View Bid Results For Diode Array Tenders

We found 192 Bid Results related to diode array tenders. You can find Contractor details who won diode array tenders along with contract details in Bid awards announcements section.

Filters
Stage
170
17
5
Tender Publishing Platform
100
92
State / UT
24
32
27
15
15
11
10
9
8
8
7
7
6
6
5
5
4
4
4
2
2
2
1
1
1
Contract Value
27
98
55
11
Publish Date
0
0
0
0
0
Sector
13
121
19
15
9
7
6
5
3
2
2
1
1
1
Ownership
4
133
25
22
12
Within keyword
Active filters:
Showing 1–4 of 192 tenders matching your filters
1.
Power #11347336 AOC
Bids Are Invited For Vertiv 200 Kva Ups Hall Effect Sensor , Vertiv 200 Kva Ups Fan Axial 230 Vac , Vertiv 200 60 Kva Ups Fan Axial 8 Inch , Vertiv 200 Kva Fuse Ups No Lead Glass Cartridge 10 Amp 250 Vac , Vertiv 200 Kva Ups Fuse630 Amp 690 Vac 200 Ka , Vertiv 200 Kva Ups Fuse 1250Amp 690 Vac 200 Ka , Vertiv 200 60 Kva Ups Pca Cdcs Fp60z , Vertiv 200 Upsthyristor It Avg 1200 Amp , Vertiv 200 60 Ups Capacitor , Vertiv 200 Kvaups Igbt Heatsink Mounted Single Module , Vertiv 200 60 Kva Ups Pca Igbt Driver For Synergy Sx Rohs , Vertiv 200 60 Kva Ups Igbt Interface Card , Vertiv 200 60 Kva Ups Fuse 400 Amp 690 Vac 200 Ka 91500Amp Sq Sec , Vertiv 200 60 Kva Ups Pca Rectifier Scr Firing Pcb 10P218122002 , Vertiv 200 60 Pca Ups Fuse Fail Card For 360 Vdc For Hipulse F And Hipulse D Fp , Vertiv 200 Pca Ups Low Voltage Interface For Fp 60Z Set Ii , Vertiv 200 Kva Upsdiode Diode Module Heat Sink Mountable 188 Amp Rms , Vertiv 200 60 Kva Ups Pca Dic Card 710 02821 , Vertiv 200 60 Kva Ups Pca Dic Card 710 02995 , Vertiv 200 60 Kva Ups Pca Smps Pcb For Synergy Sxv , Vertiv 200 60 Kva Ups Pca High Volttage Interface , Vertiv 200 60 Kva Ups Fuse Ceramic 4 Amp 500 Vac 41 Amp Sq Sec , Vertiv 200 60 Kva Ups Pca High Frequency Converter Card 60V , Vertiv 200 60 40 30 15 10 Ups Fuse No Lead Glass Cartridge 4 Amp 250 Vac , Vertiv 200 60 Pca Cib Ups Interface Pcb 1Oz Base Cu 2 Layer Pth , Vertiv 200Kva Ups Aluminum Electrolytic , Vertiv 200 Ups Hall Effect Sensor 600 Amp 0 To 1000 Amp , Vertiv 60 Kva Ups Electrolytic Screw Lead 10000 Uf , Vertiv 60 Kva Ups Fan Axial 6 Inch 230 Vac 1 Phase 50 Hz , Vertiv 60 Kva Ups Fuse Semiconductor 500 Amp 690 Vac Fast 200 Ka 170000 , Vertiv 60 30 40 Kva Ups Hall Effect Sensor 300 Amp , Vertiv 60 Kva Ups Igbt Dual Module 474 Amp 1200 V D56 , Vertiv 60 Kva Ups Thyristor Heat Sink Mounted Module 190 Amp Average , Vertiv 60 30 15 Kva Ups Hall Effect Sensor 200Amp 0 To600amp Open Loop15v , Vertiv 60 Kva Ups Thyristor Heatsink Mounted Dual 1000 Amp Rms 570 Amp , Vertiv 60 Kva Ups Transformer Pr1 120V Pr2 120V S1 15V , Vertiv 60 Kva Ups Control Transformer Pri 0 60V 50Khz , Vertiv 60 Kva Ups Fuse Glass Cartridge 5 Amp 250 Vac 5Mm X 20Mm , Vertiv 60 Kva Ups Hall Device 400 By 4V Hta 400 S Lem , Vertiv 60 Kva Ups Single Phase Bridge Rectifier 35Amp 1200 V Gbpc35 Rohs , Vertiv 60Kvaups Diode 3 Average 35Amp Ifsm 400Amp I2t 1030 A2s , Vertiv 40 30 10Kva Ups Capacitor 100 Uf 370 Vac 5 To 10Percent , Vertiv 40 30 15 Kva Ups Capacitor Al 10000Uf 350Vdc , Vertiv 40 Kva Ups Diode Scr 150 Amp Rms 95 Amp Average 1600 V , Vertiv 40 30Kva Ups Fan Centrifugal 230 Vac 1 Phase 50Hz 50 Deg C , Vertiv 40 30 15 10 5 Kva Ups Fuse Semiconductor 110 A 6500 Amp 690 V , Vertiv 40Kva Ups Fuse Semiconductor 315A 690Vac 500Vdc 910000A 690 V , Vertiv 40 Kva Ups Fuse 355 Amp 690 Vac 500Vdc 140000 A 660 V , Vertiv 40Kva Ups Igbt Dual Module 474 Amp 1200 V D56 , Vertiv 40 30 15 10 5 Kva Ups Pca Dc Dc Converter 28 V 1093Db 2 , Vertiv 40 30 15 10 Kva Ups Pca Clamping Diode Array Card 796Db 4 , Vertiv 40 30 15 10 5Kva Ups Pca Manis Feedback 3 Phase , Vertiv 40 30 15 10 5 Kva Ups Transfomer Control Isolation Copper Crgo , Vertiv 40 30 15 10 5Kva Ups Pca Input And Output V Feedback Card 240 Vdc , Vertiv 40 30 15 10 Kva Ups Pca Driver Square Wave Supply Cardr , Vertiv 40 Kva Ups Pca Static Switch Control Card 1 Phase 1078Db 3 , Vertiv 40 30 15 10 5 Kva Ups Pca Input And Output V Feedback Card 230 Vac , Vertiv 40 30 Kva Ups Pca Rectifier Pulse Amplifier And Rc Card 1201Db 1 , Vertiv 40 30 15 10 5 Ups Pca Micro Proceessor Based Smd Buck Boost Control , Vertiv 40 Ups Dc Converter Wrb1205cs 2W , Vertiv 40 30 15 10 5 Upspca Igbt Driver Card One Way With Square Wave Supply , Vertiv 40 30 Kva Ups Transfomer Pri 415 V Sec 230 V 400Mamp Class H , Vertiv 40 30Kva Ups Transfomer Auto 0 230 415V 1Amp At 230 V , Vertiv 40 30Kva Ups Capacitor Alum Electro 10000Uf 315Vdc , Vertiv 40 30Kva Ups Pca Dc Dc Converter Card Input 220 V Output 30 V , Vertiv 40 30 Kva Ups Fuse Clip Pcb Mount Glass Cartridge 15 Amp 500 Vac , Vertiv 40Kva Ups Thyristor Heatsink Mounted Dual 250 Amp Rms 156 A 1600 V , Vertiv 40Kva Ups Pca Data Logger For 1Phase Systems 1Oz Base Cu 2 Layer Pth , Vertiv 40 30 15 10 5 Kva Ups Pca Inverter Control Card 1 Phase 169 , Vertiv 30 15 10 Kva Ups Scr Diode Module Power 55 Amp 1600 V Rohs , Vertiv 30 15 Kva Ups Fuse Semiconductor 200 Amp 690 Vac 18500 A 690 V , Vertiv 30 Kva Ups Igbt Dual Module 324 Amp 1200 V D56 , Vertiv 30 Kva Upsthyristor Dual 150 Amp Rms 95 Amp Average 1600 V , Vertiv 30 15 10 5 Kva Ups Pca Static Switch Control Card 1 Phase 1077Db 4 , Vertiv 30 15 Kva Ups Transfomer Control Isolation Copper Pri 0 415 V , Vertiv 30 Kva Ups Transformer Power Isolation Copper 1 Phase 34Kva , Vertiv 30 15 5 Kva Ups Pca Data Logger 875Db 11 For 1Ph Systems Cu Pth , Vertiv 15 10 Kva Ups Pca Dc Dc Converter Card Input 240 V Output 30 V , Vertiv 15 10 5 Kva Ups Pca Half Control Rectifier Driver Card 3 Phase , Vertiv 15 Kva Ups Hall Effect Sensor 100 A 0 To Plus 300 A Plus , Vertiv 15 Kva Ups Transfomer Control Isolation Copper 1 Phase 17 Kva , Vertiv 15 Kva Ups Capacitor Al 3300Uf 450Vdc Plus 20 Percent , Vertiv 15 Kva Ups Capacitor 100 Uf 550 Vac 5 To10percent , Vertiv 15 5 Kva Ups Fan Axial 6 Inch , Vertiv 15 10 5 Kva Ups Hall Effect Sensor 50 Amp , Vertiv 10 5 Kva Ups Capacitor 2200 Uf 450Vdc , 10 5 Kva Ups Capacitorscrew Lead 4700 Uf 350 Vdc , Vertiv 10 Kva Ups Fan Axial 4 Inch 230 Vac 1 Phase 50 Hz , Vertiv 10 5Kva Ups Igbt Heatsink Mounted Dual Module 100Amp , Vertiv 10 Kva Ups Pca Data Logger Card For Fb50z 3100 , Vertiv 10 5 Kva Ups Hall Effect Sensor 100 Amp Panel Mounting Has , 10 Kva Ups Transfomer Power Isolation Copper 1 Phase 11 Kva , Vertiv 5 Kva Ups Diode Scr Module Heat Sink Mountable Power Rectifier , Vertiv 5 Kva Ups Thyristor Heatsink Mounted Dual 95 Amp Rms 1600 V , Vertiv 5 Kva Ups Transfomer Control Isolation Copper 1 Phase Class H Crgo , Vertiv 5Kva Ups Pca Dc Dc Converter Card Input 120V Output 30V , Vertiv 5Kva Ups Igbt 150 Amp 1200 V 1.8 V , Vertiv 5Kva Ups Transfomer Power Isolation 1Phase 5.2 Kvaclass H Crgo Total Quantity : 368
Contract Date: Ref. Documents Contract Value : 42.33 Lakh
Boards / Undertakings / PSU No of Bidders 1
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 41.30 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Contract Date: Jun 01, 2026 Contract Value : 44.96 Lakh
Government Departments No of Bidders 1
West Bengal View Result →
4.
Defence #11097521 AOC
Tender For Provision Of One Mega Watt Solar Power Project Under Ge (I) (P) No 2.; 1 Supply and fixing of MS fabricated office container of size 15x8x8.5 feet with toilet cabin of size 5x4 feet for SCADA panel and local monitoring for accomodating portable shelter , office, or living space in high alttitude cold region with including PCC flooring work for installation of container including fixing arrangement completeall as specified and directed.Location conditionTemparature range -30 °C to +25°CAltitude -3500m above sea levelwind speed upto 120 km/hSnow load high (snow accumulation on roof)Readymade container shall include the following(a) Attached toilet with EWC/IWC pressure jet gun, water tap, exhaust fan, corner wash basin, tiles flooring, water tank stand , gyser provision, wall mixer and other accessories required for said locations conditions. 2 (b) Container shall include bottom frame 100mmx50mm C channel ISI marked, Top frame of size 50mmx50mm MS square pipe ISI marked , stiffener bottom 100mm x50mm, 50mmx25mm, 25mmx25mm MS square pipeISI marked stiffener top 50mmx25mm, 25mmx25m MS square pipe ISI marked, side post 50mmx50mm, 50mmx25mm MS square pipe ISI marked, Side wall stiffness specially formed CR sheets of thicknes 1.2mm internal wall panelling 8mm thick MDF and all vertically and horizontal corner will be nealty and smoothly finished with aluminium section and L angle, Roof outside 1.2mm thick sheet of make properly sloped and water tight, false ceiling 9mm thick and smoothly finished with aluminium section and L angle, flooring 18mm thick cemented board of make visaka industries will be fixed by means of self taping screw and 1.5mm thick PVC vinyl carpet will be fixed on the panel (100% water termite and dimensional proof with veyl carpet) Aluminium windows double shutter sliding aluminium powder coated windows of thickness of 1.2mm with 4mm thick glass of make saint Gobin for all windows safety grill from outside and canopy above the floor frame work by tubular pipe of 25x25, Door with lock and handles with hydraulic door closer. Insulation 25mm thick glass wool insulation of density 65kg/m3 on side wall and 50mm on ceiling , all wiring will be PVC insulated copper wires of ISI quality, suitable for 240 volts 50 bukhead, switches and socket of 6Amp of ISI make. Split air conditioner point 16Amp alongwith seperate MCB earthing point will be provided for safety. Outside painting with 1 coat of Epoxy primer with 2 coats of epoxy paint and specially formed hooks for easy lifting and shifting. 3 Material and Labour for Plain fillets 2nd class softwood . square, rectangular or triangular in section, clean sawn, secured with screws of size exc 13 and not exc 25 Sqcm complete all as specified and directed. 4 Material and Labour for for prepration of wooden surfaces and applying a coat of pink primer for filletsof surface of any description not otherwise described over 10cm in width or girth complete all as specified and directed. 5 Material and Labour for50mm thick bonded mineral wool blanket slab made from rock, density 48kg/Cum and fixed as per manufactures instruction complete all as specified and directed. 6 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on walls complete all as specified and directed. 7 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on ceiling complete all as specified and directed. 8 Material and Labour for cement concrete type D2 1:4:8 (40mm graded agg)as in foundations filling mass concrete and all as specified and directed. 9 Material and Labour for Pre-cast cement concrete block masonry with solid blocks in 1:3:6 type C-1 using20mm graded crushed stone aggregates, exc. 10 cm in width or girthand setting in mortar 1:6, complete all as specified and directed. 10 Material and Labour for 100mm thick cement concrete 1:2:4 type B-2 using 40mm graded crushed stone aggregates as in flooring finished even and smooth without using extra cement complete all as specified and directed. 11 Material and Labour for renderring 15mm thick in CM 1:4 on fair faces of concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. 12 Material and Labour for renderring 15mm thick in CM 1:4 on stone masonry surfaces finished even and smooth without using extra cement complete all as specified and directed. 13 Material and Labour for Walling of random rubble masonry, uncoursed well bonded bedded and solidly hearted built in CM 1:4 and flush pointing the surface in contact with earth in same mortar as the work proceeds complete all as specified and directed. 14 Supply and fixing of50mm thick PUF insulated water tank of capacity 5000 litres complete all as specified and directed. 15 Supply and fixing of50mm thick PUF insulated water tank of capacity 1000 litres complete all as specified and directed. 16 Supply, installation, errecting ,testing and commissioning of On grid connecting on ground Mono Perc half Cut Bifacial Solar photo voltaic (SPV) generation plant of capacity 825KWp DC capacity at standard test condition and750 KW AC capacity (Net capcity after derating), at CHUMATHANG for fixed on module mounting structure without tracking component including solar grade copper cable of suitable sizes upto Invertor,UPS for auxilliary supply to SCADA, string array combiner/ array junction boxes comprising of following sub components/sub systems including all necessary protection, control switches and relays as required for smooth functioning of the system and meeting the specifications as given and directed by Engineer-In-Charge, the quoted rates includes all components/accessories as given below and required from Solar panel to upto step up transformer 1000 KVA incomer termination complete all as specified and directed. 17 (A) Solar photo voltaic plant- : To obtain cumulative 825KWp, three tables of nearly equal size table (varaiation of 5% between table size is permissible) ofthe input of mono perc Half Cut Bifacial silicon solar PV modules of minimum or more than 540/545 Wp with minimum or more than 144 Nos solar cells preferably per module of standard size and weight as per NISE standard , frame anodised aluminium frame (double walled) with junction box IP 65 rated , each having efficiency more than 21% at standard test condition, fill factor more than 0.79 performance ratio equal to and greater than 78 % & made of high transmittivity glass as per NISE standard tempered and glass front surface shall give high encapsulation gain. (transmittance above 90% and bending less than 0.3%) Electrical parameters of 540/545 Wp solar PV module under STC of irradiance 1000 W/m2 , AM 1.5 Spectrum at temperature 25° C will be as under or higher :-Min Peak power Pmax : 540/545 Wp or higher, Current at Pmax Ipm : 12.97A Voltage at Pmax Vpm : 41.65 Volt Short circuit current Isc : 13.85 A Open circuit voltage Voc : 49.50Volts , Maximum series fuse rating : 30A (i) Rated output of modules shall have positive tolerance of minimum 3% & no negative tolerance is allowed. (ii) It shall perform satisfactorily in relative humidity 100% with temperature -35° C to +35° C (Cell) and should withstand wind 198 Km/Hr on the surface of the panel. (iii) PV modules must be warranted for their output peak watt capacity, which shall not be less than 90% of the initial value at the end of 10 years and 80% of the initial value at the end of 25 years. (iv) The temperature co-efficient for the module shall be suitable for CHUMATHANG (UT Of Ladakh) climatic conditions. Variation of higher capacity Solar PV panel is permissible subjected to that performance parameter of the panel shall be equal or better than given above.v) PV module must confirm to latest edition of IEC 61215/IS14286 and as specified here-in- after in particular specification In addition, the modules must confirm to IEC 61730 Part-I & II for construction and testing & safety qualification. (vi) It shall also in conformity of latest technical specifications issued by MNRE from time to time (vii) Provision of earthing & earth strip/cables etc. for earth for solar PV module/Array etc. as per latest IS/MNRE norms to be provided and the cost of the same is to be included in this item and no extra amount will be paid to the contractor on this account.Notes: On SPV (i) The specifications and capacities of plant equipments shall be designed to confirm and achieve the minimum of efficiency and performance guarantees as laid down in this bid documents. These design details and other technical details shall be submitted by contractor on commencement of contract as early as possible but not later than one month(ii) The installed system should be such that during the day, the power needs should be first met by Solar energy. In case the solar energy production is less than the required, the deficit power should be pulled from the exsiting DG set supply .(iii)The contractor shall obtain the approval of make for the proposed SPV module from accepting officer complete system of 825 KWp Solar photo voltaic (SPV) (iv) Any necessary item required for functioning of SPV but not catered in the contract will be deemed to be included in the quoted rate and nothing extra will be admissible on this account 18 .(v) Site clearance incl removal of boulders to a distance 250 m to 500m to be carried out before execution of work. Amount required for site clearance is deemed to be inclulded in the amount quoted by Contractor against this item. Contractor is advised to visit the site before quoting the rate. (vi) Country of origin for solar cell & PV module must confirm to ALMM APPROVED LIST OF MNRE.(B) String array combiner/Junction Boxes: Supply & fix suitable Numbers of dust, vermin and waterproof Array string array combiner/Junction Boxes and main junction boxes made of FRP/Thermo Plast with IP65 protection in compliance with IEC62208 and shall be sunlight /UV resistant a well of fire retardant including over voltage protection, surge protection and maintenance free earthing as per relavant standard. The string array combiner/Junction boxes shall have suitable arrangement of followings:(i) Strings are required to be connected to the busbar through individual fuses. Provide arrangement fordisconnection for each of the groups (ii) Provide a test point for each subgroup for quick faultlocation & to provide group array isolation. (iii) Each array junction box will have suitable by pass &reverse blocking diodes for maximum DC blocking voltage of 1500V with suitable arrangement for its connection. Reverse blocking & by-pass diodes shall work for temperative extreames & shall have efficiency of 99.98% conformed by appropriate IEC standard. Note:- String array combiner/ junction box shall be carried out as per approved SLD.(C) Cabling : (i) Supply and fixing suitable size of XLPO insulated copper cable as per load of solar grade, 1800 V DC/1100 V AC or higher DC voltage rating, confirming to TUV 2 pfg 1169/08.2007 PV1F and latest IEC codes & IS codes for Solar Cables. (ii) All cables and connectors for use of installations shall be of solar grade which can withstand harsh environment conditions including high temperature, UV radians, rain. humidity, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS in standards. (iii) All cables/wires shall be provided with UV resistance printed copper ferrules for DC side. (iv) Size of cable from PV module to invertor shall be minimum 6 sqmm 1 core multistranded copper UV protected solar cable to be provided. (v) Cable Batch No./Drum No., IS code & size make should be printed/embossed at every one metre. (vi) The wiring of modules interconnection shall be in suitable size GI/HD pipe. (vii) Size of wire - 3.70mm dia with tolerance limit (+/ -) 0.08mm. (viii) Size of aperture - 80mm x 100mm (ix) Woven double twisted, hexagonal shaped Zn + PVC coated wire mesh type 80 x 100mm of wire 3.70mm dia wire as per IS 16014. The wire used for the manufacture of wire mesh shall have minimum tensile strength of 350N/mm2 and elongation shall not be less than 10% in accordance with IS 16014.To be laid in DWC pipe of suitable size. (xi) Solar inverter to ACB Panel, connection aluminium XLPE conductor cable of size 185 sqmm x 3C 1.9/3.3 KV rating Note : Cost of interconnecting copper cable (AC & DC), Al XLPE cable from Solar Invertor to ACB panel and cable tray above upto inverter and LT panels and upto LT side of transformer as per site requirement at the location as directed deemed to include in the item quotated rates and no extra payment will be made to contractor on this account. LT Panel shall be paid seperately. 19 (D) Module Mounting Structure (MMS) : Supply, design & fixing support structure MS hot dipped galvanised (80Micrones) including PCC 1:2:4 type B-1 for each support / foundation for civil works (excavation and earth work cutting, grouting, PCC etc.) and fixing the mouting arrangement suitable for PV solar modules & to withstand minimum horizontal wind speed of 198km/hr. The mounting structure is of mild steel hot dipped galvanised. The array structure shall be so designed that it will occupy minimum space without sacrificing the output from Solar PV panels. Nut bolts, supporting structures including module mounting structures shall have to be adequately protected from atmosphere and weather prevailing in the area. All fastners shall be of stainless steel of grade SS316. Two numbers of anti-theft fasteners of stainless steel on two diagonally opposite corner of each module shall be provided.Note: (i) Cost of interconnecting copper cables along with cable trays ( floor/ wall mounted ) suitable to accommodate solar grade cables & cables upto inverter is included in the item and no extra payment will be made to contractor. (ii) The module mounting structure shall be carried out as per approved drawing of foundation MMS. MMS foundation shall be designed as per IS 456:2000 and IS 13920:2016 and drawings shall be approved by GE before execution. (iii) The MMS stub/column,rafter,purlin ,ties and bracing members shall conform to following indian standard :IS 2062 -Hot rolled medium and high tensile structural steel ,IS 811-Cold formed light gauged structural steel section ,IS 1161-steel tube for structural purposes, IS4923- Hollow steel section for structural use. Minimum grade of steel sections for conforming to IS 811 and IS 4923 shall be E350 conforming to IS 2062 and Yst 310 conforming to IS 1608 respectively.(E) Lightning Protection for PV Array :- Supply & fix Lightning Arrestor of the required number of suitable Early Streamer Emission (ESE) lightning arrestors installed in the array field. Lightning arrestors/surge arrestors shall conform to IEC 60099-4 or IS:3070 except to the extent modified in the specifications. Arrestors shall be of hermetically sealed units, self-supporting construction, suitable for mounting on lattice type support with the following :-(i) The air terminal should be capable of racking the lightning stroke 60 micro seconds earlier as compare to passive lightning rod. (ii) The air terminal is Early Streamer Emission (E.S.E.) type which shall be fixed at the top of a GI elevation pole with base so as be at least 2 meters above the structure to be protected. Its height above roof level would be dependent on the level of protection and the protection radii required (iii) The air terminal should be working on the principle of early streamer emission using non-radioactve technology, needing no external power source. (iv) The air terminal is of stainless steel and it has qualified diameter to resist high values of lightning currents. (v) Roof connecting pipe should be capable of withstand in lightning strikes having dimension 50mm ID and 60mm OD. The terminal adaptor having inner dia 60mm OD. Lightening protection shall be provided as per approved Drg. 20 (F) Earthing system for PV array field :-Earthing system shall comply with latest revision andamendment of the relevent IEC standard and IS codes. (i) All PV module ,module mounting structure (MMS) and string monitoring unit (SMU) structures in the PV erray field shall be connected to the earthing system (ii) Each PV module frame shall be earth using copper wire of sufficient cross section area. Earthing complete with copper earth plate electrode 600×600 ×3.15 mm thick electrode, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to 20x3 mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and 40mm dia GI pipe light grade for protection of earth strip and 20mm dia meduim grade for water funnel with wire mesh complete connected to earthing test point as per SSR Part-I 2009 all as specified and directed including testing on completion.NOTE:- Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(G) Solar Inverter : Supply, fixing, testing and commissioning of minimum of suitable capacity in suitable Nos as per 250/255 KW (Total capacity of Inverters shall not be less than 750/755 KW after derating with three inverter) for CHUMTHANG 50 Hz , 3 phase 800V,185A Grid Connected Solar inverter outdoor type suitable to convert DC power of solar PV module/array to AC for further feeding to stepup transformer conforming to IEC-61683 for efficiency, IEC-62109(1&2) or equivalent for safety & IEC-62093 for reliability. The input D.C. tech specification of inverter are as under and as per approved design.(i) Operating temperature :-40ºC to + 35ºC,(ii) Relative humidity (Non condensing) upto 95%.(iii) The inverter shall consist of associated control, protection, data loging device and remote monitoring hardware. the inverter shall be suitable for operation at Chumathang .Alt 4200 mtr and min - 40ºC temperature.(iv)The inverters shall have minimum protection to IP65 and minimum European efficiency 99% load as per IEC 61683 standard.(v) The inverter shall adjust voltage and frequency levels to suit the existing DG Sets/AC power supply. (vi) The inverter shall be self-commulated with pulse width modulation (PWM) technology and shall be capable of synchronize maximum within 1 minute.vii) Maximum power point tracker (MPPT) conforming IEC- 62093 shall be integrated in the inverter to maximize energy drawn from the solar PV array. (viii) The inverter shall include appropriate self protection & self diagnostic feature to protect itself and the PV array from the damage in the event of inverter component failure or from parameters beyond the inverters safe operating due to internal or external causes. 21 (ix) Inverter shall have protective arrangement against ground leakage faults, over voltage & over current. (x) Inverter shall have arrangement for adjusting DC input current & shall trip against sustainable fault down stream and shall not restart till fault is rectified. Notes: (i) If the solar inverter as specified here-in-before is not available in the market , contractor will provide the same of higher capacity as available in the market without any extra cost. (ii) All suitable size of copper cables as per load requirement from SPV systemto inverter for interconnection purpose shall be provided by the contractor and deemed to be included in quoted rates. (iii) Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(H) Uninterrupted power supply(UPS) : Supply, installation, testing & commissioningof 110V/40A Float Cum Boost Battery Charger unit includingbattery bank comprising 50 Nos of 2 Volts-65 AH sealed maintenance free battery.The CCCV battery charger consisting ofcopper wound,air cooled transformer, 01 Set single phase full wave bridge rectifier consisting ofdiodes andSCRs, liberally rated mounted on heat sink andcomplete with resistor/condenser network for surge supperssion .During auto float mode automatic changeover shall take place from float mode to boost mode and vice versa, 01 Set of solid state constant potential controller to stabilize the DC output voltage of the float cum boost charger, 01 No electronic controller , DCdigital ammeter,DC digitalvoltmeter, Potentiometer , DC, MCB for reverse battery protection . The charger should have alarm annunciation with visual and audible alarm with manual reset facility forfuse fail alarm. Float cum boost battery charger and DC distribution board shall be housed in powder coated sheet steel cubicle with panels of 1.6mm thickness , louvers for ventilation , gland plate will be provided for cable entry from bottom .The battery charger shall be divided into two compartments.The upper compartment shall house the battery charger & DCDB with all necessary controls. The lower compartment shall be suitable for housing the batteries. Tech specification shall be as under:-(a) Input working voltage-180 -270 Volts(b) Nominal Input Voltage - 230 V , AC , 50 Hz,1 (c) On load input power factor- > 0.8 (d) On load unit watt efficiencies-> 80%(e) No load losses of complete charge-< 10% (f)Ripple contents on the load (RMS)= 1% to 5% (g) Over load - 110% for 30 minutes and will give visual indication for over load condition. (h) Boost charging - 2.4 V/Cell . (j)Float charging -2.15 V/Cell (k)Float cum boost charging-Automatically changes from one state to another state as per battery condition and will give the visual indication for either float or boost based on charging mode. (l)Reverse polarity -No damage will caused .A visual indication for reverse polarity will appear with an audio alarm. (m)Short circuit-MCB protecton provided. Make of battery charger. Statcon/Sinetrac/Amar Raja Make of batteries. Exide/Amaron/Okaya(n) The battery bank system shall be designed to supply power to following loads :-(i) SCADA(ii) Inverter auxillairy supply 22 (iii) Capacity of battery bank shall be done considering the above mention load at power factor of 0.8 lagging inclusive of 10% design margin at 50ºC.Note:- All suitable size of copper cables as per load requirement for interconnection to above loads here-in-before shall be provided by the contractor and deemed to be included in quoted rates(J) DATA ACQUISITION SYSTEM/PLANT MONITORING & SCADA :- Supply,fixing,testing and commissioning of SCADA system Monitoring system with 65 inch Screen at site with Local LDMS and for Remote Monitoring 55 inchs screen in Engineer-in-charge office to be provided for the performance of the SPV on cloud. plant, inverter ,power, array voltages, array currents & AC parameters,energy yield, temperature,irradiance level etc. and it could provides flexible interface to facilitate PC based inverter monitoring and control via GPRS modem and internet/ethernet connection. This should have include web visualization system and data logger with integrated ethernet port. (i) Data acquisition System shall be provided for each of the solar PV plant. (ii) Data Logging Provision for plant control and monitoring, time and date stamped system data logs for analysis with the high quality, including latest version available of PC & Printer. Metering and Instrumentation for display of systems parameters and status indication to be provided (iii) Solar Irradiance: An integration Pyranometer/Solar cell based irradiation sensor (along with calibration certificate) provided, with the sensor mounted in the plane of the array. Readout integrated with data logging system. (iv) Temperature: Temperature probes for recording the Solar Panel temperature and ambient temperature to be provided complete with readouts integrated with the data logging system.(v) The parameters like AC Voltage, AC Output current, Output Power, Power factor, DC Input Voltage, DC Input Current, Time Active, Time disabled, Time Idle, Energy Produced, Protective function limits (Viz-AC Over voltage, AC Under voltage, Over frequency, Under frequency ground fault, PV starting voltage, PV stopping voltage etc are accessible via the operating interface display in real time separately for solar power plant. (vi) All major parameters available on the digital bus and logging facility for energy auditing through the internal microprocessor and read on the digital front panel at any time and logging facility (the current values, previous values for up to a month and the average values) should be made available for energy auditing through the internal microprocesor and should be read on the digital front panel. (vii) PV array energy production: Digital Energy Meters to log the actual value of AC/DC voltage, Current & Energy generated by the PV system provided. Energy meter along with CT/PT should be of 0.5 accuracy class. (viii) Computerized DC String/Array monitoring and AC output monitoring shall be provided as part of the inverter and /or string/array combiner box or separately (ix) String and array DC Voltage, Current and Power, Inverter AC output voltage and current (All 3 phases and lines), AC power (Active, Reactive and Apparent), Power Factor and AC energy (All 3 phases and cumulative) and frequency shall be monitored. (x) Computerized AC energy monitoring shall be in addition to the digital AC energy meter. 23 (xi) The data shall be recorded in a common work sheet chronologically date wise. The data file shall be MS Excel compatible. The data shall be represented in both tabular and graphical form (xii) All instantaneous data shall be shown on the computer screen. (xiii) Provision for Internet monitoring and download of data including recharging shall be also incorporated till the duration of contract. (xiv) Software shall be provided for USB download with life time license and analysis of DC and AC parametric data for individual plant (xv) Remote Server and software for centralized Internet monitoring system shall be also provided for download and analysis of cumulative data of all the plants and the data of the solar radiation and temperature monitoring system. (xvi) Ambient /Solar PV module back surface temperature shall be also monitored on continuous basis. (xvii) Simultaneous monitoring of DC and AC electrical voltage, current, power, energy and other data of the plant for correlation with solar and environment data shall be provided. (xviii) Remote Monitoring and data acquisition through Remote Monitoring System with latest software/hardware configuration and service connectivity for online/real time data monitoring/control complete to be supplied and operation and maintenance/control to be encurred by the supplier. Provision for interfacing these data on Engineer-In-Charge Computer/display device and portal.NOTE:- The cost of all equipments , internet, ethernet connections, connected cables, Server, printer etc. are included in this item All licensee of windows server, MS office or any other software required for functioning of SCADA is deemed to be included in quoted rates for life time. Recharge of GPRS/3G/4G/5G network for 5 yrs from date of completion shall be reponsibilty of contractor and rates quoted are deemed to include the same. Training: On successful commissioning of the plant, training shall be provided on Plant operations and maintenance to a team (Engineers and Technician/Operations) as nominated by GE for 07 days at the time of handing over of solar plant after completion of phase-I.K) WEATHER MONITORING SYSTEM : Complete one set for Chumathag As a part of weather monitoring system the contractor shall provide the following measuring instruments with all necessary software and hardware required to integrate with SCADA.(i) Pyranometer : The contractor shall provide minimum 04 Nos of secondary standard pyranometer (ISO 9060 classification alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specificiation of the pyranometer shall be asfollows:- Spectral response : 0.31 to 2.8 micron ,Time response (95%) : Max 15 second ,Nonlinearity ± 0.5% ,Temperature response : ± 2% ,Tilt error <± 0.5% ,Zero offset thermal radiation ±7W/Sqm ,Zero offset temperature change ± 2 W/Sqm ,Operating temperature range O ºC to 80ºC ,Non stability Maximum ±0.8% ,Resolution minimum +/- 1 W/Sqm : Output Analog 4-20 mA, ,Digital RS 485 Each instruments shall be supplied with necessary length of cable calibration certificate with calibration ,traceability to world radiation reference(WRR) or world radiation centre shall be furnished alonwith the equipments.The GE reserves the right to check the calibration at the expense of the contractor. 24 The signal cable length shall not exceed 20 m .The contractor shall provide instrument manual in hard and soft form.(L) Protection switch gears: Supply, installation, testing and commissioning of factory made outdoor type, LT panel weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick with internal partition of 1.6 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2000 Amp, outdoor type , frame factory fabricated , duly powder coated painting having thickness not less than 100 microns provided suitable gasket, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, including the following :- (a)ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection. (b) MCCB 400 A, 4 pole, 415 volts, 50 Hz - 03 Nos (C) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 800 V duly moounted on porcelain insulators -01 Set (d) Digital amp meter 3 ph programmeable type with suitable1600 Amps -01 Set (e)Digital volt meter 3 ph programmeable type with suitable0- 800 volts -01 Set (g) CT 1250/5A/5A, PT 100VA CL 0.5/3P (h) LED phase indicator (RYB )-01 Set. All DC & AC circuits shall be suitably protected using appropriate circuit breakers and isolators, fuses and relays annunciator & system condition displays. Protection switchgears on AC side shall have LT ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection based with overload ,short circuit over voltage, under voltage, over frequency , under frequency , earth fault and instantaneous over current protection unit , electrically operated with manual spring charge facility , having indication for earth /over load /overvoltage/ under voltage/ over frequency/ under frequency complete with digital meter. Note:- Panelshall be provided as per approved SLD.(M) Cable Duct / Conduit DWC Pipe : Cable duct/ cable tray of appropriate size from solar panel to inverter/ transformer and cable duct made from PCC etc incl MS plates duct cover 6 mm thick (plain orchequered) channels square cut or notched ( ordinary & counter sunk) forming holes without any attachment complete all as spd and directed.Note: (a) There should be provision of vertical separation between power and control cable duct. (b) Cable ductshall be provided as per approved drg . 25 Supply, installation testing and commissioning of outdoor type step up transformer Inverter duty type low losses of 1 MVA, 0.800/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/delta (Δ/Δ) complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5% in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 26 HV Bushing 33 KV and LV Cable Box suitable for chumathang area of Alt 4200 m along with necessary bus bars with adaptor box suitable for terminating incoming cables from inverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay trip contact and shut off valves. (ii) PRVRelay Trip (iii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iv) Winding temperature indicator with alarm and trip contacts (v) Marshalling box 200 TB (MK) -03 Nos (6 No of terminal , 3 phase primary and 3 phase secondary, Bolted or plu in type terminal, cable entry 3X 50 sqmm (primary) and 3 X 120 sqmm (secondary) cable ties, clips or trays ) (vi) Magnetic oil level gauge. (vii) Pressure release valve (PRV) with trip contacts.(viii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (ix) Oil level indicator with minimum level marking.(x) Thermometer pockets with thermometer. (xi) Silica gel breather (xii) Air Release plug. (xiii) Lifting Lugs (xiv) Earthing terminals (xv) Bi-directional Rollers (xvi) Anodized aluminum rating and diagram plate. (xvii) Off load Tap changer including indoor remote control panel. (xviii) Top filter valve (xix) Including transformer platform as per OEM recommendation is deemed to be included in quoted rates.Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM recommendation is deemed to be included in quoted rates (ii) Rates quoted is inclusive of all control cables of suitable size and core(as per manufacturer recommendations) from buchholz relay, PRV, OTI & WTI of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The step up transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 27 Supply, installation testing and commissioning of outdoor type distribution low losses as per Level II part I (IS:1180) of 1.25 MVA, 0.415/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/star (Δ/Υ) (complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5 % in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 28 HV bushing and LV Cable Box along with necessary bus bars with adaptor box suitable for terminating incoming cables frominverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay with alarm and trip contact and shut off valves. (ii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iii) Winding temperature indicator with alarm and trip contacts (iv) Marshalling box 200 TB (MK) -03 Nos (v) Magnetic oil level gauge. (vi) Pressure release valve (PRV) with trip contacts. (vii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (viii) Oil level indicator with minimum level marking. (ix) Thermometer pockets with thermometer. (x) Silica gel breather (xi) Air Release plug. (xii) Lifting Lugs (xiii) Earthing terminals (xiv) Bi-directional Rollers (xv) Anodized aluminum rating and diagram plate. (xvi) Off load Tap changer. (xvii) Top filter valve (xviii) Differential relay protection for power transformer Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM design is deemed to be included in quoted rates .(ii) Rates quoted is inclusive of all control cables of suitablesize (as per manufacturer recommendations) from different relays buchholz relay of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 29 Supply, installatioon , testing and commissiooning of factory made outdoor type 4 Way 2x630 Amp SF6 + 2x630Amp LBS out door type 11 KV Ringmain Unit with Space Heater at Altitude 4200m, 630 Amps IAC 20 KA for 3 sec suitable for solar power system confirming to relevant IS/IEC, LSC 2B having following specification and comprising of following:- (i) Electrolytic copper bus bars, droppers and bus bar should be insulated with full system voltage sleeves. Each SF6 breaker shall comprise of following 30 (ii) Trolly mounted vaccum circuit breaker as per IEC-62271-100 SF6 circuit breaker should have three Nos resin encapsulated vaccum bottles.(iii) Motorized spring charging mechanism 230V AC 50 Hz with integral spring charging handle for manual spring charging. (iv) Cast resin current transformer 11KV, 200/1-1A, Core-I: class 1.0, 5VA, core2:5P10,5VA.Bushing shall be of 11 KV (v) Cast resin potential transformer 11KV/√3/110V, 50VA, class 0.5Cl 3P, bushing shall be 11KV KV and HT fuse at the primary end and 4P MCB at secondary end of PT. (vi) Accessoories like local/remote switch, breaker control switch (T-N-C) space heater with thermostat, DC and AC control circuit through MCB, indicating lamps for RYB, spring charge, DC supply healthy, breaker ON/OFF , breaker in SERVICE/TEST. (vii) Multifunction meter with RS 485 port , on MODBUS Protocol. (viii) Digital ammeter and digital voltmeter. (ix) Master trip relay-01 No and Aux relay TCS, DC Fail, OC & E/F (x) Comprehensive numarical protection relay on MODBUS protocol compatiable for directional and non directional O/C, E/F, U/V, O/V protection, Pressure switch or gas density monito, Frequency relay, Breaker failure protectionTransfomer protection Bucholz protection, PRV,Differential protection, OTI, WTI Relay and panel should have following additional facilities:- (xi) Trip Ckt supervision, AC fail, DC fail (xii) Disturbance recorder. (xiii) Event log with date and time (xiv) Measurment and control feature (xv) Fully internal arc type tested. (xvi) SF6 bottles should be epoxy encapsulated. (xvii) Racking in/out, manual closing/tripping of CB with compartment door closed. (xviii) Breaker shall be provided with following contacts:- (xix) Auxilary switch with 6 No + 6 NC mounted on the draw out portion of the switchgear. (xx) Position switch with 3 NO + 1NC contacts for eachposition in SERVICE and TEST.(xxi) 16 window annunciater with hooter/alarm for OC,SC,OV,UV,TCS,DC Fail, AC Fail OTI,WTI,PRV,Bucholz, Differential, OF, UF, Gas density low, Breaker failure protection 31 Material and Labour for Earthing complete with GI earthplate electrode 600mm x 600mm and not less than 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to GI strip of size 32x6mm by means of bolts, nuts, check nuts and washers of GI/steel all as shown in electric plate No 3 connected to equipmentscomplete and including char coal dust & salt filling in alternate layers (each layer shall be 15 cm thick)and GI protection pipe, medium grade 40mm dia and GI watering pipe 20mm, medium grade with funnel and wire mesh, 40mm thick pre-cast RCC, M-15 (nominal mix) cover reinforced with XPM weight not less than 4kg/sqm with suitable handle of 6mm dia MS bar and angle iron 40 x 40 x 3mm frame for cover, PCC M-15 (nominal mix) pit, excavation and earth work in any type of soil and connectedcomplete all as specified and directed. 32 Material and Labour for earthing complete with and including copper earth plate electrode 600 mm x 600 mm x 3.15 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected to copper trip earth lead wire 25x6 mm dia by means of nuts, bolts, checknuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SI Part-I. 33 Material and Labour for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr belowground level connecting to galvanisedearth lead wire 4mm dia by means of bolts,check nuts and washers and earth lead protected by provision of GI pipe light grade 15mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 KG/Sqm) and frame of angle iron 25 X 25 X 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, connecting to test pointwith fixing arrangement, funnel, wire mesh and earth work in hard/dense soil,returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3all as specified and testing on completion. Note :- Cost of earth lead upto 7.5 mtr and GI 15mm bore pipe is deemed to be included in unit rate. 34 Supply, installation, testing and commissioning of factory made, DG disribution cum DG syncronization panel of suitable size, outdoor type made out of CRCA sheet 3.15 mm thick with partition of 1.6 mm, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system,comprising of following :- (a)Distribution panel with ACB 2500Amp microprocessor release operation type, 415 Volt 50 KA 1 Nos 2500 Amp ACB (b) DG Synchronizing panel- DG Sync Panel with double busbars required for sync 3 nos 400 KVA DG set after Sync Power fed to 2500 Amp Distribution Panel (c)Control Ckt require for DG Sync With PV System, Logic of this control ckt : DG 1, 400 KVA on all time with minimum 30% load and when load increase 80% DG2 400 KVAstart and so on for all 3rd Nos 400 KVA DG) Note: DG syncronization panel shall be provided as per approved SLDcomplete all as specified and directed.. 35 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1.9/3.3 KVgrade, cross-sectional area 400 Sqmm 3 core for solar ACB panel to inverter duty transformercomplete all as specified and directed. 36 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size400 Sqmmcomplete all as specified and directed. 37 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 Sqmm 3.5 corecomplete all as specified and directed. 38 Material and Labourfor Sand cushing to under ground cable, provided with 8 cms thick layer before laying the cable and 15 cm thick after laying and streching the calbe complete all as specified and directed. 39 Supply and laying unreinforced precast concrete cable cover on the cable in the trench,classl LV, Type-I, flat size 250mm X150mmX50mm(1100 volts LT cable)complete all as specified and directed. 40 Supply and laying Unreinforced precastconcrete cable coveron the cable in the trench , class HV, Type-I, flat size 300mm X180mmX50mm (for 11KV HT cable)complete all as specified and directed. 41 Material and Labour for Solar HT Generation meter AC three phase, multifunction net meter of accuracy class 0.5s, rated voltage 110 V Ph-Ph or 3 X 63.5 V Ph-N, voltage range + 15% to - 30% of rated voltage, basic current 1 Amps or 5 Amps, maximum continuous current 2 times (200%) of basic current , starting current 0.1% of basic current, frequency 50 Hz and operating frequency range 47.5 to 50.5 Hz , IP 65 protection, Protection: over voltage, over current, over/ under grid frequency, over temperature, short circuit. with optical & RS232 port, backlit LCD display, (measures import kWh, kVAh, Export kWh, kVAh , Net kWh, kVAh, V,I, kW, 6 month history of energy, load survey, tamper detection & logging, power On/Off events, instantaneous parameters of rating -/5A with display in absence of powercomplete all as specified and directed. 42 Shifting of DG set of capacity 3 x 400 KVA from location Upper and lower chumathang (Upto 2 Km) near to SPV plant location with all connected items including installation, connection with cable, making of suitable size as per existing 3 Nos PCC plateform of 400 KVA DG set all as per specified and directed 43 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 630 Sqmm 3.5 corecomplete all as specified and directed. 44 Material and Labour for Rolling and consolidation formation surface in cuttingto required camber and gradient with 8 to 12 tonne power roller complete all as specified and directed. 45 Material and Labour for soiling (or Sub Base) 200mm thick (Spread thickness) with broken boulders or quarred stone interstices filled, surface formed and surface formed and rolled and consolidated torequired gradient and camber with 8 to 12 tonne power roller, complete all as specified and directed. 46 Material and Labour for cement concrete work in pavement/hardstanding of flexural strength 40 kg/sqcm in field using 400 kg of cement per Cum for thickness of concrete 20 cm including brooming the surface complete all as specified and directed. 47 Material and Labour for forming contraction (Dummy) joints 80mm deepx 10mm wide filled with sealing compound grade B complete all as specified and directed. 48 Material and Labour for forming 20mm thick expansiion joints filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade B for 200mm thickness of concrete slab complete all as specified and directed. 49 Material and Labour for 150mm thick (compacted thickness) WMM in two equal layers 75mm thick each layer with coarse aggregates of lime stone, sand stone flint or quartizite of grading 2 (63 to 40mm size) spread, rolled and consolidated to required gradient and camber with 8 to 12 tonne power roller complete all as specified and directed. 50 Material and Labour for Cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundation filling and mass concretecomplete all as specified and directed. 51 Material and Labour for Cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in benching, coping around poles (aove GL) etc including weathering slightly rounded or chamfered angles and fair finshing the exposed surfaces or concrete using extra cement cmplete including necessary form workcomplete all as specified and directed. 52 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity750 KVA, Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ C including platform as per OEM recommendation is deemed to be included in quoted rates (For lower Chumathang) 53 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity400 KVA,Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ Cincluding platform as per OEM recommendationis deemed to be included in quoted rates (For additional pocket & Upper chumathang)complete all as specified and directed. 54 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-55 (11 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.(For two/ four pole structure) Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely.complete all as specified and directed. 55 Material and Labour for Switch air break gang opertated tripple pole mechanically operated from ground level mounted, outdoor type suitable for vertical instatllation single break provided with locking arrangement for operating handle with lock consisting of mild steel channelHT post top insulator copper alloy high pressure assembly 33 KV grade complete with all accessoriescomplete all as specified and directed. 56 Supply & fixing lightning arrestor, high tension, polymer type gapless complete with all fitting transmission class, of capacity 33 kilo voltscomplete all as specified and directed. 57 Material and Labour forCross arms, bracing , supports, clamps and aback plates ,fabricated out of structural steel sections incuding nuts, bolts,washers,welding,bending cold or hot, drilling holes for bolts in any shape or size as indicated or coat of red oxide zinx chrome primer, one under coat and one finshing coat of aluminium paint complete all as specified. 58 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 185 Sqmm 3 corecomplete all as specified and directed. 59 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 120 Sqmm 3 corecomplete all as specified and directed. 60 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size120 sqmm to 185 sqmmcompleted all as specified and directed. 61 Material and Labour for ACSR conductor for the provision of HT OH lineof sizes,3 of 6/1X3.0 (Ferret), 3 of 6/ 1x2.59 ( weasel) completed all as specified and directed. 62 Material and Labour for galvanised steel wire of4 mm dia with hooks stretching kinks and bends completed all as specified and directed. 63 Anticlimbing devices spikes type fabricated out of MS bars (round square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and shown on drawings. 64 Supply and fixing pin type 10 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of pin insulator completed all as specified and directed. 65 Supply and fixing disc type 90 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of disc insulator completed all as specified and directed. 66 Supply and fixing of Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letter, figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of approved size, for HT,25x20cm sizecomplete all as specified and directed. 67 Material and Labour for Galvanised steel tubing light grade 80 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 68 Material and Labour for Galvanised steel tubing light grade 100 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 69 Material and Labour for stay assembly complete using stay rod of 20 mm dia complete with accessories as shown in electric plate no 1 of SSR-2009 Part -I complete all as specified and directed by Engr-in-Charge Note: (Unit rate quoted by contractor herein before also includes earth work and PCC work ,Loop type insulator ,stay clamps ,nuts ,bolts ,washers and concretecomplete all as specified and directed. 70 Material and Labour for galvanised stay strand, size 7/4 mmcomplete all as specified and directed. 71 Supply and fixing of loop type porcelain vitreous white ,brown or green insulator large size with overall dimensions 90x140 mm,clearance of hole 25.5 mm complete all as specified and directed 72 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2200 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 73 Under composion of following.(LT panel No-01 Lower Chumathag)(i)ACB 415 V, 4 pole, 1600 Amp, 50 KA -01 No (Incoming)(ii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel (iii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel(iv) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 2500 Amps duly moounted on porcelain insulators -01 Set (v) Digital amp meter 3 ph programmeable type with suitable2500 Amps -01 Set (vi)Digital volt meter 3 ph programmeable type with suitable0- 500 volts -01 Set (vii) LED phase indicator (RYB )-01 Set 74 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 75 Under composion of following. (LT Panel No-2 upper chumathang)(i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming cum outgoing) (ii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1200 Amps duly moounted on porcelain insulators -01 Set(iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set(v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 76 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following. (LT Panel No-3 upper chumathang additional pocket) 77 (i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming)(ii) MCCB 415 V, 4 pole, 200 Amp, 25 KA -1 No (Out Going), MCCB 415 V, 4 pole, 400 Amp, 36 KA -1 No (Out Going) MCCB 415 V, 4 pole, 100 Amp, 25 KA -1 No (Out Going)(iii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1250 Amps duly moounted on porcelain insulators -01 Set (iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set (v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 78 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 Sqmm 3.5 core complete all as specified anddirected 79 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 Sqmm 3.5 core complete all as specified anddirected 80 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 Sqmm 3.5 core complete all as specified anddirected 81 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 2 core complete all as specified anddirected 82 Supply and fixing of LED Street light of 70 Watt , IP66 power coated pressure die cast aluminium housing with high efficiency LED as lighting source and toughened glass complete all as specified anddirected 83 Supply and install LT panel box outdoor type weather & vermin proofsuitable for single phase 230 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 100 Amp insulated with phase indicator incl angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following.(For Street light)(i) MCB SPN 6-32 Amps, 230V, 10 KA -01 No (Incoming)(ii) MCB SP 6-10 Amps, 230V, 10 KA -02 No (outcoming)(iii) Bus bar chamber with and including aluminium strip ( 2 Nos) suitable for 100 Amps duly moounted on porcelain insulators -01 Set (iv) LED phase indicator (RYB )-01 Set 84 Supply and fixing GI bracket 1.2 m long made out of GI pipe 40mm dia mediam grade with necessary clamp for fixing nut and bolts and connection complete all as specified anddirected 85 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-31 (09 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely. 86 Supply and fixing of 2.5 sqmm copper conductor cable for street light connection from junction box to street light at pole all as specified and directed by Engr-in-charge 87 Supply and fixing of junction box made out of PVC box with necessary clamps for fixing busbar with MCB SP 6 Amps and necessary connection from street light to junction box with 2.5 sqmm x 3C copper conductor cable complete all as specified anddirected 88 Material and Labour for Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in bed to drain pipes including packing under and haunching completely surrounding pipes with concrete after they laid and tested for 150 mm bore NP 2 pipe, complete all as specified and directed. 89 Material and Labour forM&L for Reinforced concrete pipes,class NP2,dia 150 mmlaid and jointed complete with collars complete all as specified and directed. 90 Material and Labour for PCC 1:2:4 Type B1 using 20 mm garded stone agg as in coping including weathering slightly rounded or chamfered angles and throating complete all as specified and directed. 91 Supply onlyliquid water proofing compoundcomplete all as specified and directed. 92 Material and Labour forTMT bars 10mm dia and over , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed not less than 0.9mm dia, or securing with clips, rungs, handles completeall as specified and directed. 93 Material and Labour forprecast cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in manhole coverslabsincluding necessary formworks set in cement mortar 1:4 complete all as specified and directed. 94 Material and Labour for cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in surface channel and inside drains of manhole complete all as specified and directed. 95 Material and Labour for Mild steel rungs and handle made to shape out of 16mm dia round barsconforming to Fe-290grade E-165including fixing/embedding in concrete /masonrypainted with two coats of bituminous paint complete all as specified and directed. 96 Extra forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc complete all as specified and directed. 97 Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work not exc 200mm thick (horizontal or sloping) for flat fair finished surfaces complete all as specified and directed. 98 Material and Labour for construction of septic tank for 10 users designed to carry sewage and sewage water, excavation in any type of soil, PCC 1:2:4 type B-2 using 40mm graded crushed stone aggregates in foundation, precast cement concrete block masonry wall, RCC cover slab complete all as specified and directed and shown on drawing. 99 Material and Labour for construction of soakage well with excavation in any type of soil complete all as specifiedand directed and shown on drawing. 100 Material and Labour for MS work as in posts and struts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 Supply only chain link MS galvanised fencing any size or type complete all as specified anddirectedNote : weight of chain link fencing shall be checked by BOO detailed by GE. 102 Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards rails straining bolts etc including provision of binding wire complete all as specified and directed. 103 Material and Labour for prepration of new or previously untreated steel surface & priming with red oxide primer and applying two coats of synthetic enamel paint of any description over 10cm width or girth not otherwise described complete all as specified and directed. 104 Material and Labour for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 105 Material and Labour for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 22.5cm longand diameter of neck 11 to 15mm complete all as specified and directed. 106 Material and Labour for construction of steel gate 5.5m wide and 3m high with RCC pillars including excavation and earth work and all other relevant works complete all as specified and directed. 107 Excavation over area not exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed. 108 Excavation in trenches, n exc 1.5 mtr wide and n exc 1.5 mtr in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n exc 10 Sqm on plan and n exc 1.5 mtr in depth and getting out inhard/dense soil. Complete all specifed and directed. 109 All as per Srl No. 94. above but exc 1.5 m or part there ofin depth beyond the first 1.5m complete all as specified anddirected 110 Excavation in post holes (or similar holes) each not exc 0.5 Cum getting out returning filling and ramming earth or broken rubble mixed with earth around in layers not exc 25cm watering and removing surplus soil to a distance not exc 50 and making good surface in hard/dense soil complete all as specified and directed. 111 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed . 112 Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. 113 Removing excavated rocks material from site n exc. 50 m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified anddirected
Contract Date: Jun 20, 2026 Contract Value : 6.14 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
7.
Drinking Water Supply and Sanitation #10709044 Price Bid
Purchase Of High-Performance Liquid Chromatography ( Hplc ) For Wazirabad Laboratory , Hplc For Chemical Section Wazirabadwith The Specification Below : • System Should Be Supplied With Pumps, Detectors, Sample Tray, Columns, Valves Etc Required To Run The Complete Protocol Used For The Water Sample. • System Should Be Comprehensive And Flexible • Isocratic System, Binary Gradient System, Quaternary Gradient System Should Be Available. • Should Have An Option Of Detection Capabilities Include Dad, Uv / Vis, Fl, Ri And Elsd. • Stable And Reliable • Advanced Usb Chip And Optoelectronic Isolation Technology Ensuring Stable Communication. • System Should Be Simple And Safe • Powerful Software Makes It Simple To Control, Capture, Manage And Analyse • Real-Time Pressure Display, Maximum And Minimum Pressure Warning Ensure The Security Product Parameters Technical Parameters: High Pressure Constant Flow Pump 2 Set Flow Rate Range: 0.001Ml / Min-10.000Ml / Min, Flow Accuracy: =±0.2% Flow Precision: Rsd=0.06%, Maximum Pressure: 45Mpa Pressure Accuracy: =±3.0% , Pressure Pulsation: =0.1Mpa Uv / Vis Detector Linear: 2.0Au , Wavelength Range: 190-700Nm Wavelength Repeatability: =0.1Nm, Wavelength Accuracy: =±1.0Nm Band Width: 8Nm, Response Time: 0.0S-5S Baseline Noise: =±0.5×10-5Au, Drift: =1.0×10-4Au / H Path Length: 10 Mm ( Analytical Cell ) Data-Processing Workstation Internal And External Standard Calculation Methods Automatically Displays, Prints, Exports And Starts Other Programs After The Completion Of A Pmeasurement. Comply With The Requirements Of The 21 Cfr Part 11 Directive Of The Fda System Kits 1 Set Power Supply Ac110 / 220V±10%, 50 / 60Hz Optional Accessory: Should Be Available With The Supplier And Price Should Be Quoted As Optional For Individual Part- Column Oven, Autosampler, Degasser, Diode Array Detector, Refractive Index Detector, Evaporative Light Scattering Detector, Fluorescence Detector
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
8.
Communications and Information Technology  #10603184 Price Bid
Supply Of Electronic Components - Wingz , Electronic Components , Diode Switching 50V Sot-143 , Cap Cer 1Uf 10V X5r 0402 , Cap Cer 100Pf 50V Np0 0402 , Cga1a2x7r1a103m030ba , Cap Cer , 56Pf 50V , 10% , C0g , 0402 , Cap Cer 0 . 22Uf 6 . 3V 20% X5r 0201 , Cap Cer 0 . 22Uf 6 . 3V 10% X5r 0402 , Cap Cer 0201 25Vdc 0 . 47Pf C0g Tol 0 . 05Pf , Cap Cer 16Pf 50V C0g/Npo 0402 , Cap Cer 4 . 7Pf 50V C0g/Np0 0603 , Cap Cer , 18Pf 50V , 1% , C0g , 0402 , Cap Cer 22Uf 10V Jb 0805 , Cap Cer , 8200Pf 25V , 5% , X7r , 0402 , Cap Cer 0 . 22Uf 10V X5r 0402 , Cap Cer 22Uf 6 . 3V X5r 0603 , Cap Cer 2 . 2Uf 25V X5r 0603 , Ap Cer 4 . 7Uf 10V X5r 0603 , Cap Cer 1000Pf 50V C0g/Np0 0402 , Cap Cer 1000Pf 50V C0g/Np0 0402 , Cap Cer , 100Uf 6 . 3V , 20% , 0805 , Cap Cer 0 . 1Uf 16V X7r 0402 , Cap Cer 33Pf 50V C0g/Np0 0402 , Cap Cer 12Pf 50V C0g/Np0 0402 , Umk105cg2r2cv-F , Cap Cer 0 . 2Uf , 50V , C0g , 0402 , Cap Cer 22Pf 50V C0g/Np0 0402 , Cap Cer 22Uf 6 . 3V X5r 0603 , Cap Cer 0 . 68Uf 6 . 3V X5r 0402 , Cap Cer , 47Uf 10V , 20% , X5r , 0805 , Cap Cer , 10Uf 10V , 20% , X5r , 0603 , Mlcc - Smd/Smt 0402 560Pf 50Volts X7r 10% , Mlcc - Smd/Smt 0201 0 . 47Uf 6 . 3Volts , Led Red , Sgl 20Ma , 0603 , Led Red Grn Dual , 20Ma , 0603 , Schottky Diode , 1A , 20V , Led , Tri Color Red Grn Blue , Diode Sch 30V 200Ma -- Sod323 , Led Red , Sgl 20Ma , 0603 , Schottky Diode , 1A , 40V , Diode Array Schottky 45V To277a , Esd Protection Diode Array For Usb-Otg , Schottky Diode , 1A , 40V , Tvs Diode 15V 1005 , Schottky Diode , 1A , 40V , Schottky Diode , 10A , 30V , Con 1X5 Usb_Micro_Ab_Receptacle Ra Smt 0 . 65Mm Sp 105H Au , Usb Type-A Double Deck Connector , Usim Connector Sim Card For Uc-20 Module , Memory Card Connectors Microsd Rev Mount Push-Push W/Switch , Conn Fpc Bottom 40Pos 0 . 50Mm R/A , Con 19 Hdmi_Type_A Ra Skt 20Mil Sp 248H Au , Conn Ffc Fpc Top 6Pos 1 . 00Mm R/A , Ffc & Fpc Connectors 15P Side Smt Zif Lower Contact , Audio Jack , Smt , 6P , Ind Fer Bead , 33Ohm , 3A , 25% , 0603 , Ind , 2 . 2Uh , 1 . 4A , 20% , Smt , Ind Fer Bead , 120Ohm , 2A , 25% , 0603 , Ind 4 . 7Uh , 2 . 15A , 25% , Smt , Ind Chk , 90 Ohm , 330Ma , 25% , 0805 , Ind 10Uh , 3A , 20% , Smt , Ind 2 . 2Uh , 1 . 7A , 30% , Smt , Ind Fer Bead , 4 . 7Nh , 0 . 3A , 0402 , Ind Rf 1Nh , 300Ma , 0402 , Ind Rf 2Nh , 300Ma , 0402 , Ind , 1Uh , 11A , 20% , Smt , Ind 3 . 3Uh , 12A , 20% , Mosfet 12V 5 . 1A 2 . 5W 35 Mohms @ 4 . 5V , Mosfet P-Ch 30V 4 . 3A Sot23 , Mosfet N-Ch 60V 0 . 115A Sot-23-3 , Trans Npn 40V 0 . 2A Smd Sot23-3 , Bipolar Transistors - Pre-Biased Npn Digital Transtr W/Built In Resistors , Res , 523K , 1/10W , 1% , 0402 , Res , 1 . 6K , 1/10W , 1% , 0402 , Res , 200R , 1/8W , 1% , 0402 , Res 2 . 2M Ohm 1% 1/16W 0402 , Res , 240R , 1/10W , 1% , 0402 , Res , 10K , 1/8W , 0402 , 1% , Res , 12 . 7K , 1/10W , 1% , 0402 , Res , 470R , 1/10W , 1% , 0402 , Res 1K , 1/8W , 1% , 0402 , Res , 24K , 1/10W , 1% , 0402 , Res Smd 124K Ohm 1% 1/16W 0402 , Res 2 . 37K , 1/10W , 1% , 0402 , Res , 4 . 7K , 1/16W , 1% , 0402 , Res 22 . 1K Ohm 1% 1/10W 0603 , Res 200K , 1/10W , 1% , 0402 , Res Smd 1M Ohm 1% 1/16W 0402 , Res , 15K , 1/10W , 1% , 0402 , Res , 47K , 1/10W , 1% , 0402 , Res , 100R , 1/10W , 1% , 0402 , Res , 27K , 1/10W , 1% , 0402 , Res , 33K , 1/10W , 1% , 0402 , Res 2 . 2K , 0 . 063W , 1% , 0402 , Res 4 . 99K , 1/10W , 1% , 0402 , Res 0Ohm , 1A , 0402 , Res 30R , 1/10W , 1% , 0402 , Res , 12K , 1/10W , 1% , 0402 , Res 0 . 02R , 1/5W , 1% , 0603 , Res , 51K , 1/10W , 1% , 0402 , Res , 22R , 1/10W/1% , 0402 , Res , 56K , 1/10W , 1% , 0402 , Res Smd 3 . 9K Ohm 1% , Res Smd 10 Ohm 1% 1/16W 0402 , Res , 100K , 1/10W , 1% , 0402 , Res , 270R , 1/10W , 1% , 0402 , Res 0 . 05R , 0 . 33W , 1% , 0603 , Res , 68K , 1/10W/1% , 0402 , Res 0 . 1R , 1/2W , 1% , 0805 , Res , 6 . 04K , 1/10W , 1% , 0402 , Res , 191R , 1/10W , 1% , 0402 , Erj-3Ekf3303v , Res , 412 Kohms , 0 . 5% , 0603 , Thick Film Resistors - Smd 3 Ohm 1% , Res Array 8 , 33R , 5% , Convex , Rnet Bus , 10K , 5% , Smt , 10P , Sw Spst Dip 8 Smt , Ldo Voltage Regulators 1A Ldo 2 . 5V Fixed 300Ma Enable , Ldo Voltage Regulators 1A Ldo 3 . 3V Fixed 300Ma Enable , Ldo Voltage Regulators 1A Ldo Regulator , Ic Power Management Automotive 2 . 8-4 . 5V Qfn56 , I . Mx6 Application Processor Dual Lite , Ic Mem Ddr3 Sdram 2Gb 128Mx16 1 . 35V Fbga96 , Ic Buf Ts 0 . 9-3 . 6V , 8 Gb , Emmc Mod , Bga-153P , Ic Mem Serial Flash 32Mbit 2 . 7-3 . 6V So8w , Ic Hdmi Transmitter 38Tssop , Dc/Dc Bosst Converted , Power Switch Ics - Power Distribution 12V 1 . 1A . 357Watt , Ic Vxltr 1 Bit Dual-Supply 0 . 9-4 . 5V 613Af , Interface - Codecs Audio Codec , Ldo Voltage Regulators 1A Adj Ldo Fixed Reg 1 . 2V 150Mv 300Ma , Ic Battery Charger Solar 12Msop , Ethernet Ics Gigabit Ethernet Transceiver With Rgmii , Ic Buf Dual Ts 1 . 65-5 . 5V Ssop8 , Ic Xcvr Usb To Uart Ctlr 3 . 3-5 . 25V Qfn32 , Ic Xcvr Can Hs 5V So8 , Usb Switch Ics Dual Switch 125Mohms 1 . 5A , Usb Interface Ic Usb 2 . 0 High Speed 4 Port Hub Contrl , Ic Sensor Ambient Light 6Chipled , Accelerometers Ultra-Compact High Performance 3D Accel , Board Mount Humidity Sensors Humid & Temp Sensor , Ec25e Cellular Module Lte With Gps/Glonass , Ic Reg Ldo Adj 3A To252-5 , Tvs Diode 6Vwm 13Vc Sc706 , Rf System On A Chip - Soc Ic Rf Zigbee 802 . 15 . 4 Soc , Rf Front End 2 . 4 Ghz Range Extender Up To X7 , Wifi / 802 . 11 Modules Tiwi-Ble Module Wlan , Bt , Ble , Ant , Ic Reg Buck Adj 4A Sync 8Sop , 5A , 18V Adaptive Ccm/Cot Step-Down Converter , Xtal 24Mhz -- 3 . 2X2 . 5Mm Smt Crystals 24Mhz 10Ppm 9Pf -40C +85C , Crystals 32 . 768Khz 20Ppm 12 . 5Pf -40C +85C , Crystals 25Mhz 10Ppm 18Pf -20C +85C , Crystals 24Mhz 18Pf Hc49s Smd , Crystals 32Mhz 10Ppm 10Pf -40C +85C , Standard Clock Oscillators 32 . 768Khz R2r Lvcmos -40 To 85C 100Ppm , Tft Displays & Accessories 7 Tft W/Capacitive Touch Panel 800X480 , Modular Connectors / Ethernet Connectors Rj45 Connector
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 13
9.
Educational and Research Institute #10510174 Price Bid
Tender For Tinkering Lab Equipments Purchase And Lab Installation , Electronics Development , Arduinouno Or Equivalent , Arduino Nano Or Equivalent , Arduino Mega Or Equivalent , Raspberrypi3 Model B+ , Breadboards &Mini Breadboard , General Purpose Solderable Board , General Purpose Solderable Board , Berg Strips , 16X2 Lcd Display , Usb Cables , Usb Cables , Battery , Resistor Kit , Capacitor Kit , Linear Voltage Regulator , Water Pump Module , Piezoelectric Plate , 8*8 Led Matrix Module , Bluetooth Module , 7 Segment Led Display , Gsm , Gps , Laser Diode Emitter , Ldr Module , Keypad , Joystick , Active Buzzer , Motor Drive Module , Sound Playback Module , Dcplastic Gear Motor With Wheel , Node Mcu , Wemosd1r2 , Vibrating Motor , Alligator Connectors , Battery Clips With Dc Jack , Hook-Up Wires , Jumper Cable , Rgb Leds , Rgb Leds ( Red ) , Rgb Leds ( Green ) , Rgb Leds ( Blue ) , Rgb Leds ( Yellow ) , Rgb Leds ( White ) , Timer Ic-Lm 555 , Atmega16u2 , Diodes And Transistors Kit , Button Switch Set , Capacitative Touch Switch Module , Ir Sensors, Obstacle Avoider Sensormodule , Internet Of Things & Sensors , Triple Axis Magnetometer , Humidity Sensor , Mq Series , Ir Transmitter / Receiver , Ultrasonic Sensor Module Hc-Sr-04 Or Compatible , Triple Axis Accelerometer , Pir Motion Detector Module , Pulse Rate Heart Sensor , Rely Module , Big Sound Microphone Module , Soil Moisture Sensor Module , Touch Sensor , Metal Touch Sensor Module , Rain Drop Sensor , Flex Sensor , Temperature Sensor , Force Pressure Sensor , Colour Recognition Sensor , Water Flow Sensor , Sound Sensor , Ir Sensor Array Module For Line Following , Power Bank , Rfid Reader Tags , Rfmodulestx & Rx 315 Mhz Ask , Robotics , Stepper Motor With Driver Board , Dc Motor , Servo Motors , 150 Rpm Bo Motor , L298p Motor Driver , Servo Motor Tester , Diy Kit , Robotics Diy Kit , Mechanical ( Modular ) Construction Kit , Stem Learning / Application Kit , Drone Kit , Aerospace Kit , Automobile Kit , Bio Medical Kit , Agri-Tech Kit , Water / Sanitation Kit , Bio Tech Kit , Other Potential Stem Application Kit , Package 2 Rapid Prototyping Tools , 3D Printer Kit And Tools , Dedicated Ups / Power Back Up , Filament For 3D Printer , Filament Storage Box , Set Of Arts & Crafts Accessories- E.G. -Stationary Items And Basic Prototyping Material--Cardboard , Set Of Arts & Crafts Accessories- E.G. -Stationary Items And Basic Prototyping Material--Foam Core Boards , Set Of Arts & Crafts Accessories- E.G. -Stationary Items And Basic Prototyping Material- 20 M Spool Of Thick Strings Various Colours , Set Of Arts & Crafts Accessories- E.G. -Stationary Items And Basic Prototyping Material- Rubber Band , Set Of Arts & Crafts Accessories- E.G. -Stationary Items And Basic Prototyping Material- Popsicle Sticks , Set Of Arts & Crafts Accessories- E.G. -Stationary Items And Basic Prototyping Material- Wood Glue- 500 Ml , Package 3: Mechanical, Electrical And Measurement Tools , Hacksaw Frame , Hacksaw Blades , Mini Hacksaw Frame , Mini Hacksaw Blades , Pliers: 4.5 Inch Size--External Straight , Pliers: 4.5 Inch Size--Nose Circlip Plier , Pliers: 4.5 Inch Size--Long Nose Plier , Pliers: 4.5 Inch Size--Combination Mini Plier , Pliers: 4.5 Inch Size--Wire Stripping Pliers , Pliers: 4.5 Inch Size--Bent Nose Plier , Pliers: 4.5 Inch Size--Needle Nose Pliers , Tweezer Set , Ball Pin Hammer , Steel Shaft Claw Hammer , C- Clamp , Allen Key Set , Drill Machine Set , Drilling Workstation , Spanner Set , Vice Normal , Precision Screw Driver Set , Wrench , Wire Strippers , Screwdriver , Cordless Rotary Multi-Tool Set , Air Blower , Drill Bit Set , File Set , Mini File Set , Flexible Cutting Mat , Plastic Storage Drawer / Organiser , Pegboard , Electric Tools , Hot Glue Gun , Digital Oscilloscope , Soldering Kit , Adapters , Adapters , Electric Screw Driver Set , Dual Temperature Heat Gun , Soldering Helping Hand , Measurement Tools , Return Measuring Tape , Stainless Steel Rule , Digital Vernier Calliper , Spirit Level , Digital Pen Electric Tester , Digital Multi Meter , Biology Kit , , Diy Papermicroscope , Astronomy Equipment , Telescope, , Textileequipment, Sewing Kit , Package 4 : Power Supply & Accessories And Safety Equipment , Glue Sticks , Nuts And Bolts And Screw , Cable Tie- Pack Of 100 , Sand Paper , Power Strip Adaptors-5M , Bulb Holders , Electric Wires , Usb To Dc Jack Cable , First Aid Kit , Fire Extinguisher ( Handy Units ) , Safety Goggles [ With / With Out Led Torch ] , Safety Glove , Safety Mask , Projector Setup , Lap Top , Projector , Projector Screen , Electronics Development , Power Plug , Plugs , Ac Plug , Mcb 16A Switch , Mcb 20A Switch , Mcb 10A Switch , Elcb , Fan , Tube , Wires , Furniture , Executive Chair , Executive Table , Table , Stool , Chair , Almirah , Painting , Rooms , Door , Windows , Curtains , Window Blinds Curtain
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
10.
Health and Family Welfare #10433257 Price Bid
Supply Of Machine, Equipment And Others , List Of Machine And Equipments , Laproscopic Hd Camera Brand - Karl Storz/Conmed/Olympus Technical Specification Resolution: 1920X1200 Pixes / 1900X1000 Pixes Cable Length: 300 Cm , Ultrasonic Harmonic Scalpel Brand - Johnson Technical Specification Dimensions: (Hxwxd) 5.3 14.5X15.2 Voltage: 100-240 Vac Frequency: 50/60 Hz Rated Current: 3 Amp , Ultrasonic Harmonic Scalpel Brand - Valley Lab Technical Specification Macrobipolar/Bipolar: 473 Khz Sinusoid, 100% Duty Cycle. Seal: 473 Khz Sinusoid Pulsed , Hand Instruments For Laproscopy Brand- Karl Storz/ Olympus Technical Specification I) Veress Needle: It Should Be With Spring Action Blunt Style -12 Cm: 1 No 10 Cm: 1 No 8 Cm: 1 No Ii) Trocar And Cannula:10 Mm: 2 Nos 7 Mm: 1 No. 5 Mm 6 Nos It Should Consists Of Trocar, Cannula With Insufflation And Multifunctional Valve And Must Have Pyramidal Tip. Iii) Reducer/Reduction Sleeve 5 Mm. 1 No Iv) Telescopes: 10 Mm- 0°- 1 Nos -30? - 1 Nos5 Mm-30? 1 Nos Rigid Rod Lens System Provides Good Resolution And The Better Dept Perception. It Should Have Uniform Image Brightness And Autoclavable. The 300 Forward Oblique Angle And Permits For Greater Latitude For Viewing Underlying Areas Under Difficult Anatomical Conditions. V) Suction Cannula: 10 Mm - 1 No 5 Mm -1 Nos Vi) Laparoscopic Scissors: Curved (Monopolar Metzenbaum Dissector 5Mm Diameter): 1 Nos Straight (Bipolar):1 Nosperitoneal Scissor: 1 Nosvii) Unipolar Forceps (Hook & Spatula): 2 Nos Viii) Bipolar Forceps : 2 Nos Ix) Atraumatic Forceps: Maryland Dissector Forceps: : 2 Nos. Fenestrated Forceps: : 2 Nos. X) Needle Holder (Flat Jaw) With Handle : 2Nos Xi) Monopolar Cable (Reusable):1 Nos. Xii) Bipolar Cable (Reusable): 1 Nos Xiii) Allis (Double Row Of Teeth) Grasper: 1 Nosxiv) Aspiration Needle: 1 Nos. Xv) Reducer/ Reduction Sleeve (5Mm): 1 Nos Xvi) Grasping Forceps (Toothed & Rachet 5Mm): 2 Nos Xvii) Laparoscopic Knot Pusher: 1 Nos Xviii) Clip Applicator (Reusable): 5Mm -: 1 Nos : 10 Mm: Ino Xix) Uterine Manipulator: 1 Nos Xx) Clips( Medium & Large) Xxi) Drilling Needle:1 Nos Xxii) Infiltration Needle: 1 Nos Xxiii) Biopsy Forceps (Toothed Punch Biopsy): 1 Nos Xxiv) Myoma Fixation Screw: 2 Nos Xxv) Tissue Morcellator With Base Unit & Accessories: 1 Nos , Dual Wavelenght Laser Brand- Zeiss Technical Specification Laser Type: Diode, Semiconductor Wavelength : 1470Nm+635Nm Max Power: 15 Watts/1470Nm+5Mv/635 Aiming Beam : 635Nm/1, 4Mw Max Or 515Nm/2, 5Mw Max Operation Mode : Continuous Or Modulated Pulsed Time : 0.05Ms-1000Ms Beam Delivery : Sma905 Connector Optic Fiber Compatible : Optic Fibers Having A Core From 200Um To 1000Um, Na=0.22~0.48 Beam Emission Initiation : Footswitch Controller :Microprocessor Display : 10.1 Ips With Touch Panel Medical Approved Cooling :Internal, Air And Thermoelectric Cooling Power Supply Of The Laser: Dc 24V/8.33A From The Separate Ac Power Supply Of Ac Adapter : Single Phase 100-240Va; 50-60Hz, Max 90W Ac Adapterdc 24V/8.33A Medical Approved Laser Dimensions: 27Cm*24,5Cm X 9Cm Laser Weight: 2.75Kg Laser Case Dimensions : 53Cm X 38Cm X 23Cm Weight Of Laser With Cases : 9Kg Environmental Conditions During Work : From +10 To 24°C Degree, Relative Humidity From 30% Up To 60% Cass Of Medical Deviceiib Laser Safety Class 4 Electric Safety Class I Type B Housing Protection Degree Ip20b , Hd Camera Set Brand- Karl Storz/ Olympus Technical Specification (I) Hopkinsa® Forward-Oblique Telescope 30A, Diameter 4 Mm, Length 30 Cm, A Utoclavable, Fiber Optic Light Transmission Incorporated, Color Code Ed :1 Nos (Ii) Telecam C3 : 1 Nos (Iii) Image1 St™ Hx One-Chip Full Hd Camera Head, 50/60 Hz, Fixed Focus, Prog Ressive Scan, Soakable, Gas-And Plasmasterilizable, Focal Length F = 16 Mm, 2 Freely Programmable Camera Head Buttons, For Use With Image1 X-Link Tc301, Tele Pack + And Tp101 : 1 Nos (Iv) Medical Grade Surgical Monitor - Fhd : 1Nos (V) Cold Light Fountain Power Led 175 Scb, With Integrated Karl Storz-Scb, High-Performance Led And One Karl Storz Light Outlet, Power Supply 11-240 Vac, 50/60 Hz Including: 400 A Mains Cord 20090170 Scb Connecti G Cable : 1Nos (Vi) Fiber Optic Light Cable, With Straight Connector, Extremely Heat-Resi Stant, With Safety Lock, Diameter 4. 8 Mm, Length 250 Cm :1 Nos , T U R P Set Brand-Olympus Technical Specification (1) Cystoscope-Urethroscope Sheath, 22 Fr :1 Nos (2) Telescope Bridge, With 1 Lockable Channel, For Use With Cystoscope Sheaths : 1Nos (3) Working Element, E 1 Working Element (Also For Use With Optical Urethrotome) 2 Cutting Loops2 Coagulat Ng Electrodes 2 High Frequency Cords 1 Protection Tube . The Thumb Support Is Movable. In Rest Position Th Electrode Is Inside The Sheath.:1 Nos (4) Resectoscope Sheath, 26 Fr, 1 Nos (5) Schmiedt Visual Obturator, : 1 Nos (6) Cutting Loop Angled, 24/26 Fr., Units Of 6 : 1Nos Ellik Evacuator:1 Nos (7)Urethrotome Sheath, 21 Fr. Urethrotome Sheath And 2 Luer-Lock Cones.:1 Nos (8) Obturator, For Urethrotome Sheath, 21 Fr.1 Nos Sachse Cold Knife, Straight, Not To Be Used With Hf Current This Artic Le Is Only Available In Units Of 6 :1 Nos , Flexible Cystoscope Brand-Olympus Technical Specification Cysto-Urethro-Fiberscope, With Contrapositive Deflection Mechanism, De Flection Of Distal Tip 210°/140, Direction Of View 0°, Angle Of View 10, Working Channel Inner Diameter 7 Fr., Sheath Size 15.5 Fr., Worki G Length 37 ??, Consisting Of: 11272 Cu1 Cystourethro-Fiberscope 2767 A Case 27023 Fe Grasping Forceps 27023 Ze Biopsy Forceps 13242 Xl Lea Age Tester 11025 E Pressure Compensation Cap 27651 B Cleaning Brush 27 14 Y Lueradaptor , Echocardiography Brand-Ge Healthcare/ Philips / Siemens Healthcare/Bpl Technical Specification A) 2D, M-Mode, Colour M-Mode B) Colour Flow Doppler Imaging C) Fully Steerable Pulsed Doppler D) Fully Steerabie Continuous Wave Recall E) Digital Cine Replay Of All Imaging And Doppler Modalities. F) On Screen Cine Storage & Image Recall G) Digital Image Storage And Patient Archive With True Scanner Frame Rates. H) Full Measurement And Analysis Capabilities. Both On Line And Offline Preferable. I) Imaging Frequencies From 1 Mhz To 15 Mhz J) Review Of Stored Ultrasound Images. K) User Adjustable B Colorization Maps, Gain Settings, Colour Doppler Baseline, Angle Correction And Other Important Parameters With Live/Frozen/Archived Images/Loops. , 12 Lead Ecg Machine (Brand - Bpl/Maestros) Technical Specification Electrocardiograph Should Have Capability Of Recording 12-Lead Ecg And Should Have The Following Features: 1. Should Have Simultaneous Acquisition Of 12 Leads 2. Should Have A Display To Preview The Ecg Waveform Before Printing 3. Should Have 7 Inch Or More Display With High Resolution Screen 4. Should Be Compact, Portable And Easy To Operate 5. Should Have Keyboard For Manual Entry Of Patient Data 6. Should Have Provision For Providing Hospital Name On The Printed Record7. Should Work On Li-Ion Battery8. Should Have A Frequency Response Of 0.01-300 Hz 9. Should Have Sampling Frequency Of 15,000 Hz Or More10. The Device Should Weigh Less Than 5.5 Kgs With Battery11. Should Have A Special Arrhythmia Triggered Mode Of Printing12. Should Have Pacemaker Detection Facility 13. Should Be Able To Record On Different Modes Of Sensitivity: 2.5,5,10,20 Mm/Mv & Agc14. Should Have Different Recording Speeds: 5, 10, 12.5, 25 And 50 Mm/Sec15. Should Have Different Filters Available For Smoothing Of Waveform16. Should Have Ac Filter, Emg Filter: 25 Or 35 Or 45 Hz Or Off17. Should Have Anti-Drift Filter18. Should Have Different Print Formats: 3/6/12, 3X4 With Rhythm Leads, 6X2, 12X119. Should Have A Large Storage Of 700 Ecgs Or More20. In Case Of Error In Lead Connections, The Machine Should Display The Change In Color Of Particular Lead.21. Should Be Able Transfer Data Directly In Pdf Format To Usb22. Should Be Able To Printout Records On Thermal Paper As Well Z-Fold23. Should Have Facility Of Printing In Automatic/ Manual/ Rhythm/ R-R Mode Of Printing24. Should Have Facility For Interpretations And Measurements25. Should Provide Detailed Printout Of Patient Data26. Should Have Paper Of Minimum Width Of 210Mm27. Should Have The Capability To Generate Any Number Of Ecg Copies For Distribution28. Should Be Able To Connect To Pc 29. Should Be Able To Operate To A Maximum Of 4 Hours On A Newly Charged Battery30. Should Have Direct External Printer Connectivity31. The Unit Should Be Portable And Should Be Able To Carry With Help Of A Handle.32. The Product Should Be Ce Certified33. The Manufacturer Should Be Iso Certified34. The Device Should Be Provided With Standard Accessories:A) Ecg Cable (Adult)-1 Nob) Gel Bottle- 1 Noc) Chest Electrodes (Set Of 6)- 1 Nod) Limb Electrodes (Set Of 4)- 1 Noe) Z-Fold Paper - 1 Packf) User Manual-1 No , Multipara Patient Monitor(Brand - Drager/Penlon/ Bpl) Technical Specifications For Multipara Monitor 1. Multiparameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,(Massimo),Nibp (Suntech) Temperature.3. Optional Parameter Etco2, Dual Ibp, Agm 4. Should Have12-Inchcolor Lcd Display.5. Should Have Dual Modes Of Operation: Rotary Knob.6. Should Display 7 Waveforms Or More7. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen.8. Ecg: Should Be Able To Monitor Ecg Through 5-Lead Patient Cab Should Have Manual St Analysis Window ,Should Detect 20 Arrhythmias And Generate Alarms. , The Priority Of Arrhythmia Alarms Can Be Configurable, Should Measure Pvc &Pac Should Be Able To Monitor Heart Rate From 10-300 Bpm Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etcshould Have Pacemaker Detection Facility Respiration: Measurement Range Of 0 To 150 Breaths Per Minshould Have Gain Selection: ×0.25, ×1, ×2, ×4 Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S Should Have Apnea Detection Facility Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 10 Spo2: Should Have Massimo Technologyshould Have Measurement Range Of 0~100 % Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph Should Be Able To Select Sat Sec To Avoid False Alarm 11. Nibp: Must Be Of Suntech Medicaltechnology For Clinical-Grade Blood Pressure Measurement Have Auto, Manual, And Stat Modes Of Operation For Nibp. Should Have A Measuring Range Of 0-280 Mmhg Should Have 2 Channels For Temperature Monitoring Should Have Data Storage Capabilities:72 Hours Of Trend Data Storage. , Bp Machine Brand - Pagoda/ Omron/ Platinium/ Dr Trust/Bpl Technical Specification Should Be Able To Measure Blood Pressure And Pulse Rate In Adult As Well As Pediatric Patients. Should Be Based On Oscillometric Measurement Technology, Using Dynamic Linear Deflation Method. Should Have Backlight Lcd Display With Easy To View Readings In Dim Light. Pressuremeasurement Range Should Be 60 To 250Mm Hg Systolic, And 40 To 200Mm Hg Diastolic. Pressure Display Accuracy Of +/- 3 To 5 Mm Hg Pulse Rate Measurement Range Of 40 To 200 Per Minute Pulse Measurement Accuracy Of Within 5% Should Include Ac Adapter (Input Range 100-240V And Output Voltage Dc 6V), Preferably With Rechargeable Battery (3.6V To 4.8V, 1900 To 2400Mah) Cuff (22 To 32 Cm Size) Should Be Supplied With Standard Adult Size Single Button Operation For Start And Stop Functions With Auto-Inflation Of Blood Pressure Cuff. , Ventilator Brand - Drager/Bpl/Medisys Technical Specification 1. The Ventilator Should Be High-Endventilator Suitable For Ventilating To Adult And Pediatric Application. Should Have Advanced Microprocessor Control System With Individual Selection Of Various Ventilation Parameters. 2. The Unit Should Be With Altitude Compensation For Volume And Btps Correction For Monitoring3. The Unit Should Be Of Wall Independent Gas Delivery System. Demonstration Of The Equipment Is A Must Demonstration Of The Equipment Is A Must4. Should Have Facility For Invasive And Non-Invasive Ventilation;5. The Ventilator Should Have 12” Or More Lcd Screen With Touch Facility For Display Of Waveforms. Should Have Brightness Modes Like Day/Night-Mode. The Real Time Display Of All Parameters/Waveforms Should Be Clearly Visible From All Angles6. Should Have Modes Of Ventilation Equipped With Newer Modes Of Ventilation:A) Assist/ Controlb) Volume Control Modes: Vcv, Vc-Simv, Plvc) Pressure Control Modes: Pcv, Pc-Simv, Bi-Level, Bilevel-St, Pc-Aprvd) Spontaneous Ventilation Modes: Psv, Cpap, Bilevel /Similar, Bilevel St / Similare) Prvc/Pcv-Vg/Dynamic Bilevel/Or Its Equivalent Modef) Closed Looplung Protective Mode- Asv/Nava/Wobov/Alpv/Smart Care (At Least 1 Of The Mentioned Mode Is Mandatory)G) Should Have Pav (Proportional Assist Ventilation) / Pps (Proportional Pressure Support)/ Paps (Proportional Adaptive Pressure Support)H) Cpr (Resuscitation Mode),I)Niv In All Pressure Modes7. Hfot /Nasal Cpap Breathing Therapy Should Be Capable Of Adjusting The Range Up To 60Lpm8 A) Apnea Backup Ventilation In All Modes8 B) It Should Have Weaning Analyzer Tools : Sat & Sbt9. Should Have In-Built Nebulizer With Capability To Deliver Fine Particle Size Of To Be Used In Line10. Should Have Facility To Measure And Display The Following Parameters:A) Airway Pressure (Peak & Mean)B) Tidal Volume (Inspired & Expired)C) Minute Volume (Expired)D) Spontaneous Minute Volumee) Total Frequencyf) Fio2 Dynamicg) Intrinsic Peep, V Trap & Time Constant (Rcexp)H) Resistance & Compliance11. Automatic Compliance And Leakage Compensation For Circuit And Et Tube 12. Should Have Facility Of Logbook, For Events And Alarms With Date & Time 13. Should Have Following Setting & Monitored Parametersa) Tidal Volume; Pre-Set Range For Both Pediatric & Adult Modes To Be Providedb) Inspiratory Pressure (Up To 100Cm Of H2o);C) Respiratory Rate 1 To120 Bpm;D) Apnea Back Up Rate;E) Peep: 0-50 Cmh2of) Inspiratory Flow: 0-120 Lpmg) Max Peak Flow : 280 Lpm Or Betterh) O2 Concentration: 21-100%I) Pressure Support: 1-(100-Peep) Cmh20j) Fio2 Setting Range Between 21% And 100%;K) Pressure Flow & Volume Curves;L) Loop For V-Flow, Flow-P, Flow-Paw And At Least 5 Storage Spaces For Reference Loopsm) I: E Ratio: 150:1 To 1: 299N) Ramp Time: Up To 3 Seco) Inspiratory Time: 0.2 To 15Sp) Pause Time; Exp/Insp Holdq) Pressure Trigger: Up To -10Cmh2o And Flow Trigger Up To 20 Lpm;R) I Flow/T Plateaus) Resistance & Compliance (Cdyn & Cstat)T) Leakageu) P Plateau 14. Should Have Weaning Parameters;Rsbi,Vt Spont, R Spont ,Vt/Ibw15. Should Have Weaning Parameters;Rsbi,Vt Spont, R Spont ,Vt/Ibw16. Facility To Calculate Lower And Upper Inflection Point (P/V Flex Points)Should Have Recruitment Manoeuvre17. Should Have Automatic Suction Routine & O2 Flush18. Should Have A Dedicated Bronchoscopy Function To Allow & Compensate Ventilation While Performing Bronchoscopy19. Should Have Trend Of 7 Days And Above With Facility To Transfer Through Usb Interface20. Alarms Should Be User Friendly, Audio And Visual With Text Message, System Alarm Should Be For:A) Pressure Changes (High/Low)B) Tidal Volume Changesc) Minute Volume Changesd) High Peepe) High/Low O2 Concentrationf) Power Failure And Low Batteryg) Patient Disconnectionh) Apnea 21 A) The Ventilator Should Have Facility For Co2 Monitoring. Should Have Inbuild Etco2 Interface & Software To Accommodate External Optional Volumetric Etco2 In Future21 B) Should Be Upgradable To :Metabolic Monitoring (Indirect Calorimetry).Price To Be Quoted As Optional.22. The Ventilator Should Not Weigh More Than 12 Kgs 23. Ventilator Should Have In Built Non- Consumable Paramagnetic Oxygen Sensor That Shouldnot Require Change For At Least 5 Years.24. Flow Sensor Should Be Differential Pressure Technology, Or Ultrasonic.Flow Sensor Must Be At Expiratory End. Should Be Maintenance Free, Reusable And Autoclavable.The Flow Sensor, Inspiratory Port, Expiratory Port Should Be Easily Removable Without Using Any Tools & Should Be Autoclavable.25. Should Have Usb /Serial Interface For Communications With Networked Devices26. The Ventilator Should Have On Screen Help Menu For Alarm, Ventilation Mode & Ventilator Settings. The On Screen Help Menu Should Guide User On Solving The Alarms; Providing Information On Ventilation Modes & Settings. 27. Should Support Dual Limb Circuits Of Any Make And Not Ventilator Model Specific Circuits28. The System Should Have Inbuilt Rechargeable Battery With Backup With Minimum 2 Hours29. Power And Gas Requirements: A) Power Input To Be 220-240Vac, 50Hz (100-240 Vac) B) Gas Input (Air And Oxygen) - 29-100 Psi (29-87 Psi)30. The Ventilator Should Be European Ce Certified Or Us Fda Approved, And The Manufacturing Company Should Be Iso Certified.Accessories/Consumables To Be Supplied With Main Unit I. Icu Ventilator With Trolley – 1Nosii. Reusable Adultcircuit - 1 Nos Iii. Hinged Support Arm – 1 Nosiv. Hme Filters—5Nosv. Bacterial Filters-5Nos Vi. Hepa Filetr-1Nos Vii. Test Lung -1Nos Viii. High Pressure Oxygen Inlet Hose – 1Nos , Projector With Screen Brand - Epson / Benq / Lg Cinebeam Technical Specification Ce Marked, Power Supply: 220-240 V Ac, 50/60 Hz, Transparent Lcd Panel Display System, Minimum 5200 Hours Lamp Life, Min. 5800 Lumens Brightness, Contrast Ration 10000: 1, Aspect Ratio 16: 10, Resolution Xga (1024 X 786) With Hdmi And Vga In, Lan & Usb Support, Wireless Support, Light Weight, Remote Control Etc. , Phaco Emulsifier Machine Brand-Alcon Legion / Zeiss Technical Specification 1. Operating Frequency Should Be Approx. 40 Khz 2. Handpiece: Ultralight Ultrasound 4 Crystal Piezoelectric Hand Piece. 3. Us Modes: Continuous, Pulse, Single Burst, Multi Burst, Continuous Burst, Automated Programmable Modulation (Apm) 4. Automated Ultrasound Power On Demand: Ultrasound Management Technology That Automatically (De)Activates Ultrasound Us Delivered Only When Needed Ept Up To 50% Less & Better Followability. 5. Type Of Infusion: Iop Controlled, Synchronized Fluid Exchange System That Directly Measures And Simultaneously Controls Both Infusion And Aspiration Volumes In Real-Time. It Actively Compensates For Incision Leakage. Quattro Controlled Forced Infusion. 6. Display: 24 Inches Touch Screen. 7. Iop Range: 30-120 Mmhg 8. Vacuum Range 0 To 700 Mmhg 9. Aspiration Flow Rate 0 To 120 Cc/Min 10. Aspiration Control Modes: Vacuum Controlled Mode, Flow Control Mode 11. Chamber Stability: Irrespective Of Type Of Cataract, Surgical Conditions, Leakage (0 -12 Ml/Min) It Keep Chamber Stable & Maintain Targeted Iop Throughout Procedure. 12. Iop Recovery Time After Occlusion Break 200-250Ms For Vacuum In Range Of 200 -600Mmhg. 13. U/S Tips: Coaxial Phaco With Incision Size 2.2 Mm 14. Vitrectomy: Pneumatic Cutting Device15. Type Of Vitrectomy Cutter: 23G Anterior Vitrectomy Cutter16. Anterior Vitrectomy Range:Cut Rate 30 To 5000 Cuts Per Minute. 17. Actuation Medium For Vitrectomy: Compressed Air From Internal Source 18. Diathermy: Bipolar With Fixed And Linear Control Via Foot Pedal. 19. Type Of Diathermy Handpiece: Diathermy Forceps And Diathermy Pencil Eraser. 20. Instrument Tray Arm Length: Should Be 800Mm Or More. 21. Dual Linear Footswitch 22. Should Be Usfda And Ce Approved 23. Online Ups Should Be Providedaccessories: Phaco Hand Piece(Coaxial) -2 Coaxial Handpiece Tip I – 2 I/A Bi Manual Hand Piece – 2Phaco Tip (2.2 Mm)- 10 Phaco Sleeve (Silicone)(2.2Mm) – 10 Test Charnber- 10 Tubing And Cassettes (Disposable) – 100 Diathermy Cable With Forceps – 2 Phaco Wrench-2 Vit Cutter- 23 G; Single Use – 6Sterilization Container/ Tray , Autorefractometer & Keratometer (Ark) Brand-Zeiss- Visuref 150 Technical Specification (A)Device Data.(A) Refraction(1) Sphere -25.00D To +22.00D (In Steps Of 0.12D/0.25D)(Ii) Axix 0 To 180*) (B) Keratometer(A) Corneal Curvature 5.00 To 10.20Mm (In Steps Of 0.01Mm)(B)Corneal Redraction-33.000 ?? 67.50D (In Steps Of 0.12D/0.25D)(C) Corneal Astigment-0.00D To-15.00D50d (In Steps Of 0.12D/0.25D)(D)Axis 0 To 180* (In Seps Of 1*) (E) Corneal Diameter (2.00 To 1200Mm (In Steps Of 0.10Mm) , Humphrey Fied Analyzer ( Hfa3) Brand-Zeiss Technical Specification • High Quality Goldman Standard Automated Full Field Perimetry Of International Standard With Bowl Size Radius = 30Cm. • Computer & Monitor Should Be Integrated In The Perimeter (No External Computer). • Stimulus Size I, Ii, Iii, Iv & V.• Background Illumination 31.5Asb.• Maximum Temporal Range 80Deg.Suitable For Central 30, Neurological Tests As Well As Full Field Testing. • Central Field Test Patterns 30-2, 24-2,10-2, Macula.• Peripheral Field Test Pattern 60-4, Nasal Step, Custom Test. • Threshold Test Strategies Full Threshold, Sita Standard, Sita Fast , Full Threshold, Fast Pack, Sita - Swap.• Screening Field Test P-60, Ff-80, Ff-120, Ff-240,Nasal Step For Periphery .• Screening Test Strategies Two Zone, Three Zone And Quantify Defects.• Glaucoma Hemi Field Test, Heijl –Krakau Blind Spot Monitor• Video Eye Monitoring, Gaze Tracking Monitoring System, .. Vertex Monitoring And Head Tracking. • Touch Screen On Crt Monitor, Keyboard & Provision Of External Monitor & Keyboard.•Internal Hard Disk Drive.• Stimulation Duration 200Ms, Wavelength Broad Band Visible Light• Stimulus/Background Colour White On White.• Swap (Blue On Yellow) Perimetery. • Auto Pupil Measurement. • Kinetic Testing & Custom Kinatic Testing. • Motorised Chinrest, Motorised Table, Laser Jet Printer • Glaucoma Progression Analysis ( Gpa ) Software For Monitoring Disease Progression. With Visit Wise Graph &Visual Field Index (Vfi).• Releye Monitor.• Forum Software For Archiving & Offline Analysis Of Patient Data & Gpa Analysis Etc.• Hfa Dicom Gateway. , Laser Dcr Brand-Medfin Technical Specification Applicationsdacryocystorhinostomy Amplifying Medium Diode Ergonomics Tabletop Wavelength-980Nm Average Power -8W Weight -1.2Kg (2.65Lb) , Automatic Tourniquet System With Hose Cuffs Brand - Zimmer Biomet (Model Ats-5000) Number Of Ports Dual Port Number Of Potential Cuffs Dual Cuff Dual Cuff Mounting Options Table Or Pole Mount Table Or Pole Mount Battery Type And Life Lithium Ion 6 Hrs Lithium Ion 6 Hrs User Interface Touchscreen Touchscreen International Alarm Standard 60601-1-8 Compliant Compliant Display 10.1” Color 7.0 Color Minimum/Maximum Pressure 20/600 Mmhg 50/600 Mmhg Pressure Accuracy ±3 Mmhg (20–600 Mmhg) ±4 Mmhg (50-600 Mmhg) Limb Occlusion Pressure (Lop) Allows For Patient Specific Pressure, Which Allows For The Minimum Pressureto Be Used.Yes Noline Occlusion Detection (Acoustic Reflectometry)A Kinked Pneumatic Tube Can Prevent An Inflated Cuff From Deflating, Resulting In Unintentional Tourniquet Pressure. This Alarm Alerts Or Staff That There Is An Occlusion In The Line To The Cuff.Yes , Battery Opreated Heavy Duty Drill & Saw Brand -Manman/Biotech Specifications--- Drill And Reamer Hand Piece Attachments, Oscillating/S Reciprocating Saw Hand Piece Charger And Sterilization Handpiece For Drilling & Reamingtrigger Type Single Modes Available - Reverse & Forward Modedrill Speed 1000 Rpm Approxdrill Torque 4 Nm (35+ In Lbs)Ream Torque 16.5 Nm (145+ In. Lbs)Weight Of Hp With Batteries 1250 Gms Drilling And Reaming Attachments Hudson/Zimmer/Trinkle Reamer Attachment - Yesao Reamer Attachment - Yesao Type Drill Attachment With Quick Coupling - Yesjacobs Chuck With Minimum 6 Mm - Yeskeyless Chuck -Yes Wire Driver Attachment - Yespin Driver Attachment - Yes Dhs Reamer Attachment With Quick Coupling - Yesoscillating/Sagital Saw Hand Pieceergonomic Pistol Grip Design For Maximum Comfort And Control Yes Weight Of Hp With Batteries.- 1350 Gmssaw Speed - 15000+ Cpmcutting Arc - Between 4 To 5 Degreenoise Level - 60-85 Dblspecial Blades Each For Tkr And Thr (Nos) - 10 Battery Specifications Type Of Battery Lithium Ion (Li-Ion) Number Of Batteries 2 , Electric Cautery Machine Brand - Shalya/Enertech/Eclipse/Valley Lab 1) Unit Should Have Microprocessor-Controlled Tissue Feedback Technology 2) Unit Should Have No Of Bipolar Modes Available 3) Unit Should Have Pure Sinusoidal Output Waveform In Hf Power Output In Cut And Bipolar Modes. 4) Type Of Display Should Be Lcd Touch Screen 5) It Should Adjust Power Level Automatically Depending On Tissue Type. 6) It Should Have Two Monopolar Output Channels. 7) Bipolar Current Meter Bipolar Current Meter 8) Unit Should Deliver Two Coagulation Output At A Time With Independent Control Over Each Output For On & Off. 9) Both Channels Should Work By Foot And Hand Control. 10) It Should Complete Self Testing During Power On. 11) Power Efficiency 98 Or More Than 98 12) Availability Of Advance Cutting Modes For Regular Open Surgery 13) It Should Accept Disposable And As Well As Reusable Patient Plate. 14) Unit Should Have Tissue Feedback, Pulsed Interval-Controlled Pulse Cut Function. 15) It Should Accept Dual Area And Single Area Patient Return Electrode. Should Give Green Indication If Dual Area Patient Plate Applied To Patient & Red Indication With Alarm Tone If The Patient Plate Is Not Applied. 16) Bipolar Should Work Without Patient Plate Or Patient Plate Error Condition. 17)Bipolar Should Have Auto Facility To Start & Stop Working Without Footswitch. 18) Unit Should Have Adjustable Delay Activation In Auto-Bipolar. 19)It Should Have Randomized Spray Coagulation For Larger Area Coverage.20)It Should Be Upgradeable For Argon Delivery Module From The Same Oem.21) Unit Should Be Useful For Underwater Procedures. 22) It Should Have Alarm Facility After Completion Of Bipolar Coagulation. 23) Unit Should Have Time Out Function For Automatic Stop The Hf Output If Prolong Unintended Activation. (Optional)24) Unit Should Have Touch Key Pad For Power And Mode Selection.25) System Should Give Error For Faulty Handswitch Of Footswitch In Monopolar & Bipolar.26) Unit Should Give Error For Faulty Keypad. 27) It Should Have No Of Segments Of Display 3. 28) Unit Should Operate From 180 V To 265 V Without Using External Stabilizer. 29) It Should Have Independent Foot Switch For Monopolar Two Paddle. 30) It Should Have Independent Foot Switch For Bipolar Single Paddle. 31) Unit Should Have Facility To Connect Either Monopolar & Bipolar Footswitch.32) Unit Should Have Remote Power Setting Facility From Sterile Field With Conventional Hand Switching Pencil. 33) It Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification. 34)Manufacturer Iso 9001: 2008 & En Iso 13485:2012 Certified Company.35) Warranty Must Be 3 Years Or Higher 36) It Should Be Supplied With Following Reusable And Autoclavable Accessories: -1. Patient Return Electrode …………………….1 No.2. Hand Switching Pencil………………………. 1 No.3. Foot Switching Pencil…………………………1 No.4. Bipolar Forceps …………………………………1 No.5. Cable For Bipolar Forceps……………………1 No.6. Monopolar Footswitch ………………………1 No.7. Bipolar Footswitch ……………………………1 No. 8. Universal Adaptor …………………………….1 No.Set Of Electrode (Angled, Ball And Needle).1No10. Trolley With Lockable Castor Wheel Should Be Supplied1. Unit Should Be Eu Ce (4 Digit Notified Body Certified)2. All Sockets Should Be Of Blinking Light Type When In Use To Identify The Used Mode 3. Availability Of Test Report From Central Govt/ Nabl/Ilac Accredited Lab Covering All Parameters. And Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification. , Arthroscopy Set (Brand- Smith +Nephew / Karl Storz) Arthroscopy Set 30° (Arthroscopic, Sheath And Obturator) Wide Angle, Direct View 4K High Definition Arthroscope. Light Guide Insertion On Definitione Direction View With A J-Lock Fixation For Cannula.Working Length Of Not More Than 160Mm Optimal Centre-To-Edge Resolution For Enhanced Picture Quality Angle Of View: 30 Degree Diameter: 4Mm Arthroscopies Should Be Supplied With Compatible Cannulas High Flow, Double Valve, Fully Rotatable With Fenestrated Tip & Conical And Blunt Tip Obturator, Sheath- 5.95 To 6.0Mm, High Flow Diagnostic Cannula, Double Valve, Fully Rotatable Cannula With Fenestrated Tip. Trocar-4.5Mm Conical Obturator To Fit With Cannula. Arthroscopy Set 70° (Arthroscopic, Sheath And Obturator) Wide Angle, Direct View 4K High Definition Arthroscopic Light Guide Insertion On Opposite Side Of The Direction Of View With A J-Lock Fixation For Cannula. Fully Rotatable With Fenestrated Tip & Conical And Blunt Tip Obturator. Sheath- 5.95 To 6.0Mm, High Flow Diagnostic Cannula, Double Valve, Fully Rotatable Cannula With Fenestrated Tip. Trocar-4.5Mm Conical Obturator To Fit With Cannula. Arthroscopic Power Shaver System: Input Voltage Of 100 To 240V, 50/60 Hz Power Consumption Not More Than 350Va. Two Separate Receptacles For Motor Drive And Powered Instrumentation. Shaver Should Have 2 Modes Of Oscillation For Aggressive Cutting Shaver Should Have Button For Flush Lavage Of Joints On Footswitch. Autoclavable Ultra-Light Hand Piece With Suction Facility, With 3 Hand Control Buttons And Replaceable Cable Long 10Ft (3 M). Maximum Torque Should Not Be Less Than 32Oz.In And Weight Should Not Be More Than 212 Gms Pedal Style Footswitch With 3 Operating Modes I.E. Forward, Reverse And Oscillation. On-Line Lcd Display For Speed And Direction Referral. Should Communicate With The Fluid Management System Once Connected With The Cable. Camera Control Unit: System Must Have Inbuilt 4K Uhd Camera Console, Led Light Source & Wifi Enabled Image Management System With Recording Via Usb Port Along With Recording In App Through In Built Wifi. Camera Resolution Must Be 3840*2160 (Native) 4K Camera Head: Camera Head Should Have 4K, 3 Chip Mos Video Sensor Technologymust Have Transport Shock And Vibration Compliance With Ista 3Avideo Field Rate 60 Hz Must Have C-Mount Autoclavable Coupler With 19.5 Mm Coupler Length Opt For 4Mm Scopes Must Have Digital Zoom Video Data Transmission High-Speed, Low-Voltage Differential Serial (Lvds), Digital Transmission Via 12-Foot Camera Cablevideo Output Format Full Uhd 2160P, 100% Compatible With Smpte St-425-5 When Used With The Ccu Altitude: 3000 Meters Maximum 4K Monitor: Monitor Should Have Resolution 4096 * 2160 Pixels Monitor Should Support Picture Size (Diagonal) 789.06 Mm (31 1/8 Inches) 1387.8 Mm (54 3/4 Inches) Monitor Should Support Effective Picture Size 698 * 368.1 Mm (27 1/2 * 14 1/2 Inches)Monitor Should Support Pixel Pitch 0.1704 X 0.1704 Mm Monitor Should Have Aspect Ratio Of 17:09Monitor Should Have Pixel Efficiency Of 0.9999 Size Is -125Mb 1300 Seconds Video / Gigabyte Storage 10000 Images/Gigabyte Storage Airprintt Is Required. , Fess Instruments Set Nus Surgery Fess & Dcr Surgery Instruments Brand -Kalelkar / Besco Blakesley Forceps 0 Blakesley Forceps 45Blakesley Forceps 90° Thrucut Forceps 0Thrucut Forceps 45° Thrucut Forceps 90 Maxillary Sinus Forceps 30, 90, 120Hewiser Forceps Tubular Rotatable Kerrison Punch Straight Kerrison Punch Curved Backbiting Forcep Tubular Rotatable Stammberger Ostrum Punch (Mushroom Forceps)Giraffe Forceps Upturned 55, 70, 90, 110 With Vertical Or Horizontal Opening Fronntal Sinus Bougie Set Of 4Sickle Knife Sharp/Blunt Ball Probe Double Ended Right Angledball Probe With J Hook Double Endedantrum Curette Oval Or Round Cup Suction Canulla 45 Or 90° , Micro Ear Surgery Instrument Set (Ear Surgery Instruments) (Stapedectomy Instruments) Brand -Kalelkar / Besco Technical Specification Sickle Knife , Circular Knife Flag Knife , Sickle And Flag Knife Double Ended , Sickle And Circular Knife Double Ended Circular And Flag Knife Double Ended , House Curette Double Ended, Elevator Pick Straight/Curved/Right Angled , Fisch Perforator 0.3 Mm To 0.8 Mm. Hand Burr , Piston Depth Guage , Stapedectomy Instruments , Piston Cutting Jig Piston Autoclaving Box , Teflon Pistonspistion Crimper Micro Ear Scissor Belluchi Operative Ear Speculam Set Of 4 Black Slotted Or Plain Endural Retractor 2X2endural Retractor Left/Right Plester Micro Suction Canulla 116 To 24Gmicro Suction Canulla Adaptor Silicone Suction Tubecartilage Slicer , Tonsillectomy Instruments Set Brand -Kalelkar / Besco Technical Specification Davis Boyles Mouthgag With 5 Blades Davis Boyles Mouthgag With 5 Slotteddraffin Bipod Stand With Plate Tonsil Holding Forceps Tonsil Dissector Cum Pillar Retractortonsil Dissection Forceps Tonsil Artery Forceps Straighttonsil Artery Forceps Curvedtonsil Artery Forecps Negustonsil Scissor Tonsil Snare Tonsil Snare Wire +Quincy Foreps +Adenoid Curette With Cage + Adenoid Currette Without Cage + Younker Suction Canulla +B.P.Handle No 7 + Negus Knot Tier +Thrroat Instruments Tracheatomy Surgery Instruments + Tracheatomy Tube Chevalier Jackson/Fuller + Mosquito Artery Forceps + B.P.Handle No 3 + B.P. Blade No 11 + Fine Scissor 4 +Tracheal Dilating Forceps + Kilner Catpaw Retractor +Skin Hook + Single Hook Retractor +Double Hook Retractor , Nasal Surgery Instruments Set (Septoplasty Instruments) Brand -Kalelkar / Besco Technical Specificationkillians Nasal Speculam 2 To 3.5 + St. Clair Thomson Nasal Specularm Set Of 4 B.P. Handle No 3+Freersdouble Ended Mucopericondrial Elevator + Symes Double Ended Mucopericondrial Elevator + Howarth Double Ended Mucopericondrial Elevator Symes Double +Suction Elevator + Lucs Forceps Round Or Heart Shape + Jensen Middleton Septum Cutting Forceps + Jensen Middleton Septum Punch Forceps + Turbinectomy Scissor + Ballenger Swivel Knife Bayonet Shape + Tilleys Nasal Gouge Bayonet Shape With V Cut Or. Plain + Hammer (Mallet) + Submucosal Diathermy+ Needle/Ball Probe + Nasal Packing Forceps + Spring Scissor + Catspaw Retractor + Tongue Depressor + Rhinoplasty Surgery Instruments + Raps + Cricoid Hook + Jenkins Chisel + Alar Retractor + Aufritch Nasal Retractor + Ash Septum Forceps + Walsham Septum Forceps + Gillies Osteotome + Nasal Packing Forceps + Silver Nasal Chisel With Guard Left/Right + Skin Hook + Cottle Retractor + S.M.R Instruments + Killians Nasal Speculam 2 To 3.5 + St. Clair Thomson Nasal Speculam Set Of 4 + Freers Double Ended Mucopericondrial Elevator + Symes Double Ended Mucopericondrial Elevator + Howarth Double Ended Mucopericondrial Elevator + Suction Elevator + Turbinectomy Scissor + Ballenger Swivel Knife Bayonet Shape + Tilleys Nasal Gouge Bayonet Shape With V Cut Or Plain + Hammer (Mallet) , Micro Laryngeal Surgery Instruments Set Brand -Kalelkar / Besco Laryngoscope Mls Black Finish Adult/Child/Paediatric With Fiber Optic Carrier Chest Supportlaryngoscope Distending Operating Type Laryngoscope For Filling With Endoscopemls Forceps Cup Type Straight/Left/Right/Upward/Downward Mls Forceps Serrated Type Straight/Left/Right/Upward/Downwardmls Scissor Straight/Left/Right/Upward/Downward Mls Vocal Cord Spreader Mls Mini Larygeal Forceps Triangular End Mld Needle Holdermls Ssickle Knife Mls Circular Knifemls Flag Knifemls Probe 45°, 90°Mls Curettemls Handle For Use With Straight Instumentssuction Tube With Thumb Control Insulated Probe For Coagulationbronchoscope/Esophagoscope & Instrumentsbronchoscope Negue Type Any Size With Fiber Optic Carrier Esophagoscope Any Size With Fiber Carrierhypopharyngoscope (Esophageal Speculam) With Fiber Optic Carrier Forceps Alligator Grasping Single Actionforceps Peanut Soft Tissue Single Actionforceps Cub Biopsy Type Single Action Forceps Patterson Type Single Actionforceps Universal Biopsy & Grasping Single Actionforceps Alligator Grasping Double Actionforceps Peanut Soft Tissue Double Actionforceps Cup Biopsy Type Double Actionforceps Patterson Type Double Actionforceps Universal Biopsy &Ngrasping Double Action Suction Tube Rigid With Thumb Conntrol , Mastoid Surgery Instruments Set Brand -Kalelkar / Besco B.P. Handle No 4 Kilner Catspaw Retractormollison Mastoid Retractor 3X3 Mollison Mastoid Retractor 4X4mahadevaiah Modified Mastoid Retractor Left/Right Jensen Retractorjolls Retractor Periosteal Elevatoroperative Ear Speculam Set Of 4 Black Slotted Or Plain Micro Suction Canulla 11G To 24Gmicro Suction Canulla Adaptor Mastoid Suctioncanulla Set Of 4 With Thumb Grip Sickle Knifecircular Knifeflag Knife House Curette Double Ended Elevator Adsons Toothed Forceps Adsons Non Toothed Forceps Needle Holder 6 Fine Scissor 4Micro Ear Crocodile Serrated Forceps Micro Ear Crocodile Cup Forceps Micro Ear Crocodile Scissors Malleus Nipper Ball Probe 45 Degree/90 Deegre Vien Graft Pressossicle Holding Forceps , Fiberoptic Flexible Video Laryngoscopy System Brand -(Penlon / Karl Storz) Specification 1) It Should Be Very Portable And Light Weight Device With Minimum Display Size Should Be 4 Inch With High Resolution Anti Reflective Display. 2) Should Have 180 Degree Horizontal Screen Rotation With Vertical Movement For Betterclinical Assistance. 3) It Should Be A Lithium Ion Rechargeable Battery-Operated Device With Low Battery Indicator. 4) Minimum Operation Item Should Be 130 Mins. 5) It Should Have Led Light Source At The Tip Of The Blade With Minimum 2 Megapixel Cmos Camera For Better View. 6) It Should Have Channelled And Without Channelled Blade Option. 7) Should Have 4Gb Inbuilt Memory For Continuous Recording & Image Capturing. 8) Blades Sizes Should Be Size 1,2, 3, 4,5 . 9) Blade Should Be Affordable, Sterile Which Connect Laryngoscope Handle With Lock. 10) Battery Life Cycle Should Be Minimum 300 Times. 11) It Should Have Iso & Conformity To Ce. , Fiber-Optic Video Bronchoscope(Brand - Karl Storz /Olympus ) Specification Fiber-Optic Video Bronchoscope Required With Video Illumination To Visualize And Document The Operational Area On Screen. It Should Consist Of Following Features: Monitorscreen 8 To 12 Inch In Size For Display With Touch Screen To Control Features With Hdmi Output For Connecting To A Big Screen Which Can Display Picture Simultaneously On Both Screens.Monitor Should Have Two Ports To Connect Two Video Endoscopes At One Time And Pictures Can Be Swapped Using Touch Screen. Monitor Should Be Chargeable, To Be Supplied With Charger And Should Have Facility To Be Used While Charging. Monitor Resolution Should Be Minimum 1920 X 1200 Pixels In 16:9 Format.Integrated Recording Of Video & Still Images Should Be Possible On Data Card Or Usb Drive With Jpeg And Mpeg Format Which Can Be Easily Transferred To The Computer/Laptop. Documented Videos & Still Images Should Be Easily Recalled On The Monitor. Monitor Should Have A Facility To Connect Flexible Scope Directly Without Any Special Coupler Or Accessory. Monitor Should Have Picture-In-Picture & Side-By-Side Mode To View Images From Flexible Video Scopes. Monitor Should Be Splash Proof According To Ip 54 And Should Be Shock Resistant.Monitor Should Have Lithium-Ion Rechargeable Batteries And Run For At Least 100 Mins. When Fully Charged. Soft Bag From Same Manufacturer Should Be Supplied To Place The Monitor And System Can Also Be Operated Without Taking Monitor Out From The Bag. Same Monitor Should Be Compatible With All The Below Mentioned Scopes Of Same Manufacturing Principal Company .Reusable Fiber Optic Video Bronchoscope.Single Use Flexible Intubation Video Endoscope A Fiber Optic Bronchoscope Is A Medical Device Used To Visualize The Airways During Bronchoscopy, A Procedure Where A Thin, Lighted Tube Is Inserted Into The Lungs To Examine Them. The Specifications Of A Fiber Optic Bronchoscope Typically Include Its Outer Diameter, Working Length, Field Of View, Angulation Capabilities, And The Diameter Of Its Working Channel. Key Specifications:Diameter: Bronchoscopes Come In Various Sizes, With Outer Diameters Ranging From 2.5 To 10 Mm. Smaller Diameters (E.G., 4.9 Mm) Are Suitable For Smaller Patients, While Larger Diameters May Offer Better Image Quality And Suction Capabilities. King Length: The Working Length, Which Is The Distance From The Distal End Of The Bronchoscope To The Insertion Point, Typically Ranges From 30 Cm To 60 Cm. View: This Refers To The Angle Of Vision That The Bronchoscope Offers. A Wider Field Of View (E.G., 110-120 Degrees) Allows For A Broader View Of The Airways. Angulation: The Ability To Bend The Tip Of The Bronchoscope Allows For Maneuvering Into Various Airways. Up And Down Angulation Capabilities Are Typically Around 180 Degrees And 130 Degrees Respectively King Channel Diameter: The Working Channel Is The Passage Through Which Instruments Like Forceps For Biopsies Or Suction Devices Can Be Passed. It Is Typically 1.2-2.3 Mm In Diameter Other Notable Specifications: 26/25 All Above Equipment Should Be From Same Manufacturers And Usfda & Ce Approved , Anaesthesia Workstation Complete With Anaesthesia Gas Delivery System, Vaporiser, Circle Absorber System With Built In Anaesthesia Ventilator & Withmultipara Monitor Brand - -Drager/Penlon/Bpl General • Should Have Provision For Delivery Of Oxygen, Nitrous Oxide And Medical Air • The Machine Should Be Capable Of Delivering Low Flow Anaesthesia. • The Anaesthesia Machine With Circle Absorber, Ventilator And Vaporiser Should Be From Same Manufactureranaesthesia Machine Should Be Ce Notified Body Approved. • Anaesthesia Machine Should Be Cdsco Approved. Vaporizer Should Be Us Fda Approved.Should Have Independent Attachments For Connecting Central Gas Supply And Pin Indexed Cylindershould Have Non-Interchangeable Pipeline Hose Inlet Connection To Pipelines For Medical Oxygen, Nitrous Oxide, And Medical Air Should Have Large Size Pressure Gauges, For Easy Visibility, Colour Coded, Two Each For Oxygen And Nitrous Oxide; One For Airanaesthesia Machine Frame Shall Be Manufactured In Strong But Lightweight Material.The Machine Shall Have A Maximum Of Four Castors/Wheels For Manoeuvrability With Front Two Castors Having Brakesshould Have Minimum Two Non-Lockable And Spacious Drawers For Storing Accessoriesthe Frame Shall Have Gcx Compatible Channels Incorporated For Mounting Other Accessories. • The Option For An Integrated Independent Oxygen Flow Meter For Oxygen Delivery Is Mandatory. Frame Shall Accommodate Up To Two Backup Cylinders One Each For Oxygen And Nitrous Oxideon Activation Of The System On/Off Switch Gas Flow And Vaporization Shall Immediately Be Availableshould Have Selector Switch For Selecting Open And Close Circuit Operation • The Common Gas Outlet Shall Be Mounted At The Front Of The Machine (Not Rear Or Side) To Be Easily Accessible In The Event Of An Emergency And For Use Of Alternate Breathing Circuits • The Option For Illumination Of The Writing Table/Work Surface Is Mandatory • The Frame Should Have Integrated Power Outlets To Supply A Minimum Of Three External Devices • Should Have Top Shelf, Manoeuvring Handle And Footrest • Machine Should Have Table Topwork Space To Keep Drugs. • The Unit Should Have A Battery Back-Up Facility For The Ventilator In The Event Of Power Loss. Minimum 90 Minutes Battery Backup Required. • Input Power :100 – 240 Vac Gas Flow • Antistatic And Cascaded Dual Flow Tubes Should Be Available For All Gases (O2, N2o& Air) To Allow Suitable Resolution And Accurate Control At Low Total Fresh Gas Flows. • The Flow Range Shall Be 150Ml-10 Lpm • Should Have N2o Cut Off Facility If O2 Supply Fails. • Should Have Oxygen Failure Alarm Both Visual And Audible. • Should Have Oxygen Flush Facility Bypassing Vaporiser. O2 Flush Switch Should Be Conveniently Placed For Easy Accessibility. O2 Flush Switch Should Be Non-Lockable. • The Unit Shall Have A Mechanical Anti-Hypoxic Device (Ahd) System To Control The Ratio Of Oxygen And Nitrous Oxide. A Completely Mechanical Ahd System, That Requires No Electricity, Is Mandatory • The Mechanical Ahd System Must Limit Minimum Oxygen Levels To Approximately 25% • Should Have Minimum Mandatory Oxygen Flow Of 100 Ml When Switched On • It Shall Be Possible To Deliver Air With Only Basal Flow Oxygen Independent Of The Abovementioned Hypoxic Control. • Gas Flow Shall Be Controlled Mechanically Only • Visual Display Of Individual Gas Flows Is Mandatory, This Shall Be By Physical Means Such As Glass Flowmeters Independent Ofelectrical Power • Flow Meters Should Have The Option Of Backlight Illumination • In The Event Of Complete Power Loss And Battery Failure It Shall Still Be Possible To Set The Fresh Gas Flow Accurately For Each Gas, Manually Ventilate (With Bag) And Continue To Keep The Patient Anaesthetized. • Anaesthesia Machine, Vaporizer And Ventilator Should Be From Same Oem. • Provide Isoflurane And Sevoflurane Vaporizer With Themachine. Vaporizers • The Unit Should Accommodate At Least Two Vaporizers For Anaesthetic Agent Delivery. • The Manifold Should Only Accept Vaporizers With Approved Back Bar Connections And Prevent Usage Of More Than One Vaporizer Simultaneously. Preferably Selectatec Compatible Back Bar. • Vaporizers Supplied With The Unit Shall Be Routine Maintenance Free For The Life Of The Product • Vaporizers Supplied With The Unit Shall Be Manufactured From Lightweight Materials To Aid In Fitting & Removal • Should Have An Operating Flow Range Of0.2 – 15 L/Min And Nominal Capacity 250 Ml Ventilator • Ventilator Shall Cater For A Diverse Range Of Patient Groups From Neonates To Adult Patients With Restrictive Airways • Ventilator Should Be Pneumatically Driven And Controlled Electronically • Ventilator Shall Have A Large 8.4” Colourtft Display, For Exclusive Use Of Ventilator Control And Monitoring. • Control Ofthe Ventilator User Interface Shall Be By Touch Screen And Rotary Dialventilator Shall Have The Following Ventilation Abilities, Volume Control (Vcv), Pressure Control Ventilation (Pcv), Simv-V And Simv-P ,Spont/Pressure Support Ventilation (Psv),Manuaassisted Modes Of Breathing Shall Be Flow Triggered. Ventilator Shall Compensate For Fresh Gas Flow And Compliance Of The Entire Circuit. Should Have User Adjustable Alarms For Major Parameters Such As Tidal Volume, Minute Volume,Fio2,Airway Pressure, Frequency Apnea Alarms Must Be User Adjustableto Allow For All Operating Conditions And Phases During Anaesthesia Ventilator Should Have The Ability To Display Patient Spirometry Loop Ventilator Should Also Display Waveforms For Flow, Volume And Airway Pressure Stem Absorber & Not Remoted Via Tubes Or Channelsvolume Measurement Sensors Should Not Be Disposable Typeventilator Parameterstidal Volume- 10Ml-1600 Mlfrequency- 4-100 Bpm I:E Ratio- 4:1 To 1:10 Inspiratory Pause - 0-60% Of Ti Peep - Off, 3-30 Cmh2o Pressure Limit - 5-70 Cmh2o Minute Volume-0.5 To 60 Lpm Breathing System • The Breathing System Designed So That It Can Be Removed & Replaced As A Complete Unit Without The Use Of Tools • All Parts Of The Breathing System That Are In Contact With Patient Gas Shall Be Latex Free And Autoclavable Except For Non Autoclavableremovable Part Like O2 Sensor And Pressure Manometer. • Bag/Vent Switch Shall Be Integrated On The Absorber And Should Activate Ventilator In Vent Mode And Vice Versa (One Step Operation). • Breathing System Should Have Heater System To Avoid Water Condensation. • Should Have Quick Release Canister For Sodalime , Capacity Minimum 1.5 Litre • The Breathing System Absorber Canisters Shall Have A Bypass System To Allow For Canister Change Mid-Case Without Loss Of Ventilation Pressure. The Requirement For An Automatic Bypass Without Extra Input From The User Is Mandatory • The Ventilator Bellows Shall Be Clearly Visible And Be Of Upright Design.The Bellows Should Ascend On Expiration To Provide A Quick Visual Indicator For Assisted Breathing, Spontaneous Breathing And System Leaks. • Same Bellows Shall Be Used For Adult And Pediatric Application • Should Have Provision For Fio2 Monitoring Cell And Fio2 Value Should Be Monitored On The Main Screen. • A Bag Arm With Positional Adjustment Shalmulti Parameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,( Massimo),Nibp (Suntech) Temperature,Dual Ibp, Agm ( Massimo) Mainstream. 3. Should Have 12-Inch Color Lcd Display. 4. Should Have Dual Modes Of Operation: Rotary Knob. 5. Should Display 7 Waveforms Or More 6. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen. 7. Ecg: ? Should Be Able To Monitor Ecg Through 5-Lead Patient Cable ? Should Have Manual St Analysis Window ? Should Detect 20 Arrhythmias And Generate Alarms. ? The Priority Of Arrhythmia Alarms Can Be Configurable ? Should Measure Pvc & Pac ? Should Be Able To Monitor Heart Rate From 10-300 Bpm ? Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etc ? Should Have Pacemaker Detection Facility 8. Respiration: ? Measurement Range Of 0 To 150 Breaths Per Min ? Should Have Gain Selection: ×0.25, ×1, ×2, ×4 ? Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S ? Should Have Apnea Detection Facility ? Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 9. Spo2: ? Should Have Massimo Technology ? Should Have Measurement Range Of 0~100 % ? Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph ? Should Be Able To Select Sat Sec To Avoid False Alarm 10. Nibp: ? Must Be Of Suntech Medical Technology For Clinical-Grade Blood Pressure Measurement ? Should Have Auto, Manual, And Stat Modes Of Operation For Nibp. ? Should Have A Measuring Range Of 0-280 Mmhg 11. Should Have 2 Channels For Temperature Monitoring 12. Should Have Data Storage Capabilities: O 72 Hours Of Trend Data Storage. O 2000 Sets Of Nibp Measurement Data. O 200 Alarm Events O Physiological Alarms Can Be Reviewed With 16 Sec Of Associated Waveform Along With Other Parameter Values. Even Print Out These Waveforms With Optional Recorder O 7 Leads Of Ecg Waveform Disclosure At Least Of 1-Hour O Should Have Facility To Transfer The Trend Data To Usb 13. The Monitor Should Have Drug Dose Calculator And Oxy-Crg View Screens 14. Snapshot Facility With Usb Transfer. 16.Should Have Alarm Settings For All Parameters. 17.Should Have Color Coded Alarms And Alarms Priority Can Be Configurable. 18. Should Have Cns Connectivity Of Same Make. 19.Monitor Should Be Able To Directly Connect With Hospital Information System (His 20.Should Have Standby And Night Mode 21.Should Have Li-Ion Battery 22.Battery Should Have 3.5 Hrs Of Operation 23.Monitor Should Be Ce Certified 24.Manufacturer Should Be Iso Certified 13485:2016 , Bi-Phasic Defibrillator Brand - Bpl/Maestros Technical Specifications For Bi-Phasic Defibrillator • The Machine Should Have Facility For Ecg Monitoring, Bi-Phasic Defibrillation,With Facility To Print Ecg Through In-Built Thermal Printer,• Should Be Extremely Light-Weight (Less Than 10 Kgs) • Should Have Monitoring Facility Through Color Tft Display With Screen Size At Least 7” Or Better. • Should Have Both Synchronous And Asynchronous Mode. • The Defibrillator Should Be Biphasic Technology Based Having Energy Selection Of 2-300 Joules• It Must Be Capable Of Monitoring Ecg Through Ecg Cables, Multi-Function Electrodes And External Paddles. • The Machine Should Be Able To Defibrillate Adult, Paediatric Patients. • The Machine Should Have Ecg Wave Form Display On Bright Screen Along With Other Vital Numeric Information. • Should Be Able To Monitor Ecg• Should Have Facility For Auto Testing When Switched On And During Operations. • The Machine Should Be Compact, Portable With Built In Rechargeable Battery. • Should Have External Pacemaker With Fixed Or Demand Mode. • Should Be Able To Deliver A Maximum Of 300J In Aed Mode • Should Have A Minimum 2 Hours Battery Capacity For Monitoring And 1 Hour Battery Capacity For Giving Minimum Of 100 Shocks.• Energy Selectiononfront Panel Button And External Paddle Buttons • Charge Control On Front Panel Button And External Paddle Buttons • Charge Indicator Charging Tone, End Of Charge Tone, Led In Charge• Shock Control Buttons On The External Paddles • Should Have External Defibrillator Adult And Paediatric Paddles.• Charging Time - Less Than 8 Seconds At 300 J With A New And Fully Charged Battery • The Machine Should Have User Selectable Alarm Settings• The Machine Should Store At Least 24 Events For Viewing Or Recording.Ecg: • Should Be Able To Monitor Ecg Through 5-Lead Patient Cable • Should Be Able To Display Lead I,Ii,Iii, Avr, Avl, Avf And One Of The Chest Leads• Should Be Able To Monitor Heart Rate From 15-300 Bpmgeneral Specifications• The Machine Should Work On Mains As Well As Rechargeable Battery. • The Device Should Be Manufactured From An Iso Certified Organization• Machine Should Be Supplied With Standard Accessories• System Should Be Easy To Operate With Facility To Give Print Command, Charge And Energy Selection On Both External Paddles And On The Main Unit.• Should Have Upgradable Facility For Masimo Etco2.• Should Have Upgradable Facility For Spo2.• Should Have Upgradable Facility For Nibp.• Should Have Upgradable Facility For Pacer Also. , Multi Para Monitor With P, Nibp, Ecg Facility (Brand - Bpl/Maestros/Drager)) Technical Specifications For Multipara Monitor 1. Multi Parameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,( Oxyset+), Nibp (Suntech) Temperature. 3. Optional Parameter Etco2, Dual Ibp, Agm 4. Should Have 12-Inch Color Lcd Display. 5. Should Have Dual Modes Of Operation: Rotary Knob. 6. Should Display 7 Waveforms Or More 7. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen. 8. Ecg: ? Should Be Able To Monitor Ecg Through 5-Lead Patient Cable ? Should Have Manual St Analysis Window ? Should Detect 20 Arrhythmias And Generate Alarms. ? The Priority Of Arrhythmia Alarms Can Be Configurable ? Should Measure Pvc & Pac ? Should Be Able To Monitor Heart Rate From 10-300 Bpm ? Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etc ? Should Have Pacemaker Detection Facility 9. Respiration: ? Measurement Range Of 0 To 150 Breaths Per Min ? Should Have Gain Selection: ×0.25, ×1, ×2, ×4 ? Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S ? Should Have Apnea Detection Facility ? Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 10. Spo2: ? Should Have Nellcor Technology ? Should Have Measurement Range Of 0~100 % ? Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph ? Should Be Able To Select Sat Sec To Avoid False Alarm 11. Nibp: ? Must Be Of Suntech Medical Technology For Clinical-Grade Blood Pressure Measurement ? Should Have Auto, Manual, And Stat Modes Of Operation For Nibp. ? Should Have A Measuring Range Of 0-280 Mmhg 12. Should Have 2 Channels For Temperature Monitoring 13. Should Have Data Storage Capabilities: O 72 Hours Of Trend Data Storage. 2000 Sets Of Nibp Measurement Data. O 200 Alarm Events O Physiological Alarms Can Be Reviewed With 16 Sec Of Associated Waveform Along With Other Parameter Values. Even Print Out These Waveforms With Optional Recorder O 7 Leads Of Ecg Waveform Disclosure At Least Of 1-Hour O Should Have Facility To Transfer The Trend Data To Usb 14. The Monitor Should Have Drug Dose Calculator And Oxy-Crg View Screens 15. Snapshot Facility With Usb Transfer. 16.Should Have Alarm Settings For All Parameters. 17.Should Have Color Coded Alarms And Alarms Priority Can Be Configurable. 18. Should Have Cns Connectivity Of Same Make. , Fully Functional Automatic Dental Chair With Inbuilt Suction And Compressor (Brand- Confident / Chamundi) Programmable Dental Chair, Unit Fitted With Floor Mount Light With Led(Faro, Maia) Operating Light Having, On/Off And Intensity Control By Non-Touchsensor Monitor Mounting Arm High And Low Vacum Motorized Crs Suction System Autocalvable 2 Nos Beecool Ii Light Cure Cordless-1 No Modular Trolley System Over The Patient Airotor Points- 2 Nos Supreme Micromotor 35,000Rpm With Digital Display Of Speed Three Way Syringe- 1 Nos Supreme Optic Scaler With Five Scaling Tips With Endo Chuck 1 No Ss Instrument Tray X-Ray Viewer Multi Function Foot Control Comfort Dental Operators Stool Compressor Monobloc Oil-Free Medical Grade Airotor Air Compressor 1.5/2 Hp With Radiator Cooler, Condensor, Silicon Column Filter For Moisture, Dust Filter Microbial Filter Fitted On Ms Tank. , Dental Aerotor(Brand - Nsk) Push Button With Led Light , Dental Micromotor Contrangle(Brand - Nsk) Latch Type , Dental Micromotor Straight With Led Light (Brand - Nsk) , Round, Straight Surgical Bur For Straight Hand Piece Micromotor Carbide Burs(Brand - Nsk/Prima) , Round, Straight, Inverted Cone And Tapered Fissure Burs For Aerotor Diamond Fg (Brand- Dent Ark) , Rotary Files Niti Files Sx, S1 S2 F1 F2 And F3 (Brand- Dent Ark /Nsk) , Ultraound Color Doppler System (Brand -Samsung Hs30/ Ge Logiq / Mindray Mx7 (3D,4D)/Bpl) Technicalspecification 1. The Units Should Be Latest State Of The Art Digital Color Doppler With Broadband Beam Forming For Cardiac, Abdominal,Vascular And Ob/Gynapplication. The Models With Following (Or Higher) Specifications Need To Be Quoted. 2. The Machines Should Be Usa Fda And European Ce Certified And Should Be Latest In Technology And Launched In 2016 Or Later. The Manufacturing Company Should Be Iso Certified. 3. They Should Have At Least 750000 Digital Processing Channels For High –Resolution Imaging. 4. Imaging Modes : 2D, M- Mode, Color Flow Imaging, Pulse Doppler, Power Doppler, Continuous Wave Doppler And Directional Color Flow Mapping, 3D/4D Imaging Modes 5. The Machine Should Be Supplied With Dedicated 3D/4D Package 6. The Machines Should Have Facility For Simultaneous Dual/ Duplex/ Triplex Mode Display 7. Tissue Harmonic Imaging Should Be Available On All The Transducers. 9. Machines Should Be Capable Of Advanced Real Time Compound Imaging. 10. Should Have Frame Rate 1500 Fps Or More 11. Scanning Depth Should Be 40 Cms Or More 12. High Dynamic Range Of 250 Db Or More. 13. The Machines Should Have 256 Grey Shades (8 Bit) Or More. 14. One Touch Image Optimization Should Be Available In 2D Mode With One Button Automatic Adjustment Of Tgc And Receiver Gain And Compression Curve Based On The Range Of Detectable Tissue Signals. 15. There Should Be One Button Automatic Adjustment Of Doppler Prf, Baseline, Dynamic Range And Gain In Doppler Mode. 16. Pulsed Wave Doppler Should Be Available On All Imaging Transducers With Adjustable Sample Volume Size, Simultaneous Or Duplex Mode Of Operation, Simultaneous, 2D, Colour Doppler, Pulsed Doppler, High Prf Capability In All Modes Including Duplex And Triplex And Automatic Adjustment Of Scale And Baseline. The System Should Have Option To Adjust The Color Flow Mode For High Or Low Flows In One Touch. 17. Machines Should Support Broad Band/ Wide Band High Density Probes Spanning With Frequency Range From 1-20 Mhz (+/- 1 Mhz). The System Should Support Latest Technology Single Crystal Probe Or Matrix Array Probes For Better Resolution And Penetration. 18. Automatic Doppler Analysis Should Be Available With Automatic Real Time Calculation Of At Least Sixof Following User Selectable Parameters Peak Systolic Velocity End Diastolic Velocity, Mean Diastolic Velocity, Volume Flow, Time Average Mean Velocity, Time Average Peak Velocity, Resistive Index, Pulsatility Index, Systolic/ Diastolic Ratio, Acceleration/ Deceleration Times. 19. The Machine Should Have Up To 500000 Images Storing Facility And Cine Loop Review Facility With Memory Up To Minimum Of 25,000 Frames 20. The Machines Should Have Facility Of Direct Storage And Retrieval Of B/W And Color Images (Both Frozen And Cine Loop) In The Inbuilt Hard Disk Drive. In Built Hard Disk Storage Should Be Equal To Or More Than 1Tband Solid State Device In Addition With Capacity 120Gb. 21. The Machines Should Support Four Or More Transducers With Universal Ports Allowing Any Transducer To Be Connected To Any Port. 22. Machines Should Have A High Resolution Fully Articulating Non-Interlaced Flicker Free, Anti-Glare Led Display Of 21 Inches Or More With Resolution 1,920X 1,080 Or Better.In Addition, The Machine Should Have 10” Or More Touch Control Panel For Easy Access. 23. The System Should Have Image Enhancement Options Like Speckle Reduction, Spatial Compounding And Filtered Tissue Harmonics. The System Should Have Adaptive Blending Color To Maintain The 2D Resolution While Working In Color Mode. 24. Zoom Facility (Upto 8 Times Or More Magnification) With High Resolution Results And Pan Capacity In Both Real Time And Frozen Images. 25. The System Should Have Cd-Dvd And Usb Archival (Dicom And Pc Format).There Should Be 4 Or More Usb Ports. 26. Machine Should Be Offered With The Following Broadband Probes (I) Cardiac Package Along With Adult Phased Array Transducer With Frequency Ranging 1.0 - 5.0Mhz (+/- 1.0Mhz). (Ii) Convex Transducer Frequency Ranging ( C1-6Ct) Mhz. (Iii) Liner Transducer Frequency Ranging (L3-12T ) Mhz (Iv) Tvs Transducer Frequency Ranging (Ec3-10T) 27. Online 1Kva Upsand Color Inkjet Printer 28. Preference Would Be Given To Products Manufactured In India, Japan, Korea, Europe, Us. , Laproscopic Surgery Set With Hysteroscope And Resectoscope (Brand Ethicon/ Mindray Medical Pvt Ltd/ Karl Storz/ Conmed/Olympus) Unit And Camera Head The System Should Have The Full Hd Resolution-1920 X1080 Internal Medical Grade Recorder For Capturing Full Hd Videos And Full Hd Stills With Storage Capability Internal Of 50 Gb Or External Medical Grade Recorder Should Be Provided From The Same Manufacturer. System Should Have The Facility Of Controlling The Recording Device From The Camera Head. Video Scopes Can Be Connected To The Same. The Camera System Should Be Able To Provide With 1080 P Lines For Hd Resolution Image. Technical Specifications: Image Sensor: 1 Xcmos Agc: Microprocessor Controller Weight: 130Gm Focal Length: 16Mm Control Buttons: 3 (2 Of Them Freely Programmable) Input: Keyboard Input For Character Generator. Power Supply:-100-240 Vac 50/60 Hz Certified To: Iec 601-1, 601-2-18, Csa 22.2 No. 601, Ul 2601 And Ce According To Mdd, Protection Class1/Cf 2 High-Definition Medical Grade Monitor Led Crystal Display. Max. Resolution Of 1920X1080. Screen Diagonal - 27Inches Desk Top With Pedestal. Should Have The Facility Of Pip Mode. Accessories External 24Vdc Power Supply, Mains Cord, Pedestal. Certified To: En 60601-1, Protection Class Ipx 1 Led Light Source With Fiber Optic Cable Color Temperatures 6400K External Light Source Light Outlets - 1 Light Intensity Adjustment: - Continuously Adjustable Manually From Light So Should Be Supplied With Light Cable, Diameter 4.8Mm, Length 250Cm. Certified To :- Iec 601-1 & Ul 544 Ce According To Mdd, Protection Class 1/C Telescopes Forward Oblique 30 Degree Telescope, Diameter 10 Mm, Autoclavable, Length Optic Light Transmission Incorporated. Forward Oblique 30 Degree Telescope, Diameter 5 Mm, Autoclavable, Length 2 Optic Light Transmission Incorporated Co2 Insufflator Technical Specifications: Gas Flow: 0-400 L/Min Cv 625 Laprascopy Set Pressure: 0-30 Mmhg (4000Pa). High Flow Mode (0 To 40 L/Min.) Sensitive Mode Pressure 15 Mm Hg & Flow 15 L/Min For Sensitive Application Electronic Control And Colour Touch Screen, Following Data Are Displayed On Touch Screen: -Insufflation Mode. Set Value Pressure (0-30 Mmhg). Current Patient Pressure. Set Value Gas Flow (0-40 L/Min). Current Gas Flow. Gas Consumption (0-999 1). Reusable Insufflation Tube For Co2 Gas Up To Patient Body. High Flow Mode With Flow Performance Up To 40 L/Min. Easy And Intuitive Use With User Friendly Color Touch Screen 7 Inch For Easy And Precise Setting Of Set Values For Pressure And Flow And Of Insufflation Mode, As Well As For Clear Display Of Corresponding Set Values And Actual Values. Optical And Acoustic Alarm Signals In The Event Of Patient Overpressure Should Have Hose Pipe. Equipment Cart From The Same Manufacture Should Be Quoted With 4 Or More Helves Isolation Transformer Co2 Cylinder Holder Laparoscopic Instruments- Detailed Description • Veress Pneumoperitoneum Needle With Spring Blunt Stylet, Luer-Lock, Length 13 Cm & 15 Cm –2 Nos • Trocar, Size 11 Mm, Color Code: Green, Consisting Of: Trocar Only, With Pyramidal Tip Cannula Without Valve, With Insufflation Stop-Cock, Length 10.5 Cm Multifunctional Valve, Three Part Dismantel, With Washers Pack Of 10 – 4 Nos • Trocar, Size 6 Mm, Consisting Of: Trocar Only, With Pyramidal Tip Cannula Without Valve, With Insufflation Stop-Cock, Length 10.5 Cm Multifunctional Valve, Three Part Dismantel With Washers Pack Of 10 – 4 Nos • Reduction Sleeve, 11/5 Mm – 1 Nos • Reducer 11/5 Mm– 1 Nos • Telescope, Diameter 10 Mm, Length 32 Cm, Autoclavable, Variable Direction Of View From 0°-90, Adjustment Knob For Selecting The Desired Direction Of View, Fiber Optic Light Transmission Incorporated- 1 Nos •Injection Needle, Luer-Lock, Diameter 1. 2 Mm, Size 5 Mm, Length 36 Cm - 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 3 6 Cm, Right Angled, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Insert, And Outer Tube, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Long, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting- And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Alligator Jaws, Double Action Jaws, Consisting Of: Plastic Handle Without Ratchet, With Larger Contacact Area, Insert And Outer Tube, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Siz E 5 Mm, Length 36 Cm, With Connector Pin For Unipolar Coagulation, Atraumatic, Jaws With Multiple Teeth, Fenestrated, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Atraumatic, Jaws With Multiple Teeth, Fenestrated, Long, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, 2 X 4 Teeth, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle With Manhes Style With Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Bowel Grasper, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area Outer Tube, Insulated., Three Parts Dismantle 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Cleaning, Single Action Jaws, Atraumatic, Fenestrated, Curved, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet Metal Outer Sheath, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Atraumatic, Fenestrated, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Insert And Outer Tube, Three Part Dismantel. 1 Nos • Three Plece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Heavy, Double Action Jaws, Consisting Of: Plastic Handle, With Manhes Style Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel – 1 Nos • Three Plece Scissor, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Deaning, Double Action Jaws, Curved, Length Of Blades 15 Mm, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Insulated, Without Ratchet Metal Outer Sheath, Insulated Scissors Insert For Use With Trocars Size 6 Mm Three Part Dismantel 1 Nos • Single Use Scissor Insert Pack Of 10 (1X10) 1 Nos • Three Piece Laparoscopic Hook Scissors, Rotating, Size 5 Mm, Length 36 Cm, Jaws Not Crossing With Connector Pin For Unipolar Coagulati On, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Outer Tube, Insert, Three Parts Dismantel 1 Nos • Three Plece Laparoscopic Autoclavable Grasping And Dissecting Forceps, Single Action Jaws, Fenestrated, 360 Degree Rotational Sheath, Size 5 Mm, Length 36 Cm, Long, Ergonomic Metal Handle With Plastic Finger Rings With Larger Contact Area At The Finger Ring To Avoid Pressure Sores, Can Be Dismantled With The Press Of A Button. 1 Nos • Suction And Irrigation Tube, Anti-Reflex Surface With Two-Way Stopcock, For Single Hand Control, Size 5 Mm, Length 36 Cm 1 Nos • Olsen Suction Or Irrigation Tube, With Protection Basket, With Trumpet Valve, Size 10Mm Length 36Cm. 1 Nos • Dissecting-Electrode, L-Shaped, Size 5 Mm, Length 36 Cm, With Connector Pin For Unipolar Coagulation, Consisting Of: Outer Tube, Insulated Plastic Handle Electrode L-Shaped With Trumpet Handle 1 Nos • Coagulating And Dissecting Electrode, L-Shaped, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Working Length 36 Cm 1 Nos • Coagulating And Dissecting Electrode, Spatula-Sheaped, Blunt With Connector Pin For Unipolar Coagulation, Size 5 Mm, Working Length 36 Cm 1 Nos • Macro Needle Holder, Ergonomic Axial Handle With Disengage Able Ratchet, Ratchet Release On The Right Side, Left Curved Jaws, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm 1 Nos • Macro Needle Holder, Ergonomic Pistol Handle With Disengage Able Ratchet, Ratchet Release On The Right Side, Right Curved Jaws, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm 1 Nos • Dismantling Needle Holder, Ergonomic Pistol Grip With Disengage Able Ratchet, Ratchet Release On The Left Side, Jaws Curved Left, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm Consisting Of: Insert, Outer Tube, Handle 1 Nos • Unipolar Hf Cord With 4Mm Banana Plug And Length 300 Cm 1 Nos • Clip Applicator, For Use With Ethicon Titanium-Clips Lt-300 (Medium Large), Dismantling, Rotating, With Ratchet To Lock The Jaw Part Holding The Clip, Size 10 Mm, Length 36 Cm, Consisting Of: Metal Handle, With Ratchet Metal Outer Tube Insert, Three Part Dismantel, 1 Nos • Claw Forceps, Rotating, Size 10 Mm, Length 36 Cm, 2 X 3 Teeth, Single Action Jaws, Consisting Of: Metal Handle, With Manhes Style Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Claw Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, 2 X 3 Teeth, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area Outer Tube 1 Nos • Rotatable Bipolar Grasping Forceps, Rotating, Dismantling, With Connector Pin For Bipolar Coagulation, Double Action Jaws, Especially Suitable For Dissection, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet, Color Code: Light Blue Outer Sheath Forceps Insert, Three Part Dismantel. – 1Nos • Rotatable Bipolar Grasping Forceps, Rotating, Dismantling, With Connector Pin For Bipolar Coagulation, Double Action Jaws, Fine Atraumatic Serration, Fenestrated, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet, Color Code: Light Blue Outer Sheath Forceps Insert, Three Part Dismantel. – 1 Nos • Bipolar Hf Connecting Cable Length 300 Cm, Compatible With All Standard Cauteries – 1 Nos • Fascial Closure Instrument For Sub Cutaneous Ligature Of Trocar Incisions – 1 Nos • Myoma Fixation Instrument, Screw Shaped, 5 Mm. – 1Nos • Dismantling Fan Retractor, Distendable, Size 5 Mm, Length 36 Cm.- 1 Nos • High Frequency Needle, For Splitting And Coagulation, Insulated, Retractable, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 31 Cm. 1 Nos • Single Use Scissor Insert Pack Of 10 (1X10) - 1 Nos • Uterine Manipulator: Uterine Manipulator For Providing Tissue Tension Needed For Anatomical Surgery. The Manipulator Should Have Application In Tlh, Lash, Lavh And Hysterectomies For Malignant Pathologies 1 Nos • Sterilization Tray For 2 Telescopes (Same Manufacturer) • Sterilization Tray For Instruments (Same Manufacturer) Hysteroscopy Set Hysteroscope Sheath For Diagonostic Continuous Irrigation Size 6.1-6.3Mm Outer Sheath And 5.1-5.3 Mm Inner Sheath For Use With 4Mm Hysteroscope Telescope. Hysteroscope Sheath For Operative Continuous Irrigation Size 5.9-6.1Mm Outer Sheath With Operating Channel 5Fr, Leur Lock Adaptor And 5.3-5.5Mm Inner Sheath For Use With 4Mm Hysteroscope Telescope. With Stopcock & Leur Lock Adaptor And Inflow And Outflow Channe Semi Rigid Instruments For Use With Operating Hysteroscope Scissors Semi Rigid, Blunt Tips, 5 Fr., Length 36-40Cm, Single Action Jaws Scissors Semi Rigid, Pointed Jaws, 5 Fr., Length 36-40Cm, Single Action Jaws, Semi-Rigid Biopsy- And Grasping Forceps Semi Rigid, 5 Fr., Length 36-40Cm, Double Action Jaws Tenaculam Grasping Forceps Semi Rigid, 5 Fr., Length 36-40Cm, Double Action Jaws Bipolar Vaporization Electrode, Semirigid, 5 Fr., Needle Electrode Angled 90°, Length 42Cm Bipolar High Frequency, Should Fit In Most Of The Standard Electrosurgical Unit Having Bana Plug One Side, Length Should Be Not Less Than 250Cm Telescope 12, Enlarged View, Diameter 4 Mm, Length 30 Cm, Autoclavable, Fiber Optic Light Transmission Incorporated Bipolar Working Element To Be Used With 26 Fr Resectoscope Sheath: Motion By Means Of A Spring. The Thumb Support Is Movable. Return Of The Loop Is Control By The Thumb And In Rest Position The Electrode Should Rest Inside The Operating Sheath, To Be Used With 4Mm Hysteroscopy Telescope. Should Work In Saline Bipolar Cutting Loop 24 Fr Should Work In Saline Cutting Electrode 24Fr, Bipolar, Pointed, Should Work In Saline Coagulating Electrode 24Fr, Bipolar, Ball End Should Work In Saline Continuous Flow Resectoscope Sheath 26 Fr., For Bi-Polar, Including Connection Tubes For And Outflow, 2 Luer-Lock Adaptors, 26Fr, Oblique Beak, Rotating Inner Tube, With Ceramic Insulation, For Use With Working Element. Should Work In Saline Obturator, For Use With The Resectoscope Sheath. Fluid Management System (Irrigation & Suction Unit) Pressure Regulated Suction And Irrigation System For Use In Laparoscopy And Gynaecology Unit Should Have Touch Screen As User Interface. Unit Should Have Feature Of Automatically Fixing Maximum Parameters For Laparoscopy And Hysteroscopy Mode By The Choice Of Tubing Unit Should Have Feature Of Simultaneous Display Of Set Values And Actual Values Enabling User For Continuous Monitoring Of Suction And Irrigation Parameters Unit Should Have Feature Of Use Of Disposable/Reusable Cassette Tubing Set For Laparoscopy/Hysteroscopy Procedures. Unit Should Be Supplied With Glass Suction Bottle 5 Lite Unit Should Have Pressure Settings: Hysteroscopy Mode: 0-200 Mmhg Laparoscopy Mode: 100/300/500 Mmhg Unit Should Have Flow Settings: Hysteroscopy Mode: 200/400/600 Ml/Min Laparoscopy Mode: 0-1300Ml/Min Suction Pressure Regulated: Hysteroscopy Mode: 0.1-(-)0.8Bar (-80Kpa) Laparoscopy Mode: 0.1-(-)0.8Bar(-80Kpa) Power Supply: 100-240Vac, 50/60Hz Certified To: Iec 601-1, Ce Nach Mdd Certified To: Iec 601-1, Ce Acc. To Mdd Note: - All The Above Items Should Be Usfda And European Ce Certified And From Same Manufacturer For Better Compatibility And Maintenance , Integrated Electrosurgical Unit And Vessel Sealer Brand -Ensurge/ Hti Digital / Kls Martin / Enertech/Shalya Specifications For Integrated Electrosurgical Unit And Vessel Sealer 1) Advanced Electro Surgical Unit With Vessel Sealing System Have Mono Polar Cut & Coagulation, Bipolar And Vessel Sealing Technology, All Integrated In Single System 2) Type Of Display Should Be Lcd Touch Screen 3) Display Size Should Be 5” Or More 4) Unit Should Have Microprocessor-Controlled Tissue Feedback Technology. 5) The System Should Have Capability To Convert Electrical Energy To Radio Frequency Energy Thus Providing Radio-Frequency Seal 6) Number Of Tissues Sensed Per Sec Should Be 4000 Or Higher 7) Vessel Fusion System Must Be Able To Seal Artery, Veins Along With Tissue Bundle Up To & Including 7Mm In Diameter & Sealed Vessels Should Be Able To Withstand At Least 3 Times The Systolic Blood Pressure. 8) Low Frequency Leakage Should Be 50 Or Higher (In Ma) 9) High Frequency Leakage (Rf) Must Be Less Than 100Ma In Mono Polar And Vessel Sealing Mode And Less Than 70Ma In Bipolar Mode 10) Should Be Provided With Rs 232 Data Input Port For Software Upgrade Facility 11) System Must Have Recall Facility To Recall The Last Setting Used By User Before Turning Off The Power Directly Or Through User Programs. User Can Use Pen Drive With Their Setting To Recall The Setting Saved By Them. 12) System Should Have Bipolar Resection Including Under Water Cutting. 13) The System Should Be Provided With Twin Monopolar Socket (Only One Socket To Be Activated At A Time) With Independent Power Setting 14) 5 Or More Numbers Of Cutting Modes Available In Monopolar 15) Maximum Power Should Be 400W Or Higher 16) Maximum Power Of Blend Mode For Cutting With Homeostasis Should Be Not Less Than 250W 17) Fulgurate/Forced Mode, Spray Mode, Soft Mode Of Monopolar Coagulation Should Be Available. 18) Unit Should Be Supplied With 4 Or More Nos. Of Monopolar Coagulation Modes 19) Coagulation Mode Power (Monopolar) Should Be 150W Or Higher 20) Coagulation Mode Power (Bipolar) Should Be 120W Or Higher 21) Number Of Bipolar Cutting Modes Should Be Or Greater Than 5 22) Maximum Power For Ligation Not Less Than 100W 23) Maximum Power For Resection Not More Than 300W 24) Equipment Should Have On Screen Review Of Error Codes And Diagnostics. 25) System Should Have Patient Plate Contact Quality Monitoring System Giving Audio-Visual Alarm And Deactivating Output If Contact Between Patient And Patient Plate Is Not Proper To Eliminate The Risk Of Patient Burns. It Should Be Mandatory, Should Have Contact Quality Monitoring With Split Style Patient Return Electrode And Deactivates Output If Contact Between Patient And Patient Return Electrode Is Not Proper To Eliminate The Risk Of Patient Burns, Manufacturing By Same Oem 26) Auto Bipolar Start And Stop Along With User Configurable Auto Start Facility Should Be Available 27) Power Output Of Vessel Sealing System (Vss) Not More Than 150W 28) Vessel Sealing System Should Be Able To Seal Vessels Or Tissue Bundles Faster Than Any Conventional Devices (Preferably Within 2-4 Seconds) 29) Product Should Be Ce Certified (4 Digit Notified Body). 30) It Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification & Iso 9001: 2008 & Iso 13485:2003 Certified Company. 31) Warranty Of The Unit Should Be 5 Years 32) It Should Be Supplied With All Following Accessories, Should Be Reusable And Autoclavable: - O Patient Return Electrode --- 1 No. O Cable For Return Electrode --- 1No. O Hand Switching Pencil --- 1 No. O Foot Switching Pencil --- 1 No. O Double Pedal Footswitch With Toggle Function (Common/Individual For Monopolar, Bipolar And Vessel Sealing) - 3 No. O Universal Adaptor --- 1 No. O Bipolar Forceps --- 1 No. O Cable For Bipolar Forceps --- 1 Nos. O Set Of Electrode (Angled, Ball And Needle) ------ 1No. O Reusable Sealing Clamp With Cable--- 1 No. O Curved Jaw Vessel Sealer 5 Mm, 32 To 37 Cm -- 1 No. O Autoclavable Reusable Cutting Instrument – 1 No. Additional Terms & Conditions: 1. Vessel Sealing Laparoscopy Instruments Should Have Both Hand And Foot Activation Mode And Should Be Eu Ce (4 Digit Notified Body Certified) Or Usfda Approved. 2. All Sockets Should Be Of Blinking Light Type When In Use To Identify The Used Mode. 3. R.F. Frequency Should Be In Between 350-500Khz For All Modes. 4. It Should Have Bipolar Rf Scalpel Mode For Dissection & Desiccation. Rf Bipolar Scalpel Instruments Should Have Hand Control Button For Coagulation & Cut. 5. Equipment Should Be Usfda Approved/ Eu Ce (4 Digit Notified Body Certified). It Should Have Iec-60601-1- 1, Iec 60601-2-2 Safety And Des , Ctg Machine Brand - Bpl/Maestros/Bistos Specification Foetal Monitor With Display And Printer Should Have 12.1” High Resolution Colour Tft Display With Tiltable Screen For Better Viewing. Should Display Fhr, Toco, Foetal Movementin Numeric Values . Should Display 2 X Fhr And Toco Graphs In Different Colours. Should Have The Facility For Data Save With Play Back & Print Facility Should Have Facility To Monitor Information Of Last 25 Hours Should Have Special High Sensitive Watertight Probe For Better Durability Should Have The Low Ultrasound Power For The Safety Of The Foetus Should Have Automatic Foetal Movement Detection Should Have Event Marking Facility By Mother And User Thermal Printer With Minimum 152Mm Paper Width Is Essential For Broader Printouts Standard Configuration Should Be Fhr, Toco, And Foetal Movement Should Have Volume Control For Fhr Beep Sound And Alarm. Should Have Alarm Setting For Weight Should Be Less Than 4 Kg For Easy Portability. Should Have Foetal Stimulator Built In To Fhr Probe And Activation Key Should Be There On The Front Panel. Stimulation Should Be Recorded On The Recording Paper And Should Be Displayed On The Screen. Built In Rechargeable Li-On Battery For Backup Should Work With Input 200 To 240Vac 50 Hzsupply Central Monitoring System Software Upgradability Should Be Possible (Optional) Should Be Supplied With The Following Standard Accessories: Power Cord- 01 Fhr Probes – 01 Nos Toco Probe -01 Patient Event Marker Belts – 02 Nos Gel – 1 Bottle Thermal Paper- 02 No , Digital Video Colposcope Brand - Bpl/Maestros/Bistos Specification 1. Should Have Led Cold Lighting System Reproduces An Original View Of Tissue. 2. Led Lights Are Replaceable. 3. Should Have Advanced And Fast Auto-Focusing System To Ensure Clear Image. 4. Should Have Remote Capture Control And User-Friendly Keyboard Layout For One Handed Operation. 5. Should Have Electronic Green Filter That Enhances Vascular Image Display Without Compromise Of Illumination. 6. Should Have Working Distance Of 6.7 - 11.8 (170 - 300 Mm). 7. Should Have Magnification Of 1X - 36X. 8. Should Have Resolution Of 3,80,000 Pixels Or More 9. Should Have Horizontal Resolution Of > 470 Lines. 10. Should Have Field Of View Of 0.4 - 5.9 (10 - 150 Mm). 11. Signal/Noise Ratio Should Be = 50 Db. 12. Should Have Signal Output Of S-Video, Pal/Ntsc. 13. Should Have Acetic Acid And Iodine Reaction Test Timer To Precisely Detect Low/High Grade Cin. 14. Should Have Real-Time Display Of Magnification. 15. Should Have Powerful Colposcopic Findings Gallery For Comparison Analysis. 16. Should Have R-Way Evaluation Program Supports Cervical Disease Diagnosis Guidance For Clinical Users. 17. Should Have Dicom 3.0 Supportive. 18. Should Be Manufactured By An Iso Certified Company , Vessel Sealing Device For Open Surgery Shaft Length-23Cm Curved Tip (Box Of 6)(A) Curved Jaw Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology. Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A} Curve Jaw Vesselsealer B) Should Be Able To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. C) Sealing Should Withstand 3 Times Systolic Pressure. D) Scaling Length 20 Mm; Cutting Length 18 Mm, Shaft Length 23 Cm; Shaft Diameter 5 Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. Technical Specification For , Vessel Sealing Laparoscopic Surgery, Shaft Diameter-5Mm, Length-37 Cm Jaw Type Curved Jaw Double Action With Contoured Tips, Shaft Rotation 350 Degrees, Jaw Surface-Textured Ceramic Stops.Jaw Aperture-13Mm Seal Plate Length- 20.3(Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Blunt Tip Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Sealing Length 20 Mm; Cutting Length 18 Mm, Shaft Length 37 Cm D) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness:Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. E) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Instrument For Open Surgery, Instrument Length 20.6Cm-21 Cm, Curved Jaw, Hand And Foot Switching(Box Of 6). Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Exact Open Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Instrument Length Should Be 21 Cm. D) Curved Jaw In 28 Degrees, Seal Length 19.3Mm, Cut Length: 18.5Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Device Laparoscopic Surgery. Shaft Diameter-5 Mm, Maryland Jaw Curved Device Length 37Cm (Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Curved Jaw Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec B) Sealing Should Withstand 3 Times Systolic Pressure. Scaling Length 20 Mm; Cutting Length 18 Mm, Shaft Length 37 Cm; Shaft Diameter 5 Mm C) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation D) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Device For Open Surgery With Shaft Length 18.8 Cm, Jaw Type-Curved Jaw (Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Small Jaw Open Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Instrument Length Should Be 18.8 Cm. D) Curved Jaw In 28 Degrees, Seal Length 16.5Mm, Cut Length: 15.5Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Ethelene Oxide Sterlization Machine ( Brand - Steri Techno Fab/ Map Industries) 1) Eto Gas Sterilizer Should Be Fully Automatic Type With Software-Controlled Operation System For Low Temperature Sterilization Of Heat And Moisture Sensitive Medical And Surgical Items. 2) The Chamber Should Be Preferably Rectangular With Capacity Of 250 Litters Or 9 Cu. Ft. & Dimension 48”(L) X18”(W)X18”(H). 3) The Operating System Should Be Programming Logical Controller Based And Should Have Touch Screen Human Machine Interface From Where User Should Operate And Observe The Cycle . 4) The Inner Surface Should Be Smoothly Finished To Minimize Gas Deposits. 5) Manufacturer Should Provide The Test Report To Prove Conformity To Specification And Ability Of Eto Unit To Achieve Complete Pathological/Microbiological Elimination. The Test Of Report Has To Be Attached With Technical Bid Document. 6) Surface Heaters Should Mount On The Chamber For Uniform Temperature In Chamber Throughout Cycle. 7) Less Noisy And Vibration Proof Vacuum Generator Should Be Provided For Vacuum Instead Of Vacuum Pump. 8) The Machine Should Be Provided With Plc Based Automation Along With Lcd Hmi Which Allows The Operator For: (A) Change And Set The Parameters (B) Run The Cycle According To Pre-Selected Cycles. (C) Monitor Various Phases / Individual Parameters During The Process. (D) View On/Off Status Of The Various Components Of The Machine While The Cycle Is In Progress. 9) It Should Have Password Protection For Unauthorized Access & Analogue Input Of Process Pressure/Vacuum. 10) It Should Have Digital/Analogue Input For Temperature & Temperature Should Be Indicated In The Sterilization Area, By The Use Of A Temperature Sensor. 11) One Pressure/Vacuum Sensor For Display Of The Current Pressure/Vacuum, That The Load Should Be Subjected To, At All Times During The Process. 12) The Software Should Provide & Maintains Total Records Required For Process Parameters During The Sterilization Cycle. These Records Are Necessary For Meeting Ce Or En 1422 Norms Of Sterilization. 13) All The Fittings For The Accessories And The Main Vessel Should Be Fabricated From Ss 304 Stainless Steel. All The Valves Used In The Process Lines Should Be Ss 304/Brass/Teflon Construction Ball Valves. (All Standard Makes) 14) Pressure Testing And Vacuum Testing As Per Specified Standards. (1.5 Times The Working Pressure) 15) Automatic Operations As Well As Manual Operations In Case Of Technical Problems Should Be In Plc/Hmi. 16) Machine Should Not Open During Sterilization Process, It Should Be Open Only After Complete Cycle Of Sterilization. 17) It Should Be Plc Based Automation System. Plc Should Be Honeywell Or Siemens. System Should Be 21 Cfr Compliances. 18) Automation Should Be 7’’ Touch Screen Display Of Schneider Or Proface Or Equivalent. 19) The Construction Of Chamber Should Be Of Ss316 Grade Stainless Steel. 20) There Should Be Interlocks With Door Mechanism So Cycle Should Start Only After Closing Of Door. 21) Cartridge Puncture Operation Should Be Automatic Into The Chamber No Need Of Manual Puncturing. 22) In Case Of Cartridge Puncture There Should Be Alarm System. 23) One Complete Cycle Should Be Containing All Phases. Time Based Parameter Should Be Mention In Non-Editable Data Sheet. 24) Temperature, Pressure, Humidity, And Other Parameters Should Be Display In Hmi Screen. 25) It Should Be Noise Proof And Vibration Proof Vacuum Generator Should Be Provided For Vacuum Instead Of Vacuum Pump. 26) It Should Be In Built Aeration Phase To Remove Residual Gas Out From Sterile Item. 27) Pre-Requisite Sequence Phases Should Define To Run Cycle In Auto Mode. 28) Pre-Sterilization Phases Should Define To Create Proper Condition For Sterilization (I.E. Humidity& Temperature). 29) Post-Sterilization Phases Should Define To Remove Residual Gas From The Product. 30) Machine Should Have Manual Override Operating Facility. 31) Accessories Needs To Be Supplied With Machine: - ? Suitable Air Compressor Of 1 Hp Capacity. Air Compressor Should Be Oil Free And Less Noisy As Compared To The Traditional Oil-Based Compressor. ? 1 Nos Wire Mesh Type Basket For Loading & Un-Loading Of Sterilization Materials. ? Manual Sealing Machine Suitable Medical Use Sealing. Machine Should Operate On 240 V/50 Hz Operated And Make In India Product. Eto Gas Cartridge Of 1 0 0 Grams- 1 0 Nos. Eto Cartridge Should Be Of Same Make Of Machine. Bidder Must Have To Attach Msds Sheet Of Eto Gas Cartridge With Bid Document. 32) The Manufacturer Shall Have Below Listed Certification To Prove His Eligibility And Copy Of The Certificates Should Be Enclosed With The Offer. ? Iso 9001:2015 For Quality Management System. ? Ce Certificate For Eto Sterilizer & Eto Cartridge Compliance With The Requirement Of Directive Council Directive On Medical Devices 93/42/Eec As Amended 2007/47/Ec. ? Quality Management System For Medical Devices Iso 13485:2016 For Eto Sterilizer & Eto Cartridge. ? Risk Management To Medical Devices Iso 14971:2007 For Eto Sterilizer & Eto Cartridge. ? Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use - Part 2-040: Requirements For Sterilizers And Washer Disinfectors Used To Treat Medical Materials Iec 610102-040:2020 & Iec 61010-1- 040:2020. ? As Eto Gas Toxic And Carcinogenic Properties Environment Management System Certificate. ? Medical Electrical Equipment Iec– Part 1-2: Requirement For The Basic Safety And Essential Performance Of Multifunction Patient Monitoring Equipment. ? Iso 45001:2018 For Occupational Health And Safety Management System. ? Iso 20857:2010 And Rohs Directive (2011/65/Eu) On The Restriction Of Use Of Certain Hazardous Substances In Electrical And Electronic Equipment. ? Fda & Who-Gmp Certificates To Prove Standard Of Manufacturing Practice , Ot Light ( Brand - Shalya/Mattrix/Surgident) Description Of Function Led Surgical Lights Illuminate The Surgical Site For Optical Visualization Of Small Low Contrast Objects At Verifying Depths In Incisions And Body Cavities. 1. General Requirements 1.1. The Light Shall Adopt Led Technology To Create A Homogenous Light Patch Without Emitting Any Infrared Rays. 1.2. The Light System Shall Be Dual Light Heads, One Major And One Satellite. 1.3. Light Should Have Electronic Focusing From Control Panels Without Any Motorized Or Mechanical Movement Of Light Panels. 1.4. All Dome Should Have 2 Colour Led Lamps, White (Cool White) & Amber (Warm White) To Achieve High Cri And Get The Required Shade Of Light As Per Different Surgical Requirements. 1.5. High Power Leds Of 5Watts & Above Should Be Used To Provide High Lumen To Watt Ratio Which Leads To Lesser Energy Consumption And Low Heat At Surgical Area <2 Deg. 1.6. Lights Should Have Higher Watts Leds To Achieve High Lumen To Watt Ratio Which Leads To Lesser Energy Consumption And Low Heat At Surgical Area. 1.7. Pulse Width Modulation-Controlled Led Driving To Ensure Less Heating Of Led Which Increases Life Of Leds And No Change In Light Colour Output And Light Colour Temperature Throughout Life. 1.8. The Major System Shall With Automatic Illumination Control System With Sensors On The Light Head. When Some Part Of Led Is Masked By Surgeon’S Head Or Shoulders, The Remaining Led’S Will Become Brighter Automatically To Compensate For The Losing Illumination. 1.9. Light Intensity Shall Be Adjustable Between 30% -100% And Should Have Low Intensity Light For Endoscopy Mode. Light Intensity, Light Field Diameter And Color Temperature Should Be Controlled From Electronic Touch Control Panel Mounted On Light Arm And Wireless Wall Mount Electronic Touch Control Panel. It Should Also Have Provision To Control The Intensity, Electronic Focus, Depth From Sterile Field Though Capacitive Touch Control Handles. 1.10. The Light Head Shall Be Of Petalled / Winged Shape To Avoid Obstruction To Laminar Flow On Surgical Field. 1.11. The Color Temperature Shall Be Synchronized & Controlled By Either Light Head Control Panel. 1.12. The Light Shall Be Mountable To Ceiling From Single Center With 360-Degree Rotation Of All Arms. Spring Arms Shall Be Rotatable At Least 360 Degrees Around Its Own Axis. Each Dome Head Should Be Rotatable With 360 Degree At Connecting Joint With Spring Arm And At Least 300 Degrees Around Its Own Axis. This Feature Should Be Applicable With A Camera Mounted Dome Also. 1.13. The Maximum Movement Angle Of The Spring Arm Shall Be At Least Up 45°And Down 50 1.14. The Thickness Of The Light Head Shall Be No More Than 70 Mm. 1.15. Each Led Shall Be Replaceable Individually To Save Cost In Case Of Failure, Instead Of Replacing The Module With Several Leds. 1.16. The Surgical Light Should Be Complete With All Components For Celling Mount And Electrical Feed-In, Including Finalized Installation. 1.17. Detachable & Auto Cleavable Handle (3 Nos.) For Each Light Should Be Provided. 2. Technical Requirements Of Both Domes: 2.1 It Should Have 2 Colour Led Lamps, White ( Cool White) & Amber( Warm White) 2.2 The Central Illuminance Should Be 160,000 Lux 2.3 Light Field Diameter Should Be Adjustable From 150Mm To 300Mm 2.4 D10: 300Mm & D50 :160Mm 2.5 Color Temperature (K), Adjustable From 3500-5000K 2.6 Color Rendering Index Ra Should Be 95 Or More And R9 Should Be 93 Or More 2.7 Depth Of Illumination (L1+L2) As Per Iec 60601-2-41 (Ver 2003) Should Be 650Mm And As Per Iec 60601-2-41 (Ver 2008) Should Be 1200Mm. 2.8 Dimming Range Should Be Between 25-100% 2.9 Endoscopy Mode Illumination Should Be Less Than 5% Of 160,000 Lux 2.10 Number Of Led Bulbs The Light Head Should Not Be More Than 70 2.11 Led Service Life Should Be Minimum 60000Hrs 2.12 Light Head Dimension Should Be 700Mm (=/- 20Mm) 2.13 Max. Power Consumption Of All Light Sources Should Be Less Than 100W At Maximum Setting. 2.14 Power Supply Should Be 100-240V Ac, 50-60Hz 2.15 One Dome Should Be Ready For The Wireless Camera Attachment. 3.Standards • Iso 9001:2008 • Iso 13485:2003, • European Ce With 4 Digit Notified Body / Eu Ce With Eu Free Sale Certificate /Us Fda Registered . • Should Compliance With: Iec 60601-1, Iec 60601-2, Iec 60601-2-41, Certificate From Any Nabl Accredited Lab / Any Lab From Country Of Origin For Imported Brands , Suction Machine (Electrical) (Brand -Supreme / Goley) Type: Electrical Pump Type: Oil Immersed Rotary Vane Capacity: High Vacuum Voltage: 220 Vac, 50 Hz, 1 Ph Number Of Wheels: 04 (Antistatic) Air Flow: 35 Ltrs/Min Current: 1.8A Noise (Decibel): 30~35 Dba Power Consumption: 370W Weight: 25 Kgs Flow Rate: 35 Lpm Vacuum Gauge: 100Mm Reservoir Volume: 5000Ml Tubing: Non-Collapsible Suction Tubing Max Vacuum: -720Mmhg Motor:½Hp, Fhp 100% Copper Winding Rpm: 1440 Jars: Polycarbonate 2X2.5 Liters Capacity Filter: Bacterial Filter Autoclavable /Reusable Suction Machine Should Be Is I Marked , Fully Automated Biochemistry Analyser Brand (Erba Transia/ Meril) Random Access System With Stat Capability. Analytical Principle Spectrophotometry & Photometry, Turbidometry Principles. Assay Type End Point, Rate, Fixed Point, Kinetic, Ise (Optional). On Board Parameter - Present. Programmable Tests - Present. On Board Cooling For Reagent Present. Through Put - 200 Test/Hour Or More, Continuous Loading Facility. Sample Types Serum, Plasma, Urine & Other Body Fluids. Sample Volume 0-70 Micro Litres (Approx). Sample Quality Analysis, Clot Detection & Probe Crash Protection - Present. Reagent Volume 10 Microlitre To 300 Microlitre (Approx.). Total Reaction Volume 90 Microlitre To 350 Microlitre. Reaction Cuvettes - Permanent Glass Cuvettes With On Board Laundry. Possibility Of Replacement Of Individual Cuvette. Photometric Range 0-3.0 Od. 15. Wavelength-340-800 With Minimum & Standard Wavelengths (340, 405, 505, 546, 578, 600, 700 Nm) Calibration Autocalibration, Cooled Calibration Position, History Of Graphical Calibration Data Stored. Quality Control At Minimum 4 Level Qc Plot Westgard Rules, Twin Plot, Levey Jennings Graph, Cooled Qc Position. Data Storage Of Patient Present Proper System Of Storage Minimum Water Consumption. Warranty 5 Years Warranty Power Back Up Facility For Instrument. Autopipettes To Be Provided With Instrument 10 Micro Litre (Fixed) 01 Nos. 1000 Micro Litre (Fixed) 01 Nos. 0-100 Micro Litre (Variable) 01 Nos. 0-500 Micro Litre (Variable) 01 Nos. 100-1000 Micro Litre (Variable) 01 Nos. Demo Kit With Instrument Reagents Kits Provided With Instrument: Creatinine, Urea Uric Acid, Triglyceride, Sugar Cholesterol, Tp, Albumin, Sgpt, Sgot, Alkaline Phosphatase, Bilirubin Instrument: Usfda Registered And Ce Ivd Approved , Cbc Machine Brand -(Accurex / Erba/ Meril) Measurement Principle Electrical Impedance For Counting Rbc Wsc & Plateletscolorimetric Estimation Of Hgb At 540 Nm Parameterswbc, Ly#, Mid, Gr, Ly%, Mid%, Gr, Rbc, Hgb, Hct, Mcv, Mch, Mchc, Rdw-Cv, Rdw-Sd, Plt, Mpv, Pdw, Pct, P-Lcr, P-Lcc Throughput- 60 Samples/Hour Micro-Aperturewbc: 100 ?M Rbc/Plt:68 ?M Sample Typewhole Blood Or Pre-Diluted Sample Sample Volumewhole Blood (Venous Blood): 10 ?Lpre-Diluent (Capillary Blood) : 20 ?L Chamberdual Chamber: Rbc/Platelets & Wbc/Hgb Reagents- 3 Reagent System: Diluent, Detergent & Lyse (Non-Cyanide) Measurement Range Linearity Range Acceptable Limits Wbc0x10/L-10.0×109/L<= Plus/Minus 0.3 * 10 ^ 9 / L 10.1×109/L-99.9×109/L 0X102/L-1.00×102/L <= (Plus/Minus 5)%<= Plus/Minus 0.05 * 10 ^ 12 / L Rbc 1.01X102/L-9.99X102/L<= (Plus/Minus 5)% Quality Control - 4 Qc Options: L-J, X-B, X-R & X Qc Graphs Plotted With 31 Data Points Data Memory - Upto 100,000 (With Histogram) Display - 10.4 Inch Color Lcd With 640 * 480 Resolution Printer Built-In Thermal Printer Interface:Support Rs-232C, Standard Network Port And Usb; Keyboard And Mouse Operating Environment - Temperature: 15°C-35°C Electrical Specification-Fuse Specification: 250V/3A Humidity: = 85% Rh Frequency: 50/60 Hz Low: 1 X 3Ml/Normal: 1 X 3Ml/High: 1X3 Ml , Sthetoscope Brand- Bpl/Littman , Pulse Oxymeter Brand - Dr Trust /Beurer/ Bpl Specification Finger Chamber With Smart Spring System Accommodates A Wide Range Of Finger Sizes Pop-Up Menu To Setup Alarm Limits For Spo2 And Pulse Rate Low Battery Indicator Pule Rate: Yes Auto Power-Off: Yes Bright, Large Display For Better Visibility In Daylight Anti-Movement Feature Sturdy, Portable And Light-Weight Very Easy To Operate With Single Switch Operation Warranty ( Only Checking Warranty ) , Nebulizer Machine ( Brand -Bpl/Dr Trust) Operation Mode Table Top Size Compact Application Clinical Purpose, Hospital Medicine Cup Capacity 50 Ml Particle Diameter 1-5 Um , Pns ( Pereferal Nerve Stimulator For Nerver Block) Brand- B Braun / Vygon Sas/ Stimuplex Hns/2 Should Be Suitable To Identify Peripheral Nerves And Giving Percutaneous Stimulation In Neuro Muscular Block. - Should Have A Percutaneous Monopolar/Bipolar Stimulating Handle For Localization Of Nerves Without Puncturing The Nerve Which Should Be Autoclavable. - Should Have Selectable Stimulation Intensity Ranging From 0-60Ma In Steps 0.1Ma With Stimulating Handle And Stimulation Impulse Width From 0.3Ms, 0.5Ms And1.0Ms - Should Continuously Measure & Display Actual Current Passing Through The Patient And Selected Current -Should Have Pause Function To Interrupt Stimulation Without Delivering Impulses Test Function -Should Automatically Switch Off With A Acoustic Warning If Not Operated Over A Period Of 20 Mins -Should Have Lcd Display For Stimulation Current, Impulse Pattern, Pulse Width, Impulse Amplitude. - Should Have Analog And Digital Display Of Selected Current And Actual Current. - Should Have Membrane Touch Pads For Choosing Stimulation Function -Should Be Small (Pocket Size) & Light Weight. Should Be Ce Certified Or Usfda Certified , Nerve Locator With Needle Brand- B Braun / Vygon Sas/ Stimuplex Hns/2 Separate Output For Nerve Stimulator - Mapper And Locator For Safety. Automatic Switch Over From Mains Power Adaptor To Rechargeable 9Vbattery With Low Battery Warning Indicator. Feather-Touch Keypad For Easy Operation, Simple Setting And Extended Reliability. Variable Current Range As Per The Selected Mode(Impedane:0 To 5 Kohm). User Programmable Pulse Width And Frequency. Alphanumeric Lcd Display With Back Light. Automatic Shutdown For Power Saving. Audio And Back Light On-Off Option. Alarm: Audio-Visual-Alarm Is Activated If Flow Of Oxygen Falls Below 1Lpm. , Percussion Hammer Ss 304 , Tuning Fork 128 Hz Satinless Steel , Laryngoscope A Laryngoscope Is A Device Used In Medical Procedures To Visualize The Trachea By Inserting A Blade With A Small Light Into The Patients Mouth , Oxygen Concentrator Brand- Philips/Bpl/Deck&Mount 1. Flow Rate :-0-5L/Min 2. Purity 93+3% 3. Outlet Pressure(Mpa):-0.04-0.07 4. Sound Level :-<50 Dba , High Flow Nasal O2 Cannula (Brand- Drager / Niceneotech ) High-Flow Nasal Oxygen (Hfno) Therapy Delivers Heated And Humidified Oxygen At High Flow Rates (Up To 60 Liters Per Minute) Through A Nasal Cannula , Electric Needle And Syringe Destroyer Hub Cutter Stainless Steel With Auto-Cut Protection , Clinical Thermometer(Digital) , Medical Labrotary Refrigrator ( Brand- Remi / Vav Intruments) Capacity 600 Litres Temperature Range 2°C To 8°C Internal Configuration Adjustable Shelves And Storage Bins For Optimal Space Utilization Cooling Type Uniform Cooling For Consistent Temperature Distribution Display & Controls Digital Display With User-Friendly Controls Power Supply Energy-Efficient Performance , Refrigrator Domestic Single Door Godrej/ Kelvinator/ Bluestar Capacity 200 Litres To 265 Liters Temperature Range 2°C To 8°C , Wieghing Scale Mannual , Knee Hammer , Sahli,S Heamoglobinometer , Artery Forcef Staright 6 (Brand - Jj Instrument) , Double Hook Retractor Standard Size (Brand - Jj Instrument) , B.P Handleno 3 (Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 4 Mosquito(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 6 Medium(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 8 Long(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 9 Long(Brand - Jj Instrument) , Allies Forceps Big (Brand - Jj Instrument) , Allies Forceps Medium (Brand - Jj Instrument) , Allies Forceps Small (Brand - Jj Instrument) , Mayo Scissior Str 5 ½ Sttilette Edge(Brand - Jj Instrument) , Mayo Scissiorcvd 6 ¼ Sttilette Edge(Brand - Jj Instrument) , Scissors Straight 6 Medium(Brand - Jj Instrument) , Scissors Straight 5 Small(Brand - Jj Instrument) , Scissors Straight 8 Big(Brand - Jj Instrument) , Steinman Pin Introducer Ss(Brand - Jj Instrument) , Towel Clip 6 Big(Brand - Jj Instrument) , Towel Clip 4 Small(Brand - Jj Instrument) , Wire Cutter 9 Standard Size(Brand - Jj Instrument) , Detnal Wire Standard(Brand - Jj Instrument) , Langenbeck Retractor Medium(Brand - Jj Instrument) , Langenbeck Retractor Small(Brand - Jj Instrument) , Langenbeck Retractor Big(Brand - Jj Instrument) , Cats Paw Retractor Standard Size(Brand - Jj Instrument) , K-Wire Cutter With Tungsten Carbide Tip 7 Standard(Brand - Jj Instrument) , Hintermann Distractor Medium(Brand - Jj Instrument) , Mippo Wire Passer For Long Bone Large(Brand - Jj Instrument) , Wire Bender Standard Size(Brand - Jj Instrument) , Kocher Clamp 8 Standard Size(Brand - Jj Instrument) , Glucometer (Brand-Dr Trust / Dr Morphen/Accucheck/Accurex) Fast Result In 5 Seconds Small 0.5Ul Blood Sample Size Large Memory. 10 Lancets Minimum Blood Sample: 0.5 Microlitre ; It Features A Large Display Screen That Can Store Up To 300 Test Results , Vortex Mixture (Brand -Remi /Borosil/ Benchmark) Type Of Product Cyclomixer Shaking Movement Orbital Orbital Diameter (Mm) 4 Motor Type Shaded-Pole Motor , Bio Saftey Cabinet Type-Ii A Microflow (Brand - Microflow / Thermofisher) Specification Material Of Construction (Main Body) Crca/Gi Powder Coated/Stainless Steel 304 Material Of Construction (Work Table) Stainless Steel 304 Dimensions External (Wxdxh) -1950 X 900 X 2250 Mm Internal (Wxdxh) - 1830 X 610 X 610 Mm Average Air Velocity - 90 ± 20% Fpm Hepa/Ulpa - Efficiency 99.997%/99.999% Class Level - Iso 3/5 (Class 100) Noise Level - 65 ± 5 Db Electrical - 230 V, 50 Hz, Single Phase Special Features - Motor Driven Front Door, Alarm, Hepa Filter Blockage, Timer For Uv Light, Power Socket Inside The Cabinet Pressure Sensor Monitoring, Digital Airflow Verification, Interior Eye Level Display, Display Parameters Including Down Flow Air Velocity, Total Operating Hours. Standards Us Fed Std 209 E, Iso 14644-1, Iest-Rp-Cc-002-2, Bsi Certifications- Ce & Iso , Co2 Incubator (Brand - Remi / Thermofisher) Specification Chamber Volume (150 Liters) Sensor Infrared Co2 Heating Method Air-Jacketed, Pid Control Co2 Range 0~20% V/V Co2 Control Resolution ± 0.1% (Ir Sensor) Temperature Range Rt+5~55°C Temperature Stability ± 0.1°C Humidity Method Natural Vaporization > 95% Co2 Recovery (Door Open 30S, Recovery To 5%) = 3 Min Temperature Recovery (Door Open 30S, Recovery To 37°C) = 8 Min Shelves 2 3 Interior Dimension (Mm) (W X D X H) 400 X 450 X 500 480 X 530 X 610 Exterior Dimension (Mm) (W X D X H) 590 X 687 X 790 670 X 767 X 880 Supply:220-240 Volts, 50 Hz Single Phase , Binocular Microscope - Olympus( Model Ch21i) / Magnus (Model- Pzb 22) (Specification) Optical System: - High Contrast Finite Colour Corrected Optical System Magnification:- 40X To 1000X Visual Magnification. Stand: Aluminium Die-Cast Stand With Hand Rests For Enhanced Comfort And Stability. Observation Head: - Sidentopf Binocular/Trinocular Head, 360° Rotatable, Interpupillary Distance 53-75Mm, With Dual Diopteric Adjustment. Eye-Piece: - Wide Field 10X F.O.V 22Mm, Anti-Fungal & Anti- Reflection Hard Coated (Optional 10X/18Mm). Nosepiece: - Reverse Angle Quadruple Nosepiece (Ball Bearing Type) With Precise Click Stops. Objective: - Qusp Series High-Contrast Flat Shield Plan Din Achromatic Objective 4X, 10X, 40X (S) And 100X Oil, (S), Anti-Fungal & Anti-Reflection Hard Coated. Mechanical Stage: - Rack-Less X Axis Double Plate Stage, Size 190 X 125Mm (+-5Mm) With Cross Travel 90 (X) X 50Mm (Y) On Ball Bearing With Co-Axial Controls. Hard Coated Surface For Scratch Resistance. Double Specimen Holder Clip. Focusing Control: - Co-Axial Coarse And Fine Focusing On Gear Systems For Smooth Operation. Fine Adjustment 0.2Mm/Rotation With Maximum 2-Micron Scale Increment. Condenser: - Sub-Stage Moveable Abbe Condenser, Centerable, Na 1.25 With Aspheric Lens. Iris Diaphragm And Special Frosted White Filter, Swing-In, And Swing-Out Filter Holder. Light Source: Led 3.5W 3V Illumination With Variable Illumination Control Universal Power Supply 110V-240V, Ce Approved. Supply With: Power Cable, Immersion Oil, Spare Bulb (In Led Only) User Manual, Vinyl Dust Cover, Cleaning Cloth, And 01 Units Fuses Optional Accessories: - Wooden Carrying Case, Pointers & Micrometre Reticules , Penta Head Microscope(Brand- Micron/Magnus/Weswox) Optical System- Infinite Optical System Viewing Head Inclination 30 Degree, Ipd: 48-75. 01 Piece Trinocular Head, Inclined At 30°, 360° Rotatable, Phototube With 100:0/50:50 Light Split With Sliding Prism. 04 Piece Compensation Free Binocular Head, Inclined At 30°, 360° Rotatable With Diopter Adjustment. Eyepiece-10 Pairs Of Wide Field Eyepiece Wf10x/22Mm Nosepiece- Inverse Quintuple Nosepiece. Objective Plan Achromatic Objective 4X Plan Achromatic Objective 10X Plan Achromatic Objective 20X Plan Achromatic Objective 40X Plan Achromatic Objective 100X Condenser - Swing Out Condenser N.A.0.9/1.25 Focusing-Coaxial Coarse And Fine Adjusting System With Tightness Adjustment And Upper Limited, Coarse Adjustment Range 30Mm. Fine Adjustment Precision: 0.002Mm Attachment- Multi Head Attachment And Support Stand. Stage- Ceramic Coated Double Layers Mechanical Stage Of 185X142 Mm With Capacity To Hold Two Slides At A Time With Slide Catcher On Left And Motion Control On Right Hand Side Illumination- External Illumination, Led 12V 100W Pointer - Multi Colored Ponters With Intensity Controllable Led Colored Indicator (Blue, Green And Red Led) Pointer 360 Rotatable, Brightness Adjustable, Arrow Control Sticks And Color Selection Dial. Video Adapter C Mount 0.5X Camera - 8Mp Hd Camera 4K Resolution With Removable Hd Card With Sd Card And Compatible Software. Display-43 Inch Hd Display Connected To Penta Head Camera For Live Display With Suitable Stabilizer For Display. Certifications - Ce(Notified), Ios 9001 (Iaf Accredited), Ios 13485 Warranty: 1 Year , All In One Pc ( Brand- Hp/Dell/Lenovo) All-In-One Pc 13Th Gen Intel Core I5 27 (68.6Cm) Fhd 16Gb Ram, 1Tb Ssd, Intel Uma Graphics, 710 White Wireless Keyboard And Mouse Combo (Windows 11 Home, Mso 21, Shell White, 6.72 Kg) 27-Cr0407in , Desktop ( Brand- Hp/Dell/Lenovo) 13Th Gen Intel Core I5 27 (68.6Cm) Fhd 16Gb Ram, 1Tb Ssd, Intel Uma Graphics, Wired Keyboard And Mouse Combo (Windows 11 Home, Mso 21) 27-Cr0407in , Air Conditioner( Brand- Hitachi/ Bluestar/ Daikin/ Carrier) Ac 1.5 Ton05star Smart Inverter Ac With Installation & Extra Wire /Pipe , Air Conditioner( Brand- Hitachi/ Bluestar/ Daikin/ Carrier) Ac 2 Ton05star Smart Inverter Ac With Installation & Extra Wire /Pipe , Lithium Battery 1500Wh Battery 48W 120Ah ( Brand- Luminous /Amaron) , Executive Premium Office Chair, Leather “Adjustable Arms Ergonomic Chair Must Behigh Back ( Brand- Godrej) , Office Table4x3 Feet( Brand- Godrej) , Mid Back Office Chiar ( Brand- Godrej) , Revolving Stool ( Brand - Aliza /Godrej) 3 Leg Ss Top Powder Coated Thicknessminimum- 14 Gauge , Steel Almirah W X H X D: 91.44 Mm X 197.866 Mm X 485.140 Feet For Office Use(Brand- Godrej) , Xerox Machine (Hp/Canon/Ricoh) Print Duplex, Copy, Scan, A3 Black And White Laserjet Printer, Enterprise Departments/ Distributed Workforce, Laser Printers Print Speed Is Up To 22 Pages Per Minute (Ppm) For Black And White Printing , Imcubator Electrical 23 Lts Thermostat , Centrifuge Machine Clinical ( Brand - Remi /Benchtop) , Salters Baby Wieghing Machine , Oto Scope , Chloroscope , Horrock,S Appratus Portable , Sound Level Meter Decible Meter With Lcd Display , Water Depth Sampler , Vaccine Carrier , Mosquito Catching Kit , Craft Water Testing Kit
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
11.
Educational and Research Institute #10317998 AOC
E-TENDER FOR PROCUREMENT OF EQUIPMENTs, INSTRUMENTs, MACHINERIES, TOOLS ETC. RELATED TO LABORATORIES AND WORKSHOPS OF PHYSICS, CHEMISTRY, CIVIL ENGINEERING, OF DARJEELING POLYTECHNIC, KURSEONG, DIST. DARJEELING, 734203- 1 LIST OF REQUIRED MATERIALS FOR CHEMISTRY LABORATORY 2 Buerette(Borosilicate Rotaflow 50ml) 3 Buerette stand andclamp 4 Bunsen Burner with Gas pipe 5 Wire Gauge and Stand 6 Tissue paper roll 7 Digital Conductivity meter(Desktop) 8 Redwood viscometer 9 Abels flash point apparatus 10 Pipette(Borosilicate 25ml) 11 Hand Glove 12 Spot test plate(6 cavity) 13 Filter paper - 110mm (1 roll sheet) 14 Wash bottle(Polyethylene 500 ml) 15 Muffle furnace 16 100 ml volumeteric Flask(Borosilicate) 17 Photo Colorimeter(Desktop) 18 Analytical Balance 19 Electric oven 20 Stop watch 21 Thermometer(0 -100 ˚C) 22 LIST OF REQUIRED MATERIALS FOR CIVIL ENGINEERING LABORATORY 23 AGGREGATE IMPACT VALUE(AS PER IS 2386) 24 AGGREGATE CRUSHING VALUE TEST(AS PER IS 2386, PART 4 40 T CAPACITY) 25 FLAKINESS INDEX &ELONGATION(AS PER IS2386 SPECIFICATION) 26 COMPLETE ABSOLUTE VISCOSITY TEST APP CONFIRMING TO IS 1206, PART II-1978(AS PER IS:1206, PART II) 27 PENETRATION TEST APP FOR BITUMEN(AS PER IS:1203 -1978, 220V, CAPACITY 50 & 100 Gm) 28 RING AND BALL APPARATUS(AS PER IS 1209 - 1978) 29 REBAR LOCATOR(DIM 120 X 60 X 25 mm) 30 CONCRETE CORE CUTTER(45L CAPACITY, DRILL DIA 132MM, VOL 93 X 35X 24 mm) 31 REBOUND HAMMER(IMPACT ENERGY 2.207 Nm, WEIGHT 5770 gm, RANGE 75mm) 32 BERNOULLIES THEOREM APPARATUS(MS SUMP TANK 80L, MEASURING TANK 10L, ISI MARK GI PIPES & CONTROL VALVE) 33 VENTURIMETER APPARATUS(SLUMP TANK 200 X 500 X 300 mm, 0.5 HP PUMP, COLLECTION TANK 500 X 500 X 600 M) 34 Piezometer with necessary apperantunces(Piezometer with Head Tank 300x300x450mm, measuring tank 300x300x300mm, Sump tank 600x600x300mm,0.5 HP Pump, Connecting pipes with necessary fittings and valves.) 35 U Tube differential Manometer with necessary apperantunces(U Tube differential Manometer Head Tank 300x300x450mm, measuring tank 300x300x300mm, Sump tank 600x600x300mm,0.5 HP Pump, Connecting pipes with necessary fittings and valves.) 36 Bourdon’s Gauge for measuring water pressure(Head Tank 300x300x450mm, measurement tank 300x300x 300mm, Sump tank 600x600x300mm,0.5 HP Pump, Connecting pipes with necessary fittings and valves.) 37 Pipe Friction Apparatus(Capacity 0.5HP, Sump Tank Capacity 1200 x 300 x 400 mm) 38 Pitot tube(Pitot Tube- Material Copper/SS of compatible size,Sump Tank 1200 x 300 x 400 mm) 39 TURBITY TEST APPARATUS(200 NTU, DIGITAL, LED DISPLAY, 230 V, 50 HZ) 40 APPARATUS FOR SUSPENDED SOLIDS DISSOLVED SOLIDS AND TOTAL SOLIDS IN WATER(HM DIGITAL, LCD DISPLAY, 357 A POWER) 41 HARDNESS TEST OF WATER APPARATUS(AE-201-40, 5-0.1-2 MG/L) 42 CHLORINE CONTENT DETERMINATION TEST APP(DPD METHOD, AE-201-0.1-2MG/L) 43 ARSENIC CONTENT DETEERMINATION TEST APP(5202 AS PER BP) 44 FLUORINE CONTENT DETERMINATION (AS PER BP) 45 PH METER(AS PER BP ) 46 JAR TEST APPARATUS(As per IS-3025(Part 50):2001 - Digital Jar test withJar capacity 1000ml, 30 to 150 RPM ) 47 PYCNOMETER BOTTLE(1L CAPACITY) 48 VANE SHEAR TEST APPARATUS(SPRING SET OF 2 KG-CM, 4.6 & 5 KG -CM) 49 VENIER TRANSIT THEODOLITE WITH TRIPOD STAND(MAGNIFICATION = 30 X FOCAL LENGTH =178MM) 50 QUICK SETTING DUMPY LEVEL WITH TRIPOD STAND(MAGNIFICATION = 24 X ANGLE OF VIEW = 2,BRAND =SOKIA) 51 PRISMATIC COMPASS WITH TRIPOD STAND(DIAMETER = 120 mm, DISPLAY = ANALOG) 52 PLANE TABLE WITH ACCESSORIES WITH STAND(TABLE SIZE= 23 X 32, MATERIAL = WOOD/ ALUMINUM/ BRASS, BRAND = SAPPHIRE) 53 GPS INSTRUMENT(GARMIN GPS 64sc SITE SURVEY, Handheld, SCREEN SIZE 2.5 inch ) 54 30m measuring METRIC TAPE ( Fibreglass)(Materials = rubber printing +ABS Plastic +PVC (Fibre glass) , Length = 30 m) 55 DIGITAL WEIGHING SCALE(Capacity of 20kg, with accuracy of 0.1gm) 56 DIGITAL WEIGHING SCALE(Capacity of 5 kg, with accuracy of 0.001gm) 57 LIST OF REQUIRED MATERIALS FOR PHYSICS LABORATORY 58 Boyle’s law apparatus complete set (With Mercury) 59 Stoke’s law apparatus for determining viscosity of liquid (Complete Set)(Complete Set with Glycerine) 60 Friction Apparatus(Complete Set with pulley and weights) 61 Flat plates of Brass / Glass(100x60x18mm) 62 Blocks of Wood with Hooks(12 cm X 8 cm X 8 cm) 63 Spring Balance(Range 5 to 1000 gm) 64 Set of 50 gms slotted weights(Slotted Weight - Iron Chrome Plated - 50gm × 10 = 500gm) 65 Flywheel Apparatus(Low Speed) 66 Meter Rod(Flat Meter Rod Scale) 67 Helical Spring(with Pointer and Hook) 68 Rigid Support (with Hanger) 69 Spherometer(5 mm to 200 mm) 70 Screw Gauge(0 - 25 mm, 0.01 mm)(Stainless Steel) 71 Vernier Callipers(0 - 12.5 cm metallic) (Brass) 72 Specific gravity bottle (with cap)(25ml) 73 Physical Balance + Weight Box(with weight box) 74 Convex Mirror(FL - 15cm, 20cm, 25cm) 75 Concave Mirror(FL - 15cm, 20cm, 25cm) 76 Wooden Bridge(for physicsl balance) 77 Wooden METRE Scale(1 m wodden scale) 78 Cantilever (Metal Bar)(1 m Metal rod with marking) 79 Metal Clamp(To fix cantilever to table) 80 Glass Slab(100x60x20 mm for refraction experiment) 81 Wodden Board(30x20 cm for refraction experiment) 82 Optical Bench(1.5 Meter with Both Rod Stainless Steel with Four heavy metal slider and with accessories.) 83 Convex Lens 50 mm diameter(25cm FL) 84 P O Box(Plug Type (Constantan & Manganin Coil)) 85 Resistance Box (1-500Ω) (1-500Ω range) 86 Resistance Box (1-1000Ω)(1-1000Ω range) 87 Resistance Box (1-10000Ω)(1-10000Ω range) 88 Rehostat(6 inches 100 ohms 1 ampere for resistance variance) 89 Resistance (2.5Ω, 5Ω, 10Ω, 15Ω)(5 of each value) 90 Battery Eliminator(2A, 12 V range) 91 P.N Junction Diode Characteristics Apparatus(Two Variable DC Regulated Power Supply (0 - 3V & 0 - 30V) with Two Analog Moving Coil Meters :( Dual range (3V/30V, 100µA/10mA). & 4mm Banana type sockets for connections. P-N Diode type: OA -79 2 Pcs) 92 Laying and Jointing PVC Pipe. Heading 93 8051 Trainer kit(8 BIT EMBEDDED MICROCONTROLLER TRAINER FEATURES • Single board design with various resources • Excellent training platform for embedded applications • Software development tools include assembler and ‘C’ compiler • Easy adaptability to different versions of microcontroller in the same family SPECIFICATIONS • Experimental board for 40 pin MCS51 and AVR family of microcontrollers • In-system programming (ISP) facility for many microcontrollers • Double RESET signal with manual key • Crystal frequency: 11.0592MHz • On-board RS232 compatible serial interface terminated in a 9 Pin D female connector • 4×4 matrix keyboard • 16×2 alphanumeric LCD connector (4-bit interface) and trimmer for contrast adjustment • Four 7-segment LED displays • I2C EEPROM (24Cxx) • Real time clock (DS1307) with lithium battery and SRAM • 8-high current output port (500mA) for driving external loads • Two 12V sugar cube relays • Continuous tone piezo buzzer • Temperature sensor socket with thermostat functions • Four 8-bit A/D converter, one 8-bit D/A converter provided by PCF8591 • All port-pins available on 10-pin box header • 8 LEDs for easy logic state monitoring • 8 input trigger switches using 8 push buttons • ISP programming with Flash ISP for AT89S51/52/8252/AVR • Infrared remote control receiver module IC supported • P89V51RD2BN • AT89S52 Installable software on CD • Programmers notepad : Free, open source, text editor • Flash ISP programmer software for 89SXX • Bascom basic compiler (demo version) • MIDE-51: An IDE for MCS-51 microcontroller • WinAVR : open source C compiler for AVR • Sample programs for peripherals DC 12V/500mA output power supply EXPERIMENTS • Study of LED blink • Study of dancing light • Study of LCD display • Study of LCD-keyboard display • Study of 7 –segment display • Study of RC5 remote control test program) 94 Suitable 8051 Trainer kit(With suitable Hardware and related software including AC variable voltage (0-10V) /current (0-5A) source, digital panel type ammeter & volmeter. Dedicated Intel 8051 based kit with ADC, 8255, 2K (extendable upto 8K) RAM & ROM, 8279,8253, necessary DC power supply and connecting cords.) 95 Suitable 8051 Trainer kit(Motor control interface card should have---- Motor Driver Unit, Interfacing Cards,Terminal connectors 20 - pin FRC Box Connectors, cables.8051 Micro Controller Kit DC Motor spec: Voltage 6.0V (Range: 1.5-12.), Speed: 2,700 rpm, Current: 0.02A, Torque: 5.88 mN. M;) 96 Suitable 8051 Trainer kit(Stepper Motor interface kit should have -- • 5V Stepper Motor • Angle control / Clockwise/ Counterclockwise • 1.8 degree Step Angle , • 34 mm Motor Length, • 1300 g.cm Holding Torque, • 6 no. Lead Wire • 0.3 A Rated Current, • 40 Ω Phase Resistance, • 20 mH Phase Inductance, • 0.18 Kg Motor Weight ; • Motor Driver Unit, Interfacing Cards, Terminal connectors 20 - pin FRC Box Connectors, cable, data sheet suitable for 8051 Micro Controller Kit) 97 Suitable 8051 Trainer kit(Microcontroler : Intel 80C51 Operating at 12 MHz Memory : -32 KB Onboard User Program Memory -12 KB Battrey Backed Up User program Memory -16 KB Battrey Backed Up User Data Memory Display : 40 Characters X 2 Lines LCD Display Keyboard : ASCII Keyboard Timer Counter Chip : 8253; 2 Counters available for User PPI : Two 8255 chips giving 48 TTL I/O Lines All Signals Terminated on 2 26 Pin FRC Connectors Serial Port : RS-232 Compatible serial port using 8250; signals treminated on a 9-pin D-type connector Expansion Bus : All address data & control bus brought out on 50 pinFRC connector for expansion Study Card Support : Dyna Series study cards support on this connector. All programs for study cards included in monitor program Modes Of Operation : -Introgation Mode : For interactive dialog with system -Assembler Mode : Line Assembler inbuilt in monitor helps you assemble programs directly -Single Step Mode : This mode is useful for Single Stepping inserting / removing breakpoints and debugging Software : – Powerfull Monitor Software with standard commands like move, fill, display/modify registers, execute Program, upload /download etc. – Single line assembler / dis-assembler.) 98 Suitable 8051 Trainer kit(With suitable Hardware and related software including AC variable voltage (0-10V) /current (0-5A) source, digital panel type ammeter & volmeter, frequency display,DW transformer of suitable rating for phase shifting (0-45 degree lead/lag). Dedicated Intel 8051 based kit with ADC, 2K (extendable upto 8K) RAM & ROM, 8279,8253, necessary DC power supply and connecting cords.) 99 8086 Trainer kit/ PC (Simulator) (8086 (INTEL),Operating Frequency : 6.144MHz crystal,32KB-SRAM for user Data,16KB-EEPROM (software monitor program),2x16 Char LCD display,Serial interfacing using 8251, 48 Programmable I/O Pins for ( 2 x 8255),Three 16-bit programmable timer (8253/8254),40-Pin FRC connector for Bus Extension,20-Pin FRC connector Add-on Interface from 8255,9-pin DB connector for UART (RS232) interface,Built-in assembler and dis-assembler,101-PC Type keyboard to enter user address/data commands.) 100 Zener Diode Characteristics/ Breakdown Voltage Kit(trainer kit) 101 JFET/MOSFET characteristics Kit(trainer kit) 102 UJT Relaxation Oscillator kit(trainer kit) 103 p.f. Meter, (Resolution - 0.001 p.f, 110/230 V AC) 104 inductance box, (10 micro Henry, 100 micro Henry, 1 mili Henry, 10 mili Henry, 100 mili Henry, 1 Henry) 105 capacitance box(1 nano Farad, 10 nano Farad, 100 nano Farad, 1 micro Farad, 10 micro farad.) 106 Rheostat(50 ohm, 10 Amp) 107 Rheostat(250 ohm, 2.5 Amp) 108 Rheostat(100 ohm , 5 Amp) 109 APFC panel(440 V, 180 A, 3ph Panel) 110 Kit to determine phase difference between voltage and current in series R-Land R-Ccircuits.(trainer kit) 111 Tachometer(5 digit LCD display to max 99999) 112 single Phase Transformer(1 KVA, 230/115V with all terminals boughtout for connections) 113 Isolation Transformer(220V / 220 V, 1 KVA) 114 Pulse Transformer(220 V , 100 W, 1ph Induction mpotor ) 115 3ph Transformer(3-phase, 1KVA, 415V/230V, transformer with provision for the external connection terminals to perform all vector groups (star-delta,delta-star etc.)) 116 3-ph Auto Transformer(415 V, 3ph, 20 hp.) 117 3ph Resistance Box(upto 415 V, 20 Amp) 118 1ph - Motor for Ceiling Fan(220 V , 100 W, 1ph Induction mpotor ) 119 Universal Motor (2000 RPM, 220 V) 120 Stepper MotoR Control Circuit with Stepper Motor(5 Amp, 220 V) 121 AC Servo Motor with control circuit(3000 RPM, 440V, 3PH) 122 DC Servo Motor with control circuit(3000 RPM, 440V, 3PH) 123 BuckChopper with Control panel(220 V, DC, 5 HP power rating) 124 BoostChopper with Control panel(220 V, DC, 5 HP power rating) 125 Ardino Uno R3 (Clock Speed 48 MHz, Flash Memory - 256 KB, SRAM - 32 KB, EEPROM - 8 KB) 126 Motor Driver L293D(4.5 V TO 36 V, 1 Amp) 127 pyranometer WITH SHADING RING FACILITY(Pyranometer with Shading ring facility:- Response time (95%) - < 1s, -Directional error (up to 80 ° with 1000 W/m2 beam) - < 10 W/m2, - Temperature dependence (-30 °c to +70 °c) - -0.15%/ °c, - Sensitivity – 60 to 100 µ v/W/m2, Impedance–50Ω, -Spectral range (50% points) – 400 to 1100 nm, -Typical signal output for atmospheric applications – 0 to 100 mV, -Maximum irradiance – 2000 W/m2, -Detector – Silicon photo-diode.One revolving platform for irradiance measurement at different tilt angle with Pyranometer fixing.Instruction manual and Commissioning of the instrument is included.) 128 radiation meter(Model no RN 2104) 129 solar cell characteristics apparatus(Complete set up of Poly crystalline silicon PV Cell with facility to measure the cell parameters – O.C. voltage (Voc), Short circuit current (Isc), Voltage-Current-Power at Maximum Power point (Vmp, Imp, Mpp), Fill factor, Efficiency and draw I-V characteristics of cell.Set up components – Poly crystalline Solar Module (12V, 5Wp), holding structure, Controller (12V, 5Wp), Halogen Lamp and holding structure with variable light intensity on cell and temperature measurement facility of cell, Battery, Necessary Voltmeter, Ammeter, Electrical Load, Wiring and cabling. Installation & commissioning of set up is included.) 130 Solar flat plate collector(One piece 100 LPD Flat plate collector with complete set up and measuring facility of temperature, flow, pressure, thermal efficiency. We have mentioned system specification; the specification of individual component should be given for evaluation purpose.) 131 Complete set up of 40 Watt, 12 V DC solar street lighting system for student demonstration. Necessary components with installation are required.(Supply of Polycrystalline solar PV Module - 75 Wp under STC;Rechargeable Battery - Minimum 12.8V, 30 AH capacity Lithium Ferro Phosphate battery with required MPPT Solar Charge Controller cum Inverter;Light Source - White light emitting diode (W-LED) 18 Watt, W-LED luminaire. Pole height 2.5 m adjustable above the ground level. The set up should be suitable for students’ demonstration.) 132 inverter, (12 V DC) 133 charge controller(12.5 V , 20 A) 134 ELCB, (Upto 30 mA) 135 MCCB, (415 V AC, 16 Amp) 136 RCCB(Upto 30 mA) 137 i) ACSR(.3m) 138 ii)Cu(.3m) 139 iii)Al(.3m) 140 iv)Galvanized Steel(.3m) 141 v)Cadmium Copper(.3m) 142 vi)AAC(.3m) 143 vii)AAAC(.3m) 144 viii)ACAR(.3m) 145 i)Belted Cables(.3m) 146 a)Screened Cables - H-Type Cables(11kv,0.3m) 147 b) Screened Cables - S.L Type Cables(66kv,0.3m) 148 c)Screened Cables - H.S.L Type cables(66kv,0.3m) 149 a)Pressure Cables - Oilfilled Cables(66kv,0.3m) 150 b)Pressure Cables - Gas filled Cables(66kv,0.3m) 151 iv)XLPE Cables(0.3m) 152 v)PVC Cables(0.3) 153 vi)FRLS Cables(0.3) 154 a)Pintype - 11KV(procelain)/(polymer)(11kv) 155 b)Pintype - 33KV(procelain)/(polymer)(33kv) 156 ii)Disc Type with metal links(procelain)(11kv) 157 a)Disc Type11KV(polymer)(11kv) 158 a)Disc Type 33KV(polymer)(11kv) 159 iii)Shackle type(procelain)(230v) 160 D.C Network Analyzer (2-wired) 161 Distributor simulator using Power Transmission Trainer(trainer kit) 162 Digital Megger 250V,500V,1000V( 250V,500V,1000V) 163 PVC conduit1/2 inch,10ft(0.5 inch 10ft) 164 Schering bridge(trainer kit) 165 Anderson Bridge(trainer kit) 166 Kelvins Double Bridge(trainer kit) 167 Wheatstone Bridge(trainer kit) 168 i) SWITCHES - Float switch 250v sensor for water level(250v,6A) 169 ii)SWITCHES - Proximity switch(250v,6A) 170 iii)SWITCHES - Limit switch(250v,6A) 171 iv)SWITCHES - Push button switch(230v,6A) 172 v)SWITCHES - Pressure switch(Danfoss KP35)(23v,6A) 173 vi)SWITCHES - Thermostat (30 Amp)(230v,30A) 174 vii)SWITCHES - Electromagnetic relay (15Amp,250V)(250V,15A) 175 viii)SWITCHES - selector switch(230v,6A) 176 Infra red camera for therma imaging 32*32*pixel infrared sensor(Hand held thermal imager: Object Temperature Range: -20° to 550°C (-4° to 1022°F)Temperature Accuracy:  ±2°C (3.6°F) or 2% of reading (Environment temperature 10-35°C; Object temperature >0 C)Field of View (FoV)/Minimum Focus Distance: 56°x 42°/ 0.5mSpatial Resolution (IFoV): 3.75mRadImage Frequency: 25Hz Focus FreeZoom: 1-32x continuous, digital zoom Focal Length: 3.2mm Focal Plane Array (FPA)/Spectral Range: Uncooled microbolometer/8-14μm IR Resolution: 256×192 pixels Display: 3.5 in. LCD, 640×480 pixels TouchscreenImage Modes: Infrared Image, Visual Image, Picture in Picture, Auto-fusion, ZoomColour Palette: IRON, Rainbow, Grey, Grey Inverted, Brown, Blue-Red, Hot-Cold, Feather, Above Alarm, Below Alarm, Zone Alarm, Vision ZoneAutomatic Hot/Cold DetectionCenter Spot, Three manual spotsStorage Media: 8 GB MicroSD card and 3.4GB internal EMMCData transfer between camera and PC. Live video on camera and PC.Video Storage Standard MPEG-4 encode. 640×480 at 30fps, on memory cardSimultaneous storage of IR and visual imagesImage Storage Format Standard JPEG or HIR files including measurement data, on memory card >6000 picturesImage Storage Mode IR/visual imagesImage Analysis ToolsInterfaces: USB Type C and WiFiRechargeable Li-Ion battery, 4 hours operating timeAuto Power-off) 177 Projector(sony ) 178 Printer with Xerox cum Scanner(Epson) 179 Projector- screen(150 inch)
Contract Date: Jan 24, 2025 Contract Value : 13.89 Lakh
Government Departments No of Bidders 16
West Bengal View Result →
13.
Educational and Research Institute #9832816 AOC
PROCUREMENT OF MACHINERIES, INSTRUMENTS, TOOLS AND EQUIPMENTS ETC. RELATED TO ELECTRICAL ENGINEERING AND ELECTRONICS AND TELECOMMUNICTION ENGINEERING LABORATORIES AND WORKSHOPS OF MATHABHANGA GOVERNMENT POLYTECHNIC, MATHABHANGA, COOCH BEHAR, WEST BENGAL- 1 ANALOG ELECTRONICS LAB-I (3RD SEM) 2 50 MHz Dual Channel CRO• Automatic Measurements of Signal Parameters like .Pk-Pk, Average, Max. , Min., rms, top etc. Voltages and Frequency, Period,Width,Duty Cycle, Rise Time, Fall Rime • Waveform and Set up storage facility.• Colour Display. • Advanced features like sequential acquisition of up to 1000 trigger events should be possible.• Standard USB Host & Device Connectivity. • Standard 23 Automatic Measurement andMath Function Including FFT.• Education student Lab guide and professor slide set.DETAILED TECHNICAL SPECIFICATIONS:-a)No. Of Channels:2b)Bandwidth :50 MHzc)Maximum Input:400 V (peak ac + dc) d) Sample Rate :1 GSa/sece)Waveform Update Rate : 400 Waveforms/secf)Memory : 16 Kpts/Ch.g)Time Base : 5nsec / div. To 50 sec./div.h) Resolution : 8 bitsi) Display: 5.7 inch Colour QVGA TFT LCD Display.j)Trigger Modes: Force, Edge, and Video, Pulse width.k) Built In Interface : Standard USB 2.0 (Host and Device)l)Power Supply: 230 V AC Supply, 50 Hz. 3 Function Generatori)Itshould be a waveform / function generator which can be upgraded to an arbitrary waveform generator . It may also have the feature upgrade the frequency of operationii) Should have low harmonic distortion and jitter.DETAILED TECHNICAL SPECIFICATION:--• Frequenc : 1Hz. to 20 MHz for Sine , Square and PulseWaveforms and 1 Hz. to 20 MHz. for Noise• No. of Channels: 1• Frequency Resolution : 1Hz.• Amplitude : 1 mVpk-pk to 10 v (pk - pk) in 50 ohms. • Duty Cycle for Pulse : 0.01 % to 99.99 %• Standard Waveforms: Sine,Square,Ramp,Pulse,Triangle,•Operating Modes: Continuous,Modulate,. .• Modulation Types: AM,FM,PM,FSK,BPSK,PWM• AM : Source both Internal & External, Depth 0 to 120 %With 0.01 % resolution.• FM : Source both Internal & External, Deviation 1Hz to 15 MHz• PM: Source both Internal & External, Deviation 0 to 360 deg C.• PWM : Source both Internal & External. Deviation 0 % to 100 %.• Power Supply : 230 v,50 Hz. ac. 4 Digital MultimeterDC Voltage:400mV to 1000V , AC Voltage: 400mV to 1000V,DC Current: 4mA to 10A, AC Current: 4mA to 10A, Resistance: 100 ohm to 40Mohm, Resistance: 100 ohm to 40Mohm,Capacitance: 4nF to 200µF, Duty Cycle: 0.1% to 99.9%, Frequency: 10Hz to 10MHz, Temperature: 20oC to 750oC,Transistor Test: Yes (for NPN & PNP), Diode Test: Yes, Continuing Buzzer: Yes, Power Supply: 9V, Manual and Auto ranging,Display: 4½ Digit 5 To study the V-I characteristics of UJT Trainer kitVariable DC Power Supply 1.2V to 12V/500m,A DC Power Supply for DPM 5V/500m,A UJT (2N2646) UJT Characteristics UJT Relaxation Oscillator with two different Timing Capacitors ,DigitalMeters for Measuring Voltage and Current ,Set of Patch Chords & User Manual 6 To study the input and output characteristics and to find the h-parameters of a BJT for : —(a) C-E configuration,(b) C-C configuration,(c) C-B configurationHARDWARE SPECIFICATIONS :Dual Variable DC Power Supplies 0V to 12V/500mA and0V to 15V/500mA DC Power Supply for DPM 5V/500mAIndependent Base Limiting Resistors - 2 Nos.(low value) Independent Collector Resistor - 1 No. Transistor( NPN Type SL100) .All Inputs/Outputs through 2mm Sockets set with provision of Digital Multimeter for measuring input and output. 7 ANALOG ELECTRONICS LAB-II (4TH SEM) 8 Feedback Amplifier Trainer12 V DC supply with +/- 10%accuracy,configurable circuit,Inbuilt sine wave generator with frequency range 10 Hz to 10 KHz rangeand Amplitude variation 10mV to 4V, NPN transistor. Voltage Series & Shunt and Current Series & Shunt configurable operation. 9 Oscillator Trainer KITi) Hartley, Colpitt ,Wien Bridge Oscillator Trainer kit : i) NPN Transistor ii)On boardoscillator section,separate tank circuit (iii)Biasing Voltage :+12 V , -12 V ,+12V SMPS Adaptor provided with the trainer for power supply.Designed by considering all the safety standards. Provided with an extensive manual.Power Supply to Kit: 230VAC,50Hz, All interconnections are made using 2mm banana Patch cords 10 To determine the following characteristics of op-amp: —a) input offset voltage, b) slew rate, c) non-inverting gain, d) inverting gain e) adder, f) subtractor, g) differentiator, h) integratorandi) voltage followerTo adjust offset null, setup the closed loop amplifier using IC741 op-amp also to (a) dc gain (b) ac gain. The set complete with +/-12V DC regulated power supply with milli voltage source, Null arrangement and 2V/20V dual range digital voltmeter , In built sine wave,triangular wave & square wave Generator of1 KHz, 15V Vpp (approx.), DC Power Supply : 0 - 5 V (vary through (2No.) rotary switch for specific voltage level 11 DIGITAL ELECTRONICS LAB (3RD SEM) 12 Complete setup to implement encoder, decoder ,multiplexer andde-multiplexer5V D.C. at 100mA, IC regulated power supply,21 Input Switches for data input,IC For Multiplexing 74150 is provided on board with Combinational Circuit, IC For Demultiplexing 74154 is provided on board with Combinational Circuit, One Not Gate is provided on board using 7404 ,16 Output LEDs with driver circuit to observe the output of Multiplexer Demultiplexer, A Pulser to provide the pulses manually for triggering,230 V ±10% at 50 Hz A.C. Mains,necessary patch cords and user mannuals. 13 Complete setup to design / construct parity generator, checker andcomparatorDC Regulated Power Supply 5 VDC/150 ma,5 SPDT switches provided for selecting logic ‘1’ & logic ‘0’,2 output indicators,Sufficient no of 4mm Patch Cords for Interconnection,Power Cords 230v, 50Hz,necessary patch cords and user mannuals. 14 Complete setup to design / construct binary synchronous and asynchronous counterTrainer kit for binary Synchronous and Asynchronous counter. with power supply, display unit, patch cords, manuals and necessary IC. 15 Digital I.C TesterUniversal IC tester: 40 pin DIP ZIF socket, 50 cherry keys Key pad and 16 X 2 LCD Display, suitable for testing of Analog IC, Digital IC and 7-segment display. 16 A/D & D/A Converter TrainerFEATURESAnalog To Digital Converter• 8-bit descrete ADC•12-bit monolithic ADC IC•On-board signal generator with adjustable amplitude levels•On-board LED bank to observe digital outputs•Power supply : +5V, ±12V GND•Interconnection is provided by 2mm connectors•Experimental manualDigital To Analog Converter•8-bit binary weighted resistors DAC•8-bit ladder type D to A converter•8-bit D to A converter using monolithic IC•Simple construction using Op-Amp and resistors•Onboard switches are provided for digital pattern generation•8-bit digital inputs ranges from 00 to FF•Variable frequency counter to study the settling timeSPECIFICATIONS•8-bit binary weighted and 4-bit ladder type DAC are constructed using discrete components•8-bit monolithic DAC having settling time in the range of ns, wide power supply range, low power consumption, full scale error ± 1LSB•8-bit digital ramp ADC constructed using discrete components•12-bit monolithic ADC having conversion time in the range of μs, industry standard pin out, wide input range•8 onboard switches to provide digital inputs to DAC•8-bit counter running on external clock frequency to study settling time of DAC• Built inlow frequency clock generator•1 KHz sine wave with adjustable amplitude level•Onboard variable DC voltage source for studying unipolar and bipolar modes of ADC •12 output LEDs to observe ADC outputs•ADA operates on DC power supply (+12V,-12V,+5V and GND)•Interconnection is provided by standard 2mm connector•Extensive experimental manual is provided with the kit EXPERIMENTSAnalog To Digital Converter• To study and measure resolution of ADC•To measure the conversion time of the ADC•To study full scale adjustment for unipolar and bipolar signals•To study the working of ADC 17 NETWORK ANALYSIS LAB ( 3RD SEM) 18 To study the series and parallelresonant circuitIndependent Resistors - 3 Nos. ,Independent Capacitors - 3 Nos.,Tapped Inductance. All Inputs/Outputs through 2mm Sockets Set of Patch Chords & User ManualWITH SIGNAL GENERATOR, COUNTER, DIGITAL METERS FOR INPUT & OUTPUT and user manual 19 To test and to measure the cut –off frequencies of the following: —(a) constant k-type low pass filter;(b) constant k-type high pass filterTwo Independent Passive LC Filter Networks (LPF & HPF) All Inputs/Outputs through 2mm SocketsSet of Patch Chords & User Manual 20 To study standing wave pattern for a transmission line of finite length with:(a) open termination,(b) shorted termination andmatched termination. 2.To measure the attenuation constant and phase shift constant for matched terminationTransmission Line Trainer Features:* 30-300 Mhz sweep source with detector* Calibrated attenuator* Displays standing waves/maxima-minima on CRO* Uses actual coaxial lines rather than simulated ones.* Impedance matching.* Measures VSWR, reflection coefficient, characteristic impedance, velocity of propagation, dielectric constant and signal attenuation in TDR.* Measure parameters of 50, 75 and 300 Ohms cables* Study Time Domain Reflectometry.* Study location and nature of discontinuities,Open/short, mismatched terminations, etc.* Offers a complete view of the transmission line in analog and digital domains, which is essential for complete understanding of transmission line behavior.Technical Specifications:A. Frequency Domain AnalyzerFrequency range : 30-300 MHz typical LCD Display. Level : 100mV p-p Attenuator 50 Ohms : 0.5, 1, 2,4, 8,15 dB,Output Impedance : 50 Ohms Scope out : X-Y output to scopeB. Resistive Impedance Analyzer ,Characteristic Imp. : upto 800 ohms ,Display : LCD C. Time Domain ReflectometerPRR Short range : 10MHz typical,Pulse width : <10ns typical, PRR Long range : 100KHz typicalAmplitude : 1V nominal, Output Impedance : 50 OhmsAccessories:Lengths of 50 ohms and 75 ohms coaxial cable, 300ohms, parallel line, lossy line, Tee connectors, ,Standard load of 50and 75 ohms, Various capacitive and inductive loads, shorts, Balun 1:1 & 1:4, Operating manual, Mains cord 21 COMPUTER PROGRAMMING LANGUAGE LABORATORY (3RD SEM) 22 Computer Programming Language LaboratoryTURBO C++ Software 23 MICROPROCESSOR LAB (4TH SEM) 24 8085Microprocessor Trainer KitHigh performance 8085A CPU operating at 3 MHz.16 K powerful monitor FIRMWARE expandable to 32 K. 64 K user RAM. Expanded RAM accessible using bankWrite protect facility for RAM. 3.6 V Ni-Cad battery back up. Versatile Keyboard/Display controller using 8279. 24 highly reliable dual function keys. 6 digit seven segment LED display.Parallel I/O lines available through two 8255 chips. Serial I/O through 8251 USART, with on-board level shifters 1488,1489.Programmable communication parameters. Built-in audio cassette interface.3 channels of 16 bit timer/counters from 8253.Powerful 8085 interrupt capabilities. On-board EPROM programmer with ZIF socket for programming 2716 to7512 EPROMs and various EEPROMs. Normal and intelligent programming modes.On-board ADC,DAC, opto-isolator, reed relay and miniature speaker. On-board logic probe.Single stepping, break pointing and machine cycle single stepping facility. Monitor functions can be called through software interrupts. Large collection of application software provided. All address, data and control lines from the CPU, buffered and brought out on 50 pin connector. Additional Stepper motor of specification:Shaft type: 5 mm DCurrent rating: 1200 mA2Voltage rating: 4 VHolding torque: 44 oz·inSteps per revolution: 200Resistance: 3.3 Ohm2Inductance per phase: 2.8 mHNumber of leads: 6Lead length: 30 cm 25 Microprocessor 8086 Trainer KitINTEL 8086CPU AT 4.77 MHZ CLOCK SPEED,16KB for monitor EPROM upgradable to 64kb16KB RAM expandable to 64KBBattery backup provision for RAM upto 64KB16 x 2 (or) 20 x 4 Alphanumeric LCD display101 keys IBM compatible keyboard24 TTL I/O lines brought out to two nos., of 26 pin FRC connector1 number of standard RS232C compatible serial port brought out to a pin D type male connector.3 channel 16 bit counter/timer using 8253.Fully buffered address data and control signals terminated at a 50 pin header(VXT BUS) for interfacing VBMB seriesof experiment boards and bus expansion.8 no’s of interrupt lines are terminated at a 10 pin connector.Kit operates with a single +5V/DC supplyThe kit and the power supply are mounted on a attractive light gray color fiber glass cabinet with fiber glass top cover.Built-in line assembler & DisassemblerPowerful debugging monitor to develop user program. 26 ELEMENTARY COMMUNICATION ENGG. LAB 27 To study the amplitude modulation and demodulation Ttrainer kit Features of Amplitude Modulation and Demodulation Trainer:On-board message signal with variable Amp/Freq On Board carrier signal with variable Amp/Freq AM Modulation using MC 1496 IC Demodulation using Diode Detector and LPF,6th Order LPF,Op Amp Based Variable AmplifierInternal Power Supply +5V , +12V/ 500 mATechnical Specification :Message Signal:Sine wave Frequency 100 Hz to 2.8 KHz, Amplitude 0 to 3VCarrier Signal: Sine wave Frequency-28 KHz to 108 KHzAmplitude 2V,Modulation : Balanced ModulatorAmplifier : Op Amp BasedDemodulation : Diode Detector & LPFLow Pass Filter : 6th Order LPFSupply Voltage (Board) : +12V, +5V / DCSupply current : 100 mA (Minimum)Input Voltage : 230 V/ 50 Hz ACInterface connectors : 2mm socket 28 AM/FM Radio Receiver kitFrequency range: 400KHz ~ 1.5MHzIntermediate frequency: 455KHzInputs: RF signalOutput IF frequency: 455KHz adjustableIF filter: Dual tune LC, RF amplifier with variable gain ,Mixer (frequency converter),Local oscillator:Output Signal: Sine waveFrequency range: 400KHz ~ 1.5MHz ,Amplitude: Adjustable from 0Vpp ~ 2VppOutput impedance: 50 Ohm ,1st and 2nd IF amplifierCentral frequency: 455KHz, Load impedance: Variable R-L-CGain: 40db with automatic gain control, Diode envelope detectorDetection of the envelop with variable RC filter. Audio output:Amplifier with audio jack, Audio amplifier gain: 26Db, Receiving media :MW coil antennaFM radio receiver, Reception range: 88MHz ~ 108MHz with continuous tuningTuning circuit: Using GANG capacitorIntermediate frequency: 10.7 MHz with ceramic filterEXPERIMENTS:Study of double sideband AM reception using envelope diode detector,Study of single sideband AM reception using product detector,Study of image frequencies,Study of adjustment of receiver tuned circuits,Voice reception using DSB/ SSB AM receiver (super heterodyne receiver)Effects of switch faults FM detection output level: 77.5Vrms (typical)FM detection output distortion factor: 0.3% (typical)Audio amplifier: Gain up to 46DbReceiving media: Adjustable telescopic antennaPower supply: -12V,+12V,+5V,GNDOutput volume regulation, output load impedance of 8 OhmEXPERIMENTS AM radio receiverTo study AM radio receiverTo study of image frequencies for AMFM radio receiverTo study FM radio receiverTo measure the frequency response of Audio amplifier 29 Pulse code Modulation and Demodulation system trainerInbuilt variable DC and 1 kHz AC Modulating Signals, Facility for applying external AC or DC Modulating Signal, Modulating circuit consists of a Positive Clamper, Sample and Hold (S and H), Analog to Digital Converter (ADC), Parallel to Serial Converter and Control Signal Generator, Observation of binary coded analog information by the LED status for both Modulation and Demodulation, PCM Modulation technique using IC, Built-in Pulse Code Demodulation circuit using a Serial to Parallel Converter and Parallel Shift Register DAC, Low Pass Filter for both AC & DC, Observation of Modulated & Demodulated waveform, Provision to monitor output on CRO, Clock to be provided from the Pulse Code Modulator to Demodulator circuit, Built-in IC based DC Regulated Power Supply with indication for power ON & fuse, 4 mm Patch Cords – 4 nos, Supply required 230V, 50 Hz and 1 phase AC, Comprehensive instruction manual complete with theory and operating details. 30 Frequency Modulation andDemodulation kitFM Modulators :Audio Oscillator : Sine wave (10Vpp adjustable) Frequency (300 Hz - 3.4 KHz) FM Modulators : 3 nos. • Reactance Modulator : Carrier Frequency - 455 KHz (± 3KHz) Varactor Modulator : Carrier Frequency - 455 KHz (± 2KHz) VCO Based Modulator : Carrier Frequency - 10 KHz - 200KHz (adjustable) ,Mixer / Amplifier adjustment FM Demodulator:Detuned Resonant DetectorQuadrature DetectorFoster-Seeley DetectorRatio DetectorPhase-Locked Loop Detector (IC HEF4046 based)Phase-Locked Loop Detector (IC LM565 based), Low Pass Filter : 3.4 KHz Cut off Frequency Amplifier (with adjustable gain) 31 DPCM & ADPCM MODULATION / DEMODULATION KITDPCM & ADPCM MODULATION / DEMODULATION KITOn Board Signals:. Frequency: 500KHz, Amplitude: 0 to 4 v pp 32 CONSUMER ELECTRONICS LAB (4TH SEM) 33 Black & White TV Trainer kit with provision of fault findingSystem: CCIR-B, 625 lines, Power supply :230V Ac, 50 Hz, Regulation range170v Ac to 270v Ac.,Power consumption :70 watts,Gain Limited sensitivity:55 dB for Video & 25 dB for AudioSound output :2.0 watts maximum. Screen size :20 Diagonal. Channel :VHF 2 to 12, UHF 21 to 68,S-band and Hyper-band. Isolated shockproof chassis. Sections:Electronic tuner, VideoI.F Section, Sound I.F, Video amplifier, Horizontal oscillator, Horizontal driver and EHT, Verticaloscillator, and output, S.M.P.S power ,Controls: Volume, tone, Brightness, contrast. Distortion :10 to 15% in Live program due to expanded P.C.B. All parts are soldered on Tags on SINGLE PCB of size 19x15” with complete circuit diagramSCREEN PRINTED in different colors with FAULT CREATING FACILITIES to create more than 25 faults. Standard Accessories : 1. Frame with PCB mounting.2. Picture tube fitted in wooden cabinet 3. A Manual having 20 practical. 34 DTH TV and SET TOP BOX TRAINER KITPower supply 230 V ,50 Hz, Input frequency: KU Band, Output frequency: 950-1450 Mhz.Noise temp: 35 degree,DISH ANTENA ,LNBIF FREQUENCY: 70 MHz 35 Colour TV Trainer with provision of fault findingStandard : CCIR-B-PAL-G, 625 Lines Channels : 230, 2 - 4 VHP I (VL), 5 - 12 VHP III (VH), 12 - 100 : BAND IV & V, else : S BAND & HYPER BAND Picture Tube Size : 36 cms. Diagonal RF Input Impedance : 75 W (Ohm) 36 DIGITAL & MICROWAVE COMMUNICATION ENGG. LAB 37 Spectrum AnalyzerFrequency range:9 KHz to 26.5 GHz,Phase noise :-102dBc/Hz, Max third order dynamic range, 1 GHz: 111dB, Displayed average niose level,1GHz:-163dBm,Standard attenuator range/step:50dB/10dB,70dB/10 squaredb,Overall amplitude accuracy:+/- 0.50dB 38 Antenna Trainer 86 - 860 MHZSPECIFICATIONS:Radiation pattern plotting software• Stepper motor controlled receiver stand.Antenna Measurement System:RF Source•Source types :PLL Synthesized with integrated VCO• Frequency range :100MHz to 3GHz• Dynamic range :85dBm• Transmitted power min:-50dBm• Transmitted power max:+5dBm • Impedance :50W / SMA RF Detector• Detector type: logarithmicdetector• Frequency range : 1MHz to 8GHz• Resolution: 0.1dB• Dynamic range : 85dB (±3dB)• Noise level : -90dbm• Impedance: 50W /SMA• Representation of RF level : dBmDisplay•128x64 Graphic LCD Display with backlit. Keypad•15 Key Membrane Keypad for user entry.Stepper motor controller•1.80 Resolutions.List of Standard 22 Antenna Suppliedwith the setupWire Antenna1.Monopole Plane base ground2.Dipole (2nos.) 3.Yagi4.Folded Dipole 5.Vee Dipole6.Rectangular Loop 7.HelicalMicrostrip Antenna 1.Planar Dipole 2.Planar Monopole3.CMSA 4.TMSA5.2X1 ARRAY 6.Annular ring7.Chip Antenna8.RMSA9.RMSA- Circular PolarizedAperture Antenna 1.E- Horn2.Open ended Waveguide Rectangular Array Antenna 1.Broadside Array2.Collinear ArrayReflector Antenna 1. Corner reflectorSOFTWARE• Radiation pattern plotting and analysis software suitable for windows environment Antenna PositionerThe Transmitter and Receiver Antenna stand is made of special material which is inhert to EM frequency and it has engraved height and angle scale on It. It has facility to adjust the height and level. Universal plug and fix Antenna mounts are provided to hold the antenna assembly in vertical and horizontalorientation for co and cross polarization.ACCESSORIES • SMA (M) to SMA (M) 50W flexible cable : 02nos• USB cable ( Male A to Male B): 01no• 3 Pin 6 Amp Power chord: 01no • Manual : 01no • Software on CD: 01no EXPERIMENTS• Measure the variation of field strength /inverse square law• Prove the reciprocity theorem of antenna• Plot Radiation pattern of WIRED Antenna Omni directional antenna• Plot Radiation pattern of all Aperture Antenna• Plot Radiation pattern of all Reflector Antenna• Plot Radiation pattern of all Array Antenna• Measure co-polarization, cross polarization 39 Microwave Test Bench (KLYSTRONBased)Klystron Power Supply: Specifications:Input Voltage -230V+/- 10%, 50Hz AC, Beam supply- Voltage:200-450V continuously variable; Current:Regulation: better than 0.5% for +/-10% variation in mains supply voltage; Ripple: less than 5mV rms ,Repeller Supply -Voltage:-10V to -270V continuously variable with respect to klystron cathodeRegulation: better than 0.25% for +/-10% variation in mains supply volt , Heater Supply - 6.3V DC (regulated)Modulation- Square Wave : Frequency 500Hz to 2000Hz; Max. Amplitude- +110V peak to peak, Amplitude and frequency continuously variable; Sawtooth- Frequency 50Hz to 150Hz; Max. Amplitude- 60V peak to peak, Amplitude and frequency continuously variable.VSWR Meter: (Sensitivity: 0.2 micro Volts at a 200 ohm input impedance for full scale deflection, Noise level: At least 5 dB below full scale at rated sensitivity and maximum, bandwidth with input terminated in 100 ohms and 500 ohms for low and high respectively, A/C output : BNC Connector for amplified output, Frequency : 1000Hz +/- 10%,Power : 230 Volts AC, 50Hz, mains supply) 40 ASK / PSK / FSK Modulation And Demodulation KitFEATURES•VLSI based design •Separate component and operational area •Acrylic cover for component safety •Modular organization of circuit functions •Test points to access signals at every stage of circuit operation •Multimedia based interactive e-manual Data Simulator: Onboard 8-bit variable NRZ-L pattern,Crystal Oscillator: 32.768 MHz,Data Clock: 256 KHz,Data Format: NRZ (L),Onboard Carrier Sine Waves : 1MHz (0°), 1MHz (180°), 500 KHz (0°),Power Supply: +12V, -12V, +5V, GND. 41 Microwave Test Bench (GUNN Based)Gunn microwave test bench:Gunn Power Supply (0 - 12 Volts variable,1 Amp. Max,Modulation Frequency: 1KHz +/- 10% (900-1100 Hz),Output Connector: BNC(F) for Gunn Oscillator & TNC(F) for Pin Modulator,Modulation: Square Wave, Frequency : 500Hz to 2000Hz)• Gunn Oscillator • Isolator• PIN modulator• Variable attenuator • Detector Mount• SWR meter(Sensitivity: 0.2 micro Volts at a 200 ohm input impedance for full scale deflection, Noise level: At least 5 dB below full scale at rated sensitivity and maximum, bandwidth with input terminated in 100 ohms and 500 ohms for low and high respectively, A/C output : BNC Connector for amplified output, Frequency : 1000Hz +/- 10%,Powe : 230 Volts AC, 50Hz, mains supply) 42 1 GHz spectrum Analyser1 GHz spectrum Analyser with tracking generatorFrequency range: 150 KHz to 1000 MHzFreqency Resolution: 1 KHz CF entry 40 Hz sweep resolution at 2 KHz per Division,Frequency Display: 61/2 digitFrqency Control: Digital Phase LockResolution Bandwidth: 3 KHz, 30 KHz, 220 KHz, 4 MHz. 43 INDUSTRIAL ELECTRONICS LAB -I (5TH SEM) 44 Trainer Kit to study Reverse Recovery Characteristics of Power DiodesThe single Board trainer Kit should contain IC Regulated Power Supply, Different types power diodes, Digital Ammeter and Voltmeter and other necessary passive components 45 To study drive circuit of SCRIsolated 230 V/40 W AC Power Supply1.2 V to + 15 V/500 mA DC Power Supply* 0-18 V/500 mA,50 Hz, AC Power Supply* Variable frequency triggering pulses* DC Gate signal control, Pulse gate signal * Synchronous AC gate control signal through DIAC* UJT Triggering* 10:1 On- board resistive attenuator * Provision for 40 W Lamp Load* Set of Patch Chords & userManual. 46 To study a single phase rectifier—output waveform with phase control circuitTrainer Kit to study Single Phase Full wave Bridge Rectifier for fixedDC output, Half Controlled and fully controlled rectification facilities with R and RL, loads 1000 Ohms 10 Watts, 14 ma @ 0.05 A inductive loads.The Single Board Trainer Kit contains :(i) Source for rectification of 4 to 24 V DC fixed and variable output @ a max of 500 ma helps to construct and study Series and Parallel resonance Circuit.(ii) Four Diodes and 4 SCRs in bridge configuration with gradual firing controls and necessary capacitive, inductive and Pie filter components.(iii) Digital Ammeter and Voltmeter. 47 To study a polyphase rectifierIsolated 230 V/40 W AC Power Supply Isolated stepped down 3 PH supply. * 3 Phase diode rectifier in open condition*Provision for Load& CRO output.* Electronic phase sequence finder.*Set of Patch Chords & user Manual 48 INDUSTRIAL ELECTRONICS LAB-II (6TH SEM) 49 Servo Regulator Stabilizer Study Kit500VA Servo stabilizer , 2 Amp Variac, Digital input & output meters, Lamp load, Set of Patch Chords & userManual. 50 To study a Jones chopperIsolated 230 V/40 W DC Power Supply, + 5 V/500 mA DC Power Supply* SCR Jones chopper* Gate firing pulses for Jones Chopper* 10:1 On-board Resistive Attenuator* Provision for 40 W Lamp Load* Set of Patch Chords & userManual. 51 To study speed control of induction motor by voltage and frequency variationV/F CONTROLLER 1 HP, AC SQ. CAGE IND. MOTOR 1 HP,DIGITAL VOLT & AMMETER. 1 PHASE I/P & 3 PHASE O/P,3 PH & 1PH MCB PROTECTION 52 To study the speed control of DC motor by:(a) varying field current keeping armature voltage constant; and,(b) varying armature voltage keeping field current constant DC SHUNT MOTOR (FULL COPPER WINDING) .5 HP WITH BASE MOUNT FRAME 1 No VARIAC CONTROLLED 2 DC POWER SUPPLY ( 1 FOR FIELD & 1 FOR ARMATURE)DC VOLT & AMMETER DIGITAL………4 NosPANEL MOUNTED RPM METER………1 No.WHITE BAKELITE FRONT WITH CONN. DIAGRAM & WOODEN SAFETY BOX.METAL FRAME TABLE (Ply board with sun mica) CUM STAND FOR PANEL 53 Power Electronics Devices Trainer KitShould have Built in power supplyDC supply : +/- 12V, 500mA,Power supply 17V / 750mA,Regulated 13.5V/3A O/P mustbe provided as 12V Battery charging supply. Isolated DC supply +12V/ 300mA with isolated common.On board Inverter transformer of Primary : 230V & Secondaries 12-11-0-11-12/3AOn board Lamp load of 15W (100W) should be provided.AC supply : 230V AC line voltage must be made available on two banana 4mm socketsMust have Two pulse transformers of 1:1:1 are provided for isolation & supplying firing pulsesalong with required DC Power supply to experiment panel under test through 15 pin female ‘D’connector.R-L-C Load PanelMust have Load resistor of 10W / 40W --- 1no.Must have Centre tapped 3A choke 4mH/ 16mH each ----2nos.Must have Commutation capacitors of 10mF/100V -------4nos.Must have AC Paper capacitor of 4mF/440V ---1no. 54 PLC Trainer (EXPERIMENT 1-Use of simulation package for different function of PLC. EXPERIMENT 2- Verify function of logic gates by using PLC. EXPERIMENT 3- Write and verify ladder program for motor ON-OFF Control with two push button)HARDWARE SPECIFICATION:TTL Input Switches : 8 Nos,TTL Momentary Switches : 8 Nos., Proximity Switch : 1 No.,Optical Transducer (two state) : 1 No., Programmable LEDs : 8 Nos., Analog input 0 to 5V DC : 8 channels, Analog output 0 to 5V DC : 1 No., 4 to 20mA Transmitter : 1No., 4 to 20mA Receiver : 1No., Current Meter : 25mA FSD 1No.,Voltmeter : 10V FSD 1 No., Piezo Electric Alarm : 1 bit.Built-in power supply.Dedicated I/O interface card suitable for IBM computer suitable for ISA slot. SOFTWARE SPECIFICATION:This is a GUI based LADDER LOGIC SOFTWAREDRAG AND DROP (D&D) an instruction instead of typing an instruction. This eliminates errors in typing. All the instructions are displayed ON-SCREEN during Design time. Each and every element is directly addressed with their NAMES not by numbers or codes, which are very difficult to remember. Ex: At design time, you call a SWITCH#0 in your Ladder program by D&D the component called SWITCH#0, and that’s it, not by typing a few digits numbers or codes.Appropriate LIST boxes (input, output) open as you D&D an instruction in LADDER WORKSPACE.Ladder workspace is 24X100 instruction CELLs are available for your use.TOOL TIP features are available at the end of each instruction prompting you “what to do next”Very user friendly.Extensive ON-LINE HELP menu available.GUI based STATUS of the entire PLC is displayed during RUN TIME.Programs are saved, retrieved, edited by simply clicking on Menu list box.Extensive EDIT features are available. 55 Power Electronics Development TrainerSize of Breadboard : 172.5 mm × 128.5mmDC Power Supply :+5 V, -5 V 500 mA,+12V, -12 V 500 mA+15 V, 250 mA+35V, -35V, 250 mAAC Power Supply :18V-0V-18V ,0V-15VOn board Firing CircuitsFrequency range : 30Hz to 900Hz variableAmplitude : 12VPWM control of G1, G2, G3 and G4Duty cycle control of “Gate”Signal is 0 to 100%SCR Assembly : 4 SCRs 2P4M, 400V/2APower Devices : IGBT-G4BC20S, MOSFETIRFZ44N,UJT-2N2646, DIACDB3,TRIAC-BT136, PUT-2N6027Circuit Components on board : Electrolytic Capacitor 10µF, 63V,Electrolytic Capacitor 1µF, 63V ,Met. Capacitor 0.33µF, 63V ,Diode 1N4007, Inductor 220uH, 4.7µH, 10mH.Pulse transformer on board :2 nos. PT4502 1:1 and one is PT4503 1:1:1Load selector : 6 load resistances- 47E/7W,1K/1W, 1K/10W, 10K/10W,120E/5W, 2K2/2W.Test points : 10 nos (Gold plated)Power Supply (Mains) : 220V/110V, 50Hz/60HzIncluded Accessories :Bread boards : 2 nos.Connecting wires : 20 nos.2mm to 1mm Patch cords : 15 nos.2mm Patch cords (Red) 16” : 4 nos.2mm Patch cords (Black)16’’ : 4 nos.2mm Patch cords (Blue) 16’’ : 12 nos.Mains cord : 1 no.with i) Power Semiconductor Application Experiment Panel ii)CON / INV Panel iii)Triggering circuit / dv/dt Protection panel 56 ELECTRICAL & ELECTRONICS MEASUREMENT LAB (6TH SEM) 57 Digital LCR meterVariable measured- L,C,R and loss angle (D factor ) Measured frequencies: 1 KHz, 100KHzDisplay: 3⅟₂ digit , Resistance: 0 to 20 MΩ, 0.1 Ω , Capacitance: 0 to 20000μF, 0.1 pF Inductance: 0 to 20000 H, 0.1μH ,D factor: 0.01 to 8.0 with 1% error 58 Distortion Factor MeterFrequency : 20 Hz to 200KHz Distortion:0.1% to 100% f.s.d. in steps ,Input sensitivity: 100mV (r.m.s.), Input impedance: 1MΩ/160pF, Voltmeter range: 300μv to 300v f.s.d. in 13 range 59 To measure L & Q by Maxwell methodFULL BRIDGE WITH OSCILLATOR, LED NULL BAR GRAPH & AUDIO AMPR WITH SPEAKER INBUILT FOR NULL IND., DIGITAL MULTIMETER & CRO SIG. O/P INBUILT, IMPORTED (BOURNA) 10 TURN POT FOR NULL ADJ., DECADE INDUCTANCE WITH ROTARY SWITCH INBUILT, BACKLIGHT LED & WOODEN HARD BOX 60 To measure the unknown capacitance by Schering bridgeFULL BRIDGE WITH OSCILLATOR, LED NULL BAR GRAPH & AUDIO AMPR WITH SPEAKER INBUILT FOR NULL IND., DIGITAL MULTIMETER & CRO SIG. O/P INBUILT, IMPORTED (BOURNA) 10 TURN POT FOR NULL ADJ., DECADE INDUCTANCE WITH ROTARY SWITCH INBUILT, BACKLIGHT LED & WOODEN HARD BOX 61 To measure the unknown frequency by Wein BridgeFULL BRIDGE WITH OSCILLATOR, LED NULL BAR GRAPH & AUDIO AMPR WITH SPEAKER INBUILT FOR NULL IND., DIGITAL MULTIMETER WITH FREQ. COUNTER & CRO SIG. O/P INBUILT& CRO SIG. O/P INBUILT, IMPORTED (BOURNA) 10 TURN POT FOR NULL ADJ., BACKLIGHT LED & WOODEN HARD BOX 62 MICROCONTROLLER AND EMBEDDED LAB (5TH SEM) 63 Microcontroller Trainer Kit 1.Write a Simple Assembly Programs fora. Addition b. Subtraction b. Multiplication d. Division2. Write a Programs for (any two of the following)i. 4 x 4 Matrix Keypad Interfaceii. character based LCD Interfaceiii. Analog to Digital Conversion (On chip ADC)iv. Serial EEPROMv. Seven Segment LED Display Interfacevi. Interfacing With Temperature Sensorvii. Stepper Motor Interface8 BIT EMBEDDED MICROCONTROLLER TRAINERFEATURES•Single board design with various resources•Excellent training platform for embedded applications•Software development tools include assembler and ‘C’ compiler•Easy adaptability to different versions of microcontroller in the same family SPECIFICATIONS•Experimental board for 40 pin MCS51 and AVR family of microcontrollers•In-system programming (ISP) facility for many microcontrollers•Double RESET signal with manual key•Crystal frequency: 11.0592MHz•On-board RS232 compatible serial interface terminated in a 9 Pin D female connector•4×4 matrix keyboard•16×2 alphanumeric LCD connector (4-bit interface) and trimmer for contrast adjustment•Four 7-segment LED displays•I2C EEPROM (24Cxx)•Real time clock (DS1307) with lithium battery and SRAM•8-high current output port (500mA) for driving external loads•Two 12V sugar cube relays•Continuous tone piezo buzzer•Temperature sensor socket with thermostat functions•Four 8-bit A/D converter, one 8-bit D/A converter provided by PCF8591•All port-pins available on 10-pin box header•8 LEDs for easy logic state monitoring•8 input trigger switches using 8 push buttons•ISP programming with Flash ISP for AT89S51/52/8252/AVR•Infrared remote control receiver module IC supported•P89V51RD2BN•AT89S52 Installable software on CD•Programmers notepad : Free, open source, text editor•Flash ISP programmer software for 89SXX•Bascom basic compiler (demo version)•MIDE-51: An IDE for MCS-51 microcontroller•WinAVR : open source C compiler for AVR•Sample programs for peripherals DC 12V/500mA output power supplyEXPERIMENTS• Study of LED blink• Study of dancing light• Study of LCD display• Study of LCD-keyboard display• Study of 7 –segment display• Study of RC5 remote control test program• Study of analog to digital converter• Study of real time clock (RTC) 64 ADVANCE COMMUNICATION ENGINEERING LAB 65 To be familiar with the following network components:THIS WILL BE A FULL PACKAGE OF THE FOLLOWINGS:-** RJ5/CAT5CABLES 100 METERSRJ 45CONNECTORS 100 PCSCUTTER & CRIMPING TOOLS FOR RJ45/CAT-5CABLESCABLE TESTER/TRACKER…….. 4 PCSHUBS WITH ACCESSORIES & TOOL KIT NETWORK INTERFACE DIFFERENT CARD 66 COMPUTER NETWORK LAB 67 Network ComponentsCAT 5/5E/6 cable :100mtrs (Rs 2000/-), RJ 45 Connectors: 200pcs (Rs. 500/- )RJ 45 Crimping Tools: 05(Rs. 800/- each)LAN Cable Tester (RJ 45): 05 (Rs 1000/- each) 68 24 Port managed switchNo. of Ports: 10/100 Mbps 24 Ethernet ports, Switch Fabric: 32 Gbps, Form Factor: Rack Mountable,OS: LAN base Image, Console port: Availavble for configuration, Mac Address table: 4000 or higher, VLAN: Supported, MTU: 9100 with support for jumbo frames, Warranty: 3 years onsite comprehensive warranty including parts and labor plus onsite technical support with 24x7 69 24 Port Unmanaged switch24-port 10/100/1000Mbps Ethernet switch Wifi Router: 300 Mbps wireless router with 4 LAN ports and 1 WAN port 70 8 port HubExternal Power Supply, 8 Nos RJ-45 connectors for 10BASE-T/100BASE-TX,Ethernet Ports 8-Port, Capacity 1.6 Gbps, Wireless Speed 10 / 100 Mbps 71 Access points54 Mbps Access point for wifi network: No.of Channel: Dual channel for support upto 108 Mbps ( 2x54Mbps), Backbone connectivity: connect over Fast Ethernet through backbone switches, Security: Security enabled Wifi connectivity with option for Broadcast of SSID,Network:802.11 a/b/g/n network support, PoE: PoE enabled, Form factor: Wall or ceilling mountable with physical lock suppor. Warranty and support: 3 years on site comprehensive warranty including parts and labour plus on site technical support with 24 X 7 72 LAN TrainerEthernet (IEEE 802.3 wireless LAN (802.11),Token bus ( 802.4) Token ring ( 802.5), Data rate : 10/100 Mbps for ethernet, 1, 2, 5.5, 11 Mbps for wirless & LAN as per IEEE 802.11b, connectivity through RJ 45 connector. 73 Installation & commissioning of network(i) Laying ofOFC & CAT 6 Cable (ii) splicing (iii) Installation & network testing 74 INSTRUMENTATION AND CONTROL LAB (6th sem) 75 To measure displacement with LVDT ACTUAL LVDT WITHINSTRUMENTATION AMPLIFIERDC O/P WITH DIGITAL METER, 3and 1/2 digit LED display with polarity indicator, sensitivity of 10mV/mm in the range of 10mm. 76 To measure temperature with thermocoupleTHERMOCOUPLE SENSOR IN STEEL CASEELECTRIC WATER JAG.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR MERCURY THERMOMETER 77 To measure temperature with thermistorTHERMOCOUPLE SENSOR IN STEEL CASEELECTRIC WATER JAG.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR MERCURY THERMOMETER 78 To measure pressure with strain gauge STRAIN GAUGE SENSOR WITH WAIGHT LOADING SYSYTEM SAMPLE WEIGHTS.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR 79 To plot the Characteristics of RTD (PT-100)RTD 3 WAIR SENSOR IN STEEL CASEELECTRIC WATER JAG.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR MERCURY THERMOMETER 80 Temperature controller with on-off controller, Temperature controller with PI controller, Temperature controller with PID controllerTemperature controller with facilities for P, I, D and relay control blocks, Operating temperature: Ambient to 90°C, Separate controls for P, I, D channel gains,Two settings for relay hysteresis, Fast 25W oven fitted with IC temperature sensor, Forced cooling option to ready oven for next experiment, Digital display of set and measured temperature on a 3½ digit built-in DVM, 0-9999 sec, timer on panel for a convenient temperature response experiment, Buffered output for recorder 81 CIRCUIT THEORY LAB 82 Determine the permeability of magnetic material by plotting its B-H curveHysteresis Loop Tracer/ BH Curve apparatus220volt AC, 50Hz supply 83 Series parallel resonance of R-L-C cktKit for Series parallel resonance of R-L-C ckt: The Set-up consist of Power supply (with variable frequency), audio oscillator with digital readout, digital RMS meters and different number of inductors (smoothly variable), capacitors, Rheostat, patch cord & manual. 84 SWITCH GEAR LAB 85 Speed control of Induction motor 1ph by using SCR3Φ, 400V ac, 50HZ.,1HP, 1440 rpm. Speed control using ac back to back configuration of SCRs and to note Speed vs. Load Characteristics at open loop condition. This unit should consist of AC 3Φ Induction Motor (1HP) coupled with a (i) DC Shunt Generator (1HP) for loading and (ii) a DC Tachogenerator to be used for speed feedback control. A DC meter must be provided for displaying the speed of the motor from the Tachogenerator with suitable AC Ammeter and Voltmeter for the measurement (AE Make Panel Type or digital) Sheet Metal enclosure with powder coating paint must be provided. (with foundation & Experiment Table) 86 C.T. & P.T. testing trainer kit C.T. & P.T.testing trainer kit - Variable AC voltage source (0-220V)& variable AC current source (0-25A), CT for 25/5A, PT for 220/110V, Autotransformer for voltage & current adjustment, MCB protection, To determine Ratio error, Phase angle error of CT & PT, with Burden box. , polarity check indicator , range selector switch. 87 Induction type electromagnetic relay* Over Current (IDMTL Electro- Mechanical Type , Model CDG-11 or equivalent) Relay,*PSM, TSM setting* Auxiliary Relay,* Counter /Timer,* D.W. Transformer, * Variac,* Knife Switch,* DC power supply for DC auxiliary relay and the relay,* Portable Ammeter.Necessary panel for the complete set up with wooden (teak wood) table (4x3x2.5) 88 Air Circuit BreakerCut section model 89 Transmission line protection simulation KitOver Current, Earth Fault, Over Voltage, Under Voltage, Directional, Differential, Distance protection 90 POWER PLANT LAB 91 Diesel generator power plantmodel of small diesel generator power plant 92 Hydro power plantmodel of micro Hydro power plant 93 Horizontal axis small wind turbinemodel 94 CSP plantmodel 95 MEASUREMENT LAB 96 Kelvin double bridgeCompletely self contained, stand alone unit with built in power supply, required meters, Standard Resistance, wooden bench, high sensitivity spot light type galvanometer, connecting patch chords and operating manuals. 97 RENEWABLE ENERGY LAB 98 Renewable Energy Labsolar PV plant- Model 99 Renewable Energy Labvertical axis small wind turbine- Model 100 ELECTRIC MACHINE LAB 101 VoltmeterVoltmeter (M.I type) 0-150V/300V/500V 102 VoltmeterVoltmeter (M.I type) 0-20V/50V 103 AmmeterAmmeter (M.I type) 0-5A/10A/20A 104 AmmeterAmmeter (M.I type) 0-1A/2A/5A 105 MultimeterAnalog Multi-meter of ISI marked: DC : 0-200 mV/ 1000 V & 0- 2mA – 10 A,AC : 0 – 200mV/1000V &0-2 mA – 20 A, Resistance : 0 – 200 Megaohm, with shock proof protection & other facilities and operatingmanuals. 106 MultimeterDigital Multi-meter of ISI marked: DC : 0-200 mV – 1000 V & 0-2mA – 10 A,AC : 0 – 1000 V & 0- 2mA– 20 A, Resistance : 0 – 200 Megaohm, with diodetesting, data hold, shock proof protection , auto power off etcfacilities and operating manuals. 107 WattmeterDynamometer Wattmeterof ISI marked : Low Power Factor ( 0.2 ) : Current Rating : 5/10 A , Voltage Rating : 150/300 / 600 V , with anti-parallax mirror , 120 mm scale length , knife edge pointer, mouldedBakelite body, portable. 108 VoltmeterVoltmeter (PMMC type) 0-150V/300V 109 AmmeterAmmeter (PMMC type) 0-2A/5A 110 StarterDC 3-point Starter : 220 V DC , 15 A 111 StarterDC 4-point Starter : 220 V DC , 15 A 112 DC Power SupplyDC Power Supply : Input : 415V, #-Phase AC, 50 Hz;Output : 220V DC , 5 KW of a standard make . 113 RheostatRheostat with sliding Jockey : 100 Ohm , 5 A 114 RheostatRheostat with sliding Jockey : 500 Ohm , 5 A 115 Digital Energy MeterDigital Energy Meter of ISI marked: Three Phase AC , 440 V , Maximum 30 A, 50 Hz with operatingmanual. 116 Digital MeggerDigital Megger for measuring insulation resistance of ISI marked: 250 / 500 V, Maximum 200 Mega ohmwith operating manual 117 VariacSingle Phase Variac of ISI marked : Input:– 230 V AC, Output : 0 – 270 V AC , 1 KVA, 50 Hzof a standard make 118 VariacThree Phase Variac of ISI marked : Input:– 415 V AC, Output : 0 – 500 V AC , 3 KVA, 50 Hzof a standard make 119 Clamp on MeterClamp on Meter of ISI marked : Digital type : For measuring Voltage ( AC/DC ), Current ( AC/DC ) , resistance, Power & Power Factor with operating manuals 120 Phase Sequence IndicatorPhase Sequence Indicator of ISI marked : 50 – 500 V AC, 25 – 60 Hz 121 Frequency MeterFrequency Meter of ISI marked: Digital Type : 240 V, 47 – 99 Hz 122 TransformerSingle-Phase Transformer : 1 KVA , 230 V/115V , 50 Hz( Air Cooled) 123 TransformerThree-Phase Transformer : 3 KVA , 415/230 V , 50 Hz 124 3-Ph Resistive LoadThree phase resistive load : 400 V , 6 KW 125 3-Ph Inductive LoadThree phase inductive load : 400 V , 3 KW 126 3-Ph Capacitive LoadThree phase capacitive load : 400 V , 3 KW 127 3-Ph StarterStar Delta automatic starter for 3 Phase,400 V, 5 Hpmotor 128 3-Ph DOL StarterDOL & Auto -Transformer Starter : 3-phase AC , 400V, 10A, 50 Hz 129 StroboscopeDigital Stroboscope - 10,000 rpm 130 DCGenerator Voltage build UPSupply, Installation , Commissioning & Testing with suitable ISI markedammeter, voltmeter, starter, rheostat , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :For Building up Voltage in DC Generator ( Open Circuit / Saturation Characteristics: DC Shunt Motor of ISI marked : 2HP or 5HP, 220 V. Machines will have to be set on M.S.Channel base with suitable footing/fixtures and screws etc. and operating manual isalso must.(with foundation & Experiment Table) 131 Brake test in DC Series Motor Supply, Installation , Commissioning & Testing with suitable ISI markedammeter, voltmeter, starter, rheostat , digital tachometer , Spring balance & loadings, protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :For Brake test in DC Series Motor& load Characteristics: DC Series Motor of ISI marked : 2HP, 220 V.Machineswill have to be set on M.S.Channel base with suitable footing/ fixtures and screws etc. and operatingmanual is also must.(with foundation & Experiment Table) 132 Speed Controlof 3-Phase Squirrel cage Induction motorSupply, Installation , Commissioning & Testing with necessary & suitable ISI marked meters such as ammeter, voltmeter, frequency meter , starter, protective devices and all other accessories mounted on a standing panel board as per following specification :For Speed Controlof 3-Phase Squirrel cage Induction motorby – (i) volt /freq control method : Three phase Squirrel cage induction motor : 2HP, 400V with v/f controller.Machineswill have to be set on M.S.Channel base with suitablefooting/fixturesandscrewsetc.includingtheoperating manual.(with foundation & Experiment Table) 133 Load Test of an Alternator & % regulation at various loads with Unity Power factorSupply, Installation , Commissioning & Testing with suitable ISI marked ammeter, voltmeter, starter, star connected load , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :For Load Test of an Alternator and Determination of%-age regulation at various loads with unity power factor : DC Shunt Motor of ISI marked : 3HP, 220 V , AlternatorISI marked: 2 KVA, 415 V , 50 Hz.Machineswill have to be set on M.S.Channel base with suitable footing/fixtures and screws etc. and andoperating manual is also must.(with foundation & Experiment Table) 134 Measurement of Slip of 3-Phase induction motorSupply, Installation , Commissioning & Testing with suitable ISI marked meters such as ammeter, voltmeter, frequency meter, stroboscope etc , starter , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :Measurement of Slip of 3-Phase induction motor by –(i) Stroboscopic& (ii ) Tachometer methods and reversing the direction of rotation of the motor : Three phase squirrel cage induction motor of ISI marked: 2 HP , 415 V , 50 Hz .Machineswill have to be set on M.S.Channel base withsuitable footing/fixtures and screws etc. and and operating manual is also must.(with foundation & Experiment Table) 135 Synchronization of two 3-Phase alternatorsSupply, Installation , Commissioning & Testing with suitable ISI marked meters such as ammeter, voltmeter, frequency meter etc , starter , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification : Synchronization of 3-Phase alternator ( 2 SETS ) by– (a) Three Lamp & (b) Synchroscope Methods : DC Shunt Motors of ISI marked : 5HP, 220 V ,Alternators of ISI marked: 3 KVA, 400 V, 50 Hz.Machineswill have to be set on M.S.Channel base withsuitable footings/fixtures and screws etc. and and operating manual is also must.(with foundation & Experiment Table) 136 POWER SYSTEM LAB 137 KIT FOR STUDY OF ACTIVE & REACTIVE POWERWITH SIMULATIOL KIT & LAPTOPStudy of Active & Reactive power with simulator Kit and Laptop with appropriate software, The kit should consist of variable Inductive & Capacitive load to observe change in active & Reactive power 138 MODEL OF VARIOUS TYPES OF TURBINES USED IN POWER GENERATING STATIONSModel Piece of each type of Turbine 139 PYRANOMETERMEASUREMENT OF SOLAR RADIATION BY PYRANOMETER 140 PHOTO VOLATIC SYSTEM USED IN STREET LIGHTWITH SOLAR PLATE,PV CELL,BATTERY,CHARGER 141 STUDY OF POWER SYSTEM OF 6.6 KV/400 V SUBSTATION USED FOR A HOUSING CONPLEXMODEL 142 D.C NETWORK ANALYSERD.C NETWORK ANALYSER FOR STUDY OF DIFFERENT TYPES OF FAULTS 143 DIFFERENT TYPE OF EXCITATIONS SYSTEM USED IN ALTERNATORSTATIC EXCITER,SHAFT MOUNTED,ROTATNG TYPE EXCITER & Brushless exciter ( Model only) 144 MISCELLANEOUS 145 MOTOR-ALTERNATOR SET FOR SYNCHRONISATION OF TWO ALTERNATOR WITH SYCHRONISING PANEL INCLUDING CHECK SYNCHROSCOPE & BULB ARRANGEMENT TO PERFORM TWO BRIGHT ONE DARK LAMP METHOD1.TWO SET OF D.C MOTOR 2.5 KW,230 VOLT,3000 R.P.M WITH SPEED CONTROL ARRANGEMENT 2. TWO SET OF 1 KVA,3 PHASE,440 VOLT,3000 R.P.M ALTERNATOR WITH BASE MOUNTING & EXCITATION SYSTEM. 146 PlierPlier of good quality 147 TesterTester Screwdriver of reputed brand 148 Screwdriver setScrewdriver set of reputed brand
Contract Date: Mar 12, 2026 Contract Value : 33.87 Lakh
Government Departments No of Bidders 9
West Bengal View Result →
14.
Educational and Research Institute #9814276 AOC
Tender For Supply And Installation Of Different Electronic Components And Sensors , For Supply And Installation Of Different Electronics Components And Sensors , Drill Machine , Drill Bits - Carbide Pcb Drill Bits With Diameter 0.7 Mm , Drill Bits- Carbide Pcb Drill Bits With Diameter 0.95/1 Mm , Drill Bits- Carbide Pcb Drill Bits With Diameter 1.2 Mm , Drill Bits- Carbide Pcb Drill Bits With Diameter 1.5 Mm , Drill Bits- Carbide Pcb Drill Bits With Diameter 3 Mm , Copper Clad 0.8 Mm (18X24 Inch) , Double Sided 1.6 Mm Clad (12X10 Inch) , Press Iron , Solder Station , Conformal Coating , Multifunction Pcb Cutting Tool , Desoldering Iron Machine , Soldering Smoke Abrosber , Soldering Desoldering Hot Plate , Multifunction Soldering Helping Stand , Dual Op Amp Lm 358-On , Timer Ne555-Ti , Timer Lm7555 , Precision Op Amp Op07-Ti , Darlington Array Uln2003-Ti , Reference Diode Lm336-2.5V , Adjustable Reference Tl431 , Optoisolator Moc3031 , Audioamplifier Pam8403 , Serial In Parallel Out 74Hc595 , Parallel In Serial Out 74Hc165 , Usb To Serial Converter Ch340 , Npn 100 Ma Bc547-Cdil , Pnp 100 Ma Bc557-Cdil , Npn 800 Ma Bc337-Cdil , Pnp 800 Ma Bc327-Cdl , Npn 1.5A Bd139 , Pnp 1.5A Bd140 , Npn 10 A Mje3055-St , Pnp 10 A Mje2955-Fs , Npn High Frequency 2N3904-Bc , Pnp High Frequency 2N3906-Bc , Npn 2N2222-Bc , N Channel Mosfet Irf540-Ik , P Channel Mosfet Irf9540-Fsc , Triac Bt136 , Temperature Sensor Lm35 , Microphone Czn-15E , Thermistor 150O , Thermistor 1K? , Ldr 3Mm , Ir Photodiode 3Mm , Slotted Optoisolator Moc-7811 , Optoisolator 4N35 , Ir Receiver Tsop0038 , Tilt Sensor Sw520d , Rectifier Diode 1A 1N4007 , Schottky Diode 1N5819 , High Speed Diode 1N4148 , Zener Diode 3.3V/500Mw , Zener Diode 5.1V/500Mw , Led Red 5Mm Red Colour (5 Mm) , Led Red 3Mm Red Colour (3 Mm) , Led Green 5Mmgreen Colour (5 Mm) , Ledblue 5Mmblue Colour (5 Mm) , Ledrgb Cc Rgb Cc , Ledcool White 5Mm , Ledir 5Mm , 7 Segment Display Cc 4 Digit , Packaging Material , Hall Effect Sensor , Magnetic Sensor , Amperometric Three Electrode Sensor , Vacuum Pump Suction Sensor , Spin Coating Unit Servo Motor With Other Accessories , Current Sensor , Color Sensor Tcs3200 , Color Sensor As7341 , Mini Wireless Development Module With Accessories , Esp32 Dash C6 Class Wireless Microcontroller Development Board , Esp32 Dash S3 Sense Class Wireless Microcontroller Development Board , Rechargeable 3 Point 7V Lithium Battery Along With Holder And Charger , Digital Multimeter , Soldering Iron 25W With Stand , Solder Wicks , Solder Wire , Soldering Flux , Lorawan Co2 Coma Temperature Coma Humidity And Air Pressure Sensor , Power Bank 20000 Mah With Cable , Tds Sensor Microcontroller Compatible , Ph Sensor Microcontroller Compatible , Bread Boards Mini , Aht2415c Temperature And Humidity Probe , Jumper Cables Male To Male 20 Cm Each 40 Pcs Each , Jumper Cables Male To Female 20 Cm Each 40 Pcs Each , Jumper Cables Female To Female 20 Cm Each 40 Pcs Each , Nitrogen Dash Phosphorus Dash Potassium Dash Calcium Npk Calcium Sensor , Ldr (Light Dependent Resistor) , Ldr Sensor Module Lm393 Coma 4 Dash Pin , Dc Motor Small Coma 5V Dash 12V , L293d Motor Driver Ic , Resistors 10 K? , Servo Motor Sg90 Oblik 5V , Mpu Dash 9250 9 Dash Axis Sensor , 220V Led Bulb With Insulated Holder And Insulated Ac Power Cable With Molded 3 Dash Pin Plug , Iot Training System Oblik Learning Kit With Wooden Enclosure , Temp Oblik Humidity Coma Light Intensity Sensor And Pressure , Par Sensor Based On Lorawan , Cooling Fan Automation Based On Temp Andhumidity , Level Sensor Dash Water Management , Pump Controller , Lorawan Water Quality Sensor Converter , Water Turbidity Sensor , Dissolved Oxygen Sensor , Water Electrical Conductivity Sensor , Water Ph Sensor , Water Oblik Nutrient Npk Sensor Based On Lorawan
Contract Date: Mar 25, 2026 Contract Value : 6.41 Lakh
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Ref. Documents Contract Value : 50.00 Lakh
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Ref. Documents Contract Value : 3.79 Crore
Government Departments No of Bidders 4
Chhattisgarh View Result →
17.
Educational and Research Institute #9630538 AOC
Bids Are Invited For Soldering Irom , Soldering Stand , Small Screwdriver , Wire Cutter , Hacksaw , Extension Board , Ic Tester Machine , Digital Voltmeter For Bread Board , Digital Ammeter For Bread Board , Scientific Calculator , Battery Connector Of Bread Board , Jumper Wire Male To Male , Bread Board Wire , A To B Cable , Usb Male To Female Cable , Pcb For Soldering Practice , Perforated Pcb , Bread Board , Bread Board Power Supply , Mercury Vapour Lamp , Sodium Light Bulb , Green Laser Light , Red Laser Light , Ppt Pointer , Ic 7400 Nand , Ic 7402 Nor , Ic 7404 Not , Ic 7408 And , Ic 7410 Triple 3 Input Nand , Ic 7432 Or , Ic 7486 Xor , Ic 7474 Dual D Flip Flop , Ic 7478 Jk Flipflop With Clear And Preset , Ic 7430 8 Input Nand , Ic 74266 Quad Xor And Nxor With Open Collector Outputs , Ic 741 Op Amp , Ic 358 Dual Op Amp , 555 Timer , Ic 7805 Voltage Regulator Plus 5V , Ic 7905 Voltage Regulator Minus 5V , Ic 317 Adjustable Voltage Regulator , Uln 2803A Darlington Transistor Array , Dac Mcp4921 Digital To Analog Convertor , Comparator Generic Or Specific Ic , Multiplexer , Demultiplexer , 16 Pin Ic Casing , 8 Pin Ic Casing , Cnc Shild For Arduino , Rotary Encoder For Arduino , Current Sensor For Arduino , Photo Diode , Tracing Paper , Insulation Tape , Hand Wash Refile , 256 Gb Pen Drive , Mouse Pad , Chart Paper Different Color , Scale Plastic 12 Cm , Eva Sheet A4 Different Color , Pencil , Paper Cutter , Small Electric Motor , Cycle Walto , Set Square Both Type Small Size Coloured , A3 Size Drawing Sheet , Joot Rope , A4 Size Drawing Sheet , Pen Drive , Hdmi To Vgi Connector , A4 Size Different Colour Sheet , Black Sheet , Oil Pastel Colour , Collered Pencil , Pastel Pencil Different Colour , Loose Pebbles Different Colour , Marble , Plastic Or Wooden Sticks 12Cm Height Each , 3D Shapes Different Size , Seizer Big Size , Seizer Small Size , Mirror , Scrap Paper Big Size , Scrap Paper Small Square Size , Forex Sheet 2X2 Feets , Office Bag , Water Dispenser , First Aid Kit , Hats , Gents Shoes , Sari Of Various States Marathi South Indian Assami Kolkata , Mop And Backet , Doormat Total Quantity : 2585
Contract Date: Ref. Documents Contract Value : 2.08 Lakh
Government Departments No of Bidders 4
Madhya Pradesh View Result →
19.
Defence #9545191 AOC
Tender For Provision Of Solar Power Plant At Sevoke Mil Station Under Ge Sevoke Road.; 2 Design, procurement, erection, installation, testing and commisioning including connecting to local utility grid; Grid connected solar photovoltaic plant 0.8 MW output peak capacity with net billing arrangement including Solar Photovoltaic Modules,DC Cabling, Module Mounting Structures (suitable for ground mountingwith and including Soil Investigation as per OEM recommendation, RCC foundation framed structure and other connected civil work duly vetted by IIT / NIT), Array Combining Boxes, ACDB, DCDB, Lightining Protection of SPV modules and other accessories, String Inverter as Power Conditioning Unit, Weather Station and Data Monitoring system (SCADA) all as per detailed specifications given in tender documents, latest MNRE/SECI/NISE/IREDA guidelines and directions, meeting the Make in India (DCR), consisting of all requisite accessories (BOS-Balance of system) and including the following main components (NOTE : The work shall be executed directly by OEM only through contractor.) Item Continued as 1.01 to 1.45 3 (A) Photo Voltaic Module: Mono-crystalline Silicon Bifacial Solar Photovoltaic Modules of minimum 550 Wp(module power and number of modules to be selected according to available area), having cell efficiency more than 20% under standard conditions, form fill factor more than 0.76, plant performance ratio > 75%, made of high transmitivity glass front surface and it shall give high encapsulation gain (transmittance above 90% and bending less than 0.3%). The modules shall have the following features :(a) The electrical parameters of SPV modules under standard test condition of irradiance 1000W/sqm, AM 1.5 Spectrum and temp 25 degree Celsius shall be as under : (i) Max Peak Power Pmax : 550 Wp or more (ii) Voltage at Max Power : > 40 V (iii) Current at Pmax :> 10A 4 (iv) Short Circuit Current :> 12A (v) Open Circuit Voltage :> 47 V (vi) Module Efficiency : > 20%(b) Rated output of the modules shall have positive tolerance of 3-5% and no negative tolerance is allowed.(c) It shall perform satisfactorily in RH 85% with temperature up to +85 degree C and should withstand wind of 200 kmph on the surface of panel.(d) PV modules shall be warranted for their output peak watt capacity, and it shall not fall of its initialvalue below 90% in first 10 year end and 80% after the end of 25 years.(e) Each module shall have RFID tag encapsulated with solar cell bearing following details (i) Name of Manufacturer of SPV Module (ii) Name of Manufacturer of Solar Cell 5 (iii) Month and year of Manufacturing (separately for cell and module) (iv) Country of Origin (both cell and module) (v) Peak wattage, Im, Vm and fill factor of the module (vi) Date of year of obtaining IEC PV module qualification certificate including the test lab issuing IEC certificate. (vii) Unique serial no of model no of module (viii) IV curve of module(ix) Other relevant information on traceability of solar cells & modules(f) The temperature coefficient of power for the module shall not be more than 0.50% per degree Celsius.(g) The module must have bypass diode of suitable capacity.(h) PV module must confirm to latest edition of IEC 61215/ IS 14286. In addition the modules must confirm to IEC 61730 Part I and II for construction and testing & safety qualifications and confirming to IEC 62804 PID.(j) It shall also be in conformity to latest minimum technical specification issued by MNRE/IREDA/SECI/NISE/ALMM from time to time. Modules should be of MNRE/IREDA/SECI/NISE/ALMM approved companies and as per latest IEC/IS standards. 6 (k) RFID reader is to be provided by contractor(l) Both PV cells and SPV modules shall be made in India (DCR).(m) Each structure should have angle of inclination as per the site conditions to generate maximum power. However, to accommodate more capacity the angle inclination may be reduced to 10 - 13 Degree until the plant meets the specified performance ratio requirements.(n) Fire Points with Fire extinguisher liquefied CO2 gas of capacity 10 kg and adequate qty confirming to relevant IS or ISI mark complete as recommended by manufacturer deemed to be included in the unit rate quoted.(o) Danger Board and Rubber mat as recommended by manufacturer deemed to be included in the unit rate quoted.(p) S&F Pressure Booster pump electrically operated with minimum 3 HP 02 Nos (Running+ standby) three Phase AC Supply motor and having head not less than 20 mtr, including PCC foundation civil wokrs and necessary cable required for connection in drawn in PVC conduit heavy duty/ DWC/Electrode pipe from existing nearest point to the motor starter panel including motor starter suitable capacity,PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm/50 mm/32 mm/25 mm inner dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brass threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches with necessary exavation, removing and returning filling work and including all accessories from the new PVC tank cap 10000 Ltrs install at proposed site for cleaning of entire solar power plant system.(q) SPV Panel is to be fixed in such a way that lower portion of the Panel remains atleast above 1.5 mtr of finished reflecting surface and cost deemed to be included in the quoted rates. 7 (B) Junction Boxes: Junction boxes of suitable Nos (as per design)/OEM recommendations inputs and suitably rated out put having separate DCfuses for both (+)&(-) on input and isolator on output terminal for each string.Each junction box must have as pare input terminal.The junction boxes shall be dust and vermin proof and water proof made of FRP/ Thermo Plast with IP 65 protection in compliance with IEC 62208 and shall be UV resistant, fire retardant. It shall have surge protection and maintenance free earthing as per relevant standard. The junction box shall have suitable arrangement of the following: (a) The strings are required to be connected to the copper bus bar through individual fuses. (b) Provide arrangement for disconnection (DC dis-connection switch) for each SJB/ SCB. (c) To provide a test point for each sub group for quick fault location and to provide group array isolation. (d) Each array box shall be of relevant IEC standard. (e) Each array junction box shall have suitable bypass & reverse blocking diodes for minimum DC blocking voltage of 1000V with suitable arrangement of its connection. Reverse blocking and bypass diodes shall work for extreme temperatures and shall have efficiency of 99.98% confirmed by appropriate IEC standard. 8 (C) DC Cables: Suitable size of XLPE insulated tinned Copper cable (min 10 sqmm) of solar grade, 1100 Volts and UV resistant for outdoor installations confirming to IEC : 60227/15694 & 60502/ IS : 1554 (Pt I&II)) and shall be as under : (a) All cables and connectors must be as per IS/IEC standards and shall be able to withstand harsh environmental conditions including high temperature, UV radiations, rain, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS. (b) All the cables / wires shall be provided with UV resistant printed ferrules for DC wires. (c) The size of the cable shall be such that average voltage drop at full power from PV module to inverter shall be less than 1.5%. (d) Cable batch No., Drum No, IS code and size and make shall be mentioned on every one meter or as per OEM practice. (e) The wiring of the module interconnection shall be in UPVC/HDPE pipe of suitable size. (f) The cost of interconnecting DC Copper cable, MS cable trays, MS cable trays suitable to accommodate Solar grade cables from SPV module to inverter are included in the item. 9 (g) Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain ant type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore will be repaired and make good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes, exavation, removing, return filing, channel, any type of metal work is not measured and paid separately under relevant items.(D) Module Mounting Structure (MMS) (Suitable for ground mounting on any type of soil condition) :Design, procure, fixing, support structure made of hot dipped galvanised steel with min 85 micron thickness including necessary PCC / RCC foundation and associated work (cutting, grounding, PCC filling, disposing waste material,etc., complete) and fixing mounting arrangement suitable for SPV modules so as it can with stand wind speed of 170 km per hour & minimum yield strength off 250 MPa. The mounting structure is to be installed on ground. Mounting structures to be so designed that maximum load is directly on ground. It shall also observe minimum space without sacrificing the out put of SPV panels & adequate spacing between the arrays shall be available for easy cleaning and maintenance. Nuts, bolts, protected from the atmosphere and weather mounting structure shall have to be adequately of Stainless Steel of grade SS316. 10 NOTES :- (a) Two numbers of anti theft fasteners of Stainless Steel on two diagonally opposite corners of each module shall be provided. (b) Module mounting structure shall be fitted to provide maximum generation. (c) MMS design shall be supported with Staddpro Report vetted by Third Party (Gov Institute) and submitted for the approval of the Accepting Officer. (d) The height of approved design MMS for solar power plant shall be as per latest MNRE/IREDA/SECI/ NISE guidelines. (e)Minimum grade of RCC M-25, design mix (using 20mm graded crushed stone aggregate includingTMT bar as per design, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete and other connected works as per design and OEM recommendation. Civil work shall be designed through approved consultant of MES as per latest MNRE/IREDA/SECI/ NISE guidelines and vetted by IIT / NIT.(E) Lightning Protection forentire Solar Power Plant (i.e PV Array, Inverter etc) : Design, procure and fix lighting arrestor system confirming toIS/ IEC-62305(Part1-4)on the ground. The air terminal shall be fixed at the top of MS pole with base so as to beat least two meter above the pole to be protected. Its height above 9 mtr level shall be depend upon the level of protection and protection radii required. 11 NOTES :-(i) The cost of all equipments, MS Pole, Copper strip upto earth test point,LA, etc., shall be deemed to be included in this item. (ii) The cost of sufficient earthing for lightning protection is also included in this item to be provided by Engr-in-charge. and no extra payment will be made to the contractor on this account (iii) The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account. In case of any dispute, decision of Engr in charge will be final, conclusive and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474). Earth resistance shall not be more than 3 Ohms. (iv)Separate LA arrangement & the design document of the same shall also be submitted. (v) The protection against induced high voltage shall be provided by the use of metal oxide varistors and suitable earthing such that induced transient find and alternate route to earth. (vI) SPV Power Plant shall be provided with lightening and over voltage protection. (vii) Internal surge protection shall consist of three MOV type surge-arrestors connected from +ve abd +ve terminals to earth (via Y arrangement) 12 (F)Power Conditioning Unit: Procure, fixing, testing and commissioning of minimum 4 (Four) unitswith overall not less than 800 KW output on 11 KV AC supply, Solar-power inverter suitable for without DC power of Solar PV module/ array with AC output further feeding to grid confirming to IEC:61683 for efficiency, IEC:62109-1 or equivalent for safety and IEC:62093 for reliability. The input DC & output AC technical specification of Inverter are as under :Input (DC) (a) Max Absolute DC input Voltage : 1000 V (b) Start-up DC input voltage : 200 - 500 V (Default 420V) (c) Operating input DC voltage range : 200 - 1000 V (d) No of independent MPPT : One (e) MPPT input DC voltage range at Pacr : 180 - 1000 V DC (f) Max input DC Current : As per design. (g) AC grid connection type : 3Phase (4W + PE) (h) AC output power : As per design. (j) Max AC output Apperant power : As per design. (k) Max AC output Current : As per design. (l) Max AC fault current : As per design. 13 (m) Nominal Output Voltage : 800 Volts AC 3phase or as per the design of Solar Stepup Transformer (n) Output voltage range :± 10% (o) Output Frequency : 50 Hz ± 3Hz (p) Power factor : > 0.99 (q) Harmonic Distortion Current : < 3% (r) Efficiency : > 98% (s) Standby operation consumption : < 1.5 W(t) Operating temperature upto 85 degree centigrade (u) The Copper based inverter shall have minimum IP-67 protection, ground fault monitoring, reverse polarity protection, anti-islanding, DC reverse polarity, AC and DC short circuit current and over current, AC and DC over voltage and over temperature. 14 (v) The inverter shall adjust voltage and frequency levels to suit the grid. (w) The inverter shall be self commulated with Pulse Width Modulation (PWM) technology and shall be capable of synchronise maximum with in one min. (x) Maximum Power Point Tracker (MPPT) confirming to IEC 62093 shall be integrated in the inverter to maximise the energy drawn from the PV array (y) Monolithic design of inverter is not permitted. (z) Shall have anti-Islanding features. (aa) The inverter shall have suitble nos of protected inputs (asper design) and outgoing shall be protected by ACB/MCCB. (ab) The inverter should have MODBUS, PROFIBUS, ETHERNET common ports. (ac)The inverte rshall include appropriate self protection and self diagnostic features to protect itself and the PV array fromthedamageintheeventof invertercomponent failureor fromparametersbeyondtheinverterssafeoperatingduetointernaland/orexternalcauses. Invertershallhaveprotectionarrangementagainst ground leakage faults, over voltage, (SPD) & over current. Inverter shall have arrangement for adjustment for adjusting DC input current and shall trip against sustainable fault down stream and shall not restart till fault is rectified. (ad) The inverter should have provisions of Galvanic isolation, anti-islanding protection (IEEE 1547/UL 1741) equivalent IS and lightening. (ae) PCU must have the feature to work in tandem with other similar PCUs and be able to be successively switched ON and OFF automatically based on solar radiation variations during the day. (af) Minimum Warranty of Inverter- 12(Twelve) Years and defect liability period deemed to amended accordingly for the said item. 15 (G)ACDB : Outdoor type powder coated weather proof,vermin proof made out of CRCA sheet front open able door, lockingarrangement, including suitable working space in DCDB busbar chamber, cable box chamber including Copper busbar of designed capacity /bus raisers suitable capacities with PVC sleeves/tape RYB colour for phases identification, including all bus raiser shall be extend upto cable box chamber fixed on fibre insulation for RYB & neutral to all out going cable, confirming to IP-65 and fixed on wall / floor with control wiring with comprising cable gland brass, copper lugs etc. and comprising the following as per design :- (i) MCCB 4Pmicroprocessor based for outgoing (ii) MCCB 4Pmicroprocessor based for incoming (iii) AC type 2 Surge Protection Device (iv) Spreader Terminals as per requirement (v) Multifunction meter (vi) CT of suitable ratio(vii) Copper busbar chamber (ix) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 16 (H) DCDB:- Outdoor type powder coated, weather proof, dust proof,vermin proof made out in CRCA sheet front open able door, looking arrangement, including suitable working space in DCDB busbar chamber,cable box chamber including copper bus raisers with PVC sleeves/ tape RYB coloursfor phase identification, including all bus raiser shall be extend upto cable box chamber, confirming to IP-65 and fixed on wall /floor with contral wiring with comprising cable gland brass, copper lugs etc. (i) MCCB as per requirement (ii) Fuse as per requirement (iii) Copper busbar chamber. (I) Weather Monitoring System Pyranometer : The pyranometer (ISO 9060 classification ) alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specifications of the pyranometer shall be as follows :- (i) Spectral response : 031 to 2.8 micron,(ii) Time response (95%). Max 15 second 17 (iii)Nonlinearity + 0.5% (iv) Temperature response : - 2%(v) Tilt error <+/- 0.5% (vi)Zero offset themal radiation +7W/Sqm (vii) Zero offset temperature change + 2 W/Sqm(viii) Operating temperature range - O °C to 80°C(ix) Non stabillity Maximum - 0.8%,(x) Resolution minimum +/-1 W/Sqm (xi)Output Analog 4.50mA (xii) Digital RS 485(xiii) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 18 (J)Balance of System(BOS) Items/ Components:TheBOSitems/componentsof theSPVpowerplants/systems deployed under this project shall conform to the latest edition with certificate of IEC or equivalent BIS Standards/MNRE specifications/ as specified in Para 1.01 of Minimal Technical Requirements/ Standards for SPV System/Plants to be deployed during this financial year under the programmes of MNRE available on MNRE website as on last date of quoting of tender. Notes:(i) The contractor must visit the site before quoting the rates for this item to assess the site condition so as to decide up on location and layout of SPV, placement of inverter, length of DC cables, lightning arresters, etc., complete. (ii) The contractor shall submit complete scheme including electrical diagram of the work, schematic diagram, SPV module layout, placement of LAs, Civil work, etc., complete as per IREDA/ SECI/NISE/MNRE/ALMM latest guidelines as applicable, Relevant IEC/IS norms to the GE for approval with in one month of date of commencement of the work. (iii) The rate quoted is deemed to be inclusive of the all protection system including surge, lightning arresters and necessary earthing all as specified and directed. 19 (K) Remote monitoring system (SCADA) for solar power plant complete with all electronic andelectricial partswith andincluding all necessary software and hardware etc to make fully functional connected to LED monitor (55 inches) with complete plant parameters as required and operate the system from remote and Other Accessories includingandThe system will be controlled from the main control room where all the data from different parts of the plant shallbe received, analyzed and action taken either manually or on auto as per the system design by OEM . The SCADA shallhave remote monitoring capability comprising with the following Items and with and including all connectedaccessories as per OEM recommendation complete:(a) Main SCADA control wall mounting panel complete with fixing arragnment like nut bolt, washers suitable size and connected items. (b) LED Moniter (55. inches) with mouse, key board, CPU (Minimum 1 TB storage alongwith 12 GB RAM, i7 processor), key pad and single phaseUPS 10 KVA with 12 Volt battery, 14400 Ah battery bank with rack and required battery backup should not be less than 4 Hrs inside control room.(c)“SCADA System shall be audited for Cyber Security by CERT certified firms at the time of commissioning. Subsequent cyber security audit shall be carried out after every 03 years and cost of audit and rectification shall be born by the contractor” 20 The Contractor shall provide following defined user access levels, unless otherwise instructed by the Engineer-in-Charge: -• Normal viewing only (default level) The default level shallpermit users to view al displays except those specifically assigned to a higher level of access.• Dally Access The daily access level shall allow viewing (ie default an printing at trend displays.• Operator Level (Remote Control) The operator level shall permit authorised users to access lower levels a and to carry out the following actions:- Perform control actions Acknowledge alarmsEnter or modify manually-entered data for inclusion in thereports.• Monthly and Yearly Data Archiving The level shall permit authorised users to access lower levels and shall provide the facility to download specific data to long ten data storage for archive purposes(d)The SCADA software shall be of a proven design and reliable, and conforming to industrial standards and shall: -• Support multiple makes of RTU/ Microprocessor controller/ transmitters and models and provide required software features needed to easily adapt a device whichshall not be supported as standard to the SCADA system. 21 • RTU/ PLC/ Microprocessor base controllers and transmitters shall have an expandable architecture and scalability to provide future capacity increases in SCADA system as well as meet present needs of the administration, provide multi-level security and password mechanisms to prevent use of the system by unauthorised persons. The access privilege of authorised users shall be defined separately and permission shall be provided to the users only to access areas concerning them, provide an on-line operatingenvironment.• Adding a new RTUI Microprocessor based Controller to the SCADA system or changing configuration of the existing RTUs/ Microprocessor based controller shall not result in stopping or hinder working order of SCADA system.• The Contractor shall specify maximum number of data which shall be achieved by the system without any performance loss. The Contractor shall conduct necessary tests to prove maximum number of data points achieved. The Contractor shall also be responsible to create additional data points necessary for conducting such tests. Any AutoCAD graphics shall be able to be converted to process diagrams and shall be re-loaded and operated after completion of all works and during tests.(e)The Contractor shall hand over to MES the SCADA and application software (as CDs or DVDs) necessary for re-loading software to the system in case of failures The CDs or DVDs shall be provided after making the necessary tests. The operating system ofrouters and work stations shall be of an architecture that provides a multi-tasking operating environment, and SCADA software shall also be multi-tasking. Therefore multiple tasks such as receiving measurement results from devices, displaying these results on computer screen. storing on a computer disk, sensing alarm conditions that may occur based on measurement results, and displaying them to users, generating reports from collected data, and printing them cut, transferring issued commands to Microprocessor controllers/ RTUs/ PLC, that SCADA software is supposed to execute shall be handled simultaneously without one task waiting for another. 22 To configureSCADA software or to change the system configuration, definitions shall be either defined directly by using a keyboard or another interactive tool or mechanisms that allow importing of configuration definitions from a text file created with a text editor. The database configuration shall be provided by means of an interactive program that contains menus or similar approaches and shall be easy to use The database configuration definition program, when required, shall be capable of extracting definitions related to the configuration from information created in text format to use as definitions for configuration The following shall be possible online without interruption or hindering of usual operations: -•Adding an RTU to the SCADA system.•Deleting an RTU from the SCADA system•Changing configuration information related to an existing RTU definition.•Modifying definitions in database containing information about measurement and control points.•Creating screen pictures which offer operators to monitor and control the SCADA system.•Similar configuration changes. 23 (f)SCADA software shall be upgradeable to new versions with an automatic mechanism to be provided by the Contractor. The old version of software shall be overwritten by new version without resulting in a change in any of the definitions created in previous version, nor disturbing the operational logic defined in previous version. Al! text being available on the screen shall be in English language The database shall be configured on-line when the SCADA system shall be in operation. The changes on existing definitions or new definitions related to database shall be made when the data collection n and control functions are being performed. The SCADA Software shall be operated using the database that shall be resident in the memory(g)Data Exchange The control system shall provide a method of real-time data exchange with different application programs like Geo Information System (GIS). relational database, third party spreadsheet packages, report generation and graphical simulation packages.(h) Historical Data Management An historical data management (HDM) system shall be provided for archive, storage and retrieval of operational data comprising field input data, manually-entered data and calculated points Archived historical data shall minimally include averages, minima and maxima for each analogue value compiled over hourly. daily and monthly time periods, with a minimum capacity of 1o00 points. The HDM system shall be capable of selectively increasing the rate of data capture based on events, such as process variable status, discrete inputs, or operator command. Minimum and-maximum data shall include the time and date of occurrence. Gaps in collected data caused by faulty instruments or control system equipment shall not be included in average). minimum and maximum compilations. 24 (j) Report GenerationThe system shall be provided with a report generator utility which shall enable authorised users to create, delete or modify report definitions The report definitions shall allow for retrieval of data from on-line database and farm historical data files and for formatting data for output to printer. The format of each report shall be definable by user to include the definition of static or background data, placement of data base values, number of significant digits of a value, date and time of report and calculated values(k)Graphic Display GenerationThe system shall be provided with an interactive on-screen graphic generation utility which shall allow an authorised user to create new graphic displays and modify or delete existing displays at any work station including those associated with the LCP/ outstations. The generation utility shall include an interactive linkage process allowing user to link symbolic, numeric and bar graph representations and data entry locations to dynamic data base variables. The graphic display system shall be capable of making full use of the VDU resolution in the composition and display of graphic information. Graphic symbols shall be definable by the user for display of static and dynamic data. The user shall be able to as5emble a library of symbols which shall be retrievable into any graphic display. Text and symbols shall be able to be enlarged, shrunk, moved, mirrored or related with reference to a given display. The system shall be able to represent dynamic analogue data on a graphic display as a variable-length, sizeable bar graph, as well as numeric text. 25 (l)DisplaysGeneral all displays, excepting those containing data derived from historical files, shall be completely displayed within two seconds of the operators request. Dynamic data shall be continuously updated while being displayed. All screen displays shall provide following displays which shall be fixed in their locations to normal operations:• Alarm banner window at bottom of the screen display showing last three highestpriority unaccepted alarms. Where the system allows contents of banner to be limited (eg by user name or group) then the selection criteria applied shall be displayed with the banner.• Main display area for user selected displays e.g. mimics, alarm lists, etc.• System dialogue banner window at bottom of the screen shall display relevant system information such as error message and user prompts 26 •A day, date and time indicator shall be able to show local time an alarm bannerarea shall be included on all displays which provide information regarding most resentalarm events. The system shall allow operator to obtain details of most recent alarm event from any operational screen display through direct operation using a maximum oftwo keystrokes or selections. The system shall allow the operator to obtain a print of any display, including graphics through use of a standard system command. Screen displays shall appear identical incorporated form Dynamic data contained on a display shall not change during screen print Such that a snapshot of conditions is portrayed. Each display shall include time of day in hoursminutes and seconds and date in day, month and year format.•A facility shall be provided which allows paging to related displays through the use of ‘page forward or backward keys, or through the use of pick points(m) Suitable size of HT & LT XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts and 1100 Volts grade with stranded aluminium / copper conductor of size as per OEM recommendation and approved design ISI markedincluding cable glands, lugs, jointing kit etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories and necessary earthwork, civil work deemed to be included in quoted rates of the above items.(n)Generic Displays.The system shall produce various generic displays automatically 27 Metering arrangements: (A)Suitable bi-directional metering arrangements with recording facility shall be provided as per the norms of WBSEDCL. The metering arrangements must have feature to measure and record, (i)Parameters of KW, KWh, KVAR, voltage, current, PF and any other metering required to determine efficiency and efficacy of the system. (B) LT 3 Phase 4 Wire Electronic Tri vector Meter with CT ratioshould be as per capacity of SPV plant. (i) Standard: IS 13779:1999 / CBIP 88 (ii) Accuracy: Class 0.5 (ii) The metering arrangement shall have inbuilt Solar PV Plant synchronisation features. (iii) Reference Voltage - 3x240 V (iv) Basic Current (Ib)- 5 A (v) Maximum continuous current (Imax) - 10 A (vi) Rated Frequency (variation) - 50Hz (±5%) 28 (vii) Power consumption:- Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency Current circuit: Less than 1 VA per phase at basic current, reference frequency and reference temperature (viii) Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height (ix) Display in the event of Power Failure: Internal battery back-up for LCD display (x)Communication port: Galvanically isolated Optical Communication port for data transfer through either CMRI or remote device or both is providedwith RS 485 for DLMS protocol (C) CT/PT operatedenergy meter with following features (i) True four quadrant metering (iii) Time and day metering with maximum demand registration and automatic billing (iv) LCD display with announciators for various critical events (v) Scroll lock feature for continuous display of a desired parameter on display (vi) High resolution energy display mode for dial test (vii) DLMS protocol for meter reading, with option to remote reading port. 29 (viii) Advanced event detection features for voltage, current and magnetic influence (ix) Meter reading in absence of mains, using internal battery. (x)Power Manager Device Nano type with 4 inverter support with energy monitoring, zero export control, Load Management having RS-485 communication port, ethernet including RS 485 cable core size 0.5-1.5 Sqmm to establish communication between inverters, SCADA and sensor as per OEM recommendation with and including all connectedaccessoriesdeemed to be included quoted rates.(xi) Digital WIND SPEED SENSOR withminimum 3 cup Anemometer range 0 to 70 Mtr/ Sec distance constant 2.5 Mtrs output TTL Pulses output proportional to wind speed and diameter of cup 50mm with brass housing and stainless stell shaft(xii) WIND DIRECTIONSENSOR with wind vane and sensing vain coupledto linear endlsess potentio meter IP 67, range 0-357degrees, operating temperature -40 to +60 degrees celsiuswith brass housing and stainless stell shaft and aluminium vane complete 30 (xiii) AIR TEMPERATURE SENSOR withRTD sensing element PT100 mounted inside a weather shield duly coated with weather proof reflective white paint , range -40 degree to +60 degree celsius with nylon body housingwith weather shield and brass stem to mount the sensor, includingpower requirment 5 Volt DC complete. (xiv) MODULE TEMPERATURE SENSOR Model PT 1000 measuring range -40 Degreeto + 80 Degree Celcius with suitable ouput as required and directed on site and mounting on RTD encapsulated in suitable housing including connecting cables as required complete.(xv)Tipping Bucket Rain Gauge with Magnet and Red Switch type Sensing, rim diameter 203 mm and collecting are 335 MM SQ, Rain gauge shell made up of FRP bucket and mounting made up of stainless steel SS316 and unlimted capacity,including connecting cables as required complete.(xvi)SOLAR Radition Sensor ARN 8101 with 72 element thermo pile sensor and spectral range 0.3 to 3 Micro Mtrs and sensitivity 20 Micro Volt/ W/M², range 0 to 1500W/SQM & output 0 to 25 milli Volt and operating temp -10 to 70 Degree Celsiusincluding connecting cables as required complete with all fixing arrangment and necessary civil work complete with including all connectedaccessories as per OEM recommendation/Designcomplete: 31 (L)Step up solar transformer (800 volt/11 KV)” - Design,procure,erection, installation, testing and commisioning including connecting to local utility grid :Oil filled Type 3 phase, 50 Hz, ONAN cooling type, vector group of appropriatetype, number of load voltage Ratio: number of Phases / Freq.: 3 Phase / 50 Hz., Sealed type Copper wound Transformer with Off Load Tap Changing Arrangement on HV side in steps of 2.5% , +5% to -10% having cable end boxes on HV side suitable for 3 Crore X 300 Sq. mm. XLPE cable of 11 kV grade on HT side and LV side complete with all accessories like buchholz relay, Oil temperature indication, winding temperature indication and alarm etc preferbly DMCR Protection Relay i/c first filling of filtered dehydrated K Class natural Ester Oil bioTransol (as per IS 16659) and confirming to IS 1180 and losses shall be as energyefficiency Level 3 only & 100% load phase, with an impedence of 6.25% i/c as per specification below complete in all respects as required at site. Design ambient to be considered as 50 Deg C.All the balance parameter like temp rise, Basic insulation level, flux density etc shall be strictly in accordance with IS 1180 Part - 1 only including necessary earth work, PCC plinth foundation etc.Heat Run Test is the mandotary test for each Transformer.Standard: The equipment shall conform to the latest edition of applicable standards as follows. In case of conflict between applicable standards and this specification, this specification shall govern.• IS 2026 Standard for Oil filled Transformer• IS:3639 for Fittings and Accessories• IS:2099 for Bushings > 1000 V• IS:7421 for Bushings < 1000 V• IS:1271 for Electrical Insulation classified by Thermal stability• IEC 62770 Natural Ester Oil• CBIP Guidelines 32 (xvii) CORE : Transformer shall be double wound, core type with low loss, non-ageing, high permeability PRIMEGRADE, CRGO with M4 Grade or Better, perfectly insulated and clamped to minimize noise and vibrations. Followings should be Mandatory for any manufacturer: -(a) Transformer shall be of BOLTLESS core design.(b) Core shall be purchased Directly from Manufacturer or from their accreditedMarketingorganization of Repute & not through any agent. Bidder has to submit manufacturer’s name during bidding having sufficient credential & Core has to be purchased from the approved manufacturer.(c) Stage inspection of the core shall be done at manufacturer’s premises & inspection call shall be given with following Documents: (i) Invoice of the supplier (ii) Mill’s test certificate (iii) Packing list (iv) Bill of landing & Bill of Entry certificate by customs(d) Transformer manufacturer should have in-house core cutting facilities for proper control & monitoring of quality & to avoid mixing of Prime core with Second grade /defective core materials. Transformer Manufacturer should have in-house slitting Machine so that core is cut to width & stacked with minimum air gap thus ensuring Burr level less than 10Microns.(e) Core shall be procured from one of these reputed Manufacturers : Posco / Nippon/ Novex/ Ak Steels.(f) The insulation structure for the core to bolts and core to clamp plates shall be such as to withstand a voltage of 2000V for one minute. 33 (xviii)Tank:Tank should be of corrugated wall construction type. The exterior of tank and other steel surfaces exposed to the weather shall be thoroughly cleaned and have a priming coat of zinc chromate applied. The second coat shall be of an oil and weather-resistant nature, preferably of distinct colour from the prime and finish coats. The final coat shall be of a flossy, oil and weather resisting non-fading paint of specified shade. The interior of the tank shall be cleaned by shot blasting and painting with two coats of heat resistant and oil insoluble paint.Winding:(a) Winding shall be made with 99.9% pure electrolytic grade copper, insulated with thermally upgraded paper (Insulation Class A / Conductor Turn Insulation-Class E).The HV & LV winding should be able withstand thermal and mechanical stress in the event of short circuit.(b)Winding shall be carried in dust free area(c) The completed core and coil assembly shall be dried in vacuum and shall be immediately impregnated with oil after the drying process to ensure elimination of air and moisture within the insulation.Oil type: TransformerTransformer oil shall be as per IS-335:1993. It shall be natural/synthetic ester oil. The material safety Data Sheets (MSDS) for the Transformer oil shall be submitted by the bidder along with the offer Temperature Indicator:One set of winding temperature indicators with necessary current transformer, heating coil and a detector element and one set of oil temperature indicator with maximum reading pointer shall be mounted locally so as to be readable at a standing height from ground level. Each of the above indicators shall be provided with necessary contacts for alarm and trip: (a) Oil Insulation class : K class. It should also exhibit safety against fire hazards 34 (b) Cooling : ONAN(c) Vector Group: to be decided during design.(d) Percentage Impedance (Z%) 6.25 %.(e) Transformer Losses:as per IS 1180 - Level 1(2021)(f) Taps on HV for HV variation : +5 to -10 % in steps of 2.5% each (g) Termination (HV): Cable End box for11 KV cableof suitable size(h) Termination (LV): Cable connection(j) The transformer shall be supplied with following fittings:(k) Lifting lugs and Jack lifting pad support(l) Earthing terminals - to be decided during design. 35 (M)Earthing :The complete system shall include chemical earthing of required quantity for step-up Transformer (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account in case of any dispute decision of Engr in charge will be final and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 36 IMPORTANT NOTE FOR SOLAR POWER PLANT CONTRACT (COST DEEMED TO BE INCLUDED IN QUOTED RATES :-(1) The item specification and details given are for guidance purposes only and are likely to vary with modified / higher specification than that specified in the BoQ based on detailed site survey, solar potential assessment, design approval etc keeping the quantity of Solar inverter (PCU) and Solar Transformer same as in the BoQ. The items as per the finalized and approved design and specification, including make, shall be provided by the contractor without any extra cost to the department. All makes should be as per the latest MNRE approved list of makes and models.2.Cost of preparation of DPR design vetting from NISE/MNRE approved Institute and net billing arrangement (as per WBSEDCL) is deemed to be included in the quoted rate.3.The contractor shall submit complete design of Solar power plant, Schemetic/line drawings, detailed mounting structure array layout drawings alongwith SBC report based on the soil investigation as per OEM recommendation, Single line diagram with and including project reportand connected document shall be submitted by OEM through contractor prior to commencement of the work for approval of Accepting officer and subject to the drawing and designduly vetted by IIT/NIT (for mounting structure only) and vetted by NISE/ SECIfor entire scheme of Solar Power GenerationProject including evacuation and Net Metering arrangement complete before recommendation by GE for approval of the accepting Officer. 37 (i) The scope of works involves engineering, procurement & construction (EPC) of entire Solar Power Plant of capacity 0.8 MWp.4. The entire work shall be executed directly by OEMonly through contractor and contractor has to submit the MoU with OEM (agreement period for 25 years of entire Solar Power Plant Project) prior to commencement of work and same shall be approved byGE. 5. Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain any type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore have to berepaired and made good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes for entire Solar Power Plant Project, exavation, removing, return filing, channel, any type of metal work is deemed to be included in the quoted rate. 38 6.Cost of comprehensive maintenance as per OEM recommendation alongwith cost of spare parts required during 5 years of defect liabilty period after completion of Ph-I is deemed to be included in the quoted rate.7. Bidders attention is drawn to pre-bid conferance with department and also visit the site prior to bidding and other factor required as per OEM recommendation deemed to be included in quoted rates.8. The contractor has to carryout Pre-commissioning test of solar power plant including stepup transformer by CEI/SEI. The necessary tools and plants required for inspection of the plant shall be arranged by the contractor.and costsare inclusive in quoted rates.9. Contractor needs to know the irradiance of the location at the project before quoting. The contractor will design DCR (Make in India) for entire Solar Power Plant according to irradiance of the project location and efficiency of the components to produce the desired peak value as mentioned in the schedule i.e. 800 KW output on 11 KV AC supply and inject to the proposed RMU 11 KV. 10. During the execution of work any type of damage by elephant or monkey manance, contractor is fully responsible for protection of all solar power plant equipments including connected items i.e. PV Module, Inverter etc. No claim will be sought from the department. 39 11. All SCADA related activities viz. cables till SMBS and inverter and the requisite software and hardwarefor control room shall be included in the quoted rate.12. Vegetation Growth should be controlled by use of Deweeding Chemicals deemed to be included in Quoted Rates.13. Adequate Water Storage Facility of capacity 10000 Ltrs PVC Tank 5 Layer (with guarantee of 10 years after physical completion of work) on PCC Platform including suitable foundation for cleaning of PV Modules and suitable water drainage facilitiesfor both (Rain Water and Cleaning Water) from proposed site to existing drainage chamber is deemed to be included in the quoted rate.14. Solar Transformer fed from the Inverter should not be having odd harmonics (certificate needs to be required before physical completion of work).15.The Shutdown duration of Inverter should be monitored and recorded and analyzed. 40 16. The SPV Power Plant will be capable of generating 800 kW AC Output atleast once in a year and the AC Output of the plant will be not less than 90% of initial output by the end of 10 yearsand not less than 80% of the initial output by the end of 25 years.17. The Contractor shall operate and maintain Fire Protection System and safety equipments for the entire Solar Power Plant for 10 Years and cost of the spare is deemed to be included in the quoted rates.18.The firefighting system for the proposed power plant for fire protection shall be consisting of:a) Portable fire extinguishers in the control room for fire caused by electrical short circuitsb) Sand buckets in the control roomc) The installation of Fire Extinguishers should conform to TAC regulations and BIS standards. The fire extinguishers shall be provided for control room housing, PV array installation.19.Solar Components shall not be connected to LAN, WAN, or any Internal Data/OPS nw. 41 20.Sys with Bluetooth, GSM, Wi-Fi, or any Telemetry features should be avoided, unless explicitly cleared monitored.21. Finalization Of Feasibility Report, Design, Engineering, Transportation, Storage, Insurance, Civil Works, Erection, Testing & Commissioning etc., ensuring net-billing as per state net billing policy, quality control of grid connected.22.The Comprehensive Maintenance of SPV Plant would include wear, tear, overhauling, machine breakdown, insurance and replacement of defective modules, Inverters/PCU, spares, consumables & other partsas pe OEM reocmmendation and specification for 5 (Five) years under DLP of Phase-I..23.The Contractor shall arrange technical vetting of the plant during execution by the Cyber/INT officer and training by Unit Technical Pers till defect liability stage of Phase-I. 42 24.a) An energy meter (for net-billing) shall be installed between the solar Grid-tied inverter and the building distribution board to measure gross solar AC energy production (the Solar Generation Meter). The Solar Generation Meter shall be of the same accuracy class as the DISCOM service connection meter or as specified by local regulatory requirements. Separate for two different buildings.b) The bidder must take approval/NOC from the Concerned DISCOM for the connectivity, technical feasibility, and synchronization of SPV plant (if required).c) Contractor shall be provided system software (Cloud) for data hosting of Solar Power Plant with the Government approved agency and also audited by CERT-In (Computer Emergency respose team-India) is deemed to be included in the quoted rates. 25.a) Two sets of Engineering, electrical drawings, and Installation and O&M manuals are to be supplied. Bidders shall provide complete technical datasheets for each equipment giving details of the specifications along with make/makes in their bid along with the basic design of the power plant and power evacuation, synchronization, along with protection equipment is deemed to be included in the quoted rates. 43 b) All test and calibration certificates, wherever applicable.26. The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.27. (a) The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.(b) The contractor will carry out fortnightly, monthly, quarterly and annual maintenance as per Proforma of Appendix here-in-after respectively. In case the contractor fails to carry out the above maintenance following penalty per Solar will be imposed. 44 (i) Not carrying out maintenance fortnightly- Rs 2500.00(ii) Not carrying out maintenance Monthly- Rs 5000.00(iii) Not carrying out maintenance quarterly- Rs 7000.00(iv) Not carrying out maintenance annually - Rs 10000.00(c) The Contractor shall be responsible for ensuring production of 800 kW AC output of electricity at the injection point of RMU atleast once in a year from the SPV plant. In case the output is less than 800 kW AC unit, it will be deemed as under-designed plant. The contractor will be responsible for making good the shortfall by repair / replacement of the SPV Plant free of cost. Delay in this regard will attract monetary penalty to be amounted for the period wef very next day of the completion of Phase-I to the date of completion of rectification / replacement by multiplying the maximum value of units less generated than 800 kW AC for every day with the prevailing rate of electricity tariff of WBSEDCL Rate of electricity in West Bengal is Rs 6.52 per unit as in Sep 2025.(d) Maintenance and supervision shall be done by trained men for the safe operation of Solar’s contractor shall carry out fortnightly servicing including adjustment lubrication, repair of replacement fo parts if necessary. In addition to fortnightly servicing contractor’s senior mechanic of foreman shall carryout the inspection as per maintenance schedule and make necessary entries in the proforma attached here-in-after duly signed by Contractor & Engg-in-Charge as applicable kept in the switch room for this purpose. It will be the responsibility of the contractor to see that the maintenance schedule book is maintained properly by their senior mechanic or foreman. They shall promptly attend and call back & shall not be kept pending for more than 4 hours unless it has the prior approval of the Garrison Engineer. 45 (e) For any repairs/ replacement of Solar the contractor shall always be aware of time factor following are the fixed time (including Sunday/Holiday) for repair/replacement of parts/components/ accessories which shall be adhered to :- (i) Minor repair/ replacement- 4 hours (ii) Major repair/ replacement - 1day(f) The decision of the GE regarding Minor/Major repair shall be final conclusive and binding. In case of failure on the part of the contractor to keep the solar’s in running condition within the stipulated period mentioned in above the contractor is to pay penalty charges as mentioned below subject maximum of 10% of the total contract value and after that measurement will not be considered for the same defective Solar till it is in satisfactory working condition :-(i)Upto 12 hours @ 2000/-(ii) Above 12 Hours and up to 24 hours @ 5000/-.28. RFID Tag scanner of reputed make shall be provided by the contractor is deemed to be included in the quoted rates.29. Existing Room at 33 KV Switch Yard shall be used for SCADA/ Solar equipment/Control Room. 46 30. Surface preparation and laying of light yellow/white coloured interlocking tiles of appropriate thickness under the whole area of PV module array to make a reflecting surface for bifacial Solar PV module alongwith periodical water sprinkling arrangement for cooling of interlocking tiles is deemed to be included in the quoted rates. 31.The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes /LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines is deemed to be included in the quoted rates. Earth resistance shall not be more than 3 Ohms .32. The mounting steel structure shall be as per IS 2061-1992 and galvanizing as per IS 4759 and should withstand WIND Load as per relevant IS Code/NBC.33.Soil Stabliztion testing certificate needs to be required before completion of physical completion of work (Phase-I) so that the performance of the PV Plant is not affected in Highly Soiled areas for minimum 25 years. 47 34. M&O (Phase-II) should be finalize at the planning stage itself. The important point are as under:- (a) The thermal imaging of pv panel should be taken once a year for checking its health including hot spots.(b) The cleaning cycle of panel should be fixed as per the ratio of short circuit current falling below 0.9. The cleaning provision shoul be made available before evacuating the power.(c) The shutdown duration of inverter should be monitored and recorded and analyzed 48 Supplying, Installation, Testing & Commissioning including design, manufacture and testing at works of indoor type , IP 4X ,floor mounted metal clad, 11 KV VCB panel board totally enclosed & fully interlocked, Horizontal drawout, Horizontal isolation type breaker as per IEC-62271-100/200, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, motor charged and manually/electrically closing breaker suitable for use on 11 KV,3 Phase, 50Hz A.C. supply with STC 25 KA for 3 Sec.Internal Arc for AFLR 25kA at rated voltage for 0.1s at individual compartments i.e. Busbar, VCB and cable compartment.complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated and encapsulated copper bus bars of 800 Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 8 NO + 8 NC andequipped with following switch gears and accessories.The panel shall be complete with following switchgear and accessories. The structure of the switchgear must be fabricated using steel sheets coatedwith Alu-Zinc (Aluminium Zinc alloy)/PRINTED CRCA All major sub-components (switchgear, relays, meter & vacuum interrupters) shall be of same make. VCB and vacuum interrupters shall be designed for 100 short circuit operations at full short circuit of 25KA. Breaker shall be roll on floor type/ CASSET TYPE. Separate earthing truck shall be required for each bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth a live. It shall be provided with capacitive voltage divider and complete with audio visual annunciation, one for each panel. Item Continued as 2.01 to 2.04 49 INCOMINGS & Outgoing VCBs :Type : Air insulated VCB, autoreclosing, system voltage :- 11kV + 5%, 50 Hz+ 5%, 3 phase, rated voltage : 12kV, rated current : 800A in 40 ° C ambient, Short time rating for 3 sec : 26.3 kA, Short Circuit Making Current : 65 kA, insulation level (PF rms/ impulse peak) : 35 kA/75kA, System Ground : Solidly Earthed,Duty Cycle : 0 - 0.3 sec - CO - 3 min - CO, Break/ Make time :- Not more than 5 Cycle, Range for Auxiliary voltage for Closing / Tripping / Spring Charging : 85-110%/ 70-110%/85-110%. of rated voltage. The VCB must withstand 10000 mechanical, & 100 at rated short circuit current. The breakers should have auxiliary contact 6 No+ 6 NC, in minimum. The used Breakers will comply with IEC 62271/ IS 13118. Qty. - 3 Nos (1 no Incomer & 1 outgoings)Busbar: Rated Current : 800A @ 40°C ambient, Material : Silver Plated /Tined , High conductivity elecrolytic Copper Bus Bar sleeve :Heat Shrinkable PVC Sleeve with joints having full voltage soft PVC shroude Short time rating for 1sec :26.3kA -1 setCurrent Transformer:Voltage class: As specified in Circuit breaker ; Type: cast resin type, Dual core, Dual Ratio , Barden :10VA; Class insulation : Class E or better . Protection core: 5P10, Metering : 1.0 , Short time rating for 1 sec :26.3kA Ratio :300-150/1-1, 7 setsBus Potential Transformer: Rated Voltage : Primary - 11000 / ✓3 , Sec -110✓3; Type : Cast resin , draw out type, 3- phase , 3-limb complete with HV fuses . Barden : 100VA per phase ; Class of insulation : Class F or Better , Accuracy Class: 1.0;Rated Voltage factor : 1.2 continuous, 1.5 for 30 Secs. PT shouldbe drawnout type and serivce continuously shall be indepandent of Breaker trolly position...1set 50 Relay for Control & Protection: Numerical Type IDMT Relay (50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Additionally, condition monitoring CB wear, condition monitoring CT supervision, disturbance recorder, undervoltage & over voltage protection, trip circuit supervisioncan be measured through the relay. The device shall support webserver/web HMI through which we can monitor and control the relays over a ethernet Lan network. Licenses for theprogramming software shall be provided free of cost.The numerical relay shall have large mimic-based LCD screen display . .The relay shall have 8 Digital inputs and 8 Digital Outputs and one additional watchdog ouput.The device has to aloe controlling of min. six objects (circuit breakers, disconnectors and grounding switches). Controlling has to be done by “select-execute” or “direct control” principle. Controlling has to be possible by: through local HMI, remote communication, via digital input or via function key. Events has to be readable to SCADA systems, front panel or by setting software.The sample rate of the recording has to settable to 32samples/cycle.The devices shall provide storage up to events 2000 based on the resolution.The device shall support following communication protocols: Native IEC 61850 ed1 & ed2, Modbus TCP. The IEC 61850 communication has to support peer to peer communication (GOOSE) if requiredThe IEC 61850 interface must be able to configure through setting software. Also the same setting software has to be able to generate ICD filesThe device shall have KEMA IEC61850 edition 2 certificates - 3 sets. High Speed Master Trip relay VAX31- 3 Set, Ttrip circuit supervision relay-VAJH13-3 set6 Window Annunciation Facia . with ACCEPT, RESET & TEST Push Button - 3 set . Auxillary relay for Transmission faults (VAA33)- - 3 Set 51 Metering: Meters: 1-NosUL&CE Multifunction Digital meter displaying Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.Temperature Monitoring Sensor for the Three Phases of Incomer VCB Panel :Supply, installation, testing & commissioning ofthermal monitoring system to be provided to detect abnormal temperatures due to faulty connections and to prevent equipment B19damage. The switchgear shall have wireless temperature measurement sensors at all critical points:(a) 3 nos. foreach phase at incoming side cable joints The wireless temperature sensors installed on conductors shall be :(i) Installed with direct contact to hot point, to achieve accuracy of +/- 2°C(ii) Self-power (no auxiliary supply, no battery)(a) communicate wirelessly(c) Operate from -25°C to 125 °CThe system shall allow 2 configurable thresholds (pre-alarm and alarm). This system shall have integrated algorithms enabling to anticipate as early as possible an abnormal temperature, before damage occur (strong predictive capacity) and generate alarm through SCADA/monitoring software. Thermal sensor shall beself powered by the network current. Temperature data is sent via Zigbee wireless communication to provide high performance and accurate thermal monitoring. The sensor is secured to the connection point and is in direct contact with the measured point. Smartphones or tablets (with a Zigbee communication dongle) can be used with our Thermal Connect mobile application to scan data locally and can replace the need of periodic infrared scanning. Thermal sensors should comply to following standards:1 EN/IEC 61010,2010 2. UL 61010-12, 20123. ETSI EN 300238, 2012 V1.0.1 4. IEEE 802.15.4, 2013 52 Power Pack shall be with 220Volt AC Input & 24 volt DC continuous output suitable for closing /tripping indication of HT panel boards with 2nos 12Volt 100AH maintenance free batteries, chatging unit for trip system complete with suitable capacity dogital MFM connections with 2.5sq mm FRLS inaulated copper conductor cable etc as required.-4 set.The 11 KV HT Switchboard of 1 panel,shall bewith all accessories, interconnections,internal wiring, labels, space heaters etc. complete as required.3 panels shall be mechanically interlocked in such a way that only one operates at a time and multifunctional digital meters shall be interconnected and programmed in such a way that total consumption will come in one meter summating both of them.Note: 1. Quotated rates shall be inclusive of construction of foundation for the installation of VCB as per OEM drawing.2. The equipment shall be tested by SEI post sucessful installtion and report shall be submitted to this office. 53 Design, Manufacturing, Supply, Installation, Testing and Commissioning of 3 way 12 kV rated Ring Main Unit ofwith Fault Level 21KA 3 sec internal ARC 1 sec for tank and cable box , consisiting of 630A12 kV rated , 2 nos motorized type VCB as incomers & 1 load break switch as outgoings with metering modules along with necessary Earth Switches,battery and battery charger for shunt trip arrangement andMotor and other auxiliary circuit operation, HT CopperBus bar with current density not more than 1.6A/sq. mm as per detailed description as follows: RMU Construction: The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure to ensure the insulation and breaking functions. Sealed for life, the enclosure shall meet the sealed pressure system criterion in accordance with the IEC 62271-1 standard (§ 3.6.5.4): a volume for which no further gas processing is required during its entire expected life”. In addition, manufacturer shall confirm that maximum leakage rate is lower than 0,1 % / year. It shall provide full insulation, making the switchgear insensitive to the environment (temporary flooding, high humidity...), IP67 degrees of protection in accordance with recommendation IEC 60529 § 14.2.7. No SF6 gas handling required at site. Thus assembled, the active parts of the switchgear shall be maintenance-free and the switchboard shall be low-maintenance. The switchgear operating mechanism shall have an IP2X protection and cable chamber shall be IP55, Over all IP protection shall be IP55 . The tank shall be made of at least 2mm unpainted stainless steel. Item Continued as 3.01 to 3.05 54 VCB is the preferred dielectric medium for MV RMUs. Oil filled switchgear will not be considered. RMU shall be in accordance with IEC 60376.Any accidental overpressure inside the sealed chamber will be limited by the opening of a pressure limiting device in the lower part of the enclosure. Gas will be released to the rear or the bottom of the switchboard away from the operator and internal arc tested for both cable and tank for 21KA 1sec AFLR with test conducted with minimum 3 functions TankNumber of mechanical operations of Circuit breaker 2000 O/C , Number of electrical operations at full loop current for LBS: 100 O/C , Number of electrical operations at full loop current for CB: 2000 O/C,. Manufacturer shall provide type test report to prove compliance with IEC 62271-200 Annex A, Internal arc classification class AFL with 21kA 1s for the enclosure. Make of the RMU, vaccum intrtupter , relay & meter shall be of same OEM. All the test certificate shall be in the name of the OEM only . If there is any name change / acquisition by other OEM happened for the RMU then test cerificates shall contain the new OEM name only.HT System : 3 phase -3 wire , HT Fault level21 kA, Power System earthing - solindly earthed at up stream source, HT Copper Bus with Short Time Curent rating 21 kA for 1 Sec ( 3Sec), Continuous current rating at least 630 A. tank and cable chamberof RMU must be IAC rated for 21 kA for 1 Sec AFLR. Design ambient to be considered as 40 Deg C.HT Circuit Breaker :(i) There shall be 1nos.load break switches as incomings and 2 nos 12 kV rated VCBas outgoing ( total 3 nos.) . The circuit breakers shall be fixed type. All of the switchgear shall be capable of withstanding this current without any damage being caused, in accordance with the recommendations IEC 62271-1 and IEC 62271-200.Loss of service continuity class: LSC2(ii) The Circuit Breaker must be rated for 12 kV ( nominal Voltage), 28 kV/75 kVp ,3 Phase, 50 Hz, Short Circuit Fault Level of 21 kA for 3 sec. 55 (iii) No. Of Close Coils - 01 no. operable at 24 V DC (85% - 110%)/ Spring Assited Closing, No. of Trip Coils - 01 nos. ,operabale at 24 V DC ( 70% - 110%) for shunt trip.(iv) Provision for supervision of the shunt Trip Circuits for the Trip Coils to be provided. (v)Switchgear classification: PM class(vi) Loss of service continuity class: LSC2(vii) Duty Cycle : O – 3min – CO – 3min – CO, Vacuum Circuit breaker shall be of M1, E2, C1 duty and capable for minimum 50 short circuit breaking operation at full short circuit level.(viii) STC rating 21 kA for 3 Sec (for Vacuum Interrupter).(ix)Vacuum Interruptor must be hermetically sealed and must comply IEC 60056 ( along with latest amendments). Vaccum interrupter shall be of same make as RMU(x)Circuit Breaker to be equipped with Suitable tripping arrangement with push button, Mechanical counter to assess the total number of operations of the breaker, Mechanical ON / OFF indicator, Auxiliary switches, Auxiliary Contacts( at least 2 NO + 2 NC of Class 2 category), Emergency trip push button.(xi) The Operating mechanism shall be spring charged motor operated/ spring assisted as per OEM type tested design type with Spring Charge Universal motor operable on 24 V DC / 230 V AC.(xii)Suitable monitoring of Bircuit Breaker status ( ON, OFF, Trip, CB Spring charged if applicable), Trip Circuit Healthy / Unhealthy, DC healthy/unhealthyto be provided using (xiii) Voltage Presence Indicator shall be provided against each HT circuit ( against each VCB) on line side for knowing the presence of line enerzisation status.(xiv)Number of Mechanical operations at full rated current for breaker: 2000 O/C 56 HT CT /PT : Load Break Switch - 11 KV, 630A, 21KA for 3sec Motorized Load break switch; with built in line side manual earth switch. Earthing should be completed within 2 operations only(i.e 1. Main switch - OFF, 2. Earth switch - ON). LBS shall have 3 positions, open or disconnected, closed and earthed, and will be constructed in such a way that interlocking prevents unauthorized operations. For earth switch, manual opening and closing will be driven by a fast-acting /snap action mechanism, independent of operator action. LBS and earth switch shall have a min of 1000 (M1) mechanical operations ,and 5 nos closing operations at rated SC current. LBS should have 100 electrical operations at rated current. LBS & Earth Switch should have separate apertures for operation.i) One set of 03 nos. ( for 3 phases) dual core Cast Resin CTs for Eachincomer VCBcomplying with IEC:60185 & IS 2705 ( along with latest amendments) , Core -1 - 400-200/1 A , 2.5 VA, Cl 0.5 for metering ; Core-2 - 400-200/1 A, 2.5 VA , 5P10 for Protection.ii) 01 no. of 03 phase Dual Core PT forHT bus ( 11 kV)with protection HRC fuseCore 1- 11kV /√3 / 110V/√3, Cl 0.5s, 50VACore 2- 11kV /√3 / 110V/3, Cl 3P, 50VA(iii) Multifunction Meter:2 Nos. 3 phaseDigital Multifunction Meter6400NGwith Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.for each VCB panel ( 96 mm x 96 mm) , Flush mounted, Class 1 conforming to IEC 62053-22 ( along with latest amendments). 57 Protection Relay: (i) 2 Nos. of Numerical Type Self-powered IDMT Relay(50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Relay should communicate on Modbus RS-485.(ii) Each VCB must have separate Anti Pumping Relay / Antipumping feature through motorization circuit.Fault Passageindicator: The FPI shall facilitate quick detection of faulty section of line. The fault indication may be on the basis of monitoring fault current flow through the device. The FPI should be self-powered and should have internal lithium battery for external indication and setting of FPI in the absence of current.The FPIs shall include: Fault detection - Phase to phase and Phase to earth faults.One potential- free output contacts for hardwiring to RTUs. On this basis, the SCADA/DMS will be able to monitor phase / earth fault condition.Local fault indications - LCD display on FPI front panel along with LED indication on front panel of RMU enclosure.Multiple reset option : End of time delay (Adjustable from 2 to 16 Hrs)Remote reset (Via potential free input contact of FPI)Manual reset (Reset button on front panel of FPI)Automatic reset on current restoration.The characteristics of the FPIs shall include: Phase fault thresholds configurable from at least 100 to 800 A,Earth fault thresholds configurable from at least 20 to 200 AMultiple number of steps for adjusting phase and earth fault thresholds. Fault current duration range configurable from at least 40 ms to 100 ms in 20 ms steps and further 100 ms to 300 ms in 50 ms steps. Variations with respect to these characteristics may be acceptable as long as they prove applicable and provide the same or better flexibility. 58 EARTHING : The cables shall be earthed by an earthing switch with short-circuit making capacity, in compliance with IEC 62271-102 standard. The earthing switch can only be operated when the switch is open. The switch and earthing switch operating mechanism shall have a mechanical endurance of at least 1000 operations. Integrated line side Earth switches shall be provided in each HT Circuit. ( against each VCB)RMU Bushing & Cable Termination: It is preferable to have all bushings accessible from the front of the RMU. Bushings along the sides or the rear of the RMU are not acceptable.For each cable compartment, the bushing shall be at the same height in order to facilitate a possible reversal of the cables. The bushing should be conveniently located for working with cables specified and allow for the termination of these cables: - 630 A M16 bolted connectors for switch-disconnectors and vacuum circuit breakers functions.The profiles of the cable connection bushings shall be in compliance with IEC-60137 standard. Cable clamps:A cable clamp arrangement must be provided for all network cables terminated on the RMU.Provision for Cable Entry: There shall be suitable provsion for Cable entry from bottom through 3 mm thick CRCA steel thick detachable gland plate along with provision for termination of 2 runs of 3 c X 300 Sq mm 11 kV (E ) , XLPE insulated Aluminium Cables (for HT side) and at LT side runs of cables matching with outgoing MCCB current rating.Note: (i) Quotated rates shall be inclusive of foundation for the installation of VCB as per OEM drawing.(ii) The equipment shall be tested by SEIaftersuccessful installtion and report shall be submitted to this office and cost deemed to inclusive in qoated rates 59 M&L for water proof, 3 core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade including PVC conduits properly fixed on steel poles using GI wire for electrical connection of street light fittings, complete all as specified and directed. 60 Supply and fixing junction box having protection dust proof, acid resistant, shock proof, fire retardent self extinguisher for outside installation with knockout entry for cable of size 10 - 25 sqmm andminimum size 295x195x95 mm with terminals, with and includingbrackets for street light pole mounting andone 6A MCB SP complete all as specified and directed. 61 M&L for Advanceencapsulated compound based Chemical earthing CPRI tesed maintenance free , pipein -pipe technology upgraded(Zinc & Alloy coated). , Zinc & Alloy coated (80 -100) microns with pure zinc (99.9%) & Alloy coating (200-250) microns. Earthing system conforming IS 3034. The outer and inner pipe should be 76.2 mm and 41.9 mm dia respectively of3 mtrs long zinc coated with additional special alloy coating 300 mm on top side for additional protection of the terminal . The annular space between the pipes to be filled up with Compactfill (CF) (Crystalline Conductive) mixture which should bemachine pressed in the pipes not disintegrate or collapse when outer pipe corrodes . The inner pipe should be extended with terminals for connectivity.The job includes digging the pitsin any type of hard densesoilof min size 1000 X 1000 X 3050 mm depth taking out excavated soil, lowering/ placing thethe pipe in pipe earth electrode in pit in center ,filling of pure conductolite back filling compound (BFC Conductolite) having excellent moisture retaining capacity in 300 mm around the electrode(minimum 4 bags of 25 KG per pit per unit) or more qty of backfillcompoundas required to fill around the the elctrode in 300 mmin circumfrance of electrode . Contractor has to fill the remaining portion of pit withlow resistivity soil (agriculture soil) free from stones etcs, to be bring from out side defence landas the soil resistivity ofStn is very high and mixed with min 3 Bags of 50 Kg each of Bantonide clay. The BFC should be eco friendly it should not contain envernmently hazardous material/metal having ROHS certification from NABL accredited lab.The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals. The material of earth electrodeshould have good electrical conductivity & anti corrosion property in wide range of soil conditions. The job also include M & L for in PCC(1:3:6) typeC-1 around the FRP cover for support and foundation and colouring the PCC work withdesired colour.completeall as specified and directed. Item Continued as 6.01 62 Note : (i) Design of earth electrode should be of pipein-pipetechnology .(ii) Contractor have to submit literature of earth electrode and get the make approved of GE before procurement.(iii) The earth electrode shall be CPRI tested to withstand short current test for 60kA rms for 1.0 second and 150kA for peak current.(iv) Contarctor has to fill pure back fill compound conductolite all around the earth electrodein 300 mm bore up to full depth of bore.(v) Contractor shall refill the pit with low resistivity soil (agriculature soil ) free fron stone etc and mixed with 06 bags of Bentonite of 25 Kg each to achive the low resistance values. (vi) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection. This Earthing System used for VCB and RMU only. For Solar Power Plant Earthing System is already deemed to be included in quoted rates.(vii) Necessary cost of repair to plinth protection and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 6 x Bags of bentonidedeemed to be included in the item rate.(viii) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work. 63 SAFETY EQUIPMENTSSupply and fixing Rubber hand gloves suitable for 11 KVas per OEM recommendationcomplete all as specified and directed. 64 S&F for glass framed Shock treatment chart both in Hindi & Englishand connected accessoriescomplete all as specified and directed. 65 S&F for dry powder chemical type 4.5 kg fire extinguiser with clamps and connectedaccessories ISI Marked complete all as specified and directed. 66 S&F for single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. as required as per OEM recommendationcomplete all as specified and directed. 67 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. 68 Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, manholes, laying of UG cables/pipes etc. not exceeding 10 Sq.m on plan and getting out in soft/loose or any type of soil complete all as specified and directed. 69 Removing excavated material (soils) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. 70 Returning filling in, soft/looseor any type of soil including spreading leveling watering and ramming complete all as specified and directed. 71 Excavation in post holes (or similar holes) in soft/loose soil each n.exc 0.50 cum, getting out,returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface all as specified & as directed. 72 M&L for RCC M-20, design mix (using 20mm graded crushed stone aggregate), including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 73 M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plugs, bolts, nuts & screws as specified type 410 SP-31, 9.0 meter longinclusive of two coats of aluminium paint over one primer coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified and directed.NOTE : (a) The poles shall confirm to IS - 2713 & each component pipe shall be ISI Marked & confirm to IS - 1161. (b) Necessary earthwork, PCC etc. shall be measured & paid separately under relevant items of work. 74 S & F LED Street lights nominal power 90 Watt, LED of Make Osram; Bridgelux ; Philips; Nicha; Cree; Samsung, LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hourswith IK10 and L70 on including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.(i) If connection.cable from pole Juction box to street light and street light bracket up to 2 mtrs be included and measured in unit rate item, Beyond 2 mtrs of length to be paid seperately under respective items.(ii)At location where street lights/flood light are connected through overhead conductor, connection cable from light fitting to overhead conductor is deemed to be incl in the item rate. (iii) All LED street light/flood lights shall be properly connected with earth dolly provided with fittings and steel poles earth bolt.(iv)All LED lights have replacement warranty of 5 years from the date of completion of the contract accordingly condition 46 of GCC (IAFW-2249) shall be amended to extent mention above. Contractor has to submittwarranty certificate from manufacturer . Payment of light fitting will be released after receipt of 3 year replacement warranty certificate from manufacturer.(v) The LED lights will replaced bythe contractor free of cost in the case of manufacturing defects and Failure due to electrical impact if not connected properly with earth. Hence it is contractor responsibility to connect the light fitting earth wire and shall be grounded properly.(vi) The contractor shall submit the surge protection certificate and Type test certificate LM 79, LM 80 for luminaries from LED manufactutre. 75 M&L for Cement concrete (1:4:8) type D2, (Using 40mm graded crushed stone aggregate) as in foundations of poles and stay, filling and mass concrete complete all as specified and directed. 76 M&L for plain cement concrete (1:3:6), type-C2 (40mm graded crushed stone aggregate) as in foundation, filling and mass-concrete, coping etc for pole foundationwith and including necessary formwork complete all as specified and directed. 77 M&L PCC (1:2:4) type B2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete and copingwith and including necessary formwork complete all as specified and directed. 78 Material & labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick burried directly in ground (Earth pit not less than 4 mtr deep below ground level) with top edge of the plate not less than 3.25 mtrbelow ground level connected to copper strip 20 x 3.15 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation for earth pitin hard dense soil, rocky / disintergate rock, filling charcoal and salt around the plate in layers , filling the pit with low resistivity agriculture soil free from stones, to be bring from out side defence land and mixed with Bentonite , (4 bags of 25 Kg each ), construction ofinspection pit ( earth pit chamber) of brick work of size 600 x 600 x 600 mmwith PCC copping of 1 :1.5: 3, 12.5 mm aggregate A1 with MS sheet 2.8 mm plate cover on frame ofangle iron of size 40 x 40 x 5 mm with , wire mess, funnel, test point, 40 mm dia GI protection pipelightgrade and20 mm GI peforated pipefor wateringetc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately Item Continued as 22.01 79 NOTE :-(i) Contractor shall uselow reisistivity fresh agriculture soil , mixed with 4 x Bags of bentoniteclay of 25 Kg each for refillingthe pit to achive the desired resistance.(ii) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection(iii) Necessary cost of repair to plinth protection as per existing specification and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 3 x Bags of bentonitedeemed to be included in the item rate.(iv) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work.(v) Contractor has to submit test report of earthing after completing the earthing.(vi) Bentonite clay should be Conf to IS 6186: 1986.(vii) The cost ofCopper strip of size 20X3.15 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately.(viii). All the joints in copper strip and connection with Earth Plate to be welded through brazing and in addition by proving brass nut bolt and washer are deemed to be included in the unit rate. (ix) Cost of brazing / welding and nut bolts are deemed to be included in the unit rate. (x) Cost includes removal of excavated soil upto a distance of 100 mtrs. 80 Supply and fixing copper strip of size 20 x 3.15mm as earth continuity conductor or main earthing lead fixed on V typeporcelain insulator, 4 BM, heavy duty ( ceramic bus bar supportinsulator off whitecolour ofsuitable for mounting strip of 20 mm wide x 3.15 min thick) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3.15 mm copper strip brazingto each joints and connected with by providingbrassnut boltsand washer including test point all as specified and directed by Engr in Charge. Note : Insulators shall be provided on every 50 cm. (Minimum 2 x insulators to be provided in every 1 x metre of strip and rate of the same deemed to included in quoated rates) 81 M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as specified and directed. 82 Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and as directed. 83 M&L for GI pipe 100 mm bore, light grade with all fittings and fixtures (ISI Marked), laid in trenches, under road or fixing on wall/ pole /crossing drain /nallah etc. of bore complete all as specified and directed. 84 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 85 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 86 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 87 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 88 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 32 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 89 S&F for 63mm (OD) PP-R Gate valves (brass insert)and connected acessories complete all as specified and as directed. 90 S&F for 32mm (OD) PP-R Gate valves (brass insert) nd connected acessories complete all as specified and as directed. 91 M&L for hard core of gauge not exceeding 63mm with broken stone or boulders, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed. 92 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. 93 S&F for RCC pipes of 600 mm dia, NP-2 laid and jointed complete with collars complete all as specified and directed. 94 S&F for 250mm bore Flue pipes of mild steel sheet, black, in suitable lengths as approved by GE and fixed to walls complete all as specified and directed. 95 M&L for Brickwork with fly ash bricks (modular bricks ), straight or curved on plan exc 6m mean radius, built in cement mortar(1:6) complete all as specified and directed. 96 Material and labour for plastering 15 mm thick (in two coats of 10 mm and 5 mm thick) on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound will be deemed to included in qoated rates. 97 M&L for applying three coats of white wash on newly plastered wall surfaces including preparation of surface complete all as specified and directed. 98 S & F hot rolled low tensile structural steel of grade E165 as per IS 15911: 2010 as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. Wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar works complete all as specified and as directed. 99 S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge. 100 S&F flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 S&F MS screw bolt (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc. 5 cm and n. exc 10 cm long, diameter of neck 5 to 10 mm complete all as specified and directed. 102 Supply and fixinggalvanized steel chain link fence fabric of mesh size as approved , made out of 4 mm nominal dia of mesh wireconforming to IS 2712-2003 and having zinc coating of type heavy as laid down in IS-4826 including line wires/ binding complete all as specified and as directed(A Board of Officers under the orders of GE shall be convened to ascertain the weight per square metre of galvanized steel wire chain link fencing brought at site by the contractor against each lot of materials). 103 S&F 10mm round bars Fe-410-W (Gde-250) quality-A or Fe-290-(Gde-E-165) as in stiffner to hold the chain link fencing fixed with angle iron post inclucinding necessary welding and fixing arrangement at ends complete all as specified and directed . 104 S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steelpins, etc. complete all as specified and directed . 105 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 106 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface not exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 107 Materials and Labour for reinforced cement concrete M-20design mixin columns; pillars; piers; posts; struts etc,complete all as specified and directed. 108 S&F for Mild steel TMT bars 10mm dia and over, conforming to Fe 500 D, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 109 S & F for mild steel TMT bars 6 to 8 mm dia, conforming to Fe 500 D cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, stirup,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 110 M&L for construction of valve chamber with MS sheet cover 3mm thick with angle iron) frame of size 50 x 50 x 6mm and locking arrangements including painting one coat of primer followed by two coats of black sysnthetic paint including excvation and earth work in any type of soil,PCC (1:4:8) type D2 in foundation ,PCC benching 1:2;4 type B-1 ,PCC (1:5:8) block masonry 20 cm thick in cement mortor (1:6),10 mm thick plastering in CM 1:4 ,PCC bed in (1:3:6) and coping 50mm hick in cement concrete 1:2:4 type B1 using 20mm stone aggregate including necessary formwork,paintin one coat of red oxide and two coats of bituminious black paint on all steel surfaces as specified and as directed of sizes 800mm x 800mm x800mm (internnal dimensions) complete all as specified and as directed. 111 Sch A Part-II (Phase-II) 112 Providing Services for Manning and Operation of Solar Power Plant 0.8 MWp near 33 KV receiving stationat Sevoke Mil Station for FIRST YEAR after completion of Ph-I of the subject work with oneskilledcategory Electricianhaving certificate of Surya Mitra from NISE) for twoshifts of 8 hour, one helper (semi-skilled category) in two shift of 8 hrs eachcontinuous operation (including Sunday/Holiday) to maintain sub station in/out side Panels, Invertor, DC junction box, VCB as specified, including daily and weekly check up including cleaning of PV modules complete with suitable cleaning cloths etc , upkeeping the installation operational and in health condition, having own conveyance and communication system like mobile etc. complete, for Solar Power Plant with all minor consumable and expendable items and labour and tools for smooth and efficient operation complete all as specified and directed by Engineer-in-Charge. Make of spare parts / equipments of the Solar Power Plant :- Same as installed in the preceding phase of the work.Repair or replacement ofdefective components or spare parts will be carried out free of cost under DLP and comprehensive Maintenance as per OEM recommendation up to DLP period included in BOQ item No. 1.00. The Contractor may submit his claim for every months on pro-rata basis subject to condition 64 of IAFW-2249 (General Conditions of Contracts)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 17,92,949.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. Item Continued as 56.02 to 56.06 113 NOTES :- In addition to and Manning, Operation and Maintenance of Solar Power Plant, the following works will also be carried out by deputing addl manpower where required, to the entire satisfaction of Engr-in-Charge.(a) Minor repairs and preventive maintenance required to ensure serviceability and efficiency of complete MRS complex including supply of HT 11 KV fuse wire of proper sizeand minor spares such as nut, bolts, spring, lock nut of VCB/OCB as per sample, broom, duster, grass cutting tools, phawara, pick axes for cleaning/grass cutting of complete at Sub Stn Complex. 114 (b) Record of activities such as voltage / current / PF / Energy consumed / temp of transformers, break downs, day to day maintenance of Solar PV Plant etc.(c) The contractor shall ensure that all safety precautions are strictly exercised by the staff employed by him.Adherance to IE rules and statutory rules in vogue must be ensured.The contractor shall be fully responsible for any mishap that occurs due to any fault of the employee or due to non adherance of safety norms.(d) Record of activities such as attendance register, duty roster, pay distribution register of the whole staff employed by the contractor.(e) The electrician staff employed by the contractor shall be ITI holder with four years experience. 115 (g) Security lights within the complex will be operate by the tenderer. (h) The under mentioned tool kitwill be provided at site with person on duty :-(i) Electrician tool kit such as screw driver set, tester, test lamp, cutting plier, insulation tape, fuse wire of required size. (ii) Tongue tester(iii) HT megger(iv) First aid box (v) Shock treatment chart duly framed(vi) 33 and 11 KV Hand gloves(vii) 33 KV discharge rod withcopper chain(viii)) Helmet -02 nos(ix) Suitable Footwear - 02 nos(x) Cotton protective clothing with long sleeves duly embossed with GE Sevoke as directed. The tenderersquoted rates shall be deemed to be include the cost of all above provisions and nothing extra will be paid on any account. 116 (xi) The Bidders shall abide by the latest Labour rules and minimum wages Act. Wagespaid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. (xii) The Bidders is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess et., as applicable and shall be paid to the workmen as per existing Labour rules/ Acts/ regulations and rate quoted shall be deemed to be included for the same.(xiii) Dress Code : The bidders shall provide the workmen with Dark Blue Colour uniform {formal pant & T-shirt} with labels showing/ printed i.e. Name of the firm and designation on front and on the back of the T-shirt along with protective clothing, Industrial safety shoes, protective gears like helmet, safety belt etc..(xiv) Supervision and attending of all incoming & outgoing Solar Power Plant equipment metering equipments & monitoring to loads & other parameters of incomming & outgoing feeders & maintaining log sheet and attendance sheet. 117 INSURANCE: The Bidders shall also insure the workmen employed on the job.The Bidders shall be responsible for all Accidents/Injuries happening to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward incident or non-adherence to safety and IE regulations or fault in maintaining of internal electric supply system or on account of any mishandling/ wrong operation/ lack of knowledge of safety precautions or on account of any circumstances beyond his/ their control, the bidders shall be solely responsible for settling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by Labour commissioner/court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations. 118 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for SECOND YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 18,75,076.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 119 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for THIRD YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 19,61,175.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 120 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FOURTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 20,51,671.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 121 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FIFTHYEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 21,46,848.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 122 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for SIXTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 22,46,564.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 123 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Seventh YEAR after completion of Ph-I.NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 23,51,386.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 124 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but forEight YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 24,61,315.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 125 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Ninth YEAR after completion of Ph-I.NOTE :-(a)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 25,76,917.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 126 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for TENTH YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 27,03,441.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 127 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIRST YEAR after expiry of DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum andcost of item priced upto ₹500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost. Repairs of minor components any other major components are also in the scope and cost of labour for minor / major components is deemed to be included in the quoted rate for this item.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 128 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor SECOND YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted costrepairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 129 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor THIRD YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 130 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor FORTH YEAR after DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 131 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIFTH YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM. (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d) Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 132 Prime Cost Sum. The prime cost to be used as directed by the Accepting Officer vide Condition 1 (v) and 5 of IAFW-2249 (General Condition of Contracts) forming part of the tender documents.(a) Provide a prime cost of Rs.3,00,000.00 forsupply only of spare parts required for comprehensive maintenance after expiry of DLP of Phase-I, through a BOO convened by the CWE. The spares shall procured directly from the OEMs or their aurhorised distributor/dealer as approved by GE.(b) Bidders/Contractors quoted amount shall be inclusive of his overhead and profit and including all taxes and insert amount to cover all. The Bidders/Contractors is to quote lump sum amount under Column 6 covering all the aspects mentioned here in before, representing (%) percentage under Column 9, Above/Below (+ or - denomination) the Prime Cost Sum inserted by MES under Column 5. However, the quoted amount under Column 6 shall not exceed 15% (Fifteen Percentage) of Prime Cost Sum inserted by MES under Column 5. In case, the Bidders/Contractors quoted amount is in excess of 15% of the estimated amount, the same shall be restricted to 15% (Fifteen Percentage) and the amount quoted shall be corrected accordingly to work out the contract sum. Item Continued as 70.01 133 NOTE:-Prime Cost Sum shall be governed in terms of condition 1 (v) and 5 of IAFW-2249 (General Condition of Contract) and to be regularized through Deviation Order. The following procedure shall be adopted to execute the Prime Cost Sum :-(a) Step –I Service Engineer of OEM along with site executive shall visit every month for Preventive and corrective maintenance on all the Solar Power Plant as specified in BOQ herein before, and undertake routine comprehensive maintenance and identify the list of damage / defective spare parts in Solar Power Plant. Service Engineer have to submit report to concerned Engr-in Charge and BOO before undertaking replacement/ repairs, except in case of emergency.(b) Step –II Subsequently BOO will verify the same and submit the finding to the CWE after assembly of board in terms of CA Provision for concurrence.(c) Step –III After concurrence of BOO, the Engr-in-Charge will direct the contractor and the service provider to replace the unserviceable spare parts.(d) Step –IV Serviceability certificate of Solar Power Plant duly signed by the Service Engineer, BOO findings, GST enabled purchase voucher for the replaced spare parts alongwith draft DO details shall be submitted to the GE for placing of DO’s. The advance on account shall be accompanied alongwith the said DO’s for payment.
Contract Date: Mar 17, 2026 Contract Value : 6.86 Crore
Statutory Bodies & Commissions/Committees No of Bidders 6
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : 60.00 Lakh
Government Departments No of Bidders 4
Contract Date: Feb 12, 2026 Contract Value : 1.09 Crore
Statutory Bodies & Commissions/Committees No of Bidders 2
West Bengal View Result →
23.
Educational and Research Institute #9401915 Technical Bid
Supply And Installation Of Electronic Consumables Supply And Installation Of Electronic Consumables For The Department Of Design Iit Guwahati , Electronic Consumables , Arduino Uno (Original Arduino Uno Rev3) , Arduino Nano R (Original Arduino Nano) , Arduino Nano Iot (Original Arduino Nano 33 Iot) , Arduino Nano Esp (Arduino Nano Esp32-S3 Without Headers) , Arduino Nano Ble (Original Arduino Nano 33 Ble Board (Without Header)) , Arduino Mini (Arduino Pro Mini 328 3.3V/8 Mhz) , Arduino Mega (Original Arduino Mega 2560 Atmega2560 Mcu Rev3) , Arduino Giga R Wifi (Original Arduino Giga R1 Wifi) , Raspberry Pi (Raspberry Pi 4 Model B With 8Gb Ram (Latest & Original)) , Raspberry Pi (Raspberry Pi 5 Model With 8Gb Ram) , Raspberry Pi Power Adapter (Raspberry Pi 4 Usb-C Official Power Supply) , Raspberry Pi Heatsink (Black Aluminum Heat Sink Case With Double Fans For Raspberry Pi 4 Model B) , Raspberry Pi Heatsink (Official Raspberry Pi 5 Active Cooler) , Raspberry Pi Keyboard (Official Raspberry Pi Keyboard Red & White) , Raspberry Pi Mouse (Official Raspberry Pi Mouse Red & White) , Raspberry Pi Display (2.8 Inch 480 X 640 Dpi Ips Capacitive Touch Screen Lcd For Raspberry Pi) , Raspberry Pi Display (3.5Inch Resistive Touch Display (C) For Raspberry Pi, 480X320, 125Mhz High- Speed Sp) , Raspberry Pi Display (7? Official Raspberry Pi Display With Capacitive Touchscreen) , Raspberry Pi Display Case (Pi 4 Model B Touchscreen 7 Inch Display Case) , Nvedia Jatson Nano (Nvidia Jetson Nano 4Gb Developer Kit) , Jetson Nano Cooler (52Pi Low-Profile Ice Tower Fan For Jetson Nano) , Tft Diasplay Inch (2.4 Inch Spi Interface 240×320 Touch Screen Tft Colour Display Module) , Lcd Display Inch (1.69Inch Lcd Display Module, 240×280 Resolution, Spi Interface, Ips, 262K Colors) , Lcd Display Inch (2.4 Inch St7789 Tn Lcd Touch Display Panel) , Lcd Display Round (Rp2040 Mcu Board, With 1.28Inch Round Lcd) , Seven Segment Led Display Digit (4 Digits 7 Segment Led Display Module With Clock For Arduino) , Seven Segment Display (0.56 Inch Red 1 Digit 7 Segment Led Display 10Pin) , Usb To Ttl (Ch340g Usb To Ttl(Serial) Converter For Arduino Nano Raspberry Pi) , Bread Board (840 Points Solderless Breadboard) , Vero Board (General Purpose Pcb - 6X4 Inches) , Fan (24V Dc Blower Cooling Fan) , Fan (12V 5010 Cooling Fan For 3D Printer) , Fan (5V 4010 Blue Led Cooling Fan 40 X 40 X10mm) , Water Pump (55W Submersible Water Pump, Pure Copper Winding) , Water Pump (5 W Submersible Aquarium Water Pump) , Water Pump (12V 3M 240L/H Brushless Submersible Water Pump) , Water Pump (3-6V Dcsubmersible Mini Water Pump) , Water Pump (6-12V Dc Diaphragm Based Mini Aquarium Water Pump) , Water Pump (Dc5v Brushless Submersible Water Pump With Usb Power Input) , Air Pump (Kamoer 12V 12W 8000Ml/Min Hlvp8-Kk Diaphram Air Vaccum Pump) , Air Pump (12.0V Dc Mini Air Pump) , Air Pump (Silent And Adjustable Oxygen Pump) , Air Pump (Venus Aqua Aco-003 Air Pump) , Air Pump (Venus Aqua Aco-006 Aquarium Air Pump) , Transformer Step Down (0-24 24V 5A Step Down Transformer) , Transformer Step Down (0-12 12V 5A Step Down Transformer) , Transformer Step Down (0-6 6V 3A Step Down Transformer) , Transformer Step Down (12-0-12 Stepdown Transformer 1A) , Power Diode (By399 Fast / Ultrafast Power Diode) , Power Diode (10A 1000V Silicon Rectifier Diode) , Buck Converter (Buck Converter Power Transformer Supply Dc36v 24V 12V 9V To 5V 3A For Hub) , Fuse (250Ma 250V Glass Fuse - 5X20mm) , Fuse (250Ma 250V Glass Fuse - 6X30mm) , Variable Resistor (50 Ohm Variable Resistor - Trimpot) , Variable Resistor (500 Ohm Variable Resistor - Trimpot) , Variable Resistor (1K Ohm Variable Resistor - Trimpot) , Variable Resistor (10K Ohm Variable Resistor - Trimpot) , Variable Resistor (100K Ohm Variable Resistor - Trimpot) , Variable Resistor (200K Ohm Variable Resistor - Trimpot) , Variable Resistor (500K Ohm Variable Resistor - Trimpot) , Variable Resistor (1M Ohm Variable Resistor - Trimpot) , Lm (Fixed Linear Voltage Regulator, 7805, 10V To 35V In, 5V And 1.5A Out) , Ceramic Heater (12V 40W Ceramic Cartridge Heater) , Switch (1 Pin Flat Dial Switch 2.54Mm) , Switch (2 Way Slide Switch 2.54Mm Pitch - Pack Of 5) , Switch (5-Pin Flat Dial Switch 2.54Mm) , Switch (10 Pin Flat Dial Switch 2.54Mm) , Switch (12-Pin Flat Dial Switch 2.54Mm) , Switch (Dc5v-24V 12V 5A Pir Switch Infrared Motion Detector Sensor) , Switch (Dc 12V 1 Channel Relay Module Infrared Ir Remote Switch Control) , Switch (6X6x4.3Mm Tactile 4 Pin Push Button Switch - 5 Pieces Pack) , Switch (4X5 Matrix Array 20 Key Membrane Switch Keypad Keyboard For Arduino) , Switch (Slide Switch Sk-01) , Switch (Limit Switch-Wk1-2006) , Smps (12V 17A - 200W Ac/Dc Enclosed Switching Single Output Power Supply) , Solenoid Actuator (Dc12v 0.3N 10Mm Pull Type Solenoid Electromagnet) , Solenoid Actuator (Fa0520f 12V Dc 2-Position 3-Way Small Mini Electric Solenoid Valve For Air / Gas) , Laser High Power (High Power Laser 80W 450Nm For Engraving And Cutting) , Glass Cutting Disk (4-Inch(100Mm) Diamond Cutting Disc For Cutting Glass, Pack Of 4 Pcs, 12000 Rpm) , Teflon Tube (2Mm X 3Mm Ptfe Teflon Tube For 1.5 Mm 3D Printer Filaments) , Bearing (684 Zz Bearing 4X9x4 Shielded Miniature Ball Bearings) , Bearing (628Zz Bearing 8X24x8 Stainless Steel Shielded Miniature Bearings) , Bearing (6901Zz Bearing 12X24x6 Shielded Miniature Ball Bearings) , Bearing (12Mm Bore Inner Ball Mounted Pillow Block Insert Bearing) , Bearing (10Mm Bore Inner Ball Mounted Pillow Block Insert Bearing Kp000) , Bearing (10Mm Inner Diameter Zinc Alloy Pillow Block Flange Bearing Kfl000) , Bearing (8Mm Bore Inner Ball Mounted Pillow Block Insert Bearing Kp08) , Bearing (8Mm Inner Diameter Zinc Alloy Pillow Block Flange Bearing Kfl08) , Bearing (Sc16luu 16Mm Linear Ball Bearing Slide Unit For Cnc - 3D Printer) , Bearing (Sc10luu 10Mm Linear Ball Bearing Slide Unit For Cnc - 3D Printer) , Bearing (Sc8luu 8Mm Linear Ball Bearing Slide Unit For Cnc - 3D Printer) , Bearing (Linear Bearing Lmk12luu 12Mm Square Flange Bushing) , Bearing (Linear Bearing Lmk10luu 10Mm Square Flange Bushing) , Bearing (Linear Bearing Lmk8luu 8Mm Square Flange Bushing) , Lenses (75Mm Achromat Doublet Telescope Objective Lens With 900Mm Focal Length) , Lenses (75Mm Achromat Doublet Lens For Telescope,700Mm Focal Length) , Lenses (50Mm Aperture And 700Mm Focal Length (Make In India Product) F/14 Focal Ratio) , Lenses (Eyepiece For Telescope 10Mm 20Mm -Combo-Pack) , Lenses (Dwij 4Mm Eyepiece For Telescope,0.965) , Lenses (25Mm Non Coated Ramsden Eyepiece For Telescope,0.965) , Lenses (Omni 2X Barlow Lens - 1.25) , Reflector (Front Coated Optical Flat Mirror 25X36mm Diameter,5Mm Thick) , Audio Connector (3.5Mm Trss (Smd) Audio Jack) , Audio Connector (3.5Mm Audio Plug 3 Pole Gold-Plated Earphone Adapter) , Audio Module (Stereo Wireless Speaker Bluetooth 4.0 Audio Receiver Module) , Audio Module (Lm386 Audio Amplifier Module) , Audio Module (12V Stereo Noiseless Audio Power Amplifier Module With 2 X 15W Output) , Audio Module (Audio Dual Channel Stereo Digital Amplifier Board 80W*2) , Audio Speaker (4 Ohm Speaker - 0.5W) , Audio Speaker (8 Ohm Speaker - 0.5W) , Audio Speaker (Electronic Spice 2 Inch Tweeter Speaker Max Power 80W Upto 20Khz Pack Of 2) , Audio Speaker (4 Ohm 30 Watt Hifi Woofer Deep Bass) , Audio Cable (Speaker Cable Red And Black 65 Wire Od 3.6Mm X 7.2Mm - 50 Meter Coil) , Battery (3.7V 1200Mah 4.44Wh Icr-18650 Li-Ion Cell Rechargeable Battery) , Battery (3.7V 6800Mah Icr-21700 Li-Ion High Energy Rechargeable Battery) , Battery Holder (1 X 3.7V 18650 Lithium Polymer (Lipo) Battery Holder) , Battery Holder (2 X 3.7V 18650 Lithium Polymer (Lipo) Battery Holder) , Battery Holder (3 X 3.7V 18650 Lithium Polymer (Lipo) Battery Holder) , Battery Holder (4 X 3.7V 18650 Lithium Polymer (Lipo) Battery Holder) , Battery Charger (3S 10A 12V 18650 Lithium Battery Charger Board Protection Module) , Battery Charger (3 Series 20A 18650 Lithium Battery Protection Board 11.1V 12V 12.6V) , Battery Charger (Lithium Battery Shield V8 Mobile Power Expansion Board Module 5V/3A 3V/1A Micro) , Battery Charger (Micro Usb 2.0 5V 1A 18650 Tp4056 Lithium Li Ion Cell Battery Charger) , V Battery (Panasonic Alkaline 9V Battery) , Connector (5Mm Dc Jack Male-Female Pair Connector With Wire) , Connector (T Style Female Connector With Insulating Cap) , Connector (T Style Male Connector With Insulating Cap) , Connector (Xt60 Male Connectors - 2 Pieces Pack - Genuine) , Connector (Xt60 Female Connectors - 2 Pieces Pack - Genuine) , Connector (Red 55Mm Copper Insulated Crocodile Clip Opening 10Mm For Banana Plug 4Mm) , Connector (Blue 55Mm Copper Insulated Crocodile Clip Opening 10Mm For Banana Plug 4Mm) , Connector (Mt30 3 Pole Motor-Esc Connector Set Female) , Connector (Mt30 3 Pole Motor-Esc Connector Set Male) , Micro Drill Bit (0.1-1.0Mm Mixed 3D Printer Nozzle Cleaning Drill Bit Kit For Mk7 Mk8reprap - 10 Pie) , European Converter (Prime Deal 3 Pin Traveler Conversion Plug) , Extension Board (Board With 4 Universal Sockets, 3 Meter Long Cord, 1500 Watts, 6 Amp Multi Plug) , Led Strip (3528 Blue Smd Led Strip - 5 Meter) , Led Strip (5050 Green Smd Led Strip - 5 Meter) , Led Strip (5050 Red Smd Led Strip - 5 Meter) , Led Strip (5050 Yellow Smd Led Strip - 5 Meter) , Led Strip (3528 White Smd Led Strip - 5 Meter) , Led Strip (3528 Warm White Smd Led Strip - 5 Meter) , Led Strip Programmable (5V Addressable Rgb Non-Waterproof Led Strip - 5 Meter) , Led Strip Programmer (3Key Led Controller For Ws2811 Ws2812b Led Light Strip With Black Dc Jack) , Pv Panels (12V 10W Polycrystalline Solar Panel) , Pv Panels (12V 20W Polycrystalline Solar Panel) , Pv Panels (12V 40W Polycrystalline Solar Panel) , Pv Panels (12V 50W Polycrystalline Solar Panel) , Pv Panels (12V 100W Polycrystalline Solar Panel) , Solar Charger (12V Mppt Solar Charger Module) , Solar Controller (Xy-L10a 10A Lead-Acid Solar Storage Battery Charge Controller Module 6-60V) , Solar Controller (Xy-Cd60 Solar Battery Charger Controller Module Dc6-60V Charging Discharge Protec) , Solar Controller (60A Intelligent Lcd Solar Controller) , Glue Stick (Stanley 1-Gs20dt 100Mm/4X11.3Mm Dual Temperature Glue Stick) , D Print Pen (Goofoo Rp800a-White 3D Printing Pen) , D Pen Filament (3D Printing Pen Pcl Filaments) , Fingerprint Sensor (Grove Capacitive Fingerprint Scanner Module) , Ph Sensor (Industrial Grade Analog Ph Sensor / Meter Pro Kit V2) , Pir Sensor (Smart Digital Human Pir Motion Sensor Bs412 Iot Sensor) , Water Flow Sensor (Liquid Flow Sensor (G1/2)) , Water Gas Flow Sensor (Saier Sen-Hw06k Water Flow Sensor) , Pendrive (Sandisk Ultra Curve 64Gb Usb 3.2 Pen Drive 100Mb/S) , External Hdd (Portable 2Tb External Hdd Usb 3.0) , Brushless Motor (5010 360Kv High Torque Brushless Motor For Drone) , Brushless Motor (5010 750Kv High Torque Brushless Motor For Drone) , Brushless Motor (T-Motor Navigator Mn3110 700Kv) , Brushless Motor (Dys D2822 1450Kv Outrunner Brushless Drone Motor (Original)) , Brushless Motor (Dys D2826 2200Kv Outrunner Brushless Drone Motor (Original)) , Brushless Motor (Dys D2822 2600Kv Outrunner Brushless Drone Motor (Original)) , Dc Motor (615 Magnetic Micro Coreless Motor For Micro Quadcopters - 2Xcw And 2Xccw) , Ac Motor (Mini Sewing Machine Motor (Full Copper Winding) With Speed Controller) , Motor Controller (Brushless Motor Controller Dc 12-36V 500W Pwm Driver Board) , Motor Controller (Jhemcu Blheli_32- 55A 4In1 3-6S Esc) , Flight Controller (Fms Rc Airplane Gyro Reflex Flight Control System) , Flight Controller (Mini Osd With Plastic Shell For Apm 2.6/2.8) , Flight Controller (Sp Racing F3 Flight Controller Integrate Osd Acro Version) , Flight Controller (Apm 2.8 Flight Controller With Built-In Compass) , Flight Controller (Omnibus F4 V2 Pro Flight Controller With Sd Card Slot & Bec) , Flight Controller (Mamba F405 Flight Controller & Rev35 35A Blheli_S 2-6S 4 In 1 Esc) , Transmitter Receiver (Flysky Fs-I6s 2.4Ghz 10 Channel Afhds 2A Rc Transmitter With Fs-Ia10b 10 Channel) , Transmitter Receiver (Flysky Fs-T6 6 Channel Transmitter With Fs-R6b Receiver) , Transmitter Receiver (Frsky R9m 2019 Module And R9mx Receiver) , Transmitter Receiver (Cyclone Xf5804 Switchable Transmitter) , Drone Power Cable (Apm/Pixhawk Power Module V6.0 Output Bec 3A Xt60 Plug 28V 90A) , Propeller (6X4.5 Inch (6045) Hd Propellers Carbon Nylon Props 2Cw+2Ccw - 2 Pairs Black) , Propeller (Hqprop T63mmx8 Light Grey (2Cw+2Ccw)-Poly Carbonate Propeller) , Propeller (10X4.5 Inch - 1045/1045R Cw Ccw Propeller Pair For Quadcopter (Black)) , Propeller (Sunny Sky Eolo 114.5 Inch Propellers- A Pair (Straight Version)) , Propeller (Gemfan 1050-3 Glass Fiber Nylon Propeller) , Propeller (Hobbywing X8 3011 Propellers With Hub Ccw) , Propeller (Hobbywing X8 3011 Propellers With Hub Cw) , Gas Sensor (Mq2 Flammable Gas And Smoke Sensor Module) , Gas Sensor (Mq4 - Methane Natural Gas Sensor Module) , Gas Sensor (Mq6 - Lpg Propane Gas Sensor Module) , Gas Sensor (Mq8 Hydrogen H2 Gas Sensor Module) , Gas Sensor (Mq9 Carbon Monoxide, Methane And Lpg Gas Sensor Module) , Gas Sensor (Mq135 - Air Quality Gas Sensor Module) , E Bike Motor (6 Inch 250W 24V Brushless Hub Motor With Tyre For E-Bike) , E Bike Motor (350W 36V Hub Motor For Electric Bike Bicycle Front) , E Bike Controller (Brushless Controller 24V For Hub Motor 250W) , E Bike Controller (Ebike Brushless Sine Wave Motor Controller 36V For Hub Motor 350W) , E Bike Throttle (Digital Throttle With Key For Ebike) , E Bike Kit (Right Side Geared Ebike Kit My1016z3 24V 350W) , D Printer Nozzel (Complete Kit Of Mk8 Extruder With 0.3Mm Nozzle (Assembled)) , D Printer Nozzel (Complete Kit Of Mk8 Extruder With 0.5Mm Nozzle (Assembled)) , D Printer Nozzel (E3d V6 12V Direct Drive All-Metal Hotend Kit - 1.75Mm) , D Printer Nozzel (1.75Mm Bowden Extruder Full Kit) , D Printer Motherboard (Gt2560 Mainboard - Mega2560) , D Printer Motherboard (Ramps 1.4 3D Printer Controller Board Arduino Mega Shield) , D Printer Motherboard (Mks Gen V1.4 3D Printer Control Motherboard With 50Cm Usb Cable) , D Printer Leveling Sensor (3D Touch Auto Leveling Sensor) , D Printer Leveling Screw (M3 Headed Bed Adjusting Nut Type B For 3D Printers - 4 Pieces Pack) , D Printer Leveling Spring (Heat Bed Spacer Spring For 3D Printer Um2 Ultimaker2 - 4 Pieces Pack) , D Printer Hot Bed (Reprap Mk2b 3D Printers Dual Power Pcb Heat Bed With 14Awg Cable) , D Printer Hot Bed Controller (Mks Mosfet Heating Controller For 3D Printer Heat Bed/Extruder) , D Printer Hot Sticker (220 X 220 X 0.5Mm Frosted Heated Bed Sticker Build Plate Tape With Adhesive Backin) , D Printer Lead Screw (1000Mm Trapezoidal 4 Start Lead Screw 8Mm Thread 2Mm Pitch Lead Screw With Co) , D Printer Lead Screw (500Mm Trapezoidal 4 Start Lead Screw 8Mm Thread 2Mm Pitch Lead Screw With Cop) , D Printer Lead Nut (T8 Anti-Backlash Spring Loaded Nut For Cnc 8Mm Threaded Rod Lead Screw) , D Printer Smooth Rod (1000Mm Long Chrome Plated Smooth Rod Diameter 16Mm) , D Printer Smooth Rod (500Mm Long Chrome Plated Smooth Rod Diameter 16Mm) , D Printer Smooth Rod (1000Mm Long Chrome Plated Smooth Rod Diameter 10Mm) , D Printer Smooth Rod (500Mm Long Chrome Plated Smooth Rod Diameter 8Mm) , D Printer Timing Pully (Aluminum Gt2 Timing Pulley 20 Tooth 8Mm Bore For 6Mm Belt) , D Printer Timing Pully (Aluminum Gt2 Timing Double Head Pulley 20 Tooth 8Mm Bore For 6Mm Belt) , D Printer Timing Belt (10M Gt2 Width 6Mm Black Open Timing Belt For 3D Printer) , D Printer Timing Belt Spring (Tensioner Torsion Spring For Gt2 6Mm Timing Belt Used In 3D Printer - 5 Pieces Pack) , D Printer Linear Guide Rail (Mgn15h Linear Guide Rail - 1M With Sliding Block) , D Printer Linear Guide Rail (Mgn15h Linear Guide Rail - 0.5M With Sliding Block) , Cnc Controller (Cnc Three Axis Stepper Motor Drive Controller Motherboard Compatible With Arduin) , Smd Led (White Led 1210 (3528) Smd Package - 10 Pieces Pack) , Smd Led (Yellow Led 1210 (3528) Smd Package - 10 Pieces Pack) , Smd Led (Red Led 1210 (3528) Smd Package - 10 Pieces Pack) , Smd Led (Green Led 1210 (3528) Smd Package - 10 Pieces Pack) , Smd Led (Blue Led 1210 (3528) Smd Package - 10 Pieces Pack) , Smd Led (Green Led - 0603 Smd Package - 10 Pieces Pack) , Smd Led (Orange Led - 0603 Smd Package - 10 Pieces Pack) , Smd Led (Red Led - 0603 Smd Package - 10 Pieces Pack) , Smd Led (Blue Led - 0603 Smd Package - 10 Pieces Pack) , Smd Led (White Led - 0603 Smd Package - 10 Pieces Pack) , Smd Led (Yellow Led - 0603 Smd Package - 10 Pieces Pack) , Smd Resistor (47 Ohm 0603 Package 1/10W Smd Resistor 5% Tolerance (Reel Of 5000 Pieces)) , Smd Resistor (220 Ohm 0603 Package 1/10W Smd Resistor 5% Tolerance (Reel Of 5000 Pieces)) , Smd Resistor (330 Ohm 0603 Package 1/10W Smd Resistor 5% Tolerance (Reel Of 5000 Pieces)) , Smd Resistor (470 Ohm 0603 Package 1/10W Smd Resistor 5% Tolerance (Reel Of 5000 Pieces)) , Smd Resistor (1.2K Ohm 0603 Package 1/10W Smd Resistor 5% Tolerance (Reel Of 5000 Pieces)) , Smd Resistor (10K Ohm 0603 Package 1/10W Smd Resistor 5% Tolerance (Reel Of 5000 Pieces)) , Smd Resistor (33K Ohm 0603 Package 1/10W Smd Resistor 5% Tolerance (Reel Of 5000 Pieces)) , Smd Resistor (100K Ohm 0603 Package 1/10W Smd Resistor 5% Tolerance (Reel Of 5000 Pieces)) , Smd Resistor (330K Ohm 0603 Package 1/10W Smd Resistor 5% Tolerance (Reel Of 5000 Pieces)) , Smd Microcontroller (Atmega2560 - 16Au Microcontroller - (Smd Package) - Tqfp - 100 Pin Microcontroll) , Smd Microcontroller (Atmega328p - Au Microcontroller - (Smd Package) - Tqfp - 32 Pin Microcontroller) , Smd Rtc Ic (Ds3231 Ic - (Smd Sop-16 Package) - I2c Real Time Clock (Rtc) Ic) , Smd Voltage Regulator Ic (78M05 - 7805 - (Smd To-252/Dpak Package) - 5V Positive Voltage Regulator Ic) , Smd Voltage Regulator Ic (Ams1117-3.3V - Smd Sot-23 Package - Voltage Regulator Ic) , Smd Capacitor (100Uf 50V (Smd) Electrolytic Capacitor - 5 Pieces Pack) , Smd Capacitor (10Uf 50V (Smd) Electrolytic Capacitor - 5 Pieces Pack) , Smd Capacitor (47Uf 35V (Smd) Electrolytic Capacitor - 5 Pieces Pack) , Smd Ic (Ch340g (Smd Sop-16 Package) Usb To Serial Ttl Converter Ic) , Smd Ic (A4988 Ic - (Smd Package) - Stepper Motor Driver Ic) , Drill Bit (20Pcs 0.3-1.6Mm Shank Mini Micro Drill Bit Set Twist Drill) , Drill Bit (13 Pcs Hss Drill Bits 1.5Mm To 6.5Mm In Gradations Of 0.5Mm) , Gps Module (Seeedstudio Grove Gps (Air530)) , Humidifier Module (Dc 24V 36Mm Super Ultrasonic Mist Maker Humidifier Atomizer) , Heartrate Module (Max30100 Pulse Oximeter Heart Rate Sensor Module) , Hot Air Blower (Soldron 8858 Portable Hot Air Blower) , Gesture Sensor (Gy-9960- Llc 3-5V Apds-9960 Rgbgesture Sensor Motion Direction Recognition Mod) , Magnet (3Mm X 1.5Mm (3X1.5 Mm) Neodymium Disc Strong Magnet) , Magnet (5Mm X 3Mm (5X3 Mm) Neodymium Disc Strong Magnet) , Magnet (10Mm X 2.5Mm (10X2.5 Mm) Neodymium Disc Strong Magnet) , Magnet (10Mm X 5Mm X 2Mm (10X5x2 Mm) Neodymium Block Magnet) , Magnet (50Mm X 25Mm X 12.5Mm (50X25x12.5 Mm) Neodymium Block Magnet)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
24.
Public Administrative Department #9363422 Technical Bid
Invites bidder for 1.25 MW online solar power generation for tirth kshetra parli which includes erecting, installing and commissioning of solar panels with below details and specifications and1000 lit solar water heater for tirth kshetra parli which includes erecting, installing and commissioning of solar water heaters with below details and specifications For Non SSR Rate For M C Parli V- 1 Content WritingThe creative writing scope involves the development of narrative content through a structured yet flexible process. It begins with research—supported by books, references, and site visits—and moves through data collection, selection, and consultation with a panel of relevant authorities. The aim is to ensure cultural relevance, thematic consistency, and creative integrity. A team of experienced writers, including those with a background in show and screenplay writing, will lead the storytelling process. The primary writer must have substantial experience—preferably over 15 years— and good credentials in show writing, with a proven ability to handle complex, multimedia-driven narratives. The story evolves into script and screenplay formats, including a technical timeline version to align with visual and sound elements. If musical components are included, lyrics will be written by a professional lyricist with experience in both films and live performances. Dialogue writing, idea translation, and screenplay adaptation into other languages are also part of the scope, overseen by a dedicated language supervisor to ensure linguistic clarity and cultural sensitivity. While certain elements may adapt during the creative cycle, the process will remain focused on delivering a cohesive, original, and production-ready script. The show will be bilingual.The job consists of - Data Collection, Data Selection, Authority team, Creating Ideas, Story writing, Script Draft, Screenplay, Lyric writing, Dialogue writing, Technical timeline Screenplay, Translating ideas, Translating Screenplay, Language Supervison 2 DubbingThe audio production scope includes all processes related to voice recording, dubbing, and language adaptation as required for the project. The process begins with planning and coordination under the supervision of a Creative Director, in consultation with the script and language teams. Dubbing forms the core of the audio workflow. This includes recording of voiceovers and dialogues by both celebrity artists and junior artists, as per casting decisions. Talent coordination, scheduling, and handling of logistics fall under the purview of the Artist Management team, which ensures seamless execution across sessions. All voice recordings will be carried out at a professional audio studio, equipped to handle multichannel dubbing and real-time monitoring. Sessions are overseen by an experienced Dubbing Director, responsible for voice performance quality, tone accuracy, and delivery consistency across versions. Throughout the dubbing phase, a language supervisor ensures linguistic correctness, pronunciation alignment, and translation fidelity—particularly in multilingual productions. Supporting staff, including a designated assistant, will aid in session coordination, script handling, and communication between departments. This is a bilingual project. While the structure of the recording process is generally predefined, flexibility may be exercised based on artist availability, script revisions, or project-specific creative needs. 3 The background music The background music production covers the complete creation of an original score to support the overall mood and narrative of the show. The process is led by a Music Director, assisted by a dedicated assistant, and involves contributions from a Music Arranger and music programmers who develop the structure, orchestration, and digital elements of the composition. Live elements are performed by instrument players and chorus singers, as required by the arrangement. To enhance realism and support on-screen action, foley artists are engaged for the creation of natural, synchronized effects. All music components are recorded in a professional audio recording studio, with the final mix executed in a 7.2 surround sound mixing studio to ensure high-quality, immersive output. While the structure is generally predefined, certain creative decisions may adapt during the process to meet evolving artistic and technical needs. 4 Creating songs- The music production scope for songs includes composition, arrangement, recording, and mixing of original tracks suited to the narrative and emotional context of the project. The process is led by a Music Director, responsible for the overall musical vision, supported by an assistant who coordinates sessions and logistics.A Music Arranger refines the musical structure, harmonies, and instrumentation, while music programmers handle sequencing, layering, and digital sound elements. Instrument players contribute live performances to add depth and authenticity to the arrangement. The vocal component features celebrity singers, selected for their voice quality and public resonance, supported by chorus singers where needed for harmony or scale.All vocal and instrumental recordings are conducted in a professional audio recording studio, equipped for multi-track sessions. The final output is processed and balanced in a 7.2 surround sound mixing studio, ensuring spatial clarity and production-grade sound. Adjustments may be made during the creative process to accommodate performance styles, technical feedback, or evolving project direction. 5 Audio MixingThe final audio mixing phase ensures the integration and balance of all sound elements—dialogue, music, effects—into a polished, immersive audio output. The process is creatively led by a Creative Director, who provides the overall aesthetic and emotional direction for the final sound. A designated assistant coordinates schedules, handles version tracking, and supports communication between departments to maintain workflow efficiency. The mixing is executed in a professional 7.2 surround sound studio, equipped for spatial sound design and high-fidelity output suitable for large-format or immersive playback environments. It is a bilingual Production A Technical Supervisor oversees the process, ensuring all specifications related to format, levels, and playback compatibility are met, while also maintaining quality control across multiple output versions.Final adjustments may vary depending on the nature of the content and platform-specific requirements. 6 Scope for Bilingual -The scope includes complete audio localization of the project into a second language, covering dubbing, background music, and song music production. The process begins with dubbing, involving voice recordings by native-speaking celebrity and junior artists, directed by an experienced Dubbing Director under the creative guidance of the Creative Director. Sessions are conducted in a professional audio studio, with oversight from a Language Supervisor to ensure linguistic accuracy and cultural relevance.The background music is either adapted or recreated to suit the tonal needs of the second language version. This includes re-arrangement, possible re-recording by instrument players, and adjustments led by the Music Director with support from arrangers and programmers. Where applicable, song music production is carried out in the second language, featuring celebrity singers and chorus artists, ensuring lyrical integrity and emotional alignment. Lyrics are adapted and approved by the language and creative teams to retain the original intent while fitting the new languages phonetic and rhythmic structure. All elements—dialogue, music, and effects—are finally mixed in a 7.2 surround sound studio under the supervision of a Technical Supervisor, ensuring cohesion and broadcast-ready quality. Some creative or technical modifications may be made based on language-specific needs or audience expectations. 7 Indoor ShootingThe indoor studio shoot covers all aspects of video production carried out within a controlled studio environment, under the overall vision of the Creative Director. The shoot is planned and executed with the support of a technical supervisor, assistant, and a full production team, ensuring that both creative and logistical aspects are effectively managed.The cast includes celebrity artists and junior artists, whose schedules and coordination are handled by the artist management team. Performance delivery is supported with tools such as a teleprompter and direction provided on set. The production takes place in a professional video studio using high-grade camera equipment, with visuals led by a skilled Director of Photography (DOP). The setup includes a full lighting rig, supplemented by a generator for uninterrupted power supply. For shoots requiring virtual backgrounds or visual integration, chroma key technology is used. Supporting elements include on-location sound setup, makeup, costumes, and props, all arranged to maintain visual consistency with the creative concept. The location and studio logistics are prepared in advance, ensuring readiness for smooth execution. While most elements follow a predefined structure, flexibility is maintained for creative changes, technical adjustments, or talent-related considerations during the shoot. 8 Outdoor ShootingThe outdoor location shoot involves the execution of video production in open, uncontrolled environments, led creatively by a Creative Director and technically coordinated by a Technical Supervisor with support from an Assistant and a full Production Team. This setup ensures both the creative vision and the operational logistics are effectively managed on site.Camera equipment and on-location filming are handled by an experienced Director of Photography (DOP), supported by a custom lighting setup and reliable power supply through generators. The presence of junior artists, along with complete makeup, costumes, and props, helps bring the narrative elements to life during the shoot. To capture wide and aerial perspectives, a drone camera is operated by a trained drone operator, enabling cinematic coverage of the location. On-site sound setup ensures proper dialogue and ambient recording despite outdoor challenges. Comprehensive logistical support is included, covering crew transport, food, and accommodation, ensuring the teams comfort and efficiency during extended schedules. Outdoor management costs account for location permissions, crowd control, weather-related support, and other unforeseen field requirements. While the shoot is planned in detail, flexibility is maintained to adapt to on-site conditions, natural light changes, or last-minute creative directions. 9 Editing The editing phase involves assembling, refining, and finalizing the visual and audio content using professional software platforms such as FCP or Premiere. The process is led by a skilled Editor, working under the creative guidance of the Creative Director, and supported by an Assistant for logistical and coordination tasks. A Technical Supervisor ensures compatibility across formats and monitors workflow consistency. The edit includes detailed color correction and DI (Digital Intermediate) processing to ensure visual consistency, mood enhancement, and output readiness for multiple formats.Simultaneously, sound matching is carried out to align the audio precisely with visual elements, ensuring a seamless viewing experience. While the process follows an established structure, creative and technical adjustments may be made during post-production based on evolving requirement. 10 The concept development The concept development stage lays the foundation for the animation project by defining the core theme, narrative, or message to be communicated through the visual content. This includes interpreting the shows objective and aligning it with the desired emotional, cultural, or historical tone.A clear understanding of the events context—its purpose, audience, location, and scale—is essential at this stage. This helps shape the visual language, pacing, and symbolic elements of the animation. In parallel, the creative team gathers necessary architectural references, including blueprints, elevations, or high-resolution photographs of the projection surface—such as a building façade, monument, or custom structure. These assets are critical for mapping visual content accurately and ensuring that the animation interacts naturally with the physical form of the structure. This stage may involve creative exploration, mood boarding, and draft scripting, with room for refinement based on client input or site-specific constraints. 11 The projection surface analysisThe projection surface analysis phase focuses on the detailed study of the building or structure intended for projection. This includes analyzing its dimensions, contours, architectural features, and physical obstacles such as balconies, columns, or surface irregularities that may impact visual output.Based on this analysis, the team develops a precise 3D model or high-fidelity mock-up of the actual building or façade. This model serves as the reference framework for animation alignment, ensuring that visuals map seamlessly onto the surface and interact accurately with its physical geometry. This step is essential for delivering a high-impact, distortion-free projection experience. 12 The Storyboard & Visual ScriptingThe Storyboard & Visual Scripting phase involves planning the sequence of visuals, defining key scenes, transitions, and impactful moments that shape the overall flow of the animation. This step establishes the visual rhythm and narrative structure of the show. A detailed visual script is developed alongside the storyboard, mapping out how each visual element aligns with music, voiceover, or narration, if applicable. This ensures creative cohesion between the audio and visual components, serving as a blueprint for the animation and production teams during the execution phase.The Asset Creation phase The Asset Creation phase focuses on designing and developing all visual elements required for the animation. This includes creating characters, environments, and props using industry-standard 3D software such as Blender, Maya, or Cinema 4D, depending on project needs. In addition to modeling, the team creates or sources textures, lighting references, and visual effects that enhance the realism or stylistic tone of the animation. These assets form the visual foundation of the project and are tailored to suit the projection surface, storytelling requirements, and overall design direction.The 3D Animation & SimulationThe 3D Animation & Simulation phase involves animating visual elements in precise synchronization with the storyboard and audio, including music, narration, or sound design. This ensures that the visuals follow the intended rhythm and narrative structure. The process includes the addition of dynamic visual effects such as explosions, transformations, morphing, and architectural illusions to enhance the visual experience and create dramatic impact. To complement the content and surface geometry, camera movements and spatial transitions are simulated within the 3D environment, ensuring smooth visual flow and accurate alignment with the unique structure of the projection facade. 13 The RenderingThe Rendering phase involves generating the final animated output in high resolution (typically 4K or higher) to meet the technical requirements of the projection system. This step ensures that all visual elements are produced with maximum clarity and detail.Special attention is given to color accuracy, brightness, and contrast levels, The Audio Synchronization The Audio Synchronization phase involves the mixing of background music, voiceovers, and sound effects (SFX) into a cohesive audio track. This mix is carefully aligned with the visual timeline to ensure seamless integration.Key sound cues are timed precisely with visual events to enhance dramatic impact and emotional engagement. The synchronization process ensures that audio elements not only support but elevate the overall viewing experience.Calibration -The Projection Mapping & Calibration phase focuses on aligning the final animation with the architectural surface using specialized software such as MadMapper, Resolume Arena, or HeavyM. This step ensures that the visual content fits precisely to the buildings structure and features.On-site testing is conducted using actual projectors to fine-tune the mapping. The Final Testing The Final Testing & Show Execution phase involves conducting full-scale tests of the complete animation and audio sequence under actual or simulated show conditions, typically at night to match final lighting environments. This ensures accurate visual impact and technical performance. During testing, the team performs final adjustments to fine-tune synchronization, alignment, and timing across projection, sound, and control systems. All critical elements—transitions, cues, and effects—are reviewed for precision.Comprehensive backup systems are prepared, and the triggering mechanism for the show is tested for seamless execution and reliability, ensuring a smooth and uninterrupted live experience. 14 Concept & Theme DevelopmentThis stage involves identifying the purpose of the show—such as entertainment, branding, or cultural celebration. It includes defining the narrative structure, key visual highlights, and emotional peaks. Visual elements will be carefully aligned with music, narration, or other media components to create a cohesive and engaging experience. 15 Site Analysis & Safety PlanningSite Analysis & Safety PlanningIncludes a detailed survey of the venue to assess dimensions, audience layout, and whether the space is indoor or outdoor. Identifies laser-safe zones and ensures compliance with relevant safety standards. Plans for environmental factors such as wind, dust, reflective surfaces, and addresses power supply and equipment placement needs.Storyboard & Laser DesignInvolves creating a detailed show flow with defined cues for anim+B27ations, effects, and transitions. Includes the design of laser scenes incorporating elements such as text, logos, line art, tunnels, waveforms, and abstract visuals to match the overall narrative and theme.Audio IntegrationInvolves selecting or composing a soundtrack that enhances the laser visuals. Visuals are precisely synchronized to musical beats and cues using timeline-based software to ensure a cohesive and impactful audiovisual experience. 16 Programming the Laser ShowUtilizes specialized software (e.g., Pangolin Beyond, Laser Show Designer, LSX) to design and animate laser graphics. Involves programming scene cues with precise timing, color modulation, and optimizing vector paths to reduce flicker and ensure clean, stable laser projections.Equipment SetupInvolves integration of the control system using a laptop, DMX interface, or timecode-based triggering setup to ensure reliable playback and synchronization of laser and show elements.Show ExecutionInvolves synchronizing the laser show with other elements such as music, lighting, and pyrotechnics. Cues are triggered manually or through automated systems using timecode or MIDI. Real-time monitoring is performed to ensure system performance and maintain audience safety. 17 Objective & Concept DevelopmentDefines the purpose of the lighting design—whether for concerts, architectural highlights, theatrical performances, or event ambiance. Focuses on understanding the emotional tone, thematic direction, and desired audience impact. A creative lighting concept is developed to support the narrative, brand identity, or spatial transformation goals.Venue Analysis & Technical SurveyInvolves assessing the venues dimensions, architectural features, and ambient lighting conditions. Identifies available power sources, rigging points, and spatial limitations such as stage size and ceiling height. A 3D model or detailed layout is created or requested to aid in accurate previsualization and planning.Mood Board & Visual ReferencesCurates visual references for color schemes, lighting styles, fixture types, and integration with stage or set design. A mood board is developed to reflect the artistic direction and align with the client’s brief and creative vision.Lighting Plot & Fixture PlanningInvolves selecting suitable light fixtures such as washes, spots, beams, strobes, LED bars, and moving heads. Plans fixture positions and focus angles on a detailed lighting plot. Assigns control channels, fixture groups, and zoning to ensure efficient programming and operation. 18 Programming & Cue DesignUtilizes professional lighting control software (e.g., GrandMA, Chamsys, Avolites) to program show cues. Lighting sequences are synchronized with music, movement, or stage actions. Includes design of layered transitions such as dimming, color changes, fades, strobes, and dynamic fixture movements.Previsualization & RenderingSimulates the lighting design in 3D environments using tools such as Capture, WYSIWYG, or Depence². Provides rendered images or video previews to the client and production team for review, feedback, and approval prior to on-site setup.On-site Setup & RiggingInvolves coordination with the technical crew to install lighting fixtures, cabling, and rigging infrastructure. Includes focusing lights and adjusting beam angles, sizes, and positions. All units are tested for power, DMX signal integrity, and proper alignment.Rehearsals & Final ProgrammingConducts full run-throughs with live sound, performers, or projected content to validate timing and coordination. Adjusts cue timings, fade curves, and brightness levels based on actual venue conditions. Finalizes and programs the cue stack for show triggering via manual control, timecode, or live operation. 19 Show Planning & Cue BreakdownDefines all technical and creative elements involved in the show, including lighting, video projection, lasers, sound, pyrotechnics, and moving set pieces. Breaks the show into cue points based on timeline, music, or script structure. Timeline & Control System SelectionDetermines the central control method for the show—timecode-based, cue-stack driven, or a hybrid of manual and automated triggers. Selects appropriate software and hardware solutions (e.g., QLab, Timecode Buddy, Watchout, Medialon, Disguise, TouchDesigner, Hippotizer, MADRIX, Reaper). Defines communication protocols such as MIDI, DMX, OSC, TCP/IP, or Art-Net for seamless integration between devices.System Integration & Communication SetupEnsures all show systems—including lighting, video, audio, and mechanical elements—are networked and properly addressable. Sets up protocol routing, such as MIDI triggers for video playback or SMPTE timecode for synchronizing lighting and audio cues. Configures master/slave relationships to establish a reliable sync hierarchy, typically with audio as the master clock. 20 Programming Cue SequencesDevelops a detailed cue list within the control software, assigning precise timings and smooth transitions for each element. Triggers are programmed to execute specific actionsPrevisualization & TestingUses specialized software (e.g., Disguise for video, Capture for lighting, TouchDesigner for interactive elements) to s+B48imulate the full cue stack in a virtual environment. Enables fine-tuning of transitions, timing, and synchronization across systems before on-site setup, helping to identify and resolve potential issues in advance.Rehearsal & On-Site CalibrationConducts full rehearsals using actual show hardware including lighting rigs, projectors, audio systems, and stage mechanics. Fine-tunes cue timings, fade curves, and mechanical movements to match music or video beats. Tests all failsafes, aligns system triggers, and ensures timecode sources are synced with acceptable playback latency across all systems. 21 Digital signal processor - 12 x 8 Networked Digital Signal Processor with 12 inputs and 8 outputs or more; 12 ormore Control Inputs and 6 or more Logic Outputs for GPIO Integration; 48V phantom power on all analog inputs; THD: <0.01% 20Hz to 20KHz; Crosstalk: <-75dB orbetter; Open architecture software configurable; logic processing power; 2 digital audio bus RJ45 Port; 1Ethernet RJ45 port for Monitoring and configuration; Capable to handle +5V unloaded logic output voltage; Should have speech sense engine; Capable to control 3rd party devices with TCP IP and RS232; Should have 1nos of RS 232 port for integration with control System; Should have Bi-Directional Locate Functionality; Should have 48 or more digital audio Channel Bus; Should have monitoring LED for COM, STAT, ERR and PWR; etc.Approved Make: BSS / bi-amp / Symetrix 22 Wall Mount Controller - 8 Buttons Ethernet Controller and Volume Control, Should be Compatible with supplied DSP, Should support PoE (Power Over Ethernet), 8 Programmable Buttons (Multicolored), Capable to trigger any DSP logic, Multicolored 2 Programmable 64x128 Pixel LCDs, Sleep Function, Security: Remote Lock/Unlock and Local Unlock via PIN Entry, Should have knob and capable to control 8 zones separate.Approved Make: BSS / bi-amp / Symetrix 23 Wall mount arrayable speaker.High Power 3-Way Loudspeaker with 15 LF; Frequency Response:(±3 dB): 45 Hz – 18 kHz, Frequency Range (-10dB):38Hz – 20KHz; Coverage Pattern: 90° x 50°, rotatable waveguide, Crossover Modes: Tri-amp/Bi-amp switchable, Transducer Power Rating :LF 4000 W peak , MF 1400 W peak ,HF 400 W peak, LF Driver : 15”; MF Driver : 8” ; HF Driver : 1.5”; Sensitivity LF : 97dB; Sensitivity MF: 108dB; Sensitivity HF: 115dB;Maximum SPL: LF:133 dB peak , MF/HF: 139 dB peak, ; Nominal Impedance: 8 ohms, Grille: Powder coated 14 gauge perforated steel, Enclosure: Trapezoidal with 15 degree side angles.Approved Make: JBL / L-acoustic / d&b audiotechnik 24 Weathrised SpeakerHigh Power 3-Way Loudspeaker with 15 LF; Frequency Response:(±3 dB): 45 Hz – 18 kHz, Frequency Range (-10dB):38Hz – 20KHz; Coverage Pattern: 90° x 50°, rotatable waveguide, Crossover Modes: Tri-amp/Bi-amp switchable, Transducer Power Rating :LF 4000 W peak , MF 1400 W peak ,HF 400 W peak, LF Driver : 15”; MF Driver : 8” ; HF Driver : 1.5”; Sensitivity LF : 97dB; Sensitivity MF: 108dB; Sensitivity HF: 115dB;Maximum SPL: LF:133 dB peak , MF/HF: 139 dB peak, ; Nominal Impedance: 8 ohms, Grille: Powder coated 14 gauge perforated steel, Enclosure: Trapezoidal with 15 degree side angles.Approved Make: JBL / L-acoustic / d&b audiotechnik 25 Subwooferhighpower install grade Dual 18 low frequency loudspeaker systemwith extended frequency range with mounting points for OEM hardware/ bracket. Frequency response: 20Hz to 1KHz (-10 dB) or better, Power rating: 2400W continuous or better; Sensitivity: 99dB or better; Maximum SPL: 135dB or better; Nominal Impedance: 4ohm in parallel and 2X8 ohm in driver mode; LF Driver 18 or better; LFdriver with 4 voice coil.Approved Make: JBL / L-acoustic / d&b audiotechnik 26 Digital Power AmplifierFour channel Digital Network Based Power Amplifier with Power output 4 x 2400W @ 4 Ohms / 8 Ohms; should support 70Vrms and 100Vrms output on all output channels; THD 0.35% or better; Should support Cooling Continuously variable speed forced air; Voltage Gain 34dB or more; Digital bus compatibility up to 8 or more audio channel; bridgeable channels - even in 100Vrms mode for 200Vrms Output; 2digital audio bus RJ45 port; 1 Ethernet R 45 port for monitoring and configuration;Should have DSP features incl. Limiters , Input/output EQ ,Delay ,Matrix Mixer ,Speaker Line Monitoring; Damping Factor (20 Hz to 100 Hz) : >5000 or more; etc.Approved make: Crown / RAM Audio / Labgrupen 27 Digital Power AmplifierMultichannel Digital Network Based Power Amplifier with Power output 4 x 1250W or better @ 4 Ohms / 8 Ohms; Should support 70Vrms and 100Vrms output on all output channels; THD 0.35% orbetter; Cooling Continuously variable speed forced air; Voltage Gain 34dB ormore; Digital bus compatibility up to 8 or more audio channel; bridgeable channels even in 100Vrms mode to operate with 200Vrms output; 2digital audio bus RJ 45 port; 1 Ethernet R 45 port for monitoring and configuration; Should have DSP features like Limiters , Input/output EQ , Delay ,Matrix Mixer ,Speaker Line Monitoring; Damping Factor (20Hz to 100Hz) : >1500 ormore; etc.Approved make: Crown / RAM Audio / Labgrupen 28 Digital Power AmplifierMultichannel Digital Network Based Power Amplifier with Power output 4 x 600W @ 4 Ohms / 8 Ohms or better; Should support 70Vrms and 100Vrms output on all four channels; Frequency Response: ±0.25dB or better; Total Harmonic Distortion: 0.35% or better; Voltage Gain: 34dB or better; Damping Factor(20Hz to100Hz): >1000 or better; Signal to Noise Ratio: >108dB or better; Cooling: Continuously variable speed forced air, front to back airflow; bridgeable channels even in 100Vrms mode to operate with 200Vrms output; 2digital audio bus RJ 45 port; 1 Ethernet R 45 port for monitoring and configuration; Should have DSP features like Limiters, Input/output EQ, Delay, Matrix Mixer, Speaker Line Monitoring.Approved make: Crown / RAM Audio / Labgrupen 29 Digital Power AmplifierMultichannel Digital Network Based Power Amplifier with Power output 8 x 300W @ 4 Ohms / 8 Ohms or better; Should support 70Vrms and 100Vrms output on all Eight channels; THD 0.35% or better; Damping Factor (20 Hz to 100 Hz): >1000 or better; Frequency Response: ±0.25dB or better; Signal to Noise Ratio: >108dB or better;Cooling: Continuously variable speed forced air, front to back airflow; Voltage Gain: 34dB or better; Audio Digital channel bus compatibility up to 8 channel, bridgeable channels - even in 100Vrms mode, 2 digital audio bus RJ 45 port, 1 Ethernet R 45 port for monitoring and configuration, Should have Limiters, Input/output EQ, Delay, Matrix Mixer, Speaker Line Monitoring.Approved make: Crown / RAM Audio / Labgrupen 30 Stage Monitors 1 x 12 LF; 2-Way Stage Monitor Speaker System; Power Rating 300W at 8 Ohms; etc.Approved Make: JBL / L-acoustic / d&b audiotechnik 31 2.5 sq mm multi stranded speaker cable 32 1.5 sq mm copper multi strandedcable 33 2 core shielded 23/36 cable 34 XLR connector 35 Speak on male and female connector 36 Jack Pins 37 RC Pins 38 EP pins 39 18U audio RackBrand - ‎RIVECO / Manufacturer - ‎RIVECO / Model - ‎OF5518 / Model Name - ‎OF / Product Dimensions ‎55.12 x 50.04 x 90.17 cm; 12.25 kg / Item model number ‎OF5518 / Compatible Devices - ‎Server / Material- ‎Alloy Steel / Manufacturer - ‎RIVECO Item Weight- ‎12 kg 200 g 40 Analog Mixer – 10-channel mixing console with 4 mono mic/line inputs featuring D-PRE Class-A preamps, +48V phantom power, one-knob compressors, 3-band EQ, high-pass filters, and 3 stereo line inputs; integrated SPX digital multi-effects processor with 24 presets; built-in 24-bit/192kHz USB audio interface (2-in/2-out); balanced XLR and TRS main outputs, monitor out, FX send, and headphone output; rugged metal chassis (244 x 71 x 294 mm, approx. 2.1 kg); includes external PA-10 power supply. Suitable for professional live sound and studio recording applications.Approved Make - Yamaha, Mackie, Beheringer 41 Microphone (with cable) – Dynamic cardioid vocal microphone designed for professional live vocals and studio use, featuring a tailored frequency response of 50 Hz to 15 kHz for clear vocals and speech, uniform cardioid pickup pattern for excellent off-axis rejection, pneumatic shock mount system to reduce handling noise, built-in spherical wind and pop filter, rugged steel mesh grille, and durable metal construction; output impedance of 150 ohms, sensitivity of –54.5 dBV/Pa (1.85 mV), and XLR 3-pin connector.reliable, clarity, and stage durability.Approved Make - Shure, Sennheiser 42 Microphone Stand – Heavy-duty, adjustable-height microphone stand with tripod base or round base options, suitable for studio and stage use; features height adjustment clutch, extendable boom arm (where applicable), and standard 5/8 mic thread mount. Recommended brands: K&M (König & Meyer), Hercules, QuikLok, Samson, and Maplin. Ensure compatibility with dynamic and condenser microphones for versatile application 43 Installation, Testing & Commissioning of Sound System – Involves installation of speakers, mixers, amplifiers, processors, microphones, and cabling as per design; proper mounting, wiring, and termination with safety and signal integrity checks; system calibration including level setting, equalization, and time alignment; verification of all input/output signal paths; integration with AV or control systems if required; conducting performance tests to ensure clarity and coverage; final tuning, user orientation, and handover of a fully functional audio system. 44 Image - brightness (lumens) - • 17,800 ISO /15,000 ANSI • 23,750 ISO /20,000 ANSI color wheel• 4 segment – 3X speedDisplay technology - type - 1 x 0.8 HEP DMDresolution - WUXGA • 1920 x 1200 (2,304,000 pixels) (16:10)Illumination - type - High efficiency blue laser phosphor / performance, 20,000 hours to 50% brightness at full power mode, 50,000 hours to 50% brightness at ECO1 modeSignal Inputs - standard - HDMI 2.0b x 2 (HDCP 1.4/2.2) • 3G-SDI x 1 (BNC) -Display Port x 1(1.2a) • USB 2.0 x 1 (Type A) • HDBaseT - 1.0 (RJ45) x 1signals - Horizontal and vertical scaling while maintaining aspect ratio (all inputs)3D-Active shuttered - HDMI 1.4, HDBaseT – frame packing, top/bottom, side-by-side at 1080p at 60Hz frame sequential WUXGA(RB) up to 120 Hz. - 3D sync in (BNC) – for genlocking 45 projectors - 3D sync out (BNC) – for genlocking projectors, or controlling emitter or polarizerpixel clock - 600MHzscan rates - Horizontal: 15.375 kHz ~ 135.0 kHz ; Vertical: 23.98 Hz ~ 120 Hz -Signal Outputs monitor out (loop-through) - 3G-SDI x 1 (BNC) • HDMI x 1 (HDMI out)Control and networking -HDBaseT (RJ45 x 1) /RJ45 x 1 (Ethernet Control over wired network connection) / RS232 x 1 / Remote in: 3.5mm stereo female (provides serial communications and power) / DC JACK 12 VDC, 200 mA maxTAA-compliant - Yes 46 Lenses - mount type - Boresight adjustable - Motorized horizontal and vertical lens offset (memory available) / Motorized zoom and focus adjustment (memory available for full ILS lenses)lens options - 0.46:1 UST lens - • 1.8-2.4:1 zoom lens • 2.4-4.8:1 zoom lens • 4.8-8.64:1 zoom lens • 8.64-12.96 zoom lensAccessories - standard - IR remote with wired remote jack (wire not included) • AC line cord for projector • Product Safety Guide 47 Installation testing and comminssioning -Includes unloading, positioning, and secure rigging or ceiling/truss mounting of high-lumen projectors as per projection plan; connection of power supply, signal inputs (HDMI, SDI, DVI, DisplayPort, or HDBaseT), and control interfaces (LAN, RS232, or remote protocols); alignment of projectors with screen surfaces or projection areas using lens shift, zoom, and keystone adjustments; implementation of edge blending, warping, and soft/hard masking where multiple projectors are used; calibration for brightness, color uniformity, and geometry using test patterns or software tools; full testing for input responsiveness, synchronization with lighting/audio cues, and heat management; integration with media servers, automation or timecode systems; final run-throughs and commissioning for stable operation and visual consistency during the show. 48 The PAR 180 RGBW IP is a powerhouse in the realm of LED lighting. Boasting 54X3W RGBW LEDs, it offers a vibrant array of colors with precision. Constructed with robust die-cast aluminum housing and an efficient heat sink, it ensures durability and minimal power consumption. Its slim profile accommodates five lens angle options, providing flexibility for various lighting applications. Whether for professional setups or outdoor events, this PAR delivers reliability and versatility in every illumination.Voltage - AC115-230V, 50/60 Hz / Power120W / Lamp source 54X3W RGBW 6000K Life / Color temperature / time 80000h / Lens angle15/25/20/45/60 ° / Channel 4/8 CH / Control mode DMX512, master-slave, auto, sound control / IP Rating IP65 / Net Weight 5.5 KG / Gross Weight 12.6 KG (Cardboard packing 2in1) / Package 60 X 30 X 33 CM (Cardboard packing 2in1) 49 Moving Heads - Rainbow 300:- Model No. :-11001001 Lamp Type :- Philips MSD 250W / Osram HRI 251W ,Average Life :- 1500 hours ,Color Temperature :- 7800K / 7890K ,Reflector :- Lamp and reflector combined in one unit ,Lens :- High-precision optical lens ,Beam Angle :- 0°–4° ,Color Wheel :- 13 Color Filters + Open ,Effects :- Rainbow effect can be created ,Gobos :- 12 Fixed Gobos + 4 Glass Gobos + Open ,Effects :- Shake effect,Frost Effect :-Independent frost soft effect,Dimming :- Mechanical linear 0–100% dimming ,Strobe Effects :-Fast strobe, pulse / asynchronous / synchronous / random speed ,Prism Wheels :- 3 Total: • 1 x 8+8+8 Honeycomb Prism (Self-rotating) ,• 1 x 8 Circular Prism (Self-rotating) ,• 1 x 8+16 Facet Circular Prism ,Optional Prism :-6 Facet Linear Prism,Total Prism Effects :- 7 ,Pan Range :- 540°,Tilt Range :-270° ,Reset System :-Electro-optic auto-reset system ,Control Channels :- 16CH / 20CH ,Control Modes :-DMX512, RDM (Optional), Auto Run, Sound ,Addressing Option :-Type-C Socket (Powerbank compatible) ,Menu Display :-LCD with 16 million pixels, 180° rotatable,Fan Control :- Intelligent fan control ,Sensor Detection :- Electronic sensor detection ,DMX Monitoring :- DMX control monitor,Motor Drive :- X/Y Two-phase motor drive,LCD Features :- Parameter query available 50 Moving Heads - Rainbow 600 (Wall washer) ,Model No. :-11001021 ,Lamp Type ,OSRAM HRI 420W / Philips MSD 420W ,Average Life :- 2500 hours ,Color Temperature :- 7600K / 8000K .Reflector :- Lamp and reflector combined in one unit , Lens :- High precision optical lens ,Beam Angle :-2.8° ,Color Wheel :-14 Color Filters + Open,Effects :- Rainbow color effect ,Gobos:- 12 Fixed Gobos + 4 Glass Gobos + Open ,Effects :-Shake effect,Frost Effect :-Independent frost soft effect ,Dimming:- Mechanical linear 0–100% dimming ,Strobe Effects :-Fast strobe, pulse / asynchronous / synchronous / random speed ,Prism Wheels :-2 Total: :-• 1 x 8+8+8 Honeycomb Prism (Self-rotating) ,• 1 x 8 Facet Circular Prism (Self-rotating) ,Total Prism Effects:- 3,Pan Range :- 540° ,Tilt Range :- 270° ,Reset System :- Electro-optic auto-reset system,Control Channels :- 16CH / 20CH ,Control Modes :-DMX512, RDM (Optional), Auto Run, Sound ,Addressing Option :- Type-C Socket (Powerbank compatible),Menu Display :-LCD with 16 million pixels, 180° rotatable,Voltage :- AC100-240V 50/60Hz,Ballast :- Electronic ballast ,Power Consumption :- 600W,Clamp Type:-Inbuilt folding clamp ,Product Dimensions :-38 x 32 x 66 CM,Net Weight :-20KG,Flight Case Packaging (2 in 1):-78.5 x 46 x 89.5 CM ,Gross Weight :-60KG 51 DMX Spliter 8C :- Take control of your lighting rig with the DMX SPLITTER 8CH 2 IN1. Amplify your DMX signal to four independent outputs, providing greater fixture control and scalability for large-scale events and intricate lighting designs. With impeccable signal integrity and flexible configurations, this splitter is the perfect choice for demanding outdoor environments, touring artists, and rental companies seeking reliable performance and stability.Power input :- AC120V-240V 50Hz/60Hz ,Consumption :-20W ,Net Weight :- 2.4 KG,Gross Weight :- 14 KG ,Cardboard packing :- (5in1),Package :- 51X24X48 CM 52 Haze :-DFZ-2100 is a top of the range water-based haze machine designed for the professional market. It has strengthened its performance than its predecessor, comes built-in flight case and can be stacked one on another. DFZ-2100 haze machine features a unique heating system which enables to produce continuous even haze, free from clogging, reduce maintenance and extend product life. Operating at low noise levels makes it an ideal choice for noise-sensitive environments, including theaters, stages, studios and high-end bars.,Power :-1200W ,Voltage:- AC220V-240V/50-60Hz .Warm-up time :- Appr. 2 Min,Fuel consumption :-83 Min/L ,Tank capacity:- :-5 ltr. ,Max output volume:- 12000 cuft / Min,DMX Channel :-2,DISPLAY :-LCD-2,Net Weight :- 14 KG , Gross Weight ,16 KG ,P Dimensions :- 51×39×26.5 CM ,C Dimensions:- 59×47.5×33.5 CM 53 Cables:- 2.5 sq mm cable 54 Connectors -Includes supply and installation of professional-grade connectors for stage lighting such as XLR (3-pin/5-pin) for DMX signal, PowerCON and True1 for secure power connections, and EtherCON for network-based lighting protocols like Art-Net or sACN; all connectors to be heavy-duty, locking type, and suitable for touring or fixed installations, ensuring reliable signal transmission, power safety, and system durability; recommended brands include Neutrik, Amphenol, and Seetronic. 55 Poweboard -Custom-designed power distribution board for stage lighting, equipped with industrial-grade MCBs, RCBOs, power indicators, and socket outlets (16A/32A/63A as required); includes multiple protected outputs for connecting lighting fixtures and dimmers, with proper earthing, load balancing, and surge protection; housed in a rugged enclosure suitable for indoor/outdoor use; ensures safe and reliable power supply for all stage lighting equipment; recommended components from brands like Legrand, Schneider Electric, or L&T. 56 Installation - Involves mounting and rigging of lighting fixtures (LEDs, movers, PARs, etc.) on trusses or grids, routing and termination of power and DMX/control cables, addressing and patching of fixtures, integration with lighting console via DMX or Art-Net, testing for power, control signal, and fixture functionality; includes alignment, focusing, and basic programming as per show design; all work to comply with safety standards and rigging best practices. 57 lamp power:- 40W,Laser power :-Red:10000mw Green:15000mw Blue:16000mw ,Power consumption :-760W,Wavelength :-Red:638mw Green:525mwBlue:450mw,Laser source :- Diode(NICHIA) ,Colors :- RGB full color ,External Modulation :-100K Analog, TTL,DMX Channel :- 19CH/32CH,Scanner system :- 50kpps☑,Laser source :- Diode(NICHIA),Colors :-RGB full color, External Modulation :- 100K Analog☑ TTL☑,DMX Channel :-19CH/32CH,Scanner system :- 50kpps 58 Timecode reader for Laser Show – Device used to read and decode SMPTE/LTC timecode signals for precise synchronization of laser projections with audio, lighting, and video cues; ensures frame-accurate playback and seamless integration with laser control software; supports industry-standard timecode formats, offers stable input detection, and is compatible with show controllers and timeline-based systems. Recommended brands -Pangolin, LaserAnimation Sollinger, and Showtacle 59 License Key for Laser Show Software – Official software authorization key required to unlock full features of professional laser show control applications such as Pangolin QuickShow, BEYOND, or Showtacle Moncha.NET; enables access to advanced timeline programming, multi-laser control, DMX/Art-Net integration, 3D animation tools, and real-time synchronization with audio, video, and lighting systems; delivered as a hardware dongle or digital activation key. Essential for legal use and operation in professional multimedia and laser show productions. 60 InstallationIncludes mounting and alignment of laser projectors at designated locations, secure rigging with safety measures, routing and termination of power, signal, and control cables, integration with control systems (DMX/Art-Net/ILDA), installation of safety interlocks and emergency stop switches, basic lens and beam path alignment, and ensuring compliance with safety standards; system tested for alignment, coverage, and synchronization with multimedia content before handover. 61 Server :- Operating System -Windows 10 or Windows 11 (64-bit), macOS 10.15 (Catalina) or later,Processor- Recommended: Intel Core i7 or AMD Ryzen 7, Minimum: Intel Core i5 or AMD Ryzen 5 :- Recommended: Intel Core i7 or AMD Ryzen 7, Minimum: Intel Core i5 or AMD Ryzen 5,Recommended: 16 GB or more, Minimum: 8 GB.Graphics Card :- Recommended: NVIDIA GeForce RTX 4060 with 6 GB VRAM, Minimum: NVIDIA GeForce GTX 960 with 2 GB VRAM,Storage:- Recommended: SSD with 10 GB free, Minimum: 5 GB free space ,Video Inputs :-HDMI x 2 (HDCP 2.2 compliant), DisplayPort x 1 (version 1.2), DVI-D x 1 (digital only), USB x 1 (Type A),Video Outputs :- HDMI x 1, 3G-SDI x 1 (BNC),Optional Video Inputs :- HDBaseT (RJ45 x 1), Terra SDVoE, 3G-SDI x 1 IN (BNC), 3G-SDI x 1 OUT (BNC), WiFi Dongle,Audio Outputs :- Stereo output via 3.5mm jack or HDMI,Networking:- Ethernet (10/100/1000 Mbps), WiFi (optional) ,Resolution Support :- Max: 4096 x 2160 @ 60Hz, Min: 480i @ 60Hz,Frame Rate Support :- Horizontal: 15-91 kHz, Vertical: 24-120 Hz,Pixel Clock :- Max: 594 Mpix/s (supports high resolutions and refresh rates),3D and HFR Support :- 3D Formats: Frame packed, top/bottom, side-by-side (up to 120Hz), Optional Input: Up to 1920 x 1080 @ 120Hz,Control Interfaces :- RS-232, MIDI/OSC, Web Interface,Networking and Remote Control :- Ethernet (10/100/1000 Mbps), WiFi (optional) ,Warping and Blending :- Built-in warping and blending, compatible with external video processors and controllers,Standard Accessories :- Power cable, manuals,Optional Accessories :- External control interfaces, additional storage ,Operating Voltage :- 100-240 VAC @ 50/60Hz ,Power Consumption :- Max: ~250-500W (varies by configuration) Power Management :-Various power-saving modes available, Operating Temperature :- 50-95°F (10-35°C),Operating Humidity :- 10-80% non-condensing, Warranty :-1-3 years parts and labor (varies by manufacturer and region), extended support available :-24/7 support available from manufacturer or authorized dealers 62 Laptop :- Hard Disk Size 512 GB, CPU Model Intel Core i7,Processor: 13th Generation Intel Core i7 1255U Up To 4.7GHz ,Operating System: Pre-loaded Windows 11 | ,Laptop, Power Adapter and User Guide,Display: 38cm 16:10 FHD (1920x1080), 60Hz 45%NTSC IPS-Level,Memory & Storage: 8GBx2 DDR5 Onboard Dual Channel RAM | Storage: 512GB NVMe PCIe Gen3x4 SSD,Intel Iris Xe Graphics | 802.11 ax Wi-Fi 6 + Bluetooth v5.2 63 DeskTop - High-performance desktop workstation comprising AMD Ryzen 9 7900 processor, compatible ATX motherboard with PCIe 5.0 support, 32GB DDR5 RAM (2x16GB, 6000MHz), 1TB NVMe Gen4 SSD (Samsung 980 Pro or equivalent), NVIDIA RTX 4060 Ti 8GB GPU, 750W 80+ Gold certified power supply, mid-tower cabinet with efficient airflow and acoustic insulation, 240mm liquid CPU cooler, 27” QHD IPS monitor with 99% sRGB coverage (Dell UltraSharp or equivalent), professional-grade audio interface (Focusrite Scarlett 2i2 or equivalent), and Windows 11 Pro OS. All components to be compatible for seamless performance in professional audio-video editing, mixing, 3D rendering, and multimedia production workflows. 64 Automation console - watchout :- Multi-display and multi-resolution support , · Timeline-based show creation,· Real-time show control via TCP/IP,· Live video input (NDI®, SDI, HDMI, capture cards),· Audio playback and synchronization,· External control via MIDI, Art-Net, DMX, and other protocols,· Support for image sequences (e.g., PNG, TIFF), videos (H.264, HAP, ProRes, etc.),· Automation and scripting support,· Support for 4K/8K+ playback (hardware dependent),· Geometry correction and soft-edge blending,· Output synchronization across multiple display servers 65 External Hard disks :- Brand - ‎LaCie / Manufacturer - ‎Lacie, Seagate, Series - ‎D2 Professional / Form Factor - ‎3.5-inch / Item model number - ‎STHA8000800 / Hard Drive Size - ‎8 TB / Hard Disk Description - ‎Mechanical Hard Disk / Hard Drive Interface -‎USB 3.0 / Hard Disk Rotational Speed - ‎7200 RPM/ Hardware Platform - ‎PC, Mac / Operating System‎mac os / Included Components - ‎LaCie® d2 Professional; USB-C (USB 3.1 10 Gb/s) cable; External power supply; Quick Installation Guide; Rescue Data Recovery Services4 / Manufacturer - ‎Lacie 66 Weatherproof canopies for projectors and speakers -Supply, fabrication, and installation of custom-designed weatherproof canopies for outdoor projectors and speakers, constructed using powder-coated mild steel, stainless steel, or aluminum with UV-resistant polycarbonate or acrylic panels (for projector visibility), designed to protect equipment from rain, sunlight, dust, and wind. Each canopy shall include a sloped roof for water drainage, IP55 or higher ingress protection rating, proper ventilation to prevent overheating, lockable access panels for maintenance, vibration-dampening mounts (for speaker housings), and suitable mounting provisions (wall, ceiling, or pole). All materials must be anti-corrosive and suitable for long-term outdoor use. Installation shall follow manufacturer guidelines and site conditions. Approved Makes / Equivalent: Tempest, Chief (Legrand), Peerless-AV, SunBriteTV, Vanco, Middle Atlantic, or equivalent.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Maharashtra View Result →
25.
Educational and Research Institute #9319703 Technical Bid
Purchase Of Equipments For Project Lab In Eee Department , Arduino Uno Board Specifications Microcontroller: Atmega328p Operating Voltage: 5V Input Voltage ( Recommended ) : 7-12V Input Voltage ( Limit ) : 6-20V Digital I / O Pins: 14 ( Of Which 6 Provide Pwm Output ) Pwm Digital I / O Pins: 6 Analog Input Pins: 6 Dc Current Per I / O Pin: 20 Ma Dc Current For 3.3V Pin: 50 Ma Flash Memory: 32 Kb ( Atmega328p ) Of Which 0.5 Kb Used By Bootloader Sram: 2 Kb ( Atmega328p ) Eeprom: 1 Kb ( Atmega328p ) Clock Speed: 16 Mhz Led_Builtin: 13 Length: 68.6 Mm Width: 58.4 Mm Weight: 25 G , Gsm Gprs Quad Band Ttl Uart Modem - Sim800 At Command Interface Quad-Band 850 / 900 / 1800 / 1900Mhz Make And Receive Voice Calls Send And Receive Sms Messages Send And Receive Gprs Data ( Tcp / Ip, Http, Etc. ) Bluetooth Connectivity Configurable Baud Rate ( 9600-115200, Factory Default Value: 9600 ) Standard Audio Jack Connectors For External Speaker And Mic Selectable Interface Between Hardware Serial Port And Software Serial Port Inbuilt Powerful Tcp / Ip Protocol Stack For Internet Data Transfer Over Gprs. Sma Connector With External Antenna Indicator Leds For Power, Netlight And Status Standard Flap Type Sma Socket Esd Protection Over Tvs Zener Array Input Voltage: 5V-12V Dc Normal Operation Temperature: -20 °C To +55 °C , Nodemcu32 Esp32 Wireless Module Compliant With Bluetooth V4.2 Br / Edr And Ble Specification Class-1, Class-2 And Class-3 Transmitter Without External Power Amplifier Frequncy Range: 2.4 Ghz ~ 2.5 Ghz 520 Kb ( 8 Kb Rtc Fast Memory Included ) Of On-Chip Sram For Data And Instructions. Integrated 802.11 B / G / N Wifi Transceiver 2.2 To 3.6V Operating Range Operating Current : 80Ma Operating Temperature Range: -40°C ~ +80°C , Lidar-Lite V3 ( Resolution: 1 Cm Typical Accuracy: + / - 2.5Cm At Distances Greater Than 2 Meters Range: 5Cm To 40M Update Rate: Greater Than 1Khz Interface: I2c Or Pwm Power ( Operating Voltage ) : 4.75-5Vdc; 6V Max Current Consumption: 65Ma Idle; 85Ma During Acquisition Operating Temperature: -20°C To 60°C Laser Wave Length / Peak Power: 905Nm / 1.3W Beam Divergence: 8M Radian Optical Aperture: 12.5Mm Water Rating: Ipx7 ) , Raspberry Pi 4 Model B With 4Gb Ram Specifications Model-Raspberry Pi 4 Model-B Processor- Broadcom Bcm2711, Quad-Core Cortex-A72 ( Arm V8 ) 64-Bit Soc @ 1.5Ghz Ram Memory - 4 Gb Lpddr4 Sdram Connectivity:- 2 × Usb 2.0 Ports 2 × Usb 3.0 Ports 2.4 Ghz And 5.0 Ghz Ieee 802.11B / G / N / Ac Wireless Lan, Ble Gigabit Ethernet Bluetooth 5.0 Operating Power:- 5 Volt 3 Ampere Dc Via Gpio Header 5 Volt 3 Ampere Dc Via Usb Type-C Connector Power Over Ethernet ( Poe ) –Enabled ( Requires Separate Poe Hat ) Gpio- ( Fully Backward Compatible With Previous Boards ) Multimedia:- H.264 ( 1080P60 Decode, 1080P30 Encode ) ; H.265 ( 4Kp60 Decode ) ; Opengl Es, 3.0 Graphics , Raspberry Pi 4 Usb-C Power Supply - 5.1V, 3 A Specifications 5.1V / 3.0A Dc Output 96-264Vac Operating Input Range Short Circuit, Overcurrent And Over Temperature Protection 1.5M 18 Awg Captive Cable With Usb-C Output Connecto , Quadcopter Crazyfile 2.0 , Fly Sky Ct6b 6 - Channel ( Transmitter + Receiver ) , Rc Remote For Quad Rotor , Stm32 Discovery ( Stm32 F4 ) , Ti C2000 Launchpad ( Tms320f28027 ) , Mosfet Drivers Tlp 250 Driverinput Threshold Current: If=5Ma ( Max. ) Supply Current ( Icc ) : 11Ma ( Max. ) Supply Voltage ( Vcc ) : 10-35V Output Current ( Io ) : ±1.5A ( Max. ) Switching Time ( Tplh / Tphl ) : 1.5?S ( Max. ) Isolation Voltage: 2500Vrms ( Min. ) Maximum Operating Insulation Voltage: 630Vp , Mosfet Ipm Module, Power Device: Mosfet Voltage Rating ( Vces / Vdss ) : 500V Current Rating ( Ic / Id ) : 7A Isolation Voltage: 1500Vrms Ipm Case Style: Spm5q-023 Ipm Series: Spm5 Product Range: Motion Spm 5 Series , Igbt Ipm Module Short-Circuit Rugged Igbts 3.3 V, 5 V, 15 V Cmos / Ttl Inputs Comparators With Hysteresis And Pull Down / Pull Up Resistors Under Voltage Lockout Internal Bootstrap Diode Interlocking Function Smart Shutdown Function Comparator For Fault Protection Against Over Temperature And Over Current Dbc Leading To Low Thermal Resistance , Igbt Drivers ( Semikron, Dual ) No. Of Channels: 2Channels Driver Configuration: Half Bridge Power Switch Type: Igbt No. Of Pins: 40Pins Driver Case Style: Pcb Supply Voltage Min: 14.4V Supply Voltage Max: 15.6V Operating Temperature Min: -40°C Operating Temperature Max: 85°C Input Delay: 1.1?S Output Delay: 1.1?S , Bluepill Stm32f1038mhz And 32768Hz Crystal Circuit Onboard, Micro Usb Based Power Supply Circuit Core With 64K Flash And 20K Sram , Fpga Kits ( Development Board, Xilinx Artix-7 Fpga, Usb-Jtag Programming Circuit, Usb-Uart Bridge ) , Fpga Kits ( Development Board, Basys 3 Artix-7 Fpga, 7-Segment Display, 16 User Switches, 16 User Leds ) , Pcb Toner Tranfer Laminator ( Lamination Width 330 Mm Lamination Speed 475 Mm 4 High-Quality Rollers Metal Gears For Strength & Durability Forward / Reverse Switch Hot / Cold Switch ) , Copper Clad 6*4 Inch Size 25Nos. , Tray For Pcb Etching / Developing 210 X 150Mm Dish , Pcb Drill ( Bench Type And Hand Drill ) , Soldering Iron ( Soldron 25W ) , Multimeter ( 500V Ac / Dc 10A Dc Uni-T Ut33d Multimeter ) , Multimeter ( Promo Fluke 113 / Iphs1 ) , Lcr Meter, Hand Held, 100 Khz, 2 Kh, 20000 ?F, 0.2 Gohm Tenma , Solar Panels ( Watt: 50 W ) , Soldering Stationmax. Power : 90 W Temperature Range : 80ºc - 480ºc Display : 3 Digits L.E.D. Temperature Stability : ± 2ºc ( Stationary Air, No Load ) Tip To Ground Resistance : < 2 O Tip To Ground Potential : < 2 Mv Unit’S Power Consumption : 220 V ) , Rheostats 100 Ohm 2A , Isolation Transformer ( Power 1Kw Input Voltage 230V, Single Phase . Material Copper Line Frequency 50 Hz , Isolation Transformer ( Power 100W Input Voltage 230V, Single Phase . Material Copper Line Frequency 50 Hz , Bldc Motor And Loading Setup ( Bldc 48V , Rated Speed 3000Rpm , Torque 4.5Nm , Power 1Kw , Rated Current 35 A ) , Controller For Bldc Drive ( Non Programmable ) Rated Dc Voltage ( Volts ) :- 48 Over Voltage Cut-Off ( Volts ) :- 58 Under Voltage Cut-Off ( Volts ) :- 41 Commutation Angle ( Degrees ) :- 120 Rated Power ( Watts ) :- 1000 Rated Current ( Amperes ) :- 40 Operating Temperature ( ? ) :- -20 To 80 Protection Class:- Ip 33 Brake De-Energize: High Throttle Voltage: 1V To 4.5V , Controller For Bldc Drive ( Programmable ) Rated Voltage - 48 V Rated Current - 16 A Peak Current - 21 A Rated Rpm - 450 Consumption - 750 W To 1000 W Efficiency - 83% Hall Sensors - 3 Mcu - Stm 32 Frequency - 64 Mhz Input Voltage - 48 V , Dc Geared Motors , Voltage: 12Vdc Rated Torque: ~1.122 Kg.Cm ( 110 Mn.M ) Rated Speed: 430 Rpm Rated Power: 7 W Gear Ratio: 14:1 Encoder Output: 98 Ppr ) , Two Channel Dso Specifications: Bandwidth: 50Mhz ( Or Better ) , Real-Time Sampling Rate: 1Gsa / S, ( Or Better ) Analog Channels: 2, Display: 7” Tft Lcd Color Record Length: 20Kpoints ( Or Better ) , Time Base: 2Ns / Div To 50S / Div, Waveform Update Rate: 50, 000Waveforms / Sec, Acquisition Modes, Normal, Peak Detect Averaging, High Resolution Mode And Roll, Input Sensitivity : 1Mv / Div To 10V / Div, Vertical Control Knobs: Dedicated Controls Per Channel, Trigger Source: Ch 1, Ch 2, External, Trigger Types:Edge, Pulse Width & Runt, Math: Fft, Ch1-Ch2, Ch1+Ch2, Ch1*Ch2 Filter Automatic Measurements: 30 Or More Automatic Measurements Display Modes: Yt, Xy, Roll, Persistence Cursor Measurements: Both Amplitude And Time Cursors Available Training Signals: Interfaces Usb 2.0 Device Port And Usb 2.0 Host Port 6 Digit Trigger Frequency Counter, Inbuilt Lab Courseware With Software, 15 Horizontal Divisions For More Signals Capture, 5 Year Standard Warranty, 2 No Of 10X Passive Probes And Calibration Certificate , Pt-51 Board, Microcontroller : Atmel ( Now Microchip ) At89c5131a, Usb Powered And Programmable, 24Mhz Crystal Clock Generator, On Board 4 Leds And 4 Switches For Simple Programs, Dedicated Lcd Port, Type B Usb Connector, All Ports ( P0-P3 ) Accessible, Separate Headers For Serial Peripheral Interface ( Spi ) And Inter-Integratedcircuits ( I2c ) , Operating Temperature ( ? ) :- -20 To 80
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
26.
Defence #9230966 Technical Bid
Procurement Of 05 Lines Of Lllwr Spares , Cable Assy W3 , Cable Assy W9 , Cable Assy W-53 ( Cdu-Int Box Power ) , Grease Gun Mannual Lever Operated , Digital Earthing System , Fuse Monitor , Contactor , Contactor , Free-Wheeling Diode , Under Voltage Relays , Plc Interface Relay , Phase Sequence Monitor , Limit Switch , Level Switch , Key Switch , Switch , Selector Switch , Diffuse Reflection Sensor , Motor Protection Switch , Pulse Transformer C1000 , Bias Choke Coil , Vac-Ion Power Supply Board , Clamping Set , Soft Starter , Centrifugal Solenoid Blower , Centrifugal Tube Blower / Collector Blower , Axil Blower , Optical Encoder , Fan 40 Mm , Safety Valve , Vmebus Power Supply , Servo Drive Power Supply , Power Supply 24V4a , Power Supply 5V / 5A , Power Supply 24V / 3A , Power Supply 24V / 3A , Solenoid Power Supply , Power Supply12v / 15A , Power Supply 5V / 1A , Power Supply 12V / 1A , Bias Power Supply ( Dc ) , Power Supply 12V / 13A , Power Supply 5V4a / 15V2a , Power Supply 24V3a , Power Supply 8V3a / 8V3a , Power Supply , Bearing , Clamping Set , Flanges Brass Cover , Flanges Brass Choke , Circular , Noise Source , Single Channel Rotary Joint , Dual Channel Rotary Joint , Dual Loop Coupler , Variable Attenuator C Band , Flexible Waveguides , Booster Amplifier C Band , Arc Detector C Band , Rf-Switch Spst , Waveguide Power Divider , Dummy Load , Flexible Waveguides , Dual Channel Down Converter , Stalo Unit , Tx Channel Unit , Carrier Board Type A , Pinion , Power Brush Block , Signal Brush Block , Peak Current Detector Board , Switch Array Control Board 1000 , Grease Distributor , Measuring Interface , Booster Amplifier Control Board , Current Monitor Klystron , Gun Arc Detector Board , Status Monitoring Board X4k , Status Monitoring Board X5k , Power Supply 5V / 1A , Power Supply Board 18V / 12V 1A , Transmitter Oil Pump , Oil Level Sensor , Bus X5 Backplane , Bus X4 Backplane , Bus X3 Backplane , Trigger Timing Board , Current Monitor Klystron , Filament Interface Board , Slip Ring , Profibus Controller , Single Board Computer , Current Monitor Shunt Klystron , Voltage Monitor Klystron , Gdrx Board Set , Profibus Module , Binary Inout Module , Rs 232 Module , Carrier Board Type C , Can Module , Ssi Controller , Gdrx Transition Module , Carrier Board , Bias Interface Board , 2Nd Lo Unit , Sensor Board , Safety Plc , Step Attenuator , Digital Servo Drive , Driver Board , Ecl / Sin Convertor Unit , Heater , Bearing , Encoder Drive Incl Coupling , Power Supply 520W , Rf-Switch Spdt , Bearing , Servo Motors ( Comprising Qty 2 ) , Dehydrator , Klystron Cabinet ( Klystron Vkc8387, Magnet Vyw 8387, Oil Isolation Tank , Main Power Supply , Centrifugal Blower Systems For Radar , Wave Guide Switch , Receiver / Signal Processor , Itsg- Integrated Test Signal Generator For Sp Calibration , Seal Kit , Grease Pump , Switch Board 1000 Rev B , Power Supply 5V / 30A , Tab Tamsulosin 0.4Mg + Dutasteride 0.5 Mg , Tabnicoumalone2 Mg , Tabdicyclomine 20Mg + Paracetamol 325 Mg , Tab Sodium Valporate Cr 200Mg , Vitamin E 400Mg, Cap , Tab Nebivolol Hydrochloride 2.5Mg , Olopatadine Eye Drops , Tab Alfuzocin , Quitipine Sr 100Mg, Tab , Tab Antacid , Duloxetine 40 Mg, Tab , Azithromycin 1000Mg, Ornidazole 750Mg, Fluconazole 150Mg, Kit , Deionised Water 05 Ltr , Etophylline 231 Mg And Theophylline 69 Mg, Tab , Tabclidinium Bromide Chlodiazepoxide& Dicyclomine , Lamotrigine100 Mg , Tab Enalapril 5 Mg , Soft Neck Collar Size- M, L, Xl, Xxl , Prednisolone10 Mg Tab , Micropippette Tips 1-20 ?Lr , Pregnancy Test Strip , Dicyclominedrops , Sulphasalazine 1000Mg, Tab , Prazocin Xl 5Mg, Tab , Tab Chlomipramine 25 Mg , Terbinafine 1% Cream, Tube Of 10 Gms , Beclomethasone Valerate 0.05% W / W+ Phenylepherine Hydrochloride 0.1% W / W + Lignocain Hyddrochloride I.P 2.5% W / W In An Ointment Base , Printer Paper Roll1pkt Of 3 Roll 57Mm X 30 M , Syp B-Comlex , Vit C And Zinc , Tab Fluoxetine 20 Mg , Silver Sulphadiazine 0.20%, Chlorhexidine Gluconate 0.20%, Chlorocresol 0.12% W / W Cream Tube Of 15Gm , Tab Olmesartan 20 , Tongue Depressor Wooden , Tab Pioglitazone 30 Mg , Su Mag Jar Of 75 Gm ( Magnesium Sulfate ) , Feeding Bag , Ankle Support Size S, M, L, Xl , Tab Nitrofuradentin 100 Mg , Diclofenacdiethylamine, Linseed Oil, Methyl Salicylate &Menthol Spray , Tretinion Cream 0.05% , Syp Mefenamicacid +Pcm , Tab Hydrochlorthiazide12.5 Mg , Bacitracin Zinc, Neomycin Sulphate, Polymyxin B Sulphate , Powder , Omega 3 Fatty Acid, Cap , Betadine For Oral Use , Luliconazole Cream 1% W / W Tube Of 10G , Tab Mercaptopurine 50 Mg , Tab Olanzapine 5 Mg , Chlorhexidine Gluconate, Cetrimide, Gum Paint , Syp Deriphyllin Bott Of 100 Ml , Timolol 0.5% Eye Drops , Tabmetoprolol25mg , Ipratropium Bromide Solution Vial Of 10 Ml , Polyethylene Glycol 0.4% + Propylene Glycole 0.3% ( Systen Ultra ) Eye Drops , Melatonin 0.25 Mg Tablets , Evening Of Primrose Oil 500 Mg , Cap B Complex + Vit C + Zinc , Tab Sumitriptan50mg , Tab Rabeprazole20 , Tab Zinc , Tab Glicazide 80 Mg , Lidocaine / Lignocain ( 2% W / W ) +Chlorhexidine Gluconate ( 1% W / W ) + Metronidazole 1%Oint , Inj Methotraxate15mg , Wrist Band For Support , Arm Pouch , Plastic Urine Container , Vit D Drop 400Iu / 1 Ml , Oint Diltiazem , Tab Clonezpam 0.25 Mg , Beclomethasone 0.025% , Clotrimazole 1% , Lotion Bott Of 25Ml , Disposable Needle 26 1 / 2G , Tab Glimiperide 4Mg , Amlodepine 10Mg, Tab , Mosapride 5Mg, Tab , Aceclofenac 100Mg + Paracetamol 325Mg, Tab , Clomifene 50 Mg, Tab , Etoricoxib 60 Mg + Paracetamol 325 Mg , Cough Lozenges , Prochlorperazine Maleate 5 Mg , Tab Doxylamine+ Vit B6 ( Pyridoxin ) 40 , Acyclovir Skin Cream 5% Tube Of 5 Gm , Povidone Iodin Oint , Tab Haloperidol 0.25 Mg , Calamine + Diphenhydramine Hydrochloride Lotion , Tab Piracetam 400 Mg , Tab Biotin , Prednisolone Eye Drops 1 % , Tab Aceclofenac 100 Mg , Syp Haloperidol , Fluconazole Oint , Tab Isotretinion 20Mg , Tab Eltroxine 88Mcg , Nepafenac Eye Drop , Tab Amlodipine 2.5 Mg , Hypromellose ( Lacrigel ) Oint , Nitroglycerine, / Glyceryl Trinitrate 2.6Mg, Tab , Milk Of Magnesia 11.25 Mg, Liq Paraffin 3.75 Mg Suspension Bott Of 100Ml , Inj Vit B1, B6 , B12 And Calcium Pantothenate Amp Of 2 Ml ( Neurobion ) , Inj Vincristcin , Inj Depometrol , Hydroxyzine 10Mg, Tab , Tab Lacosamide 100 Mg , Sulphacetamide 20%Eye Drop , Inj Methylcobalamine , Syp Disodium Hydrogen Citrate ( Alkacitran ) Jar Of 5 Ltr , Dressing Medicated Waterproof , Suction Catheter , Moxifloxacin+Dexamethasone Eye Drop , Pp Crystals , Tess ( Triamcinolone Acetonide + Choline Salicylate ) Gel ( Ulsore, Mouth Ulcer ) , Isosorbide Mononitrate 10Mg, Tab , Corn Caps ( Pkt Of 4 ) , Inj Lignocain 2% , Chloromphenicoleye Apps , Dexamethasone 0.1% Eye Drops , Inj Haloperidol 5 Mg / Ml
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 7
27.
Defence #9230961 Technical Bid
Procurement Of 01 Line Of Iff Spares , Transistor Power Amplifier , Cable Assy W9 , Cable Assy W-53 (Cdu-Int Box Power) , Grease Gun Mannual Lever Operated , Digital Earthing System , Fuse Monitor , Contactor , Contactor , Free-Wheeling Diode , Under Voltage Relays , Plc Interface Relay , Phase Sequence Monitor , Limit Switch , Level Switch , Key Switch , Switch , Selector Switch , Diffuse Reflection Sensor , Motor Protection Switch , Pulse Transformer C1000 , Bias Choke Coil , Vac-Ion Power Supply Board , Clamping Set , Soft Starter , Centrifugal Solenoid Blower , Centrifugal Tube Blower/ Collector Blower , Axil Blower , Optical Encoder , Fan 40 Mm , Safety Valve , Vmebus Power Supply , Servo Drive Power Supply , Power Supply 24V4a , Power Supply 5V/5A , Power Supply 24V/3A , Power Supply 24V /3A , Solenoid Power Supply , Power Supply12v/15A , Power Supply 5V/1A , Power Supply 12V/1A , Bias Power Supply(Dc) , Power Supply 12V/13A , Power Supply 5V4a/15V2a , Power Supply 24V3a , Power Supply 8V3a/8V3a , Power Supply , Bearing , Clamping Set , Flanges Brass Cover , Flanges Brass Choke , Circular , Noise Source , Single Channel Rotary Joint , Dual Channel Rotary Joint , Dual Loop Coupler , Variable Attenuator C Band , Flexible Waveguides , Booster Amplifier C Band , Arc Detector C Band , Rf-Switch Spst , Waveguide Power Divider , Dummy Load , Flexible Waveguides , Dual Channel Down Converter , Stalo Unit , Tx Channel Unit , Carrier Board Type A , Pinion , Power Brush Block , Signal Brush Block , Peak Current Detector Board , Switch Array Control Board 1000 , Grease Distributor , Measuring Interface , Booster Amplifier Control Board , Current Monitor Klystron , Gun Arc Detector Board , Status Monitoring Board X4k , Status Monitoring Board X5k , Power Supply 5V/1A , Power Supply Board 18V/12V 1A , Transmitter Oil Pump , Oil Level Sensor , Bus X5 Backplane , Bus X4 Backplane , Bus X3 Backplane , Trigger Timing Board , Current Monitor Klystron , Filament Interface Board , Slip Ring , Profibus Controller , Single Board Computer , Current Monitor Shunt Klystron , Voltage Monitor Klystron , Gdrx Board Set , Profibus Module , Binary Inout Module , Rs 232 Module , Carrier Board Type C , Can Module , Ssi Controller , Gdrx Transition Module , Carrier Board , Bias Interface Board , 2Nd Lo Unit , Sensor Board , Safety Plc , Step Attenuator , Digital Servo Drive , Driver Board , Ecl/Sin Convertor Unit , Heater , Bearing , Encoder Drive Incl Coupling , Power Supply 520W , Rf-Switch Spdt , Bearing , Servo Motors (Comprising Qty 2) , Dehydrator , Klystron Cabinet (Klystron Vkc8387, Magnet Vyw 8387, Oil Isolation Tank , Main Power Supply , Centrifugal Blower Systems For Radar , Wave Guide Switch , Receiver / Signal Processor , Itsg- Integrated Test Signal Generator For Sp Calibration , Seal Kit , Grease Pump , Switch Board 1000 Rev B , Power Supply 5V/30A , Tab Tamsulosin 0.4Mg + Dutasteride 0.5 Mg , Tabnicoumalone2 Mg , Tabdicyclomine 20Mg + Paracetamol 325 Mg , Tab Sodium Valporate Cr 200Mg , Vitamin E 400Mg, Cap , Tab Nebivolol Hydrochloride 2.5Mg , Olopatadine Eye Drops , Tab Alfuzocin , Quitipine Sr 100Mg, Tab , Tab Antacid , Duloxetine 40 Mg, Tab , Azithromycin 1000Mg, Ornidazole 750Mg, Fluconazole 150Mg, Kit , Deionised Water 05 Ltr , Etophylline 231 Mg And Theophylline 69 Mg, Tab , Tabclidinium Bromide Chlodiazepoxide& Dicyclomine , Lamotrigine100 Mg , Tab Enalapril 5 Mg , Soft Neck Collar Size- M, L, Xl, Xxl , Prednisolone10 Mg Tab , Micropippette Tips 1-20 ?Lr , Pregnancy Test Strip , Dicyclominedrops , Sulphasalazine 1000Mg, Tab , Prazocin Xl 5Mg, Tab , Tab Chlomipramine 25 Mg , Terbinafine 1% Cream, Tube Of 10 Gms , Beclomethasone Valerate 0.05% W/W+ Phenylepherine Hydrochloride 0.1% W/W + Lignocain Hyddrochloride I.P 2.5% W/W In An Ointment Base , Printer Paper Roll1pkt Of 3 Roll 57Mm X 30 M , Syp B-Comlex , Vit C And Zinc , Tab Fluoxetine 20 Mg , Silver Sulphadiazine 0.20%, Chlorhexidine Gluconate 0.20%, Chlorocresol 0.12% W/W Cream Tube Of 15Gm , Tab Olmesartan 20 , Tongue Depressor Wooden , Tab Pioglitazone 30 Mg , Su Mag Jar Of 75 Gm (Magnesium Sulfate) , Feeding Bag , Ankle Support Size S, M, L, Xl , Tab Nitrofuradentin 100 Mg , Diclofenacdiethylamine,Linseed Oil,Methyl Salicylate &Menthol Spray , Tretinion Cream 0.05% , Syp Mefenamicacid +Pcm , Tab Hydrochlorthiazide12.5 Mg , Bacitracin Zinc, Neomycin Sulphate, Polymyxin B Sulphate , Powder , Omega 3 Fatty Acid, Cap , Betadine For Oral Use , Luliconazole Cream 1% W/W Tube Of 10G , Tab Mercaptopurine 50 Mg , Tab Olanzapine 5 Mg , Chlorhexidine Gluconate, Cetrimide, Gum Paint , Syp Deriphyllin Bott Of 100 Ml , Timolol 0.5% Eye Drops , Tabmetoprolol25mg , Ipratropium Bromide Solution Vial Of 10 Ml , Polyethylene Glycol 0.4% + Propylene Glycole 0.3%(Systen Ultra) Eye Drops , Melatonin 0.25 Mg Tablets , Evening Of Primrose Oil 500 Mg , Cap B Complex + Vit C + Zinc , Tab Sumitriptan50mg , Tab Rabeprazole20 , Tab Zinc , Tab Glicazide 80 Mg , Lidocaine/Lignocain(2% W/W) +Chlorhexidine Gluconate(1% W/W)+ Metronidazole 1%Oint , Inj Methotraxate15mg , Wrist Band For Support , Arm Pouch , Plastic Urine Container , Vit D Drop 400Iu/1 Ml , Oint Diltiazem , Tab Clonezpam 0.25 Mg , Beclomethasone 0.025% , Clotrimazole 1% , Lotion Bott Of 25Ml , Disposable Needle 26 1/2G , Tab Glimiperide 4Mg , Amlodepine 10Mg, Tab , Mosapride 5Mg, Tab , Aceclofenac 100Mg + Paracetamol 325Mg, Tab , Clomifene 50 Mg, Tab , Etoricoxib 60 Mg + Paracetamol 325 Mg , Cough Lozenges , Prochlorperazine Maleate 5 Mg , Tab Doxylamine+ Vit B6 (Pyridoxin) 40 , Acyclovir Skin Cream 5% Tube Of 5 Gm , Povidone Iodin Oint , Tab Haloperidol 0.25 Mg , Calamine + Diphenhydramine Hydrochloride Lotion , Tab Piracetam 400 Mg , Tab Biotin , Prednisolone Eye Drops 1 % , Tab Aceclofenac 100 Mg , Syp Haloperidol , Fluconazole Oint , Tab Isotretinion 20Mg , Tab Eltroxine 88Mcg , Nepafenac Eye Drop , Tab Amlodipine 2.5 Mg , Hypromellose (Lacrigel) Oint , Nitroglycerine,/ Glyceryl Trinitrate 2.6Mg, Tab , Milk Of Magnesia 11.25 Mg, Liq Paraffin 3.75 Mg Suspension Bott Of 100Ml , Inj Vit B1, B6 ,B12 And Calcium Pantothenate Amp Of 2 Ml (Neurobion) , Inj Vincristcin , Inj Depometrol , Hydroxyzine 10Mg, Tab , Tab Lacosamide 100 Mg , Sulphacetamide 20%Eye Drop , Inj Methylcobalamine , Syp Disodium Hydrogen Citrate (Alkacitran) Jar Of 5 Ltr , Dressing Medicated Waterproof , Suction Catheter , Moxifloxacin+Dexamethasone Eye Drop , Pp Crystals , Tess(Triamcinolone Acetonide + Choline Salicylate) Gel(Ulsore,Mouth Ulcer) , Isosorbide Mononitrate 10Mg, Tab , Corn Caps (Pkt Of 4) , Inj Lignocain 2% , Chloromphenicoleye Apps , Dexamethasone 0.1% Eye Drops , Inj Haloperidol 5 Mg/Ml
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
28.
Defence #9230952 Technical Bid
For Procurement Of One Line Of Adges Test Equipment , Switchedfilter 22-2 , Pwa Processor (Af171000269278) , Potentiometer , Blower Motor Capacitor , Fuse 2,5At , Fuse Monitor , Contactor , Contactor , Free-Wheeling Diode , Under Voltage Relays , Plc Interface Relay , Phase Sequence Monitor , Limit Switch , Level Switch , Key Switch , Switch , Selector Switch , Diffuse Reflection Sensor , Motor Protection Switch , Pulse Transformer C1000 , Bias Choke Coil , Vac-Ion Power Supply Board , Clamping Set , Soft Starter , Centrifugal Solenoid Blower , Centrifugal Tube Blower/ Collector Blower , Axil Blower , Optical Encoder , Fan 40 Mm , Safety Valve , Vmebus Power Supply , Servo Drive Power Supply , Power Supply 24V4a , Power Supply 5V/5A , Power Supply 24V/3A , Power Supply 24V /3A , Solenoid Power Supply , Power Supply12v/15A , Power Supply 5V/1A , Power Supply 12V/1A , Bias Power Supply(Dc) , Power Supply 12V/13A , Power Supply 5V4a/15V2a , Power Supply 24V3a , Power Supply 8V3a/8V3a , Power Supply , Bearing , Clamping Set , Flanges Brass Cover , Flanges Brass Choke , Circular , Noise Source , Single Channel Rotary Joint , Dual Channel Rotary Joint , Dual Loop Coupler , Variable Attenuator C Band , Flexible Waveguides , Booster Amplifier C Band , Arc Detector C Band , Rf-Switch Spst , Waveguide Power Divider , Dummy Load , Flexible Waveguides , Dual Channel Down Converter , Stalo Unit , Tx Channel Unit , Carrier Board Type A , Pinion , Power Brush Block , Signal Brush Block , Peak Current Detector Board , Switch Array Control Board 1000 , Grease Distributor , Measuring Interface , Booster Amplifier Control Board , Current Monitor Klystron , Gun Arc Detector Board , Status Monitoring Board X4k , Status Monitoring Board X5k , Power Supply 5V/1A , Power Supply Board 18V/12V 1A , Transmitter Oil Pump , Oil Level Sensor , Bus X5 Backplane , Bus X4 Backplane , Bus X3 Backplane , Trigger Timing Board , Current Monitor Klystron , Filament Interface Board , Slip Ring , Profibus Controller , Single Board Computer , Current Monitor Shunt Klystron , Voltage Monitor Klystron , Gdrx Board Set , Profibus Module , Binary Inout Module , Rs 232 Module , Carrier Board Type C , Can Module , Ssi Controller , Gdrx Transition Module , Carrier Board , Bias Interface Board , 2Nd Lo Unit , Sensor Board , Safety Plc , Step Attenuator , Digital Servo Drive , Driver Board , Ecl/Sin Convertor Unit , Heater , Bearing , Encoder Drive Incl Coupling , Power Supply 520W , Rf-Switch Spdt , Bearing , Servo Motors (Comprising Qty 2) , Dehydrator , Klystron Cabinet (Klystron Vkc8387, Magnet Vyw 8387, Oil Isolation Tank , Main Power Supply , Centrifugal Blower Systems For Radar , Wave Guide Switch , Receiver / Signal Processor , Itsg- Integrated Test Signal Generator For Sp Calibration , Seal Kit , Grease Pump , Switch Board 1000 Rev B , Power Supply 5V/30A , Tab Tamsulosin 0.4Mg + Dutasteride 0.5 Mg , Tabnicoumalone2 Mg , Tabdicyclomine 20Mg + Paracetamol 325 Mg , Tab Sodium Valporate Cr 200Mg , Vitamin E 400Mg, Cap , Tab Nebivolol Hydrochloride 2.5Mg , Olopatadine Eye Drops , Tab Alfuzocin , Quitipine Sr 100Mg, Tab , Tab Antacid , Duloxetine 40 Mg, Tab , Azithromycin 1000Mg, Ornidazole 750Mg, Fluconazole 150Mg, Kit , Deionised Water 05 Ltr , Etophylline 231 Mg And Theophylline 69 Mg, Tab , Tabclidinium Bromide Chlodiazepoxide& Dicyclomine , Lamotrigine100 Mg , Tab Enalapril 5 Mg , Soft Neck Collar Size- M, L, Xl, Xxl , Prednisolone10 Mg Tab , Micropippette Tips 1-20 ?Lr , Pregnancy Test Strip , Dicyclominedrops , Sulphasalazine 1000Mg, Tab , Prazocin Xl 5Mg, Tab , Tab Chlomipramine 25 Mg , Terbinafine 1% Cream, Tube Of 10 Gms , Beclomethasone Valerate 0.05% W/W+ Phenylepherine Hydrochloride 0.1% W/W + Lignocain Hyddrochloride I.P 2.5% W/W In An Ointment Base , Printer Paper Roll1pkt Of 3 Roll 57Mm X 30 M , Syp B-Comlex , Vit C And Zinc , Tab Fluoxetine 20 Mg , Silver Sulphadiazine 0.20%, Chlorhexidine Gluconate 0.20%, Chlorocresol 0.12% W/W Cream Tube Of 15Gm , Tab Olmesartan 20 , Tongue Depressor Wooden , Tab Pioglitazone 30 Mg , Su Mag Jar Of 75 Gm (Magnesium Sulfate) , Feeding Bag , Ankle Support Size S, M, L, Xl , Tab Nitrofuradentin 100 Mg , Diclofenacdiethylamine,Linseed Oil,Methyl Salicylate &Menthol Spray , Tretinion Cream 0.05% , Syp Mefenamicacid +Pcm , Tab Hydrochlorthiazide12.5 Mg , Bacitracin Zinc, Neomycin Sulphate, Polymyxin B Sulphate , Powder , Omega 3 Fatty Acid, Cap , Betadine For Oral Use , Luliconazole Cream 1% W/W Tube Of 10G , Tab Mercaptopurine 50 Mg , Tab Olanzapine 5 Mg , Chlorhexidine Gluconate, Cetrimide, Gum Paint , Syp Deriphyllin Bott Of 100 Ml , Timolol 0.5% Eye Drops , Tabmetoprolol25mg , Ipratropium Bromide Solution Vial Of 10 Ml , Polyethylene Glycol 0.4% + Propylene Glycole 0.3%(Systen Ultra) Eye Drops , Melatonin 0.25 Mg Tablets , Evening Of Primrose Oil 500 Mg , Cap B Complex + Vit C + Zinc , Tab Sumitriptan50mg , Tab Rabeprazole20 , Tab Zinc , Tab Glicazide 80 Mg , Lidocaine/Lignocain(2% W/W) +Chlorhexidine Gluconate(1% W/W)+ Metronidazole 1%Oint , Inj Methotraxate15mg , Wrist Band For Support , Arm Pouch , Plastic Urine Container , Vit D Drop 400Iu/1 Ml , Oint Diltiazem , Tab Clonezpam 0.25 Mg , Beclomethasone 0.025% , Clotrimazole 1% , Lotion Bott Of 25Ml , Disposable Needle 26 1/2G , Tab Glimiperide 4Mg , Amlodepine 10Mg, Tab , Mosapride 5Mg, Tab , Aceclofenac 100Mg + Paracetamol 325Mg, Tab , Clomifene 50 Mg, Tab , Etoricoxib 60 Mg + Paracetamol 325 Mg , Cough Lozenges , Prochlorperazine Maleate 5 Mg , Tab Doxylamine+ Vit B6 (Pyridoxin) 40 , Acyclovir Skin Cream 5% Tube Of 5 Gm , Povidone Iodin Oint , Tab Haloperidol 0.25 Mg , Calamine + Diphenhydramine Hydrochloride Lotion , Tab Piracetam 400 Mg , Tab Biotin , Prednisolone Eye Drops 1 % , Tab Aceclofenac 100 Mg , Syp Haloperidol , Fluconazole Oint , Tab Isotretinion 20Mg , Tab Eltroxine 88Mcg , Nepafenac Eye Drop , Tab Amlodipine 2.5 Mg , Hypromellose (Lacrigel) Oint , Nitroglycerine,/ Glyceryl Trinitrate 2.6Mg, Tab , Milk Of Magnesia 11.25 Mg, Liq Paraffin 3.75 Mg Suspension Bott Of 100Ml , Inj Vit B1, B6 ,B12 And Calcium Pantothenate Amp Of 2 Ml (Neurobion) , Inj Vincristcin , Inj Depometrol , Hydroxyzine 10Mg, Tab , Tab Lacosamide 100 Mg , Sulphacetamide 20%Eye Drop , Inj Methylcobalamine , Syp Disodium Hydrogen Citrate (Alkacitran) Jar Of 5 Ltr , Dressing Medicated Waterproof , Suction Catheter , Moxifloxacin+Dexamethasone Eye Drop , Pp Crystals , Tess(Triamcinolone Acetonide + Choline Salicylate) Gel(Ulsore,Mouth Ulcer) , Isosorbide Mononitrate 10Mg, Tab , Corn Caps (Pkt Of 4) , Inj Lignocain 2% , Chloromphenicoleye Apps , Dexamethasone 0.1% Eye Drops , Inj Haloperidol 5 Mg/Ml
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 7
29.
Defence #9230902 Technical Bid
Procurement Of Three Lines Of Mpr , Cable Assy F / O Wext03 , Fiber Optics Loss Test Kit , Sealant Silicon Rubber Adhesive Pas , Std Inductor 10H Sl 16851 , Inductor 1H 51 20106 , Std Inductor 100Uh , Contactor , Contactor , Free-Wheeling Diode , Under Voltage Relays , Plc Interface Relay , Phase Sequence Monitor , Limit Switch , Level Switch , Key Switch , Switch , Selector Switch , Diffuse Reflection Sensor , Motor Protection Switch , Pulse Transformer C1000 , Bias Choke Coil , Vac-Ion Power Supply Board , Clamping Set , Soft Starter , Centrifugal Solenoid Blower , Centrifugal Tube Blower / Collector Blower , Axil Blower , Optical Encoder , Fan 40 Mm , Safety Valve , Vmebus Power Supply , Servo Drive Power Supply , Power Supply 24V4a , Power Supply 5V / 5A , Power Supply 24V / 3A , Power Supply 24V / 3A , Solenoid Power Supply , Power Supply12v / 15A , Power Supply 5V / 1A , Power Supply 12V / 1A , Bias Power Supply ( Dc ) , Power Supply 12V / 13A , Power Supply 5V4a / 15V2a , Power Supply 24V3a , Power Supply 8V3a / 8V3a , Power Supply , Bearing , Clamping Set , Flanges Brass Cover , Flanges Brass Choke , Circular , Noise Source , Single Channel Rotary Joint , Dual Channel Rotary Joint , Dual Loop Coupler , Variable Attenuator C Band , Flexible Waveguides , Booster Amplifier C Band , Arc Detector C Band , Rf-Switch Spst , Waveguide Power Divider , Dummy Load , Flexible Waveguides , Dual Channel Down Converter , Stalo Unit , Tx Channel Unit , Carrier Board Type A , Pinion , Power Brush Block , Signal Brush Block , Peak Current Detector Board , Switch Array Control Board 1000 , Grease Distributor , Measuring Interface , Booster Amplifier Control Board , Current Monitor Klystron , Gun Arc Detector Board , Status Monitoring Board X4k , Status Monitoring Board X5k , Power Supply 5V / 1A , Power Supply Board 18V / 12V 1A , Transmitter Oil Pump , Oil Level Sensor , Bus X5 Backplane , Bus X4 Backplane , Bus X3 Backplane , Trigger Timing Board , Current Monitor Klystron , Filament Interface Board , Slip Ring , Profibus Controller , Single Board Computer , Current Monitor Shunt Klystron , Voltage Monitor Klystron , Gdrx Board Set , Profibus Module , Binary Inout Module , Rs 232 Module , Carrier Board Type C , Can Module , Ssi Controller , Gdrx Transition Module , Carrier Board , Bias Interface Board , 2Nd Lo Unit , Sensor Board , Safety Plc , Step Attenuator , Digital Servo Drive , Driver Board , Ecl / Sin Convertor Unit , Heater , Bearing , Encoder Drive Incl Coupling , Power Supply 520W , Rf-Switch Spdt , Bearing , Servo Motors ( Comprising Qty 2 ) , Dehydrator , Klystron Cabinet ( Klystron Vkc8387, Magnet Vyw 8387, Oil Isolation Tank , Main Power Supply , Centrifugal Blower Systems For Radar , Wave Guide Switch , Receiver / Signal Processor , Itsg- Integrated Test Signal Generator For Sp Calibration , Seal Kit , Grease Pump , Switch Board 1000 Rev B , Power Supply 5V / 30A , Tab Tamsulosin 0.4Mg + Dutasteride 0.5 Mg , Tabnicoumalone2 Mg , Tabdicyclomine 20Mg + Paracetamol 325 Mg , Tab Sodium Valporate Cr 200Mg , Vitamin E 400Mg, Cap , Tab Nebivolol Hydrochloride 2.5Mg , Olopatadine Eye Drops , Tab Alfuzocin , Quitipine Sr 100Mg, Tab , Tab Antacid , Duloxetine 40 Mg, Tab , Azithromycin 1000Mg, Ornidazole 750Mg, Fluconazole 150Mg, Kit , Deionised Water 05 Ltr , Etophylline 231 Mg And Theophylline 69 Mg, Tab , Tabclidinium Bromide Chlodiazepoxide& Dicyclomine , Lamotrigine100 Mg , Tab Enalapril 5 Mg , Soft Neck Collar Size- M, L, Xl, Xxl , Prednisolone10 Mg Tab , Micropippette Tips 1-20 ?Lr , Pregnancy Test Strip , Dicyclominedrops , Sulphasalazine 1000Mg, Tab , Prazocin Xl 5Mg, Tab , Tab Chlomipramine 25 Mg , Terbinafine 1% Cream, Tube Of 10 Gms , Beclomethasone Valerate 0.05% W / W+ Phenylepherine Hydrochloride 0.1% W / W + Lignocain Hyddrochloride I.P 2.5% W / W In An Ointment Base , Printer Paper Roll1pkt Of 3 Roll 57Mm X 30 M , Syp B-Comlex , Vit C And Zinc , Tab Fluoxetine 20 Mg , Silver Sulphadiazine 0.20%, Chlorhexidine Gluconate 0.20%, Chlorocresol 0.12% W / W Cream Tube Of 15Gm , Tab Olmesartan 20 , Tongue Depressor Wooden , Tab Pioglitazone 30 Mg , Su Mag Jar Of 75 Gm ( Magnesium Sulfate ) , Feeding Bag , Ankle Support Size S, M, L, Xl , Tab Nitrofuradentin 100 Mg , Diclofenacdiethylamine, Linseed Oil, Methyl Salicylate &Menthol Spray , Tretinion Cream 0.05% , Syp Mefenamicacid +Pcm , Tab Hydrochlorthiazide12.5 Mg , Bacitracin Zinc, Neomycin Sulphate, Polymyxin B Sulphate , Powder , Omega 3 Fatty Acid, Cap , Betadine For Oral Use , Luliconazole Cream 1% W / W Tube Of 10G , Tab Mercaptopurine 50 Mg , Tab Olanzapine 5 Mg , Chlorhexidine Gluconate, Cetrimide, Gum Paint , Syp Deriphyllin Bott Of 100 Ml , Timolol 0.5% Eye Drops , Tabmetoprolol25mg , Ipratropium Bromide Solution Vial Of 10 Ml , Polyethylene Glycol 0.4% + Propylene Glycole 0.3% ( Systen Ultra ) Eye Drops , Melatonin 0.25 Mg Tablets , Evening Of Primrose Oil 500 Mg , Cap B Complex + Vit C + Zinc , Tab Sumitriptan50mg , Tab Rabeprazole20 , Tab Zinc , Tab Glicazide 80 Mg , Lidocaine / Lignocain ( 2% W / W ) +Chlorhexidine Gluconate ( 1% W / W ) + Metronidazole 1%Oint , Inj Methotraxate15mg , Wrist Band For Support , Arm Pouch , Plastic Urine Container , Vit D Drop 400Iu / 1 Ml , Oint Diltiazem , Tab Clonezpam 0.25 Mg , Beclomethasone 0.025% , Clotrimazole 1% , Lotion Bott Of 25Ml , Disposable Needle 26 1 / 2G , Tab Glimiperide 4Mg , Amlodepine 10Mg, Tab , Mosapride 5Mg, Tab , Aceclofenac 100Mg + Paracetamol 325Mg, Tab , Clomifene 50 Mg, Tab , Etoricoxib 60 Mg + Paracetamol 325 Mg , Cough Lozenges , Prochlorperazine Maleate 5 Mg , Tab Doxylamine+ Vit B6 ( Pyridoxin ) 40 , Acyclovir Skin Cream 5% Tube Of 5 Gm , Povidone Iodin Oint , Tab Haloperidol 0.25 Mg , Calamine + Diphenhydramine Hydrochloride Lotion , Tab Piracetam 400 Mg , Tab Biotin , Prednisolone Eye Drops 1 % , Tab Aceclofenac 100 Mg , Syp Haloperidol , Fluconazole Oint , Tab Isotretinion 20Mg , Tab Eltroxine 88Mcg , Nepafenac Eye Drop , Tab Amlodipine 2.5 Mg , Hypromellose ( Lacrigel ) Oint , Nitroglycerine, / Glyceryl Trinitrate 2.6Mg, Tab , Milk Of Magnesia 11.25 Mg, Liq Paraffin 3.75 Mg Suspension Bott Of 100Ml , Inj Vit B1, B6 , B12 And Calcium Pantothenate Amp Of 2 Ml ( Neurobion ) , Inj Vincristcin , Inj Depometrol , Hydroxyzine 10Mg, Tab , Tab Lacosamide 100 Mg , Sulphacetamide 20%Eye Drop , Inj Methylcobalamine , Syp Disodium Hydrogen Citrate ( Alkacitran ) Jar Of 5 Ltr , Dressing Medicated Waterproof , Suction Catheter , Moxifloxacin+Dexamethasone Eye Drop , Pp Crystals , Tess ( Triamcinolone Acetonide + Choline Salicylate ) Gel ( Ulsore, Mouth Ulcer ) , Isosorbide Mononitrate 10Mg, Tab , Corn Caps ( Pkt Of 4 ) , Inj Lignocain 2% , Chloromphenicoleye Apps , Dexamethasone 0.1% Eye Drops , Inj Haloperidol 5 Mg / Ml
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 6
30.
Defence #9214716 Technical Bid
Procurement Of Two Lines Of Adges Thd Radar , Potentio Meteerlin Cer Type , Transitstor 92Dt2 , Potentiometer , Blower Motor Capacitor , Fuse 2,5At , Fuse Monitor , Contactor , Contactor , Free-Wheeling Diode , Under Voltage Relays , Plc Interface Relay , Phase Sequence Monitor , Limit Switch , Level Switch , Key Switch , Switch , Selector Switch , Diffuse Reflection Sensor , Motor Protection Switch , Pulse Transformer C1000 , Bias Choke Coil , Vac-Ion Power Supply Board , Clamping Set , Soft Starter , Centrifugal Solenoid Blower , Centrifugal Tube Blower/ Collector Blower , Axil Blower , Optical Encoder , Fan 40 Mm , Safety Valve , Vmebus Power Supply , Servo Drive Power Supply , Power Supply 24V4a , Power Supply 5V/5A , Power Supply 24V/3A , Power Supply 24V /3A , Solenoid Power Supply , Power Supply12v/15A , Power Supply 5V/1A , Power Supply 12V/1A , Bias Power Supply(Dc) , Power Supply 12V/13A , Power Supply 5V4a/15V2a , Power Supply 24V3a , Power Supply 8V3a/8V3a , Power Supply , Bearing , Clamping Set , Flanges Brass Cover , Flanges Brass Choke , Circular , Noise Source , Single Channel Rotary Joint , Dual Channel Rotary Joint , Dual Loop Coupler , Variable Attenuator C Band , Flexible Waveguides , Booster Amplifier C Band , Arc Detector C Band , Rf-Switch Spst , Waveguide Power Divider , Dummy Load , Flexible Waveguides , Dual Channel Down Converter , Stalo Unit , Tx Channel Unit , Carrier Board Type A , Pinion , Power Brush Block , Signal Brush Block , Peak Current Detector Board , Switch Array Control Board 1000 , Grease Distributor , Measuring Interface , Booster Amplifier Control Board , Current Monitor Klystron , Gun Arc Detector Board , Status Monitoring Board X4k , Status Monitoring Board X5k , Power Supply 5V/1A , Power Supply Board 18V/12V 1A , Transmitter Oil Pump , Oil Level Sensor , Bus X5 Backplane , Bus X4 Backplane , Bus X3 Backplane , Trigger Timing Board , Current Monitor Klystron , Filament Interface Board , Slip Ring , Profibus Controller , Single Board Computer , Current Monitor Shunt Klystron , Voltage Monitor Klystron , Gdrx Board Set , Profibus Module , Binary Inout Module , Rs 232 Module , Carrier Board Type C , Can Module , Ssi Controller , Gdrx Transition Module , Carrier Board , Bias Interface Board , 2Nd Lo Unit , Sensor Board , Safety Plc , Step Attenuator , Digital Servo Drive , Driver Board , Ecl/Sin Convertor Unit , Heater , Bearing , Encoder Drive Incl Coupling , Power Supply 520W , Rf-Switch Spdt , Bearing , Servo Motors (Comprising Qty 2) , Dehydrator , Klystron Cabinet (Klystron Vkc8387, Magnet Vyw 8387, Oil Isolation Tank , Main Power Supply , Centrifugal Blower Systems For Radar , Wave Guide Switch , Receiver / Signal Processor , Itsg- Integrated Test Signal Generator For Sp Calibration , Seal Kit , Grease Pump , Switch Board 1000 Rev B , Power Supply 5V/30A , Tab Tamsulosin 0.4Mg + Dutasteride 0.5 Mg , Tabnicoumalone2 Mg , Tabdicyclomine 20Mg + Paracetamol 325 Mg , Tab Sodium Valporate Cr 200Mg , Vitamin E 400Mg, Cap , Tab Nebivolol Hydrochloride 2.5Mg , Olopatadine Eye Drops , Tab Alfuzocin , Quitipine Sr 100Mg, Tab , Tab Antacid , Duloxetine 40 Mg, Tab , Azithromycin 1000Mg, Ornidazole 750Mg, Fluconazole 150Mg, Kit , Deionised Water 05 Ltr , Etophylline 231 Mg And Theophylline 69 Mg, Tab , Tabclidinium Bromide Chlodiazepoxide& Dicyclomine , Lamotrigine100 Mg , Tab Enalapril 5 Mg , Soft Neck Collar Size- M, L, Xl, Xxl , Prednisolone10 Mg Tab , Micropippette Tips 1-20 ?Lr , Pregnancy Test Strip , Dicyclominedrops , Sulphasalazine 1000Mg, Tab , Prazocin Xl 5Mg, Tab , Tab Chlomipramine 25 Mg , Terbinafine 1% Cream, Tube Of 10 Gms , Beclomethasone Valerate 0.05% W/W+ Phenylepherine Hydrochloride 0.1% W/W + Lignocain Hyddrochloride I.P 2.5% W/W In An Ointment Base , Printer Paper Roll1pkt Of 3 Roll 57Mm X 30 M , Syp B-Comlex , Vit C And Zinc , Tab Fluoxetine 20 Mg , Silver Sulphadiazine 0.20%, Chlorhexidine Gluconate 0.20%, Chlorocresol 0.12% W/W Cream Tube Of 15Gm , Tab Olmesartan 20 , Tongue Depressor Wooden , Tab Pioglitazone 30 Mg , Su Mag Jar Of 75 Gm (Magnesium Sulfate) , Feeding Bag , Ankle Support Size S, M, L, Xl , Tab Nitrofuradentin 100 Mg , Diclofenacdiethylamine,Linseed Oil,Methyl Salicylate &Menthol Spray , Tretinion Cream 0.05% , Syp Mefenamicacid +Pcm , Tab Hydrochlorthiazide12.5 Mg , Bacitracin Zinc, Neomycin Sulphate, Polymyxin B Sulphate , Powder , Omega 3 Fatty Acid, Cap , Betadine For Oral Use , Luliconazole Cream 1% W/W Tube Of 10G , Tab Mercaptopurine 50 Mg , Tab Olanzapine 5 Mg , Chlorhexidine Gluconate, Cetrimide, Gum Paint , Syp Deriphyllin Bott Of 100 Ml , Timolol 0.5% Eye Drops , Tabmetoprolol25mg , Ipratropium Bromide Solution Vial Of 10 Ml , Polyethylene Glycol 0.4% + Propylene Glycole 0.3%(Systen Ultra) Eye Drops , Melatonin 0.25 Mg Tablets , Evening Of Primrose Oil 500 Mg , Cap B Complex + Vit C + Zinc , Tab Sumitriptan50mg , Tab Rabeprazole20 , Tab Zinc , Tab Glicazide 80 Mg , Lidocaine/Lignocain(2% W/W) +Chlorhexidine Gluconate(1% W/W)+ Metronidazole 1%Oint , Inj Methotraxate15mg , Wrist Band For Support , Arm Pouch , Plastic Urine Container , Vit D Drop 400Iu/1 Ml , Oint Diltiazem , Tab Clonezpam 0.25 Mg , Beclomethasone 0.025% , Clotrimazole 1% , Lotion Bott Of 25Ml , Disposable Needle 26 1/2G , Tab Glimiperide 4Mg , Amlodepine 10Mg, Tab , Mosapride 5Mg, Tab , Aceclofenac 100Mg + Paracetamol 325Mg, Tab , Clomifene 50 Mg, Tab , Etoricoxib 60 Mg + Paracetamol 325 Mg , Cough Lozenges , Prochlorperazine Maleate 5 Mg , Tab Doxylamine+ Vit B6 (Pyridoxin) 40 , Acyclovir Skin Cream 5% Tube Of 5 Gm , Povidone Iodin Oint , Tab Haloperidol 0.25 Mg , Calamine + Diphenhydramine Hydrochloride Lotion , Tab Piracetam 400 Mg , Tab Biotin , Prednisolone Eye Drops 1 % , Tab Aceclofenac 100 Mg , Syp Haloperidol , Fluconazole Oint , Tab Isotretinion 20Mg , Tab Eltroxine 88Mcg , Nepafenac Eye Drop , Tab Amlodipine 2.5 Mg , Hypromellose (Lacrigel) Oint , Nitroglycerine,/ Glyceryl Trinitrate 2.6Mg, Tab , Milk Of Magnesia 11.25 Mg, Liq Paraffin 3.75 Mg Suspension Bott Of 100Ml , Inj Vit B1, B6 ,B12 And Calcium Pantothenate Amp Of 2 Ml (Neurobion) , Inj Vincristcin , Inj Depometrol , Hydroxyzine 10Mg, Tab , Tab Lacosamide 100 Mg , Sulphacetamide 20%Eye Drop , Inj Methylcobalamine , Syp Disodium Hydrogen Citrate (Alkacitran) Jar Of 5 Ltr , Dressing Medicated Waterproof , Suction Catheter , Moxifloxacin+Dexamethasone Eye Drop , Pp Crystals , Tess(Triamcinolone Acetonide + Choline Salicylate) Gel(Ulsore,Mouth Ulcer) , Isosorbide Mononitrate 10Mg, Tab , Corn Caps (Pkt Of 4) , Inj Lignocain 2% , Chloromphenicoleye Apps , Dexamethasone 0.1% Eye Drops , Inj Haloperidol 5 Mg/Ml
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
31.
Defence #9207595 Technical Bid
Procurement Of 129 Lines Of Dwr Met. , Fan 80Mm , Solenoid C Band , Potentiometer , Blower Motor Capacitor , Fuse 2,5At , Fuse Monitor , Contactor , Contactor , Free-Wheeling Diode , Under Voltage Relays , Plc Interface Relay , Phase Sequence Monitor , Limit Switch , Level Switch , Key Switch , Switch , Selector Switch , Diffuse Reflection Sensor , Motor Protection Switch , Pulse Transformer C1000 , Bias Choke Coil , Vac-Ion Power Supply Board , Clamping Set , Soft Starter , Centrifugal Solenoid Blower , Centrifugal Tube Blower/ Collector Blower , Axil Blower , Optical Encoder , Fan 40 Mm , Safety Valve , Vmebus Power Supply , Servo Drive Power Supply , Power Supply 24V4a , Power Supply 5V/5A , Power Supply 24V/3A , Power Supply 24V /3A , Solenoid Power Supply , Power Supply12v/15A , Power Supply 5V/1A , Power Supply 12V/1A , Bias Power Supply(Dc) , Power Supply 12V/13A , Power Supply 5V4a/15V2a , Power Supply 24V3a , Power Supply 8V3a/8V3a , Power Supply , Bearing , Clamping Set , Flanges Brass Cover , Flanges Brass Choke , Circular , Noise Source , Single Channel Rotary Joint , Dual Channel Rotary Joint , Dual Loop Coupler , Variable Attenuator C Band , Flexible Waveguides , Booster Amplifier C Band , Arc Detector C Band , Rf-Switch Spst , Waveguide Power Divider , Dummy Load , Flexible Waveguides , Dual Channel Down Converter , Stalo Unit , Tx Channel Unit , Carrier Board Type A , Pinion , Power Brush Block , Signal Brush Block , Peak Current Detector Board , Switch Array Control Board 1000 , Grease Distributor , Measuring Interface , Booster Amplifier Control Board , Current Monitor Klystron , Gun Arc Detector Board , Status Monitoring Board X4k , Status Monitoring Board X5k , Power Supply 5V/1A , Power Supply Board 18V/12V 1A , Transmitter Oil Pump , Oil Level Sensor , Bus X5 Backplane , Bus X4 Backplane , Bus X3 Backplane , Trigger Timing Board , Current Monitor Klystron , Filament Interface Board , Slip Ring , Profibus Controller , Single Board Computer , Current Monitor Shunt Klystron , Voltage Monitor Klystron , Gdrx Board Set , Profibus Module , Binary Inout Module , Rs 232 Module , Carrier Board Type C , Can Module , Ssi Controller , Gdrx Transition Module , Carrier Board , Bias Interface Board , 2Nd Lo Unit , Sensor Board , Safety Plc , Step Attenuator , Digital Servo Drive , Driver Board , Ecl/Sin Convertor Unit , Heater , Bearing , Encoder Drive Incl Coupling , Power Supply 520W , Rf-Switch Spdt , Bearing , Servo Motors (Comprising Qty 2) , Dehydrator , Klystron Cabinet (Klystron Vkc8387, Magnet Vyw 8387, Oil Isolation Tank , Main Power Supply , Centrifugal Blower Systems For Radar , Wave Guide Switch , Receiver / Signal Processor , Itsg- Integrated Test Signal Generator For Sp Calibration , Seal Kit , Grease Pump , Switch Board 1000 Rev B , Power Supply 5V/30A , Tab Tamsulosin 0.4Mg + Dutasteride 0.5 Mg , Tabnicoumalone2 Mg , Tabdicyclomine 20Mg + Paracetamol 325 Mg , Tab Sodium Valporate Cr 200Mg , Vitamin E 400Mg, Cap , Tab Nebivolol Hydrochloride 2.5Mg , Olopatadine Eye Drops , Tab Alfuzocin , Quitipine Sr 100Mg, Tab , Tab Antacid , Duloxetine 40 Mg, Tab , Azithromycin 1000Mg, Ornidazole 750Mg, Fluconazole 150Mg, Kit , Deionised Water 05 Ltr , Etophylline 231 Mg And Theophylline 69 Mg, Tab , Tabclidinium Bromide Chlodiazepoxide& Dicyclomine , Lamotrigine100 Mg , Tab Enalapril 5 Mg , Soft Neck Collar Size- M, L, Xl, Xxl , Prednisolone10 Mg Tab , Micropippette Tips 1-20 ?Lr , Pregnancy Test Strip , Dicyclominedrops , Sulphasalazine 1000Mg, Tab , Prazocin Xl 5Mg, Tab , Tab Chlomipramine 25 Mg , Terbinafine 1% Cream, Tube Of 10 Gms , Beclomethasone Valerate 0.05% W/W+ Phenylepherine Hydrochloride 0.1% W/W + Lignocain Hyddrochloride I.P 2.5% W/W In An Ointment Base , Printer Paper Roll1pkt Of 3 Roll 57Mm X 30 M , Syp B-Comlex , Vit C And Zinc , Tab Fluoxetine 20 Mg , Silver Sulphadiazine 0.20%, Chlorhexidine Gluconate 0.20%, Chlorocresol 0.12% W/W Cream Tube Of 15Gm , Tab Olmesartan 20 , Tongue Depressor Wooden , Tab Pioglitazone 30 Mg , Su Mag Jar Of 75 Gm (Magnesium Sulfate) , Feeding Bag , Ankle Support Size S, M, L, Xl , Tab Nitrofuradentin 100 Mg , Diclofenacdiethylamine,Linseed Oil,Methyl Salicylate &Menthol Spray , Tretinion Cream 0.05% , Syp Mefenamicacid +Pcm , Tab Hydrochlorthiazide12.5 Mg , Bacitracin Zinc, Neomycin Sulphate, Polymyxin B Sulphate , Powder , Omega 3 Fatty Acid, Cap , Betadine For Oral Use , Luliconazole Cream 1% W/W Tube Of 10G , Tab Mercaptopurine 50 Mg , Tab Olanzapine 5 Mg , Chlorhexidine Gluconate, Cetrimide, Gum Paint , Syp Deriphyllin Bott Of 100 Ml , Timolol 0.5% Eye Drops , Tabmetoprolol25mg , Ipratropium Bromide Solution Vial Of 10 Ml , Polyethylene Glycol 0.4% + Propylene Glycole 0.3%(Systen Ultra) Eye Drops , Melatonin 0.25 Mg Tablets , Evening Of Primrose Oil 500 Mg , Cap B Complex + Vit C + Zinc , Tab Sumitriptan50mg , Tab Rabeprazole20 , Tab Zinc , Tab Glicazide 80 Mg , Lidocaine/Lignocain(2% W/W) +Chlorhexidine Gluconate(1% W/W)+ Metronidazole 1%Oint , Inj Methotraxate15mg , Wrist Band For Support , Arm Pouch , Plastic Urine Container , Vit D Drop 400Iu/1 Ml , Oint Diltiazem , Tab Clonezpam 0.25 Mg , Beclomethasone 0.025% , Clotrimazole 1% , Lotion Bott Of 25Ml , Disposable Needle 26 1/2G , Tab Glimiperide 4Mg , Amlodepine 10Mg, Tab , Mosapride 5Mg, Tab , Aceclofenac 100Mg + Paracetamol 325Mg, Tab , Clomifene 50 Mg, Tab , Etoricoxib 60 Mg + Paracetamol 325 Mg , Cough Lozenges , Prochlorperazine Maleate 5 Mg , Tab Doxylamine+ Vit B6 (Pyridoxin) 40 , Acyclovir Skin Cream 5% Tube Of 5 Gm , Povidone Iodin Oint , Tab Haloperidol 0.25 Mg , Calamine + Diphenhydramine Hydrochloride Lotion , Tab Piracetam 400 Mg , Tab Biotin , Prednisolone Eye Drops 1 % , Tab Aceclofenac 100 Mg , Syp Haloperidol , Fluconazole Oint , Tab Isotretinion 20Mg , Tab Eltroxine 88Mcg , Nepafenac Eye Drop , Tab Amlodipine 2.5 Mg , Hypromellose (Lacrigel) Oint , Nitroglycerine,/ Glyceryl Trinitrate 2.6Mg, Tab , Milk Of Magnesia 11.25 Mg, Liq Paraffin 3.75 Mg Suspension Bott Of 100Ml , Inj Vit B1, B6 ,B12 And Calcium Pantothenate Amp Of 2 Ml (Neurobion) , Inj Vincristcin , Inj Depometrol , Hydroxyzine 10Mg, Tab , Tab Lacosamide 100 Mg , Sulphacetamide 20%Eye Drop , Inj Methylcobalamine , Syp Disodium Hydrogen Citrate (Alkacitran) Jar Of 5 Ltr , Dressing Medicated Waterproof , Suction Catheter , Moxifloxacin+Dexamethasone Eye Drop , Pp Crystals , Tess(Triamcinolone Acetonide + Choline Salicylate) Gel(Ulsore,Mouth Ulcer) , Isosorbide Mononitrate 10Mg, Tab , Corn Caps (Pkt Of 4) , Inj Lignocain 2% , Chloromphenicoleye Apps , Dexamethasone 0.1% Eye Drops , Inj Haloperidol 5 Mg/Ml
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
Himachal Pradesh View Result →
32.
Educational and Research Institute #9137129 Price Bid
Supply Of Training Materials, Raw Materials, Consumables Etc. For Different Trades- 1 Battery, 9 V, Alkaline, Flat Type for Digital Multimeter 2 P.V.C. Insulation Tape 3 Copper Wire, Multistrand, 1.5 sq. mm 4 Copper Wire, Multistrand, 2.5 sq. mm 5 Capacitor, 2.5 μFD, 250 V AC 6 Multiple Colour L.E.D. Chain (50 nos. L.E.D. in each chain) 7 G.I. Wire, 22 S.W.G. 8 Tube Light Choke, 40 W 9 Tube Light Set, Fluorescent 10 Varnish 11 Batten Holder, 5 A, 230 V 12 Shaddle for Conduit Pipe Wiring, P.V.C., Size 20 mm 13 Elbow for Conduit Pipe Wiring, P.V.C., Size 20 mm 14 Tee for Conduit Pipe Wiring, P.V.C., Size 20 mm 15 3-Pin Top, 5 A 16 Heat Sinkable Sleeve Size 2 mm 17 Heat Sinkable Sleeve Size 4 mm 18 Glass Tube Sleeve Size 1 mm 19 Glass Tube Sleeve Size 2 mm 20 Glass Tube Sleeve Size 3 mm 21 Glass Tube Sleeve Size 4 mm 22 Tungsten Filament Lamp, 60 W, 250 V 23 Tungsten Filament Lamp, 200 W, 250 V 24 Carbon Filament Lamp, 100 W, 250 V 25 Diesel fuel oil for DG set 26 Distilled water for battery 27 Resistor, 3.9 kΩ, ¼ W 28 Resistor, 560 Ω, ¼ W 29 Resistor, 1 kΩ, ¼ W 30 Resistor, 10 kΩ, ¼ W 31 Resistor, 120 Ω, ¼ W 32 Resistor, 15 kΩ, ¼ W 33 Resistor, 180 Ω, ¼ W 34 Resistor, 3.3 kΩ, ¼ W 35 Resistor, 4.7 kΩ, ¼ W 36 Resistor, 5.6 kΩ, ¼ W 37 Resistor, 560 Ω, ¼ W 38 Resistor, 680 Ω, ¼ W 39 Resistor, 8.2 kΩ, ¼ W 40 Diode - 1N4007 41 Zener Diode - 6V 1W 42 Zener Diode - 9V 1W 43 Zener Diode - 12V 1W 44 Transistor -CL100 45 Transistor -SK100 46 IC Vero Board - 5.5 × 2 Continuous Horizontal tracks (19 Rows) 47 IC Vero Board - 5.5 × 3.5 Continuous Horizontal tracks 48 Single Strand Hook-up Wire, 1/25, Black 49 Single Strand Hook-up Wire, 1/25, Blue 50 Single Strand Hook-up Wire, 1/25, Green 51 Single Strand Hook-up Wire, 1/25, Red 52 Single Strand Hook-up Wire, 1/25, Yellow 53 Flexible Multistrand Wire - 1 sq. mm, Black 54 Flexible Multistrand Wire - 1 sq. mm, Green 55 Flexible Multistrand Wire - 1 sq. mm, Red 56 Arduino Uno Board with USB connecting Cable 57 IC - MK484 58 NTC 10 kΩ Thermistor Temperature Sensor Cylinder Probe 1.5 m Wire 59 RTD Sensor - PT 100 60 Temperature Sensor - DHT11 61 Temperature Sensor IC-LM35 62 LDR Big Size 63 IC - CD4017 64 IC - LM7805 65 Transistor - TIP122 66 Diode - 1N4148 67 Diode - 1N5402 68 LED Driver Board for 9 W LED Bulb 69 LED Driver Board for 12 W LED Bulb 70 LED Bulb - 5 W 71 LED Bulb - 14 W 72 P.V.C. WhiteBoard, 8 × 6 (Multipurpose Electrical Board) 73 5-Pin Socket, 230 V, 6 A , White 74 3-Pin Plug, 230 V, 6 A, Male, White 75 ON-OFF Switch, 250 V, 6 A Piano Type, White 76 Kit-Kat Fuse with Holder, 250 V, 10 A, White 77 RJ45 Plug Connector 78 IC - NE555 79 IC - LM741 80 Insulation Tape - 10 mBlack 81 Insulation Tape - 10 mBlue 82 Insulation Tape - 10 mGreen 83 Insulation Tape - 10 mRed 84 Insulation Tape - 10 mYellow 85 Transistor - 2N2222 (Metal Body) 86 Acid Cell Rechargeable Battery, 12 V, 7 AH 87 Acid Cell Rechargeable Battery, 6 V, 7 AH 88 LED Tube Light, 20 W 89 SMD Capacitors (Any Values) 90 SMD Resistors (Any Values) 91 SMD Transistor (Any Values) 92 Capacitor - 100 µF, 63 V 93 Capacitor - 220 µF, 63 V 94 Capacitor - 1000 µF, 50 V 95 Capacitor - 4.7 µF, 63 V 96 Capacitor - 22 µF, 63 V 97 Capacitor - 470 µF, 50 V 98 Stepper Motor - NEMA17 (Four Wired) 99 Power Transistor- 2N3055 100 Solder (60:40), 50 g/ each 101 Solder Wick, Copper, 5 meter/ each 102 Soldering Flux Paste - 10 CC Syringe Convenient Tube 103 Liquid Solder Flux - IPA Solution, 500 ml/ bottle 104 LED - 5mmRed 105 Condenser MIC 106 Cat 6 Cable 107 UJT-2646 108 IC - 7400 109 IC - 7404 110 IC - 7408 111 IC - 7432 112 IC - 7486 113 Opto Coupler - 4N35 114 Four Channel Relay Module - 5 V Relay Module with Opto Coupler 115 Wire Wound Resistor, 100 Ω, 5 W 116 Wire Wound Resistor, 100 Ω, 10 W 117 Wire Wound Resistor, 1 kΩ, 5 W 118 Ceramic Resistor - 100 Ω, 10 W 119 Ceramic Resistor - 47 Ω, 5 W 120 Network Resistance or Resistance Array - 1 kΩ 121 Network Resistance or Resistance Array - 4.7 kΩ 122 Wire Wound POT - 100 Ω, 3 W 123 Wire Wound POT - 1 kΩ, 3 W 124 Preset - Multi-Turn 19mm Preset, 1KΩ 125 Preset - 3-Pin Single Turn Trimpot, 1 kΩ 126 Preset - 3-Pin Single Turn Trimpot, 4 kΩ 127 Preset - 3-Pin Single Turn Trimpot, 10 kΩ 128 Preset - 3-Pin Single Turn Trimpot, 100 kΩ 129 Preset - 3-Pin Single Turn Trimpot, 1 MΩ 130 Precision Multiturn Potentiometer (POT), 10 kΩ 131 Dual Channel POT, 10 kΩ 132 Volume Control, 10 kΩ 133 Loud Speaker - Ø2.5 inch, 5 W, 4 Ω 134 IC - LM 386 135 IC - TDA2030 136 Polyester Type Capacitor, 0.1 µF, 400 V 137 Tantalum Capacitor,4.7 µF, 25 V 138 Tantalum Capacitor,100 µF, 16 V 139 Capacitor, 0.01 µF, 275 V x 2 Box Type Safety Capacitor 140 Capacitor, 22 µF, 35 V Case D Chip Tantalum Capacitor (SMD) 141 Capacitor, 100 µF, 35 V Case D Chip Tantalum Capacitor (SMD) 142 Capacitor, 100 µF, 25 V SMD Aluminum Electrolytic Capacitor 143 Capacitor, 470 µF, 350 V SMD Aluminum Electrolytic Capacitor 144 Capacitor, 220 µF, 50 V SMD Aluminum Electrolytic Capacitor 145 SMD Resistor, 1% 0.125 W 0805 Package:10 Ω 146 SMD Resistor, 1% 0.125 W 0805 Package:1 kΩ 147 SMD Resistor, 1% 0.125 W 0805 Package:10 kΩ 148 SMD Resistor, 1% 100 mW 0603 Package:100 Ω 149 SMD Resistor, 1% 100 mW 0603 Package:1 kΩ 150 SMD Resistor, 1% 100 mW 0603 Package:10 kΩ 151 SMD Resistor, 1% 100 mW 0603 Package:330 kΩ 152 SMD Resistor, 1% 100 mW 0603 Package:1MΩ 153 SMD Resistor, 1% 0.125 W 1206 Package:1 kΩ 154 SMD Resistor, 1% 0.125 W 1206 Package:10 kΩ 155 SMD Resistor, 1% 0.063 W 0402, Package:2 kΩ 156 SMD Resistor, 1% 0.063 W 0402, Package:22 Ω 157 SMD Capacitor, 0603 Package: 47 pF, 50 V 158 SMD Capacitor, 0603 Package: 100 nF, 50 V 159 SMD Capacitor, 0603 Package: 10 µF (10000 nF), 50 V 160 SMD Capacitor, 0805 Package: 1 µF (1000 nF) 50 V 161 SMD Capacitor, 0805 Package: 4.7 µF,25 V 162 SMD Capacitor, 0805 Package: 10 µF/ 10000 nF, 50 V 163 SMD Capacitor, 1206 Package: 22 nF, 50 V 164 SMD Capacitor, 1206 Package: 10 µF, 25 V 165 Varistor - Ø14 mm, 270 V 166 IR LED, 5 mm, White 167 Photo Diode, 5 mm, Black 168 ELCB, 40 A, Single-Phase, 2-Pole ELCB + RCCB + With High Voltage, Leakage Current 3 to 30 mA (White) 169 Power Contactor - 3-Phase, 4-Pole, 12 A 170 Power Contactor - Single-Phase LT 3-Pole Power Contactor, 16 A 171 M.C.B. - 2-Pole, 10 A 172 Metallized Polyester Film Capacitor, Axial Type - 2.2 μF, 250 V 173 Metallized Polyester Film Capacitor 6000 nF, 50 V, 605J 174 Electrolytic Capacitor, 4.7 µF, 400 V 175 Electrolytic Capacitor, 100 µF, 400 V 176 IC - 74153 177 IC - 74155 178 Crystal - 1 MHz 179 Crystal - 4 MHz 180 Crystal - 455 kHz 181 M.S. Flat, 50 mm x 8 mm x 50 m 182 M.S. Flat, 50 mm x 10 mm x 20 m 183 M.S. Flat, 65 mm x 8 mm x 80 m 184 M.S. Flat, 75 mm x 10 mm x 30 m 185 Hacksaw Blade, 300 mm x 12.5 mm x 18 TPI HSS 186 Engine Oil, SAE 15W 30 187 File Handle, Wooden, 4 188 File Handle, Wooden, 6 189 Cotton Waste 190 Resistor, 1 kΩ, ¼ W 191 Resistor, 1 MΩ, ¼ W 192 Resistor, 1.2 kΩ, ¼ W 193 Resistor, 1.5 kΩ, ¼ W 194 Resistor, 10 kΩ, ¼ W 195 Resistor, 10 MΩ, ¼ W 196 Resistor, 100 kΩ, ¼ W 197 Resistor, 100 Ω, ¼ W 198 Resistor, 12 kΩ, ¼ W 199 Resistor, 120 kΩ, ¼ W 200 Resistor, 15 kΩ, ¼ W 201 Resistor, 150 kΩ, ¼ W 202 Resistor, 150 Ω, ¼ W 203 Resistor, 220 kΩ, ¼ W 204 Resistor, 220 Ω, ¼ W 205 Resistor, 3.3 kΩ, ¼ W 206 Resistor, 3.9 kΩ, ¼ W 207 Resistor, 33 kΩ, ¼ W 208 Resistor, 330 Ω, ¼ W 209 Resistor, 4.7 kΩ, ¼ W 210 Resistor, 47 kΩ, ¼ W 211 Resistor, 47 Ω, ¼ W 212 Resistor, 470 Ω, ¼ W 213 Resistor, 56 kΩ, ¼ W 214 Resistor, 56 Ω, ¼ W 215 Resistor, 6.8 kΩ, ¼ W 216 Resistor, 6.8 kΩ, ¼ W 217 Resistor, 8.2 kΩ, ¼ W 218 Resistor, 1 kΩ, ½ W 219 Resistor, 100 Ω, ½ W 220 Resistor, 47 Ω, ½ W 221 POT (Carbon Type), 1 kΩ, ¼ W 222 POT (Carbon Type), 10 kΩ, ¼ W 223 POT (Carbon Type), 100 kΩ, ¼ W 224 POT (Carbon Type), 1MΩ, ¼ W 225 POT (Carbon Type), 22 kΩ, ¼ W 226 POT (Carbon Type), 47 kΩ, ¼ W 227 Breadboard, 830 Pins High Quality, White 228 P.V.C. Wire, 1 Sq. mm, Black 229 P.V.C. Wire, 1 Sq. mm, Green 230 P.V.C. Wire, 1 Sq. mm, Red 231 Flexible Multistrand P.V.C. Wire, 1/36, Green 232 Flexible Multistrand P.V.C. Wire, 1/36, Black 233 Flexible Multistrand P.V.C. Wire, 1/36, Blue 234 Flexible Multistrand P.V.C. Wire, 1/36, Red 235 Flexible Multistrand P.V.C. Wire, 1/36, Yellow 236 Hook-up Wires, 1/25, Black 237 Hook-up Wires, 1/25, Blue 238 Hook-up Wires, 1/25, Green 239 Hook-up Wires, 1/25, Red 240 Hook-up Wires, 1/25, Yellow 241 3-Pin plug, 250 V, 6 A 242 IC Vero Board - 5.5 X 3.5, Continuous Horizontal Tracks 243 IC Vero Board - 5.5 X 2, Continuous Horizontal Tracks (19 Rows) 244 Solder (60:40), 50 g/each 245 Solder Wick (Copper), 5 m/each 246 Soldering Flux Paste, 10 CC Syringe Convenient Tube 247 Liquid Solder Flux, IPA Solution, 500 ml/bottle 248 LED - 5 mm, Blue 249 LED - 5 mm, Green 250 LED - 5 mm, Orange 251 LED - 5 mm, Red 252 LED - 5 mm, White 253 LED - 5 mm, Yellow 254 Seven Segment Display - Common Anode Type 255 Seven Segment Display - Common Cathode type 256 Insulation Tape, 10 m, Black 257 Insulation Tape, 10 m, Red 258 Insulation Tape, 10 m, Green 259 Insulation Tape, 10 m, Yellow 260 Incandescent Lamp, 230 V, 60W 261 Incandescent Lamp, 230 V, 100W 262 Diode, 1N4007 263 Zener Diode, 6 V, 1 W 264 Zener Diode, 9 V, 1 W 265 Zener Diode, 12 V, 1 W 266 SPDT Switch (Toggle Type), 1A 267 LDR Big Size 268 Condenser MIC 269 Battery, Alkaline, AA 270 Battery, Alkaline, AAA 271 Lead Acid Cell Battery, 12 V, 7 AH 272 Solenoid Valve, 12V DC, ½ inch 273 Arduino UNO R3 Compatible Board + Cable for Arduino Uno 274 8266 Node MCU Board + Cable for Node MCU 275 Proximity Sensor, PNP Type 276 Temperature Sensor, IC-LM35 277 Capacitor, 10 µF, 63 V 278 Capacitor, 100 µF, 63 V 279 Capacitor, 1000 µF, 50 V 280 Capacitor, 22 µF, 63 V 281 Capacitor, 220 µF, 50 V 282 Capacitor, 3.3 µF, 6 3V 283 Capacitor, 470 µF, 50 V 284 Capacitor, 0.1 µF 285 Capacitor, 0.01 µF 286 Capacitor, 0.001 µF 287 Transistor, CL100 288 PIR Sensor Module 289 Temperature & Humidity Module (DHT11) 290 IR Proximity Sensor Module 291 SIM 900A GSM Module 292 GPS Receiver Module with RS232 and Antenna 293 LCD Display, 16 x 2 294 Motor, DC, 9V 295 IC Base, 8 pin 296 IC Base, 14 Pin 297 IC Base, 16 Pin 298 IC Base, 20 Pin 299 UJT-2646 300 FET-BFW10 301 TRIAC-136 302 SCR-TYN616 303 DIAC-DB7 304 M.C.B.- Single-Pole, 240V, 10A 305 ELCB, 40 A, Single-Phase, 2-Pole ELCB + RCCB + With High Voltage, Leakage Current 3 to 30 mA (White) 306 Wire Wound Resistor, 100 Ω, 5 W 307 Wire Wound Resistor, 1K Ω, 10 W 308 Tantalum Capacitor, 10 µF, 63 V 309 Tantalum Capacitor, 100 µF, 63 V 310 Polyester/Metal Flim Capacitor, 0.1 µF, 400 V 311 Polyester/Metal Flim Capacitor, 0.047 uF, 400 V 312 Power Adapter, DC, 12 V, 2 A 313 IR Proximity Sensor Module 314 2A Dual L298N Motor Driver Module with PWM Control 315 P.V.C. White Colour Multipurpose box, 8 X 6 316 5-pin White Coloured Socket, 250 V, 10 A 317 ON-OFF Switch, 250 V, 6 A, Piano Type, White 318 Kit-Kat Type Fuse, 250 V, 10 A, White 319 Battery, 9 V, Alkaline, Flat Type for Digital Multimeter 320 Transformer, 230 V, 15-0-15, 1 A 321 IC - NE555 322 IC - LM71 323 IC - LM7805 324 IC - LM7812 325 IC - LM321 326 IC- 7447 327 IC - 7448 328 IC - 7490 329 IC - 7473 330 IC - 74153 331 Ultrasonic Sensor Module, HC-SR-04 332 IC -7400 333 IC - 7404 334 IC - 7408 335 IC - 7432 336 IC - 7486 337 Capacitor, 0.01 μF, 275 V, X2 Box Type Safety Capacitor 338 NTC 10 kΩ Thermistor Temperature Sensor Cylinder Probe with1.5 m Wire 339 Servo Motor - SG 90 Micro Servo Motor 340 IR LED, 5 mm, White 341 Photo Diode, 5 mm, Black 342 Opto Coupler - 4N35 343 Transistor - BC558 344 Transistor - BC557 345 Power Transistor- 2N3055 346 Miniature Relay - 1CO, 12 V 347 Four Channel Relay module - 5V Relay Module with Opto Coupler 348 LED Lamp, 240 V, 15 W 349 C.I. Block, 60 mm x 60 mm x 60 mm 350 C.I. Block, 80 mm x 60 mm x 30 mm 351 M.S. Flat, 50 mm x 10 mm x 10 m 352 M.S. Square Bar, ½” x ½” x 10 m 353 M.S. Round Bar, Ø50 mm X 10 m 354 Hacksaw Blade, 300 mm x 12.5 mm x 24 TPI HSS 355 HSS Tool Bit, 3/8” x 3/8” x 3” 356 Wheel Star Dresser with handle No.1 357 Power Saw Blade, HSS, 300 x 25 x 1.25 358 Lubricating Oil, IS 1513-2015 359 C.I. Block, 40 mm x 20 mm x 120 mm 360 C.I. Round, Ø 150 mm x 25 mm 361 M.S. Round Bar, Ø 30 mm x 10 m 362 C.I. Block, 60 mm x 60 mm x 60 mm 363 Diamond Dresser For Wheel Dressing – 0.50 carat 364 Grinding Wheel - 150 mm x 13 mm x 31.75 mm, 38A60K5Vbe 365 Grinding Wheel - 150 mm x 19.5mm x 31.75 mm Type-P, Silicon Carbide, Coarse 366 Grinding Wheel - 150 mm x 19.5mm x 31.75 mm Type-P, Silicon Carbide, Fine 367 Grinding Wheel - 150 mm x 19.5mm x 31.75 mm Type-P, Aluminum Oxide, Coarse 368 Grinding Wheel - 150 mm x 19.5 mm x 31.75 mm Type-P, Aluminum Oxide, Fine 369 Grinding Wheel – 200 mm x 25 mm x 31.7 mm Type-E, 34G301, Coarse 370 Grinding Wheel - 200 mm x 25 mm x 31.7 mm Type-E, 34G301, Fine 371 Grinding Wheel - 10” mm x 1½” x 4” Type-A, Coarse 372 Grinding Wheel - 10” x ½” x 4” Type-A, Fine 373 Soluble Oil, IS: 1115-1986 (Reaffirmed 1996) 374 Dressing Stone, 150 mm x 25 mm x 25 mm, Medium Grit - 24, Silicon Carbide 375 M.S Round (Ø40 x 5 Mtr) 376 M.S Round (Ø50 x 5 Mtr) 377 Servo Cut (S) 378 Cleaning Oil 379 Emery paper (120) 380 H.S.S Tool bit (3/8” x 3/8”x 4 mm) 381 M.S Flat (20x8 )mm 382 Engine Oil 383 Power saw (14”) 384 Hacksaw blade,24TPI HSS, 300 mm x 12.5 mm 385 Grinding wheel (150x13x31.75mm)(38A60KSVBE) 386 Oil stone Carborandum (200x50x25)mm 387 Fully automatic battery charger,Primary: Rated input voltage: 230V~240V/50JHz , starting current:< 50A, rated input current: max. 1.2A (rms value), Power input :135 W, Secondary: rated output voltage 12V& 24V 388 Hydraulic Pressure test machine (5Kg) 389 1 HP Booster Pump 390 1 HP Compressor Pump 391 Bib Cock (Brass) 392 Piller Cock (Brass) 393 Angular stop cock 394 1” ball valve (P.V.C) 395 1” Gate valve (Brass) 396 1.5 inch Concealed flash valve 397 15 Ltr Concealed Cistern 398 14” pipe wrench 399 10” screw driver 400 2mm to 15 mm Allen key screw driver 401 15 mm tapset with handle 402 Wheel pipe cutter 403 P.V.C pipe cutter 404 10” adjustable wrench 405 1” P.V.C Pipe 406 3/4” P.V.C Pipe 407 3/4” C.P.V.C Pipe 408 1” Elbow P.V.C 409 1” Tee P.V.C 410 1” socket 411 2” Tee P.V.C 412 2” elbow P.V.C 413 2” socket P.V.C 414 Flare Nut, ؼ, Brass, ISI 415 Refrigerant, R134a, 450 g Container 416 Refrigerant, HC Blend 170 g Container 417 Refrigerant, R22 418 Pin Valve, Non Return, ¼ O.D. 419 Brazing Stick (for copper pipe brazing) 420 Brazing Gas (Butane), 220 g Container 421 Capillary Tube, 0.031 (0.7 mm) I.D. 422 Dead Nut, Brass, ¼ I.D. 423 Terminal Clip (for comp. motor) 424 3-Way Hand Shut-off Valve, ¼ O.D. (for gas charging/ vacuum) 425 Capillary Tube, 1.25 mm I.D. 426 Gas Charging Flexible Pipe, 3 ft Long, ؼ, 450 PSIG 427 Dry Nitrogen Gas (without cylinder) 428 Run Capacitor, 440 V, 50 µF 429 Run Capacitor, 440 V, 6 µF 430 Run Capacitor, 440 V, 4 µF 431 Brazing Blow Torch (for butane gas cans) 432 Tube Cutter (Copper), with spare blade 433 Copper Wire, 0.5 sq. mm 434 Batten Holder, 230 V, 5 A 435 Pendant Holder, 230 V, 5 A 436 One-Way Switch, 230 V, 6 A, Piano Type 437 Two-Way Switch, 230 V, 6 A, Piano Type 438 P.V.C. Board, 2 x 2 439 P.V.C. Board, 4 x 4 440 P.V.C. Capping & Casing, ¾, 10 ft 441 P.V.C. Conduit/Pipe, ½, 10 ft 442 Saddle, 20 mm 443 Elbow, 20 mm 444 Tee, 20 mm 445 Casing Saddle 446 Socket, 3-Pin, 230 V, 6 A 447 M.C.B., 2-Way, 2-Pole, 16 A 448 M.C.B., 2-Way, 2-Pole, 32 A 449 Gypsum Screw, ½ 450 2-Pin Plug, 230 V, 6 A 451 3-Pin Plug, 230 V, 6 A 452 Battery for LEICA Total Station, Model-GEB121 453 Battery for LEICA Total Station, Model-GEB212 454 Battery forFOIF Digital Theodolite 455 M.S. Round, Ø50 mm 456 M.S. Round, Ø40 mm 457 M.S. Round, Ø65 mm 458 Cast Iron Round bar, Ø120 mm x 300 mm 459 M.S. Flat, 10 mm x 75 mm 460 Tool Bit, HSS, 3/8 x 3, S-500 461 Centre Drill, Bit A4 462 Machine Oil, IS: 1115-1986 (Reaffirmed 1996) 463 Star Wheel Dresser Cutter No.1 464 Diamond Wheel Dresser, 0.5 carat 465 Soap Bar 125 gm 466 V Belt, A26 467 Cloth Duster 468 M8 Nut 469 M6 x 25 mm Bolt (Socket Headed) 470 M4 x 25 mm Bolt (Socket Headed) 471 M10 x 40 mm Bolt 472 Bolt, ¼ x 1 473 Nut, ¼ x 1 474 Hexagonal Long bolt, 3/8 x 1.5 475 Nut, 3/8 x 1.5 476 Hexagonal Bolt, 5/16 x 1.5 477 Nut, 5/16 x 1.5 478 Water Paper Mesh, Size 400 479 M. S. Flat, 6 mm x 50 mm x 250 m 480 M. S. Flat, 8 mm x 50 mm x 150 m 481 M. S. Flat, 10 mm x 50 mm x 100 m 482 M.S. Pipe, Ø50 x WT 3 mm x 400 483 M.S. Electrode, Ø3.15 mm 484 C.C.M.S. Filler Rod, Ø1.6 mm 485 M.S. Sheet, 2 mm x4 x 8 x 2 no 486 M.S. Sheet, 3 mm x 4 x 8 x 2 no 487 Aluminium Sheet, Grade 100, 3 mm x 4 x 8 x 1 no 488 MIG Welding Wire Spool, Ø0.8 mm 489 MIG Welding Wire Spool, Ø1.2 mm 490 Silicon Spray for MIG Welding 491 MIG Welding Contact Tip, 0.8 mm, rate to be quoted after paying physical visit at ITI Tollygunge. 492 MIG Welding Contact Tip, 0.8 mm, rate to be quoted after paying physical visit at ITI Tollygunge. 493 MIG Welding Contact Tip, 0.8 mm, rate to be quoted after paying physical visit at ITI Tollygunge. 494 MIG Welding Contact Tip, 0.8 mm, rate to be quoted after paying physical visit at ITI Tollygunge. 495 MIG Welding Contact Tip, 0.8 mm, rate to be quoted after paying physical visit at ITI Tollygunge. 496 Emery Cloth - 100 Grit 497 Emery Cloth - 120 Grit 498 Hacksaw Blade, 300 mm x 12.5 mm x 24 TPI, HSS 499 LED Bulb for Welding Booth, 20 W 500 Alotectic Flux 501 Brazotectic Flux 502 Chipping Goggles, White 503 Cotton Gloves for TIG Welding as per sample 504 SAW Wire Spool as per sample 505 Flow Meter, Argon, ISI 506 Flow Meter, CO2, ISI 507 CO2 Spindle Key 508 MIG Welding Nozzle as per sample 509 AG4 Grinding Wheel, Wheel Ø100 mm x 6 mm x Bore Ø16 mm 510 AG4 Grinding Cutter, Wheel Ø105 mm x 1.2 mm x Bore Ø16 mm 511 Arc Welding Cable. 600 A, Ø95 sq. mm 512 M.S. Sheet, 1 mm x 4 x 8 x 3 nos 513 Apron for Welding 514 Plasma Cutting Tip with Nozzle as per sample 515 Abrasive Cutter Wheel, Ø355 mm x 3.0 mm x 25.4 mm 516 Male Connector for Welding Cable as per sample 517 Teflon Tape, ½ 518 Cable Lugs Aluminium as per sample 519 Electrode Holder ESAB makes, 400 A 520 Lubricant for Machine & Movable Parts, SAE 15W30 521 Pedestal Grinder Wheel, Wheel Ø300 mm x 40 mm x Bore Ø50 mm, Coarse 522 Pedestal Grinder Wheel, Wheel Ø300 mm x 40 mm x Bore Ø50 mm, Medium 523 Pedestal Grinder Wheel,Wheel Ø250 mm x 25 mm x Bore Ø30 mm, Coarse 524 Pedestal Grinder Wheel,Wheel Ø250 mm x 25 mm x Bore Ø30 mm, Medium 525 Pedestal Grinder Wheel,Wheel Ø300 mm x 40 mm x Bore Ø100 mm, Coarse 526 Pedestal Grinder Wheel,Wheel Ø300 mm x 40 mm x Bore Ø100 mm, Medium 527 Gas Welding Nozzle Size No. 1 528 Gas Welding Nozzle Size No. 2 529 Gas Welding Nozzle Size No. 3 530 P.V.C. Conduit Pipe - ¾ 531 P.V.C. Elbow - ¾ 532 P.V.C. T - ¾ 533 P.V.C. Saddle - ¾ 534 P.V.C. Box, 3 x 3 with Cover 535 P.V.C. Box, 4 x 4 with Cover 536 P.V.C. Box, 8 x 6 with Cover 537 Ceiling Rose 5 A, 230 V, Piano Type 538 P.V.C. Holder (BL Batten) 5 A, 230 V 539 Copper Wire, 1 sq. mm 540 Copper Wire, 1.5 sq. mm 541 Copper Wire, 2.5 sq. mm 542 Power Contactor, 2 NO + 2 NC, 400 V 543 Over load Relay, 6-14 A, 400 V 544 ON Push Switch (Heavy Duty), 6 A, 400 V, Green Colour 545 OFF Push Switch (Heavy Duty), 6 A, 400 V, Red Colour 546 Digital Timer for Star Delta Starter 547 Control Panel Indicator, Red, 230 V, 5 mm 548 Control Panel Indicator, Yellow, 230 V, 5 mm 549 Control Panel Indicator, Blue, 230 V, 5 mm 550 Intermediate Switch, Piano Type, 5 A, 220 V 551 One-way Switch, Piano Type, 5 A, 220 V 552 Two-way Switch, Piano Type, 5 A, 220 V 553 3-Pin Plug Top, 6 A, 230 V 554 3-Pin Plug Top, 16 A, 230 V 555 Pendent Holder, 6 A, 230 V 556 Socket, 6 A, 230 V 557 Socket, 16 A, 230 V 558 P.V.C. Tape, 3 m, Red 559 P.V.C. Tape, 3 m, Yellow 560 P.V.C. Tape, 3 m, Blue 561 P.V.C. Tape, 3 m, Black 562 Bridge Rectifier Metal Case, 1Ø , 35 A, 230 V 563 Hook-up Wire, 1/25 CU 564 Diode, 4007 IC 565 7806 IC 566 Soldering Wire 567 Super Enamelled CU Wire, 36 SWG 568 Insulation Varnish 569 Battery 12V, 100AH, SMF(Sealed Maintenance Free) 570 Mahogany Wood - 2 x 1 x 6- 0 571 Mahogany Wood - 2 x 1 ½ x 6- 0 572 Mahogany Wood - 2 x 2 x 6- 0 573 Mahogany Wood - 3 x 1 x 6- 0 574 Mahogany Wood - 3 x 1 ½ x 6- 0 575 Mahogany Wood - 4 x 1 x 6- 0 576 Mahogany Wood - 6 x 1 x 6- 0 577 Sal Wood - 2 x 2 x 6- 0 578 Sal Wood - 3 x 1 x 6- 0 579 Pine Wood - 2 x 2 x 6- 0 580 Pine Wood - 3 x 1 x 6- 0 581 Pine Wood - 6 x 1 x 6- 0 582 Gamari Wood - 2 x 2 x 6- 0 583 Gamari Wood - 3 x 1 x 6- 0 584 Methylated Spirit (95% by volume/ 66 OP of alcohol ) 585 Shellac (Gala) 586 Engine Oil, SAE 15W 30 587 ESC:40A 2-4S ESC for BLDC motor used in drone 588 Plastic Landing Gear fro S500Quadcopter Frame ( 4 nos for each set) 589 Propeller Guard for S500 Quadcoupter frame( 4 nos for each set) 590 BLDC Motor ffor quadcopter drone: RS2212 - 920KV 591 Nut Cap for 2212 920KV Brushless DC Motor used in drone ( 2 nos for Clockwise & 2 nos for Anti clockwise) 592 Propeller for Quadcopter drone- 11x4.7 (1147)Carbon Fiber (2 nos for CW and 2 nos for CCW) 593 GPS Module with Compass for APM/Pixhawk (for quadcopter drone) 594 Battery- 3300mAH, LiPo3 cell 11.1V 595 433Mhz 100mw Telemetry Module ( 01 no for laptop and 01 no for Flight controller) 596 Audio Video Transmitter and Receiver module for drone -5.8GhZ 597 Power module for quadcopter drone- APM/Pixhawk Power Module V6.0 Output BEC 3A XT60 Plug 28V 90A 598 Pixhawk Flight Controller Autopilot Kit 599 Various Body screws set for S500 Quadcopter Frame 600 200mm x 4.8 mm White/Clear Cable Ties( 100 nos each packet) 601 200mm x 4.8 mm White/Clear Cable Ties( 100 nos each packet) 602 USB 3.1 to Gigabit Ethernet Adapter 603 S500 Quadcopter Air PCB Frame with Plastic Landing Gear
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
West Bengal View Result →
33.
Defence #9117829 Technical Bid
Procurement Of 151 Lines Of Dwr ( Met ) Procurement Of 151 Lines Of Dwr ( Met ) , Fan 80Mm , Solenoid C Band , Potentiometer , Blower Motor Capacitor , Fuse 2, 5At , Fuse Monitor , Automatic Circuit Breaker 2A , Automatc Circuit Breaker 10A , Automatic Breaker 6A , Automatic Breaker 32A , Automatic Breaker 16 A , Automatic Breaker 10A , Automatic Breaker 15A , Contactor , Contactor , Relay , Relay 24Vdc 10A , Free-Wheeling Diode , Under Voltage Relays , Plc Interface Relay , Phase Sequence Monitor , Relay 12V Dc 10A , Limit Switch , Emergency Switch , Level Switch , Key Switch , Switch , Selector Switch , Diffuse Reflection Sensor , Motor Protection Switch , Pulse Transformer C1000 , Bias Choke Coil , Vac-Ion Power Supply Board , Clamping Set , Soft Starter , Centrifugal Solenoid Blower , Centrifugal Tube Blower / Collector Blower , Axil Blower , Optical Encoder , Fan 40 Mm , Safety Valve , Fieldbus Digital Out Ttl , Fieldbus End Module , Fieldbus Digital In Ttl , Fieldbus Terminal 4Dig In 24V , Fieldbus Terminal 4Dig Out 24V , Fieldbus Terminal 4 Analog Out 0-10V , Fieldbus Terminal 4Analog In 0-10V , Isolating Amplifier , Vmebus Power Supply , Servo Drive Power Supply , Power Supply 24V4a , Power Supply 5V / 5A , Power Supply 24V / 3A , Power Supply 24V / 3A , Solenoid Power Supply , Power Supply12v / 15A , Power Supply 5V / 1A , Power Supply 12V / 1A , Bias Power Supply ( Dc ) , Power Supply 12V / 13A , Power Supply 5V4a / 15V2a , Power Supply 24V3a , Power Supply 8V3a / 8V3a , Power Supply , Bearing , Clamping Set , Flanges Brass Cover , Flanges Brass Choke , Circular , Noise Source , Single Channel Rotary Joint , Dual Channel Rotary Joint , Dual Loop Coupler , Variable Attenuator C Band , Flexible Waveguides , Booster Amplifier C Band , Arc Detector C Band , Rf-Switch Spst , Waveguide Power Divider , Dummy Load , Flexible Waveguides , Dual Channel Down Converter , Stalo Unit , Tx Channel Unit , I / O Module 12 Bit , Carrier Board Type A , Pinion , Fieldbus Coupler , Profibus Coupler , Power Brush Block , Signal Brush Block , Peak Current Detector Board , Switch Array Control Board 1000 , Grease Distributor , Measuring Interface , Booster Amplifier Control Board , Current Monitor Klystron , Gun Arc Detector Board , Status Monitoring Board X4k , Status Monitoring Board X5k , Power Supply 5V / 1A , Power Supply Board 18V / 12V 1A , Transmitter Oil Pump , Oil Level Sensor , Bus X5 Backplane , Bus X4 Backplane , Bus X3 Backplane , Trigger Timing Board , Current Monitor Klystron , Filament Interface Board , Slip Ring , Profibus Controller , Single Board Computer , Current Monitor Shunt Klystron , Voltage Monitor Klystron , Gdrx Board Set , Profibus Module , Binary Inout Module , Rs 232 Module , Carrier Board Type C , Can Module , Ssi Controller , Gdrx Transition Module , Carrier Board , Bias Interface Board , 2Nd Lo Unit , Sensor Board , Safety Plc , Step Attenuator , Digital Servo Drive , Driver Board , Ecl / Sin Convertor Unit , Heater , Bearing , Encoder Drive Incl Coupling , Power Supply 520W , Rf-Switch Spdt , Bearing , Servo Motors ( Comprising Qty 2 ) , Dehydrator , Klystron Cabinet ( Klystron Vkc8387, Magnet Vyw 8387, Oil Isolation Tank , Main Power Supply , Centrifugal Blower Systems For Radar , Wave Guide Switch , Receiver / Signal Processor , Itsg- Integrated Test Signal Generator For Sp Calibration , Seal Kit , Grease Pump , Switch Board 1000 Rev B , Power Supply 5V / 30A , Sulphasalazine 1000Mg, Tab , Prazocin Xl 5Mg, Tab , Tab Chlomipramine 25 Mg , Terbinafine 1% Cream, Tube Of 10 Gms , Beclomethasone Valerate 0.05% W / W+ Phenylepherine Hydrochloride 0.1% W / W + Lignocain Hyddrochloride I.P 2.5% W / W In An Ointment Base , Printer Paper Roll1pkt Of 3 Roll 57Mm X 30 M , Syp B-Comlex , Vit C And Zinc , Tab Fluoxetine 20 Mg , Silver Sulphadiazine 0.20%, Chlorhexidine Gluconate 0.20%, Chlorocresol 0.12% W / W Cream Tube Of 15Gm , Tab Olmesartan 20 , Tongue Depressor Wooden , Tab Pioglitazone 30 Mg , Su Mag Jar Of 75 Gm ( Magnesium Sulfate ) , Feeding Bag , Ankle Support Size S, M, L, Xl , Tab Nitrofuradentin 100 Mg , Diclofenacdiethylamine, Linseed Oil, Methyl Salicylate &Menthol Spray , Tretinion Cream 0.05% , Syp Mefenamicacid +Pcm , Tab Hydrochlorthiazide12.5 Mg , Bacitracin Zinc, Neomycin Sulphate, Polymyxin B Sulphate , Powder , Omega 3 Fatty Acid, Cap , Betadine For Oral Use , Luliconazole Cream 1% W / W Tube Of 10G , Tab Mercaptopurine 50 Mg , Tab Olanzapine 5 Mg , Chlorhexidine Gluconate, Cetrimide, Gum Paint , Syp Deriphyllin Bott Of 100 Ml , Timolol 0.5% Eye Drops , Tabmetoprolol25mg , Ipratropium Bromide Solution Vial Of 10 Ml , Polyethylene Glycol 0.4% + Propylene Glycole 0.3% ( Systen Ultra ) Eye Drops , Melatonin 0.25 Mg Tablets , Evening Of Primrose Oil 500 Mg , Cap B Complex + Vit C + Zinc , Tab Sumitriptan50mg , Tab Rabeprazole20 , Tab Zinc , Tab Glicazide 80 Mg , Lidocaine / Lignocain ( 2% W / W ) +Chlorhexidine Gluconate ( 1% W / W ) + Metronidazole 1%Oint , Inj Methotraxate15mg , Wrist Band For Support , Arm Pouch , Plastic Urine Container , Vit D Drop 400Iu / 1 Ml , Oint Diltiazem , Tab Clonezpam 0.25 Mg , Beclomethasone 0.025% , Clotrimazole 1% , Lotion Bott Of 25Ml , Disposable Needle 26 1 / 2G , Tab Glimiperide 4Mg , Amlodepine 10Mg, Tab , Mosapride 5Mg, Tab , Aceclofenac 100Mg + Paracetamol 325Mg, Tab , Clomifene 50 Mg, Tab , Etoricoxib 60 Mg + Paracetamol 325 Mg , Cough Lozenges , Prochlorperazine Maleate 5 Mg , Tab Doxylamine+ Vit B6 ( Pyridoxin ) 40 , Acyclovir Skin Cream 5% Tube Of 5 Gm , Povidone Iodin Oint , Tab Haloperidol 0.25 Mg , Calamine + Diphenhydramine Hydrochloride Lotion , Tab Piracetam 400 Mg , Tab Biotin , Prednisolone Eye Drops 1 % , Tab Aceclofenac 100 Mg , Syp Haloperidol , Fluconazole Oint , Tab Isotretinion 20Mg , Tab Eltroxine 88Mcg , Nepafenac Eye Drop , Tab Amlodipine 2.5 Mg , Hypromellose ( Lacrigel ) Oint , Nitroglycerine, / Glyceryl Trinitrate 2.6Mg, Tab , Milk Of Magnesia 11.25 Mg, Liq Paraffin 3.75 Mg Suspension Bott Of 100Ml , Inj Vit B1, B6 , B12 And Calcium Pantothenate Amp Of 2 Ml ( Neurobion ) , Inj Vincristcin , Inj Depometrol , Hydroxyzine 10Mg, Tab , Tab Lacosamide 100 Mg , Sulphacetamide 20%Eye Drop , Inj Methylcobalamine , Syp Disodium Hydrogen Citrate ( Alkacitran ) Jar Of 5 Ltr , Dressing Medicated Waterproof , Suction Catheter , Moxifloxacin+Dexamethasone Eye Drop , Pp Crystals , Tess ( Triamcinolone Acetonide + Choline Salicylate ) Gel ( Ulsore, Mouth Ulcer ) , Isosorbide Mononitrate 10Mg, Tab , Corn Caps ( Pkt Of 4 ) , Inj Lignocain 2% , Chloromphenicoleye Apps , Dexamethasone 0.1% Eye Drops , Inj Haloperidol 5 Mg / Ml
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
34.
Educational and Research Institute #9113446 Technical Bid
Tender For Supply and Installation of Lab for Health Care for IX-XII (as per CBSE /SSC Requirement)- 1 Arduino Uno Made In Italy ATmega328P - 8 bit AVR familyMicrocontroller, equivalent or better. Operating Voltage: 5V Digital I/O Pins: 14 (of which 6provide PWM output) PWM Digital I/O Pins : 6 Accessories : Case shellenclosure, compatible USB cable (length - 6 inch or more) 2 Arduino Nano Made In Italy ATmega328P - 8 bit AVR familyMicrocontroller, equivalent or better. ConsumableOperating Voltage: 5VDigital I/O Pins : 14 (of which 6provide PWM output)Analog Input Pins : 8Accessories : Compatible USB cable ( length -6 inch or more) 3 Arduino Mega Made In Italy AT mega 2560P - 8 bit AVRfamily microcontroller, equivalent or better. Operating Voltage: 5V Digital I/O Pins : 54 (of which 6provide PWM output) Analog Input Pins: 16 Accessories: Case shell enclosure, Compatible USBcable ( length -6 inch or more) 4 Raspberry Pi 4 Model B RASPBERRY PI 4 MODEL B,equivalent or betterBroadcom 2711, 64-bit quad-core Cortex-A72 processor, 4GB RAMTrue Gigabit Ethernet port, 2 x USB 3.0 “Super-Speed” ports802.11b/g/n/ac wireless LAN (2.5 GHz & 5GHz) Bluetooth 5.0Dual micro-HDMI ports, 4K UHD video H.265 decode (4kp60)H.264 decode (1080p60)OpenGL ES 1.1, 2.0, 3.0 graphics PoE capable 5V3A USB-C power supply required 5 Breadboards & Mini Breadboard Solderless 400 pin breadboard 6 Breadboards & Mini Breadboard Solderless 800 pin breadboard 7 Breadboards & Mini Breadboard Self-Adhesive Proto Shield 8 General Purpose solderable BoardFR2 A Grade Material (140 x 90 mm) 9 General Purpose solderable BoardFR2 A Grade Material (80 x 55mm) 10 Berg StripsFemale Berg Strip, 2.54mm pitch, 40 pin single row, breakable pin 11 Berg StripsMale Berg Strip, 2.54mm pitch, 40 pin single row, breakable pin 12 16x2 LCD displayDot matrix LCD display. 16 characters X 2 lines. I2C 13 USB CablesUSB Cable Set (A to B, 12 inch or more) 14 USB CablesUSB Cable Set (Mini, 12 inches or more) 15 Battery9-12V 2000 to 2500 mAhrechargeable battery with 2 chargers. Equivalent or better 16 Resistor KitOne kit contains - 30 carbon film resistors of 20 different resistance values each assorted, packaged together and labelled.Wattage: 0.125W to 1WValues: 0O, 1.5O, 4.7O, 10O,47O, 100O, 220O, 330O, 470O,680O, 1kO, 2.2kO, 3.3kO,4.7kO, 10kO, 22kO, 47kO,100kO, 330kO, 1MO 17 Capacitor KitOne kit contains - 20 electrolytic capacitors of 10 different capacitance valueseach.Assorted kit packagedtogether and labelled.Values: 10pF, 22pF, 100pF, 1nF, 10nF, 100nF, 1µF, 10µF,100µF, 1000µF 18 Linear Voltage Regulator7805, 7812,7809 19 Water PumpModuleDC12V 3W Submersible WaterPump 20 PiezoelectricPlate Normal Copper based 4 cmDiameter approx. 21 8*8 LED Matrix Module Max7219 Dot LED Matrix Module. MCU Control LED Display Module 22 Bluetooth moduleHC 05 Bluetooth moduleVoltage Rating: 5 V 23 7 Segment Led DisplayLED 4-Digit Display ModuleVoltage Rating: 2.4V to 5.5V4-Pin interface:Vcc, Gnd, Data, Clock 24 GSM Sim900 GPRS Transfer Board Micro Sim Gsm Core TTL PortModule for Arduino 25 GPS GY-NEO6MV2 new GPSmodule 26 Laser DiodeEmitter 650 nm 5V Mini Laser DotDiode Module 27 LDR Module 5mm/12mm, PhotosensitiveLDR Light Sensor Module 28 Keypad Universal 16 Key SwitchKeypad 29 JoyStick 2-axis joystick with pushbutton function 30 Active BuzzerSmall 5 volt 31 Active BuzzerBig 5 volt 32 Motor driverModule L293D, 4-Channel driver module 33 Sound PlaybackModule ISD1820 voice recordingmodule or equivalent 34 DC Plastic Gear motor withWheel 12V, 150RPM, Side Shaft BO (Battery operation) Motor 35 Node MCUESP 8266I2C, 1 wire, plug and play 36 WeMos D1 R2WeMos D1 R2 with WiFi ESP8266Operating Voltage: 5V 37 Vibrating MotorWeight: 10 GramsOperating Voltage: 1.5 to 3V 38 AlligatorConnectors Multi-Colour AlligatorConnectors - 12 inch 39 Battery clipswith DC Jack 9-volt battery clips with DCJack 40 Hook-up Wires Red & Black set 100 Meterseach 41 Jumper CableMale-Male 42 Jumper CableMale-Female 43 Jumper CableFemale-Female 44 RGB LEDs Regular 5mm 3-5 volt Range 45 LEDs (Red) Regular 5mm 3-5 volt Range 46 LEDs (Green) Regular 5mm 3-5 volt Range 47 LEDs (Blue) Regular 5mm 3-5 volt Range 48 LEDs (Yellow) Regular 5mm 3-5 volt Range 49 LEDs (White) Regular 5mm 3-5 volt Range 50 Timer IC - LM 555LM 555 Timer IC.Voltage range - 4.5V to 16V 51 Atmega16u28 bit microcontroller Individual IC (DIP).Voltage range: 2.7V to 5.5V.Operational Range: -40°C to+80°C 52 Diodes and Transistors KitOne Kit Contains - 25 Assorted Basic Diodes of 4 differenttypes each.Types: NPN Transistor - 2N3904, BC547 PNP Transistor- 2N3906, BC557 Silicon Diode- 1N4148, Power Diode - 1N4004/4001.Equivalent or better.Wattage: 1W, Current rating:1AAssorted kit packagedtogether and labelled. 53 Button Switch SetOne Kit Contains - 100 buttonsof different types.Types: Push, toggle, rotary,selector and slide switch.Assorted kit packagedtogether and labelled. 54 Capacitative touch ModuleMPR 121 with I2C.Voltage Range:2.5V to 3.6V DC. 55 Capacitative Touch Switch ModuleDigital Capacitive touch switchmodule -TTP223BVoltage Range: 2V to 5V DC. 56 IR Proximity Sensors, Obstacle avoider sensor moduleLM393Detection distance:2 - 30 cmDetection angle: 30 - 40° 57 Triple Axis Magnetometer3-Axis Magneto resistiveSensorsI2C Digital InterfaceIntegrated 12-bit ADCRange of -8 to +8 Gauss160 Hz Maximum o/p rate 58 Humidity SensorOperating range:20 – 95 % RHTemperature: 0 - 60 CelsiusPower supply:1.5V AC (Max sine)Operating frequency:500Hz - 2kHz 59 MQ SeriesMQ - 2 Smoke DetectionMQ-3 Alcohol - Ethanol SensorMQ-4 Methane Natural GasSensorMQ-5 Methane Liquefied GasSensorMQ-6 Liquefied Petroleum GasSensorMQ-7 High Sensitivity CO Carbon Monoxide SensorDetectorMQ-8 Hydrogen Gas SensorMQ-135 Air Quality Sensor 60 MQ SeriesMQ-3 Alcohol - Ethanol Sensor 61 MQ SeriesMQ-4 Methane Natural Gas 62 MQ SeriesMQ-5 Methane Liquefied GasSensor 63 MQ SeriesMQ-6 Liquefied Petroleum GasSensor 64 MQ SeriesMQ-7 High Sensitivity CO Carbon Monoxide SensorDetector 65 MQ SeriesMQ-8 Hydrogen Gas Sensor 66 MQ SeriesMQ-135 Air Quality Sensor 67 IR transmitter/TSOP 1738ReceiverSwitching rate: 38 KHzVoltage Rating: 5V 68 Ultrasonic Sensor Module HC-SR-04 orCompatibleWorking Voltage - DC 5VWorking current - 15 mAWorking Frequency - 40 HzRange - 1 cm to 4 mEffectual Angle - <15°Measuring Angle - 30°Resolution - 0.3 cm 69 Triple Axis accelerometer-3-axis sensingSmall, low profile package4 mm × 4 mm × 1.45 mmLFCSPLow Power: 350 µA (typical)Single-supply operation: 1.8 Vto 3.6 VTemperature stability 70 PIR Motion Detector ModuleHigh digital pulse whenmotion detectedLow digital pulse when idle/no motion detectedSensitivity range (up to 6 m)Power supply: 5V – 12V 71 Pulse Rate Heart Sensor Pulse Rate Sensor Finger Based (finger or earlobe)Working voltage 3-5V 72 Relay Module 5V 10A - 2 Channel Relay Module. Compatible with Arduino. 73 Relay Module 5V 10A - 1 Channel Relay Module. Compatible withArduino. 74 Big Sound microphone module Large Electret capsule sound module 75 Soil Moisture Sensor moduleFC-28 with LM293 comparatorOperating Voltage: 3.3V to 5V. 76 Touch Sensor Capacitive Touch SensorModule. TTP22X series. Voltage Range: 2.4V to 5.5V 77 Metal Touch Sensor Module KY-036 or equivalent metal touch sensor module 78 Rain Drop Sensor Rain Sensitive, Rain DropDetection Sensor Module. Voltage Range: 3.3V to 5.5V. 79 Flex Sensor Flex Sensor. Size - 2.2 Inches 80 Temperature Sensor LM35 Full range temperature sensor. Voltage Range: 4V to 30V. Error: ±0.5°C 81 Temperature and humidity sensor moduleDHT 11Voltage Range: 3V to 5V 82 Force Pressure Sensor Force sensitive resistor with a square, 1.75x1.5 sensing area 83 ColourRecognition Sensor TCS3200 Colour Recognition Sensor 84 Water Flow Sensor Arduino Compatible Water flow sensor. 5V DC Input. 85 Sound Sensor Sound Sensor Module, Microphones module 86 IR Sensors Array module for Line Following8 IR Sensors Array module forLine FollowingOperating Voltage: 5V 87 Power Bank 10000 mAh 5-volt Power Bank 88 RFID Reader –TagsCurrent :13-26mA / DC 3.3VIdle Current :10-13mASleep Current<80uAPeak Current<30mAOperating Frequency:13.56MHz<30mARead range between 20 cm to 1 m 89 RF Modules Tx & Rx 315 MHz ASKFrequency Range: 433.92/315MHzSupply Voltage: 3 – 6 VOutput: 4 – 16 DbmLow power consumptionEasy application 90 Stepper motor with Driver board 28BYJ-48 ULN2003 5V StepperMotor + ULN2003 Driver Board 91 DC motor 12V DC Gear 150 RPM 92 Servo motorsPosition Servo Angle basedMetal Gear 93 Servo motorssmall Servo Metal Gear, 1.8Kg-cm(4.8volt), 2.2 Kg-cm(6v) 94 Servo motorsContinuous Metal Gear Servo360, 9.4 kg-cm(4.8volt) 95 Servo motorsSmall Servo Plastic Gear, Voltage – 5v 96 150 RPM BO(Battery operated)DC Motor 150 RPM BO Motor 97 L298P MotorDriver L298P Motor Driver Shield orrelative Driver Shield 98 Servo MotorTester CCPM 3 channel Servo Tester 99 Robotics DIY Kit Robotics DIY kit with programmable intelligentbrain/brick. 100 Mechanical (Modular)Construction kit Metal/plastic mechanical construction kit compatiblewith electronic equipment. 101 Drone KitEducational PurposeAerospace KitAutomobile KitBio-Medical KitAgri-Tech KitWater/Sanitation KitBio Tech KitOther Potential STEMApplication Kit 102 Educational Purpose 103 Aerospace Kit 104 Automobile Kit 105 Bio-Medical Kit 106 Agri-Tech Kit 107 Water/ 108 Sanitation Kit 109 Bio Tech Kit 110 Other Potential STEMApplication Kit 111 3in1 3D Printing Kit and tools 3D Printing + CNC Cutting + Laser Engraving MachinePrinter Type:FDM (Fused Deposition Modelling),Molding Technology: FDM fused deposition moldingMolding Size: 200x200x200mmFile Format: STL, OBJ, AMFSupporting Material: 1.75mm diameter PLA, ABS, TPU, PVANozzle Diameter: Standard 0.4 mm, can be in 0.6 mm,0.8 mm,1.0mm,1.2 mmHot Bed Temperature: =100°C CNC CuttingWorking Size: 200x200mmSupport Materials: wood, paper, PCB, plastic, etcFile Format: JPG, JPEGSpindle Speed: 4800 rpm maxStandard Cutter Size: Tungsten Alloy Milling CutterLaser EngravingWorking Size: 200x200mmSupport Materials: wood, paper, plastic, leather, etcFile Format: JPG, JPEGLaser Power: less than 0.5wQuality Anti-bacterial/fungal Cover.Repair Kit - with sparesprings, screws, keys, tweezers, etc. 112 Dedicated UPS/Power back up Dedicated UPS/Power Back up with 2-hour battery backup. 113 Filament for 3D printer Compatible 1000 Grams Filament in 5 different coloursWhite PLA -8Marble PLA-2Wood PLA - 2Glow in darkPLA on- 2Pink – 2Blue – 2Orange – 4Grey – 2 Black 2Red -2Green 2 114 Filament Storage Box Compatible Filament storage box 115 Set of Arts & Crafts Accessories – e.g.- stationary items and basic prototyping materialCardboard 116 Set of Arts & Crafts Accessories – e.g.- stationary items and basic prototyping material Foam core boards 117 Set of Arts & Crafts Accessories – e.g.- stationary items and basic prototyping material 20m spool of thick stringsvarious colour 118 Set of Arts & Crafts Accessories – e.g.- stationary items and basic prototyping material Rubber band 119 Set of Arts & Crafts Accessories – e.g.- stationary items and basic prototyping material Popsicle sticks 120 Set of Arts & Crafts Accessories – e.g.- stationary items and basic prototyping material Wood glue – 500 ml 121 Hacksaw Frame Size: 12 inchesMaterial – flat steel 122 Hacksaw blades Size: 12 inchesHigh carbon steel (HCS) 123 Mini Hacksaw Frame Size: 6 inchesFlat steel 124 Mini Hacksaw blades Size: 6 inchesHigh carbon steel (HCS) 125 Pliers: 4.5-inch size External Straight Nose Circlip Plier 126 Pliers: 4.5-inch size External Straight Long Nose Plier 127 Pliers: 4.5-inch size External Straight Combination Mini Plier 128 Pliers: 4.5-inch size External Straight Wire stripping pliers 129 Pliers: 4.5-inch size External Straight Bent nose plier 130 Pliers: 4.5-inch size External Straight Needle nose plier 131 Tweezer Set 6 Pc Non-Magnetic Tweezer SetSize - 6 inches 132 Ball Peen Hammer Ball Peen Hammer Weight - 0.75kg 133 Steel Shaft Claw Hammer Claw Hammer Steel Shaft Weight - 0.75kg 134 C-Clamp Metal Clamp: 3-inch size 135 Flexible Extension Shaft 150 mm length, 10mm chuck size 136 Allen Key Set 10 Piece Ring Imperial Allen Hex key 137 Drill Machine Set Drill Machine with accessories Hammer/Screw and clockwise/anticlockwise modes.Power: 500WChuck capacity - 1 to 10 mmDrill Bits Complete set Masonry –4, 5, 6, 8, 10 mm. Metal- 2, 3, 4, 5, 6 mm.Wood – 4, 5, 6, 8 mmSpirit level – Horizontal, vertical , slantingAdjustable knife and Wrench 138 Drilling Workstation Drill Press, Drill Holder and Rotary Tool, Compatible with Drillingmachine provided 139 Spanner Set 12-piece combination Spanner SetRange - 4 mm to 30 mm 140 Vice Normal Table top vice 141 Precision Screw Driver Set 6 Piece Precision Screw Driver SetTypes: PH0, PH1, Flat head - 1.4mm, 2mm, 2.4mm, 3mm 142 Wrench Adjustable UniversalWrench 143 Wire Strippers Wire Stripper Cutter PlierWith Spring -26x6x20 cm (LxWxH) 144 Screwdriver set 40 pc Multi-purpose screwdriver set 145 RotaryMultitool Set Rotary multitool with all cutting, grinding, polishing, engraving and drill bits.109-in-1 woodcarving drilling grinding drill tuner• Voltage:220-240V~50/60Hz• Input power:130W• No-load speed:10000-35000rpm• Collet size:3.2mm/2.3mm• Variable speed control• With 1pcs flexible shaft• With 109pcs accessories• With 1set extra carbon brushes 146 Air Blower 500 W or more. Variable speed blower 147 Drill Bit Set High Quality 13 Pcs HSS Drill Bits Set for Wood, Iron, Aluminium, Plastic etc. 148 File set 6 pc file setWorking length - 6 inch (different type) 149 Mini File set 6 pc mini file set Working length - 3 inch (different type) 150 Flexible Cutting Mat A3 Size with Marked Pattern and Grids (18 X 12) 151 Plastic Storage Drawer/Organiser Number of Drawers: 60 or equivalentDrawer size (l*w*d) (inch): 2*2*5 152 Pegboard Pegboard System to mount tools on wall with attachments (hooks etc.)Size: 3ft*2ft 153 Hot glue gun Works with standard 0.5- inch glue sticks.100Watts (220-240w)Temperature - 230 to 280 degree Celsius. 154 Digital Oscilloscope RIGOL or similar No genericMinimum Bandwidth: 50 Mhz.Minimum number of channels: 2 channels. Sample Rate: 1Gsa/s With inbuilt waveformFunction generator. 155 Soldering KitVariable Wattage of Soldering Iron: 15-30watts/230 voltsSoldering Iron Temperature Range: 280°C to 450°CDe-Soldering Pump, Soldering Flux (Paste) 100 grams,DE-soldering Copper Braid (Solder Wick) -1.5m*2mmCompatible Soldering Tip- Bevel, Chisel, Conical - 5 each per kit.Soldering Wire: 20/22 AWG soldering Wire with rosin core flux (100 Grams) 156 Adapters DC power Adapter with5V, 2A 157 Adapters DC power Adapter with12V, 2A 158 Electric Screw Driver Set (Cordless) Multipurpose Electric screwdriver set.Accessories - Compatible bitsMode - Wireless Battery - Li-ion 3.6V orequivalent with charging dockTorque hard : 5 NMTorque Soft : 2.5 Nm 159 Dual Temperature Heat Gun 1800 W Dual Temperature Heat Gun 160 Soldering Helping hand Specifications: Adjustable crocodile holding clamps/clip. Soldering iron holder. LED light.Magnifying lens. 161 Projector Type: No Optical Zoom / Focus (Manual)Focal Length:16.70 mmF-number:1.44Zoom:1.44 - 1.95 (Wide to Tele) RatioThrow Ratio Range:1.00 – 1.35 (Digital Zoom)3LCD technology for equal white & colour light outputNative XGA resolution and 4:3 performanceLong lamp life up to 12,000 hours*2 in ECO modeEasy setup and positioning flexibilityHDMI connectivity 162 Laptop • 12th Generation Intel® Core™ i7 processor• Windows 11 Home • 39.6 cm (15.6) diagonal, FHD (1920 x 1080), 144 Hz, 9 ms response time• NVIDIA® GeForce RTX™ 3050 Laptop GPU (4 GB GDDR6 dedicated)• 1 TB PCIe® Gen4 NVMe™ TLC M.2 SSD• 16 GB DDR4-3200 MHz RAM (2 x 8 GB)• Weighs: 2.29 kg 163 DesktopSpecificationValueProcessor Make IntelProcessor Generation i7 or higherNumber of Cores per Processor 12 or higherProcessor Base Frequency (GHz) 2.5 or higherCache (MB) 12 or higherGraphic card capacity Dedicated 2 GB or higherOperating System (Factory Pre- Loaded) Windows 11OS Certification Microsoft windowsType of RAM DDR5RAM Size (GB) 16 or higherRAM Speed (MHz) 4800 Mhz or higherRAM Expandability up to (using spare DIMM Slots in GB) 128 or higherType of Drives used to populate the Internal Bays SSDCapacity of each HDD (TB) 1 TB or higherWireless Connectivity Yes (inbuilt)Type of Wireless Connectivity Wi-Fi 802.11acNumber of Ethernet Ports 1Type of Ethernet Ports 10/100/1000 on board Integrated Gigabit PortLED Backlit Monitor Size (INCHES) 23.8 or higherMonitor Resolution (PIXELS) 4096×2160On Site OEM Warranty (Year) 5 or higherPort Connectivity DP port -1, HDMI -1, Audio out Port with microphone support, PCIe slot -2, USB port – minimum 4 (out of this minimum 2 USB 3.1), USB port – 2 on front, Type C port -1, M2 PCIeslot – 1Keyboard Wired Keyboard from the same OEM as Desktop with embossed OEM LogoMouse Wired Mouse from the same OEM as Desktop with embossed OEM LogoPower Supply 90% Efficient Power SupplyCompliance RoHS, Energy Star, EPEAT Gold Registered, TCO Certified 164 Return measuringTape Return measuring tape5Mx19mm 165 Stainless Steel Rule Stainless Steel 12” / 150mm Rule 166 Digital VernierCalliper 150 mm / 6” DigitalVernier Calliper 167 Spirit Level 12” Spirit Level 168 Digital Pen electricTester Voltage tester 169 Digital Multi MeterClam MeterDigital Multi Meter Voltage Current Resistance-7 functions + 19 ranges to cover DCvoltage 200mV to 1kV,AC voltage 200 V - 750 V,DC current 200 µA - 10 AResistance 200 -2 M Ohm and Transistor & diodetest. 170 DIY Paper Microscope DIY Paper microscope. Magnification range -100x to 2000x 171 TelescopeAll glass opticalcomponentsAltazimuth mount suitable for terrestrial andastronomical useminimum 700 mm focallength 172 Sewing KitSemi-Automatic SewingmachineStraight stitchConsumables - 2 set ofassorted needles and 10- colour spool set. 173 Glue Sticks 11 mm x 200mm Hot Melt Glue Stick 174 Nuts and Bolts and screw Specs - M4X12MM M4X20MM M5X16MMM5X25MM M6X20MM 175 Cable TieSmall Cable Tie Pack -Pack of 100 176 Cable TieMedium Cable Tie Pack - Pack of 100 177 Cable TieBig Cable Tie Pack - Packof 100 178 Sand Paper Grit Values - 80, 100,120, 200, 300.5 Nos of each 179 Power Strip Adaptors Standard Quality Extension with 5Amp safety fuse.5 or more sockets in each extension.5-meter length of each extension. 180 Bulb Holders Regular Hanging Bulb holder 181 Two Pin Plug Regular Two Pin Plug 182 Electric Wires 1.5 Sq mm wire spool copper 183 USB TO DCjack cable USB to DC jack cable for Battery bank 184 First-Aid Kit Standard Medical First Aid kit in portable container. 185 Fire extinguisher(handy units) Powder Type Fire Extinguisher 2KG 186 Safety goggles (with/ withoutLED torch) Polycarbonate Safety gogglesClear lens with no tintCover half upper face with adjustable strap 187 LED Bulb 9W 188 Laser safety glasses Optical Density 6 Bosch Laser Glasses 189 Safety Gloves Pairs Latex Coating Gloves (Medium Size) 190 Anti-static safe discharge wrist band Current limiting register 1 m Ohm +/- 5 %Electrostatic discharge time -<0.1 second 191 Safety Mask Filtering efficiency ranging 80 percent when tested against 0.3-micron sodiumchloride particle 192 Safety shoes • Lining: Moisture wicking breathable fabric lining• Steel Toe: Can withstand an impact of over 200 J• Sole: Double density directly injected PU sole. Care Instructions : Clean with Damp Cloth, Black Polish can be used• Oil and acid resistant, anti-static• Grey Spacer Lining ; Antistatic ; Lace-up model with D rings 193 Safety apron• Safety Uniform• Cotton• Industrial• All sizes• Color- As per requirement• Pattern- Plain 194 Safety Halmet • Safety Helmet• Colour ?Yellow• Material ?High Density Polyethylene (HDPE)• Specification Met ?Isi certified• Closure Type ?Ratchet• Department ?Unisex-Adult• Weight - 300 g approx.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
35.
Public Administrative Department #9057046 Technical Bid
Sealed Quotations are hereby invited from reliable and bonafide service provider for supplying the services as specified below for the Scheme namely Drinking source Repair Under CFCG/SFC Programme. , Weight Washer , Plunger , Mark 2 Chain , Axel , Nut & Bolt , Bearing , Top Cap , Head Of Mark2 Tubewell , Adopter , Hendle , Supply Of Pvc Pipes & Fittings Schedule 80 (Medium Duty) Conforming To Astmd - 1785 And Threaded To Match With Gi Pipes As Per Is : 1239 (Part - I).(A) Pvc Pipes (Dia)(P-13,Item-19(Iii)) I)15 Mm , Supply Of Pvc Pipes & Fittings Schedule 80 (Medium Duty) Conforming To Astmd - 1785 And Threaded To Match With Gi Pipes As Per Is : 1239 (Part - I).(A) Pvc Pipes (Dia)(P-13,Item-19(Iii)) Ii)20 Mm , Supply Of Pvc Pipes & Fittings Schedule 80 (Medium Duty) Conforming To Astmd - 1785 And Threaded To Match With Gi Pipes As Per Is : 1239 (Part - I).(A) Pvc Pipes (Dia)(P-13,Item-19(Iii))Ii)25 Mm , Supply Of Pvc Pipes & Fittings Schedule 80 (Medium Duty) Conforming To Astmd - 1785 And Threaded To Match With Gi Pipes As Per Is : 1239 (Part - I).(A) Pvc Pipes (Dia)(P-13,Item-19(Iii))Ii)32 Mm , Supply Of Pvc Pipes & Fittings Schedule 80 (Medium Duty) Conforming To Astmd - 1785 And Threaded To Match With Gi Pipes As Per Is : 1239 (Part - I).(A) Pvc Pipes (Dia)(P-13,Item-19(Iii))Ii)40 Mm , Supply Of Pvc Pipes & Fittings Schedule 80 (Medium Duty) Conforming To Astmd - 1785 And Threaded To Match With Gi Pipes As Per Is : 1239 (Part - I).(A) Pvc Pipes (Dia)(P-13,Item-19(Iii))Ii)100 Mm , Supply Of Pvc Pipes & Fittings Schedule 80 (Medium Duty) Conforming To Astmd - 1785 And Threaded To Match With Gi Pipes As Per Is : 1239 (Part - I).(A) Pvc Pipes (Dia)(P-13,Item-19(Iii))Vii)Redusing Soket 100 X 40 , Supplying Pvc Strainer Of Approved Make With Adapter Conforming To I.S.12818 Specifications.(P-52,Item-06)I) 40 Mm , Supplying Pvc Strainer Of Approved Make With Adapter Conforming To I.S.12818 Specifications.(P-52,Item-06) I) 80 Mm , Supplying, Fitting And Fixing Steel Cutter Piece Upto 450 Mm Long With Sockets.(P-53,Item-09) I) 40 Mm , Supplying, Fitting And Fixing Steel Cutter Piece Upto 450 Mm Long With Sockets.(P-53,Item-09)Ii) 75 Mm , Supplying, Fitting And Fixing 65 Mm Dia. Deep Well Brass Cylinder With Necessary Fittings And Accessories.(P-54,Item-15) , Supplying, Fitting And Fixing 15 Mm Dia. Galv. M.S. Connecting Rod With Sockets.(P-54,Item-16) , Packing The Annular Space Between The Outside Of The Tube Well Pipes & Strainers And The Bore With Pea Size Washed Gravel Of Approved Quality Having Size From 2 Mm To 5 Mm Or The Size Approved By The Engineer-Incharge Including Cost Of All Materials Labour And Equipment Complete.(Note: Initial 6 M. Of Annular Space Between The Housing Pipe And The Bore Should Not Be Shrouded With Pea Size Gravel To Avoid Contamination With Surface Water.)(P-55,Item-24) , Taking Out Pipes Of Existing Tube Well Including Strainer Etc. Complete For Portion Of Length: (P-56,Item-01)(A) Upto 20 Metre Below G.L.(I) 40 Mm Dia. , Taking Out Pipes Of Existing Tube Well Including Strainer Etc. Complete For Portion Of Length: (P-56,Item-01)(A) Upto 20 Metre Below G.L.(Ii) 80 Mm Dia. , Taking Out Pipes Of Existing Tube Well Including Strainer Etc. Complete For Portion Of Length: (P-56,Item-01)(A) Upto 20 Metre Below G.L.(Iii) 100 Mm Dia. , Taking Out Pipes Of Existing Tube Well Including Strainer Etc. Complete For Portion Of Length: (P-56,Item-01) (B) Beyond 20 Metre Below G.L. (I) 40 Mm Dia. , Taking Out Pipes Of Existing Tube Well Including Strainer Etc. Complete For Portion Of Length: (P-56,Item-01) (B) Beyond 20 Metre Below G.L. (Ii) 80 Mm Dia. , Taking Out Pipes Of Existing Tube Well Including Strainer Etc. Complete For Portion Of Length: (P-56,Item-01) (B) Beyond 20 Metre Below G.L.(Iii) 100 Mm Dia. , Supplying, Fitting And Fixing Brass Cylinder Parts.(I) Brass Plunger Complete , Supplying, Fitting And Fixing Brass Cylinder Parts.(Ii) Brass Plunger Complete Without G.I. Rod , Supplying, Fitting And Fixing Brass Cylinder Parts.(Iii) C.I. Top Socket , Supplying, Fitting And Fixing Brass Cylinder Parts.(Iv) C.I. Bottom Socket , Supplying, Fitting And Fixing Brass Cylinder Parts.(V) 65 Mm Brass Tube (Both Ends Threaded) , Labour For Boring Tube Well Of Required Dia. By Water Jet System Through Any Type Of Soil Strata Including Hire And Labour Charges For Boring Pipes, Scaffolding, Tools And Plants As Necessary And Taking Out Them And Lowering Pipes, Strainers , Blind Pipe Etc. And Fitting And Fixing The Same Complete Including Bucket Washing And Other Incidental Works In The Connection. The Tube Well Should Have A Minimum 50 Mm Gap In Between The Outside Of The Tubewell Pipe And The Bore.(A) For Depth Upto 150 Metre.(P-49,Item-01)(I) 40 Mm Dia. Boring Etc. , Labour For Boring Tube Well Of Required Dia. By Water Jet System Through Any Type Of Soil Strata Including Hire And Labour Charges For Boring Pipes, Scaffolding, Tools And Plants As Necessary And Taking Out Them And Lowering Pipes, Strainers , Blind Pipe Etc. And Fitting And Fixing The Same Complete Including Bucket Washing And Other Incidental Works In The Connection. The Tube Well Should Have A Minimum 50 Mm Gap In Between The Outside Of The Tubewell Pipe And The Bore.(A) For Depth Upto 150 Metre.(P-49,Item-01)(I) 80 Mm Dia. Boring Etc. , Supplying P.V.C. Water Storage Tank Of Approved Quality With Closed Top With Lid (Black) - Multilayer(P-37,Item-06)(A) 500 Litre Capacity , Supplying P.V.C. Water Storage Tank Of Approved Quality With Closed Top With Lid (Black) - Multilayer(P-37,Item-06) (B) 1000 Litre Capacity , Cleaning And Disinfecting Upto 2000 Litre Water Tank Including Masonryreservoir(P-40,Item-14) , Supplying, Fitting And Fixing Bib Cock Or Stop Cock.(E) Ptmt (Polytetra Bib Cock / Stop Cock ( Prayag Or Equivalent) , Supply,Fitting & Fixing New Elect.Sub Marsal Sturter.(As Per Eic) , Repair Of Elect. Sub Marsal Pump Including Removing And Fitting & Fixing , Supply Of Elect. Sub Marsal Capacitor (Removing & Fixing) , Supply And Repair Ofold Sub Marsal Sturtera)Switch , Supply And Repair Ofold Sub Marsal Sturter B)Capasitor , Supply And Repair Ofold Sub Marsal Sturter C)Ampear Meter , Supply And Repair Ofold Sub Marsal Sturterd)Mcb , Supply And Repair Ofold Sub Marsal Sturter E) Voltameter , Supply And Fixing Magnet Coil , Removing Old Solar Controlar And Repair,Fitting & Fixing , Supplying And Installation Of1 Nos Frp Vesel (12X48) (Tata/Pentair)Of Filtering Media Treated Sand-Gravel- Activated Carbon/ Charcol As Per Necessary , Supply And Fixing Jambbo Filtter . , Removing Old Filter Media And Supply And Layin New Filter Mediaa) Pabbles (1/2) , Removing Old Filter Media And Supply And Layin New Filter Media B) Pabbles (1/4) , Removing Old Filter Media And Supply And Layin New Filter Media C)Medium Treated Sand , Removing Old Filter Media And Supply And Layin New Filter Media D)Katalox , Removing Old Filter Media And Supply And Layin New Filter Mediae)Carbon , Service Chargea) Cleaning Solar Panel , Service Charge B) Cleaning Water Tank , Service Charge C) Hoisting And Lowaring Sub Marsible Pump , Service Charged) Cleaning Of Filter Media(Back Wash) , Solar Module: Supply, Transport, Installation And Commissioning Of Isi Marked Solar Modules As Per Following Specification: 1. Cell: Digenous Mono Crystalline Silicon Spv Cells 2. Solar Module: Monocrystalline Cell With Perc Technology / Module With Bifacial Cell. 3. Standards: Isi Marked As Per Is 14286 And Having Certification Of Iec 61853(1), 61730(1&2), 61710 4.Modules Must Qualify To Is 170210 (Part 1) 5.Min. Efficiency: 19.5%. 6. Fill Factor: More Than 75%. 7. Module Wattage Mismatch In The Spv Array: Within ±3% 8. Wattage Output Warranty:Should Not Be Less Than 90% At The End Of 10 Years And 80% At The End Of 25 Years. 9.The Power Output Of Individual Pv Modules Used In The Pv Array, Under Stc: Minimum 300 Wp. Necessary Test Certificates Also To Be Supplied. For Detail Information Please See Cl. No. 2.1 Of Technical Specification. , Power Conditioning Unit With Enclosure:Supply, Transport, Installation And Commissioning Of Solar Power Conditioning Unit Consisting Of Following Components And Features: 1) Variable Frequency Drive With Inbuilt Mppt, Voltage Range Suitable For Operating Pump-Motor Set Of 1Hp To 20 Hp, Detail Mentioned In Cl.6.1 2) Power Input: Ac/ Dc Source For 1Hp, 2Hp And 3Hp.4) Incomer: Dc Mcb 2 Pole 16 Amp Upto 5 Hp, 25 Amp For 7.5Hp And 10 Hp, 40 Amp For 15 To 20 Hp As Per Is/Iec 60947-2 5) Incomer: Ac Mcb 4 Pole 16 Amp Upto 5.0 Hp, 25 Amp For 7.5Hp And 10 Hp, 40 Amp For 15 To 20 Hp As Per Is/Iec 60947-2 6) Type Ii Dc Spd Of 40 Ka. 7) Type Ii Ac Spd Of 40 Ka For Ac/ Dc Or Hybrid Input. 8) Dual Input (Solar/Grid) 25 Amp Changeover Switch For 5Hp And 7.5 Hp, 40 Amp. For 10 Hp, 63 Amp For 15 To 20 Hp. 9) Reverse Protection Diode 1600 Vdc With Heat Sink.10) Data Logger.11) Remote Monitoring System.12) Should Have Built -In Emc Filters.13)Ip 65 Glands For Cable In And Out.14) Min. Ip 54 Enclosure.For Detail Features, Protections, Rms, Communication Architecture, Security, Data Storage, Tolerance Of Various Parameters, Standards To Be Qualified, Etc. Please Refer To Cl. 6.1 Of Technical Qualification. A) For 1 Hp Capacity Pump-Motor Set With Ac-Dc Input , Cable And Accessories : Supplying, Fitting And Fixings Of Uv Rated Copper Cable Laid Inside Hdpe Conduit And Other Accessories As Per Followings With Necessary Connection With The Solar Pv Module, Mppt Etc. 4.0 Sq Mm Single Core Multi Studs 5M(For 1Hp/2Hp/3Hp) & 20M(For 5/7.5/10/15/17.5/20 Hp) Ii. Lugs, Hdpe Pipe, Flexible Pipe, Saddle, Cable Tie Etc.A) For 1 Hp/2 Hp/3Hp Per Structure , 125 Mm. Thick Brick Work With 1St Class Bricks In Cement Mortar (1:4) In Ground Floor. , Plaster (To Wall, Floor, Ceiling Etc.) With Sand And Cement Mortar Including Rounding Off Or Chamfering Corners As Directed And Raking Out Joints Including Throating, Nosing And Drip Course, Scaffolding/Staging Where Necessary (Ground Floor).[Excluding Cost Of Chipping Over Concrete Surface](B) 15 Mm Thick Plaster(1:6) , Neat Cement Punning About 1.5Mm Thick In Wall, Dado, Window Sill, Floor Etc. Note:Cement 0.152 Cu.M Per100 Sq.M. , Brick Work With 1St Class Bricks In Cement Mortar (1:6) B)In Superstructure, Ground Floor
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
West Bengal View Result →
36.
Educational and Research Institute #8994161 Technical Bid
Disposal Of Unserviceable / Condemned Items Electronic Items / Electrical Items / Equipments Including E-Waste - Pco Printer Tpye , Pcopay Phone, Cpd Pco Monitor , Push Button Telephone , Wall Mounted Push Button Telephone, Telephone Module Gcel- 504, 10 Memory Push Button , Electronic Push Button Phone, Telephone Instrument Siemens , Telephone Instruments , Fire Extinguisher , Safex Make Water Co2 Safex Refill Dcp - 1 Kg Do - 5 Kg Refill Co2, 3.2 Kg Do - Co2, 4.5 Kg Safex Refill Foam 9 Ltr Halon 500 Sm Fire , 1.5 Ton Window A.C. , Window A.C.- 1.5 Ton , Window A.C.- 1.5 Ton ( 180Bys ) Window A.C.- 1.5 Ton , 1.5 Ton Window A.C. , ( 180Bys ) Window A.C. 1.5T ( Blue Star ) , Window A.C. 145. Nsc / 2A / 354 / 12 / 1 ( 492801215 ) Deep Freezer With Stabilizer 146. Nsc / 2A / 399 / 11 / 3 ( 492801216 ) 20 Desert Cooler 147. Nsc / 3A / 281 / 1 / 4 ( 492801217 ) Fire Extinguisher 148. Nsc / 3A / 281 / 2 / 2 ( 492801218 ) Fire Extinguisher 149. Nsc / 3A / 281 / 2 / 3 ( 492801218 ) Fire Extinguisher 150. Nsc / 3A / 281 / 2 / 4 ( 492801219 ) Fire Extinguisher 151. Nsc / A / 311 / 4 / 1 ( 492801220 ) Safex Make Dry, Co2, Halon 1211 And Sofex Make Water Co2 152. Nsc / A / 304 / 5 / 1 ( 492800601 ) Network Typewriter M / C 153. Nsc / A / 303 / 2 / 1 ( 492800606 ) Typewriter Facit Make 154. Nsc / A / 304 / 7 / 1 ( 492800608 ) Network Electric Type- Writer Model 411 155. Nsc / A / 307 / 6 / 1 ( 492800609 ) Canon Np 1010 With Xerox Machine 156. Nsc / 3A / 222 / 15 / 3 ( 492801812 ) Chair 157. Nsc / 3A / 385 / 2 / 8 ( 492801812 ) Computer Chair 158. Nsc / 3A / 385 / 2 / 11 ( 492801812 ) Computer Chair 159. Nsc / 3A / 389 / 8 / 3 ( 492801812 ) Cane Chairs 160. Nsc / 2A / 394 / 8 / 1 ( 492801812 ) Office Chair 161. Nsc / 3A / 386 / 5 / 1 ( 492801814 ) Chair 162. Nsc / 3A / 390 / 12 / 1 ( 492801814 ) Computer Chair 163. Nsc / 2A / 391 / 8 / 17 ( 492801814 ) Computer Revolving Chair 164. Nsc / 2A / 394 / 2 / 7 ( 492801814 ) Computer Revolving Chair 165. Nsc / 2A / 399 / 6 / 6 ( 492801814 ) Computer Chair 166. Nsc / 2A / 399 / 14 / 8 ( 492801814 ) Computer Chair With Arms 167. Nsc / 2A / 400 / 16 / 2 ( 492801814 ) Computer Chair 168. Nsc / 2A / 425 / 6 / 14 ( 492801814 ) Computer Chair Revolving169. Nsc / 3A / 222 / 5 / 24 ( 492801818 ) Chairs Without Arm Chr-4 170. Nsc / 3A / 222 / 5 / 26 ( 492801818 ) Chairs Without Arm Chr-4 171. Nsc / 3A / 222 / 5 / 30 ( 492801818 ) Chairs With Arms Chr-7 172. Nsc / A / 243 / 13 / 1 ( 492801818 ) Computer Chair 173. Nsc / A / 244 / 3 / 5 ( 492801818 ) Cane Chair 174. Nsc / A / 244 / 3 / 11 ( 492801818 ) Cane Chair 175. Nsc / A / 244 / 4 / 3 ( 492801818 ) Chair Chr-18 ( Cane ) 176. Nsc / A / 244 / 4 / 10 ( 492801818 ) Chair Chr-18 ( Cane ) 177. Nsc / 3A / 381 / 6 / 1 ( 492801818 ) Chairs Armless 178. Nsc / 3A / 381 / 6 / 19 ( 492801818 ) Chairs Armless 179. Nsc / 3A / 385 / 1 / 11 ( 492801818 ) Chairs With Arms ( Ch 7 ) 180. Nsc / 2A / 426 / 5 / 8 ( 492801818 ) Godrej Chair With- Out Arm 181. Nsc / 3A / 12 / 1 ( 492801472 ) Outlet Mist Filter 182. Nsc / 3A / 12 / 2 ( 492801472 ) Outlet Mist Filter 183. Nsc / 3A / 41 / 3 / 1 ( 492801472 ) Osciloscopeceroymate 184. Nsc / 3A / 41 / 3 / 2 ( 492801472 ) Osciloscopeceroymate 185. Nsc / 4A / 48 / 4 / 1 ( 492801472 ) Microwave Oven ( Power Solo 17D ) 186. Nsc / 3A / 50 / 4 / 1 ( 492801472 ) Intel Pentium-4 Pc 187. Nsc / 4A / 54 / 7 / 1 ( 492801472 ) Spare Parts Rf Amplifier 188. Nsc / 3A / 75 / 2 / 1 ( 492801472 ) Antistatic Temperature Controlled 189. Nsc / 2A / 487 / 8 / 1 ( 492801472 ) Network Module Rs232 / Rs485 - Fp1000 190. Nsc / 2A / 487 / 8 / 2 ( 492801472 ) Network Module Rs232 / Rs485 - Fp1000 191. Nsc / 2A / 487 / 8 / 3 ( 492801472 ) Network Module Rs232 / Rs485 - Fp1000 192. Nsc / 2A / 487 / 8 / 6 ( 492801472 ) Network Module Rs485 - Fp1001 193. Nsc / 2A / 487 / 8 / 7 ( 492801472 ) Network Module Rs485 - Fp1001 194. Nsc / 2A / 487 / 8 / 8 ( 492801472 ) Network Module Rs485 - Fp1001 195. Nsc / 2A / 487 / 8 / 11 ( 492801472 ) 16 Bit Analog In- Put / Output Module -Fp110 196. Nsc / 2A / 487 / 8 / 12 ( 492801472 ) 16 Bit Analog In- Put / Output Module -Fp110 197. Nsc / 2A / 487 / 8 / 13 ( 492801472 ) 16 Bit Analog In- Put / Output Module -Fp110 198. Nsc / 2A / 487 / 8 / 14 ( 492801472 ) 16 Bit Analog In- Put / Output Module -Fp110 199. Nsc / 2A / 487 / 8 / 15 ( 492801472 ) 16 Bit Analog In- Put / Output Module -Fp110 200. Nsc / 2A / 487 / 8 / 16 ( 492801472 ) Analog Output Mod- Ule -Fpai-110 201. Nsc / 2A / 487 / 8 / 17 ( 492801472 ) Analog Output Mod- Ule -Fpai-110 202. Nsc / 2A / 487 / 8 / 18 ( 492801472 ) Analog Output Mod- Ule -Fpai-110 203. Nsc / 2A / 487 / 8 / 19 ( 492801472 ) Analog Output Mod- Ule -Fpai-110 204. Nsc / 2A / 487 / 8 / 20 ( 492801472 ) Analog Output Mod- Ule -Fpai-110 205. Nsc / 2A / 487 / 8 / 21 ( 492801472 ) 8Chanel 24Vdc Dis- Crete Input Module- Fpof300 206. Nsc / 2A / 487 / 8 / 22 ( 492801472 ) 8Chanel 24Vdc Dis- Crete Input Module- Fpof300 207. Nsc / 2A / 487 / 8 / 23 ( 492801472 ) 8Chanel 24Vdc Dis- Crete Input Module- Fpof300 208. Nsc / 2A / 487 / 8 / 24 ( 492801472 ) 8Chanel 24Vdc Dis- Crete Input Module- Fpof300 209. Nsc / 2A / 487 / 8 / 25 ( 492801472 ) 8Chanel 24Vdc Dis- Crete Input Module- Fpof300 210. Nsc / 2A / 487 / 8 / 26 ( 492801472 ) 16 Channel Discrete Output Module- Fpdo-401211. Nsc / 2A / 487 / 8 / 27 ( 492801472 ) 16 Channel Discrete Output Module- Fpdo-401 212. Nsc / 2A / 487 / 8 / 28 ( 492801472 ) 16 Channel Discrete Output Module- Fpdo-401 213. Nsc / 2A / 487 / 8 / 29 ( 492801472 ) 16 Channel Discrete Output Module- Fpdo-401 214. Nsc / 2A / 487 / 8 / 30 ( 492801472 ) 16 Channel Discrete Output Module- Fpdo-401 215. Nsc / 2A / 487 / 8 / 31 ( 492801472 ) 8 Channel Spst Re- Lay Output Module - Fp-Rly 420 216. Nsc / 2A / 487 / 8 / 32 ( 492801472 ) 8 Channel Spst Re- Lay Output Module - Fp-Rly 420 217. Nsc / 2A / 487 / 8 / 33 ( 492801472 ) 8 Channel Spst Re- Lay Output Module - Fp-Rly 420 218. Nsc / 2A / 487 / 8 / 34 ( 492801472 ) 8 Channel Counter Input Module - Fp- Ctr-500 219. Nsc / 2A / 487 / 8 / 35 ( 492801472 ) 8 Channel Counter Input Module - Fp- Ctr-500 220. Nsc / 2A / 487 / 8 / 36 ( 492801472 ) 8 Channel Pulse Generator With Ac- Cessories And Other Consumable 221. Nsc / 2A / 487 / 8 / 37 ( 492801472 ) Gpib-232Ct-A Hard- Ware Kit - 777520-01C 222. Nsc / 2A / 487 / 8 / 38 ( 492801472 ) Gpib-232Ct-A Hard- Ware Kit - 777520-01C 223. Nsc / 2A / 487 / 8 / 39 ( 492801472 ) Real Time Multipli- Cation - Pci7030 With Other Consumables 224. Nsc / 5A / 146 / 1 / 1 ( 492801472 ) Electronics, Electrical And Other Items 225. Nsc / 4A / 114 / 1 / 1 ( 492801472 ) Electronic Components For Twt Ampl. 226. Nsc / 4A / 128 / 4 / 1 ( 492801472 ) Electronic Components 227. Nsc / 4A / 133 / 4 / 1 ( 492801472 ) Microwave Generator With Acc 228. Nsc / 3A / 151 / 11 / 1 ( 492801472 ) Owen Power Supply 229. Nsc / 3A / 151 / 11 / 2 ( 492801472 ) Owen Power Supply 230. Nsc / 3A / 178 / 1 / 1 ( 492801472 ) Low Voltage Power Supply Module Model No.A23687001 231. Nsc / 3A / 178 / 1 / 2 ( 492801472 ) Hv Diode Model No.A.22818-002 232. Nsc / 3A / 192 / 9 / 1 ( 492801472 ) Transformers 233. Nsc / 3A / 192 / 9 / 2 ( 492801472 ) Transformers 234. Nsc / 3A / 192 / 9 / 3 ( 492801472 ) Transformers 235. Nsc / 3A / 192 / 9 / 4 ( 492801472 ) Transformers 236. Nsc / 3A / 192 / 9 / 5 ( 492801472 ) Transformers 237. Nsc / 3A / 192 / 9 / 6 ( 492801472 ) Transformers 238. Nsc / 3A / 192 / 9 / 7 ( 492801472 ) Transformers 239. Nsc / 3A / 192 / 9 / 8 ( 492801472 ) Transformers 240. Nsc / 3A / 192 / 9 / 9 ( 492801472 ) Transformers 241. Nsc / 3A / 192 / 9 / 10 ( 492801472 ) Transformers 242. Nsc / 3A / 196 / 2 / 1 ( 492801472 ) Wright Capacitor 243. Nsc / 3A / 196 / 4 / 1 ( 492801472 ) Oscilloscope Lecroy Make 244. Nsc / 2A / 204 / 14 / 1 ( 492801472 ) Pcb Job Work 245. Nsc / 3A / 211 / 5 / 1 ( 492801472 ) Lecroy Oscilloscope And Ac- Cessories Cd-Rw Upgrade 246. Nsc / 2A / 216 / 4 / 1 ( 492801472 ) Steerer / Quadropole Power Supplier 247. Nsc / 2A / 217 / 9 / 1 ( 492801472 ) Pcb 44.6 Savinon 248. Nsc / 2A / 217 / 9 / 2 ( 492801472 ) Pcb 44.6 Savinon 249. Nsc / 2A / 217 / 9 / 3 ( 492801472 ) Pcb 57.2 Savinon 250. Nsc / 2A / 217 / 9 / 4 ( 492801472 ) Pcb 57.2 Savinon 251. Nsc / 2A / 217 / 9 / 5 ( 492801472 ) Artworu Photography-60.51 252. Nsc / 2A / 217 / 9 / 6 ( 492801472 ) Do - 76.51 253. Nsc / 2A / 229 / 5 / 1 ( 492801472 ) Osciloscope La302 / Rm482 254. Nsc / 3A / 247 / 2 / 1 ( 492801472 ) D26 Diodes 255. Nsc / 2A / 276 / 5 / 1 ( 492801472 ) Control Panel ( 8108 2038 P-82038 ) 256. Nsc / 2A / 276 / 5 / 5 ( 492801472 ) Control Board ( P- 82412 ) 257. Nsc / 2A / 290 / 8 / 6 ( 492801472 ) Compact Pirani Gauge ( Tpr265, Dn16, 44036453 ) 258. Nsc / 2A / 290 / 8 / 7 ( 492801472 ) Compact Pirani Gauge ( Tpr265, Dn16, 44035575 ) 259. Nsc / 2A / 290 / 8 / 8 ( 492801472 ) Compact Cold Cathode Gauge ( Ikr251, Dn25, 44035575 ) 260. Nsc / 2A / 294 / 13 / 1 ( 492801472 ) High Voltage Power Supply Pcb 261. Nsc / 2A / 294 / 13 / 1 ( 492801472 ) Capacitors & Resistors 262. Nsc / 2A / 294 / 13 / 1 ( 492801472 ) Electronic Components 263. Nsc / 2A / 294 / 13 / 1 ( 492801472 ) High Voltage Power Supply ( Ele. Hard. ) 264. Nsc / 2A / 294 / 13 / 1 ( 492801472 ) Dspth Pcb 265. Nsc / 2A / 294 / 15 / 1 ( 492801472 ) Instrument Cable 266. Nsc / 4A / 367 / 4 / 1 ( 492801472 ) Teslameter 267. Nsc / 4A / 417 / 1 / 1 ( 492801472 ) Aqhesives 268. Nsc / 4A / 417 / 1 / 2 ( 492801472 ) Aqhesives 269. Nsc / 4A / 417 / 1 / 3 ( 492801472 ) Heat Thin Compound 270. Nsc / 4A / 417 / 1 / 4 ( 492801472 ) Heat Thin Compound 271. Nsc / 4A / 417 / 1 / 5 ( 492801472 ) Thin Primer 272. Nsc / 4A / 417 / 1 / 6 ( 492801472 ) Thin Primer 273. Nsc / 2A / 481 / 1 / 10 ( 492801472 ) Wafers For Leibf 274. Nsc / 2A / 482 / 1 ( 492801472 ) Spare Parts ( 4127 Ig ) 275. Nsc / 2A / 484 / 4 / 2 ( 492801472 ) High Voltage Diose Cap Assy276. Nsc / 2A / 484 / 4 / 3 ( 492801472 ) Electronic Components For Twt Ampl. 277. Nsc / 2A / 484 / 4 / 4 ( 492801472 ) Electronic Components For Twt 278. Nsc / 4A / 181 / 3 / 1 ( 492801815 ) Hp Colour Laser Jet Printer 279. Nsc / 3A / 185 / 4 / 1 ( 492801815 ) Scroll Pump 280. Nsc / 3A / 185 / 4 / 3 ( 492801815 ) Gauge Controller 281. Nsc / A / 4 / 1 / 1 ( 492801162 ) Delux Hyd. Drinea+Pouch Kit + Step Drill Set 282. Nsc / A / 251 / 14 / 1 ( 492801163 ) Alman Modular System 283. Nsc / A / 366 / 5 / 1 ( 492801164 ) Servo Voltage Stabilizer 284. Nsc / A / 422 / 2 / 1 ( 492801165 ) Pvc Insulated 4 Core X 6.0 Sq Mm Around Cable 285. Nsc / A / 431 / 6 / 1 ( 492801166 ) Single Phase Preventor Type But Csp-80 / Cc 40 286. Nsc / A / 431 / 6 / 2 ( 492801166 ) Single Phase Preventor Type But Csp-80 / Cc 40 287. Nsc / A / 431 / 6 / 3 ( 492801166 ) Single Phase Preventor Type Mpr -1 / 40 Monilac - 8800 288. Nsc / A / 431 / 6 / 4 ( 492801166 ) Single Phase Preventor Type Mpr -1 / 40 Monilac - 8800 289. Nsc / 2A / 117 / 8 / 1 ( 492801168 ) 3Ph Power & Energy Moni- Tor 290. Nsc / 2A / 117 / 8 / 2 ( 492801168 ) 3Ph Power & Energy Moni- Tor 291. Nsc / 2A / 120 / 1 / 1 ( 492801169 ) Compressor Auto Control System 292. Nsc / 2A / 120 / 1 / 2 ( 492801170 ) Compressor Auto Control System 293. Nsc / 2A / 120 / 1 / 3 ( 492801171 ) Modification Of Existing Control Panel Of He. Comprs 294. Nsc / 2A / 120 / 1 / 5 ( 492801172 ) Active Power Transducer Dc Isolated Transducer Dig- Ital Panel Meter 295. Nsc / 2A / 120 / 1 / 10 ( 492801173 ) Tlx Cd Pl 7Mp43 Soft- Ware For Plc Programming 296. Nsc / 2A / 120 / 1 / 11 ( 492801174 ) 3 Kva Ups System 297. Nsc / 2A / 120 / 1 / 12 ( 492801175 ) Sitc Of Remote Control Panel 298. Nsc / 2A / 214 / 2 / 8 40 A Contactor 299. Nsc / 2A / 334 / 18 / 1 ( 492801178 ) Motor Starter Panel For 6Hp, 3Hp Motor 300. Nsc / 2A / 334 / 18 / 2 ( 492801178 ) Motor Starter Panel For 6Hp, 3Hp Motor 301. Nsc / 2A / 354 / 4 / 1 ( 492801179 ) Exhaust Fan 302. Nsc / 2A / 391 / 2 / 1 ( 492801181 ) Transformer 303. Nsc / 2A / 391 / 2 / 2 ( 492801181 ) Transformer 304. Nsc / 2A / 342 / 1 / 1 ( 492801182 ) Supply & Fixing Of Cabling 305. Nsc / 2A / 342 / 2 / 1 ( 492801183 ) Sub-Station & Power Supply 306. Nsc / 2A / 346 / 11 / 2 ( 492801184 ) Self Starter Sm130p 307. Nsc / 2A / 354 / 7 / 1 ( 492801185 ) Voltage Sensitive Phase 308. Nsc / 2A / 354 / 7 / 2 ( 492801185 ) Voltage Sensitive Phase 309. Nsc / 4A / 35 / 1 / 22 ( 492801188 ) Spares For Vacu Tube 3C X 3000 / 17 310. Nsc / 4A / 49 / 6 / 1 ( 492801190 ) 50 Kva Step 3 Phasedown Transformer 311. Nsc / 3A / 264 / 4 / 1 ( 492801191 ) Self Starter For Kt 1150 312. Nsc / 3A / 264 / 4 / 2 ( 492801191 ) Self Starter For Kt 1150 313. Nsc / 3A / 269 / 12 / 1 ( 492801192 ) Amf Panel 314. Nsc / 3A / 270 / 2 / 1 ( 492801193 ) S / F Of Capacitor Duty 315. Nsc / 3A / 270 / 2 / 2 ( 492801193 ) S / F Of Capacitor Duty 316. Nsc / 3A / 270 / 2 / 3 ( 492801193 ) S / F Of Capacitor Duty 317. Nsc / 3A / 270 / 2 / 4 ( 492801193 ) S / F Of Capacitor Duty 318. Nsc / 3A / 270 / 2 / 5 ( 492801194 ) S / F Of Capacitor Duty 319. Nsc / 3A / 270 / 2 / 6 ( 492801194 ) S / F Of Capacitor Duty 320. Nsc / 3A / 270 / 2 / 7 ( 492801194 ) S / F Of Capacitor Duty 321. Nsc / 3A / 270 / 7 / 1 ( 492801195 ) Fan, Light Fitting Etc. 322. Nsc / 3A / 263 / 9 / 1 ( 492801196 ) S / F Of 800 Mccb 323. Nsc / 3A / 263 / 9 / 2 ( 492801196 ) Fixing Of Cmm 125 Sfu 324. Nsc / 3A / 263 / 9 / 3 ( 492801196 ) Fixing Of Cmm 125 Sfu 325. Nsc / 3A / 263 / 9 / 4 ( 492801196 ) Fixing Of Cmm 125 Sfu 326. Nsc / 3A / 263 / 9 / 5 ( 492801196 ) Shifting Of Db 327. Nsc / 3A / 101 / 7 / 3 ( 492801198 ) 19” Tube Display Box With Cutouts. 328. Nsc / 3A / 101 / 7 / 4 ( 492801198 ) 19” Tube Display Box With Cutouts. 329. Nsc / 3A / 101 / 11 / 1 ( 492801199 ) Colour Camera Sys- Tem With Acc. 330. Nsc / 3A / 101 / 5 / 1 ( 492801200 ) 14” Colour Monitor 331. Nsc / 3A / 101 / 6 / 1 ( 492801201 ) Day / Night Colour Camera 332. Nsc / 3A / 101 / 7 / 1 ( 492801202 ) 10Rpm Rotation Counter With Sen- Sor 333. Nsc / 3A / 101 / 7 / 2 ( 492801202 ) 10Rpm Rotation Counter With Sen- Sor 334. Nsc / 2A / 398 / 4 / 1 ( 492801203 ) Spt1107 Light Fittings 335. Nsc / 2A / 398 / 4 / 2 ( 492801203 ) Spt1107 Light Fittings 336. Nsc / 2A / 398 / 4 / 3 ( 492801204 ) Bollard Fitting 337. Nsc / 2A / 398 / 4 / 4 ( 492801204 ) Bollard Fitting 338. Nsc / 2A / 398 / 4 / 5 ( 492801204 ) Bollard Fitting 339. Nsc / 2A / 398 / 4 / 6 ( 492801205 ) Bollard Fitting 340. Nsc / 2A / 398 / 5 / 1 ( 492801206 ) Post Top Lantern Fitting 341. Nsc / 2A / 398 / 5 / 2 ( 492801206 ) Post Top Lantern Fitting 342. Nsc / 2A / 398 / 5 / 3 ( 492801207 ) Post Top Lantern Fitting 343. Nsc / 3A / 270 / 4 / 1 ( 492801222 ) Pc With Tft Monitor 344. Nsc / 3A / 274 / 2 / 1 ( 492801223 ) Lamps Etc 345. Nsc / 4A / 9 / 4 / 1 ( 492801224 ) Hts 50-08 346. Nsc / 3A / 264 / 1 / 2 ( 492801225 ) S / F Of Dm160 347. Nsc / 3A / 264 / 1 / 3 ( 492801225 ) S / F 110A Contractor 348. Nsc / 3A / 264 / 1 / 4 ( 492801225 ) S / F 110A Contractor 349. Nsc / 3A / 261 / 4 / 1 ( 492801227 ) 2X40 Watt Light Fit- Ting 350. Nsc / 3A / 261 / 4 / 2 ( 492801227 ) 2X40 Watt Light Fit- Ting 351. Nsc / 3A / 261 / 4 / 3 ( 492801227 ) 2X40 Watt Light Fit- Ting 352. Nsc / 3A / 261 / 4 / 4 ( 492801227 ) 2X40 Watt Light Fit- Ting 353. Nsc / 3A / 261 / 5 / 1 ( 492801228 ) Digimatic Caliper ( 200Mm ) 354. Nsc / 3A / 262 / 6 / 1 ( 492801229 ) Power Distribution With Vtpn Db 355. Nsc / 3A / 261 / 1 / 1 ( 492801230 ) Perforated G.I. Ca- Ble Tray 356. Nsc / 3A / 159 / 8 / 1 ( 492801231 ) 3Kva Onlline Ups Sys- Tem 357. Nsc / 3A / 202 / 5 / 1 ( 492801232 ) True On-Line Ups System 358. Nsc / 2A / 346 / 11 / 3 ( 492801234 ) Pump Water 359. Nsc / 3A / 150 / 11 / 1 ( 492801235 ) 5 Kva Online Ups Sys- Tem 360. Nsc / 3A / 386 / 9 / 14 ( 492801239 ) Washing Machine Model No.Wa90vpk 7 Kg Sam- Sung 361. Nsc / 3A / 203 / 14 / 1 ( 492801803 ) Computer Core 2 Due 362. Nsc / 3A / 203 / 14 / 2 ( 492801803 ) Computer Core 2 Due 363. Nsc / 3A / 205 / 11 / 1 ( 492801803 ) Intel Core 1 53: 0 Pc 364. Nsc / 3A / 321 / 8 / 1 ( 492801803 ) 17” Monitor Sumsung 365. Nsc / 3A / 321 / 8 / 2 ( 492801803 ) 17” Monitor Sumsung 366. Nsc / 3A / 385 / 13 / 1 ( 492801805 ) Core -2 Dua Intel Pentium Pc 367. Nsc / 3A / 387 / 13 / 1 ( 492801805 ) Printer Hp 1850 Deskjet 368. Nsc / 3A / 219 / 1 / 15 ( 492801493 ) Laser Diode With Power Supply 369. Nsc / 2A / 455 / 1 / 1 ( 492801495 ) Ohp - 400 370. Nsc / 3A / 378 / 7 / 1 ( 492801496 ) Collour Camera 371. Nsc / 3A / 379 / 1 ( 492801496 ) Mike & Stand 372. Nsc / 3A / 219 / 1 / 1 ( 492801503 ) Hellium Neon Laser 632.8 Wave Llength 373. Nsc / 3A / 219 / 1 / 2 ( 492801503 ) Xyz Translator 374. Nsc / 3A / 219 / 1 / 3 ( 492801503 ) X-Y Tilt Laser Mount 375. Nsc / 3A / 219 / 1 / 4 ( 492801503 ) X-Y Tilt Laser Mount 376. Nsc / 3A / 219 / 1 / 5 ( 492801503 ) X-Y Tilt Laser Mount 377. Nsc / 3A / 219 / 1 / 6 ( 492801503 ) X-Y Tilt Laser Mount 378. Nsc / 3A / 219 / 1 / 7 ( 492801503 ) X-Y Tilt Laser Mount 379. Nsc / 3A / 219 / 1 / 8 ( 492801503 ) X-Y Tilt Laser Mount 380. Nsc / 3A / 219 / 1 / 9 ( 492801503 ) X-Y Tilt Laser Mount 381. Nsc / 3A / 219 / 1 / 10 ( 492801503 ) X-Y Tilt Laser Mount 382. Nsc / 3A / 219 / 1 / 11 ( 492801503 ) X-Y Tilt Laser Mount 383. Nsc / 3A / 219 / 1 / 12 ( 492801503 ) Laser Diode With Power Supply 384. Nsc / 3A / 219 / 1 / 13 ( 492801503 ) Xyz Translator 385. Nsc / 3A / 219 / 1 / 14 ( 492801503 ) X-Y Tilt 386. Nsc / 3A / 220 / 1 / 1 ( 492801503 ) Intel Pentium 4 387. Nsc / 3A / 220 / 1 / 1 ( 492801503 ) Transcend 250 388. Nsc / 3A / 249 / 8 / 1 ( 492801503 ) Monitor 17” Tft 389. Nsc / 3A / 249 / 9 / 1 ( 492801503 ) Lcd Projector 390. Nsc / 4A / 256 / 1 / 1 ( 492801503 ) Spectrometer 391. Nsc / 3A / 260 / 1 / 1 ( 492801503 ) Hp Psc1410 Printer 392. Nsc / 4A / 440 / 10 / 1 ( 492801821 ) Computer -Intelcore I5 3.0 Oghz Fhd Tft 393. Nsc / 4A / 416 / 3 / 1 ( 492801821 ) Intel Core Computer 500 Gb 394. Nsc / 4A / 416 / 3 / 2 ( 492801821 ) Intel Core Computer 500 Gb 395. Nsc / 4A / 418 / 2 / 1 ( 492801821 ) Antistatic Temp. Controller Soldering Station Rx-701As 396. Nsc / 4A / 418 / 2 / 2 ( 492801821 ) Antistatic Temp. Controller Soldering Station Px-501As397. Nsc / 4A / 418 / 2 / 3 ( 492801821 ) Antistatic Temp. Controller Soldering Station Px-501As 398. Nsc / 4A / 419 / 2 / 1 ( 492801821 ) 15 Tons Manual Press 399. Nsc / 4A / 438 / 5 / 1 ( 492801821 ) Siborg Canada Model St- Sb Smart Tweezer 400. Nsc / 4A / 440 / 6 / 1 ( 492801821 ) 24 Led Dell Monitor 401. Nsc / A / 50 / 1 / 1 ( 492801563 ) Microvax Ii 159Mb Ba23system 402. Nsc / A / 50 / 1 / 2 ( 492801563 ) Microvax Iicpu W / 5Mb Fpu 403. Nsc / A / 50 / 1 / 3 ( 492801563 ) 159 Mb Disk Drive 404. Nsc / A / 50 / 1 / 4 ( 492801563 ) Disk Courdles 405. Nsc / A / 50 / 1 / 5 ( 492801563 ) 95 Mb Tape Drive 406. Nsc / A / 50 / 1 / 6 ( 492801563 ) 4 Line Multiplexer 407. Nsc / A / 50 / 1 / 7 ( 492801563 ) 8 Slot Expamion Chases 408. Nsc / A / 50 / 1 / 8 ( 492801563 ) Powecored 240 Vac 409. Nsc / A / 50 / 1 / 9 ( 492801563 ) English Language Di- Arys+Docs 410. Nsc / A / 50 / 1 / 10 ( 492801563 ) 4Mb Additional Memory 411. Nsc / A / 50 / 1 / 11 ( 492801563 ) 4Line Multiplier 412. Nsc / A / 50 / 1 / 12 ( 492801563 ) Cabinet Kit For Dzq11-M 413. Nsc / A / 50 / 1 / 13 ( 492801563 ) 159Mb Desktop Dises Drive 414. Nsc / A / 50 / 1 / 14 ( 492801563 ) Rd / Rx Controller For Rd 54 415. Nsc / A / 50 / 1 / 15 ( 492801563 ) 14 Mondchome Terminal 416. Nsc / A / 50 / 1 / 16 ( 492801563 ) Null Modem Cable 50Ft 417. Nsc / A / 50 / 1 / 17 ( 492801563 ) Magnetic Selisystem 418. Nsc / A / 50 / 1 / 18 ( 492801563 ) 300Lpm T Ext Board 419. Nsc / A / 50 / 1 / 19 ( 492801563 ) Uk Country Kit For Lg 31 420. Nsc / A / 50 / 1 / 20 ( 492801563 ) Ethernet Q-Bu Controller 421. Nsc / A / 50 / 1 / 21 ( 492801563 ) Cabinet Kit For Delqa422. Nsc / A / 50 / 1 / 22 ( 492801563 ) Ethernet Pvc Axial Cable 423. Nsc / A / 50 / 1 / 23 ( 492801563 ) Terminator For Bne 424. Nsc / A / 50 / 1 / 24 ( 492801563 ) Ethenet Trousereener 425. Nsc / A / 50 / 1 / 25 ( 492801563 ) Cable For H 4005 ( 40M ) 426. Nsc / A / 50 / 1 / 26 ( 492801563 ) Straight Counter Kit 427. Nsc / A / 50 / 1 / 27 ( 492801563 ) Insulation Toolkit 428. Nsc / A / 50 / 1 / 28 ( 492801563 ) Ethernet Jack 429. Nsc / A / 50 / 1 / 29 ( 492801563 ) Vms Operator System 430. Nsc / A / 50 / 1 / 30 ( 492801563 ) Vms Media + Decomentain 431. Nsc / A / 50 / 1 / 31 ( 492801563 ) Vax Decnet User Lincence 432. Nsc / A / 50 / 1 / 32 ( 492801563 ) Local Area Vax Culusier Link 433. Nsc / A / 50 / 1 / 33 ( 492801563 ) Vax Fortran Lincence 434. Nsc / A / 50 / 1 / 34 ( 492801563 ) Vax Fortran Media+Doc 435. Nsc / A / 50 / 1 / 35 ( 492801563 ) Vax Pascal Licence 436. Nsc / A / 50 / 1 / 36 ( 492801563 ) Vax Pascal Media +Doc Spare 437. Nsc / A / 50 / 1 / 37 ( 492801563 ) Ba 23 Power Supply 438. Nsc / A / 50 / 1 / 38 ( 492801563 ) Rd 32 Drive 439. Nsc / A / 50 / 1 / 39 ( 492801563 ) 4 Mb Memory 440. Nsc / A / 51 / 1 / 1 ( 492801563 ) 4 Line Multiplexer 441. Nsc / A / 51 / 1 / 2 ( 492801563 ) Vt 320 Spare Kit 442. Nsc / A / 51 / 1 / 3 ( 492801563 ) Trans Ducer 443. Nsc / A / 51 / 1 / 4 ( 492801563 ) Power Amp Pwa 444. Nsc / A / 51 / 1 / 5 ( 492801563 ) Tu 80 / 81 Uni. Power Sup- Ply 445. Nsc / A / 51 / 1 / 6 ( 492801563 ) Pwa Servo Control 446. Nsc / A / 51 / 1 / 7 ( 492801563 ) Rd / Rx Controller 447. Nsc / A / 51 / 1 / 8 ( 492801563 ) Ethernet Q-Buscont. 448. Nsc / A / 51 / 1 / 9 ( 492801563 ) Daisy Chain Cable 449. Nsc / A / 51 / 1 / 10 ( 492801563 ) Compact Tape 450. Nsc / A / 206 / 4 / 1 ( 492801564 ) Enter Twist Hub 8 451. Nsc / A / 206 / 4 / 2 ( 492801564 ) Hp 700 / Rx14.C.X. 452. Nsc / A / 206 / 4 / 3 ( 492801564 ) 700 Rx Server Tape On Dat 453. Nsc / A / 206 / 4 / 4 ( 492801564 ) Add Eisa Scsi Ii 454. Nsc / A / 206 / 4 / 5 ( 492801564 ) Disk Storage System 455. Nsc / A / 206 / 4 / 6 ( 492801564 ) Add 1.3 Gb Scsi Ii 456. Nsc / A / 206 / 4 / 7 ( 492801564 ) 0.9 Scsi Thani 457. Nsc / A / 206 / 4 / 8 ( 492801564 ) Screw Cable With Terminator 458. Nsc / A / 206 / 4 / 9 ( 492801564 ) Hp Thin Lan Trancier 459. Nsc / A / 206 / 4 / 10 ( 492801564 ) 32 Ram Add On 460. Nsc / A / 206 / 4 / 11 ( 492801564 ) Hp Laserjet Iv 461. Nsc / A / 206 / 4 / 12 ( 492801564 ) Add 4Mb Ram 462. Nsc / A / 206 / 4 / 13 ( 492801564 ) Hpu X 9.0 Dev. Tool 463. Nsc / A / 206 / 4 / 14 ( 492801564 ) Hpu X 9.0 S / W On Dat 464. Nsc / A / 206 / 4 / 15 ( 492801564 ) Hpu X 9.0 Doc Hardcopy 465. Nsc / A / 206 / 4 / 16 ( 492801564 ) Fortran 77 466. Nsc / A / 206 / 3 / 1 ( 492801640 ) Auto Card 467. Nsc / 2A / 241 / 1 / 1 ( 492801640 ) V X 2000 Rel-14.10 468. Nsc / 2A / 241 / 5 / 2 ( 492801640 ) Infs Tcp 469. Nsc / 2A / 241 / 5 / 3 ( 492801640 ) Exceed For Window 470. Nsc / 2A / 241 / 11 / 1 ( 492801640 ) Origin Software 471. Nsc / 2A / 242 / 2 / 1 ( 492801640 ) Dn Antivirus 3.0 Dos / Win 472. Nsc / 2A / 245 / 1 / 1 ( 492801640 ) Vx200 D Dos Renewal Lic 473. Nsc / 2A / 246 / 5 / 1 ( 492801640 ) Window Nt 4.0 Server 474. Nsc / 2A / 246 / 5 / 2 ( 492801640 ) Ms Office 97 Window Nt 4.0 475. Nsc / 2A / 246 / 5 / 3 ( 492801640 ) Ms Window 98 Full Pack 476. Nsc / 2A / 246 / 11 / 1 ( 492801640 ) Visual Studio 477. Nsc / 2A / 247 / 6 / 1 ( 492801640 ) Cad Star Software 478. Nsc / 2A / 247 / 11 / 1 ( 492801640 ) Vx200 Software For Win95 / 98 479. Nsc / 2A / 247 / 12 / 1 ( 492801640 ) Dragon Naturally Software 480. Nsc / 2A / 247 / 12 / 2 ( 492801640 ) Dragon Naturally Software 481. Nsc / 2A / 247 / 12 / 3 ( 492801640 ) Dragon Naturally Software 482. Nsc / 2A / 248 / 1 / 1 ( 492801640 ) Upgrade Of Irix 6.4 To 6.5 For Sgi Origin 200 & 02 483. Nsc / 2A / 248 / 1 / 2 ( 492801640 ) Upgrade Of Irix 6.4 To 6.5 For Sgi Origin 200 & 02 484. Nsc / 2A / 248 / 2 / 1 ( 492801640 ) Dragon Naturally Speaking Software 485. Nsc / 2A / 248 / 2 / 2 ( 492801640 ) Dragon Naturally Speaking Software 486. Nsc / 2A / 249 / 2 / 1 ( 492801640 ) Microsoft Windows Se ( Oem ) 487. Nsc / 2A / 249 / 2 / 2 ( 492801640 ) Microsoft Windows Se ( Oem ) 488. Nsc / 2A / 249 / 2 / 3 ( 492801640 ) Microsoft Windows Se ( Oem ) 489. Nsc / 2A / 249 / 2 / 4 ( 492801640 ) Microsoft Windows Se ( Oem ) 490. Nsc / 2A / 249 / 2 / 5 ( 492801640 ) Microsoft Windows Se ( Oem ) 491. Nsc / 2A / 249 / 2 / 6 ( 492801640 ) Microsoft Windows Se ( Oem ) 492. Nsc / 2A / 249 / 2 / 7 ( 492801640 ) Microsoft Windows Se ( Oem ) 493. Nsc / 2A / 249 / 2 / 8 ( 492801640 ) Microsoft Windows Se ( Oem ) 494. Nsc / 2A / 249 / 2 / 9 ( 492801640 ) Microsoft Windows Se ( Oem ) 495. Nsc / 2A / 249 / 2 / 10 ( 492801640 ) Microsoft Windows Se ( Oem ) 496. Nsc / 2A / 249 / 2 / 11 ( 492801640 ) Microsoft Windows Se ( Oem ) 497. Nsc / 2A / 249 / 2 / 12 ( 492801640 ) Microsoft Windows Se ( Oem ) 498. Nsc / 2A / 249 / 2 / 13 ( 492801640 ) Microsoft Windows Se ( Oem ) 499. Nsc / 2A / 249 / 2 / 14 ( 492801640 ) Microsoft Windows Se ( Oem ) 500. Nsc / 2A / 249 / 2 / 15 ( 492801640 ) Microsoft Windows Se ( Oem ) 501. Nsc / 2A / 249 / 2 / 16 ( 492801640 ) Microsoft Windows Se ( Oem ) 502. Nsc / 2A / 249 / 2 / 17 ( 492801640 ) Microsoft Windows Se ( Oem ) 503. Nsc / 2A / 249 / 2 / 18 ( 492801640 ) Microsoft Windows Se ( Oem ) 504. Nsc / 2A / 249 / 2 / 19 ( 492801640 ) Microsoft Windows Se ( Oem ) 505. Nsc / 2A / 249 / 2 / 20 ( 492801640 ) Microsoft Windows Se ( Oem ) 506. Nsc / 2A / 249 / 2 / 21 ( 492801640 ) Microsoft Windows Nt- Workstation 507. Nsc / 2A / 249 / 2 / 22 ( 492801640 ) Microsoft Windows Nt- Workstation 508. Nsc / 2A / 247 / 7 / 1 ( 492801640 ) Vx200 D Dos Software 509. Nsc / A / 201 / 2 / 1 ( 492801675 ) Bhurji Transformer For Above Computer 510. Nsc / 3A / 201 / 10 / 1 ( 492801675 ) 24- Port Switch D- Link Make 511. Nsc / 3A / 203 / 1 / 1 ( 492801675 ) Desktop Pc 512. Nsc / 3A / 204 / 4 / 1 ( 492801675 ) Thin Client Intel Atom 513. Nsc / 3A / 204 / 4 / 2 ( 492801675 ) Thin Client Intel Atom 514. Nsc / 3A / 204 / 4 / 3 Thin Client Intel Atom 521. Nsc / 3A / 204 / 6 / 5 ( 492801675 ) Thin Client For Lts 522. Nsc / 3A / 205 / 4 / 3 ( 492801675 ) Desktop Pc Intel Core 15 523. Nsc / 3A / 205 / 5 / 2 ( 492801675 ) Thin Client Intel Atom Cpu 1.6 Ghz 524. Nsc / 3A / 205 / 5 / 3 ( 492801675 ) Thin Client Intel Atom Cpu 1.6 Ghz 525. Nsc / A / 207 / 1 / 1 ( 492801675 ) 14 Vga Monitor 200 Watt Power Supply 3.5 Fdd 80386 With 2Mb Ram Cabinet Disk & Floppy Controller Dos 6.1 Upgrade Fdd 5.25 Hdd 120 Mb Key Board 101 Keys Serial Port Svga Controller 526. Nsc / 3A / 203 / 9 / 1 ( 492801767 ) Patch Panel 527. Nsc / 3A / 203 / 9 / 2 ( 492801767 ) Patch Panel 528. Nsc / 3A / 203 / 9 / 3 ( 492801767 ) Switch 529. Nsc / 3A / 203 / 9 / 4 ( 492801767 ) Switch 530. Nsc / 3A / 205 / 1 / 1 ( 492801767 ) Ridgeline 3.0 Network Man- Agement 531. Nsc / 3A / 205 / 1 / 1 ( 492801767 ) 10 Gbps Core Switching Sys- Tem 532. Nsc / 3A / 205 / 1 / 2 ( 492801767 ) Ridgeline 3.0 Network Man- Agement 533. Nsc / 3A / 205 / 1 / 2 ( 492801767 ) 10 Gbps Core Switching Sys- Tem 534. Nsc / 3A / 205 / 1 / 3 ( 492801767 ) Ridgeline 3.0 Network Man- Agement 535. Nsc / 3A / 205 / 1 / 3 ( 492801767 ) 10 Gbps Core Switching Sys- Tem 536. Nsc / 3A / 205 / 1 / 4 ( 492801767 ) Ridgeline 3.0 Network Man- Agement 537. Nsc / 3A / 205 / 1 / 4 ( 492801767 ) 10 Gbps Core Switching Sys- Tem 538. Nsc / 3A / 205 / 1 / 5 ( 492801767 ) Ridgeline 3.0 Network Man- Agement 539. Nsc / 3A / 205 / 1 / 5 ( 492801767 ) 10 Gbps Core Switching Sys- Tem 540. Nsc / 3A / 205 / 1 / 6 ( 492801767 ) Ridgeline 3.0 Network Man- Agement 541. Nsc / 3A / 205 / 1 / 6 ( 492801767 ) 10 Gbps Core Switching Sys- Tem 542. Nsc / 3A / 205 / 1 / 7 ( 492801767 ) Ridgeline 3.0 Network Man- Agement 1 543. Nsc / 3A / 205 / 1 / 7 ( 492801767 ) 10 Gbps Core Switching Sys- Tem 1 544. Nsc / 3A / 205 / 1 / 10 ( 492801767 ) Ridgeline 3.0 Network Man- Agement 1 545. Nsc / 3A / 205 / 1 / 10 ( 492801767 ) 10 Gbps Core Switching Sys- Tem 1 546. Nsc / 3A / 205 / 1 / 12 ( 492801767 ) Ridgeline 3.0 Network Man- Agement 1 547. Nsc / 3A / 205 / 1 / 12 ( 492801767 ) 10 Gbps Core Switching Sys- Tem 1 548. Nsc / 3A / 205 / 1 / 15 ( 492801767 ) Ridgeline 3.0 Network Man- Agement 1 549. Nsc / 3A / 205 / 1 / 15 ( 492801767 ) 10 Gbps Core Switching Sys- Tem 1 550. Nsc / 2A / 245 / 6 / 1 ( 492801767 ) 10Mbps Non-Managed Hub With 8Utp, 1Bnc Port 1 551. Nsc / 2A / 245 / 6 / 2 ( 492801767 ) 10Mbps Non-Managed Hub With 8Utp, 1Bnc Port 1 552. Nsc / 2A / 245 / 7 / 1 ( 492801767 ) Anti Radiation Monitor 1 553. Nsc / 2A / 245 / 9 / 1 ( 492801767 ) Cd Writer 1 554. Nsc / 2A / 246 / 4 / 1 ( 492801767 ) External Modem 1 555. Nsc / 2A / 248 / 4 / 1 ( 492801767 ) Voice / Data / Fax Modem Ex- Ternal 33.6 Kbps 1 556. Nsc / 2A / 248 / 7 / 1 ( 492801767 ) Modem Gvc 56K External 1 557. Nsc / 2A / 248 / 7 / 2 ( 492801767 ) Modem Gvc 56K External 1 558. Nsc / 2A / 248 / 7 / 3 ( 492801767 ) Modem Gvc 56K External 1 559. Nsc / 2A / 248 / 7 / 4 ( 492801767 ) Modem Gvc 56K External 1 560. Nsc / 2A / 249 / 1 / 1 ( 492801767 ) Optical Trans Receiver 1 561. Nsc / 3A / 321 / 7 / 1 ( 492801767 ) 512 Kbps Modem / Rounter 1 562. Nsc / 3A / 203 / 9 / 5 ( 492801785 ) Rack Mount Pc, Intel Plat- Form 1 563. Nsc / 3A / 203 / 9 / 6 ( 492801785 ) Rack Mount Pc, Intel Plat- Form 1 564. Nsc / 3A / 203 / 9 / 7 ( 492801785 ) Rack Mount Pc, Intel Plat- Form 1 565. Nsc / 3A / 203 / 9 / 8 ( 492801785 ) Rack Mount Pc, Intel Plat- Form 1 566. Nsc / 3A / 203 / 9 / 9 ( 492801785 ) Rack Mount Pc, Intel Plat- Form 567. Nsc / 3A / 203 / 9 / 10 ( 492801785 ) Rack Mount Pc, Intel Plat- Form 568. Nsc / 3A / 203 / 9 / 11 ( 492801785 ) Rack Mount Pc, Intel Plat- Form 569. Nsc / 3A / 203 / 9 / 12 ( 492801785 ) Rack Mount Pc, Intel Plat- Form 570. Nsc / 3A / 203 / 9 / 13 ( 492801785 ) Rack Mount Pc, Intel Plat- Form 571. Nsc / 3A / 203 / 9 / 14 ( 492801785 ) Rack Mount Pc, Intel Plat- Form 572. Nsc / 3A / 203 / 9 / 15 ( 492801785 ) Rack Mount Pc, Intel Plat- Form 573. Nsc / 3A / 203 / 9 / 16 ( 492801785 ) Rack Mount Pc, Intel Plat- Form 574. Nsc / 3A / 203 / 9 / 17 ( 492801785 ) Rack Mount Pc, Intel Plat- Form 575. Nsc / 3A / 203 / 9 / 18 ( 492801785 ) Rack Mount Pc, Intel Plat- Form 576. Nsc / 3A / 203 / 9 / 19 ( 492801785 ) Rack Mount Pc, Intel Plat- Form 577. Nsc / 3A / 203 / 9 / 20 ( 492801785 ) Rack Mount Pc, Intel Plat- Form 578. Nsc / 3A / 204 / 12 / 1 ( 492801785 ) Intel Xeon Rack 579. Nsc / 3A / 204 / 12 / 2 ( 492801785 ) Intel Xeon Rack 580. Nsc / 3A / 204 / 12 / 3 ( 492801785 ) Intel Xeon Rack 581. Nsc / 3A / 204 / 12 / 4 ( 492801785 ) Intel Xeon Rack 582. Nsc / 3A / 205 / 2 / 1 ( 492801785 ) 1U Rack Mountable Rem X5620 583. Nsc / 3A / 205 / 2 / 2 ( 492801785 ) 1U Rack Mountable Rem X5620 584. Nsc / 3A / 205 / 3 / 1 ( 492801785 ) Iu Rack Mount Server Intel 585. Nsc / 3A / 205 / 3 / 2 ( 492801785 ) Iu Rack Mount Server Intel 586. Nsc / 5A / 223 / 1 / 1 ( 492801785 ) Server Iu Dual Xeon 5620 587. Nsc / 5A / 223 / 1 / 2 ( 492801785 ) Server Iu Dual Xeon 5620 588. Nsc / 5A / 223 / 1 / 3 ( 492801785 ) Server Iu Dual Xeon 5620 589. Nsc / A / 201 / 4 / 4 ( 492801806 ) Ms Fortran 590. Nsc / A / 201 / 6 / 5 ( 492801806 ) Monitor + Ms Windows 591. Nsc / 3A / 201 / 8 / 1 ( 492801806 ) Scanner - ( Hp 4500C ) 592. Nsc / 3A / 201 / 8 / 2 ( 492801806 ) Scanner - ( Hp 4500C ) 593. Nsc / 3A / 201 / 13 / 1 ( 492801806 ) Hp Llaserjet 2300 Printer 594. Nsc / 3A / 201 / 13 / 2 ( 492801806 ) Hp Llaserjet 2300 Printer 595. Nsc / 3A / 201 / 13 / 3 ( 492801806 ) Hp Llaserjet 2300 Printer 596. Nsc / 3A / 201 / 13 / 4 ( 492801806 ) Hp Llaserjet 2300 Printer 597. Nsc / 3A / 201 / 13 / 5 ( 492801806 ) Hp Llaserjet 2300 Printer 598. Nsc / 3A / 201 / 13 / 6 ( 492801806 ) Hp Llaserjet 2300 Printer 599. Nsc / A / 202 / 8 / 1 ( 492801806 ) Ingress Software 600. Nsc / 3A / 202 / 8 / 1 ( 492801806 ) Intel P-4 Based Pc 601. Nsc / 3A / 203 / 1 / 1 ( 492801806 ) Desktop Pc 602. Nsc / 3A / 203 / 1 / 2 ( 492801806 ) Desktop Pc 603. Nsc / 3A / 203 / 2 / 1 ( 492801806 ) Hp Printer Hp 1410 604. Nsc / 3A / 203 / 3 / 1 ( 492801806 ) Intel Pentium-4 Based Pc With Tft 605. Nsc / 3A / 203 / 3 / 2 ( 492801806 ) Intel Pentium-4 Based Pc With Tft 606. Nsc / A / 203 / 6 / 6 ( 492801806 ) Vt 220 Compatible Terminal 607. Nsc / A / 203 / 6 / 8 ( 492801806 ) Vt 220 Compatible Terminal 608. Nsc / A / 203 / 6 / 9 ( 492801806 ) Vt 220 Compatible Terminal 609. Nsc / A / 203 / 6 / 10 ( 492801806 ) Vt 220 Compatible Terminal 610. Nsc / 3A / 203 / 10 / 1 ( 492801806 ) Notebook Pc 611. Nsc / 3A / 204 / 1 / 1 ( 492801806 ) Desktop Pc 612. Nsc / 3A / 204 / 1 / 2 ( 492801806 ) Desktop Pc 614. Nsc / 3A / 204 / 1 / 4 ( 492801806 ) Desktop Pc 615. Nsc / 3A / 204 / 2 / 1 ( 492801806 ) Hp Elite Book Note Book Pc 616. Nsc / 3A / 204 / 2 / 3 ( 492801806 ) Hp Elite Book Note Book Pc 617. Nsc / 3A / 204 / 11 / 1 ( 492801806 ) Compaq Laptop 618. Nsc / 3A / 204 / 11 / 1 ( 492801806 ) Thin Client 619. Nsc / 3A / 204 / 11 / 2 ( 492801806 ) Thin Client 620. Nsc / 3A / 204 / 11 / 3 ( 492801806 ) Thin Client 621. Nsc / 3A / 204 / 11 / 4 ( 492801806 ) Thin Client 622. Nsc / 3A / 204 / 11 / 5 ( 492801806 ) Thin Client 623. Nsc / 3A / 205 / 4 / 2 ( 492801806 ) Desktop Pc Intel Core 15 624. Nsc / 3A / 205 / 5 / 2 ( 492801806 ) Thin Client Intel Atom Cpu 1.6 Ghz 625. Nsc / 3A / 205 / 5 / 3 ( 492801806 ) Thin Client Intel Atom Cpu 1.6 Ghz 626. Nsc / 3A / 205 / 5 / 4 ( 492801806 ) Thin Client Intel Atom Cpu 1.6 Ghz 627. Nsc / 3A / 205 / 5 / 5 ( 492801806 ) Thin Client Intel Atom Cpu 1.6 Ghz 628. Nsc / 3A / 205 / 6 / 1 ( 492801806 ) Notebook Pc Toshiba Portegge 629. Nsc / 3A / 206 / 7 / 2 ( 492801806 ) Hp Laserjet Printer 630. Nsc / 3A / 206 / 7 / 4 ( 492801806 ) Hp Laserjet Printer 631. Nsc / A / 209 / 3 / 5 ( 492801806 ) 250 Mb Cartridge Tape Drive 632. Nsc / A / 209 / 3 / 13 ( 492801806 ) Pcl At 486 Dx-2 With 4Mb Ram 633. Nsc / 2A / 241 / 5 / 1 ( 492801806 ) Link Pc Unix 634. Nsc / 2A / 241 / 6 / 26 ( 492801806 ) D-Link Tcp / Ip 635. Nsc / 2A / 242 / 6 / 1 ( 492801806 ) Manual For Internet Fire- Walls 636. Nsc / 2A / 243 / 1 / 1 ( 492801806 ) Computer-Silicon Graphics 637. Nsc / 2A / 243 / 1 / 2 ( 492801806 ) Computer-Silicon Graphics 638. Nsc / 2A / 243 / 4 / 1 ( 492801806 ) Intel-Pentium, 166Mmxd16mb 639. Nsc / 2A / 243 / 6 / 1 ( 492801806 ) Hp Sj 4C 640. Nsc / 2A / 244 / 1 / 1 ( 492801806 ) Intel Pentium Ii Smp Com- Puter System With 128Nd 641. Nsc / 2A / 244 / 1 / 1 ( 492801806 ) Busy Bee 386 Com- Puter Intel 642. Nsc / 2A / 244 / 1 / 2 ( 492801806 ) Intel Pentium Ii Smp Com- Puter System With 128Nd 643. Nsc / 2A / 245 / 5 / 1 ( 492801806 ) 24X Internal Cd Rom Drive 644. Nsc / 2A / 245 / 5 / 2 ( 492801806 ) 24X Internal Cd Rom Drive 645. Nsc / 2A / 245 / 5 / 3 ( 492801806 ) 24X Internal Cd Rom Drive 646. Nsc / 2A / 245 / 5 / 4 ( 492801806 ) 24X Internal Cd Rom Drive 647. Nsc / 2A / 245 / 5 / 5 ( 492801806 ) 24X Internal Cd Rom Drive 648. Nsc / 2A / 245 / 5 / 6 ( 492801806 ) 24X Internal Cd Rom Drive 649. Nsc / 2A / 245 / 9 / 1 ( 492801806 ) Cd Writer 650. Nsc / 2A / 246 / 2 / 1 ( 492801806 ) Deltacad Ver 3.1 For Win- Dow 651. Nsc / 2A / 246 / 3 / 1 ( 492801806 ) Hp Cd Writer 652. Nsc / 2A / 247 / 1 / 1 ( 492801806 ) Cyrix Mii Pc 266 Mhz 653. Nsc / 2A / 247 / 3 / 1 ( 492801806 ) Push Button Phone 654. Nsc / 2A / 247 / 9 / 1 ( 492801806 ) Winca Super On Window 655. Nsc / 2A / 247 / 10 / 1 ( 492801806 ) Power Term Software From 656. Nsc / 2A / 247 / 13 / 1 ( 492801806 ) Hp Cd Writer 657. Nsc / 2A / 247 / 14 / 1 ( 492801806 ) 15 Color Monitor Samtron 658. Nsc / 2A / 247 / 14 / 2 ( 492801806 ) 15 Color Monitor Samtron 659. Nsc / 2A / 247 / 14 / 3 ( 492801806 ) 15 Color Monitor Samtron 660. Nsc / 2A / 247 / 14 / 4 ( 492801806 ) 15 Color Monitor Samtron 661. Nsc / 2A / 248 / 3 / 1 ( 492801806 ) Hp- Cd Writer 662. Nsc / 2A / 248 / 8 / 1 ( 492801806 ) Pc Piii 550 Mhz 663. Nsc / 2A / 248 / 8 / 2 ( 492801806 ) Pc Piii 550 Mhz 664. Nsc / 2A / 248 / 8 / 3 ( 492801806 ) Printer Hp 640C 665. Nsc / 2A / 248 / 8 / 4 ( 492801806 ) Printer Hp 640C 666. Nsc / 3A / 381 / 4 / 1 ( 492801806 ) Multimedia Projector 667. Nsc / 4A / 122 / 7 / 1 ( 492801806 ) Desktop Pc 668. Nsc / 4A / 301 / 6 / 1 ( 492801806 ) Pc 15 650 3.2 Gz Computer 669. Nsc / 5A / 351 / 1 / 1 ( 492801806 ) Thin Client Intel Atoms 670. Nsc / 5A / 351 / 1 / 2 ( 492801806 ) Thin Client Intel Atoms 671. Nsc / 5A / 351 / 1 / 3 ( 492801806 ) Thin Client Intel Atoms 672. Nsc / 5A / 351 / 1 / 4 ( 492801806 ) Thin Client Intel Atoms 673. Nsc / 5A / 351 / 1 / 5 ( 492801806 ) Thin Client Intel Atoms 674. Ap / 391 / 2 / 1 ( 492801806 ) Intel Pentium 675. Ap / 391 / 2 / 2 ( 492801806 ) Intel Pentium 676. Nsc / A / 201 / 6 / 4 ( 492801819 ) Mouse 677. Nsc / 2A / 246 / 4 / 1 ( 492801819 ) Applixware Office For Linux Deluxe 678. Nsc / 3A / 382 / 17 / 1 ( 492801819 ) Note Book Pc 679. Nsc / 2A / 241 / 6 / 1 ( 492801820 ) D-Link , De-220 Pct 680. Nsc / 2A / 241 / 6 / 2 ( 492801820 ) D-Link , De-220 Pct 681. Nsc / 2A / 241 / 6 / 3 ( 492801820 ) D-Link , De-220 Pct 682. Nsc / 2A / 241 / 6 / 4 ( 492801820 ) D-Link , De-220 Pct 683. Nsc / 2A / 241 / 6 / 5 ( 492801820 ) D-Link , De-220 Pct 684. Nsc / 2A / 241 / 6 / 6 ( 492801820 ) D-Link , De-220 Pct 685. Nsc / 2A / 241 / 6 / 7 ( 492801820 ) D-Link , De-220 Pct 686. Nsc / 2A / 241 / 6 / 8 ( 492801820 ) D-Link , De-220 Pct 687. Nsc / 2A / 241 / 6 / 9 D-Link , De-220 Pct688. Nsc / 2A / 241 / 6 / 10 ( 492801820 ) D-Link , De-220 Pct 689. Nsc / 2A / 241 / 6 / 11 ( 492801820 ) D-Link , De-220 Pct 690. Nsc / 2A / 241 / 6 / 12 ( 492801820 ) D-Link , De-220 Pct 691. Nsc / 2A / 241 / 6 / 13 ( 492801820 ) D-Link , De-220 Pct 692. Nsc / 2A / 241 / 6 / 14 ( 492801820 ) D-Link , De-220 Pct 693. Nsc / 2A / 241 / 6 / 15 ( 492801820 ) D-Link , De-220 Pct 694. Nsc / 2A / 241 / 6 / 16 ( 492801820 ) D-Link , De-220 Pct 695. Nsc / 2A / 241 / 6 / 17 ( 492801820 ) D-Link , De-220 Pct 696. Nsc / 2A / 241 / 6 / 18 ( 492801820 ) D-Link , De-220 Pct 697. Nsc / 2A / 241 / 6 / 19 ( 492801820 ) D-Link , De-220 Pct 698. Nsc / 2A / 241 / 6 / 20 ( 492801820 ) D-Link , De-220 Pct 699. Nsc / 2A / 241 / 6 / 21 ( 492801820 ) D-Link , De-220 Pct 700. Nsc / 2A / 241 / 6 / 22 ( 492801820 ) D-Link , De-220 Pct 701. Nsc / 2A / 241 / 6 / 23 ( 492801820 ) D-Link , De-220 Pct 702. Nsc / 2A / 241 / 6 / 24 ( 492801820 ) D-Link , De-220 Pct 703. Nsc / 2A / 241 / 6 / 25 ( 492801820 ) D-Link , De-220 Pct 704. Nsc / A / 243 / 11 / 1 ( 492801801 ) Plastic Chair 705. Nsc / 3A / 377 / 3 / 1 ( 492801801 ) Fax Machine - Canon ( B-155 ) 706. Nsc / 4A / 166 / 6 / 1 ( 492801143 ) Computer Intel Core2 Duo 707. Nsc / 4A / 359 / 5 / 1 ( 492801143 ) Computer Intel Core2 Duo 708. Nsc / 3A / 210 / 4 / 2 ( 492801237 ) Camera Power Supply, Mon- Itor , Gsco Catalyst 29Sog Ati 24 Port 10 / 100 Switch Rack With Accessories , 7 Nsc / 3A / 153 / 13 / 2 ( 492801827 ) Telephone Instruments 8 Nsc / 3A / 159 / 9 / 1 ( 492801827 ) Bpl Instruments 9 Nsc / 3A / 159 / 9 / 2 ( 492801827 ) Bpl Instruments 10 Nsc / 3A / 159 / 9 / 3 ( 492801827 ) Bpl Instruments 11 Nsc / 3A / 164 / 1 / 1 ( 492801827 ) Telephone Instru- Ment ( Bpl ) 12 Nsc / 3A / 164 / 1 / 2 ( 492801827 ) Telephone Instru- Ment ( Bpl ) 13 Nsc / 3A / 173 / 6 / 1 ( 492801827 ) Bpl 3600 M 14 Nsc / 3A / 173 / 6 / 2 ( 492801827 ) Bpl 3600 M 15 Nsc / 3A / 173 / 6 / 3 ( 492801827 ) Bpl 3600 M 16 Nsc / 3A / 173 / 7 / 1 ( 492801827 ) Telephone Instrument 17 Nsc / 3A / 173 / 7 / 2 ( 492801827 ) Telephone Instrument 46 Nsc / 2A / 416 / 15 / 2 ( 492801827 ) Telephone Instru- Ments 47 Nsc / 3A / 201 / 1 / 1 ( 492801828 ) D-Link Keyboard Video Mouse Switch 48 Nsc / 3A / 202 / 16 / 1 ( 492801828 ) Gsco Catalyst 29Sog 49 Nsc / 3A / 202 / 16 / 2 ( 492801828 ) Gsco Catalyst 29Sog 50 Nsc / 3A / 202 / 16 / 3 ( 492801828 ) Gsco Catalyst 29Sog 51 Nsc / 3A / 202 / 16 / 4 ( 492801828 ) Gsco Catalyst 29Sog 52 Nsc / 3A / 204 / 3 / 1 ( 492801828 ) Cpu Intel Core 2Duo E8400 53 Nsc / 2A / 249 / 7 / 1 ( 492801828 ) Ati 24 Port 10 / 100 Switch 54 Nsc / 2A / 249 / 7 / 2 ( 492801828 ) Ati 24 Port 10 / 100 Switch 55 Nsc / 2A / 249 / 7 / 5 ( 492801828 ) Rack With Accessories 56 Nsc / 2A / 249 / 8 / 1 ( 492801828 ) 24 Port 10 / 100 Switch ( At-Fs7241-50 ) 57 Nsc / 2A / 249 / 9 / 1 ( 492801828 ) Ati 24 Port 10 / 100 Switch 58 Nsc / 2A / 249 / 9 / 2 ( 492801828 ) Ati 24 Port 10 / 100 Switch 59 Nsc / 4A / 130 / 5 / 1 ( 492801828 ) Panasonic Cordless Phone 60 Nsc / A / 365 / 6 / 1 ( 492801828 ) Cost Of Intercom Function Box Parallel Connector Cir- Cuit 61 Nsc / A / 227 / 11 / 1 ( 492801828 ) Godrej Filing 62 Nsc / 2A / 242 / 5 / 3 ( 492801829 ) Jack Panel V 86 Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. Nsc / 3A / 189 / 3 Pcb Daughter 87 ( 492801518 ) Board ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. Nsc / 3A / 189 / 3 Screen Printing Of Front ( 492801518 ) Panel ( As Per Let- 88 Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. Nsc / 3A / 189 / 3 Teflon Swiitch ( As Per 89 ( 492801518 ) Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 90 Nsc / 3A / 189 / 3 ( 492801518 ) Ic Sockets ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 91 Nsc / 3A / 189 / 3 ( 492801518 ) Camac Crate Con- Troller ( Xl 17256E - Pd 8C, Xc 4013E - 4Pq 240C ) ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 92 Nsc / 3A / 189 / 3 ( 492801518 ) Gonio Control Module ( Xl 17128E - Pd 8C, Xc 4003E - Pq 100C ) ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 93 Nsc / 3A / 189 / 3 ( 492801518 ) Tsev83102 Sg- Bgl ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 94 Nsc / 3A / 189 / 3 ( 492801518 ) Electronic Compo- Nents ( As Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 95 Nsc / 3A / 189 / 3 ( 492801518 ) Tsev 81102 G0fs ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 96 Nsc / 3A / 189 / 3 ( 492801518 ) Pds+Adc * ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 97 Nsc / 3A / 189 / 3 ( 492801518 ) Pds+Adc * ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 98 Nsc / 3A / 189 / 3 ( 492801518 ) Camac Frames ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 99 Nsc / 3A / 189 / 3 ( 492801518 ) Ic-Xc17256 Dpc ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 100 Nsc / 3A / 189 / 3 ( 492801518 ) 100 E , 33.2K, 100Nfm 100 Ppf, ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 101 Nsc / 3A / 189 / 3 ( 492801518 ) A1937 Abr ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 No. Of Modules Is 35. 102 Nsc / 3A / 189 / 3 ( 492801518 ) Components ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 103 Nsc / 3A / 189 / 3 ( 492801518 ) Dspth Pcb ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 104 Nsc / 3A / 189 / 3 ( 492801518 ) 19” Metal Box ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 105 Nsc / 3A / 189 / 3 ( 492801518 ) Pcm33355f ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 106 Nsc / 3A / 189 / 3 ( 492801518 ) Ds Pth Pcb ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 107 Nsc / 3A / 189 / 3 ( 492801518 ) Ds Pth Pcb ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 108 Nsc / 3A / 189 / 3 ( 492801518 ) Ds Pth Pcb ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 109 Nsc / 3A / 189 / 3 ( 492801518 ) Ds Pth Pcb ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 110 Nsc / 3A / 189 / 3 ( 492801518 ) Ds Pth Pcb ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 111 Nsc / 3A / 189 / 3 ( 492801518 ) Ds Pth Pcb ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 112 Nsc / 3A / 189 / 3 ( 492801518 ) Dspth Camac Pcb ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 113 Nsc / 3A / 189 / 3 ( 492801518 ) Dspth Camac Pcb ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 114 Nsc / 3A / 189 / 3 ( 492801518 ) Dspth Camac Pcb ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 115 Nsc / 3A / 189 / 3 ( 492801518 ) Dspth Camac Pcb ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 116 Nsc / 3A / 189 / 3 ( 492801518 ) Dspth Camac Pcb ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 117 Nsc / 3A / 189 / 3 ( 492801518 ) Dspth Camac Pcb ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 118 Nsc / 3A / 189 / 3 ( 492801518 ) Pcm33355f ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 119 Nsc / 3A / 189 / 3 ( 492801518 ) Pcm33355f ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 120 Nsc / 3A / 189 / 3 ( 492801518 ) Pcm33355f ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into 121 Nsc / 3A / 189 / 3 ( 492801518 ) Pcm33355f ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 122 Nsc / 3A / 189 / 3 ( 492801518 ) Pcm33355f ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 123 Nsc / 3A / 189 / 3 ( 492801518 ) Ddar 512 M ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 124 Nsc / 3A / 189 / 3 ( 492801518 ) Ddar 512 M ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 125 Nsc / 3A / 189 / 3 ( 492801518 ) Ddar 512 M ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 126 Nsc / 3A / 189 / 3 ( 492801518 ) Ddar 512 M ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 127 Nsc / 3A / 189 / 3 ( 492801518 ) So-Ddr400 200 Pin ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 128 Nsc / 3A / 189 / 3 ( 492801518 ) Ddar 512 M ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 129 Nsc / 3A / 189 / 3 ( 492801518 ) 512Cf Disk Door 19 ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total Of Modules Is 35. 130 Nsc / 3A / 189 / 3 ( 492801518 ) Pcm-3370F, Pc-133Sd 512 Mb ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 131 Nsc / 3A / 189 / 3 ( 492801518 ) Inductor Ferrite ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 132 Nsc / 3A / 189 / 3 ( 492801518 ) Cclp Pcb ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 133 Nsc / 3A / 189 / 3 ( 492801518 ) 4610X101-681 ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 134 Nsc / 3A / 189 / 3 ( 492801518 ) 2W Socket ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 135 Nsc / 3A / 189 / 3 ( 492801518 ) Solder Wire ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 136 Nsc / 3A / 189 / 3 ( 492801518 ) Printing Of Print Pad ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 137 Nsc / 3A / 189 / 3 ( 492801518 ) Res Array 680, As7c256- 155C ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 138 Nsc / 3A / 189 / 3 ( 492801518 ) Inductor Pcb Header ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 139 Nsc / 3A / 189 / 3 ( 492801518 ) Pc Soldering Wick ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 140 Nsc / 3A / 189 / 3 ( 492801518 ) Front Panel Big ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 141 Nsc / 3A / 189 / 3 ( 492801518 ) 4 Layer Pcb Adc ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 142 Nsc / 3A / 189 / 3 ( 492801518 ) Pcb Adc ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 143 Nsc / 3A / 189 / 3 ( 492801518 ) Pcb Adc ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 144 Nsc / 3A / 189 / 3 ( 492801518 ) Front Panel Printer ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 145 Nsc / 3A / 189 / 3 ( 492801518 ) Front Panel Printer ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 146 Nsc / 3A / 189 / 3 ( 492801518 ) Dspth Pcb ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 147 Nsc / 3A / 189 / 3 ( 492801518 ) Pcm 3550 F, Dim, Cf 32 Mb ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 148 Nsc / 3A / 189 / 3 ( 492801518 ) Lm 1084It-50 ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 149 Nsc / 3A / 189 / 3 ( 492801518 ) Electronic Compo- Nents ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 150 Nsc / 3A / 189 / 3 ( 492801518 ) Electronic Compo- Nents ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 151 Nsc / 3A / 189 / 3 ( 492801518 ) Diode Ga ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 152 Nsc / 3A / 189 / 3 ( 492801518 ) Ds Pth Pcb 1.6 / 70U ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 153 Nsc / 3A / 189 / 3 ( 492801518 ) Four Layer Pcb ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 154 Nsc / 3A / 189 / 3 ( 492801518 ) Layer Bit Part :Pcb ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 155 Nsc / 3A / 189 / 3 ( 492801518 ) Electronic Compo- Nents ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 156 Nsc / 3A / 189 / 3 ( 492801518 ) Passive Active Electronic Comp. ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 157 Nsc / 3A / 189 / 3 ( 492801518 ) Electronic Compo- Nents ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 158 Nsc / 3A / 189 / 3 ( 492801518 ) Electronic Compo- Nents ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 159 Nsc / 3A / 189 / 3 ( 492801518 ) Ek-56-Sp605 ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 160 Nsc / 3A / 189 / 3 ( 492801518 ) Passive Active Electronic Comp. ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 161 Nsc / 3A / 189 / 3 ( 492801518 ) Lmk03000 Ceval ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 162 Nsc / 3A / 189 / 3 ( 492801518 ) 4 Layer Pcboard ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 163 Nsc / 3A / 189 / 3 ( 492801518 ) 87705-9001 ( Electronic Components ) ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 164 Nsc / 3A / 189 / 3 ( 492801518 ) Pcb ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 165 Nsc / 3A / 189 / 3 ( 492801518 ) Spatern 3E Chip ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Of Modules Is 35. 166 Nsc / 3A / 189 / 3 ( 492801518 ) Double Sided Pcb Adc ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 167 Nsc / 3A / 189 / 3 ( 492801518 ) Pcb Etc ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 168 Nsc / 3A / 189 / 3 ( 492801518 ) 1001-Z2c 10010Z2e ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 169 Nsc / 3A / 189 / 3 ( 492801518 ) Ps Positive Pcb ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 170 Nsc / 3A / 189 / 3 ( 492801518 ) Sn74al5245, B45196e 3105 ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 171 Nsc / 3A / 189 / 3 ( 492801518 ) Drilling Jig ( Consum- Able Item ) ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 172 Nsc / 3A / 189 / 3 ( 492801518 ) Ad 8350 Ar 20 ( Elec- Tronic Components ) ( As Per Letter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 And Adc-8 Modules ) Total No. Of Modules Is 35. 173 Nsc / 3A / 189 / 3 ( 492801518 ) Crystal Module 10 Mhg ( As Per Let- Ter Dated 11 / 01 / 2021, Nsc / 3A / 189 / 3 Was Made Into Lpcc-12, Gem-15 174 Nsc / 3A / 75 / 3 / 3 ( 492801553 ) Temeb 8704 175 Nsc / 3A / 78 / 5 / 1 ( 492801553 ) St 350 E & Its Accessories 176 Nsc / 4A / 167 / 4 / 1 ( 492801553 ) Hp 5200 Dtn Laser Printer Cnfxc33282 177 Nsc / 4A / 439 / 4 / 2 ( 492801553 ) Server Rack Mountable 178 Ap / 353 / 1 / 5 ( 492801553 ) Oscilloscope 179 Nsc / 4A / 131 / 7 / 1 ( 492801670 ) Infiniband With 4 Cable Set 180 Nsc / 4A / 439 / 4 / 1 ( 492801729 ) Server Rack Mountable 181 Nsc / 4A / 439 / 4 / 3 ( 492801729 ) Server Rack Mountable 182 Nsc / 3A / 203 / 7 / 1 ( 492801825 ) Emerson / Liebert Upstation Gxt2 Online Ups System 183 Nsc / 3A / 206 / 4 / 1 ( 492801825 ) Printer Inkject A10 Hp Of- Ficejet 184 Nsc / 4A / 127 / 3 / 1 ( 492801826 ) 6 Kva Ups 185 Nsc / 4A / 126 / 1 / 1 ( 492801565 ) Rack Mounted Pc 186 Nsc / 4A / 128 / 6 / 2 ( 492801565 ) Pentium 4 With Tft Moni- Tor 187 Nsc / 4A / 165 / 6 / 1 ( 492801565 ) Eye Piece And Uv Light 30 W 188 Nsc / 2A / 173 / 4 / 1 ( 492801565 ) Turbo V250 Pump 6 Cff 189 Nsc / 2A / 173 / 4 / 2 ( 492801565 ) Air Cooling Kit 190 Nsc / 2A / 173 / 4 / 3 ( 492801565 ) Controller For V250 191 Nsc / 2A / 173 / 4 / 4 ( 492801565 ) Varian Electro Preumatic 192 Nsc / 2A / 173 / 4 / 5 ( 492801565 ) Inlet Screen For V250, Dn- 100 193 Nsc / 2A / 206 / 4 / 1 ( 492801565 ) Water Bath Shaker With Clamp 194 Nsc / 3A / 228 / 6 / 3 ( 492801565 ) Aperture Conc. Control P / N 177495 195 Nsc / 2A / 278 / 1 / 1 ( 492801565 ) Edas -290 Gel Docu- Mentation System 196 Nsc / A / 369 / 4 / 1 ( 492801565 ) Ysi - 402 Steri Verticle Auto Clave 350X550 197 Nsc / A / 369 / 6 / 1 ( 492801565 ) Microscope 198 Nsc / A / 369 / 8 / 1 ( 492801565 ) Vertese Miser 199 Nsc / 2A / 396 / 2 / 1 ( 492801248 ) Calculator 200 Nsc / A / 310 / 5 / 2 ( 492801248 ) Allied Aluminium Size-8 Ft 201 Nsc / 2A / 81 / 6 / 1 ( 492801248 ) Esab Dura 0-10 Oxygen Regulator 202 Nsc / 2A / 81 / 6 / 3 ( 492801248 ) Esab Dura 0-10 Oxygen Regulator 203 Nsc / A / 101 / 2 / 1 ( 492801831 ) Rolling Mill B-85 120, 1991
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 5
37.
Educational and Research Institute #8978317 Technical Bid
Purchase Of Equipments For Analog Electronics Lab Eee Department , Equipments For Analog Electronics Lab , Supply, Testing And Commissioning Of Ammeter ( Mc 0-500 Microampere ) Specifications: Portable Moving Dc Portable Housed In Bakelite Case, With Pointer & Anti Parallax Mirror Scale Of 140 Mm Length Cl - 1 , Supply, Testing And Commissioning Of Ammeter ( Mc 0-10 Milliampere ) Specifications: Portable Moving Dc Portable Housed In Bakelite Case, With Pointer & Anti Parallax Mirror Scale Of 140 Mm Length Cl - 1 , Supply, Testing And Commissioning Of Ammeter ( Mc 0-50 Milliampere ) Specifications: Portable Moving Dc Portable Housed In Bakelite Case, With Pointer & Anti Parallax Mirror Scale Of 140 Mm Length Cl - 1 , Supply, Installation, Testing & Commissioning Ofdual Channel Dc Power Supply Specifications: Two Independent Isolated Outputs0-32V / 0-3 A Constant Voltage Operation: Line Regulation:<0.01%+3Mv Load Regulation = 0.01%+3Mv ( Rating Current = 3A ) ; = 0.02%+5Mv ( Rating Current>3A ) Constant Current Operation: Line Regulation: = 0.2%+3Ma Load Regulation: = 0.2%+3Ma Voltage Resolution: 100Mvcurrent Resolution: 10 M A Output On / Off - Analog Control ( Remote I / O ) For Output On / Off- Set View Function For Checking An Original V / I Setting During Output On - Key Lock Function - Tracking Series And Parallel Operation. Warranty:1 Year , Supply, Installation, Testing & Commissioning Of 2 Channel Dso Specifications: Bandwidth: 50Mhz ( Or Better ) , Real-Time Sampling Rate: 1Gsa / S, ( Or Better ) Analog Channels: 2, Display: 7” Tft Lcd Color Record Length: 100Kpoints ( Or Better ) , Time Base: 5Ns / Div To 50S / Div, Waveform Update Rate: 50, 000Waveforms / Sec, Acquisition Modes, Normal, Peak Detect Averaging, High Resolution Mode, Input Sensitivity : 500Μv / Div To 10V / Div, Vertical Control Knobs: Dedicated Controls Per Channel, Trigger Source: Ch 1, Ch 2, Line, Wave Generator And External, Trigger Types:Edge, Video, Pulse Width & Pattern Waveform Math: Fft, Ch1-Ch2, Ch1+Ch2, Ch1*Ch2, Ch1 / Ch2, Low Pass Filter Automatic Measurements: 24 Automatic Measurements Serial Protocol Analysis ( Optional ) : I²c, Uart / Rs232 Display Modes: Yt, Xy, Roll, Persistence Cursor Measurements: Inbuilt Function Generator: 20Mhz ( Sine, Square, Triangle, Ramp, Dc, Noise ) Frequency Response Analyzer Plot Gain And Phase Vs Frequency Interfaces Usb 2.0 Device Port And Usb 2.0 Host Port Voltmeter & Frequency Counter 3 Digit Voltmeter And 5 Digit Frequency Counter.Warranty:1 Year , Supply, Installation, Testing & Commissioning Of Function Generator Specifications: Output Function: Sine, Square, Triangle, Ttl, Sine & Square Frequency : 0.1Hz To 3Mhz; Triangle Frequency:0.1Hz To 1Mhz;Resolution: 0.1Hz Amplitude Range: 10Vpp ( Into 50? ) ; Stability: + / - 20 Ppm Accuracy: + / - 20 Ppm;Impedance: 50?+ / -10%;Attenuation: 40Db+ / -1Dbx1 Duty Control Range: 25% ~ 75% Below 1Mhz ( For Square Wave Only ) Output Control: On / Off Selector Ttl Output -Rise / Fall: = 25Ns At Max Output Level =3Vpp Warranty: 1 Year , Supply, Installation, Testing & Commissioning Of Cro Specifications: Frequency 30Mhz, Dual Channel, Crt Type: 6” Rectangular With Internal Graticule 8 X 10 Div. ( 1Div. = 1 Cm. ) .Accelerating Voltage: 2 Kv Vertical System- Bandwidth: Dc ( Ac 10Hz ) ~ 30 Mhz ( -3Db ) . Rise Time: = 17.5 Ns. Sensitivity: 5 Mv ~ 5 V / Div. ( ± 3% ) Vertical Mode: Ch1, Ch2, Dual ( Alt / Chop ) Add, Ch2 Inv Max. Input Voltage: 400 V ( Dc + Ac P-P ) . Input Coupling: Ac, Dc, Gnd. Input Impedance: ˜ 1Mo / / 25 Pf Horizontal System - Sweep Time: 0.2Μs ~ 0.5S / Div. ( ± 3% ) , X10 Mag.:20Ns ~ 50Ms / Div. ( ± 5% ) . Sweep Magnification: 10 Times. Max Sweep Time = 20 Ns / Div Trigger - Modes: Auto, Norm, Tv-V, Tv-H. Trigger Source: Ch1, Ch2, Alt, Line, Ext X-Y Operation - Sensitivity: 5Mv ~ 5V / Div. ( ± 4% ) . Phase Error: = 3° ( Dc~50Khz ) . X-Axis Bandwidth: Dc ~ 500 Khwarranty:3 Years , Supply, Testing And Commissioning Of Digital Multimeter Specifications: 3 ½ Digitlcd Display Dc Voltage : 0 –200Mv / 2V / 20V / 200V / 1000V Ac Voltage :0 –200Mv / 2V / 20V / 200V / 750V Dc Current : 0 – 2Ma / 20 / 200Ma / 20A Ac Current : 0 – 20Ma / 200Ma / 20A Resistance:200 / 2K / 20K / 200K / 2000K / 20M / 200Mohms Capacitance : 2Nf / 20Nf / 200Nf / 2Uf / 200Uf Frequency: 200Khz. Diode Test & Audible Continuity Test Facility. Warranty:1 Year , Supply, Testing And Commissioning Of Analog Ic Tester Specifications: Up To 20 Pin Ics Fail / Pass Loop Test To Check Stability Of Ic Loop Test To Check Same Type Of Ics Without Entering Ic No De-Energized Socket When Not Testing ( Avoids Damage Of Ics ) Op-Amps, Comparators, Timers, Analog Switches And Multiplexers, Cross-Point Switches, Voltage Followers, Regulators, Opto-Couplers And Isolators, Line Drivers And Receivers, Adc, Dac And Transistor Arrays. Warranty:1 Year
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
39.
Educational and Research Institute #8726736 Technical Bid
Purchase Of Lab Equipments For Mechanical Engineering Department -2 Digital Laser Holography System Consisting Of Laser Head, Stainless Steel Bread Board, Digital Camera And Digital Holography Software Specifications 1. Laser Head Na. Type: Diode Pumped Solid State Laser ( Dpss Laser ) Nb. Laser Power: 20Mw Nc. Laser Wave Length: 532Nm Nd. Minimum Image Processing Area: 1024×1024 Pixel N ( Including High Voltage Power Supply, Control Electronics And Accessory Cables ) N2. Stainless Steel Bread Board With Magnetic Steel Top Skin Na. Size: 90Cm×60 Cm N3. Digital Camera With Digital Holography Software Na. Camera Resolution: 3856×2764 Pixel Array Nb. Pixel Size: 1.67 Μm N 3 Thermocouple Wire Welder Specifications A. Type: Capacitor Discharge Nb. Input Power Supply: 16A, 220V Ac, 50Hz Nc. Energy Output: 60 Joules ( Maximum ) Nd. Welding Capacity: Nlow: 40Swg – 30Swg Thermocouple Wire ( 0.1-0.3Mm ) Nmedium: 30Swg – 24Swgthermocouple Wire ( 0.3-0.5Mm ) Nhigh: 24Swg – 19Swg Thermocouple Wire ( 0.5-1.1 Mm ) Nd. Cycle Time: Charging Time At Max. Energy Less Than 10 Sec Ne. Weld Cycle: Minimum 5 – 10 Welds / Min Nf. Suitable For Thermocouple Type : K, J, E, T, N, R, S, B N N 4 Regulated Dc Power Supply Specifications A. Dc Out Power: 600W Nb. Output Voltage: 0-120V Nc. Output Current: 0-5 A Nd. Input Power Supply: 16A, 250 V, 50 Hz Ne. Time Delay: 7 Sec Maximum From Power On Until Output Stable Nf. Output Noise: Nvoltage: Less Than 45Mv Peak To Peak Ng. Output Ripple ( Rms ) Nvoltage: Less Than 10Mv Ncurrent: Less Than 10Ma N
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Contract Date: Ref. Documents Contract Value : 4.30 Lakh
Government Departments No of Bidders 3
Madhya Pradesh View Result →
41.
Defence #8584575 AOC
Tender For Provision Of Roof Top Solar System At Nsry, Naval Base Karwar; 1 Design, Supply, installation, testing and commissioning of grid connected roof top solar generation system of capacity 500 KWp AC capacity with connected accessories all as specified and directed as per PS clause incuding specification as follows:- 2 (A) Supply, Installation, testing and commissioning of 500 KWp SPV system comprising of 540/545/535 Wp solar photo voltic modules/array of high efficiency made of mono crystalline silicon solar PV cells with supply and fix of terminal box on the module havingprovision for opening & replacing the cable etc.The general features of PV modules shall be as given below :- a) The module shall be made up mono crystalline silicon cells. b) The interconnected cells shall be laminatedin vacuum to withstand adverse environmental conditions. 3 c) The module frame is made of corrosion resistant materials, preferably having aluminium anodized finish. d) The minimum clearance between the lower edge of the modules & the developed ground level shall be 300 mm. e) Surge arresting devices to be provided at junction box and module shall be provided with bypass diode. f) The SPV module must be IEC 61215, IEC 61730 part I & part II, IEC 61701 certified from any of the accredited certifying agencies. g) Each solar PV module must be atleast five years warranted by manufacturer. Note :- (i) Makes of panel provided shall be as per MNRE specification/ standard and registered in ALMM. (ii) 0.25% spare qty of modules of total installed modules shall be provided by the contractor for repair / replacement purpose. (iii) Addln module shall be provided / installed by the contractor to meet specified power output incase if the same not achived during testing and commissioning without any extra cost. 4 (iv) Each PV module used in any solar power project must use a RF identification tag. The following information must be mentioned in the RFID used on each module:-(a) Name of the manufacturer of PV Module(b) Name of the Manufacturer of Solar cells(c) Month and year of the manufacture for solar cells and the module(d) Country of origin (make in INDIA only)(e) I-Vcurve for the module(f) Wattage, Im, Vm and FF for the module(g) Unique Serial No and Model No of the module(h) Date and year of obtaining IEC PV module qualification certificate(j) Name of the test lab issuing EC certificate(k) Other relevant information on traceability of solar cells & module. 5 (B) Module Mounting Structure (MMS) 6 Supply & fixing of the anti-corrosive factory made Aluminium Rail fixed over HDGI (Hot dip galvanised Iron) structure on the RCC Roof for fixing of PV modules by fixing of suitable size fastner, spring washer, stainless steel nuts & bolt. The minimum thickness of Aluminium & mounting stainless steel structure shall be as per IS 4759 & IS 2061-1992 respectively withstand the minimum wind load of 180 Km/hr. as per IS 875. The array structure shall be fixed properly using maintenance free earthing kit. 7 Note:- (i) The design of module mounting structure complying load withstand as per relevant IS alongwith fixing arrangement on roof shall be submittedby the contractor. (ii) The material shall be corrosion resistant and electrolyticaly compatible with material used in module frame. (iii)The fasteners should be of HDGI and should allow easy replacement of any module.(iv) The minimum clearance of the structure from the roof level should be 300 mm.(v) The tenderer shall not make any damages to roof/water proofing treatment while fixing solar module or mounting structure, if any damege occured shall be rectified to the satisfaction of GE without any extra cost to the Govt. 8 (C) Solar DC Cables:- 9 (i) Supply & laying of cable from solar module to inverter, 1 C X 4 Sq. mm Solar cable XLPO- Flexible tinned copper stranded class -5 conductors as per IEC-60228, Insulation– Cross linked Polyolefin, Outer sheath – Halogen free Polyolefin Black Colour as per site requirment as ISI marked in through PVC rigid conduit pipe by saddling as per direction of IEC. (For Solar Array DC supply connection). 10 (D) DC Combine box 11 A DC combine box inbuilt in the inverter shall be used to combine the DC cables of the solar module array with DC fuse protection for the outgoing DC cables to the DC distribution box. 12 (E) Array junction boxes 13 The number of junction boxes as per design given by OEM are to be provided in the PV array for termination of connecting cables. All wire/cables must be terminated through cable lugs. Copper busbar/terminated blocks housed in the junction box conforming to IP 65 degree of protection with EPDM rubber gasket to prevent water entry. Junction boxes shall be mounted on the MMS such that they are easily accessible and protected from direct sunlight & harsh weather. 14 (F) On Grid Power Conditioning unit ( Inverter) 15 Supply & installation of 415V 3-ph, 50 Hz, microprocessor DSP type grid connected Inverters which converts DC energy produce by the solar array to AC energy such that it synchronizes with the existing AC power source on site. Provisioning of power manager to get all parameter details. The Inverter shall have inbuilt MPPT (Maximum Power Point Tracker) feature so as to extract maximum power from PV modules & the MPPT units environmental testing should qualify IEC 60068-2 (1,2,14,30)/ Equivalent BIS standard. (The voltage variation of +/- 10% & frequency vatiation +/-3 Hz) Note :-(i) No of inverters shall be provisioned as per design given by OEM. (ii) Inverter should have internal protection arrangements against any sustainable fault in feeder line and against the lightning on feeder.(iii) Should have isolating transformer(iv) Inverter efficiency >97% (without inbuilt galvanic isolation) and >93% (with inbuilt galvanic isolation). (v) No load losses shall be less than 1% of rated power.(vi) The above quoted rate is inclusive of MS structure stand duly fixed on roof for placing inverter. 16 (G) Solar meter & Net meter 17 (i) Solar Generation Meter -01No (ii) 3 Phase Bi-Direction Meter-01 No at the main HT 110/11 KV takeover pointas per DISCOM requirement to be provided. (iii) The SPV plant to be connected with Grid supply where Captive both DG set also been placed. Therefore a provision of the reverse power relay shall be provided in the DG set incomer panel to both DG Set circuit. 18 (H) AC Distribution Board 19 (i) Supply & installation of 415V 3-ph 50Hz AC distribution board control AC power from PCU/ Inverter & provided by necessary surge arrestors system and solar energy meter (KWH) with IP65 protection and suitable capacity of MCCBs (One number incoming and One number outgoing). Note: ACDB shall be covered as per OEM design in such a way that structure must sustain 180 km/hr wind speed. The cost of provn for same is inclusive in quoted rate. 20 (J) AC Cables 21 (i)CABLE FROM INVERTER TO ACDB -4 C x 60 Sq. mm, Al Conductor, XLPE Insulated, Unarmouredas per site requirment fixed on wall with saddle (For AC power supply from Inverter to AC distribution board Panel). 22 (K) Protection 23 (i) The system shall be provided with all necessary protection like earthing, lightening & surge protection as per relevant standard. (ii) Protection relay for reverse supplyto 2.5 MW DG Set to be provided - 02 Nos 24 (L) Performance testing 25 Ratio between the theoretical energy outputs of the SPV plant is termed as performance ratio and is measured in accordance with IEC 61724. Based on prevailing climatic and temperature conditions in India, a performance ratio of 75% is expected for crystalline modules. 26 (M) Other Misc items 27 (i) Web Monitoring portal software -01 No. (ii) The report of genereted unit of solar power on monthly basis is to be submitted to the department. 28 (N) Earthing System 29 (i) Earthing system for Structure, DCDB, INVERTER, ACDB- 1C X 16sqmm, Copper Cable and1C X 35sqmm, Copper Cable as per site requirment and as per MNRE specifications to be provided. (ii) Earthing Pit- Earthing Chemical Kit - 2Mtr GI Rod + 20 Kg bag - 02 Nos. 30 (O) Lightening protection 31 Conventional Type lightning arrester- 25 Mtrs - 02 Nos, including 1C X 70 sqmm, Copper Conductor Unarmoured and 25X5 mm GI earth strip - LA earthing as per site requirment and as per MNRE specifications to be provided. 32 (P) Installation, Testing & Commissioning 33 As per safety norms of SERC/CEA to be provided. Satisfactorily testing and commissioning of the system is to be done by the contractor in presence of the rep of accepting officer and the report of the complete system is submitted to department. 34 (Q) O&M and Warranty 35 5 years from the date of commissioning to be provided. Warranty for 05 years means the entire system of roof top solar plant should work in healthy condition during this period. All the parts, which warrant repair/replacement in the opinion of the GE or as per site requirement shall be repaired or replaced accordingly. The: parts which will be replaced curing currency of warranty period shall be of the make/specifications provided originally by OEM. It is specifically brought out that the quoted rates deemed to be included repair/replacemer of each and every part of the Plant installed uncer the Schedule A during warranty period. 36 (R) Walkway/Water Piping/Hand Rail as per the site. 37 Note: The quoted rate deemed inclusive of the following:- 38 (i) Transportation charges with Transportation Insurance for the all material of on grid solar roof top system including loading & unloading at site from workshop. 39 (ii) Insurance for the complete system for the 5 Years. 40 (iii) Necessary Approval/NOC to be obtained from KPTCL. 41 (iv) Installation of Net metering and liasionwith KPTCL for pre commissioning testing to be done. 42 (v) As per performance obligation, the contractor shall maintain minimum capacity utilization factor (CUF) of 19%. The report shall be submitted by the contractor to accepting officer as per guidelines promulgated by SECI. (vi) Arrangement for installation of solar roof top system on roof of all blags (MEWR P-03, FAB P-04, DSS-06, SIMA AC Plant shall be made by contractor without any extra cost. 43 (a)The contractor shall be fully responsible for the upkeep, maintenance, and performance of the entire solar installation for a period of 05 (five) years from the certified date of completion of work. A sum equal to 1% (one percent) of the contract amount shall be retained from the Running Account (RAR)/Final Bill towards performance guarantee of the solar system. This amount shall be released only after the satisfactory completion of the five-year warrantee period. In lieu of the above retention, the Garrison Engineer (GE) may accept a Bank Guarantee Bond (BGB) from any Scheduled Bank or a Fixed Deposit Receipt (FDR) pledged in favour of the GE from any Nationalised Bank, valid for 05 years, covering the equivalent amount. In such a case, no deduction will be made from the RAR/Final Bill on this account. 44 (b) The contractor shall also submit a warrantee from the OEM/manufacturer or authorized system integrator on a non-judicial stamp paper, covering the solar panels, inverters, mounting structures, and associated components for a period of 05 (five) years from the certified date of completion. The warantee shall state that the system will remain free from defects, performance failure, corrosion, or degradation during this period. Submission of this OEM/system integrator warantee shall be mandatory prior to release of final payment. This shall, however, not relieve the contractor of his contractual responsibilities. The contractor shall remain liable to repair, replace, or rectify any failure or defect noticed during the five-year period at no additional cost to the Government 45 M&L for Cleaning of Grid connected type solar power plant of capacity 500 KWp and Panels made with mono crystalline PV Module and mounted on AL Structure complete installed against item no -01 herein before on roof top of Bldgs (MEWR BLDG P-03, FAB Bldg P-04, DSS 06, SIMA AC Plant) (comprising of all devices and accessories through out 12 months (twice in a month) for a period of 05 years after completion of work complete all as specified and directed. 46 M&L for Electrical Non comphrehensive maintenance of Grid connected type solar power plant of capacity of 500 KWp and Panels made with mono crystalline PV Modules and mounted on Aluminium Structure complete installed against item no -1 herein before on rooftop of Bldgs NRY ((MEWR BLDG P-03, FAB Bldg P-04, DSS 06, SIMA AC Plant)) comprising of all devices and accessories through out 12 months (Once in a month) for a period of 05 years after completion of work complete all as specified and directed.Note:- Any defective spare parts shall be replaced by the contractor without any additional cost during the waranty period of 5 years. 47 Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sq mm 3.5 core. 48 Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying/taking out cable and getting outin soft/loose soil all as specified and as directed. 49 Returning,filling in including spreading,levelling, watering and well rammingin layer not exceeding 25 cm in soft/loose soil all as specified and as directed. 50 Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and as directed. 51 Supply and laying of flexible DWC pipe of nominal diameter 100 mm under the ground and drawing the XLPE cable through the DWC pipe complete all as specified and as directed. 52 Supply, installation, testing and commissioning ofLT panel Outdoor type made out of 3.15mm thick CRCA sheet and mounted on PCC foundation weather/dust proof, factory made, IP-54 with Doble door openable shutters on both sides front and rear having locking arrangements, totally enclosed weather proof, powder coated over a coat of primer suitable for 440V, 3 Phase, 4 wire 50 C/s, aluminium bus bar of suitable size and capacity, AC supply, electrically connected as per norms and fitted including connecting up all out going MCCB/MCBs with suitable size of Aluminium bus bar or with stranded copper cable and fixing on suitable U shaped PCC platform comprising of the following accessories complete allas specified and directed by Engr in charge :Note: (a)The LT panel should be procured through CPRI approved manufacturer(b) The proper gland pacing for the cable entries to be provided.(c) The design of the LT panel to be taken prior approval from GE before procurement 53 (i) Aluminium bus bar with proper colour code -04 Nos. 1000 Amp Cap duly fixed on suitable size insulator, nuts bolts etc complete as per OEM recommendations.(ii) Indicator Lamp-01 Set (Set of three)(iii) Incomer MCCB, 415 Volt, 4 pole, 800 Amps, 50 KA rupturing capacity, Ics=100% Icu, thermal Magnetic release, with adjustable setting 80% to 100%- 02 No 54 Outgoing :- (i )MCCB, 415 Volt, 4 pole, 800 Amps, 50 KA rupturing capacity, Ics=100% Icu, thermal Magnetic release, with adjustable setting 80% to 100%- 01 No.(ii) Digital Voltmeter 0-500 Voltand Digital Ampmeter0-800 Amp with selector switches (iii) Complete wiring with suitable size copper cable, thimble etc. (iv) All outgoing MCCB Shall be connected through spreader and copper busbar not less than 10 mm thick strip. (iv) Platform for the feeder pillar board with PCC 1:2:4 15 Cm thick in foundation, Brick (Sub Class B)work inCM 1:6 ,rendering 1:6 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting legs of panel . The platform shall be of 450 mm height above ground level . 55 M&L for Earthing complete with Copper earth plate electrode 60cmx60cmx3.15mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Copper Strip of size 20x3mm size, by means of bolts, nuts, check buts and washers as earth lead protected by provision of GI medium grade pipe 40mm bore including provision 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 40mmx40mmx6mm with6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering of suitable lengthplaced on top edge of earth plate, common salt and charcoal filling, 15 CM alternate layer of charcoal and salt around all sides of earth platewith fixing arrangements, funnel, wire mesh and earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre complete all as per plate No 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. 56 Testing & Commissioing of Bi- Directional meter on 110/11 KV Main HTtaken points at Arga 110/11 KV Substation of Naval Base Karwar including taking permission from KPTCL/HESCOM for feasibility of 500 kwp roof to solar system complete all as specified and as directed.
Contract Date: Jan 12, 2026 Contract Value : 3.94 Crore
Statutory Bodies & Commissions/Committees No of Bidders 10
42.
Educational and Research Institute #8573789 AOC
Tender For Procurement Of Equipment For The Electronics Hub , Digital Multimeter , Digital Multimeter (Precision Industrial 4.5 Digit Multimeter) I Precision Industrial 4.5 Digit Multimeter Specifciation: Measuring Parameter: Ac Current, Ac Voltage, Capacitance, Conductance, Dc Current, Dc Voltage, Diode, Duty Cycle, Frequency, Resistance, Temperature Dc Voltage:1000V (Accuracy=±(0.05%+1)) Ac Voltage:1000V (Accuracy=±(0.7%+2)) Ac Band Width: 20Khz Dc Current:10 A (Accuracy=±(0.2%+2)) Ac Current: 10 A (Accuracy=±(1.0%+2)) Resistance:50 M? (Accuracy=±(0.2%+1)) Capacitance:9,999?F (Accuracy=±(1.0%+2)) Frequency:200Khz (Accuracy=±(0.005%+1)) Duty Cycle:99.90% (Accuracy=±(0.2% Per Khz+0.1%)) Operating Temperature: 20 °C To + 55 °C Warranty: As Per Standards , A Remote Display Automotive 4 Digit Display Digital Multimeter Kit Specification: Measuring Parameter: Ac Current, Ac Voltage, Capacitance, Conductance, Dc Current, Dc Voltage, Diode, Duty Cycle, Frequency, Resistance, Temperature Dc Voltage:0.1Mv-1000V (Accuracy=±(0.25%+2)) Ac Voltage:0.1-1000V (Accuracy=±(1.0%+3)) Dc Current:1Ma-10 A (Accuracy=±(1.0%+3)) Ac Current:1Ma-10A (Accuracy=±(1.5%+3)) Resistance:0.1O-50 M? Capacitance:1Nf-9,999?F Frequency:5Hz-50Khz Wireless Frequency: 2.4Ghz Ism Band 10 Meter Range. Power: Aa Batteries Three For Main Body; Two For Display Temperature: -40 °C To + 400°C . , 4 Digit Display Digital Multimeter : Measuring Parameter: Ac Current, Ac Voltage, Capacitance, Conductance, Dc Current, Dc Voltage, Diode, Duty Cycle, Frequency, Resistance, Temperature Dc Voltage:0.4Mv-1000V (Accuracy=±(0.5%+3)) Ac Voltage:0.4Mv-1000V (Accuracy=±(1.0%+3)) Ac Band Width:40Hz - 500Hz Dc Current: 400?-10 A (Accuracy=±(1.5%+3)) Ac Current: 400?-10 A (Accuracy=±(1.5%+3)) Resistance:400O-40 M? (Accuracy=±(0.5%+3)) Capacitance:9,999?F Operating Temperature:0°C +40°C Warranty: As Per Standards , Pcb Prototyping Machine Specification Ideal For • Pcb Prototyping • Pcb Assembly • Hands-On Learning • Minimum Trace Width : 0.2 Mm Print Area : 128 Mm X 116 Mm X 3 Mm Xyz Resolution :10 ?M X 10 ?M X 1 ?M Layer Capacity : Double-Sided Pcbs Substrate Thickness: 1-3 Mm Substrates : Rigid: Fr1 And Fr4 Operating Systems : Windows 7, 8, 10 (64Bit) Osx 10.11+ File Formats : Gerbers Connectivity : Wired Usb 2.0 , Infrared Camera 160 × 120 (19,200 Pixels) Thermal Resolution Or 240 × 180 Pixels (43,200 Pixels) Thermal Sensitivity: 0.06°C (0.11°F) /60 Mk At 30°C (86°F) Spatial Resolution (Ifov): 3.7 Mrad 1-Touch Level/Span Contrast Enhancement Cloud Storage Extended Temperature: 400°C/752°F Image Enhancement, Wi-Fi Connectivity With Additional Battery , Digital Ic Tester Specification: Display: 6 Digit Led Display New Equipment Power Consumption: 12Va Voltage: 220V+/-10%, 50 Hz Ac , Linear Ic Tester Specification: • Tests A Wide Range Of Analog Ics Such Op-Amp, 555 Timers · Tests A Wide Range Of Transistor Arrays, Analog Switches, Cross Point Switch · Tests A Wide Range Of 8 Bit Adc, 8 Bit Dac Comparators · Test By: Truth Table/Sequence Table Comparison · Zif: 28 Pin Dip Zif Sockets · Keys: 20 Touch-Keys Key Pad With Numerical & Functional Keys. · Display: 16X2 Lcd Display · Audio Alarm Indication. · Supply Input Voltage: 230V Ac , 5-Degrees Freedom Of Axis Robotics Arm With Controller, Drivers, Wireless Interface, Pc-Usb Interface, Manual Operation, Matlab, Labview Interface Provision (Sr.No.130) 1. 5 Degree Freedom Of Axis Robotics Arm Specification: A Mechanical Arm Based On The Esp32 Series Structure, Including The Clamping Freedom Of The Gripper. This Product Has A Total Of 5 Degrees Of Freedom, All Of Which Are Driven By A 30Kg.Cm High-Torque St3215 Serial Bus Servo. Each Servo Can Feed Back The Current Joint Voltage, Position, Current, Temperature, Load, And Other Information. And The Big Arm Adopts A 1:3 Reduction Group With Timing Pulleys, Which Greatly Improves The Effective Torque Of The Mechanical Arm On The One Hand, And Can Be Used To Avoid Damage To Structural Parts Caused By Excessive Loads On The Other Hand. 1. Esp32-Wroom-32 Main Controller 2. Servo Control Header 3. Oled Screen 4. Download Button 5. Reset Button 6. Type-C Port (Download/Uart Communication) 7. Usb To Uart Circuit 8. Rgb Led 9. 12V Dc Power Jack 10. Rgb Led Extension Port 11. Serial Bus Servo Control Circuit , Open Source Ai Robot Dog With Esp32 Controller Specification: Mechdog Is A Tiny But Powerful Robot Dog Equipped With An Esp32 Controller And 8 High-Speed Coreless Servos. Its Advanced Inverse Kinematics Algorithms Give It 1Impressive Agility And Movement Capabilities. Additionally, Mechdog Integrates Expansion Ports For Pm-Usha New Equipment Ultrasonic Sensors, Imu Sensors, And Other Sensors. It Supports Programming In Python, Scratch And Arduino. Extensive Learning And Development Resources Are Provided To Help You Easily Embark On The Journey Of Robotic Dog Development! Open-Source Esp32 Main Controller Powerful Coreless Servo High-Performance Wifi Vision Module Glowy Ultrasonic Sensor Extensive Expansion Interfaces Aluminum Alloy Frame Removable Lithium Battery , Controller Based System For Digital Power Electronics Applications Development: I/P & O/P Synchronization & Pwm Control, Current Sensor Dc & Ac (Hall Effect), Voltage Sensing Dc & Ac, Igbt Compatible Inputs , Inverter Based System For Power Electronics Application Development: 5Kw, 3-Phase Supply, 30Khz Switching Frequency, With Water Cooling System And Induction Coil Up To 1200 Degrees, Three Phase Annunciation And Pid Temperature Controller , Fpga Development Board , High End Oscilloscope Specification: Bandwidth: 100Mhz Analog Channels: 4 Digital Channels: 16 Real Time Sample Rate : 1 Gsa/S(Single Channel), 500Msa/S(Dual Channel), 250Msa/S(Full Channel) Memory Depth: 12 Mpts, 24 Mpts(Opt.) Waveform Acquisition Rate: 30,000Wfms/S(Max.) Offset Range: 1 Mv/Div To 499Mv/Div:±2V 500 Mv/Div To 10V/Div:±100V Vertical Resolution: 8 Bit Verical Sensitivity Range: 1Mv/Div-10V/Div Math: Add, Subtract, Multiply, Divide, Fet, Editable. , Variable Power Supply Specification: Triple Output Bench Power Supply Power Output Dc Output: 1. 0-6V ; 0-5A 2. 0-30V ; 0-1A 3. 0-30V ; 0-1A Load Regulation ± (% Of Output + Offset) Voltage : 0.01% + 2 Mv Current : 0.2% + 10 Ma Line Regulation ± (% Of Output + Offset) Voltage: 0.01% + 2 Mv Current: 0.2% + 10 Ma , Perpetual License For Ic Design
Contract Date: Jan 09, 2026 Contract Value : 35.00 Lakh
Boards / Undertakings / PSU No of Bidders 4
Maharashtra View Result →
43.
Educational and Research Institute #8573788 AOC
Tender For Procurement Of Equipment For The Electronics Makers Space , Digital Multimeter I.Precision Industrial 4.5 Digit Multimeter Specifiation: Measuring Parameter: Ac Current, Ac Voltage, Capacitance, Conductance, Dc Current, Dc Voltage, Diode, Duty Cycle, Frequency, Resistance, Temperature Dc Voltage:1000V (Accuracy=±(0.05%+1)) Ac Voltage:1000V (Accuracy=±(0.7%+2)) Ac Band Width: 20Khz Dc Current:10 A (Accuracy=±(0.2%+2)) Ac Current: 10 A (Accuracy=±(1.0%+2)) Resistance:50 M? (Accuracy=±(0.2%+1)) Capacitance:9,999?F (Accuracy=±(1.0%+2)) Frequency:200Khz (Accuracy=±(0.005%+1)) Duty Cycle:99.90% (Accuracy=±(0.2% Per Khz+0.1%)) Operating Temperature: 20 °C To + 55 °C Warranty:2 Years , Pcb Prototyping Machine Ideal For • Pcb Prototyping • Pcb Assembly • Hands-On Learning • Makerspaces Minimum Trace Width : 0.2 Mm Print Area : 128 Mm X 116 Mm X 3 Mm Xyz Resolution :10 ?M X 10 ?M X 1 ?M Layer Capacity : Double-Sided Pcbs Substrate Thickness: 1-3 Mm Substrates : Rigid: Fr1 And Fr4 Operating Systems : Windows 7, 8, 10 (64Bit) Osx 10.11+ File Formats : Gerbers Connectivity : Wired Usb 2.0 , Infrared Camera 160 × 120 (19,200 Pixels) Thermal Resolution 1 New Equipment Or 240 × 180 (43,200 Pixels) Thermal Resolution (Whatever Fits In Budget) Thermal Sensitivity: , Digital Ic Tester Display: 6 Digit Led Display Power Consumption: 12Va Voltage: 220V+/-10%, 50 Hz Ac , Linear Ic Tester Tests A Wide Range Of Analog Ics Such Op-Amp, 555 Timers · Tests A Wide Range Of Transistor Arrays, Analog Switches, Cross Point Switch · Tests A Wide Range Of 8 Bit Adc, 8 Bit Dac Comparators · Test By: Truth Table/Sequence Table Comparison · Zif: 28 Pin Dip Zif Sockets · Keys: 20 Touch-Keys Key Pad With Numerical & Functional Keys. · Display: 16X2 Lcd Display · Audio Alarm Indication. · Supply Input Voltage: 230V Ac , Pcb Short Locator System Pcb Short Locator System Short Circuit Locator • Inbuilt Computer With I5 Processor. • Integrated 12 Inch Touch Screen Industrial Monitor • Digital And Analog Functional Testing • Programmable Derive And Sense Levels • Versatile Clip Status Display With Voltage / Impedance / Pin Labels / Link Status Of Every Pin. • Advanced Qmax Signature Method Testing With Best Fit Curve Unique Software Algorithm • In-Built-Boundary Scan Controller And Optional Integrated Bs Test Software. • Greater Library Strength • Rcv Measurement And Oscilloscopes Utilities • Automatic Board Under Test Power Control. • Circuit Tracing Facility For Generating Net List Information. • Industry Standard Simulator For Developing New Device Program • Automatic Pullup And Pull Down For Testing Open Collector And Open Emitter Devices , High End Oscilloscope 250 Mhz High End Oscilloscope Specification: Analog Bandwidth: 250 Mhz Rise Time :=1.4Ns Number Of Channels : 4 Input Analog Channels Max. Waveform Capture Rate: 30,000Wfms/S(Vector Mode) 10,00,000Wfms/S(Ultra Acqu. Mode) Sample Rate : 1.25Gsa/S Max. Memory Depth: 50 Mpts Vertical Resolution: 12 Bits Peak Detection : Capture 1.6Ns Glitches
Contract Date: Jan 09, 2026 Contract Value : 14.91 Lakh
Boards / Undertakings / PSU No of Bidders 4
Maharashtra View Result →
44.
Coal and Mines #8547269 AOC
Retender For Request For Proposal Rfp For Installation, Commissioning And Maintenance Of Artificial Intellegance Labs In Selected Govt. Schools Of Latehar Request For Proposal Rfp For Installation, Commissioning And Maintenance Of Artificial Intellegance Labs In Selected Govt. Schools Of Latehar , Arduino Uno Atmega 328P-8Bit Avr Family Microcontroller Only Dip Controller Is Required , Arduino Nano (Soldered) Atmega 328P-8Bit Avr Family Microcontroller Pins Must Be Soldered , Breadboards Solderless 400 Points , Mini Breadboard Solderless 800 Points , Self Adheisive Bradboard Self Adhesive Proto Shield , General Purpose Soldering Board Fr2 A Grade Material (140*90Mm) , General Purpose Soldering Board Fr2 A Grade Material (80*55Mm) , General Purpose Soldering Board Female Berg Strip 40 Pins Single Row , General Purpose Soldering Board Male Berg Strip 40 Pins Single Row , 16X2 Ldc Display With Fixed I2c Dot Matrix Lcd Display With 16 Characters X 2 Lines , Usb Cable Set Usb Cable Set (Atob) , Usb Cable Set Mini Usb Cable Set , 9-12V Rechargable Battery 9V-12V Rechargable Battery Rechargable Battery Charger--2X , Resister Kit Resistor Kit (Different Value) , Capacitor Kit Capacitor Kit (Different Value) , Line Voltage Regulator 7805 , Line Voltage Regulator 7812 , Line Voltage Regulator 7809 , Water Pump Module Dc 12V,4W,Submersible Water Pump With , Piezoelectric Plate Normal Copper Based 4Cm Diameter , 8*8 Led Matrix Module Max 7219 Dot Led Matrix Module Mcu Control Led Display Module , Bluetooth Hc 05 Working Voltage 5 Volt , 7 Segment Led Display Led 4-Digit Display Module W/T Clock Point /4 Pin Dupont Line For Arduino. , Laser Diode 650Nm, 6Mm, 5V Dc, 5Mw Mini Laser Dot Diode Module , Ldr Module Photosensitive Ldr Light Sensor Module , Keypad Universal 16 Key Switch Keypad , Joy Stick Joy Stick Module For Arduino , Active Buzzer Small 5 Volt , Active Buzzer Big 5 Volt , Motor Driverl293d Moter Driver Module , Sound Play Back Module Isd 1820Voice Recording Module Or Equivalent , Dc Plastic Gear Motor With Thick Wheel 12V,150 Rpm,Side Shaft,Battery Operated , Nodemcu Esp8266 I2c,1 Wire,Plug And Play , Wemos D1 R2 Wemos D1 R2 With Wi-Fi,Esp 8266 , Vibrating Motor Vibrating Motor Opertating Voltage 1.5 To 3V , Alligator Connectors Multi Colour Alligator Connectors , Battery Clips With Dc Jack 9 Volt Battery Clips With Dc Jack , Hook-Up Wires Red & Black Set 100 Meters Each , Jumper Cable Male - Male , Jumper Cable Male-Female , Jumper Cable Female -Female , Rgb Leds Regular 5Mm 3-5 Volt Range , Leds (Red) Regular 5Mm 3-5 Volt Range , Leds (Green) Regular 5Mm 3-5 Volt Range , Leds (Blue) Regular 5Mm 3-5 Volt Range , Led(Yellow) Regular 5Mm 3-5 Volt Range , Leds (White) Regular 5Mm 3-5 Volt Range , 555 Timer Ic 555 Timer Ic 4.5V To 16 Volt , Diode Kit 1N 4006 , Diode Kit Zener Diode 4.6V , Zener Diode2.5V , Diode Kit 1N 4007 , Transistor Kit Bc 557 , Transistor Kit Bc-547 , Slide Switch Micro , Push Button Switch , Toggle Switch , Ir Sensors Obstacle Lm 393 Detectation Distance 2-30 C.M Detection Angle 30-40 Degree , Humidity Sensor Operating Range: 20 - 95 % Rhtemperature: 0 - 60 Celsiuspower Supply: 1.5V Ac (Max Sine) Operating Frequency: 500 -2Khz , Mq Series Mq-2 Smoke Detection , Mq Series Mq-3 Alcohol-Ethanol Sensor , Mq Series Mq-4 Methane Natural Gas Sensor , Mq Series Mq-5 Methane Liquified Gas Sensor , Mq Series Mq-6 Liquified Petroleum Gas Sensor , Mq Series Mq-7 High Sensitivity Co Carbon Monoxide Sensor Detector , Mq Series Mq-8 Hydrogen Gas Sensor , Mq Series Mq-135 Air Quality Sensor (Smoke Fast Response Stable And Long Life Simple Drive Circuit) , Ir (Transmitter) Receiver Tsop 1738 Switching Rate – 38 Khz , Ultrasonic Sensor Module Hc-Sr-04 Or Compatible Power Supply Quiescent Current Working Current Effectual Angle Ranging Distance Resolution Working Angle & Dimension , Pir Motion Detector Module High Digital Pulse When Motion Detected Low Digital Pulse When Idle /No Motion Detected Sensitivity Range (Upto 6 M) Power Supply: 5V – 12V , Pulse Rate Heart Sensor Pulse Rate Sensor Finger Based Wore On The Finger Or Earlobe Working Voltage 3-5V , Relay Module 5V 10A 2 Channel Relay Module , Relay Module 5V,10 A,-1 Channel Relay Module , Soil Moisture Sensor Fc-28With Lm 293 Comparator Operating Voltage 3.3V To 5 Volt Module , Touch Sensor. (Tp224) Capacitive Touch Sensor Module Ttp 22X Series Operating Voltage 2.4V To 5.5V , Metal Touch Sensor Module Ky-036 Or Equivalent Metal Touch Sensor Module , Rain Drop Sensor Rain Sensitive, Rain Drop Detection Sensor Module , Flex Sensor 2.2 Inches , Temperature Sensor Lm35 , Temperature Sensor And Humidity Sensor Moduledth 11 Voltage Range 3V-5V , Force Pressure Sensor Force Sensitive Resistor With A Square, 1.75 X 1.5 Sensing Area , Colour Recognition Sensor Tcs3200 Colour Recognition Sensor , Water Flow Sensor Arduino Compatible Water Flow Sensor 5V Dc Input , Ir Sensors Array For Line Following Ir Sensors Array For Line Following , 10000 Mah 5 Volt Power Bank , Rfid Reader – Tags Current: 13-26Ma/ Dc 3.3Vidle Current: 10-13Ma/ Dc 3.3V Sleep Current<80Uapeak Current<30Ma Operating Frequency: 13.56Mhz<30Ma Read Range Between 20 Cm To 1 M , Rf Modules Tx & Rx 315 Mhz Ask Frequency Range: 433.92/315 Mhz Supply Voltage: 3 – 6 V Output Power : 4 – 16 Dbmlow Power Consumption Easy Application , Stepper Motor With Driver Board 28By J-48 Uln2003 5V Stepper Motor+Uln2003 Driver Board , Dc Motor 12V, Dc Gear 150 Rpm , Servo Motors Position Servo Angle Based Metal Gear , Servo Motors Small Servo Metal Gear , Servo Motors Continuous Metal Gear Servo 360 , Servo Motors Small Servo Plastic Gear , 150 Rpm Bo Motor , L298p Motor Driver L298p Motor Driver Shield Or Relative Driver Shield , Robotics Diy Kit 4 Wheel Robotics Kit 4 Motor,1 Hard Plastic 4Wheel Chesis Set With Outer Cover For Wheel,1X Battery Pack,4X Wheel,1X Motor Driver Module And 1X Aic Controller , Centrifugal Kit-Mechanical Kit Includes Diy Building Parts Like Beam, Gear, Axel, Bush, Connector Peg , Ferris Wheel Kit-Mechanical Kit Includes Diy Building Parts Like Beam, Gear, Axel, Bush, Connector Peg , Pull Back Car Kit- Mechanical Kit Includes Diy Building Parts Like Beam, Gear, Axel, Bush, Connector Peg , Sling Shot Kit- Mechanical Kit Includes Diy Building Parts Like Beam, Gear, Axel, Bush, Connector Peg , Forklift Kit- Mechanical Kit Includes Diy Building Parts Like Beam, Gear, Axel, Bush, Connector Peg , Revolver Kit-Mechanical Kit Includes Diy Building Parts Like Beam, Gear, Axel, Bush, Connector Peg , Try Cycle Kit- Mechanical Kit Includes Diy Building Parts Like Beam, Gear, Axel, Bush, Connector Peg , Bird Balancing Kit Mechanical Modular Kit Kit Includes Diy Building Parts Like Beam, Gear, Axel, Bush, Connector Peg , Diy Drone Kit , 3D Printerprinter Type: Fdm (Fused Deposition Modelling) Minimum Dimensions: 256Mm*256Mm*256Mmbuild Volume) Build Size 4Pla Can Put Together And Can Printer Simultaneous Nozzle: 0.3Mm To 0.4Mm. , Filament For 3D Printer Compatible 700/1000 Grams Filament , 600Va Ups Dedicated Ups For 3D Printer Backup , Big Hexa Frame 12 Or More , Big Hexa Frame Blade , Mini Hexa Frame 6 Frame , Hexa Frame Blade Mini Hexa Frame , Pliers External Straight , Pliers Nose Circlip Plier , Pliers Long Nose Plier , Pliers Combination Mini Plier , Pliers Wire Stripping Pliers , Pliers Bent Nose Plier , Pliers Needle Nose Pliers , Tweezer Set 6 Pic Non Magnatic Tweezer Set (6 Inches) , Ball Pein Hammer , Steel Shaft Claw Hammer Claw Hammer Steel Shaft , Allen Key Set 9 Piece Ring Imperial Allen Hex Key , Drill Machine Set Drill Machine Set With Accessories Hammer/Screw And Clock Wise And Anti Clock Wise 350Watt , Precision Screw Driver Set 6 Piece Precision Screw Driver Set , Wire Strippers , Screwdriver 40 Pc Multi-Purposescrew Driver , Cordless Rotatary Multitool Set Cordless Rotary Multitool With All Cutting,Grinding Polishing,Engraving And Drill Bits,Speed Adjustable Upto 3000 Rpm Battery Type:-Li-Ionvoltage /Current 8-10V,0-2 Amp , Drill Bit Set High Quality 13 Pcs, Hss Drill Bits Set For Wood, Iron, Aluminium, Plastic Etc. , Flexible Cutting Mat A3 Size With Marked Pattern And Grids (18 X 12) (In Stock) , Hot Glue Gun Range In Open Space (Standard Conditions) 230 To 280 Degree Celsius , De-Soldering Pump 4X , Soldering Flux (Paste), 4X , De-Soldering Copper Braid (Solder Wick), 4X , Soldering Wire: 20/22Awg Soldering Wire With Rosin Core Flux 100 Grams)4X , Soldering Kit Variable Wattage Of Soldering Iron: 15-30 Watts/ 230 Voltssoldering Iron Temperature Range: 280°C To 450°C, , Adapters Dc Power Adapter With -12V 2Amp , Adapters 9V, 2 Amp , Electric Screw Driver Set Electric Screw Driver Set Includes Battery, And Screw Set , Dual Temp Heat Gun 1800 W Dual Temperature Heat Gun , Soldering Helping Hand Adjustable Crocodile Holding Clamps/Clip, Soldering Iron Holder,Led Magnifying Lens , Return Measuring Tape 5Mx19mm , Stainless Steel 12”/ 150 Mm Rule , Digital Vernier Calliper 150 Mm / 6” Digital Vernier Calliper , Spirit Level 12” Spirit Level , Digital Pen Electric Tester Voltage Tester , 6X4 Feet Alkon Alokn Board Mounted On Ply,Size Will Be 6X4 Feet,With Connector Hook , Digital Multi Meter Digital Multi Meter Voltage Current Resistance-7 Functions + 19 Ranges To Cover Dc Voltage 200Mv To 1Kv, Ac Voltage 200 V - 750 V, Dc Current 200 ?A - 10 A, Resistance 200 -2 M Ohm And Transistor & Diode Test , Glue Stick 11Mm X 200Mm Hot Melt Glue Stick , Nuts, Bolts, And Screw Spec M4x12mm, M4x20mm, M5x16mm, M5x25mm, M6x20mm , Cable Tie. Small (Pack Of 100) , Cable Tie. Medium (Pack Of 100) , Cable Tie. Big (Pack Of 100) , Sand Papervarious Grit-80 , Sand Paper Various Grit-100 , Sand Paper Various Grit- 120 , Power Strips Adapters 5 Plug With Safety Fuse Standard Quality Extension 3M Wire , Bulb Holders Regular Hanging Bulb Holder.9X , Electric Wires Twisted Red Black Pair , Usb To Dc Jack For Battery Bank , Safety Goggles (Without Led Torch) Safety Goggles For Chemical Splash And Smoke From Soldering , Safety Gloves Pairs Latex Coating Gloves (Medium Size) , Safety Mask Filtering Efficiency Ranging 80 Percent When Tested Against 0.3 Micron Sodium Chloride Particle. , E-Lt Kit , P-Lt Ekit , Xtrem Kit , Computers Mini Pc In One , Intractive Panel , Gears Cutout Acrlylic Differet Colour 10 , Bulb Design Branding 4X2 Feet, Cutout , Acrylic Board3x1.5 Feet , Sinages On Sunboard 2X1 Feet , I Am Innovator Acrylic 8X1.5 , Acrylic Humaniod Robot 4X3 Feet , Acrylic Art Work 10X10 Art Work , Sunboard 4X2 Feet , Work Table Metal (Frame And Legs) Ply Pre-Laminated Top4x2.5 Feet,Square Inrectangleshape , Work Table For 3D Printermade Up With 18Mm Ply 5X3 Feet With Storage Cupboard, And Rack On Top,Mounted With Metallic Stand , Soldering Station With Utility Shelf Metal (Frame And Legs) Ply Pre-Laminated Top 6X4 Feet, With Softboard And Tuplight Stand On Top , Stools Matallicwith Cushion Standard Height , Almirah Made Up With Ply With Lock 6X3 Feet , Computer Table Mdf Pre Laminated 3X2 Feet With Power Supply Board , Tool Board Mounted On Ply 6X4 Tool Board For Hanging Tools , Game Table 8X4 Feet Made Up With Ply And Metsallic Stand With 80Mm Boundry , White Wash & Putty 600 Sq Feet 2 Colour On Wall , Hr For Lab
Contract Date: Dec 02, 2025 Contract Value : 77.63 Lakh
Government Departments No of Bidders 8
45.
Communications and Information Technology  #8498688 AOC
Bids Are invited for Pdg High Energy Efficiency Solar Photovoltric Module Of 15 Kwp Or Above Manufactured In India Etc Complete - Solar Photovoltric Module Conversion Efficiency Shall Not Less Than23 Percent At Stc , Power Conditioning Unit Pcu Suitable For 15 Kwp Solar Photo Voltricpower Generation System Etc As Required - Ac Voltage And Current In All 3 Ohases And Comulative Ac Output Power Etc , Module Mounting Structure On The Roof Top Solar Plant Generation Unit Shall Be Installed - Using Supporting Aluminium Or Galvanized Ms Structure Having Clearance Of 2 Point 4 Meter Above The Terrace Level Etc , Real Time Online Web Interfaced Data Monitoring System Complete With Accessories Of 15 Kwp Solar Photovoltric Module Etc - Power Produced And Other Parameters As Per Standard Practices Suitable For 15Kwp Solar Photo Voltaic Generation System Etc , Array Junction Box And Main Junction Box With Ip 65 Protection And Termination Arrangement For Incoming And Outgoing Cable - Surge Arrestors And Suitable Reverse Blocking Diodes Isolation Switches Isolate The Dc Input To Inverter Etc , Lightning Surge Voltage Protection Earthing Protection Etc - Grid Islanding Suitable For 15Kwp Etc , Cables Connections And Interconnections By Required Size Ir Or Uv Protected Xlpe Insulated Copper Conductor Cable - 1 Point 1 Kv Grade Armored Power And Control Cables Isi Marked Along With Supplying And Fixing Of Necessary Channel Or Conduit Etc , Dc Distribution Board And Ac Distribution Panel Board Ip65 Free Standing, Metal Cladded Etc - Having Copper Bus Bar Having Required Protection And Control Gears Connection-Interconnection Etc As Required Suitable For 15Kwp Etc Total Quantity : 8
Contract Date: Ref. Documents Contract Value : 9.06 Lakh
Government Departments No of Bidders 2
Contract Date: Ref. Documents Contract Value : 24.40 Lakh
Government Departments No of Bidders 1
Madhya Pradesh View Result →
47.
Defence #8268559 AOC
Tender For Provision Of Roof Top Solar Plants 125 Kw At Certain Buildings At Mil Station Gaya; 1 Design, procure, erection, installation, testing and commissioning including connecting to local utility grid; Roof top On-grid Solar Photovoltaic Plant of 50kWp capacity including Solar Photovoltaic Modules, DC Cabling, Module Mounting Structures, Array Combining Boxes, Lightning Protection of SPV modules and other accessories, Central Inverter as Power Conditioning Unit, Weather Station and Data Monitoring System all as per detailed specifications given in Particular Specification, latest MNRE/IREDA guidelines and directions, meeting the Domestic Content Requirement (DCR), consisting of all requisite accessories (BOS-Balance of System) and incuding the following main componenets:-Make In India: Solar Panel & Solar Cell: Monocrystalline PV Modules & PV Cells : TATA / BHEL / HMV / Waaree Energies Ltd / Vikram / Adani / Emmvee / Premier Energies Solar Invertor/ Power Conditioning Unit (PCU) : DELTA / SUNGROW / GROWATT / POLYCAB / HAVELLS / FIMER.Note: 50 KWp (i.e. 50 KW AC out put) (02 Nos) solar roof top plant will be installed at Demo Coy and DSC Bldg including annualmaintenance cost 2 years till completion of defect liability period. The completion of work (Phase-I ) after installation ,testing and and commissioning of plant.During defect liability period, contractor will carry out following activity:-The scope include:(i). Cleaning once in a month. (ii). CompetentpersonsthroughAuthorizedServicecentrewillalwaysbe deputed to respond the calls who are aware of safety and statutory norms.(iii). For monthlycleaningand preventivemaintenanceactivity - team of one expert Engineer &two semi-skilled technicians will be deputed and they will submit monthly report. (iv).sensors & Data Logger once in 2 month:- (a) Sensor healthiness.(b). Optical Fibre Communication loop healthiness(c). Data logging accuracy(d). Frequency- Monthly (v). Reliability Centred Maintenance once in a month:- (a).Preventivemaintenance ofthecompleteplant-Stringhealthiness, presenceof burnmarksorlocalhotspots,Inverterchecking, checkingof healthiness of power distribution panels etc. (b). Integrity improvement (proper identification of strings and all cables)(c). Frequency-Monthlyvi. Breakdown Calls:- (a).Toberespondedwithintwohrsandresolutionwithin24to48hrsfor minor issues like string problem etc. on a working day.(b). Call log notification time will start from the time a mail has been triggered by the Solar Log system or Customer reports any abnormality(c). Visits of any OEM Engineer will be organized vendor/contractor wherever specialized input is required for addressing the breakdowns at site without any extra cost after completion of 2 years of Defect Liability Period,contractor will provide additional maintenance of the Solar Plant for further 3 years as per scope of maintenance referred above (i.e. total maintenance period 2+3 years).Note:- (Inverter capacity 25/ 50KW as applicable with 05 years warranty) 2 Sl Item 1 Contd….(A) Mono Crystaline Silicon Solar Photovolaic Modules of500 Wp or more (module power and number of modules to be selected according to available roof top area & adequate walkway), having cell efficiency more than18% under standard conditions, form fill factor more than 0.76, plant performance ratio > 75%, made of high transmitivity glass front surface and it shall give high encapsulation gain (transmittance above 90% and bending less than 0.3%). The modules shall have the folling features :-(a)The electrical parameters of SPV modules under standard test condition of irradiance 1000 W/sqm, AM 1.5 Spectrum and temp 25 degree Celsius shall be as under:-(i) Max Peak Power Pmax : 500 Wp or more(ii)Voltage at Max Power : > 39 V(iii) Current at Pmax : > 9 A(iv) Short Circuit Current : > 10 A(v)Open Circuit Voltage : > 47 V(vi) Module Efficiency : > 19 %(b) Rated output of the modules shall have positive tolerance of 3-5% and no negative tolerance is allowed.(c) It shall perform satisfactorily in RH 85% with temperature up to +85 degree C and should withstand wind of 200 kmph on the surface of panel.(d) PV modules shall be warrented for their output peak watt capacity, and it shall not fall of its initial value below 90% in first 10 year end and 80% after the end of 25 years. 3 Sl Item 1 Contd….(e) Each module shall have RFID tag encapsulated with solar cell bearing following details :- (i)Name of Manufacturer of SPV Module(ii) Name of Manufacturer of Solar Cell(iii)Month and year of Manufacturing (seperately for cell and module)(iv) Country of Origin (both cell and module)(v)Peak wattage, Im, Vm and fill factor of the module(vi) Date of year of obtaining IEC PV module qualification certificate including the test lab issuing IEC certificate.(vii)Unique serial no and model no of module(viii)IV curve of module(f)The temperature coefficient of power for the module shall not be more than 0.50% per degree Celcius.(g) Every module must have bypass diode of suitable capacity.(h) PV module must confirm to latest edition of IEC 61215/ IS 14286. In addition the modules must confirm to IEC 61730 Part I and II for construction and testing & safety qualifications and confirming to IEC 62804 PID.(j) It shall also be in confirmity to latest minimum technical specification issued by MNRE & IREDA from time to time. Modulesshould be of MNRE & IREDA approved companies and as per latest IEC/IS standards.(k)Provision of earthingand earth strip / cable etc for earth of solar PV module/ array etc as per latest IS/MNRE & IREDA norms to be provided and cost of the same is deemed to be included in the item and no extra amount will be paid to the contractor on this account. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474). 4 Sl Item 1 Contd….(l)RFID reader is to be provided by contractor(m)Both PV cells and SPV modules shall be make in India. 5 (B)Junction Boxes : Supply and fix junction boxes of suitable Nos (as per design)/ OEM recommendations inputs and suitably rated output having separate DC fuses for both (+) & (-) on input and isolator on output terminal for each string. Each junction box must have a spare input terminal. The junction boxes shall be dust and vermin proof and water proof made of FRP/ Thermo Plast with IP 65 protection in compliance with IEC 62208 and shall be UV resistant, fire retardant. It shall have surge protection and maintenance free earthing as per relecant standard. The junction box shall have suitable arrangement of the following :-(a)The strings are required to be connected to the copper bus bar through individual fuses.(b) Provide arrangement for disconnection (DC dis-connection switch) for each SJB/ SCB.(c)Provide a test point for each sub group for quick fault location and to provide group array isolation.(d)Each array box shall be of relevant IEC standard.(e) Each array junction box shall have suitable bypass & reverse blocking diodes for maximum DC blocking voltage of 1000V with suitable arrangement of its connection. Reverse blocking and bypass diodes shall work for extreme temperaturesand shall have efficiency of 99.98% confirmed by appropriate IEC standard.Make : As per OEM 6 Sl Item 1 Contd…(C)DC Cables : Suitable size of XLPE insulated tinned Copper cable (min 6 sqmm of size) of Solar grade, 1100 Volts and UV resistant for outdoor installations confirming to IEC : 60227/15694 & 60502/ IS : 1554 (Pt I&II) and shall be as under :-(a) All cables and connectors for use of installation shall be of Solar grade which can withstand harsh enviromnetal conditions including high temperature, UV radiations, rain, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/ IS.(b) All the cables / wires shall be provided with UV resistant printed ferrules for DC side.(c) The size of the cable shall be such that avearage voltage drop at full power from PV module to inverter shall be less than 1.5%.(d)Cable batch No, drum No, IS code and size and make shall be metioned on every one meter or as per OEM practice.(e) The wiring of the module interconnection shall be in UPVC/HDPE pipe of suitable size. (f) The cost of interconnecting DC Copper cable, MS cable trays, and earth work for trenches/ MS cable trays suitable to accommodate Solar grade cables from SPV module upto inverters are included in the item. 7 Sl Item 1 Contd….(D)Module Mounting Structure (MMS) : Design, procure, fixing, support structure made of hot dipped galvanised with min 85 micron thickness including necessary PCC foundation and associated work (cutting, grouting, PCC filling, dispoing waste material, etc., complete) and fixing mounting arrangement suitable for SPV modules so as it can withstand wind speed of 200 km per hour. The mounting structure is to be installed at RCC Roofs and the array structure has to be so designed that maximum load is directly on roof beams and columns. It shall also occupy minimum space without sacrificing the output of SPV panels & adequate space between the arrays shall be available for easy cleaning and maintenance. Nuts, bolts, mounting structure including module mounting structure shall have to be adequately protected from the atmosphere and weather prevailing in the area. All the fastners shall be of Stainless Steel of grade SS316. Notes : (a) Two numbers of anti theft fastners of Stainless Steel on two diagonally opposite corners of each module shall be provided. (b) The modue mounting structure shall be of fixed to provide maximum generation. (c) MMS design shall be supported with Stadpro Report vetted by Third Party (Gov Institute) and submitted for the approval of the Acepting Officer. (d) The height of Roof top MMS shall be as per latest MNRE & IREDA guidelines. 8 Sl Item 1 Contd….(E) Lightning Protection for PV Array : Design, procure and fix lighting arrestor system cofirming to IS/ IEC-62305 (Part 1 - 4) on the roofs. The air terminalshall be fixed at the top of GI elevation pole with base so as to be at least two meter above the structure to be protected. Its height above roof level shall be depend upon the level of protection and protection radii required. Notes : (a) The cost of all equipments, Copper strip upto earth test point, etc., shall be deemed to be included in this item. (b)The cost ofearthing for lightning protection (F) Power Conditioning Unit : Procure, fixing, testing and commissioning of 50 KW AC (nominal power), Solar power inverter suitable to convert DC power of Solar PV module/ array to AC for further feeding to grid confirming to IEC : 61683 for efficiency, IEC : 62109-1 or equivalent for safety and IEC : 62093 for reliability. The input DC & output AC technical specification of Inverter are as under :-.Input (DC)(a)Max Absolute DC input Voltage : 1000 Vb)Start-up DC input voltage : 360 - 500 V (Default 420V)c)Operating input DC voltage range : 300 - 950 V(d)No of independent MPPT : One(e)MPPT input DC voltage range at Pacr :480 - 800 V DC(f) Max input DC Current : 110 A(g)Maximum input short circuit current : 160 A(h)No of Protected DC inputs : 8-20 9 Sl Item 1 Contd….(G)Output AC(a)AC grid connection type :3Phase (4W + PE)(b)Nominal Power at unity PF : 50 kW(c)Max AC output power : 50 KW(d)Max AC output Apperant power : 50 KVA(e)Max AC output Current : 70 A(f) Max AC fault current : 1.25 to 2.5 times of rated current(g)Nominal Output Voltage : 415 V(h)Output voltage range : 415 V ± 20%(j) Output Frequency : 50 Hz± 3Hz(k)Power factor : > 0.995(l) Harmonic Distortion Current : < 3%(m) Efficiency : > 98%(n)Standby operation consumption : < 1.5 W 10 (p)Operating temperature upto 85 degree centigrade(q)The inverter shall have minimum IP-67 protection, ground fault monitoring, grid monitoring, protection for anti-islanding, DC reverse polarity, AC and DC short circuit current and over current, AC and DC over voltage and over temperature. (r) The inverter shall adjust voltage and frequency levels to suit the grid.(s)The inverter shall be self commulated with Pulse Width Modulation (PWM) technology and shall be capable of synchronise maximum with in one min.(t) Maximum Power Point Tracker (MPPT) confirming to IEC 62093 shall be integrated in the inverter to maximise the energy drawn from the PV array(u)Monolithic design of inverter is not permitted.(v)The inverter shall have suitble nos of protected inputs (asper design) and outgoing shall be protected by ACB/MCCB. 11 Sl Item 1 Contd….(x)The inverter should have MODBUS, PROFIBUS, ETHERNET common ports.(y) The inverter shall include appropriate self protection and self diagnostic feature to protect itself and the PV array from the damage in the event of inverter componant failure or from parameters beyond the inverters safe operating due to internal and/ or external causes. Inverter shall have protection arrangement against ground leakage faults, over voltage, (SPD) & over current. Inverter shall have arrangement for adjustment for adjusting DC input current and shall trip against sustainable fault down stream and shall not restart till fault is rectified.(z)The inverter should have provisions of Galvanic isolation, anti-islanding protection (IEEE 1547/UL 1741) equivant IS and lightening.(aa) PCU must have the feature to work in tandem with other similar PCUs and be able to be successively switched ON and OFF automatically based on solar radiation variations during the day. 12 Sl Item 1 Contd…. (H) Balance of System (BOS) Items/ Components :- The BOS items/components of the SPV power plants/ systems deployed under this project shall conform to the latest edition with certificate of IEC or equivalent BIS Standards/ MNRE specifications/ as specified in Para 1.01 of Minimal Technical Requirements/ Standards for SPV System/ Plants to be deployed during this financial year under the programmes of MNRE available on MNRE website as on last date of quoting of tender.Notes : (a)The contractor must visit the site before quoting the rates for this item to asses the site condition so as to decide up on location and layout of SPV, placement of inverter, length of DC cables, lightning arresters, etc., complete.(b) The contractor shall submit complete scheme including electrical diagram of the work, schematic diagram, SPV module layout, placement of LAs, Civil work,etc., complete as per IREDA latest guidelines as applicable, Relevant IEC/IS norms to the GE for approval with in one month of date of commencement of the work. 13 Sl Item 1 Contd…. (c) The rate quoted is deemed to be inclusive of the all protection system including surge, lightning arresters and necessary earthing all as specified and directedd) Quoted rates inclusive of necessary faciility for monitoring of solar power generation through app along with necessary sim card and recharge for 2 years(e)Training : On successful commissioning of the plant, training shall be provided on plant operation and maintenance to a team (Engineers and technicians/ operators) as nominated by department for minimum one month. 14 (J) Operation and Maintenance for preventive maintenanceof 50 kwp x 2 plants (Demo ii coy & 5 DSC pln) Roof top solar plant for a period Year of 3 years after 2 year Defect liability periodfrom project completion date:The scope include:i. Cleaning once in a month. (ii). CompetentpersonsthroughAuthorizedServicecentrewillalwaysbe deputed to respond the calls who are aware of safety and statutory norms.(iii). For monthlycleaningand preventivemaintenanceactivity (one expert engineer and two semi-skilled technicians will be deputed and they will submit monthly report.(iv). sensors & Data Logger once in 2 month a.Sensor healthinessb. Optical Fibre Communication loop healthinessc. Data logging accuracyd. Frequency- Monthlyv. Reliability Centred Maintenance once in a montha.Preventivemaintenance ofthecompleteplant-Stringhealthiness, presenceof burnmarksorlocalhotspots,Inverterchecking, checkingof healthiness of power distribution panels etc.b. Integrity improvement (proper identification of strings and all cables)c. Frequency-Monthlyvi. Breakdown Callsa.Toberespondedwithintwohrsandresolutionwithin24to48hrsfor minor issues like string problem etc. on a working day.b. Call log notification time will start from the time a mail has been triggered by the Solar Log system or Customer reports any abnormality c. Visits of any OEM Engineer will be organized vendor/contractor wherever specialized input is required for addressing the breakdowns at site (without any extra cost).vii. Rate to be included for( 02+03) years Operation andMaintenance.viii.Retain 5% of amount quoted against this item till Total 02+03=05 yearsafter completion of date .However this amount could be released after submission of FDR/BGB in favour of concerned GE.Note:- For items : Solar cell and Solar Panel shall be Make In India.- The output specified will be AC output of Solar Power Plant.-The system/ RMU/ Busbar will be compatible with infrastructure of State Electricity Board.-MNRE/NSRE approved vendor will vet the design, supervise execution and will commission Solar Plant Work and will also certify the design output (agreement between authorised vendor and contractor to be submitted).-Necessary compatibility certificate of healthiness of Solar Power Plant infrastructure with State Electricity Board infrastracture shall be submitted by representative of State Electricity Board through the contractors.- During defect liability period one expert engineer and two semi skilled techicians will also monthly visit to provide service and shall submit monthly report to Engineer-in-charge.- The Contractor isrequiredto quotedthierRatefor Operation and Maintenance of Total 02+03=05 years andNo extraamount shall be paid on this acount. 15 Design, procure, erection, installation, testing and commissioning including connecting to local utility grid; Roof top on car parking structure, On-grid Solar Photovoltaic Plant of 25 kWp capacity including Solar Photovoltaic Modules, DC Cabling, Module Mounting Structure, Array Combining Boxes, Lightning Protection of SPV modules and other accessories, Central Inverter as Power Conditioning Unit, Weather Station and Data Monitoring System all as per detailed specifications given in Particular Specification, latest MNRE/IREDA guidelines and directions, meeting the Domestic Content Requirement (DCR), consisting of all requisite accessories (BOS-Balance of System) and incuding the following main componenets:-Make : (MAKE IN INDIA)Monocrystalline PV Modules & PV Cells : TATA / BHEL / HMV / Waaree Energies Ltd / Vikram / Adani / Emmvee / Premier EnergiesSolar Invertor/ Power Conditioning Unit (PCU) : DELTA / SUNGROW / GROWATT / POLYCAB / HAVELLS / FIMERNote:including annualmaintenance cost 2 years till completion of defect liability period. The completion ofmain work after installation ,testing and and commissioning of plant.(25KW AC O/P)Note:- (Inverter capacity 25/ 50KW as applicable with 05 years warranty) 16 Sl Item 1 Contd….(A) Mono Crystaline Silicon Solar Photovolaic Modules of500 Wp or more (module power and number of modules to be selected according to available roof top area & adequate walkway), having cell efficiency more than18% under standard conditions, form fill factor more than 0.76, plant performance ratio > 75%, made of high transmitivity glass front surface and it shall give high encapsulation gain (transmittance above 90% and bending less than 0.3%). The modules shall have the folling features :-(a)The electrical parameters of SPV modules under standard test condition of irradiance 1000 W/sqm, AM 1.5 Spectrum and temp 25 degree Celsius shall be as under:-(i) Max Peak Power Pmax : 500 Wp or more(ii)Voltage at Max Power : > 39 V(iii) Current at Pmax : > 9 A(iv) Short Circuit Current : > 10 A(v)Open Circuit Voltage : > 47 V(vi) Module Efficiency : > 19 %(b) Rated output of the modules shall have positive tolerance of 3-5% and no negative tolerance is allowed.(c) It shall perform satisfactorily in RH 85% with temperature up to +85 degree C and should withstand wind of 200 kmph on the surface of panel.(d) PV modules shall be warrented for their output peak watt capacity, and it shall not fall of its initial value below 90% in first 10 year end and 80% after the end of 25 years. 17 Sl Item 2 Contd….(e) Each module shall have RFID tag encapsulated with solar cell bearing following details :- (i)Name of Manufacturer of SPV Module(ii) Name of Manufacturer of Solar Cell(iii)Month and year of Manufacturing (seperately for cell and module)(iv) Country of Origin (both cell and module)(v)Peak wattage, Im, Vm and fill factor of the module(vi) Date of year of obtaining IEC PV module qualification certificate including the test lab issuing IEC certificate.(vii)Unique serial no and model no of module(viii)IV curve of module(f)The temperature coefficient of power for the module shall not be more than 0.50% per degree Celcius.(g) Every module must have bypass diode of suitable capacity.(h) PV module must confirm to latest edition of IEC 61215/ IS 14286. In addition the modules must confirm to IEC 61730 Part I and II for construction and testing & safety qualifications and confirming to IEC 62804 PID.(j) It shall also be in confirmity to latest minimum technical specification issued by MNRE & IREDA from time to time. Modulesshould be of MNRE & IREDA approved companies and as per latest IEC/IS standards.(k)Provision of earthingand earth strip / cable etc for earth of solar PV module/ array etc as per latest IS/MNRE & IREDA norms to be provided and cost of the same is deemed to be included in the item and no extra amount will be paid to the contractor on this account. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474). 18 Sl Item 2 Contd….(l)RFID reader is to be provided by contractor(m)Both PV cells and SPV modules shall be make in India.(n) The minimum Net Annual Generation shall be 1,460 units per Kilo Watts. 19 (B)Junction Boxes : Supply and fix jucntion boxes of suitable Nos (as per design)/ OEM recommendations inputs and suitably rated output having separate DC fuses for both (+) & (-) on input and isolator on output terminal for each string. Each junction box must have a spare input terminal. The junction boxes shall be dust and vermin proof and water proof made of FRP/ Thermo Plast with IP 65 protection in compliance with IEC 62208 and shall be UV resistant, fire retardant. It shall have surge protection and maintenance free earthing as per relecant standard. The junction box shall have suitable arrangement of the following :-(a)The strings are required to be connected to the copper bus bar through individual fuses.(b) Provide arrangement for disconnection (DC dis-connection switch) for each SJB/ SCB.(c)Provide a test point for each sub group for quick fault location and to provide group array isolation.(d)Each array box shall be of relevant IEC standard.(e) Each array junction box shall have suitable bypass & reverse blocking diodes for maximum DC blocking voltage of 1000V with suitable arrangement of its connection. Reverse blocking and bypass diodes shall work for extreme temperaturesand shall have efficiency of 99.98% confirmed by appropriate IEC standard.Make : As per OEM 20 Sl Item 1 Contd…(C)DC Cables : Suitable size of XLPE insulated tinned Copper cable (min 6 sqmm of size) of Solar grade, 1100 Volts and UV resistant for outdoor installations confirming to IEC : 60227/15694 & 60502/ IS : 1554 (Pt I&II) and shall be as under :-(a) All cables and connectors for use of installation shall be of Solar grade which can withstand harsh enviromnetal conditions including high temperature, UV radiations, rain, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/ IS.(b) All the cables / wires shall be provided with UV resistant printed ferrules for DC side.(c) The size of the cable shall be such that avearage voltage drop at full power from PV module to inverter shall be less than 1.5%.(d)Cable batch No, drum No, IS code and size and make shall be metioned on every one meter or as per OEM practice.(e) The wiring of the module interconnection shall be in UPVC/HDPE pipe of suitable size. (f) The cost of interconnecting DC Copper cable, MS cable trays, and earth work for trenches/ MS cable trays suitable to accommodate Solar grade cables from SPV module upto inverters are included in the item. 21 Sl Item 1 Contd….(D)Module Mounting Structure (MMS) : Design, procure, fixing, support structure made of hot dipped galvanised with min 85 micron thickness including necessary welding and associated work (cutting, grouting, PCC filling, dispoing waste material, etc., complete) and fixing mounting arrangement suitable for SPV modules so as it can withstand wind speed of 200 km per hour. The mounting structure is to be installed at MS car parking structure and the array structure has to be so designed that maximum load is directly on main supporting structure of car parking coumns. It shall also occupy minimum space without sacrificing the output of SPV panels & adequate space between the arrays shall be available for easy cleaning and maintenance. Nuts, bolts, mounting structure including module mounting structure shall have to be adequately protected from the atmosphere and weather prevailing in the area. All the fastners shall be of Stainless Steel of grade SS316. Notes : (a) Two numbers of anti theft fastners of Stainless Steel on two diagonally opposite corners of each module shall be provided. (b) The modue mounting structure shall be of fixed to provide maximum generation. (c) MMS design shall be supported with Stadpro Report vetted by Third Party (Gov Institute) and submitted for the approval of the Acepting Officer. (d) The height of Roof top MMS shall be as per latest MNRE & IREDA guidelines. 22 Sl Item 2 Contd….(E) Lightning Protection for PV Array : Design, procure and fix lighting arrestor system cofirming to IS/ IEC-62305 (Part 1 - 4) on the car parking roofs. The air terminalshall be fixed at the top of GI elevation pole with base so as to be at least two meter above the structure to be protected. Its height above roof level shall be depend upon the level of protection and protection radii required. Notes : (a) The cost of all equipments, Copper strip upto earth test point, etc., shall be deemed to be included in this item. (b)The cost of sufficient earthing for lightning protection is also included in this item and no extra payement will be made to the contractor on this account.(F) Power Conditioning Unit : Procure, fixing, testing and commissioning of 25 KW AC (nominal power), Solar power inverter suitable to convert DC power of Solar PV module/ array to AC for further feeding to grid confirming to IEC : 61683 for efficiency, IEC : 62109-1 or equivalent for safety and IEC : 62093 for reliability. The input DC & output AC technical specification of Inverter are as under :-.Input (DC)(a)Max Absolute DC input Voltage : 1000 Vb)Start-up DC input voltage : 360 - 500 V (Default 420V)c)Operating input DC voltage range : 300 - 950 V(d)No of independent MPPT : One(e)MPPT input DC voltage range at Pacr :480 - 800 V DC(f) Max input DC Current : 110 A(g)Maximum input short circuit current : 160 A(h)No of Protected DC inputs : 8-20 23 Sl Item 2 Contd….(G) Output AC(a)AC grid connection type :3Phase (4W + PE)(b)Nominal Power at unity PF : 25 kW(c)Max AC output power : 25 KW(d)Max AC output Apperant power : 25 KVA(e)Max AC output Current : 44 A(f) Max AC fault current : 1.25 to 2.5 times of rated current(g)Nominal Output Voltage : 415 V(h)Output voltage range : 415 V ± 20%(j) Output Frequency : 50 Hz± 3Hz(k)Power factor : > 0.995(l) Harmonic Distortion Current : < 3%(m) Efficiency : > 98%(n)Standby operation consumption : < 1.5 W 24 (p)Operating temperature upto 85 degree centigrade(q)The inverter shall have minimum IP-67 protection, ground fault monitoring, grid monitoring, protection for anti-islanding, DC reverse polarity, AC and DC short circuit current and over current, AC and DC over voltage and over temperature. (r) The inverter shall adjust voltage and frequency levels to suit the grid.(s)The inverter shall be self commulated with Pulse Width Modulation (PWM) technology and shall be capable of synchronise maximum with in one min.(t) Maximum Power Point Tracker (MPPT) confirming to IEC 62093 shall be integrated in the inverter to maximise the energy drawn from the PV array(u)Monolithic design of inverter is not permitted.(v)The inverter shall have suitble nos of protected inputs (asper design) and outgoing shall be protected by ACB/MCCB. 25 Sl Item 2 Contd….(x)The inverter should have MODBUS, PROFIBUS, ETHERNET common ports.(y) The inverter shall include appropriate self protection and self diagnostic feature to protect itself and the PV array from the damage in the event of inverter componant failure or from parameters beyond the inverters safe operating due to internal and/ or external causes. Inverter shall have protection arrangement against ground leakage faults, over voltage, (SPD) & over current. Inverter shall have arrangement for adjustment for adjusting DC input current and shall trip against sustainable fault down stream and shall not restart till fault is rectified.(z)The inverter should have provisions of Galvanic isolation, anti-islanding protection (IEEE 1547/UL 1741) equivant IS and lightening.(aa) PCU must have the feature to work in tandem with other similar PCUs and be able to be successively switched ON and OFF automatically based on solar radiation variations during the day. 26 Sl Item 2 Contd…. (H) Balance of System (BOS) Items/ Components :- The BOS items/components of the SPV power plants/ systems deployed under this project shall conform to the latest edition with certificate of IEC or equivalent BIS Standards/ MNRE specifications/ as specified in Para 1.01 of Minimal Technical Requirements/ Standards for SPV System/ Plants to be deployed during this financial year under the programmes of MNRE available on MNRE website as on last date of quoting of tender.Notes : (a)The contractor must visit the site before quoting the rates for this item to asses the site condition so as to decide up on location and layout of SPV, placement of inverter, length of DC cables, lightning arresters, etc., complete.(b) The contractor shall submit complete scheme including electrical diagram of the work, schematic diagram, SPV module layout, placement of LAs, Civil work,etc., complete as per IREDA latest guidelines as applicable, Relevant IEC/IS norms to the GE for approval with in one month of date of commencement of the work. 27 Sl Item 2 Contd…. (c) The rate quoted is deemed to be inclusive of the all protection system including surge, lightning arresters and necessary earthing all as specified and directedd) Quoted rates inclusive of necessary faciility for monitoring of solar power generation through app along with necessary sim card and recharge for 2 years(e)Training : On successful commissioning of the plant, training shall be provided on plant operation and maintenance to a team (Engineers and technicians/ operators) as nominated by department for minimum one month. 28 (J) Operation and Maintenance for preventive maintenanceof 25 kwp plants (Demo ii coy & 5 DSC pln) Roof top solar plant for a period Year of 3 years after 2 year Defect liability periodfrom project completion date:The scope include:i. Cleaning once in a month. (ii). CompetentpersonsthroughAuthorizedServicecentrewillalwaysbe deputed to respond the calls who are aware of safety and statutory norms.(iii). For monthlycleaningand preventivemaintenanceactivity (one expert engineer and two semi-skilled technicians will be deputed and they will submit monthly report.(iv). sensors & Data Logger once in 2 month a.Sensor healthinessb. Optical Fibre Communication loop healthinessc. Data logging accuracyd. Frequency- Monthlyv. Reliability Centred Maintenance once in a montha.Preventivemaintenance ofthecompleteplant-Stringhealthiness, presenceof burnmarksorlocalhotspots,Inverterchecking, checkingof healthiness of power distribution panels etc.b. Integrity improvement (proper identification of strings and all cables)c. Frequency-Monthlyvi. Breakdown Callsa.Toberespondedwithintwohrsandresolutionwithin24to48hrsfor minor issues like string problem etc. on a working day.b. Call log notification time will start from the time a mail has been triggered by the Solar Log system or Customer reports any abnormality c. Visits of any OEM Engineer will be organized vendor/contractor wherever specialized input is required for addressing the breakdowns at site (without any extra cost).vii. Rate to be included for( 02+03) years Operation andMaintenance.viii.Retain 5% of amount quoted against this item till Total 02+03=05 yearsafter completion of date .However this amount could be released after submission of FDR/BGB in favour of concerned GE.Note:- For items : Solar cell and Solar Panel shall be Make In India.- The output specified will be AC output of Solar Power Plant.-The system/ RMU/ Busbar will be compatible with infrastructure of State Electricity Board.-MNRE/NSRE approved vendor will vet the design, supervise execution and will commission Solar Plant Work and will also certify the design output (agreement between authorised vendor and contractor to be submitted).-Necessary compatibility certificate of healthiness of Solar Power Plant infrastructure with State Electricity Board infrastracture shall be submitted by representative of State Electricity Board through the contractors.- During defect liability period one expert engineer and two semi skilled techicians will also monthly visit to provide service and shall submit monthly report to Engineer-in-charge.- The Contractor isrequiredto quotedthierRatefor Operation and Maintenance of Total 02+03=05 years andNo extraamount shall be paid on this acount. 29 Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size95 Sqmm x 3.5 Core. 30 Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size70 Sqmm x 3.5 Core. 31 M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type ofsoil/strata and testing on completion. Note:- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. 32 Supply and fix microprocessor based three phase electronic temper proof solar net meter CT operated, energy meter for net metering LT supply and grid solar with communication port, accuracy class 0.5, 3 phase, 240 Volts 100/5 A confirming to IS:13779. 33 Supply, fixing & laying GI tubing medium grade with one socket both end threaded in any length including cutting threading connection in new or old position and all type of GI new fittingsfor laid in trenches/ wall/ceiling/ floor/ all as specified and directed of25 mm bore GI pipe size 34 Supply, fixing & laying GI tubing medium grade with one socket both end threaded in any length including cutting threading connection in new or old position and all type of GI new fittingsfor laid in trenches/ wall/ceiling/ floor/ all as specified and directed of 20 mm bore GI pipe size 35 S & F Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixedingfor 20mm bore size 36 S & F Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixedingfor 25 mm bore size 37 M&L for Rotational polyethylene water storage tank of capcacity 1000 Ltrs (cylindrical vertical top) hoisted and fixed on round base of PCC1:2:4 in position all as specified 38 Supply installation of ball brass valve high pressure with polyethen float and planet complete screwed for for GI pipe 20 MM . 39 Supply install testing and commissioning offix pressure pump up to 1 H.P 40 Supply and fix installation testingPVC hose pipe type-1, 25 mm dia, 30 mtr long for cleaning of panels with spray Jet . 41 M&L for tapping/ cutting from GI/DI pipe any diameter including suitable size tee/fitting for 25 mm dia GI pipe complete all as specified. 42 M & L for sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etcone run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit. 43 S & F sheet metal enclosure MCB DB SPN 2 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. 44 S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, C curve complete all as specified and as directed. 45 M&L for mild steel framed work such as grills,gratingsetc with endsof bars shoulderedand or riveted,or forged into spikes,framed guard bars,barred iron doors ,ladders,walkwaysand similarworks conforming to fe290,gde E-165 ( iron ladder for 3 buildings) 46 Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth and getting out soft /loose soil complete all as specified and as directed for laying of under ground cable/pipe etc. complete all as specified and as directed 47 Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc 25 cm thick in soft/loose soil,complete,all as specified and directed. 48 Removing surplus excavated material to a distance not exc 50 meter and depositing where directed at level not exc 1.5m above the starting point,complete,all as specified and directed. 49 Material and labour for providing sand cushioning with dry fine sand including filling, spreading, levelling in layers in cable trench with approved quality of sand for protection of under ground cable complete all as specified and directed. 50 Supplying & laying burnt clay bricks, sub class B, designation 75,old size laid in trenches over cable protection complete all as specified and directed. 51 S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998
Contract Date: Nov 15, 2025 Contract Value : 69.97 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 7
48.
Educational and Research Institute #8246821 AOC
Bids Are Invited For Arduino Nano With Usb , Arduino Mega With Usb Case , Soidereiss 400 Pin Breadboard , Soil Moisture Sensor , Solf Adhesive Prato Shield , General Purpose Board Small , General Purpose Board Big , Female Berg Strip 40 Pins , Male Berg Strip 40 Pins , 16X2 Lcd Display , Usb Cables A To B 12 Inches , Usb Cables Mini 12 Inches , Battery Hw 9V 12V Rechargeable , 9V Battery Chargers , Resistor Box , Capacitor Box , Linear Voltage Regulator 7806 , Linear Voltage Regulator 7812 , Linear Voltage Regulator 7809 , Water Pump Module , Piezoelectric Plate , 8X8 Led Matrix Module , Bluetooth , Segment Led Display 4 Digit , Gsm 900 , Gps Neo 6M , Laser Diodes , Ldr Module , Keypad , Joy Stick , Active Buzzer Small , Active Buzzer Big , Motor Driver L293d , Sound Playback Module , Bo Motor , Bo Wheel , Node Mcu , Wemos D1 R2 , Vibrating Motor , Alligator Connectors 12 Inches , Battery Clips With Dc Jack , Hookup Wires Red Wire 100 Mtr , Hookup Wires Black Wire 100 Mtr , Jumper Cable Male Male , Jumper Cable Male Female , Jumper Cable Female Female , Rgb Leds , Leds Red , Leds Green , Leds Blue , Leds Yellow , Leds White , Diode 3 Types 25 Each Transistor Kit 3 Types 10 Each , Humidity Sensor , Touch Sensor Capacitive Touch Module , Metal Touch Sensor Module , Rain Drop Sensor , Flex Sensor , Temperature Sensor , Temperature Humidity Sensor , Force Pressure Sensor , Color Recognition Sensor , Water Flow Sensor , Sound Sensor , Ir Sensors Array For Line Following , 10000 Mah 5V Power Bank , Dc Motor 12V 150 Rpm , Position Servo Angle Based Metal Gear , Small Servo Metal Gear , Continuous Metal Gear Servo 360 , Small Servo Plastic Gear , 150 Rpm Bo Motor , L298p Motor Driver , Servo Motor Tester , 4 Wheel Robotics Diy Kit , Mechanical Construction Kit , Drone Kit , Aerospace Kit , Automobile Kit , Biomedical Kit , Agritech Kit , Bio Tech Kit , Water Sanitation Kit , Other Potential Stem Application Kit , 3D Printer Kit And Tools , Power Backer , Filament For 3D Printer , Drill Machine Set Wired , Workstation For Drilling , Nuts And Bolts And Screw M4x12mm , Nuts And Bolts And Screw M4x20mm , Nuts And Bolts And Screw M5x16mm , Nuts And Bolts And Screw M5x25mm , Nuts And Bolts And Screw M6x20mm , Cable Tie Small 100 Each 100Mm , Cable Tie Medium 100 Each 100Mm , Cable Tie Big 100 Each 100Mm , Sand Paper Grit 80 , Sand Paper Grit 100 , Sand Paper Grit 120 , Sand Paper Grit 200 , Sand Paper Grit 300 , Power Strip Adaptors , Welding Set , Tool Kit , Battery 11 Volt Rechargeable , Uv Sensor , Hacksaw , Extra Hacksaw Blade , Hacksaw Mini Blades , Hot Glue Gun , Pliers , Cardboard , Thermocol , String , Rubber Band , Solar Panels , Cell Holder , Switch On Off , Transistor 2N2220 Total Quantity : 2570
Contract Date: Ref. Documents Contract Value : 3.88 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 5
Jammu And Kashmir View Result →
49.
Housing Urban and Rular Development #8236170 AOC
Hopscotch Installation Of Hopscotch Floor Projection At Porunai Museum, Tirunelveli District. , Design, Development, Supply, Installation, Testing And Commissioning Of Interactive Floor Projection Installation-Hopscotch For The Department Of Archaeology, Government Of Tamil Nadu, Porunai Museum, Tirunelveli The Scope Of The Project In The Complete Conceptualization, Design, Development And Deployment Of An Interactive Floor Projection Installation - Hopscotch. The Objective Of The Project Is To Offer Children And Families An Opportunity To Engage In Culturally Rooted Play Within The Museum Premises, Transforming A Timeless Traditional Game Into A Vibrant, Digital Experience. The Proposed Hopscotch Experience Is A Digital Reinterpretation Of The Age-Old Indian Game, Designed For Physical Interaction Through Motion Sensing And High-Resolution Floor Projection. Visitors Will Be Able To Play On A Projected Hopscotch Grid Where Their Movements Are Tracked In Real-Time By Motion Sensors Installed On The Ceiling. As Players Hop On The Projected Spaces, Their Interactions Will Trigger Corresponding Visual And Audio Feedback, Creating An Immersive And Joyful Engagement That Is Both Fun And Culturally Enriching. This Initiative Aims Not Only To Entertain, But Also To Subtly Educate Younger Audiences About The Importance Of Cultural Games In Indian Tradition. , The Scope Includes The Development Of The Software Application With Multiplayer Functionality And Culturally Inspired Game Visuals. This Will Be Followed By The Procurement And Installation Of The Necessary Hardware, Which Includes A High Lumen 4K Floor Projector For Crisp And Bright Projection Motion Tracking Sensors For Detecting Player Movement. A High Performance Control Pc To Manage Sensor Data And Render The Visuals And Safety Equipment Such As Ceiling Mounts And Protective Casings To Ensure The Secure And Durable Setup. , High-Lumen Floor Projector Projection Technology: Rgb Liquid Crystal Shutter Projection System (3Lcd) Projection Type: Ultra-Short Throw / Short Throw Ceiling-Mounted Projection Lcd Resolution: Full Hd (1920×1200) Native, With 4K Enhancement Support Brightness: Minimum 6000 Lumens Projection Lens Type: Optical Zoom (Manual) / Focus (Manual) F-Number: 1.51 – 1.77 Focal Length: 18.2 – 29.1 Mm Zoom Ratio: 1.0 – 1.62 (Optical Zoom) Throw Ratio: 1.32 – 2.12 Light Source Type: Laser Diode Light Source Life: Minimum Of 20,000 Hours And Above Zoom (Wide): 31? To 310? Screen (88 – 906 Cm) White Light Output (Normal / Extended): 4600 Lm / 3200 Lm Color Light Output (Normal): 4600 Lm Contrast Ratio: Over 50,00,000:1 Sound Output: 16 W Monaural Vertical / Horizontal Keystone: ± 30° / ± 30° Analog Rgb Input D-Sub 15Pin: 2 Digital Input Hdmi: 2 (Hdcp 2.3) Audio Output Stereo Mini Jack: 1 Network Wired Lan: Rj45 × 1 (100 Mbps) Wireless: Built-In Power Supply Voltage: 100 – 240 V Ac ± 10%, 50/60 Hz , Direct Power On / Off: Yes Air Filter Type: Electrostatic Filter Fan Noise (Normal / Quiet): 37 Db / 27 Db 1 Year Warranty , Motion Tracking Sensors Measurement Characteristics Detection Range @ 90% Reflectivity: 20 M Detection Range @ 10% Reflectivity: 8 M Statistical Error: ±30 Mm Aperture Angle: 270° Point Cloud Data: Configurable At 1 / 2 / 4 / 8 Spots Scanning Frequency: 10–30 Hz Angular Resolution: 0.08° Electrical Characteristics Supply Voltage: Dc 12 V – 24 V Working Current: 0.21 A @ 12 V (Typical) Power Consumption: 2 W Laser Class: 905 Nm, Class I (Eye-Safe) Data Transmission Interface: Ethernet 100Base-Tx Operational Features Startup Time: <10 Seconds Indicator Lights: Power Indicator And Status Indicator Ambient Light Resistance: >50,000 Lux Operating Temperature 10 C ~75 C Storage Temperature30 C ~ 75 C Humidity<80% Working Life 5 Years (Motor Life) Enclosure Ratingip67 Dimentions (Lxwxh) 50X50x76 Mm Weight 148 G (Without Connecting Cables ) 1 Year Warranty , Ceiling Mounts + Casing Custom Mounts For Projector & Sensors, Tamper-Proof, Powder-Coated Metal Casing, Cable Concealment (Aligned With The Museums Architecture) , Software & Content, Integration & Testing, Training And Support 1 Year Multiplayer Interactive Hopscotch Game, Built On Unity/Unreal Engine, Cultural Themes, Sound & Animations Hardware-Software Integration, Motion Calibration, On-Site Testing, Optimization Dry Run, And Staff Briefing , Pc Type: Nuc Processor: Intel Core™ I7-8559U (2.7 Ghz – 4.5 Ghz, Quad Core, 8 Mb Cache, 28 W Tdp) Operating System: Windows 11 Cpu Model: Intel Core I7 (12Th/13Th Gen, 12 Cores+) Graphics: Iris Plus Graphics 655 Hdmi 2.0A (4K @ 60 Hz) Usb-C With Displayport 1.2 Lan Inputs: 1 × Intel Gigabit Lan Thunderbolt: 3 × Thunderbolt 3 Ports (Up To 40 Gbps) Usb: 4 × Usb 3.1 Ports (2 Rear, 2 Front Including One Charging Port) Bluetooth: Dual-Mode Bluetooth 5.0 Memory Storage Capacity: 500 Gb Ram: 16 Gb Motherboard: Intel Nuc8i7beh Motherboard Hardware Controls: Processor Fan Speed Control Voltage And Temperature Sensing Fan Sensor Inputs For Monitoring Acpi-Compliant Power Management Control Audio: 5.1 Surround Via Hdmi Headphone/Microphone Jack (Front Panel) Dual-Array Microphones (Front Panel) Power Backup (30 Minutes) Numeric Digital 1000 Plus V Ups 1000Va .1 Year Warranty => Limited
Contract Date: Sep 29, 2025 Contract Value : 13.98 Lakh
Government Departments No of Bidders 3
Contract Date: Ref. Documents Contract Value : 53.39 Lakh
Government Departments No of Bidders 3
West Bengal View Result →
TenderDetail
Loading tenders