View Bid Results For Down Comer Tenders

We found 120 Bid Results related to down comer tenders. You can find Contractor details who won down comer tenders along with contract details in Bid awards announcements section.

Filters
Stage
78
27
15
Tender Publishing Platform
12
108
State / UT
22
33
17
16
10
7
6
5
5
3
3
2
2
2
1
1
1
1
1
1
1
1
1
Contract Value
47
22
40
11
Publish Date
0
0
0
0
0
Sector
20
50
16
11
7
6
6
4
4
2
2
2
2
1
1
1
1
1
1
1
1
Ownership
5
72
23
12
9
4
Within keyword
Active filters:
Showing 1–3 of 120 tenders matching your filters
1.
Health and Family Welfare #11383742 AOC
Supply Of Furniture Items To Government Medical College At Suryapet In Suryapet District.=150 Student Cot With Mattress & Pillow 1 Scope: This Specification Is For The Requirement Of Iron Cots Suitable For General Purpose In Hospitals. 1.1 Dimensions 2.1 Over All Dimensions Of Cot Of Size Top Frame ( Sheet ) Shall Be Length 1910 Mm, Width 910 Mm And Height 470 Mm With Bushes. 2.2 The Various Tubes Used In Manufacture Of Iron Cots Should Have The Following Outside Diameter And Thickness. Component Outside Dia ( Mm ) Thickness ( Mm ) A Bows Outer Cr Tubes -38.10.Mm X 1.60Mm B Cross Tubes Cr Tubes 25.40 Mm X 1.22 Mm C Filling Tubes Cr Tubes 19.05 Mm X 1.22 Mm 2.3 The Ms Flat For Top Shall Be Inside All Four Sides Of Size 50X3 Mm Minimum Thickness Of 3.0 Mm. 3 Material: 3.1 Frame Work Shall Be Of Cr Sheets Conforming To Is: 513 D Quality. 3.2 Bows & Tubes: These Shall Be Made From Cr Steel Tubes. 3.3 Shoes: These Shall Be Manufactured From Pvc / Hard Rubber Bush. Nominal Height Of The Shoe Shall Be 35 Mm. Outside Dimensions Of 3Mm. 4 Manufacture 4.1 Head End: Construction Of The Head End Shall Comply To Meet Requirement Given 4.2 Bows Shall Be Manufactured From Steel Tubes. It Shall Be Bent, With Inside Radius Of Not More Than 125 Mm At Top 2 Corners Cr Sheet Brackets . Bracket Of 3 Mm Thickness, Shall Be Welded With The Bows Vertical Upright Members Which Allows Frame To Rest On It An 4.3 Cross Tube: One Horizontal Cross Tube For Making The Structure Of The Bow Rigid Shall Be Welded Between The Vertical Upright Members Of The Bows. Cross Tube Shall Be Welded Below The Sleeping Level At A Height Of 200 Mm From The Bottom. 4.4 Filling Tubes: The Three Vertical Filling Tubes Shall Be Welded To The Cross Tube And To The Bow. They Should Be Spaced At Regular Intervals. The Height Of The Head End Bow Shall Be About 610 Mm. 4.5 Foot End Bow: It Shall Be Similar To 4.1.1 To 4.1.3 Except Leg Bows, Which Shall Be Of 570 Mm Height. 4.6 Mattress Platform: This Shall Comply With The Requirements Given Below:- The Bed Frame Shall Be Made From C.R. Sheet Double Bent. It Should Be Reinforced With Three Formed Channels To Size 20 X 50 X 50 X 50 X 20 Mm Of 1.25Mm Thickness Flanges Welded Inside The Length Wise. With 3 Years Warranty Finish As Per General Condition Of Tender 100 Almarah Steel Full Size Multi Bend Construction And Inter Locking Design And Full Length Over Lapping Doors And Side. Three Way Bolting Mechanism. Spot Welding &Ark Welding. Anticorrosion Treated Components. Dimensions Outer: 1980 H X 910 W X 480 D Mm Main Door With Shetters Top, Bottom Lh & Rh Sides, Shelves And Back All Materials Thickness Not Less Than 1 Mm Almariahs To Be Provided With 4 Full Fixed Shelves Of Inside With 5 Compartments. Shelve Size 908 X 430 Mm Crca Steel: Cold Rolled Close Annealed Steel Used For Thickness 0.6 To 1.0 Mm Range As Per Is-513 1994 ( Reaffirmed In1998 ) . Grade ‘D’ Or ‘Dd’ Quality. Chemical Composition, Tensile Properties, Bend Test, Surface, Flatness, Hardness As Per Is-513 1994. Hot Rolled Steel Used For Thickness 2.0 To 3.15 Mm Range As Per Is-1079 1994 Is-1079 1994 ‘D’ Quality Or Is-10748 1995 Grade-Ii. Chemical Composition, Tensile Properties, Bend Test, Surface Flaws, Roll Mark, Dent & Lines Etc. Weight 80 Kgs Finished General Condition With 3 Years Warranty Finish As Per General Condition Of Tender 100 Chairs For Office 1. Seat / Back Assembly: The Seat And Back Are Made Up Of 1.2 ±0.1Cm. Thick Hot-Pressed Plywood Measured And Upholstered With Fabric Upholstery Covers And Moulded Polyurethane Foam. The Back Foam Is Designed With Contoured Lumbar Support For Extra Comfort. The Seat Has Extra Thick Foam On Front Edge To Give Comfort To Popliteal Area. The Chair Is Available In Three Models. Mid Back Size 47.5 Cm. ( W ) X 58.0 Cm. ( H ) *Pch-9U01rg / 9U02rg / 9U12rg Seat Size 47.0 Cm. ( W ) X 48.0 Cm. ( D ) 2. High Resilience ( Hr ) Polyurethane Foam: The Hr Polyurethane Foam Is Moulded With Density = 45±2 Kg / M3 And Hardness Load 16 ± 2 Kgf As Per Is:7888 For 25% Compression. 3. Armrests: The One-Piece Armrests Are Injection Moulded From Black Co-Polymer Polypropylene. 4. Center Tilt Synchro Mechanism ( For 9U01rg / 9U02rg ) : The Mechanism Is Designed With The Following Features: · 360° Revolving Type. · 3 Position Locking · Tilt Tension Adjustment 5. Tubular Frame ( For 9U12rg ) : The Powder Coated ( Dft 40-60 Microns ) Tubular Frame Is Cantilever Type & Made Of Ø 2.54 ±0.03Cm. X 0.2 ±0.016Cm.Thk. M.S. Er.W. Tube. 6. Pneumatic Height Adjustment ( For 9U01rg / 9U02rg ) : The Pneumatic Height Adjustment Has An Adjustment Stroke Of 12.0 ±0.3Cm. 7. Telescopic Bellow Assembly ( For 9U01rg / 9U02rg ) : The Bellow Is 3-Piece Telescopic Type And Injection Moulded In Black Polypropylene. 8. Pedestal Assembly ( For 9U01rg / 9U02rg ) : The Pedestal Is Injection Moulded In Black 33%Glass-Filled Nylon And Fitted With 5 Nos. Twin Wheel Castors. The Pedestal Is 66.3 ±0.5Cm. Pitch-Centre Dia. ( 76.3 ±1.0Cm With Castors ) . 9. Twin Wheel Castors ( For 9U01rg / 9U02rg ) : The Twin Wheel Castors Are Injection Moulded In Black Nylon. Overall Dimensions Of Chair Width ( W ) : 76.3 Cm. Depth ( D ) : 76.3 Cm. Height ( H ) : 85.5-97.5 Cm. Seat Height ( Sh ) : 42.5-54.5 Cm Of Featherlite / Godrej Or Equavalent As Directed By The Engineer-In-Charge. 50 Teachers Classroom Table Lecture Table Size: 1500 L X 600 D X 750 Ht System: Angular Legs Specification: Table Top: 25Mm Thick Pre-Laminated Particle Board Finished With 2Mm Pvc Edge Banding On All Exposed Edges. Under Structure: Ms Powder Coated Switch Angular 40X40 Legs And Ms Powder Coated Cross Beams ( 40X20 ) Of Featherlite / Godrej Or Equavalent As Directed By The Engineer-In-Charge.. 250 Examination Hall Table 1 Dimensions: 750 Mm X 450 Mm X 750 H Mm 2 Material : 2.1 A ) Plb / Plt – Top 2.2 Impregnated Base 18Mm Thickness With 2Mm Thick Hot Pressed Pvc Beading 2.3 C ) Under Structure : This Table Comes With A Square Tube Under Structure With Prime Quality C.R Tube Steel. 3 All Steel Tubes Used For Desk Under Structures Are As Per Is-3601-1984, Is- 7138-1973, Is-4923-1985. 4 Top Frame And Legs :30 X 30 C.R Square Tube 1.2Mm Thickness With One Foot Steps. 5 These Shall Be Manufactured From Pvc Bush. Nominal Height Of The Shoe Shall Be 35 Mm. Outside Dimensions Of 3Mm With 3 Years Warranty Finish As Per General Condition Of Tender 120 Lecture Hall Dual Desk Bench For ( 2 ) Students Genii 2Strfr+Rr Plt Choco Sm6 1240 X 1130 X 757 Desk-Top Panel-All Panels Are Made From 18Mm Thk Pre-Laminated Twin Board ( E1 / P2 Grade ) With Pvc Edge Banding On All Sides.The Panels Have Cornersrounded For Safety Usage. Understructure - All Side Metal Frames And Cross Connectors Are Made From Combination Of 25.4 X1.2 Mm Thk ( Approx. 18 Swg ) Round Erw Tubes , 31.8 X 1.2 Mm Thk ( Approx. 18 Swg ) Round Erw Tubes And 28.6 X 1.2 Mm Thk ( Approx. 18 Swg ) Round Erw Tubes ( As Per Is:7138 ) Which Are Welded Together.The Welded Structures And Cross Connectors Are Coated With Min. 45 Micron Thickness Of Epoxy Polyester Coating.Back Supports Which Are Provided At The Rear Back Are Made Of 50.8 X 25.4 X 1.2 Mm Thk ( Approx. 18 Swg ) Rectangular Erw Tubes ( As Per Is:7138 ) .The Tubes Are Coated With Min. 45 Micron Thickness Of Epoxy Polyester Coating.The Storage Shelves Are Made From 0.6 Mm Thk Ms Sheet ( As Per Is:513 ) Fixed Below The Radesk Top Panel And Are Coated With Min. 45 Micron Thickness Of Epoxy Polyester Coating. Hooks Are Provided On The Vertical Side Frames On Both Sides Of The Desk For Hanging Bags / Bottles. They Are Made From 2 Mm Thk Ms Sheet ( As Per Is:513 ) And Are Coated With Min. 45 Micron Thickness Of Epoxy Polyester Coating.The Understructure Is Assembled Using M6 Trilobular Screws ( As Per Din 7500 ) With Zn Blue Plating.Compact Laminate Seat And Back Panels Are Assembled Using M6 Counter Sunk Trilobular Screws ( As Per Din 7500 ) With Zn Black Plating ( As Per Is 1573:1986 ) Spacers Are Provided On Th Top Of Round Tubes For Wooden Panels Fixing. They Are Made Of Made Glass Filled ( 30% ) Plastic Caps Made Of Pp Copolymer ( 3530 Grade ) Are Also Provided On The Rear Frames Adding More Aestheic Value To The Product.M6 High Tensile Tvs Make Bolt ( Class 8.8 ) With Glasss Filled Nylon Level Adjustors Are Provided At The Bottom Of Understructure To Take Care Of Unevenness In Floor With Height Adjustment Of Approx 15Mm Of Featherlite / Godrej Or Equavalent As Directed By The Engineer-In-Charge.. 25 Table ( Office Table Big Size ) 1 Dimensions:1450 W X 680 D X 750 H ( In Millimetres ) 2 Material: 2.1 A.Plb / Plt - Top 25 Mm Thickness. 3 All Plb And Plt ( Prelaminated Twin ) Is Of Following Grade. 4 Grade Ii Type Ii – Designation – Plb-22 ( As Per Is: 12823 – 1990 ) 5 Each Plb / Plt May Contain Following Material Layers: 6 Particle Board, Top With 2Mm Thick Hot Pressed Pvc Beading With Keyboard Moulded Type. 7 C. Under Structure: This Table Should Be Square Cr Tube 30 X 30 Under Structure With Prime Quality C.R Steel Square Tube 1.22Mm Thickness. 8 D. Storage: 3 Draw & 2 Draw Metal Is Provided For Storage. One Side 2 Draw And Other Side 3 Draw Metal Shall Be Provided. 9 Drawer: • Box-Box-File : Dimensions 390 W X 430 H X 560 D Mm, Construction & Material:Welded Assembled, Crca As Per Is-513.• Back , Sides, Top & Bottom , Box 0.6 Think. Drawer Tray & Front- 0.8 Mm. Crca As Per Is-513 , Drawer Slides Used Must Be Of Heavy Duty Telescopic Channels 10 All Steel Metal Components Are Manufactured From Finest Quality Steel, Which Conforms As Per Is-513 Grade D, Dd 11 All Steel Tubes Used For Desk Under Structures Are As Per Is-3601 – 1984, Is-7138-1973, Is-4923-1985. 12 Shoes - These Shall Be Manufactured From Hard Rubber Or Pvc And Shall Be Uniform In Texture And Chemically Inactive To The Action Of Mild Acids. The Nominal Height Of The Shoes, Shall Be 35Mm. With 3 Years Warranty Finish As Per General Condition Of Tender 500 Student Study Table 1 Study Table Of Size 1200 Mm X 600Mm X 750Mm Having Wood Laminate Finish The Table Top / Work Surface: Made From 25Mm Thick Plb With Pvc Lipping. Side Panels: Made From 18Mm Thick Plt With Pvc Lipping. Modesty Panel: Made From 18Mm Thick Plt With Pvc Lipping. Neat Wiring Flow With Cut-Outs On Both Sides, Free Standing Pedestal For Adequate Personal Storage. 2 Material: 3 A.Plb / Plt - Top 25 Mm Thickness. 4 All Plb And Plt ( Prelaminated Twin ) Is Of Following Grade. 5 Grade Ii Type Ii – Designation – Plb-22 ( As Per Is: 12823 – 1990 ) 6 Each Plb / Plt May Contain Following Material Layers: 7 Particle Board, Top With 2Mm Thick Hot Pressed Pvc Beading With Keyboard Moulded Type. 8 C. Under Structure: This Table Should Be Square Cr Tube 30 X 30 Under Structure With Prime Quality C.R Steel Squre Tube 1.22Mm Thickness. 9 D. Storage: Single Drawer Is Provided For Storage With Right Side With Metal Shall Be Provided. 10 Drawer: • Box-Box-File : 550 X 420 X 390, Construction &Material:Welded Assembled, Crca As Per Is-513.• Back , Sides, Top & Bottom , Box 0.6 Thick. Drawer Tray & Front- 0.8 Mm. Crca As Per Is-513 , Drawer Slides Used Must Be Of Heavy Duty Telescopic Channels 11 All Steel Metal Components Are Manufactured From Finest Quality Steel, Which Conforms As Per Is-513 Grade D, Dd 12 All Steel Tubes Used For Desk Under Structures Are As Per Is-3601 – 1984, Is-7138-1973, Is-4923-1985. 13 Shoes: These Shall Be Manufactured From Pvc / Hard Rubber Bush. Nominal Height Of The Shoe Shall Be 35 Mm. Outside Dimensions Of 3Mm. 14 Finish As Per General Condition Of Tender With 3 Years Warranty Finish As Per General Condition Of Tender 60 3 Seater Visitor Chair Supply Of Orbit 3 Seater Visitors Chair, *Cushioned Seat And Back *Silver Grey Finish With Arms Model No. Sj-708La Of Featherlite / Godrej Or Equavalent As Directed By The Engineer-In-Charge. With 3 Years Warranty Finish As Per General Condition Of Tender 200 Almarah Steel Full Size Multi Bend Construction And Inter Locking Design And Full Length Over Lapping Doors And Side. Three Way Bolting Mechanism. Spot Welding &Ark Welding. Anticorrosion Treated Components. Dimensions Outer: 1980 H X 910 W X 480 D Mm Main Door With Shetters Top, Bottom Lh & Rh Sides, Shelves And Back All Materials Thickness Not Less Than 1 Mm Almariahs To Be Provided With 4 Full Fixed Shelves Of Inside With 5 Compartments. Shelve Size 908 X 420 Mm Crca Steel: Cold Rolled Close Annealed Steel Used For Thickness 0.6 To 1.0 Mm Range As Per Is-513 1994 ( Reaffirmed In1998 ) . Grade ‘D’ Or ‘Dd’ Quality. Chemical Composition, Tensile Properties, Bend Test, Surface, Flatness, Hardness As Per Is-513 1994. With 3 Years Warranty Finish As Per General Condition Of Tender 200 Open Rack 1 Steel Slotted Angular Racks, Open Type With 6 Shelves Making 5 Compartments Of Size 1800Mm X 900Mm X 450 Mm, Cr Sheet Shelfs 1.2Mm Thickness With An Angle Of 2 Mm Thickness And Size: 40 Mm X 60 Mm, With 8 Corner Brackets Of 2 Mm Thickness. 2 Finish: Sheet Metal Components: All Dents, Burrs And Sharp Edges Shall Be Removed From The Various Components. The Components Shall Be Individually Pickled, Scrubbed And Rinsed To Remove Grease, Rust, Scale Or Any Other Foreign Element. Immediately After Pickling, All The Mild Steel Parts Shall Be Given Phosphate Treatment Conforming To Class C Or Is : 3618-1966. 3 The Process For Application Of Phosphate Coating Shall Be In Accordance With Is: 6005-12970. Two Coats To Enamel Paint ( Colour Grey Is Preferred ) Shall Then Be Applied As Follows: Finish Coat With Enamel Paint Conforming To Is : 151-1950, Is : 2932-1974 Or Is : 2933-1975. In The Case Of Stoving Enamel The Components Shall Thereafter Be Backed At A Specified Temperature In An Over Heated Uniformly. The Finish Shall Be Smooth And Uniform With A Hard And Touch Film Of Enamel, Strongly Adhering To The Surface. The Finish Shall Be Free From All Visible Defects And Shall Not Chip When Tapped Lightly With A Dull Pointed Instrument. Note: Putty Shall Be Applied To All The Surfaces Requiring Filling And Shall Conform To Is: 110-1968. 4 Tests: The Performance Tests Required For The Finished Racks Shall Be Carried Out As Per The Methodology Mentioned In The Is 6189:1985. The Rack Shall Have A Name Plate Or Label Fixed To It Showing The Manufacturer’S Name, Initials Or Recognized Trademark. 5 Hospital Furniture Items Shall Be Subjected To Tests In Accordance With The Requirements Of Relevant Specifications. However, The Painted Furniture Items Shall Also Satisfy The Adhesion Test And In Addition Satisfy The Performance Test Give Below: 6 Shoes: These Shall Be Manufactured From Pvc / Hard Rubber Bush. Nominal Height Of The Shoe Shall Be 35 Mm. Outside Dimensions Of 3Mm. With 3 Years Warranty Finish As Per General Condition Of Tender 25 Dining Table With Benches Supply Of Dining Table, Specification: Size 93 L X 30W X 30H With 8 Seater, Top In 18 Gauge Of 304 Grade Stainless Atell , Legs In 1 1 / 2 X 1 1 / 2 Square Tube Stainless Stell In 16 Gauge Of 304 Grade With Foldable Benches As Directed By The Engineer-In-Charge. With 3 Years Warranty Finish As Per General Condition Of Tender 25 Library Table Size: 1800 X 900X 750 Mm The Understructure Should Be Available In Cr Square Tube. It Should Be Fixed And Shall Accommodate 6 People The Table Top Should Be 25 Mm Thick Pre Laminated Particle Board With Teak Wood Beading 40 Mm Thickness With Polish Top Frame And Legs Crs Quare Pipe 40X40 Mm, 1.6 Mm Thickness With 6 Legs Two Support Footrust With 35 H X 3Mm Pvc Bush. With 3 Years Warranty Finish As Per General Condition Of Tender 5 Principal Table Supply Of Cabin Table, Main Table Of Size 2400 L X 900 D X 750 Ht, Side Composite Storage Unit Size 1350 L X 450 D X 750 Ht, System - Enrich Series. Specifications: Table Top: 25Mm Thick Pre-Laminated Particle Board With 2Mm Pvc Edge Lipping On All Exposed Edges. Under Structure: Supported On Chrome Plated Enrich Legs Supporting On Ms Powder Coated Cross Beams ( 40X20 ) . Modesty Panel: 18Mm Thick Plt Modesty Panel Of 450Mm Ht. Wire Management: Anodised Finish 350 X 150 Flip Up Box With Soft Closures, Without Sockets And Switches Are Provided, Pvc Cable Dump & Vertical Wire Entry Cover For Wire Uptake From Floor To Cable Tray. Storage Unit Top - 25Mm Thick Pre Laminated Particle Board With 2Mm Pvc Edge Lipping. Body, Shelfs & Shutters – 18Mm Thick Pre Laminate Particle Board With 2Mm Pvc Edge Lipping. Back – 9Mm Thick Pre Laminate Particle Board With 2Mm Pvc Edge Lipping. Lock - Regular Lock. Handle - Finger Grooves Hardware – Door Closing Hinges, Mini-Fix, Levellers & Locks, Etc., Of Featherlite / Godrej Or Equavalent As Directed By The Engineer-In-Charge. 5 Executive Chair For Principal Pulse Hb Mb Seat, Adj. Arms Larger Seats Head Rest 1.Seat / Back Assembly: The Seat Is Made Up Of 1.5 ± 0.1Cm Thk. Hot Pressed Plywood Measured. The Back Is Made Up Of Injection Moulded Glass Filled Polypropylene & Upholstered Using Net Fabric With High Tenacity Yarn. *Seat Size ( Larger Seat Depth ) { Pulsal } : 47.0 Cm. ( W ) X 51.5 Cm. ( D ) *Back Size ( Pulsax, Pulsal ) : 45.0 Cm. ( W ) X 65.3 Cm. ( H ) 2.High Resilience ( Hr ) Polyurethane Foam: The Hr Polyurethane Foam Is Moulded With Density =55+ / -2 Kg / M3 And Hardness 16 ± 2 Kgf As Per Is:7888 For 25% Compression. 3.Armrests ( Adjustable ) { Pulsax, Pulsal } : The Adjustable Armrest Is Designed With The Following Features: •Up-Down Adjustment- 6 Steps ( 7.2 ± 0.5Cm Range ) •Armrest Top Is Mounted On Armrest Structure Made Of Glass Filled Nylon. •Armrest Top Is Pu Moulded Over Glass Filled Nylon Insert. 4.Lumbar Support Assembly: The Lumbar Support Consists Of Polypropylene Pad.The Height Of Lumbar Pad Can Be Adjusted Through Two Projecting Knobs Provided On The Rear Side Of The Pad. Lumbar Pad Has An Adjustment Of 8.0 ± 0.5 Cm In Height. 5.Front Pivot Synchro Mechanism: The Adjustable Tilting Mechanism Is Designed With The Following Features. •360° Revolving Type. •Single Point Control. •Front-Pivot For Tilt With Feet Resting On Ground Ensuring More Comfort. •Tilt Tension Adjustment. •4-Position Locking With Anti-Shock Feature. •Seat / Back Tilting Ratio Of 1:2. 7.Pneumatic Height Adjustment: The Pneumatic Height Adjustment Has An Adjustment Stroke Of 10.0 ± 0.3 Cm. 8.Pedestal Assembly: The Pedestal Is Injection Moulded In Black 30% Glass-Filled Nylon And Fitted With 5 Nos. Twin Wheel Castors. The Pedestal Pitch-Center Dia Is 066.1 ± 0.5 Cm. ( 76.1 ± 1.0 Cm. With Castors ) . 9.Twin Wheel Castors: The Twin Wheel Castors Are Injection Moulded In Black Nylon. Overall Dimensions Of Chair Width ( W ) : 76.1 Cm Depth ( D ) : 76.1 Cm Height ( H ) : 98.0 - 108.0 Cm Seat Height ( Sh ) : 45.8 - 55.8 Cm. Neckrest : The Neckrest Assembly Consist Of Polypropylene Pad With Moulded Polyurethane Foam & Covered With Polyester Fabric Neckrest Is Fixed To Back Assembly Through Neckrest Connector Neckrest Assembly Has Height Adjustment Of4.2 + 0.5 Cm And Rotation Adjustment Of Overall76”+ 2”. The Complete Neckrest Assembly Is Retro Fit To The Main Chair Of Featherlite / Godrej Or Equavalent As Directed By The Engineer-In-Charge. 50 Alamarah With Acrylic ( Glass ) Door 1. Multi Bend Construction And Inter Locking Design And Full Length Over Lapping Doors And Side. Three Way Bolting Mechanism. Spot Welding & Co2 Welded. Front Side Doors With Acrylic Transparent Sheet All Round Frame 70 Mm Borders Thickness 5.5 Mm Thickness 2. Dimensions Outer: 1980 H X 910 W X 480 D Mm 3. A. Top, Bottom, Lh & Rh Sides And Back Material Thickness- 1 Mm 4. B. Removable Rh & Lh Main Doors With Stiffeners Material Thickness =1.22 Mm 5. Almariahs To Be Provided With 4 Full Fixed Shelves Of Inside Shelve Size Of 908 W X 420 D Of Thickness -1 Mm 6. Cr Steel: 7. Cold Rolled Close Annealed Steel Used For Thickness 0.6 To 1.2 Mm Range As Per Is-513 1994 ( Reaffirmed In 1998 ) . Grade ‘D’ Or ‘Dd’ Quality. Chemical Composition, Tensile Properties, Bend Test, Surface, Flatness, Hardness As Per Is-513 1994. 8. Finish As Per General Condition Of Tender With 3 Years Warranty Finish As Per General Condition Of Tender 25 Office Table With Draws ( Office Table Small Size ) 1. Dimensions:1200 W X 600 D X 750 H Mm 2. Material: 2.1 A.Plb / Plt - Top 25 Mm Thickness. 3. All Plb And Plt ( Prelaminated Twin ) Is Of Following Grade. 4. Grade Ii Type Ii – Designation – Plb-22 ( As Per Is: 12823 – 1990 ) 5. Each Plb / Plt May Contain Following Material Layers: 6. Particle Board, Top With 2Mm Thick Hot Pressed Pvc Beading With Keyboard Moulded Type. 7. Under Structure: This Table Should Be Square Cr Tube 30 X 30 Under Structure With Prime Quality C.R Steel Square Tube 1.22Mm Thickness. 8. D. Storage: 3 Draw Is Provided For Storage. With Right Side With Metal Shall Be Provided. 9. Body For Storage Units: Body And Draws For Storage Unit Dimensions 390 W X 430 H X 560 D Mm Shall Be Made From Cr Steel Sheet Not Less Than 0.8 Mm Thick With Heavy Duty Telescopic Channels. This Shall Be Bent To Box Shape From One Piece And Tack Welded At Final Overlapped Comer Or Assembled With A Maximum Of Two Pieces Properly Welded 10. All Steel Metal Components Are Manufactured From Finest Quality Steel, Which Conforms As Per Is-513 Grade D, Dd 11. All Steel Tubes Used For Desk Under Structures Are As Per Is-3601 – 1984, Is-7138-1973, Is-4923-1985. 12. Shoes - These Shall Be Manufactured From Hard Rubber Or Pvc And Shall Be Uniform In Texture And Chemically Inactive To The Action Of Mild Acids. The Nominal Height Of The Shoes, Shall Be 35Mm. With 3 Years Warranty Finish As Per General Condition Of Tender 200 Office Chairs S Type With Armrest ( Nursing Station ) Supply Of Class Room Chair And Hostel Room Study Chair, Cushioned Seat & Plastic Back Without Arms & With Powdercoated Legs With Bushes, Magna Va - Plastic ( Pc ) Of Featherlite / Godrej Or Equavalent As Directed By The Engineer-In-Charge. With 3 Years Warranty Finish As Per General Condition Of Tender 3 Examination Couch Examination Table On Ratchet With No Storage Overall Dimension Of L 1830Mm X W 600Mm X H 850 Mm. The Backrest Has Ratchet Mechanism For Tilting The Backrest. Leg Frames & Intermediate Frames Is Made Of Erw Tubes Having Section Of 30 X 30 Square Tubes With Thickness Of 1.6Mm. Nylon 6 Leg Shoes Is Given To Avoid Wear & Tear. Ms Sheet Metal Lying Surface Of Thickness 1.2Mm Is Used. Top Sheet Metal Panel Base Frame Of 25 X 25 Erw Square Tubes Of Thickness 1.6Mm Is Used. Ratchet Is Of Ms Strip With Section 40 X 4 To Provision The Backrest Tilt. All Ms Part Are Pre Treated And Powder Coated With Ral White Color & All Plastic Parts In Grey. Safe Working Load Is 135Kg Of Featherlite / Godrej Or Equavalent As Directed By The Engineer-In-Charge. 500 Student Chair With Pad Royal Visitor S Type Pad Chair Cushion Seat And Back Cushion Foam And Quality Moulded Ply With Pu Handles With 1 Hr Round Pipe 16 Gauge With Fabric With 18 Mm Pre-Laminated Writing Pad. All Hr Pipes Section Are Shall Be Pre-Treated And Epoxy Powder Coated 50-60 Microns Thickness With 3 Years Warranty Finish As Per General Condition Of Tender
Contract Date: Ref. Documents Contract Value : 1.31 Crore
Government Departments No of Bidders 1
2.
Petroleum and Natural Gas #11337544 AOC
Bids Are Invited For Custom Bid For Services - Pre-Ta Exchanger And Miscellaneous Equipment Job--1 1.A. Blinding And Deblinding - Rate Per 2 1.C. Blinding And De-Blinding With Using 3 1.D. Gasket Repacement 4 1.F. Gasket Repacement Using Torque Wren 5 1.G. Bolt Servicing Upto 12 Dia Flanges 6 1.H. Bolt Servicing Above 12 Dia Flange 7 1.I. Bolt Servicing From 24 Dia Flanges 8 1.M. Bolt Servicing Upto 12 Dia Flanges 9 1.N. Bolt Servicing Above 12 Dia Flange 10 1.O. Bolt Servicing From 24 Dia Flanges 11 1.S. Opening Of Flange Using Flange Spre 12 1.T Blind Fabrication 13 1.Y. Bolts Cutting With Hacksaw/Grinding 14 2.A. Piping - Cs Fillet Joint Per Inch D 15 2.D. Piping - As/Ss Fillet Joint (Smaw) 16 2.E. Piping - As/Ss Fillet Joint (Tig) 17 2.J. Piping - Cs Butt Joint X Ray Qualit 18 2.M. Piping - As/Ss Butt Joint (Tig) 19 2.Aa. Grit Blasting 20 2.Bb. Primer Painting - Inorganic Zinc S 21 2.Cc. Painting - For Insulated Pipe Havi 22 2.Dd. Painting - For Insulated Pipe Havi 23 2.Ee. Manual Cleaning Of Pipelines 24 3.A. Dye Penetrant Test , Rate Per Inch 25 3.C. Dye Penetrant Test , Rate Per Sq Me 26 3.D. Wfmpt, Rate Per Inch Dia Of Wfmpt D 27 4.A. Radiography On Piping With Iridium 28 4.D. Radiography On Piping With Selenium 29 5.A. Stress Relieving Done Using Electri 30 7.A. Overlay Patch Work (Rate Per Sq.Foo 31 7.B. Overlay Patch Work (Rate Per Sq.Foo 32 8.A. Inlay Patch Work - Cs Inlay Patch P 33 8.B. Inlay Patch Work - Ss Inlay Patch P 34 9. Replacement Of Casing Plates 8 Mm Thk 35 10.A. Weld Build Up Cs – Upto 500 Sq Inc 36 10.B. Weld Build Up Cs – From 501 Sq Inc 37 10.C. Weld Build Up Cs – From 1001 Sq In 38 10.D. Weld Build Up Cs – From 1501 Sq In 39 10.E. Weld Build Up Cs – Above 2000 Sq I 40 10.F. Weld Build Up As / Ss (All Varieti 41 10.G. Weld Build Up As / Ss (All Varieti 42 10.H. Weld Build Up As / Ss (All Varieti 43 10.I. Weld Build Up As / Ss (All Varieti 44 10.J. Weld Build Up As / Ss (All Varieti 45 10.K. Weld Build Up Dss/Sdss – Upto 500 46 10.L. Weld Build Up Dss/Sdss – From 501 47 10.M. Weld Build Up Dss/Sdss – From 1001 48 10.N. Weld Build Up Dss/Sdss – From 1501 49 10.O. Weld Build Up Dss/Sdss – Above 200 50 10.P. Weld Build Up Monel/Inconel – Upto 51 10.Q. Weld Build Up Monel/Inconel – From 52 10.R. Weld Build Up Monel/Inconel – From 53 10.S. Weld Build Up Monel/Inconel – From 54 10.T. Weld Build Up Monel/Inconel – Abov 55 10.U. Weld Build Up With Hpcl Supplied E 56 10.V. Weld Build Up With Hpcl Supplied E 57 10.W. Weld Build Up With Hpcl Supplied E 58 10.X. Weld Build Up With Hpcl Supplied E 59 10.Y. Weld Build Up With Hpcl Supplied E 60 10.Z. Weld Build Up Alloy 59 / Alloy 28 61 10.Aa. Weld Build Up Alloy 59 / Alloy 28 62 10.Bb. Weld Build Up Alloy 59 / Alloy 28 63 10.Cc. Weld Build Up Alloy 59 / Alloy 28 64 10.Dd. Weld Build Up Alloy 59 / Alloy 28 65 10.Ee. Weld Build Up Jobs (Structural) - 66 10.Ff. Replacement Of Anode-Soft Iron 67 10.Gg. Replacement Of Anode- Ss [All Var 68 11.A. Fillet Weld Run - Cs Weld Run With 69 11.B.Fillet Weld Run - Ss Weld Run With 70 11.C. Fillet Weld Run - Ss Weld Run Wit 71 11.D. Fillet Weld Run - Monel Weld Run W 72 11.E. Butt Weld Run - Cs Weld Run With E 73 11.F.Butt Weld Run - Ss Weld Run With E- 74 11.G. Butt Weld Run - Ss Weld Run With 75 11.H. Butt Weld Run - Monel Weld Run Wit 76 12.A.System Scaffolding - Upto 6 Mtr. Fr 77 12.B.System Scaffolding -Above 6 Mtr. N 78 12.C. System Scaffolding -12.C. System S 79 12.D. System Scaffolding - Inside The Fu 80 12.E. System Scaffolding - Inside The Fu 81 12.F. System Scaffolding - Inside The Fu 82 12.G. Stack Scaffolding - Applicable For 83 13. Cement Lining Repairs Of Vessels. Ra 84 14. Repair & Replacement Of Ss Perforate 85 15. Cement Lined Pipe Replacement, Rate 86 16. Fabrication Of Pipie Fabricated Redu 87 17.A Cement Lining Of Straight Pipes , R 88 17.B Cement Lining Of Straight Pipes , R 89 17.C Cement Lining Of Elbows / Mitres, T 90 17.D Cement Lining Of Elbows / Mitres, T 91 17.E. Cement Lining Touch Ups 92 22.A. Dropping And Reinstallation Of Rel 93 22.B.Servicing N Testing Of Psvs, Rate P 94 23.A. Level Gauge Servicing. Rate Payabl 95 23.B Level Gauge Servicing. Rate Payable 96 23.C. Level Gauge Servicing. Rate Payabl 97 25.A. Replacement Of Channel Section Cs 98 25.B. Replacement Of Channel Section Ni- 99 25.C. Replacement Of Channel Section As/ 100 25.D. Replacement Of Channel Section Dss 101 26. Replacement Of Liner Plates(3 Mm Thk 102 27.A. Cold Compound Application ; Suppl 103 27.B. Cold Compound Application ; Suppl 104 27.C. Cold Compound Application ; Suppl 105 27.D. Cold Compound Application ; Suppl 106 27.E. Cold Compound Application ; Suppl 107 27.F. Cold Compound Application ; Suppl 108 27.G. Cold Compound Application ; Suppl 109 27.H. Cold Compound Application ; Suppl 110 27.I. Cold Compound Application For Valv 111 27.J. Cold Compound Application On Corro 112 28.A. Complete Re - Tubing Of Exchangers 113 28.B. Complete Re - Tubing Of Exchangers 114 28.C. Complete Re-Tubing Of Exchangers A 115 28.D. Partial Re-Tubing Of Exchangers An 116 28.E. Partial Re-Tubing Of Exchangers An 117 28.F. Partial Re-Tubing Of Exchangers An 118 28.G. Partial Re-Tubing Of Exchangers An 119 28.H. Cage Assembling During Re-Tubing O 120 28.I. Rerolling Of Exchanger Tubes; Cs T 121 28.J. Rerolling Of Exchanger Tubes; As / 122 28.K. Rerolling Of Exchanger Tubes; Non- 123 29.A. Exchanger Machining: Machining Of 124 29.B. Exchanger Machining: Machining Of 125 29.C. Exchanger Machining: Machining Of 126 29.D. Exchanger Machining: Machining Of 127 29.E. Exchanger Machining: Machining Of 128 29.F. Exchanger Machining: Machining Of 129 29.G. Exchanger Machining: Machining Of 130 29.H. Exchanger Machining: Machining Of 131 29.I. Exchanger Machining: Machining Of 132 29.J. Exchanger Machining: Machining Of 133 30.A. In-Situ Orbital Machining, Up To 1 134 30.B In-Situ Orbital Machining, Above 12 135 30.C. In-Situ Orbital Machining, Above 4 136 30.D. In-Situ Milling Of Exchanger Compo 137 31.A. Exchanger / Vessel Pneumatic Test 138 31.B. Repeat Shell Test- Up-To 45 Shell 139 31.C. Repeat Shell Test- Above 45 Shell 140 31.D. Tube Test Of Exchanger – Up To 45 141 31.E. Tube Test Of Exchanger - Above 45 142 31.F. Repeat Shell Test And Tube Test – 143 31.G. Repeat Shell Test And Tube Test - 144 31.H. Dropping, Gasket Replacement And R 145 31.I. Dropping, Gasket Replacement And R 146 31.J. Floating Head Gasket Replacement ( 147 31.K. Floating Head Gasket Replacement ( 148 31.L. Channel Section/Shell Cover Droppi 149 31.M. Channel Section/Shell Cover Droppi 150 31.N. Back Shell Test - Upto 45 Shell I 151 31.O. Back Shell Test - Above 45 Shell 152 31.P. Back Shell Test - Above 45 Shell 153 31.Q. Back Shell Test - Upto 45 Shell I 154 31.R. Arresting Exchanger Gasket Leak - 155 31.S. Arresting Exchanger Gasket Leak - 156 31.T. Arresting Exchanger Gasket Leak - 157 31.U. Repeat Bundle Removal And Insertio 158 31.V. Repeat Differential Tesitng Of Hig 159 31.W. Complete Overhauling Of Lube Oil C 160 31.X. Complete Overhauling Of Exchanger 161 31.Y. Complete Overhauling Of Exchanger 162 31.Z. Complete Overhauling Of Exchanger 163 31.Aa. Complete Overhauling Of Exchanger 164 31.Bb. Bolts Servicing Of Exchanger Comp 165 31.Cc. Bolts Servicing Of Exchanger Comp 166 31.Dd. Bolts Servicing Of Exchanger Comp 167 31.Ee. Bolts Servicing Of Exchanger Comp 168 31.Ff. Overhauling Of Cover Type Air Fin 169 31.Gg. Overhauling Of Single Plug Type A 170 31.Hh. Overhauling Of Double Plug Type A 171 32. Hydrotest Of Loops.Rate Per Inch Dia 172 33.A.Lumpsum Rate For Inspection Test Pi 173 33.B. Lumspsum For Inspection Test Pit E 174 34. Suction Strainer Cleaning. Rate Paya 175 35. Dropping N Re-Installation Of Contro 176 36.A. Tray /Down Comer/Seal Pan Replacem 177 36.B.Tray/Down Comer/Seal Pan Fabricatio 178 36.C. Replacement Of Column Wear Plate / 179 37.A Dropping Or Reinstallation Of Valve 180 37.B. Hydrotest Of Valve -Rate Per Inch 181 38. Hydrojet Cleaning Of Exchanger Bundl 182 39.A. Insulation Jobs - Removal Of Old I 183 39.B. Insulation Jobs - Provide 3 Inspe 184 39.C. Insulation Jobs - Provide 6 Inspe 185 39.D. Insulation Jobs - Thorough Cleanin 186 39.E. Insulation Jobs - Supply And Paint 187 39.F. Insulation Jobs - Supply And Fixin 188 39.G. Insulation Jobs - Supply And Fixin 189 39.H. Insulation Jobs - Supply And Fixin 190 39.I. Insulation Jobs - Supply And Fixin 191 39.J. Insulation Jobs - Supply And Fixin 192 39.K. Insulation Jobs - Supply N Fix New 193 39.L. Insulation Jobs - Supply N Fix New 194 39.M.Remove, Supply N Fixing Of Rope Ins 195 39.N.Remove , Supply N Fixing Of Rope In 196 39.O.Remove , Supply N Fixing Of Rope In 197 39.P.Remove, Supply N Fixing Of Rope Ins 198 39.Q. Insulation Jobs -Provide Moisture/ 199 39.R. Insulation Jobs - Cold Insulation 200 39.S. Insulaiton Jobs - Cold Insulation 201 40.A. Supply Of 110Kv Dg Set, Rate Payab 202 40.B. Supply Of Diesel Air Compressor, R 203 41.A Jobs On Manpower Basis (Rate Per 8 204 41.B. Jobs On Manpower Basis (Rate Per 8 205 41.C Jobs On Manpowerbasis (Rate Per 8 H 206 41.D. Jobs On Manpower Basis (Rate Per 8 207 41.E. Jobs On Manpower Basis (Rate Per 1 208 41.F. .Jobs On Manpowerbasis (Rate Per 8 209 41.G.Jobs On Manpower Basis (Rate Per 8 210 41.H. Jobs On Manpowerbasis (Rate Per 8 211 41.I. Jobs On Manpowerbasis (Rate Per 8 212 41.J. Jobs On Manpowerbasis (Rate Per 8 213 42.A. Valve Servicing, Per Inch Dia Of V 214 42.B. Valve Servicing,Per Inch Dia Of Va 215 43.A. Seal Welding Of Cs Exchanger Tube. 216 43.B. Seal Welding Of As/Ss Exchanger Tu 217 43.C. Seal Welding Of Dss/Sdss Exchanger 218 43.C. Seal Welding Of Non Ferrous Exchan 219 44.A. Additional Hydrojet Cleaning Of Af 220 44.B. Additional Afc Plug Removal N Fixi 221 45.A. Seal Welding Of Afc Plugs (Tig) - 222 45.B. Seal Welding Of Afc Plugs (Tig) - 223 45.C. Seal Welding Of Afc Plugs (Tig) - 224 45.D. Seal Welding Of Afc Plugs (Tig) - 225 45.E. Seal Welding Of Afc Plugs (Tig) - 226 46.A. Constant Load / Variable Load Spri 227 46.B. Constant Load / Variable Load Spri 228 46.C. Constant Load / Variable Load Spri 229 46.D. Constant Load / Variable Load Spri 230 46.E. Constant Load / Variable Load Spri 231 46.F. Constant Load / Variable Load Spri 232 47. Flushing Of Lines With Any Liquid Me 233 48. Carboard Blasting Of Lines - Per Bla 234 49.A. Ndt, Dcsect Of Exchanger Tubes, Th 235 49.B. Ect Of Exchanger Tubes, The Rate P 236 49.C. Rvi Of Equipments, The Rate Payabl 237 50.A. Overhauling Of Vessels Upto And E 238 50.B. Overhauling Of Vessels From 2 M3 239 50.C. Overhauling Of Vessels From 10 M3 240 50.D. Overhauling Of Vessels From 25 M3 241 50.E. Overhauling Of Vessels From 50 M3 242 50.F. Overhauling Of Vessels Above 100 243 50.G. Hydrotest Of Vessels 244 51.A. Overhauling Of Columns Upto And Eq 245 51.B. Overhauling Of Columns From 30 M3 246 51.C. Overhauling Of Columns From 70 M3 247 51.D. Overhauling Of Columns From 200 M3 248 51.E. Overhauling Of Columns From 400 M3 249 51.F. Overhauling Of Columns Above 800 M 250 52. Overhauling Of Filters 251 53.A. Media Unloading, Sieving And Loadi 252 53.B. Stenciling On Spent Catalyst Drums 253 53.C. Supply Of Polythene Liner Bags For 254 54.A. Opening / Closing Of Equipment Man 255 54.B. Opening / Closing Of Equipment Man 256 54.C. Opening / Closing Of Equipment Man 257 55.A Hiring Of Additional Mobile Crane-1 258 55.B Hiring Of Additional Forklift-3 Ton 259 55.C Hiring Of Additional Trailer-20 Fee 260 55.D. Hiring Of Additional Jeep / Pickup 261 55.E. Hiring Of Additional Mini Tractor 262 55.F. Hiring Of Mobile Crane On Monthly 263 55.G. Hiring Of 20Ft Tractor Trailor / 2 264 55.H. Hiring Of Hydrojetting Machine Wit 265 56. A. Driving Services Inside Refinery 266 56.B. Supply Of Office Attendant To Main 267 55.E. Hiring Of Additional Mini Tractor 268 55.F. Hiring Of Mobile Crane On Monthly 269 55.G. Hiring Of 20Ft Tractor Trailor / 2 270 55.H. Hiring Of Hydrojetting Machine Wit 271 56.A. Support Services To Maint Tpd 272 56.B. Support Services For Ta Units
Contract Date: Ref. Documents Contract Value : 2.94 Crore
Boards / Undertakings / PSU No of Bidders 3
Andhra Pradesh View Result →
3.
Public Administrative Department #11325176 AOC
Tender For Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Achitrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead: (Dsr No. 15.12) , Of Area 3 Sq. Metres And Below (Dsr No. 15.12.1) , Dismantling Of Flushing Cistern Of All Types (C.I./Pvc/Vitrious China) Including Stacking Of Useful Materials Near The Site And Disposal Of Unsericeable Materials Within 50 Metres Lead. (Dsr No. 15.52) , Dismantling W.C. Pan Of All Sizes Including Disposal Of Dismantled Materials Including Malba All Complete As Per Directions Of Engineer-In-Charge. (Dsr No. 14.82) , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres Lead. (Dsr No. 15.56) , 6 Mm Cement Plaster 1:3 (1 Cement : 3 Fine Sand) Finished With A Floating Coat Of Neat Cement And Thick Coat Of Lime Wash On Top Of Walls When Dry For Bearing Reinforced Cement Concrete Slabs And Beams. (Dsr No. 13.17) , Disposal Of Buidling Rubbish/ Malba/ Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved. (Dsr No. 15.60) , Dismantling G.I. Pipes (External Work) Including Excavation And Refilling Trenches After Taking Out The Pipes, Manually/ By Mechanical Means Including Stacking Of Pipes Within 50 Metres Lead As Per Direction Of Engineer-In-Charge: (Dsr No. 15.44) , 15 Mm To 40 Mm Nominal Bore (Dsr No. 15.44.1) , Dismantling Stone Slab Flooring Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead. (Dsr No. 15.25) , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window, Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Tuch Ups, Including Rubbing, Curing, Moulding And Polishing Of Edges To Give High Gloss Finish Etc. Complete At All Levels (Dsr No. 8.2) , Granite Stone Slab Of Colour Black, Cherry/Ruby Red (Dsr No. 8.2.2) , Area Of Slab Over 0.50 Sqm (Dsr No. 8.2.2.2) , Regarding Terracing Of Md Phaska Covered With Tiles Or Brick, In Cement Mortar By Dismantling Tiles Or Bricks, Removing Mud Plaster, Preparing The Surface Of Mud Phaska To Proper Slope, Relaying Mud Plaster Gobri Leaping And Tiles Or Bricks, Grouted In Cement Mortar 1:3 (1 Cement : 3 Fine Sand), Including Replacing Unserviceable Tiles Or Bricks With New Ones And Disposal Of Unseviceable Material To The Dumping Ground (The Cost Of The New Tiles Or Brick Excluded), All Complete As Per Direction Of Engineer-In-Charge (Dsr No. 14.13) , 12 Mm Cement Plaster Of Mix: (Dsr No. 13.1) , 1:4 (1 Cement: 4 Fine Sand) (Dsr No. 13.1.1) , Painting Top Of Roofs Wih Bitumen Of Approved Quality @ 17Kg Per 10 Sqm Impregnated With A Coat Of Coarse Sand At 60 Cudm Per 10 Sqm, Including Cleaning The Slab Surface With Brushes And Finally With A Piece Of Cloth Lightly Soaked In Kerosene Oil Complete: (Dsr No. 12.15) , With Residual Type Petroleum Bitumen Of Grade Vg- 10 (Dsr No. 12.15.1) , Flush Pointing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement For Flat Tile Bricks On Top Of Mud Phaska (Dsr No. 14.18) , With F.P.S. Brick Tiles (Dsr No. 14.18.1) , Providing Gola 75X75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10 Mm And Down Gauge), Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : (Dsr No. 12.21) , In 75X75 Mm Deep Chase (Dsr No. 12.21.1) , Making Khurras 45X45 With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size) Over P.V.C. Sheet 1 M X 1M X 400 Micron, Finished With 12 Mm Cement Plaster 1:3 (1 Cement : 3 Coarse Sand) And A Coat Of Neat Cement, Rounding The Edges And Making And Finishing The Outlet Complete. (Dsr No. 12.22) , Providing And Fixing Pvc Door Frame Of Size 50X47 Mm With A Wall Thickness Of 5 Mm (± 0.2 Mm), Made Out Of Single Piece Extruded Pvc Profile, With Mitred Cut Joints And Joint With 2 Nos. Of Pvc Bracket Of Size 190 Mm X 100 Mm Long Arms Of Cross Section Size 35 X 15 Mm & Self Driven Self Self Taping Screws, The Vertical Door Profiles To Be Reinforced With 40X20 Mm M.S. Rectangular Tube Of 0.8 Mm, Including Providing Epdm Rubber Gasket Weather Seal Throughout The Frame, Including Jointing 5 Mm Pvc Frame Strip With Pvc Solvent Cement On The Back Of The Profile. The Door Frame To Be Fixed To The Wall Using 8 X 100 Mm Long Anchor Fasteners Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. (Dsr No. 9.141) , 35 Mm Thick Factory Made Solid Panel Pvc Door Shutter, Made Out Of Single Piece Extruded Solid Pvc Profiles, 5 Mm (± 0.2 Mm) Thick, Having Styles & Rails (Except Lock Rail) Of Size 95 Mm X 35 Mm X 5 Mm, Out Of Which 75 Mm Shall Be Tapered (On Both Side), Having One Side Thickness Of 15 Mm Integrally Extruded On The Hinge Side Of The Profile For Better Screw Holding Power, Including Reinforcing With Ms Tube Of Size 40 Mm X 20 Mm X 1 Mm, Joints Of Styles & Rails To Be Mitered Cut & Joint With The Help Of Pvc Solvent Cement, Self Driven Self Tapping Screws & M.S. Rectangular Pipes Bracket Of Size 190 Mm X 100 Mm Of Cross Section Size 35 Mm X 17 Mm X 1 Mm At Each Comer, Single Piece Extruded 5 Mm Thick Solid Pvc Lock Rail Of Size 115 Mm X 35 Mm, Out Of Which 75 Mm To Be Flat And 20 Mm To Be Tapered At Both Ends, Having 15 Mm Solid Core In Middle Of Rail Section Integrally Extruded, Fixing The Styles & Rails With Thehelp Of Solvent And Self Driven Self Tapping Screws Of 125 Mm X 11 Mm, Including Providing 5 Mm Isngle Piece Solid Pvc Extruded Sheet Inserted In The Door As Panel, All Complete As Per Manufacturers Specialization And Direction Of Engineer-In-Charge (Dsr No. 9.142) , Decorative Finish (Wood Grained Finish) (Dsr No. 9.142.2) , Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, Including Making Food The Walls Etc. Concealed Pipe, Including Painting With Anti Coorosive Bitumasic Paint, Cutting Chases And Making Good The Wall : (Dsr No. 18.11) , 20 Mm Dia Nominal Bore (Dsr No. 18.11.2) , Providing And Placing On Terrace (At All Floor Levels) Polythylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. (Dsr No. 18.48) , Providing And Fixing Ist Quality Ceramic Glazed Wall Tile Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Coloures, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Enigneer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cment : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm, Includign Pointing In White Cement Mixed With Pigment Of Matching Shade Complete (Dsr No. 8.31) , Providing And Laying Polished Granite Stone Flooring In Required Desing And Patterns, In Linear As Well As Curvilinear Portions Of The Building Al Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing, And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge (Dsr No. 11.56) , Polished Grantie Stone Slab Of Colour Black, Cherry/Ruby Red Or Equivalent (Dsr No. 11.56.1) , Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete (Dsr No. 13.88) , Distempering With Ist Quality Acrylic Distemper (Ready Mixed) Having Voc (Volatile Organic Compound) Contents Less Than 50 Gram/Litre, Of Approved Brand And Manufacturer Including Applying Additional Coats Wherever Required To Achieve Even Shade And Colour (Dsr No. 13.81) , Old Work (One Or More Coats) (Dsr No. 13.81.1) , Finishing Walls With Textured Exterior Paint Of Required Shade: (Dsr No. 13.111) , Old Work (One Or More Coat Applied @ 1.67 Ltr/ 10 Sqm) On Existing Cement Paint Surface (Dsr No. 13.111.1) , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100 Mm Sand Cast Iron P Or S Trap, Including Flush Pipe, With Manually Controlled Device (Handle Lever) Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: (Dsr No. 17.1) , White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests (Dsr No. 17.1.1) , Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, Including Flush Pipe, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: (Dsr No. 17.2) , W.C. Pan With Isi Marked White Solid Plastic Seat And Lid (Dsr No. 17.2.1) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380X350 Mm With White Pvc Automatic Flushing Cistern, With Fittings, Standard Size C.P. Brass Flush Pipe, Spreaders With Unions And Clamps (All In C.P. Brass) With Waste Fitting As Per Is : 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fittings And Cutting And Making Good The Walls And Floors Wherever Required: (Dsr No. 17.5) , Single Half Stall Urinal With 5 Litre P.V.C. Automatic Flushing Cistern (Dsr No. 17.5.1) , Providing And Fixing Urinal Partition 10Mm Thick High Stainless Steel Of Siz 1.5 X 2.75 Fixed In Position With Clams Holding The Steel Partition. All Exposed Edges To Be Grinded With Smooth Finish To The Entire Satisfaction Of Engineer-In-Charge Including Carriage Of Material To Site Of Work, To The Entire Satisfaction Of Engineer-In-Charge Including Carriage Of Material To Site Of Work (Fixed On Slopping Back Wall Before Fixing Ceramic Tiles) (Nsi) , Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: (Dsr No. 17.7) , White Vitreous China Flat Back Was Basin Size 550X400 Mm With Single 15Mm C.P. Brass Pilar Tap (Dsr No. 17.7.4) , Extra Over And Above Item No. 17.7.4 Of Dsr (Sr. No. 29) For Using Under Counter Washbasin Of Size 550 X 445 X 190 Mm As Per Archtechural Drawings, Code X0494 Or Parryware (Niagara) Model With Auto Closing Piller Cock System Code G 2013A 1 Of Parry Ware (Lapis Neo) With Adustable Brackets (Special For Under Counter) To Entire Satisfaction Of Engineer-In-Charge. (Nsi) , Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. (Dsr No. 17.31) , Providing And Fixng 8 Mm Dia C.P./ S.S. Jet With Flexible Tube Upto 1 Metre Long With S.S. Triangular Plate To Eureopean Type W.C. Of Quality And Make As Approved By Engineer-In-Charge (Dsr No. 17.16A) , Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. (Dsr No. 17.28) , Semi Rigid Pipe (Dsr No. 17.28.1) , 32 Mm Dia (Dsr No. 17.28.1.1) , Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms. (Dsr No. 17.71) , Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. (Dsr No. 17.73) , 450 Mm Towel Rail With Total Length Of 495 Mm, 78 Mm Wide And Effective Height Of 88 Mm, Weighing Not Less Than 170 Gms. (Dsr No. 17.73.1) , Providing And Fixing Toilet Paper Holder: (Dsr No. 17.34) , C.P. Brass (Dsr No. 17.34.1) , Providing And Fixing C.P. Brass Bib Cock Of Approved Quality Conforming To Is:8931: (Dsr No. 18.49) , 15 Mm Nominal Bore (Dsr No. 18.49.1) , Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms. (Dsr No. 18.51) , 15 Mm Nominal Bore (Dsr No. 18.51.1) , Providing And Fixing Ball Valve (Brass) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete: (Dsr No. 18.18) , 18 Mm Nominal Bore (Dsr No. 18.18.2) , Providing And Fixing Grab Rail Of Stainless Steel Pipe 1-1/4 And Fitting Of Grade Aisi 304 As Per Jis Standard 3448 Including Fitting And Fixing Or Pipe With Clamps At 1.00 M Spacing Including Cutting And Making Good The Walls Complete As Per Direction Of Engineer-In-Charge. (Nsi) , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is: 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete. (Dsr No. 9.97) , 200X10 Mm (Dsr No. 9.97.3) , Providing And Fixing Aluminium Hanging Floor Door Stopper, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is: 1868) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete. (Dsr No. 9.101) , Twin Rubber Stopper (Dsr No. 9.101.2) , Providing And Fixing Of Superior Quality Heavy Duty Isi Marked Sanitary Napkin Vending Machine, Incinerator, Battery And Happy Days Pad Complete In All Respects (Nsi) , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required (Dsr No. 10.25) , In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Work (Dsr No. 10.25.2) , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete (Dsr No. 13.80) , Providing And Fixig Square-Mouth S.W. Gully Trap Clss Sp-1 Complete With C.I. Grating Brick Masonry Chamber With Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside) The Weight F Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design: (Dsr No. 19.4) , 100X100 Mm Size P Type (Dsr No. 19.4.1) , With Commom Burnt Clay F.P.S. (Non Modular Bricks Of Class Designation 7.5 (Dsr No. 19.4.1.1) , Providing And Laying Cement Concrete 1:5:10 (1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) All-Round S.W. Pipes Including Bed Concrete As Per Standard Design: (Dsr No. 19.2) , 150 Mm Diameter S.W. Pipe (Dsr No. 19.2.2) , Making Connection Of Drain Or Sewer Line With Existing Manhole Including Breaking Into And Making Good The Walls, Floors With Cement Concrete 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Cement Plastered On Both Sides With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Finished With Floating Coat Of Neat Cement And Making Necessary Channels For The Drain Etc. Complete: (Dsr No. 19.21) , For Pipes 100 To 250 Mm Diameter (Dsr No. 19.21.1) , Providing And Fixing In Position Pre-Cast Reinforced Cement Concrete Manhole Cover And Frame Of Required Shape And Approved Quality. (Dsr No. 19.19) , L D- 2.5 (Dsr No. 19.19.1) , Rectangular Shape 600X450 Mm Internal Dimensions (Dsr No. 19.19.1.1) , Providing And Fixing Soap Dispensor And Fitting Complete In All Respects (Nsi) , Providing And Fixing Acralicsheet With Silver Remark Engraving Plate 12X18 In Position At Required Place To The Entire Satisfaction Of Engineer-In -Charge (Nsi) , Providing And Fixing Sun Board Printing With Lamination On 5Mm Sun Board Of Size 6 X 2 To Be Fixed At The Height Of 12 From Ngl, Leveled In Position To The Entire Satisfaction Of Engineer-In-Charge (Nsi) , Providing And Fixing Acrylic Sheet Of With Silver Remark Engraving Plate 12 X 12 In Position At Required Place To The Entire Satisfaction Of Engineer-In-Charge (Nsi) , Providing And Fixing Sun Board Printing With Lamination On 5Mm Sub Board Of Size 24 X 30 To Be Fixed At The Height Og 12 From Ngl, Leveled In Position To The Entire Satisfaction Of Engineer-In-Charge (Nsi) , Providing And Fixing 50 Watt Led Flood Light With Bracket Out Side On The Wall Complete In All Respects (Nsi) , Providing And Fixing Of Crompton Greeves 1 Hp Water Pump With Help Of Fasterners To Be Fixed At Site As Per Entire Satisfaction Of Engineer-In-Charge (Nsi) , Providing, Fixing And Installation Of Inverter With Battery Of Minimum Back Up Of 8 Hours Including The Cost Of Wiring, Switches Board Etc. Complete In All Respect To The Entire Satisfaction Of Iec Inverter (With 2 Year Warranty Period) Make Microtek/V-Guard/Luminious.Battery 12V/500H Tubular Battery Make Exide/Microtek/Luminious Etc (With 3 Year Warranty Period (Nsi) , Providing And Fixing Of 1.5 Mm Single Core Pvc Insulated Copper Cable For Wiring At Toilet Block. (Nsi) , Providing And Fixing Of 0.75 Mm Single Core Pvc Insulated Copper Cable For Earthing At Toilet Block (Nsi) , Providing And Fixing Of Led Round Concealed Light Complete Set Type 15 W Make: Crompton/Havells (Nsi) , Supplying And Fixing Metal Box Of Following Sizes (Nominal Size) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Painting Etc. As Required (Nsi) , 75 Mm X 75 Mm X 60 Mm Deep (Nsi) , 100 Mm X 100 Mm X 60 Mmm Deep (Nsi) , 150 Mm X 150 Mm X 60 Mmm Deep (Nsi) , Supplying And Fixing Following Piano Type Switch/ Socket On The Existing Switch Box/ Cover Including Connections Etc. As Required (Nsi) , 5/6 Amps Switch (Nsi) , 3 Pin 5/6 A Socket Outlet (Nsi) , Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Mdular Base & Cover Plate For Modular Switches In Respect As Required (Nsi) , 8 Module (125 Mm X 125 Mm) (Nsi) , Supply And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. (Nsi) , 3 Pin 5/6 A Socket Outlet (Nsi) , Providing And Fixing Ceiling Fan 1200Mm (48) Sweep Including All Accessories Complete To Entire Satisfaction Of Eic. Make: Crompton/ Usha/Khaitan/Bajaj (Nsi) , Providing And Fixing Led Tube Light Complete Set Type 36W, 1=4Ft, Make: Philips/Crompton/Havells (Nsi) , Providing And Fixing Of Exhaust Fan Of Double Ball Bearing 12 Sweep Including All Necessary Accessories Complete To Entire Satisfaction Of Eic. Make: Crompton/Havells/Bajaj/Gec (Nsi) , Wiring For Light Point/Fan Point/Exhuast Fan Point/Call Bel Point With 1.5 Sq. Mm. Frls Pvc Insulated Copper Conductor Single Core Cable In Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Singlecore Cable Etc. As Required (Nsi) , Wiring For Light/Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/Recessed Medium Class Pvc Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. (Nsi) , Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. (Nsi) , Double Pole (Nsi) , Supplying And Fixing Metal Box Of Following Sizxes (Nominal Size) On Surface Or Inrecess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Painting Etc As Required. (Nsi) , 200Mm X 150Mm X 100 Mm , Supplying And Fixing Following Modular Switch/Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required (Nsi) , 15/16 Annual Periodical Maintenance Switch (Nsi) , 6 Pin 15/16 Annual Periodical Maintenance Socket Outlet (Nsi) , Supplying And Fixing Following Way, Single Pole And Netural, Sheet Steel, Mcb Distribution Board Consumer Unit 240 Volts, On Surface/Reess, Complete With Timed Copper Bus Bar Netural Bus Bar, Earth Bus Bar, Hinged Front Acrylic Cover For The Mcb Knobs, Detachable Gland Plate, Interconnections, Phosphatized And Powder Painted Including Earthling Etc. As Required (But Without Mc/Pccb/Isolator) 2*4 Way (Nsi) , Note:- The Old Material To Be Recovered From Site Will Be Returned To The Department And Will Be Recorded In M.A.S. Register.
Contract Date: Jun 22, 2026 Contract Value : 3.51 Lakh
Local Bodies No of Bidders 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Himachal Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Himachal Pradesh View Result →
6.
Housing Urban and Rular Development #11060027 Price Bid
Tender for Demolishing Of Cement Concrete Manually & Disposal Of Material Within 50 Metres.Nominal Concrete 1:3:6 Or Richer Mix , Demolishing Of Reinforced Cement Concrete Work Manually Including Stacking Of Steel Bars & Disposal Of Material Within 50 Metres. , Demolishing Of Brick Work Manually Including Stacking Of Servicible & Disposal Of Material Within 50 Metres. In Cement Mortar , Dismantling Of Doors & Windows Frames & Chawkhats Of Area Blow 3 Sqm. , Dismantiling Of Tile Flooring & Roof Laid In Cement Mortar Including Stacking Within 50 Meters For Thickness Above 25Mm To 40Mm , Earth Work In Excavation By Mechanical Means By Hydraulicexcavator )/ Manual Means In Foundation Trenches Or Drains Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 Ratio , Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Sunken Floor Etc., Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering And Finishing: , Providing And Laying Cement Concrete In Kerbs, Steps And The Like At Or Near Ground Level Excluding The Cost Of Centering, Shuttering And Finishing. , Providing And Laying In Position Specified Grade Of Reinforceed Cement Cocrete Excluding The Cost Of Centering, Shuttring, Finishing And Reinforcment - All Work Upto Plinth Level. 1:1.5:3 , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size). , Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level- , Steel Work In Built Up Tubular Trusses Including Cutting And Welding And Applying Primer Coat Of Approved Steel Primer Ad Bolted With Special Shaped Washers. Etc. , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In 1:6 , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In : , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. , Using R4 Series With Frame (115 Mm & Above) X (45 Mm & Above) & Both Glazed And Fly Screen Sash (44 Mm & Above) X (55 Mm & Above) With Zinc Alloy (Zamak) Powder Coated Handle On Every Glazed Panel Along With Multipoint Locking System. (Height Above 1.8M) , Using R2 Series With Frame (39 Mm & Above ) X (39 Mm & Above) & Mullion (39 Mm & Above) X (60 Mm & Above). (Height Upto 1.2 Metre) , Casement Window With Double Rebate Frame With Two Side Hung Glazed Panel And Two Side Hung Wire Mesh Panel And Fixed Mullion With Friction Hinges As Per Size And Weight Of Sash, Multi-Point Locking System, Zinc Alloy (Zamak) Powder Coated Handles On Both Glazed And Fly Screen Panel. , Using R4 Series With Frame (64 Mm & Above) X (55 Mm & Above) & Sash (64 Mm & Above) X (100 Mm & Above) & French (False) Mullion (64 Mm & Above) X (60 Mm & Above). (Height Upto 2.5 Metre). , Casement Door Single Panel With Zinc Alloy (Zamak) 3D Hinges, Multi-Point Locking System With Cylinder, Zinc Alloy (Zamak) Powder Coated Handles On Both Sides. , With 15 Mm Thick Fully Perforated Square/Butt Edge Light Weight Calcium Silicate Panels/ Tiles , With 15 Mm Thick Integral Densified Micro Edge Light Weight Calcium Silicate False Ceiling Tiles , Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side, Grade I, Type Ii Is: 12823 Marked , 12 Mm Thick Plain Grade -1, Medium Density Flat Pressed Three Layer Particle Board With Bwp Type Synthetic Resin Adhesive As Per Is : 848 : , Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length , 12 Mm Thick One Side Pre-Laminated Particle Board (Decorative Lamination On One Side And Other Sides Balancing Lamination) , Decorative Plywood One Side Decorative Veneer And Commercial Veneer On Other Face , Second Class Teak Wood Including Isi Marked Nickel Plated Bright Finished M.S. Piano Hinges With Necessary Screws , Providing Beams Including Hoisting, Fixing In Position And Applying Wood Preservative For The Unexposed Surfaces, Etc. Complete With : , Providing And Fixing 18 Mm Thick, 150 Mm Wide Pelmet Of Coir Veneer Board Isi Marked Is 14842, Including Top Cover Of 6 Mm Coir Veneer Board, Nickle Plated M.S. Pipe 20 Mm Dia. , Providing And Fixing, In Position Concealed G.I. Section For Wall Paneling Using Board Of Required Thickness Fixed On The ‘W Profile , Granite Stone Slab Of All Colour And Texture Except Black, Cherry/Ruby Red Area Of Slab Over 0.50 Sqm , Providing And Laying Vitrified Floor Tiles In Different Sizes With Water Absorption Less Than 0.08% And Conforming To Laid On 20Mm Thick Cement Mortar 1:4 Cement And Matching Pigments Etc., Complete. 600X600 , 1000X1000 , Providing And Laying Vitrified Tiles In Different Sizes With Water Absorption Less Than 0.08 % And Conforming To In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 Jointing With Grey Cement Slurry. , Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete , Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1 :3 And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. , Providing And Laying Of 60Mm Thk Factory Made Cement Concrete Interlocking Paver Blocks M-30 Made Of Block Material With Strong Vibrator Compaction Of Aproved Design & Shape In Required Colour Filling The Line With Sand Etc. , 12 Mm Cement Plaster Of Mix : , 20 Mm Cement Plaster Of Mix : , Providing & Applying White Cement Based Putty Of 2 Mm Thick Of Approved Brand Over Plastered Wall Surface For Even & Smooth Wall Fiinsh , Finishing With Epoxy Paint Two Coats On All Location Prepared And Applied On Steel , Finishing With Epoxy Paint (Two Or More Coats) At All Locations Prepared And Applied As Per ManufacturerS Specifications Including Appropriate Priming Coat, Preparation Of Surface, Etc. Complete , Distempering With 1St Quality Acrylic Distemper (Ready Mixed) Having Voc Content Less Than 50 Gram/Litre, Of Approved Manufacturer And Of Required Shade And Colour All Complete To Achieve Even Shade And Colour , Finishing With Delux Multi Surface Paint For Interiors Using Primer As Specified , Applying Primer Coat , Varnishing With Varnish Of Approved Brand And Manufacture : , French Spirit Polishing , Polishing On Wood Work With Ready Mixed Wax Polish Of Approved Brand And Manufacture : , Providing And Fixing Machine Cut, Mirror/ Eggshell Polished Including Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade, Including Rubbing, Curing, Polishing Etc. , Providing Corrugated G.S. Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Diameter With Bitumen On Overlapping Of Sheets Complete Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Ridges Plain (500 - 600Mm) , Barge Board (Upto 300 Mm) , Gutter .(600 Mm Over All Girth) , Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming . , Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. , Hubless Centrifugally Cast (Spun) Iron Pipes Epoxy Coated Inside & Outside 100Mm , Centrifugally Cast (Spun) Iron Socketed Pipe As Per Is: 3989 , Providing And Filling The Joints With Spun Yarn, Cement Slurry And Cement Mortar 1:2 ( 1 Cement : 2 Fine Sand) In S.C.I./ C.I. Pipes 75 Mm Dia Pipe , 100 Mm Dia Pipe , Providing And Fixing M.S. Holder-Bat Clamps Of Approved Design To Sand Cast Iron/Cast Iron (Spun) Pipe Embedded In And Including Cement Concrete Blocks 10X10x10 Cm Of 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), Including Cost Of Cutting Holes And Making Good The Walls Etc.: For 100 Mm Dia Pipe , For 75 Mm Dia Pipe , Providing And Fixing Bend Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete. 75Mm Bend , Providing And Fixing Plain Bend Of Required Degree. 100Mm , Providing And Fixing Single Unequal Plain Junction Of Required Degree , Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : , 100 Mm Inlet And 75 Mm Outlet , Waste Coupling 38 Mm Dia Of 83 Mm Length And 77Mm Breadth, Weighing Not Less Than 60 Gms , Bottle Trap 38 Mm Single Piece Moulded With Height Of 270 Mm, Effective Length Of Tail Pipe 260 Mm From The Centre Of The Waste Coupling, 77 Mm Breadth With 25 Mm Minimum Water Seal, Weighing Not Less Than 263 Gms , Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms. , Providing And Fixing Ptmt Towel Ring Trapezoidal Shape 215 Mm Long, 200 Mm Wide With Minimum Distances Of 37 Mm From Wall Face With Concealed Fittings Arrangement Of Approved Quality And Colour, Weighing Not Less Than 88 Gms. , Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply 15Mm Dia , 20 Mm Nominal Outer Dia Pipes , Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I/C Making Good The Walls Etc 15 Mm Dia Nominal Bore , 20 Mm Dia Nominal Bore , Providing And Laying Cement Concrete 1:5:10 (1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) All-Round S.W. Pipes Including Bed Concrete As Per Standard Design :150 Mm , 200 Mm Diameter , Providing And Laying Non Pressure Np 2 Class (Light Duty) Reinforced Cement Concrete Pipe With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 (1Cement : 2 Fine Sand ) Including Testing Of Joints Etc. Complete. 150Mm Dia , 250 Mm. Dia. Reinforced Cement Concrete Pipes , Constructing Brick Masonary Road Gully Chamber 50 X 45 X 60Cm With F.P.S. Brick In Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) Including 500 X 450 Mm Pre Cast Reinforced Cement Concrete Horizontal Grating With Frame Complete As Per Standard Design. , Making Connection Of Sewer/Drain Line With Existing Manhole Including Breaking Into & Making Good The Wall, Floors With Cement Concrete 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Cement Plastered On Both Sides With Cement Mortar 1 : 3 (1Cement : 3 Coarse Sand) Finished With A Floating Coat Of Neat Cement And Making Necessary Channels For The Drain Etc. Complete , Providing, Laying, Testing & Commissioning Of C Class Heavy Duty Ms Pipe Conforming To Is 3589/Is 1239 Including Welding, Fittings Like Elbows, Tees, Flanges, Tapers, Nuts Bolts, Gaskets Etc. And Fixing The Pipe On The Wall / Ceiling With Suitable Clamp/Support Frame And Painting With Two Or More Coats Of Synthetic Enamel Paint Of Required Shade Complete As Required : 25 Mm Dia , 65 Mm Dia , 80 Mm Dia , Supplying, Fixing, Testing And Commissioning Of Butterfly Valve Of Pn 1.6 Rating With Bronze / Gunmetal Seat Duly Isi Marked Complete With Nuts, Bolts, Washers, Gaskets Conforming To Is 13095 Of Following Sizes As Required 80 Mm Dia , 65Mm Dia , Supplying, Fixing, Testing And Commissioning Of Butterfly Valve Of Pn 1.6 Rating With Bronze / Gunmetal Seat Duly Isi Marked Complete With Nuts, Bolts, Washers, Gaskets Conforming To Is 13095 Of Following Sizes As Required 80 Mm Dia Supplying And Fixing First-Aid Hose Reel With Ms Construction Spray Painted In Post Office Red, Conforming To Is 884 Complete With The Following As Required. 20 Mm Nominal Internal Dia Water Hose Thermoplastic (Textile Reinforced) Type -2 As Per Is: 12585 20 Mm Nominal Internal Dia Gun Metal Globe Valve & Nozzle. Drum And Brackets For Fixing The Equipmets On Wall. Connections From Riser With 25 Mm Dia Stop Gun Metal Valve & M.S. Pipe And Socket. 40 M , Supplying & Fixing 63 Mm Dia Gun Metal Short Branch Pipe With 20 Mm Nominal Internal Diameter Size Nozzle Conforming To Is 903 Suitable For Instantaneous Connection To Interconnect Hose Pipe Coupling As Required : Gun Metal , Wall Mounted Water Closet Lys-Wht-38851P180ufsm , Vitreous China Lipped Front Urinal Jaguar Urinal, Sensor One Urs-Wht-13255 , Jaguar Counter Top Basin With Fixing Accessories, Mm Fls-Wht-5931 , Jaquar Toilet Paper Holder Recessed Type (Stainless Steel) Cpa-Chr-1153 , Mirror,Of Cera-Cat No. B3530105 , Soap Dish Dispencer,Of Jaguar Cpa-Chr-1135 , Single Lever Extended Basin Mixer Of Jaguar Fus-Chr-29023B , Stop Cock (Concealed) Of Flr-Chr-5053N , Long Nose Bib Cock Of Ari-Chr-39041 , Providing And Fixing Jaguar, Angle Valve For Basin Mixer And Geyser Points Of Opp-Chr-15053Pm Conforming To , Supply & Erection Of Isi Marked Portable Fire Extinguishers, Confirming To Is:15683, Wall Mounted Type, Wall Brackets Complete In All Respect As Per Standard Item With All Accessories, Delivery Hose & Nozzle Whereever Required, Including Fixing On Walls As Per The Directions Of Engineer-In-Charge. (Make : Minimax / Cease Fire / Safex / Safeguard / Ufs) Abc Dry Powder Type 6 Kg. Capacity , Co2 Gas Type. 4.5 Kg. Capacity , Providing & Fixing Of Hand Lever Operated Forged Brass / Cast Steel Body Full Way Ball Valve Type Isolating Valve (Pn 16) Having Ss 316 Ball, Ss Stem, Gland, Spring, Steel Handle With Pvc Grip, Ptef Seat, Screwed Ends Complete. (Make : Cim / Audco / Festo / Advance / Aip) 25 Mm Nominal Bore , Providing & Fixing Air Release Valve With Forged Brass Body Full Way Ball Valve Type Isolating Valve, Flanges / Union, Suitable For Sprinkler / Wet Riser / Down Comer System With All Necessary Connections Complete In All Respects. (Make : Newage / Cim / Leader / Sant) 40 Mm Dia Air Release Valve , Providing And Fixing Standard Fire Hose Cabinet (750 Mm X 1800 Mm X300 Mm) Indoor Type Suitable For Accomodating Internal Hydrant, Hose Reel Made Of Not Less Than 16 Swg Ms Sheet Having Full Fronted Glass Hinged Door (5 Mm Thick Glass) Including Necessary Locking Arrangement With Handle For Housing Two Nos. 15 Meter Long Fire Hose Pipes, 30 Meter Long Hose Reel, Branch Pipe And Hydrant Valve As Required As Per Drawings, Including Brackets For Mounting Accessories, Painting (One Coat Primer And Two Coat Of Fire Red Colour). The Cabinet Shall Be Mounted On Suitable Raised Platform. The Words Fire Hose To Be Painted On The Box.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttarakhand View Result →
7.
Power #11055259 AOC
Tender Document For Sub-Station and Transmission Line [PACKAGE-C8(1B)]-TECHNICALSPECIFICATION FOR 12kV, 800A, 18.4kA, MULTI PANEL (Incoming, Bus Coupler with Adaptor Panel and Outgoing) SHUNT TRIP, INDOOR TYPE SCADA COMPATIBLE SWITCHGEAR WITH MOTOR OPERATED SPRING CLOSING VACUUM CIRCUIT BREAKER- 1 ELECTRICAL PART : 2 WBSETCL Assessed Quantities: 3 245KV 40KA for 3sec Gas Insulated Switchgear - i)2500 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker for line and Transformers & 2500A for Bus coupler Bay iv) CT with current ratio 1600-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification v) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc. vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 4 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 5 LA for Line bay ( one number per phase - to be installed within GIS) 6 CompleteTransformer Bays 7 Buscoupler Bay 8 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 9 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 10 Portable UHF PD monitoring System - The analyser shall have 6 channel input withinherent PD location accuracy of 0.5m., colour display unit and user friendly interface for detailed analysis.The system includes allaccessoriesto monitorPD, UHF cables,required software and other accessories to complete as per Technical Specification. 11 Dew Point Meter as per Technical Specification 12 145KV 31.5KA for 3sec Gas Insulated Switchgear i)2000 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker iv) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc.v) CT with current ratio 1000-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 13 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 14 Complete Transformer Bays for LV side of 160 MVA 220/132 KV Transformer & HV side of 50 MVA 132/33 KV Transformers 15 Bus coupler Bay 16 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 17 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 18 36 KV, 31.5KA for 3sec Indoor, floor mounted drawoutSwitchgear Assembly (2500A Bus rating with Copper Bus Bar) with VCB suitable for EHV cable entry withtripple termination arrangement and bus earthing arrangement from both side, Line earthing arrangement and dead line status and corresponding electrical and mechanicalinterlocking arrangementas per technical specification and requirement comprising of - 19 Outgoing Feeder Bays, 1250A Circuit Breaker ratingas per Techspec. 20 LV side of50MVA 132/33KV Transformer Bays (2000 A Breaker Capacity) CT Ratio 2000-1000/1A 3 coreas per Tech spec 21 HV side of6.3 MVA 33/11KV Transformer Bays(1250 A Breaker Capacity ) as per Tech Spec 22 Station service transformer bay (1250A Circuit Breaker rating) 23 Bus section Bay (2500 A Breaker Capacity) 24 (i)2(two) set of 3 phase Bus PT - 5 limb, (One set each for Main Bus-I & Main Bus-II) with isolation arrangement.as per Tech Spec. (ii) Other required equipment & accessories like Bus Earthing arrangement etc. to complete the system . 25 12 KV, 1600 A, 25 KA, 30 V DC, SCADA compatible, VCB Switchgear includingProtection Relays, ,control & annunciation equipment and other accessories complete as per technical specification (uploaded for Nandanpuronly) Cable and bus earthing shall be electrically and mechanically interlocked with associated breaker as per interlock requirement. but rating should be as per BOQrequirement comprising of - 26 Outgoing Line Bays (CT Ratio 400-200/1) 2 coreVCB rating 1250A 27 Incoming Transformer Bays(CT Ratio 600-400/1A) 4 core VCB rating 1250A 28 Bus section Bay VCB rating 1600A 29 (i) 3(Three) set of 3 phase Bus PTwith isolation arrangement must be mounted above incomer switchgearpanel. (ii) Other required equipment and accessories like Bus earthing arrangement etc to complete the system 30 Electric Overhead Travelling Crane (E.O.T.) 31 Electric Overhead Travelling Crane (E.O.T.)- For 220 KV GIS Building 5.0 Metric Ton capacity or maximum weight of GIS shipping unit whichever is higher -complete with all accessories as per technical specification and requirement. 32 Transformers : 33 160 MVA, 220/132/33 KV, 3 Phase ,Auto Transformer suitablefor NIFPSwith Bushing CTs and NCTS andRTCC panel alonwith BCUand other accessories as per technical specification ofAuto Transformer. 220KV & 132KV bushingshall be of RIP/RIS type. 34 Nitrogen injection type Fire Prevention and ExtinguishingSystem including reservoir tank andall required accessories for 160 MVA, 220/132/33 KV, 3 Phase Power Transformer 35 50 MVA, 132/33 KV, 3 Phase, 2 winding Power Transformerwith Bushing CTs and NCTsincluding RTCC panel alongwith BCU and alongwith all accessoriesin line with technical specification of Power Transformer.132 KVbushingshall be of RIP/RIS type. 36 6.3 MVA, 33/11 KV, 3 Phase, 2 winding Power Transformer with Bushing CTs and NCTs in line with technical specification of Power Transformer . As per Tech spec 37 STATION SERVICE TRANSFORMER: 315 KVA, 33/0.415 KV, 3Ph, 2-Windingas per technical specification andrequirement 38 EARTHINGTRANSFORMER: 33KV, 3 Ph ,fault current rating of874 Amp for 30 secas per Technical Specification and requirement 39 Isolators : As per Technical specification 40 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITHOUT EARTHING SWITCH (excluding insulators) for HV side of 160 MVA Transformers(water proof mechanism housing with auxiliary switch) 41 Solid Core Insulator for each set of above Isolators 42 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITH EARTHING SWITCH (excluding insulators) for Line bay(water proof mechanism housing with auxiliary switch) 43 Solid Core Insulator for each set of above Isolators 44 132KV, 1250 A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with Earth Switch for line feeder, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 45 Solid coreInsulator for each set of above Isolators 46 132KV, 1250A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with out Earth Switch for Transformers, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 47 Solid coreInsulator for each set of above Isolators 48 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - forHV side of 33/11KV Transformer & Earthing Transformer(excludingInsulators ) 49 Solid coreInsulator for each set of above Isolators 50 33KV, 2000 A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - for LV side of 132/33 KV Transformer,(excludingInsulators ) 51 Solid coreInsulator for each set of above Isolators 52 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assembly with Horn-gap fuse units to be mounted on same structure of isolator ( for Station service Transformers ) as per Tech. Specification(excluding insulator) 53 Solid Core Insulator for each set of above Isolators 54 LIGHTNINGARRESTORAs per Technical specification 55 198 KV, single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos. 160 MVA Transformersas per technical specification and as per requirement. (Polymer type) 56 198 KV class polymer type LA at Composite Tower 57 120 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless for 2 nos 160MVA Transformers,2 nos 50MVA Transformerand line bays (Polymer type) 58 42 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos 50MVA transformer, 3 Nos 6.3 MVA 33/11 KV Transformer &2 nos.315KVA station serviceTransformer) ((Polymer type) 59 12 KV, 3 phase 10KA,Station class GapelessLA (LV side of 3nos. 6.3MVA Transformers) (Polymer type) 60 220 V Battery & Charger( As per technical Specification ) 61 VRLA Battery SET - 800AH 220 Voltas per Tech Spec. 62 Battery Health monitoring system forabovementioned 220V batteries as per Technical Specification. 63 Battery Charger - 220Volt. suitable for above Battery set in line with Technical Specification(Float Charger capacity - 80A and Float cum Boost Charger capacity - 150A) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also. 64 VRLA BATTERY SET -75 AH 30 VoltCapacity will be as per design or75 AH whichever is higher as per uploadedtech spec 65 Battery Charger - 30Volt. Foalt cum Boost Charger Float charger capacity 35A or as per design whichever is higher as per Tech Spec ( uploaded) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also.(as per uploaded spec.) as per uploaded spec 66 PROTECTION PANEL ( SIMPLEX REAR Open Door type ) inclusive of all relays, Annunciator (Minimum 24 windows or more as per scheme requirement, with RS485 port for Modbus Communication, Auxiliary AC and DC Supply as well as Dedicated AC Fail and DC Fail windows) at each panel and other accessories as per specificaction and requirement. (Protection Panels will be installed in Relay Room.) 67 Protection panel with BCU and Breaker Control Switch for 220 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 68 Protection Panel with BCU and Breaker Control Switch for 220 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, Circulating Curent Protection Relay in addition to all other Transformer HV Protection relays are to be considered in HV side Panel). 69 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 220 KV Bus Coupler complete as per Tech. Spec. 70 220 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 71 Protection panel with BCU and Breaker Control Switch for 132 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 72 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. 73 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, HV REF Protection Relay in addition to other Transformer HV Protection relays are to be considered in HV side Panel) 74 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 132 KV Bus Coupler complete as per Tech. Spec. 75 132 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open Detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 76 Protection Panel with BCU and Breaker Control Switch for 33 KV Line Feeder as per Tech. Spec. 77 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/0.415 KV Station Service Transformer (S.S.T.) as per Tech. Spec. Panel schematics will be similar to Line Feeder Panel, along with addtitional S.S.T. Supervision Relays. 78 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 132/33 KV Transformer as per Tech. Spec. 79 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/11 KV Transformer (considering HV REF Protection Relay, HV Over-current Relay and all other accessories alongwith space and provision for future Transformer Differential Relay) as per Tech. Spec. and actual requirement. 80 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both side Bus PTs) and Breaker Control Switch for 33 KV Bus Section bay as per Tech. Spec. 81 Meter Panel without meter( As per drawing uploaded) 82 XLPE Copper Cableas per Technical Specification 83 220 KV 630 Sq. mm single Core Copper Cable AL sheath forLine from Composite Tower To GIS- Single phase connection with double run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 84 220 KV 630 Sq. mm single Core Copper Cable AL Sheath for HV side of 160 MVA TransformersSingle phase connection with single run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 85 220 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) forLine bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 86 132 KV 630 Sq. mmsingle core Cu cable AL sheath (as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 160 MVA, 220/132/33 KV Transformers - Single phase connection with doublerun cable for each phase - The actual length will be decided after finalisation of LUP drawing. 87 132 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 50MVA, 132/33 KV Transformers and Line bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 88 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer - Single phase connection with double run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 89 33 KV 240 Sq.mmThree Core copper cable for three 33/11KV 6.3MVA Transformer , two 315KVA Transformer - Three Phase Connection with single run cable - The actual length will be decided after finalisation of LUP drawing. 90 11 KV 400 Sq.mm 3 coreCopper for 33/11KV 6.3MVA Transformer - Three Phase Connection with singlerun cable - The actual length will be decided after finalisation of LUP drawing. 91 Outdoor End Termination Kit/ cable sealing end and other required accessories for above XLPE cables as per requirement and specification : 92 For 220KV 630 Sq.mmsingle core copper cable for Line 93 For 220KV 630 Sq.mmsingle core copper cable forTransformer 94 For 220KV 400 Sq.mmsingle core copper cable for Line 95 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 96 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 97 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 98 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 99 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 100 Indoor End Termination Kit for above XLPEcable : Dry Plug-In type GIS Indoor Termination kitwith all its accessories complete. This includes cable connecting contact plates and cable terminal box at GIS termination of type-A, Fig -3 as per IEC 60859 with support structure and insulator as per approved drawing, technical specification /requirement as per the following cables. For 33 : Dry Heat Shrink type as per approved drawing, technical specification /requirement as per the following cables. 101 For 220KV 630 Sq.mmsingle core copper cable for Line 102 For 220KV 630 Sq.mmsingle core copper cable forTransformer 103 For 220KV 400 Sq.mmsingle core copper cable for Line 104 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 105 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 106 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 107 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 108 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 109 Generator 110 DG set 100KVA with all accessoriesas per Technical specification 111 Communication Equipment (As per technical specification, BOQ and mentioned Annexure) 112 Fibre Optic Terminal equipment ( with minimum five redundantdirections with MSP protection)/Optical Line Terminal Equipment (SDH-STM 4) for the Sub Station Reduntant Power Supply card and Control card etc. complete to meet Tech. Spec. Requirement in all respect ( should be compatible with FO equipment at BAPL,SLDC & Backup SLDC for data and voice communication and carrier aided protection). 113 E1 Interface cards( Minimum 16 interfaces/card) 114 Ethernet Interfaces10/100 Mbps with Layer-2 switching ( Minimum 8 interfaces/card) 115 Equipment Cabinets 116 Main Distribution Frame (100 pairs) 117 Pre-connectorised optical fibre patch cords as per requirement 118 E-1 Port Interfacing Cable 119 EPAX (with cabinet)To be suitable both for FO Equipment and PLCC equipment with 2 digit, 3 digit & 4 digit Station numbering facility and programmable features such as using analog telephone & Laptop with (4 x 8 nos.) Local Subscribers 120 Digital Teleprotection Coupler suitable for integration with SDH terminal equipment to communicate on G 703 (E1, 2 Mbps) with minimum eight commands as per Technical Specification requirement. 121 Telephone Receiver (2-wire) for connection with EPAX,to be installed at different rooms of GIS cum Control& office building, C-type quarter, Colony buildings, Security room at main gate and other areas as per direction of Site-In-Charge. 122 Telephone cable (armoured) for all2-wire telephones & other requirements as per specification and as per requirement 123 STP Data Cable(CAT 6) with flexible GI conduit pipe for data transfer and for connecting IP phones (placed at Control room, communication room, Sub-Station In-charges room etc.) with FO Panel 124 Two no. licensed software for configuration of SDH and DPC to be handed over in two pendrive to Communication wing 125 48V, 300AH VRLA type Battery 126 48V, 60A Battery Charger 127 48V DCDB as per technical specification 128 Integration withexisting Fiber Optic System at connecting Sub-Stationon optical channel (STM-4), in consultation with the OEM, whose equipment is installed at other end. i) for voice & data communication ii)for carrier aided protection purpose -with supply of equipment and material(SFP,Patchcord, etc) as required. Intigration of new SDH, with existing SDH at connecting substation must not affect repoting of existing SDH at NMS, for which necessay action needs to be taken. 129 SAS system (as perindicative Scheme diagram, Technical Specification and requirement) -Monitoring & Control of the Sub Station from a far end Operting Station in addition to local unit 130 Rack mounted Main Server (Intel XeonSilver 4215processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-1, for connection FO port to be considered). 131 Rack mountedStandbyServer (Intel Xeon Silver 4215 processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-2, for connection FO port to be considered). 132 Local HMI (client Terminal) with 32 Monitor (LED) 133 Remote HMI PC with monitor (32LED) and necessary software for remote control and monitoring via local substation Gateway ,shall support IEC60870-5-104and IEC 61850 protocol. Remote HMI shall 100% replication of local substation HMI in all respect . 134 MainGateway (Intel Xeon Silver 4215 processor or higher)-Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol. 135 Standby Gateway (Intel Xeon Silver 4215 processor or higher)- Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol 136 Disturbance Recorder Cum Engineering Workstation PC (Industrial Grade) withMonitors (24 size- LED) 137 1 no PC with monitor (24 size LED) and necessary software for remote end to fetch DR data from relays and to configure all relays . 138 Rack mounted complete GPS unit, to be mounted in server panels . 139 Laser Colour Printer (suitable for at least A3 size) 140 Dot Matrix Printer 141 PRP Compliant, managed 20 FO port Ethernet Switch, industrial grade. 142 SAS application software with required license (suitable for 8000 signals, with life time validity) and other relevant operating & system software for running the scheme successfully. 143 Redundant Inverter of 5KVA or higher capacity in HOT-STANDBY Mode, on220V station battery , to feed SERVER, GATEWAY, HMI, Engineers WorkStation,Monitors, Ethernet Switches, KVM Switches,Printers, MODEM/ROUTER, etc. 144 Cabling System -Multimode / Single Mode Dual Window armoured fibre optic approach cable as required with HDPE duct, Flexible GI Conduit, all other power & control cables, Jacks, connectors and any other hardware to meet functional / performance requirement. 145 LIU having minimum 12 ports. 146 Red Box having minimum 4 RJ45 & 2 FO ports. 147 Remote Monitoring & control (wherever required) of Station Auxilliary System like Fire Fighting System, Air Conditioning System, Battery System, Lighting System, ACDB, 220V & 48V DCDB,replica of annunciator with buzzer & reset arrangement,& fire fighting annunciatoretc. complete as per technical specification requirement. For auxilliary system, AUX BCU to be mounted in separate panel. 148 Premium quality Integrated Control console deskwith chairs and other furnituresfor HMI Workstations, DR PC, telephones, storing of log sheets & manuals etc. suitable for three operators 149 Data Integration with SLDC and Back up SLDC End Including programme as per technical specification and also as per site requirement by directly communication with agency engaged for AMC of SCADA at SLDC and Back up SLDC End. 150 Router cum firewall shall be provided at local end for remote data transmission . 151 Network panel and other material / equipment / accessories required for successful completion ofthe job . 152 Automated notification in the form of SMS - i) SMS is required to be sent to 5 (five) mobile numbers at a time. ii) When required, any number can be deleted or altered. For that easy interface is to be provided. A log (with user-id and time) for the same is also required to be maintained. iii) The type of disturbaces or trippings for which SMS to be sent must be cofigurable. iv) All required hardwares and softwares to establish the system is under scope of the bidder. v) ISP connection in the name of WBSETCL and any formalities (if required) is to be done by the Bidder.SIM will be provided by WBSETCL. vi) After handing over the system, any recurring charges for SIM will be borne by WBSETCL. 153 Vendor Assessed Quantities: 154 ACDISTRIBUTION BOARD(comprising of Main ACDB, Sub-ACDBMLDB,DB) complete as per technical specificationand as per requirement. In addition to incomers from 2 nosStation Transformer, and Diesel Generator, suitable incomer for Solar Roof Top plant (40 kWp capacity) is to be considered as per requirement for GIS building and 11 KV room . 155 DCDISTRIBUTION BOARD (220 V DC)complete as per technical specificationand as per requirement 156 30V DCDB (with single source) for 11 KV System as per uploaded Tech spec 157 Control cable 1.1KV grade( Cupper ) as per TECH Spec and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing . Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 158 19 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 159 16 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 160 12 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 161 8 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 162 4 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 163 5 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification.(For all CT, PT & CVT connection. For CT individual colour coded cables are to be used for individual core). 164 4 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification. 165 5 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 166 3 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 167 2 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 168 POWERCABLE-Multi Core, PVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing (Allcablesshall be of Copper only.)Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 169 1C X 500 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 170 3.5C X 185 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 171 4C X 16 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 172 4C X 25 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 173 4C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 174 4C X 35 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 175 2C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 176 1C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 177 2C X 4 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 178 ACSR CONDUCTORwith accessoriesas per Technical Specification and as per requirement 179 ACSR Moose 180 ACSR Panther 181 Earth /Shield wirefor LM down comer 182 ALUMINIUM TUBULAR PIPE (Schedule 80) as per Technical Specification and as per requirement 183 3 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 184 2.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 185 1.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 186 CLAMPS,CONNECTORS,BUNDLE SPACER, Hardware fittings & accessoriesincluding equipment connectors(SUITABLE FOR SCH. 80) and as per approved ACSR conductor as per Technical Specification and as per requirement 187 220KV System 188 132KV System 189 33 KV System 190 11KV System 191 0.4KV System 192 Solid Core POSTINSULATOR& Anti fog type Disc insulatorwithhardware fittings and accessories as per Technical Specification andrequirement 193 220KV System 194 132KV System 195 33 KV System 196 11KV System 197 ILLUMINATION SYSTEM 198 ILLUMINATION SYSTEM COMPLETE (Both Indoor & outdoor)GIS building control building switchyard periphery C type building B type buildingPump House, Security Goomty / Barrack, DG Room,other area installation including light pole with foundation worketc as per technical specificationandrequirement. Allluminaire used shall be of LED type (irrespective of the type mention in specification) and all fans shall be of energy efficient BLDC type. 199 Dehumidifier as per specification 200 Dehumidifier with suitable capacity & size for 33 KV Switchgear Roomas per approved drawing 201 Direct Stroke Lightning Protection for GIS building(considering Roof Top Solar Plant), Control builting, FFPH, as per relevant IEC. 202 Furnitures and Gadgets for Conference Room - Premium quality furnitures of reputed brand like Godrej or equivalent are to be considered. However, before procurment of furnitures and gadgets, written approval from WBSETCL site-in-charge is to be taken. 203 Conference table suitable for 30 person 204 Executive High Back chairs 205 Digital Audio / visual projector - 4K resolution, 2 nos USB 2.0 and 2 nos HDMI 2.0 ports (Preferred make - Sony, Epson, JVC, Panasonic) 206 64 or higher Interactive smart whiteboard of reknowned make 207 Meeting room Audio system (microphones - 30 nos., wall mounted speakers, amplifiers, other required hardwares & softwares) - (Make Harman, Sennheiser or equivalent) 208 Decorative dimmable LED lights (average 500 lux level) 209 High quality window blinds matching with room interior 210 AIR CONDITIONING SYSTEM COMPLETE as per Technical Specification and as per requirement (All machines must be of same make.) 211 RelayRoom and SAS Room & communication Room- Ductable Air Conditioning System is to be considered. -All machines must be ofsame make . Considering continuous operation ,machines must be of Industrial gradeand refrigerent must be of R32 or better environmental standards .as per spec 212 5star rated Split type Non-Ductable AC for Battery & Chargerroom, In-Charge Room, Conference room DB Room etcAll machines must be ofsame make . Considering continuous operation, machines must be of Industrial grade / 5 star rated split and refrigerent must be of R32 or better environmental standards as per spec 213 FIRE FIGHTING & FIRE PROTECTION SYSTEM - As per Tech spec 214 Fire hydrant system in ring formation along the periphery of switchyard covering entire portion (Entire 132 KV Switchyard &220 KV switchyard), GIS building, Control Building etc as required. 215 Portable fire extinguisher & bucket at key locations of switchyard ,control room, GIS building, office area ,residential and other building and near each Power Transformer as per Technical spec . and as per requirement. 216 Fire Alarm System (Concealed cabling is preferred ) - i) Smoke & heat detection system covering all the rooms of GIS cum Control room building ii) adequatebeam detector with redundancyfor GIS room - as per technical specification & requirement 217 CCTV Survelliance system (as perTech specification ) - The system shall be capable to integrate with central control centre. The actual quantity shall be finalised depending on the approved design . 218 Fixed Bullet camera (short range) with all accessories -as per technical specification. 219 Fixed Bullet camera (long range) with all accessories -as per technical specification. 220 Fixed Dome camera with all accessories-as per technical specification. 221 PTZ camera with all accessories-as per technical specification. 222 IP Based Outdoor Thermal Camera with all accessories as per technical specification 223 VMS management server with 30 days recording facility for minimum 40 cameras (with MS Windows professional operating system) -as per technical specification. 224 Video surveillance software and license for 40 cameras or more (which shall be valid for lifetime) -as per technical specification. 225 40 4K Display, 24 x 7 operation; as per technical specifications 226 2 KVA online UPS with 30 minute backup-as per technical specification. 227 24 Port PoE 1G Network Switch with 4 nos SFP Ports along with 1G SM SFP Modules; as per technical specifications 228 Required number of Industrial Grade 4 Port 1G Network Switch with 2 Nos. SFP Ports along with 1G SM SFP Modules; as per technical specifications 229 Media Converter, PTZ keyboard with joystick, cabinet, junction box, POE injector, LIU, power supply, Indoor floor mount rack, outdoor rack, clamp, connector and hardware for camera fixing etc. -as per technical specification. 230 All types of armoured fibre optic cables, CAT 6 cables, armoured copper cables, HDMI cable, HDPE conduits, PVC straight pipe and accessories etc. required to complete the system-as per technical specification. 231 Computer Table, rolling Chair, additional mounting pole and Other tit-bit materials not specified above but required for successful completion of CCTV surveillance systemas per site requirement. 232 NEXT GENERATION FIREWALL/ CYBERSECURITY GATEWAY and all required hardwares & software for integration with remote Control Command & Centre AS PER TECHNICAL SPECIFICATIONS. 233 One additional viewing unitsat In-Charge Room with all required hardware and software 234 SUBSTATION EARTHING SYSTEM : As per Technical specification 235 32mm dia or higherMS rod for main earthmat grid,corner mesh and periphry for outdoor switchyard . The actual quantity shall be finalised depending on the approved design (Only design quantity with lap length without any wastage for main mat, periphry& corner mesh will be considered for payment.) The Earthmat design is to be done considering earth resistivity of 30 Ohm-m oractual measured value whichever is higher. 236 32mm dia or higherMS rod for riser below and aboveground auxiliary Mat fencing and gate earthing bending length and overlapping length as per requirement & as per approved drawing 237 GS flat for riser above ground / cable trench & other areas.Rod/pipe electrode , test link and other materials etc. - as per requirement, technical specificationand approved design/layout including earthpit. 238 Earthing for GIS enclosure and GIS building as per manufacturers recommendation including civil work. 239 Earth Link Box, SVL, Earth Strip, earth continuity cable for single bondwherever required for Earthing of allXLPE Cablecomplete at cable conductor junction point etc as per technical requirement / as per approved drawings. 240 Earth Strip and other accessories including lugs for link box etc wherever required for Earthing of allXLPE Cablecompletei as per technical requirement / as per approved drawings. 241 3 ph Earth Link Box with SVLas per technical requirement / as per approved drawings. 242 3 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 243 1 ph Earth Link Box with SVL as per technical requirement / as per approved drawings. 244 1 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 245 6.6 KV/3.8 KV Copper Bonding Cableas per technical requirement / as per approved drawings. 246 1.1KV Grade 240 sqmm CopperEarth continuity Cableas per technical requirement / as per approved drawings. 247 GRID CONNECTED ROOF TOP SOLAR POWER SYSTEM (As per Technical Specification) 248 5kWpSolar Roof Top plant (at the roof of GIS & Control building) having high quality mono. crystalline type solar PV module from reputed brand (as mentioned under WBSETCL Makers list), Mounting structures (Fixed Type) with Civil pedestals including civil work as per requirement. 249 i) High quality inverter from reputed brand as mentioned under WBSETCL Makers list) suitable for 40kWp solar roof top plant. ii ) All other required accessories- Data logger with CPU, LCD monitor, UPS,Metering,Junction box & distribution boxes, Type-II Surge protective device, string monitoring uints, pyrano.meter with sensors, all Cables, hardware, earthing & lightning protection materials, required furnitures & cabinets, conduits etc. to complete the system of 40kWp grid connected plant 250 Essential spares necessary for operation, routine maintenance and testing of equipment supplied for 3 years to be covered under Annual Maintenance Contract. 251 MISCELLANEOUS ITEMS -As per Technical specification 252 i) Glow signboard for name of the substation- minimum size 50 sq ft, ii) schematic SLD on glow signboard iii) Danger plate, phase plate, bay nameplate etc iv) Statutory caution boards made of mild steel of 250 mm x 200 mm and at least 2 mm thick and vitreous enamelled, white on both sides and with inscription in signal red colour on front side as required. v) Shock treatment chart in local and English language duly mounted on wooden frame with glass as required vi) Safety Slogans - to be put up in Offices and Sub-station premises (Site-in-charge may select the slogans from WBSETCL Safety Manual, Version 2.0, Page 18)vii) WBSETCLLOGO & Sub-Station Nameat main gate of Sub-Station entry with good quality durable materials 253 Ferrules & lugs, GI conduit, Cu flexible wires for panel earthing etc. 254 .Angle, Channel and other hardwares for installation of panels, DBs etc. 255 Supply of itemsfabrication marker, tags,Protection cover tiles, PVC warning tape, route marker, jointing marker, clamps connector etc as per specification & approved drawing 256 Trefoil clamp suitable for approved XLPE cable 257 Bay marshalling kiosk, dummypanel, junction box, , Lighting & other Distribution Boards etc. As per requirement& as per Technical specification 258 Bay marshalling kiosk, 259 Dummypanel, 260 Junction box, (CT,PT,CVT as per requirement 261 Distribution Boards as per requirement 262 Cable Tray (Ladder type & perforated type etc ) as per requirement for indoor cable trench and and as per requirement within GIS building 263 Industrial type Exhaust Fans and mechanised louvers of required quantity for 220KV & 132KV GIS Hall, 33 KV indoor switchgear& 11 KV Switchgear Room as per requirement & as per Tech Spec 264 HDPE Pipes 265 200 mm Dia 266 150 mm Dia 267 One storage type RO + UV + UF water purifier for office building 268 Spares:- Spare relays including test jack are to be delivered after duly tested at CTD WBSETCL on chargeble basis. All materias will be as per scheme of this project ) 269 Distance Protection relay (as approved at 220 KV Line bay for Main-1 potection) 270 Distance Protection relay (as approved at 220 KV Line bay for Main-2 potection) 271 Distance Protection relay (as approved at 132 KV Line bay for Main-1 potection) 272 Distance Protection relay (as approved at 132 KV Line bay for Main-2 potection) 273 Transformer differential Relay(same as approved for 220 KV Transformer bay) 274 Transformer differential Relay(same as approved for 132 KV Transformer bay) 275 BCU (same as approved for 220KV bays ) 276 BCU (same as approved for 132KV bays ) 277 BCU (same as approved for 33KV bays ) 278 BCU (same as approved for auxilliary system) 279 PRP Compliant, managed Ethernet Switch, industrial grade. (same as approved for SCADA Systeml) 280 Over Current& Earth fault Relay 281 Bus Bar Differential Relay (One Central Unit and one Peripheral Unit) 282 Trip Relay 283 VT selection Relay 284 Spares: Spare are to be delivered at nearest store in consultation with in charge All materias will be as per scheme of this project. 285 220KV GIS Circuit Breaker complete mechanism 286 220KV GIS Disconnector complete mechanism 287 220KV GIS High speed earth switch complete mechanism 288 132KV GIS Circuit Breaker complete mechanism 289 132KV GIS Disconnector complete mechanism 290 132KV GIS High speed earth switch complete mechanism 291 33KV CT - same as supplied for Line bay 292 33KV CT - same as supplied for 50 MVA Transformer bay 293 Safety Equipment 294 Full Body Safety Harness with Twin rope lanyard, length < 3 meter with waist belt and accessories as per IS - 3521 295 First aid box complete with all items (as perAnnexure in line with WBSETCL Safety Manual, Version 2.0) - to be placed at Control Room & Maintenance Room 296 Discharge cum earthing rod - Highly insulated FRP telescopic type with all accessories suitable for 245 KV system or higher,CPRI type tested as per IEC - 1230:1993 & IEC - 1235 with tested epoxy earthing rod for 10 KV /ft for 1 min as per IEC- 855 297 Safety Helmet - Made of Polyethylene/ glass fibre reinforced with head band, cradle, strap fittings with withstanding temp of 50oC as per IS – 2925 (Suitable stand / Racks are to be provided to store the helmets. Helmets are to be colour coded for visitors, technical staff and others) 298 Gum Boot made of Rubber (Suitable stand / Racks are to be provided for storage.) 299 Renowned make High Voltage Detector - Suitable for 11 KV to 245 KV , 50 HZ system with sensing level 1 mtr. for 132/220/ 400 KV system complete with HV probe, 5.0 mtr telescopic insulation stick with visual LED and Buzzer indication as per IS - 13771/ IS - 2071 300 Safety shoes - Double density PU sole, leather with hard Toe cap, Non-woven Eva lining, anti static /electric shock proof Insole (with minimum electrical resistance and high voltage of 18 KV), conforming to IS – 15298 301 Hand Gloves - Made of soft quality rubber, seamless latex, shock proof, for electrical purpose suitable upto33 KV -system as per IS - 4770 302 Electric Arc Protection Suit - FR suit compatible to wearwith hood, jacket, face shield, trouser etc complaint with NEFA- 70 E standard as per IEC - 61482-1-1-2007/9 303 Insulating mat - High density insulating matsasper IS - 15652 with ac(rms) kv 3.3, sizes of rolls 5000 mm X 1000 mm (to cover entire operating length of 33KV switchgear, DB room & Panel room) 304 Safety Ladder - Single step self supporting type with complete Fiber glass, 3 inch wide, antiskid fibre steps, non - slip fibre glass shoes with thick rubber pad, Height 8 ft 305 Safety Torch / Search Light - Body:- Fibre glass, PCB - glass epoxy to meet all weather condition, Circuitry - IC Control, Charge -220 Volt AC, Light Source - 12 V Halogen Bulb, 55 watt, Power source - 12 volt, 7 AH sealed battery, Extra jack tobe provided for direct lightning by 12 volt DC, Continuous run - 2 hr High beam Rechargeable Hand Held Search light 306 Lifting Rope - Hemp Rope / Sisal Rope / Manila Rope - One inch dia., 30mtr long 307 Passenger Elevator (6 person capacity, ) - For GIS & Control buildingcomplete in all respect as per technical specification and as per requirement. 308 Industrial grade Vacuum Cleaner of reputed make 309 Civil Part: 310 Supply, fabrication, galvanisaton of variousswitchyard & equipment structures,LM-Lattice type ( 35Mtr or 50 Mtr-based on DSLP Calculation), XLPE cable supporting structure completeas per approved electrical layoutdrawings and technical specification (Electrical & civil) and as per requirement complete. (including Nuts & Bolts and foundation bolts) 311 Switchyard Structures including Nuts & Bolts 312 Foundation Bolts for switchyard structures including nuts, washers and anchor plates (Foundation Bolts shall be galvanisedupto threaded length from top) 313 Supply, fabrication of various structures (MS FLAT, MS Plate, Insert plate, Angles, Transformer Rail, Channels, ISMB, Chequred plate, MS grating for GIS Building, Transformer, Cable trench , drain etc. as per approved drawings, technical specification (Electrical & civil) andrequirement complete.
Contract Date: May 11, 2026 Contract Value : 242.30 Crore
Government Departments No of Bidders 3
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
12.
Housing Urban and Rular Development #10825500 Price Bid
Repairing Of Fire Downcommer And Wet Riser System At Scvr Iti Dheerpur Delhi , Repairing Of Down Comer Leakage On The Various Location Of R . C . C Etc And Repairing The Leakage Point By Cutting The R . C . C Floor & Welding To Make It Leakage Free Etc . Complete As Reqd . , Supplying , Installation , Testing And Commissioning Of Electric Driven Terrace Pump Suitable For Automatic Operation And Consisting Of Following , Complete In All Respects , As Required: ( Terrace Pump ) ( A ) Horizontal Type , Multistage , Centrifugal , Split Casing Pump Of Cast Iron Body & Bronze Impeller With Stainless Steel Shaft , Mechanical Confirming To Is : 1520B ) Suitable Hp Squirrel Cage Induction Motor Tefc Type Suitable For Operation On 415 Volts , 3 Phase , 50 Hz , Ac Supply With Ip55 Class Of Protection For Enclosure , Horizontal Foot Mounted Type With Class-F Insulation , Conforming To Is-325 . ( C ) M . S . Fabricated Common Base Plate , Coupling , Coupling Guard , Foundation Bolts Etc . As Required . ( D ) Suitable Cement Concrete Foundation Duly Plastered And With Anti Vibration Pads . ( Makes:- Kirloskar , Wilo , Kds ) A ) 450 Lpm At 35 M Head , Supplying And Fixing Single Headed Hydrant Valve With Instantaneous Single Headed Stainless Steel Coupling Of 63 Mm Dia With Cast Iron Wheel Isi Marked Conforming To Is 5290 ( Type -A ) With Blank Gunmetal/Stainless Steel Cap And Chain As Required : ( Lifeguard/Safeguard/Bharat/Agni/Safedge Make ) , Supplying And Fixing 63 Mm Dia , 15 M Long Rrl Hose Pipe With 63 Mm Dia Male And Female Couplings Duly Bound With Gi Wire , Rivets Etc . Conforming To Is 636 ( Type-A ) As Required : ( Safeguard/Bharat/Agni/Safedge Make ) A ) Stainless Steel ( Grade 304 ) , Supplying And Fixing Of External Hose Cabinet Of Size 900Mm X 600Mm X 500Mm Made Of 2Mm Thick Ms Sheet With 6Mm Thick Glazed Glass Doors I/C Necessary Locking Arrangement Suitable To Accommodate External Hydrant With Butterfly Valve/ Sluice Valve , 2 Nos . 15 Mtr . Long Hose Pipe , 1 No . Branch Pipe , Mounted On Wall Or Raised Bric Platform & Duly Painted With Post Office Red Externally And White Internally With Synthetic Enamel Paint Complete In All Respect , For Hydrant , Etc As Required ( For External And On Terrace ) . ( Safeguard/Bharat/Agni/Safedge Make ) , Supplying & Fixing 63 Mm Dia Gun Metal Short Branch Pipe With 20 Mm Nominal Internal Diameter Size Nozzle Conforming To Is 903 Suitable For Instantaneous Connection To Interconnect Hose Pipe Coupling As Required : Stainless Steel ( Grade 304 ) ( Safeguard/Bharat/Agni/Safedge Make ) , Supplying And Fixing First-Aid Hose Reel With Ms Construction Spray Painted In Post Office Red , Conforming To Is 884 With Upto Date Amendments , Complete With The Following As Required As Per Cpwd Specifications Part-V-2006 . ( Safeguard/Padmini/ Agni/Safedge Make ) A ) 30M . Long 20Mm ( Nominal Internal ) Dia Water Hose Thermoplastic ( Textile Reinforced ) Type-2 As Per Is:12585 B ) 20Mm ( Nominal Internal ) Dia Gun Metal Globe Valve & Nozzle . C ) Drum And Brackets For Fixing The Equipments On Wall . D ) Connections From Riser With 25 Mm Dia Stop Valve ( Gun Metal ) & M . S . Pipe , Providing , Installation , Testing And Commissioning Of Non-Return Valve Of Following Sizes Confirming To Is: 5312 Complete With Rubber Gasket , Gi Bolts , Nuts , Washers Etc . As Required : ( Makes:- Sant/Zoloto/Advance/Lifeguard ) A ) 150Mm Dia , 100 Mm Dia , 80 Mm Dia , Supplying , Fixing , Testing And Commissioning Of Butterfly Valve Of Pn 1 . 6 Rating With Bronze/Gunmetal Seat Duly Isi Marked Complete With Nuts , Bolts , Washers , Gaskets Conforming To Is 13095 Of Following Sizes As Required : ( Makes:- Sant/Zoloto/Advance/Lifeguard ) A ) 150 Mm Dia , 100 Mm Dia , 80 Mm Dia , Providing , Laying , Testing & Commissioning Of C Class Heavy Duty Ms Pipe Conforming To Is 3589/Is 1239 Including Welding , Fittings Like Elbows , Tees , Flanges , Tapers , Nuts Bolts , Gaskets Etc . And Fixing The Pipe On The Wall/Ceiling With Suitable Clamp/Support Frame And Painting With Two Or More Coats Of Synthetic Enamel Paint Of Required Shade Complete As Required : ( Make:- Jindal Hissar , Tata , Surya Parkash ) A ) 25Mm Dia . , 50 . Mm Dia . , 80Mm Dia . , 100Mm Dia . , 150Mm Dia . , Providing Laying , Testing & Commissioning Of C Class Heavy Duty Ms Pipe Conforming To Is 1239/3589 I/C Fittings Like Elbows , Tees , Flanges , Tapers , Nuts Bolts , Gaskets Etc . In Ground Including Welding , Excavation & Providing Cement Concrete Blocks As Supports , Anticorrosive Treatment With Coaltar/Asphalt Tape As Per Is 10221 , Refilling The Trench Etc . Of Following Sizes Complete As Required . ( Make:- Jindal Hissar , Tata , Surya Parkash ) A ) 150Mm Dia , Supplying And Fixing Of Fire Brigade Connection Of Cast Iron Body With Gun Metal Male Instantaneous Inlet Couplings Complete With Cap And Chain As Reqd . For Suitable Dia Ms Pipe Connection Conforming To Is 904 As Required : ( Make :- Life Guard , M-Tech , New Age ) A ) 4 Way - 150 Mm Dia M . S . Pipe , 2 Way - 100 Mm Dia M . S . Pipe , Provision For Supplying And Fixing Of Pressure Gauge Made Of Brass Burden Tube , Movement And Socket , Pressed Steel M . S . Casing , Stove Enameled Black Finish , Accuracy +/- , Temp . Limit . 90 Degree Celsius . ( Make:-H-Guru/ Indloss / Equivalent ) , Providing & Fixing Of Pressure Switch In M . S . Pipe Line Including Connection Etc . As Required . ( Make:-H-Guru/ Indloss / Equivalent ) , Provision For Providing And Fixing Gunmetal Single Acting Air Release Valve With Screwed Inlet 25 Mm Dia . ( Make:-H-Guru/ Indloss /Lifeguard , Equivalent ) , Supplying And Fixing Orifice Plate Made Out Of 6 Mm Thick Stainless Steel ( Grade 304 ) With Orifice Of Required Size To Be Fitted Between Flange & Landing Valve Of External And Internal Hydrants To Reduce Pressure At The Outlet To The Level Of 3 . 5 Kg/Cm2 Complete As Required . , Provision For Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank , Isi : 12701 Marked , With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet , Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank . Make ( Syntex/Vectus/Ganga ) , Supplying And Fixing Air Vessel Made Of 250Mm Dia , 8Mm Thick Ms Sheet , 1200Mm , In Height With Air Release Valve On Top And Flanged Connection To Riser , Drain Arrangement With 25Mm Dia Gun Metal Wheel Valve , With Required Accessories , Pressure Guage And Painting With Synthetic Enamel Paint Of Approved Shade As Required . , Provision For Scraping The Existing Paint & Rust With The Help Of Emery Paper From The Ci/Ms Pipe Of 100 Mm Dia & Applying To Or More Coats Of Synthetic Enamel Paint Of Approved Brand & Manufacturer To Give & Even Shade Complete Etc As Reqd At Site ( Asian/ Nerolac/ Burger Make ) , Provision For Supplying Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Power Cable Of 1 . 1 Kv Grade Of Following Size On Wall Surface As Required . ( A ) 3 X 10 Sq Mm ( Makes:- Polycab , Havells , Finolex ) , Provision For Supplying & Fixing Of 7 . 5 Hp Dol Starter With 380/415 Volts . Coil Relay Range 9 To 13 Amp On The Wall I/C Connection Testing Etc . As Required ( Make : Bch/L & T ) , Credit Of Material Against Above Work I ) Fire Fighting Motor/Water Supply Assorted Size , Valves Assorted Size 65 Mm / 80Mm/100 Mm/ 150Mm , Rrl Hose Pipe Coupling , Hose Reel , Hose Cabinet Assorted Size , Fire Brigade Connection , Pressure Gauge , Cable Assorted Size Of Above Work
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
17.
Housing Urban and Rular Development #10598804 Price Bid
Upgradation Of Existing Fire Fighting Down Comer System And supply installation testing and commissioning Of Manual Operated Fire Alarm System At In Licensing Unit Building At Police Station Defence Colony , New Delhi , Sub Head-I- Upgradation Of Downcomer SystemSupplying , Installation , Testing And Commissioning Of Electric Driven Terrace Pump Suitable For Automatic Operation And Consisting Of Following , Complete In All Respects , As Required: ( Terrace Pump ) ( A ) Horizontal Type , Multistage , Centrifugal , Split Casing Pump Of Cast Iron Body & Bronze Impeller With Stainless Steel Shaft , Mechanical Confirming To Is : 1520 . ( B ) Suitable Hp Squirrel Cage Induction Motor Tefc Type Suitable For Operation On 415 Volts , 3 Phase , 50 Hz , Ac Supply With Ip55 Class Of Protection For Enclosure , Horizontal Foot Mounted Type With Class-F Insulation , Conforming To Is-325 . ( C ) M . S . Fabricated Common Base Plate , Coupling , Coupling Guard , Foundation Bolts Etc . As Required . ( D ) Suitable Cement Concrete Foundation Duly Plastered And With Anti Vibration Pads . ( E ) 450 Lpm At 35 M Head . , Providing & Fixing Of Pressure Switch In M . S . Pipe Line Including Connection Etc . As Required . , Providing Laying , Testing & Commissioning Of C Class Heavy Duty Ms Pipe Conforming To Is 1239/3589 I/C Fittings Like Elbows , Tees , Flanges , Tapers , Nuts Bolts , Gaskets Etc . In Ground Including Welding , Excavation & Providing Cement Concrete Blocks As Supports , Anticorrosive Treatment With Coaltar/Asphalt Tape As Per Is 10221 , Refilling The Trench Etc . Of Following Sizes Complete As Required . , 100 Mm Dia . , Providing , Laying , Testing & Commissioning Of C Class Heavy Duty Ms Pipe Conforming To Is 3589/Is 1239 Including Welding , Fittings Like Elbows , Tees , Flanges , Tapers , Nuts Bolts , Gaskets Etc . And Fixing The Pipe On The Wall/Ceiling With Suitable Clamp/Support Frame And Painting With Two Or More Coats Of Synthetic Enamel Paint Of Required Shade Complete As Required : , 100 Mm Dia , 25 Mm Dia , Supplying , Fixing , Testing And Commissioning Of Butterfly Valve Of Pn 1 . 6 Rating With Bronze/Gunmetal Seat Duly Isi Marked Complete With Nuts , Bolts , Washers , Gaskets Conforming To Is 13095 Of Following Sizes As Required : , 100 Mm Dia , Providing , Installation , Testing And Commissioning Of Non-Return Valve Of Following Sizes Confirming To Is: 5312 Complete With Rubber Gasket , Gi Bolts , Nuts , Washers Etc . As Required : , 100 Mm Dia , Supplying , Fixing , Testing & Commissioning Of Double Flanged Sluice Valve Of Rating Pn 1 . 6 With Non Rising Spindle , Bronze/Gun Metal Seat , Isi Marked Complete With Nuts , Bolts , Washers , Gaskets And Conforming To Is 780 Of Following Sizes As Required . , 100 Mm Dia , Providing & Fixing Of Pressure Switch In M . S . Pipe Line Including Connection Etc . As Required , Supplying And Fixing First-Aid Hose Reel With Ms Construction Spray Painted In Post Office Red , Conforming To Is 884 Complete With The Following As Required . 20 Mm Nominal Internal Dia Water Hose Thermoplastic ( Textile Reinforced ) Type -2 As Per Is: 12585 20 Mm Nominal Internal Dia Gun Metal Globe Valve & Nozzle . Drum And Brackets For Fixing The Equipmets On Wall . Connections From Riser With 25 Mm Dia Stop Gun Metal Valve & M . S . Pipe And Socket . , 30 Mtr . , Supplying And Fixing Of Fire Brigade Connection Of Cast Iron Body With Gun Metal Male Instantaneous Inlet Couplings Complete With Cap And Chain As Reqd . For Suitable Dia Ms Pipe Connection Conforming To Is 904 As Required : , 2 Way-100 Mm Dia M . S . Pipe , Supplying And Fixing 63 Mm Dia , 15 M Long Rrl Hose Pipe With 63 Mm Dia Male And Female Couplings Duly Bound With Gi Wire , Rivets Etc . Conforming To Is 636 ( Type-A ) As Required : , Stainless Steel ( Grade 304 ) , Supplying And Fixing Single Headed Internal Hydrant Valve With Instantaneous Stainless Steel Coupling Of 63 Mm Dia With Cast Iron Wheel Isi Marked Conforming To Is 5290 ( Type -A ) With Blankgunmetal/Stainless Steel Cap And Chain As Required : , Single Headed Stainless Steel , Fabrication Supply Installation Testing And Commissioning Of Hose Cabinet Of Size 750 Mmx600mmx250mm Made Of 1 . 6Mm Thick ( Double Door ) Ms Sheet With 6 Mm Thick Glass Doors Including Necessary Locking Arrangements ( 30 X 24 X 10 ) Suitable For 2 Nos . 15 Mtr . Hose And 1 No . Short Branch Pipe . Complete Etc . As Required . , Supplying & Fixing 63 Mm Dia Short Branch Pipe With 20 Mm Nominal Internal Diameter Size Nozzle Conforming To Is 903 Suitable For Instantaneous Connection To Interconnect Hose Pipe Coupling As Required : , Stainless Steel ( Grade 304 ) , Supplying And Fixing Air Vessel Made Of 250 Mm Dia , 8 Mm Thick Ms Sheet , 1200 Mm In Height With Air Release Valve On Top And Flanged Connection To Riser , Drain Arrangement With 25 Mm Dia Gun Metal Wheel Valve With Required Accessories , Pressure Gauge And Painting With Synthetic Enamel Paint Of Approved Shade As Required . , Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank , Is : 12701 Marked , With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet , Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank . , Circular Tank , Painting ( One Or More Coats ) On Rain Water , Soil , Waste And Vent Pipes And Fittings With Synthetic Enamel Paint Of Approved Brand And Manufacture And Required Colour On Old Work . , One Or More Coats On Old Work , Credit For Following Dismantle Items . , 100Mm Butterfly Valves , Hose Reel Drum , 2 Way Fire Brigade Connection , Double Door Hose Cabinet , Terrace Pump , Scrap Polyethylene 2000 Ltrs . Circular Water Tank . , Sub Head-Ii- Sitc Of Manual Fire Alarm SystemSupplying , Installation , Testing & Commissioning Of Main Control And Indicating Panel Made Out Of 16 Swg Ms Sheet To Accommodate The Following Items Duly Powder Coated In Approved Colour With Louvers For Ventilation , Locking Arrangement , Audio And Visual Indication For Fire Alarm And Public Address System , Monitoring System Including Connections , Interconnections Etc Complete As Required . 10 Zone Panel For Fire Alarm System 250 Watt Amplifier Racks Suitable For Operation On 230V Ac/24V Dc Supply Conforming To Iec-268-3 Complete With All Accessories As Required - 2 Nos . ( One To Act As Standby ) Talk Back Master Station With Led Ptt ( Press To Talk ) Push Button For Operation On 230V Ac/24 V Dc Supply Conforming To Iec-268 For Simplex Mode Of Operation/Communication Suitable For 20 Nos . Talk Back Unit -1 Set . Announcement Control Desk Suitable For Selection Of Different Zones Selectively And On All Call Switch With Visual Indication Etc . Complete As Required -1 Set . Amplifier Change Over Switch For Inter Changing Amplifier -1 No . Monitor Panel For Loudspeaker Complete With Output Selector , , On/Off Switch , Fuse , Visual Indications Etc . Complete As Required- 1 No . Gooseneck Microphone With Stand And On/Off Switch- 1 No . Main On/Off Switch , Fuse Indication Lamps , Dc And Ac Voltmeters & Ammeters , Terminal Blocks Etc . Complete As Required -1 Set . Battery Charger Trickle Cum Boost To Take Complete Load Of Fire Alarm & Pa System Complete With All Accessories Including Providing & Fixing Of 2 Nos . 12 Volt , 60 Ah Each Sealed Maintenance Free Batteries -1 Set . , Supplying , Installation , Testing & Commissioning Sector Panel Suitable For Following Zones , Complete With Visual Indications For Short Circuit Fault , Open Circuit Fault , Fire Condition And All Other Standard Facilities As Per Is:2189 With Mimic Diagram For All Area/Zone Covered , Complete With All Connections , Interconnections As Required . , 4 Zone , Supplying , Installation , Testing & Commissioning Of Smoke Detector With Built In Led And Mounting Base Complete With All Connect
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
25.
Public Administrative Department #10270473 Price Bid
Tender For Repair Work Of Night Shelters At Those Bus Stands - Dismantling sundries brick work including stacking of dismantled materials as directed by the Engineer-in-charge with in a distance of 60 metre (200 feet).Chapter-7, Item No.- 691 2 M-150Brick work in 1:4 cement & c.sand mortar in foundation and plinth including supply of all materials labour, Tools & plants etc. required for proper completion of the work. S.I305 3 12 mm thick plaster with cement and c. sand of 1:25 fineness modules in 1:4 over brick work minimum thickness not to be less than 1cm.including supply of all materals labour t&p etc.SI 584 4 Providing laying spreading and compaction stone aggregates of 22.4-53mm size to water bond macadam specification including spreading in uniform thikness hand packing rooling with 3 wheeled 8-10 tonne roller in stages to proper grade and camber approved complete.(As per analysis) 5 Concrete with 4c.m. gauge stone ballast, c. sand of 1:25 F.M. and cement, in proportion of 8:4:1 in foundation and under floors including supply of all materials labour Tools & plants etc. required for proper completion of the work.(S.I - 281) 6 Supply and fixing 6mm thick China white glazed tiles in flooring or in skirting or in dado laid with 1:3 cement and approved coarse sand mortar finised with white cement slurry, jointing and polishing complete, including supply of all materials, labour and tools and plants (SI- 628) 7 Supply and fixing 6 to 8 mm thick ivory or light shades vitrified tiles 600x600 mm size in flooring and skirting with 1:3 cement and approved coarse sand mortar finised with its cement color slurry, jointing and polishing of approved quality complete, including supply of all materials, labour and tools and plants (New item no.- 4) 8 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous china wash vbasin size 550x400 mm with a pair of 15 mm C.P. brass pillar tap 9 Providing and fixing water closet squatting pan with 100 mm sand cast iron p or s trap, 10 liter low level white PVC flashing cistern including flus pipe manualy control device (handle lever) confirming to IS: 7231, with all fitting and fixtures complete including cutting and making good the wall and floors wherever required.White glazed earthen ware W.C. Pan 580 mm Dia. 2 Urinal Seat 10 Providing and fixing 28 mm thick door shutter of solid pvc foam profile with homogenous fine cellular structure having smooth outer intigral skin having 71 mm width and 28 mm thick as vertical & horizontal styles joint are made using sovent adhesive and GI C section (39 mm x 19 mm x 0.6 mm thick) or Ms pipe ( 40 mm x 20 mm) stiffener frarhe insert and telescopic polymeric L comers. The panel shall be filled with 3 mm thick high pressure compact laminate as per manufacturers specifications and direction of the engineer-in-charge, cover moulding shall be provided for covering fixing screws and elegant look. ( for WC bathroom door shutter). Item no.- 9.124 (New item) 11 Two coat of painting with synthetic enamel paint (aisan/buger) with 1 coat of primer including supply of all materials labour and T&P etc. (Si-644) 12 C.C. (1:1.5:3) Chapter no-20 New item no-9 13 M.S. or iron work of small sizes and section such as holding down bolts, hold fast, tie rods grating etc. Same as in item 502 but in M.S. Grills/Stair case railing/gates/trusher/racks etc. Item no. 502 A 14 Add 5% For PVC pipe fitting and 500 liter pvc over head tank drainage and all pipe fitting work. 15 Add 5% For Electrification fitting work.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
26.
Public Administrative Department #10270472 Price Bid
Repair work of Ch Mansharam Baratghar in Mohalla Subhash Nagar. - (a)Sand filling in plinth and under floor including supply of necessary quantity of sand from adistance not exceeding 8 Kms. from the site of work and including watering, dressing etc. labour and T&P etc. required for proper complition of the work. saplings of girth upto 30cms. measure data height of 1M. above ground level and removal of rubbish upto a distance of 50M. outside the periphery of area cleared. includingcost of sand. S.l 255 2 Concrete with 4c.m. gauge stone ballast, c. sand of 1:25 F.M. and cement, in proportion of 8:4:1 in foundation and under floors including supply of all materials labour Tools & plants etc. required for proper completion of the work.(S.I - 281) 3 M-150Brick work in 1:4 cement & c.sand mortar in foundation and plinth including supply of all materials labour, Tools & plants etc. required for proper completion of the work. S.I305 4 12 mm thick plaster with cement and c. sand of 1:25 fineness modules in 1:4 over brick work minimum thickness not to be less than 1cm.including supply of all materals labour t&p etc.SI 584 5 Supply and fixing 6mm thick China white glazed tiles in flooring or in skirting or in dado laid with 1:3 cement and approved coarse sand mortar finised with white cement slurry, jointing and polishing complete, including supply of all materials, labour and tools and plants (SI- 628) 6 Supply and fixing 6 to 8 mm thick ivory or light shades vitrified tiles 600x600 mm size in flooring and skirting with 1:3 cement and approved coarse sand mortar finised with its cement color slurry, jointing and polishing of approved quality complete, including supply of all materials, labour and tools and plants (New item no.- 4) 7 Providing laying spreading and compaction stone aggregates of 22.4-53mm size to water bond macadam specification including spreading in uniform thikness hand packing rooling with 3 wheeled 8-10 tonne roller in stages to proper grade and camber approved complete.(As per analysis) 8 Providing and fixing water closet squatting pan with 100 mm sand cast iron p or s trap, 10 liter low level white PVC flashing cistern including flus pipe manualy control device (handle lever) confirming to IS: 7231, with all fitting and fixtures complete including cutting and making good the wall and floors wherever required.White glazed earthen ware W.C. Pan 580 mm Dia. 2 Urinal Seat 9 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous china wash vbasin size 550x400 mm with a pair of 15 mm C.P. brass pillar tap 10 Providing and fixing pvc 6kg per cm sq soil or vent pipe ISI mark including digging filling trenchers and supply of clamps including supply of material labour T&P etc.100mm OD pipe 11 Providing and fixing 28 mm thick door shutter of solid pvc foam profile with homogenous fine cellular structure having smooth outer intigral skin having 71 mm width and 28 mm thick as vertical & horizontal styles joint are made using sovent adhesive and GI C section (39 mm x 19 mm x 0.6 mm thick) or Ms pipe ( 40 mm x 20 mm) stiffener frarhe insert and telescopic polymeric L comers. The panel shall be filled with 3 mm thick high pressure compact laminate as per manufacturers specifications and direction of the engineer-in-charge, cover moulding shall be provided for covering fixing screws and elegant look. ( for WC bathroom door shutter). Item no.- 9.124 (New item) 12 Two coat of painting with synthetic enamel paint (aisan/buger) with 1 coat of primer including supply of all materials labour and T&P etc. (Si-644) 13 C.C. (1:1.5:3) Chapter no-20 New item no-9 14 M.S. or iron work of small sizes and section such as holding down bolts, hold fast, tie rods grating etc. Same as in item 502 but in M.S. Grills/Stair case railing/gates/trusher/racks etc. Item no. 502 A 15 Add 5% For PVC pipe fitting and 500 liter pvc over head tank drainage and all pipe fitting work. 16 Add 5% For Electrification fitting work.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
27.
Housing Urban and Rular Development #10265028 AOC
Tender For Provision Of Lighting Arrangements And Lightening Arrester To The Records Tower Building, Chepauk, Chennai-05.; 1 Supply and fixing of UNECO surface light 15W with black/white powder coated aluminium housing and pressure die-cast heat sink having high efficiency on wall or ceilng with PVC unsheathed copper leads terminals to the fitting with tube.Make:Havells (ModelNo.UNECOSURFDLS15WLED 840S24BLK) /Equalent. 2 Supply and fixing of UNECO surface light 30W with black/white powder coated aluminium housing and pressure die-cast heat sink having high efficiency on wall or ceilng with PVC unsheathed copper leads terminals to the fitting with tube. Make : Havells (Model No. UNECOSURFDLS30WLED 840S36BLK-G2)/Equalent. 3 Supply and fixing of20WLycus Spike LED fitting on ceiling or wall necessary special fabricated clamp with PVC unsheathed copper leads from terminal to the fitting with necessary connection. Make : Havells (Model No LYCUSSPS9WLED730PSYMBOTG /Equalent. 4 Supply and Fixing of 10W Hexa Bulk HeadLED Fitting on wall or ceiling wtihPVC unsheathed copper leads form terminals to the fitting. Make : Havells(Model No. HEXAFT10WLED857SSY MBOPC/Equalent. 5 Supply and Fixing of 50W Jeta Quanto Mono Colour Flood light Fitting on terracewith Special Fitting arrangements.Make : Havells (Model No.JETAQUANTOPLUSFLS50 WLED730P30DPC ) /Equialent. 6 Supply and Fixing of 250W Jeta Leganza Mono Colour Flood light Fitting on terracewith Special Fitting arrangements.Make : Havells (Model No.JETALEGANZAFLS250WL ED730P30DTOTG )/Equalent. 7 Supply and fixing of Special type Street light Pole of 5 metre length with Foundation Bold nuts with necessary welding and concreting with construction of masonary pedestal with suitable door arrangementto house 6A SP MCB switch 4 nos, 2/4 way Female type connector on suitablehylem sheetwith 250W LED flood light fittingwith PVC unsheathed copper leads from MCB to fitting.Make : Havells (Model No.JETALEGANZAFLS250WL ED730P30DTOTG )/ Equalent 8 Supply and fixing of 1 no.6/16A two modulesocket , 1 no.16A one module switch on suitable module surface mounting Box ( Plastic ) with module cover plate (plastic) on wall with connections. Higher End 9 Supply and fixing of 32A DP MCB in suitable sheet steel enclosure with earth connection Higher End 10 Supply and fixing of 12way single pole and neutral MCBsheet steel enclosure distribution board with 1No 32A DPMCB as incoming and 10Nos 6Amps to 32AmpsSPMCB outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB’s should be with ISI mark.Higher End 11 Supply and fixing of 6 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB switch as incoming and 9 nos. 6A to 32A DP MCB as outgoing on suitable angle iron frame on wall with earth connection only Higher End 12 Supply and fixing of 6 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 100A 4P MCCB switch as incoming and 3 nos 63A TP MCB and 9 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End 13 Supply and run of 2 of 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade insuitable PVC rigid pipe on wall and ceiling with continuous earth wire connection 1.5 sq.mm copper wire with painting of suitable colour 14 Supply and Run of 2 of 2.5 sq.mm.PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigidpipe on wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire with painting of suitable colour 15 Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade insuitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire with painting of suitable colour 16 Supply and run of 2 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade insuitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 6 sq.mm copper wire with painting of suitable colour 17 Supply and Run of 4 of 10 sq.mm.PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigd pipe on wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire with painting of suitable colour. 18 Supply and Laying of 3 1/2x 50 sq.mm. PVC armoured LTUG cablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good 19 Supply and fixing of brass cable gland for 3 1/2 x 50 sqmm PVC armoured LTUG cable with earth connection. 20 Supply and providing cable end termination of 3 1/2 x 50 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete. 21 Supply and fixing of UPVC cable management box of size 100mmx 50mm with necessary connection etc., 22 Earthing as per ISI specification with an earth electrode of 2.1 Mt. class ’B’ GI pipe of dia not less than 40mm, with copper earth plate of size 125mm X 50mm X 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry 23 Supply and run of 2 of No 8 SWG copper wirein suitable PVC rigid pipe on wall / Floor/ Ground for earth connection. 24 Supply & installation of Air termination spike arrestor rod 10 mm ( Lightning rod)3 Mtrs length 25 Supply & installation of Aluminium alloy Solid Round Conductor with 8mm dia ofmaterial Al Mg Si as per IEC 62561-2 with Conductor Holder, glue, connectors, joints etc. cable run on the external wall from terrace to the ground floor with PVC pipe and clamps 26 Supply and Installation of copper 18 mm Copper Bonded Rod size of 2 Mtrs length buried in earth including OCHRE Boring of earth to the depth of 8 feet and closing the pit after filling with Bentonite Chemical 25 Kgs. 27 Supply & installation ofSS joint Test Link Box for each down comer in order to disconnect the earth termination system to enable measurement of resistance. 28 Providing scaffolding arrangements to the building for fixing of down conductors from the lighting arrestor spikes.
Contract Date: Nov 05, 2025 Contract Value : 27.39 Lakh
Government Departments No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
35.
Educational and Research Institute #9836704 Technical Bid
Tender For Various Type Of Maintenance Work- 1 Type-I Residence 2 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 3 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. 4 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: Of area 3 sq. metres and below 5 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.. In cement mortar 6 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 7 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). 8 TMT Fe-500 iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 9 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement: 6 coarse sand. F.M.-2.25 1:6 (1 cement: 6 coarse sand) 10 15 mm cement plaster in single coat on rough side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement: 6 coarse sand. F.M.-2.251:6 (1 cement: 6 coarse sand) 11 Celling6 mm cement plaster 1:3 (1 cement: 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. 12 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 13 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate 14 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @2.20kg/10 sqm. 15 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm 16 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 17 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. 18 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 19 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture 20 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture 21 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with : 4.0 mm thick glass panes. 22 Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With second class teak wood beading 62X19 mm 23 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces 24 Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. 25 Brick CobaProviding and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 26 Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick 27 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 28 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of ‘H’ section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. ‘U’ cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer’s specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter). 29 Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. 30 Fitting and other work 31 Type-II Residence 32 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 33 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. 34 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: Of area 3 sq. metres and below 35 Demolishing brick work, mud phasjka in terracing manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar 36 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 37 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). 38 TMT Fe-500 iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 39 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement: 6 coarse sand. F.M.-2.25 1:6 (1 cement: 6 coarse sand) 40 15 mm cement plaster in single coat on rough side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement: 6 coarse sand. F.M.-2.251:6 (1 cement: 6 coarse sand) 41 Celling6 mm cement plaster 1:3 (1 cement: 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. 42 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 43 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate 44 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @2.20kg/10 sqm. 45 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm 46 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 47 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. 48 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 49 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 50 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture 51 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture 52 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with : 5.5 mm thick glass panes. 53 Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With second class teak wood beading 62X19 mm 54 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces 55 Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. 56 Brick CobaProviding and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 57 Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick 58 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 59 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of ‘H’ section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. ‘U’ cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer’s specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter). 60 Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. 61 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make in all colours & shade in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 62 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red Area of slab over 0.50 sqm 63 Fitting and other work 64 Type-III Residence 65 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 66 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. 67 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: Of area 3 sq. metres and below 68 Demolishing brick work, mud phasjka in terracing manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-chargeIn cement mortar 69 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 70 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). 71 TMT Fe-500 iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 72 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement: 6 coarse sand. F.M.-2.25 1:6 (1 cement: 6 coarse sand) 73 15 mm cement plaster in single coat on rough side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement: 6 coarse sand. F.M.-2.251:6 (1 cement: 6 coarse sand) 74 Celling6 mm cement plaster 1:3 (1 cement: 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. 75 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 76 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate 77 Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @2.20kg/10 sqm. 78 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm 79 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 80 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. 81 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 82 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 83 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture 84 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture 85 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with : 5.5 mm thick glass panes. 86 Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With second class teak wood beading 62X19 mm 87 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces 88 Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. 89 Brick CobaProviding and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 90 Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick 91 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 92 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of ‘H’ section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. ‘U’ cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer’s specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter). 93 Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. 94 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make in all colours & shade in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 95 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red Area of slab over 0.50 sqm 96 Fitting and other work 97 Type-IV Residence 98 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 99 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. 100 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: Of area 3 sq. metres and below 101 Demolishing brick work, mud phasjka in terracing manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.. In cement mortar 102 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 103 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). 104 TMT Fe-500 iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 105 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement: 6 coarse sand. F.M.-2.25 1:6 (1 cement: 6 coarse sand) 106 15 mm cement plaster in single coat on rough side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement: 6 coarse sand. F.M.-2.251:6 (1 cement: 6 coarse sand) 107 Celling6 mm cement plaster 1:3 (1 cement: 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. 108 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 109 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate 110 Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @2.20kg/10 sqm. 111 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm 112 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 113 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. 114 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 115 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 116 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture 117 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture 118 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with :5.5 mm thick glass panes. 119 Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With second class teak wood beading 62X19 mm 120 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces 121 Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. 122 Brick CobaProviding and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 123 Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick 124 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 125 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of ‘H’ section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. ‘U’ cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer’s specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter). 126 Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. 127 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make in all colours & shade in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 128 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red Area of slab over 0.50 sqm 129 Fitting and other work 130 Electrification Work 131 Power Wiring 132 Cost of Sanitary 133 Coast of Plumbing work 134 Contigency 135 Renovation Work of Hostels & Academic Building 136 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 137 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. 138 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below 139 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: Of area beyond 3 sq. metres 140 Demolishing brick work, mud phasjka in terracing manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.. In cement mortar 141 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 142 RCCReinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). 143 TMT Fe-500 iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 144 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement: 6 coarse sand. F.M.-2.25 1:6 (1 cement: 6 coarse sand) 145 15 mm cement plaster in single coat on rough side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement: 6 coarse sand. F.M.-2.251:6 (1 cement: 6 coarse sand) 146 Celling6 mm cement plaster 1:3 (1 cement: 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. 147 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 148 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate 149 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @2.20kg/10 sqm. 150 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm 151 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 152 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. 153 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 154 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 155 Finishing with enamal Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture 156 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture 157 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with : 5.5 mm thick glass panes. 158 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces 159 Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. 160 Brick CobaProviding and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 161 Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick 162 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 163 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of ‘H’ section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. ‘U’ cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer’s specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter). 164 Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. 165 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make in all colours & shade in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 166 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red Area of slab over 0.50 sqm 167 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete 168 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15 x 3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. 169 PCC1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 170 Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. 171 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 172 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) 173 Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. Door chowkhats . 174 Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. Window chowkhats . 175 Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. Ventilator chowkhats . 176 Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge.The joints shall be of extruded aluminum base members, self aligning /centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). Wall Joint of 100 mm gap 177 Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates an universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.) Roof Joint of 100 mm gap 178 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 179 For Sewer LineProviding and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 100 mm diameter S.W. pipe 180 For Sewer LineProviding and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 150 mm diameter S.W. pipe 181 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 182 Providing and fixing tiled false ceiling 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit or directed by Engineer-In-Charge 183 For Sewer LineProviding and laying Non Pressure NP-4 class (Heavy duty) R.C.C. pipes (hume Pipe) including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 450 mm dia RCC pipes. (I.D. 300 mm) 184 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspectionof work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment shall be made once irrespective of duration of scaffolding.Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. 185 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank, including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba, all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 186 Supply & Fabrication of Shed with structure & profile sheet 0.5mm with 10 to 15 feet hight as given below specification of structure with enamale painting as direced by Engineer-In-Charge Columm squre Pipe 150 x 150 x 6mm Truss Vertical Sq. Pipe 50 x 50 x 4mmTruss Taper Sq. Pipe 40 x 40 x 3mm Parling Pipe 75 x 40 x 3mm 187 S/F of aluminium partition with ACP Sheet/Glass & Section 48 x 45 x 1.5 (+- 0.3), bottom 110 x 45 x 1.8 (+- 0.3) with complete all required fittings as directed by Engineer-In-Charge 188 Fitting and other work 189 Electrification Work 190 Power Wiring 191 Cost of Sanitary 192 Coast of Plumbing work 193 Contingencies 194 Interloking 195 Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturers specifications & direction of Engineer in-Charge. 80mm thick Cement concrete paver block of M-30 grade with approved colour, design & pattern. 196 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-III(size range 26.5 mm to 0.075 mm) having CBR Value-20 197 RENOVATION & MEZZANINE FLOOR OF ROOM 198 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1 cement : 4 fine sand) 199 Fixing in With cement mortar 1:4 (1cement: 4 coarse sand) chowkhats in existing opening including embedding chowkhats floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. Door chowkhats 200 Fixing in With cement mortar 1:4 (1cement: 4 coarse sand) chowkhats in existing opening including embedding chowkhats floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. Window chowkhats 201 Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface including disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge. For door/ window/ clerestory window 202 Providing and fixing 16 mm M.S. Fan clamps of standard shape and size existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 203 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. 204 Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer- in-charge. 205 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in Lab partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade 206 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 2.6.1 All kinds of soil 207 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 208 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 20 mm nominal size derived from natural sources) 209 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 210 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).bands 211 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). slab 212 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).beams 213 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) 214 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 215 Brick work with common burnt clay (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) 216 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 217 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 40x40x5 mm, joints mitred and welded by angle iron 40x40x5 mm or 40x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. chaukhats and windows. 218 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 40x40x5 mm, joints mitred and welded by angle iron 40x40x5 mm or 40x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-chargeProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding railing. 219 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with 1SI marked M.S. pressed butt hinges bright finished of required size with necessary screws.Second class teak wood 30 mm thick 220 Providing wood work in frames of doors,windows,clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).Sal wood 221 Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 30 mm thick shutters Kiln seasoned selected class of sheesham wood (Window Shutter) 222 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part 1) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (b) Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). 223 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete 224 Fixing of steel or wooden chaukhatsin position.(a) Door chaukhats 225 Fixing of steel or wooden chaukhatsin position.(b) Window chaukhats 226 12 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand) 227 12mm thick plaster in 1:3 on ceiling and soffits of stairs upto floor two level. Making drip course deep in plaster of the walls or in ceiling vertically or horizontally as required. 228 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 229 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead 230 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm 231 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. 232 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 233 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work 234 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture 235 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour with putty base 236 Providing and applying plaster of paris putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete. 237 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes 238 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels 239 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates efc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainlesssteel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 240 Centering and shuttering including strutting, propping etc. and removal of form work for :Suspended floors, roofs, landings, balconies and access platform 241 Centering and shuttering including strutting, propping etc. and removal of form work for :Lintels, beams, plinth beams, girders, bressumers and cantilevers 242 Centering and shuttering including strutting, propping etc. and removal of form work for :Foundations, footings, bases of columns, etc. for mass concrete 243 Centering and shuttering including strutting, propping etc. and removal of form work for :Columns, Pillars, Piers, Abutments, Posts and Struts 244 Electrification 245 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cablein surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 246 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.Power plug wiring in PVC conduit (4x4 sq.mm.) 247 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 248 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 249 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire 250 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch 251 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 A switch 252 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet 253 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 254 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 255 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door 256 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 257 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 75mm X 75 mm X 60mm Deep 258 Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mm X 75 mm) 259 Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes. 260 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 261 Supplying and fixing of following rating 240/415 V, 10 Kg. c curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection, testing and commissing etc. required. 63 Amp Four Pole 262 Supply & laying of aluminium conducter, PVC insulated amoured, served, sheeted cable 1100 volts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamp etc. of suitable size as per direction of Engineer-in-charge. complete in all respect the armouring of the cable shall be properly connected with the earth conductor by clamp etc. 70.0 sq Mm*3.50 core. 263 Supply and Fixing of 36 Watt to 46 Watt above 3300 leumin indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing withextended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. Cat AAA 264 Supply and fixing of 20 Watt LED Metal body batten fitting suitable for both surface & suspended with 3 year warrantee , complete in all respect . 100 lm/W , PF>0.95 , THD<10%, at full load , CRI>80 with 3 year warranty. 265 Supply and burring of Safe Earthing Electrode T-19 ( Hot Dip Galvanised) , Length up to 3000 mm , Outer GI pipe of 16 SWG and inner with crystalline conductive misture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivty with good mixture of retaining capacity and one earthing lead of 25mm x 3 mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D. & C.P.R.I. Certified. 266 S/F of 9 watt LED Bulb ISI complete. 267 Supply of Exhaust fac (Not fresh air fan) 300 mm sweep, double ball bearing complete in all respect. Usha/Crompton / Khaitan / Bajaj / Havells make. (Estimating Purpose Only) 268 Supply & erection of ceilling fan 1200mm Sweep, 230/250 Volts, 50 Hz ceilling fan with standard down rod, blades including connection etc. complete as required-. 269 ALUMINIUM 270 ALUMINIUM PARTITION 3.145 X 4.175 M (ANALYSIS) 271 ALUMINIUM PARTITION 3.145 X 4.175 M (ANALYSIS) 272 GLASS DOOR 273 Congigencies 274 Renovation of Labs 275 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead 276 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete 277 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm 278 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead area 3 sq. metres and below 279 PCCProviding and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) 280 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. Providing & fixing of hold fast for chaukhats of doors and windows.HOLD FAST 281 Providing or and of fixing anodised aluminium grill (anodised transparent dyed to required shade according to 1S: 1868with minimum anodic coating grill to grade AC 15) of approved design/pattern, withapproved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). 282 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 10.5.1 Using M.S. angels 40x40x6 mm for diagonal braces 283 Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all comers, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirementsand conforming to 1S: 3548 & IS: 16231 shall be paid separately. Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. 284 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes 285 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 40x40x5 mm, joints mitred and welded by angle iron 40x40x5 mm or 40x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. 286 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) (300x16mm) 287 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (250x10mm) 288 Providing and fixing ISI marked oxidised M.S. handles conforming to 1S:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) 125mm) 289 6 mm cement plaster of mix 1:3 (1 cement : 3 fine sand) 290 15 mm cement plaster on rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand) 291 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 292 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 293 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick DSR 11.26.1 294 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an evenshade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 295 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer 296 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. D.S.R. 13.80 297 Providing and fixing GI Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing ‘C’ wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of GI steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring ‘T’ with : D.S.R. 12.54.2 298 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar 299 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. 300 Demolishing mud phaska in terracing and disposal of material within 50 metres lead. 301 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 302 Thermo-Mechanically Treated bars work such as in reinforced concreted or reinforced brick work (when not included in overall rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage. 303 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in super structure above plinth level up to floor v level in all shapes and size in:1:4 (1 cement : 4 sand) 304 Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform 305 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. 306 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cablein surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 307 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.Power plug wiring in PVC conduit (4x4 sq.mm.) 308 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 309 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 310 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire 311 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch 312 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 A switch 313 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet 314 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 315 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 316 Supply and fixing of 16 gauge MS durm with louvers duly painted including making hole in the wall for exhaust fan and finishing property complete in all respects. 317 Supply and Fixing of 36 Watt to 46 Watt above 3300 leumin indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing withextended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. Cat AAA 318 Supply and fixing of 20 Watt LED Metal body batten fitting suitable for both surface & suspended with 3 year warrantee , complete in all respect . 100 lm/W , PF>0.95 , THD<10%, at full load , CRI>80 with 3 year warranty. 319 Supply and burring of Safe Earthing Electrode T-19 ( Hot Dip Galvanised) , Length up to 3000 mm , Outer GI pipe of 16 SWG and inner with crystalline conductive misture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivty with good mixture of retaining capacity and one earthing lead of 25mm x 3 mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D. & C.P.R.I. Certified. 320 S/F of 12 watt LED Bulb ISI complete. 321 Supply & fixing wall mounted industrial fan 450 mm sweep, double ball bearing complete in all respect. Usha/Crompton / Khaitan / Bajaj / Havells make. 322 Supply of Exhaust fac (Not fresh air fan) 300 mm sweep, double ball bearing complete in all respect. Usha/Crompton / Khaitan / Bajaj / Havells make. (Estimating Purpose Only) 323 Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flatback wash basin size 550x400 mm with single 15 mm PTMT pillar cock. 324 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm 325 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 32 mm dia 326 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm dia 327 Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 328 Providing and fixing PTMT Bottle Trap for Wash basin and sink Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms 329 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 330 Providing and fixing unplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore 331 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 a) 15 mm nominal bore 332 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. a) 15 mm nominal bore 333 Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore 334 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931: 15mm nominal bore 335 Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size) around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) 100 /90 mm dia 336 Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm 337 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.20mm dia nominal outer dia pipes 338 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.25mm dia nominal outer dia pipes 339 Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good walls etc. Internal work-Exposed on wall25mm dia nominal bore 340 Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good walls etc. Internal work-Exposed on wall40mm dia nominal bore 341 Providing and fixing GI Union in GI pipes including cutting and threading the pipe and making long screws etc. complete (new work).25mm dia nominal bore 342 Providing and fixing GI Union in GI pipes including cutting and threading the pipe and making long screws etc. complete (new work).40mm dia nominal bore 343 Providing and fixing gun metal gate valve with wheel of approved quality.25mm dia nominal bore 344 Providing and fixing gun metal gate valve with wheel of approved quality.40mm dia nominal bore 345 Repair work of Hydraulic Lab 346 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead 347 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete 348 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm 349 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead area 3 sq. metres and below 350 PCCProviding and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) 351 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. Providing & fixing of hold fast for chaukhats of doors and windows. 352 Providing or and of fixing anodised aluminium grill (anodised transparent dyed to required shade according to 1S: 1868with minimum anodic coating grill to grade AC 15) of approved design/pattern, withapproved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). 353 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 10.5.1 Using M.S. angels 40x40x6 mm for diagonal braces 354 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete 355 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) (Z-Section) 356 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes 357 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 40x40x5 mm, joints mitred and welded by angle iron 40x40x5 mm or 40x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. 358 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) (300x16mm) 359 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (250x10mm) 360 Providing and fixing ISI marked oxidised M.S. handles conforming to 1S:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) 125mm) 361 6 mm cement plaster of mix 1:3 (1 cement : 3 fine sand) 362 15 mm cement plaster on rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand) 363 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 364 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 365 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick DSR 11.26.1 366 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an evenshade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 367 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer 368 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. D.S.R. 13.80 369 Providing and fixing GI Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing ‘C’ wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of GI steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring ‘T’ with : D.S.R. 12.54.2 370 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar 371 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. 372 Demolishing mud phaska in terracing and disposal of material within 50 metres lead. 373 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 374 Thermo-Mechanically Treated bars work such as in reinforced concreted or reinforced brick work (when not included in overall rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage. 375 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in super structure above plinth level up to floor v level in all shapes and size in:1:4 (1 cement : 4 sand) 376 Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform 377 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. 378 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cablein surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 379 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.Power plug wiring in PVC conduit (4x4 sq.mm.) 380 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 381 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 382 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire 383 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch 384 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 A switch 385 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet 386 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 387 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 388 Supply and fixing of 16 gauge MS durm with louvers duly painted including making hole in the wall for exhaust fan and finishing property complete in all respects. 389 Supply and Fixing of 36 Watt to 46 Watt above 3300 leumin indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing withextended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. Cat AAA 390 Supply and fixing of 20 Watt LED Metal body batten fitting suitable for both surface & suspended with 3 year warrantee , complete in all respect . 100 lm/W , PF>0.95 , THD<10%, at full load , CRI>80 with 3 year warranty. 391 Supply and burring of Safe Earthing Electrode T-19 ( Hot Dip Galvanised) , Length up to 3000 mm , Outer GI pipe of 16 SWG and inner with crystalline conductive misture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivty with good mixture of retaining capacity and one earthing lead of 25mm x 3 mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D. & C.P.R.I. Certified. 392 S/F of 12 watt LED Bulb ISI complete. 393 Supply & fixing wall mounted industrial fan 450 mm sweep, double ball bearing complete in all respect. Usha/Crompton / Khaitan / Bajaj / Havells make. 394 Supply of Exhaust fan (Not fresh air fan) 300 mm sweep, double ball bearing complete in all respect. Usha/Crompton / Khaitan / Bajaj / Havells make. 395 Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flatback wash basin size 550x400 mm with single 15 mm PTMT pillar cock. 396 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm 397 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 32 mm dia 398 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm dia 399 Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 400 Providing and fixing PTMT Bottle Trap for Wash basin and sink Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms 401 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 402 Providing and fixing unplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore 403 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 a) 15 mm nominal bore 404 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. a) 15 mm nominal bore 405 Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore 406 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931: 15mm nominal bore 407 Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size) around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) 100 /90 mm dia 408 Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm 409 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.20mm dia nominal outer dia pipes 410 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.25mm dia nominal outer dia pipes 411 Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good walls etc. Internal work-Exposed on wall25mm dia nominal bore 412 Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good walls etc. Internal work-Exposed on wall40mm dia nominal bore 413 Providing and fixing GI Union in GI pipes including cutting and threading the pipe and making long screws etc. complete (new work).25mm dia nominal bore 414 Providing and fixing GI Union in GI pipes including cutting and threading the pipe and making long screws etc. complete (new work).40mm dia nominal bore 415 Providing and fixing gun metal gate valve with wheel of approved quality.25mm dia nominal bore 416 Providing and fixing gun metal gate valve with wheel of approved quality.40mm dia nominal bore 417 CONTINGENCIES. Please Enable Macros to View BoQ information
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Himachal Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Himachal Pradesh View Result →
39.
Defence #9663826 AOC
Term Contract For Artificer Works At Sangli Apartments, Echs Polyclinic Lodhi Road And Ahq Camp Lodhi Road In The Aor Of Age B/R Kashmir House Under Ge New Delhi; Earth Work Concrete Works Brick Work Stone Work Wood Work(Carpenters Work) Joinery Builders Hardware Steel, aluminium and Iron Work Roof Covering Ceiling and lining Floor Finishes and Pavings Plastering and Pointing White washing, colour washing and distempering Glazing Painting Water Supply (Internal W/S Only), plumbing. Electrical work (internal Electrification only) Demolition and dismantling Old brick bats retrived from demolition/dismantling Old chowkat with shutters and fittings n exc 1.5 som each retrived taking down Old chowkat with shutters and fittings exc 1.5 sqm each retrived from taking down Old aluminum glazed windows with shutters with fittings retrived from taking down. Old toughened glass door any thickness with fittings retrived from taking down. Old window glass with suncoritol film any thickness with fittings retrived from taking down.. Old SS locking arrangements/ SS hinges for glass doors Old SS handle of glass doors any size Old aluminum grill of any description, thickness Old mild steel sliding door bolt any size Old alum handle any size.. Old alum tower bolt any size Old wire cloth retrived from door/window/ventilator musquito proofing Old Gl tubing 15 mm bore Old Gl tubing 20 mm bore Old Gl tubing 25 mm bore Old bib cock of any description 15 mm bore Old stop or angle valve of any description 15 mm bore Old stop cock of any description 20 mm bore Old oval access door of any description retrived C pies any dia Old pillar cock of any description 15 mm bore Old brass ball valve / cock of any description 20 mm bore Old brass ball valve / cock of any description 15 mm bore Old PVC connection any length 15mm bore Old shower rose any dia Old PVC waste pipe 32/40mm any length Old waste fitting/coupling any size Old Aluminum beading of door/window etc Old grating of any description/size Old looking mirror any size/ shape Old PVC handle of flushing cistem retrived Flushing cistern Old flushing cistern low level Old PVC rain water pipe incl fittings of any description/dia Old gate valve 20 mm bore dia of any description Old gate valve 25 mm bore dia of any description Old towel rail of any description/length Old man hole cover of any description size Old HDPE water tank of 500 les cap Old HDPE water tank of exc. 500 litrs but nexc 1000 ltrs cap Old urinal spreader of any description Old stone slabs of any description (thickness/size Old Health faucet with PVC pipe Old drapery rod of any description Old comer glass shelf any description Old false ceiling of any description Old posts or struts of any description Old Jet spray of health faucet, pog set Old mild steel scrap Old PVC water tank covers any siz Old steel sheets of any description/thickness Old window MS handles scrap Old hydraulic door floor spring any size Old small PVC fittings/Gl fittings any bore dia not covered under above items Old PVC wall panelling scrap Old CP wall mixer scrap Old double action hydraulic door spring Old door stopperipeg set etc small itemis Old SS sink scrap Old aluminum glazed door with fittings Old alum glazed and wire gauzed windows with fittings retrived from taking down. Old aluminum glazing Old aluminum partition Old small Gl fittings 16mm dia Old Gl chain link fencing Old Gt barbed wire Old Scrap wood Old Gl tubing 40 mm bore Old Cl pipe 100/75mm bore Old AC corrugated sheets any size Old brick tiles retrieved from roof Old brass bottle trap Old toilet paper holder Old towel ring any size Old EWC Old wall mixer and over head shower Old health faucet with PVC pipe Old iron scrap any other description (by actual weight) Old wood scrap any other description (by actual weighti Old aluminium scrap any other description thy actual weight) Old brass scrap any other description (by actual weight) Old PVC scrap any other description (by actual weight) Old Unsy Paver Block any thickness Old unsv shutter not exc 1sqm any type Old unsv exc 1 sqm not exc 2 sqm any type
Contract Date: Feb 24, 2026 Contract Value : 8.62 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 8
40.
Defence #9578599 AOC
Tender For Term Contract For Artificer Works At Pts(Vikas) Sarsawa Under Ge (Af) Sarsawa - S&F in repair Single Lever Wash Basin Mixer S&F in repair comer glass shelf with CP railing S&F in repair ractangular glass shelf with CP railing S&F in repair Toilet Roll Holder S&F in repair CP Towel Ring Round S&F in repair soap dish S&F in repair over head shower size(125mmx125mm) with arm Make - Cera/Parryware/Jaquar S&F in repair Towel Rack 600mm long with Lower Hangers S&F in repair Glass Shelf size 300mm, S&F in repair CP Hand Shower with 1.0 M Long PVC connection S&F in repair one piece coloured EWC concealed P or S trap with seat cover CAMPBELL S&F in repair coloured wash hand basin with builtup counter CAESER S&F in repair 4mm thick ceiling boards S&F in repair stainless steel Plate rack of size 900x 750 x230mm &F in repairs powder coated stainless steel drapery rod of 25 mm inner dia (in lengths as directed) of approved colour with & including decorative bowel at both ends and pair of powder coated stainless steel brackets S&F in repairs PVC waste pipe for kitchen sink and wash hand basin. S&F in repairs wall mixer chromium plated (3 in 1) with arrangement for both telephonic shower and overhead shower S&F in repairs Mirror cabinet PVC frame of size 400 x 500 mm S&F in repairs 15mm brass chromium plated health faucet for EWC with including PVC Connection 1m long suitable for 15mm bore with all connected fittings, S&F in repairs Jet spray chromium plated brass for EWC with & including PVC connection 900 mm long M&L False ceiling with ArmGyp-FB ceiling tiles of 595 x595 (as approved by GE) fixed with and including galvanised iron powder coated inverted T or L section (concealed Gi frame work) of mettalic or equivalent suspended from ceiling with provn of galvanised wire 4 mm dia and wall taping screw including butterfly clip, hold down clips for fixing the board to frame complete all as per manufacurers instructions all as directed and specified. (a) size of main tee 39 x 24.4 x 0.8 mm (b) size of wall angle 22.2 x 22.2 x 0.65 mm (c) size of grid 0.61 x 0.61 mm S&F in repair 2-in-1 CP bib cock
Contract Date: Feb 13, 2026 Contract Value : 23.04 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
Uttar Pradesh View Result →
42.
Defence #9504950 AOC
MAINTENANCE / REPAIR / REPLACEMENT OF INTERNAL ELECTRIFICATION AND OTHER ALLIED E/M & B/R WORKS IN BSO YARD, MT GE OFFICE COMPLEX, OLD TELEPHONE LINE, OFFICERS MESS, NP LINE, NGBM, OGBM OFFICERS MARRIED ACCN AND OTHER CONNECTED AREA UNDER AGE E/M-I OF GE SOUTH PUNE; 1 Labour only for repair / maintenance of internal light fitting of any typelike tube lights / wall bracket light fittings / ceiling lights / bulk head light / mirror lights etc in its position, testing all the components / parts, wiring etc, identifying and taking out the defective components like holders, lamps etc complete all as directed by Engr-in-charge. Note:(i). Attending of one number complaint and make it functional, shall be measured as one job.(ii)Spares like capacitor, lamp holder, connector, connection wire etc. replaced against above mentioned item will be measured & paid for separately as S&F under respective items of BOQ.(iii)The contractors representative will report to concerned JE E/M at 0900hrs daily to collect the list of defects and will submit the completion report on following day before 0900hrs to the JE E/M & Engr-In-Charge. 2 (iv) The contractor shall rectify the defects and make the light fittings functional within 24 hours from the time the list of defective lights is handed over to him / his rep by the concerned JE E/M.In case the light fitting is not made functional for whatsoever reason within the specified time limit, an amount of Rs 100/- per such defective light fitting per day will be recovered from the amount due to him through RAR / Final Bill.The contractor shall engage separate team of technicians / repairerwith helperfor each at AICTS, 64 EME BN and other connected area.(v) The contractor shall maintain proper record of repair / maint in a binded compliant register and complaint slip books duly signed by the user and bringing out the details of spares replaced and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every Monday or as and when asked for. (vi) The contractor shall maintain sufficient stock of spares / material required for repair / maintenance of light fittings. 3 S&F of Lamp Holder, insulated body, with back plate for batten fitting include complete all as specified and directed. 4 S&F modular fivestep type fan regulatorup to 120W, 2 modulesuitable for existing modularframe complete all as specified and directed. 5 S&F modular switch 10 amps one way one module complete all as specified and directed. 6 S&F modular switch 10 amps two way one module complete all as specified and directed. 7 S&F modular switch piano type 20 amps one way one module with neon indicatorcomplete all as specified and directed. 8 S&F modular Bell Push 6 Amp amps one way one module with neon indicatorcomplete all as specified and directed. 9 S&F modular Socket, 6A - 2/3 pin,2 module complete all as specified and directed. 10 S&F modular Socket, 6/16A - 2/3 pin, 2 module complete all as specified and directed. 11 S&F of 1 module Blanking plates complete all as specifed and directed by Engr-In-Charge. 12 S & Fof switch piano flush type 5 Amps SP one way complete all as specified and directed 13 S & Fof switch piano flush type 15 Amps SP one way complete all as specified and directed 14 S & F ofmodular switch socket combination 6 Amps flush mounted 2/3 pin, multi purpose, 3 module, complete all as specified and directed 15 S & F ofmodular switch socket combination 16 Amps flush mounted 2/3 pin, multi purpose, 3 module, complete all as specified and directed 16 S & F ofswitch socket combination 5/15 Amps flush mounted3/5 pin multi purpose complete all as specified and directed 17 S & F ofswitch socket combination 5/6 Amps flush mounted3/5 pin multi purpose complete all as specified and directed 18 S&F ofsocket outlet, 5/6 Amps flush mounted2-in-1, 3 pin, complete all as specified and directed 19 S&F ofsocket outlet, 5/15 Amps flush mounted2-in-1, 3/5 pin, complete all as specified and directed 20 S&Ffor ceiling rose, 2 to 3 terminals /PVC / Polycarbonate, isolated body complete all as specified and directed 21 S&F offan regulator (socket type) electronic type, five step, suitable for 1200/1400 mm sweep fan as per the sample provided by the Engr-in-charge. 22 S&F of door bell AC 230 volts single phase ding dong type complete all as specified and directed. 23 S&F bell push, flush type 5 Amps complete all as specified and directed. 24 S & F ofswitch socket combination with box 5/6 Amps surface mounted 5 pin multi purpose complete all as specified and directed 25 S & F ofswitch socket combination with box 6/16 Amps flush mounted3/5 pin multi purpose complete all as specified and directed 26 Taking down carefully aluminium / copper point wiring with surface/ concealed PVC conduit or wooden batten ( light, fan, socket, bell or power ) including sunk in cast iron / pressed steel terminal boxes except fitting such as switches, ceiling roses, lamp holders, sockets, regulators, call bells, light fittings of any sketch etc and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engr-in-Charge. 27 M&L for point wiring with 1.5 sq mm copper conductor FRLSH (multi-stranded) PVC insulated ISI marked unsheathed cable and including surface, Non metallic rigid PVC casing capping double lock type / PVC conduit ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unsheathed FRLSH cable size 1.5 sq mm copper conductor as earth wire to common earth dolly including PVC box, modular cover plate with frame suitable for modular type switches, sockets, fan regulator etc for One light/Fan point controlled by one way switch 6 Amps 240 volts, complete all as specified and directed. 28 All as per item no. 26 above but One 3 pin 6 Amps socket out let point on independent board, complete all as specified and directed 29 All as per item no. 26 above but One 3 pin 6 Amps socket out let point on same board, complete all as specified and directed 30 All as per item no. 26 above but One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sq mm size, complete all as specified and directed 31 All as per item no. 26 above but One light point controlled by Two 2-way switches, complete all as specified and directed 32 M&L for point wiring with 2.5 sq mm copper conductor FRLS (multi-strand) PVC insulated ISI marked unsheathed cable and including surface, Non metallic rigid PVC casing capping double lock type ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unsheathed FRLS cable size 2.5 sq mm copper conductor as earth wire to common earth dolly including PVC box , modular cover plate with frame suitable for 15 Amps socket and switch outlet power point independent circuit, complete all as specified and directed. 33 M&L for securingloose wiring and repair to point wiring with including necessary rigid non metallic PVC casing caping double lock type/ PVC conduit ISI marked of size not less than 25 mm inclusive all accessories complete as specified and directed. 34 S&F of flexible conduit pipe ivory grey in colour of dia not less than 25 mm rigid non-metallic, exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc, complete all as specified and directed. 35 M&L for sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 1.5 Sqmm, 1100 Volts grade in and including PVC Conduit /casing capingmedium grade not less than 25 mm complete with conduit accessories and copper cable 1.5 sqmm, FRLSH, continuous earth wirecomplete all as specified and directed.Note:- Two runs of 1.5 Sqmm cable with 01 run of 1.5 Sqmm earth wire along with casing caping / conduit shall be measured as one RM 36 M&L for sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 2.5 Sqmm, 1100 Volts grade in and including PVC Conduit /casing capingmedium grade not less than 25 mm complete with conduit accessories and copper cable 2.5 sqmm continuous earth wirecomplete all as specified and directed.Note:- Two runs of 2.5 Sqmm cable with 01 run of 2.5 Sqmm earth wire along with casing caping / conduit shall be measured as one RM 37 M&L for sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 4 Sqmm, 1100 Volts grade in and including PVC Conduit /casing capingmedium grade not less than 25 mm complete with conduit accessories and copper cable 4 sqmm, FRLSH, continuous earth wirecomplete all as specified and directed.Note:- Two runs of 4 Sqmm cable with 01 run of 4 Sqmm earth wire along with casing caping / conduit shall be measured as one RM 38 M&L for sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 6 Sqmm, 1100 Volts grade in and including PVC Conduit /casing capingmedium grade not less than 25 mm complete with conduit accessories and copper cable 6 sqmm, FRLSH continuous earth wirecomplete all as specified and directed.Note:- Two runs of 6 Sqmm cable with 01 run of 6 Sqmm earth wire along with casing caping / conduit shall be measured as one RM 39 M&L for sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 10 Sqmm, 1100 Volts grade in and including PVC Conduit /casing capingmedium grade not less than 25 mm complete with conduit accessories and copper cable 10 sqmm, FRLSH continuous earth wirecomplete all as specified and directed.Note:- Two runs of 10 Sqmm cable with 01 run of 10 Sqmm earth wire along with casing caping / conduit shall be measured as one RM 40 Taking down carefully sub main wiring of any type and size and making good disturbed surfaces , complete all as specified and directed. 41 S&F 1100 volts grade heavy duty cable 4 Sqmm two core PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0 m apart including 4mm suspension wire, one twin core cable flat or circular, complete all as specified and directed. 42 S&F in replacement factory made epoxy powder coated Distribution Board TP & N 4way double door (VTPN MCCB DB ) MCCB as In comer, with metal door (IP-43 protection) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout semi flush to wall and making good disturbed surface and touch up with the same finishes complete all as specified and directedNote:- MCBs/ MCCBs will be measured and paid separately under respective items of BOQ 43 S&F in replacement MCB DB 12 way SPN double door sheet metal enclosure factory made suitable for MCB DBs 240 volts with 200 amp rated bus bar, neutral & earthing link bar, surface mounting complete including taking down the existing DB of any type & size along with its accessories by removing from existing circuits and re-fixing the new DBs and circuits complete as required at site complete as specified and directed by the Engr-in-Charge.Note - MCBs will be measured & paid separately under respective items of BOQ 44 S&F in replacement MCB DB 8 way SPN double door sheet metal enclosure factory made suitable for MCB DBs 240 volts with 200 amp rated bus bar, neutral & earthing link bar, surface mounting complete including taking down the existing DB of any type & size along with its accessories by removing from existing circuits and re-fixing the new DBs and circuits complete as required at site complete as specified and directed by the Engr-in-Charge.Note - MCBs will be measured & paid separately under respective items of BOQ 45 S&F in replacement MCB DB 4 way SPN double door sheet metal enclosure factory made suitable for MCB DBs 240 volts with 200 amp rated bus bar, neutral & earthing link bar, surface mounting complete including taking down the existing DB of any type & size along with its accessories by removing from existing circuits and re-fixing the new DBs and circuits complete as required at site complete as specified and directed by the Engr-in-Charge.Note - MCBs will be measured & paid separately under respective items of BOQ 46 S&F in replacement MCB DB 2 way SPN single door sheet metal enclosure factory made suitable for MCB DBs 240 volts with 200 amp rated bus bar, neutral & earthing link bar, surface mounting complete including taking down the existing DB of any type & size along with its accessories by removing from existing circuits and re-fixing the new DBs and circuits complete as required at site complete as specified and directed by the Engr-in-Charge.Note - MCBs will be measured & paid separately under respective items of BOQ 47 S&F MCCB with rating of 100 Amps, 415 Volts, 3 pole with 16 kA breaking capacity, thermal magnetic adjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity (Icu), MCCBshould be with suitable spreaders and phase barriers for each terminals complete as specified and directed 48 S&F in repairs MCCB with rating of 63 Amps, 415 Volts, 3 pole with 16 kA breaking capacity, thermal magnetic adjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity (Icu), MCCBshould be with suitable spreaders and phase barriers for each terminals complete as specified and directed 49 S&F in replacement of sheet metal enclosures single pole and neutral with a two pin and earth plug and socket complete incluidng with one single pole MCB 20 Amps, 240 volts with all accessaries etc complete all as directed by Engr-in-charge. 50 S&F in replacement metal clad plug top 3 pin, 20 Amps, 230 volts, ISI marked heavy duty suitable for geyser connection cord complete all as specified and directed. 51 S&F in replacement of neon lamp indicator square / round type including taking down old unserviceable neon lamp complete all as specified and directed. 52 M&L for earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to galvanised earth lead wire 4.0mm diafor earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part-I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC (1:2:4, Type B1) as in Pit and RCC 1:2:4, Type B1 as in cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.Note : GI earth wire and GI protection pipe up to 7.50 m length shall be included in unit quoted rates of this item 53 S&F in replacement heating element of capacity 2 KW of any type and shape suitable for existing 25 ltrs capacity geysers as per sample provided by Engr-in-Charge complete all as directed. 54 S&F in replacement of C Curve MCB SP 6-32 Amps working on 240 volts, 50 Hz 10 KA, complete all as specified and as directed. 55 S&F in replacement of C Curve, MCB SPN, 6-32 Amps working on 240 volts, 50 Hz 10 KA, complete all as specified and as directed. 56 S&F in replacement of C Curve MCB SPN 40-63 Amps working on 240 volts, 50 Hz 10 KA, complete all as specified and as directed. 57 S&F in replacement of C Curve MCB TP 25-63 Amps working on 240 volts, 50 Hz 10 KA, complete all as specified and as directed. 58 S&F in replacement of C Curve MCB TPN 40-100 Amps working on 240 volts, 50 Hz 10 KA, complete all as specified and as directed. 59 Taking down ceiling fan / exhaust fan of any sweep for servicing / repairing / maintenance, opening up, identifying and replacing the defective parts, cleaning, greasing etc, re-assembling and hanging up / re-fixing back at its original position, connecting up and testing complete all as directed.Note:- Cost of spares such as capacitors, bearings etc will be measured and paid for separately under respective Item of BOQ as supply only. 60 Supply only bearing No.6201/6202/6203 or any other No matching to the existing size and suitable for ceiling fan/exhaust fan/wall mounted fan, complete all as specified and directed. Make:- SKF or equivalent 61 Supply only capacitor of 2.5 mfd for ceiling fan / exhaust fan, complete all as specified and directed.Make:Tibcon/Epcos/Havells 62 S&F in replacement of aluminum fan blades suitable for heavy duty exhaust fan of any sweep as per the sample complete all as directed by Engr-in-charge 63 M&L for removing of burnt winding of ceiling fan’s motor of celling fan of size 1200/1400mm sweep, and rewinding of the same with super enamelled copper winding wire of suitable gauge or of matching size to the existing wires including all insulating material such as insulation paper sleeve, tape, varnishing etc. and reassembling, testing, transporting back to site and re-fixing to original position complete all as directed by Engineer-in-charge. 64 All as per item no. 62 above but Exhaust fan of 300 mm sweep, complete all as directed by Engineer-in-charge 65 Dismantling and removing rusted louvers (set of 4) and S&F new mild steel louvers duly painted gray colour synthetic enamel paint suitable for 300mm heavy duty exhaust fan along with four number mounting bracket with bolts, nuts washers etc complete all as directed by Engineer-in-charge 66 Supply and fixing of exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 150m including replacing of plywood as per site requirement, complete all as directed by Engineer-in-chargeNote:- Old Exhaust fan will be deposited in MES store yard by the contractor without any extra cost to the Department. 67 Supply and fixing of exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 200m including replacing of plywood as per site requirement, complete all as directed by Engineer-in-chargeNote:- Old Exhaust fan will be deposited in MES store yard by the contractor without any extra cost to the Department. 68 Supply and fixing of exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 250m including replacing of plywood as per site requirement, complete all as directed by Engineer-in-chargeNote:- Old Exhaust fan will be deposited in MES store yard by the contractor without any extra cost to the Department. 69 Supply and fixing of exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 300m including replacing of plywood as per site requirement, complete all as directed by Engineer-in-chargeNote:- Old Exhaust fan will be deposited in MES store yard by the contractor without any extra cost to the Department. 70 S&F PVC unbreakable surface boxes of size 4x4, complete all as specified and directed 71 S&F PVC unbreakable surface boxes of size 6x6, complete all as specified and directed 72 S&F PVC unbreakable surface boxes of size 4x7, complete all as specified and directed 73 S&F PVC unbreakable surface boxes of size 6x8, complete all as specified and directed 74 S&F PVC unbreakable surface boxes of size 8x10, complete all as specified and directed 75 Taking down carefully and re-fixing geyser of any size / make after doing the necessary repair works with necessary fasteners /clamps and making good any disturbed surface complete all as directed by Engr-in-charge 76 S&F in replacement of thermostat and cutout set electronic type, temperature adjustable from 0-80⁰C suitable for geyser of 25 ltrs capacity, complete all as directed by Engr-in-charge. 77 Disconnecting and taking down existing unserviceable geyser of 25 ltrs capacity of any make / brand, carrying over the same to civil workshop for repairing & welding etc.Opening the geyser and dismantling of all parts and taking out inner tank / container, removing dents and making it to shape including welding / brazing to the leakage portion and S&F filling of new glass wool in between inner tank and out casing of geyser. Re-assembling and carrying back to site the geyser and painting to outer casing of geyser with two coats of superior quality synthetic enameled paint after preparation of surfaces and re-fixing to its original location complete all as directed by Engr-in-charge 78 S&F in replacement of NRV valve of size 15mm dia of Brass complete all as specified and directed. 79 Supply & fix in replacement 15/16 Amps plug top, 3 pin,230 V, ISI marked, suitable for geyser connection cord, complete all as specified and as directed 80 S&F in replacement of white cover plate with frame 2 module, complete all as specified and directed by Engr-in-charge. 81 S&F in replacement of white cover plate with frame 3 module, complete all as specified and directed by Engr-in-charge. 82 S&F in replacement of white cover plate with frame 4 module, complete all as specified and directed by Engr-in-charge. 83 S&F in replacement of white cover plate with frame 6 module, complete all as specified and directed by Engr-in-charge. 84 S&F in replacement of white cover plate with frame 8 module, complete all as specified and directed by Engr-in-charge. 85 S&F in replacement of white cover plate with frame 12 module, complete all as specified and directed by Engr-in-charge. 86 S& F in replacement PVC unbreakable surface boxes suitable for modular switches 1 or 2 module, complete all as specified and directed. 87 S& F in replacement PVC unbreakable surface boxes suitable for modular switches 3 module, complete all as specified and directed. 88 S& F in replacement PVC unbreakable surface boxes suitable for modular switches 4 module, complete all as specified and directed. 89 S& F in replacement PVC unbreakable surface boxes suitable for modular switches 6 module, complete all as specified and directed. 90 S& F in replacement PVC unbreakable surface boxes suitable for modular switches 8 module, complete all as specified and directed. 91 S& F in replacement PVC unbreakable surface boxes suitable for modular switches 12 module, complete all as specified and directed. 92 S&F in replacement of 3mm thick white coloured hylam sheet (bakelite) for mounting switches complete all as directed 93 S&F in replacement of GI pipe bracket of 25 mm dia 1.0 m long bend to shape for street light fitting made out of 25 mm dia GI light grade pipe fixed on pole using suitable FI clamp including necessary new nut, bolt and washer complete all as specified and directed 94 Supply and fixing in repair LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics and should have supporting LM 79 & LM 80 test certificate from Government approved NABL accredited Lab with IP 65/66 protection complete all as specified and directed by Engr-in-Charge 95 S&F in replacement of1x10watt,230V , / Min 100 lms/w surface and wall mounted LED batten suitable for mirror light with Aluminium housing, glare free and integrated electronic driverincluding connecting up with twin core twisted flexible copper conductor cable from ceiling rose all as specified and directed by Engr-In- Charge 96 Supply and fixing in replacement round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light minimum 100 lms/w complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engr-in-charge 97 S&F in replacementofrecess type LED ceiling lights 15 W LEDwith ceiling cut out of Ø 170 mm, 6000K recess mounted down lighter with separate replaceable electronic driver including connecting with twin core wire, including cutting the existing false ceiling dia to the required size and also matching to the adjacent false ceiling surfaces carefully complete all as specified and directed. Make:- Luker /Havells / Crompton 98 Supply & fixing in replacement of LED fixture 18 watt surface mounted ceiling light 5700K with diffuser to give glare free light of size 300x300 mm, Min 100 lms/w powder coated CRCA housing with compatible driver complete all as specified & directed by Engr-in-Charge 99 Supply & fix in replacement of LED fixture 36 watt surface mounted ceiling light 5700K with diffuser to give glare free light, Min 100 lms/w powder coated CRCA housing with compatible driver complete all as specified & directed by Engr-in-Charge 100 M&L for painting of ceiling fan of any sweep with two coats of synthetic enamel paint by rubbing / removing the old paint carefully without any damage to the fan or fan blades etc complete all as directed by Engineer-in-charge. 101 M&L for painting of exhaust fan of any sweep with two coats of synthetic enamel paint by rubbing / removing the old paint carefully without any damage to the fan or fan blades etc complete all as directed by Engineer-in-charge. 102 Taking down cement plaster (From any height) from old brick / stone masonry walls etc. including racking out joints, hacking for keys and scrubbing down with water complete all as specified and directed. 103 M & L 15 mm thick rendering in cement mortar 1:6 on fair face of brick work or concrete surfaces, surface finished even and smooth with out using extra cement, complete all as specified and as directed. 104 M&L for preparation of old plastered / decorated wall surfaces by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and appyling one coat of distemper oil emulsion including necessary scafolding and safety measures as required at site complete as specified and as directed by Engr-in-Charge. 105 S&F in replacement Brass chrominum plated connection 15 mm dia 600 mm long (heavy duty) with 2 Nos brass chrominum plated nuts and washer suitable for geysers of 25 ltr capacity complete all as specified and directed by Engr-in-Charge. 106 S&F in repairs FRP, water proof, weather proof, sock proof single phase electric meter box of size 250x250x155 mm with front side glass window, surface mounting type with connected accessories complete all as specified and directed by Engr-in-Charge. 107 S&F in repair FRP, water proof, weather proof, sock proof three phase electric meter box of size min 400x300x200 mm with front side glass window, surface mounting type with connected accessories complete all as specified and directed by Engr-in-Charge. 108 Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapour group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminium hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-Charge. 109 Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. 110 M&L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed by Engr-in-Charge. 111 Supply and fixing in replacement 2x2 feet, 36 Watts, white powder coated CRCA housing recessed type with in built PIR sensor can detect motion from 5 mtr heightwith high efficiency PMMA diffuser soft glare free light,5700 K, min 100 lms/w complete with drivers, for roof ceiling including connecting up with three core flexible copperconductor cable of suitable size complete all as specified and directed by Engr-in-charge. 112 Supply and fixing in replacement 2x2 feet, white powder coated CRCA housing recessed type with optional pre-set colour temperature or manual adjustments to any CCT in the productivity range 3000K-6500K along with dimming range 10%-100% controlling of the luminaire is possible by wirelessly with app based control & remote control including drivers and remote, for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as speciifed and directed by Engr-in-charge. 113 S&F in replacement Decorative, wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 9 W LED lamp B22 base including 01x9 W LED bulb (warm white) and connecting up with twin core twisted flexible copper conductor cable from ceiling rose complete all as specified and directed by Engr-in-Charge. 114 S&F in replacement 1x12 watt, 230V surface mounted LED downlight , Min 100 lms/w Aesthetically designed ultra sleek downlighters with die cast alumimium housing with high efficiency,CW/WW lightincluding connecting up with twin core twisted flexible copper condctor cable from ceiling rosE complete all as specified and directed by Engr-in-Charge. 115 Supply and fixing in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light, Min 100 lms/wcomplete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-Charge. 116 Supply and fix in replacement of exhaust fan, steel bodyAC single Phase, 230V of size 300msweep with blades, and frame etc. complete all as specified and directed. 117 S&F in repair for stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed 118 S&F in replacement of LED tube 20 W, 4 feet length, 6500 k, 120 lms/watt glare free, the LED fitting shall be comply with L70810 Voltage range, PH>0.95, THD<10% and should have supporting LM 79 & LM 80 test certificate from Government approved NABL accredited Lab complete all as specified and directed by Engr-in-Charge
Contract Date: Dec 22, 2025 Contract Value : 24.26 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 9
Maharashtra View Result →
43.
Heavy Industries and Public Enterprises #9486351 Technical Bid
Tender For Construction Of Police Out Post Building At I.A. Trishundi, Distt-Amethi - Excavation in foundation in ordinary soil (Loam, clay or sand) including lift upto including filling watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in- charge upto a distance of 30M. from the foundation trenches. 2 Concrete with 40cm gauge stone ballast, coarse sand and cement in proportion of 10:5:1 in foundations and under floors, including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. 3 M 150 brick work in 1:6 with cement and coarse sand mortar in foundation for including supply of all materials labour, Tools & plants etc, required for proper completion of the work and as per directed by the Engineer-in-charge 4 25mm thick damp proof course with cement coarse sand and 10 mm grade stone grit 1:1.5:3 ratio including water proofing materials in the proportion as specified by the manufacturer including supply of materials, labour T&P etc.required for proper completion of the work. 5 Painting on DPC of over roof slab one coat of air blown bitumen 85/50 or 85/25 @ one kg/sqm including cost of fuel wood other material labour T&P etc, required for proper completion of the work 6 M-150 brick work in 1:6 with cement and coarse sand mortar in super structure for one brick thick wall including supply of all materials labour, Tools & plants etc. required for proper completion of the work and as per directed by the Enoineer-in-charoe 7 Same as item no.6 above but in 1:3 cement and coarse sand mortar in half thick wall. 8 P/L cement concrete with cement approved coarse sand and 2 cm Gaugse stone grit in proportion of 1:2:4 including supply of materials, labouse T&P etc. required for proper completion of the work. 9 RCC work with cement approved coarse sand & 2 cm gauge approved stone grit in proportion of 1:2:4 in lintelal of doors and windows excluding supply of reinforcement and its bending but including its fixing and binding the same with 24 BWG GI binding wire and including necessary cenetring and shuttering etc. & ell materials Labour, T&P etc. required for proper completion of the work . 10 RCC work with cement approved coarse sand & 2 cmapproved stone grit in proportion of 1:2:4 in slab excluding supply of reinforcement and its bending bul chucting its fixing and binding the same with 24 BWG GI binding wire and including necessary cenetring and shuttering etc. & all materials labour, T&P etc. required wpaper completion of the work. 11 Same as item no. 10 above but heavier beams having spans above 6 m. 12 MS or iron in plain work such as RCC or RB work (when not included in an overall rates) wrought to required shapes as necessary including bending for proper completion of the work including supply of steel and wastage. 13 MS or iron in heavy sizes such as built up gate, door frames etc. wrought to required shapes including drilling holes rivitting welding where necessary and also including, supply of steel, nuts, bolts, wastage etc. their xint required for completion of the work. 14 Supply & fixing of steel window and ventilation in required shape & size with open & closed of stay hinges and stopeers elc. comp. including supply of all material, labour and T&P elc. required for proper completion of the work and as directed by the Engineer in charge excluding glass panes.complete. 15 Providing and fixing 3 mm thick glass pan in fixed with brads and putty, including supply of all material, labour and tools and plants etc. required for proper completion of the work 16 Same as item no. 13 above but in squar bar grill and stair case railing as per direction Engineer-in-charge. 17 12 mm thick cement plaster with cement and coarse sand mortar 1:6 over brick work minimum thickness not tobe less than 1 cm including supply of all material, labour and T&P etc. required for proper completion of the work and as directed by the Engineer in charge. 18 Add for etc. labour & material for plaster in rough phase of one brick wall. 19 12 mm thick cement plasterin 1:3 cement & coasre sand mortar complete. 20 12 mm thick cement plasterin ceiling in 1:3 cement & coarse and mortar complete. 21 2.0cm thick cement plaster in dado or skirting 1:2 consisting of one part of cement and 2 part of approved coaste sand finished with 3 mm floating coat of meat cement or cement mized with marble dust in ratio 5:1 including supply of all material labour T&P etc. required for proper completion of the work. 22 Supply & fixing of 32 mm thick commercial quality door shutter including supply & fixing of wooden cleats & stoppers and including fixing adjusment of hinges bolts. locks, handles spring & or other fitting but extending their supply complete with all labour T&P etc. for proper completion of the work. 23 Supply of anodised aluminium fittings like tower, bolts, handles door stopers, L-drop etc.required for door shutter including screws & bolts of approved size and quality and make with all taxes etc. as per direction of Engineer-in-charge 24 2.5cm thick 1:2:4 plain cement concrete floor with cement approved coarse sand and 2cm graded approved stone grit laid in panels finished with 4mm (1/8) floating coat of neat cernent or cement and including 8 cm thick base concrete consiting of cement fine sand of 1.25 FM and brick ballast 4 cm gauge in the proportion of 1:4:8 & removing and overlapping mortar at the pannels if any and giving them uniform finish, including supply of all materials, labour, T&P etc. required for proper completion. 25 Providing and fixing glass strip of 3mm thickness & 22mm deep in joints of floors, flush with floor levels including supply of all materials, labours T&P etc.required for proper completion of the work. 26 Supply & fixing of 10 cm internal diameter AC down pipes compete with rose head bends shoes grating and including supply of necessary MS clamps 25x3mm fixed to walls and includinh 15mm long 6mm dia nails if necessary & supply of all materials labour T&P etc. required for proper completion of the work. 27 Providing & laying brick bat coba 100 mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15 mim to cach other, over 20 mm thick base of cement mortar 1:4 cernent and coarse sand mixed with water proofing compound spreding cement slurry mixed with aerelic cement concrete water proofing compound filled tops of coba & top of coba mortar mixed with water prasting compound in 1:4 cement and coarse sand mortar finished smooth & lop mashed false square 30 cm x30am and side wall parapet shall be monotythic plaster wall upto 30 cm higher and junction and comer shall be rounded by brick ballast cement and coarse sand and masonry coba with top finishing plaster mixing with acetic water proofing compound 2% by weight & including supply of all material labour T&P erc.required for proper completion of the work. 28 Providing & injecting chemical emulsion for pre construction antiterrnite treatment & creating a chemical Barier under the around the column pit, wall trenches sement excavation top surface of plinth filling junction wall and floor along the external perimeter joints Surrounding of pipes and conduit etc. complete (plinth area of the building at ground floor only shall be mecured as per IS 6313) (partlined 1981) adrine emulsifidble concrete of any other approved materials such as hepthachor chlordane will be used. The rate of application of chemical emulsion shall be as follows. 29 Supply & fixing of fen hook. 30 Providing & making drip course in sunshade as per direction engineer incharge including supply of all material, labour, T&P etc, required for proper completion of the work. 31 While washing 3 coats including supply of all materials, Babor T&P etc required for proper completion of the work. 32 One priming coat and tow coat of dry distemper on new work including supply of all materials, labor T&P etc required for proper completion of the work. 33 Finishing wall with water proof cement paint of approved make and quality on new work with 3 coats to give an even shade including supply of all materials, labor T&P etc required for proper completion of the work. 34 Painting of varnishing on new iron or on new wood work with one coat of ready mixed priming paint & two coat of approved superior quality ready mixed paint including supply of all materials, labor T&P etc required for proper completion of the work. 35 Earth work in filling under floor and plinth including cost of th cartage into site ramming dressing and watering lated to the required level as directed by the Engineer-in-charge. 36 Supply and fixing of 24 gauge aluminium sheet on toilet shedter bottom including fixing with aluminium labour and T&P etc required for proper Completion of the work. 37 S/Fof 50mm dia HCI pipe complete. 38 Providing & fixing float ball cock of required size complete with ball and brass rod of superior quality including supply of all materials, labour T&P etc required for proper omplation of the work 39 Providing & foxing fo C.P. brass jali 100 mm dia heavy quality of approved quality including supply of all materials, labour T&P etc, required for proper completion of the work 40 Construction of brick masonary open surface drain 15 cm wide and 20 cm average depth with M 150 brick in cement mortar 1:4 (one cement and four fine sand) including excavalion, 10 cm thick base concrete 1:5.10 ( cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and 25 mm thick cement concrete 1:2:4 (1 cement 2 coarse sand 4 graded stone aggregate 12.5 mm nominal size) for filling haunches Including 12 mm cement plaster 1:4 (1 cement: 4 coarse sand) with a floating coat of neat cement inside the drain its and exposed side including disposal of plus earth complete as per standard design. 41 Sand filling in plinth including supply of all necessary quantity of sand, watering ramming dressing etc. sompleted including lead upto 50m and lift upto 1.5M 42 Construction of Granular Sub Base by providing coarset graded material spreading in uniform layers with layers with motur grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting Vitrattery roller to achieve the desired density complete Cluse 402 including cost of all materials, labour, IXP te required for proper completion of the work. 43 Providing and laying rubber moulded reptective Zig-Zag 80 mm thick interlocking tiles of precast compressed cement concrete of 30 mpa (M-30) compressive strength ISI Marked made by table vibratory method, laid required colour & pattern over 50mm thick compacted bad of fine sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by g plate vibrator, filling the joints with ganga sand and cutting of paver blocks as per required size and pattern finishing and sweeping extra sand in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturers specifications & direction Engineerin-Charge including supply of all imaterial, latiour, T&P etc. as required for proper completion of the work. 44 providing and lixing white vitreous china water closet squatting Orissa patern W.C. pan of size 580 mm X 440 with Bush pipe and overflow arrangernent with 100 en sand cast iron P or S trp. 10 liter low level PVC hing cislem (of approved make) with fitting CUMS ackets, 32 mm diameterflush pipe with fitting and clamps, overflow arrangement with specials and mosquito proof coupling of approved municipal design nctading painting of fittings and brackets cutting and making good the walls and floors wherever required. 45 Providing and fixing white vitreous china laboratory sink tuze (600x 450 x200 mm with C.I. brackets. C.P. brass as complete, including painting of fittings ang ckets Cutting and making good the wall where equired, including supply of all materials, labour and Jools and plants et required for proper completion of the 46 Providing and fixing mirror of rectangular shape and size 463 x 357 mm with plaster molded frame of approved make and shade with 6 mm thick bars board backing including supply of allmaterials, labour and tools and plants etc, required for proper completion of the work. 47 Providing and fixing of 75mm dia sand cast iron S7S pipe soil waste and vent pipes including supply of all maeterial, labour and tools and plants etc required for proper completion of the work. 48 P/F of C.I. Cowl 50mm dia of approvedquality including supply of all materials, labour T& P etc. required for proper completion of the work. 49 providing and fixing CP brass towel rail with the CP brass brackets fixed to wooden cleats with CP brass crews, including supply of all maeterial, labour and tools and plants etc required for proper completion of the work 50 Providing and placing polyethylene water storage tank of approved brand and manufacturer, with cover and suitable loking arrangemrent and making necessary holes for inlet, Outlet and overflow pipes but without Intings and the base suport of tank. 51 Providing and fixing of G.I. pipe 15 mm dia nominal bore complete with g.l. fittings and clamps, including cutting and making good the walls etc. (internal work) complete. 52 Providing and fixing of G.I. pipe 20 mm dia nominal bore complete with g.l. fittings and clamps, including cutting and making good the walls etc. (internal work) complete item. 53 Providing and fixing 15 mm nominal bore C.P. Brass bib cock of approved quality conforming of IS: 8931. 54 Providing and fixing 15 mm nominal bore C.P. Brass Stop cock (concealed) of mixer and geyser points of approved quality conforming to IS: 8931, complete item. 55 providing and fixing 25 mm nominal bore brass Gate Valve of approved quality including suppy of all materials, labour and tools and plants etc, required for proper completion of the work. 56 providing and fixing square mouth S.W. qully tap 100 x 100 mm size P type grade A complete with C.I. grating brick masonry chamber With 1st class brick work 1:4 cement mortar and water tight C.I. cover with frame of 300 x 2300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame tobe not less than 2.70 kg as per standard design. 57 Constructig brick masonry manhole size 90 x 80 cm and 45 cm deep with 1st class brick work in cement mortar 1 4 (tcement: 2 course sand: 4 graded stone aggregate 20 min nominal size, foundation concrete 1:4:8 mix (1) cement 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1,3 (1 cement, 3 coarse sand finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 CEMENT: 2 coarse sand: 4 graded 20 mm nominal size stone grit) finished with floating cont of heat cement complete as per standard design including with frame (Light duty 455 x 610 mm in internal dia mın size total weight of cover and frame to be not less than 38kg (weight of cover 23kg and weight of frame 15 kg) 58 Providing laying and jointing glazed stoneware pipe 100 mm diameter of cement mortar in the mixture of cernent mortar in the proportion of 1:1 (1 cement 1 find sand) including testing of joints etc. complete. 59 Providing and laying cement concrete 1:5:10 (1 cement: coarse and 10 graded stone aggregate 40 mm nominal size) all round SW pipes including bed concrete as per standard design. 60 Providing and fixing sand cast iron trp (100 mndai inlet and 75 mmoutlet) of self cleaning design with sand cast ron screwed down or without vent arm complete, including cost of cutting and making good the walls and Hoors Complete item. 61 Making Khurra 45cm X 45cm with CC 1:2:4 average 5 cam thack including supply of all materials, labour T&P etc. required for proper completion of the work. 62 2.5cm thick 1:2:4 plain cement concrete floor with cement approved coarse sand and 2cm graded approved stone grit laid in panels finished with 4mm (1/8) floating coat of neatcement , without base concrete. 63 Providing & making gola 75x75 mm in c.c 1:2:4 including feushing with cement mortar 1:3 (1 cement 3 fine sand) as per standard design. 64 Making plinth protection 50 mm thick of cement concrete 1,30 (1 cement: 3 coarse sand 6 graded stone aggregate 20mm nominal size) over 75 mm bed of dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sad including finishing the too smooth. 65 RCC work with cement approved coarse sand & 2 cm gauge approved stone grit in proportion of 1:1.5:3 in slab excluding supply of reinforcement and its bending but including its fixing and binding the same with 24 BWG GI binding wire and including necessary cenetring and shuttering etc. & all materials labour, T&P etc. required for proper completion of the work.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
45.
Public Administrative Department #9479203 Technical Bid
Tender For External Electrification And Supply And Installation Of Dg Set For Museum Block At Hussainabad Chetra - H. T. SYSTEM 2 11 KV Incoming System by SEB / Client 3 S.I.T.C. of 11 K V Vacuum Circuit Breaker panel – indoor mounted, self-standing type (with 25KA fault level) conforming to IS: 2156 with degree of protection to IPH3 as per I S 3427. The VCB shall conform to I S 13118 and have a continuous current capacity of 630 Amps (25KA/1 sec) and shall be vertically isolated, horizontally draw-out type, three pole, trip free, complete with 24V D C trip-coil, Auxiliary contact for trip circuit, Spring Charging Motor, C T, P T, metering & protection as required. : Energy Meter with MDI suitable for 200/100/5A/350 MVA (1250 Amp) 4 S.I.T.C. 400 KVA, 11KV / 433V, 50Hz, 3 phase Delta / Star connected ONAN out-door type oil filled transformer with Dyn-11 vector group suitable for floor mounting. The transformer shall have Off Load Tap Changer in steps of 2.5 % from +10 % to -10% and shall conform to IS: 1180 / IS: 2026, 1977, Level II, (latest edition). Transformer shall be complete with: :Oil conservator, Oil cooling fins/tube radiaters fitted on either side of the oil tank containing the HT & LT windings. The windings shall be with copper layered for LT side and Cu foil for HT side with class A insulation. :Transformer - IS : 1180 (Part I) : 2014:Oil - IS : 335 : 1993:HT side of the transformer shall be suitable for cable termination with porcelain bushing conforming to I S: 2099, complete with cable end-box & cable disconnecting chamber and the LT side suitable for Cables termination with Epoxy bushing conforming to I S: 3347 as follows: (MR) 5 :H. T. Side : 1 x 3 C x 120 sq. mm. X LPE cable. 6 :L. T. Side : 2 x 3.5 C x 185 sq. mm. X LPE cable. 7 : Transformer shall be provided with Winding Over temperature indication andtrip devices. 8 : Transformer shall be provided with a Marshalling box with all the wiring for safety, measuring and indicating devices wired and terminated in it. 9 H T CABLE & TERMINATION : 10 Supply and laying of3 core standered aluminium conductor XLPE(Cross linked polyethylene)insulated PVC bedded, Galvanised flat steel strip armoured cables confirming to I.S. 7098 (Part-II with latest amendments) II KV grade at a depth of 900 mm below ground level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks on sides and on top put across. The armouring of cable shall be properly connectedwith earth conductor by clamps etc. (506) 11 :3 C x 120 sq. mm. A2XFY cable. 12 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : (DSR 2022-10.4.2 13 :3 C x 120 sq. mm. 14 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : (DSR 2022-10.5.2) 15 :3 C x 120 sq. mm. A2XFY cable. 16 DIESEL GENERATING / SERVO SYSTEM : 17 S.I.T.C. 415 V, 3 ph, 50 Hz Radiator cooled diesel generator (D G set) used for standby electrical energy generation. TheD G Set shall be SILENT type and shall comprise of: 18  DIESEL ENGINE : 19 - Vertical; multi-cylinder diesel engine of suitable b h pconforming to IS : 10002, 20 :Turbo charged type,:Electronic Governer:Air cooled with water cooled radiator. 21  ALTERNATOR : 22 :Directly coupled alternator conforming to IS: 4722 generating 415 V, 3 phase, 50 Hz, power, 23  Fly-wheel, 24  Common base-frame. 25  Suitable anti-vibration pads of required quantity & size, 26  Silencer shall be residential type, 27  Fuel tank (Day tank) suitable for eight hours operation - complete with fuel level indicator, filler cap, drain valve etc.. 28  Electrical starting and control equipment for electrical starting of D. G. Set with: 29 :Battery charger, 30 :Heavy duty battery set. Battery shall be suitable for at least 3 successive cold starts. 31  Control Panel for control, monitoring & protection ofD G Set. 32 NOTE: As per the Government notification, D G Setshall be enclosed in a canopy meeting the specified NORMS for sound pollution. 33 : 82.5 KVA SDG (MR) 34 : 200 KVA SDG (MR) 35 S.I.T.C. of Automatic Servo Voltage Stabilizer (AVR) of 250KVA capacity with by Pass Arrangement / Panel suitable for UNBALANCED LOAD with automatic voltage control. It shall be indoor, floor mounted and cooled with transformer oil and shall conform to the requirements of latest edition of I S: 9815-pt-1, 1994, I S: 2026-pt-1&2, 1977 and I S: 5142, 1969. AVR shall comprise of Buck–Boost transformer, 3 nos. single phase Servo Controlled Voltage Regulators and Solid state controls, enclosed in a steel container complete with rollers, cables termination arrangement and all the controls mounted in a separate sheet steel enclosure. The AVR shall have following features: (MR) 36 : The input power shall be at 415 - 20% + 10%V, 3 Phase, 4 Wire, 50 Hz. 37 : The Out-put voltage shall be 415 V, Regulation : ± 1 %. 38 : Speed of voltage correction : 17 V / sec or better. 39 : Over load & Short circuit protection with O/L alarm and its acceptance arrangement. 40 : Protection cut-off against Over/Under Voltage. 41 : Single phase protection 42 : Cable terminal Boxes suitable for In-comer & Out-going cables of 2x3.5Cx185 sq mm A2XFY cables or as required. 43 METERING & CONTROLS: 44 : Digital ammeter with selector switch: 2 Nos (I/P-1No + O/P – 1No) 45 : Digital Voltmeter with selector switch: 2 Nos(I/P-1No + O/P – 1No) 46 : Frequency meter: 1No 47 : 3 nos. phase indication lamps. 48 : Auto / manual selector switch. 49 : 3 nos phase voltage correction (increase/decrease) swiches in manual mode. 50 : Out put voltage setting switch in Auto mode 51 : AVR bypass arrangement 52 : Servo-stabilizer shall be complete with first fill of Oil. 53 - 250 KVA Servo stabilizer by pass arrangement 54 -Servo-stabilizer shall be Oil Cooled with first fill of 1000 ltr. Oil.Make: Powertron / Servel /Piyush (PACT) 55 L. T. PANELS 56 D. G. AMF WITH LOAD MANAGEMENT PANEL 57 S.I.T.C Automatic mains failure panel with load management arrangement (PLC-AMF-LM) for 82.5 x 200 KVA DG sets as per SLD. :The Panel shall be free standing, floor mounted, indoor, compartmentalized cubicle, bolted construction, dust & vermin proof, made of Sheet steel (2 mm for doors & 1.6 mm other faces), surface treated with 7 tank process and painted with anticorrosion paint / powder coated in an approved shade. The enclosure shall be IP 52 protected as per BIS. Electrolytic grade Aluminum bus bars shall be insulated with colored heat shrinkable PVC sleeves & supported on SMC / DMC molded supports with anti-tracking barriers. Each section of the AMF-LM panel shall comprise of the metering, annunciation, protection and control functions as required.(MR) 58 :The controls of the AMF panel and the load management sequence as per the SLD, shall be PLC based. The mains failure shall be sensed on incoming side of mains ACB and initiate the starting cycle of D.G. set after an adjustable 0-6 sec delay. The switch over of power between the Mains power and the D G power shall take place with suitably sized (EDO) ACBs in the PLC Panel. After the D.G. set has taken the load, on restoration of mains power, the load shall be connected back to the Mains, however, D.G. set shall continue to run for an adjustable time of 0-10 minutes before switching off. 59 :The PLC shall be compatible to each other and together, control all the D G sets as per the actual load as required. 60 All MCCBs shall have:: Ics = Icu = 100% for the breakers.: MCCBs upto 200A shall be with thermal - magnetic releases and beyond 200A shall be with micro-processor based releases.: MCCBs shall be with extended rotary handle. 61  INCOMER: 62 MCCBs shall be as per SLD as follows with required controls::415 V, 500 A, 4Pole, 50 Hz, MCCB : 2 Nos. (i/c+b/c):415 V, 500 A, 4Pole, Contactor: 2 Nos. (i/c+b/c):415 V, 320 A, 4Pole, 50 Hz, MCCB : 1 Nos. (DG i/c):415 V, 320 A, 4Pole, Contactor: 1 Nos. (DG i/c):415 V, 160 A, 4Pole, 50 Hz, MCCB : 1 Nos. (DG i/c):415 V, 160 A, 4Pole, Contactor: 1 Nos. (DG i/c) 63 BUS BARS::500A TP + N Aluminium suitable for 1.1 K V with a fault level with-stand: 16 K A for 1 second in two parts as per SLD. The Earth Bus shall be of CU & run contnuously throughout the width of the panel. 64  OUTGOINGS : 65 :415 V, 250 A, 4Pole, 50 Hz,MCCB : 2 Nos. 66 :415 V, 200 A, 4Pole, 50 Hz,MCCB : 6 Nos. 67 :415 V, 63 A, 4Pole, 50 Hz,MCCB : 3 Nos. 68 :415 V, 200 A, 3Pole, 50 Hz,MCCB : 1 Nos. 69 :Protection of the feeders as required. 70 : All controls, Annunciations and indications for safe and trouble-free operation of the D G Set.: The operational sequence shall be PLC controlled as per the scheme in the SLD. 71 : 100 KVAR TP Capacitor Bank, Delta connected in (=2*25+4*10+2*5) KVAR units with 7% de-tuned reactor, 440V, 50Hz complete with digital APFC Relay and automatic switching arrangement, suitably sized protection MCCBs/MCBs, Contactors, Auto / Manual selector switches and indicators for selecting the operating mode - all factory wired. Capacitor bank shall be suitable for heavy duty, 480V, 50 Hz, 3 Ph, 4 Wire system. 72 :Class B surge arrester with nominal discharge current(In as per IEC 61643-1) 30KA (for 8/20ms) & Impulse current 7KA(for 10/350ms) between phase to neutral. & 50KA (8/20ms) impulse current for neutral to earth. Maximum continuous operating voltage shall be 320V. Response time (ta) shall be less than 25ns for phase to neutral. Voltage protection level shall be less than 900V at 5KA (8/20ms) for phase to neutral & 1.2KV for neutral to earth. (OBO Bettermann make or equivalent).: 1 No. 73 MDBS & DBS 74 S.I.T.C. Main Distribution Board (MDB) indoor, floor / wall-mounted type, conforming to I S : 13032 (Latest Edition) with key-lockable door; complete with the bus-bars components and accessoriesmounted and wire connections terminated in the board as per SLD & as follows: 75 All MCCBs shall have:: Ics = Icu = 100% for the breakers.: MCCBs upto 200A shall be with thermal - magnetic releases and beyond 200A shall be with micro-processor based releases.: MCCBs shall be with extended rotary handle. 76 MDB L+P+LIFT (MR) 77  INCOMER: 78 :160A (10KA), 4P, 415 V, 50 Hz. MCCB: 1 No.MCCB shall be with digital Voltmeter & Ammeter & LED phase indications as per SLD. 79  BUS BARS : 80 :160A TP + N Aluminium suitable for 1.1 K V with a fault level with-stand: 10 K A for 1 second. The Earth Bus shall be of CU & run contnuously throughout the width of the panel. 81  METERING: 82  OUTGOINGS : 83 :415 V, 50 Hz, 63 A (10KA), 4Pole MCB: 14 Nos. 84 :Class B+C surge arrester Panel Make: Vidyut Control (I) Pvt Ltd / Ambit Switchgear / Tricolite 85 MDB INVERTER (MR) 86  INCOMER: 87 :63A (10KA), 4P, 415 V, 50 Hz. MCB: 1 No.MCB shall be with digital Voltmeter & Ammeter & LED phase indications as per SLD. 88  BUS BARS : 89 :63A TP + N Aluminium suitable for 1.1 K V with a fault level with-stand: 10 K A for 1 second. The Earth Bus shall be of CU & run contnuously throughout the width of the panel. 90  METERING: 91  OUTGOINGS : 92 :230 V, 50 Hz, 40 A (10KA), 2Pole MCCB: 10 Nos. 93 :Class B+C surge arrester Panel Make: Vidyut Control (I) Pvt Ltd / Ambit Switchgear / Tricolite 94 L T CABLE SYSTEM : 95 Supplyandlayingof aluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (pwd 2018/501) 96 4 sq.mm 4 core 97 6 sq. mm 4 core 98 10 sq. mm 4 core 99 16 sq. mm 4 core 100 25 sq. mm 3-1/2 core 101 35 sq. mm 3-1/2 core 102 50 sq. mm 3-1/2 core 103 70 sq. mm 3-1/2 core 104 95 sq. mm 3-1/2 core 105 120 sq. mm 3-1/2 core 106 150 sq. mm 3-1/2 core 107 185 sq. mm 3-1/2 core 108 240 sq. mm 3-1/2 core 109 300 sq. mm 3-1/2 core 110 400 sq. mm 3-1/2 core 111 6 sq. mm 3 core 112 12C x 2.5 sq. mm. 2XWY 113 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring ofthe cable shall be properly connected with the earth as per direction of Engineer-Incharge.(pwd 2018/503) 114 4 sq. mm 4 core 115 6 sq. mm 4 core 116 10 sq. mm 4 core 117 16 sq. mm 4 core 118 25 sq. mm 3-1/2 core 119 35 sq. mm 3-1/2 core 120 50 sq. mm 3-1/2 core 121 70 sq. mm 3-1/2 core 122 95 sq. mm 3-1/2 core 123 120 sq. mm 3-1/2 core 124 150 sq. mm 3-1/2 core 125 185 sq. mm 3-1/2 core 126 240 sq. mm 3-1/2 core 127 300 sq. mm 3-1/2 core 128 400 sq. mm 3-1/2 core 129 6 sq. mm 3 core 130 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. (pwd 2018/504) 131 4 sq. mm 132 6 sq. mm 133 10 sq. mm 134 16 sq. mm 135 25 sq. mm 136 35 sq. mm 137 50 sq. mm 138 70 sq. mm 139 95 sq. mm 140 120 sq. mm 141 150 sq. mm 142 185 sq. mm 143 240 sq. mm 144 300 sq. mm 145 400 sq. mm 146 CABLE TRAYS 147 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.(DSR-2022) 148 :600 mm width X 50 mm depth X 2.0 mm thickness (4.1.7 DSR) 149 :450 mm width X 50 mm depth X 2.0 mm thickness (4.1.6 DSR) 150 :225 mm width X 50 mm depth X 1.6 mm thickness (4.1.3 DSR) 151 PIPES 152 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (DSR-2022) 153 :50 mm(1.21.5 DSR) 154 :32 mm (1.21.3 DSR) 155 Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioningand protective covering etc., complete as required.(DSR-2022) 156 63 mm dia (OD-63 mm & ID-51 mm nominal) (14.16.1 DSR) 157 120 mm dia (OD-120 mm & ID-103 mm nominal)(14.16.3 DSR) 158 EARTHING & LIGHTNING PROTECTION 159 Supply and burying of 600 mm x 600mm x 6.0mm long G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of two no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I pipe and G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonary housing alternate layers of charcoal/coke and salt at alteast 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects.(pwd 218/703) 160 Supply and burying of 600 mm x 600mm x 3mm copper plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 SWG copper wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and copper wire will be extra) 30cm square C.I. frame with hinged cover masonary housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. complete in all respects. (pwd 2018/705) 161 Supply & burrying of 32 mm x 6 mm G I strip from earth electrode directly in ground as required complete in all respects.(pwd 2018/717) 162 Supply & burrying of 32 mm x 6 mm copper strip from earth electrode directly in ground as required complete in all respects.(pwd 2018/718) 163 INTERNAL LIGHTING 164 Supply and fixing of recess mounting round 10 to 15 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. (Pwd 2018/1402) Make: Havells / Signify / LT / Regent / Jaquar 165 Supply and fixing of recess mounting round 15 to 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. Make: Havells / Signify / LT / Regent / Jaquar (Pwd 2018/1403) 166 Supply and fixing of Pendent mounting having 1 X 4 Size 36 to 46 Watt seamlessly intergrateds LED luminier with acrylic sheet diffuser and intergral electronic driver complete in all respects. (Pwd 2018/1416)Make: Havells / Signify / LT / Regent / Jaquar 167 Supply and fixing of water tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP 65 and above Protection . complete in all respect. (Pwd 2018/1417) Make: Havells / Signify / LT / Regent / Jaquar 168 Supply and fixing of 3 Watt LED Path / Walkover Wall Recessed luminaire having powder cotated die cast aluminium body with drive set . Confirming to IP 65 Protection complete in all respect. (Pwd 2018/1441)Make: Litolux / Havells / Signify / LT / Regent / Jaquar 169 S.I.T.C. of 60 kva UPS monolithic with isolation transformer inbuilt, model GI - 60 K, 3 Phase input and 3 Phase output witH 150 AHBattery backup 60 minutes, required suitable size wire complete in all respect as per direction of E/I (M.R.)
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
46.
Housing Urban and Rular Development #9443196 Technical Bid
Tender For Conservation And Restoration Of Munsi Premchandra Museum At Village Lamhi District-Varanasi, 1 Conservation & Restotation of Munsi Premchandra Museum at Village Lamhi District-Varanasi. 2 RESTORATION WORK 3 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm 4 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 5 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 6 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. 7 Careful removal of existing deteriorated/ damaged/ weathered lime plaster without damaging the surface below it. 8 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar 9 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres and below 10 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. 11 Removing white or color wash by scrapping and sand paperingwithout causing damage to the below stone/brick/plastered surface.and preparing the surface smooth including necessary repairs to scratches etc. complete. 12 Removal of all old plumbingInternal & External Pipe including wc, washbasin, taps etc. from toilet & stacking servicealble materials within 50 M lead. 13 Removal of stains, dirt, blackening and other contaminants from Stone by using the solution of Non Ionic soap diluted with water . The soap solution should be mild and the recommeded PH Value is 7. 14 Cleaning of enamel/modern/synthetic paint with help of suitable chemical 15 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 16 Proposal Work 17 Providing and laying lime concrete in footings and bases excluding cost of centring and shuttering With graded stone aggregate 40mm nominal size and mortar comprising of 1 lime putty :1 surkhi : 1 coarse sand 18 Providing and fixing Grouting Material with Lime mortar 1:2 (1 Lime : 2 Coarsesand) cost of required centering complete. 19 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) 20 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) 21 Traditional brick masonry in nanakshahi or lakhori bricks in lime mortar in proportion similar to the existing traditional lime mortar 1:1:1 (lime :1 surkhi: 1 finesand) 22 Traditional Brick work in plainarches in lime mortar 1:1:1 (1 lime : 1 coarse sand: 1surkhi) 23 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; i/c all complete 24 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all completeThermo-Mechanically Treated bars of grade Fe-500D or more 25 Preparation the surface and application:-a) Through cleaning of the grease residuces dishuttering agent, dust, loose materials etc from the surface. b) Loose particle should be cleaned from existing cavities in the concrete. c) Existing construction joint should be opened in a “V” shapetowards the inside, along their entire length, at a depth of 5mm and Providing & laying Doncrete –T single pack naturals Hydrophobic, breathable, flexible water proof render For roofslab conforming to DIN-1048 BS:8102,EN-1504-9, DIN-18550, @10 mm thick. 26 Providing and applying two coats of DONCRETE-LBP single component polyurethane lime Modified liquid waterproofing membrane System, confirming to ASTM C-836 and ASTM C 898. It should have Elongation at Break is 200% as per ASTM i/c all complete 27 30‐40mm lime plaster in two coats with 20mm base coat in lime mortar 1:1:1 (1 lime : 1 Surkhi :1 Coarse Sand)and top coat in lime mortar 1:1:1 (1 lime : 1 Surkhi :1 Fine Sand) 28 Lime concrete terracing on roofswith 25mm nominal size brick aggregate and 50% lime mortar 1:2 (1 Slaked lime : 2 surkhi) rammed and finished with gur and belgiri treatment complete including rounding of junctions with parpaet wall complete 29 Providing and fixing chicken wire mesh (6mm x 6mm) of 24 gauge 200 mm wide along the joints of R.C.C. work and brick work with hooks/nails etc. complete so as to receiving the plastering work over chicken mesh as per the direction of Engineer‐in‐charge. 30 Lime plaster 1:1:1 (1 slakedlime:1 surkhi: 1 fine sand) 20mmThick Double Coat 31 Raking out the joints of country/Nankshahi brick, scooping out dead and decayed mortar very slowly and carfully with scooping rods, then washing complete with hand spray pump. Preparing the surface for replastering including disposal of rubbish with 250m lead 32 40 mm thick rubbed stone flooring over 20 mm (average) thick base of lime mortar 1:3 (1 lime :3 coarse sand) with joints 3 mm thick, side buttered with lime mortar 1:2 (1 lime : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar Red sand stone 33 Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. completeat all levels Granite stone slab colour black, Cherry/Ruby red Area of slab over 0.50 sqm 34 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 35 Supplying, drilling/cleaning hole and fixing appropriate length of ETA Approved HILTI HRD C 10 / RAWLPLUG anchorsuitable for fastenings both on concrete & masonary/aerated blocks. Length of anchor should be decided on the basis of embedment depth in base material, total frame thickness & gap between frame and base material. Anchor comprises of 10 mm diameter Polyamide PA 6 grade sleeve and of 7 mm diameter double threaded 6.8 grade countersunk head double threaded screw made of carbon steel galvanized to minimum 5 microns. CF 125 insulation foams should be used to fill the gaps between frame & base material. Fixing methodology to be followed as per manufacturers guidelines 36 Frame anchor HRD-C 10x140 37 Frame anchor HRD-C 10x100 38 Lime punning with lime putty mixed with Gur,Bilgri,Urd and other ingredients followed by grinding to fine paste for smooth finish 39 French spirit polishing : Two or more coats on new works including a coat of wood filler 40 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 41 Extra for providing and mixing water proofing material in Lime plaster work in proportion recommended by the manufacturers. 42 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) With Chlorpyriphos/Lindane E.C. 20% with 1% concentration Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 43 Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 meter height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 meter centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system i/c all complete 44 Manually removal of vegetation (major trees, climbing plants, creepers) from walls, columns, arches, floor etc in a skilled and careful manner, using appropriate tools and means and without causing any damage to the adjoining parts, i/c all complete 45 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood 46 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Second class teak wood35 mm thick shutters 47 Providing &fixing of 40 mm thick second class teak wood planks frame and 5.5mm thick tinted glass fixed in frame help of beading all necessary T&P all complete in direction of engineer in charge. 48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. 49 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 50 Providing and fixing bright finished brass door latch with necessary screws etc. complete : 250x16x5 mm 51 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 52 (a) 250 mm x 10mm 53 (a) 200 mm x 10mm 54 Providing and fixing bright finished brass handles with screws etc. complete:125 mm 55 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 56 Providing and fixing of cast iron Railing design as per existing character including fixing in wooden member etc all complete in direction of engineer in charge. 57 Repairing ornamental plaster works to match with the existing design using lime plaster (1lime putty:1surkhi) 58 Nano technology based protection technology coating lime wash paint coating lime wash paint Sand Stone Surface/exposed brick work surface / wooden surface with nano technology based paint protection coating to protect porous material against watering staining chlorophyllon aquas based emulsion (Make Narolac/ Ashian/imper guard xp or equivalent) 59 Lime wash / Colour wash with matching original character manufacture to give an even shade : Two or more coats on new work 60 Providing & Fixing of Knauf Fibre Glass Acoustical Suspended Ceiling System with 15 mm thick Optra Microlook 90 Edge Tiles with Knauf Suprafine 15mm face exposed grid. The tiles shall have smooth laminated visual with Humidity Resistance (RH) of 95%, NRC 0.85 – 0.95(Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, Light Reflectance ≥88% as per ASTM E-1477, Colour Pebble White/Black i/c all complete 61 Providing & Fixing of Forbo Flotexcolor/linear series flocked floor covering rolls having a density of 70 million fibres of nylon 6.6 per Sqm , Fire Test EN-13501, Appearence Retention Hexapod ISO 140-8, Friction Slip Resistance Test EN 14041 Class DS, sanitized anti-microbial treatment with resilient waterproof backing ,anti allergiccetrtified by British allergy foundation, anti static, stain resistant, thickness 4.3 mm i/c all complete 62 Providing & fixing 10.5 mm thickengineerwood flooring american exotic bruce 7 layerconstruction,top layer of wood veener 2mm ,plank size width 120 mm ,length 400-1200 mm,Lock & fold locking ,premium finish,micro bevel edges/ends with an underlayment made of natural colour foam,with accessories like end profile,transition profile,reducer ,etc.complete.The profiles are 100% matching. profile at door openings Make-Armstrong/FloorMaster 63 Supplying Testing & Installation of Lift 100 mm Pit or Step ( ONLY 4 INCHES) 2500 mm Headroom, Single Phase Operation (Just 1.4 Kva Power Consumption),Zero Power While Descend, No Side Wall / Column / Beam or Supporting Structure Required, No Machine Room Required / Head Room Required, Safety Curtain in Door 194 safety parameters undertaken Soft Start and Soft Stop Feature Emergency Light, Telephone, 64 Providing & fixingSand Stone single piece slab ornamental benches of approved design pattern (shape) and specifications includingc c 1 :2 :4 grouting, all materials, labor and T & P etc. required for proper completion of work as directed by engineer - in -charge. 65 Providing and fixing sand stone Dustbins in 75 mm thick red sandstone with jali and carvingproperly shaped as per design of approved size, quality and standard specifications withremovable metal bin inside properly fixed to stone body approved design pattern (shape) and specifications includingc c 1 :2 :4 grouting, all materials, labor and T & P etc. required for proper completion of work as directed by engineer - in -charge. 66 INTERNAL ELECTRIFICATION 67 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 68 Wiring for light/ power plug with 2X4 sq. mm FRLS PVCinsulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 69 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 70 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. Earth wire 71 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire 72 4 x 6 sq.mm. + 2 x 6 sq.mm. Earth wire 73 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 74 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 75 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 76 20 mm. 77 25 mm. 78 32 mm. 79 S/F light plug point modular type accessories :- 80 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required 81 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 82 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 83 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 84 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required 85 Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular switches inrecessetc as required 86 Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc as required 87 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 88 4 way (4 + 12), Double door, horizontal type 89 6 way (4 + 18), Double door, horizontal type 90 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required single pole 91 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 92 40 amps. 93 63 amps. 94 Supplying & fixing single pole, blanking plate in the existing MCBDBcomplete etc. as required. 95 Supplying and fixing 20 A, 415 V, TPN Industrial type socketoutlet, with 4 pole and earth, metal enclosed plug topalongwith 20 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 96 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 97 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 98 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 99 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 100 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep 101 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos.blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 1200 mm sweep 102 Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. CAT- AAA 103 Supply and fixing of 12 Watt to 15 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing with extended heat sink, diffuser of Polycarbonate meterial and driver set complete in all respect. CAT- AAA 104 Supply and fixing of recess/ Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA 105 Supply and fixing of recess mounting round 15 to 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA 106 Providing & Fixing of modular plate type white RJ 45 CAT 6 Data outlet / information outlets ETL verified to meet or exceed TIA / EIA category 6 requirements, universal wiring label permitting to either T568A or T568B, UL listed,for computer networkingcomplete in all respect with cover plate, grid plate, screws, MS box, etc with connections as required.1 nos. RJ 45 Data Outlet 107 Supply, Installation, Testing & Commissioning of Led fixture 600mmX600mm 33 W+/- 1W Recess Mounted Decorative Fixture having Light engine and diffuser only on the edeges and hollow in between with Drop Down HET PMMA diffuser fixture with extruded aluminium housing with P.F.>0.95 with THD<10% ,CRI 80,CCT 5700 K.The LED with Useful life of 50000 Hrs at L70.LM29-451-XXX-57-XX. or Equivalent in Philips : Day Space or Trilux : Oplana LED. 108 Supply, Installation, Testing & Commissioning of IP20 led fixture 12 W +/- 1 W LED Recess Mounted Downlighter Round Shapeminimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Housing and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70 .Fixture have Surge Protection 2kV . 109 Supply, Installation, Testing & Commissioning of Led fixture 600mmX600mm 36 W+/- 1W Recess Mounted with PMMA diffuser with having minimum system lumen efficacy of 100lm/W having CRCA housing with P.F.>0.95,THD<10%,CCT 5700 K ,CRI 80.Wipro Cat.No:CRCO10R038HP57GL1 or Equivalent in Philips : RC380B LED36S- 6500 G5 L60W60 PSU OD or Trilux 110 Supply, Installation, Testing & Commissioning of COB LED Track Light 20 Watt having system efficacy of 100 lumen per watt with die cast aluminium housing having CCT of 4000K, .Wipro Cat. No: LD57-251-024-40-XX or Philips or Trilux 111 Supply, Installation, Testing & Commissioning of Single one Meter Track+ Connector . Including all Accessories 112 Supply, Installation, Testing & Commissioning of Cone Shape Led fixture 20 W+/- 1W with Suspended Mounted diffuser with Black Housing and diffused light.Wipro Cat. No:LM45-221-XXX-40-BLor Philips or Trilux 113 Supply, Installation, Testing & Commissioning of Led fixture 600mmX600mm 33 W+/- 1W Recess Mounted Decorative fixture having Light engine and diffuser only on the edges and hollow in between with Drop Down HET PMMA diffuser with Colour Tunning & DALI Dimmable with only extruded aluminium housing. P.F.>0.95 with THD<10% ,CRI 80.The LED with Useful life of 50000 Hrs at L70. The LEDs used in the luminaire shall have variable CCT from 2700-6500 K with CRI of minimum 80. Make : Wipro / Philips / Trilux. 114 Supply, Installation, Testing & Commissioning of IP20 12 Watt Surface Mounted LED Down Lighter having system efficacy of 100 lumen per watt with pressure die cast heat sink having CCT 5700 K only .Wipro Cat. No: LD06-151XXX-57SMG1 orPhilips or Trilux 115 Supply, Installation, Testing & Commissioning of IP66 60 Watt LED Flood Light having system efficacy of 100 lumen per watt with pressure die cast aluminum housing having CCT 5700 K only .WiproCat. No: LF19-711-060-57-XX or Philips or Trilux 116 Supply, Installation, Testing & Commissioning of IP 67 Garden Light having wattage 8 Watt, having pressure die cast housing with minimum beam angle of 36 degree and CCT 2700 K. Fixture is suitablefor only outdoor applicationWipro Cat. No: LD57-251-024-40-XX or Philips or Trilux 117 Supply ofAC230/250 volts, 50 HZ fresh airfansincluding providingnuts, bolts, mounting frame and other accessories etc.complete 300mm sweep 118 Supply of AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting frame and other accessories etc.complete300mm sweep 900rpm 119 Supply,installation, testing and commissioningof Main DistributionBoard suitable for upto 125 amp FP MCCB incomer and single / three phase outgoing MCBs, IP 43 protection, double metal door, factory fabricated, wall mounting type in surface / recess, powder coated, 415 V / 200 amp copper Bus Bar, earth and neutral bar, i/c all complete 8 way TPN 120 Providing and fixing of following rating Four poleMCCBs at the incomer of Main/sub distribution boards withconnections etc. complete as required 100 Amp FP MCCB 116 (KA). 121 Supplying, fixing, connecting, testing and commissioning of followingrating, ISI marked (IS 8828) 240 / 415 volts, 10 KA, Miniature Circuit Breaker (MCB)of single / double / three / four poles in the existing MCB DB or in existing MS enclosure complete in all respects. 122 25 Amp. TP MCB 123 40 Amp.TP MCB 124 63 Amp. TP MCB 125 Design,manufacture, supply,testing and commissioningofMain Panelfabricated out of 14 SWG CRCA sheet steel, IP 42, wall / floor mounting type. The sheet steel shall undergo minimum 9 tank treatment followed by finishing powder coating of min 60 micron thickness. the board includes415 V electrolitic Aluminium Bus Bar, removable gland plates, cable glands,including connection with outgoing feeders completeinall respect. 126 42 nos 32 AMP FP MCB (10 KA) 127 6 nos 32 AMP FP MCB (10 KA) 128 Wiring for light point/fanpoint/exhaust fan point/call bell pointwith 1.5sqmmFR PVC insulated copperconductor single core cablein surface wooden Batten, with Traditional switch, Traditional plate, suitable wooden box and earthing the point with 1.5 sqmm FR PVC insulated copper conductor single core cable etc. as required.(Goup C) (Make:- SSK Heritage Series or Equivalent) 129 Supply and fixing of suitable size Wooden Box with Traditional plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps. Traditional socket outlet and 5/6 amps. switch, connection, painting etc. as required.(Make:- SSK Heritage Series or Equivalent) 130 Supply and fixing of suitable size GI box with Traditional plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6 amps.Traditionalsocket outlet and 15/16 amps. Traditionalswitch, connection, painting etc. as required.(Make:- SSK Heritage Series or Equivalent) 131 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing & fixing 3pin 20 amps modular socket outlet and 20 amps mini SP MCB 3 KA (for ac & gyser), connection, painting etc. as required. 132 Supplying & drawing 2 pair, 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing wooden Batten as required. 133 Supply and fixing offollowingsizes of wooden Batten along with accessories in surface/recess including cuttingthe wall and making good the same in case of recessed conduit as required : 134 20 to 40mm 135 Supplying and fixing following Traditional switch/ socket with Traditional plate & switch box including connections etc. as required.(Make:- SSK Heritage Series or Equivalent) 136 Telephone socket outlet 137 Computer Jack for RJ-45 Socket 138 Supply and fixing of Traditional Type stepped type electronic fan regulator on the existing Traditional Typeswitch box including connections but excluding Traditional Typeplate etc. as required.(Make:- SSK Heritage Series or Equivalent) 139 Supply and fixing Traditional Type blanking plate on the existing Traditionalplate & switch box excluding Traditional plate as required.(Make:- SSK Heritage Series or Equivalent) 140 Supply, installation, testing & commissioning of following pairs of IDF having LSA-Plus disconnection module, back mounting frame & wire manager on good quality power coated MS box with lock & keys. 10 pair 141 FIRE FIGHTING 142 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 143 25 mm dia. 144 32 mm dia. 145 40 mm dia. 146 50 mm dia. 147 65 mm dia. 148 80 mm dia. 149 100 mm dia. 150 Providing, laying, testing & commissioning of B class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required25mm dia 151 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : 152 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. 153 40 mm dia 154 100 mm dia 155 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required 100MM DIA 156 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless flange. 100mm dia 157 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : 158 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 1258520 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 159 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : 160 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 161 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories pendent sprinkler : 162 Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 100mm dia 163 Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1000mm 164 Deduct in item no. 501 (I) 501 (t) and 506 (a) to (f) when cables is passed through G.I./M.S. or Hume pipe in road crossing or along the wall. The cost of the G.I. pipe, hume pipe is to be extra when and where required. 165 16 Sqm. mm 4 core (Rate after deduction) 166 Supply & erection of ISI marked portable fire extinguishers, confirming to IS:15683, wall mounted type, wall brackets complete in all respect as per standard item with all accessories, delivery hose & nozzle whereever required, including fixing on walls as per the directions ofEngineer-in-charge. 167 ABC dry powder Type 6 kg. capacity 168 CO2 gas type. 4.5 kg. capacity 169 Providing & fixing standard carbon steel fireman axe with rubber insulated handle tested to 20000 Volts. 170 Providing and fixing standard fire hose cabinet door with frame (900 mm x 2000 mm ) or (suitable to fit in the duct made of not less than 16 SWG MS sheethavingglass hinged door (5 mm thick glass) including necessary locking arrangement with handle as required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coats of fire red colour). The door shall be fixed in the masonry wall or as required. The words FIRE HOSE to be painted on the box. 171 Providing and fixing weather proof standard fire hose cabinet (750 mm x 600 mm x 250 mm)outdoor typemade of not less than 16 SWG MS sheethaving glassed hinged door (5 mm thick glass) including necessary locking arrangement with handle for housing two nos.15 meter long fire hose pipes, branch pipeas required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coat of fire red colour). The cabinet shall be mounted onself standing mounted type MS Angle iron frame as required. The words FIRE HOSE to be painted on the box. 172 Supply / installation / Testing and Commissioningof Air Release valve (ARV) with forged brass body full way ball valve type isolating valve, flanges / union, suitable for sprinkler / wet riser / down comer system with all necessary connections complete in all respects 173 Supply, fixing, testing & commissioning of 25 mm dia inspecting and testing assembly with gun metal valve, sight glass, by pass valve and connection to the drain line as required to complete the system. 174 Supply, Fixing, Testing & Commissioning of electrical motor driven fire pump, suitable for automatic operation consisting of following : (TERRACE PUMP). 175 (a) Horizontally mounted, end suction type, Centrifugal fire pumpwith operating speed of 2900 rpm, as per IS:1520 complete for delivery of under mentioned discharge against desired mentioned head so as to ensure a minimum pressure of 35 meter at the highest and farthest outlet at the specified flow complete with necessary strainers, 100 mm dia dial pressure gauge of calibration 0-15 kg/sq cm i/c all complete 176 Discharge :1350 liter per minute 177 Head :35 meter 178 Electrical Control panel with starter, 3 Pole motor protection category current limiting type MCCB, indicating light, ammeter, voltmeter, selector switches, CTs, protective fuses, single phasing protection, dry suction cut off etc as required as per standard details. 179 Supply, fixing of CP cap for sprinkler heads to be mounted at false ceiling / vertical. 180 Providing and fixing in positionG.I.pipe sleeves (medium class) of upto 300 mm longduly tack weldedwith the reinforcement of RCC beams /wall and other structural members during the time of casting the same includingpainting with two coats of anti corrosive paint over primer. (for the crossing of sprinkler pipes) 181 80NB 182 100NB 183 150 NB 184 FIRE ALARM 185 Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required. 186 Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. 187 Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. 188 Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required 189 Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. 190 Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & peaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required 191 Supplying, installation, testing & commissioning of maincontrol and indicating panel made out of 16 SWG MS sheetto accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. I/C all complete 192 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm 193 Supplying, receiving, storing, handling, fixing, wiring for fire alarm system wiring using ISI marked (IS 694) 1100 Volts grade, PVC insulated, flexible, flame retardant low smoke (FRLS) copper conductor wire, drawn in existing solid / flexible conduits / casing caping including connections to the detectors, manual call points, hooters, response indicators, accessories, fire alarm control panel etc. includingtermination with bottle type copper lugs, connectors etc as required to complete the system.2*1.5 sqmm 194 Supply and laying of ISI marked Copper conductor PVCinsulated FRLScontrol cable as per IS 1554or XPLE insulated as perIS 7098PVC sheathed1100 volts grade. On surface the cable run shall be fixed by GI clamps etc. i/c all complete. 6*1.5sqmm armoured 195 Providing and fixing of self illuminated / auto glow EXIT signs printed on photoluminescentsheet containing self illuminated base chemical, of appropriate size not less than 300 x 150 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site. 196 PLUMBING 197 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. 198 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required. 199 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 200 32 mm dia 201 40 mm dia 202 Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 203 Providing and fixing white vitreous china flat back half stall urinal of size 580*380*350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in D.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required: 204 Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth. granite stone of approved shade 205 Providing and fixing unplasticised PVC connection pipe with brass unions 15mm nominal bore 206 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15mm nominal bore 207 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards andweighing not less than 690 gms. 15mm nominal bore 208 Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 15mm nominal bore 209 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia 210 Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 211 110mm 212 90mm 213 Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size)around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) 110mm dia 214 Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110mm 215 Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. 216 Bend 87.5 degree 110mm bend 217 Shoe (Plain) 110 mm shoe 218 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 219 Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm 220 Providing and fixing 15cm wide 45cm over all semi circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc. including making necessary connections with rain water pipes complete. 221 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. 222 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. 223 20mm dia nominal outer dia pipes 224 25mm dia nominal outer dia pipes 225 32mm dia nominal outer dia pipes 226 Providing and fixingGI pipes complete with GI fittings and clamps, including cutting and making good walls etc. (internal work). 227 20mm dianominal bore 228 25mm dia nominal bore 229 32mm dia nominal bore 230 40mm dia nominal bore 231 50mm dia nominal bore 232 Painting GI pipes and fittings with SYNTHETIC enamel paint over a ready mixed priming coat, both of approved quality for new work. 233 20mm dia nominal bore 234 25mm dia nominal bore 235 32mm dia nominal bore 236 40mm dia nominal bore 237 50mm dia nominal bore 238 Providing and fixing GI Union in GI pipes including cutting and threading the pipe and making long screws etc. complete (new work). 239 25mm dia nominal bore 240 32mm dia nominal bore 241 40mm dia nominal bore 242 50mm dia nominal bore 243 Providing and fixing gun metal gate valve with wheel of approved quality. 244 25mm dia nominal bore 245 32mm dia nominal bore 246 40mm dia nominal bore 247 50mm dia nominal bore 248 Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license]. 249 Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m. 250 Providing, laying and jointing glazed stoneware pipes grade A with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.100mm dia 251 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all roundS.W. pipes including bed concrete as per standard design 100mm dia sw pipe 252 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. 150mm rcc pipes 253 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150mm rcc pipes 254 Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 255 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm 256 (i) For Sewer Line 257 Size 90X80 cm with FPS bricks (class I ). 258 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design with 20*20mm square bar 259 Providing and fixing on wall face unplasticised Rigid PVC soil and waste water pipes conforming to IS : 13592 Type B including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 260 a) 110mm dia P.V.C. pipe 261 b) 90mm dia P.V.C. pipe 262 Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) 263 P-Trap type Floor Trap 110 x 110mm 264 a) 110mm 265 b) 90mm 266 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. 267 110mm bend 268 90 mm bend 269 110mm 270 90mm 271 90x90x90 mm single tee with door 272 110x110x110 mm 273 Providing & fixing Towel Rail 300mm Long For Wash Basin Area Appoved Make as per direction of engineer / Architect in charge. 274 Providing & fixing Soap Dispenser with Metallic bottleAppoved Make as per direction of engineer / Architect in charge. 275 Providing & fixing Bottle Trap (With Internal Partition) 32mm Size With 250mm & 190mm Long Wall Connection Pipes & Wall FlangeAppoved Make as per direction of engineer / Architect in charge. 276 Providing and fixing Hand Shower (Health Faucet) with 8mm Dia, 1 Meter Long Flexible Tube & Wall Hook (for E.W.C.)Appoved Make as per direction of engineer / Architect in charge. 277 Providing and fixing C.P. brass Two-way angle valve for EWC points & for fixing Ablution Health Fauct of approved quality conforming to15 mm nominal bore Appoved Make as per direction of engineer / Architect in charge. 278 Providing and fixing clean out plug110mm dia 279 LANDSCAPING 280 Providing and stacking of Nauclea cadamba (Kadam) of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge. 281 Providing and stacking of Nyctanthes arbor-tristis (Hasingar) of ht. 90-105 cm in Earthen pots of size 20 cm as per direction of the officer-in-charge. 282 Providing and stacking of Terminalia arjuna of height 150-165 cm. in big polybags of size 25 cm as per direction of the officer-in-charge. 283 Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 284 Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 285 Providing and stacking of Ficus panda of height 90-105 cm. with 10-12 branches and healthy foliage, well formed in cement pots of size 30 cm as per direction of the officer-in-charge.. 286 Providing and stacking of Ficus reginald well branched, bushy of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.. 287 Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushtyshape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.. 288 Providing and stacking of Tradescantia zebrina having in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 289 Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size ofPoly bags & as per direction of the officer-in-charge. 290 Providing and stacking of Asparagus sprengeri of height 30 cm to 45 cm, full of leafy branches in 15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge.. 291 Providing and stacking of Ophiopogon jaburan ( variegated ), full of variegated leaves in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge. 292 Providing and displaying of Croton Petra Bangalore variety having ht. 60 cm to 75 cm with 4 to 6 branches, well developed, fresh and healthy colorful leaves in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. 293 Trenching in ordinary soil up to required depth including removal and stacking of serviceable materials and then disposing of as directed and spreading earth & neatly levelling, breaking clods etc. and making the trenched area with designed mounds, paths and sitting spaces etc. to proper levels by filling with earth or earth mixed with manure and properly watering complete work in required topography as per drawing & specifications. 294 Supplying and stacking of good earth at site including royalty but including carriage1km (earth measusred in stacks will be reduced by 20% for payment). 295 Supplying and stacking at site dump manure from approved source,including carriage up to 1 km (manure measured in stacks will be reduced by8% for payment) 296 Mixing earth and manure in specified proportion or as directed. 297 Rough dressing the trenched ground including breaking the clods. 298 Fine dressing the ground 299 Spreading ofmixed good earth and manure in specified proportions as above and in required thickness. 300 Uprooting weeds from the trenched area after 10 to 15 days after flooding with water including disposal of uprooted vegetation. 301 Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same, as per direction of officer in charge 302 Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. 303 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth,sides of foundation etc. complete. 304 PATHWAY PAVING 305 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. 306 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 307 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixedwith pigment to match the shade of stone and pointing with same mortar. Red sand stone 308 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent 309 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 310 Brickwork with class 150 bricks in Foundation upto plinth levelin Cement & coarse sand mortar 1 : 4 including supply of all materials, labour, T & P and curing etc. required for proper completion of the work 311 EXTRNAL ELECTRIFICATION LIGHTING 312 Supply & Fixingof’ 5mtr long Antique designed pole with cast aluminium/iron base with galvanizedsteel pipe and decorative top painted with primer then painted with dull finished polyurethane paint fitted with MCB and connectorwith decorative bracket single arm for mounting of 1nos drop down lantern with body made out ofspun aluminium and fitted with poly carbonate diffuser in 110W with built in surge protector and lumn output>110lmn/watt. Design as per Architect in charge. 313 Supplying Testing & Installation of Led Flood Light Luminaire 50WPhilips Make Model - BVP 140 Led 50 CW PSU WH/ Wipro/ Luster etc all complete of direction of engineer in charge. 314 Supplying Testing & Installation ofLed Flood Light Luminaire 100WV Philips Make Model- BVP 142 Led 100 CW PSU WH / Wipro/ Lusteretc all complete of direction of engineer in charge. 315 Supplying Testing & Installation of Garden Spike Light 12W WWMake Philips/ Wipro/ Lusteretc all complete of direction of engineer in charge. 316 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required 317 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. 318 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brassn nut bolt & spring washer spaced at 50mm) 319 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 320 6.00 Sqmm 4 Core 321 25.00 Sqmm 3.5 Core 322 70.00 Sqmm 3.5 Core 323 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required. 324 63 mm dia (OD-63 mm & ID-51 mm nominal) 325 90 mm dia (OD-90 mm & ID-76 mm nominal) 326 Suplying installation testing and commissioning of VRV/VRF System i/c indoor outdoor units piping, cabling/bustrunking/ rising main ( within the blinding), wiring, electrical panel and also treated fresh air system. ( 8 USER) 327 INTERIOR WORK 328 HD Projector for Seminar Hall 3000 Lumens (Make Sony/ Samsung) 329 Kiosk for Ticket counter and souvinenier shop 330 Audio System For Seminar Hall (Make JBL/ Bose) 331 Providing & fixing of Gypboards Partition for Green room including fixing with nut bolts washer etc all complete in direction of engineer incharge. 332 P/F Rollar Curtain Blinds 333 Providing & fixing of Glass Railing with stainless steel 900 mm high etc all complete in direction of engineer in charge. (Make Ozone) 334 P/F SIZE=3.5X1.5X1.50MT. (5.00Nos.) Diorama display boxTeak Wooden frameand teak beading finished edges. Including Providing & fixing of6mm Glass on 1 side for display including patch fittings etc all complete in direction of Architect in charge.. Refer Drg. 335 Showcases Providing and fixing Cabinets with 1mm laminate (Century/Formica /Greenmake as/ shade approved by the Architect) over 18 mm Ply water proof (Century/ Green/Duro make), Plywood conforming to international formaldehyde emission standards)and post formed edges finished and duly Melamine/ PU polished on outer surface and inner surface finished with 0.8 mm mica (Century/Formica /Greenmake as/ shade approved by the Architect. The unit shall have cam locks, handles, guides, sliding units, hinges, magnetic catcher’s etc Ozone/ Dorma make of as/design approved by architect Including Providing and fixingof 12 mm thick toughened glass panel of specified size using hardware, patch fittings- namely steel studs as per drawing.etc all complete in direction of architect in charge. Ref. Drg. 336 Design & supply & fixing of Display material has to be printed on LG/Garware/3M Film and pasted on the glass.etc all complete in direction of architect in charge. Ref. Drg. 337 Providng & fixing of Photograpic display panels (Size 600mmx 750mm) 338 Signage 339 Object Interpretation Signage 340 Directional Signege 341 Main Museum signage 342 Utility Signages 343 Display Panel Signage 344 Brochers Design & Printing 345 Curation of museum material (Copy writing of all text to be displayed ) 346 Supplying installation testing and commissioning of IP based CCTV system for building security comprising of PTZ, Fixed camera, cabling, recording, display system and hardware and software support. (Suppliment DSR 2014 Page 6 Item no. 11) 347 Providing & fixing of Public addressal system 348 Cost of Virtual Augementation & Animetronix 3D Robotic Gallary 349 Providing & fixing of room interiors in old personal house depectiong in style of the period of Munshi PremChandra . 350 Bed Room 351 Living Room 352 Kitchen 353 Study Room 354 Other Rooms 355 Cost of Restoration of Object 356 Cost of Creation of Object 357 Cost of Establishment of Lab 358 Cost of External Diorama 359 Research Schollar 360 Copy Writer 361 Conservator 362 Providng & fixing of Touch screen Information kiosk including data cabling wire etc all complete in direction of engineer in charge for reality experience 363 Scalled model of old house (place of birth of munsi Prem Chandra at 1:50 Scale with humen accessbility).
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
47.
Home Affairs #9424820 Technical Bid
Tender For Construction Of 17 Nonresidential Qtrs [Type-Ii/12, Type-Iii/02 & Typ-Iv/03] At Rtc,Itb Police, Sivagangai (Tn); 1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 2 Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kinds of soil. 3 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil. Pipes, cables etc, not exceeding 80 mm dia. 4 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil. Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 5 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 6 Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 7 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :2.35.3 Treatment of soil under existing floors using chemical emulsion@ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 8 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 9 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 10 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. 11 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 12 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level. Concrete of M25 grade with minimum cement content of 330 kg /cum. 13 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level. Concrete of M25 grade with minimum cement content of 330 kg /cum. 14 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). 15 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 16 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 17 Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete 18 Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform 19 Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers. 20 Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns, Pillars, Piers, Abutments, Posts and Struts 21 Centering and shuttering including strutting, propping etc. and removal of form for all heights : Weather shade, Chajjas, corbels etc., including edges 22 Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in superstructure above plinth level up to floor five level in : Cement mortar 1:4 (1 cement : 4 coarse sand) 23 Half brick masonry with non modular fly ash bricks of class designation 10, conformingio IS :12894, in super structure above plinth and upto floor V level. Cement mortar 1 : 3 (1 cement : 3 coarse sand) 24 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab upto 0.50 sqm 25 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab above 0.50 sqm 26 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work 27 Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. 28 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location inmarble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 29 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood 30 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 31 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces 32 Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete :25 mm dia 33 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings /wooden frames with rawl plugs screws etc. 34 Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws 35 mm thick shutters With ISI marked stainless steel butt hinges of required size Second class teak wood 35 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/ clerestory windows & desertory other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall. Frame size 45 x 85 mm 36 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/ clerestory windows & desertory other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall. Frame size 65 x 100 mm 37 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive onboth faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note:stainless steel butt hinges and necessary S.S screws shall be paid separately) 35 mm thick 38 26.89 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white color and other side of board laminted with PVC foil of minimum 14 micron thickness of approved design pasted with hot melt adhesive for cup boards, work stations and bathroom/kitchen cabinet etc. of required sizes comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheathusk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel piano hinges/soft close clip on concealed hinges and necessary S.S screws shall be paid separately) 18 mm thick 39 Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367: Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all comers, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineersin Charge.Wire mesh/Glazing of plain/ toughened/ laminated/ double glass unit with/without high performance coatings as per design requirements and conforming to 15: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for fil Sites with basis wind speed Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for:(i) Sites with basic wind speed> 45m /sec as per IS 875 Part 3 (ii) Sites with structure height more than 20m for all wind speedsmake Fenesta/NCL Veka/Saintgobin.Three track three panels sliding window with twoglazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.Using R3 series with frame (98 mm & above) x (40 mm & above) & both glazed and fly screen sash (30 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-pointlocking system. (Height upto 1.8m).make Fenesta/NCL Veka/Saintgobin. 40 Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367: Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all comers, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineersin Charge.Wire mesh/Glazing of plain/ toughened/ laminated/ double glass unit with/without high performance coatings as per design requirements and conforming to 15: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for fil Sites with basis wind speed Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for:(i) Sites with basic wind speed> 45m /sec as per IS 875 Part 3 (ii) Sites with structure height more than 20m for all wind speedsmake Fenesta/NCL Veka/Saintgobin. Fixed window / ventilator with mullion / transom.Using R4 series with frame (64 mm & above ) x (50 mm & above) & mullion (64 mm & above) x (70 mm & above). (Height upto 0.90 metre) 41 Providing and fixing zinc alloyed (white powder coated) touch lock for uPVC sliding window with necessary screws etc. complete. 42 Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC / Brick / Stone / wood/ Ceramic / Gypsum work by providing weather /structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540- F & ISO 11600 Upto 5 mm depth and 5 mm width 43 Providing and fixing glazing in PVC / aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin- charge. (Cost of aluminum snap beading shall be paid in basic item.)With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) 44 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete With 12 mm mild steel U beading 45 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm 46 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm 47 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :250x16 mm 48 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 300x10 mm 49 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 200x10 mm 50 9Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper 51 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 52 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 53 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 54 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed vitrified floor tiles polished finish of size Size of Tile 800 x 800 mm 55 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm 56 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer ), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm 57 Providing and fixing Ist quality Ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 58 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.110 mm diameter 59 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Bend 87.5° 110 mm diameter 60 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Shoe (Plain) 110 mm 61 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse sand) and making good the wall etc. complete. 110 mm 62 12 mm cement plaster of mix :1 : 4 (1 cement: 4 coarsesand) 63 15 mm cement plaster on the rough side of brick wall of mix : 1: 4 (1 cement: 4 coarse sand) 64 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand) 65 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 66 Wall painting with premium acrylic emulsion paint of interior grade,having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats 67 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre 68 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 69 Painting with synthetic enamel paint of approved brand andmanufacture to give an even shade : Two or more coats on new work 70 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 71 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 72 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid 73 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the wallswherever required:-White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 74 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. 75 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm 76 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and makeas approved by Engineer - in - charge. 77 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 32 mm dia 78 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm dia 79 Providing and fixing 600x450 mm beveled edge mirror of superior nglass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 80 Providing and fixing toilet paper holder : C.P. brass 81 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 82 Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. 83 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes 84 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. External work - Exposed on wall 32 mm nominal dia Pipes 85 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. External work - Exposed on wall 40 mm nominal dia Pipes 86 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore 87 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore 88 Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore (Vertical) 89 Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore 90 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :150 mm diameter 91 Providingmaterial and labour forplacing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 92 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore 93 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore 94 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore 150 mm nominal size square 100 mm diameter of the inner hinged round grating 95 Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid 96 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. 97 Providing and fixing square- mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 180 x 150 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 98 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 99 Extra for depth for Manholes Size 90x80cm With Sewer bricks conforming to IS : 4885 100 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1;2 (1 cement : 2 fine sand) including testing of joints etc. complete: 150 mm dia. R.C.C. pipe 101 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1;2 (1 cement : 2 fine sand) including testing of joints etc. complete: 250 mm dia. R.C.C. pipe 102 Consultancy Services for Architectural, Structural and MEP Services. i.e for carrying out of Geo Tech incesativation preparation of structural drawings,architectural drwaings, desining of MEPdrawings and issuance Good for construction drawings etc on stage wise for smoothful execution of works till finishing of project. 103 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sewerage waste discharge system (IS:13592 : 1992 Marked) of approved quality /make supreme, jain pipes, sudhakar, prince or equivalent 100 mm dia 104 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sewerage waste discharge system (IS:13592 : 1992 Marked) of approved quality /make supreme, jain pipes, sudhakar, prince or equivalent 75mm diameter : 105 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sewarage waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Bend of required degree with access door,100 mm dia 106 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sewarage waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Bend of required degree with access door,75 mm dia 107 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sewarage waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Plain bend of required degree.100 mmdia 108 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sewarage waste discharge system (IS:13592 : 1992 Marked) of approved quality /make. Plain bend of required degree.75 mm dia 109 Wiring for light point/ fan point/exhaust fan point/call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc as required. Group-C (Primary point ) 110 Wiring forgroup controlled (looping) light point /fan point / exhaust fan point/call bell point (without independent switch etc) with 1.5 sqmm FRLS PVC insulated copper conductor cable in surface/recessedPVC conduitand earthing the point with 1.5sqmm FRLS PVC insulated copper conductor single core cableetc.as required.Group-C (looping point ) 111 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 112 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). 113 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 114 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. 115 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required:2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire For Light Extra Loop. 116 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required: 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire For Light Circuit Point 117 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required: 2 X 4 sq. mm + 1 X 4 sq. mm earth wire For Power Circuit Point 118 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required: 4 X 10 sq. mm + 2 X 10 sq. mm earth wire For Submain Wire / Cable of DB 119 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required::4 X 10 sq. mm + 2 X 6 sq. mm earth wire For Submain Wire / Cable of DB 120 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required:100 mm width X 50 mm depth X 1.6 mm thickness 121 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required: 150 mm width X 50 mm depth X 1.6 mm thickness 122 Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness 123 Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness 124 Supplying and installing following size of perforated pre-painted M.S. cable trays reducers with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness 125 Supplying and installing following size of perforated pre-painted M.S. cable trays reducers with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness 126 Supplying and installing following size of perforated pre-painted M.S. cable trays Tee’s with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness 127 Supplying and installing following size of perforated pre-painted M.S. cable trays Tee’s with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness 128 Supplying and installing following size of perforated pre-painted M.S. cable trays cross members with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness 129 Supplying and installing following size of perforated pre-painted M.S. cable trays cross members with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness 150 mm width X 50 mm depth X 1.6 mm thickness 130 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door 131 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with onnections, testing and commissioning etc. as required. Single pole (6/32 Amps) 132 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A 133 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps 134 Supplying and fixing Single Pole Blanking Plate in the existing MCB DB complete Etc. as required. 135 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20mm 136 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm 137 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32mm 138 Supply, fixing, connecting and testing of elephone/computer/TV modular sockets modular plate anodised MS box and blanking late in surface/recessedincluding connectionetc as required. Telephonic Socket outlet 139 Supply, fixing, connecting and testing of elephone/computer/TV modular sockets modular plate anodised MS box and blanking late in surface/recessedincluding connectionetc as required.TV antenna socket outlet 140 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 141 Supplying and fixing modular blanking plate on the existing modular plate& switch box excluding modular plate as required.1 or 2 Module 142 Supplying and fixing folowing modular base & cover plate on exiting modualr metal boxes as etc as required 143 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 144 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. 145 Supplying and fixing PVC batten/ angle holder including connections etc. as required. 146 Supplying drawing, connecting and testing of 0.61mm dia annealed copper conductor PVC insulated PVC sheathed telephone Wire/cables in Existing PVC conduit or a racks as required. 2 pair Telephone cable. (0.61sq mm) 147 Supplying and fixing metal box of following sizes (nominal size) on surface or in reces with suitable size of phenolic laminated sheet cover in front including painting etc as required. 75 mm x 75 mm x 60 mm deep 148 EarthingWithGIpipe4.5mlongX40mmdiai/c accessoriesandprovidingmasonaryenclourewith cover palte having locking arrangement etc with charcoal or coke and salt complete etc as reqd. 149 Providingandfixing25mmX5mmG.I.stripin40 mm dia G.I. pipe from earth electrode including connectionwithG.I.nut,bolt,spring,washer excavation and re-filling etc. as required 150 Pdg.& Fixing 25mmX5mm GI strip onsurface or in recess for connection etc. as reqd. 151 Providing and fixing of lightning conductor finial, madeof25mmdia300mmlong,G.I.tube,having singleprongattop,with85mmdia6mmthickG.I. base plate including holes etc. complete as required. 152 Jointing copper/ G.I. tape (with another copper/G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 153 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapetorsurfaceofwallforlightningconductor complete as required. (For horizontal run) 154 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapetorsurfaceofwallforlightningconductor complete as required. (For vertical run) 155 Supply, Installation, Testingand Commissioning of 1200mmsweep,BEE5starrated,ceilingfanwith Brush Less Direct Current (BLDC) Motor, class of insulation:B,3nos.blades,30cmlongdownrod,2 nos.canopies,shacklekit,safetyrope,copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THDlessthan10%,remoteorelectronicregulator unitforspeedcontrolandallremainingaccessories includingsafetypin,nutbolts,washers,temperature rise=75degreeC(max.),insulationresistancemore than2megaohm,suitablefor230V,50Hz,single phase AC Supply, earthing etc. complete as required. 156 LED Down lighter (SMD Type) (System lumen efficacy ≥120<135lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 400C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).Powder coated die Powder coated die cast /Extruded aluminums Body including trim .22 Watt 157 LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm). 40 Watt 158 Supply ,fixing , testing and commissioning of Exhaust Fan of 300 mm. all accessories as required. 159 Supply ,fixing , testing and commissioning of 2 Ft MIRROR LIGHT. all accessories as required. 160 Supplying, Installation, Testing and Commissioning of Powder coated, 14 SWG CRCA sheet steel enclosed 11 KV H.T. Metering Panel complete with the following:i) 1set of 11/√3KV / 110/√ 3 Volt, 100 VA burden & accuracy class 0.2, single phase construction, dry type cast resin PT. Over voltage factor: 1.2 Continous ii) 3 Nos. of dual core 60/5A, 15 VA burden, accuracy class CL 0.5, 11 kV cast resin CTs iii) One Set of Phase Indicating Lamps. iv) 1 Sets of HRC fuses with fuse base (H.T. Fuse - 1A & LT fuse 2-6A). V) 1 Nos. indoor cable end box for suitable for 3C x 240 sq.mm. 11 kV(E), aluminium conductor XLPE Ar. cable (Incoming & Outgoing cable).vi) Space Provision for 1 No.for SEB approved digital Trivector meter with MDI in KVA of accuracy class - 0.2 for adjustment purpose in Metering Panel - Outdoor Duty Metering cubicle with metering CT, PT, ABT bi-directional meter as per local EB norms Note: The contractor shall get the Trivector meter, CTs& PT tested by SEB in requiredand the charges for liasioning for the same will be in contractor scope. Rate inclusive ofSupply Rate for Metering Panel as described above including installaion, commissioning for metering panel 161 Supply , installation , testing and commissioning of cubical type floor mounted panel suitable for 415 V , 3 phase , 4wire 50 Hz AC supply system of minimum depth 300mm fabricated in compartmentalized design from CRCA sheet steel of 3mm. Thick for frame work and covers , 3mm thick for gland plate i/c cleaning complete with 7 tank process for powder coating in approved shade , having 150 Amp capacity extensible type TPN Aluminium alloy bus bars of high conductivity , DMC / SMC bus bar supports ,with short circuit withstand capacity of 31 mva for 1 set . with 2 no. earth stud , solid connections from main bus bar to switch gears with required size of Al. bus bar making interconnection etc providing and fixingfollowing switch gears :-(Cable entry from bottom ) Incoming :a) 63 Amp 4 Pole MCCB with 25 KA breaking capity - 1 set . b) 3 Nos. Phase indication LED lamps with 2 Amp back up MCB , Breaker ON/OFF indicating light with 2 Amp MCB ,test terminal block set circuit as per standard practic etc as required .Bus Bar :-100 Amp. TPN Al. extensible type Outgoings :i) 16 / 20 Amp 2 Pole MCB - 10 KA -12 Nos.ii) 20 Amp Industrial socket with 2 PoleMCB ( IP 66 )- 10 KA - 2 Nos. iii) 70 Amp TP contactor with NO /NC Contacts - 1 Nos.iv) 24 Hour Time - 1 No. 162 Supplying & laying of following 1100 voltgrade XLPE insulated extruded PVC sheathed aluminium conductor armoured cables as per specification in existing cable trays / Pipe rack ,ducts, over bed of sand, clamped to wall with suitable clamps including, saddles fixing bolts, connecting testing and commissioning. 3.5 C x 95 sq. mm 163 Supplying & laying of following 1100 voltgrade XLPE insulated extruded PVC sheathed aluminium conductor armoured cables as per specification in existing cable trays / Pipe rack ,ducts, over bed of sand, clamped to wall with suitable clamps including, saddles fixing bolts, connecting testing and commissioning. 3.5 C x 70 sq. mm 164 Supplying & laying of following 1100 voltgrade XLPE insulated extruded PVC sheathed aluminium conductor armoured cables as per specification in existing cable trays / Pipe rack ,ducts, over bed of sand, clamped to wall with suitable clamps including, saddles fixing bolts, connecting testing and commissioning. 3.5 C x 50 sq. mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
48.
Defence #9416178 AOC
Tender For Provision Of Oh Tanks Ug Sumps And External Services For Map Ph-Ii Under Ge S Pune And Ge N Pune.; 1 SCH A PART-I TO VII:Note: These schedules are pre-priced by MES and the rate indicated as Rs 0.00 under Col 6 signifies this fact only 2 Total amount of Sch ‘A’ Part I (Building & Structure) 3 Total amount of Sch ‘A’ Part II (Internal Water supply) 4 Total amount of Sch ‘A’ Part III (Internal Electric Supply) 5 Total amount of Sch A Part-IV (Sewage Disposal) 6 Total amount of Sch A Part-V (External Water Supply) 7 Total amount of Sch A Part-VI (External Electric Supply) 8 Total amount of Sch A Part-VII ( LIGHTNING PROTECTION ) 9 Total amount of Sch A Part-VIII (Excavation and Earthwork) 10 SCHEDULE A PART-IX (MISC B/R ANDE/M WORKS)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 6 signifies this fact only. 11 MISC ITEMS E/M WORKS OF INTERNAL & EXTERNALELECTRICAL SUPPLY 12 S&FLEDstreet light luminaire 25 W with pressure die castaluminium housing LED street light luminaries with IP66 with 25 W high power LED, maintenance free system and connecting up with cable, including 1.5 m long GI bracket of required dia, bent to shape, clamp and nut bolts of suitabler size complete all as specified and all as directed. 13 S&F solar powered aviation obstructionlamp complete sysytem make: Altos model AOL-Q-3 SP or equivalent model in philips / Crompton Greaves / bajaj consisting of : (a)LED based avitation obstruction lamp fitting (b) solar panel (c)Battery unit (d) Mounting structure for all above with inter connecting wiring complete all as specified and ditected. 14 Testing and commissioningtransformer copper wound step down, out door type, complete with all standard fitting of capacity 100 KVA, AC 3 phase, 3 wire primary, 4 wire secondary, 50 C/S type HT-22 KV, 3 PH, LT-433 Vand making compete connection of HT and LT Sidewith glands, lugs complete all as specified and directed.(Note- Transformer already installed /mounted on platform at site , before commisioning contractor will carried out Acidity Test,Sludge test, Insulation resistance Test,Break down voltage test of Oil.If test result not meet as per IS standard,contractor will carried out servicing of transformer at site In case of Sphare is out of order andreplacement requiredSphare part of transformer paid sapareatluy under relevent Item. 15 All as per item No- 11.003above but capacity22 KV 200 KVA. 16 Installation, testing and commissioningtransformer copper wound step down, out door type, complete with all standard fitting of capacity 300 KVA, AC 3 phase, 3 wire primary, 4 wire secondary, 50 C/S type HT-22 KV,LT-433 V and making connection on HT & LT side with gland and lugs , The transformer will mount on platform as per manufacturer instruction 0r Typical drawing or of size of size 2.00 M x 2.00 M x 3.50 M deep (1.00 m below GL) withPCC (1:3:6) type C2 and15 cm thick RCC (1:2:4) type B1 for top, reinforced with 10 mm dia TMT bars @ 150 mm C/C complete including excavation & earthwork in any type of strata viz soft/loose/hard/dense/Rock, frame work all as specified and directed(Note- Transformer shall be issued under Sch B free for fixing , before commisioning contractor will carried out Acidity Test,Sludge test, Insulation resistance Test,Break down voltage test of Oil.If test result not meet as per IS standard,contractor will carried out servicing of transformer at site In case of Sphare is out of order andreplacement requiredSphare part of transformer paid sapareatluy under relevent Item.The rate quoted by the contractor shall deemed to be included the cost offoundationa and transportation of transformer from MES yard to work site.No extra payment shall be made on this account.) 17 All as per item No- 11.005above but capacity 11 KV100 KVA. 18 All as per item No- 11.005 above but capacity 22 KV 400 KVA. 19 Servicing of existing LT electrical distribution/control panel of any size and capacity including cleaning of dust and debris, tightening of all connections, checking of contactors/relays, testing of insulation resistance, repair/replacement of defective control wiring (upto 1.5 sqmm copper) and faulty indicators (LED type), Testing and replacement of defective control MCBs upto 63A andensuring full operational status. Complete in all respects as per standard practice and directed by engineer-in-charge 20 Supply, jointing and testing outdoor cable end termination joint (heat shrinkable) suitable for 3 core 185 sqmm 22 KV XLPE cable suitable for earth system complete all as specified and directed. 21 Supply & fix heat shrinkable straight through joint 22 KV XLPE cable suitable for earth system of size 185 sqmm 3 core complete all as specified and directed. 22 M&L Earthing with 600x600x6mm galvanised steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge or the plate at a depth of not less than 1.5 m below ground level, connected to and including galvanised eath strip 32 mm x 6 mm by means of bolts,nuts and check nuts and washers of galvanised steel. Gl pipe 40 mm dia light grade pipe for protection of G.l. earth strip both to be provided to the extent of 7.5 meters as earthing lead and connecting to the eqpt/machinery etc. incl charcoal dust and common salt packed all around the earth plate in alternate layer in the earth pit all as per elctrical plate No. 3 of SSR Part 1·2009 including PCC chamber made up of PCC 1:3 :6 type C1 & RCC Chamer cover of size 540x540x100 mm made with 1:2:4 Type B1 using 6 mm round MS bar & 8 mm MS bar for handle , 20 mm dia medium grade G.I. Watering pipe from top edge of the earth plate upto M.S funnel with wire mesh provided inside the concrete earth pit for watering arrangement including excavation and earth work in any type of soil and testing complete all as specified and directed. 23 Installation testing and commissioning of OUTDOOR TYPE ENCLOSURE, Double door, with angle iron pedastal frame & including steel structure required for installation on cable trench housing cubicle Type, free standing Panel CPRI approved working on 440 V 3 phase 50 Hz, AC supply with aluminium bus bar suitable for 800 Amps fully compartmentalized, dust-proof and vermin proof, 3.15 mm thick CRCA sheet steel enclosure painted asper the 7-tank process & suitable for IP-56 protection, as per section and having the following details and as shown in single line diagrams GE/1668/901:(a) Volt meter 0 – 500 Volt with selector switch – 01 (b) Ammeter 0.1000 Amps with CTs and selector switch – 01. (c) Indication Lamp assembly – RYB LED – 01 set.Incomer : 630 A 4 pole, ACB-02 Nos. Bus coupler : 630 A 4 Pole, ACB -01 No. Outgoing feeders :3 Pole, 315 A MCCB, 50 KA -05 Nos, 4 Pole, 250 A MCCB,35 KA-03, 3 Pole, 200 A MCCB, 35 KA -02Nos, 4 Pole, 100 A MCCB, 25 KA-01 Nos. Panel fabrication & Bus bar for above feeders. (Note- LT Panel with components as above shall be issued under Sch B free for fixing ) 24 Installation, testing & commissioning of OUTDOOR TYPE ENCLOSURE, Double door, with angle iron pedastal frame & including steel structure required for installationon cable trench housing cubicle type, free standing, panel CPRI approved 3 phase, 50 Hz, AC supply with aluminium bus bars, fully compartmentalized, dust-proof and vermin proof, 3.15 mm thick CRCA sheet steel enclosure painted as per the 7-tank process & suitable for IP-56 protection, as per specifications and having the following details and as shown in single line diagrams GE/1968/901 : (Note- LT Panel with components as above shall be issued under Sch B free for fixing )Incomer:160A, 4 pole 25 KA, MCCB with S/C adjustable, O/L & E/F thermal magnetic releases - 01 eachOutgoing Feeders:160A, TP, 25 KA, 415 VoltMCCB withS/C & adj. O/L& E/F thermal magnetic releases - 05 Nos25 KVAR APFC Compartment80A, TPN, 25KA - 1 No, MCCB with fixed neutral and S/C & adj. O/L thermal magnetic release 01 Each8 Stage APFC Relay16A, TPN, 25KA, MCCB with fixed neutral and S/C & adj. O/L thermal magnetic releases (for 5 KVAR Capacitor) 01 Each32A, TP, 25KA, MCCB with fixed neutral and S/C & adj. O/L thermal magnetic releases (for 10 KVAR Capacitor) - 02 NosCapacitor MD - XL 25 Installation testing and commissioning diesel engine/driven generating set of capacity 30 KVA (24 KW) 415 volts 0.8 power tractor at NTP, mounted on base platform with flexible coupling, 1500 RPM alongwith sound proof enclosure (Acoustic Enclosure) designed for reducing the sound level to 7+5 to B(A) (average) IS8528 part - 10 as per approved CPCB norms and as per GSR 371 (E) dated 17.05.2002 with silencer pipe and silencer muffler covered with asbestos rope 25 mm thick independently supported from engine to outside of power house upto 1 mtr, cold start kit, battery start with suitable size of standard dabbles for connecting from DG Set to panel board DG set shall be capable with and including the following:(A) PRIME MOVER: Diesel engine of suitable capacity water cooled (Radiator mounted) closed circuit as per BS-649 or IS-1002 direct injection type with turbo charger. Make: Cummins India Ltd/Kirloskar. The diesel engine shall be capable of running 24 hour continuously with 10% over loading for one hour in every 12 house as per BS 5514/- BS 649/- Engine shall be equipped with all standard fittings as per manufactures recommendations mounted on common base plate/form through flexible coupling with following accessories :(Note- DG Setwith components as above shall be issued under Sch B free for fixing ) (a) RPM cum hour meter(b) Battery Charging Ammeter(c) Ignition key and starting with push buttons(d) Lubricating oil pressure gauge(e) Electronic governor controlling 26 (f) Toggles switch for idle running(g) Oil Tem gauge (h) Water temp gauge(j) Safety control (Trip)(i) High water temperature(ii) Low Lubricant oil pressure(iii) Over speed(k) 24 hours starting equipment comprising with the following:(i) 1 No. 12 volt 180 AH batteries, Make: Exide type 25xnN21 or equivalent as recommended by manufacturer.(ii) Battery charging alternator with built in regulator.(iii) Starter motor assy of suitable capacity.(iv) Battery leads (copper stranded cable) of suitable size with brass thimbles and erminal Make of engine : Kirloskar/Cummings(B) ALTERNATOR: Alternator of capacity 30 KVA/24 KW at NTP, 415 volts, 50 C/S, 1500 RPM, 0.8 power factor, self excited, self regulated, screen protected with self excited field brush rotating fixed designed to be coupled with above engine through flexible coupling. the alternator shall be conformed to 4722 of BS-2613 MAKE: Kirloskar C) CONTROL PANEL : Alternator control panel floor mounted, cubical type with internal wiring with copper conductor for 30 KVA, 415 volts, 3 Phase 4 wire, 50 cycle alternator fabricated out of MS Sheet painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer equipped with the following accessories: 27 (i) AC voltmeter with selector switch 0-500V 01 No.(ii) Ammeter with CT and selector switch of suitable range 01 No(iii) Frequency meter - 01 No.(iv) KW and KWH meter - 01 No.(v) Power factor meter - 01 No(vi) MCCB (for incoming) as recommended by manufacturer - 01 No(vii) Set of copper bus bar of suitable size 01 No.(viii) Set of indicating lamps for 3 phase (RYB) 01 No(ix) Oil Pressure gauge 01 No(D) OTHER FITTINGS: (i) Battery Charger : Battery charger having electric circuit consisting of rectifiers, capacitors and resistance etc. The battery charger should be able to charge 12 volts 180 AH battery 2 Nos at a time(ii) Fuel tank of suitable capacity as per manufacturer recommendation mounted on steel frame at suitable height with all connecting pipes and fittings upto fuel pump and over flow pipe from engine to tank including level indicating gauge duly marked and drain valve and air vent plug etc. (E) Maintenance Spares:(i) Fuel filter element - 02 Nos(ii) Oil filter elements - 03 Nos(iii) Fan Belt - 01 Set(iv) Hose pipe - 01 Set(v) Tappet over gasket - 01 No(F) DG set shall be supplied along with acoustic original enclosure of the manufacture’s suitable for 30 KVA DG Set per CPCB Norms 28 Installation testing and Commissioning of INDOOR TYPE ENCLOSURE with angle iron pedestal frame & including steel structure required for installation on cable trench housing cubicle type, free standing, panel CPRI Approved working on 440 V, 3 Phase50 Hz, AC supply with aluminium bus bars, fully compartmentalized, dust-proof and vermin proof, 2 mm thick CRCA sheet steel enclosure painted as per the 7-tank process & suitable for IP-56 protection, as per section and having the following details and as shown in single line diagrams Ge/1968/905 (Note- LT Panel with components as above shall be issued under Sch B free for fixing )INCOMERFP pole MCCB 250 Amps 35 KA – 02 NosOut Going feeders:TPN pole 16A MCCB, 25 KA – 02 NosTPN pole 20A MCCB, 25 KA – 02 NosTPN pole 63A MCCB, 25 KA – 02 NosTPN pole 100A MCCB, 25 KA – 02 NosTPN pole 125A MCCB, 30 KA – 02 Nos3 KVAR capacitor duty contractor – 02 Nos5 KVAR capacitor duty contractor -02 Nos20 KVAR capacitor duty contractor -02 Nos30 KVAR capacitor duty contractor -02 Nos40 KVAR capacitor duty contractor -02 Nos8 stage APFC relay – 02Nos 29 Installation testing and commissioning diesel engine/driven generating set of capacity 160 KVA (128 KW) 415 volts 0.8 power tractor at NTP, mounted on base platform with flexible coupling, 1500 RPM alongwith sound proof enclosure (Acoustic Enclosure) designed for reducing the sound level to 7+5 to B(A) (average) IS8528 part - 10 as per approved CPCB norms and as per GSR 371 (E) dated 17.05.2002 with silencer pipe and silencer muffler covered with asbestos rope 25 mm thick independently supported from engine to outside of power house upto 1 mtr, cold start kit, battery start with suitable size of standard dabbles for connecting from DG Set to panel board DG set shall be capable with and including the following:(A) PRIME MOVER: Diesel engine of suitable capacity water cooled (Radiator mounted) closed circuit as per BS-649 or IS-1002 direct injection type with turbo charger. Make: Cummins India Ltd/Kirloskar. The diesel engine shall be capable of running 24 hour continuously with 10% over loading for one hour in every 12 house as per BS 5514/- BS 649/- Engine shall be equipped with all standard fittings as per manufactures recommendations mounted on common base plate/form through flexible coupling with following accessories : (Note- DG Set with components as above shall be issued under Sch B free for fixing ) complete all as specified and directed.(a) RPM cum hour meter(b) Battery Charging Ammeter(c) Ignition key and starting with push buttons(d) Lubricating oil pressure gauge(e) Electronic governor controlling(f) Toggles switch for idle running 30 (g) Oil Tem gauge (h) Water temp gauge(j) Safety control (Trip)(i) High water temperature(ii) Low Lubricant oil pressure(iii) Over speed(k) 24 hours starting equipment comprising with the following:(i) 1 No. 12 volt 180 AH batteries, Make: Exide type 25xnN21 or equivalent as recommended by manufacturer.(ii) Battery charging alternator with built in regulator.(iii) Starter motor assy of suitable capacity.(iv) Battery leads (copper stranded cable) of suitable size with brass thimbles and erminal Make of engine : Kirloskar/Cummings(B) ALTERNATOR: Alternator of capacity 160 KVA/128 KW at NTP, 415 volts, 50 C/S, 1500 RPM, 0.8 power factor, self excited, self regulated, screen protected with self excited field brush rotating fixed designed to be coupled with above engine through flexible coupling. the alternator shall be conformed to 4722 of BS-2613 C) CONTROL PANEL : Alternator control panel floor mounted, cubical type with internal wiring with copper conductor for 160 KVA, 415 volts, 3 Phase 4 wire, 50 cycle alternator fabricated out of MS Sheet painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer equipped with the following accessories: 31 (i) AC voltmeter with selector switch 0-500V 01 No.(ii) Ammeter with CT and selector switch of suitable range 01 No(iii) Frequency meter - 01 No.(iv) KW and KWH meter - 01 No.(v) Power factor meter - 01 No(vi) MCCB (for incoming) as recommended by manufacturer - 01 No(vii) Set of copper bus bar of suitable size 01 No.(viii) Set of indicating lamps for 3 phase (RYB) 01 No(ix) Oil Pressure gauge 01 No(D) OTHER FITTINGS:(i) Battery Charger : Battery charger having electric circuit consisting of rectifiers, capacitors and resistance etc. The battery charger should be able to charge 12 volts 180 AH battery 2 Nos at a time(ii) Fuel tank of suitable capacity as per manufacturer recommendation mounted on steel frame at suitable height with all connecting pipes and fittings upto fuel pump and over flow pipe from engine to tank including level indicating gauge duly marked and drain valve and air vent plug etc.(E) Maintenance Spares:(i) Fuel filter element - 02 Nos(ii) Oil filter elements - 03 Nos(iii) Fan Belt - 01 Set(iv) Hose pipe - 01 Set(v) Tappet over gasket - 01 No(F) DG set shall be supplied along with acoustic original enclosure of the manufacture’s suitable for 160 KVA DG Set per CPCB Norms 32 Installationtesting & commissioning of indoor cubic type, free standing floor mounted including of steel structure required for installation on cable trench with base frame, AMF panel CPRI approved on 440 V 3 phase 50 HZ, AC supply. It shall be extendible at both ends, with aluminium bus bars 200 amps capacity fully compartmentalized dust-proof and vermin proof, 2 mm thick CRCA sheet steel enclosure painted as per the 7-tank procress & suitable for IP-52 protection, as per section and having the following details and as shown in single line diagrams GE/1968/094 , complete all as specified and directed.( Note - AMF panel with components shall be issued under Sch B free for fixing ).Incomer100A 4 pole, 25 KA motorized MCCB – 01 NoOutgoingTPN 63 A MCCB, 25 KA – 02 NoTPN 32 A MCCB, 25 KA, 32 A MCCB, 25 KA – 2 NoPanel Fabrication & Busbar for above feeder 33 Installationtesting & commissioningof cubic type, free standing floor mounted weather proof type, pedestal mounted feeder pillar working on 440 V 3 phase 50 Hz, AC supply., It shall be with alum.bus bar 300 amps capacity weather proof dust proof with canopy on top 3.15 mm thick CRCA sheet steel enclosure, painted as per the 7-tank process and painted for outdoor weather proof IP-55 protection installation, as per specification and having the following details and as shown in single line diagrams GE/1968/903 complete all as specified and directed.(Note- LT Panel with components as above shall be issued under Sch B free for fixing )IncomerFP 315 A MCCB,50 KA- 01 NoOutgoingTPN 63A MCCB, 25 KA – 08 NosPanel Fabrication & Busbar for above feeder 34 Installationtesting & commissioningof cubic type, free standing floor mounted weather proof type, pedestal mounted feeder pillar working on 440 V 3 phase 50 Hz, AC supply., It shall be with alum.bus bar 300 amps capacity weather proof dust proof with canopy on top 3.15 mm thick CRCA sheet steel enclosure, painted as per the 7-tank process and painted for outdoor weather proof IP-55 protection installation, as per specification and having the following details and as shown in single line diagrams GE/1968/903 complete all as specified and directed.(Note- LT Panel with components as above shall be issued under Sch B free for fixing )IncomerFP 250 A MCCB,35 KA- 01 NoOutgoingTPN 63A MCCB, 35 KA – 08 NosPanel Fabrication & Busbar for above feeder 35 Supply, Install, testing, and commissioning of outdoor type, enclosure double door with angle iron pedestal frame & including steel structure required for installation on cable trenches, housing cubical type free standing,panel working on 440 volts, 3 phase 50 hz, AC supply with aluminium bus bar,full compartmentalised dust proof and vermin proof 3.15 thcik CRCA sheets steel enclosure, painted as per the 7-tank process & suitable as per IP-56 protection as per specification and having the following details and as shown in single line diagrams GE/1968/901 (Panel for 3 Alexander Road) complete all as specified and directed.a)MCCB 160 amps 4 pole, 25 KAbreaking capacity with short circuit adjustable overload& earth fault thermal magnetic release-8 Nos, CTs, ammeter with selector switch, voltmeterwith selector switch(Incomer)-01 Nos Bus bars: 250 A TPN aluminium Busbars suitable for 25kA for 1 Sec Outgoing Feeders :a) MCB TP 40 Amps 25 KA breaking capacity with short circuit adj overload and B/F thermal magnetic releaseb) Suitable enclose IE panel fabrication and bus bars for above MCB feeders. c) Angle iron base frame as reqd size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legsand made out of ISA 5050, 50 x 50 x 6 mm thick angle iron duly painted - 01 No.d) M & L for necessary grouting as reqd PCC 1:3:6 (40 mm graded aggregate) Type C2 for foundation of angle iron legs frame work complete - 01 job 36 Supply, installation, testing and commissioning of readymade 08 way TPN DB metal doorwith 200A rated busbar with following (CAT Part NoDBTPN008DDS of L& T or equivalent in Siemens/Legrand/C&S)Incomer: (a) MCB 4 Pole 60 Amps, 415 Volts breaking capacity 10kA 02 Nos (BB30630C of L &T)Outgoing feeders:(a) MCB TP 25 Amps, 415 Volts breaking capacity 10kA 04 Nos (BB30250C of L &T)(b)MCB SP 10 Amps, 230 Volts breaking capacity 10KA 04 Nos (BB10100C of L &T) 37 Supply, installation, testing and commissioning of outdoor line up of 11 KV RMU type compact panels, consisting of following :-11 KV 630 Amps 20KA for 3 sec. air/gas insulated RMU panel with 1 No incommingmanullay operated VCB and 02 Nos outgoing load break switches,CTs for protection as per detils given in specification complete in all respect inverse time over, current, short circuit & earth fault with instantaneous elements relay.Indication : ON, Off, Trip, R.Y.B. with facility for transformer buchholz relay trip with terminals for 230V AC supply aluminium Busbars 630 Amps, 11KV, TP busbars for 20 KA for 1 sec with PCC foundation all as per required & as per manufacturer instructions. complete all as specified and directed. 38 Supply, installation, testing and commissioning of 11KV 50/5 Amps ratio oil immersed vacume impragnated single phase current transformer with VA burden of 15 for class 0.5 class SP 10 with 25 KA short circuit rating for 1 second complete with all structure base and mounting arrangement as indicated and also as per specification and technical particulars. 39 Supply,Installation , testing and commissioning of outdoor line-up of 22 KV RMU type compact panels, consisting of : 22 KV 630A, 20KA for3 sec Air/Gas insulated RMU panel with 1 No Incomer & 2 Nos outgoing: 22 kV, 16 kA for 1 second, 630A HT VCB with 3 nos. resin cast 22000V/ sqrt. 3/ 110V/ sqrt. 3 withdraw-able PTs, HT and LT fuses ffor PTs, In comer 3 nos 50/1A & in outgoing 9 Nos. 20/1A CTs-core-1: class 0.5 CTs for metering, Core 2 : class 5 P10 for protection, inverse time over current, short circuit & each fault with intantenous elements relay, master trip, R.Y.B spring charge, trip circuit healthy. ON-OFF Push buttons illumination lamp, hooter, industrial socket with switch, space heater with thermostat, control MCB & control terminals etc complete all as specified and directed. 40 Laying only in trenches or fixing on wall or pole LT XLPE UG cable insulated screened PVC beded GI steel strip or wire armoured electric power cable (Heavy duty) with standard aluminium conductor 1100 volt grade of the follwing size including provision of necessyar lugs and glands as under : (Note- LT under ground cablementioned below at sl No (a) to (i) shall be issued under Sch Bfor laying/fixing ) 41 a) 300 sqmm 3.5 core 42 b) 240 Sqmm 3.5 core 43 c) 185 sqmm 3.5 core 44 d) 150 Sqmm 3.5 core 45 e) 120 Sqmm 3.5 Core 46 f) 50 Sqmm 3.5 Core 47 g) 35 Sqmm 3.5 core 48 h) 25 Sqmm 4 core 49 i)16 Sqmm 4 core 50 Supply and fixing and installation of fire extinguisher CO2 Map cap of 4.5 Kg as per IS 2878 Complete all as specified andas directed. 51 MS fire bucket 13 Ltr Cap of fire approved quality painted red filled with sand Complete all as specified andas directed. 52 Supply only hand gloves for safety,suitable for 22 KV grade. Complete all as specified andas directed. 53 Supply only hand gloves for safety,suitable for 11 KV grade. Complete all as specified andas directed. 54 MS padestal stand duly painted for suspending fire buckets 55 M&Lfor shock treatment chart in different languages (english, Hindi, Marathi) 56 Supply and placing of first aid box as per specification 57 Cable route marker made of galvanised iron supporting with GI angle for HT/LT cable root marking 58 M&L for Road cuttingby core cutting machine not less than 0.6 mtr wide and .45 mtr depthfor laying RCC and GI Pipe for the the HT/LT cable and making good surface with PCC 1:4:8 type D-2 using 40 mm graded stone aggergatecomplete all as specified and directed. 59 Supply and erect steel tubular poles swaged welded poles complete for two pole structure with MS base plate, MS pole cap, bolts nuts, and screws as per IS 2723 ( part II ) 1980 made out MS tyubing duly painted with metal primer and two coats of aluminium paint over exposed surface and Making 4 Nos of strips of 30 cm wide in alternate black and yellow colourup to 1.5 mtr hight, Writing pole number and voltage level encompassed by circle of suitable diausing two coats of synthetic enamel paint over a coat of red oxide zinc chrome primerbottomand one coat of red oxide and two coats of bituminous paint for embedded portion as specified type 410 SP - 31 of 9 mtrs long complete all as specified and as directed. ( Note- Excavation / earth work , PCC will be measured and paid separately ) 60 S&F FRP box,MCB SP 6 Amp-01 No and clamps made out of FI 32x6mm and GI nut bolts. Complete all as specified andas directed. make-syntex Model GSJB-3020 with 4 connectors or eqvt 61 S&Ftimer switch box fabricatedout of 16 SWG CRCA sheet with mounting arrangement duly powder coated consisting of the following :-a) Timmer astronomical-1, b) Power contactor 63 Amps make- -01 Noc) connector 100 Amps 230 Volts - 03 Nosd) MCB TPN 63 Amps 415 V - 01 Noe) Control fuse 2 Amps -01 NoComplete all as specified andas directed. 62 S&F pin type polymer/porcelain, vitreous, white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut 150 mm height, 150 mm dia for suitable for 22 KV working pressure. Complete all as specified andas directed. 63 S&F Disc type porcelain, vitreous, white, brown or green i nsulator includingone galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut 145 mm height, 255 mm dia ball and socket type Two-in-assembly for tension with tension clamps for conductor suitable for 22 KV working pressure. Complete all as specified andas directed. 64 Supply and lay rubber mat 2 mtr x 1 mtr,10mm thick 11 KV grade AC elect supply. Complete all as specified andas directed. 65 Supply and lay rubber mat 2mtr x 1 mtr,30mm thick 22 KV grade AC elect supply. Complete all as specified andas directed. 66 Supply and lay rubber mat 2mtr x 1 mtr, 19mm thick 11 KV grade AC elect supply. Complete all as specified andas directed. 67 Supply, jointing and testing Outdoor type cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm. Complete all as specified andas directed. 68 Supply, jointing and testing Outdoor type cable jointing kit for 22 KV (Earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm. Complete all as specified andas directed. 69 Supply, jointing and testing indoor typeCable jointing kit for 11 KV (Earthed)grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size ofsize 150 sqmm 70 M & L for discharge rod PVC coated suitable for 22KV. With PVC insulated copper conductor cable of size 7/20 of 10mtr long with crocodile clips at the end. Complete all as specified andas directed. 71 M & L for discharge rod PVC coated suitable for 11KV. With PVC insulated copper conductor cable of size 7/20 of 10mtr long with crocodile clips at the end. Complete all as specified andas directed. 72 Supply onlyEngine oil, multi grade premium Genuine oil 15W40 as per manufacturer recommendations in DG sets complete all as specified.Make : Indian oil/ Hindustan Petrolium/ Castrol/ BPCL. 73 Supply and applying for petrolium Jelly (01 Kg plastic sealed container) complete all as specified and as directed. Make : Indian oil/ Hindustan Petrolium/ Castrol/ BPCL. 74 Supply and fill for genuine coolant in 5 litres plastic sealed containerfor topping up in Radiator of DG set located at different locations complete all as specified and as directed. 75 Material and labour for battery leads of PVC insulated, multistranded, copper conductor of size 50 Sqmm of 1.25 metres long each duly fixed with brass clamps, copper lugs suitable for DG set batteries installed at different locations including removal of existing unserviceable one complete all as specified and as directed. 76 Material and labour for battery teriminal brass clamps including removal of existing unserviceable one compete all as specified and as directed. 77 Maintenance and servicing for Comprehensive C Check maintenance service for DG Set of capacity 160 KVAincluding dismantling, cleaning, filter & oil replacement, fuel system overhauling, radiator inspection, valve clearance adjustment, load testing, FIP Caliberation, checking and repair of radiator for leakage,and detailed service report submission as per OEM recommendation to DG setincluding replacement of defective and worn out minor filters gaskets, V- belts, Engine oil, rubber hoses, worm drive clamps, nuts, bolts and cleaning of alternator with vaccum cleaner and attending faults of AMF panels etc, tappet settings if required and greasing of bearings of engine and alternator, checking of batteries, applying petroleum jelly to battery terminals, adding distilled water checking the oil, coolent levels of capacity 100 KVA DG set installed at Southern Command Signal Centrecomplete all as directed by Engr- in- Charge.Note:- (i)Spares required for maintenance will be measured and paid seprately under relevant items. (ii) Servicing to be carried out as per manufacturer’s specifications/ instructions (iii)The work of maintenance shall be carried out through respective authorized dealer whose certificate shall be produced to Engineer - in - charge (iv) Proper record & test results of the same shall be maintained as directed (v)Work shall be carried out at site at different location Work to be carried out by OEM certified technician or approved equivalent. Service reports to be submitted post-maintenance 78 All as per item no. 11.066here-in-above but of capacity 100 KVA. 79 All as per item no. 11.066here-in-above but of capacity 30 KVA. 80 S & FLub oil filter set with O ring, (as perexisting sample) suitable for DG set of capacity 160 KVA. compete all as specified and as directed. 81 S & FLub oil filter set with O ring, (as perexisting sample) suitable for DG set of capacity 100 KVA. compete all as specified and as directed. 82 S & FLub oil filter set with O ring, (as perexisting sample) suitable for DG set of capacity 30 KVA compete all as specified and as directed. 83 S & F diesel filter element set with O ring,suitable forcapacities ofD. G . Set 160 KVA compete all as specified and as directed. 84 S & F diesel filter element set with O ring,suitable forcapacities ofD. G . Set 100 KVA compete all as specified and as directed. 85 S & F diesel filter element set with O ring,suitable forcapacities ofD. G . Set 30 KVA compete all as specified and as directed. 86 S & F air filter element suitable for capacities ofD. G . Set 160 KVAcompete all as specified and as directed. 87 S & F air filter element suitable for capacities ofD. G . Set 100 KVAcompete all as specified and as directed. 88 S & Fair filter element suitable for capacities ofD. G . Set 30 KVAcompete all as specified and as directed. 89 S & F by-pass filter element with O ring suitable for 160KVA DG set compete all as specified and as directed. 90 S & F by-pass filter element with O ring suitable for 100KVA DG set compete all as specified and as directed. 91 S & F by-pass filter element with O ring suitable for 30KVA DG set compete all as specified and as directed. 92 S & Ffan beltcomplete suitable for 100KVA DG set complete all as specified. Make : Fenner/ Dunlop. 93 S & F belt for battery charging alternator complete suitable for 100KVA DG set complete all as specified. Make : Fenner/ Dunlop. 94 S & F rubber hose pipe set for water circuit with clamps complete suitable for 100KVA DG set complete all as specified. 95 M & L for carrying out repairs to AMF panel of 100 KVA DG set at various installation inclduing study, tracing out circuit, testing, replacing all defective parts, rewinding existing power and control wiring with same cables including testing and commissioning complete all as specified and as directed. (Note: Spares like Volt meter, CT, power contactor required for repair will be measuredand paid seperately under relevant items. 96 S & Ffor digital type frequency meter 96 x 96 mm flush/ square pattern compete all as specified. Make: L&T/ AE or equivalent. 97 S & Ffor digital type Ammeter 0-200 /5 Amps 96 x 96 mm square flush pattern with selector switch compete all as specified. Make: L&T/ AE or equivalent 98 S & Ffor digital type Voltmeter 0-500 Volts 96 x 96 mm square flush pattern with selector switch compete all as specified. Make: L&T/ AE or equivalent. 99 S & F for LED indicator lamps R, Y, B with holder 15 mm screw type compete all as specified. Make: Rishab/ L&T/AE/ Legrand or equivalent 100 S & F for battery low maintenance lead acid of capacity 12 volts 135 AH with initial charging including removal of exsting unserviceable one and hand over to store yard compete all as specified and as directed. Make: Exide/ AMCO/ Amaron. 101 S & F for CT cast resin type of ratio 200/5 Amps of suitable VA burden compete all as specified. Make: AE/ L&T/ Nutech/ Amol 102 Supply and fix for lead acid battery 12 Volts 180 AH with initial charging and having indicators to know the status of level of electrolyte complete all as specified and as directedMake- Exide/Amaron. 103 Supply &filling up of transformer oil conforming to IS -335 of 1993 as in topping up / replacementup to desired level of transformer oil capacity and Oil circuit brekar complete all as specified and as directed. [Note: Dielectric strength of oil should not be less than 42 KV/cm complete all as specified and directed.] 104 Supply only breather assembly as per existing size, shape and specification complete for capacity 315 KVA , 11/0.433 Voltstransformers including fresh blue silica gel 105 Painting of transformer after cleaning the body surface of transformer by rubbing with emery Paper to remove oil stains, dust etc and applying one coat of snthetic enamel paintby spray paint incl writing SM No/MES No , capacity of transformer of 315KVA capacity all as directed by Engr-in-Charge 106 Supply and fix for switch air break gang operated HT 11 KV Volt grade out door type, triple poleof capacity 200 amps rating mounted on Polymer based 09 insulator with expulsion fuse set single pole drop out type including Expulsion fuse carriers and fuse element Upto 25 Amp and fitted on steel frame horizontally mechanicallyoperated mechanism from ground level consisting of operating rod of 25 mm bore Heavy grade GI pipe of suitable length worked from ground level and with locking arrangements incl pad locks with key flat iron clamp 50 mm x 6 mm including taking down old unseviceable one complete all as specified and directed. (Universal/Pactil) 107 Supplying, installing, fixing, connecting and testing of polymer based Drop-out fuse set (set of 3 nos), mounted on insulatorswith steel frame 200 Amps capacity, siutable for 11KV, HT system,out door type, including Expulsion fuse carriers and fuse element Upto 25 Amp, including taking down old unserviceable one complete all as specified and directed. Make : Universal/National or its equivalant.Note for Item No 11.094 & 11.095 : The work to be carried out in existing structure. Hence continues shut down will not be available. According to the availabity of shut down timing the contractor shall manage the work in quoated rate only. 108 M&L for Painting of HTpoles including cross arms complete with synthetic enamel paint including filling cavities with filler one coat after cleaning all dust/rust including writing the pole No. and all as directed by Engr-in-Charge 109 M & L for Servicing of Molded Case Circuit Breakers (MCCBs)/ACB in existing panelsincluding cleaning, tightening of connections, checking of mechanical operation, insulation resistance testing, functional testing, lubrication of moving parts, and recording of test results. All tools, materials, labor, and consumables to be included for following capacity:- 110 630 Amps ACB 4 pole,415 volt manual drawout type with micro processor release 111 3 Pole 350A MCCB, 36 kA 112 3 Pole 250A MCCB, 36 kA 113 3 Pole 160A MCCB, 36 kA 114 3 Pole 125A MCCB, 36 kA 115 3 Pole 100A MCCB, 36 kA 116 3 Pole 63A MCCB, 36 kA 117 3 Pole 32A MCCB, 16 kA 118 S & F in repairs ACB 4 Pole, current rating 630 Amp, adjustable over load and short circuit with Micro processor release setting , breaking capacity 36 kA at 415V, 50Hz, of(Make : L & T Cat No CM96111OOOOX1 or equivalent in Legrand / Schenedier) incl necessary spreaders / cable lugs / nut, bolt and washers if required all as directed. 119 S & F for 4 pole MCCB400 A, having breaking capacity 36 kA (Make : L & Tor equivalent in Legrand / Schenedier) complete all as specified and as directed. 120 S & F for4 pole MCCB 250 A, having breaking capacity 36 kA (Make : L & Tor equivalent in Legrand / Schenedier) complete all as specified and as directed. 121 S & F for4 pole MCCB 200 A, having breaking capacity 36 kA (Make : L & Tor equivalent in Legrand / Schenedier) complete all as specified and as directed. 122 S & F for 4 pole MCCB 160 A, having breaking capacity 36 kA (Make : L & Tor equivalent in Legrand/ Schenedier)complete all as specified and as directed. 123 S & F for 4 pole MCCB 100 /125 A, having breaking capacity 36 kA (Make :L & Tor equivalent in Legrand / Schenedier) complete all as specified and as directed. 124 S & F for 4 pole MCCB 63 A, having breaking capacity 10 kA, (Make : L & Tor equivalent in Legrand / Scheneider) complete all as specified and as directed. 125 M&Lfor switch air break gang operated triple pole mechanically operated mounted on HT insulators horizontal type and MS galvanized steel frame with operating mechnizing worked from ground level including operating rod of size 32 mm dia / 25 mm dia as reqd GI medium grade for current rating upto 200 Amps 22000 volts complete with locking arrangement ,ms clamps ,bolts ,nuts and washers etc.including two coat of aluminium paint over a coat of red oxide primer on ms work complete all as specified complete all as specified and as directed. 126 S&F for drop out fuse assy single pole 22KV , 25 Amps rating complete expulsion fuse element mounted on four /two pole structures complete all as specified and as directed.(Necessaty Nut, bolt and washers should be included in above quoted rate) 127 S&F fordrop out fuse assy single pole 11KV , 25 Amps rating complete expulsion fuse element mounted on four / two pole structuresincluding dismanteling old existing UNSV all as specified and as directed.(Necessaty Nut, bolt and washers should be included in above quoted rate) 128 S&F for pin type insulator, HT Polymer/porcelain vitreous white, brown or green of size 150 mm high and 150 mm dia, ISI marked including one galvanised steel spindle, two galvanised iron washers and one galvanised iron nut suitable for 22000 volts including dismantling insulator any type / any sizecomplete all as specified and as directed. 129 S&F for insulator disc type single disc assembly, ISI marked working pressure 22000 volts, porcelain vitreous white, brown, or green size 145 mm high and 255 mm dia ball and socket with tension clamp to suit the size of conductor (ACSR)including dismantling insulator any type / any size complete all as specified and directed. 130 M&L for aluminium strip 25 x 4 mm of required lengthwith color sleeves for jumpering purpose in 11 /22 KV DP/FPincluding taking down existing aluminium conductor etc complete all as per the direction of Engineer-in-charge. 131 S & Ffor gasket set of 22/11 KV 100 KVA to 400 KVA transformer complete all as specified and directed. 132 S& F for silicagel breather complete all as specified and directed. 133 M&L for Testing of exisiting earthing resistance with suitable digital Earth tester complete all as specified and directed 134 S&Fepoxy based insulator with screw, nuts and bolts fixed on OH reservior roof top and on shaft surfaces not more than 2.00 m apart from fixing aluminium or GI strip complete with fixing arragnment complete all as specified and directed. 135 Supply, laying,testing and commissioning or passing through pipe,XLPE insulated, screened, PVC bedded, galvanisedsteel striporwire armoured,electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area of size 3 core 150 Sqmm 136 Laying in trenches and testing cable XLPE insulated screen PVC bedded galvanized steel strip or wire armoured, electric power cable heavy duty with stranded aluminium conductor, 22000 volts grade of size 3 core X 185 sq mm suitable for earthed system etc complete.(Note-HTcablewill be issued under Sch B free for fixing/laying). 137 Supply, installation and testing complete electronic digital type water level indicator devicesuitable for operating at 230V +/- 10%, 50 Hz sysytem having 150mm size digital display and alarm at low/high level of OHT / sump.The complete unit fitted in MS sheet base in two boxes, one box to be installes at sump/OHR and second at pump house bothunit to be connected with flrxible copper cable of .5 sqmm 8 pair and length from sensor to pump house building or OH reservoirs of 21 mtr and 15 mtr staging,All enclosed in sheet metal enclosures of 02mm thick with hinged door and locking arrangement and support GI wire/PVC pipe etc properly laid or fixed on wall / surface all as directed by Eingr-in-charge.Make- SECO type DDS-6 or equivalent model in Schneider/ Havels/ L&T. 138 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 40 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 139 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 50 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 140 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 75 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 141 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 90 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 142 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 110 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 143 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 120 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 144 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 160 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 145 MISC ITEMS OFEXTERNAL WATER SUPPLY 146 Laying and testing ductile iron pipe with internal cement mortor lining and external zink pipes confirming to IS:8329-2000 with class of pipe K-7 of size 150 mm including rubber tyton joints. Complete all as specified andas directed.Note - DI pipe 150mm bore will be issued under Sch B for fixing only. (Rates of DI fitting required for sch B items will be included in the quoted rates) 147 Laying and testingductile iron pipe with internal cement mortor lining and external zink pipes confirming to IS:8329-2000 with class of pipe K-7 of size 200 mm including rubber tyton joints. Complete all as specified andas directed.Note - DI pipe 200mm bore will be issued under Sch B for fixing only.(Rates of DI fitting required for sch B items will be included in the quoted rates) 148 Laying and testingductile iron pipe with internal cement mortor lining and external zink pipes confirming to IS:8329-2000 with class of pipe K-7 of size 100 mm including rubber tyton joints. Complete all as specified andas directed.Note - DI pipe 100mm bore will be issued under Sch B for fixing only.(Rates of DI fitting required for sch B items will be included in the quoted rates) 149 Supply, fix and testing dual type non return valve of 100 mm bore, cast iron body with both ends flanged,heavy duty (ISI marked) by pass arrangement ,including jointing material, bolts, nuts,rubber packing etc complete confirming to relevent IS. Complete all as specified andas directed. 150 Supply, fix andtesting gun metal dual type non return valve of25mm bore,iron body with both ends flanged,heavy duty (ISI marked) by pass arrangement ,including jointing material, bolts, nuts,rubber packing etc complete confirming to relevent ISComplete all as specified andas directed. 151 M& L for DI fittings & specials such as collar, bends (any type radius, any angle, double end socketted or double flanged or spigot & socket, tail pieces (all socketed or all flanged with an equal & other end taperingbellmouth or flanged plates, connecting pieces straight (both end flanged or socketed of socket & flanged & spigot ends or bellmouth tailpieces ( one end flanged & other end spigot or socket or tatering as bell mouth or flanged ) caps blank flanges heavy duty suitable for run lead joints ofsize from 80 to 200 mm bore. Complete all as specified andas directed. 152 Supply, fix and testing GM gate/globe valves heavy duty conforming to IS 778 with iron wheel head screwed both ends suitable forfollowing sizes ofbore:-Complete all as specified andas directed. 153 25 mm bore 154 40 mm bore 155 50mm bore 156 80 mm bore 157 Install,testingand commissioning of LT distribution outdoor typepanel board compartmentalized fabricated, factory made cubical type dust and vermin proof indoor type power coated 415 volts 3 phase 4 wire 50 HZ front openable with locking arrangement made out of CRCA sheet of 3.15 mm thick with MS angle iron of size 50x50x6 mmto be mounted on floor / wall suitable to accommodate common bus bar and the following accessories:(a) MCCB TPN 100 Amp 25 KA 415 Volt thermal adjustable- 1 No. (b) Copper bus bar 400 Amps. 4 runs duly coloured PVC sleeve (c) Fully automatic star delta starter suitable for 7.5 HP pump set 440 V Model MK-1 Make L and T with electric connection - 02 No. (d) MCCB TP 10 KA 63 Amp - 02 N os (e) MCB DP 32 Amps - 02 Amps(f) Ammete 0-200 amps with CT & selector switch - 01 No (g) Voltmeter 0-500 V with selector switch - 01 No(h) lndiating lamp - LED type RYB ) Complete all as specified andas directed.( Note- LT panel with all fitment accessories shall be issued under Sch B free for fixing ) 158 Install test and commissioning of LT distribution panel board compartmentalized fabricated, factory made cubical type dust and vermin proof indoor type power coated 415 volts 3 phase 4 Wire 50 HZ front openable with locking arrangement made out of CRCA sheet of 2 mm thick with MS angle iron of size 50x50x6 mm to be mounted on floor / wall suitable to accommodate common bus bar and the following accessories :- (a) MCCB TPN 63 Amp 25 KV 415 Volt - 1 No.(b) Copper bus bar 400 amp - 4 runs duly coloured PVC sleeve (c) DOL starter suitable for 3.0 HP pump set 440 V Model MK-1 make L&T with electric connection :- 2 No. (d) MCCB TP 40 Amp 10 KA 415 Volt-2 No (e) MCB DP32 Amp - 2 No.(f) Ammeter 0-100 Amp with CT and selector switches – 1 No(g) voltmeter 0-500 V with selector switch 01 No (h) Indicating lamp LED type RYB – 01 Set.Complete all as specified andas directed.( Note- LT panel with all fitment accessories shall be issued under Sch B free for fixing ) 159 Install, Test, Commissioning of open well submersible pump set 80x80mm for pumping clear water at ambient temperature from UG sump for delivering 25 m3/hours at a total head of 40 mtr complete with suitable electric motor 7.5 HP, 3 phase, 415 volts, 50 HZ with dry run protector and delivering with GI medium grade pipe of 80 mm dia with flanged bend brought outside the sump GL upto 1.0 mtr and including having GI chain/rubber insulated rope of suitable length to lift the pump set with necessary submersible cable connection.Complete all as specified andas directed. ( Note- submersible pump setshall be issued under Sch B free for fixing ) 160 Install, Test, commissioning of open well submersible pump set 25x25 mm for pumping clear water at ambient temperature from UG sump for delivering 165 LPM at a total head of 25 mtr complete with suitable electric motor 3.0 HP, 3 phase, 415 volts, 50 HZ with dry run protector and delivering with GI medium grade pipe of 50 mmdia with flanged bend brought outside the sump GL upto 1.0 mtr and including having GI chain/rubber insulated rope of suitable length to lift the pump set with necessary submersible cable connection .Complete all as specified andas directed.( Note- submersible pump set shall be issued under Sch B free for fixing ) 161 Installation, testing and commissioning of 750 LPM capacity head105 M end suction type centrifugal pump set for water supply assembled and tested for rated efficiency complete with energy efficient motor conforming to IS-12615 common base frame, coupling guard and mechanical seal suitable for operation on 415 ± 10% 50 Hz AC supply slow speed up to 1500 Rpm multistage pump with Bronz impeller includsive of suitable star delta starter inclding cable from starter to motor drawn through flexible metallic conduit pipe starter and suitable PCC foundation etc complete as per manufacturers recommendation. Complete all as specified andas directed. ( Note- Centrifugal pump set shall be issued under Sch B free for fixing ) 162 Installation, testingend suction type centrifugal pump set for water supply assembled and tested for rated efficiency complete with energy efficient motor conforming to IS-12615 common base frame, coupling guard and mechanical seal suitable for operation on 415 Volt + 10%, 50Hz AC supply slow speed up to 1500 Rpm multistage pump with Bronz impeller inclusive of suitable star delta starter inlcuding cable from starter to motor drawn through flexible metallic conduit pipe following capacity inclusive of starter and PCC suitable foundation as per manufacturers recommendations. Capacity 1460 LPM, Head-100M. Complete all as specified andas directed.( Note- Centrifugal pump set shall be issued under Sch B free for fixing ) 163 Supply,install,testing & commissioning of end suction type centrifugal pump set, multistage,bronze impellor,water supply, assembled and tested for rated efficiancy complete with energy efficient motor conforming to IS 12615 common base frame,coupling guard and mechanical seal suitable for operation on 415 volts+/- 10%, 50HZ AC supply of capacity 1500 RPM, 700 LPM, head 70mtr inclusive of PCC foundation ,suction & discharge of pipes as per manufactures instruction.Complete all as specified andas directed.Note:- Cost of suction and discharge pipes upto 7.50 RM long each shall be deemed to be included in the rate quoted. 164 Supply installation,commissioning and testing ofDOSING SYSTEM ( MODEL: ADS-I of ALTOCH) consisting of 40 liter - 100 liter PE/FRP LID & leval gauge along with agitator with shaft and blade in plastic. mounted on tank Complete all as specified andas directed.. (Make : ALTOCH or Equvivalent as approved by Accepting officer) 165 S&F Cast iron body foot valve of size 150 mm bore flanged as per IS 4038 , including nuts, bolts, washers and rubber gaskets, complete all as specified & as directed. 166 Supply installation,commissioning and testing ofdosing pump model 96NGQ51 of Decrain,high presser single head gear motored adjustable dosing pump of following specification:-.(a) Adjustable high presser -0 to 100 PSI (b) Power-230v, 50HZ (c) RPM-44(d) HP 1/10 fractional(e) Out put -2 U.S GPD to 40 USGPDComplete all as specified andas directed.(Make : Decrainor Equvivalent as approved by Accepting officer) 167 S & F Cast iron air release valves with two air outlets of 50mm bore and fixing of cast iron pipe including necessary fittings. Complete all as specified andas directed. 168 Supply,Laying and jointing & testing DI pipe with socket & spigot ends, class K 7 with cement morter lining in side the pipe and zinc coatedout side asper IS 18329/2000 in standard length suitable for push onwith rubber gasket joints(tyton joints) laidintrenchesof size 150 mm bore. Complete all as specified andas directed. 169 Supply, laying, jointing and testing Ductile iron pipes with spigot and socket ends centrifugally cast, Class K-9 conforming to IS-8329of following sizes, in any length, laid in trenches/ pipe supports etc, pressure testing after laying complete a per IS-12288 including styrene butadiene rubber gasket joints, complete all as specified and as directed.NOTE: Tyton joints required are deemed to be included in the unit rate quoted. 170 100 mm bore pipe 171 200 mm bore pipe 172 M&L testing & Commissioning of LT pannel frame CPRI approved, outdoor type,factory made fabircated to CRCA sheet of with min 1.6mm mm thickness, double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, aluminium bus bar chember (enclosed) with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold,nuts and washer and making complete connection in all respects as diected by engr-in-charge comprising of foillowing parts.INCOMER :-(a)MCCB 200 Amp, FP, Thermal Magnetic release, 35 KA- 01 No as IncomerOUTGOING :-(a)MCCB 160 Amp, TPN,Thermal Magnetic release, 25 KA, 415 Volts - 02 Nos(b)MCB SPN 32 Amps - 01 Nos(c)Indicating lamps (Set of 03 Nos) - 01 Set.(d)Star Delta starter 02 Nos with overload relay ragne 60 Amp- 2 Nos (e) Aluminium bus bar chamber (4 Strips) 3 phase 415 volts 200 Amps fixed on insulatorsall as required - 01 Set 173 (f)Digital voltmeter 0-500 volts with selector switch - 01 Set(g)Digital ammeter with CTs & selector switch 0-100 A cap- 03 Set(h) Panel Wiring with suitable size PVC insulated PVC sheathed 1100 volts grade with copper conductor multi-stranded cable with lugs on both ends of cable.(i) Front operated on load change over switch 100 amps.-01 No .Make : L&T/C&S/ABB/Havells(j) Star Delta starter fully automatic, 3 phase, 415 volts, 50 Hzheavy duty with overload relay ragne 60 Amp having protection against single phase, over load and phase reversal protection. - 02 NosMake of starter BCH/L&T/ Seimen/C&S/Havellscomplete all as specified and directed. 174 M&L testing & Commissioning of LT pannel frame CPRI approved, outdoor type,factory made fabircated to CRCA sheet of with min 1.6mm mm thickness, double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, aluminium bus bar chember (enclosed) with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold,nuts and washer and making complete connection in all respects as diected by engr-in-charge comprising of foillowing parts.INCOMER :-(a)MCCB 200 Amp, FP, Thermal Magnetic release, 35 KA- 01 No as IncomerOUTGOING :-(a)MCCB 160 Amp, TPN,Thermal Magnetic release, 25 KA, 415 Volts - 02 Nos(b)MCB SPN 32 Amps - 01 Nos(c)Indicating lamps (Set of 03 Nos) - 01 Set.(d)Star Delta starter 02 Nos with overload relay ragne39 Amp- 2 Nos (e) Aluminium bus bar chamber (4 Strips) 3 phase 415 volts 200 Amps fixed on insulatorsall as required - 01 Set(f)Digital voltmeter 0-500 volts with selector switch - 01 Set(g)Digital ammeter with CTs & selector switch 0-100 A cap- 03 Set 175 (h) Panel Wiring with suitable size PVC insulated PVC sheathed 1100 volts grade with copper conductor multi-stranded cable with lugs on both ends of cable.(i) Front operated on load change over switch 100 amps.-01 No .Make : L&T/C&S/ABB/Havells(j) Star Delta starter fully automatic, 3 phase, 415 volts, 50 Hzheavy duty with overload relay ragne 60 Amp having protection against single phase, over load and phase reversal protection. - 02 NosMake of starter BCH/L&T/ Seimen/C&S/Havellscomplete all as specified and directed. 176 MISC ITEMS B/RWORKS 177 S&F factory made Steel fibre reinforced manhole frame and cover 100mm thick of size 1.20m x 0.60m complete all as specified and directed. 178 M & L for recharging of normal earth pits by excavating the earth at a radius of 600mm from the centre from the earth pit and at a depth of 900mm after removing the earth chambers and accessories carefully and keeping aside for reuse including adding and spreading chemicals as given below in 75mm layers each as ground level and watering, refixing the earth chambers and accessories after allowing the soil to settle down complete all as specified and directed by Engr-in charge.(a) Charcoal 10 kg. (b) Salt 10KgNote :- Excavation , refillingis included in quoated rate 179 Supply and fix for repairs earth chambers by demolishing unserviceable earth chambers and fixing new chambers ofPCC 1:3:6 type C1bed and chamber RCC 1:2:4 type B1of size (600X600X200)mm and thickness 120 mm andand CI cover 10mm thick hinged to CIframe duly groted with PCC, complete all as specified and directed. 180 Construction of valve chamber with PCC solid block masonry grade C-5, 200mm thick having 150mm thick hard core and PCC (1:4:8) type D-2 (using 40mm graded stone aggregate in foundation, including excavation & earth work in any type of soil, internal & external plaster to walls in cement morter 1:6, 15mm thick complete all asspecified and shownon drg No CEPZ/93/TD/20M Sht No 1/1 of following internal dimension:- 181 0.60mtr x 0.60mtr x 0.60mtr 182 1mtr x1mtr x1mtr 183 1.2mtr x1.2mtr x1.2mtr 184 Cutting the existing water line 300 mm dia for inserting Tee Reducer bend, coller etc complete ( Note : CI specials, lead joints excavation and earth work shall be measured and paid separately under relevant item of this schedule ) 185 Moblization of necessary equipment & manpower at site of work to carry out plate load test for determination of K Value (Modules of subgrade reaction) of Soil in the field in accordance to IS 9214-1979, complete in all respect, as specified & directed with & including following operations.(a) Digging out Pit of desired size & depth.(b) Placing & arranging Poclain, as per requirement & recording the settlement data with 03 Nos of dial Gauge in Horizontal Plain Placed at 120 degree, using Hydraulic Jack with proving ring & dial gauze of least count 0.002 mm & submission of report in sixtulicate determining modulus of subgrade reaction K Value.
Contract Date: Feb 06, 2026 Contract Value : 8.36 Crore
Statutory Bodies & Commissions/Committees No of Bidders 6
Maharashtra View Result →
50.
Defence #9353987 Technical Bid
Tender For Provision Of Work Services For Solar Power Plant At Af Stn Adampur; 1 SCHEDULE `A PART - I (Building Works) is not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only. 2 Construction of SUB STATION BLDGcomplete all as specified and shown on drawings. 3 NOTE: Schedule ‘A’ Part IIto X under Ser No. 2.01to 2.10 are Prepriced by MES. 4 Lump sum price worked out by the Contractor for “SITE CLEARANCE, EXCAVATION AND EARTH WORK” as listed in Schedule ‘A’Part II 5 Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION as listed in Schedule ‘A’Part III 6 Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY as listed in Schedule ‘A’Part IV 7 Lump sum price worked out by the Contractor for “SOLAR POWER PLANT” as listed in Schedule ‘A’Part V 8 Lump sum price worked out by the Contractor for “ROAD/PATH/CULVERT” as listed in Schedule ‘A’Part VI 9 Lump sum price worked out by the Contractor for“EXTERNAL WATER SUPPLY ” as listed in Schedule ‘A’Part VII 10 Lump sum price worked out by the Contractor for“EXTERNAL ELECTRIFICATION ” as listed in Schedule ‘A’Part VIII 11 Lump sum price worked out by the Contractor for“SEWAGE DISPOSAL ” as listed in Schedule ‘A’PartI IX 12 Lump sum price worked out by the Contractor for“AREA DRAINAGE” as listed in Schedule ‘A’Part X 13 Lump sum price worked out by the Contractor for“FENCING AND GATE” as listed in Schedule ‘A’Part XI 14 SCHEDULE `A PART - XII MISC ITEMSis not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only. 15 INTERNAL ELECTRIFICATION 16 S&F LED light fitting 1 x 10 Watt, 220V, AC,box type with driver, holder incl making connection with three core flexible copper conductor cable 0.5 sqmm from ceiling rose complete all as specified and directed. 17 S&F LED security light fitting 20 watt, input 110 to 220 voltsas per IP 65 luminaries comprising of rectangular shape, high pressure die cast aluminium housing, with weather proof gaskets for lamp and driver compartment with GI pipe 25 mm dia light grade bend to shape including necessary fixing arrangement complete all as specified and directed. 18 SOLAR POWER PLANT 19 Design, supply, erecting, installation, testing & commisssioning of ON Grid connected, ground mounted solar PV Plant of 737 KWp capacity at standard condition (irradience temp etc) at AF Stn Adampur (Longitude 75° 44 20 E, Lattitude 31° 26 14 N & elevation 244.54 mtr). The ripple content shall not exceed 3% on DC and harmonics shall not be more than 3%, Micro processor based directional & revese power flow protection shall be provided to ensure isolation of SPV from Grid at the time of fault including all connected equipments required for their smooth functioning comprising of the following major componenets all as specified:- 20 Supply, erecting, installation, testing & commissioning of framed dual glass bifacial Solar modules each consist of 144 cells (12x6+12x6), size of module 2278mm (L) x 1134mm (W) x 33mm (T) or as approved, M10 TOPCon N type mono bifacial solar cells not less than 585 Wpeach, front glass 2mm low iron printed semi tempered glass, back glass 2mm low iron printed semi tempered glass, PID free & UV resistant encapsulate, IP68 weatherproof PPO junction box, compatible with IP68 rated MC4 connector alogwith 1400mm DC, Copper cable of 4sqmm size, anodized aluminium framehaving efficieny more than 22.5% at standard test condition. These panels shall be suitably fixed on Module mounting structure. The electrical Data of panel at standard test condition (STC) 1000W/m² irradiance, air mass 1.5 & 25°C cell temperature shall be as under:-(i) DC peak power (Pmax) - not less than 585 Wp. (ii) DC peak voltage (Vmp) - 44.15V (Approximate). (iii) DC peak current (Imp) - 13.25A (Approximate), (iv) Short circuit Current - 13.99A (Approximate). (v) Open circuit Voltage - 52.70V (Approximate). (vi) Module efficiency - 22.65% (Approximate). (vii) Operating temp range (-) 40°C to 85°C. (viii) Series fuse rating = 30A (Approximate). (ix) Junction box = IP68, weatherproof PPO. (x) IP68 rated MC4 connector compatiable. (xi) Anodised aluminium frame. (xii) front glass 2mm low iron printed semi tempered glass. (xiii) back glass 2mm low iron printed semi tempered glass, PID free & UV resistant encapsulate. (xiv) Sustain heavy snow upto 5400 Pa. (xv) Sustain wind loads upto 2400 Pa. 21 Note :-(a) The PV modules must be tested and approved by one of the IEC authorised test centers. In addn a PV module qualifacation test certificate as per IEC standard, issued by ETDC Bangalore or Solar Energy Centre will also be valid. (b) Warranty on output and life of structure shall be as under :-(i) Output wattage of PV modules shall not be less than 90% at the end of 10 years and 80% at the end of 25 years.(ii) The mechanical structure, electrical works and overall workmanship of the grid solar power plant must be warranted for a minimum of 5 years.(iii) Grid solar PV power plant must install necessary equipment to measure solar radiation, ambient temperature, solar energy meter 11 KV to measure grid solar power generation, wind speed and other weather parameters contnuously. Simullataneuosly measurement of the generation of DC power as well as AC power from the plant must be done. 22 (c) Each module shall have RFID tag bearing the following details. RFID reader shall be provided by contractor :-(i) Name of manufacturer of PV module (Should be made in INDIA). (ii) Name of manufacturer of solar cell (Should be made in INDIA). (iii) Month and year of manufacture (Separately for cell & module). (iv) Country of origin separetly for cell & module (Made in INDIA only). (v) Peak Wattage, Im, Vm and fill factor of the module. (vi) Date of year of obtaining IEC PV module, qualification, certificate. (vii) Unique serial no and model no. of Module. (viii) I-V curve of module. (ix) Name of the test Lab issuing IEC certificate. (x) Every module should have PID test report as per latest prevalling norms of MNRE & will be submitted to the GE. (xi) Solar cells & Modules shall meet DCR norms. 23 (d) Provision of earthing and earth strip/cables etc. for earth for solar PV module/Array as per latest IS/MNRE norms to be providied it will be measured and paid seperatly. (e) PV module shall confirm to IEC:61215, IEC: 61730, UL:61730-1 & 2 for construction, testing and safety qualifacation and latest minimum technical specifications. The module shall be manufactured in 2024 or subsquent year. Product warranty shall be for at least 12 years and performance warranty shall be at least 25 years. 24 (f) The contractor will submit the complete design of ON Grid connected Solar PV Plant alongwith complete design details, drawings, calculation sheet and connected documents within one month of acceptance of tender and before procurement of the material. The same shall be submitted to GE after vetting from IITs/NISE for approval of accepting officer. (i) The complete design will submitted to Accepting Officer through CWE for final approval before placing order of the materials to be used in Solar PV Plant. (ii) The test report of modules as per national and international standards and technical data shall be submitted by contractor to GE for approval of accepting officer. (iii) Minimum 0.5% of PV Module shall be tested for all electrical parameters incl efficieny & safety measure by the rep of AO at OEM factory premises before dispatch as per technical data sheet of the manufacturer. (iv) Contractor will submit 2% amount of total quoted amount against item Sl No 4.04 (PV Module) as performance security of PV Module in the form of FDR or BGR in favour of the Accepting Officer which will be refurned to the contractor on successful performance copletion of 25 years of PV Module.(v) Contractor will submit gurantee for at least 25 years performance of PV Module as per CA provision and in case of any manufacturing fault of any PV Module during the performance warranty of 25 years the same shall be replaced by the contractor without any extra cost. (vi) All the modules shall be of same make. (vii) Rates of testing at Factory premises of OEM or MNRE approved Lab are deemed to be included in the quoted rates.(g) Make : MNRE approved and as per list of makes mentioned in Appx D of the tender documents. 25 (viii) The solar power plant shall be got tested/ inspected by third party i.e. NISE or any other Govt approved lab as decided by Accepting officer. Cost of testing and all other arrangement for this shall be made by the contractor without any extra cost.Third party inspection/ testing shall be carried out after execution of complete work and all departmental testing. (ix) Acceptance/ Final test from rep of Accepting Officer shall be carried out after physical completion of solar power plant work.All arragement for this shall be made by the contractor without any extra cost. (x) The following tests shall be carried out: (i) Performance ratio test (ii) CUF (iii) Efficiency test (iv) Irradiance test (xi) All drawings and design duly supported with detail calculation and property of the equipment shall be submitted by the contractor within two months from the date of issue of work order for approval of the Accepting officer. 26 Design, supply, installation, testing & commissioning String PV Inverter of capacity not less than 250 KW. Input DC & output AC specification of the inverter shall be as under :-Input DC. Max input DC voltage not less than-1500V, rated input voltage not less than 1080V, start up voltage 550V, minimum MPPT voltage range 180-1500V DC, MPPT voltage range at full load 800-1300V DC, minimum number of string input 24, minimum number of MPP trackers-12, string per MPPT- 2 Nos, max input current per MPPT shall not be less than 30A, max short circuit current per MPPT shall not be less than 50A. 27 Output AC.Minimum AC output power 250 KVA@30°C, 235KVA @40°C, 220 KVA @ 50°C, max output current not less than 184A, Nominal 3 phase voltage- 800V, minimum Grid voltage range 640-920V, Frequency- 50/60Hz, Grid frequency range - 45~55Hz, Active power adjustment range- 0-100%, THDi- <3%, power factor 0.8 leading-0.8 lagging, 3 phase.Performance.Max efficiency - not less than 99.01%, European weighted efficiency - not less than 98.8%, outdoor string solar power grid tie inverter suitable to convert DC power of solar PV module/array to AC for further feeding to grid & conforming to IEC-61683 for efficiency, IEC-62109 (1&2) or equivalent for safety & IEC-62093 for reliabilty. The inverter shall be self-communicated with pulse width modulation (PWM) technology and shall be capable to synchronize with grid maximum in 1 minute. Maximum Power point tracker (MPPT) conforming to IEC-62093 shall be intergrated in the inverter to maximize energy drawn from the solar PV array. 28 The inverter shall have following protections:- (i) DC reverse polarity protection. (ii) Anti Islanding protection. (iii) Leakage current protection. (iv) Ground fault monitoring. (v) PV array string fault monitoring. (vi) Zero voltage ride through. (vii) DC switch. (viii) Anti PID protection. (ix) AFCI protection (Arc Fault Circuit Interrupter). (x) Over voltage. (xi) Under voltage. (xii) Overload. (xiii) Shorcircuit. (xiv) Earth fault. (xv) Under frequency and over frequency.Protection class/Overvoltage category- I/III. Input/output SPD- PV type-II & AC type-II standard. Electromagnetic compatibility (EMC) as per EN-61000-6-2&4. Safety standard as per IEC62109-1/2, IEC62116, IEC61727, IEC61683, IEC60068(1,214,30). Communication- RS485, USB, Bluetooth, Wi-fi, GPRS, PLC.Inverter shall monitor the following:-(i) DC input voltage (ii) DC input current (iii) DC ripple (iv) DC input power (v) AC output (vi) AC output current (vii) AC output power (viii) AC output frequency (ix) AC output power factor (x) Synchronization status (xi) Grid voltage (xii) Grid frequency (xiii) Grid (ii) Ground fault (iii) PV string fault montioning inverter shall have arrangement for adjusting DC input current & shall trip against sustainable fault down stream and shall not restart till fault is rectified. 29 General specification:- (i) Ambient temperature range - (-) 30°C to (+) 60°C. (ii) Self consumtion power at night - < 2W, Topology- Transformerless. (iii) Degree of protection - IP66. (iv) Allowable relative humidity 0-100%, max operating altitude - not less than 4000M, (v) Noise - <60Db. (vi)Cooling - Smart forced air cooling. (vii) Display - LCD & Bluetooth+App.Rate for PCC foundation including required concreting and steel fixing as instruction and directed by engineer-in-charge are deemed to be included in quoted rates.Isolation method tranformer less smart forced cooling LED display, Rs 485/PLC communication, smart IV Curve Diagnosis, Type II SPD for both DC & AC with 5 years guarantee. Make: HITACHI/Delta/Sungrow.Note:- (i) Contractor shall submit parameter sheet of inverter duly recommended by GE & CWE for approval of AO before placing order to the company. (ii) All the inverter shall be of the same make & model. 30 MC4 CONNECTORSSupply, installation, testing & commissioning of solar MC4 connectors (Male and female both) having copper pin with tin plating with 1500 V DC & not less than 30 Amp. Current suitable for 4/6 sqmm cable, degree of protection IP-68, contact resistance < 2 mili ohm, insulation resistance >500 Mega ohm, insulation material PPO, protection class-II, application class A, standard EN 50521: 2008 TUV certified and shall also meet the requirement of IEC:61984 complete all as specified and directed. Make: Indygreen/Elmax/synergy/Eteilyte Technologies India Pvt Ltd . 31 Modules Mounting Structure (MMS) Design, supply and erect Module mounting structure made up of MS Hot dip Galvanised (80 Micron) as per IS 4759, GI frame Structure to hold approved solar panels mounting with all accessories.Fixing arrangements for fixing the PV solar modules & to withstand minimum horizontal wind speed of 170 km/ hr as per IS. It shall conforming to latest revesion of IS 2062 having Grade of 250 MPA. The MMS design shall be submitted by the contractor and shall be approved by AO. The solar panel shall be fixed at a tilt angle of 31° or as per designed SPV Plant. Note : The design should be similar as per drawing attached. 32 Mounting Structure shall have following specification:-(i) Nut, bolts and supporting structure including module mouting structure shall have to be adequately protected from atmosphere and weather prevalling in the Adampur Air Force Station. All fastners shall be of stainless steel of Grade SS 304.(ii) Two numbers of anti-theft fastners of stainless steel on two diagonally opposite comer of each module shall be provided.(iii) The rep of AO, shall visit the factory site of galvanising for each section of lot of dispatch to collect the samples at random & send the sample duly sealed & signed by him and rep of contractor to nearest NABL accredited Lab for testing. The lot will bedispatched from factory permises only after passing of sample from Lab. In case of failure of sample complete lot will be rejected. The quoted rates are deemed to include these provisions. 33 Note:- (i) cost of interconnecting copper cables along with cable trays (floors/ wall mounted) suitable to accommodate solar grade cables & cables upto invertersshall be measured and paid separately under relevant items. (ii) Earth work and foundation of MMS shall be measured and paid separately under relavent items (iii) MM structure shall be paid as per actual size installed st site. 34 M&L for tinned copper conductor, 6 Sqmm XLPO insulated and sheathed, UV-stabilized, single core multi-stranded DC cables- RED & BLACK (FOR PANEL INTER CONNECTION), complete as all specified below and directed.(1) Construction(i) tinned copper conductor IEC 60228, class-S(ii) Insulation/sheath:- electon beam cross linked halogen free & flame retardant compound (XLPO)(2) Electrical(i) Voltage Test: 6500V as per EN 50395 (ii) Max permissible operating Volatge:- DC 1.5 KV (conductor-conductor, non earthed system)(iii) Nominal Voltage :- AC 0.6/1.1 KV & DC -900/1.5 KV(3) Temperature(i) Amblent temp: (-) 40°C to (+) 90°C (ii) Max conductor temp (-) 40°C to (+) 120°C(4) Strandards & Material properties(i) Fire performance -IEC 60332-1-2(ii) Smoke emission:- IEC 610374/EN 50268-2(iii) Approval :- EN 50618, HIZ272-KMake: Polycab/Havells/Finolex/KEI India/RR KabelNote: (i) Routine testing of cable shall be carried out by rep of AO at the factory premises of OEM, before dispatch. 35 Supply and laying in trenches, 3.3 KV underground cable, XLPE insulated armoured heavy duty electric cable with aluminium conductor 3300 Volts grade, cross sectional area 300 Sqmm, 3.0 core multistranded, confirming to IS-7098 (Part-1):1988 suitable for earthed system including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as directed by Eng-in-Charge. (ACDB to LT Panel and LT Panel totransformer). 36 All same as per item No 4.17 above but size of 120 Sqmm 3.0 core (Busbar No 1 to ACDB No 1, Busbar No 2 to ACDB No 2 and Busbar No 3 to ACDB No 3) 37 M&L for 70 Sqmm 3.0 core, 1100 volts grade PVC Copper Cable flexible, conforming to IS 7098 (Part-2):1988 (Inverter No 1 to Busbar No 1, Inverter No 2 to Busbar No 2 and Inverter No 3 to Busbar No 3) complete all as specified and directed by Engr-in-Charge. 38 HT TRANSFORMER (INVERTER DUTY FOR SPV PLANT)Supply, installation, testing & commissioning of copper wound, step up cum inverter duty conforming to IS:2026 or latest IS standard, HT Transformer, outdoor type capacity not less than 1000 KVA, 0.800/11KV, 50 Hz, Dyn 11, ONAN class A for solar application, Star Delta Tapping + 7.5 % to -7.5% @ the step of 2.5% ON load type tap changer, with first filling of transformer oil as per IS:355, ISI marked , duly filtered & Dehydrated and other standard fitting/ accessories including Platform & foundation for Transformer installation as recommended by manufacturer. The total losses (No load + Full load) at 75 deg C shall not be more than 1% of rated capacity of transformer, Impendence 5%. The following are included:-(i) Name, rating & diagram plate. (ii) Tap changing switch. (iii) Earthng terminals. (iv) Lifting lugs. (v) Oil level indicator 150 mm dia with alarm & trip contact. (vi) Oil drain valve with plug (vii) Oil filter valve with plug. (viii) Conservator with oil filling hole with cap. 39 (ix) Thermometer pocket. (x) 4 Dial type thermometer stem type & with MRP. (xi) Air release plug. (xii) Silicagel breather. (xiii) Removable inspection opening on top cover. (xiv) Explosion vent. (xv) Bi-directional CI rollers. (xvi) Arching horn set. (xvii) Winding temperature indicator with alarm & trip contact. (iii) Marshalling box for 03 Nos. (iv) Magnetic oil level gaugue (v) Pressure release valve (PRV) with trip contact. (xviii) Conservator with oil filling hole with cap & drain plug and with bulit in diaphragm to avoid direct air contact with transformer oil. (xix) Oil level indicator with minimum level marking. (xx) HV cable box (xiv) LV cable box (xv) Bucholz relay with control connection upto HT VCB including testing at OEM premises.Note : Cost of PCC foundation as per OEM foundation drawing & necessary earth work (excavation, returning filling & making good to surface) shall be deemed to be included in quoted rate.Make:- GEC (Prolec)/ABB/Siemens/Schneider/ITE Gurgaon/CG Power & solution Ltd. 40 M&L for 50 Sqmm single core, 0.6/1.1 KV PVC insulated and PVC sheathed Copper flexible cable, IS :7098 complete as all specified and direcetd. (LA Top to Earth strip of pit) 41 M&L for 6 sq.mm single core, PVC insulated and PVC sheathed copper flexible cable, IS :7098 complete as all specified and direcetd. (LA Top to Earth strip of pit) 42 M&L for 1 sq.mm , 2 core, RS 485 cable twisted shielded unarmoured copper cable complete as all specified and directed (Data Monitoring Cable for communication) 43 ACDB Panel for 750 KWp Inverters (3x250 KW inverters) Design, supply, installation, testing & commissioning of outdoor type, floor mounted ACDB Panel for 750 KW Inverters having 3 incoming & 1 outgoing, IP-65 protection rating with PCC foundation for civil works (Excavation, cutting, Grouting, PCC etc) Fabrication with 3.15 mm thick CRCA sheet steel, 7 tank power coated, floor mounted panel with 40x40x6mmMS angle stand, cable entry from bottom through gland plates, internal control wiring with suitable size copper cables, cable alley, three numbers 1200 Amps aluminium bus bar EC grade incld heat shrinkable PVC sleeves complete all as specified and directed and having following switchgears :- 44 OUTGOING:-1 No.800 Amp, 3 Pole,50Hz, 3 phase, ACB Drawout type, motorised charging, with microprocessor release, Icu = Ics = Icw 50 KA,suitable for 800 volt, 3 phase, 50 Hz with ACB spreader Link with R,Y,B LED indicating light, digital Multimeter 800 volts CL-1, 3 Nos Metering CT 800/5A TP SPD Type 1+2 40 KA. INCOMING :-3 x 250 Amp, Icu = Ics = 36 KA 3 pole MCCB microprocessr released with spreader links. The panel should contains follwoing metering devices :(a) Volt meter with selecter switch -01(b) Ammeter with selecter switch -01(c) Frequency meter - 01(d) R,Y, BIndication Lamp LED type- 01 Set of three.(e) PT 800V/110V,-01 Set of three.(f) CT 800A/5A, CL-0.2, 5VA- Set of three(g) Auxiliary transformer 50 VA, 800V/230V - 01 NoNote:- Contractor shall submit drg of ACDB panel to GE for approval of accepting officer before procurement. 45 LT Panel for 750 KWp inverters Design, supply, installation, testing & commisssioning of outdoor type, floor mounted LT panel of 3.15mm thcik CRCA sheet steel powder coated for 750 KWp inverters having 1-input & 1- output, IP-65 rating, cable alley with PCC foundation for civil works (excavation, cutting, grouting, PCC etc) TP SPD,type 1+2 40 KA, MCCB extended ROHM, all cable entry from bottom through gland plates, 3 Nos control fuse 16A with base for SPD,three 1200 Amps Aluminium bus bars Ec grade incl heat, shrinkable PVC sleeves, Aluminium busbar links, internal wiring with suitable size copper cables, with 40x40x6mm MS angle stand , 7 tank powder coated, three 6A SP 10KA MCB C Curve etc complete all as shown on drawingscomplete all as specified and directed. 46 INCOMING:-1 No of 800 Amp 3 pole ACB, Icu = Ics = Icw = 50 KA- 800 Volts, drawout type, motorised charging, with microprocessor release ACB/MCCB Spreader links.OUTGOING1 No of 800 Amp 3 pole ACB, Icu = Ics = Icw = 50 KA- 800 Volts, drawout type, motorised charging, with microprocessor release ACB/MCCB Spreader links:- The panel should contains follwoing metering devices :(a) Volt meter with selecter switch -01 No(b) Ammeter with selecter switch -01 No(c) Frequency meter - 01 No(d) R,Y, B Indication Lamp LED type- 01 Set of three.(e) PT 800V/110V,-01 Set of three (f) CT 800/5A, CL -0.2 , 5VA - Set of three(g) Auxiliary transformer 50 VA, 800V/230V -01 No.Note:- Contractor shall submit drg of Panel to GE for approval of accepting officer before procurement. 47 COPPER BUSBAR CHAMBERM&L for outdoor type, floor mounted , vermin proof, totally enclosed bus bar chamber of not less than size 800 mm (H) x 800mm (W) x 600 (D) made out of 3.15 mm thick CRCA sheet , incl three number 300 Amps pure copper busbar having size of 200 MM (w) x 100 MM (thick), 0.5 Mtr length/ phase incld heat shrinkable PVC sleeves, duly supported on insulators, it shall be IP-65 rated. Cable entry from bottom and suitable for input of 70 sqmm, 1.1 KV copper cable and output of 120 sqmm, 1.1 KV XLPE cable, powder coated complete all cable entry from bottom through gland plates all as spceified and directed. 48 MONITORING SYSTEMDesign, Supply, installation, testing & commissioning of monitoring system to monitor the performance of the PV Module & inverter (Power arrray voltage, array current & AC parameters), energy yield temperature, irradiance level, humidity, Air Mass, wind velocity etc, and it could provide flexible interface to facilities PC based inverter monitioing and control via GPRS modem and internet/ethenet connection. This should have include web visulization system and data logger with integrated ethernet port. The monitoring system shall be comprises of following :-(a) 5G based plug and play RTU with smart data logger to connect inverters & sensors - 1 Set. (i) Modbus RS485 RTU. (ii) 2 Analog ports. (iii) Built in memory help store and send data in case of network failure. 49 (b) IP-67 Enclosure box (280mmx190mmx130mm) or as approved with SMPS power supply and other accessories to house the RTU - 01 No.(c) Access to web portal-server charges for 1 years data frequency 10 minutes.(i) Interractive Dashboard. (ii) Single line diagram. (iii) PR analysis. (iv) Solar radiation & weather data. (v) Graphics and reports. (vi) Generation analysis. (vii) Log reporting. (viii) String/MPPT monitoring. (ix) Plant/Inverter performance. (x) Superuser dashboard for centralized monitoring. (xi) Mobile app on android. (d) Weather sensors.(i) Solar radiation sensor with mounting kit - 01 No. (ii) Wind speed sensor with mounting kit - 01 No. (iii) Ambient temperature sensor with mounting kit - 01 No. (iv) Module temperature sensor with mounting kit - 01 No to be provided complete with readouts integrated with the data logging system. 50 (v) Analog to modbus module - 01 No. (vi) Wind direction sensor with mounting kit - 01 No.(e)All in one Desktop computer, 12 th Gen intel core i3, 21.5 inch monitor screen, FHD display, 8 GB RAM, 512 GB SSD with Window 11 including wireless keyboard and mouse complete. Make : HP / Dell/ Lenovo / Microsoft(f)Laser Jet Printer, print speed not less than 18 ppm, power consumption not more than 320 watt, capable to print on A4, A5, B5 & legal size paper, single function including power cable & USBcable, toner, installation CD and user manual complete. Make : HP / Canon/ Xerox 51 Note : The following information shall be displayed in the monitoring system:-(i) Individual module power generation, voltage, current, irradiance and temperature etc.(ii) Individual string power generation, voltage, current, irradiance and temperature etc.(iii) Total power generated of all strings, voltage, current, irradiance and temperature feeding to each invertor. (iv) input voltage, input current, output voltage, output current and power losses of each inverter.(v) Total power, voltage, current, temperature at input of solar transformer, also output parameters such as output voltage and output current of solar transformer. 52 EARLY STREAMER EMISSION (ESE)Supply, installation, testing & commissioning of 5m high, advance active on generating Early Streaner Emission (ESE) lightning arrestors with lightning counter to provide radius of protector of minimum 107 m at level-IV. The lightning arrestors shall conform to IEC 60099-4 or IS 3070 except to the extent modified in the specification. Arrestor shall be hemetically sealed units, self -supporting construction, suitable for mounting on lattice type support structurs complete as specified and directed by the EIC & shown in drawings. 53 Lightning Protection system on protective Early Streamer Emission (ESE) technology confirming by NFC 17-102-2011 and UNE 21186 Standard, Non electronics based deivce shall emit electronmagnetic impulse in the form of a streamer intothe air microseconds earilier than naturally.(i) Lightning impulse current (10/350 µs) in 100 KA tested (ii) Serial no mentioned in Each Model of Air Terminal quality certificate. (iii) Material metal housing stainless steel 304. (iv) central rod dia 20 mm elect/magnetic shielding (v) can be qualified in compliance of CPRI (central power research institute). Govt of India for the Impluse current of (8/20 µs) in 40 KA with 5 poistive & 5 negative impluse (vi) Covering radius 107 meter in Level-IV Protection with 8 mtr mast. 54 Lightning Air Terminal Adaptor. Supply of highly insulated polyplatic adaptor to fix the lighnting ESE air terminal with the mat. The adaptor shall have suitable metal connector/ connecting point in such a way the top portion shall be electrically connected to the central final trip (elevated sharp tip) of the ESE air terminal and the bottom portion shall be connected to the down conductor. 55 MAST GI (supporting mast): supply of GI mast for mounting the terminal & adaptor with the ESE air terminal i compliance with IEC 62561-1.(i) GI mast length:- 8 Mtr (ii) GI pipe heavy duty, bottom 80mm dia, 3m, middle pipe dia 65mm, 2m (iii) standard: IS 1239 Part I): 2004 (iv) Base plate: GI Base plate size (250x250x5mm) (v) both the GI mast to be connected with the help of 2 flanges with 4 GI plated nut bolt with washers. The base plate size in (300x300x6mm) GI with requisite fitted with 4 hold the mast. (v) Necessary concrete foundation, earth work for holding the lightning conductor in position is deemed to be included in quoted unit rate. 56 Guy Wire Kit: Supply of Guy wire GI Nickel coated 4mm dia. Covered with white sleeve for extra protection and avoiding rusting. Length of the Guy wire is 6 mtr x 3 no = 18 mtr with accessories like:(i) Guy wire Nickel coated with white convered waterproof sleeve-18 metre(ii) U clips - 6 nos (iii) Pin type zebra anchor fastner-4 nos (iv) O hook- type fastner/ eye bolt fastener-3 nos (v) GI nut bolt 12mm dia of suitable lenth - Nos as per site requirement. 57 Lightning Strike Counter: minimum sensitivity of 250 A at 100 KA.(i) Display Model: digital display (non- resettable type) (ii) Display Range: 000000 to 999999 (iii) Detected Maximum discharge current : 350 A, 10/350 microsecond wave (measurd according to NFC standards per IEC 60060-2)(iv) Tested as per IEC-60060-2 (v) Degree of protection : IP 65 (vii) Operating Temperature (*C): 20+~85 (viii) Strike count display 6 digt (ix) Standard NFC17 102 (2011) Make- Saboo Sysyems Pvt Ltd/KMV/ABB/Axis India Note: Item No 4.34 to 4.39 (i) Lightning arrrestor & its components shall preferably be supplied by same manufacturer. The installation shall be carried out by rep of manufacturer. Testing of LA shall be done in presence of Engineer- in- charge. 58 Chemical Gel Earthing system: Supply for advance chemical Gel earthing system of 1 No. of UL certified 7 CPRI tested environment friendly ground enhancing compund. The copper bonded rod shall be 3 mtr long, 17.2mm diameter 254 microns copper bonded steel rod surrounded with 25 Kg each or more quantity of resistance lowering grounding minerals ROHS certified. Distance between the rod shall be length of the rod all as shown on drawings.(i) Tested as per IEC 62561-2 (ii) CPRI tested at 5 positive & 5 Negative impluse 25 KA (iii) Meets the requirments as per IS 3043, IEC 60964-5-54, UL 467 (iv) Standard- As per IS-3043 & IEEE80-2000, Test certificate from NABL lab. Make : Pragati Electrocorp (P) Ltd Gurgaon / DEHN / JEF Techno 59 Pit Chamber-Round value box supply of FRP heavy duty UV resistance, weather proof earth pit cover as per OEM recommendations complete all as specified and diected. 60 M&L for UPVC pipes of 40 mm size for DC wires, having pressure capacity of 10 kg including fiting viz joints bends, tees, etc complete all as specified and directed. 61 M&L for UPVC pipes of 25mm size for DC wires, having pressure capacity of 10 kg including fiiting viz, joints, bends, tees etc complete all as specified and directed . Note:-(i) Earth work shall be measured and paid under relevant item. 62 M&L for perforated hot dipped galvanized iron cable tray having cable tray for AC & DC cable routine (300 x 50 x 5mm and 450 x 50 x 5mm) thickness 1.5 mm galvanization and perforation not more than 17.5% includeding fittings viz joints, bends, tees, etc in convenient section of length complete all as specified and directed. 63 Supply, installation, testing and commissioning of Vacuum Circuit Breaker 630 Amps, having rupturing capacity 350 MVA, HT 11 KV, 3 phase 50 Hz, indoor type, totally enclosed metal clad constructed from Aluminium Zinc sheet steel of 2mm thickness for incomer as ICOG confirming to IEC-62271-200 complete with, overload and earth fault protection, ammeter, voltmeter complete as incomer circuit breaker all as specified and directed alongwith following technical specifications:-(i) 630 Amps rating. (ii) Horizontolly draw out type. (iii) Trip rod and have RoF type & Rack in Rack out motorised type. (iv) Motorised spring charging mechanism with integral spring charging handle for manual spring charge. (v) Panel separation with every department like VCB, Metering, cable chamber & Bus bar chamber. (vi) Cast resin current transformer 11 KV, 600-300/1+1A, core 1, class 0.5, 15VA wih metering and protection core including necessary control wiring & PT 11 KV, core-I class, 3 Pole, Core-II class-0.5, 50 VA burden OVF 1.9 for 30 Second for metering & protection backed by HT & LT MCBs. (vii) Line PT should be mounted on rear side (top or bottom) of the panel. 64 (viii) Accessories like local remote switch, breaker control through MCB, indicating lamp RYB, spring charging, DC supply healthy, breaker ON/OFF breaker in service/test, multi function meter with RS-485 port (EM-6400NG), Digital Ammeter and Volt Meter, (ix) Separate master trip relay and anti pumping relay. (x) Comprehensive numerical protection relay should have built in integrated mimic compatible IEC-61850 for non-directional O/C, E/F,U/V, O/V protection type having following additional facility:-(a) Trip circuit supervision. (b) Distribution recorder. (c) Event log with date and time. (d) Conformal coating for harsh environment. (e) suitable to operate on 24 Volt DC for auxillary and control supply. (f) Fully internal arc type (25 KA for 1 second) as per latest IEC:62271-200. (g) Vacuum bottles should be tested for 100 full short circuit operations. (h) Manual closing/tripping of CB with compartment door closed. (j) The panel shall be provided with power pack battery backup for not less than 10 minutes. 65 (k) The height of the HT section should atleast be of 1400mm for human safety during the internal arc creation. (l) Breaker shall be provided with 6NO+1NC contacts for each position in service and test, (m) Wireless thermal sensor will be provided in each bus & each cable termination per panel, alongwith Zig-b contactor and the data of the same should be display on HMI. (n) The VCB shall be SCADA compatible. (o) The VCB interrupter, breaker & panel alongwith relay should be of same make for better coordination and better SCADA compatibility. 66 Supply, installation, testing and commissioning of three phase, 4 wire Bi-Directional HT CT/PT Digital Energy Meter automatic grade as per relevent IS, 110-240 V, (66 KV/Ѵ3/110/Ѵ3) industrial application, Optical Port, RS 232/485 communication current rating Imax 2A -/1A, automation grade, accuracy class 0.2s, D3M024 type and suitable to install between 66 KV Sub Station (Commercial supply of PSPCL) in replacement of existing PSPCL energy meter and 750 KWp Solar power plant, display parameters like KWh, KVArh, KVAh, KW, kVA, Frequency, Power Factor, Current, import and export of energey complete all as specified and directed by Engr-in-Charge. Make : Secure, model : Premier 300 or its technno commercial equivalent.Note : The contractor shall liaise with PSPCL for testing & calibration of the meter. Cost of the same deemed to be incuded in quoted rates. 67 ROAD/PATH/CULVERT 68 M&L for providing and marking broken centre/ side lines/zebra Lines, dashes, arrows etc on road pavement and the like of any description and width with thermoplastic paint hot applied with machine confirming to BS-3265 and according to the specification laid down by IRC and MOST (Mininstry of Surface Transpost) specification 2001 (4th revision) complete all as specified and directed. 69 EXTERNAL WATER SUPPLY 70 Construction of brick masonary valve pit of size 1000x1000x1000mm (internal dimension) with and including MS sheet cover fabricated from 3 mm thick MS sheet and frame of angle iron 40 mm x 40 mm x 5 mm with fixing arrangement hinges and locking arrangement and painting two coats of synthetic enamel paint over a coat of red oxide primer on MS cover and frame including necessary excavation and earth work in any type of soil, returning, filling in approved soil, disposal of surplus soil to a distance not exceeding 50 metre, 150 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation, brick work using pulverised fuel ash lime bricks in cement mortar 1:6, 15 mm plastering in cement mortar 1:4 both internally and externally, 100 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring complete all as specified and directed by Engr-in-Charge. 71 PVC HDPE rotational moulded 5000ltr capacity water storage tanks (Cylindrical vertical type with closed top) triple layered,fixed in position and making inlet and outlet water piping line connections complete all as specified. Note : Staging for PVC water tank shall be paid separately under respective item. 72 S&F Pumping sets, centrifugal monoblock, electric driven, single phase, 2HPhaving discharge capacity 3.2 LPS at 20 mtr head, suction x delivery size 50x40mm all as specified and directed by EIC. 73 Supply and fixing PVC air braided hose pipe 25mm dia. 74 M&L for provisioning of staging at 2 mtr height for PVC HDPE storage tank 5000ltr capacity. Note : S&F of PVC water tank of 5000 ltr capacity not included in this rate and shall be paid saparetly under respective item. 75 SEWAGE DISPOSAL WORKS 76 Supply and fixing ofLLDPE septic tank designed to carry sewage and sullage, water including excavation in anytype of soil, PCC 1:4:8, PVC Pipe from last manhole to septic tank, vent shaft, vent cowl and misc connection like PVC Tee, PVC bend etc. complete for PWTS-STBF-160-01 (1600 Lts Capacity) (Make - Sintex) 77 Soakage wells exc, in ordinary Soil, Foundation in PCC 1:3:6, wells of Honey combed and solid in M-25 Concrete, including intercepting chamber, screen chamber Brick work in CM, RCC cover slab in M-25/ RR masonry / Filling with brick bats, complete of size 1.8 M dia X 3.0M deep. (CEJZ/STD-301/90 SHEET No 1/4to 4/4) 78 EXTERNAL ELECTRIC SUPPLY 79 Supply, installation, testing and commissioning of 11 KV, 630 Amp, 50 Hz, SF6 gas insulated, 21 KA/3 Sec 3 way Ring Main Unit of outdoor type, motor operated, extensible with 01 No. VCB 630 Amps as incommer and 02 Nos LBS as outgoing cable termination from front (Internal arc classification AFLR 21KA/1 Sec with bottom exhaust both for tank and cable box as per IEC:62271-200), enclosed in welded stainless tank having IP-67 degree of protection, leak rate of SF-6 gass less than 0.1% and tested as per IEC:62271-200, ring core type protection CT, line side isolator alongwith following technical specification:-(a) Electrical specification. (i) Nominal system voltage - 11 KV. (ii) Voltage variation on supply side - + 10 (iii) Corresponding higher system voltage - 12 KV. (iv) Transient condition - (-)20% or 10% combined variation of voltage and frequency. (v) Lightening impulse withstand voltage upto 75kVp. (vi) one minute dry/wet power frequency withstand voltage primiary - 28 KV. 80 (vii) Rated dynamic withstand current - 52.5 KA. (viii) No of short circuit operations at rated short circuit current of 21 KA for breaker - 50 Nos.(b) General specifications. All live parts, bus bars, shall be preferably be enclosed in non megnetic and non ferrite grade stainless steel tank grade SS-304 of minimum 2.5 thickness. The RMU shall be tested for internal arc test of 21 KA/1 Sec AFLR with bottom exhaust for safety of personnel for both tank as well as cable compartment as per IEC:62271-200. The outdoor enclosure shall have IP-55 protection for complete switchgears with top opening canopy & dedicated IP-55 cable compartment. The protection relay shall be for 3 o/c + 1 E/F (IDMT Type) self powered numerical protection relay with low and high set of over current and earth fault, MODBUS communicating alongwith RS-485 Port. Internal Arc classification should be with bottom exhaust only. The RMU should be SCADA compatible and trouble free operation at the temperature 40 degree C & above. 81 (C) Insulated Bus connected unit comprising of the following :(i)Air insulated enclosure with necessary bus connection via bushing VTs from manufacturer and according to IS:3156. (ii) Sinle phase bus PT for metering - 11 KV/rt3/110V/rt3, 50 VA, class 0.5. (iii)Auxillary transformer - 11 KV/230V AC, 1 KVA. (iv) Multifunction Meter - EM6400 NG class 0.5 for incomer(d) The following accessories should be included in deemed rate:(i) Antireflex operating hadle. (ii) Battery 24 V DC, 12 Ah. (iii) Battery charger 24V DC. (iv) Manometer with remote contact.Note : RMU should be manuctured, inspected by rep of the Acceptung Officer and invoiced from the OEM factory. 82 Supply, installation, testing and commissioning of Vacuum Circuit Breaker 630 Amps, having rupturing capacity 350 MVA, HT 11 KV, 3 phase 50 Hz, indoor type, totally enclosed metal clad constructed from Aluminium Zinc sheet steel of 2mm thickness for incomer as ICOG confirming to IEC-62271-200 complete with, overload and earth fault protection, ammeter, voltmeter complete as incomer circuit breaker all as specified and directed alongwith following technical specification:-(i) 630 Amps rating. (ii) Horizontolly draw out type. (iii) Trip road and have RoF type & Rack in Rack out motorised type. (iv) Motorised spring charging mechanism with integral spring charging hangle for manual spring charge. (v) Panel separation with every department like VCB, Metering, cable chamber & Bus bar chamber. 83 (vi) Cast resin current transformer 11 KV, 600-300/1+1A, core 1, class 0.5, 15VA wih metering and protection core including necessary control wiring & PT 11 KV, core-I class, 3 Pole, Core-II clause-0.5, 50 VA burden OVF 1.9 for 30 Second for metering & protection backed by HT & LT MCBs. (vii) Line PT should be mounted on rear side (top or bottom) of the panel. (viii) Accessories like local remote switch, breaker control through MCB, indicating lamp RYB, spring charging, DC supply healthy, breaker ON/OFF breaker in service/test, multi function meter with RS-485 port (EM-6400NG), Digital Ammeter and Volt Meter, (ix) Seprate master trip relay and anti pumping relay. (x) Comprehensive numerical protection relay should have built in integrated mimic compatible IEC-61850 for non-directional O/C, E/F,U/V, O/V protection type having following additional facility:-(a) Trip circuit supervision. (b) Distribution recorder. (c) Event log with date and time. 84 (c) Event log with date and time. (d) Conformal coating for harsh environment. (e) suitable to operate on 24 Volt DC for auxillary and control supply. (f) Fully internal arc type typed (25 KA for 1 second) as per latest IEC:62271-200. (g) Vocuum bottles should be tested for 100 full short circuit operations. (h) Mannal closing/tripping of CB with compartment door closed. (j) The panel shall be provided with power pack batter backup for not less than 10 minutes. (k) The height of the HT section should atleast be of 1400mm for human safety during the internal arc creation. (l) Breaker shall be provided with 6NO+1NC contacts for each position in service and test, (m) Wireless thermal sensor will be provided in each bus & each cable termination per panel, alongwith Zig-b contractor and the data of the same should be display on HMI. (n) The VCB shall be SCADA compatible. (o) The VCB interrupter, breaker & panel alongwith relay should be of same make for better coordination and better SCADA compatibility. 85 (E) Indicating lamps LED type(i) Breaker ON Red clolour - 01 No(ii) Breaker OFF Green Colour - 01 No(iii) Auto Trip indication amber colour- 01 No(iv) Trip circuit heathly clear - 01 No(v) Spring charged blue colour - 01 No(vi) RYB indication - 03 Nos(F) Accessories (i) Trip Neutral Close Switch - 01 No(ii) Space heater with thermostat - 01 No(iii) Local Remote Switch - 01 No(iv) 3 Pin Plug Connector - 01 No(v) MCB AC & DC - 02 Nos(G) Relays(i) Numerical relay 50/51/50N/51N, non communicable, non draw out type - 01 No(ii) Master trip relay - 01 No(iii) Auxillary relay for transformer (3 elecments) - 02 Nos 86 M & Lfor Boring of holes under roof, pavement, hardstanding by trenchless technology using ultrasound technique and necessary machine including HDPE pipe of 75mm dia suitable for 0.4mpa working pressure all as pecified and directed. 87 Supply, fixing, testing and commissioning of junction box incl AI bus bar with MCB SP 6A, 10 KA, C curve & PVC cable 2.5 sqmm 2 core weather proof, aluminium conductor upto 7.5 mtr length for connection for single or 3 incoming cable & for outgoing and single phase connection of secuirty light fitting from junction box , PVC conduit pipe upto junction box , enclosed in tehermo plastic enclouser,shock proof , weather , dust , rust & water proof internally embedded gasket with provision for cable entry of size 300x200x125mm alongwith MS clamps, through and incl suitable gland all as specified. 88 Supply, install , testing and commissioning of LT feeder pillar distribution panel board CPRI approved, outdoor type, weather/vermin proof, mae out of 3.15 mmm thick CRCA sheet duly powder coated of suitable size and medium channel 75mm base mounting frame double door factory assembled cubicle pattern modular and compartmentalized construction, floor mounted free standing type 3 phase and netural 200 Amps current carrying capacity aluminium bus bar with epoxy insulated coating with colour code and insulated support, cable galleries inter connecting busbar connection/linkage complete and conforming to IS : 8623 and IP 54 class of protection as per IS ; 2147 complete with the following accessories and suitable for housing one incoming MCCB and outgoing MCCBs of capacity as below completed and mounting the panel board on ground with PCC (1:3:6) , bedding upto a height 30cm above ground level complete all as specified and directed (OR CH/DH) 89 (a) Aluminium busbar 200 Amp for 3 phase & netural -1 Set. (b) MCCB 4 pole 100 Amps 25 KA at 415 V -1 No (incomig)(c) MCB TPN 32 amps, 10 KA , C curve -Nos (outgoing)-02 , spare-01). (d) MCB SP 16 A , 10KA , C Curve-2 Nos (for street lights). (e) Digital Voltmeter with selector switch 0 to 500 volt- 1 No. (f) Digital Ammeter with selector switch and CTs 0 to 500 Amps-01 No. (g) Timer switch with set of contactors - 1 No. (h) LED type indicator lamps (R 90 MANNING & OPERATION (M&O) UNDER PH-II 91 First year manning and operation of 750KWp Solar Power plant round the clock by providing following staff on all days including Sunday and Holiday for trouble free functioning of the installation at Adampur to ensure maximum solar energy is fed to grid including following:-(i) Trouble free operation of the solar power plant. (ii) Monitor the performance of the solar plant by data logging. (iii) Monthly report preperation and reporting to customer on performance of power plant. (iv) Maintainance of module- periodic cleaning of module through water. (v) Schedule maintainance of invertor. (vi) Frequent testing of plant equipment by walk down checks to internal condition of equipments such as module perfomance, inverter test monitoring, system testing etc. (vii) Careful logging of operation data and periodically processing it to determine abnormal slowly detoriating conditions. (viii) Attendto emergency break down/repair of the component without any delay. (ix) Careful control and supervision of operation conditions (wide and rapid variation in voltage and frequency conditions do contribute to increase maintainance). (x) Regulate routine maintainance work such as keeping equipment clean, cleaning of solar PV Module, proper maintainance of inverters, maintainance of LT/HT cable lugs, Panels, MCCBs, Joints, 92 Transformer, VCBs etc of any type/size and capacity. (xi) Spare parts maintainance including replacement of defective parts. (xii) Securing all equipments/materials against damage/theft etc. (xiii) Keeping complete area neat & clean through spray chemicals and cleaning of grass at regular interval of time. (xiv) Servicing and maintainance of SCADA System and taking printout of all the data from SCADA once daily. (xv) The thermal imaging of PV Panels should be taken for checking its healthiness once as directed by the Engg-in-Charge. (xvi) The shutdown time of interval should be monitored and recorded. Min staff (s) to be employed (a)Sopervisor : 01 No in one shift of 8 Hrs ( 0800 Hrs to 1600 Hrs) having diploma in electrical Engg and having good knowledge of SCADA system.(b) Electrician (ITI Electrical) - 01 No in one shift (0800 Hrs to 1600 Hrs) (c) Helper (Min 10th pass) : 01 No in three Shifts. (0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs, and 2200 Hrs to 600 Hrs) 93 MANNING & OPERATION (M&O) UNDER PH-III 94 Second year manning and operation of 750KWp Solar Power plant round the clock by providing following staff on all days including Sunday and Holiday for trouble free functioning of the installation at Adampur to ensure maximum solar energy is fed to grid including following(i) Trouble free operation of the solar power plant. (ii) Monitor the performance of the solar plant by data logging. (iii) Monthly report preperation and reporting to customer on performance of power plant. (iv) Maintainance of module- periodic cleaning of module through water. (v) Schedule maintainance of invertor. (vi) Frequent testing of plant equipment by walk down checks to internal condition of equipments such as module perfomance, inverter test monitoring, system testing etc. (vii) Careful logging of operation data and periodically processing it to determine abnormal slowly detoriating conditions. (viii) Attendto emergency break down/repair of the component without any delay. (ix) Careful control and supervision of operation conditions (wide and rapid variation in voltage and frequency conditions do contribute to increase maintainance). (x) Regulate routine maintainance work such as keeping equipment clean, cleaning of solar PV Module, proper maintainance of inverters, maintainance of LT/HT cable lugs, Panels, MCCBs, Joints, 95 Transformer, VCBs etc of any type/size and capacity. (xi) Spare parts maintainance including replacement of defective parts. (xii) Securing all equipments/materials against damage/theft etc. (xiii) Keeping complete area neat & clean through spray chemicals and cleaning of grass at regular interval of time. (xiv) Servicing and maintainance of SCADA System and taking printout of all the data from SCADA once daily. (xv) The thermal imaging of PV Panels should be taken for checking its healthiness once as directed by the Engg-in-Charge. (xvi) The shutdown time of interval should be monitored and recorded. Min staff (s) to be employed (a)Sopervisor : 01 No in one shift of 8 Hrs ( 0800 Hrs to 1600 Hrs) having diploma in electrical Engg and having good knowledge of SCADA system. (b) Electrician (ITI Electrical) - 01 No in one shift (0800 Hrs to 1600 Hrs) (c) Helper (Min 10th pass) : 01 No in three Shifts. (0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs, and 2200 Hrs to 600 Hrs)
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 7
TenderDetail
Loading tenders