteristics: DC Shunt Motor of ISI marked : 2HP or 5HP, 220 V. Machines will have to be set on M.S.Channel base with suitable footing/fixtures and screws etc. and operating manual isalso must.(with foundation & Experiment Table) 131 Brake test in DC Series Motor Supply, Installation , Commissioning & Testing with suitable ISI markedammeter, voltmeter, starter, rheostat , digital tachometer , Spring balance & loadings, protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :For Brake test in DC Series Motor& load Characteristics: DC Series Motor of ISI marked : 2HP, 220 V.Machineswill have to be set on M.S.Channel base with suitable footing/ fixtures and screws etc. and operatingmanual is also must.(with foundation & Experiment Table) 132 Speed Controlof 3-Phase Squirrel cage Induction motorSupply, Installation , Commissioning & Testing with necessary & suitable ISI marked meters such as ammeter, voltmeter, frequency meter , starter, protective devices and all other accessories mounted on a standing panel board as per following specification :For Speed Controlof 3-Phase Squirrel cage Induction motorby – (i) volt /freq control method : Three phase Squirrel cage induction motor : 2HP, 400V with v/f controller.Machineswill have to be set on M.S.Channel base with suitablefooting/fixturesandscrewsetc.includingtheoperating manual.(with foundation & Experiment Table) 133 Load Test of an Alternator & % regulation at various loads with Unity Power factorSupply, Installation , Commissioning & Testing with suitable ISI marked ammeter, voltmeter, starter, star connected load , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :For Load Test of an Alternator and Determination of%-age regulation at various loads with unity power factor : DC Shunt Motor of ISI marked : 3HP, 220 V , AlternatorISI marked: 2 KVA, 415 V , 50 Hz.Machineswill have to be set on M.S.Channel base with suitable footing/fixtures and screws etc. and andoperating manual is also must.(with foundation & Experiment Table) 134 Measurement of Slip of 3-Phase induction motorSupply, Installation , Commissioning & Testing with suitable ISI marked meters such as ammeter, voltmeter, frequency meter, stroboscope etc , starter , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :Measurement of Slip of 3-Phase induction motor by –(i) Stroboscopic& (ii ) Tachometer methods and reversing the direction of rotation of the motor : Three phase squirrel cage induction motor of ISI marked: 2 HP , 415 V , 50 Hz .Machineswill have to be set on M.S.Channel base withsuitable footing/fixtures and screws etc. and and operating manual is also must.(with foundation & Experiment Table) 135 Synchronization of two 3-Phase alternatorsSupply, Installation , Commissioning & Testing with suitable ISI marked meters such as ammeter, voltmeter, frequency meter etc , starter , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification : Synchronization of 3-Phase alternator ( 2 SETS ) by– (a) Three Lamp & (b) Synchroscope Methods : DC Shunt Motors of ISI marked : 5HP, 220 V ,Alternators of ISI marked: 3 KVA, 400 V, 50 Hz.Machineswill have to be set on M.S.Channel base withsuitable footings/fixtures and screws etc. and and operating manual is also must.(with foundation & Experiment Table) 136 POWER SYSTEM LAB 137 KIT FOR STUDY OF ACTIVE & REACTIVE POWERWITH SIMULATIOL KIT & LAPTOPStudy of Active & Reactive power with simulator Kit and Laptop with appropriate software, The kit should consist of variable Inductive & Capacitive load to observe change in active & Reactive power 138 MODEL OF VARIOUS TYPES OF TURBINES USED IN POWER GENERATING STATIONSModel Piece of each type of Turbine 139 PYRANOMETERMEASUREMENT OF SOLAR RADIATION BY PYRANOMETER 140 PHOTO VOLATIC SYSTEM USED IN STREET LIGHTWITH SOLAR PLATE,PV CELL,BATTERY,CHARGER 141 STUDY OF POWER SYSTEM OF 6.6 KV/400 V SUBSTATION USED FOR A HOUSING CONPLEXMODEL 142 D.C NETWORK ANALYSERD.C NETWORK ANALYSER FOR STUDY OF DIFFERENT TYPES OF FAULTS 143 DIFFERENT TYPE OF EXCITATIONS SYSTEM USED IN ALTERNATORSTATIC EXCITER,SHAFT MOUNTED,ROTATNG TYPE EXCITER & Brushless exciter ( Model only) 144 MISCELLANEOUS 145 MOTOR-ALTERNATOR SET FOR SYNCHRONISATION OF TWO ALTERNATOR WITH SYCHRONISING PANEL INCLUDING CHECK SYNCHROSCOPE & BULB ARRANGEMENT TO PERFORM TWO BRIGHT ONE DARK LAMP METHOD1.TWO SET OF D.C MOTOR 2.5 KW,230 VOLT,3000 R.P.M WITH SPEED CONTROL ARRANGEMENT 2. TWO SET OF 1 KVA,3 PHASE,440 VOLT,3000 R.P.M ALTERNATOR WITH BASE MOUNTING & EXCITATION SYSTEM. 146 PlierPlier of good quality 147 TesterTester Screwdriver of reputed brand 148 Screwdriver setScrewdriver set of reputed brand
Contract Date: Mar 12, 2026 Contract Value : 33.87 Lakh
Government Departments No of Bidders 9
West Bengal View Result →
36.
Educational and Research Institute #9788745 Technical Bid
Supply Of Printed Books As Per Tender Document , Printed Books : , Fundamentals Of Chemistry, Quantitative Analysis, 1Stedition/R. L. Madan/S. Chand/9355011628/English , Principles Of Physical Chemistry, 49Th Edition/Puri, Sharma, Pathania/Vishal Publication Co./9382956018/English , General And Inorganic Chemistry,Vol 1, 3Rd Edition/R. P. Sarkar/New Central Book Agency/8173816808/English , General And Inorganic Chemistry,Vol 2, 3Rd Edition/R. P. Sarkar/New Central Book Agency/8173817278/English , Modern Inorganic Chemistry/R. N. Madan/S. Chand/8121900743/English , The World Of Physical Chemistry/Keijth J. Laidler/Oup Oxford/978-8123906454/English , States Of Matter And Ions In Solution, 6Th Ed.,Vol1/K. L. Kapoor/Mcgraw Hill Education/9353165180/English , A Textbook Of Physical Chemistry, Thermo-Dynamics And Chemical Equilibrium (Si Units) - Vol. 2 | 6Th Edition/K. L. Kapoor/Mcgraw Hill Education/9353165202/English , A Textbook Of Physical Chemistry - Application Of Thermodynamics | Volume 3, 5Th Edition/K. L. Kapoor/Mcgraw Hill Education/9389811309/English , A Textbook Of Physical Chemistry - Quantum Chemistry And Molecular Spectroscopy | Volume 4, 6Th Edition/K. L. Kapoor/Mcgraw Hill Education/9389811317/English , A Textbook Of Physical Chemistry - Dynamics Of Chemical Reactions, Statistical Thermodynamics, Macromolecules And Irreversible Processes/K. L. Kapoor/Mcgraw Hill Education/9389811325/English , A Textbook Of Physical Chemistry, Computational Aspects In Physical Chemistry (Si Units)Volume 6, 4/E/K. L. Kapoor/Mcgraw Hill Education/9353165210/English , A Textbook Of Physical Chemistry: Experimental Aspects In Physical Chemistry (Si Units) Vol- 7/K. L. Kapoor/Mcgraw Hill Education/9353165482/English , Fundamental Concepts Of Inorganic Chemistry , Volume 1, 3Rd Ed/Asim K Das And Mahua Das/Cbs/9389565979/English , Fundamental Concepts Of Inorganic Chemistry Vol 2, 3Rd Edition/Asim K Das/Cbs/9389688027/English , Fundamental Concepts Of Inorganic Chemistry Vol 3A 3Ed/Asim K Das/Cbs/9390709113/English , Fundamental Concepts Of Inorganic Chemistry Vol 3B 3Ed/Asim K Das/Cbs/9390709121/English , Fundamental Concepts Of Inorganic Chemistry, Volume 4, Including Coordination Chemistry - 2/E/Asim .K Das/Cbs/9354661890/English , Fundamental Concepts Of Inorganic Chemistry: Volume 4/Asim K Das And Mahua Das/Cbs/8123923512/English , Fundamental Concepts Of Inorganic Chemistry Vol 5/Asim K. Das And Mahua Das/Cbs/8123923529/English , Fundamental Concepts Of Inorganic Chemistry, Vol.6/Asim K. Das And Mahua Das/Cbs/8123923536/English , Organic Chemistry Vol. 1/S.M.Mukharji, S.P.Singh, R.P. Kapoor/New Age Publishers/8122427383/English , Organic Chemistry Vol. 2/S.M.Mukharji, S.P.Singh, R.P. Kapoor/New Age Publishers/8122433685/English , Organic Chemistry Vol. 3/S.M.Mukharji, S.P.Singh, R.P. Kapoor/New Age Publishers/8122436110/English , Advanced Organic Chemistry/Jagdamba Singh, L.D.S. Yadav, Jaya Singh/Pragati Publisher/978-9385904363/English , Introduction To Spectroscopy, 5Th Edition/Pavia, Lampman, Kriz, Vyvyan/Cengage India Private Limited/9381466475/English , Advanced Practical Chemistry/Subhas C Das/The World Press Private Limited/8190194402/English , Organic Chemistry, 2E/Jonathan Clayden/Oxford University Press/978-0198728719/English , A Guidebook To Mechanism In Organic Chemistry, 6E/Peter Sykes/Pearson Education/8177584332/English , Organic Chemistry/Subrata Sengupta/Oxford University Press/978-0199451647/English , Advanced Organic Reaction Mechanism/N Tewari/Books & Allied/8187134565/English , Organic Reactions And Their Mechanisms/P.S. Kalsi/New Age International Private Limited/9389802083/English , Spectroscopy Of Organic Compounds/P.S. Kalsi/New Age International Private Limited/8122440638/English , Organic Chemistry, Vol. 1, 6E/I. L. Finar/Pearson Education India/8177585428/English , Organic Chemistry Vol 2/I. L. Finar/Pearson Education India/8177585414/English , Problem And Solutions In Organic Chemistry/I. L. Finar/Pearson Education India/8131700938/English , Principles Of Inorganic Chemistry/Puri Sharma Kalia/Vishal Publishing Co./8192143333/English , Coordination Chemistry - Sixth Edition/Ajai Kumar/Aaryush Education/8193043707/English , Concise Inorganic Chemistry, 5/E/J. D. Lee/Oxford University Press/8126515546/English , Inorganic Chemistry/Catherine Housecroft/Pearson/978-1292134147/English , Organic Chemistry: Aspect And Causal Structure/Jonathan Clayden/Oxford/978-0199270293/English , Practical Organic Chemistry/Frederick George Mann And B Charles Saunders/Pearson Education India/8131727102/English , Advanced Practical Organic Chemistry - 3Rd Edn/N K Vishnoi/S Chand/8125931287/English , Organic Reaction Mechanisms, Selected Problems, And Solutions/William C. Groutas/Crc Press/978-1032488257/English , Advanced Practical Inorganic Chemistry/Gurdeep Raj/Krishna Prakashan Media (P) Ltd/8185842833/English , Fundamental Concepts Of Inorganic Chemistry Vol 7/Asim K. Das And Mahua Das/Cbs/8123923543/English , Introduction To Electro- Dynamics/David J. Griffiths/Pearson Education India Learning Pvt.Ltd/978-9332550445/English , Principles Of Optics/Max Born & Emil Wolf/Cambridge University Press/978-0521639217/English , Optics/Ajoy K Ghatak/Mcgraw Hill/978-9355328595/English , Optics/Eugene Hecht & A.R. Ganesan/Pearson Education/978-9353439590/English , Fundamentals Of Optics (Indian Edition)/Jenkins And White/Mcgraw Hill Inc., Us/978-0070323285/English , Thermo-Dynamics Kinetic Theory And Statistical Thermodynamics/Sears Salinger/Narosa Publishing House/978-8185015712/English , University Physics With Modern Physics, 15E/Hugh D. Young And Roger A. Freedman/Pearsoneducation/978-9353949297/English , Heat And Thermo- Dynamics/Mark W. Zemansky/Mcgraw Hill Inc., Us/978-0070700352/English , Thermal Physics Kinetic Theory Thermodynamics And Statistical Mechanics/S.C. Garg, R.M. Bansal And C.K. Ghosh/Mcgraw Hill/978-1259003356/English , Thermodynamics/Enrico Fermi/Dover Publication Inc./978-0486603612/English , Statistical Mechanics, 4Th Edition/R.K. Pathria And Paul D. Beale/Academic Press/978-0081026922/English , Fundamentals Of Statistical And Thermal Physics/F. Reif/Levant Books/978-9380663142/English , Statistical Mechanics, 2Ed/K. Huang/Wiley/978-8126518494/English , Quantum Mechanics/L.I. Schiff/Mcgraw Hill Education/978-1259062865/English , Quantum Physics, 3Ed/S. Gasiorowicz/Wiley/978-8126511174/English , Quantum Mechanics/B. Craseman/Dover Publications/978-0486794594/English , Quantum Mechanics/Albert Messiah/Dover Publications Inc./978-0486784557/English , Modern Quantum Mechanics/J J Sakurai And Jim Napolitano/Cambridge University Press/978-1108473224/English , A Textbook Of Quantum Mechanics/Mathews And Venkatesan/Mcgraw-Hill Education / India/978-0070965102/English , Introduction To Quantum Mechanics, 3Rd Edition/David J Griffiths/Cambridge University Press/978-1108791106/English , Millmans Integrated Electronics,2Nd Edition/Jacob Millman, Christos Halkias And Chetan D Parikh/Mcgraw Hill Education/978-0070151420/English , Electronic Principles (Sie) | 7Th Edition/Albert Malvino/Mcgraw Hill Education/978-0070634244/English , Electronic Fundamentals And Applications: Integrated And Discrete Systems/John D. Ryder/Prentice Hall India Learning Private Limited/978-8120300828/English , Op-Amps And Linear Integrated Circuits/Ramakant A. Gayakwad/Pearson Publication/978- 8120320581/English , Electronics Fundamentals And Applications/D Chattopadhyay And P C Rakshit/New Age International Private Limited/978-9387788633/English , Electronic Devices And Circuit Theory 11Th Edition/R L Boyelstad/Pearson Education India/978- 9332542600/English , Fundamentals Of Digital Circuits/A Anand Kumar/Phi/978-8120352681/English , Modern Digital Electronics | Fourth Edition/R P Jain/Mcgraw Hill Education/978-0070669116/English , Digital Fundamentals, 11Th Edition/Thomas L Floyd/Pearson Education India/978-9332584600/English , Physics Of Atoms And Molecules, 2Nd Edition/B H Bransden And C J Joachain/Pearson/978-8177582796/English , Introduction To Atomic Spectra/H. E. White/Mcgrawhill Exclusive (Cbs)/978-9352604777/English , Atomic And Molecular Physics/Raj Kumar/Campus Books International/978-8180300356/English , Atomic Physics (Modern Physics)/Dr. Sn Ghoshal/S Chand & Company/978-8121910958/English , Nuclear Physics/Dr. Sn Ghoshal/S Chand & Company/978-9352837274/English , Nuclear Physics: Theory And Experiments/R R Roy And B P Nigam/New Age International Pvt Ltd/978-8122434101/English , Introductory Nuclear Physics/K S Krane/Wiley/978-8126517855/English , Nuclear Physics/D C Tayal/Himalaya Publishing House/978-9350978306/English , Mathematical Physics , 6Th Edition/H. K. Dass & Dr. Rama Verma/S. Chand/8121914698/English , Mathematical Physics ,4Th Edition/B. D. Gupta/Vikas Publishing House/978-9354535062/English , Classical Mechanics/Herbert Goldstein/Pearson/978-8131758915/English , Electromagnetic Theory & Electrodynamics/Satya Prakash/Kedar Nath & Ram Nath/978-8190621696/English , Electromagnetic Field Theory/S.K. Gupta/Krishan Prakashan/978-6200782281/English , Advanced Engineering Mathematics./Jain And Iyengar/Alpha Science International Ltd/8184875606/English , An Introduction To Analysis:Differential Calculus./R. K. Ghosh&K. C. Maity/New Central Book Agency/8173814376/English , Vector Analysis./Maity And Ghosh/New Central Book Agency/817381113X/English , Advanced Higher Algebra/Ghosh And Chakraborty/U. N, Dhur/9380673671/English , Complex Variables:Theory And Applications./H. S. Kasana/Prentice Hall India/8120326415/English , Thomas’S Calculus/Thomas And Finney/Pearson Publishers/134438981/English , Linear Algebra Done Right, 2Nd Edn/Axler/Springer International Student Edition/978-0387982588/English , Linear Algebra, 2Nd Edn/Hoffman, K., Kunze/Prentice Hall Int. Inc., Englewood Cliffs/978-0135367971/English , Ordinary And Partial Differential Equation/M.D. Raisinghania/S. Chand/978-9352837305/English , An Introduction To Ordinary Differential Equations/E. A. Coddington/Prentice Hall India/978-8120305479/English , Partial Differential Equations/L. C. Evans/The Orient Blackswan/978-1470414979/English , Introduction To Real Analysis/S.K. Mapa/Sarat Impressions Pvt. Ltd/978-9382124318/English , Introduction To Complex Analysis/H. A. Priestly/Clarendon Press, Oxford/978-0198525622/English , Computer Programming In C/V. Rajaraman/Prentice Hall, India/978-8120353302/English , Basic Computation And Programming With C/Subrata Saha, Subhodip Mukherjee/Cambridge University Press/978-1109468077/English , Introductory Methods Of Numerical Analysis/S. S. Sastry/Phi/978-8120345925/English , An Introduction To Numerical Analysis (Indian Edition)/Kendall E. Atkinson/Wiley India Private Limited/978-8126518500/English , Linear Programming And Game Theory/J. G. Chakravorty And P. R. Ghosh/Mouli K Library/B08sk4sdpr/English , Mathematical Programming Techniques/Kambo/East-West Publi./978-8185336473/English , Operations Research/S. D. Sharma/Kedarnath/978-8190701105/English , Numerical Methods And Computer Programming/Anju Khandelwal/Narosa/978-8184874157/English , C Language And Numerical Methods/C. Xavier/New Age Int. Publishers/978-8122411741/English , Introduction To Mathematical Statistics/Robert V. Hogg, Joseph W. Mckean/Pearson Education/978-0321795434/English , Statistical Methods—Combined Edition (Vol. I & Ii)/N.G. Das/Mc. Graw Hill Education/978-9352605225/English , Co-Ordinate Geometry (2-D And 3-D)/Ajay Kumar, Ravi Prakash, Usha Gupta/Mcgrawhilleducation/978-9352602019/English , Golden Co-Ordinate Geometry/N.P. Bali/Laxmi Publications/978-8131803803/English , Engineering Mechanics, Statics And Dynamics/Rao/Pearson Education/978-8131718663/English , Elements Of Statics & Dynamics/Loney, S. L/Maxford Books/978-8183410078/English , Cryptography, Theory & Practice/Douglas R. Stinson/Crc Press/978-1138451090/English , Introduction To Algebraic Number Theory/Saban Alaca, Kenneth S Williams/Cambridge University Press/978-0521540117/English , Elementary Number Theory & Its Applications, At&T Bell Laboratories/Kenneth. H. Rosen/Pearson Education Limited /978-9367130681/English , Ancient Indian Education:Brahmanical & Buddhist/R.K Mookerji/Motilal Banarsidass/978-8120804234/English , Indian Education: An Enquiry Into Its Origin, Development And Ideals/F.E Keay/Forgotten Books/978-1334676208/English , History Of Education Policymaking In India(1947-2016)/R.V Vaidyanatha Iyer/Oup India/978-0199474943/English , Education In India After Independence/Jagdish Chand/Shipra Publication/978-8183641067/English , A Cultural History Of India/A.L. Basham/Oxford University Press/978-0195639216/English , The Wonder That Was India/A.L. Basham/Picader/9389109345/English , Evolution Of Indian Culture- From The Earliest Times To The Present Day/B.N Lunia/Lakshmi Narain Agarwal/B08gsbp74z/English , Advanced Educational Psychology/S.K Mangal/Phi Learning/978-8120320383/English , Theories Of Personality/C.S. Hall,L.Gardner, B.C Jhon/Wiley India Pvt. Ltd/978-8126510924/English , Child Growth And Development/E.B Hurlock/Kessinger Publishing/978-1163145791/English , Handbook Of The Teaching Of Psychology/W. Buskist, S.F Davis (Eds)/Blackwell Publication/978-1405138017/English , Cognitive Psychology Mind And Brain/E.E Smith, S.M Kosslyn/Pearson Education India/978-9332550452/English , Developmental Psychology: A Lifespan Approach/E.B Hurlock/Mcgraw -Hill/978-0070993631/English , Educational Psychology/A Woolfolk/Pearson Publication/978-9332586697/English , Becoming Critical Teacher Educatore: Narratives Of Disruption/Julie Ellison Justic,F.Blake Tenore/Routledge/978-1138225145/English , The Oxford Handbook Of Philosophy Of Education/H. Siegal/Oxford University Press/978-0199915729/English , Education In Emerging Indian Society/A.S Thakur, S. Berwal/Mayur Paperbacks/978-8171981786/English , Sociology Basic Concepts/H.K. Rawat/Rawat Publication/978-8131600559/English , Sociology:Principles Of Sociology With An Introduction To Social Thoughts/C.N.S Rao(Eds)/S.Chand & Company Pvt. Ltd/B08ykfnrvm/English , Cyber Law: Maximising Safety And Minimizing Risk In Classrooms/A.M. Bissonette/Sage Publication India Pvt Ltd/978-1412966153/English , Blended Learning In Action: A Practical Guide Toward Sustainable Change/C.R.Tucker, T. Wycoff, J.T. Green/Corwin/978-1506341163/English , Educational Evaluation: Theory And Practice/R.N Patel/Himalaya Publishing House/978-9350244593/English , Essential Of Examination System: Evaluation,Tests And Measurement/J.C Aggarwal/Vikash Publishing House Pvt. Ltd/8125900519/English , Measurement And Assessment In Teaching/M.David Miller,Robert L.Linn And Norman Gronlund/Pearson/978-8131720752/English , The Journey Of Inclusive Education In The Indian Sub-Continent/M.Alur, M.Bach/Routledge/978-0415988766/English , Inclusive Education:International Policy & Practice/A.C Armstrong, D Armstrong& I Spandagou/Sage Publication/978-1847879417/English , Counselling And Guidance/S Rao/Mcgraw -Hill/978-1259005077/English , Guidance & Counselling For Children And Adolescence In Schools (India)/Namita Ranganathan, Toolika Wadhwa/Sage Publication/9386062917/English , Policy, Practice & Politics In Teacher Education/Marilyn Cochran Smith/Corwin Publication/978-1412928113/English , Pedagogy Of English/M.S Sachdeva/Twenty-First Century Publication/978-9385446689/English , Pedagogy Of Education/Dr. Marami Goswami/Neekamal/978-8170637134/English , Philosophical And Sociological Perspectives Of Education/Prof. Raman Bihari Lal And Suneeta Palod/R.Lall/978-9385282805/English , Learning And Teaching/Dr. Sk Mangal And Dr. (Mrs) Uma Mangal/Phi Learning Pvt. Ltd./978-9388028189/English , The Practice Of English Language Teaching 5Th Edition/Jeremy Harmer/Pearson Longman/978-1447980254/English , Approaches And Methods In Language Teaching/Theodore S. Rodgers And Jack C. Richards/Cambridge University Press (South Africa)/978-1107675964/English , Pedagogy Of Language Teaching/Samir Kumar Mahato, Aabriti Sharma/Rita Publications/978-9382229025/English , Pedagogy Of Mathematics/Madhu Sahni/Vikas Publishing/978-9353383275/English , Pedagogy Of Mathematics/Dr. S. K. Mangal/Tondon Publication/B08pbzyxwf/English , General And Inorganic Chemistry (Vol- 1 & 2)/R. P. Sarkar/New Central Book Agency/978-8173816802/English , The Hundred-Year-Old Man Who Climbed Out Of The Window And Disappeared/Jonas Jonasson/Abacus/978-0349141800/English , When Youre Ready, This Is How You Heal/Brianna Wiest/Amaryllis/978-9355435538/English , The Strength In Our Scars/Bianca Sparacino/Amaryllis/978-9355439291/English , A Gentle Reminder/Bianca Sparacino/Amaryllis (An Imprint Of Manjul Publishing House)/978-9355438485/English , The Four Agreements/Don Miguel Ruiz/Amber-Allen Publishing/978-1878424402/English , The Voice Of Knowledge/Don Miguel Ruiz/Amber-Allen Publishing/978-1878424549/English , No Worries/Bella Mente Press/Bella Mente Press/978-1952676000/English , Data Structures And Algorithms Made Easy/Karumanchi Narasimha/Careermonk Publications/978-8193245279/English , Attitude Is Everything Change Your Attitude Change Your Life/Jeff Keller/Collins/978-9351772071/English , Who Moved My Cheese - An Amazing Way To Deal With Change In Your Work And In Your Life./Dr Spencer Johnson/Ebury Publishing/978-0091816971/English , Little Women/Louisa May Alcott/Fingerprint Publishing/978-9354406300/English , The Law Of Success In Sixteen Lessons/Napoleon Hill/Fingerprint! Publishing/978-9388144346/English , The Power Of Prayer/Dr. Joseph Murphy/Fingerprint! Publishing/978-9389053784/English , The Pursuit Of Happiness/Daniel G. Brinton/Fingerprint! Publishing/978-9388369091/English , A Midsummer Night’S Dream/William Shakespeare/Fingerprint! Publishing/978-8175994508/English , The Inferno/Dante Alighieri/Fingerprint! Publishing/978-8175993884/English , The Complete Novels Of Sherlock Holmes/Arthur Conan Doyle/Fingerprint! Publishing/978-8175994317/English , The Happy Prince And Other Tales/Oscar Wilde/Fingerprint! Publishing/978-9389931006/English , Of Mice And Men/John Steinbeck/Grapevine India/978-9357009522/English , The Slight Edge/Jeff Olson/Greenleaf Book Group Llc/978-1626340466/English , Learning To Silence The Mind: Wellness Through Meditation/Osho/Griffin/978-1250006226/English , All The Light We Cannot See/Anthony Doerr/Harper/978-0008172428/English , Flow: Thepsychology Of Optimal Experience/Mihaly Csikszentmihalyi/Harper Perennial Modern Classics/978-0061339202/English , The Mind-Gut Connection/Emeran Mayer/Harper Wave;/978-0062376589/English , Love Yourself Like Your Life Depends On It/Kamal Ravikant/Harpercollins Publishers/978-0008374709/English , What I Wish I Knew When I Was 2: A Crash Course On Making Your Place In The World/Tina Seeling/Harperone/978-0062047410/English , Almond : A Novel/Won-Pyung Sohn/Harperone/978-0063266919/English , You Can Heal Your Life/Louisa May Alcott/Hay House India/978-8190565585/English , Why Zebras Dont Get Ulcers/Robert M. Sapolsky/Holt Paperbacks/978-0805073690/English , The Psychology Of Money/Morgan Housel/Jaico Publishing House/978-9395970334/English , The 5 Am Club/Robin Sharma/Jaico Publishing House/978-9387944893/English , The Practicing Mind/Thomas M. Sterner/Jaico Publishing House/978-9386867100/English , Who Will Cry When You Die?/Robin Sharma/Jaico Publishing House/978-8179922323/English , The Theory Of Everything/Stephen Hawking/Jaico Publishing House/978-8179925911/English , The Leader Who Had No Title/Robin Sharma/Jaico Publishing House/978-8184951196/English , Chanakya Neeti/Radhakrishnan Pillai/Jaico Publishing House/978-9388423571/English , Brief Answers To The Big Questions:/Stephen Hawking/John Murray/978-8466424578/English , The Miracle Morningthe 6 Habits That Will Transform Your Life Before 8Am/Hal Erold/John Murray One/978-1399816052/English , Dont Believe Everything You Think/Joseph Nguyen/Manjul Publishing House/978-9355431356/English , The Compound Effect/Darren Hardy/Manjul Publishing House/978-9390924639/English , The Art Of Dealing With People/Les Giblin/Manjul Publishing House/978-8183226745/English , The Compound Effect/Darren Hardy/Manjul Publishing House/978-9390924639/English , The Untethered Soul: The Journey Beyond Yourself/Michael A. Singer/New Harbinger/978-1572245372/English , Philip K. Dicks Electric Dreams/Philip K. Dick/Orion Publishing Co/978-1473223288/English , The Hitchhiker’S Guide To The Galaxy/Douglas Adams/Pan/978-1529034523/English , Focus On What Matters/Darius Foroux/Penguin/978-0143461845/English , Why We Sleep/Matthew Walker/Penguin/978-0141983769/English , Energize Your Mind/Gaur Gopal Das/Penguin Ananda/978-0143442288/English , Make Your Bed/Admiral William H. Mcraven/Penguin Books Ltd/978-0718188863/English , Life 3.0: Being Human In The Age Of Artificial Intelligence/Max Tagmark/Penguin Books Ltd/978-0141981802/English , Thinking, Fast And Slow/Kahneman Daniel/Penguin Books Ltd/978-0141033570/English , Start With Why/Sinek Simon/Penguin Books Ltd/978-0241958223/English , Digital Minimalism: Choosing A Focused Life In A Noisy World/Cal Newport/Penguin Business/978-0241737996/English , You Only Live Once/Stuti Changle/Penguin Ebury Press/978-0143453581/English , Do It Today/Darius Forous/Penguin India/978-0265394281/English , Sapiens: A Brief History Of Humankind:/Yuval Noah Harari/Penguin Random House/978-0099590088/English , Three Thousand Stitches/Murty Sudha/Penguin Random House India/978-0143440055/English , Here, There And Everywhere/Murty Sudha/Penguin Random House India/978-0143444343/English , Quiet : The Power Of Introverts In A Wor: The Power Of Introverts In A World That Cant Stop Talking/Susan Cain/Penguin Uk/978-0141029191/English , Blink (L): The Power Of Thinking Without Thinking/Malcolm Gladwell/Penguin Uk/978-0141014593/English , Charisma Myth/Olivia Fox Cabane/Penguin Uk/978-0670922871/English , The Drama Of The Gifted Child/Alice Miller/Perseus Books Group/978-0465016907/English , Before The Coffee Gets Cold*/Toshikazu Kawaguchi/Picador/978-1035035052/English , You Are Born To Blossom/Dr Apj Abdul Kalam/Prabhat Prakashan/978-8184303360/English , The Obstacle Is The Way/Ryan Holiday/Profile Books/978-1781251485/English , Mastery/Robert Greene/Profile Books/978-1781250914/English , The 48 Laws Of Power/Robert Greene/Profile Books/978-1861972781/English , Ego Is The Enemy/Ryan Holiday/Profile Books Ltd/978-1781257012/English , Never Split The Difference/Chris Voss/Random House Business/978-1847941497/English , When Breath Becomes Air/Kalanithi Paul/Random House Usa Inc/978-0812988406/English , Quiet/Cain Susan/Random House Usa Inc/978-0307352156/English , The Wim Hof Method/Wim Hof/Rider/978-1846046308/English , The Art Of Communicating/Thich Nhat Hanh/Rider & Co/978-1846044007/English , Mans Search For Meaning: The Classic Tribute To Hope From The Holocaus/Viktor E. Frankl/Rider & Co/978-1846041242/English , Drive The Surprising Truth About What Motivates Us/Daniel H.Pink/Riverhead Books/978-1594484803/English , Learning How To Fly: Life Lessons For The Youth/A.P.J. Abdul Kalam/Rupa Publications India/978-8129142153/English , The War Of Art: Break Through The Blocks And Win Your Inner Creative Battles/Steven Pressfield/Sanage Publishing House/978-1936891023/English , The Art Of Thinking Clearly/Rolf Dobelli/Sceptre/978-1444759549/English , The Secret/Rhonda Byrne/Simon And Schuster/978-1471172397/English , Memory: How To Develop, Train And Use It/William Walker Atkinson/Srishti Publishers & Distributors/978-9390441020/English , You Can/George Matthew Adams/Srishti Publishers & Distributors/978-9395192460/English , Be Your Own Sunshine: Towards A Better Tomorrow/James Allen/Srishti Publishers & Distributors/978-9387022850/English , When The Body Says No/Dr Gabor Maté/Vermilion/978-1785042225/English , Surrounded By Idiots/Thomas Erikson/Vermilion/978-1785042188/English , Four Thousand Weeks/Oliver Burkeman/Vintage/978-1784704001/English , Homo Deus/Yuval Noah Harari/Vintage/978-1784703936/English , Essentialism: The Disciplined Pursuit Of Less/Greg Mckeown/Virgin Books/978-0753558690/English , What Every Body Is Saying/Marvin Karlins Joe Navarro/William Morrow Paperbacks/978-0063069275/English , Educated/Tara Westover/Windmill Books/978-0099511021/English , Read People Like A Book/Patrick King/Wisdom Tree/978-8183286107/English , Show Your Work!/Austin Kleon/Workman Publishing/978-0761178972/English , Keep Going/Austin Kleon/Workman Publishing/978-1523506644/English , Mans Searching For Meaning/Vickor E.Frankl/Wow Publishing Pvt/978-8184157383/English , The Power Of Now: A Guide To Spiritual Enlightenment/Eckhart Tolle/Yogi Impressions Books Pvt Ltd/978-1444700848/English , Oxford Student Atlas For India/Oxford University Press/Oxford University Press/978-0199470648/English , Oxford Student Atlas/Patrick Wiegand/Oxford University Press/978-0199136988/English , Atomic Habits: An Easy & Proven Way To Build Good Habits & Break Bad Ones/James Clear/Penguin Random House/978-1847941831/English , Ghost Of Fear Streets/R.L. Stine/Aladdin/978-1442486164/English , Andha Yug/Dharamvir Bharati/Oxford University Press/978-0198065227/English , Electric Machines/Ashfaq Hussain/Dhanpat Rai & Co/978-8177001662/English , At The Speed Of Light/G Venkatraman/Universities Press (India)/978-8173710094/English , Quantum Revolution I — The Breakthrough/G Venkatraman/Universities Press (India)/978-8173710025/English , Quantum Revolution Ii — Qed: The Jewel Of Physics/G Venkatraman/Universities Press (India)/978-8173710032/English , Quantum Revolution Iii — What Is Reality?/G Venkatraman/Universities Press (India)/978-8173710049/English , Raman And His Effect/G Venkatraman/Universities Press (India)/978-8173710087/English , Saha And His Formula/G Venkatraman/Universities Press (India)/978-8173710179/English , A Hot Story/G Venkatraman/Universities Press (India)/978-8173710100/English , Why Are Things The Way They Are?/G Venkatraman/Universities Press (India)/978-8173710339/English , The Many Phases Of Matter/G Venkatraman/Universities Press (India)/978-8173710346/English , Bose And His Statistics/G Venkatraman/Universities Press (India)/978-8173710360/English , Chandrasekhar And His Limit/G Venkatraman/Universities Press (India)/978-8173710353/English , Big And The Small, The: Journey Into The Microcosm/G Venkatraman/Universities Press (India)/978-8173712272/English , Big And The Small, The - Vol. Ii : From The Microcosm To The Macrocosm: The Fascinating Link Between Particle Physics And Cosmology/G Venkatraman/Universities Press (India)/978-8173715747/English , Upkar Prakashan Csir - Ugc Net/Jrf/Set Physical Sciences/Surekha Tomar/Upkar Prakashan/B0ckzctk11/English , Death Note Black Edition Vol. 1/Tsugumi Ohba, Takeshi Obata/Viz Media Llc/978-1421539645/English , Attack On Titan Vol. 1/Hajime Isayama/Kodansha Comics/978-1612620244/English , One Piece Omnibus Edition Vol. 1/Eiichiro Oda/Viz Media Llc/978-1421536255/English , Demon Slayer: Kimetsu No Yaiba Vol. 1/Koyoharu Gotouge/Viz Media Llc/978-1974700523/English , Naruto 3-In-1 Edition Vol. 1/Masashi Kishimoto/Viz Media Llc/978-1421539898/English , Your Name. (Light Novel)/Makoto Shinkai/Yen On/978-0316476479/English , Spy X Family Vol. 1/Tatsuya Endo/Viz Media Llc/978-1974715466/English , Chainsaw Man Vol. 1/Tatsuki Fujimoto/Viz Media Llc/978-1974709939/English , 12 Rules For Life: An Antidote To Chaos/Jordan B. Peterson/Penguin Random House/978-0345816023/English , Beyond Order: 12 More Rules For Life/Jordan B. Peterson/Penguin Random House/978-0593084649/English , The Power Of Now/Eckhart Tolle/New World Library/978-1577314806/English , Think Like A Monk/Jay Shetty/Simon & Schuster/978-1982134488/English , Sapiens: A Brief History Of Humankind/Yuval Noah Harari/Harper/978-0062316097/English , Homo Deus: A Brief History Of Tomorrow/Yuval Noah Harari/Harper/978-0062464316/English , 21 Lessons For The 21St Century/Yuval Noah Harari/Spiegel & Grau/978-0525512172/English , Ikigai: The Japanese Secret To A Long And Happy Life/Héctor García, Francesc Miralles/Penguin Random House/978-0143130727/English , The Courage To Be Disliked/Ichiro Kishimi, Fumitake Koga/Allen & Unwin/978-1760630737/English , Flow: The Psychology Of Optimal Experience/Mihaly Csikszentmihalyi/Harper Perennial/978-0061339202/English , The Untethered Soul/Michael A. Singer/New Harbinger Publications/978-1572245372/English , The Subtle Art Of Not Giving A F*Ck/Mark Manson/Harper/978-0062457714/English , Everything Is F*Cked: A Book About Hope/Mark Manson/Harper/978-0062888433/English , Meditations/Marcus Aurelius/Penguin Classics/978-0140449334/English , Bhagavad Gita: As It Is/A.C. Bhaktivedanta Swami Prabhupada/The Bhaktivedanta Book Trust/978-9384564191/English , The Tao Of Physics/Fritjof Capra/Shambhala/978-1570625190/English , The Art Of War/Sun Tzu/Shambhala/978-1590302255/English , A Brief History Of Time/Stephen Hawking/Bantam/978-0553380163/English , Cosmos/Carl Sagan/Ballantine Books/978-0345539434/English , The Brain That Changes Itself/Norman Doidge/Viking/978-0143113102/English , Incognito: The Secret Lives Of The Brain/David Eagleman/Vintage/978-0307389920/English , Thinking, Fast And Slow/Daniel Kahneman/Farrar, Straus And Giroux/978-0374533557/English , Predictably Irrational/Dan Ariely/Harper/978-0061353239/English , The 4-Hour Workweek/Timothy Ferriss/Crown Publishing/978-0307465358/English , Rich Dad Poor Dad/Robert T. Kiyosaki/Plata Publishing/978-1612681139/English , Influence: The Psychology Of Persuasion/Robert Cialdini/Harper Business/978-0061241895/English , Quiet: The Power Of Introverts/Susan Cain/Crown Publishing/978-0307352153/English , Leaders Eat Last/Simon Sinek/Portfolio/978-1591845324/English , Factfulness/Hans Rosling/Flatiron Books/978-1250107817/English , The Alchemist/Paulo Coelho/Harperone/978-0061122415/English , Tuesdays With Morrie/Mitch Albom/Broadway Books/978-0767905923/English , The Kite Runner/Khaled Hosseini/Riverhead Books/978-1594631931/English , A Thousand Splendid Suns/Khaled Hosseini/Riverhead Books/978-1594483851/English , Steve Jobs/Walter Isaacson/Simon & Schuster/978-1451648539/English , Elon Musk/Ashlee Vance/Harper/978-0062301239/English , Shoe Dog/Phil Knight/Scribner/978-1501135910/English , Atomic Habits (Illustrated Edition)/James Clear/Penguin Random House/978-1847948250/English , Vinland Saga Vol. 1/Makoto Yukimura/Kodansha Comics/978-1612624204/English , Fullmetal Alchemist: Fullmetal Edition Vol. 1/Hiromu Arakawa/Viz Media Llc/978-1421599779/English , Monster Vol. 1/Naoki Urasawa/Viz Signature/978-1421569062/English , Vagabond Vol. 1/Takehiko Inoue/Viz Signature/978-1421520544/English , Mushoku Tensei: Jobless Reincarnation (Light Novel) Vol. 1/Rifujin Na Magonote/Seven Seas Entertainment/978-1642751383/English , Re:Zero - Starting Life In Another World Vol. 1/Tappei Nagatsuki/Yen On/978-0316310308/English , No Longer Human/Osamu Dazai/New Directions/978-0811204811/English , Norwegian Wood/Haruki Murakami/Vintage/978-0375704024/English , Harry Potter And The Sorcerer’S Stone/J.K. Rowling/Bloomsbury/978-0747532699/English , Harry Potter And The Chamber Of Secrets/J.K. Rowling/Bloomsbury/978-0747538493/English , Harry Potter And The Prisoner Of Azkaban/J.K. Rowling/Bloomsbury/978-0747542155/English , Harry Potter And The Goblet Of Fire/J.K. Rowling/Bloomsbury/978-0747546245/English , Harry Potter And The Order Of The Phoenix/J.K. Rowling/Bloomsbury/978-0747551003/English , Harry Potter And The Half-Blood Prince/J.K. Rowling/Bloomsbury/978-0747581086/English , Harry Potter And The Deathly Hallows/J.K. Rowling/Bloomsbury/978-0747591054/English , One Piece Vol. 100/Eiichiro Oda/Viz Media Llc/978-1974736263/English , Naruto Vol. 72 (Final Volume)/Masashi Kishimoto/Viz Media Llc/978-1421582849/English , Bleach Vol. 1/Tite Kubo/Viz Media Llc/978-1591164418/English , Bleach Vol. 74 (Final Volume)/Tite Kubo/Viz Media Llc/978-1421598260/English , Dragon Ball Z Vol. 1/Akira Toriyama/Viz Media Llc/978-1569319307/English , Dragon Ball Z Vol. 26 (Final Volume)/Akira Toriyama/Viz Media Llc/978-1569319895/English , My Hero Academia Vol. 1/Kohei Horikoshi/Viz Media Llc/978-1421582696/English , Black Clover Vol. 1/Yuki Tabata/Viz Media Llc/978-1421587189/English , Tokyo Revengers Vol. 1/Ken Wakui/Kodansha Comics/978-1646512195/English , Jojos Bizarre Adventure: Part 1 Phantom Blood Vol. 1/Hirohiko Araki/Viz Media Llc/978-1421578798/English , Neon Genesis Evangelion Vol. 1/Yoshiyuki Sadamoto/Viz Media Llc/978-1569319000/English , The Lord Of The Rings Trilogy (Single Volume Edition)/J.R.R. Tolkien/Harpercollins/978-0261102385/English , Bharat Ka Itihas/Ram Saradh Sharma/Oxford India Paperbacks/9118866109/English , Fabric Of Reality/David Deutsch/Penguin Books/978-0140275414/English , Behave/Robert Sapolsky/Penguin Pr/978-1594205071/English , Number Theory/Hari Kishan/Krishna Prakashan Media P. Ltd./978-8182835696/English , Tripura Through The Ages/Naliniranjan Roychowdhury/Jnan Bichitra/B0cp7n7gzh/English , A Handbook On Comprehension And Communication Skills/Yumnam Oken Singh & Gyanabati Khuraijam/Edsol Informatics/978-8198040268/English , Reading Autobiography: A Guide For Interpreting Life Narratives/Sidonie Smith & Julia Watson/University Ofminnesota Press/978-0816669868/English , A Brief History Of Modern India/Rajiv Ahir/Spectrum Books/978-817930812/English , Indian Art And Culture/Nitin Singhania/Mcgraw Hill/978-9355325983/English , Certificate Physical And Human Geography/Goh Cheng Leong/Oxford University Press/978-0195621253/English , Indian Economy/Ramesh Singh/Mcgraw Hill/978-9357066758/English , Environment/Shankar Ias Academy/Shankar Ias Academy/978-8195484897/English , Lexicon For Ethics, Integrity & Aptitude/Chronicle/Chronicle Publications/978-9390977218/English , Indias Ancient Past/R. S. Sharma/Oxford University Press/978-0199479813/English , History Of Medieval India/Satish Chandra/Orient Blackswan/978-9354422237/English , Challenges To Internal Security Of India/Ashok Kumar & Vipul/Mcgraw Hill/978-9355328816/English , Indian Polity For Civil Services/M. Laxmikanth/Mcgraw Hill/978-9357065997/English , The Undiscovered Self/Carl Jung/Mass Market Paperback/978-0451217325/English , Memories, Dreams, Reflections/Carl Jung/Paperback/978-0679723950/English , Modern Man In Search Of A Soul/Carl Jung/Paperback/978-1684220908/English , How To Meet Your Self/Dr. Nicole Lepera/Paperback/978-1398710733/English , Notes To Myself/Hugh Prather/Paperback/978-0553273823/English , Memory, A Very Short Introduction/Jonathan K. Foster/Oxford/978-0192806758/English , The Routledge History Of Literature In English/Ronald Carter And John Mcrae/Routledge/978-1032097572/English , An Introduction To Cultural Studies/Pramod K. Nayar/Viva Books/978-8130933986/English , Mathematical Methods In The Physical Sciences/Mary L. Boas/John Wiley & Sons/978-0471821735/English , Advanced Engineering Mathematics/Erwin Kreyszig/Wiley/978-0470458365/English , Mathematical Physics/H. K. Dass/S. Chand/978-8121908907/English , An Introduction To Mechanics/Daniel Kleppner & Robert Kolenkow/Cambridge University Press/978-1108645537/English , Waves And Oscillation/N.K. Bajaj/Krishna Prakashan Media/978-8178190873/English , Introduction To Electrodynamics/David J. Griffiths/Pearson/978-9332530012/English , Fundamentals Of Statistical Mechanics & Thermal Physics/F. Reif/Mcgraw-Hill/978-0070698144/English , Thermal Physics: Heat & Thermodynamics/H.P. Roy & A.B. Gupta/New Age Publishers/978-8122438404/English , Introduction To Quantum Mechanics/David J. Griffiths/Pearson/978-1107179868/English , Quantum Physics/H.C. Verma/Surya Publication/978-8175150324/English , Solid State Physics/Puri & Babbar/S. Chand/978-8121907610/English , Electronic Devices And Circuit Theory/Robert L. Boylestad & Louis Nashelsky/Pearson/978-9332572006/English , Concepts Of Physics (Part 1 & 2)/H.C. Verma/Bharati Bhawan Publishers/978-8175150287/English , An Introduction To Modern Astrophysics/Bradley W. Carroll & Dale A. Ostlie/Cambridge University Press/978-1292022932/English , Astrophysics In A Nutshell/Dan Maoz/Princeton University Press/978-0691164793/English , Mindset: The New Psychology Of Success/Carol S. Dweck/Random House/978-0345472328/English , Ssc General Studies 7300+ Questions/Kiran Prakasan/Kiran Prakasan/978-9384761543/English , Quantitative Aptitude For Competitive Examinations/R.S. Aggarwal/S. Chand Publishing/978-9352836536/English , A Mirror Of Common Errors/Dr. Ashok Kumar Singh/Student Friends Publications/978-9380222949/English , Fundamental Concepts Of Inorganic Chemistry, Volume 5/Ashim K Das And Mahua Das/Cbs Publishers And Distributors Pvt Ltd/978-8123923529/English , Fundamental Concepts Of Inorganic Chemistry, Volume 6/Ashim K Das And Mahua Das/Cbs Publishers And Distributors Pvt Ltd/978-8123923536/English , Fundamental Concepts Of Inorganic Chemistry, Volume 7/Ashim K Das And Mahua Das/Cbs Publishers And Distributors Pvt Ltd/978-8123923543/English , Gora/Rabindranath Tagore/Rupa/978-8171677559/English , An Introduction To Supramolecular Chemistry/Ashim K Das And Mahua Das/Cbs Publishers And Distributors Pvt Ltd/978-9390158638/English , An Introduction To Nanomaterials And Nanoscience/Ashim K Das And Mahua Das/Cbs Publishers And Distributors Pvt Ltd/978-9388108010/English , Quantum Chemistry/Donald A Mcqurrie/Viva Books/978-8130918945/English , Electrical Machinery Fundamental/Stephen Chapman/Mcgraw Hill Education/978-0071070522/English , Bose : The Untold Story Of An Inconvenient Nationalist/Chandrachur Ghose/India Penguin/978-0071284448/English , India, That Is Bharat Coloniality, Civilisation, Constitution/J Sai Deepak/Bloomsbury India/978-9354350047/English , India, Bharat And Pakistan The Constitutional Journey Of A Sandwiched Civilisation/J Sai Deepak/Bloomsbury India/978-9354354526/English , 1947-1957, India: The Birth Of A Republic/Chandrachur Ghose/India Penguin/978-0670097104/English , The Bose Deception Declassified/Anuj Dhar, Chandrachur Ghose/India Penguin/978-0670097272/English , Bravehearts Of Bharat Vignettes From Indian History/Vikram Sampath/India Penguin/978-0143468004/English , The Common Man At Large Birth Centenary Edition/R K Laxman/India Penguin/978-0143455776/English , Godel, Escher, Bach/Douglas R. Hofstadter/Basic Books; Anniversary Edition (5 February 1999)/978-0465026562/English , The Road To Reality — Penrose/Roger Penrose/Penguin Random House India Pvt Ltd/978-0099440680/English , The Complete Adventures Of Feluda: Volume One: V. 1 /Satyajit Ray/Penguin India/978-0141000145/English , The Complete Adventures Of Feluda, Volume 2/Satyajit Ray/Penguin India/978-0143032786/English , Best Of Agatha Christie(Set Of 4 Books)/Agatha Christie/Mg Books/978-9388600835/English , Linda Goodmans Sun Signs/Linda Goodman/Bantam/978-0330233903/English , Vastu: The Ultimate Guide To Vastu Shastra And Feng Shui Remedies For Harmonious Living/Mari Silva/Independently Published/979-8576957064/English , Distribution System Modeling And Analysis With Matlab® And Windmil® (Paperback, India)/William H. Kersting/Crc Press (Indian Edition Print)/978-1032938608/English , Engineering Mechanics/Russell C. Hibbeler/Pearson/978-9332584747/English , Ikigai [The Japanese Secret]/Francesc García /Hutchinson/978-1786330895/English , Hadoop: The Definitive Guide, 4Th Edition/Tom White/Shroff / O’Reilly Media/978-9352130672/English , That Is Ros(Robot Operating System)/Suman Deb/Ebh Book House/978-9348106605/English , Heart Lamp/Dr. Banu Mushtaq/India Penguin/978-0143464471/English , Semiconductor Physics And Devices, Indian Adaptation/S.M. Sze & M.K. Lee/Willey/978-9354243226/English , The Art Of Happiness/Dalai Lama/Hodder Paperbacks/978-0802131843/English , The Book Of Joy/Dalai Lama, Desmond Tutu/Penguin Random House Ireland Limited/978-1786330444/English , Pax Indica/Shashi Tharoor/Penguin India/978-0143420187/English , Introduction To Machine Learning With Python : A Guide For Data Scientists/Andreas/Shroff/Oreilly/978-9352134571/English , Programming Computer Vision With Python: Tools And Algorithms For Analyzing Images/Solem/Shroff/Oreilly/978-9350237663/English , Web Content Management: Systems, Features, And Best Practices/Barker/Shroff/Oreilly/978-1491908129/English , Data Management At Scale: Modern Data Architecture With Data Mesh And Data Fabric/Strengholt/Shroff/Oreilly/978-9355429896/English , Database Management Systems/Dr. Suganthi/Shroff/X-Team/978-9352136483/English , Practical Machine Learning For Computer Vision: End-To-End Machine Learning For Images/Lakshmanan/Shroff/Oreilly/978-9391043834/English , Indias Struggle For Independence/Bipan Chandra/Penguin Random House/978-0140107814/English , Geography Of India/Majid Husain / D. R. Khullar/Arihant/978-9326194716/English , General Engineering Study Guide For Rrb, Nhpc, Iol, Dmrc, Ongc, Sail, Gail, Upcl And Other Public Sector Examinations/G K Publications/G K Publications/978-9392837654/English , Tata Mcgraw Hill Csat Manual/Tata Mcgraw Hill/Tata Mcgraw Hill/978-9371532600/English , Nta Csir Ugc Net/Set (Jrf & Lectureship) Physical Science/Arihant Expert/Arihant Expert/978-9311009445/English , Csir-Ugc Net/Jrf/Set Physical Sciences/Physics Wallah Private Limited/Upkar Prakashan/978--8174825278/English , Csir - Net Recap Physical Sciences Chapterwise & Yearwise Previous Years Solved Papers (2025-2015)/Physics Wallah Private Limited/Physics Wallah Private Limited/978-9371538640/English , Iit Jam Recap 20 Years Physics Pyq Chapterwise & Yearwise Previous Year Solved Papers (2005-2024) With 5 Mock Tests/Physics Wallah Private Limited/Physics Wallah Private Limited/978-9348057501/English , Nta 68 Ugc Net Paper 1 (Teaching & Research Aptitude)/Physics Wallah Private Limited/Physics Wallah Private Limited/978-9371532600/English , Think And Grow Rich/Napoleon Hill/Tarcherperigee/978-1585424337/English , The Power Of Habit/Charles Duhigg/Random House Trade/978-0812981605/English , The 7 Habits Of Highly Effective People/Stephen R. Covey/Simon & Schuster/978-2133487538/English , How To Win Friends & Influence People/Dale Carnegie/Simon & Schuster/978-0671027032/English , The Gifts Of Imperfection/Brene Brown/Penguin Random House/978-1785043543/English , Big Magic/Elizabeth Gilbert/Fischer Taschenbuch/978-3104035222/English , Getting Things Done: The Art Of Stress-Free Productivity/David Allen/Piatkus/B00shl3v8m/English , Outliers: The Story Of Success/Malcolm Gladwell/Penguin/B002ri9pko/English , Awaken The Giant Within/Tony Robbins/Dlp Publications/?B00azqq1uw/English , Six Not -So-Easy Pieces/Richard P. Feynman/Helix Books/978-0465025268/English , The Feynmann Lectures On Physics/Richard P. Feynman, Robert B. Leighton/Basic Books/978-0465023820/English , Before Religion/Nitesh Gor/Harper Collins/978-9369896486/English , Balance Sheet/Debarati Mukhopadhyay/Deep Prakashan/B0crntn7xr/English , The Road Less Travelled/M. Scott Peck/Rider & Co./978-0712661157/English , The Argumentative Indian/Amartya Sen/Penguin Uk/978-0141012117/English , Materials Characterization Technique/Ashok Kumar, Lin Li, Sam Zhang/Crc Press Inc/978-1420042948/English , Materials Characterization: Introduction To Microscopic And Spectroscopic Methods/Yang Leng/Wiley-Vch/978-0470822982/English , The Selfish Gene/Richard Dawkins/Oxford University Press/978-0198788607/English , Poor Economics/Abhijit V. Banerjee, Esther Duflo/Random House India/978-8184001815/English , Never Let Me Go/Kazuo Ishiguro/Feber & Faber/978-0571258093/English , Lublur Prithibi/Charbak Dipta/Book Farm/978-9348544902/English , Hacking And Security/Michael Kofler, Klaus Gebeshuber/Shroff / O’Reilly Media/978-1493224258/English , Practical Data Privacy - Enhancing Privacy And Security In Data/Katharine Jarmul/Shroff / O’Reilly Media/978-9355429742/English , Machine Learning And Security - Protecting Systems With Data And Algorithms/Clarence Chio, David Freeman/Shroff / O’Reilly Media/978-9352136933/English , Strengthening Deep Neural Networks - Making Ai Less Susceptible To Adversarial Trickery/Katy War/Shroff / O’Reilly Media/978-9352138739/English , 97 Things Every Information Security Professional Should Know/Christina Morillo/Shroff / O’Reilly Media/978-9355420367/English , Learning Kali Linux- Security Testing, Penetration Testing & Ethical Hacking/Ric Messier/Shroff / O’Reilly Media/978-9352137527/English , Basic Electrical Engineering/A. E. Fitzgerald/Mcgraw Hill Education/978-0070682566/English , Electrical Engineering Fundamentals/Vincent Del Toro/Pearson Education India/978-9332551763/English , Mother Mary Comes To Me/Arundhati Roy/Penguine Hamish Hamilton/978-0143473060/English , 100 Great Iitians Book: Dedicated To The Service Of The Nation/Editor Commander V.K. Jaitly/Excel India Publishers/B0dg61mlwq/English , Empowering India Ideas For Action By Scientist And Engineers/Thalappil Pradeep And Krishnan Narayanan/Indian Academy Of Sciences/8195066410/English , What Is Wrong With You?: A Novel/Paul Rudnick/Blackstone Publishing, Inc./978-1668068298/English , The Housemaid/Freida Mcfadden/India Penguin/B0frm2tyk3/English , A Burning/Megha Majumdar/Penguin Hamish Hamilton/978-0670093793/English , The Silent Patient/Alex Michaelides/Celadon Books/978-1409181637/English , 400 Days/Chetan Bhagat/Westland Publication/978-1542094085/English , 12 Years: My Messed-Up Love Story/Rithvik Singh/Fingerprint! Publishing/978-9369896875/English , The Room On The Roof/Ruskin Bond/Puffin/978-0143333388/English , Five Point Someone/Chetan Bhagat/Rupa Publications India/978-8129104595/English , The Power Of Your Subconscious Mind/Jopesh Murphy/Srishti Publishers & Distributors/978-8172345662/English , Dont Believe Everything You Think (English)/Joseph Nguyen/Manjul Publishing House/978-9355431356/English , The Mountain Is You: Transforming Self-Sabotage Into Self-Mastery (English)/Brianna Wiest/Amaryllis (An Imprint Of Manjul Publishing House)/978-1949759228/English , How To Win Friends And Influence People/Dale Carnegie/Srishti Publishers & Distributors/978-0671027032/English , The Psychology Of Money/Morgan Housel/Jaico Publishing House/978-9395970334/English , Dopamine Detox: A Short Guide To Remove Distractions And Get Your Brain To Do Hard Things/Thibaut Meurisse/Wisdom Tree/B098mhbf23/English , A Glossary Of Literary Terms/M.H. Abrams Andgeoffrey Galt Harpham/Cengage India Private Limited/978-8131526354/English , The Art Of Spending Money: Simple Choices For A Richer Life/Morgan Housel/Macmillan/978-1804093696/English , You Become What You Think: Master Your Mind, Master Your Life/Shubham Kumar Singh/Penguin Business/978-0143475279/English , Courage To Be Disliked, The: How To Free Yourself, Change Your Life And Achieve Real Happiness/Ichiro Kishimi And Fumitake Koga/Allen & Unwin/978-1760630720/English , As You Like It/William Shakespeare/Fingerprint Publishing/978-9356524262/English , The Cherry Orchard/Anton Chekhov/Sanage Publishing House Llp/978-0486266824/English , Indias Most Fearless/Aroor Shiv/Penguin Random House India/978-0143440444/English , One Hundred Years Of Solitude/Marquez Gabriel Garcia/Penguin Random House India/978-0198743514/English , Certificate Physical And Human Geography/Leong Goh Cheng/Oxford University Press/978-0195628166/English , Life Is What You Make It/Shenoy Preeti/Srishti Publishers & Distributors/978-9552098987/English , How To Talk To Anyone - Master The Art Of Communication/Leil Lowndes/Harper/978-0007272617/English , India Since Independence/Chandra Bipan/Penguin Random House India/978-0143104094/English , Believe In Yourself/Murphy Joseph/Manjul Publishing House Pvt Ltd/978-8183225090/English , Thus Spoke Chanakya - Ancient Wisdom For Daily Inspiration/Pillai Radhakrishnan/Jaico Publishing House/978-9386867544/English , Satyayoddha Kalki/Missal Kevin/Prakash Books India Private Limited/978-9388369152/English , Lifes Amazing Secrets - Finding Happiness/Das Gaur Gopal/Penguin Random House India/978-0143442295/English , Ghosts Of The Silent Hills/Anita Krishan/Prakash Books India Private Limited/978-9389717136/English , The Castle Of Otranto/Walpole Horace/Sanage Publishing House Llp/978-8196160418/English , Ruskin Bond Horror Omnibus/Bond Ruskin/Rupa Publications India Pvt. Ltd/978-8129112552/English , One Indian Girl/Bhagat Chetan/Rupa Publications India Pvt. Ltd/978-8129142146/English , The Monk Who Sold His Ferrari - Monk Sold His Ferrari/Sharma Robin S./Jaico Publishing House/978-8179921623/English , Me Before You - Me Before You/Moyes Jojo/Penguin Books Ltd/978-0718157838/English , Dark Horse/Mrinal Nilotpal/Hind Yugm/978-9386850591/English , The Immortals Of Meluha/Amish Tripathy/Harper360/978-9356290525/English , The Chola Tigers: Avengers Of Somnath - A Historical Fiction By Amish/Amish Tripathy/Harpercollins Publishers/978-9369896097/English , Same As Ever/Morgan Housel/Harriman House/978-1804090947/English , Pearson Nta Ugc Net 2025 Paper 1/Kvs Madaan/Pearson Education/B0f4wvj28z/English , 1232 Km : The Long Journey Home/Vinod Kapri/Harpercollins Publishers India/978-9354226519/English , Stars Will Guide You Home/Stuti Changle/Harpercollins Publishers India/978-9369890651/English , Ponting : At Close Of Play/Ricky Ponting/Harpercollins Publishers India/978-9351160717/English , The Power Of Curiosity/Anita Karwal/Harpercollins Publishers India/978-9356296671/English , What To Think About Machines That Think/John Brockman/Harpercollins Publishers India/978-0062425652/English , Daiva : Discovering The Extraordinary World Of Spirit Worship/K. Hari Kumar/Harpercollins Publishers India/978-9354899744/English , Pursuit Of Happyness/Chris/Jones Gardner/Harpercollins Publishers India/978-0060744878/English , India’S Wars Ii : A Military History 1972-2020/Arjun Subramaniam/Harpercollins Publishers India/978-9365696325/English , Hitler And India/Vaibhav Purandare/Harpercollins Publishers India/978-9356293151/English , Tagore In Tripura/Khagesh Dev Burman/Harpercollins Publishers India/978-9369895250/English , Ramayanam : Khand 1/Dushyanth Sridhar/Harpercollins Publishers India/978-9362136039/English , 14 : Stories That Inspired Satyajit Ray/Bhaskar Chattopadhyay/Harpercollins Publishers India/978-9351361930/English , Revolutionaries : The Other Story Of How India Won Its Freedom/Sanjeev Sanyal/Harpercollins Publishers India/978-9356295940/English , 11 Rules For Life : Secrets To Level Up/Chetan Bhagat/Harpercollins Publishers India/978-9356999978/English , Lockwood & Co./Jonathan Stroud/Penguin/978-0241613122/English , On The Open Road/Stuti Changle/Penguin/?978-0143453680/English , Shivaji : The Great Maratha/Ranjit Desai/Harpercollins Publishers India/978-9352774395/English , An Ordinary Life : Portrait Of An Indian Generation/Ashok Lavasa/Harpercollins Publishers India/978-9354223174/English , Attitude Is Everything/Jeff Keller/Harpercollins Publishers India/978-9351772071/English , I Came Upon A Lighthouse : A Short Memoir Of Life With Ratan Tata/Shantanu Naidu/Harpercollins Publishers India/978-9354897412/English , Why Not Me? A Feeling Of Millions/Anubhav Agrawal/Harpercollins Publishers India/978-9390351473/English , Write Me A Love Story/Ravinder Singh/Harpercollins Publishers India/978-9354223204/English , The Troubled Deep/Rob Parker/Bloomsbury Publishing/B0d81gzsbj/English , The Last Murder At The End Of The World/Stuart Turton/Bloomsbury Publishing/978-1526634924/English , Twelfth Fail : Hara Vahi Jo Lada Nahi/Anurag Pathak/Harpercollins Publishers India/B09nl46tts/English , Days At The Morisaki Bookshop:/Satoshi Yagisawa/Manilla Press/978-1786583239/English , Indias Near East/Avinash Paliwal/Penguin/978-1805260615/English , Incredible History Of Indias Geography/Sanyal Sanjeev/Penguin Books Limited/978-0143333661/English , Stalingrad/Antony Beevor/Penguin Books Limited/978-0141032405/English , The Last Kids On Earth And The Nightmare King/Max Brallier/Egmont/978-1405295116/English , The Microsoft Story/Dan Good/Harpercollins Publishers India/978-1400223909/English , A Samurai Dream Of Azad Hind: Rash Behari Bose/Prasun Roy/Vitasta Publishing Pvt.Ltd/978-9390961849/English , Before I Forget: A Memoir/M.K. Raina/Vintage Books/978-0670098811/English , His Last Bow/Arthur Conan Doyle/Fingerprint Publishing/978-9354406256/English , Ai Snake Oil/Arvind Narayanan, Sayash Kapoor/Penguin/978-0691249131/English , The Thousand Autumns Of Jacob De Zoet/David Mitchell/Sceptre/978-0340921562/English , Battles Of Our Own/Mohanty Jagadish/Penguin Modern Classics/978-0143451747/English , The Power Of Letting Go/John Purkiss/Octopus Books/978-1783253630/English , The Light Of Love And Other Stories/Ashutosh Agnihotri/Har-Anand Publications Pvt Ltd/978-8196403959/English , Wings Of Valour : True Stories Of The Indian Air Forces Daring Operations/Swapnil Pandey/Harpercollins India/978-9369891733/English , The Eleventh Hour/Salman Rushdie/Penguin Hamish Hamilton/978-1787336049/English , The In-Laws/James Caine/India Penguin/979-8835781669/English , Call It Coincidence/Nona Uppal/Penguin Ebury Press/978-0143471547/English , Crossing Over/Kaushik Mitra/India Penguin Enterprise/B0frzjggvt/English , The Loneliness Of Sonia And Sunny/Kiran Desai/Penguin Hamish Hamilton/978-0307700155/English , Flesh/David Szalay/Jonathan Cape/978-0224099790/English , Tomb Of Sand/Geetanjali Shree/Penguin/978-0143448471/English , Eileen/Ottessa Moshfegh/Penguin Group Usa/978-0143128755/English , A Plane Story/Anmol Malik/Harpercollins India/978-9354890246/English , Too Good To Be True/Prajakta Koli/Harper Fiction/978-9365693393/English , The India Way : Strategies For An Uncertain World/S. Jaishankar/Harpercollins Publishers India/978-9394407213/English , Pride And Prejudice/Jane Austen/Fingerprint! Publishing/978-8172344504/English , Playing It My Way/Sachin Tendulkar/Hodder & Stoughton/978-1473605176/English , Can We Be Strangers Again?/Shrijeet Shandilya/Penguin Ebury Press/978-0143475927/English , After The Storm/Lakshmy Ramanathan/Harpercollins India/978-9353020286/English , Tara Goes Aahhhhh/Sam Dalrymple/Harper Childrens/978-9365693508/English , Youth And Truth : Unplug With Sadhguru/Sadhguru/Harpercollins India/978-9354895401/English , An Ordinary Life : Portrait Of An Indian Generation/Ashok Lavasa/Harpercollins/978-9354223174/English , The Journey To Adi Kailash/K. Ramachandran/Penguin Ebury Press/978-0143461340/English , In An Antique Land/Amitav Ghosh/Penguin India/978-0143066491/English , Tales Of The Open Road/Ruskin Bond/Penguin India/978-0144000722/English , Diary Of A Young Girl/Anne Frank/Penguin/978-8172345198/English , 1984/George Orwell/Fingerprint! Publishing/978-8192910901/English , Animal Farm/George Orwell/Penguin India/978-0143416319/English , Sapiens: A Brief History Of Mankind/Yuval Noah Harari/Penguin Random House/978-0099590088/English , Midnights Children/Salman Rushdie/Random House Trade Paperbacks/978-0812976533/English , The Glass Palace/Amitav Ghosh/Harpercollins/978-0008279486/English , The Inheritance Of Loss/Kiran Desai/Grove Press/978-0802142818/English , A Tale Of Two Cities/Charles Dickens/Pan Macmillan India/978-1509848997/English , Learn, Don’T Study/Pramath Raj Sinha/Penguin Business/978-0670097487/English , The Room On The Roof, Vagrants In The Valley/Ruskin Bond/Penguin India/978-0140239591/English , The Guide/R.K. Narayan/Indian Thought Publications/978-8185986074/English , The Tripua Language/Prof. Deb Dulal Tripura/Prof. Deb Dulal Tripura/Latest/English , In A Forest, A Deer/Ambai/Oxford University Press/978-0198080015/English , English, August: An Indian Story/Upamanyu Chatterjee/Faber & Faber/978-0571345892/English , Sunlight On A Broken Column/Attia Hosain/Penguin India/978-0143066484/English , The Heart Has Its Reasons/Mehak And Kripanarayan/Katha,India/978-8187649540/English , Year Of The Tiger/Sohaila Abdulali/Penguin Books India - Penguin/978-0143067856/English , Things Fall Apart/Chinua Achebe/Rhus/978-0385474542/English , Last Man In Tower/Aravind Adiga/Atlantic Books/978-1848875180 /English , Untouchable/Anand/Pearson Education India/978-8131707258 /English , Why We Dont Talk/Shinie Antony/Rupa/978-8129116529/English , Life After Life/Kate Atkinson/Black Swan/978-0552776639/English , When I Hid My Caste/Baburao Bagul/Speaking Tiger Books/978-9386702951/English , The Enemy Within/Bani Basu/Orient Blackswan/978-8125016687/English , This Side Of Paradise/F. Scott Fitzgerald/Penguin/978-0141185576/English , Flood Of Fire/Amitav Ghosh/Penguin Books India/978-0143426127/English , Time Travel/James Gleick/Fourth Estate/978-0007544455/English , Dune/Frank Herbert/Penguin Usa/978-0441172719/English , Partitions/Kamleshwar/Penguin India/978-0143063704/English , Dear Life/Alice Munro/Vintage/978-0099578635/English , Fathers And Sons/Ivan Turgenev/Notion Press/978-1639044481/English , Monkey-Man/K. R. Usha/Penguin India/978-0143068563/English , The Invisible Man/H. G. Wells/Scholastic/978-1365700729/English , Inside The Box: A Proven System Of Creativity For Breakthrough Results/Drew Boyd/Simon & Schuster/978-1451659290/English , The Artist In The Machine: The World Of Ai-Powered Creativity/Arthur I. Miller/The Mit Press/978-0262042857/English , Design Your Thinking/Soni Pavan/Penguin Random House India Private Limited/978-0670094097/English , Turning Points : A Journey Through Challenges/A.P.J Abdul Kalam/Harper India/978-9350293478/English , What I Did Not Learn At Iit-Special/Rajeev Agarwal/Random House India/978-8184007619/English , A Modern Approach To Verbal & Non-Verbal Reasoning/R.S. Aggarwal/S Chand Publishing/978-9352832163/English , Connect The Dots/Rashmi Bansal/Iim/978-8190453028/English , Poor Little Rich Slum/Rashmi Bansal/Westland/978-9381626184/English , And The Lion Smiled At The Rabbit/Rashmi Datt/Wisdom Tree/978-8183282543/English , Power Of Habit/Charles Duhigg/Random House Books/978-1847946249/English , Youre Hired/Nasha Fitter/Penguin India/978-0143100577/English , Olive Kitteridge/Elizabeth Strout/Random House Trade Paperbacks/978-0812971835/English , Collective Choice And Social Welfare/Amartya Sen/Penguin/978-0141982502/English , Impossible To Possible/R.C. Bhargava/Bloomsbury India/978-9356405301/English , Annihilation Of Caste/B.R. Ambedkar/Navayana/979-8511230634/English , The Thursday Murder Club/Richard Osman/Penguin Books/978-1984880987/English , Annie On My Mind/Nancy Garden/Square Fish/978-0374400118/English , Akata Witch: 1/Nnedi Okorafor/Penguin Usa/978-0670011964/English , Bamboo People/Mitali Perkins/Charlesbridge/978-1580893299/English , Attack On Titan 1/Hajime Isayama/Kodansha Comics/978-1612620244/English , The Battle Of Jericho/Sharon M. Draper/Atheneum/Caitlyn Dlouhy Books/978-1481490290/English , Fault In Our Stars/John Green/Penguin/978-0141345659/English , Forever/Judy Blume/Macmillan Childrens Books/978-1447281047/English , Jacob Have I Loved/Katherine Paterson/Harpercollins Childrens Books/978-0064403689/English , Jumped/Rita Williams-Garcia/Quill Tree Books/978-0060760939/English , Separate Peace/John Knowles/Scribner/978-0743253970/English , The 57 Bus/Dashka Slater/Wren & Rook/978-1526361233/English , Six Months To Live/Lurlene N. Mcdaniel/Darby Creek Publishing/978-1581960037/English , We Are Okay/Nina Lacour/Dutton Books For Young Readers/978-0525425892/English , We Were Liars/E. Lockhart/Hot Key Books/978-1471418761/English , Of Mice & Men/John Steinbeck/Penguine/978-0141185101/English , The Happiness Equation/Neil Pasricha/Random House/978-1785041204/English , Brain Rules/John Medina/Pear Press/978-0983263371/English , Physics Of The Impossible/Michio Kaku/Anchor/978-0307278821/English , Eleven Minutes/Paulo Coelho/Harpercollins Publishers/B0cyblyh9m/English , The Tattooist Of Auschwitz/Heather Morris/Harpercollins/978-0062797155/English , Paper Moon/Rehana Munir/Harpercollins India/978-9353574000/English , Johnny Gone Down/Karan Bajaj/Harpercollins India/978-9352642915/English , The Lovely Bones/Alice Sebold/Picador/978-0330485388/English , Anna Karenina/Leo Tolstoy/Penguin/978-0140449174/English , Into The Wild/Jon Krakauer/Vintage Books/978-0385486804/English
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 4
37.
Educational and Research Institute #9688135 AOC
Tender For Supply, Installation And Commissioning Of Devices, Equipment, Instrument, Machineries, Tools Etc. For Different Vocational Courses Of Jalpaiguri And Alipurduar Districts At Jalpaiguri Polytechnic Institute. , Digital Compression Testing Machine : : Compression Testing Machine, Capacity 2000Kn, Digital Confirm Is - 4858 ( 2000) With Nccbm Certified Load Gauge. With Nabl/Nccbm Certificate , Theodolite Transit Latest Model With All Accessaries : : Image Erectlength 78 Mmmagnificaton 25Xeffective Aperture 38Mmfield Of View 2.6 M At 00Mshort Focus .5Mstadia Ratio :00Stadia Constant 0Resolving Power 4Circle Diameter Hz3mm, V00 Mmgraduation 0Vernier Reading 0Plate Level Sensitivity 45 / 2Mmvertical Circle Level / 2Mmwith Stand, Plumb Bob And Cover , Aggregate Impact Tester With Cylindrical Cup And Measuring Cylinder : : Aggregate Impact Test For Determining The Aggregate Impact Value And In Accordance With Test Procedure As In 2386 Part Iv Reaffirmed In 20, Is:9377 - 979. Along With Supply Of Is Sieve (Spec Mentioned As In [Bis:460 Part I & Ii 985, Reaffirmed 2008]) Size 2.5, 0 And 2.36 Mm , Auto Level Latest Model With All Accessaries : : Leveling Accuracy: ±0.7Mmtelescope Magnification: 32X; Minimum Focus Distance: 0.2M From End Of Telescope, 0.3M From Instrument Centerautomatic Compensatorhorizontal Angle Measurementworking Range : 00M Angular Accuracy: °Field Of View: ° 30 Or 2.6Ft@00Ftmin. Focus Distance: -Ftcompensator Range: +/-5Comp Setting: ±0.3 , Hand Gps-Latest Version : : Worldwide Basemap2.2 65K Color, Sunlight-Readable Display3-Axis Compass And Barometric Altimeterwireless Capability To Share Waypoints, Routes And Geocaches With Other Similar Devices · Gps And Glonass Satellites For Faster Positioningdisplay Size, Wxh: .4 X .7 (3.5 X 4.4 Cm); 2.2 Diag (5.6 Cm) Or Moredisplay Resolution, Wxh: 76 X 220 Pixelsdisplay Type: Transflective, 65-K Color Tftbattery: High Capacity Nimh Or Lithium Battery Life: 25 Hours Or Morehigh-Sensitivity Receiver; Usb Interface With Base Map;Built-In Memory .7 Gb Or More, Capabilities Of Accepting Microsd Card Waypoints/Favorites/Locations: 2000 Points, Having Photo Navigation (Navigate To Geotagged Photos) Capabilities , Mortar Cube Vibrator : : 2000±400Rpm , Aggregate Crushing Value Apparatus : : Best Quality - Cylindrical Cell: 20 Mm Internal Dia X 50 To 20 Mm Heightplunger: 50 Mm Dia X 00 To 5 Mm Heightbase Plate: 200 To 220 Mm Square X 7 Mm Thicknesstamping Rod: 5 Mm Dia X 450 To 600 Mm Lengthmetal Measure: 20 Mm Internal Dia X 80 Mm Height , Concrete Mixer : : Drum Capacity: 500 Lpower Source: Electricautomation Grade: Manualoutput Capacity : 200 L , Dumpy Level : : Length: 25Mm, Objective Aperture: 32Mm(.26In. ), Magnification: 24X, Resolving Power: 4, Image: Erect, Resolving Power: 4.0, Field Of View: ° 25 (2.5M/8.2Ft. ), Minimum Focusing Distance: 0.2M (7.9In. ) From End Of Telescope0.3M (Ft) From Instrument Center, Image: Erect, Reticle Pattern: Cross Line, Stadia Constant:0, Stadia Radio:00, Focusing Knob:-Speed, Sight Aid: Gun Sight , Manual Bar Bending Machine Of Suitable Size : : Bar Dimensions: 920*920*200 Mmmax Bending Radius: 0-50 Mm , Bulk Density Apparatus(Cylindrical Measure For Fine Aggregate And Coarse Aggregate ) : : Is: 2386 (Part - Iii) -963, Is: 0079-982 , Turbidity Test Kit : : Turbidity Range: 0.00 To 9.99; 0.0 To 99.9; 00 To 000 Ntuturbidity Resolution: 0.0; 0.; Ntuturbidity Accuracy: ±2% Of Reading Plus 0.02 Ntuturbidity Repeatability: ±% Of Reading Or 0.02 Ntu, Whichever Is Greater , Power Cutter Of Suitable Size : : Blade Size: 355 Mm*25.4 Mmno-Load Speed: 4800 Rpmmax Cutting Depth: 20 Mm , Box Sextant : : Packaging Type: Boxsize: 3 * 3 * .75Material: Ss , Planimeter : : Digital , Plane Table With Stand, Accessories & Water Proofing Cover : : Plane Table Board: 600 X 750 X 22 Mmplane Table Stand: Wooden/Teak Wood/ Aluminiummagnetic Compass: 50 Mm Brassspirit Level: 50 Mm Brass/ Aluminiumalidade/Sight Vane: Isi Specificationplumbing Fork: Aluminuim/Brassplumb Bob : Steel / Brasscanvas Cover: Full , Weighing Plateform Digital : : 00 Kg. Accuracy Kg. , Vicat Apparatus With Plunger, Needles And Mould : : Vicat Apparatus With Isi Certification Mark Is:553 , Standard Is Sand : : Garde: Finebulk Density: 520 To 680 Kg/M3 , Oven : : Temperature Range: 5°C Above Ambient To 250°C Maximumtemperature Accuracy: + / - 2°C , Electronic Balance : : 30Kg - Gram L.C , Tile Cutter : : Hand Operated , Bar Bending Table : : As Per Availability , Drill And Bit Set : : Item Dimension: 330Mm X 232Mm X 72Mm , Ratchet Rack : : With Post And Clamp Flat 5 Drill 6 To 35 Mm By 0.2 Mm. , Mortar Board : : 2000 X 2000 , Metal Cross Staff- Box Type : : Cross Staff Material: Woodenpole Material: Mild Steel , Telescopic Alidade : : Height: 5-6 Inchdiameter Of Lens: 3Mmlength: Upto2 Inchvisible Range: -4 Km , Slump Test Apparatus With Temping Rod : : Slump Test Apparatus Is: 7320-974 With Nabl / Nccbm Certificate , Water Testing Kit - For Ph Value : : Range: -4Number Of Tests: 500 , Thickness And Length Gauges (Elongation And Flakiness Index) : : Thickness Gauge Constructed From Heavy Gauge Sheet Steel With Isi Certification Mark, Is:2386 (Part ):963 , Plumbers Metal Melting Pot : : 0 Kg. , Metal Cross Staff- Open Type : : Material: Brassweight (Kg): Kgsize: 0 Inch (Diameter) , Ratchet Pipe Die : : 5 Mm To 32 Mm , Tap And Die Set To Cut Bsp Thread : : Size: Mm To 00 Mmmaterial : Ss, Mspack Type: Box , Height Indicators : : Length: 0 Feettotal Height: 0 Feet , Metric Chain- : : Metric Chain: Consisting Of A Fixed Number Of Straight Links Of Galvanised Mild Steel Wire 4 Mm In Thickness, The End Of Each Link Are Bent Into A Loop And Connected Together By Means Of Three Circular Shape Rings. The Joints Of Rings May Open Or Welded Preferably Welded. The Ends Of The Chain Are Provide With Brass Handles Which Is Linked With The Chain By Swivel Joints; Length Of The Link Is 200 Mm, Each Meter Is Provided With With A Circular Brass Ring And Each Five Meter Length Is Provide Brass Tallies Of Requisite Shape. Each Chain Should Be Provided With 5 Nos Of M.S. Arrows Of 4 Mm Diameter Bar And 40 Cm Height. Refer: Is: 492-970 - 30 M Length , Prismatic Compass With Stand And All Accessaries : : Size: 4/6 Diameter With Telescopic Aluminium Folding Stave; Material: Of Stainless Steel/Gunmetal/Nonmagnetic Metal,Can Be Packed In A Leather Case With Teak Wood Tripod Stand . , Chain Pipe Wrenches : : 90 Mm-650 Mm , Engineers Chain : : Range: 20 Metrefinishing: Galvanizedmaterial: Ironcolor: Silver , Sieve For Sand In Adjustable Stand : : As Per Bis: 383 970 Sieve Brass Frame With Sieves , Optical Square : : Should Be Consists Of Brass/Suitable Metal Hollow Box Having Open Face About 6 X 3 Cm And Closed About 2 X 3 Cm And Deep About 4 Cm To 5Cm. Provided With A Brass Handle About 8 Cm In Length. Two Mirrors Fixed At An Angle Of 45 Degrees To The Inclined Sides Of The Box. , Mortar Board : : 2 Mtx2 Mt. , Slump Cone : : Material: Mild Steelheight: 300Mmslum Cone Top Dia: 00 Mm , Is Brass Sieves - Set : : 4.75Mm,2.36Mm, .8Mm, 600Micron, 300 Micron, 50 Micron, 90 Micron, 75 Micron, 45Micron, Pan And Cover , Stillson Pattern Pipe Wrenches : : 450 Mm To Take Pipe Up To 52 Mm Dia. , Pipe Vice To Grip Pipes Up To : : 77 Mm. , Drawing Board : : 000Mmx700mm , Brushes For Painting : : Size: 2 Inchbrush Head Shape: Flat , Leveling Staff - : : 5 Meter 5 Section Complete In Full Aluminum In Best Quality With Water Proof Canvas Cover. , Ranging Rod Steel : : 2 M , Offset Rod : : 2 M , Measuring Cylinder : : Set Of 00 Ml., 500 M., 000 Ml. , Pick Axe : : Material: Mild Steelsize: 6 Inch , Pyconometer For Specific Gravity : : Pyknometer 50 Ml For Specific Gravity Bottle, Dimension 50X50x00 Mm , Weight- 0.05 Kg , Pickaxe. : : Material: Mild Steelsize: 6 Inch , Le Chatelier Mould (For Soundness Test Of Cement) : : 30 Mm In Diameter, With 30 Mm Height And 50 Mm In Length From A Special Alloy Material Is Produced By Combining The Two Branches. The The Le Chatelier Soundness Test Set Should Be Supplied Complete With Le Chatelier Moulds 3 Pcs.• 50X50 Mm Glass Plates 6 Pcs.• 300 Gr Weights Pcs.• 00 Gr Weight, 3 Pcs.• Tamping Rod 7 Mm Dia. X 70 Gr• Steel Ruler• Plastic Carrying Case , Survey Plotting Scale- : : 8 Scales With Offset Scale In Box , Mason Square : : 30X60 Cm , Tenon Saw, Dovetail Saw : : Sizw: 2 Inchpoints: 3 Points Per Inch;Material: Carbidemaximum Cutting Depth: 50 Mmnumber Of Teeth: 6-2Bore Diameter: 80 Mm , Le Chateliers Flask (For Specific Gravity Testof Cement) : : Le Chatelier Flasks(Is 554 (996)) With A 250 Ml Capacity And A Graduated Neck That Can Be Used To Determine The Specific Gravity Of Hydraulic Cement, Sand, And Other Fine Materials. The Neck Should Be Graduated From 0 To Ml And From 8 To 24 Ml In 0. Ml Subdivisions, With An Additional 0. Subdivision Below The 0 And Above The .0 Ml Mark. The Flask Should Also Have An Oval Bulb In The Neck That Holds 7 Ml And A Number 3 Stopper. , Monkey Plier (Gas Pliers) : : Size: 0 Inch , Aluminum Float : : Material: Aluminumblade Material: Aluminumwidth: 8 Inchcapacity: 200 Sq.Mtr , Tool Caulking : : Set Of 2 , Flat Smithy Tong. : : Length: 250 Mmmaterial: Ss , Saw Plumber : : 300 Mm , Stop Watch : : Time Display: Digitalmaterial: Abs , Screw Driver Set : : 00 Mm To 300 Mm , Land Measuring Steel Tape : : 30 Mt Long , Brick Hammer With Handle : : Material: Mild Steelweight: 50 Gm , Crow Bar : : 30Mm Dia .5 M Long Of Mild Steel , Cube Mould : : 50 Mm Size , Spanner Monkey : : Up To 50 Mm , Stilson Wrench : : 200 & 350 Mm , Land Measuring Plastic Tape : : 30 Mt Long , Shovel : : M Long, 20Mm Dia , Spade : : Iron , Telescopic Pipes / Props : : Material: Steelouter Diameter: 6 Inchdiameter: 7 Mmsurface Type: Color Galvanized , Mason Plumb Rule With Spirit Level : : Size/Dimension: 5 Inch (Length);Length: 30 Cm / 300 Mm / 2 Inchtype: Single Columnaccuracy: 0.75 Mm/M , Trowel : : 25 Cmx0cm , Plumb Rule And Bob : : 2 Set , Non Porous Plate : : Standard Size: 000 Mm* 500 Mm, 600 Mm * 600 Mm , Graduated Cylinder : : Material: Borosilicate , Adjustable Spanner : : A 375 , Double Face Hammers : : Material: Ironhandle: Wooden , Hacksaw Frame Adjustable : : 250 To 300 Mm , Level Spirit Wooden : : 300 Mm , M.S Pan : : 45 Cm Dia. , Bucket G.I. : : 35 Cm Dia. , Sprit Level : : 30 Cm Long , Bolster : : Filling Material: Cottondesign/Pattern: Plain , Wooden Mallet : : 24.5 Cm Long, .54 Kg , Gauging Trowel : : Handle Material: Plasticsize/Dimension: 2Material: Steel , Sampling Scoops : : 2Kg And 5 Kg , Plumbers Ladle : : Material Grade: Ss 202Size: 2 , Trowel 25 : : Material: Stainless Steelblade Material: Stainless Steel 202Size: 250 Mm * 25 Mm , Farma Of Mild Steel For Measuring Aggregate : : Heaving Volume 0.03472 Cm , Masonry Grinder : : No Load Speed: 000 Rpmvoltage: 220/230V , Cutter, Pipe Wheel Type : : 6 Mm To 25 Mm. , Caliper Outside : : 5O Mm , Steel Tapes : : 5 Mt Long , Hammer Ball Peen : : 800 Gms. , Cutting Pliers : : Size: 8 Inch , Inside Caliper : : 50 Mm , Pointing Trowel : : 6 , Steel Float : : Material: Stainless Steelmounting Type: Top Mount , Measuring Tape : : 5 Mtr. (Steel) , Bar Bending Lever (Suitable Diameter And Length) : : In M , Float Wooden : : Material: Woodmounting Type: Top Mount , Chiesel : : Different Suitable Sizes , Plumb Bob : : 50 Gms. , Bending Pipes (Suitable Diameter And Length) : : In M , Line Pin Corner Block : : Weight: Kg.Size: 800 Mm , Wire Brushes : : Bristle Length: 2 Inchbrush Size: 5 Inch , Bending Pipes : : Suitable Dia& Length In M , Total Station Latest Model With All Accessaries : : Worldwide Basemap2.2 65K Color, Sunlight-Readable Display3-Axis Compass And Barometric Altimeterwireless Capability To Share Waypoints, Routes And Geocaches With Other Similar Devices · Gps And Glonass Satellites For Faster Positioningdisplay Size, Wxh: .4 X .7 (3.5 X 4.4 Cm); 2.2 Diag (5.6 Cm) Or Moredisplay Resolution, Wxh: 76 X 220 Pixelsdisplay Type: Transflective, 65-K Color Tftbattery: High Capacity Nimh Or Lithium Battery Life: 25 Hours Or Morehigh-Sensitivity Receiver; Usb Interface With Base Map;Built-In Memory .7 Gb Or More, Capabilities Of Accepting Microsd Card Waypoints/Favorites/Locations: 2000 Points, Having Photo Navigation (Navigate To Geotagged Photos) Capabilities , Dgps-Latest Version : : Main: The Gnss System Should Have Cutting Edge Technology With Receiver & Controller. The Gnss System Should Have Separate Receiver And Controller. The Receiver Should Capable Of Track Multi Frequency Satellite (L/L2/L5/Mss) Signals. Each Receiver Should Have Connected With Controller Through Bluetooth. Each Receiver Should Have Supports All Global Gnss Systemsspecification Of Antennasingle Tracking :Should Be Enable Propoint Gnss Positioning Technology For Improved Accuracy And Productivity In Challenging Conditions-Gps: Lc/A, L2c, L5glonass: Lc/A, L2c/Asbas: Lc/A, L2c, L5 Galileo: E, E5a Beidou: B, B2aqzss: Lc/A, L2c, L5navic (Irnss): L5no Of Channel: 550 Or More (Physical Channel Or Dynamic Digital Channel Be Accepted)Modes Of Survey: Network Rtk, Real Time Extension, Fast Staticaccuracycode Differential (Dgps) Gnss Positioninghorizontal: 0.3M+Ppmvertical: 0.6M+Ppmnetwork Rtkhorizontal: 0 Mm + 0.5 Ppmvertical: 20 Mm + 0.5 Ppmreal Time Extension (Rtx)Horizontal: 2 Cm Rmsvertical: 5 Cm Rmscommunications/ Connectivity :Bluetooth 4.2 Or Betterusb Power Supply Portdata Protocols: Ntrip, Vrs, Rtcm, Cmrx, Dcolposition Output: Nmea, Dcol Through Location Service.Battery And Power : Battery Should Be Capable To Installed In External Usb- Apower Consumption: Not More Than 2.5 Wweight: Not More Than 400 Gms.Positioning Rate: 0Hzoperational Tempurature: -20O C To +60O Cstorage Tempurature:- 40O C To +70O Cdust & Water Protection: Ip 65 Or Betterhumidity : Upto 00%, Non-Condensingshock Proof : M Or More On To Hard Surface/Concrete.Specification For Controllertype : Scratch-Resistant, Touch-Screen Display, Highly Readable In Both Low Light And Glaring Sunshine.Operating System: Android 0 Or Better / Windows 0 Or Betterprocessor: Qualcomm Processor Or Betterweight: Not More Than .0 Kgcamera & Gps: 3 Mp Or More Resolution With Autofocus And Led Flash Inbuilt Gps With Geo -Tagging Facility.Display: 5 Vga Display Lcd Tft, Sunlight Readable, Back Lite Led,Graphical Display: Controller Should Be Capable Of Creating Complete Points, Lines In The Field Whichwill Be Displayedkeyboard: Full Qwerty Key Pad Hard With Numeric Keyboard For Numbering & Function Short Keysmemory: Ram 4 Gb Or More, Internal Memory 64 Gb Or More, External Through Sd Cardbattery : More Than 0-5 Hours On Operation Condition On A Single Chargeoperation: -30Oc To +60Oc Or Betterstorage: -30 C To +70 C Or Bettercommunication & Feature: Type C Portintegrated Quad-Band Gsm/Gprs/Edge Integrated Bluetooth Integrated Wi-Fi 3 Mp Auto Focus Camera With Dual White Light Led Flash, Led Flashlight Function Integrated Compass With Geo Tagged Imagesintegrated Accelerometer Sbas Supportdust & Water Protection : Lp65 Water Proof And Dust Proofdrop: M Or Betteraccessories, Hardware And Software For Basereceiver :Cable: Rechargeable Battery With Charger:22M Carbon Fiber Pole (Flat Top For Thread Less Mount):Accessories, Hardware And Software For Roverreceiver :Cable: Rechargeable Battery With Charger:22M Carbon Fiber Pole (Flat Top For Thread Less Mount):Field Software:Controller Mount Bracket: , Motorised Sieve Shaker : : Sieve Shaker, Motorisedhaving As Tardy Cast Iron Body, The Shaker Has An Inclined Sieve Table Which Can Accommodate A Max Of Seven Sieves Of 200 Mm Dia. N Adjustable Top Clamping Plate Is Provided To Hold The Sieves. The Table Has Agyratory Motion In Addition To Up And Down Jolting Action. The Operating Gear Assembly Is Enclosed In An Oil Bath Fitted With Transparent Oil Level Indicating Window. Suitable For Operating On 220V, 50Hz, Single Phase Supply.Time Switch Adjustable From 0-60 Minutes.Lid And Receiver For 200 Mm Dia Sieves, Made Of Brass.Adopter For 300 Mm Dia Sieves , Floor Polishing Machine : : Motor Power: 700 Wattbrush Diameter: 7 Inchbrush Speed (Rpm): 55 Rpmmotor Rating: 2 Hp , Concrete Vibrator : : Pin Type & Plate Type , Electric Drilling Machine : : 6 To 35 Mm By 0.2 Mm. For Drilling , Power Operated Cutting Machine : : Power Consumption: Single Phasecutting Blade Size: 0 Inchmachine Type: Semi -Automaticair Pressure: 5-8 Kg/Cm2dimension (L*W*H): 2600 * 600 * 650 Mm , Vibrating Machine : : Vibrating Machine Is:0080-982 The Machine Issued For Compaction Of 70.6 Mm Cube Specimens Of Cement Mortarunder Standard Vibration Required For Determination Of Compressive Strength Of Cement. The Vibration Machine Consists Of A Frame Mounted On Four Coiled Springs To Carry A Cube Mould And An Eccentric Revolving Shaft Mounted In Ball And Roller Bearings. The Machine Is So Balanced That The Eccentric Imparts Simple Harmonic Motion To Mould Carrier And The Mould. The Frequency Of Vibration Is 2000±400 Per Minute. The Drive From The Motor To The Eccentric Shaft Is Through An Endless Flat Belt Running On Crowned Pulleys. Suitable For Operation On 220V, 50Hz, Single Phase Supply. Supplied Complete With A Times Witch, One7.06 Cm I.S.I. Marked Cube Mould (Hc42.0.) With Hopper With Additional 2 Nos Of Belt. , Portable Hand Bender Of Suitable Size : : Tmt Bar Steel Dia.: 4-2 Mmbody Material: Msweight: 4 Kg , Spray Painting Machine : : Surface Finish: Polishedphase: 3 Phasevoltage: 220V , Drums : : 200 Liters Capacity , Polishing Machine : : Type: Scrubberbrush Diameter: 7 Inchpower Source: Electric , Abney Level : : Type: Double Columnaccuracy: 0.6 Mm , Electric Heater : : Material : Mild Steelpower: 500 Wpower Consumption: Kw- 3 Kw , Computing Scales Five Hectares : : , Gunters Chain : : Measuring Range: 20 Metersweight: 500 Gmfinishing Type: Powder Coatedmaterial : Stainless Steel , Offset Scale For Cadastral Survey : : , Computing Scales Two Hectares : : , Indian Pattern Clinometers : : Material :Brassweight: 3-4 Kilogram , Telescopic/ Adjustable Spans : : Material : Mild Steelusage/Application: Constructionsurface Type: Hot Dipped Galvanizedshape: Rectangularweight: 4 Kg , Straight Edge : : Stainless Steel , Steel / Plywood Shuttering Plates : : Thickness: /2 Inchcolor: Redwood Type: Plywoodcore Material: Eucalyptus , Hammer 5 Kg : : 5 Kg. , Water Tube : : 6 M , Hammer Kg : : Kg. , Magnifying Glass : : Material : Glasssize/Diameter: 3 Inchhandle Color: Sliverhandle Material: Metal , Marking Rope & Thread : : 5 M , Chisel Cold Flat : : 20 X 250 Mm , File Flat Rough : : 300 Mm , Electric Bulb Brooder : : Brooding Capacity-000Nos , Poultry Gas Brooder : : Chick Capacity-500-000 Nos. , Manual Pan And Jar Chick Drinker,3 Litre : : Bottom Plate Dia: 245 Mm, Capacity-20 Birdscapacity Of Chicks: 50 To 70Cone Height: 240 Mm , Hatching Machine Cum Incubator : : Capacity-000 Egg ,Automatic, Brand-Magnum,Fully Automatic Machine With Yr Replacement Guarantee And 3 Yr Service Warranty Can Hatch Any Type Of Bird Eggs 90-95% Hatching Guaranteed,Voltage-220-250 V, Warranty-3 Year000 Eggs Setter Plus 500 Hatcher , Manual Poultry Vaccinator : : Bird Type: Chickenmaterial: Metalweight: 00 Gm , Silver Hen Leg Bend, For Animal : : Color Silverusage/Application For Poultrymaterial Stainless Steelsize 4Inchfinishing Type Polishedset Contain 00 Pieces , Grower Feeder Linear : : Type Linearequipment Use Feedingcolour White And Redbird Type Growermaterial Plastic , Layer Feeder Linear : : Type Linearequipment Use Feedingcolour White And Redbird Type Layermaterial Plastic , Chick Feeder Linear : : Type Linearequipment Use Feedingcolour White And Redbird Type Chickenmaterial Plastic , Grower Feeder Round : : Bell /Round Type, Red ,Capacity-8 Nos , Layer Feeder Round : : Bell /Round Type, Red ,Capacity-8 Nos , Chick Feeder Round : : Capacity-20 Birds,Manual,Circular , Chick Drinker Round Shaped : : Capacity Litreautomation Type Automaticdrinker Type Bellcolour Red , Grower Drinker Round Shaped : : Bell Type, Red ,Capacity-8 Nos , Layer Drinkler Round Shaped : : Bell Type, Red ,Capacity-8 Nos , Brooder Guard : : Finishing Galvanizedusage/Application Brooding, Poultry Chick Guardmaterial Ironpackaging Type Rollsheet Thickness 0.5 Mm , Wing Bend : : Finishing: Polishedset Contain: 00 Piecesmaterial: Stainless Steel , Flame Gun 2Nos : : Length: 2Inchproduct Equipment Type: Flame Gunmaterial: Ms , Screw Gauge : : Real Instruments Aluminum Micrometer Screw Gauge Ss 0-25Mm, Mm-02 , Sphereometer : : Aterial Stainless Steelusage/Application Laboratoryproduct Shape Roundthickness 3Mm , Litter Racker Machine : : Usage/Application: Poultry Farmweight: 0Kg , Ai Gun For .2 Mm Straws With Volumetric System : : Volumetric Poultry Insemination Gun. Multi-Doses - For .2 Ml Poultry Straws , Poultry .2 Ml Straw : : Ref. 00559Ø 4. X Length 32 Mm For Poultry Semen . Packaging And Sales Unit3500 , Poultry Media : : Ready-To-Use Media For Fresh Poultry Semen. Made For The Dilution And The Preservation Of Semen. Available With Or Without Antibiotics.Packaging And Sales Unit400 , Left Leg-Holder For Hens : : , Right Leg-Holder For Hens : : , Ai Shelf For Hens : : , Poultry Catching Crate : : Capacity 50 Kgcolor Blue & Redusage/Application Storageshape Squarestyle Mesh , Vernier Calliper : : Digital Vernier Calliper, Material -Steel , Haugh Meter : : Material Poultryusage/Application Laboratorypackaging Type Boxdisplay Type Digitalbrand Orka , Refrigerator : : Capacity 500 Ltype Of Freezer Top Freezernumber Of Shelves 2Power Source Electricityvoltage 220 V , Egg Filler Flat Plasic And Cardboard : : Egg Storage Capacity 30, 30Capacity 00Gmsize 30*300*5Mmmaterial Virginusage/Application Poultry Farms , Nipple Drinker : : Equipment Use Feeding/Drinkingusage/Application Poultrytype Of Bird Chickendirection 360 Degreematerial Pp , Cow Hand Brush : : Plastic , Ear Tag Applicator For Plastic Ear Tags : : Brand Chadhamodel Name/Number Etasize Standardcapacity 50Color Red , Yellow Ear Tag Plastic Small, For Animal Farm : : Size 35X45mmcolor Yellowusage/Application Animal Farmmaterial Plasticmodel Name/Number Ear Tag Small , Stainless Steel ,Installation Castration Emasculator 9 Inch Imported : : Usage/Application Castrationmaterial Stainless Steelsize 9 Inchesautomation Grade Manualminimum Order Quantity 0 Piece , Stainless Steel Baby Burdizzo Castrator, : : Usage/Application Hospitalmaterial Stainless Steelautomation Grade Semi-Automaticproduct Type Veterinary Castratorlength 8 Inch , Stainless Steel Vet Digital Ai Gun : : Model Name/Number Standardusage/Application Veterinary Purposematerial Stainless Steelcolor Blackfeature Dgital Ai Gun , Milking Machine : : No Of Buckets .0Automation Grade Automaticmaterial Carbon Steelproductivity -0 Cows/Hourfinishing Mirror Polishing , Electric Motor Fresh Grass Gear Drive Chaff Cutter : : Cutting Capacity 400-600 Kg/Hrpower 3 Hppower Source Electric Motormachine Feed Fresh Grassspeed In Rpm 440 Rpm , Hoof Trimming Set : : Country Of Origin: Made In Indiabrand: Chamundapackaging Size: Each Pcs Single ( Set Having Three Pic) , Milk Feeding Bottle : : Equipment Use: Animal Feeding, Capacity-2 Ltr, Plasticcolor: Whitebrand: Cj Farms And Agritech , Milk Measure : : Available Capacity,00,200,500Ml & Ltr 50 Setusage/Application Dairybrand Chadhamaterial Ss 304Moc 304 Ss , Milk Strainer : : Usage/Application For Milkcolor Silvermaterial Stainless Steelsize 2Inchhandle Material Plastic , Mikking Pail Seamless : : Capacity 0 Lmaterial Stainless Steelcolor Silverusage/Application Milksurface Finished Polished , Feed Troley : : Load Capacity 00 Kgmaterial Mild Steelusage/Application Industrialtype Industrial Feeding Trolleycolor Any , Branding Equipment Set : : A To Z And (0-9)Manufacturer Name: Dotcom Pharmamaterial: Metal , Tattooing Equipment Set : : Country Of Origin: Made In Indiausage/Application: Professionalis It Portable: Portable , Bull Holder : : Material: Stainless Steelautomation Grade: Semi-Automaticsize: 6 Inches Without Chain , Bull Leader : : Color: Blackautomation Grade: Manualfinishing: Polished , Halter : : Country Of Origin: Made In Indiaanimal Breed: Cowpackaging Type: Poly , Artificial Insemination Crate Cum Travis : : Capacity Cowmilk Extraction Applicable To Cowautomation Grade Manualdesign Type Fixedbrand Patel Trunk , Casting Rope : : 5 Mtrs Apprx., 25 Mm, Natural Twisted Cotton Rope , Balling Gun : : Sage/Application : Animal Treatmentmaterial : Stainless Steelsize : 4 Inchautomation Grade : Manualis It Transparent : Non Transparentfeatures : Ssbrand : Chamunda , Mild Steel Cattle Mouth Gag : : Color: Silver And Bluematerial: Mild Steelautomation Grade: Manual , Clinical Thermometer : : Type: Mercury Thermometeraccuracy: 00 , I/V Infusion Set : : Capacity: 0 Mldrops Per Ml: 20 Drop/Mlliquid Filter: 0.2 M , Vaginal Spaculum : : Color Silvermaterial Alloybrand Sheensitem Dimensions L X W X H 2.99 X 5.9 X 2.56 Inches , Stethoscope : : Chestpiece Single Sideddiaphragm Single Piece Tunablechest Piece Finish Black , Automatic Vaccinator Or Vaccine Gun For Cattle : : Automation Type: Automaticcountry Of Origin: Made In India , Weight Balance : : Capacity: 200 Gmreadability:0.00 G ( Mg)Repeatability ( ± ): 0.00 Glinearity ( ± ): 0.002 G , Simple Microscope : : Monocular/ Binocular , Post Mortem Kit : : Categories: Cutting Instrumentssurface Treatment: Powder Coatedhandles: Steel , Syringe And Needle( 2Ml, 5 Ml, 0 Ml) : : Packaging Material: Labelsshelf Life: 5 Yearssterilization: Ethylene Oxide Sterilization , Cottone Gauge : : Size : 5Cm X 5Cmnumber Of Ply : 8 Plymaterial : Cottoncolor : Whitesterility : Non-Sterileusage/Application : Clinical , Trocar And Canula : : Usage/Application : Animal Treatmentmaterial : Metalsize : Total Length Is 4 Inch. Diameter Of Tip Is 0.80 Mm To 2 Mm.Product Type : Veterinarygrade : Surgical Grade Product , Wet And Dry Bulb Thermometer : : Color: Yellowheight: 320Mmlength: 80Mm , Hygrometer : : Display: Digitalmaterial Stuff: Plastictemperature Range: 5 Degree C To +50 Degree C (20 Degree F To 20 , Sparyer : : Brand: Shivampump Type: Battery Operated Sprayerusage/Application: For Spraying , Pouch Sealing Machine : : Automation Grade: Semi-Automaticpackaging Type: Pouchpower: 220Vmaterial: Stainless Steelorientation: Vertical , Pilfer Proof Cap Sealing Machine : : Material: Mild Steelno. Of Heads: Suitable Cap Dia: 28, 32, 43 , Hand Refractometer : : Minimum Scale: 0.2%Accuracy: +-0.2% , Weeder : : Type: Nail Typematerial: Mild Steelpower Source: Manualmachine Type: Manual , Soil Testing Kit : : Casing: Woodentube Material: Glass , General Balance : : Weighing Capacity: 30Kgaccuracy: ±5G , Foot Sprayer : : Capacity: 6 Litersautomation Grade: Manualusage/Application: Spraying , Salometer : : Salinity Range: 0-00Operating Temperature: 0-55Degree Csalinity Resolution: Temperature Resolution: 55Degree Csalinity Accuracy: 0.%Temperature Accuracy: Degree C , Brix Hydrometer : : Degrees Brix: 0-30 / 30-60 / 60-90 / 0-0 / 0-20 / 20-30 / 30-40 / 40-50 / 50-60 / 60-70 / 70-80 / 80-90Heat Capacity: 20 Degree Caccuracy: 99%Response Time: 0 Secondtemperature: 50 Degree C , Electrically Operated Mixer Cum Grinder : : Blade Material: Stainless Steelspecial Feature: Adjustable Speed Control, Lightweightcontrols Type: Knob , Measuring Tape : : Type: Hard Tapebody Material: Plasticlength: 00 Mblade Material: Copper , Knife Set : : (A) Stainless Steel, Pointed Edge, One Side Sharp (B) Peeling And Pitting Knife (C) Pitting Knife (D) Coring Loop (E) Fruit Puncher (F) Fruit Cutter (G) Pineapple Eye Remover (H) Pineapple Puncher. , Heater : : 500 Watt , Hose Pipe : : Standard - 40 Feet , Vegetable Slicer, Potato Slicer, Pineapple Slicer : : Standard Set , Spade : : Local-Made , Hand Leveller : : Standard , Axe (Local Made) : : Handle Material: Woodenhandle Length: 2.5 Feethead Material: High Carbon Steel , Pruning Secateur : : Material: High Carbon Steel Blade , Watering Can : : Material: Plasticcapacity: 5 Litre , Fruit Tree Picking Pole With Basket : : Locally Available , Sickle : : Local-Made , Pulper : : Stages: Singlevoltage: 220/440Electricity Phase: Three Phasemotor: 5Hpmaterial: Contact Parts Made Of Ss-304Automation Grade: Automatic , Cabinet Dryer : : Weight (Kg): 90Voltage (V): 220Automation Grade: Semi-Automatic , Water Distillation Unit : : Material: Stainless Steelpower: 220/230 Volts Ac Supplygrade: Ss-304 Grade Argon Annual Rate Contract Weldedrubber Tubing Coil: 5 Meters , Wheelbarrow : : Capacity: 0 Kgnumber Of Wheel: 2Material: Plastic , Can Vacuum Testing Gauge : : Measuring Range: -0.--0 Mpa/ -5--0 Psi/ -76--0Cmhgscale Value: 0.005Mpaaccuracy:+/-2.5% (+/-0.0025Mpa)
Contract Date: Feb 27, 2026 Contract Value : 7.40 Lakh
Government Departments No of Bidders 8
West Bengal View Result →
38.
Educational and Research Institute #9661617 AOC
Library Books , Design Of Machine Elements , Bhandari.V.B;4 Ed; Tata Mcgraw Hill ; 2016 , Machine Design ; Sundaramoorthy; Latest; Anuradha Publications; 2003 , Dimensional Metrology; Dotson Connie; 1 Ed ; Thomson Delmar ; 2012 , Handbook Of Dimensional Measurements ; Mark Curtis, 5 Ed; Industrial Press; 2013 , Automation, Production System And Computer Integrated Manufacturing ; Mikell P.Groover; 4Ed; Phi; 2014. , Cad/Cam/Cim ; P.Radhakrishnan;3Ed; New Age Int; 2008 , Material Science And Metallurgy ; O.P.Khanna; Latest; Dhanpat Rai ; 2014 , Engineering Materials And Metallurgy;R.K. Rajput; Latest; S Chand , Material Science & Engineering ;William & Collister; Latest; Wiley; 2014 , Engineering Thermodynamics ;P.K Nag; 6Ed; Tata Mch; 2017 , Engineering Thermodynamics ;Natarajan.E;2Ed; Anuragam ; 2014 , Power Plant Engineering ; P.K Nag ; Latest ;Tata Mcg Hill:2008 , Text Book Of Power Plant Engineering;R.K. Rajput; Latest; S Chand ; 2016 , Engineering Mechanics ;Beer And Johnston; 12Ed; Tata Mcg Hill ; , Manufacturing Engineering And Technology;Kulpakjian;4Ed; Pearson India ; 2013 , Hydraulics And Fluid Mechanics ;Modi P.N & Seth;22Ed;Standard Book House;2019 , Fluid Mechanics Including Hydraulic; Jain A K; Latest; Khana 2014. , Practical Non Destructive Testing ;Baldev Raj Etc; 3 Ed; Alpha Science Int. 2002 , Surveying ;Dr.B.C. Punmia, Ashok K.Jain And Arunk.Jain ; (16Th Ed) Vol. I & Ii ; Lakshmi Publication Pvt. Ltd New Delhi; 2016. , Ground Improvement Techniques ; Dr.P.Purushothamaraj Lakshmi Publications , Ground Improvement Techniques ; P.Kavitha And K.Mohan; R-2021; Magnus Publications , Water Supply And Waste Water Engineering; S.Herald Lessly; Magnus Publication. , Water Supply Engineering (Environmental Engineering Vol I ) ; Khanna Publications. , Waste Water Engineering (Environmental Engineering Vol. Ii); S.K.Garg; Khanna Publishers. , Design Of Reinforced Concrete Structures (Is 456-2000); N.Krishnaraju; 3Rd Ed Cbs Publication And Distributors. , Hydrology And Water Resource Engineering (Irrigation And Water Power Engineering) Dr.B.C.Punmia, (16Th Ed) Lakshmi Publication Pvt Ltd New Delhi 2016 , Structural Dynamics And Earthquake Engineering (Structural Dynamics And Seismic Design) S.R.Damodarasamy, S.Kavitha, Phi Publication Pvt Ltd , “Engineering Mechanics – Statics And Dynamics” ; Vela Murali; Oxford University Press , 2018 , Vector Mechanics For Engineer: Statics And Dynamics ; Beer Ferdinand P, Russel Johnstanjr , David F Mazurek, Philip J Cornwell, Sanjeev Sanghi, 11Th Ed Mcgraw Higher Education , 2017. , Human Value And Ethics ; Research Methodology For Natural Science By Sokmitrabanarjee, Iisc Press, January 2022. , Research Methodology And Ipr Catherine J.Holland , “Inkelletual Property Patents, Trademarks, Copyright Trade Secrets”, Entrepreneur Press, 2007. , “Essentials At Bridge Engineers”, Johnson Victor. D ; 6Th Ed , Oxford And Ibh Publishing Co .New Delhi , 2018. , “Design Of Bridges” Krishnaraju N, 4Thed , Oxford And Ibh Publishing Co.Neew Delhi , 2018. , Construction Material Technology K.Arun, Dr.R.Saravanan, Suchitra Publications. , Concrete Technology - Theory And Practice, Shetty.M.S. Jain A K., S.Chand And Company, Eighth Ed, 2019. , Rehabilitation Of Concrete Structures ,B.Vidivelli,, Standard Publishes Distribution.1St Ed 2009. , Precast Concrete Structures, Alfred Steinle, Hubert Bachmann, Mathias Tillmann, Philip Thrift ., Ernst & Sohn, Berlin, 2019. , Precast Concrete- Materials, Manufacture, Properties And Usage , Lewitt,M., ,Crc Press, 2019. , ‘Estimating And Costing In Civil Engineering’ ,B.N Dutta, Twenty Eighth Revised Ed, , Cbs Publishers & Distributors (P) Ltd, 2020. , ‘Civil Engineering Contracts And Estimates’, B.S.Patil, , 7Th Ed, University Press, 2015. , Structural Analysis,Vol.1,& 2, Bhavikatti, S.S , Vikas Publishing House Pvt.Ltd.New Delhi-4, 2014. , Structural Analysis (Vol. I, Ii, Iii), Dr. R. Vaidyanathan;Dr. P. Perumal, 4Th Ed, Laxmi Publications Pvt. Ltd. 2023. , Theory Of Structures , Punmia.B.C, Ashok Kumar Jain & Arun Kumar Jain, Laxmi Publications, New Delhi, 2004. , “Introduction To Geographic Information Systems”,Kang - Tsung Chang,2Nd Ed, 2011, Mcgraw Hill Publishing. , Fluid Mechanics And Hydraulic Machines, R.K.Bansal,9Ed,Lakxmi Purblication,2010 , Theory Of Machines, S.S. Rattan , 5 Ed, Mcg Hill, 2021 , Manufacturing Technology, P N Rao, 5 Ed, Mcg Hill,2023 , Engineering Mechanics (Short Questions And Answers), Sankar Asubramani A.N,3 Ed, S Chand,2000 , Engineering Thermodynamics, P.K. Nag , 8 Ed, Tata Mcg Hill,2017 , Transport Management, John Duke, 4 Ed, Mch Hill,2010 , Automotive Engines, John B.Heywood, 1 Ed, Mcg Hill,2017 , Engine And Vehicle Management Systems, Eric Chowanietz, 4 Ed, Sae Publication,2017 , Fundamentals Of Management, Stephen A. Robbins , 7 Ed, Pearson, 2016 , Industrial Engineering And Production Management, Martand Telsang, 1 Ed, S Chand, 2018 , Internal Combustion Engines, V. Ganesan, Ed 4, Tata Mcg Hill,2014 , A Text Book Of Machine Design, Khurumai & Gupta, Ed 25, Eurasia Publishing,2020 , Automobile Chassis Design, Dean Averns , 1 Ed, Liffe & Sons ,2009 , Two And Three Wheler, Thruv U Panchal, 1 Ed, Phi India,2015 , Mechatronics, Rk Rajput, Ed 16, Kanna,2017 , Automotive Electrical And Electronics Stystems, A K Babu, 16 Ed, Kanna,2016 , Non Conventional Energy Sources, Rai G D,4 Ed, Khanna,2021 , Basic Electrical And Electronics Engineering ;Kothari Dp And I.J Nagrath ; Second Edition ;Mcgraw Hill Education, 2020 , Basic Electrical And Electronics Engineering; S.K.Bhattacharya ; Second Edition, 2017 ; Pearson Education ; 2017 , A Textbook Book Of Applied Electronics ; Sedha R.S ;2008; S. Chand & Co; 2008 , Dorf’S Introduction To Electric Circuits ; James A .Svoboda, Richard C. Dor; 2018 ; Wiley ; 2018 , A Course In Electrical & Electronic Measurements & Instrumentation ; A.K. Sawhney, Puneet Sawhney ; 2015 ; Dhanpat Rai And Co; , Principles Of Electromagnetics; Mathew N. O. Sadiku; 6Th ,2015; Oxford University Press; 2015 , Engineering Electromagnetics; William H. Hayt And John A. Buck; 2014; Mcgraw Hill Special Indian; 2014 , Electromagnetics With Applications; Kraus And Fleish; 5Th,2010; Mcgraw Hill International Editions ; 2010 , Digital Logic And Computer Design; Morris Mano.M; 3Rd,2005; Prentice Hall Of India; 2005 , Digital Principles And Design; Donald D.Givone; 1St,2003; Tata Mcgraw Hill; 2003 , Digital Fundamentals; Thomas L Floyd; 11Th,2018; Pearson Education Limited; 2018 , Microelectronic Circuits; Sedra And Smith; 7Th,2017; Oxford University Press; 2017 , Electric Machinery; P. S. Bimbhra; 2Nd,2021; Khanna Publishers; 2021 , Basic Concepts In Environmental Management; Mackenthun, K.M; 1998; Lewis Publication; 1998 , Engineering Applications In Sustainable Design And Development ; Bradley. A.S; Adebayo, A.O., Maria; 2015; Cengage Learning; 2015 , Power System Engineering; D.P.Kothari, I.J. Nagarath; 3Rd 2019; Mc Graw-Hill Publishing Company; 2019 , Electrical Power Systems; C.L.Wadhwa; 7Th 2022; New Age International Ltd; 2022 , Electric Power Generation, Transmission And Distribution; S.N. Singh; 2Nd 2008; Prentice Hall Of India Pvt.Ltd; 2008 , Op-Amp & Linear Ics; David A. Bell; 3Rd 2011; Oxford; 2011 , Linear Integrated Circuits; D. Roy Choudhary; 4Th 2018; New Age; 2018 , Op-Amps And Linear Integrated Circuits; Ramakant A. Gayakward; 4Th 2021; Pearson Education; 2021 , Electronic Instrumentation; H.S. Kals; 2010; Tata Mcgraw-Hil; 2010 , Microprocessor Architecture Programming And Application; Ramesh S. Gaonkar; 6Th 2013; Pen Ram International (P)Ltd; 2013 , The 8051 Micro Controller And Embedded Systems; Muhammad Ali Mazidi & Janice Gilli Mazidi; 2Nd 2011; Pearson Education; 2011 , The Pic Micro Controller And Embedded Systems; Muhammad Ali Mazidi & Janice Gilli Mazidi; 2010; Pearson Education; 2010 , Electric Machinery; A.E. Fitzgerald, Charles Kingsley, Stephen. D. Umans, ; 6Th 2017; Mc Graw Hill Publishing Company Ltd; 2017 , Electric Machinery Fundamentals; Stephen J. Chapman; 4Th 2017; Mc Graw Hill Education Pvt.Ltd; 2017 , Electric Machines; D.P. Kothari And I.J. Nagrath; 5Th 2017; Mc Graw Hill Publishing Company Ltd; 2017 , Electrical Machinery; P.S. Bhimbhra; 2Nd 2021; Khanna Publishers; 2021 , Power System Analysis; John J. Grainger, William D. Stevenson, Jr; 2017; Mc Graw Hill Education (India) Private Limited, New Delhi; 2017 , Power System Engineering; Kothari D.P. And Nagrath I.J.; 3Rd, 2019; Tata Mcgraw-Hill Education; 2019 , Power System Analysis; Hadi Saadat; 21St Reprint, 2010; Tata Mcgraw Hill Education Pvt. Ltd., New Delhi; 2010 , Power Electronics: Converters, Applications And Design; Ned Mohan, T.M.Undeland, W.P.Robbins; 3Rd (Reprint), 2009; John Wiley And Sons; 2009 , Power Electronics Circuits, Devices And Applications; Rashid M.H.; 3Rd Edition, 2004; Prentice Hall India, New Delhi; 2004 , Power Electronics ; Cyril. W. Lander ; 3Rd Edition 1993; Mc Graw Hill International; 1993 , Power Electronics; P.S.Bimbhra; Third Edition 2003; Khanna Publishers; 2003 , Elements Of Power Electronics; Philip T.Krein; 2013; Oxford University Press; 2013 , Power Electronics; P.C.Sen; .30Th Reprint, 2008.; Tata Mcgraw-Hill; 2008 , Automatic Control Systems; Benjamin C. Kuo; 7Th, 2010; Phi Learning Private Ltd; 2010 , Control Systems Engineering; Nagarath, I.J. And Gopal, M.; 2010; New Age International Publishers; 2010 , Power Quality Enhancement Using Custom Power Devices; Arindam Ghosh And Gerad Ledwich; First Edition,2002; Kluwer Academic Publishers; 2002 , Electric Power Quality; G.T.Heydt; Second Edition, 2011; Stars In A Circle Publications; 2011 , Power System Harmonics – Fundamentals, Analysis And Filter Design; George J. Wakileh; 2019; Springer – Verlag Berlin Heidelberg, New York; 2019 , Axial Flux Permanent Magnet Brushless Machines; Jacek F. Gieras, Dr. Rong-Jie Wang, Professor Maarten J. Kamper ; 2008; Springer Netherlands; 2008 , Switched Reluctance Motor Drives: Fundamentals To Applications; Bilgin, Berker Emadi, Ali Jiang, James Weisheng; 2019; Crc; 2019 , Permanent Magnet Synchronous And Brushless Dc Motor Drives; .Ramu Krishnan; 2009; Crc Press, Marcel Applications; 2009 , Stepping Motors And Their Microprocessor Controls; T.Kenjo; 2009; Oxford University Press, New Delhi, 2000; 2009 , Brushless Magnet And Reluctance Motor Drives; T.J.E. Miller; 1989; Clarendon Press; 1989 , Switched Reluctance Motor Drives Modeling, Simulation, Analysis, Design, And Applications; R. Krishnan; 2017; Crc Press; 2017 , Arm System On Chip Architecture; Steve Furber; 2Nd, 2015; Addisonn Wesley; 2015 , Arm System Developer’S Guide Designing And Optimizing System Software; Andrew N. Sloss, Dominic Symes, Chris Wright, John Rayfield; 1St, 2004; Elsevier; 2004 , Arm Assembly Language’ Fundamentals And Techniques; William Hohl; 2Nd Edition 2014; Crc Press; 2014 , Switchgear And Protection; Sunil S.Rao; 4Th Edition, 2010; Khanna Publishers; 2010 , Power System Protection And Switchgear; Badri Ram ,B.H. Vishwakarma; 2Nd Edition 2011; New Age International Pvt Ltd Publishers; 2011 , Power System Protection And Switchgear; B.Rabindranath And N.Chander; 2Nd Edition, 2018; New Age International Pvt Ltd Publishers; 2018 , Switch Gear And Protection; Arun Ingole; 2018; Pearson Education; 2018 , Electric Energy Systems Theory – An Introduction; Olle. I. Elgerd; 2Nd Edition, 2017; Mcgraw Hill Education Pvt. Ltd; 2017 , Power Generation, Operation And Control; Allen. J. Wood And Bruce F. Wollen Berg; 3Rd Edition, 2013; John Wiley & Sons, Inc; 2013 , Power System Analysis Operation And Control; Abhijit Chakrabarti And Sunita Halder; 4Th Edition, 2018; Phi Learning Pvt. Ltd; 2018 , Hybrid Energy Systems; Bahman Zohuri; First Edition, 2018; Springer; 2018 , Wind Energy Conversion Systems; S.M Muyeen; First Edition, 2012; Springer; 2012 , Emerging Power Converters For Renewable Energy And Electric Vehicles; Md. Rabiul Islam,Md. Rakibuzzaman Shah,Mohd Hasan Ali;First Edition, 2021; Crc Press; 2021 , Thyristor Based Facts Controllers For Electrical Transmission Systems; R. Mohan Mathur, Rajiv K.Varma; 2002; Ieee Press And John Wiley & Sons, Inc, 2002 , Understanding Facts-Concepts And Technology Of Flexible Ac Transmission Systems; Narain G.Hingorani; 2011; Standard Publishers Distributors,Delhi-110006,2011; 2011 , High Voltage Engineering; M.S.Naidu And V. Kamaraju; Fifth - 2013; Tata Mcgraw Hill; 2013 , High Voltage Engineering Fundamentals; E. Kuffel And W.S. Zaengl, J.Kuffel; Second - 2005; Newnes, Elsevier; 2005 , High Voltage Engineering; C.L. Wadhwa; Fourth - 2020; New Age International Publishers; 2020 , The Nonreligious: Understanding Secular People And Societies; Luke W. Galen; 2016; Oxford University Press; 2016 , Secularism: A Dictionary Of Atheism, Bullivant, Stephen; Lee, Lois; 2016; Oxford University Press; 2016 , The Oxford Handbook Of Secularism; John R. Shook; 2017; Oxford University Press; 2017 , The Civic Culture: Political Attitudes And Democracy In Five Nations; Gabriel A. Almond And Sidney Verba; 1963; Princeton University Press; 1963 , Research Methodology For Natural Sciences; Soumitro Banerjee; 2022; Iisc Press; 2022 , Smart Grids Advanced Technologies And Solutions; Stuart Borlase; Second Edition,2018; Crc; 2018 , Smart Grid: Technology And Applications; Janaka Ekanayake, Nick Jenkins, Kithsiriliyanage, Jianzhong Wu, Akihiko Yokoyama; 2012; John Wiley; 2012 , Smart Grid Fundamentals Of Design And Analysis; James Momoh; 2012; Ieee Press 2012; 2012 , Fundamentals And Applications Of Renewable Energy; Mehmet Kanoglu, Yunus A. Cengel, John M. Cimbala, Cgraw Hill; First Edition (10 December 2020); Cgraw Hill; 2020 , Renewable Energy Sources And Emerging Technologies; Kothari; 2Nd Edition (1 January 2011); Prentice Hall India Learning Private Limited; 2011 , Data Warehousing, Data Mining & Olap By Alex Berson And Stephen J. Smith, Tata Mcgraw – Hill Edition , The Data Warehouse Toolkit: The Complete Guide To Dimensional Modelling By Ralph Kimball, Edition 3, John Wiley & Sons , Block Chain Basics By Daniel Drescher, Edition 1, Apress , Solidity Programming Essentials: A Beginner’S Guide To Build Smart Contracts For Ethereum And Block Chain By Ritesh Modi , , Mastering Block Chain: Deeper Insights Into Decentralization, Cryptography, Bit Coin, And Popular Block Chain Frameworks By Bashir And Imran , The Nonreligious: Understanding Secular People And Societies By Luke W. Galen 2016 Oxford University Press , Secularism: A Dictionary Of Atheism By Bullivant, Stephen; Lee, Lois 2016 Oxford University Press , The Oxford Handbook Of Secularism By John R. Shook 2017 Oxford University Press , Research Methodology For Natural Sciences By Soumitro Banerjee January 2022 Iisc Press , The Civic Culture: Political Attitudes And Democracy In Five Nations By Gabriel A. Almond And Sidney Verba, Princeton University Press , Devops: A Software Architect‘S Perspective By Len Bass, Ingo Weber And Liming Zhu, Pearson Education , Learning Robotic Process Automation: Create Software Robots And Automate Business Processes With The Leading Rpa Tool– Uipath, By Alok Mani Tripathi, Packt Publishin , Operating System Concepts By Abraham Silberschatz, Peter Baer Galvin And Greg Gagne, 10Th Edition, John Wiley And Sons Inc , Distributed Systems: Principles And Paradigms By Tanenbaum A S, Van Steen M, Pearson Education , Robotic Process Automation: Guide To Building Software Robots,Automate Repetitive Tasks & Become An Rpa Consultant By Richard Murdoch, Amazon Asia-Pacific Holdings Private Limited , Digital Design : With An Introduction To The Verilog Hdl, Vhdl, And System Verilog;M. Morris Mano, Michael D. Ciletti;6Th ; Pearson Education, 2018 , Computer Organization And Design, The Hardware/Software Interface; David A. Patterson, John L. Hennessy;6Th;Morgan Kaufmann/Elsevier, 2020 , Introducing Data Science; David Cielen, Arno D. B. Meysman, And Mohamed Ali. Manning Publications, 2016 , Statistics: Robert S. Witte And John S. Witte11 Edition Willey2017 , Python Data Science Hand Book; Jake Vander Plas; ;O’Reilly, 2016 , Data Structures And Algorithm Analysis In C Mark Allen Weiss 2Nd Ed Ed,Pearson 2005 , Introduction To Data Structure In C; Kamthane1 Ed; Pearson 2007 , Java: The Complete Reference; Herbert Schildt;11Th;Mcgraw Hill Education,2019 , Introducing Java Fx 8 Programming; Herbert Schildt;1St;Mcgraw Hill Education,2015 , Introduction To Automata Theory, Languages And Computations; Hopcroft Je Motwani R & Ullman Jd 3Ed; Pearson 2008 , Introduction To Languages And The Theory Of Computation; John C Martin;4Th;Tata Mcgraw Hill, 2011. , Artificial Intelligence – A Modern Approach; Stuart Russell And Peter Norvig;4Th;Pearson Education, 2021. , Introduction To Machine Learning; Ethem Alpaydin;4Th; Mit Press,2020 , Machine Learning; Dr.S.Sridhar, Dr.M.Vijayalakshmi, 1Ed,Oxford University Press, 2021 , Database System Concepts : Abraham Silberschatz, Henery F Korth S.Sudharshan Mchill 2020 , Fundamentals Of Database System : Ramez Elmarsri Shamkant B Navathe 7Th Ed, Pearson, 2017 , Introduction To Algorithms;Thomas H. Cormen, Charles E. Leiserson, Ronald L. Rivest And Clifford Stein;3Rd;Prentice Hall Of India, 2009 , Computer Algorithms/C++;Ellis Horowitz, Sartaj Sahni, Sanguthevar Rajasekaran;2Nd;Orient Blackswan2019 , Operating System Concepts,Ll; Abraham Silberschatz, Peter Baer Galvin And Greg Gagne;10Th;John Wiley And Sons Inc., 2018 , Modern Operating Systems; Andrew S Tanenbaum;5Th;Pearson,2022 , ‘Handbook Of Environmental Laws, Rules, Guidelines, Compliances And Standards’, Vol. I And Ii;R.K. Trivedi;38Th;Enviro Media,2010 , Environmental Encyclopaedia; Cunningham, W.P. Cooper, T.H. Gorhani; ;Jaico Publ., House, Mumbai, 2001 , Computer Networking, A Top-Down Approach Featuring The Internet; James F. Kurose, Keith W. Ross;8Th;Pearson Education, 2021 , Data Communications And Networking With Tcp/Ip Protocol Suite; Behrouz A. Forouzan;6Th; Tmh, 2022 , Cyber Security: Understanding Cyber Crimes, Computer Forensics And Legal Perspectives; Nina Godbole, Sunit Belapure;1Th;Wiley India, 2011. , Distributed Computing: Principles, Algorithms And Systems; Kshemkalyani Ajay D, Mukesh Singhal; ;Cambridge Press, 2011. , Advanced Concepts In Operating Systems; Mukesh Singhal, Niranjan G Shivaratri; ;Mcgraw Hill Publishers, 1994 , Hadoop Operations;Eric Sammer; ;O’Reilley, 2012. , Nosql Distilled;Sadalage, Pramod J; , Kamthane, Introduction To Data Structures In C, 1St Ed ,Pearson Education,2007. , Thomas H. Cormen, Charles E. Leiserson, Ronald L.Rivest, Clifford Stein, Introduction To Algorithms, 4Th Ed , Mcgraw Hill, 2022. , Oppenheim, Willsky And Hamid, “Signals And Systems”, 2Nd Ed , Pearson Education, New Delhi, 2015.(Units I - V) , Simon Haykin,Barry Van Veen,“Signals And Systems”,2Nd Ed ,Wiley, 2002 , B.P.Lathi,“Principles Of Linear Systems And Signals”,2Nd Ed ,Oxford, 2009. , M. J. Roberts, “Signals And Systems Analysis Using Transform Methods And Matlab”, Mcgraw- Hill Education, 2018. , John Alan Stuller, “An Introduction To Signals And Systems”,Thomson, 2007. , Robert L.Boylestad And Louis Nasheresky,“Electronic Devices And Circuit Theory”, 10Th Ed , Pearson Education / Phi, 2008. , Adel .S. Sedra, Kenneth C. Smith, Micro Electronic Circuits, Oup, 7Th Ed , 2014. , Donald.A.Neamen,Electronic Circuit Analysis And Design, Tata Mcgraw Hill, 3Rd Ed , 2010. , D.Schilling And C.Belove, Electronic Circuits, Mcgraw Hill, 3Rd Ed , 1989 , Muhammad H.Rashid,Power Electronics, Pearson Education/Phi, 2004 , M.Gopal, “Control System – Principles And Design”, Tata Mcgraw Hill, 4Th Ed , 2012 , J.Nagrath And M.Gopal, “Control System Engineering”, New Age International Publishers, 5Th Ed , 2007. , K.Ogata, “Modern Control Engineering”, Phi, 5Th Ed , 2012. , S.K.Bhattacharya, “Control System Engineering”, Pearson, 3Rd Ed , 2013. , Benjamin. C.Kuo, “Automatic Control Systems”, Prentice Hall Of India, 7Th Ed , 1995 , William I. Fletcher, An Engineering Approach To Digital Design, Prentice-Hall Of India,1980. , Charles H.Roth,Jr, ‘Fundamentals Of Logic Design’, Jaico Books, 4Th Ed , 2002. , Floyd T.L., Digital Fundamentals, Charles E. Merril Publishing Company, 1982. , John.F.Wakerly, Digital Design Principles And Practices, Pearson Education, 4Th Ed., , D.K. Cheng, Field And Wave Electromagnetics, 2Nd Ed., Pearson (India), 2002 2. M.N.O.Sadiku And S.V. Kulkarni, Principles Of Electromagnetics, 6Th Ed., Oxford(Asian Ed ), 2015 , Edward C.Jordan & Keith G.Balmain, Electromagnetic Waves And Radiating Systems, 2Nd Ed , Prentice-Hall Electrical Engineering Series, 2012. , W.H.Hayt And J.A.Buck, Engineering Electromagnetics, 7Th Ed. ,Mcgraw-Hill(India), 2006. , B.M. Notaros, Electromagnetics, Pearson: New Jersey, 2011 , William Stallings, Cryptography And Network Security, 7Th Ed , Pearson Education, 2017(Unit- Iv) , Bhunia Swarup, Hardware Security– A Hands On Approach, Morgan Kaufmann, First Ed , 2018.(Unit – V). , James.F.Kurose And Keith.W.Ross, Computer Networking – A Top – Down Approach, 6Th Ed , Pearson, 2017. , Doughlas .E.Comer, Computer Networks And Internets With Internet Applications, 4Th Ed , Pearson Education, 2008. , D.Roy Choudhry, Shailjain, “Linear Integrated Circuits”, New Age International Pvt.Ltd., 2018, 5Th Ed . (Unit I - V) , Sergio Franco, “Design With Operational Amplifiers And Analog Integrated Circuits”, 4Th Ed , Tata Mc Graw-Hill, 2016 (Unit I – V) , Ramakant A. Gayakwad, “Op-Amp And Linear Ics”, 4Th Ed , Prentice Hall / Pearson Education, 2015. , Robert F.Coughlin,Frederick F.Driscoll, “Operational Amplifiers And Linear Integrated Circuits”, 6Th Ed , Phi, 2001. , S.Salivahanan& V.S. Kanchana Bhaskaran, “Linear Integrated Circuits”, Tmh, 2Nd Ed , 4Th Reprint, 2016 , John G.Proakis And Dimitris G. Manolakis, Digital Signal Processing – Principles, Algorithms And Applications, 4Th Ed , Pearson Education / Prentice Hall, 2007. , V.Oppenheim ,R.W.Schafer And J.R.Buck,? Discrete-Time Signal Processing, 8Th Indian Reprint, Pearson, 2004. , Emmanuel C. Ifeachor & Barrie. W. Jervis, “Digital Signal Processing”, 2Nd Ed, Pearson Education / Prentice Hall, 2002. , Sanjit K.Mitra, “Digital Signal Processing – A Computer Based Approach”, Tata Mcgraw Hill, 2007. , Andreas Antoniou, “Digital Signal Processing”, Tatamcgrawhill, 2006. , Simon Haykins,”Communication Systems”,Wiley, 5Th Ed ,2009.(Uniti-V) , B.P.Lathi, “Modern Digital And Analog Communication Systems”, 4Th Ed , Oup, 2011. , Wayner Tomasi, Electronic Communication System, 5Th Ed , Pearson Education,2008. , D.Roody, J.Coolen, Electronic Communications, 4Th Ed Phi 2006 , B.Sklar, “Digital Communications Fundamentals And Applications”, 2Nd Ed Pearson Education 2007 , Hp Hsu, Schaum Outline Series- “Analog And Digital Communications” Tmh 2006 , Couch.L., Modern Communication Systems, Pearson,2001 , Gilbert M.Masters, ‘Introduction To Environmental Engineering And Science’, 2Nd Ed , Pearson Education, 2004. , Allen, D. T. And Shonnard, D. R., Sustainability Engineering: Concepts, Design And Case Studies, Prentice Hall. , Bradley.A.S;Adebayo,A.O., Maria, P. Engineering Applications In Sustainable Design And Development, Cengage Learning. , Environment Impact Assessment Guidelines, Notification Of Government Of India, 2006. , Cunningham,W.P.Cooper,T.H.Gorhani, ‘Environmental Encyclopaedia’, Jaico Publ., House, Mumbai, 2001. , Dharmendra S.Sengar, ‘Environmental Law’, Prentice Hall Of India Pvt. Ltd, New Delhi, 2007. , Rajagopalan, R,‘Environmental Studies-From Crisisto Cure’, Oup, 3Rd Ed , 2015. , Erach Bharucha, “Text Book Of Environmental Studies For Undergraduate Courses” Orient Blackswanpvt.Ltd.201 , Kaveh Pahlavan, “Principles Of Wireless Networks”, Phi , 2008 , Vijay K.Garg, “Wireless Network Evolution - 2G & 3G”. Prentice Hall, 2008. , Clint Smith,P.E,Dannel Collins,“3G Wireless Networks” Tata Mcgraw-Hill, 2Nd Ed , 2011. , Sassan Ahmadi,“Lte-Advanced– A Practical Systems Approach To Understanding The Gpp Lte Releases 10 And 11 Radio Access Technologies”, Elsevier, 2014. , Jonathan Rodriguez,Fundamentals Of 5G Mobile Networks, John Wiley, 2015. , Ekram Hossain, Dong In Kim, Vijayk.Bhargava, “Cooperative Cellular Wireless Networks”,Cambridge University Press, 2011. , Ekram Hossain, Vijay K.Bhargava (Editor), Gerhard P.Fettweis(Editor), “Green Radio Communication Networks”, Cambridge University Press, 2012. , F.Richard Yu,Yu,Zhang And Victor C.M.Leung“ Green Communications And Networking”, Crc Press, 2012. , Ramjee Prasad And Shingo Ohmori, Dina Simunic, “Towards Green Ict”, River Publishers,2010 , Jinsong Wu, Sundeep Rangan And Honggang Zhang, “Green Communications: Theoretical Fundamentals, Algorithms And Applications”, Crc Press, 2012 , Jan D Rabaey, Anantha Chandrakasan, “Digital Integrated Circuits: A Design Perspective”, Phi, 2016.(Units Ii, Iii And Iv). , Neil He Weste , Kamran Eshranghian, “Principles Of Cmos Vlsi Design: A System Perspective,”Addison Wesley, 2009.(Units- I, Iv). , Michael J Smith,” Application Specific Integrated Circuits, Addison Wesley, (Unit-V) , Samir Palnitkar,”Verilog Hdl: A Guide To Digital Design And Synthesis”, 2Nd Ed, Pearson Education,2003.(Unit - V) , Parag K.Lala, ”Digital Circuit Testing And Testability”, Academic Press, 1997, (Unit-V) , D.A.Hodges And H.G.Jackson, Analysis And Design Of Digital Integrated Circuits, International Student Ed , Mcgraw Hill 1983 , P.Rashinkar,Paterson And L.Singh, System-On-A-Chip Verification-Methodology And Techniques, Kluwer Academic Publishers,2001 , Samiha Mourad And Yervant Zorian, “Principles Of Testing Electronic Systems”, Wiley2000 , M.Bushnell Andv.D.Agarwal, Essentials Of Electronictesting For Digital, Memory And Mixed-Signal Vlsi Circuits, Kluwer Academic Publishers,2000 , Reinhold Ludwig And Powel Bretchko, “Rf Circuit Design” – Theory Andapplications”, Pearson Education Asia, First Ed , 2001. , D. K. Misra, “Radio Frequency And Microwave Communication Circuits”- Analysis Anddesign, John Wiley & Sons, 2004. , Richard Chi-Hsili-,“Rf Circuit Design” –A John Wiley & Sons, Inc , Publications , W.Alan Davis, Krishna Agarwal,“ Radio Frequency Circuit Design” ,Johnwilly & Sons,2001100) , Mathew M. Radmanesh, “Radio Frequency &Microwave Electronics”, Pearson Education Asia, 2Nd Ed , 2002 (Unit – V) , John D Ryder, “Networks Lines And Fields”, Prentice Hall Of India, New Delhi, 2005. (Unit I– Iv) , Annapurna Das, Sisir K. Das, “Microwave Engineering”, Mcgraw Hill Education (India) Private Limited, 3Rd Ed ,2000.(Unit – V) , Wireless Communication – Andrea Goldsmith, Cambridge University Press,2011 , Van Nee,R. And Ramji Prasad,-Ofd Mforwireless Multimedia Communications, Artech House, 2000. , David Tse And Pramod Viswanath,- Fundamentals Of Wireless Communication, Cambridge University Press, 2005. , Upena Dalal, Wireless Communication”, Oup, 2009. , Andreas.F.Molisch,?Wireless Communications”, John Wiley–India, 2006. , Edward C. Jordan & Keith G. Balmain,Electromagnetic Waves And Radiating Systems,2Nd Ed , Prentice-Hall Electrical Engineering Series, 2012. , W.H.Hayt And J.A.Buck, Engineering Electromagnetics,7Th Ed., Mcgraw - Hill(India), 2006 , B.M.Notaros, Electromagnetics, Pearson: New Jersey, 2011 , D.K.Cheng, Field And Wave Electromagnetics ,2Nd Ed., Pearson(India), 2002 , M.N.O.Sadikuand S.V.Kulkarni, Principles Of Electromagnetics, 6Th Ed.,O Xford (Asian Ed ),2015 , Holger Karl ,Andreas Willig, “Protocol And Architecture For Wireless Sensor Networks”, John Wiley Publication, 2006. , Anna Forster, “Introduction To Wireless Sensor Networks”, Wiley,2017. , Zach Shel By Sensinode And Carsten Bormann, “6Lowpan: The Wireless Embedded , Hess W., “Introduction To Space Science”, Gordon & Breach Science Pub; Revised Ed.,1968. , Krishnaswami K.S.,“Astrophysics: Amodern Perspective”, New Age International, 2006. , Arnab Rai Choudhuri, “Astrophysics For Physicists”, Cambridge University Press, New York, 2010. , Krishnaswamik.S., “Understanding Cosmic Panorama”, New Age International, 2008. , Dan W.Patterson, “Introduction To Ai And Es”, Pearson Education,2007 , Deepak Khemani, Artificial Intelligence, Tata Mc Graw Hill 2013 , Christopher M. Bishop,“Pattern Recognition And Machine Learning”, Springer, 2006. , Tom Mitchell,“Machine Learning”, Mcgraw Hill, 3Rd Ed ,1997. , Mehryar Mohri, A Fshin Rostamizadeh, Ameet Talwalkar, “Foundations Of Machine Learning”, Mit Press, 2012. , Ethem Alpaydin, “Introduction To Machine Learning”, Mit Press, 4Th Ed , 2020. , Mohammed Ali Mazidi, Janice Gillispiemazidi, Rolind.Mckinlay, The 8051 Microcontroller And Embedded Systems Using Assembly And C, 2Nd Ed , Pearson Education, 2008.(Unit -I) , Marilyn Wolf, Computers As Components – Principles Of Embedded Computing System Design, 3Rd Ed , Morgan Kaufmann, 2012.(Unit – Ii,Iii) , Arshdeep Bahga,Vijay Madisetti, Internet–Of-Things– A Handson Approach, Universities Press, 2015.(Unit – Iv,V) , Mayur Ramgir,Internet–Of– Things, Architecture, Implementation And Security, First Ed , Pearson Education, 2020. , Lyla B.Das, Embedded Systems: Anintegrated Approach, Pearson Education 2013. , Jane.W.S.Liu,Real–Time Systems, Pearson Education,2003. , Trit.Ha,“Digital Satellite Communications”,2Nd Ed , Mcgrawhill Education, 2017. , Wilbur L.Pritchard, Hendri G.Suyderhoud, Robert A.Nelson, “Satellite Communications Systems Engineering” 2Nd Ed , Prentice Hall Pearson, 2013. , M.Richharia, “Satellite Communication Systems-Design Principles”, Macmillan, 1999. , Brian Ackroyd, “World Satellite Communication And Earth Station Design”,Bsp Professional Books, 1990. , Dennis Roddy, “Satellite Communication”, 4Thed , Mcgraw Hill International,2017. , Bruce R. Elbert, “The Satellite Communication Applications”, Hand Book, Artech House Bostan London, 2003. , Timothy Pratt, Charles, W.Bostain,Jeremy E.Allnutt, Satellite Communication” ,3Rd Ed , Wiley Publications,2021. , Harold Koontzand Heinz Weihrich “Essentials Of Management” Tata Mcgraw Hill,1998. , Stephen P. Robbins And Mary Coulter, “Management”, Prentice Hall(India) Pvt. Ltd., 10Th Ed , 2009. , Robert Kreitner And Mamata Mohapatra, “Management”, Biztantra, 2008. , Tripathy Pc And Reddy Pn, “Principles Of Management”, Tata Mcgraw Hill, 1999. , Doebelins Measurement Systems: 7Th Ed (Sie),Ernest O. Doebelin Dhanesh N.Manik Mcgraw Hill Publishers, 2019. , Robert Brandy, “Automotive Electronics And Computer System”, Prentice Hall, 2001 , William Kimberley,” Bosch Automotive Handbook”, 6Th Ed , Robert Bosch Gmbh, 2004. , Bosch Automotive Electrics And Automotive Electronics Systems And Components, Networking And Hybrid Drive,5Th Ed, 2007, Isbnno :978-3-658-01783-5. , James D Halderman,“Automotive Electrical And Electronics”, Prentice Hall, Usa,2013 , Tom Denton, “Automotive Electrical And Electronics Systems,”3Rd Ed , 2004, Sae International. , Patranabis.D,“Sensors And Transducers”,2Nd Ed , Prentice Hall India Ltd,2003 , William Ribbens, Understanding Automotive Electronics - An Engineering Perspective, 7Th Ed , Elsevier Butterworth-Heinemann Publishers, 2012. , Ganesh.S.Hedge,”A Text Book Of Industrial Robotics”, Lakshmi Publications, 2006. , Mikell.P.Groover, “Industrial Robotics – Technology, Programming And Applications” Mcgraw Hill 2Nd Ed 2012. , Fu K.S. Gonalz R.C. And Ice C.S.G.”Robotics Control, Sensing, Vision And Intelligence”, Mcgraw Hill Book Co. 2007. , Yoram Koren ,“Robotics For Engineers”, Mcgraw Hill Book,Co.,2002. , Janakiraman P.A., “Robotics And Image Processing”, Tata Mcgraw Hill 2005. , John.J.Craig, “Introduction To Robotics: Mechanics And Control” 2Nd Ed , 2002. , Jazar, “Theory Of Applied Robotics: Kinematics, Dynamics And Control”, Springer India Reprint, 2010. , The Non Religious: Understanding Secular People And Societies, Luke W.Galen Oup, 2016. , The Civic Culture: Political Attitudes And Democracy In Five Nations By Gabriel A. Almond And Sidney Verba, Princeton University Press, , Research Methodology For Natural Sciences By Soumitro Banerjee, Iisc Press, January 2022. , Gate 2026 : Civil Engineering - Study Guide | 3200+ Mcqs & Ntqs, Msq Question Bank | Includes Gate Solved Papers 2023-2025 | Gate Prep Guide | With Gate Flix Test Series: Gk Publication , Gate-2026: Civil Engineering : Made Easy Publication , Gate Tutor Civil Engineering Exam 2026 | With Solved Papers 2025-23 & 5 Mock Tests By Prashant Dixhit : Arihant Publication , Gate 2026 : Mechanical Engineering - Study Guide | 3750+ Mcqs, Ntqs, Msq Question Bank | Includes Gate Solved Papers 2023-25 : Gk Publication , Gate - 2026 : Mechanical Engineering : Made Easy Publication , Gate Tutor Mechanical Engineering Exam 2026 | With Solved Papers 2025-23 & 5 Mock Tests By Er. Dinesh Nath Goswami : Arihant Publication , Gate 2026 : Electrical Engineering - Study Guide | 3000+ Mcqs, Ntqs, Msq Question Bank | Includes Gate Solved Papers 2023-25 Gk Publication , Gate - 2026 : Electrical Engineering : Made Easy Publication , Gate Tutor Electrical Engineering Exam 2026 | With Solved Paper 2025-23 & 5 Mock Tests By Prashant Bharti, Er. Bhavin Juneja, Gaurav Goel :Arihant Publication , Gate 2026 : Electronics & Communication Engineering - Study Guide | 2800+ Mcqs, Ntqs, Msq Question Bank | Includes Gate Solved Papers 2023-25 Gk Publication , Gate - 2026 : Electronics Engineering : Made Easy , Gate Tutor Electronics & Communication Engineering Exam 2026 | With Solved Papers 2025-23 & 5 Mock Tests By Ankit Goel, Alka Singh :Arihant Publication , Gate 2026 : Computer Science & Information Technology – Study Guide | 3100+ Mcqs & Ntqs | Inside Solved Paper 2023-2025 | Msq Question Bankgk Publication | Gate Prep Guide Gk Publication , Gate - 2026 : Computer Science And Information Technology : Made Easy , Gate Tutor Computer Science & Information Technology Exam 2026 | With Solved Papers 2025-23 & 5 Mock Tests By Shanti Kirupani, Prachi Jain, Amrita Mishra: Arihant Publication , Business And Professional Communication: Keys For Workplace Excellence (5Th Ed.).Miller, K. Q., & Wahl, S. T. , Sage Publications, 2023 , English Language And Communication Skills For Engineers,Kumar, Sanjay & Pushpalatha.Oup,2018 , Communication Skills For Engineers And Scientists (2Nd Ed.),Sharma, S., & Mishra, B.Phi,2024 , English Language Skills For Engineers, Koneru Aruna, Mcgraw Hill,2020 , Communication For Business: A Practical Approach, Taylor, Shirley & Chandra. V.Pearson, 2010 , Listening: B2 (Collins English For Life: Skills),Ian Badger, Et Al., Collins, 2014 , Grammar In Use, Raymond Murphy, Cambridge, 2019 , You Can Win , Life Skills 101: A Practical Guide To Leaving Home And Living On Your Own , Personality Development & Soft Skills (3Rd Impression) , Life Skills For Engineers , Six Thinking Hats , Critical Thinking: What Is It And Why It Counts? , Thinking, Fast And Slow , Developing Management Skills , University Physics With Modern Physics, Young, H. D., & Freedman, R. A., Pearson, 2020. , Engineering Physics, Gaur, R. K., & Gupta, S. L.Dhanpat Rai, 2022 , Elements Of Properties Of Matter. Mathur, D. S., S Chand, 2010. , Introduction To Quantum Mechanics. Griffiths, D. J. Cambridge University Press, 2018 , Laser Fundamentals (2Nd Ed.).Silfvast, W. T.Cambridge University Press, 2008 , Elements Of Properties Of Matter. Mathur, D. S. S Chand, 2008 , Heat, Thermodynamics And Statistical Physics. Brij Lal, & Subramaniyan, N., S Chand, 2018 , Physical Metallurgy: Principles And Practice. Raghavan, V, Phi, 2009 , Materials Science And Engineering. Askeland, D.Brooks/Cole., 2010 , Modern Physics,R.Murugesan, S Chand, 2023 , Textbook Of Dynamics, Sigh, Kaushal Kumarphi,2011 , Quantum Mechanics, Sathay Prakash, 2016 , A Text Book Of Optics,Brij Lal, M N Avadhanulu & N Subrahmanyam, S Chand , 2012 , Calculus: Early Transcendentals, Anton, H., Bivens, I. C., & Davis, S.,Wiley, 2021 , Calculus: An Applied Approach,Ron Larson And David C. Falvo, Cengage, 2013 , Calculus,Stewart, J., Clegg, D., & Watson, S, Early Trans, 2019 , Thomas Calculus,Thomas, G. B., Jr., Weir, M. D., Hass, J., & Heil, C., Early Trans,2018 , Engineering Mathematics Through Applications.,Singh, K, Bloomsbury, 2019 , Higher Engineering Mathematics , Linear Algebra Friedberg, S. H., Insel, A. J., & Spence, L. E., Pearson, 2022 , Linear Algebra And Its Applications With Matlab, Lay, D. C., Lay, S. R., & Mcdonald, J. J., Pearson,2020 , Schaum’S Outline Of Matrix Operations, Bronson, R.Mcgraw Hill, 2011 , Linear Algebra And Its Applications, Strang, G., & Thomson, R., Brooks, 2005 , Schaums Outline Of Linear Algebra, Lipschutz, S., & Lipson, M.Mcgraw,2009 , Advanced Engineering Mathematics, Kreyszig, E. , Wilely, 2018 , Engineering Chemistry (17Th Ed),Jain,P.C., &Jain.M, Dhanbat Rai,2015 , A Text Book Of Engineering Chemistry, Dara,S.S, Chand, 2004 , Basics Of Nano Chemistry, Sachdeva,M.V., Anmol, 2011 , Engineering Chemistry ,Friedrich.Emedtech, 2014 , Engineering Chemistry,Palanna ,O.G,Mcgraw, Hill, 2009 , Emerging Materials For Energy Conversion And Storage,Cheong, K. Y., Impellizzeri, G., & Fraga, M. A. , Elsevier, 2018 , Composite Materials, Sharma, S. C, Naraso,2000 , Design And Manufacture Of Composite Structures, Eckold, G. , Woodhead,1994 , Fundamentals Of Analytical Chemistry.,Skoog, D. A., West, D. M., Holler, F. J., & Crouch, S. R.,Cengage, 2022 , Green Building Materials: A Guide To Product Selection And Specification,Spitzer, W. G., & Simonson, K. ,Wiley, 2011 , ????? ??????, ???????? ?????????,??.??. ??????,????????? ??????? ??????? ?????????? ?????? ????? , ????????????,?????????. ????????,?????? ???????? , ????? – ???? ???????????? ???? ??? ??? ????????,????????? ???? , ??????, ????????? ????????,????????? ???? , Social Life Of Tamils,Dr.K.K.Pillay,Tntb & Esc And Rmrl , Social Life Of The Tamils – The Classical Period, Dr.S.Singaravelu International Institute Of Tamil Studies , Historical Heritage Of The Tamils, Dr.S.V.Subaramanian, Dr.K.D. Thirunavukkarasu, International Institute Of Tamil Studies , The Contributions Of The Tamils To Indian Culture, Dr.M.Valarmathi, International Institute Of Tamil Studies , Keeladi – ‘Sangam City C Ivilization On The Banks Of River Vaigai’,Department Of Archaeology & Tamil Nadu Text Book And Educational Services Corporation, Tamil Nadu , Studies In The History Of India With Special Reference To Tamil Nadu,Dr.K.K.Pillay , Porunai Civilization,Department Of Archaeology & Tamil Nadu Text Book And Educational Services Corporation, Tamil Nadu , Journey Of Civilization Indus To Vaigai,R. Balakrishnan Rmrl
Contract Date: Mar 06, 2026 Contract Value : 10.20 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
40.
Educational and Research Institute #9617219 AOC
Tender For Supplying, Installation, Testing And Commissioning Of Machines & Equipment For Civil Engineering Department At Ttaadc Polytechnic Institute, Khumulwng, West Tripura For The Project Improvement Of Infrastructure In Ttaadc Polytechnic Institute, Khumulwng, West Tripura District Under Higher Education Department Under The Nec Scheme. , Supplying, Installation, Testing And Commissioning Of Machines & Equipment In Civil Engineering Department At Ttaadc Polytechnic Institute, Khumulwng, West Tripura Under The Nec Scheme Improvement Of Infrastructure In Ttaadc Polytechnic Institute, Khumulwng, West Tripura, District Under Higher Education Departmen. , Computerized Universal Testing Machine, 6 Pillar Type, For Conducting Tests On Various Types Of Ferrous And Non-Ferrous Materials; Consisting Of- Loading Unit 600 Kn Capacity, Hydraulic Jaws And Pumping System, Clamping Jaws For Round Specimens, Clamping Jaws For Flat Specimens, Pair Of Compression Plates, For Compression Test, Rollers Of 160 Mm Width And 30 Mm Diameters, For Transverse Test, Bending Table Stopper, Allen Keys, Spanners, Double Shear Test Attachment, Bend Rebend Test Attachment, Electronic Extensometer. , Steel Bar Cutting Machine , Vernier Caliper , Stainless Steel Ruler, 1M Length , Mixer Machineries Concrete Mixer The Counter Balanced Mixing Drum Is Easy To Tilt Two Cubic Feet Mix Capacity. Total Drum Volume Is 3 Cubic Feet.. Suitable For Operation On 220 Volt Single Phase, 50 Cycle, A.C. Supply , Isi Cube Mould Cube Mould, With Base Plate : As Per Is : 516 With Isi Mark Cube Mould, 15 Cm X 15 Cm With Base Plate (Made Of Cast Iron - Isi Mark) , Cement Mortar Cube Mould Cement Mortar Cube Mould Cube Mould, 7.06Cm X 7.06Cm With Base Plate (Made Of Mild Steel) , Vibrating Machine Vibration Machine With Timer : Is : 4031 This Apparatus Is Suitable For Making Cubes Of 70.7 Mm. For Mortar Strength Evaluation. The Mould Is Mounted On A Vibrating Platform With A Frequency Of 12,000±400 Vibrations Per Minute. To The Platform Are Attached Four Matched Springs. The Whole Assembly Is Operated By A Revolving Shaft With An Eccentric Mechanism. The Machine Is Supplied With A Timer, A Switch Mounted On A Steel Panel And A 70.7 Mm. Steel Cube Mould With A Base Plate. , Electronic Balance Capacity 500Gm, 0.01 Gm Accuracy , Electronic Balance Capacity 5Kg, 0.1 Gm Accuracy , Electronic Balance Capacity 20Kg, 0.5 Gm Accuracy , Electronic Balance Capacity 100 Kg, 10G Accuracy , Air Permeability Apparatus (Blaine Type) Isi Certification Mark Is;5516, Fitted In Aluminium Box , Vibrating Table Vibrating Table For Compaction Concrete Cube, Cylinders The Table Deck Size 50 Cm X 50 Cm And Has Stops Along Its Edges To Prevent Moulds From Walking Off The Table During Vibration The Variably Pitch Pulley Arrangement Permits The Frequency To Be Varied Sleeplessly Between A Maximum Of 3600 Vibrations Per Minute A Speed Regulation Handle Is Provided For Increasing Or Decreasing The Frequency. The Vibrating Deck. A Switch Is Provided For Starting The Motor. Operation On 440 Volts, Three Phases, A.C. Supply. Table Top - 50 Cm X 50 Cm , Curing Tank Water Curing Bath With Agitation System Digital Indicator For Temperature * 24- Hour Cycle From Time Of Mixing * Controlled 100° C +/- 2° C. Temp. For Concrete * Controlled 27° C + 2° C Curing Temperature For Grey Cement The Tank Has Been Designed To Accommodate 150 Mm / 70.6 Mm Casted Cubes Up To 12/24 Cubes And Fully Insulated. Complete With A Hinged Lid, Heated, Thermostat And Recirculation Pump. Provision Of Two Removable Racks Allowing Free Circulation Of Water Around Each Cube. The Pump, Drain Valves And Electrical Equipment Are Housed In A Compartment Located At One End Of The Tanks. The Tank Is Heated By An Immersion Heater Under Normal Conditions And Refrigeration System For Grey Cement, The Temperature Is Controlled At 35Deg.C. +/- 2 Deg.C, For About 15 Minutes After Immersion Of The Freshly-Made Specimens. Curing Tank For 12 Moulds Of 150Mm/24 Moulds Of 7.06Mm , Vicat Apparatus Box With Isi Certification Mark, Is:5513, Fitted In Aluminium , Le-Chatelier Mould With Isi Certification Markis:5514, Each , Le-Chatelier Water Bath Controller Size 12X9x12. , Crushing Test Apparatus Based On Is: 9376-1979, Mould And Accessories Which Consists Of A Steel Cylinder Of 150Mm Dia. A Plunger And A Steel Base Plate. , Slump Cone With Tamping Rod Slump Test Apparatus Is : 1199 Is ; 7320 Consists Of Slump Cone Fitted With Handles And Foot Pieces In Position. Base Plate In Octagonal Shape Two Clamps Slide Over The Foot Grips Of A Standard Slump Cone And Hold It Securely While Filling And Roding. A Combination Swivel Carrying Handle. Complete With Graduated Temping Rod 0-60 Cms Long And 16Mm Dia With 0-30 Cms Scale Graduation , Measuring Cylinder(Plastic)(1 Liter) , Measuring Cylinder(Plastic) (500 Ml) , Measuring Cylinder(Plastic) (100 Ml) , Measuring Cylinder (Glass) (1 Liter) , Measuring Cylinder (Glass) (250 Ml) , Le-Chatelier Flask Or Specific Gravity Bottol (Glass) 250 Ml , Glass Funnel , Compaction Factor Apparatus Compaction Factor Apparatus: Is : 5515: Is:1199 Consists Of Two Conical Hoppers And A Cylinder Mounted On A Rigid Metal Frame The Lower Openings Of The Hoppers Are Fitted With Hinged Trap-Doors For Release And During The Fall Of Material. Complete With Trowel Tamping Bar 0-60Cms Long X 16Mm Dia , Sample Tray (Enamel Tray), Size 650X500x50mm , Sample Tray (Enamel Tray), Size 850X600x50mm , Pycnometer/Specific Gravity Bottle (1 Litre) , Cylindrical Mould 150 Mm Dia X 300 Mm High, Cast Iron. , Beam Mould 150 Mm X 150 Mm X 700 Mm Made Of Cast Iron , Beam Mould 100 Mm X 100 Mm X 500 Mm Made Of Cast Iron. , Sample Tray (Enamel Tray), Size 350X300x80mm , Sample Tray (Enamel Tray), Size 250X200x50mm , Sample Tray (Enamel Tray), Size 450X400x50mm , Trowel, Ref Standard Is: 4031, 100 To 150Mm Long Blade With Straight Edge. Weight 210 + 10G , Trowel, Ref Standard Is:5515, 200Mm Long Blade, Weight 210 + 10 G , Spatula, 200Mm Blade With Wooden Handle , Density Basket , Hand Brush , Plastic Water Measuring Cylinder (1 Liter) , Plastic Jar For Measuring Water (500 Ml) , Plastic Jar For Measuring Water (100 Ml) , Asbestos Gloves , Hammer With Wooden Handle , Vernier Caliper , Circular Pan/Tray For Morter Mixing , Digital Compression Testing Machine, As Per Is : 14858-2000, 2000Kn Capacity, Electrically Operated With Three Load Gauges 2000Kn, 1000Kn, 500Kn With Nabl Calibration Certificate With Traceability Certificate. , Standard Penetration Test (Spt) Set Consisting Of Split Spoon Sampler, Drive Weight, Guide Pipe Assembly, Tripod, With Rope 19Mm Dia X 10 Mt Length A Drill Rod, 1M Long Complete With Adaptor, 10 Nos Hand Operated Extractor 38Mm Mm Dia. Specimen , Portable Digital Dissolved Oxygen Meter Display : Lcd Size : 29 Mm X 28 Mm Dual Function Lcd Accuracy : Dissolved Oxygen:+0.1Mg/L, Oxygen In Air:+ 0.1% O ², Temperature:+ 0.8 °C/1.5 °F Resolution : Dissolved Oxygen:0.1Mg/L, Oxygen In Air:0.1% O ² Temperature:0.1 °C. Data Hold: Freeze The Display Reading. Operating Conditions: Temp: 0 To 50 Deg C, Humi: Less Than 80% Rh. Operating Range: Temperature: 0 °C To 50 °C (32 °F To 122 °F) Humidity: Max. 80% Rh. Power Off : Auto Shut Off Saves Battery Life, Or Manual Off By Push Button Power Supply : Dc 1.5V Battery ( Um-4/Aaa ) X 4 Pcs Protection Class: Ip-65: 0 To 50, Ip-67: 0 To 30. Dimensions: 180 X 40 X 40 Mm (7.1 X 1.6 X 1.6 Inch). Weight : 176 G/0.39 Lb Memory Recall: Records Maximum, Minimum And Average Readings With Recall. Measurement & Range : Dissolved Oxygen:0 To 20.0 Mg/L, Oxygen In Air:0 To 100.0 %, Temperature:0.1 , Digital Chlorine Meter •The Meter Measures The Free And Total Chlorine (Cl) In The 0.00 To 3.50 Ppm (Mg/L). The Measuring Method Is An Adaption Of The Usepa Method 330.5 For Waste Water And Standard Method 4500-Ci G For Drinking Water. Range: Free Chlorine (Cl): 0.00 To 3.50 Ppm (Mg/L), Total Chlorine (Cl): 0.00 To 3.50 Ppm (Mg/L). Resolution: 0.001(Mg/L). Light Source: Led, 525 Nm. , Digital Tds Meter Using Latest Microcontroller, Auto Ranging (5 Ranges From 200Ppm To 1000Ppt), Temperature Compensation, Auto Cell Constant Measurement, Touch Keys Along With Tds Cell. (Table Model) , Vertical Double Water Distillation Apparatus Temperature 400 Degree Celcius, Color : Transparent, Frequency: 50 Hz, Display: Manual, Weight 10 Kg, Voltage 220Volt, Capacity 5000 Ml With Two Glass Flask With Embedded Heater In Spiral Type Glass Coil Internally At The Bottom, Double Wall Condenser, Level Cup, Delivery Tube, Metal Stand , Clamp, Boss Head, With Automatic Cutoff Device Etc. As Required , Biological Oxygen Demand (Bod Incubator) Temperature Range From 5 °C To 50 °C. Inner Chamber Made Of Stainless Steel, Temperature Controlled And Indicated By Automatic Solid State Electronic Digital Temperature, Controller Cum Indicator. Outer Body Made Of Thick Gauge M.S. Sheet And Inner Chamber Made Of Stainless Steel. Both The Wall Gapis Highly Insulated With Glass Wool. Door Is Also Double Walled And Insulated With Glass Wool Hanged With Heavy Hinges And Fitted With Rubber Magnetic Gasket. An Inner Glass Door Is Provided For Viewing The Samples On While On Test. A Finned Type Low Wattage Heater Is Provided For Raising Temperature Up To 50°C. A Sealed Type Thermostatically Sealed Compressor Filled With Free On Gas And Fitted With All Accessories Viz. Condenser Capacitor Etc. Are Provided At The Bottom Of The Chamber. Copper Cooling Coils Are Provided With The Chamber For Easy And Uniform Refrigeration Throughout The Working Chamber And Capable To Come Down The Temperature At 5 Deg.C From The Ambient Temperature. A Turbo Type Blower A Fitted With Suitable Electric Motor Are Provided Inside The Working Chamber To Circulate The Hot And Cold Air For Uniform Temperature At Any Desired Temperature. Temperature Is Controlled By A Pid Controller Relay With An Accuracy Of +/- 1C Or 0.5C Supplied Complete With Neon Indicating Lamps, Main Cord, Switch, Hot And Cold Switches, Supplied With Perforated Aluminium Shelves Operated On 220/230 Volt, Single Phase, And 50 Hz. Ac Mains. Capacity: 6 Cubic Ft. , Chemical Oxygen Demand (Cod Incubator It Is Solid Block Heated Unit With Provision For Samples To Be Digested At A Time In 38Mm Dia. Reaction Vessels With 20Ml Sample Size Of Heat At Temp. 150 °C Controlled By Digital Temp. Indicator Cum Controller. It Has Provision For 6 Samples And Is Supplied With 6 Nos. Glass Reaction Vessels And 6 Nos. Air Condensers. Fitted With A 2 Hour German Timer (Including 6 Samples Test) - To Be Supplied With All Accessories. , Jar Test Apparatus Using Latest Microcontroller, Highly Accurate Digital Rpm Indicator Which Can Be Varied From 25 To 200 Rpm, Digital Timer From 1 To 99 Minutes With Alert Sound. Two Pre-Set Programs Allow Routine Speed And Time Parameters To Be Input And Then Selected By Simply Pressing One Button. Parameters Stored In The Battery Backup Memory. , Ph Meter Type: Digital, Ph Range: 0 To 14, Resolution: 0.01Ph, Compensation: 0 To 80 Degree C , Bod Bottel, Capacity 300 Ml , Modified Proctor Apparatus As Per Is:10074:1982 & 2720 (Part Viii), Specification, Made Of Mild Steel Dia: 150Mm, Height 127.3 Mm, Volume: 2250 Cc, Complete With Base Plate And Collar , Rammers, Weight 4.89 Kg Controlled Drop 410 Mm , Maxwell Reciprocal Theorem Apparatus Maxwell Reciprocal Theorem Apparatus Apparatus Consist Of A Mild Steel Beam 100Cm Long And 1.25Cm X 4Mm In Cross Section With Graduations At Every 10Cm Along The Length. It Should Be Supported On Two Knife Edge Supports 70Cm Apart With A 30Cm Overhang On One Side. Reciprocal Theorem Can Be Verified By Direct Measurements Of The Deflections Of Various Points With The Help Of A Dial Gauge Due To A Load Placed At The Reciprocal Points. A Dial Gauge With 25Mm Travel (With A Magnetic Base) Should Be Supplied With The Apparatus. Apparatus To Be Supplied Should Be Complete With A Supporting Stand And A Set Of Weights. , Two Hinged Arch Apparatus Apparatus Has A Span Of 100Cm And Rise 25Cm. Both Ends Should Have Hinge But One Of The Ends Should Also Be Free To Move Longitudinally. A Lever Arrangement Fitted At This End For The Application Of Known Horizontal Inward Force For Measuring The Horizontal Thrust. Along The Horizontal Span Of The Arch Various Points Are Marked At Equidistant For The Application Of Load. This Being A Statically Indeterminate Structure Of The First Degree. A Dial Gauge With 25Mm Travel (With Magnetic Base) Is To Be Supplied With The Apparatus. Mild Steel Apparatus Complete With A Supporting Stand And A Set Of Weights. , Pin Jointed Truss Apparatus Experimental And Analytical Study Of 1 3 Bar Pin Jointed Truss Apparatus Consists Of Three Suspension Members (Spring Balances) Of Different Stiffness Which Are Jointed At A Point To Form The Redundant Joint. The Upper End Of The Suspension Members Being Tied In A Position To A Vertical Wooden Board. Arrangement Is Provided On A Paper And Also Elongations And Forces In The Suspension Members. , Unsymmetrical Bending Apparatus Apparatus Consist Of An Angle Of Size 1 X 1 X 1/8 Or In Equivalent Metric Units Of Length 80Cm Is Tied As A Cantilever Beam. The Beam Is Fixed At One End Such That The Rotation Of 450 Intervals Can Be Given And Clamped Such That The Principal Axis Of Its Cross-Section May Be Inclined At Any Angle With The Horizontal And Vertical Planes. Also Arrangement Is Provided To Apply Vertical Load At The Free End Of The Cantilever And To Measure Horizontal And Vertical Deflection Of The Free End. A Dial Gauge With Magnetic Base Is Supplied With The Apparatus. , Curved Member Apparatus Apparatus Consists Of A Steel Bar Which Is Used To Make The Different Curved Member Viz. Circle, Semicircle With Straight Arm, A Quadrant Of A Circle And Quadrant Of A Circle With Straight Arm. The Bottom Ends Of The Members Are Fixed To The Base. Under The Application Of Load At Free End, Its Horizontal And Vertical Deflection Can Be Measured With The Help Of Dial Gauges. A Dial Gauge With 25Mm Travel (With A Magnetic Base) Is Supplied With The Apparatus. Apparatus Will Be Supplied Complete With A Supporting Stand And A Set Of Weights , Schimidt Rebound Hammer Test Specification Impact Energy Type N 2.207 Nm (1.63 Ft Lbf) Concrete Compressive 10 To 100 Mpa (1450 To 14500 Psi) Strength Range Types N/L Dimensions Of Housing 55 X 55 X 255Mm (2.16X2.16 X9.84) Weight 570 G Max. Impacts Per Series Memory Capacity Ca. 400 Series Of 10 Impacts (Pc Version Only) Useful Memory Capacity St Version Ca. 200 Series Of 20 Impacts Last 20 Series May Be Reviewed In The Data List Display 17X 71 Pixel, Graphic Battery Life 5000 Impacts Between Charges Charger Connection Usb Type B/C (5V, 100 Ma) Operating Temperature 0 To 50°C (32 To 122°F) Storage Temperature -10 To 70°C (14 To 158°F) Ip Classification Ip54 , Venturi Meter (Bernoullis Theorem Demonstration) Venturi Section Machined From Clear Acrylic, Seven Static Pressure Tappings Plus A Total Head Measurement, Flow Control Valve, Manometer Board With Eight Tubes, Quick-Release Fitting For Easy Connection To Hydraulics Bench. Manometer Range: 0-300 Mm, Number Of Manometer Tubes: 8, Throat Diameter: 10.0 Mm, Upstream Diameter: 25.0 Mm, Upstream Taper: 14°, Downstream Taper: 21, Height: 0.60 M, Width: 0.55 M, Depth: 0.25 M. , Orifice Meter Orifice Discharge Accessory Enables Full Analysis Of The Flow Through Seven Different Orifices Over A Range Of Flow Rates. Determining The Construction And Velocity Coefficients, Calculating The Discharge Coefficient Standard Orifice: Sharp-Edged 13Mm Diameter, Max Head: 365Mm, Traverse Mechanism: Lead Screw With Adjusting Nut Calibrated 0.1Mm Per Division, Height: 0.60 M, Width: 0.33 M, Depth: 0.33 M. , Water Hammer Apparatus A Self-Contained Unit Designed To Demonstrate The Phenomena Of Pipe Surge And Water Hammer. Straight Pipes Are Used, Rather Than A Coiled Arrangement, To Reduce Distortion Of The Pressure Wave. Test Pipes: Stainless Steel, 20.2Mm Inside Diameter, Nominally 3M Long, Surge Shaft: Clear Acrylic, 40Mm Inside Diameter, 800Mm High, Head Tank: Pvc, Capacity 45 Litters, Gross Weight: 420 Kg, Volume: 5 M3, Height:1.865 M, Length: 3.575 M, Depth :0.725 M. , Tilting Flume Apparatus (Adjustable Channel) Tilting Flume Apparatus (Adjustable Channel) Specifications The Tilting Flume Apparatus Should Be Approximately 4 Meter Long Open Channel With 200 Mm Width And 300 Mm Depth. Manual Adjustment Of Slope. Pump Capacity: 1 Hp. Designed To Conduct Various Experiments At Various Bed Slopes With Mechanism To Read The Bed Slope. Screw Jack Arrangement Is Provided To Adjust The Bed Slope Of The Channel As Desired. The Flume Has A Perspex Window At Specific Spots Where Structure Such As Weir, Spillway, Or V Notch Will Be Installed To Visualize The Flow Over Models Fixed In Flume. Trolley Mounted Point Gauge For Level Measurement Of Water. Trolley Can Be Traversed For Whole Length Of Flume. The Mechanism Should Be Able To Read Y And Z Coordinates Along With The X-Coordinate. The Flume Is Provided With Gates On Upstream & Downstream Side To Control The Flow. Various Experiments Like Flow In Open Channel, Hydraulic Jump, And Calibration Of Weirs, Notches And Venturi Flume Can Be Conducted. An Orifice Meter With Manometer Is Provided To Determine The Discharge Provided To The Open Channel By The Feeder Pipe. This Is Used For The Calibration Of The Weirs And Notches. The Set Up Should Be Provided With A Pump Of Adequate Capacity For Recalculating The Water Supply. It Should Be Provided With Collecting And Supply Tank. Stop Watch Be Provided For Recording Time And With Lab Manual. Scope Of Experimentations: • To Calibrate The Notches & Weirs. • To Study About Hydraulic Jump. • To Study Flow Through Venturi Flume. To Study Specific Energy Curves , Metacentric Height Apparatus Determining The Centre Of Gravity Of The Pontoon, Determining The Metacentric Height And From This The Position Of The Metacentre For The Pontoon, Varying The Metacentric Height With Angle Of Heel, Max Angle Of Heel: ±13°, Corresponding Linear Dimension: ±90Mm, Height: 0.475 M, Width: 0.35 M, Depth: 0.20 M. , Pitot Tube Apparatus Description: The Designed Pitot Tube Unit The Change In Flow Speed Within A Tube Can Be Determined. The Pitot Static Tube Can Be Moved Across The Whole Cross- Section Of The Tube, And Thus To Measure The Pressure Profile. This Tube Is Connected To Manometers Via Hoses. The Pitot Tube Can Be Moved Across The Cross-Section Of The Pipe In Order To Measure The Dynamic Head Profile. The Position Of The Measuring Tip Relative To The Wall Of The Pipe Can Be Read On A Scale. The Pitot Tube Is Connected To A Pressurized Water Manometer To Measure The Differential Head Across The Pitot Static Tube. The Position Of The Measuring Head Relative To The Bottom Edge Of The Tube Can Be Measured On A Scale. The Water Supply Can Come From The Hydraulics Bench Or From The Basic Hydraulic Feed System. The Pitot Tube Can Be Moved Across The Cross-Section Of The Pipe In Order To Measure The Dynamic Head Profile. Features: •Study Of The Function Of A Pitot Static Tube. •To Use A Pitot Static Tube. •Determination Of Tube Flow Speed Profiles. •Demonstration That The Flow Speed Is Proportional To The Pressure Difference Between The Total Pressure And The Static Pressure. •Error Determination In Flow Measurements Using The Pitot Tube As Measurement Instrument. • Factor Cd Determination In The Pitot Tube. • Operation Of A Pitot Static Tube And Pressurized Water Manometer • Velocity Flow Profile In A Pipe • Demonstration That The Fluid Velocity Is Proportional To The Square Root Of The Head Difference Between The Total Head And The Static Head Specification: • Pitot Static Tube: Head Diameter: 2.5 Mm. • Transparent Pipe: 32 Mm. Internal Diameter • Transparent Pipe: 430-Mm.-Length Approx. • Hose Connections. • Water Manometer, 500 Mm. Length. • Easy And Quick Coupling System • Built-In. Anodized Aluminum Structure And Panel Of Painted Steel. • Dimensions And Weight • L X W X H: 800-X600 X 600 Mm • Weight: 40Kg
Contract Date: Feb 19, 2026 Contract Value : 34.03 Lakh
Local Bodies No of Bidders 4
42.
Civil Aviation #9585490 AOC
Supply, Implementation, Customization, Integration, Testing and Commissioning of Microsoft Dynamics 365 Finance & Operations (D365 F&O) at Cochin International Airport- 1 ONETIME COST 2 Project Implementation cost including development, implementation, integration, training, testing, go live, hyper care support and commissioning 3 Cost for all hardware (excluding POS machines) and software for Development and UAT environment including necessary user licenses 4 1ST YEAR LICENSE COST 5 Dynamics 365 Commerce 6 Dynamics 365 Finance attach 7 Dynamics 365 SCM attach 8 D365 Operations Device D365 9 Team Member 10 Power BI 11 Any additional software/cloud licenses, including but not limited to those for the operating system, database, or data warehousing, required to meet the technical specifications. 12 SUPPORT COST - 1ST YEAR 13 Onsite support cost 14 Remote AMC cost 15 RECURRING COST - 2ND YEAR 16 Dynamics 365 Commerce 17 Dynamics 365 Finance attach 18 Dynamics 365 SCM attach 19 D365 Operations Device D365 20 Team Member 21 Power BI 22 Any additional software/cloud licenses, including but not limited to those for the operating system, database, or data warehousing, required to meet the technical specifications. 23 Onsite support cost 24 Remote AMC cost 25 RECURRING COST - 3RD YEAR 26 Dynamics 365 Commerce 27 Dynamics 365 Finance attach 28 Dynamics 365 SCM attach 29 D365 Operations Device D365 30 Team Member 31 Power BI 32 Any additional software/cloud licenses, including but not limited to those for the operating system, database, or data warehousing, required to meet the technical specifications. 33 Onsite support cost 34 Remote AMC cost 35 RECURRING COST - 4TH YEAR 36 Dynamics 365 Commerce 37 Dynamics 365 Finance attach 38 Dynamics 365 SCM attach 39 D365 Operations Device D365 40 Team Member 41 Power BI 42 Any additional software/cloud licenses, including but not limited to those for the operating system, database, or data warehousing, required to meet the technical specifications. 43 Onsite support cost 44 Remote AMC cost 45 RECURRING COST - 5TH YEAR 46 Dynamics 365 Commerce 47 Dynamics 365 Finance attach 48 Dynamics 365 SCM attach 49 D365 Operations Device D365 50 Team Member 51 Power BI 52 Any additional software/cloud licenses, including but not limited to those for the operating system, database, or data warehousing, required to meet the technical specifications. 53 Onsite support cost 54 Remote AMC cost 55 RECURRING COST - 6TH YEAR 56 Dynamics 365 Commerce 57 Dynamics 365 Finance attach 58 Dynamics 365 SCM attach 59 D365 Operations Device D365 60 Team Member 61 Power BI 62 Any additional software/cloud licenses, including but not limited to those for the operating system, database, or data warehousing, required to meet the technical specifications. 63 Onsite support cost 64 Remote AMC cost 65 RECURRING COST - 7TH YEAR 66 Dynamics 365 Commerce 67 Dynamics 365 Finance attach 68 Dynamics 365 SCM attach 69 D365 Operations Device D365 70 Team Member 71 Power BI 72 Any additional software/cloud licenses, including but not limited to those for the operating system, database, or data warehousing, required to meet the technical specifications. 73 Onsite support cost 74 Remote AMC cost
Contract Date: Feb 17, 2026 Contract Value : 23.96 Crore
Boards / Undertakings / PSU No of Bidders 3
43.
Defence #9549440 AOC
Bids Are Invited For Eamp 2026 Work Of Ins Mormugao; 1 COOKING RANGE, HOT PLATES 2 Remove hot plates & drip trays and clean them properly 3 Remove hot plates bearers and Mild steel using heat resisting paint. Re-fix hot plates & drip trays on completion of the work and ensure they are fixed properly 4 Remove both side screens and bottom cover of Ovens. Clean inside thoroughly and ensure all elements are fixed properly in their places 5 Clean and check properly Thermostat, bulb and ensure that they are in order 6 Check performance of ranges and undertake necessary repairs 7 MILLING MACHINE 8 Check performance of machine and make necessary repairs and adjustments 9 AUXILIARY MOTORS (Model: Below 10 KW) 10 Decoupling of motor from pump, removal of motor from first connection and lifting of motor from foundation 11 Shafting of motor from ship to firm’s premises 12 Dismantling of motor and submission of material condition assessment report within 2 hrs for establishment of scope of work 13 Replacement of bearings (inclusive of cost of grease, oil/lip seal, nuts & bolts etc) 14 Repairs of bearing holder/bearing cap 15 Dynamic balancing of rotor 16 Repairs of rotor shaft including shaft trueness checks 17 Rewinding of stator (includes cost of winding wire, varnish, lugs, ebonite/Bakelite sheets, thermistor, stator insulation material, fasteners, oil/lip seals, washer joints etc) 18 Repairs of terminal box 19 Repairs of cooling fan 20 Repairs of foundation stool 21 Boxing up and trials of motor at firm workshop 22 Shifting of motor from firm’s premises to ship for fitment 23 Fitment of motor at location and proving of trials onboard with SS and FMU Rep. 24 Alignment and coupling of pump and motor assembly insitu 25 CO2 FF SYSTEM 26 Check weight of each cylinder. If any cylinder shows loss of gas exceeding 10% of its content, it must be removed for recharging. Note:- Alternately use Portable Ultrasonic Level Detectors for undertaking this routine 27 Calibrate all gauges in the system and issue certificates for NABL accredited laboratory 28 Admit LP air into ring main checking the system for leaks. Ensure that all the discharge pipes and nozzles are clear. 29 INHIBITOR SYSTEM 30 Check all QOVs by operating with Pyro. Dismantle and overhaul 50% of QOVs. The whole checks to be completed in two successive refits. 31 Check integrity of the system. Check all joints for tightness. Renew gaskets if required. Pressure test the system after repair. Rectify defects, if any. 32 Examine all fittings and pipes for damage. Refit/repair as necessary 33 Check and ensure proper insulation of special alloy flanges and sleeve joints. Replace insulating bushes and gaskets if necessary 34 Check ohmic resistance of all squib bridges for guaranteed value and serviceable conditions (from 0.6 to 1.2 ohms). Note:- Direct current not to exceed 0.05A when carrying out SR-4 35 Check integrity/ leakages of all stop check valves and refit if require 36 Carry out the following:-(a) Repairs of defective sensors/ pressure relays / gauges.(b) Calibration of all sensors, pressure relays, gauges and DOZOR Control Cards (including SPTA) at shop floor (DOSSRR). Replace the defective ones. 37 Joint Pressure Testing of overhauled QOVs at shop floor. 38 Joint Certification of entire quick spraying line from the check valve to the sprinklers by SS/Maintainer and rep of Refitting Authority 39 Post fitment of all components, carry out Integrated Test of Joint Operation of APZ 028 / KARAT-M / KRAB / Sprinkling systems as per operation Manual, except operation of pyros and inhibitor system. 40 Overhaul defective bottle head assembly valves. Post overhauling, pressure test the bottle along with assembly. 41 PORTABLE SUBMERSIBLE PUMP 42 Capacity trials to be carried out and defects observed to be rectified 43 Check level and condition of oil in seal package. Renew seal package if oil is emulsified. 44 STP/VTS 45 Overhaul of OBD pump including replacement of 01 mechanical seal E6039D-000667 (04 No) 46 Overhaul of OBD motor including rewinding and replacement of bearings (04 No) 47 Overhaul of mixing and draining pump including replacement of 01 mechanical seal EH6039D-000937 (02 No) 48 Overhaul of mixing and draining motor including rewinding and replacement if bearing (02) 49 Overhaul of macerator pump including replacement of 01 mechanical seal EH6039D-001409 (02 No) 50 Overhaul of macerator motor including rewinding and replacement of bearing (02) 51 DR on whirl container 52 Calibration of pressure gauge (10 No) 53 Cleaning of STP pipeline (50 Mtr) 54 Renewal of pipeline and proving of leak test (50 Mtr) 55 Effluent test of STP (02 No) 56 DR on Control pannel 57 Overhaul of valves (10 No) 58 Replacement of float switch EH6039D-000338 (06 No) 59 Replacement of Tie Bolts M10X450/80/80 9520K (10 No) 60 Modification of VSS pipe and to be done at AFT SS WC bathroom, AFT JS WC bathroom, Passageway 13, Passageway 14 including Piping & Fittings 61 SERVICES (Vide HQWNC fax 300/50/9/69 dated 08 Jul 25) 62 Fitment of 50mm vacuum line and removal of 40mm soil line 63 Welding of flanges for fitment of isolating valve in vacuum line 64 Degutting and regutting of SS panel in JS/ SSWC 65 Cutting of main WT section for passing vacuum pipeline 66 Approximately 540 man-days would be required to undertake the modifications 67 SPARES (Vide HQWNC fax 300/50/9/69 dated 08 Jul 25) 68 GI pipe 50mm SCH 40 69 GI pipe 40mm SCH 40 70 GI pipe 12.5mm SCH 40 71 SS 316 Ball Valve 50mm 72 SS 316 Ball Valve 12.5mm 73 GI Flange 50mm 74 GL Elbow 90’50mm 75 GL Elbow 40’50mm 76 GI TEE 50mm 77 GI reducer 50mm*40mm 78 MS Cooler plate 79 GI C Clamp 50mm 80 GI Barrel Nipple 12.5mm 81 Gasket Neoprene 3mm 82 Gasket Neoprane 2mm*50mm 83 SS 316 Nut bolts with SS washer M16*60mm 84 SS 316 Nut bolts with SS washer M16*50mm 85 DOORS NWT 86 Check clips, hinges for looseness, locking arrangement and any other components for wear and damage and undertake necessary repairs 87 Examine condition of rubber gaskets, door structure and kick out panel and undertake necessary repairs 88 APT 89 Providing of APT in presence of User Dept and Ship Staff. Test parameters involve building up 150 mm pressure drop restricted below 13 mm in 10 minutes/ as prescribed in last report. Calibrated U-tube manometers are to be used. Suitable air pressure and air flow rate generation devices to be arranges by the firm for the test. Acceptance Agency. APT will be offered to external agency, Hull inspection and Trials Unit, Mumbai (HITU) for acceptance. 90 Renewal of rubber beading of WT/GT doors 91 Renewal of rubber beading of WT/GT hatches 92 Structural repairs on WT/GT doors and hatches 93 Removal, repairs/ renewal and fitment of SOQC valves 94 Removal, repairs/ renewal and fitment of WT sluice valves-Removal, Overhauling, refitment, including relacing deamaged/ missing valve wheels and flaps opening of removed valves on trunking to be temporarily blanked for APT 95 Overhauling of mushroom heads ventilation flaps-removal, overhauling, refitme including replacing damaged/ missing valve wheels and flaps opening of removed valves on trunking to be temporaily blanked for apt 96 Packing of cable glands and cable conduits – Rectification of all additional defects precluding proving of APT (including air leaks from glands/ joints/ deck conduit, rubbber coaming etc.). Packing and sealing with sealant, araldite and hardener to prove WT integrity 97 Removal, repairs/ renewal and fitment of Rectangular Ventilation Trunkings – Rectification of all additional defects precluding proving of APT. 98 Manufacture of blanks for blanking and seaming of pipes – Rectification of all additional defects precluding APT (Including air leaks from glands/ joints/ deck conduits/ rubber coaming etc.). Blanking and sealing of pipes to prove WT integrity of compartment. 99 Build up weld seam and pitted surface on decks and bulkheads. 100 Removal and fitment of bulkhead, deckhead and ship’s side covering MFMB lagging/ cladding/ panels/ acoustic panels to provide access to bare metal for conduct of APT and identification of leaks. The items removed are to be replaced on clearance. MFMB sheets for lagging to provide by the firm. 101 Renewal of deck plates in way of APT MS 102 INCINERATOR 103 Carry out cleaning of filters in diesel oil pump and diesel oil supply line (Task 14 of Regular Maintenance Procedures of instructional manual for Incinerator OG200 relevant). 104 Carry out the replacement rubber stator on sludge oil dosage pump. (Task 15 of Regular Maintenance Procedures of instructional manual for Incinerator OG200 relevant). 105 Carry out the inspection/ repair of sludge dosage pump rotor for surface smoothness. (Task 16 of Regular Maintenance Procedures of instruction manual for Incinerator OG200 relevant). 106 Carry out greasing of flue gas fan bearing. (Task 17 of Regular Maintenance Procedures of instructional manual for Incinerator OG200 relevant). 107 Visually inspect the thermocoulpe of combustion chamber. (Task 18 of Regular Maintenance Procedures of instructional manual for incinerator OG200 relevant). 108 Carry out the lubrication of sluice bearings. (Task 19 of Regular Maintenance Procedures of instructional manual for Incinerator OG200 relevant). 109 Carry out the lubrication of door hinges. (Task 20 of Regular Maintenance Procedures of instructional manual for incinerator OG200 relevant) 110 Check the door gasket by using chalk on the edges of the door opening. Close the door. Open and check that the door gasket had contact with the edge all the way around the opening. If not adjust the door. (Task 21 of Regular Maintenance Procedures of instructional manual for Incinerator OG200 relevant). 111 Carry out cleaning of inside of inspection/repair hatch with steam or hot water. (Task 22 of Regular Maintenance Procedures of instructional manual for Incinerator OG200 relevant). 112 Carry out the inspection/repair of Paint work for scratches. (Task 8 of Regular Maintenance Procedures of instructional manual for Incinerator OG200 relevant). 113 Check the control and alarm system according to “Test of function and safety devices”. (Task 8 of Regular Maintenance Procedures of instructional manual for Incinerator OG200 relevant). 114 Check all safety devices and calibrate if necessary. (Task 8 of Regular Maintenance Procedures of instructional manual for Incinerator OG200 relevant). 115 Check all valves, pumps and solenoid valves for leakages. Repair if necessary. (Task 8 of Regular Maintenance Procedures of instructional manual for Incinerator OG200 relevant). 116 Replace nozzles for diesel oil burner with new ones. (Task 8 of Regular Maintenance Procedures of instructional manual for Incinerator OG200 relevant). 117 COLD LAGGING 118 Carry out cold lagging on pipelines (1 in-10 in) 119 Carry out cold lagging on flanges (1 in-10 in) 120 Carry out cold lagging on heat exchangers 121 De-gutting of lagging 122 Lagging insulation material 123 SINGLE ARM DAVIT 124 Carry out SPM checks of electric motor. Lubricate/ replace bearings as necessary 125 Open winch gearing and examine for any evidence of excessive wear or defect 126 Dismantle turning out mechanism from the bevel gear box, bottle screw, grub screw and examine the condition of thrust bearings, sleeves, grub screws for sign of corrosion and wear. Repair/ renew as necessary. Fit back and charge with fresh grease. 127 Examine for corrosion, distortion or other defects paying particular attention to inside surface of davit stand. Check whether paint is cracked, blistered, badly adhering, excessively coated or corrosion is evident. Raise specific defect to dockyard for rectification. Area to be cleaned to bare metal, thoroughly dried and re-preserved 128 HELICOPTER INFLIGHT REFUELING SYSTEM (HIFR) 129 Replace all HIFR hoses 130 H2S SENSOR 131 Calibration/ serviceability checks of Fixed H2S gas detection system. 132 Calibration/ repairs of Hand held gas detectors. 133 CCTV 134 Liquidate defects in CCTV cameras 135 DR on controls and monitoring stations 136 Cabling and wiring as required 137 EMERGENCY ESCAPE SCUTTLES & HATCHES 138 SERVICES 139 Check clips, closing mechanism, hinges for looseness, spring mechanism and wedge pieces/ for signs of wear. 140 Examine neoprene/ teflon washers, toroidal sealing rings and rubber sealings. 141 Raise specific defects to dockyard for repairs. 142 Carry out watertight integrity test of all W.T. hatches using Ultrasonic Leak Detector (ULD) device. 143 Identify the leakage through watertight seals with the help of Ultrasonic Leak Detector and raise specific defects to yard for rectification if any. 144 HATCHES 145 Check clips, closing mechanism, hinges for looseness, spring mechanism and wedge pieces/ for signs of wear. Examine neoprene/ teflon washers, torodial sealing rings and rubber sealings. Raise specific defects to dockyard for repairs. 146 Carry out watertight integrity test of all W.T. hatches using Ultrasonic Leak Detector (ULD) device. Identify the leakage through watertight seals with the help of Ultrasonic Leak Detector and raise specific defects to yard for rectification, if any. 147 Check for any damage on metallic rubber coaming and repair if found damage. 148 WINDOWS & MANHOLES 149 MANHOLES 150 Check clips, closing mechanism, hinges for looseness, spring mechanism and wedge pieces/ for signs of wear. Examine neoprene/ teflon washers, torodial sealing rings and rubber sealings. Raise specific defects to dockyard for repairs. 151 Carry out watertight integrity test of all W.T. hatches using Ultrasonic Leak Detector (ULD) device. Identify the leakage through watertight seals with the help of Ultrasonic Leak Detector and raise specific defects to yard for rectification, if any. 152 WINDOWS 153 Check hinge fitting, toughened glass and glass rails for looseness and sign of wear / damage. Raise specific defects to dockyard for repair/ renewal. 154 RAIL LESS HELO TRAVERSE SYSTEM (RLHTS) 155 Undertaking of routine maintenance/ overhauling/ defect rectification of Rail Less Helo Traverse System (RLHTS) 156 Hydraulic winch and wire rope (Port, Stbd & Aft) 157 Hydraulic power pack (Port, Stbd & Aft) 158 Hydraulic pipes and control valves (Port, Stbd & Aft) 159 Control panel and cabling (Common) 160 FWD CENTRIFUGE 1, 2 & 3 161 Check Threads of inlet pipe of oil pairing disc for damage and wear. Renew of required 162 Check flow indicator if clogged 163 Check the reducing valves cones for scratches and play. Renew if required. 164 check the non return valves cones for scratches and play. Renew if required. 165 Dismantle and examine separator bowl assembly thoroughly. Clean all components and check following:-(i) Check disc stack pressure(ii)Check for erosion, corrosion and cracks(iii) Galling of guide surface 166 Renew oil in gear housing. Check the teeth of worm wheel and worm gear. Renew if required. 167 Carry all routines listed in intermediate service 168 Check height position for pairing disc for MAB206 type separators. 169 HORIZONTAL DRIVE(a) Check axial play of coupling disc.(b) Renew bearings of worm wheel shaft. 170 VERTICAL DRIVE(a) Clean and check bowl spindle and name for impact marks.(b) Check radial wobble of bowl spindle.(c) Clean and check buffer and ball bearings housing. Renew if required.(d) Renew ball bearings and top bearings springs. 171 Clean and check break shoe. Renew friction pads/ break plug. 172 Clean and check friction coupling. Renew friction pads and lip seal ring. 173 Dismantle pump assembly. Clean and check bushings, wear gaskets coupling, relief/safety valve and impeller shaft. Renew lipseal ring. 174 Renew frame fit rubber cushions / vibration dampers.
Contract Date: Ref. Documents Contract Value : 3.13 Crore
Government Departments No of Bidders 3
Maharashtra View Result →
44.
Defence #9545191 AOC
Tender For Provision Of Solar Power Plant At Sevoke Mil Station Under Ge Sevoke Road.; 2 Design, procurement, erection, installation, testing and commisioning including connecting to local utility grid; Grid connected solar photovoltaic plant 0.8 MW output peak capacity with net billing arrangement including Solar Photovoltaic Modules,DC Cabling, Module Mounting Structures (suitable for ground mountingwith and including Soil Investigation as per OEM recommendation, RCC foundation framed structure and other connected civil work duly vetted by IIT / NIT), Array Combining Boxes, ACDB, DCDB, Lightining Protection of SPV modules and other accessories, String Inverter as Power Conditioning Unit, Weather Station and Data Monitoring system (SCADA) all as per detailed specifications given in tender documents, latest MNRE/SECI/NISE/IREDA guidelines and directions, meeting the Make in India (DCR), consisting of all requisite accessories (BOS-Balance of system) and including the following main components (NOTE : The work shall be executed directly by OEM only through contractor.) Item Continued as 1.01 to 1.45 3 (A) Photo Voltaic Module: Mono-crystalline Silicon Bifacial Solar Photovoltaic Modules of minimum 550 Wp(module power and number of modules to be selected according to available area), having cell efficiency more than 20% under standard conditions, form fill factor more than 0.76, plant performance ratio > 75%, made of high transmitivity glass front surface and it shall give high encapsulation gain (transmittance above 90% and bending less than 0.3%). The modules shall have the following features :(a) The electrical parameters of SPV modules under standard test condition of irradiance 1000W/sqm, AM 1.5 Spectrum and temp 25 degree Celsius shall be as under : (i) Max Peak Power Pmax : 550 Wp or more (ii) Voltage at Max Power : > 40 V (iii) Current at Pmax :> 10A 4 (iv) Short Circuit Current :> 12A (v) Open Circuit Voltage :> 47 V (vi) Module Efficiency : > 20%(b) Rated output of the modules shall have positive tolerance of 3-5% and no negative tolerance is allowed.(c) It shall perform satisfactorily in RH 85% with temperature up to +85 degree C and should withstand wind of 200 kmph on the surface of panel.(d) PV modules shall be warranted for their output peak watt capacity, and it shall not fall of its initialvalue below 90% in first 10 year end and 80% after the end of 25 years.(e) Each module shall have RFID tag encapsulated with solar cell bearing following details (i) Name of Manufacturer of SPV Module (ii) Name of Manufacturer of Solar Cell 5 (iii) Month and year of Manufacturing (separately for cell and module) (iv) Country of Origin (both cell and module) (v) Peak wattage, Im, Vm and fill factor of the module (vi) Date of year of obtaining IEC PV module qualification certificate including the test lab issuing IEC certificate. (vii) Unique serial no of model no of module (viii) IV curve of module(ix) Other relevant information on traceability of solar cells & modules(f) The temperature coefficient of power for the module shall not be more than 0.50% per degree Celsius.(g) The module must have bypass diode of suitable capacity.(h) PV module must confirm to latest edition of IEC 61215/ IS 14286. In addition the modules must confirm to IEC 61730 Part I and II for construction and testing & safety qualifications and confirming to IEC 62804 PID.(j) It shall also be in conformity to latest minimum technical specification issued by MNRE/IREDA/SECI/NISE/ALMM from time to time. Modules should be of MNRE/IREDA/SECI/NISE/ALMM approved companies and as per latest IEC/IS standards. 6 (k) RFID reader is to be provided by contractor(l) Both PV cells and SPV modules shall be made in India (DCR).(m) Each structure should have angle of inclination as per the site conditions to generate maximum power. However, to accommodate more capacity the angle inclination may be reduced to 10 - 13 Degree until the plant meets the specified performance ratio requirements.(n) Fire Points with Fire extinguisher liquefied CO2 gas of capacity 10 kg and adequate qty confirming to relevant IS or ISI mark complete as recommended by manufacturer deemed to be included in the unit rate quoted.(o) Danger Board and Rubber mat as recommended by manufacturer deemed to be included in the unit rate quoted.(p) S&F Pressure Booster pump electrically operated with minimum 3 HP 02 Nos (Running+ standby) three Phase AC Supply motor and having head not less than 20 mtr, including PCC foundation civil wokrs and necessary cable required for connection in drawn in PVC conduit heavy duty/ DWC/Electrode pipe from existing nearest point to the motor starter panel including motor starter suitable capacity,PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm/50 mm/32 mm/25 mm inner dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brass threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches with necessary exavation, removing and returning filling work and including all accessories from the new PVC tank cap 10000 Ltrs install at proposed site for cleaning of entire solar power plant system.(q) SPV Panel is to be fixed in such a way that lower portion of the Panel remains atleast above 1.5 mtr of finished reflecting surface and cost deemed to be included in the quoted rates. 7 (B) Junction Boxes: Junction boxes of suitable Nos (as per design)/OEM recommendations inputs and suitably rated out put having separate DCfuses for both (+)&(-) on input and isolator on output terminal for each string.Each junction box must have as pare input terminal.The junction boxes shall be dust and vermin proof and water proof made of FRP/ Thermo Plast with IP 65 protection in compliance with IEC 62208 and shall be UV resistant, fire retardant. It shall have surge protection and maintenance free earthing as per relevant standard. The junction box shall have suitable arrangement of the following: (a) The strings are required to be connected to the copper bus bar through individual fuses. (b) Provide arrangement for disconnection (DC dis-connection switch) for each SJB/ SCB. (c) To provide a test point for each sub group for quick fault location and to provide group array isolation. (d) Each array box shall be of relevant IEC standard. (e) Each array junction box shall have suitable bypass & reverse blocking diodes for minimum DC blocking voltage of 1000V with suitable arrangement of its connection. Reverse blocking and bypass diodes shall work for extreme temperatures and shall have efficiency of 99.98% confirmed by appropriate IEC standard. 8 (C) DC Cables: Suitable size of XLPE insulated tinned Copper cable (min 10 sqmm) of solar grade, 1100 Volts and UV resistant for outdoor installations confirming to IEC : 60227/15694 & 60502/ IS : 1554 (Pt I&II)) and shall be as under : (a) All cables and connectors must be as per IS/IEC standards and shall be able to withstand harsh environmental conditions including high temperature, UV radiations, rain, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS. (b) All the cables / wires shall be provided with UV resistant printed ferrules for DC wires. (c) The size of the cable shall be such that average voltage drop at full power from PV module to inverter shall be less than 1.5%. (d) Cable batch No., Drum No, IS code and size and make shall be mentioned on every one meter or as per OEM practice. (e) The wiring of the module interconnection shall be in UPVC/HDPE pipe of suitable size. (f) The cost of interconnecting DC Copper cable, MS cable trays, MS cable trays suitable to accommodate Solar grade cables from SPV module to inverter are included in the item. 9 (g) Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain ant type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore will be repaired and make good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes, exavation, removing, return filing, channel, any type of metal work is not measured and paid separately under relevant items.(D) Module Mounting Structure (MMS) (Suitable for ground mounting on any type of soil condition) :Design, procure, fixing, support structure made of hot dipped galvanised steel with min 85 micron thickness including necessary PCC / RCC foundation and associated work (cutting, grounding, PCC filling, disposing waste material,etc., complete) and fixing mounting arrangement suitable for SPV modules so as it can with stand wind speed of 170 km per hour & minimum yield strength off 250 MPa. The mounting structure is to be installed on ground. Mounting structures to be so designed that maximum load is directly on ground. It shall also observe minimum space without sacrificing the out put of SPV panels & adequate spacing between the arrays shall be available for easy cleaning and maintenance. Nuts, bolts, protected from the atmosphere and weather mounting structure shall have to be adequately of Stainless Steel of grade SS316. 10 NOTES :- (a) Two numbers of anti theft fasteners of Stainless Steel on two diagonally opposite corners of each module shall be provided. (b) Module mounting structure shall be fitted to provide maximum generation. (c) MMS design shall be supported with Staddpro Report vetted by Third Party (Gov Institute) and submitted for the approval of the Accepting Officer. (d) The height of approved design MMS for solar power plant shall be as per latest MNRE/IREDA/SECI/ NISE guidelines. (e)Minimum grade of RCC M-25, design mix (using 20mm graded crushed stone aggregate includingTMT bar as per design, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete and other connected works as per design and OEM recommendation. Civil work shall be designed through approved consultant of MES as per latest MNRE/IREDA/SECI/ NISE guidelines and vetted by IIT / NIT.(E) Lightning Protection forentire Solar Power Plant (i.e PV Array, Inverter etc) : Design, procure and fix lighting arrestor system confirming toIS/ IEC-62305(Part1-4)on the ground. The air terminal shall be fixed at the top of MS pole with base so as to beat least two meter above the pole to be protected. Its height above 9 mtr level shall be depend upon the level of protection and protection radii required. 11 NOTES :-(i) The cost of all equipments, MS Pole, Copper strip upto earth test point,LA, etc., shall be deemed to be included in this item. (ii) The cost of sufficient earthing for lightning protection is also included in this item to be provided by Engr-in-charge. and no extra payment will be made to the contractor on this account (iii) The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account. In case of any dispute, decision of Engr in charge will be final, conclusive and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474). Earth resistance shall not be more than 3 Ohms. (iv)Separate LA arrangement & the design document of the same shall also be submitted. (v) The protection against induced high voltage shall be provided by the use of metal oxide varistors and suitable earthing such that induced transient find and alternate route to earth. (vI) SPV Power Plant shall be provided with lightening and over voltage protection. (vii) Internal surge protection shall consist of three MOV type surge-arrestors connected from +ve abd +ve terminals to earth (via Y arrangement) 12 (F)Power Conditioning Unit: Procure, fixing, testing and commissioning of minimum 4 (Four) unitswith overall not less than 800 KW output on 11 KV AC supply, Solar-power inverter suitable for without DC power of Solar PV module/ array with AC output further feeding to grid confirming to IEC:61683 for efficiency, IEC:62109-1 or equivalent for safety and IEC:62093 for reliability. The input DC & output AC technical specification of Inverter are as under :Input (DC) (a) Max Absolute DC input Voltage : 1000 V (b) Start-up DC input voltage : 200 - 500 V (Default 420V) (c) Operating input DC voltage range : 200 - 1000 V (d) No of independent MPPT : One (e) MPPT input DC voltage range at Pacr : 180 - 1000 V DC (f) Max input DC Current : As per design. (g) AC grid connection type : 3Phase (4W + PE) (h) AC output power : As per design. (j) Max AC output Apperant power : As per design. (k) Max AC output Current : As per design. (l) Max AC fault current : As per design. 13 (m) Nominal Output Voltage : 800 Volts AC 3phase or as per the design of Solar Stepup Transformer (n) Output voltage range :± 10% (o) Output Frequency : 50 Hz ± 3Hz (p) Power factor : > 0.99 (q) Harmonic Distortion Current : < 3% (r) Efficiency : > 98% (s) Standby operation consumption : < 1.5 W(t) Operating temperature upto 85 degree centigrade (u) The Copper based inverter shall have minimum IP-67 protection, ground fault monitoring, reverse polarity protection, anti-islanding, DC reverse polarity, AC and DC short circuit current and over current, AC and DC over voltage and over temperature. 14 (v) The inverter shall adjust voltage and frequency levels to suit the grid. (w) The inverter shall be self commulated with Pulse Width Modulation (PWM) technology and shall be capable of synchronise maximum with in one min. (x) Maximum Power Point Tracker (MPPT) confirming to IEC 62093 shall be integrated in the inverter to maximise the energy drawn from the PV array (y) Monolithic design of inverter is not permitted. (z) Shall have anti-Islanding features. (aa) The inverter shall have suitble nos of protected inputs (asper design) and outgoing shall be protected by ACB/MCCB. (ab) The inverter should have MODBUS, PROFIBUS, ETHERNET common ports. (ac)The inverte rshall include appropriate self protection and self diagnostic features to protect itself and the PV array fromthedamageintheeventof invertercomponent failureor fromparametersbeyondtheinverterssafeoperatingduetointernaland/orexternalcauses. Invertershallhaveprotectionarrangementagainst ground leakage faults, over voltage, (SPD) & over current. Inverter shall have arrangement for adjustment for adjusting DC input current and shall trip against sustainable fault down stream and shall not restart till fault is rectified. (ad) The inverter should have provisions of Galvanic isolation, anti-islanding protection (IEEE 1547/UL 1741) equivalent IS and lightening. (ae) PCU must have the feature to work in tandem with other similar PCUs and be able to be successively switched ON and OFF automatically based on solar radiation variations during the day. (af) Minimum Warranty of Inverter- 12(Twelve) Years and defect liability period deemed to amended accordingly for the said item. 15 (G)ACDB : Outdoor type powder coated weather proof,vermin proof made out of CRCA sheet front open able door, lockingarrangement, including suitable working space in DCDB busbar chamber, cable box chamber including Copper busbar of designed capacity /bus raisers suitable capacities with PVC sleeves/tape RYB colour for phases identification, including all bus raiser shall be extend upto cable box chamber fixed on fibre insulation for RYB & neutral to all out going cable, confirming to IP-65 and fixed on wall / floor with control wiring with comprising cable gland brass, copper lugs etc. and comprising the following as per design :- (i) MCCB 4Pmicroprocessor based for outgoing (ii) MCCB 4Pmicroprocessor based for incoming (iii) AC type 2 Surge Protection Device (iv) Spreader Terminals as per requirement (v) Multifunction meter (vi) CT of suitable ratio(vii) Copper busbar chamber (ix) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 16 (H) DCDB:- Outdoor type powder coated, weather proof, dust proof,vermin proof made out in CRCA sheet front open able door, looking arrangement, including suitable working space in DCDB busbar chamber,cable box chamber including copper bus raisers with PVC sleeves/ tape RYB coloursfor phase identification, including all bus raiser shall be extend upto cable box chamber, confirming to IP-65 and fixed on wall /floor with contral wiring with comprising cable gland brass, copper lugs etc. (i) MCCB as per requirement (ii) Fuse as per requirement (iii) Copper busbar chamber. (I) Weather Monitoring System Pyranometer : The pyranometer (ISO 9060 classification ) alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specifications of the pyranometer shall be as follows :- (i) Spectral response : 031 to 2.8 micron,(ii) Time response (95%). Max 15 second 17 (iii)Nonlinearity + 0.5% (iv) Temperature response : - 2%(v) Tilt error <+/- 0.5% (vi)Zero offset themal radiation +7W/Sqm (vii) Zero offset temperature change + 2 W/Sqm(viii) Operating temperature range - O °C to 80°C(ix) Non stabillity Maximum - 0.8%,(x) Resolution minimum +/-1 W/Sqm (xi)Output Analog 4.50mA (xii) Digital RS 485(xiii) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 18 (J)Balance of System(BOS) Items/ Components:TheBOSitems/componentsof theSPVpowerplants/systems deployed under this project shall conform to the latest edition with certificate of IEC or equivalent BIS Standards/MNRE specifications/ as specified in Para 1.01 of Minimal Technical Requirements/ Standards for SPV System/Plants to be deployed during this financial year under the programmes of MNRE available on MNRE website as on last date of quoting of tender. Notes:(i) The contractor must visit the site before quoting the rates for this item to assess the site condition so as to decide up on location and layout of SPV, placement of inverter, length of DC cables, lightning arresters, etc., complete. (ii) The contractor shall submit complete scheme including electrical diagram of the work, schematic diagram, SPV module layout, placement of LAs, Civil work, etc., complete as per IREDA/ SECI/NISE/MNRE/ALMM latest guidelines as applicable, Relevant IEC/IS norms to the GE for approval with in one month of date of commencement of the work. (iii) The rate quoted is deemed to be inclusive of the all protection system including surge, lightning arresters and necessary earthing all as specified and directed. 19 (K) Remote monitoring system (SCADA) for solar power plant complete with all electronic andelectricial partswith andincluding all necessary software and hardware etc to make fully functional connected to LED monitor (55 inches) with complete plant parameters as required and operate the system from remote and Other Accessories includingandThe system will be controlled from the main control room where all the data from different parts of the plant shallbe received, analyzed and action taken either manually or on auto as per the system design by OEM . The SCADA shallhave remote monitoring capability comprising with the following Items and with and including all connectedaccessories as per OEM recommendation complete:(a) Main SCADA control wall mounting panel complete with fixing arragnment like nut bolt, washers suitable size and connected items. (b) LED Moniter (55. inches) with mouse, key board, CPU (Minimum 1 TB storage alongwith 12 GB RAM, i7 processor), key pad and single phaseUPS 10 KVA with 12 Volt battery, 14400 Ah battery bank with rack and required battery backup should not be less than 4 Hrs inside control room.(c)“SCADA System shall be audited for Cyber Security by CERT certified firms at the time of commissioning. Subsequent cyber security audit shall be carried out after every 03 years and cost of audit and rectification shall be born by the contractor” 20 The Contractor shall provide following defined user access levels, unless otherwise instructed by the Engineer-in-Charge: -• Normal viewing only (default level) The default level shallpermit users to view al displays except those specifically assigned to a higher level of access.• Dally Access The daily access level shall allow viewing (ie default an printing at trend displays.• Operator Level (Remote Control) The operator level shall permit authorised users to access lower levels a and to carry out the following actions:- Perform control actions Acknowledge alarmsEnter or modify manually-entered data for inclusion in thereports.• Monthly and Yearly Data Archiving The level shall permit authorised users to access lower levels and shall provide the facility to download specific data to long ten data storage for archive purposes(d)The SCADA software shall be of a proven design and reliable, and conforming to industrial standards and shall: -• Support multiple makes of RTU/ Microprocessor controller/ transmitters and models and provide required software features needed to easily adapt a device whichshall not be supported as standard to the SCADA system. 21 • RTU/ PLC/ Microprocessor base controllers and transmitters shall have an expandable architecture and scalability to provide future capacity increases in SCADA system as well as meet present needs of the administration, provide multi-level security and password mechanisms to prevent use of the system by unauthorised persons. The access privilege of authorised users shall be defined separately and permission shall be provided to the users only to access areas concerning them, provide an on-line operatingenvironment.• Adding a new RTUI Microprocessor based Controller to the SCADA system or changing configuration of the existing RTUs/ Microprocessor based controller shall not result in stopping or hinder working order of SCADA system.• The Contractor shall specify maximum number of data which shall be achieved by the system without any performance loss. The Contractor shall conduct necessary tests to prove maximum number of data points achieved. The Contractor shall also be responsible to create additional data points necessary for conducting such tests. Any AutoCAD graphics shall be able to be converted to process diagrams and shall be re-loaded and operated after completion of all works and during tests.(e)The Contractor shall hand over to MES the SCADA and application software (as CDs or DVDs) necessary for re-loading software to the system in case of failures The CDs or DVDs shall be provided after making the necessary tests. The operating system ofrouters and work stations shall be of an architecture that provides a multi-tasking operating environment, and SCADA software shall also be multi-tasking. Therefore multiple tasks such as receiving measurement results from devices, displaying these results on computer screen. storing on a computer disk, sensing alarm conditions that may occur based on measurement results, and displaying them to users, generating reports from collected data, and printing them cut, transferring issued commands to Microprocessor controllers/ RTUs/ PLC, that SCADA software is supposed to execute shall be handled simultaneously without one task waiting for another. 22 To configureSCADA software or to change the system configuration, definitions shall be either defined directly by using a keyboard or another interactive tool or mechanisms that allow importing of configuration definitions from a text file created with a text editor. The database configuration shall be provided by means of an interactive program that contains menus or similar approaches and shall be easy to use The database configuration definition program, when required, shall be capable of extracting definitions related to the configuration from information created in text format to use as definitions for configuration The following shall be possible online without interruption or hindering of usual operations: -•Adding an RTU to the SCADA system.•Deleting an RTU from the SCADA system•Changing configuration information related to an existing RTU definition.•Modifying definitions in database containing information about measurement and control points.•Creating screen pictures which offer operators to monitor and control the SCADA system.•Similar configuration changes. 23 (f)SCADA software shall be upgradeable to new versions with an automatic mechanism to be provided by the Contractor. The old version of software shall be overwritten by new version without resulting in a change in any of the definitions created in previous version, nor disturbing the operational logic defined in previous version. Al! text being available on the screen shall be in English language The database shall be configured on-line when the SCADA system shall be in operation. The changes on existing definitions or new definitions related to database shall be made when the data collection n and control functions are being performed. The SCADA Software shall be operated using the database that shall be resident in the memory(g)Data Exchange The control system shall provide a method of real-time data exchange with different application programs like Geo Information System (GIS). relational database, third party spreadsheet packages, report generation and graphical simulation packages.(h) Historical Data Management An historical data management (HDM) system shall be provided for archive, storage and retrieval of operational data comprising field input data, manually-entered data and calculated points Archived historical data shall minimally include averages, minima and maxima for each analogue value compiled over hourly. daily and monthly time periods, with a minimum capacity of 1o00 points. The HDM system shall be capable of selectively increasing the rate of data capture based on events, such as process variable status, discrete inputs, or operator command. Minimum and-maximum data shall include the time and date of occurrence. Gaps in collected data caused by faulty instruments or control system equipment shall not be included in average). minimum and maximum compilations. 24 (j) Report GenerationThe system shall be provided with a report generator utility which shall enable authorised users to create, delete or modify report definitions The report definitions shall allow for retrieval of data from on-line database and farm historical data files and for formatting data for output to printer. The format of each report shall be definable by user to include the definition of static or background data, placement of data base values, number of significant digits of a value, date and time of report and calculated values(k)Graphic Display GenerationThe system shall be provided with an interactive on-screen graphic generation utility which shall allow an authorised user to create new graphic displays and modify or delete existing displays at any work station including those associated with the LCP/ outstations. The generation utility shall include an interactive linkage process allowing user to link symbolic, numeric and bar graph representations and data entry locations to dynamic data base variables. The graphic display system shall be capable of making full use of the VDU resolution in the composition and display of graphic information. Graphic symbols shall be definable by the user for display of static and dynamic data. The user shall be able to as5emble a library of symbols which shall be retrievable into any graphic display. Text and symbols shall be able to be enlarged, shrunk, moved, mirrored or related with reference to a given display. The system shall be able to represent dynamic analogue data on a graphic display as a variable-length, sizeable bar graph, as well as numeric text. 25 (l)DisplaysGeneral all displays, excepting those containing data derived from historical files, shall be completely displayed within two seconds of the operators request. Dynamic data shall be continuously updated while being displayed. All screen displays shall provide following displays which shall be fixed in their locations to normal operations:• Alarm banner window at bottom of the screen display showing last three highestpriority unaccepted alarms. Where the system allows contents of banner to be limited (eg by user name or group) then the selection criteria applied shall be displayed with the banner.• Main display area for user selected displays e.g. mimics, alarm lists, etc.• System dialogue banner window at bottom of the screen shall display relevant system information such as error message and user prompts 26 •A day, date and time indicator shall be able to show local time an alarm bannerarea shall be included on all displays which provide information regarding most resentalarm events. The system shall allow operator to obtain details of most recent alarm event from any operational screen display through direct operation using a maximum oftwo keystrokes or selections. The system shall allow the operator to obtain a print of any display, including graphics through use of a standard system command. Screen displays shall appear identical incorporated form Dynamic data contained on a display shall not change during screen print Such that a snapshot of conditions is portrayed. Each display shall include time of day in hoursminutes and seconds and date in day, month and year format.•A facility shall be provided which allows paging to related displays through the use of ‘page forward or backward keys, or through the use of pick points(m) Suitable size of HT & LT XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts and 1100 Volts grade with stranded aluminium / copper conductor of size as per OEM recommendation and approved design ISI markedincluding cable glands, lugs, jointing kit etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories and necessary earthwork, civil work deemed to be included in quoted rates of the above items.(n)Generic Displays.The system shall produce various generic displays automatically 27 Metering arrangements: (A)Suitable bi-directional metering arrangements with recording facility shall be provided as per the norms of WBSEDCL. The metering arrangements must have feature to measure and record, (i)Parameters of KW, KWh, KVAR, voltage, current, PF and any other metering required to determine efficiency and efficacy of the system. (B) LT 3 Phase 4 Wire Electronic Tri vector Meter with CT ratioshould be as per capacity of SPV plant. (i) Standard: IS 13779:1999 / CBIP 88 (ii) Accuracy: Class 0.5 (ii) The metering arrangement shall have inbuilt Solar PV Plant synchronisation features. (iii) Reference Voltage - 3x240 V (iv) Basic Current (Ib)- 5 A (v) Maximum continuous current (Imax) - 10 A (vi) Rated Frequency (variation) - 50Hz (±5%) 28 (vii) Power consumption:- Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency Current circuit: Less than 1 VA per phase at basic current, reference frequency and reference temperature (viii) Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height (ix) Display in the event of Power Failure: Internal battery back-up for LCD display (x)Communication port: Galvanically isolated Optical Communication port for data transfer through either CMRI or remote device or both is providedwith RS 485 for DLMS protocol (C) CT/PT operatedenergy meter with following features (i) True four quadrant metering (iii) Time and day metering with maximum demand registration and automatic billing (iv) LCD display with announciators for various critical events (v) Scroll lock feature for continuous display of a desired parameter on display (vi) High resolution energy display mode for dial test (vii) DLMS protocol for meter reading, with option to remote reading port. 29 (viii) Advanced event detection features for voltage, current and magnetic influence (ix) Meter reading in absence of mains, using internal battery. (x)Power Manager Device Nano type with 4 inverter support with energy monitoring, zero export control, Load Management having RS-485 communication port, ethernet including RS 485 cable core size 0.5-1.5 Sqmm to establish communication between inverters, SCADA and sensor as per OEM recommendation with and including all connectedaccessoriesdeemed to be included quoted rates.(xi) Digital WIND SPEED SENSOR withminimum 3 cup Anemometer range 0 to 70 Mtr/ Sec distance constant 2.5 Mtrs output TTL Pulses output proportional to wind speed and diameter of cup 50mm with brass housing and stainless stell shaft(xii) WIND DIRECTIONSENSOR with wind vane and sensing vain coupledto linear endlsess potentio meter IP 67, range 0-357degrees, operating temperature -40 to +60 degrees celsiuswith brass housing and stainless stell shaft and aluminium vane complete 30 (xiii) AIR TEMPERATURE SENSOR withRTD sensing element PT100 mounted inside a weather shield duly coated with weather proof reflective white paint , range -40 degree to +60 degree celsius with nylon body housingwith weather shield and brass stem to mount the sensor, includingpower requirment 5 Volt DC complete. (xiv) MODULE TEMPERATURE SENSOR Model PT 1000 measuring range -40 Degreeto + 80 Degree Celcius with suitable ouput as required and directed on site and mounting on RTD encapsulated in suitable housing including connecting cables as required complete.(xv)Tipping Bucket Rain Gauge with Magnet and Red Switch type Sensing, rim diameter 203 mm and collecting are 335 MM SQ, Rain gauge shell made up of FRP bucket and mounting made up of stainless steel SS316 and unlimted capacity,including connecting cables as required complete.(xvi)SOLAR Radition Sensor ARN 8101 with 72 element thermo pile sensor and spectral range 0.3 to 3 Micro Mtrs and sensitivity 20 Micro Volt/ W/M², range 0 to 1500W/SQM & output 0 to 25 milli Volt and operating temp -10 to 70 Degree Celsiusincluding connecting cables as required complete with all fixing arrangment and necessary civil work complete with including all connectedaccessories as per OEM recommendation/Designcomplete: 31 (L)Step up solar transformer (800 volt/11 KV)” - Design,procure,erection, installation, testing and commisioning including connecting to local utility grid :Oil filled Type 3 phase, 50 Hz, ONAN cooling type, vector group of appropriatetype, number of load voltage Ratio: number of Phases / Freq.: 3 Phase / 50 Hz., Sealed type Copper wound Transformer with Off Load Tap Changing Arrangement on HV side in steps of 2.5% , +5% to -10% having cable end boxes on HV side suitable for 3 Crore X 300 Sq. mm. XLPE cable of 11 kV grade on HT side and LV side complete with all accessories like buchholz relay, Oil temperature indication, winding temperature indication and alarm etc preferbly DMCR Protection Relay i/c first filling of filtered dehydrated K Class natural Ester Oil bioTransol (as per IS 16659) and confirming to IS 1180 and losses shall be as energyefficiency Level 3 only & 100% load phase, with an impedence of 6.25% i/c as per specification below complete in all respects as required at site. Design ambient to be considered as 50 Deg C.All the balance parameter like temp rise, Basic insulation level, flux density etc shall be strictly in accordance with IS 1180 Part - 1 only including necessary earth work, PCC plinth foundation etc.Heat Run Test is the mandotary test for each Transformer.Standard: The equipment shall conform to the latest edition of applicable standards as follows. In case of conflict between applicable standards and this specification, this specification shall govern.• IS 2026 Standard for Oil filled Transformer• IS:3639 for Fittings and Accessories• IS:2099 for Bushings > 1000 V• IS:7421 for Bushings < 1000 V• IS:1271 for Electrical Insulation classified by Thermal stability• IEC 62770 Natural Ester Oil• CBIP Guidelines 32 (xvii) CORE : Transformer shall be double wound, core type with low loss, non-ageing, high permeability PRIMEGRADE, CRGO with M4 Grade or Better, perfectly insulated and clamped to minimize noise and vibrations. Followings should be Mandatory for any manufacturer: -(a) Transformer shall be of BOLTLESS core design.(b) Core shall be purchased Directly from Manufacturer or from their accreditedMarketingorganization of Repute & not through any agent. Bidder has to submit manufacturer’s name during bidding having sufficient credential & Core has to be purchased from the approved manufacturer.(c) Stage inspection of the core shall be done at manufacturer’s premises & inspection call shall be given with following Documents: (i) Invoice of the supplier (ii) Mill’s test certificate (iii) Packing list (iv) Bill of landing & Bill of Entry certificate by customs(d) Transformer manufacturer should have in-house core cutting facilities for proper control & monitoring of quality & to avoid mixing of Prime core with Second grade /defective core materials. Transformer Manufacturer should have in-house slitting Machine so that core is cut to width & stacked with minimum air gap thus ensuring Burr level less than 10Microns.(e) Core shall be procured from one of these reputed Manufacturers : Posco / Nippon/ Novex/ Ak Steels.(f) The insulation structure for the core to bolts and core to clamp plates shall be such as to withstand a voltage of 2000V for one minute. 33 (xviii)Tank:Tank should be of corrugated wall construction type. The exterior of tank and other steel surfaces exposed to the weather shall be thoroughly cleaned and have a priming coat of zinc chromate applied. The second coat shall be of an oil and weather-resistant nature, preferably of distinct colour from the prime and finish coats. The final coat shall be of a flossy, oil and weather resisting non-fading paint of specified shade. The interior of the tank shall be cleaned by shot blasting and painting with two coats of heat resistant and oil insoluble paint.Winding:(a) Winding shall be made with 99.9% pure electrolytic grade copper, insulated with thermally upgraded paper (Insulation Class A / Conductor Turn Insulation-Class E).The HV & LV winding should be able withstand thermal and mechanical stress in the event of short circuit.(b)Winding shall be carried in dust free area(c) The completed core and coil assembly shall be dried in vacuum and shall be immediately impregnated with oil after the drying process to ensure elimination of air and moisture within the insulation.Oil type: TransformerTransformer oil shall be as per IS-335:1993. It shall be natural/synthetic ester oil. The material safety Data Sheets (MSDS) for the Transformer oil shall be submitted by the bidder along with the offer Temperature Indicator:One set of winding temperature indicators with necessary current transformer, heating coil and a detector element and one set of oil temperature indicator with maximum reading pointer shall be mounted locally so as to be readable at a standing height from ground level. Each of the above indicators shall be provided with necessary contacts for alarm and trip: (a) Oil Insulation class : K class. It should also exhibit safety against fire hazards 34 (b) Cooling : ONAN(c) Vector Group: to be decided during design.(d) Percentage Impedance (Z%) 6.25 %.(e) Transformer Losses:as per IS 1180 - Level 1(2021)(f) Taps on HV for HV variation : +5 to -10 % in steps of 2.5% each (g) Termination (HV): Cable End box for11 KV cableof suitable size(h) Termination (LV): Cable connection(j) The transformer shall be supplied with following fittings:(k) Lifting lugs and Jack lifting pad support(l) Earthing terminals - to be decided during design. 35 (M)Earthing :The complete system shall include chemical earthing of required quantity for step-up Transformer (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account in case of any dispute decision of Engr in charge will be final and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 36 IMPORTANT NOTE FOR SOLAR POWER PLANT CONTRACT (COST DEEMED TO BE INCLUDED IN QUOTED RATES :-(1) The item specification and details given are for guidance purposes only and are likely to vary with modified / higher specification than that specified in the BoQ based on detailed site survey, solar potential assessment, design approval etc keeping the quantity of Solar inverter (PCU) and Solar Transformer same as in the BoQ. The items as per the finalized and approved design and specification, including make, shall be provided by the contractor without any extra cost to the department. All makes should be as per the latest MNRE approved list of makes and models.2.Cost of preparation of DPR design vetting from NISE/MNRE approved Institute and net billing arrangement (as per WBSEDCL) is deemed to be included in the quoted rate.3.The contractor shall submit complete design of Solar power plant, Schemetic/line drawings, detailed mounting structure array layout drawings alongwith SBC report based on the soil investigation as per OEM recommendation, Single line diagram with and including project reportand connected document shall be submitted by OEM through contractor prior to commencement of the work for approval of Accepting officer and subject to the drawing and designduly vetted by IIT/NIT (for mounting structure only) and vetted by NISE/ SECIfor entire scheme of Solar Power GenerationProject including evacuation and Net Metering arrangement complete before recommendation by GE for approval of the accepting Officer. 37 (i) The scope of works involves engineering, procurement & construction (EPC) of entire Solar Power Plant of capacity 0.8 MWp.4. The entire work shall be executed directly by OEMonly through contractor and contractor has to submit the MoU with OEM (agreement period for 25 years of entire Solar Power Plant Project) prior to commencement of work and same shall be approved byGE. 5. Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain any type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore have to berepaired and made good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes for entire Solar Power Plant Project, exavation, removing, return filing, channel, any type of metal work is deemed to be included in the quoted rate. 38 6.Cost of comprehensive maintenance as per OEM recommendation alongwith cost of spare parts required during 5 years of defect liabilty period after completion of Ph-I is deemed to be included in the quoted rate.7. Bidders attention is drawn to pre-bid conferance with department and also visit the site prior to bidding and other factor required as per OEM recommendation deemed to be included in quoted rates.8. The contractor has to carryout Pre-commissioning test of solar power plant including stepup transformer by CEI/SEI. The necessary tools and plants required for inspection of the plant shall be arranged by the contractor.and costsare inclusive in quoted rates.9. Contractor needs to know the irradiance of the location at the project before quoting. The contractor will design DCR (Make in India) for entire Solar Power Plant according to irradiance of the project location and efficiency of the components to produce the desired peak value as mentioned in the schedule i.e. 800 KW output on 11 KV AC supply and inject to the proposed RMU 11 KV. 10. During the execution of work any type of damage by elephant or monkey manance, contractor is fully responsible for protection of all solar power plant equipments including connected items i.e. PV Module, Inverter etc. No claim will be sought from the department. 39 11. All SCADA related activities viz. cables till SMBS and inverter and the requisite software and hardwarefor control room shall be included in the quoted rate.12. Vegetation Growth should be controlled by use of Deweeding Chemicals deemed to be included in Quoted Rates.13. Adequate Water Storage Facility of capacity 10000 Ltrs PVC Tank 5 Layer (with guarantee of 10 years after physical completion of work) on PCC Platform including suitable foundation for cleaning of PV Modules and suitable water drainage facilitiesfor both (Rain Water and Cleaning Water) from proposed site to existing drainage chamber is deemed to be included in the quoted rate.14. Solar Transformer fed from the Inverter should not be having odd harmonics (certificate needs to be required before physical completion of work).15.The Shutdown duration of Inverter should be monitored and recorded and analyzed. 40 16. The SPV Power Plant will be capable of generating 800 kW AC Output atleast once in a year and the AC Output of the plant will be not less than 90% of initial output by the end of 10 yearsand not less than 80% of the initial output by the end of 25 years.17. The Contractor shall operate and maintain Fire Protection System and safety equipments for the entire Solar Power Plant for 10 Years and cost of the spare is deemed to be included in the quoted rates.18.The firefighting system for the proposed power plant for fire protection shall be consisting of:a) Portable fire extinguishers in the control room for fire caused by electrical short circuitsb) Sand buckets in the control roomc) The installation of Fire Extinguishers should conform to TAC regulations and BIS standards. The fire extinguishers shall be provided for control room housing, PV array installation.19.Solar Components shall not be connected to LAN, WAN, or any Internal Data/OPS nw. 41 20.Sys with Bluetooth, GSM, Wi-Fi, or any Telemetry features should be avoided, unless explicitly cleared monitored.21. Finalization Of Feasibility Report, Design, Engineering, Transportation, Storage, Insurance, Civil Works, Erection, Testing & Commissioning etc., ensuring net-billing as per state net billing policy, quality control of grid connected.22.The Comprehensive Maintenance of SPV Plant would include wear, tear, overhauling, machine breakdown, insurance and replacement of defective modules, Inverters/PCU, spares, consumables & other partsas pe OEM reocmmendation and specification for 5 (Five) years under DLP of Phase-I..23.The Contractor shall arrange technical vetting of the plant during execution by the Cyber/INT officer and training by Unit Technical Pers till defect liability stage of Phase-I. 42 24.a) An energy meter (for net-billing) shall be installed between the solar Grid-tied inverter and the building distribution board to measure gross solar AC energy production (the Solar Generation Meter). The Solar Generation Meter shall be of the same accuracy class as the DISCOM service connection meter or as specified by local regulatory requirements. Separate for two different buildings.b) The bidder must take approval/NOC from the Concerned DISCOM for the connectivity, technical feasibility, and synchronization of SPV plant (if required).c) Contractor shall be provided system software (Cloud) for data hosting of Solar Power Plant with the Government approved agency and also audited by CERT-In (Computer Emergency respose team-India) is deemed to be included in the quoted rates. 25.a) Two sets of Engineering, electrical drawings, and Installation and O&M manuals are to be supplied. Bidders shall provide complete technical datasheets for each equipment giving details of the specifications along with make/makes in their bid along with the basic design of the power plant and power evacuation, synchronization, along with protection equipment is deemed to be included in the quoted rates. 43 b) All test and calibration certificates, wherever applicable.26. The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.27. (a) The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.(b) The contractor will carry out fortnightly, monthly, quarterly and annual maintenance as per Proforma of Appendix here-in-after respectively. In case the contractor fails to carry out the above maintenance following penalty per Solar will be imposed. 44 (i) Not carrying out maintenance fortnightly- Rs 2500.00(ii) Not carrying out maintenance Monthly- Rs 5000.00(iii) Not carrying out maintenance quarterly- Rs 7000.00(iv) Not carrying out maintenance annually - Rs 10000.00(c) The Contractor shall be responsible for ensuring production of 800 kW AC output of electricity at the injection point of RMU atleast once in a year from the SPV plant. In case the output is less than 800 kW AC unit, it will be deemed as under-designed plant. The contractor will be responsible for making good the shortfall by repair / replacement of the SPV Plant free of cost. Delay in this regard will attract monetary penalty to be amounted for the period wef very next day of the completion of Phase-I to the date of completion of rectification / replacement by multiplying the maximum value of units less generated than 800 kW AC for every day with the prevailing rate of electricity tariff of WBSEDCL Rate of electricity in West Bengal is Rs 6.52 per unit as in Sep 2025.(d) Maintenance and supervision shall be done by trained men for the safe operation of Solar’s contractor shall carry out fortnightly servicing including adjustment lubrication, repair of replacement fo parts if necessary. In addition to fortnightly servicing contractor’s senior mechanic of foreman shall carryout the inspection as per maintenance schedule and make necessary entries in the proforma attached here-in-after duly signed by Contractor & Engg-in-Charge as applicable kept in the switch room for this purpose. It will be the responsibility of the contractor to see that the maintenance schedule book is maintained properly by their senior mechanic or foreman. They shall promptly attend and call back & shall not be kept pending for more than 4 hours unless it has the prior approval of the Garrison Engineer. 45 (e) For any repairs/ replacement of Solar the contractor shall always be aware of time factor following are the fixed time (including Sunday/Holiday) for repair/replacement of parts/components/ accessories which shall be adhered to :- (i) Minor repair/ replacement- 4 hours (ii) Major repair/ replacement - 1day(f) The decision of the GE regarding Minor/Major repair shall be final conclusive and binding. In case of failure on the part of the contractor to keep the solar’s in running condition within the stipulated period mentioned in above the contractor is to pay penalty charges as mentioned below subject maximum of 10% of the total contract value and after that measurement will not be considered for the same defective Solar till it is in satisfactory working condition :-(i)Upto 12 hours @ 2000/-(ii) Above 12 Hours and up to 24 hours @ 5000/-.28. RFID Tag scanner of reputed make shall be provided by the contractor is deemed to be included in the quoted rates.29. Existing Room at 33 KV Switch Yard shall be used for SCADA/ Solar equipment/Control Room. 46 30. Surface preparation and laying of light yellow/white coloured interlocking tiles of appropriate thickness under the whole area of PV module array to make a reflecting surface for bifacial Solar PV module alongwith periodical water sprinkling arrangement for cooling of interlocking tiles is deemed to be included in the quoted rates. 31.The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes /LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines is deemed to be included in the quoted rates. Earth resistance shall not be more than 3 Ohms .32. The mounting steel structure shall be as per IS 2061-1992 and galvanizing as per IS 4759 and should withstand WIND Load as per relevant IS Code/NBC.33.Soil Stabliztion testing certificate needs to be required before completion of physical completion of work (Phase-I) so that the performance of the PV Plant is not affected in Highly Soiled areas for minimum 25 years. 47 34. M&O (Phase-II) should be finalize at the planning stage itself. The important point are as under:- (a) The thermal imaging of pv panel should be taken once a year for checking its health including hot spots.(b) The cleaning cycle of panel should be fixed as per the ratio of short circuit current falling below 0.9. The cleaning provision shoul be made available before evacuating the power.(c) The shutdown duration of inverter should be monitored and recorded and analyzed 48 Supplying, Installation, Testing & Commissioning including design, manufacture and testing at works of indoor type , IP 4X ,floor mounted metal clad, 11 KV VCB panel board totally enclosed & fully interlocked, Horizontal drawout, Horizontal isolation type breaker as per IEC-62271-100/200, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, motor charged and manually/electrically closing breaker suitable for use on 11 KV,3 Phase, 50Hz A.C. supply with STC 25 KA for 3 Sec.Internal Arc for AFLR 25kA at rated voltage for 0.1s at individual compartments i.e. Busbar, VCB and cable compartment.complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated and encapsulated copper bus bars of 800 Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 8 NO + 8 NC andequipped with following switch gears and accessories.The panel shall be complete with following switchgear and accessories. The structure of the switchgear must be fabricated using steel sheets coatedwith Alu-Zinc (Aluminium Zinc alloy)/PRINTED CRCA All major sub-components (switchgear, relays, meter & vacuum interrupters) shall be of same make. VCB and vacuum interrupters shall be designed for 100 short circuit operations at full short circuit of 25KA. Breaker shall be roll on floor type/ CASSET TYPE. Separate earthing truck shall be required for each bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth a live. It shall be provided with capacitive voltage divider and complete with audio visual annunciation, one for each panel. Item Continued as 2.01 to 2.04 49 INCOMINGS & Outgoing VCBs :Type : Air insulated VCB, autoreclosing, system voltage :- 11kV + 5%, 50 Hz+ 5%, 3 phase, rated voltage : 12kV, rated current : 800A in 40 ° C ambient, Short time rating for 3 sec : 26.3 kA, Short Circuit Making Current : 65 kA, insulation level (PF rms/ impulse peak) : 35 kA/75kA, System Ground : Solidly Earthed,Duty Cycle : 0 - 0.3 sec - CO - 3 min - CO, Break/ Make time :- Not more than 5 Cycle, Range for Auxiliary voltage for Closing / Tripping / Spring Charging : 85-110%/ 70-110%/85-110%. of rated voltage. The VCB must withstand 10000 mechanical, & 100 at rated short circuit current. The breakers should have auxiliary contact 6 No+ 6 NC, in minimum. The used Breakers will comply with IEC 62271/ IS 13118. Qty. - 3 Nos (1 no Incomer & 1 outgoings)Busbar: Rated Current : 800A @ 40°C ambient, Material : Silver Plated /Tined , High conductivity elecrolytic Copper Bus Bar sleeve :Heat Shrinkable PVC Sleeve with joints having full voltage soft PVC shroude Short time rating for 1sec :26.3kA -1 setCurrent Transformer:Voltage class: As specified in Circuit breaker ; Type: cast resin type, Dual core, Dual Ratio , Barden :10VA; Class insulation : Class E or better . Protection core: 5P10, Metering : 1.0 , Short time rating for 1 sec :26.3kA Ratio :300-150/1-1, 7 setsBus Potential Transformer: Rated Voltage : Primary - 11000 / ✓3 , Sec -110✓3; Type : Cast resin , draw out type, 3- phase , 3-limb complete with HV fuses . Barden : 100VA per phase ; Class of insulation : Class F or Better , Accuracy Class: 1.0;Rated Voltage factor : 1.2 continuous, 1.5 for 30 Secs. PT shouldbe drawnout type and serivce continuously shall be indepandent of Breaker trolly position...1set 50 Relay for Control & Protection: Numerical Type IDMT Relay (50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Additionally, condition monitoring CB wear, condition monitoring CT supervision, disturbance recorder, undervoltage & over voltage protection, trip circuit supervisioncan be measured through the relay. The device shall support webserver/web HMI through which we can monitor and control the relays over a ethernet Lan network. Licenses for theprogramming software shall be provided free of cost.The numerical relay shall have large mimic-based LCD screen display . .The relay shall have 8 Digital inputs and 8 Digital Outputs and one additional watchdog ouput.The device has to aloe controlling of min. six objects (circuit breakers, disconnectors and grounding switches). Controlling has to be done by “select-execute” or “direct control” principle. Controlling has to be possible by: through local HMI, remote communication, via digital input or via function key. Events has to be readable to SCADA systems, front panel or by setting software.The sample rate of the recording has to settable to 32samples/cycle.The devices shall provide storage up to events 2000 based on the resolution.The device shall support following communication protocols: Native IEC 61850 ed1 & ed2, Modbus TCP. The IEC 61850 communication has to support peer to peer communication (GOOSE) if requiredThe IEC 61850 interface must be able to configure through setting software. Also the same setting software has to be able to generate ICD filesThe device shall have KEMA IEC61850 edition 2 certificates - 3 sets. High Speed Master Trip relay VAX31- 3 Set, Ttrip circuit supervision relay-VAJH13-3 set6 Window Annunciation Facia . with ACCEPT, RESET & TEST Push Button - 3 set . Auxillary relay for Transmission faults (VAA33)- - 3 Set 51 Metering: Meters: 1-NosUL&CE Multifunction Digital meter displaying Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.Temperature Monitoring Sensor for the Three Phases of Incomer VCB Panel :Supply, installation, testing & commissioning ofthermal monitoring system to be provided to detect abnormal temperatures due to faulty connections and to prevent equipment B19damage. The switchgear shall have wireless temperature measurement sensors at all critical points:(a) 3 nos. foreach phase at incoming side cable joints The wireless temperature sensors installed on conductors shall be :(i) Installed with direct contact to hot point, to achieve accuracy of +/- 2°C(ii) Self-power (no auxiliary supply, no battery)(a) communicate wirelessly(c) Operate from -25°C to 125 °CThe system shall allow 2 configurable thresholds (pre-alarm and alarm). This system shall have integrated algorithms enabling to anticipate as early as possible an abnormal temperature, before damage occur (strong predictive capacity) and generate alarm through SCADA/monitoring software. Thermal sensor shall beself powered by the network current. Temperature data is sent via Zigbee wireless communication to provide high performance and accurate thermal monitoring. The sensor is secured to the connection point and is in direct contact with the measured point. Smartphones or tablets (with a Zigbee communication dongle) can be used with our Thermal Connect mobile application to scan data locally and can replace the need of periodic infrared scanning. Thermal sensors should comply to following standards:1 EN/IEC 61010,2010 2. UL 61010-12, 20123. ETSI EN 300238, 2012 V1.0.1 4. IEEE 802.15.4, 2013 52 Power Pack shall be with 220Volt AC Input & 24 volt DC continuous output suitable for closing /tripping indication of HT panel boards with 2nos 12Volt 100AH maintenance free batteries, chatging unit for trip system complete with suitable capacity dogital MFM connections with 2.5sq mm FRLS inaulated copper conductor cable etc as required.-4 set.The 11 KV HT Switchboard of 1 panel,shall bewith all accessories, interconnections,internal wiring, labels, space heaters etc. complete as required.3 panels shall be mechanically interlocked in such a way that only one operates at a time and multifunctional digital meters shall be interconnected and programmed in such a way that total consumption will come in one meter summating both of them.Note: 1. Quotated rates shall be inclusive of construction of foundation for the installation of VCB as per OEM drawing.2. The equipment shall be tested by SEI post sucessful installtion and report shall be submitted to this office. 53 Design, Manufacturing, Supply, Installation, Testing and Commissioning of 3 way 12 kV rated Ring Main Unit ofwith Fault Level 21KA 3 sec internal ARC 1 sec for tank and cable box , consisiting of 630A12 kV rated , 2 nos motorized type VCB as incomers & 1 load break switch as outgoings with metering modules along with necessary Earth Switches,battery and battery charger for shunt trip arrangement andMotor and other auxiliary circuit operation, HT CopperBus bar with current density not more than 1.6A/sq. mm as per detailed description as follows: RMU Construction: The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure to ensure the insulation and breaking functions. Sealed for life, the enclosure shall meet the sealed pressure system criterion in accordance with the IEC 62271-1 standard (§ 3.6.5.4): a volume for which no further gas processing is required during its entire expected life”. In addition, manufacturer shall confirm that maximum leakage rate is lower than 0,1 % / year. It shall provide full insulation, making the switchgear insensitive to the environment (temporary flooding, high humidity...), IP67 degrees of protection in accordance with recommendation IEC 60529 § 14.2.7. No SF6 gas handling required at site. Thus assembled, the active parts of the switchgear shall be maintenance-free and the switchboard shall be low-maintenance. The switchgear operating mechanism shall have an IP2X protection and cable chamber shall be IP55, Over all IP protection shall be IP55 . The tank shall be made of at least 2mm unpainted stainless steel. Item Continued as 3.01 to 3.05 54 VCB is the preferred dielectric medium for MV RMUs. Oil filled switchgear will not be considered. RMU shall be in accordance with IEC 60376.Any accidental overpressure inside the sealed chamber will be limited by the opening of a pressure limiting device in the lower part of the enclosure. Gas will be released to the rear or the bottom of the switchboard away from the operator and internal arc tested for both cable and tank for 21KA 1sec AFLR with test conducted with minimum 3 functions TankNumber of mechanical operations of Circuit breaker 2000 O/C , Number of electrical operations at full loop current for LBS: 100 O/C , Number of electrical operations at full loop current for CB: 2000 O/C,. Manufacturer shall provide type test report to prove compliance with IEC 62271-200 Annex A, Internal arc classification class AFL with 21kA 1s for the enclosure. Make of the RMU, vaccum intrtupter , relay & meter shall be of same OEM. All the test certificate shall be in the name of the OEM only . If there is any name change / acquisition by other OEM happened for the RMU then test cerificates shall contain the new OEM name only.HT System : 3 phase -3 wire , HT Fault level21 kA, Power System earthing - solindly earthed at up stream source, HT Copper Bus with Short Time Curent rating 21 kA for 1 Sec ( 3Sec), Continuous current rating at least 630 A. tank and cable chamberof RMU must be IAC rated for 21 kA for 1 Sec AFLR. Design ambient to be considered as 40 Deg C.HT Circuit Breaker :(i) There shall be 1nos.load break switches as incomings and 2 nos 12 kV rated VCBas outgoing ( total 3 nos.) . The circuit breakers shall be fixed type. All of the switchgear shall be capable of withstanding this current without any damage being caused, in accordance with the recommendations IEC 62271-1 and IEC 62271-200.Loss of service continuity class: LSC2(ii) The Circuit Breaker must be rated for 12 kV ( nominal Voltage), 28 kV/75 kVp ,3 Phase, 50 Hz, Short Circuit Fault Level of 21 kA for 3 sec. 55 (iii) No. Of Close Coils - 01 no. operable at 24 V DC (85% - 110%)/ Spring Assited Closing, No. of Trip Coils - 01 nos. ,operabale at 24 V DC ( 70% - 110%) for shunt trip.(iv) Provision for supervision of the shunt Trip Circuits for the Trip Coils to be provided. (v)Switchgear classification: PM class(vi) Loss of service continuity class: LSC2(vii) Duty Cycle : O – 3min – CO – 3min – CO, Vacuum Circuit breaker shall be of M1, E2, C1 duty and capable for minimum 50 short circuit breaking operation at full short circuit level.(viii) STC rating 21 kA for 3 Sec (for Vacuum Interrupter).(ix)Vacuum Interruptor must be hermetically sealed and must comply IEC 60056 ( along with latest amendments). Vaccum interrupter shall be of same make as RMU(x)Circuit Breaker to be equipped with Suitable tripping arrangement with push button, Mechanical counter to assess the total number of operations of the breaker, Mechanical ON / OFF indicator, Auxiliary switches, Auxiliary Contacts( at least 2 NO + 2 NC of Class 2 category), Emergency trip push button.(xi) The Operating mechanism shall be spring charged motor operated/ spring assisted as per OEM type tested design type with Spring Charge Universal motor operable on 24 V DC / 230 V AC.(xii)Suitable monitoring of Bircuit Breaker status ( ON, OFF, Trip, CB Spring charged if applicable), Trip Circuit Healthy / Unhealthy, DC healthy/unhealthyto be provided using (xiii) Voltage Presence Indicator shall be provided against each HT circuit ( against each VCB) on line side for knowing the presence of line enerzisation status.(xiv)Number of Mechanical operations at full rated current for breaker: 2000 O/C 56 HT CT /PT : Load Break Switch - 11 KV, 630A, 21KA for 3sec Motorized Load break switch; with built in line side manual earth switch. Earthing should be completed within 2 operations only(i.e 1. Main switch - OFF, 2. Earth switch - ON). LBS shall have 3 positions, open or disconnected, closed and earthed, and will be constructed in such a way that interlocking prevents unauthorized operations. For earth switch, manual opening and closing will be driven by a fast-acting /snap action mechanism, independent of operator action. LBS and earth switch shall have a min of 1000 (M1) mechanical operations ,and 5 nos closing operations at rated SC current. LBS should have 100 electrical operations at rated current. LBS & Earth Switch should have separate apertures for operation.i) One set of 03 nos. ( for 3 phases) dual core Cast Resin CTs for Eachincomer VCBcomplying with IEC:60185 & IS 2705 ( along with latest amendments) , Core -1 - 400-200/1 A , 2.5 VA, Cl 0.5 for metering ; Core-2 - 400-200/1 A, 2.5 VA , 5P10 for Protection.ii) 01 no. of 03 phase Dual Core PT forHT bus ( 11 kV)with protection HRC fuseCore 1- 11kV /√3 / 110V/√3, Cl 0.5s, 50VACore 2- 11kV /√3 / 110V/3, Cl 3P, 50VA(iii) Multifunction Meter:2 Nos. 3 phaseDigital Multifunction Meter6400NGwith Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.for each VCB panel ( 96 mm x 96 mm) , Flush mounted, Class 1 conforming to IEC 62053-22 ( along with latest amendments). 57 Protection Relay: (i) 2 Nos. of Numerical Type Self-powered IDMT Relay(50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Relay should communicate on Modbus RS-485.(ii) Each VCB must have separate Anti Pumping Relay / Antipumping feature through motorization circuit.Fault Passageindicator: The FPI shall facilitate quick detection of faulty section of line. The fault indication may be on the basis of monitoring fault current flow through the device. The FPI should be self-powered and should have internal lithium battery for external indication and setting of FPI in the absence of current.The FPIs shall include: Fault detection - Phase to phase and Phase to earth faults.One potential- free output contacts for hardwiring to RTUs. On this basis, the SCADA/DMS will be able to monitor phase / earth fault condition.Local fault indications - LCD display on FPI front panel along with LED indication on front panel of RMU enclosure.Multiple reset option : End of time delay (Adjustable from 2 to 16 Hrs)Remote reset (Via potential free input contact of FPI)Manual reset (Reset button on front panel of FPI)Automatic reset on current restoration.The characteristics of the FPIs shall include: Phase fault thresholds configurable from at least 100 to 800 A,Earth fault thresholds configurable from at least 20 to 200 AMultiple number of steps for adjusting phase and earth fault thresholds. Fault current duration range configurable from at least 40 ms to 100 ms in 20 ms steps and further 100 ms to 300 ms in 50 ms steps. Variations with respect to these characteristics may be acceptable as long as they prove applicable and provide the same or better flexibility. 58 EARTHING : The cables shall be earthed by an earthing switch with short-circuit making capacity, in compliance with IEC 62271-102 standard. The earthing switch can only be operated when the switch is open. The switch and earthing switch operating mechanism shall have a mechanical endurance of at least 1000 operations. Integrated line side Earth switches shall be provided in each HT Circuit. ( against each VCB)RMU Bushing & Cable Termination: It is preferable to have all bushings accessible from the front of the RMU. Bushings along the sides or the rear of the RMU are not acceptable.For each cable compartment, the bushing shall be at the same height in order to facilitate a possible reversal of the cables. The bushing should be conveniently located for working with cables specified and allow for the termination of these cables: - 630 A M16 bolted connectors for switch-disconnectors and vacuum circuit breakers functions.The profiles of the cable connection bushings shall be in compliance with IEC-60137 standard. Cable clamps:A cable clamp arrangement must be provided for all network cables terminated on the RMU.Provision for Cable Entry: There shall be suitable provsion for Cable entry from bottom through 3 mm thick CRCA steel thick detachable gland plate along with provision for termination of 2 runs of 3 c X 300 Sq mm 11 kV (E ) , XLPE insulated Aluminium Cables (for HT side) and at LT side runs of cables matching with outgoing MCCB current rating.Note: (i) Quotated rates shall be inclusive of foundation for the installation of VCB as per OEM drawing.(ii) The equipment shall be tested by SEIaftersuccessful installtion and report shall be submitted to this office and cost deemed to inclusive in qoated rates 59 M&L for water proof, 3 core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade including PVC conduits properly fixed on steel poles using GI wire for electrical connection of street light fittings, complete all as specified and directed. 60 Supply and fixing junction box having protection dust proof, acid resistant, shock proof, fire retardent self extinguisher for outside installation with knockout entry for cable of size 10 - 25 sqmm andminimum size 295x195x95 mm with terminals, with and includingbrackets for street light pole mounting andone 6A MCB SP complete all as specified and directed. 61 M&L for Advanceencapsulated compound based Chemical earthing CPRI tesed maintenance free , pipein -pipe technology upgraded(Zinc & Alloy coated). , Zinc & Alloy coated (80 -100) microns with pure zinc (99.9%) & Alloy coating (200-250) microns. Earthing system conforming IS 3034. The outer and inner pipe should be 76.2 mm and 41.9 mm dia respectively of3 mtrs long zinc coated with additional special alloy coating 300 mm on top side for additional protection of the terminal . The annular space between the pipes to be filled up with Compactfill (CF) (Crystalline Conductive) mixture which should bemachine pressed in the pipes not disintegrate or collapse when outer pipe corrodes . The inner pipe should be extended with terminals for connectivity.The job includes digging the pitsin any type of hard densesoilof min size 1000 X 1000 X 3050 mm depth taking out excavated soil, lowering/ placing thethe pipe in pipe earth electrode in pit in center ,filling of pure conductolite back filling compound (BFC Conductolite) having excellent moisture retaining capacity in 300 mm around the electrode(minimum 4 bags of 25 KG per pit per unit) or more qty of backfillcompoundas required to fill around the the elctrode in 300 mmin circumfrance of electrode . Contractor has to fill the remaining portion of pit withlow resistivity soil (agriculture soil) free from stones etcs, to be bring from out side defence landas the soil resistivity ofStn is very high and mixed with min 3 Bags of 50 Kg each of Bantonide clay. The BFC should be eco friendly it should not contain envernmently hazardous material/metal having ROHS certification from NABL accredited lab.The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals. The material of earth electrodeshould have good electrical conductivity & anti corrosion property in wide range of soil conditions. The job also include M & L for in PCC(1:3:6) typeC-1 around the FRP cover for support and foundation and colouring the PCC work withdesired colour.completeall as specified and directed. Item Continued as 6.01 62 Note : (i) Design of earth electrode should be of pipein-pipetechnology .(ii) Contractor have to submit literature of earth electrode and get the make approved of GE before procurement.(iii) The earth electrode shall be CPRI tested to withstand short current test for 60kA rms for 1.0 second and 150kA for peak current.(iv) Contarctor has to fill pure back fill compound conductolite all around the earth electrodein 300 mm bore up to full depth of bore.(v) Contractor shall refill the pit with low resistivity soil (agriculature soil ) free fron stone etc and mixed with 06 bags of Bentonite of 25 Kg each to achive the low resistance values. (vi) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection. This Earthing System used for VCB and RMU only. For Solar Power Plant Earthing System is already deemed to be included in quoted rates.(vii) Necessary cost of repair to plinth protection and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 6 x Bags of bentonidedeemed to be included in the item rate.(viii) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work. 63 SAFETY EQUIPMENTSSupply and fixing Rubber hand gloves suitable for 11 KVas per OEM recommendationcomplete all as specified and directed. 64 S&F for glass framed Shock treatment chart both in Hindi & Englishand connected accessoriescomplete all as specified and directed. 65 S&F for dry powder chemical type 4.5 kg fire extinguiser with clamps and connectedaccessories ISI Marked complete all as specified and directed. 66 S&F for single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. as required as per OEM recommendationcomplete all as specified and directed. 67 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. 68 Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, manholes, laying of UG cables/pipes etc. not exceeding 10 Sq.m on plan and getting out in soft/loose or any type of soil complete all as specified and directed. 69 Removing excavated material (soils) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. 70 Returning filling in, soft/looseor any type of soil including spreading leveling watering and ramming complete all as specified and directed. 71 Excavation in post holes (or similar holes) in soft/loose soil each n.exc 0.50 cum, getting out,returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface all as specified & as directed. 72 M&L for RCC M-20, design mix (using 20mm graded crushed stone aggregate), including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 73 M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plugs, bolts, nuts & screws as specified type 410 SP-31, 9.0 meter longinclusive of two coats of aluminium paint over one primer coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified and directed.NOTE : (a) The poles shall confirm to IS - 2713 & each component pipe shall be ISI Marked & confirm to IS - 1161. (b) Necessary earthwork, PCC etc. shall be measured & paid separately under relevant items of work. 74 S & F LED Street lights nominal power 90 Watt, LED of Make Osram; Bridgelux ; Philips; Nicha; Cree; Samsung, LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hourswith IK10 and L70 on including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.(i) If connection.cable from pole Juction box to street light and street light bracket up to 2 mtrs be included and measured in unit rate item, Beyond 2 mtrs of length to be paid seperately under respective items.(ii)At location where street lights/flood light are connected through overhead conductor, connection cable from light fitting to overhead conductor is deemed to be incl in the item rate. (iii) All LED street light/flood lights shall be properly connected with earth dolly provided with fittings and steel poles earth bolt.(iv)All LED lights have replacement warranty of 5 years from the date of completion of the contract accordingly condition 46 of GCC (IAFW-2249) shall be amended to extent mention above. Contractor has to submittwarranty certificate from manufacturer . Payment of light fitting will be released after receipt of 3 year replacement warranty certificate from manufacturer.(v) The LED lights will replaced bythe contractor free of cost in the case of manufacturing defects and Failure due to electrical impact if not connected properly with earth. Hence it is contractor responsibility to connect the light fitting earth wire and shall be grounded properly.(vi) The contractor shall submit the surge protection certificate and Type test certificate LM 79, LM 80 for luminaries from LED manufactutre. 75 M&L for Cement concrete (1:4:8) type D2, (Using 40mm graded crushed stone aggregate) as in foundations of poles and stay, filling and mass concrete complete all as specified and directed. 76 M&L for plain cement concrete (1:3:6), type-C2 (40mm graded crushed stone aggregate) as in foundation, filling and mass-concrete, coping etc for pole foundationwith and including necessary formwork complete all as specified and directed. 77 M&L PCC (1:2:4) type B2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete and copingwith and including necessary formwork complete all as specified and directed. 78 Material & labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick burried directly in ground (Earth pit not less than 4 mtr deep below ground level) with top edge of the plate not less than 3.25 mtrbelow ground level connected to copper strip 20 x 3.15 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation for earth pitin hard dense soil, rocky / disintergate rock, filling charcoal and salt around the plate in layers , filling the pit with low resistivity agriculture soil free from stones, to be bring from out side defence land and mixed with Bentonite , (4 bags of 25 Kg each ), construction ofinspection pit ( earth pit chamber) of brick work of size 600 x 600 x 600 mmwith PCC copping of 1 :1.5: 3, 12.5 mm aggregate A1 with MS sheet 2.8 mm plate cover on frame ofangle iron of size 40 x 40 x 5 mm with , wire mess, funnel, test point, 40 mm dia GI protection pipelightgrade and20 mm GI peforated pipefor wateringetc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately Item Continued as 22.01 79 NOTE :-(i) Contractor shall uselow reisistivity fresh agriculture soil , mixed with 4 x Bags of bentoniteclay of 25 Kg each for refillingthe pit to achive the desired resistance.(ii) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection(iii) Necessary cost of repair to plinth protection as per existing specification and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 3 x Bags of bentonitedeemed to be included in the item rate.(iv) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work.(v) Contractor has to submit test report of earthing after completing the earthing.(vi) Bentonite clay should be Conf to IS 6186: 1986.(vii) The cost ofCopper strip of size 20X3.15 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately.(viii). All the joints in copper strip and connection with Earth Plate to be welded through brazing and in addition by proving brass nut bolt and washer are deemed to be included in the unit rate. (ix) Cost of brazing / welding and nut bolts are deemed to be included in the unit rate. (x) Cost includes removal of excavated soil upto a distance of 100 mtrs. 80 Supply and fixing copper strip of size 20 x 3.15mm as earth continuity conductor or main earthing lead fixed on V typeporcelain insulator, 4 BM, heavy duty ( ceramic bus bar supportinsulator off whitecolour ofsuitable for mounting strip of 20 mm wide x 3.15 min thick) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3.15 mm copper strip brazingto each joints and connected with by providingbrassnut boltsand washer including test point all as specified and directed by Engr in Charge. Note : Insulators shall be provided on every 50 cm. (Minimum 2 x insulators to be provided in every 1 x metre of strip and rate of the same deemed to included in quoated rates) 81 M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as specified and directed. 82 Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and as directed. 83 M&L for GI pipe 100 mm bore, light grade with all fittings and fixtures (ISI Marked), laid in trenches, under road or fixing on wall/ pole /crossing drain /nallah etc. of bore complete all as specified and directed. 84 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 85 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 86 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 87 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 88 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 32 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 89 S&F for 63mm (OD) PP-R Gate valves (brass insert)and connected acessories complete all as specified and as directed. 90 S&F for 32mm (OD) PP-R Gate valves (brass insert) nd connected acessories complete all as specified and as directed. 91 M&L for hard core of gauge not exceeding 63mm with broken stone or boulders, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed. 92 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. 93 S&F for RCC pipes of 600 mm dia, NP-2 laid and jointed complete with collars complete all as specified and directed. 94 S&F for 250mm bore Flue pipes of mild steel sheet, black, in suitable lengths as approved by GE and fixed to walls complete all as specified and directed. 95 M&L for Brickwork with fly ash bricks (modular bricks ), straight or curved on plan exc 6m mean radius, built in cement mortar(1:6) complete all as specified and directed. 96 Material and labour for plastering 15 mm thick (in two coats of 10 mm and 5 mm thick) on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound will be deemed to included in qoated rates. 97 M&L for applying three coats of white wash on newly plastered wall surfaces including preparation of surface complete all as specified and directed. 98 S & F hot rolled low tensile structural steel of grade E165 as per IS 15911: 2010 as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. Wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar works complete all as specified and as directed. 99 S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge. 100 S&F flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 S&F MS screw bolt (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc. 5 cm and n. exc 10 cm long, diameter of neck 5 to 10 mm complete all as specified and directed. 102 Supply and fixinggalvanized steel chain link fence fabric of mesh size as approved , made out of 4 mm nominal dia of mesh wireconforming to IS 2712-2003 and having zinc coating of type heavy as laid down in IS-4826 including line wires/ binding complete all as specified and as directed(A Board of Officers under the orders of GE shall be convened to ascertain the weight per square metre of galvanized steel wire chain link fencing brought at site by the contractor against each lot of materials). 103 S&F 10mm round bars Fe-410-W (Gde-250) quality-A or Fe-290-(Gde-E-165) as in stiffner to hold the chain link fencing fixed with angle iron post inclucinding necessary welding and fixing arrangement at ends complete all as specified and directed . 104 S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steelpins, etc. complete all as specified and directed . 105 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 106 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface not exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 107 Materials and Labour for reinforced cement concrete M-20design mixin columns; pillars; piers; posts; struts etc,complete all as specified and directed. 108 S&F for Mild steel TMT bars 10mm dia and over, conforming to Fe 500 D, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 109 S & F for mild steel TMT bars 6 to 8 mm dia, conforming to Fe 500 D cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, stirup,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 110 M&L for construction of valve chamber with MS sheet cover 3mm thick with angle iron) frame of size 50 x 50 x 6mm and locking arrangements including painting one coat of primer followed by two coats of black sysnthetic paint including excvation and earth work in any type of soil,PCC (1:4:8) type D2 in foundation ,PCC benching 1:2;4 type B-1 ,PCC (1:5:8) block masonry 20 cm thick in cement mortor (1:6),10 mm thick plastering in CM 1:4 ,PCC bed in (1:3:6) and coping 50mm hick in cement concrete 1:2:4 type B1 using 20mm stone aggregate including necessary formwork,paintin one coat of red oxide and two coats of bituminious black paint on all steel surfaces as specified and as directed of sizes 800mm x 800mm x800mm (internnal dimensions) complete all as specified and as directed. 111 Sch A Part-II (Phase-II) 112 Providing Services for Manning and Operation of Solar Power Plant 0.8 MWp near 33 KV receiving stationat Sevoke Mil Station for FIRST YEAR after completion of Ph-I of the subject work with oneskilledcategory Electricianhaving certificate of Surya Mitra from NISE) for twoshifts of 8 hour, one helper (semi-skilled category) in two shift of 8 hrs eachcontinuous operation (including Sunday/Holiday) to maintain sub station in/out side Panels, Invertor, DC junction box, VCB as specified, including daily and weekly check up including cleaning of PV modules complete with suitable cleaning cloths etc , upkeeping the installation operational and in health condition, having own conveyance and communication system like mobile etc. complete, for Solar Power Plant with all minor consumable and expendable items and labour and tools for smooth and efficient operation complete all as specified and directed by Engineer-in-Charge. Make of spare parts / equipments of the Solar Power Plant :- Same as installed in the preceding phase of the work.Repair or replacement ofdefective components or spare parts will be carried out free of cost under DLP and comprehensive Maintenance as per OEM recommendation up to DLP period included in BOQ item No. 1.00. The Contractor may submit his claim for every months on pro-rata basis subject to condition 64 of IAFW-2249 (General Conditions of Contracts)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 17,92,949.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. Item Continued as 56.02 to 56.06 113 NOTES :- In addition to and Manning, Operation and Maintenance of Solar Power Plant, the following works will also be carried out by deputing addl manpower where required, to the entire satisfaction of Engr-in-Charge.(a) Minor repairs and preventive maintenance required to ensure serviceability and efficiency of complete MRS complex including supply of HT 11 KV fuse wire of proper sizeand minor spares such as nut, bolts, spring, lock nut of VCB/OCB as per sample, broom, duster, grass cutting tools, phawara, pick axes for cleaning/grass cutting of complete at Sub Stn Complex. 114 (b) Record of activities such as voltage / current / PF / Energy consumed / temp of transformers, break downs, day to day maintenance of Solar PV Plant etc.(c) The contractor shall ensure that all safety precautions are strictly exercised by the staff employed by him.Adherance to IE rules and statutory rules in vogue must be ensured.The contractor shall be fully responsible for any mishap that occurs due to any fault of the employee or due to non adherance of safety norms.(d) Record of activities such as attendance register, duty roster, pay distribution register of the whole staff employed by the contractor.(e) The electrician staff employed by the contractor shall be ITI holder with four years experience. 115 (g) Security lights within the complex will be operate by the tenderer. (h) The under mentioned tool kitwill be provided at site with person on duty :-(i) Electrician tool kit such as screw driver set, tester, test lamp, cutting plier, insulation tape, fuse wire of required size. (ii) Tongue tester(iii) HT megger(iv) First aid box (v) Shock treatment chart duly framed(vi) 33 and 11 KV Hand gloves(vii) 33 KV discharge rod withcopper chain(viii)) Helmet -02 nos(ix) Suitable Footwear - 02 nos(x) Cotton protective clothing with long sleeves duly embossed with GE Sevoke as directed. The tenderersquoted rates shall be deemed to be include the cost of all above provisions and nothing extra will be paid on any account. 116 (xi) The Bidders shall abide by the latest Labour rules and minimum wages Act. Wagespaid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. (xii) The Bidders is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess et., as applicable and shall be paid to the workmen as per existing Labour rules/ Acts/ regulations and rate quoted shall be deemed to be included for the same.(xiii) Dress Code : The bidders shall provide the workmen with Dark Blue Colour uniform {formal pant & T-shirt} with labels showing/ printed i.e. Name of the firm and designation on front and on the back of the T-shirt along with protective clothing, Industrial safety shoes, protective gears like helmet, safety belt etc..(xiv) Supervision and attending of all incoming & outgoing Solar Power Plant equipment metering equipments & monitoring to loads & other parameters of incomming & outgoing feeders & maintaining log sheet and attendance sheet. 117 INSURANCE: The Bidders shall also insure the workmen employed on the job.The Bidders shall be responsible for all Accidents/Injuries happening to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward incident or non-adherence to safety and IE regulations or fault in maintaining of internal electric supply system or on account of any mishandling/ wrong operation/ lack of knowledge of safety precautions or on account of any circumstances beyond his/ their control, the bidders shall be solely responsible for settling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by Labour commissioner/court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations. 118 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for SECOND YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 18,75,076.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 119 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for THIRD YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 19,61,175.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 120 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FOURTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 20,51,671.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 121 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FIFTHYEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 21,46,848.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 122 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for SIXTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 22,46,564.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 123 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Seventh YEAR after completion of Ph-I.NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 23,51,386.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 124 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but forEight YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 24,61,315.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 125 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Ninth YEAR after completion of Ph-I.NOTE :-(a)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 25,76,917.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 126 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for TENTH YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 27,03,441.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 127 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIRST YEAR after expiry of DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum andcost of item priced upto ₹500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost. Repairs of minor components any other major components are also in the scope and cost of labour for minor / major components is deemed to be included in the quoted rate for this item.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 128 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor SECOND YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted costrepairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 129 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor THIRD YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 130 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor FORTH YEAR after DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 131 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIFTH YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM. (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d) Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 132 Prime Cost Sum. The prime cost to be used as directed by the Accepting Officer vide Condition 1 (v) and 5 of IAFW-2249 (General Condition of Contracts) forming part of the tender documents.(a) Provide a prime cost of Rs.3,00,000.00 forsupply only of spare parts required for comprehensive maintenance after expiry of DLP of Phase-I, through a BOO convened by the CWE. The spares shall procured directly from the OEMs or their aurhorised distributor/dealer as approved by GE.(b) Bidders/Contractors quoted amount shall be inclusive of his overhead and profit and including all taxes and insert amount to cover all. The Bidders/Contractors is to quote lump sum amount under Column 6 covering all the aspects mentioned here in before, representing (%) percentage under Column 9, Above/Below (+ or - denomination) the Prime Cost Sum inserted by MES under Column 5. However, the quoted amount under Column 6 shall not exceed 15% (Fifteen Percentage) of Prime Cost Sum inserted by MES under Column 5. In case, the Bidders/Contractors quoted amount is in excess of 15% of the estimated amount, the same shall be restricted to 15% (Fifteen Percentage) and the amount quoted shall be corrected accordingly to work out the contract sum. Item Continued as 70.01 133 NOTE:-Prime Cost Sum shall be governed in terms of condition 1 (v) and 5 of IAFW-2249 (General Condition of Contract) and to be regularized through Deviation Order. The following procedure shall be adopted to execute the Prime Cost Sum :-(a) Step –I Service Engineer of OEM along with site executive shall visit every month for Preventive and corrective maintenance on all the Solar Power Plant as specified in BOQ herein before, and undertake routine comprehensive maintenance and identify the list of damage / defective spare parts in Solar Power Plant. Service Engineer have to submit report to concerned Engr-in Charge and BOO before undertaking replacement/ repairs, except in case of emergency.(b) Step –II Subsequently BOO will verify the same and submit the finding to the CWE after assembly of board in terms of CA Provision for concurrence.(c) Step –III After concurrence of BOO, the Engr-in-Charge will direct the contractor and the service provider to replace the unserviceable spare parts.(d) Step –IV Serviceability certificate of Solar Power Plant duly signed by the Service Engineer, BOO findings, GST enabled purchase voucher for the replaced spare parts alongwith draft DO details shall be submitted to the GE for placing of DO’s. The advance on account shall be accompanied alongwith the said DO’s for payment.
Contract Date: Mar 17, 2026 Contract Value : 6.86 Crore
Statutory Bodies & Commissions/Committees No of Bidders 6
West Bengal View Result →
46.
Agriculture #9519259 Technical Bid
Tender For Construction Of Divisional Office Building Vellore At Fsd Sevur Tamil Nadu Region (Recall).; 1 Civil ( S.No.1-96) Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared 2 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and for all lift as directed by Engineer-in-Charge. a) All kind of soil. 3 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 4 Supplying and filling in plinth withsand under floors, including watering, ramming,consolidating and dressing complete. 5 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: a) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40mm nominal size derived from natural sources) 6 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 7 Treatment of soil using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With chlorpyriphos/lindane E.c. 20% with 1% concentration 8 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work;usingcoarse aggregate and fine aggregate derived from natural sources,portland pozzolana / ordinary portland /portland Slagcement,admixtures in recommended proportions as per iS: 9103 to accelerate /retard setting of concrete, to improve durability andworkabilitywithout impairing strength; including pumping of concrete to site of laying, curing,carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge;for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 1)concrete of m30 grade withminimum cementcontent of 350 kg /cuma) All works upto plinth level 9 b)All works above plinth level upto floor V level 10 Centering and shuttering including strutting, propping etc. and removal of form for all heights.a) Foundations, footings, bases of columns. etc. for mass concrete 11 b) Lintels, beams, plinth beams, girders, bressumers and cantilevers 12 c) Suspended floors, roofs, landings, balconies and access platform 13 d) Columns, Pillars, Piers, Abutments, Posts and Struts 14 Stairs, (excluding landings) except spiral-staircases 15 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.a) Thermo-Mechanically Treated bars of grade Fe-500D or more 16 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 17 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : a)Cement mortar 1:6 (1 cement : 6 coarse sand) 18 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. a)Cement mortar 1:4 (1 cement :4 coarse sand) 19 12 mm cement plaster a) 1:6(1 cement: 6 fine sand) 20 15 mm cement plaster on rough side of single or half brick wall of mix: a) 1:4 (1 cement: 4 fine sand) 21 20 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) 22 18 mm thick moulded cement mortar band in two coats under layer 12 mm thick with cement mortar 1:5 (1 cement : 5 coarse sand) top layer 6 mm thick with cement mortar 1:4 (1 cement : 4 fine sand). 23 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shades, laid on 20mm thick cement mortar 1:4 (1 cement:4 coarse sand), jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. size of the tile 600x600 mm 24 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved brand & manufacturer, in all colours & shade, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement & matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only, laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size b) Size of Tile 600x600 mm 25 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 26 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. a)Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent 27 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 28 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.a) On steel work 29 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture 30 Polishing in high gloss/matt finish melamine clear polish on wood work in required color/ wooden shade texture with following process in the sequence as detailed below:1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/ grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) 31 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 32 Finishing with Deluxe Multi surface paint system for interiors using Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm 33 Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 34 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 35 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding 36 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 37 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2 mm thick corrugated (2.5” or 4.2” or 6”) or step-down (2” or 3” or 6” ) as specified 38 Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced withgalvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware,SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleevefor fixing frame to finished wall as perIS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof Silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paidseparately.Note:- Structural design proof checked from a Government Engineering Institute,to be provided by the manufacturer for : (i) Siteswith basic wind speed > 45 m/sec as per IS 875 – Part 3(ii)Sites with structure height more than 20m for all wind speeds Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R2 series with frame (40mm & above) x (40mm & above) & sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook (Height upto 1.2 metre). 39 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread offlame of Class Acategorywith property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance indimensions i.edepth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. a)Frame size 50 x 125 mm 40 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimumcompressive strength50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread offlame of Class Acategory with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) a)35 mm thick 41 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood 42 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matchedteak 3 ply veneering with vertical grains or cross bands and face veneers on both faces ofshutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 43 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) On one side only 44 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters. 45 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) 46 Providng & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with: 5.5 mm thick glass panes 47 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure ation & drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge.The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for cupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.Note:- 2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified boratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories (1) Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr (2) Static Water Penetration Test. (50pa to 0pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. (3) Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml (4) Structural Performance Deflection and formation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm (5) Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for ualitative test. Tests to be conducted on site. (6) Onsite Test for Water Leakage for a ssure range 50 kpa to 240 kpa (35psi) upto 2000 mlNote:- 2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified boratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories (1) Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr (2) Static Water Penetration Test. (50pa to 0pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. 48 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. 49 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 50 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). 51 Extra for providing frosted glass panes 4 mm thick (weight not less than 10 kg per sqm) instead of ordinary float glass panes 4 mm thick(weight not less than 10 kg per sqm) in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). 52 Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge.a)200 mm 53 Providing and fixing Godrej Stainless Steel Glass to Glass Round Lock 7780 complete as per direction of Engineer-incharge. 54 Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) 55 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm 56 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and pair of lever handles of approved quality with necessary screws etc. complete. 57 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less thangrade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 58 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizont al level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mmthick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thicksheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. 59 Full ht. 75 mm. thk Solid Partitions/Semi Glazed Partitions with both side 12mm commercial plywood and 1mm thick Laminate & Providing Aluminium frame of size 50x50x1.8 mm thk (finished) comprising of horizontals and verticals at, 600 mm c/c ,vertically and horizontally fixed firmly to walls / floors / RCC roof etc. Alternate vertical members to go upto RCC ceiling and firmly fixed. Providing 8 mm thk. ISI grade plywood of approved make , finished / fixed with 1 mm thick laminate of approved make & shade fixed with adhesive , fixed on both sides of the partition framework. The laminate to be fixed with adhesive on both sides of the partition upto False ceiling level. 60 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of followingoperations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treatingsimilarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved byEngineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer ofplaster and finally finishing the surface with trowel with neat cement slurry and making patternof 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 61 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 62 Providing & applying patterened texture work on extrenal wall with birla or equivalent brand putty on plastered surface as approved by Engineer-in-Charge, 63 Providing and fixing of FRP Security Cabin in Size of 2.5x2.5x2.5m with M.S frame structure and covered by FRP Pannel and FRP Pyramid shape Plane Roof. FRP Door thick - 20mm (6x2) With, ALdrop, Handel, & 3 Nos. SS Ingies.Inside & Outside writing Counter, Size- L-4x W-11Electrical Point- Inside &Outside Bulb Point, 1plug, 3 Switch,Cloth Hanger- 01Nos as per Engineer in Charge. 64 PLUMBING Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : A) W.C. pan with ISI marked white solid plastic seat and lid 65 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board, 510x1040 mm bowl depth 225 mm 66 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : (Size 600x450x200 mm) 67 Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. 68 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings 69 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 70 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 71 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing:Oval shape 450x350mm (outer dimensions) 72 Providing and fixing toilet paper holder : C.P. brass 73 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.100mm dia Sand cast iron S&S as per IS-1729 74 Providing and fixing soil,waste and vent pipes: Centrifugally cast (spun) iron socketed pipe as per IS: 3989. 75mm dia 75 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.100mm dia Hubles centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905. 76 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.75 mm dia Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905. 77 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 78 Providing and fixing Chlorinated Polyvinyl (CPVC) pipes, having thermal stability for hot &cold water supply including all CPVC plain & brass threaded fittingsi/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes &fittings with one steps CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chases and making good the walls etc. 20 mm nominal Inner dia Pipes 79 Providing and fixing Chlorinated Polyvinyl (CPVC) pipes, having thermal stability for hot &cold water supply including all CPVC plain & brass threaded fittingsi/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes &fittings with one steps CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chases and making good the walls etc.25 mm nominal outer dia Pipes 80 Providing and fixing Chlorinated Polyvinyl (CPVC) pipes, having thermal stability for hot &cold water supply including all CPVC plain & brass threaded fittingsi/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes &fittings with one steps CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chases and making good the walls etc. 32 mm nominal outer dia Pipes 81 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. 82 Providing and placing on terrace (at all floor levels) polythylene water storage tank, IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 83 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size ) , including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 84 EXTERNAL INFRASTRUCTUREConstruction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in Charge. a)With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 85 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. 86 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). Size of 100x0.375x0.20 87 Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment). 88 Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) :Screened through sieve of I.S. designation 16 mm 89 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge 90 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). 91 Fine dressing of the ground 92 Providing & laying Selection no. 1 doob grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge 93 Providing and stacking of Delonix regia (Gulmohar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.v 94 Providing and stacking of Plumeria acutifolia of height 120-135 cm. with 2-3 branches in HDPE bag of size 30 cm as per direction of the officer-in-charge. 95 Providing and stacking of Bougainvillea (Variety Butiana, Lady Mary Baring, Mahara,Mohan,Scarlet Queen, Variegated, Glabra Formosa, Peruviana Odissi, Paratha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) of height 30 cm. to 45 cm. with 2-3 branches in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge 96 Washingtonia filifea palm stem ht. 90-105 cm with 6-7 healthy leaves lush green leaves well developed in big size HDPE Bag 97 Electrical ( S.No.97-211) Supplying of PVC/XLPE armoured cable with aluminium conductor 1.1KV Gradeconfirming to IS 7098 (part I)1988 with upto date amendments of the following size at the site of work3 1/2 X 120 Sq.mm 98 3 1/2 X 70 Sq.mm 99 4 X 25 Sq.mm 100 4 X 10 Sq.mm 101 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness 102 150 mm width X 50 mm depth X 1.6 mm thickness 103 Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness 104 150 mm width X 50 mm depth X 1.6 mm thickness 105 Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness 106 150 mm width X 50 mm depth X 1.6 mm thickness 107 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required.100 mm dia 108 Supplying and fixing of light class G.I. pipe of 100 mm dia.(nominal) 3 metres length along the pole for protection of under ground cable as required. 109 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench as required but excluding sand cushioning and protective coveringUpto 35 sq. mm 110 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185sq. mm 111 Up to 35 Sq mm 112 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) 113 Upto 35 sq. mm (clamped with 1mm thick saddle) 114 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as requiredAbove 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) 115 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 116 Upto 35 sq. mm (clamped with 1mm thick saddle) 117 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 120 sq. mm (45mm) 118 3½ X 70 sq. mm (38mm) 119 4 X 25 sq. mm (28mm) 120 4 X 10sq. mm (25mm) 121 Supplying and fixing hot press molded SMC box of size 140x140x95 mm outside with suitable clamps to the wall/pole/truss/GI Pipe, including providing and fixing of 3 way connectors of suitable rating ,providing and fixing 6A C curve MCB, terminating the incoming and out going cables /wires (but with out end termination glands) making connections etc. as required 122 Supplying and fixing of follwing way sueface / recess mounting vertical type , 415 V , TPN MCB distribution board of sheet steel, dust protected , duly painted , inclusive of 200 A tinned copper bus bar , common neutral link , earth bar , for mounting MCBs (but without MCBs and incomer ) as required4 way ( 4 + 12 ) , Double door 123 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator)8 way (4 + 24), Double door 124 6 way (4 + 18), Double door 125 4 way (4 + 12 ), Double door 126 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 127 Triple pole 128 Supplying and fixing following rating, four pole, 415V isolator in the existing MCB DB complete with connection , testing and commissioning etc. as required 40A 129 63 A 130 Providing and fixing following rating and breaking capacity and pole MCCb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel making connections , etc as required100 A, 30 KA, FP MCCB 131 Supplying & fixing suitable size GI box with modular plate and cover in fornt on surface or in recess including providing and fixing 25A modular socketoutlet and 25A modular SP MCB , Ccurve includingconnections , painting etc , as required . 132 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 133 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 134 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 135 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire 136 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 137 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 138 Supply and Fixing suitable size GI box with modular plate and cover in front on surface or in recess, inculing providing and fixing 3pin 5/6 A modular socket outlet and 5/6 modular swith connections etc.as required . 139 Supply and Fixing suitable size GI box with modular plate and cover in front on surface or in recess, inculing providing and fixing 6pin 5/6 A & 15/16 modular socket outlet and 5/6 modular swith connections etc.as required . 140 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch 141 3 pin 5/6 A socket outlet 142 15/16 A switch 143 6 pin 15/16 A socket outlet 144 Telephone socket outlet 145 RJ45 computer socket cat 6 146 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.8 Module (125mm X 125mm) 147 6 Module (200mm X 75mm) 148 1 or 2 Module (75mm X 75mm) 149 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 150 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.1 run of cable 151 2 run of cable 152 3 run of cable 153 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.1 Pair 154 2 Pair 155 Earthing with G.I. earth plate 600 mm X 600 mm X 6mm thick including accessories, and Providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre longetc . With charcoal coke and salt as equired 156 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 157 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess For connections etc. as required. 158 Providing and fixing 6 SWG dia G.I. wire on surface or in recess For loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 159 Earthing with copper earth plate 600 mm X 600 mm X 3mm thick including accessories, and Providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre longetc . With charcoal coke and salt as equired 160 Providing and fixing 4.00 mm dia copper wire on surface or in recess For loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 161 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I tube, having single prong at top, with 85 mm dia 6 mm thick . base plate including holes etc. complete as required. 162 Jointing copper / G.I tape (with another copper / G.I tape, base of the final or any other metallic object ) by riveting / nut bolting / sweating and soldering etc as required 163 Providing and fixing G.I tape 20mm X 3mm thick on parapet or surface of wall For lightning conductor complete as required (For horizontal run) 164 Providing and fixing G.I tape 20mm X 3mm thick on parapet or surface of wall For lightning conductor complete as required(For vertical run) 165 Providing and fixing testing joint , made of 20 mm X 3 mm thick G.I. strip , 125mm long , with 4 Each. of G.I bolts, nuts, chuck nuts and spring washers etc. complete as required. 166 Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required . 167 Supplying, installation, Testing and commissioning of 90W LED Street light fittingmade up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 in the existing streetlight pole with suitable clamps and nut bolts including giving connection etc., at site of work as required 168 Supplying, installation, Testing and commissioning of 36 watt 2X2 LED flat panel recess mounting luminaire with high brightness LED as light source, suitable for Armstrong/Grid ceiling and fixing on ceiling with suitable hanging chains, clamps and nut bolts including giving connection testing etc., at site of work as required 169 Supplying, installation, Testing and commissioning of 12 watt Round surface mounted LED panel light fitting made of pressure die-cast aluminium luminaire and high translucent frosted plastic diffuser and fixing on ceiling with suitable clamps and nut bolts including giving connection etc., at site of work as required. 170 Supplying, installation, Testing and commissioning of 18 watt Round surface mounted LED panel light fitting made of pressure die-cast aluminium luminaire and high translucent frosted plastic diffuser and fixing on ceiling with suitable clamps and nut bolts including giving connection etc., at site of work as required. 171 Supplying, installation, testing andcommissioningof 20W LED T8 tubelight with Al body, PC diffuser and inbuilt driver along with Highly robust box type luminare suitable for single T8 LED tube and fixing on wall/ceiling by using necessary clamps etc., at the site of work as required 172 Supplying, installation, testing and commissioning of 20W LED tube alongwith Industrial Batten of Environmental friendly, long life, corrosion resistant, impact proof, surface mounting IP66 luminaire with PC housing & opal finish cover suitable for single T8 LED tubelight and fixing on wall/truss by using necessary clamps etc. as required 173 Supply and fixing of7W LED surface mounted LED mirror light luminarie complete and fixing on wall by using necessary clamps etc., at the site of work as required 174 Supplying, installation, Testing and commissioning of 24 watt square surface mounted LED panel light fitting made of pressure die-cast aluminium luminaire and high translucent frosted plastic diffuser and fixing on ceiling with suitable clamps and nut bolts including giving connection etc., at site of work as required. 175 Supplying, installation, Testing and commissioning of 40 watt LED 5700K Post top lantern IP65 with high power LEDs as light source and fixing on pole with suitable clamps and nut bolts including giving connection testing etc., at site of work as required 176 Supply and fixing of 10W pressure die cast aluminium housing Bulk Head LED fitting with IP66 protected withPVC unsheathed copper leads from terminals to the fitting and fixing on ceiling with suitable clamps and nut bolts including giving connection etc., at site of work as required. 177 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (DSR Item for BEE 5 star rated Ceiling fan with Brush Less Direct Current (BLDC) motor 178 Supplying and fixing of single phase, 230V,50Hz, 1800 rpm, 200mm dia sweep, 5 blade Exhaust fan with bird screen for protection against birds & Foreign material and fixing on the wall surface including giving connections etc. at site of work as required 179 Supply of 6 mtr high hot dipped galvanised octagonal poles with 130 mm bottom dia and 70 mm top dia made up of 3mm thick HT sheet along with base plate of size 200x200x16 mm thick along with 4 nos of M20x600 mm high J type 8 EN grade foundation bolts along with template to fix the pole to the foundation and supply of 1 mtr long hot dipped galvanised single arm bracket made up of 40NB dia GI pipe suitable to mount on pole having top 70 mm dia for mounting the street light fixture 180 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregrate 40mm nominal size) foundation including excavation and refliing etc. as required 181 Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.1.2 TR 182 2.0 TR 183 2.8 TR 184 Supply, Installation, Testing and Commissioning of 1.5 Ton/4500 Kcal/hr, 5 Star Rating Inverter technology High wall split type Air Conditioner with minimum of 3 metre length of copper Refrigerant piping with insulation and electrical cable complete with indoor unit (IDU), Outdoor unit (ODU) suitable For 230V +10% of 50 Hz, single phase AC supply and Fixing on the wall surface including giving connections etc. at site of work as required 185 Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. 186 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required19 mm dia (OD) (Hard drawn) with tube thickness 1.2mm with 19mm thick insulation 187 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation 188 Supply and fixing of FP sheet enclosure on surface/recess along with 63A FP C curve MCB complete with connections, testing and commissioning etc. as required 189 Design, Fabrication,Supplying, Installation, Testing and commissioning of Dust and vermin proof Cubicle type LT panel boardsuitable For 3 Phase,415V,50 Hz 4 Wire AC Supply System fabricated in compartmentalized System made out of 14 SWG CRCA Sheet Steel and painted with powder coating in approved shade and comprising of the following:Complete with aluminium busbars ofadequate capacity For Phases & neutral (min. of 250A), Suitable M.S Angle Base Frame, cable alley, interconnections control wiring, including incoming and outgoing cables connections etc as required at site of work and as directed by the Engineer in charge. 190 Design, Fabrication, Supplying, Installation, Testing and commissioning of 315A near by control box with 4 pole 315 A MCCB switch with front handleDust and vermin proof Cubicle type LT panel boardsuitable for 3 Phase,415V,50 Hz 4 Wire AC Supply System fabricated in compartmentalized System made out of 14 SWG CRCA Sheet Steel and painted with powder coating in approved shade and comprising of the following:Complete with aluminium busbars ofadequate capacity for Phases & neutral (min. of 250 A), Suitable M.S Angle Base Frame, cable alley, interconnections control wiring, including incoming and outgoing cables connections etc as required at site of work and as directed by the Engineer in charge 191 Design, Fabrication, Supply, installation, testing and commissioning of 30KVAR Automatic power factor correction panel (APFC) with 6steps of capacitor switching cubicle type, free standing, Powder coated, 14 SWG CRCA sheet steel,enclosed separate compartment For each capacitor, front operated, indoor type dust and vermin proof, hinged, lockable doors, electrolytic grade aluminium bus bars, with SMC /DMC insulator supports, Digital volt meter, Ammeter with selector switch, 6 stage Digital Automatic power factor correction,( APFC ), Auto / Manual selector switch, cluster LED typeindicators, in the incomer,complete with electrolytic grade aluminium bus bars. capacStart, Stop, push buttons, internal wiring, colour coding, ferrules, cable gland plates, Aluminium earth bus For the entire length of the panel with bonding to earth and painting,Panel mounting MS Channels, fasteners, etc., including all associated control wiring and interlocking circuitry, MV panel sensing CT interconnecting wiring etc., complete 192 Supply, Erection, testing and commisioning of 82.5KVA/66 KW Diesel Generating Set (as per the latest CPCB IV+ norms) comprising of Water Cooled, 4 cylinder Diesel engine developing minimum of 102 BHP with electric start compression ignition 4 stroke designed to run continuously at at 1500 RPM. Coupled to Alternator rated at 1500 rpm, 415 Volts, 0.8 power factor, 50 Hz, three phase supply, self-excited and self-regulated, brushless, floor mounted with ball or bearings on end shields and fuel Tank of minimum 150 Ltrs capacity with Standard Control Panel with Breaker, Batteries and Acoustic Enclosure including Transportation, loading-Unloading, UG cable laying from generator to panel, earth strips connections etc., at the site of work as required (Model should have minimum 2 year warranty) 193 Supply, Installation, Testing and Commissioning of 15kVA DOUBLE CONVERSION 3 phase input,3 phase output True Sinewave ONLINE UPS with 0.99 power factor including stand along with supply and erection of 12V/26AH SMF Batteries (30mis back up) of 30 nos.including providing necessary connections etc. complete as required 194 Supplying, fixing and testing of CO2 fire extinguisher of 4.5 kg capacity with hose and horn confirming to relevant ISI specification including fixing on suitable wall mount bracket/ clamp/ hook and nuts,bolts etc., at the site of work as required. 195 Supplying, fixing and testing of ABC Fire Extinguishers Filled with Mono Ammonium Phosphate Dry Powder of 10 kg capacity suitable For all Types of Fires confirming to relevant ISI specification including fixing on suitable wall mount bracket/ clamp/ hook and nuts,bolts etc., at the site of work as required. 196 Supplying, fixing and testing of ABC Fire Extinguishers Filled with Mono Ammonium Phosphate Dry Powder of 6 kg capacity suitable For all Types of Fires confirming to relevant ISI specification including fixing on suitable wall mount bracket/ clamp/ hook and nuts,bolts etc., at the site of work as required. 197 Supplying and fixing of MS angle fire bucket stand with 03 Each fire buckets of 10 litre capacity, at the site of work as required. 198 Supplying, installation, testing and commissioning ofsmoke detection system with minimum of 36 Each conventional type photo-electric smoke detectors, 2x1.5 sq.mm fire resistant armoured cable(red colour), 6 Each Manual Call points, 6 Each Hooters complete with 2 zone fire alarm panel etc at site of work as required 199 Supply, Installation, Testing and commissioning of 16 channel 4 SATA NVR, with 4T Hard Disk Drive 1 Each, New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected,Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output HDMI1 / VGA1 outputs provided HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface For HDD connection, Support upto 10TB capacity For each HDD, Smart search For efficient playback. and smart playback to improve the playback efficiency, Supports VCA search For fire/ship/temperature /temperature difference detection triggered video files, POS inFormation overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access Hik-Connect For easy network management, 2 Gigabit Ethernet network interfaces 200 Supply ,Testing and Commissioning of 4MP Infra Red Dom Camera and fixing the same on wall/ceiling including providing necessary connections etc. complete as required 201 Supply of 8MP, Internet Protocol fixed BULLET CAMERA with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behaviour analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse 202 Supply, Installation, Testing and Commissioning of 55 smart LED TV with following specifications a) Full HD 1920 x1080 (4K monitor) b) IPS panel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3Each m) USB -3Each n) Built in LAN o) Magic remotep) Dimension 1242 x 724 x 55.1min(37) 203 Supply, laying and termination of high quality Un- Armoured Optical Fiber (48 Fibers) along with the all accessories connectors, switches etc complete as required 204 Supply, fixing and termination of high quality rack mounted type patch panel with one number of 24 port switch, fixing frames, links and interconnections, necessary accessories etc., all complete as per specifications, drawings and / or as directed by the Engineer 205 Supply, fixing and termination of high quality floor mounted type 24U floor mountable powder coated Rack with 3x5A Power Manager, 1 position fan, min 1 nos of shelf, Front Glass double door with Lock & key with suitable network port switch, fixing frames, links and interconnections, necessary accessories etc., all complete as per specifications, drawings and / or as directed by the Engineer in charge 206 Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with followingcomponents complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modulesused in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust thevoltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugsand other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. 207 Supply, Erection, Testing and Commissioning of new 160 kVA, 11kV/433V, 3-Phase, 50 Hz, ONAN Cooled, Copper wound Transformer with Energy Efficient level-I, Dyn11 vector group, first fill of oil, Bushing on HT side & Cable box on LT side, off circuit tappings of +5% to -10% in steps of 2.5% with standard fittings confirming to IS 1180, including transportation of the machine from OEM factory to site, mechanized mounting of transformer in the DT structure, providing necessary cable end terminations (LV side), connection of 4 SWG copper down conductor (HV side), body and neutral earth connections, insulation resistance testing and certification of the same etc. as required 208 Providing new service connection to the Divisional Office building by preparation of drawings, coordinating with EB, deposit amount/ statutory charges to be paid to EB for supply and fixing of poles/DT structures, overhead ACSR conductors, associated accessories, including any additional works as per the instruction of EB/FCI engineer-incharge etc. as required. (Deposit Amount/Statutory Fees will be paid by FCI as per actual only) 209 Supplying and drawing of Multicore Round PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts, conForming to IS: 694in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm 210 Supply,erection and testing & commisioning of 2HP submersible pumpset in theOpen borewell of capacity of 4800 LPH @ 265Ft, max. total head of 280 Ft pumps fitted with bronze impellers and having delivery size of 40mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge. 211 Supply of 2m x 1m x 3mm thick corrugated rubber mat as required conforming to relevant ISI specification suitable for electrical application
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 11
47.
Heavy Industries and Public Enterprises #9514339 Technical Bid
Tender For Providing Facade Light At The Entrance Gate No. 1 And 2 Of Ia. Site-4 Sahiababad Ghaziabad. - Supply, Installation, Testing and Commissioning of RGBW LED integral linear grazer of 1m length made of extruded aluminium with die cast aluminium end cap, powder-coated finish, system wattage 50W with SDCM ≤4with all channel ON and Operating temperature -40 to 50 Degree C. Luminaire should be capable of producing dynamic color changing light by DMX/Ethernet based control. Luminaire shuld have a choice of architectural floodlighting optics with asymmetric beam angles of 15°-18°, 30°-40° and 20-25° x 35-40°. Luminaire should be capable of operating at line voltage without any separate power supply from 140- 270 V AC. Lifeclass should be at least 50,000 burning hours at L70@35deg C. Lens should be anti ageing and anti-UV high optical efficiency PMMA lenses covered with clear tempered glass. Luminaire should comply IP66. Luminaire and DMX controller should be of same make to avoid any integration issue after sales service. 2 Supply, Installation, Testing and Commissioning of RGBW LED integral floodlight luminaire with Die-cast aluminium, powder-coated finish, system wattage in the range of 50Wattwith SDCM ≤4 with all channel ON and Operating temperature .-40 to 50 Degree C Luminaire should be capable of producing dynamic color changing light by DMX/Ethernet based control. Luminaire should have a choice of architectural floodlighting optics with beam angles of 3-5° 8-10° ,15-20° and 30-40°. Luminaire should be capable of operating at line voltage without any separate power supply from 140- 270 V AC. Lifeclass should be at least 50,000 burning hours at L70@35deg C. Lens should be anti ageing and anti-UV high optical efficiency PMMA lenses covered with clear tempered glass. Luminaire should comply IP66. .Luminaire and DMX controller should be of same make to avoid any integration issue after sales service. 3 Supply of Content Program Controller with Perfect fit for small and medium size applications ,Supports DMX512, Supports up to 8 DMX universes, Output signal is DMX (no need for sub-controllers), Can amplify the DMX signal in cascaded connection, LCD screen display and remote control, SD card slot to store scene and automatically play then when turned on, Supports automatic playback scheduling, with Al housing,Memory Card Capacity Max 32gb. Temperature Range -30°C to 50°C, IP20. Fixture shall be complaint with CE, CB, RoHS. 4 SITC and fixing of RDM-6 Wall DMX Splitter & Booster is a 6-output DMX/RDM splitter with DMX/RDM, pass-through supporting bi-directional communications Input power DC 12-24V input, 100-240V, 24VDC plug-in power adaptor included power consumption 4.5W max, housing made of polycarbonate, surface mount or DIN-rail mountable, operation temperature 10C- +35C, output six 3-pin terminal socket, connection two piece compression screw terminal, protection Rating IP20, Interior application, Certification CE, BIS. 5 Planning, Designing, Programming of all the light fixtures with integration into controller and making multiple programming in total of 5 different occasion. Synchronizing all fixtures into one. 6 Providing and fixing of exterior signage to be fixed on Top with help of MS frame, signage to be made with help of 3mm acryclic 040 in cut of lazer to be inserted 3 mm ACP(machine colour base ) with router cut. The signage shall illuminated with Modulus and power supply . Make of Modulus and power supply atleast 2 years gurantee complete in all respect.( size 1.40*2.80 mtr) 7 Supply installation commissioning of following sizes of power and data cable as mentioned 3 x 2.5 sqmm Cu unarmored multistrand 8 Supply installation commissioning of following sizes of power and data cable as mentioned 3 x 4 sqmm Cu unarmored multistrand 9 Supply installation commissioning of following sizes of power and data cable as mentioned 5 x 6 sqmm Cu unarmored multistrand 10 Supply installation commissioning of following sizes of power and data cable as mentioned 3 x 35 sqmm Al armoured 11 Supply installation commissioning of following sizes of power and data cable as mentioned Data cable Cat 6 12 Supply, installation, testing and commissioning of PVC Pipe of size 20 mm as per requirement for cable layingand its protection. 13 Supply, installation, testing and commissioning of PVC Pipe of size 40 mm mm as per requirement for cable layingand its protection. 14 Supply, installation, testing and commissioning of Cable termination with glands and lugs in the electrical panel with all necessary accessories. 15 Supply, installation, testing and commissioning of IP 67 rated Boxes with connectors and other accessories for use in all joints of power data cables. 16 Supply, installation, testing and commissioning of Electrical panel with servo stabilizer 2KVA 17 Monkey Protection casing SS grade as per fixture size and dimensions 18 Supply, installation, testing and commissioning of Chemical Earthing for panel. 19 Operation, Maintenance, cleaning, regular upkeep for (1+2) years of the entire system of Gate no 3 20 S/F of 25A SPN capacity of automatic street light cubicle control panel painted with anticorrosive alkali an acid proof paint consisting of digital time switch TSO 100 series with contractors, HRC fuses/MCB isolating switch metering instrument & instrument bos with CTs etc Complete in all respects or as per technical specification approved by Enginner-in charge. 21 Supply and laying of 16 sq.mm 2 core aluminum conductor PVC insulated, un armoured, served, double sheathed cable 1100 V grade pole to pole as per per Job No. ED-II(39)dt.0106.2022. (Havells/Polycab/Grandley/Glostar or equel brand as per technical specification aaproved by engineer in charge. 22 Supply and laying of 25 sq.mm 3.5 core aluminum conductor PVC insulated, armoured, served, sheathed cable 1100 V grade in existing DWC HDPE/MS/GI/Surface etc as UPPWD Sch Item No. 501(i) & 507 (Havells/Polycab/Grandley or equel brand as per technical specification aaproved by engineer in charge. 23 Supply & Laying of63 mm HDPE pipe ISI marked along with all accessories like socket, bend, couple etc. confirming to IS 14930 Part II complete with fitting and cutting, jointing etc direct in ground (750-1000mm below ground level) including excavation and refilling the trench. including cost of material, labour and T&P as per technical specification aaproved by engineer in charge. 24 Supply & fixing of brass nickle plated compression gland for 25 sq. mm 3.5 core cable PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect as per technical specification aaproved by engineer in charge. 25 Supply & fixing of plan or pin type copper tin plated socket/Lug to 25 sq. mm 3.5 core cable leads,insulationt tape and making connection etc. complete in all in respect as per direction of Engineer in charge as per technical specification aaproved by engineer in charge. 26 Supply & fixing of plan or pin type copper tin plated socket/Lug to 16 sq. mm 4 core cable leads, insulationt tape and making connection etc. complete in all in respect as per direction of Engineer in charge as per technical specification aaproved by engineer in charge. 27 S/B of 40 mm dia x 4.5 mtr. long G.I. pipe vertically for earthing having 12 mm dia. Holes spaced 75 mm apart drilled upto 2 mtr. from the bottom, complete with earthing lead of no.6 to 8 SWG GI wire in G.I.pipe upto apronupto switch board 30 cm square box with hinged cover masonry enclosure. Funnel of top, alternate layers of charcoal and salt at least 150 mm thick around etc. as per direction E/I complete in all respects as per technical specification aaproved by engineer in charge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Uttar Pradesh View Result →
48.
Public Administrative Department #9503874 AOC
Tender For Construction Of A Marriage Hall In Kukargaon Village Of Chirgaon Block. - Clearing jungle including up rooting of trunk vegetation grass bush wood trees and sapling of girth upto 30cm. Measured at a height of 1 meter above ground level and removal of rubbish upto a distance of 50m. outside the periphery of area cleared as per SI.No. 2.31 2 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil as per SI.No. 2.8.1 3 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 300 mm dia piles. DSR-20.3.1 4 Vertical load testing of piles in accordance with IS 2911 (Part IV) includinginstallation of loading platform by Kentledge method and preparation of pilehead or construction of test cap and dismantling of test cap after test etc.complete as per specification & the direction of Engineer in-charge.Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing.Single pile upto 50 tonne Safe capacity Initial test (Test Load 2.5 times the Safe capacity) DSR-20.6.1.1 5 Routine test (Test Load 1.5 times the Safe capacity) DSR-20.6.1.2 6 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration as per SI.No. 2.35.3.1 7 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. as per SI.No. 2.25 (a) 8 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. as per SI no 2.27 9 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-lll) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) As per SI no. 4.1.8 10 Brick work with common burnt clay (non modular) bricks of class -150in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) as per SI No- 6.1.1 11 Brick work with common burnt clay (non modular) bricks of class -150in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) as per SI No- 6.1.2 12 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing in 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size): as per SI No. 4.2.3 13 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:All works upto plinth level. Concrete of M25 grade with minimum cement content of 330 kg /cum. DSR-5.33.1.1 14 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: All works above Plinth Lvl. Concrete of M25 grade with minimum cement content of 330 kg /cum. DSR-5.33.2.1 15 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete in Thermo-Mechanically Treated bars of grade Fe-500D or more. As per SI. No.- 5.22.6 16 Add for using extra cement in the items of design mix over and above the specified cement content therein. As per SI. No.- 5.35 17 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. as per SI-4.13 18 Brick work with common burnt clay bricks of M-150 Class in super structure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:4 (1 cement : 4 coarse sand ) as per SI no 6.13.2 19 Brick work with common burnt clay bricks of M-150 Class in super structure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:6 ( 1 cement : 6 coarse sand ) as per SI no 6.4.2 20 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings,glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment). as per SI no. 10.11.1 21 Steel work welded in built up sections / framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc.In grantings, frames, guard bar, ladder, railing, brackets, gates and similar works as per SI no. 10.25.2 22 Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strikeplate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B- Fixing with adjustable lugs with split end tail to each jamb. as per 10.14.1.1 23 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes. As per SI no. 10.16.3 24 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part 1) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary. Extra for cutting rebate in flush door shutters as per SI No- 9.20.1 25 Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge Window Chaukhatas per SI-14.2.2 26 Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-ChargeVent. Chaukhatas per SI- 14.2.3 27 Providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory, all complete with 4.0 mm thick glass panes. As per IS 10.30.1 28 12 mm thick cement plaster of mix 1:6 ( 1 cement & 6 course sand ) as per IS 13.4.2 29 12 mm thick cement plaster of mix 1:6 ( 1 cement & 6 course sand ) as per IS 13.4.2 30 15 mm thick cement plaster of mix 1:4 ( 1 cement & 4 coarse sand ) as per IS 13.5.1 31 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. As per SI No.-5.30 32 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone ) finished with floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. 40 mm thick floor 20 mm nominal size stone aggregate. As SI No. 11.3.1 33 Providing & laying rectified glazed ceramic floor tiles of size 300x300 mm or more ( thickness to be specified by the manufacturer), of 1st quality confirming to IS:15622, of approved make, in colours white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grounting the joints with white cement and matching pigmrnts etc., complete as per SI no. 11.39 34 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. as per SI no. 11.37 A 35 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm as per SI no 11.41.2 36 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to 1.8. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc complete. Size of Tile 600x600 mm as per SI no 11.46.2 37 Providingandfixing18mmthickGranite(gangsaw cut) mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, windowsills,faciasandsimilarlocations,ofrequired size,approvedshade,colourandtexturelaidover20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand),jointstreatedwith whitecement,mixedwith matching pigment, epoxy touch ups, including rubbing,curing,mouldingandpolishingtoedgesto givehighglossfinishetc.completeatalllevels. Granite stone slab of colour black, Cherry/Ruby red. (Slab area above 0.50 Sq.M.) As per SI no- 8.2.2.2 38 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture as per Sl no. -13.62.1 39 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre as per Sl no. -13.41.1 40 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) as per Sl no. -13.47.1 41 Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer,over the plasterd wall surface even and smooth surface as per Sl no. -13.80 42 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: 43 (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”: With average thickness of 120 mm and minimum thickness at khurra as 65 mm. as per SI no. -22.7.1Providing & fixing oxidized M.S. sliding door bolts ISI marked with nuts and screws etc 44 Providing & fixing oxidized M.S. tower bolts ISI marked with nuts and screws etc complete (300mm x 10mm).(a) 250mm x 10mm As per SI-9.63.1 45 Providing & fixing oxidized M.S. tower bolts ISI marked with nuts and screws etc complete (300mm x 10mm).(b) 200mm x 10mm As per SI-9.63.2 46 Providing & fixing oxidized M.S. Door Handle ISI marked with nuts and screws etc complete (125mm). As per SI-9.66.1 47 Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. As per SI No- 14.34 48 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter. As per SI- 12.41.2 49 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. As per SI-12.22 50 Centering and shuttering including stutting, propping etc. and removal of form.(i) Beam /Band as per SI- 5.9.5 51 Centering and shuttering including stutting, propping etc. and removal of form.(ii) Column as per SI- 5.9.6 52 Centering and shuttering including stutting, propping etc. and removal of form.(iii) Foundation as per SI- 5.9.1 53 Centering and shuttering including stutting, propping etc. and removal of form.(iv) Slab as per SI- 5.9.3 54 Providing and fixing GI Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing ‘C’ wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with the help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c.Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with the help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with :GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of GI sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation. As per 12.54.2 55 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/m². As per SI-12.1.1 56 Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.80 mm thick with zinc coating not less than 275 gm/m². As per SI-12.4.1 57 Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. 0.80 mm thick with zinc coating not less than 275 gm/m². As per SI-12.7.1 58 SANITARY FIXTURES & ACCESSORIES : IProviding and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required European type W.C. pan with white plastic seat and lid. 59 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require a)White Vitreous China Flat back wash basin size 550 x400 mm with single 15 mm C.P. brass pillar tap. 60 Providing and fixingStainless Steel AISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm 61 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Semi rigid pipe a) 32mm dia 62 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Semi rigid pipe b) 40mm dia 63 Supplying & Fixing ofCP soap tray fixed to the wallwith PVC rubber plug with CP brass screws. 64 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in -charge. 65 SOIL WASTE & VENT PIPES AND FITTINGS - IIProviding, fixing, jointing and testing in position of ISI marked PVC pipesfor soil, waste, and vent including all neccessary specials and fittings i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, cowels, clamps, hangers, rubber rings, clean outs etc. fixing at wall / ceiling / floor level supported by clamp & hangers etc.inside duct / suspended from floor under false ceilingfor proper completion of the work. The rubber ring shall confirm to IS:5382. (Make : Supreme / Finolex / Prince) (Pipe support : Intellotech / Easyflex / Chilly)The Pipes will be supportedby either rubber lined G.I. U strap clampson 50x50x5 mm MS slotted angle duly painted (for a group of pipes) or G.I. rubber lined split clamp (for independent pipes). The The cost will include all support arrangements. The work includes cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site.110mm diaCh-23 Item-43, Kannauj 66 Providing, fixing, jointing and testing in position of ISI marked PVC pipesfor soil, waste, and vent including all neccessary specials and fittings i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, cowels, clamps, hangers, rubber rings, clean outs etc. fixing at wall / ceiling / floor level supported by clamp & hangers etc.inside duct / suspended from floor under false ceilingfor proper completion of the work. The rubber ring shall confirm to IS:5382. (Make : Supreme / Finolex / Prince) (Pipe support : Intellotech / Easyflex / Chilly)The Pipes will be supportedby either rubber lined G.I. U strap clampson 50x50x5 mm MS slotted angle duly painted (for a group of pipes) or G.I. rubber lined split clamp (for independent pipes). The The cost will include all support arrangements. The work includes cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site.75mm dia 67 WATER SUPPLY PIPES AND FITTINGS - IIIProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.(internal work) Exposed on wall25mm dia nominal dia pipes 68 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.(internal work)32mm dia nominal dia pipes 69 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.(internal work) 40mm dia nominal dia pipes 70 Concealed work, including cutting chases and making good the walls 15mm dia nominal dia pipes 71 Concealed work, including cutting chases and making good the walls 15mm dia nominal dia pipes 20mm dia nominal dia pipes 72 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. a) 15mm nominal bore 73 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931a) 15mm nominal bore 74 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. a) 15mm nominal bore 75 Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 a) 15mm nominal bore 76 Providing and fixing gun metal gate valve with wheel of approved quality. a) 25mm dia nominal bore 77 Providing and fixing gun metal gate valve with wheel of approved quality. 32mm dia nominal bore 78 Providing and fixing gun metal gate valve with wheel of approved quality. 40mm dia nominal bore 79 Providing and fixing brass stop cock of approved quality. a) 15 mm nominal bore 80 Providing and fixing brass stop cock of approved qualityb) 20 mm nominal bore 81 Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 82 SCHEDULE OF QUANTITIES FOR INTERNAL & EXTERNAL SEWERAGE SYSTEM - IVExcavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m.a) Pipes 80mm to 300mm diameter. 83 Providing, laying and joining glazed stone ware pipes grade Awith stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 150mm diameter 84 Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. 150mm diameterS.W. Pipe 85 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of .class designation 7.5 86 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75(i) For Sewer Line 87 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.From 0.00 mt to 1.50 mt 88 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.From 1.50mt to 3.0 mt 89 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.From 3.00mt to 4.50 mt 90 Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost of form- work, in foundation and floors. 91 Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete, excluding cost of form- work, in foundation and floors. 92 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: All works above Plinth Lvl. Concrete of M25 grade with minimum cement content of 330 kg /cum. DSR-5.33.2.1 93 Brick work with common burnt clay (non modular) bricks of class -150in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand). 94 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete in Thermo-Mechanically Treated bars of grade Fe-500D or more. 95 Add for using extra cement in the items of design mix over and above the specified cement content therein. As per SI. No.- 5.35 96 12 mm cement plaster in single coat on rough side of single or half brick wall finished with a floating coat of neat cement. (1) 1 cement : 3 Coarse sand 97 Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor). 98 Supply & Laying of 40 mm gauge over burnt brick ballast including all materials, labour and T&P etc. for proper completion of the work. 99 Providing and fixing soil, waste and vent pipes : 75mm diameter : Sand cast iron S&S pipe as per IS: 3989 100 Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:(With 20x20mm square bar) 101 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality Circular shape 450 mm internal diameter 102 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality Circular shape 500 mm internal diameter 103 Centering & shuttering including strutting, propping etc. and removal of form for slab 104 Supply and Fixing of Fire Extinguisher ABC Type 6.0 kg. Capacity ( ISI Market IS : 15683 & TAC approved ) complete with initial charge and wall bracket, along with supply of all materials and labour for propercompletion(Firiecon/LifeGurd/Firefit/Excell) 105 Supply and Fixing of CO2 Type Fire extinguisher 6.5 kg capacity( ISI Market IS : 2878 & TAC approved ) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of works (Firiecon/LifeGurd/Firefit/Excell) 106 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. From 0.00 mt to 1.50 mt 107 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.1.50mt to 3.0 mt 108 Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost of form- work, in foundation and floors. 109 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: All works above Plinth Lvl. Concrete of M25 grade with minimum cement content of 330 kg /cum. DSR-5.33.2.1 110 Brick work with common burnt clay (non modular) bricks of class -150in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand). 111 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete in Thermo-Mechanically Treated bars of grade Fe-500D or more. 112 Add for using extra cement in the items of design mix over and above the specified cement content therein. As per SI. No.- 5.35 113 15 mm cement plaster in single coat on rough side of single or half brick wall finished with a floating coat of neat cement. (1) 1 cement : 4 Coarse sand 114 Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor). 115 Supply & Laying of 40 mm gauge over burnt brick ballast including all materials, labour and T&P etc. for proper completion of the work. 116 Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:(With 20x20mm square bar) 117 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality Circular shape 500 mm internal diameter 118 Centering & shuttering including strutting, propping etc. and removal of form for slab 119 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineriesequired for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. Drilling of 300mm dia bore hole manually. 120 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia 121 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 122 DRAINAGE NETWORKExcavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. up to 1.50 m depth Pipes 80 mm to 300 mmdiameter 123 Providing and laying NonpressureNP2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand) includingtestingof joints etc. complete. 150 mm.dia. RCCPipes 124 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150 mm. dia. 125 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of .class designation 7.5 126 Earth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 50 meter and including filling, watering and ramming of excavated earth disposal of surplus earth as directed by the E-i-c up to a distance of 50 mtr from the foundation trenches. DSR-2.8.1 127 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of E-i-c. With material conforming to Grade-II (Size range 53 mm to 0.075 mm) having CBR Value-25 DSR- 16.78.2 128 Supplying and stacking at site 63 mm to 45 mm size stone aggregate. DSR- 16.3.2 129 Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density. DSR- 16.4 130 M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work.DSR-6.1.1 131 Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete including supply of all materials, labour and T&P etc. required for proper completion of the works. DSR-4.1.3 132 Providing and laying design mix cement concrete of M-30 grade, in roads/taxi tracks/runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. Cement concrete prepared with batch mixing machine DSR-16.43.1 133 Providing and laying in position cement concrete of specified grade - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-lll) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)[DSR- 4.1.8] 134 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60 mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.[DSR-16.91.1] 135 (A) Boring 150 dia bore hole including labuar, T & P etc. required for proper compelete of the work. 136 (B) Lowring 110 dia mm PVC pipe in bore hole including labuar, T & P etc. rquire for proper compelete ofthe work. 137 (C) Providing and fixing 110 mm dia PVC pipe 6KG/cm2 138 (D) Shrounding and packing graded coarse sand in between bore wall & the Strainer including supply of coarse sand, labour, T&P ete required for proper compeletion of work. 139 (E) Providing and fixing G.I. pipe 32mm dia Nominal bore compelete with GI Fitting 140 (F) Submersible pump Kirlosker / Crompton or equivalent 2.0 HP I.S.I. marked. 141 (I) Single fase stater for submersible of I.S.I marked. 142 (J) 2.5 mm Sq cable for submersible moter pump. 143 (K) 4 Inch dia MS clamp made with 32*5 mm flate iron with nut & bolt 144 (L) 100 mm dia & P.V.C endcap. 145 (M) Solution for jointing P.V.C pipe. 250 gram 146 (N) 32 mm C.P.V.C pipe 147 (O) Developing of bore well by over pumping and back washing till the discharge is free from turbidity not greater then 20 p.p.m. after 20 minutes of starting of pump including hiring charges of pump set, labours, T&P complete required of completion of work. 148 (P) Nylon cloth for strainer including plastic rope, cutting holes in PVC pipe etc complete.
Contract Date: Mar 06, 2026 Contract Value : 88.85 Lakh
Government Departments No of Bidders 2
Uttar Pradesh View Result →
49.
Housing Urban and Rular Development #9503110 AOC
Tender For Proposed Rejuvenation And Development Of Tourist Facilities At Between Assi Ghat To Dashaswamedh Ghat At Varanasi (U.P.) - Proposed Rejuvenation and Development of Tourist Facilities at Between Assi Ghat to Dashaswamedh Ghat at Varanasi (U.P.) 2 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed as directed by Engineer-in- charge.All kinds of soil 3 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming & watering, lead up to 50 m and lift upto 1.5 m. 4 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 5 Carriage of Earth by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 6 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. - Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 7 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 8 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 9 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 10 Demolishing stone pitching in floors, slopes, etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 11 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 12 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete 13 Carriage of Rubbish by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 14 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. 15 Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete. 16 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. 17 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 18 Same as item 16 but With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 19 Carriage of Soling Stone by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 20 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 21 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 22 1:3:6 (1 Cement : 3 coarse sand (zone-Ill) derived from natural sources :6 graded stoneaggregate 40 mm nominal size derived from natural sources) 23 Carriage of Stone Aggregate 40mm nominal size and above by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 24 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 25 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.Concrete of M25 grade with minimum cement content of 330 kg /cum.All works upto plinth level 26 Concrete of M25 grade with minimum cement content of 330 kg /cum.All works above plinth level upto floor V level. 27 Carriage of Sand, Stone Aggregate below 40mm by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 28 Add for using extra cement in the items of design mix over and above the specified cement content therein. 29 Carriage of Cement by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 30 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator, vacuum dewatering process and finally finished by floating, brooming with wire brush etc. All complete including shutting, channel, etc. as per specifications and directions of Engineer-in-charge. 31 Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) :400 mm dia piles 32 Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) :500 mm dia piles 33 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/ Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing.Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge.Single pile upto 50 tonne Safe capacity Initial test (Test Load 2.5 times the Safe capacity). 34 Routine test (Test Load 1.5 times the Safe capacity) 35 Single pile above 50 tonne and upto 100 tonne Safe capacity Initial test (Test Load 2.5 times the Safe capacity) 36 Routine test (Test Load 1.5 times the Safe capacity) 37 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete for all lift and level.Thermo-Mechanically Treated bars (Fe500d) 38 Carriage of Steel by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 39 Centering and shuttering including strutting propping etc, and removal of form for : Foundations, footings, bases of columns etc., for mass concrete. 40 Centering and shuttering including strutting propping etc, and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 41 Centering and shuttering including strutting propping etc, and removal of form for : Suspended floors, roofs, landings, balconies and access platform 42 Centering and shuttering including strutting propping etc, and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers 43 Centering and shuttering including strutting propping etc, and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts 44 Carriage of Timber by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 45 Brick work with common burnt clay F.P.S.(non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 46 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 (1 cement : 6 coarse sand) 47 Carriage of Bricks by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 48 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) 49 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 50 15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement: 4 coarse sand) 51 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 coarse sand) 52 Finishing with Acrylic smooth exterior paint of required shade: New work (two or more coat applied @ 1.67 ltr/10 sqm. Over and including priming coat of exterior primer applied @ 0.90 Lt./ 10 sqm.) 53 Finishing with Acrylic smooth exterior paint with Silicone additives of required shade: New work (two or more coat applied @ 1.43 ltr/10 sqm. Over and including priming coat of exterior primer applied @ 0.90 Lt./ 10 sqm.) 54 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 55 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. 56 Providing & mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck, using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer’s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of selfhealing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 57 Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/ honey-comb area of concrete/ masonry by suitable gun/ pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (The payment shall be made on the basis of actual weight of approved grout injected.) Stirrer mixed SBR Polymer (of approved make) modified Cement slurry made with Shrinkage Compensating Cement in concrete/ RCC work. 58 Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/ honey-comb area of concrete/ masonry by suitable gun/ pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (The payment shall be made on the basis of actual weight of approved grout injected.)Epoxy injection grout in concrete/RCC work of approved make 59 50 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. (At riser and skirting also) Red sand stone. 60 50 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. (At riser and skirting also) White sand stone. 61 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone / granite. 62 Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre. 63 Stone work in plain ashlar in super structure upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with cement mortar 1:2 (1white cement :2 stone dust) with an admixture of pigment matching the stone shade :Both face dressed. Red sand stone 64 Stone work in plain ashlar in super structure upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with cement mortar 1:2 (1white cement :2 stone dust) with an admixture of pigment matching the stone shade :Both face dressed. White sand stone 65 Kota stone (25mm thick) slab flooring over 20 mm (avg) thick base laid over & jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing & polishing complete with base of cement mortar 1:4 (1 cement :4 coarse sand): 66 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 67 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.- Polished Granite stone slab of approved colour 68 Providing and laying gang saw cut, mirror polished pre-moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. completeas per direction of Engineer-in-Charge.Granite 30mm thick of any colour and shade 69 Extra for sand blasted finish over granite stone as per design requirement. 70 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Red sand stone - exposed face fine dressed with roughbacking - 30mm thick 71 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : White sand stone - exposed face fine dressed with roughbacking - 30mm thick 72 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. 73 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases. 74 Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge.(The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). Red sand stone - 30mm thick gang saw cut stone 75 Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge.(The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). White sand stone - 30mm thick gang saw cut stone 76 Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) of size 300x230x300 mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/ RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-in-Charge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/ planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid). 77 Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-in-charge. 78 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 79 Providing and Fixing of Stone bollard 150mm dia and 900mm high including foundation of the bollard. All complete as per approved drawing, sample and directed by Engineer-in-Charge. 80 Providing and fixing stainless steel (Grade 304) railing, gate, Changeroom, Bin, etc. (Matt / Glossy finish) made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-Charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 81 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. All complete as per approved drawing, sample and directed by Engineer-in-Charge. Red sand stone 82 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. All complete as per approved drawing, sample and directed by Engineer-in-Charge. White sand stone 83 Designing, providing and Fixing of Sitting pavillion of 3x3 mt. (c/c) with 4 nos. Stone columns of avg. 350x350mm and Stone tie beam 250x450mm with 300mm projection from bottom of beam having clear height of3.0 mtr. above finish level including design depicted with the help of carving, embossing, engraving and inserting along with base of the column as per approved design based on Client/ Architects input. (Foundation works is in civil scope). All complete as per approved drawing, sample and directed by Engineer-in-Charge. (refer reference drg.) 84 Designing, providing and installing of PVC/ PVDF composition of coated composite material as per conceptual drawing. The flexible composite material (fabric) have characteristics of High tenacity polyster: Tio2 reinforced PVC coating and PVDF coated both sides, etc. All complete including Fabric wire rope 16mm, Anchor bolts to tie with RCC/ Stone Column, etc. as per approved drawing, sample and directed by Engineer-in-Charge. (refer reference drg.) (Plan area shall be measured.) 85 Designing, providing and installation of Post top light in Stone column of size 300mm dia (avg.) x 3.0 mtr. high (height incl. square base) inclusive of carving, embossing, engraving, insertion, etc. with LED light fixture. (Foundation works is in civil scope). All complete as approved and directed by Engineer-in-Charge. 86 Providing and applying silicone based water repellent coating confirming to BS: 6477-1984 in 2 coats with a consumption of 6 sq.mtr/ litre per coat over the exposed surface including cleaning the surface making it free from dirt, oil grease, wax and all other contamination using mechanical tool, wire brush, compressed air followed by water washing and as per the manufacturer specification and direction of Engineer-in-charge. 87 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 88 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 89 Carriage of Stone Blocks, GI, CI, Stainless steel pipes below 100mm dia and other heavy material by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 90 Supply and Installation of Light Fixtures. 91 Supply and installation of 4000mm Florian pole made of circular mild steel pipe of two section (grade YST 210) Bottom section 139.7mm Dia x 3.6mm thick with 1200mm Height & Top section 76.1mm Dia x 2.6mm thick with 2695mm Height. On the top of the pole a decorative flower arrangment as shown in the image. Decorative base made of Gravity Die-cast aluminium (436mm Dia x 481mm Height). Decorative Die- cast Aluminium cone (180mm Dia x 175mm Height) covered on the both section joint area. Pole section welded by certified welders using high end MIG welding processes. PDC aluminium service door 348mm height x 110mm width shall be provided with the company logo embossed on the bottom of the door and safety rope. The control gear tray is prewired with 2.5 Sq.mm cable, 6A SP MCB and 32A Ramanuj stud type 4 way terminal block for loop-in / loop-out arrangement, 5A 2 Way terminal connector and provision for earthing. Any other internal cables and connections shall not be covered in the scope of supply. Mild steel mounting plate 200mm Square x 12mm thick Steel of grade E250 to IS 2062 : 2011 with 4 elongated holes 38 x 19 to suit M16 x 300mm bolts of grade 4.6 at CC 140. The base plate have a cable entry hole of 70mm dia at the center. This mounting steel plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation. All dimension are within +/- 5% tolerance. After fabrication, entire pole is shot blasted (Inhouse). The pole is coated with zinc rich primer & pure polyester powder coating or epoxy zinc phosphate primer and finished using environmentally stable polyurethane based paint (coating thickness 60-80 microns). The Pole shall be provided with Graphite grey / Anthracite grey / Black as standard colour options. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-Charge. Make K-lite/ Unilamp/ Havells and Phillips 92 Supply and installation of 45-50W Post top with LED 3000K, 4000K, 5700K 240Vac CRI >80 MacAdam step 3 Dimension not less than Ø400 x 807 mm, Light Distribution360° Electronic driver ON/OFF, IP rating IP65, Spun aluminium top cover Ø400 mm of 1.6mm thickness, die cast aluminium decorative knob on top, Mild steel (Sand Blasting with zinc primer supporting arm integrated with die-cast aluminium base suitable for mounting Ø76mm OD pipe. SS fasteners. Pure polyester powder coated process : Acid treatment & pure polyester powder coating. Clear acrylic diffuser with controlled downward light emission. Lamp fixed position. Lumen efficacy should be minimum 120lm/W. This luminaire should contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire >56,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >88%, power factor >0.96, THD <10%, Surge protection 6KV. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-Charge. Make: K-Lite/ Unilamp/ Philips 93 Supply and installation of Surface mounted LED linear with system power [20W ± 5%], should be available in 3000K/4000K/6000K color temperature, maximum dimesnion 1200 x 43 x 52mm should be made up of High-Grade Aluminium with Die-cast Endcaps, Diffuser/ Lens Material : Polycarbonate, Secondary : Hexa-Cell (Matt Black), UGR<16, dali dimmable driver operational voltage range of 90-265V, power factor > 0.9, THD < 10%, Inbuilt surge protection of 3 KV, Luminaire has Ingress protection ofIP20. The luminaire should have minimum lumen outputof 100lm/W, CRI of >80. The LEDs used have a life of 50,000 burning hrs Lumen maintenance as per L70B10 with SDCM<=3 binning Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities Make of LEDs - LEDs of CREE / LUMINOUS / OSRAM / SEOUL / SAMSUNG/LUMILED / NICHIA/ CITIZEN, the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of materialCE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-Charge. Make: K-Lite/ Unilamp/ Havells and Phillips 94 Supply and installation of Static White 3000K surface mounted compact spot light designed to provide directional light. Beam angle 15° / 25° / 40°. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive A2 stainless steel fasteners. Clear toughened glass of 4mm thickness. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression.Power consumption should be between 10W to 12W at steady state full intensity luminaire should have minimum luminous flux of 1054 Lm. Color rendering index CRI ≥ 80 and power factor of complete luminaire ≥ 0.90, at white colour.Swivel range of 0° - 90°. Single cable entrance M10 cable gland. Protection class IP65/66. Mechanical resistance IK06.Pure polyester powder coated graphite grey / anthracite grey / jet black. Available colour temperature 3000K / 4000K, Colour rendering index (CRI)>80. SDCM-3 MacAdam. LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire 113 x 84 x 117mmmm. Adequate heat sink with proper thermal management shall be provided. Operating Temperature : -10°C to +50°C, Operating Humidity : 10%-90%. THD should be less than 10%. Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities Make of LEDs -LEDs of CREE / LUMINOUS / OSRAM / SEOUL / SAMSUNG/ LUMILED /NICHIA/CITIZEN, the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of materialCE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-Charge. Make: K-Lite/ Unilamp/ Havells and Phillips 95 Supply and installation of Decorative Pole Height 6M with Cast Iron Base made of circular mild steel pipe of two section (ISI Marked, grade YST 210), Bottom section & Top section 114.3mm Dia x 3mm thick respectively. Decorative Golden ring made of Die cast Aluminium at jointing section of two pipes (230mm Dia x 250mm Height) . Decorative base made of Gravity Die-cast aluminium or CI base approximately A/f 420mm and 966mm Height. Wind speed considered in design 50 m/sec in compliance with IS 875 Part 3 : 1987. Wind pressure calculation as per IS 875 (part-3) & structural calculation report certified by any Government Institution as per EN40 should be submitted to verify the pole design. Pole section welded by certified welders using high end MIG welding processes. PDC aluminium service door 348mm height x 110mm width shall be provided with the company logo embossed on the bottom of the door and safety rope with IP protection rating. The Double arm pelican jesy bracket is a split constructed type, Bracket stem made of MS Pipe 60.3mm Dia x 2.6mm thick, emerging from a Gravity Diecast Aluminium embellishments.The Bracket is crowned at top with CNC cut Chakra of Appropriate size. The artistically curved single arm made of MS pipe 38.1mm Dia x 2mm thick, with gravity diecast aluminium leaves Shaped embellishment, is firmly held to the stem by way of MS clamps and the arm bears cast iron knobs at one end and other ends facilitates the fitment of luminaire at 800mm on either side from the vertical axis of the bracket stem, it should be highlighted with 6W surface mounted compact spot light designed to provide directional light. Beam angle 15° / 25° / 40°. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive A2 stainless steel fasteners. Clear toughened glass of 4mm thickness. Surface mounting spike made of polypropylene black. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Swivel range of 0° - 90°. Single cable entrance M10 cable gland. Protection class IP65. Mechanical resistance IK06. Pure polyester powder coated graphite grey/ anthracite grey/ jet black. Available colour temperature 3000K/ 4000K/ 5700K, Colour rendering index (CRI)>80. SDCM-3 MacAdam. 96 Supply and installation of pendent type 50W LED, pendant mounted compact street light. Asymmetrical light distribution. Decorative luminaire made of pressure die cast aluminium body of high corrosion resistance and non corrosive stainless steel fasteners. Clear toughened glass diffuser of 5mm thickness. The module have polycarbonate optical lens with extruded aluminium heatsink for thermal management with vertical fin design for longer life of the LEDs. Slight regressin the optical assembly for better glare control. The mounting arrangement nipple, coupling & Hex nut made of Stainless steel 304 suitable for mounting to internally threaded pipe of designation M30. Protection class IP65. Mechanical resistance IK10. Pure polyester powder coated RAL 9004 Signal black, RAL 9007 Grey aluminium, RAL 7016 Anthracite grey. Available colour temperature 3000K / 4000K / 5700K, Colour rendering index (CRI)>70. SDCM-3 MacAdam. LED module with expected service life of at least 1,00,000 operating hours with luminous efficacy of 140 lm/W at 4000K and with T-IV optics. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >85%, Power factor >0.95, THD <10%, Surge protection 6KV. Make of LEDs of CREE / LUMINOUS/ OSRAM/ SEOUL/ SAMSUNG/ LUMILED/ NICHIA/ CITIZEN. Luminaire dimension Should not be more than : 490mm diameter x 160mm height. Manufacturer must have inhouse NABL certified lab equipped with photo goniometer, IP, IK test facilities CE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-Charge. Make: K-Lite/ Unilamp / Havells and Phillips 97 Supply and installation of 12W square decorative leser cut designer bollard LED 3000K, 4000K, 6500K 230-240Vac CRI >80 MacAdam step-3 Height910mm Light DistributionSymmetrical, Electronic driver ON/ OFF LUMINAIRE TYPE Bollard. IP rating IP66, Extruded square aluminium tube (grade 6063 with test certificate) Sq. 150 x 3mm thickness. Should have Bespoke laser cutting design options. SS fasteners. Must be equipped with Pre treated epdm black gaskets. Should have Die-cast aluminium mounting plate Sq.150 x 4mm thick with 3 elongated holes 20 x 12 to suit M10 bolts at PCD 90 with pure polyester powder coating. This mounting plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foudation. Hot dip galvanised foundation bolt. Mechanical resistance IK06. It should be Pure polyester powder coated process: Acid treatment & pure polyester powder coating. Optical grade clear toughened glass diffuser of 4mm thickness with controlled downward light emission. Lamp fixed position. This luminaire should contains built-in IP 65 LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >85%, power factor >0.9, THD <10%, Surge protection 2.5KV. Manufacturer must have inhouse NABL certified lab equipped with photo goniometer, IP, IK test facilities. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-Charge. Make: K-Lite/ Unilamp / Havells and Phillips 98 Supply and installation of White 3000K 1W In-ground with in built honey comb louvre symmetrical luminaire made up of die-casting withØ34 x 62 mm,the Ø34front ring should be made up of stainless steel 316 grade front ringwith silicone black gasket and toughened clear glass diffuser. The luminous flux of the luminaire is upto 169.06 lm for 3000K BEAM - 40. The ingress protection is IP67 and impact resistance of IK06. The luminaire is integrated with high power CITIZEN COB with CRI≥80, SDCM≤3, L70/ B10 @ 60000 Hrs. The integral constant current driver comes with the power factor greater than or equal to 0.9, total harmonic distortion less than 15% with operating efficiency greater than 80% and a surge protection of 2KV. The driver input voltage 240Vac at 50-60Hz, operating voltage of 100-277Vac and operating temperature of -20˚ ~ +40˚C. Adequate heat sink with proper thermal management shall be provided. Operating Humidity : 10%-90%. THD should be less than 10%. The fixtures proposed must have passed LM 79 & LM-80, Reports from NABL laboratory will be submitted post the issuance of LOA to the successful bidder and before the supply of material. Make of LEDs -LEDs of CREE / LUMINOUS / OSRAM / SEOUL / SAMSUNG/ LUMILED /NICHIA/CITIZEN. CE & BIS Certified. Manufacturer must have inhouse NABL certified lab equipped with photo goniometer, IP, IK test facilities. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-Charge. Make: K-Lite/ Unilamp / Havells and Phillips 99 Supply and installation of Input power : 12WCeiling-mounted compact down light emission designed to use monochromatic Warm white (3000K) & Neutral white (4000K). Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Extruded aluminium section with inner grooves to fix the top andbottom frame (grade 6063) ?100 x 3mm thickness, die-cast aluminium glass fixing frame ?100mm with clear toughened glass diffuser of 4mm thickness with ceramic black coated on outercorner siliconed to frame & die-cast aluminium cover for surface mounting on ceiling ?106mm (ADC12). Die-cast aluminium heat sink for excellent thermal management. Single cable entrance via black M10 cable gland (SS). All external screws are made of stainless steel. Clear silicone gasket. Protection class IP65. Mechanical resistance IK07. Acid treatment & pure polyester powder coated graphite grey / anthracite grey / jet black. The luminaires built-in LED module are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21). Operating ambient temperature range is from -15°C to +50°C. Beam angle 15° / 25° / 40°, Colour rendering index (CRI)>80. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >85%, Power factor >0.95, THD <10%, Surge protection 2.5KV. Manufacturer must have inhouse NABL certified lab equipped with photo goniometer, IP, IK test facilities . Luminaire square 106mm x height 150mm. CE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-Charge. Make: K-Lite/ Unilamp / Havells and Phillips 100 Supply and installation of6W, Wall-mounted compact down light emission designed to use monochromatic Warm white (3000K) & Neutral white (4000K). Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Extruded aluminium section with inner grooves to fix the top and bottom frame (grade 6063) Ø100 x 3mm thickness, die-cast aluminium glass fixing frame Ø100mm with clear toughened glass diffuser of 4mm thickness with ceramic black coated on outercorner siliconed to frame & die-cast aluminium top closing frame Ø100mm (ADC12). Die-cast aluminium heat sink for excellent thermal management. Single cable entrance via black PG7 cable gland, Die cast aluminium base for surface mounting on wall (ADC12). All external screws are made of stainless steel. Clear silicone gasket. Protection class IP65. Mechanical resistance IK07.Acid treatment & pure polyester powder coated graphite grey / anthracite grey / jet black. The luminaires built-in LED module are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21). Operating ambient temperature range is from -15°C to +50°C. Beam angle 15° / 25° / 40°, colour rendering index (CRI)>80. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor >0.90, THD <10%, Surge protection 2.5KV. Manufacturer must have inhouse NABL certified lab equipped with photo goniometer, IP, IK test facilities Luminaire dimension : 150mm length x 100mm width x 150mm height. CE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-Charge. Make: K-Lite/ Unilamp / Havells and Phillips 101 Supply and Installation of Light Fixtures. 102 Supply and installation of 7m multi head pole with provision of 8X45W Led, With diffrent beam angle as per requirement, bottom should be in two parts dia 139.7mm and top dia 88.9mm, Wind speed considered in design 50 m/sec in compliance with IS 875 Part 3 : 1987. Pole section welded by certified welders using high end MIG welding processes. Two PDC aluminium service door 348mm height x 80mm width shall be provided with the company logo embossed on the bottom of the door and safety rope with IP protection rating. The control gear tray is prewired with 2.5 Sq.mm cable, 6A MCB and 32A terminal connectors for loop-in / loop-out arrangement & Driver box. The Mild steel mounting plate 250mm Sq x 12mm thick Steel of grade E250 to IS 2062 : 2011 with 4 elongated holes 38 x 19 to suit M16 x 500mm bolts of grade 4.6. This mounting steel plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation. All dimension and weight are within +/- 5% tolerance. The pole is coated with pure polyester powder coating or epoxy zinc phosphate primer and finished using environmentally stable polyurethane based paint (coating thickness 60-80 microns). The Pole shall be provided with Graphite grey/ Anthracite grey/ Black as standard colour options Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities Make of LEDs - LEDs of CREE/ LUMINOUS/ OSRAM / SEOUL / SAMSUNG/ LUMILED/ NICHIA/CITIZEN, the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of material CE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-Charge. Make: K-Lite/ Unilamp / Havells and Phillips 103 Supply and installation of 70W LED Spot beam light, Integral control gear, should be maximumu Dimension : Ø210 x 216 x 268 Mounting: Surface ProductFinish: Grey IP: 65/66, should be made from Pressure Die-Cast Aluminium and toughened glass, Luminaire should be capable8° / 12° / 24° / 40° / 60 ° / 40°x11°. Should have different options in beam angles, Luminaire should be complete with driver and capable of operating at line voltage of 100-270 Vac, 50Hz with PF of >0.9, Fixture should be capable to operate at ambient temperature range of -20-to +40°C and should be IP65 and IK07, LED life of L70 B10 60,000 H. Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities Make of LEDs -LEDs of CREE/ LUMINOUS/ OSRAM/ SEOUL/ SAMSUNG/ LUMILED/ NICHIA/ CITIZEN, the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of materialCE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-Charge. Make: K-Lite/ Unilamp / Havells and Phillips 104 Supply and installation of IP rating IP67, Linear grazer Input power : 10W, 2700K, 3000K, 4000K24Vdc CRI >80 MacAdam step 3 Dimension not more than 1010 x 17 x 9mm Beam angle: 120° Electronic driver ON/OFF (External driver), High-Grade aluminum & Endcaps, Polyurethane Encapsulation diffuser. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire >60,000 hours at 40°C. Operating ambient temperature range is from -25°C to +55°C. Must be operated with 24V DC External Driver efficiency >85%, power factor >0.90, Surge protection 3KV. Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities Make of LEDs -LEDs of CREE/ LUMINOUS/ OSRAM/ SEOUL/ SAMSUNG/ LUMILED/ NICHIA/ CITIZEN, the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of materialCE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-Charge. Make: K-Lite/ Unilamp / Havells and Phillips 105 Supply and installation of Static White 3000K surface mounted compact spot light designed to provide directional light. Beam angle 15°/ 25°/ 40°. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive A2 stainless steel fasteners. Clear toughened glass of 4mm thickness. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Power consumption should be between 10W to 12W at steady state full intensity luminaire should have minimum luminous flux of 1054 Lm. Color rendering index CRI ≥ 80 and power factor of complete luminaire ≥ 0.90, at white colour. Swivel range of 0° - 90°. Single cable entrance M10 cable gland. Protection class IP-66. Mechanical resistance IK06. marine grade coating graphite grey / anthracite grey / jet black. Available colour temperature 3000K/ 4000K, Colour rendering index (CRI)>80. SDCM-3 MacAdam. LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire 113 x 84 x 117mm. Adequate heat sink with proper thermal management shall be provided. Operating Temperature: -10°C to +50 C, Operating Humidity : 10%-90%. THD should be less than 10%. Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities Make of LEDs -LEDs of CREE/ LUMINOUS/ OSRAM/ SEOUL/ SAMSUNG/ LUMILED/ NICHIA/ CITIZEN, the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of materialCE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-Charge. Make: K-Lite/ Unilamp / Havells and Phillips 106 Supply and instllation of 9W/m encapsulated silicon flex, should be at least IP 67 3000K 24Vdc CRI >80 MacAdam step 3 Beam angle: 120°, Should be equipped with dot less homogenous lighting effect Electronic driver ON/OFF (External driver) Material Characteristics: Copper coated strip, Silicone moulded diffuser, End cap,Clip. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 50,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >70%, Power factor >0.80, Surge protection 3KV. Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities Make of LEDs -LEDs of CREE/ LUMINOUS/ OSRAM/ SEOUL/ SAMSUNG/ LUMILED/ NICHIA/CITIZEN, the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of materialCE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-Charge. Make: K-Lite/ Unilamp / Havells and Phillips 107 Supply and installation of Customised narrow spot light of 6-8W LED, should be available in LED colors 3000K, 4000K, 6000K 24Vdc CRI >80 MacAdam step 5, should have maximum Dimension of 65 x 55 x 99mm and with beam angle of 2°, IP rating 66, Made from Die Cast Aluminium Alloy. Toughened clear glass diffuser. SS fasteners. Aluminium mounting bracket for surface mounting on ground. Toughened Clear glass diffuser and optical to reduce glare controlled. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Must be operated with 24V DC External Driver efficiency >85%, power factor >0.90, Surge protection 3KV. 108 Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities Make of LEDs -LEDs of CREE/ LUMINOUS/ OSRAM/ SEOUL/ SAMSUNG/ LUMILED/ NICHIA/ CITIZEN, the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of materialCE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-charge. Make: K-Lite/ Unilamp / Havells and Phillips 109 Supply and installation of IP rating IP67 linear wall washer. Input power: 20W, 2700K, 3000K, 4000K 24Vdc CRI >80 MacAdam step 3 Dimension not more than 1005x 25x 32mm Beam angle : 30/60° Electronic driver ON/OFF (External driver), High-grade aluminum & Endcaps, Polyurethane Encapsulation diffuser. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire >60,000 hours at 40°C. Operating ambient temperature range is from -25°C to +55°C. Driver efficiency >85%, Surge protection 3KV. and before the supply of materialCE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-Charge. Make: K-Lite/ Unilamp / Neri 110 Trenching in ordinary soil up to a depth of cm including removal and stacking of serviceablematerials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/ and manure before and after flooding trench with water (excluding cost of imported earth, slude or manure). 111 Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manureafter reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking anddisposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately). 112 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 part ofstacked volume of earth after reduction by 20% :1 part of stacked volume of manure after reductionby 8%) flooding with water, dressing including removal ofrubbish and surplus earth, if any with allleads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Holes 120 cm dia, and 120 cm deep 113 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1byvolume(2partofstackedvolumeofearthafter reduction by 20% :1 part of stacked volume of manure after reductionby8%)floodingwithwater,dressingincluding removalofrubbishandsurplusearth,ifany withallleads andlifts(costofmanure,sludgeorextragoodearthif needed to be paid for separately)Holes60 cm dia , and 60 cm deep 114 Supplying and stacking of cow dung manure/cattle manure atsite including cost and carriage with all lead and lifts, (manuremeasured in stacks will be reduced by 8% of payment) 115 Supplyingand spreading of fertilizer & pesticides at site of work DAP 116 Mixing earth and sludge or manure in proportion specified or directed. 117 Spreading of sludge, dump manure or/ and good earth in required thickness (cost of sludge dump manure or/ and good earth to be paid separately) 118 Rough dressing the trenched ground including breaking of clods. 119 Providing and planting of Michelia champa (Golden Champa) of height 12-0 in earthen pots of size 14 as per direction of the Engineer-in-Charge. 120 Providing and planting of Tabernaemontana divaricata (Chandnidouble) of height 12-0, bushy in big size HDPE bag as per direction of the Engineer-in-Charge. 121 Providing and planting of Azadirachta indica (Neem) of height 12-0 in big polybag of size 14 as per direction of the Engineer-in-Charge. 122 Providing and planting Bougainvillea named variety, Sobhra, Thima, Marry palmar, Cherry Blossom etc. well developed with fresh & healthy bushy in full bloom 4.0 ht. in 40 cm Cement Pot as per direction of the Engineer-in-Charge. 123 Providing and stacking of Terminalia arjuna of 12.0 height. in big polybags of size 25 cm as per direction of the Engineer-in-Charge. 124 Flooding the ground with water including making Kiaries and dismantelling the same 125 Grassing with selection no-1, grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free fromweeds and fit for mowing including supplying goodearth if needed (the good earth shall be paid for separately) With grass Turf 126 Removal of garden rubbish including building rubbish, earth with or / and mulba excavated by mechanical transport with all lead and lift. 127 Providing & laying Selection no. 1 doob grass turf with earth 100mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly, as per direction of Engineer-in-Charge. 128 Designing, providing, fabrication and placing Sand Stone 3-seater Bench placed on ground including base/ foundation as per approval. The stone should be carved using CNC machine. Before execution, the agency shall submit shop drawings with all necessary details. Mock-up at site shall be put as per approved shop drawing. Final execution shall be done as per tested and approved mock-up. All complete as per approved drawing, sample and directed by Engineer-in-Charge. (refer reference drg.) 129 Designing, providing, fabrication and placing dustbin of SS 304 having an outer frame in SS finish fixed to the ground and drum made of 4mm thick sheet fixed on pivot over the outer frame. Drum finish is matt from outside and polished from inside. High proformance rust proof treated outer wall with invisible seamless welded. Sand stone of 100 mm thick fixed at bottom of the frame. Placed over the hard firm base. The dustbins with the complete framework and with all necessary hardware, brackets, clits, base, etc. all complete shall be fixed over the pedestal. Before execution, the agency shall submit shop drawings with all necessary details. Mock-up at site shall be put as per approved shop drawing. Final execution shall be done as per tested and approved mock-up. All complete as per approved drawing, sample and directed by Engineer-in-Charge. (refer reference drg.) 130 Supply installation, testing and commissioning of Water ATM/ Purified Water Vending Machine Power Supply- AC 220V 50Hz/ AC 110 V 60 Hz- Production capacity 3000 GPD- Water Tank capcity- 200 L- UV power- 20 W- Ozone capacity- 1000 mg, Filling Flow Rate- 8 L/min-Selling Method- IC card coins paper note, Size of filling bottle- 200 ml, 500 ml,1L, 2L,20Ltr ( at a time in one tap), Filteration step- 9 steps, Size- L80 cmxW68 cmxH200 cm, Packing-Carton for FCL or Poly wood case for LCL, 19 inch for adertisement LCD panel, Reverse Osmosis (RO), Ultra Violet (UV) Technology, Ozonation Water chiller LED Technology. All complete including over head water tank, base of Kiosk and shed with foundation as per approval of Engineer-in-Charge. 131 SUB HEAD -I ELECTRICAL PANELS- FEEDER PILLAR-01 (IP-67) INCOMER MCCB 415V, 50Hz, 100A, 4P, 25kA for 1 sec rated thermal magnetic based MCCB with inbuilt LSIG protection- 1 Nos.Indication lamps LED type phase indication lamps suitable for 230V,50Hz AC (red, yellow, blue) - 1 Set.LED type Indication lamps for breaker, suitable for 230V,50Hz AC supply (on, off, trip) - 1 set With Photo Sensor/LUX Sensor + Timer With Astronomical Switch BUS BAR-Busbar (1 Set - 4P + E)Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 150 A, 25 kA for 1 sec of required length and cross sectional area. OUTGOINGS- MCB18Nos. 415V, 50Hz, 25A, DP, 10 kA MCB.24Nos. 415V, 50Hz, 32A, DP, 10 kA MCB. 132 SUB HEAD- II : EARTHING-Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 133 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 134 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 135 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. 136 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe From earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. 137 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 138 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 139 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 140 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 141 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 142 SUB HEAD- III : CABLE & CABLE TERMINATION- Supplying following 1.1kV grade, heavy duty XLPE insulated, FRLS type armoured /Unarmured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete as required. 3.5C x 50 sqmm A2XFY 143 3C x 6 sqmm 2X 144 3C x 4 sqmm 2X 145 1C x 4 sqmm 2XY 146 Supplying and making end termination with brass compression gland and cuppor lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3½ X 50 sq. mm (35 mm) 147 Supplying and making end termination with aluminium lugs for following size of aluminium conductor cable of 1.1 kV grade as required.3C X 6sq. Mm 148 3C X 4sq. mm 149 SUB HEAD-IV:CIVIL WORK- Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) 150 90 mm dia (OD-90 mm & ID-76 mm nominal) 151 Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 152 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 80 m : All Kinds of Soil. Pipes, cables etc., exceeding 80mm dia but not exceeding 300mm dia 153 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm diameter 154 200 mm diameter 155 250 mm diameter 156 300 mm diameter 157 Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) with RCC Top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20mm nominal size) foundation concrete 1:4:8 mix ( 1 cement :4 coarse sand: 8 graded stone aggregate 40 nominal size), inside plastering 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand),finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80 cm and 50 cm deep including perforated C.I. / RCC cover with frame (Heavy duty) 455x610 mm internal dimensions 158 Inside size 120x90 cm and 90 cm deep including C.I./RCC cover with frame (heavy duty) 560 mm internal diamete 159 Providing & fixing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per I.S:10910 on 12 mm dia steel bar conforming to I.S:1786 having minimum cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 165 mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturers permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15cm cement concrete block 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size) complete as per design. 160 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 300 to 350 mm diameter 161 For pipes 250 to 300 mm diameter 162 Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.4 163 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 500x700 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design. Dimensions 500x700 mm & 45 cm deep for pipe line with one or two inlets. With common burnt clay F.P.S. (non modular) bricks of class designation 7.4 164 GST Extra as applicable
Contract Date: Apr 01, 2026 Contract Value : 3.20 Crore
Government Departments No of Bidders 2
Uttar Pradesh View Result →
50.
Housing Urban and Rular Development #9499910 Technical Bid
Tender For Proposed Rejuvenation And Development Of Tourist Facilities At Assi Ghat At Varanasi(U.P.) (Notice No. -64/Uppcl/Gm-1/2025-26/E-Tenderdated: 22.08.2025) - Proposed Rejuvenation and Development of Tourist Facilities at Assi Ghat at Varanasi(U.P.) 2 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed as directed by Engineer-in- charge.All kinds of soil 3 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming & watering, lead up to 50 m and lift upto 1.5 m. 4 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 5 Carriage of Earth by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 6 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. - Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 7 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 8 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 9 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 10 Demolishing stone pitching in floors, slopes, etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 11 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 12 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete 13 Carriage of Rubbish by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 14 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. 15 Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete. 16 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. 17 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 18 Same as item 16. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 19 Carriage of Soling Stone by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 20 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 21 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 22 1:3:6 (1 Cement : 3 coarse sand (zone-Ill) derived from natural sources :6 graded stone aggregate 40 mm nominal size derived from natural sources) 23 Carriage of Stone Aggregate 40mm nominal size and above by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 24 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 25 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.Concrete of M25 grade with minimum cement content of 330 kg /cum.All works upto plinth level 26 All works above plinth level upto floor V level. Concrete of M25 grade with minimum cement content of 330 kg /cum 27 Carriage of Sand, Stone Aggregate below 40mm by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 28 Add for using extra cement in the items of design mix over and above the specified cement content therein. 29 Carriage of Cement by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 30 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator, vacuum dewatering process and finally finished by floating, brooming with wire brush etc. All complete including shutting, channel, etc. as per specifications and directions of Engineer-in-charge. 31 Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) :400 mm dia piles 32 Same as item 30 but 500 mm dia piles 33 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/ Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing.Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge.Single pile upto 50 tonne Safe capacity. Initial test (Test Load 2.5 times the Safe capacity) 34 Same as item 32 but Routine test (Test Load 1.5 times the Safe capacity) 35 Same as item 32 but Single pile above 50 tonne and upto 100 tonne Safe capacity Initial test (Test Load 2.5 times the Safe capacity) 36 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete for all lift and level.Thermo-Mechanically Treated bars (Fe500d) 37 Carriage of Steel by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 38 Centering and shuttering including strutting propping etc, and removal of form for : Foundations, footings, bases of columns etc., for mass concrete 39 Centering and shuttering including strutting propping etc, and removal of form for :Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 40 Centering and shuttering including strutting propping etc, and removal of form for :Suspended floors, roofs, landings, balconies and access platform 41 Centering and shuttering including strutting propping etc, and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers 42 Centering and shuttering including strutting propping etc, and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts 43 Carriage of Timber by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 44 Brick work with common burnt clay F.P.S.(non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 45 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 (1 cement : 6 coarse sand) 46 Carriage of Bricks by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 47 12 mm cement plaster of mix :1:4 (1 cement: 4 coarse sand) 48 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 49 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) 50 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand) 51 Finishing with Acrylic smooth exterior paint of required shade: New work (two or more coat applied @ 1.67 ltr/10 sqm. Over and including priming coat of exterior primer applied @ 0.90 Lt./ 10 sqm.) 52 Finishing with Acrylic smooth exterior paint with Silicone additives of required shade:New work (two or more coat applied @ 1.43 ltr/10 sqm. Over and including priming coat of exterior primer applied @ 0.90 Lt./ 10 sqm.) 53 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. 54 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. 55 Providing & mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck, using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer’s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of selfhealing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 56 Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/ honey-comb area of concrete/ masonry by suitable gun/ pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (The payment shall be made on the basis of actual weight of approved grout injected.) Stirrer mixed SBR Polymer (of approved make) modified Cement slurry made with Shrinkage Compensating Cement in concrete/ RCC work. 57 Same as item 55 but Epoxy injection grout in concrete/RCC work of approved make 58 50 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. (At riser and skirting also). Red sand stone 59 50 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. (At riser and skirting also).White sand stone 60 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone / granite. 61 Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre. 62 Stone work in plain ashlar in super structure upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with cement mortar 1:2 (1white cement :2 stone dust) with an admixture of pigment matching the stone shade : Both face dressed. Red sand stone 63 Stone work in plain ashlar in super structure upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with cement mortar 1:2 (1white cement :2 stone dust) with an admixture of pigment matching the stone shade : Both face dressed. White sand stone 64 Kota stone (25mm thick) slab flooring over 20 mm (avg) thick base laid over & jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing & polishing complete with base of cement mortar 1:4 (1 cement :4 coarse sand): 65 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 66 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.- Polished Granite stone slab of approved colour 67 Providing and laying gang saw cut, mirror polished pre-moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. completeas per direction of Engineer-in-Charge. Granite 30mm thick of any colour and shade 68 Extra for sand blasted finish over granite stone as per design requirement. 69 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Red sand stone - exposed face fine dressed with roughbacking - 30mm thick 70 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :White sand stone - exposed face fine dressed with roughbacking - 30mm thick 71 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. 72 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases. 73 Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge.(The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). Red sand stone - 30mm thick gang saw cut stone 74 Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge.(The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). White sand stone - 30mm thick gang saw cut stone 75 Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) of size 300x230x300 mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/ RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to theEngineer-in-charge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/ planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid). 76 Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-in-charge. 77 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 78 Providing and Fixing of Stone bollard 150mm dia and 900mm high including foundation of the bollard. All complete as per approved drawing, sample and directed byEngineer-in-charge. 79 Providing and fixing stainless steel (Grade 304) railing, gate, Changeroom, Bin, etc. (Matt / Glossy finish) made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval ofEngineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 80 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. All complete as per approved drawing, sample and directed by Engineer-in-charge. Red sand stone 81 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. All complete as per approved drawing, sample and directed by Engineer-in-charge.White sand stone 82 Designing, providing and Fixing of Sitting pavillion of 3x3 mt. (c/c) with 4 nos. Stone columns of avg. 350x350mm and Stone tie beam 250x450mm with 300mm projection from bottom of beam having clear height of3.0 mtr. above finish level including design depicted with the help of carving, embossing, engraving and inserting along with base of the column as per approved design based on Client/ Architects input. (Foundation works is in civil scope). All complete as per approved drawing, sample and directed by Engineer-in-charge. (refer reference drg.) 83 Designing, providing and installing of PVC/ PVDF composition of coated composite material as per conceptual drawing. The flexible composite material (fabric) have characteristics of High tenacity polyster: Tio2 reinforced PVC coating and PVDF coated both sides, etc. All complete including Fabric wire rope 16mm, Anchor bolts to tie with RCC/ Stone Column, etc. as per approved drawing, sample and directed byEngineer-in-charge. (refer reference drg.) (Plan area shall be measured.) 84 Designing, providing and installation of Post top light in Stone column of size 300mm dia (avg.) x 3.0 mtr. high (height incl. square base) inclusive of carving, embossing, engraving, insertion, etc. with LED light fixture. (Foundation works is in civil scope). All complete as approved and directed by Architect and Engineer-in-charge. 85 Providing and applying silicone based water repellent coating confirming to BS: 6477-1984 in 2 coats with a consumption of 6 sq.mtr/ litre per coat over the exposed surface including cleaning the surface making it free from dirt, oil grease, wax and all other contamination using mechanical tool, wire brush, compressed air followed by water washing and as per the manufacturer specification and direction of Engineer-in-charge. 86 Research, designing, providing and fixing of stainless steel(Grade 316) (Matt / Glossy finish) 50x50mm hollow circular pipe in ring shape of 4 different sizes of diameter 1650mm, 2350mm, 2850mm & 3150mm of 3mm thickness respectively placed in ascending order from top creating a umbrella structure and fixed on a column (Stone/ Metal) as per approved design based on Client and Architects input of height 2800mm (having a SS capital on top) and a SS pipe arch of 90mm dia. & 3.6mm thick and of radius 1625mm. IP65 rated LED strip light placed on 15mm SS flat welded to the inner side of the SS ring and laser cut SS Diya of size 1050x900mm of desired thickness between the portals and work includes welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete of required sizeetc. (Foundation is in civil scoppe). All complete as per approved drawing, sample and as directed by Engineer-in-charge. (refer reference drg.) 87 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 88 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 89 Carriage of Stone Blocks, GI, CI, Stainless steel pipes below 100mm dia and other heavy material by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 90 Supply and Installation of Light Fixtures. 91 Supply and installation of 4000mm Florian pole made of circular mild steel pipe of two section (grade YST 210) Bottom section 139.7mm Dia x 3.6mm thick with 1200mm Height & Top section 76.1mm Dia x 2.6mm thick with 2695mm Height. On the top of the pole a decorative flower arrangment as shown in the image. Decorative base made of Gravity Die-cast aluminium (436mm Dia x 481mm Height). Decorative Die- cast Aluminium cone (180mm Dia x 175mm Height) covered on the both section joint area. Pole section welded by certified welders using high end MIG welding processes. PDC aluminium service door 348mm height x 110mm width shall be provided with the company logo embossed on the bottom of the door and safety rope. The control gear tray is prewired with 2.5 Sq.mm cable, 6A SP MCB and 32A Ramanuj stud type 4 way terminal block for loop-in / loop-out arrangement, 5A 2 Way terminal connector and provision for earthing. Any other internal cables and connections shall not be covered in the scope of supply. Mild steel mounting plate 200mm Square x 12mm thick Steel of grade E250 to IS 2062 : 2011 with 4 elongated holes 38 x 19 to suit M16 x 300mm bolts of grade 4.6 at CC 140. The base plate have a cable entry hole of 70mm dia at the center. This mounting steel plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation. All dimension are within +/- 5% tolerance. After fabrication, entire pole is shot blasted (Inhouse). The pole is coated with zinc rich primer & pure polyester powder coating or epoxy zinc phosphate primer and finished using environmentally stable polyurethane based paint (coating thickness 60-80 microns). The Pole shall be provided with Graphite grey / Anthracite grey / Black as standard colour options. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-charge. Make K-lite/ Unilamp/ Havells and Phillips or Equivalent. 92 Supply and installation of 45-50W Post top with LED 3000K, 4000K, 5700K 240Vac CRI >80 MacAdam step 3 Dimension not less than Ø400 x 807 mm, Light Distribution360° Electronic driver ON/OFF, IP rating IP65, Spun aluminium top cover Ø400 mm of 1.6mm thickness, die cast aluminium decorative knob on top, Mild steel (Sand Blasting with zinc primer supporting arm integrated with die-cast aluminium base suitable for mounting Ø76mm OD pipe. SS fasteners. Pure polyester powder coated process : Acid treatment & pure polyester powder coating. Clear acrylic diffuser with controlled downward light emission. Lamp fixed position. Lumen efficacy should be minimum 120lm/W. This luminaire should contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire >56,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >88%, power factor >0.96, THD <10%, Surge protection 6KV. All complete including consumables required for installation. Sample should be submitted for approval fromEngineer-in-charge. Make: K-Lite/ Unilamp/ Philips and Havells or Equivalent. 93 Supply and installation of Surface mounted LED linear with system power [20W ± 5%], should be available in 3000K/4000K/6000K color temperature, maximum dimesnion 1200 x 43 x 52mm should be made up of High-Grade Aluminium with Die-cast Endcaps, Diffuser/ Lens Material : Polycarbonate, Secondary : Hexa-Cell (Matt Black), UGR<16, dali dimmable driver operational voltage range of 90-265V, power factor > 0.9, THD < 10%, Inbuilt surge protection of 3 KV, Luminaire has Ingress protection ofIP20. The luminaire should have minimum lumen outputof 100lm/W, CRI of >80. The LEDs used have a life of 50,000 burning hrs Lumen maintenance as per L70B10 with SDCM<=3 binning Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities Make of LEDs - LEDs of CREE / LUMINOUS / OSRAM / SEOUL / SAMSUNG/LUMILED / NICHIA/ CITIZEN, the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of materialCE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-charge. Make: K-Lite/ Unilamp/ Havells and Phillips or Equivalent. 94 Supply and installation of Static White 3000K surface mounted compact spot light designed to provide directional light. Beam angle 15° / 25° / 40°. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive A2 stainless steel fasteners. Clear toughened glass of 4mm thickness. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression.Power consumption should be between 10W to 12W at steady state full intensity luminaire should have minimum luminous flux of 1054 Lm. Color rendering index CRI ≥ 80 and power factor of complete luminaire ≥ 0.90, at white colour.Swivel range of 0° - 90°. Single cable entrance M10 cable gland. Protection class IP65/66. Mechanical resistance IK06. Pure polyester powder coated graphite grey / anthracite grey / jet black. Available colour temperature 3000K / 4000K, Colour rendering index (CRI)>80. SDCM-3 MacAdam. LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire 113 x 84 x 117mmmm. Adequate heat sink with proper thermal management shall be provided. Operating Temperature : -10°C to +50°C, Operating Humidity : 10%-90%. THD should be less than 10%. Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities Make of LEDs -LEDs of CREE / LUMINOUS / OSRAM / SEOUL / SAMSUNG/ LUMILED /NICHIA/CITIZEN, the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of materialCE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval fromEngineer-in-charge. Make: K-Lite/ Unilamp/ Havells and Phillips or Equivalent. 95 Supply and installation of Decorative Pole Height 6M with Cast Iron Base made of circular mild steel pipe of two section (ISI Marked, grade YST 210), Bottom section & Top section 114.3mm Dia x 3mm thick respectively. Decorative Golden ring made of Die cast Aluminium at jointing section of two pipes (230mm Dia x 250mm Height) . Decorative base made of Gravity Die-cast aluminium or CI base approximately A/f 420mm and 966mm Height. Wind speed considered in design 50 m/sec in compliance with IS 875 Part 3 : 1987. Wind pressure calculation as per IS 875 (part-3) & structural calculation report certified by any Government Institution as per EN40 should be submitted to verify the pole design. Pole section welded by certified welders using high end MIG welding processes. PDC aluminium service door 348mm height x 110mm width shall be provided with the company logo embossed on the bottom of the door and safety rope with IP protection rating. The Double arm pelican jesy bracket is a split constructed type, Bracket stem made of MS Pipe 60.3mm Dia x 2.6mm thick, emerging from a Gravity Diecast Aluminium embellishments.The Bracket is crowned at top with CNC cut Chakra of Appropriate size. The artistically curved single arm made of MS pipe 38.1mm Dia x 2mm thick, with gravity diecast aluminium leaves Shaped embellishment, is firmly held to the stem by way of MS clamps and the arm bears cast iron knobs at one end and other ends facilitates the fitment of luminaire at 800mm on either side from the vertical axis of the bracket stem, it should be highlighted with 6W surface mounted compact spot light designed to provide directional light. Beam angle 15° / 25° / 40°. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive A2 stainless steel fasteners. Clear toughened glass of 4mm thickness. Surface mounting spike made of polypropylene black. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Swivel range of 0° - 90°. Single cable entrance M10 cable gland. Protection class IP65. Mechanical resistance IK06. Pure polyester powder coated graphite grey/ anthracite grey/ jet black. Available colour temperature 3000K/ 4000K/ 5700K, Colour rendering index (CRI)>80. SDCM-3 MacAdam. 96 Supply and installation of pendent type 50W LED, pendant mounted compact street light. Asymmetrical light distribution. Decorative luminaire made of pressure die cast aluminium body of high corrosion resistance and non corrosive stainless steel fasteners. Clear toughened glass diffuser of 5mm thickness.Stainless steel 304 suitable for mounting to internally threaded pipe of designation M30. Protection class IP65. Mechanical resistance IK10. Pure polyester powder coated RAL 9004 Signal black, RAL 9007 Grey aluminium, RAL 7016 Anthracite grey. Available colour temperature 3000K / 4000K / 5700K, Colour rendering index (CRI)>70. SDCM-3 MacAdam. LED module with expected service life of at least 1,00,000 operating hours with luminous efficacy of 140 lm/W at 4000K and with T-IV optics. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >85%, Power factor >0.95, THD <10%, Surge protection 6KV. Make of LEDsof CREE / LUMINOUS / OSRAM / SEOUL / SAMSUNG/ LUMILED / NICHIA/ CITIZEN. Luminaire dimension Should not be more than : 490mm diameter x 160mm height. Manufacturer must have inhouse NABL certified lab equipped with photo goniometer, IP, IK test facilities CE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Architect and Engineer-in-charge. Make: K-Lite/ Unilamp / Havells and Phillips or Equivalent.. The control gear tray is prewired with 2.5 Sq.mm cable,6A MCB and 32A terminal connectors for loop-in / loop-out arrangement. Mild steel mounting plate of round shape with 280x 12mm thick Steel of grade E250 to IS 2062 : 2011 with 4 elongated holes 38X19 to suit M16 x 500mm bolts of grade 4.6 at CC230. This mounting steel plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation. All dimension are within +/- 10% tolerance. Shot blasting process for surface preparation of pole before painting / powder coating is required. The manufacturer should have in-house shot blasting machine and salt spray testing equipment. Test report should be submitted. The pole is coated with zinc rich primer & pure polyester powder coating or epoxy zinc phosphate primer and finished using environmentally stable polyurethane based paint of desired RAL (coating thickness 60-80 microns).All complete including consumables required for installation. Sample should be submitted for approval fromEngineer-in-charge. Make:Havells and Phillips or Equivalent. 97 Supply and installation of 12W square decorative leser cut designer bollard LED 3000K, 4000K, 6500K 230-240Vac CRI >80 MacAdam step-3 Height910mm Light DistributionSymmetrical, Electronic driver ON/ OFF LUMINAIRE TYPE Bollard. IP rating IP66, Extruded square aluminium tube (grade 6063 with test certificate) Sq. 150 x 3mm thickness. Should have Bespoke laser cutting design options. SS fasteners.Should have Die-cast aluminium mounting plate Sq.150 x 4mm thick with 3 elongated holes 20 x 12 to suit M10 bolts at PCD 90 with pure polyester powder coating. This mounting plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foudation. Hot dip galvanised foundation bolt. Mechanical resistance IK06. Optical grade clear toughened glass diffuser of 4mm thickness with controlled downward light emission. Lamp fixed position. This luminaire should contains built-in IP 65 LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >85%, power factor >0.9, THD <10%, Surge protection 2.5KV. Manufacturer must have inhouse NABL certified lab equipped with photo goniometer, IP, IK test facilities. All complete including consumables required for installation. Sample should be submitted for approval fromEngineer-in-charge. Make: K-Lite/ Unilamp / Havells and Phillips or Equivalent. 98 Supply and installation of White 3000K 1W In-ground with in built honey comb louvre symmetrical luminaire made up of die-casting withØ34 x 62 mm,the Ø34front ring should be made up of stainless steel 316 grade front ringwith silicone black gasket and toughened clear glass diffuser. The luminous flux of the luminaire is upto 169.06 lm for 3000K BEAM - 40. The ingress protection is IP67 and impact resistance of IK06. The luminaire is integrated with high power CITIZEN COB with CRI≥80, SDCM≤3, L70/ B10 @ 60000 Hrs. The integral constant current driver comes with the power factor greater than or equal to 0.9, total harmonic distortion less than 15% with operating efficiency greater than 80% and a surge protection of 2KV. The driver input voltage 240Vac at 50-60Hz, operating voltage of 100-277Vac and operating temperature of -20˚ ~ +40˚C. Adequate heat sink with proper thermal management shall be provided. Operating Humidity : 10%-90%. THD should be less than 10%. The fixtures proposed must have passed LM 79 & LM-80, Reports from NABL laboratory will be submitted post the issuance of LOA to the successful bidder and before the supply of material. Make of LEDs -LEDs of CREE / LUMINOUS / OSRAM / SEOUL / SAMSUNG/ LUMILED /NICHIA/CITIZEN. CE & BIS Certified. Manufacturer must have inhouse NABL certified lab equipped with photo goniometer, IP, IK test facilities. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-charge. Make: K-Lite/ Unilamp / Havells and Phillips or Equivalent. 99 Supply and installation of Input power : 12WCeiling-mounted compact down light emission designed to use monochromatic Warm white (3000K) & Neutral white (4000K). Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Extruded aluminium section with inner grooves to fix the top andbottom frame (grade 6063) ?100 x 3mm thickness, die-cast aluminium glass fixing frame ?100mm with clear toughened glass diffuser of 4mm thickness with ceramic black coated on outercorner siliconed to frame & die-cast aluminium cover for surface mounting on ceiling ?106mm (ADC12). Die-cast aluminium heat sink for excellent thermal management. Single cable entrance via black M10 cable gland (SS). All external screws are made of stainless steel. Clear silicone gasket. Protection class IP65. Mechanical resistance IK07. Acid treatment & pure polyester powder coated graphite grey / anthracite grey / jet black. The luminaires built-in LED module are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21). Operating ambient temperature range is from -15°C to +50°C. Beam angle 15° / 25° / 40°, Colour rendering index (CRI)>80. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >85%, Power factor >0.95, THD <10%, Surge protection 2.5KV. Manufacturer must have inhouse NABL certified lab equipped with photo goniometer, IP, IK test facilities . Luminaire square 106mm x height 150mm. CE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-charge. Make: K-Lite/ Unilamp / Havells and Phillips or Equivalent. 100 Supply and installation of6W, Wall-mounted compact down light emission designed to use monochromatic Warm white (3000K) & Neutral white (4000K). Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Extruded aluminium section with inner grooves to fix the top and bottom frame (grade 6063) Ø100 x 3mm thickness, die-cast aluminium glass fixing frame Ø100mm with clear toughened glass diffuser of 4mm thickness with ceramic black coated on outercorner siliconed to frame & die-cast aluminium top closing frame Ø100mm (ADC12). Die-cast aluminium heat sink for excellent thermal management. Single cable entrance via black PG7 cable gland, Die cast aluminium base for surface mounting on wall (ADC12). All external screws are made of stainless steel. Clear silicone gasket. Protection class IP65. Mechanical resistance IK07. Acid treatment & pure polyester powder coated graphite grey / anthracite grey / jet black. The luminaires built-in LED module are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21). Operating ambient temperature range is from -15°C to +50°C. Beam angle 15° / 25° / 40°, colour rendering index (CRI)>80. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor >0.90, THD <10%, Surge protection 2.5KV. Manufacturer must have inhouse NABL certified lab equipped with photo goniometer, IP, IK test facilities Luminaire dimension : 150mm length x 100mm width x 150mm height. CE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval fromEngineer-in-charge. Make: K-Lite/ Unilamp / Havells and Phillips or Equivalent. 101 Supply and Installation of Light Fixtures. 102 Supply and installation of 7m multi head pole with provision of 8X45W Led, With diffrent beam angle as per requirement, bottom should be in two parts dia 139.7mm and top dia 88.9mm, Wind speed considered in design 50 m/sec in compliance with IS 875 Part 3 : 1987. Pole section welded by certified welders using high end MIG welding processes. Two PDC aluminium service door 348mm height x 80mm width shall be provided with the company logo embossed on the bottom of the door and safety rope with IP protection rating. The control gear tray is prewired with 2.5 Sq.mm cable, 6A MCB and 32A terminal connectors for loop-in / loop-out arrangement & Driver box. The Mild steel mounting plate 250mm Sq x 12mm thick Steel of grade E250 to IS 2062 : 2011 with 4 elongated holes 38 x 19 to suit M16 x 500mm bolts of grade 4.6. This mounting steel plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation. All dimension and weight are within +/- 5% tolerance. The pole is coated with pure polyester powder coating or epoxy zinc phosphate primer and finished using environmentally stable polyurethane based paint (coating thickness 60-80 microns). The Pole shall be provided with Graphite grey/ Anthracite grey/ Black as standard colour options Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities Make of LEDs - LEDs of CREE/ LUMINOUS/ OSRAM / SEOUL / SAMSUNG/ LUMILED/ NICHIA/CITIZEN, the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of material CE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-charge. Make: K-Lite/ Unilamp / Havells and Phillips or Equivalent. 103 Supply and installation of 70W LED Spot beam light, Integral control gear, should be maximumu Dimension : Ø210 x 216 x 268 Mounting: Surface ProductFinish: Grey IP: 65/66, should be made from Pressure Die-Cast Aluminium and toughened glass, Luminaire should be capable8° / 12° / 24° / 40° / 60 ° / 40°x11°. Should have different options in beam angles, Luminaire should be complete with driver and capable of operating at line voltage of 100-270 Vac, 50Hz with PF of >0.9, Fixture should be capable to operate at ambient temperature range of -20-to +40°C and should be IP65 and IK07, LED life of L70 B10 60,000 H. Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities Make of LEDs -LEDs of CREE/ LUMINOUS/ OSRAM/ SEOUL/ SAMSUNG/ LUMILED/ NICHIA/ CITIZEN, the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of materialCE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-charge. Make: K-Lite/ Unilamp / Havells and Phillips or Equivalent. 104 Supply and installation of IP rating IP67, Linear grazer Input power : 10W, 2700K, 3000K, 4000K24Vdc CRI >80 MacAdam step 3 Dimension not more than 1010 x 17 x 9mm Beam angle: 120° Electronic driver ON/OFF (External driver), High-Grade aluminum & Endcaps, Polyurethane Encapsulation diffuser. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire >60,000 hours at 40°C. Operating ambient temperature range is from -25°C to +55°C. Must be operated with 24V DC External Driver efficiency >85%, power factor >0.90, Surge protection 3KV. Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities Make of LEDs -LEDs of CREE/ LUMINOUS/ OSRAM/ SEOUL/ SAMSUNG/ LUMILED/ NICHIA/ CITIZEN, the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of materialCE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval fromEngineer-in-charge. Make: K-Lite/ Unilamp / Havells and Phillips or Equivalent. 105 Supply and installation of Static White 3000K surface mounted compact spot light designed to provide directional light. Beam angle 15°/ 25°/ 40°. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive A2 stainless steel fasteners. Clear toughened glass of 4mm thickness. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Power consumption should be between 10W to 12W at steady state full intensity luminaire should have minimum luminous flux of 1054 Lm. Color rendering index CRI ≥ 80 and power factor of complete luminaire ≥ 0.90, at white colour. Swivel range of 0° - 90°. Single cable entrance M10 cable gland. Protection class IP-66. Mechanical resistance IK06. marine grade coating graphite grey / anthracite grey / jet black. Available colour temperature 3000K/ 4000K, Colour rendering index (CRI)>80. SDCM-3 MacAdam. LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire 113 x 84 x 117mm. Adequate heat sink with proper thermal management shall be provided. Operating Temperature: -10°C to +50 C, Operating Humidity : 10%-90%. THD should be less than 10%. Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities Make of LEDs -LEDs of CREE/ LUMINOUS/ OSRAM/ SEOUL/ SAMSUNG/ LUMILED/ NICHIA/ CITIZEN, the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of materialCE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval fromEngineer-in-charge. Make: K-Lite/ Unilamp / Havells and Phillips or Equivalent. 106 Supply and instllation of 9W/m encapsulated silicon flex, should be at least IP 67 3000K 24Vdc CRI >80 MacAdam step 3 Beam angle: 120°, Should be equipped with dot less homogenous lighting effect Electronic driver ON/OFF (External driver) Material Characteristics: Copper coated strip, Silicone moulded diffuser, End cap,Clip. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 50,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >70%, Power factor >0.80, Surge protection 3KV. Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities Make of LEDs -LEDs of CREE/ LUMINOUS/ OSRAM/ SEOUL/ SAMSUNG/ LUMILED/ NICHIA/CITIZEN, the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of materialCE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Architect and Engineer-in-charge. Make: K-Lite/ Unilamp / Havells and Phillips or Equivalent. 107 Supply and installation of Customised narrow spot light of 6-8W LED, should be available in LED colors 3000K, 4000K, 6000K 24Vdc CRI >80 MacAdam step 5, should have maximum Dimension of 65 x 55 x 99mm and with beam angle of 2°, IP rating 66, Made from Die Cast Aluminium Alloy. Toughened clear glass diffuser. SS fasteners. Aluminium mounting bracket for surface mounting on ground. Toughened Clear glass diffuser and optical to reduce glare controlled. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Must be operated with 24V DC External Driver efficiency >85%, power factor >0.90, Surge protection 3KV. Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities Make of LEDs -LEDs of CREE/ LUMINOUS/ OSRAM/ SEOUL/ SAMSUNG/ LUMILED/ NICHIA/ CITIZEN, the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of materialCE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval fromEngineer-in-charge. Make: K-Lite/ Unilamp / Havells and Phillips or Equivalent. 108 Supply and installation of IP rating IP67 linear wall washer. Input power: 20W, 2700K, 3000K, 4000K 24Vdc CRI >80 MacAdam step 3 Dimension not more than 1005x 25x 32mm Beam angle : 30/60° Electronic driver ON/OFF (External driver), High-grade aluminum & Endcaps, Polyurethane Encapsulation diffuser. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire >60,000 hours at 40°C. Operating ambient temperature range is from -25°C to +55°C. Driver efficiency >85%, Surge protection 3KV. and before the supply of materialCE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval fromEngineer-in-charge. Make: K-Lite/ Unilamp / Havells and Phillips or Equivalent. 109 Bought Out Items 110 Designing, providing, fabrication and placing Sand Stone 3-seater Bench placed on ground including base/ foundation as per approval. The stone should be carved using CNC machine. Before execution, the agency shall submit shop drawings with all necessary details. Mock-up at site shall be put as per approved shop drawing. Final execution shall be done as per tested and approved mock-up. All complete as per approved drawing, sample and directed by Architect and Engineer-in-charge. (refer reference drg.) 111 Designing, providing, fabrication and placing dustbin of SS 304 having an outer frame in SS finish fixed to the ground and drum made of 4mm thick sheet fixed on pivot over the outer frame. Drum finish is matt from outside and polished from inside. High proformance rust proof treated outer wall with invisible seamless welded. Sand stone of 100 mm thick fixed at bottom of the frame. Placed over the hard firm base. The dustbins with the complete framework and with all necessary hardware, brackets, clits, base, etc. all complete shall be fixed over the pedestal. Before execution, the agency shall submit shop drawings with all necessary details. Mock-up at site shall be put as per approved shop drawing. Final execution shall be done as per tested and approved mock-up. All complete as per approved drawing, sample and directed by Architect and Engineer-in-charge. (refer reference drg.) 112 Supply installation, testing and commissioning of Water ATM/ Purified Water Vending Machine Power Supply- AC 220V 50Hz/ AC 110 V 60 Hz- Production capacity 3000 GPD- Water Tank capcity- 200 L- UV power- 20 W- Ozone capacity- 1000 mg, Filling Flow Rate- 8 L/min-Selling Method- IC card coins paper note, Size of filling bottle- 200 ml, 500 ml,1L, 2L,20Ltr ( at a time in one tap), Filteration step- 9 steps, Size- L80 cmxW68 cmxH200 cm, Packing-Carton for FCL or Poly wood case for LCL, 19 inch for adertisement LCD panel, Reverse Osmosis (RO), Ultra Violet (UV) Technology, Ozonation Water chiller LED Technology. All complete including over head water tank, base of Kiosk and shed with foundation as per approval of Architect and Engineer-in-charge. 113 SUB HEAD -I ELECTRICAL PANELS:FEEDER PILLAR FEEDER PILLAR-01 (IP-67) INCOMER: MCCB 415V, 50Hz, 100A, 4P, 25kA for 1 sec rated thermal magnetic based MCCB with inbuilt LSIG protection- 1 Nos. Indication lamps LED type phase indication lamps suitable for 230V,50Hz AC (red, yellow, blue) - 1 Set.LED type Indication lamps for breaker, suitable for 230V,50Hz AC supply (on, off, trip) - 1 set With Photo Sensor/LUX Sensor + Timer With Astronomical Switch. BUS-BAR- Busbar (1 Set - 4P + E)Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 150 A, 25 kA for 1 sec of required length and cross sectional area. OUTGOINGS: MCB18Nos. 415V, 50Hz, 25A, DP, 10 kA MCB.24Nos. 415V, 50Hz, 32A, DP, 10 kA MCB. Feeder Pillar as described above 114 SUB HEAD- II : EARTHING -Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 115 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 116 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 117 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. 118 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe From earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. 119 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 120 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 121 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 122 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 123 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 124 SUB HEAD- III : CABLE & CABLE TERMINATION- Supplying following 1.1kV grade, heavy duty XLPE insulated, FRLS type armoured /Unarmured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete as required. 3.5C x 50 sqmm A2XFY 125 3C x 6 sqmm 2X 126 3C x 4 sqmm 2X 127 1C x 4 sqmm 2XY 128 Supplying and making end termination with brass compression gland and cuppor lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3½ X 50 sq. mm (35 mm) 129 Supplying and making end termination with aluminium lugs for following size of aluminium conductor cable of 1.1 kV grade as required. 3C X 6sq. Mm 130 3C X 4sq. mm 131 SUB HEAD-IV:CIVIL WORK - Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) 132 90 mm dia (OD-90 mm & ID-76 mm nominal) 133 Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 134 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 80 m :All Kinds of Soil.Pipes, cables etc., exceeding 80mm dia but not exceeding 300mm dia 135 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150 mm diameter 136 200 mm diameter 137 250 mm diameter 138 300 mm diameter 139 Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) with RCC Top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20mm nominal size) foundation concrete 1:4:8 mix ( 1 cement :4 coarse sand: 8 graded stone aggregate 40 nominal size), inside plastering 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand),finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80 cm and 50 cm deep including perforated C.I. / RCC cover with frame (Heavy duty) 455x610 mm internal dimensions. 140 Inside size 120x90 cm and 90 cm deep including C.I./RCC cover with frame (heavy duty) 560 mm internal diamete 141 Providing & fixing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per I.S:10910 on 12 mm dia steel bar conforming to I.S:1786 having minimum cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 165 mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturers permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15cm cement concrete block 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size) complete as per design. 142 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 300 to 350 mm diameter 143 For pipes 250 to 300 mm diameter 144 Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.4 145 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 500x700 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design. Dimensions 500x700 mm & 45 cm deep for pipe line with one or two inlets. With common burnt clay F.P.S. (non modular) bricks of class designation 7.4 146 GST Extra as applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
TenderDetail
Loading tenders