View Bid Results For Digital Cross Connect Tenders

We found 199 Bid Results related to digital cross connect tenders. You can find Contractor details who won digital cross connect tenders along with contract details in Bid awards announcements section.

Filters
Stage
146
31
22
Tender Publishing Platform
24
175
State / UT
28
48
23
15
13
13
12
11
8
8
6
4
4
4
4
3
3
3
3
2
2
2
2
1
1
1
1
1
1
Contract Value
56
26
76
41
Publish Date
1
0
0
0
0
Sector
18
62
48
30
17
10
5
5
4
4
3
3
2
1
1
1
1
1
1
Ownership
6
106
64
14
13
1
1
Within keyword
Active filters:
Showing 1–4 of 199 tenders matching your filters
2.
Defence #11281747 Technical Bid
Tender For Provision Of Defi Md Accommodation At Kota Mil Stn; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 2 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 3 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 4 Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND HARD STANDINGas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 5 Lump sum price worked out by the contractor for SEWAGE DISPOSALas listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 6 Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 7 Lump sum price worked out by the contractor for FENCINGas listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 8 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 9 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 10 Lump sum price worked out by the contractor for LIGHTING PROTECTION as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 11 Lump sum price worked out by the contractor for FIRE FIGHTINGas listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 12 Lump sum price worked out by the contractor for LIFT WORKas listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 13 Lump sum price worked out by the contractor for HOT WATER SUPPLYas listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 14 Lump sum price worked out by the contractor for DG SETSas listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 15 Lump sum price worked out by the contractor for SITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORKas listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 16 Sch A Part-XVI MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes:(i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XVSITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORK schedule). 17 INTERNAL WATER SUPPLYS&F for 15mm dia sink mixer (wall mounted) with 150mm long swivel spout,connecting legs and wall flangerswith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2014511 / Hindware Cat Part No F690058 / Parryware Cat Part No G3335A1 or equivalent make as mentioned in Appx B. 18 S&F for 15mm dia single lever center hole basin mixerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F1015451 / Hindware Cat Part No F690012 / Parryware Cat Part No G4863A1 or equivalent make as mentioned in Appx B. 19 S&F for 15mm dia wall mixture with bend pipe for overhead showerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2002401 / Hindware Cat Part No F330020 / Parryware Cat Part No G3316A1 or equivalent make as mentioned in Appx B. 20 INTERNAL ELECTRIFICATIONS&F ofmodular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005as specified in IS 732: 2019 etc complete all as specified and directed 21 S&F for modular type 1 module RJ-11 telephone socket with shutter etc complete all as specified and directed 22 S&F for modular type 1 module co-axial type TV socket etc complete all as specified and directed 23 S & F for 16 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 24 S & F for 25 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 25 S & F for 32 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 26 S & F for 40 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 27 S&F forSingle Phase Dual Source Pre Paid Meter, Class 1.0, RS485,10/60A Direct,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 28 S&F forThree Phase Dual Source Pre Paid Meter, Class 1.0, RS485, 5A CT operated,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 29 S&F of Sheet metal enclosure distribution board VTPN4 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 30 S&F of Sheet metal enclosure distribution board VTPN6 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 31 S&F of 160A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply etc complete all as specified and directed by engineer-in-charge. 32 S&F for 12W LED Downlight having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed . 33 S&F for LED light fitting with high 10 watt 220 V AC decorative wall type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size etc complete all as specified and directed . 34 S&F for 10W LED bulk head light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed. 35 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 600 mm sweep. Min air delivery 115 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) etc complete all as specified and directed by engineer-in-charge. 36 Supply and fix Wall Mounting Fan, steel body AC single Phase, 230V,With Sweep Size, 200mm ; Motor Speed 84CMM, 3 blades, and frame and louvers etc complete all as specified and directed by engineer-in-charge. 37 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type BUILDING PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge.The BUILDING PANEL shall comprise of the following:(A) Bus bar Chamber(i) 01 Set (3L + N) of copper busbar of rated capacity 400A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connections. 38 (B) Incoming:- (i)320A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 No.(ii) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 No.(iii) LED phase indicators (Red, Yellow, Blue)- 01 Set 39 (C) Outgoing:-(i)40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, havingtrip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 08 Nos(ii) LED phase indicators (Red, Yellow, Blue)- 08 Sets 40 SEWAGE DISPOSALS&F for DWCPE (SN8) 180mm outer dia and 163 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8)with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 41 S&F for DWCPE (SN8) 200mm outer dia and 175 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 42 S&F for DWCPE (SN8) 300mm outer dia and 260 inner dia of pipe for depth 1.65mm to 2.3m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 43 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-7 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 44 S&F forNonclog submersible (sewage disposal), pump set, electric driven 415 Volts 3 Phase 50 Hz, supply comprising of pump with cast iron impellors, submersible motor of suitable capacity, coupling, at discharge 3360 to 480 LPM and minimum discharge should be less than 480 LPM at minimum head 14 m.including chain pully block of two MT capacity 01 Noandsuitable arrangement for hanging the motor through chain of requirement of delivery of pump connected to main pipe line by suitabe HDPE pipe of size 150mm Dia for required length with necessary connection etc all as specified and as directed. 45 Supply,installing, testingand commissioningout door type LT feeder piller box of suitable size 750X750X450 mm, pedestal mounted, CPRI type test totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and paintedto both internal and External surfaces with powder coating paint in heatprocess of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and includingfollowing accessories and mounted on PCC Platform made out of100 mm thick PCC (1:3:6),0.45 Mtr all round the panel board etc complete with the following items :- 46 Incoming:- (i) Copper bus bar made up of copper strip100 amps duly mounted on bakelite insulatorssleevings of standard colour code - 01 Set. (04 No strips for Phases & Neutral)(ii) MCCB TPN 415 Volts,63 Amps, 50 Hz, breaking capacity 25 KA with fixed thermal & magnetic setting ( For Incomming ) - 01 No.Outgoing:-(i) MCB TP 415 volts 32 Amps, breaking capacity 16 KA with fixed thermal & magnetic setting ( For FPB2 ) - 03 Nos(2 nos for pump 1 nos for spare). (ii) FASD Starter for 15 HP Motor with single phase preventer, OLP and dry run protector- 02 Nos 47 (iii) Analogue type modular volt meterof range 0-500 volts -01 No(iv)Volt meter selector switch-01 No.(v) Analogue typeAmmeter of range 0-200 Amp-01 No(vi) Ammeter selector switch-01 No(set of three)(vii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (Red, Orange, Blue) - 01 set(viii) CT 200/5 Amps - 3 Nos 48 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 49 S&F forPVC insulated and sheathed 1100 volts grade flat type submersible 06 sqmm cable three core multi stranded conductor etc complete all as specified and directed . 50 M&L for Making drill hole by trenchless technologyof suitable size under road for laying pipe line of size150mm bore at 1 metre depth from the road level etc complete all as specified and directed.Note :- Drill hole (trenchless) shall be done without disturbing top surfaces of road by appropriate machine. 51 M&L for steel gate 5.45 m wide and 2.70 m height with RCC pillar including excavation in any type of soil, plastering, painting, etc complete all as specified and shown in TD/2008/101 sheet No 1/3 to 3/3 52 EXTERNAL WATER SUPPLY Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 100mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 53 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-9 IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 54 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 55 Supply and fix CI foot valve with leather washer, ofsize 100 mm , lift and swing, single door, IS 4038 marked one with each pump suction line complete all as specified and directed. 56 M&L for construction of valve chamber of brick masonry from the top of surface with MS covers 3.15 mm thick and 40x40x6 mm MS angle with hinges for locking arrangement including excavation and earth works PCC (1:3:6) type C2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1, plastering in CM 1:3 painting with two coats of synthetic enamel paint over a coat of red oxide primerfor the size of chamber 1200 mm x 1200 mm x 1200 mm (internal dimention) complete all as specified and directed. 57 Supply, install,commissioning and testing of Horizontal split case cetrifugal pump set 1450 RPM having an output of minimum 1100 LPM at a head of 45 mtr coupled to 3 phase 415 volt squirel case induction motor of adequate capacity complete all as ditected by Engr-in-charge with and including following :-(a) Necessary cable for interconnection between starter panel & pump set with 1100 volt rated copperinsulated unarmoured cable of minium 10 sqmm 3 core cable(b) Single phase preventer (current sensing type)(c) Necessary light grade GI pipe protection for cabling from pump set to LT panel.(d) Bourden pressure gauge.(e) MS pipe flanged type class B of size 100 mm bore upto foot valve from suction end of pump.(f) PCC foundation in type B-2, 1:2:4 using 20mm graded aggregate, 20cm above ground level and 30cm below grond level including grouting of eye bolts nut etc. for pump set of adequate size or as per manufacturers recommendations.Note: All other items/material requiredfor fixing pumpset shall be included in cost quoted.(ii) Foundation drawing shall be approved by GE/ Eng-In- Charge before fixing the pump set. 58 Supply, installations, testing and commissioning of factory made LT Indoor cubical typepanel boardhaving 150 Amp rated copper bus bar with neoprene rubber gasket and locking arrangement, dust,weather and verminproof , free standing, floor mounting type self ventilation with wire mesh,totally enclosed busbar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2mm thick CRCA sheet duly painted with seven tank process,415 V,TPN,50Hz both side properly welded MS angular supported with chanel frame of size 50mm,at all vertical corner grouted in PCC 1:3:6 (Type-C1 using 20mm graded stone aggregate) and connecting the incomming/outgoing feeder by providing brass cable glands and Lugs complete all as specified and directed comprising of followings accessories:- 59 Incoming:- (i) MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal Setting-01 No.Outgoing:-(i)MCCB 3 Pole 63 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with adjustable thermal Setting - 02 Nos (ii) Single phase preventor -02 Nos(iii) On load Change over switch 4 pole of current raring 63 A (open execution type) - 01 No(iv)MCB SPN 10 Amp C curve, 10 KA capacity - 01 No(v) fully automatic Star-delta starter 15 HP or recommended by manufacturer of motor -02 Nos(vi) LED Indicator lamp (R,Y,B)- Set of Three.(vii) Multifunctional meterDigital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. 60 M&L for construction of header of ERW pipe having size dia 300 mm and length 2.5 m with two inlet connection of size 100 mm & three otlet connection having size 150 mm complete monting on RCC base/plinth etc complete all as specified and as directed by Engr-in-charge. 61 EXTERNAL ELECTRIFICATIONBoring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 100mm dia complete all as specified and directed.Note :- GI pipe shall be measured and paid separately. 62 Taking out existing HT XLPE U/G cables, 11000 V grade from trenches/ducts/ poles etc of size 120 Sq. mm 3 Core etccomplete all as specified and directed. 63 Dismantling and taking down existing transformer mounted on four pole structure and shifting to nearest suitable location including its fixing on newly constructed platform and making all connection, testing as per requirementetccomplete all as specified and directed. 64 Dismantling and taking down existing 4-pole structure etccomplete all as specified and directed. 65 Dismantling and taking down existing 03 Nos of LT Panels, refixing at specified locationincluding connecting etc complete all specified and directed. 66 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 240 Sq. mm 3.5 Core etc complete all as specified and directed. 67 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 185 Sq. mm 3.5 Core etc complete all as specified and directed. 68 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size upto 95 Sq. mm 3.5 Core etc complete all as specified and directed.Note For item No. 57 to 63 :- The old material obtained from site shall be deposite by contractor in MES store yard without any extra cost as directed by GE. 69 M&L for construction of plateform of size 3500 x 3500 x 1200mm with brick construction in cement mortar 1:4 PCC (M-10 nominal mix) in foundation, 100mm thick RCC M-25 grade slab, with 8mm MS TMT bars 120mm c/c on bothway, brick masonary steps on one side XPM Jali fixed on angle iron 40x 40x6 mm post upto height of 8 feet above ground level and openable gate with locking arrangment including making provision for entry and exit of HT/LT cables and steps made to access to the top of plateform including plastering to bricks masonary complete including painting with 2 coats of whitewash on plastered surface and painting steel surface with 2 coats of red oxide primeretc complete all as specified and directed. 70 Supply & fix HT 11 KV, outdoor type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complee with drop out fuse having 12 insulators of rating upto 200 Amps etc complete all as specified and directed. 71 Supply and fixing lightning arrestor HT 11 KV, 10 KA station class etc complete all as specified and directed. 72 Supply & errect 2 pole structure on 11 mtr PCC pole consisting of pole with anti-climbing device, PCC foundation & cross arms (Bracings) etc for one incoming and one out going. etc complete all as specified and directed. 73 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station (CSS) ,315KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply .Package substation will have the following equipment :- 74 HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos 75 (vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 SetTRANSFORMER315 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 955W and Max Losses @ 100% Load 2750 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be conforming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 500 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)500 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB)(ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 76 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust. 77 construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 78 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station , (CSS) 400KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply.Package substation will have the following equipment :-HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the 79 RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos.(vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set 80 TRANSFORMER400 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 1150W and Max Losses @ 100% Load 3330 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 630 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)630 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB) (ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 81 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robustconstruction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 82 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge(Panel 1 - Near mains transformer GTC Area):- 83 INCOMING :-(i) S&F ACB 4 Pole 630 amps ,415 Volt electrical drawout type of breaking capacity not less than50 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 750 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBsOUTGOING:-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of block )(ii) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(ivDigital volt meter 0-400 V with selector switch - 01 No.(v)LED Indicating Lamps R,Y,B - 01 Set of three 84 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2 - Near Chambal Vihar Main Tfr Panel):-INCOMING :-(a) S&F MCCB 4 Pole 500 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(b) Aluminium electrolite Busbar 600 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 85 OUTGOING:-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of blocks)(ii) S&F MCCB 4 Pole 160 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Street light timer using Power contactor 32 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(iv)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(v)Digital volt meter 0-400 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 86 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1A - LT PANEL FOR 3 X BLOCKS GTC):-INCOMING :-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 87 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 04 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 88 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2A - LT PANEL FOR 2 X BLOCKS CHAMBAL VIHAR):-INCOMING :-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 89 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 03 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 90 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1B & 2B):-INCOMING :-(i) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range-01 No incoming.(ii) Aluminium Electrolite Busbar 300Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 91 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series. - 01 Nos (for PH Panel)(ii) MCCB 4 pole 40 Amp, 415 V, 16 KA, C-series- 02 Nos (sewage PH +spare).(iii) MCB TPN 25Amp, 230 V, 10 KA, C-series - 07 Nos (Lifts+fire fighting+Street lights)(iv)Street light timer using Power contactor 25 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(v) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(vi) Digital volt meter 0-500 V with selector switch - 01 No. (vii) On load Change over switch 4 pole of current raring 63-100 A (open execution type) - 01 No.(viii)LED Indicating Lamps R,Y,B - 01 Set of three 92 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel D - DOE Area):-INCOMING :-(i) S&F MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0)-01 No incoming.(ii) Aluminium Electrolite Busbar 150 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 93 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series - 02 Nos (for Bldg + Spare)(ii) MCB SPN 10 Amp, 415 V, 10 KA, C-series - 02 Nos (Garages + Spare).(iii) MCB SPN 10 Amp, 230 V, 10 KA, C-series - 02 Nos (Security light + Spare)(iv) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(v) Digital volt meter 0-500 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 94 M&L for factory made busbar box 750 Amps rated Aluminium busbar, 3 phase, 4 wire, 415 Volt of size not less than 300mm x 200mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wal by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 95 M&L for factory made busbar box 600 Amps rated Aluminium busbar, 1 phase, 245 Volt, size not less than 200mm x 150mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wall by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 96 Supply and fixing poly carbonatejunction box , weather and vermin proof of size 250X250X160 including provn of 4 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators ,including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, double washer and FI clamps ofsuitable sizefor taking connections and fixing on LT steel tubular poles complete with locking arrangementcomplete all as specified and directed. 97 Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 1.5Sqmm 1100 Volt , draw through LT steel tubular polesfor connection to street light from junction boxetc complete all as specified & directed. 98 S&F for Cable route indicator, duly engraved with LT CABLE 1100 VOLT on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of flat iron 40 x 5 mm, welded/riveted on back side of plate, fixed and grouted in position with PCC 1:3:6 type C-1, block of suitable size etc complete all as specified & directed. 99 M&L for Precast PCC (1:2:4) type B-1 cable path indicators of size 300x100x500mm rounded top having engraved in capital letters HT Cable embedded in position in PCC(1:3:6) Type C-1, using necessary formwork and including provision of two coats of cement base paint on exposed concrete surface and writing HT Cable in black synthetic enamel paint etc complete all as specified & directed. 100 M&L fordecorative LED post top lantern (PTL) luminior with die cast aluminium spigot, spun aluminium powder coated top cover clear/opal acralic difusser LED light fitting of 25 watts including LED lamp etc complete all as specified & directed. 101 M& L for shifting of 33 KV HT cable to a safe distance from proposed building, supply, laying, testing & commisioning of 33 KV cable in replacement with new as per estimate provided by State electricity deptetc etc complete all as specified & directed. 102 FIRE FIGHTINGS&F forAutomatic air release valve 50mm dia suitable for domestic water with 25mm gun metal stop valveetc complete all as specified & directed. 103 S&F forbranch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090etc complete all as specified and directed. 104 S&F forfix Valve, stop, screwed, 25 mmdia pipeetc complete all as specified and directed. 105 S&F for6 kg capacity Multipurpose dry chemical powder (ABC) type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged .etc complete all as specified and directed. 106 S&F forCO2 type fire extinguisher of 3 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683.Extinguisher shall be painted with red enamel apint and fixed to wall with bracket etc complete all as specified and directed. 107 S&F for9 Ltr capacity Foam type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/chargedetc complete all as specified and directed. 108 S&F fortesting of Star-Delta starter Panel for fire fighting pump motor etc complete all as specified and directed. 109 Supply, installation, testing & commissioning ofFIRE SIGNAGES for indication/information of fire exit, alarm panel, fire extinguishers fire axe, hose reel, hydrents, lifts of size 300mmx100mm etc complete all as specified and directed. 110 DG SETSSupply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 180 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 111 (A) Engine (prime mover) : Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. 112 (C) Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate.(D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1No 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications.(F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - 113 (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running (iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- 114 AC voltmeter - 01NoVoltmeter selector switch OFF/RY/YB/BR - 01NoFrequency meter - 01NoAC voltmeter of suitable scale - 01NoAmmeter selector switch OFF/R/Y/B - 01NoCurrent transformers of suitable ratio - 01NoBattery charger consisting of - 01No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01NoMains supply voltage monitor - 01NoSet of DC control relays and timers - 01NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01No 115 01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 116 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 117 Supply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 125 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 118 (A) Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. (C)Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate. 119 (D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1Nos 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications. 120 (F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running(iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- AC voltmeter -01 NoVoltmeter selector switch OFF/RY/YB/BR - 01 No 121 Frequency meter - 01 NoAC voltmeter of suitable scale - 01 NoAmmeter selector switch OFF/R/Y/B - 01 NoCurrent transformers of suitable ratio - 01 NoBattery charger consisting of - 01 No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01 NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01 NoMains supply voltage monitor - 01 NoSet of DC control relays and timers - 01 NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01 No01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections. 122 KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 123 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 124 Supply, installations, testing of electric chimney of size 60cm havingsuction capacity of 1200 cum per hour with filterless technology sealed motor and insulationfor oil deposit and water vapour alongwith self autoclean feature after 30 cycles of operation and minimum 5 year warranty etc etc complete all as specified and directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
3.
Housing Urban and Rular Development #11175999 Technical Bid
Tender For Additional Work In Adj No 2 Court Distt. Baran- 1 S&F Following Sizes Of Isi Marked ( Is:14927 P - Ii ) Virgin Material Upvc Trunking Along With Accessories Like Coupler, Inner, Outer, Elbow, Square Box, Tee, End Cap Etc. On Surface With Screws, Expansion Fasteners As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 2 25 Mm X 12 Mm 3 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 4 2 X 2.5 Sq. Mm. + 1X1.5Sqmm 5 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm. 6 Providing & Fixing Of Modular Type Lockable Feature Socket Duly Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 7 25 Amp. 2 Module Socket 8 Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (Is 11037:1984 ) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 9 5 Step Fan Regulator 2 Module 360 Dgree Rotating 10 Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 11 Led Skirting /Foot Light 2 Module 12 Modular Mcb 6 A To 32 A Sp 13 Providing & Fixing Of 1200 Mm Sweep Bldc Technology Power Saving Ceiling Fan Which Can Withstand On Votage Fluctuations From 140 Volts To 240 Volts ,Power Factor Not Less Then 0.9 , Service Value (Cmm/W) Minimun 6.85 , Air Delivery Minimun 220 Cmm, Speed Minimum 330 Rpm ( Tolerance As Per Is:374 2019 ) Thd Less Then 10% And Complete With Down Rod Of 15 Mm Dia . Erw (Electrical Resistance Welded ) Of 1.6Mm Nominal Thick Medium Duty Steel Pipe Up To 80 Cm , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 14 Without Remote 15 Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 16 1200 Mm Sweep Bee 1 Star Rated (Service Value >=4.0 To 17 Rewinding Of Single Phase Motor Of 1400 Rpm Including All Necessary Material And Of The Same Characteristics As Original With Required Size Of Super Enamelled Wire E Class Insulation Material And Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 18 0.25 H.P. To 0.50 H.P. 19 Rewinding Of Single Phase/3Phase Submersible Motor Including All Necessary Material And Of The Same Characteristics As Original With Required Size Of Super Enamelled Wire E Class Insulation Material And Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 20 0.5 H.P. To 1.0 H.P. 21 Sitc Of Contactor Oem Fabricated Dol/Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Cordinatiom Chart And Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection, Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps Etc. Suitable For Following Rating Motors Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 22 For Single Phase Submersible / Monoblock Pump 23 0.5 Hp To 1.5 Hp (Dol Starter) 24 For Three Phase Submersible / Mono Block Pump 25 Upto 3.0 Hp ( Dol Starter ) 26 P/Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 27 2.5 Sq.Mm 3 Core Flat / Round 28 Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have ItS Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 29 6.0 Sq. Mm 30 4 Core 31 50.0 Sq. Mm 32 3.5 Core 33 Add Extra For Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Direct In Ground Including Excavation Of Trench Of Size 75 Cm (Depth) X 35 Cm(Width) , With Procedure As Per Following Points:- (A) Make A River Sand Bed Of Height 125 Mm Along The Trench, (B) Lay The Cable In The Middle Of The Trench, (C) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable, (D) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thickness And 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr.), (E) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, (F)Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth 34 P / L Of Double Wall Corrugated Hdpe Pipe Confirming To Is : 16205 P-24, Stiffness Class 750 N, Externally Corrugated And Having Smooth Surface Inside With Hdpe Coupler, Elbow, Tee At Required Depth Below The Ground For Laying Cable Of Following Nominal Outer Dia. Mfr Test Report From Nabl Accrediated Is To Be Submitted.(Excavation Of Earth & Back Filling With Compaction Is To Be Paid Extra)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 35 50 Mm 36 90 Mm 37 Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 38 Single Pole Mcb (With B/C Curve Tripping Characteristics) 39 6 A To 32 A Rating 40 Four Pole Mcb (With B/C Curve Tripping Characteristics) 41 40 A Rating 42 Supply , Installation, Testing And Comissioning Of Inverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And 50 Hz , Single Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 43 1.5 Tr Iseer Not Less Then 3.8 44 Supplying And Drawing Flexible / Stranded Bare Copper Conductor, Pvc / Xlpe Insulated, Overall Aluminium Mylar Tape Shielded Atc Drain Wire And Outer Pvc Sheathed Industrial Instrumentation (Shielded)Cables Voltage Grade 300/500 V As Per Bs /En 50288-7 In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping / Cable Tray / Open Duct Making Connections, Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Cables. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 45 Un Armoured 46 4 Core X 2.5 Sq.Mm 47 Supply, Installation, Testing And Comissioning Of Interconnecting Copper Refrigerant Piping Of Dhe Grade C12200- Astm B68, B75, Chemical Composition Of Copper %- 99.0 Min And Phosphorus %- 0.015 To 0.040 . For Annealed Copper Tube :- Tensile Strength = 210 Mpa Wih Elongation % = 40 Min . Ink Mark Brand Printing On Hard Tubes Should Be Present. Duly Insulated With Tubular Elastomeric Nitrile Rubber Fm/Ul Approved With High Water Vapor Diffusion Resistance And Low Thermal Conductivity Should Be Certified Class O In Fire Propagation As Per Bs 476 Part 6 Including Chase Cutting Andfilling With Mortar, Slotted Channel Supports Mounted On 10 Mm Threaded Rod At Suitable Spacing The Exposed Piping Shall Be Wrapped With Glass Woven Cloth And Lag Coating For Vapour Barrier And Weather Protection. Joints Shall Be Covered With Nitrile Rubber Tape Of 3 Mm Thick Complete As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 48 12.7 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation – 13 Mm Thick) 49 6.4 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation – 13 Mm Thick) 50 Providing & Fixing Of Is : 4985 - 2000 Class -4 (10 Kgf / Sqcm) Upvc Drain Water Piping With Fittings (Is:7834 & 10Kgf/Sqcm) Like Elbow, Socket, Tee, Solvent Cement Jointing, Support With Ms Hanger On Ceiling Or Recessed In Wall With Chasing & Plastering With 6 Mm Thick Closed Cell Elastomeric Nitrile Rubber Insulation Including Leakage Testing Etc. As Required Of Following Nominal Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 51 20 Mm 52 Making Hole In Stone Masonary/ Rcc Wall/ Rcc Slab With Core Cutter For Accomodating Refrigerant Pipe/ Drain Pipe/ Ms Pipe/ Cables Etc Of Following Dia 53 100 Mm Dia Per Running Inch Length 54 Supply & Fixing Ms Powder Coated Stand Suitable For 1.0/1.5/ 2.0 Tr Outdoor Type Of Split Ac. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 55 Supply, Fixing And Testing Of Following Capacity Iso Certified Company Made Wall Mounted Stabilizer Having Output Voltage Variation From 200 V To 250 V(+/-5%) With Input Voltage Variation From 170 V To 260 V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270 V With Providing Of 16 Amp /20 Amp Industrial Plug Top Making Connection Etc Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 56 3 Kva 57 Providing And Fixing Of Ip 65 Protected Polycarbonate / Polysterene Fuse Box Moulded With Inside Knock Outs Of Following Size With Hinged Cover, Transparent Window, Pu Gasket, Locking Arrangement, Duly Holded With 2 Nos. Pole Clamps Of 20 Mm X 3 Mm Flat With Nut And Bolts, The Box Shall Be Provided With Din Rail, 4 / 8 Way 10.0 / 16.0 Sq.Mm Heavy Duty Connector, Earth Terminal, Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 58 125 Mm X 200 Mm X 122 Mm 59 Supply, Drawing And Testing Of 4 Pair, 23 Awg Solid Bare Copper Wire Insulated With Pvc, Utp (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable As Per Latest Ammendments Of Ansi/Tia/Eia-568 , The Copper Conductors Should Be Balanced Twisted In Pairs, Seperated By A Cross-Member Fluted Pair Divider & Protected By Pvc Jacket. Certified Performance In A 4-Connector Configuration Upto 100 Mtrs Channel Requirements & Transmission Frequencies Up To 250 Mhz. In Existing Ms/Pvc Conduits/Casing Capping Including Making Connections To Information Outlets And Patch Panels With Jack & Ferruling At Both Ends For Identification With Necessary Tools For Punching, Stripping, Crimping And Testing Etc As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 60 Supply And Installation Of Unsheilded/360 Degree Sheilded Information Outlets Made Of High Impact Plastic Body With Abs, Fr Grade Halogen Free Material With Provision For Protection Against Dust In Jack, Suitable For Cat 6/6A Application Complying To Latest Ammendments, According. To Cat. 6/6A Channel, It Should Support Channel As Well As Components Requirements Of Cat.6/6A Standards At Frequencies Of Up To 250 To 500 Mhz. Cat 6/6A Unshielded/Shielded Jack Should Be Suitable To Terminate 4 Pair, 23/24 Awg Solid/Stranded Wire Diameters, Using 100 Ohm Unshielded/Shielded Balance Twisted Pair Cable, The Jack Should Have Tooless/Impact Termination On Reliable Copper Tin Plated Insulation Displacement Contact, With Easy Lock Mechanism, It Supports Iec 60603-7-4 And Complied With Ansi/Tia/Eia 568 C.2 Standard. Jack Should Be Rj11,Rj12 & Rj45 Compatible. Should Support Ethernet 1.2 Gb/S Atm,Digital Video And Broadband/Baseband Analog Video, Voice Over Internet Protocal (Voip) Specifications In Existing Modular/Ms Boxes Along With Necessory Connections As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 61 Cat 6, Un-Sheilded Information Outlet 62 Supply & Fixing Of Square Faceplate For Flush / Surface Mount Information Outlets Single/Dual Or Quad Aperture , Material Should Be Pc+Abs Body, Suitable For Rj45 Unshielded/Shielded Connection Modules. Should Match With I. O. Oem. Dimensions Should Be 86Mm X 86Mm As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 63 Single Aperture 64 Supply , Installation And Testing Of 4 Pair, 100 Ohm Impedance, Cat 6/6A /Class E/Ea Patch Cords Should Be Constructed Of Minimum 23/24 Awg, Stranded Bare Copper Cable With Frpvc/Lszh Jacket, With An Enhanced Performance By Factory Moulded Rj45 Connectors With Strain Relief Boots As Per Ansi/Tia/Eia 568-C.2 Suitable For Cat 6/6A Application Complying To Latest Ammendments Category 6/6A Standards, According. To Tia568C.2, Iso/Iec 11801, En 50173, Iec 60603-7-51, En 60603-7, Ieee 802.3An Minimum Requirement For 1G Base-T To 10G Base-T Performance. Patch Cords Shall Be Straight Thru Cable Compatible With Both T568-A And T568-B Wiring Schemes, Should Support Ieee 802.3Af / Ieee 802.3At For Poe Applications, Minimum 750 To 1000 Mating Cycles In Plug Contacts For Long Durability, Should Support Ethernet 10Gbase-T, 1.2 Gb/S Atm, Token Ring 4/16, Digital Video And Broadband/Baseband Analog Video, Voice Over Internet Protocal (Voip).All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 65 Cat 6, U/Utp (Unscreened/Un-Sheilded Twisted Pair) Patch Cord 66 0.50 Mtr 67 Plate Earthing As Per Is:3043 With Hot Dipped G.I. Earth Plate Of Size 600Mm X 600Mm X 6.0Mm By Embodying 3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 68 Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity >95% Thimble Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 69 8 Swg G.I. ( Hot Dipped ) Wire 70 Sitc Of Ip-42 And General Construction Confirming To Is:8623 : 1993, Wall/ Free Standing Floor Mounted Dust And Vermin Proof Compartmentalised Cubical Panel As Specifications And Other Parameters Required As Per Point (A) ,(B), (C),(D), (E), (F), (G), (H) As Below:- 71 (A)Thickness Of Crca Sheet Shall Be 2.0 Mm, Cable Alley Compartments Having Concealed Hinged Type Doors With Key Type Lock With / Without Detachable Extension Type Structure. Removable 3 Mm. Thick Sheet Steel Gland Plates With Appropriate Size Of Knockouts For Cables Shall Be Provided 72 (B)Complete Panel Shall Undergo A Process Of Degreasing, Water Rinsing, Activation, Derusting, Pickling In Acid Bath, Phosphatising & Shall Be Subjected To Nine Tank Process And Then Powder Coated With Approved Shade Of Minimum 70 Microns On Both Side Of Panel. The Panel Having Pe Foam/ Neoprene Rubber Gasket Of Not Less Than 3Mm Thickness ,Required Hardware , Concealed Hinged Door With Key Type Locking Arrangement For Equipment/Switchgear Earthed With 2.5 Sq.Mm Braided Copper Wire. 73 [C) Interconnection Between Bus Bar And Switchgears /Cable Shall Be Rigidly Supported And Made Out By Flexible Copper Wires (Up To 63 Amp ) And By Solid Bus Bar (>63 Amp ) . Control Wiring Will Be Carried Out With 1.5 Sq.Mm, Earth Wire With 2.5 Sq.Mm And Ct With 2.5 Sq.Mm Flexible Copper Wire Only. All Joints / Interconnections Of Copper Bus Bar Shall Be Dully Tinned . Clearance Between Main Bus Bar And Risers / Metal Parts Shall Be At Least 10 Mm Additional To Width Of Bus Bar Bus Bar Is Insulated By Heat Shrinkable Sleeves . Earth And Neutral Bus Bar Shall Be Half Of The Size Of Phase Bus Bar. ( Cost Of Bus Bar / Flexible Wire For Interconnection Between Main Busbar And Switchgear Is To Be Paid Extra ) 74 (D)Wiring Between Components Within Switchgear And Incoming / Outgoing Cable Shall Be Done Through The Terminal Block Only. Direct Connection Shall Not Be Permitted. Each Terminal Block Shall Be One Piece Moulded, Barrier Type, 650 Volt Grade, Complete With Washers, Heads, Studs With Two Nuts And Identification Strips And Shall Have Adequate Continuous Current Rating. For Tap-Offs, Adjacent Terminals With Shorting Strips Shall Be Used. 10% Spare Terminal Blocks Shall Be Provided. Wire Identification On Marking Strip Shall Correspond To The Designation Of The Wiring Diagrams. All Wire Terminals On The Equipment Shall Also Be Marked With Designation Corresponding To Those Of The Wiring Diagram. 75 (E)All Wiring Shall Be Enclosed In Plastic Channels And Neatly Bunched And Closed In Metering Chamber, Wiring Between Terminals Of Various Devices Shall Be ‘Point To Point’ (No Wire Splitting Or Tee Connections) With Wires Neatly Trucked Along The Back Of The Panels, Adequately Supported To Prevent Sagging. 76 (F)Floor Mounted Panel Shall Be Mounted On Base Frame Of Ismc Channel Size 100 X 50 X 5 Mm ( To Be Paid Extra ) 77 (G) Tests: The Insulation Resistance (With 1000 V Megger) And High Voltage Power Frequency Test (By Applying A Voltage Of 2.5Kv For One Minute) Shall Be Measured Between Phases, Between Phase And Neutral And Between Phase And Earth. Both Before And After High Voltage Power Frequency Test. The Insulation Resistance Shall Not Be Less Than Three Megaohm. Ct Secondary Current Injection Test Shall Also Be Carried Out. 78 (H) Only Outer Surface Area On All Sides Shall Be Measured & Panel To Be Fabricated Only From Cpri Approved Fabricator Only (Cpri Test Certificates To Be Submitted)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 79 Providing & Fixing Of 110/220 V, Unibody Led Indicating Lamp Iec 60947 With Integral Circuit, Ip 65 Above Panel & Ip 20 Terminal Block, Approx. Body Dia For Panel Not Less Then 20 Mm, Length Min. 50Mm, Front Led Cover Dia Min. 29 Mm, Contact Material Phospher Bronze For Led, Pcb Contacts Shall Be Of Brass (Tin Plated), Impulse Dielectric Tested For 2.5 Kv, Rated Insulation Resistance Shall Be 100 M Ohm At 500Vdc Including Connection Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 80 Red/Yellow/Green Colour 81 Blue / White Colour 82 Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy >=125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac And Auto Resetting Safety , Power Factor >0.95 Driver Efficiency >85% ,Thd(I) 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 83 Led Street Light Fixture With Minimum Lumen Output 8700 Lm 84 P/Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 85 1.5 Sq.Mm 3 Core Flat / Round 86 Supply, Installation, Testing And Commissioning Of Bis Compliance Professional Series Diagonal Screen Size 43\ Led With Resolution 3,840 X 2,160 (4K Uhd) Along With Static (Panel) Contrast Ratio (1300:1) Or Better With Viewing Angle Of 178/178 Degree With Response Time Of 8Ms Along With Hdmi In 2.0 - 2 Nos., Usb 2.0 - 2 Nos., Rs 232- 1 Nos., Rj 45- 1 Nos. With Built In Speaker(10W + 10W), With High Speed Processor And Android Or Other Reputed Operating System Along With 4 Gb Ram Along With All Audio And Video Decoder, Stand-By / Sleep / Off Mode Power 0.5 Watt. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. 87 Supply, Installation, Testing & Commissioning Of 1 Kva 1 Phase Input, With Igbt Based Rectifier True Online Double Conversion Robust Design Wide Input Voltage Range: 160-300Vac @ 100% Load (Linearly Derating To 50% Load @ 100Vac Input). Generator Compatible With Wide Input Voltage Window Double Conversion Efficiency >91% & Eco Mode Efficiency Up To 98% 100% Load @ 0~40C Operating Temp. Active Input Power Factor Correction 0.99 O/P Power Factor 0.9 Inbuilt Ovcd (Over Voltage Cut-Off Device) Fully Conform Coated Pcba Adaptable To Harsh Environment Offer Terminal Blocker On 2K/3K Rating To Connect To Big Capacity Equipment Digital Charger Technology Provide 02-10 A Charging Current Easy Understanding Lcd For Convenient Installation Setup With Minimum 60 Minute Battery Back Up (26Ah X 3 Nos Of Smf Batteries Branded And Recommended By Ups Oem, Battery Stand And Interlink Fr Pvc Copper Cable Of Appropriate Size And Lugs), With Required Cabling For Incoming & Outgoing Connection. Ups Should Be Nabl Certified With Ce, Rohs & Bis Compliance. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. 88 Supply, Installation, Testing & Commissioning Of 2 Kva 1 Phase Input, With Igbt Based Rectifier True Online Double Conversion Robust Design Wide Input Voltage Range: 160-300Vac @ 100% Load (Linearly Derating To 50% Load @ 100Vac Input). Generator Compatible With Wide Input Voltage Window Double Conversion Efficiency >91% & Eco Mode Efficiency Up To 98% 100% Load @ 0~40C Operating Temp. Active Input Power Factor Correction 0.99 O/P Power Factor 0.9 Inbuilt Ovcd (Over Voltage Cut-Off Device) Fully Conform Coated Pcba Adaptable To Harsh Environment Offer Terminal Blocker On 2K/3K Rating To Connect To Big Capacity Equipment Digital Charger Technology Provide 02-10 A Charging Current Easy Understanding Lcd For Convenient Installation Setup With Minimum 60 Minute Battery Back Up (26Ah X 6 Nos Of Smf Batteries Branded And Recommended By Ups Oem, Battery Stand And Interlink Fr Pvc Copper Cable Of Appropriate Size And Lugs), With Required Cabling For Incoming & Outgoing Connection. Ups Should Be Nabl Certified With Ce, Rohs & Bis Compliance. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. Please Enable Macros To View Boq Information
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
4.
Educational and Research Institute #10734365 AOC
Notice Inviting Etender For Procurement Of Equipment, Instruments, Machineries, Tools Charts Etc. Related To Laboratories And Workshop Of Engineering Institute For Junior Executives, Dalalpukur, Howrah-711104-1 Dead Weight Pressure Gauge Tester • Bourdon Tube Pressure Gauge As Manometer • Manometer With Transparent Scale • Manufactured From Corrosion Resistant Materials • Components Arranged On Base Plate. • Set Of Weights • Medium For Transmitting Pressure: Hydraulic • Capacity Of 25Kg / Cm2 • The System Is Nickel Chrome • The Weights Are Zink Iron ) 2 Cut Section Model Of Hermetically Sealed Compressor 3 Universal Bevel Protractor ( Accuracy: 0.01 Mm Material: Stainless Steel Diameter: 70 Mm Size: 300 Mm Type: Analog Graduation 5 Min Straightness .00016+ ( .00005Xl / 2 ) ) 4 Cut Section Model Of Lamont Boiler 5 Slip Gauge Set; Special Set ( M87 ) , Grade I, High Grade Steel, 9 Mm Wide & 30-35 Mm Long Cross Section. 6 Utm Machine ( Material:Ms Voltage:220 V Phase: Single Phase Capacity: 10 To 100 Ton Cross Travel: Up To 1000 Mm Weight: 1500 Kg ) 7 Mollier Chart Flex ( 40 × 30 ) 8 Teak Wood; Wood For Pattern Shop Size: 2×1×6 9 Thermal Conductivity Of Metal Rod; • Frame: Made Of M.S. Square Tubes & Sheets, Welded & Powder Coated • Optional Accessories: Rotameter For Water Flow Measurement • Electric Heater : Clamp Heater, Capacity 200 W, Supply 230 V Ac • Insulation Jacket: Made Of Mild Steel, Mild Steel Rod Is Insulated By Asbestos Powder • Diameter Of Metal Rod 25 Mm, Length Of Rod 300 Mm 10 Cut Section Model Of Screw Type Rotary Air Compressor 11.01 Chart Of Velox Boiler With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.02 Chart Of Mollier Diagram With Labelling ( Size: 23’’ X 36’’, Material: Pvc, With Roller ) 11.03 Chart Of T-T-T Diagram With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.04 Chart Of Utm Machine & Sample With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.05 Chart Of Torsion Testing Machine With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.06 Chart Of Iron-Carbon Equilibrium Diagram With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.07 Chart Of Vernier Caliper With Labeling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.08 Chart Of Vernier Height Gauge With Labeling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.09 Chart Of Thread Measurement With Labeling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.10 Chart Of Gear Tooth Vernier Caliper With Labeling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.11 Chart Of Hermetically Sealed Compressor With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.12 Chart Of Domestic Refrigerator With Labeling ( Size:30× 40, Material: Pvc, With Roller ) 11.13 Chart Of Full Pressure Engine Lubricating System With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.14 Chart Of Constant Mesh Gear Box With Labeling ( Size:30× 40, Material: Pvc, With Roller ) 11.15 Chart Of Synchromesh Gear Box With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.16 Chart Of Components Of A Chasis With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.17 Chart Of Knuckel Joint With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.18 Chart Of Intersection Of A Prism And Cone ( Size:30× 40, Material: Pvc, With Roller ) 11.19 Chart Of Projection Of A Straight Line In Different Quadrants ( Size:30× 40, Material: Pvc, With Roller ) 11.20 Chart Of Plummer Block - Details And Arrangement ( Size:30× 40, Material: Pvc, With Roller ) 11.21 Chart Of Centrifugal Pump With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.22 Chart Of Balanced Type Vane Pump With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.23 Chart Of Bent Axis Piston Pump With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.24 Chart Of Lathe Machine With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.25 Chart Of Single Point Cutting Tool Geometry With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.26 Chart Of Screw Jack Assembly With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.27 Chart Of Cotter Joint Assembly And Design With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.28 Chart Of Vertical Drilling Machine With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.29 Chart Of Shaper Machine With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.30 Chart Of Safety On A Lathe Machine ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.31 Chart Of Safety On A Milling Machine ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.32 Chart Of Safety On A Shaper Machine ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.33 Chart Of Safety In Carpentry Shop ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.34 Chart Of Safety In Fitting Shop ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.35 Chart Of General Precaution In Workshop ( Size:30× 40, Material: Pvc, With Roller ) 11.36 Chart Of Cnc Turning With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.37 Chart Of Elements Of Jigs ( Drill Bushes ) With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.38 Chart Of Tig Welding With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.39 Chart Of Mig Welding With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.40 Chart Of Engine Cooling System With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 12 Digital Lab Trainer ( Bread Board Model ) ( Built-In Dc Regulated Power Supply; At Least 8 Logic Input Switches; At Least8 Output Led; Pulse Generator For Clock Frequency ; Patch Chords ) 13 Arduino Uno Board ( Atmega328 ) 14 Experimental Kit To Study Pam, Pwm And Ppm Modulation And Demodulation ( Pulse Generator With Variable Frequency And Amplitude, Pam Modulator And Demodulator, Pwm Modulator And Demodulator, Ppm Modulator And Demodulator ) 15 Ujt Trainer Kit With P.S. & Patch Cord 16 Led Colour Tv Demonstration Kit ( Display Type: Led, Hd: Screen Size: 24: Connectivity: Usb, Hdmi, Av: Test Points To Be Present Minimum 10 Nos.: Switched Faults To Be Provided: Product Tutorial Should Be Present ) 17 Microwave Oven Demonstration Trainer Kit ( Type: Solo: Capacity: 17 Ltr.: Control Type:Mechanical: All Circuits & Panels To Be Mounted On-Board: Test Points To Be Provided To Analyze Signals: Instruction Manual To Be Provided ) 18 Washing Machine Demonstration Trainer Kit ( Application: Lab Experiment: Semi-Automatic: Tank Capacity: 6.5 Kg: Block Diagram & Circuit Diagram To Be Mounted On The Lid: Test Points To Be Provided ) 19 Mobile Communication Trainer Kit To Study Various Signalling And Fault Insertion Techniques ( Gsm Handset Trainer Kit.  Operate Both On Windows And Linux Platform  Usb Interface For Communication  Best Suitable For Iot Gateway Application  External Connector To Interface With Any Microcontroller  Easy Understanding Of At Commands  Real Time Operation  Built In Network Status Led  Audio Interface Connector  Simple / Easy Operation  External Antenna  Application Module Relay Interface For Ac Device ( Optional ) ) 20 Trainer Kit For Mobilephone Set To Study Transmitter And Receiver Sections In Mobile Handset And Measure Frequency Band Signal ( Real Time Mobile Operation # Full Understanding Of Mobile Phone Working # Frequency Measurement And Band Verification # Provides Study Of All Sections In Mobile Phone # Tx / Rx Frequency Measurement # 3G / 4G Technology And Gmsk Signals # Gsm Data Rate # Detail Study Of User Interface Control Signals # Detail Study Of Sim Operation # Battery Identification And Charging Study  Switched Faults 21 Consumable ( 9V Battery, Cro Probe, Digital Ics ) 22 Cro ( 20 Mhz , Dual Trace, Dual Channel ) 23 Trainer Kit For Mobile Phone ( Features : The Experimental Kit Will Be Capable I ) To Study General Block Diagram Of A Mobile Phone. Ii ) To Study Mobile Transmission Section. Iii ) To Study Mobile Reception Section. Iv ) To Study Different Nos. Of Faults Provided With The Trainer. V ) To Study & Observe Voltages / Waveforms Of Each Test Points. Vi ) To Study Mobile Charging Circuits. Vii ) To Use Mobile Phone As Modem For Using At Commands As Given; A ) Sending Text Messages, Read / Delete Massages Etc. B ) Calling To A No, Reject / Accept The Incoming Calls Etc. C ) Gprs Related Commands. Study Of Bluetooth Technology & Connection With Other Bt Devices. Bluetooth Profiles : Bip, Bpp, Dunp, Ftp, Hid, Opp , Sap, A2dp, Pbap, Spp Etc. To Study General Idea Of Sim Card. ( Local Sim Card Must Be Inserted By The User At The Time Of Experiment ) . ) 24 Salt Bath Furnace For Heat Treatment ( • Resistance Heating ( Element ) • Operating Temp.: Up To 1200°C • Digital Temp. Controller ( Pid ) • Chamber Size : 450Mm X 300 Mm X 300 Mm • Furnace Uniformity + / - 2°C • Temp Recorder With 2 Channel Placed At Opposite Sides • Salt For Use With Two Times Top Up • Spare Heating Element 2Pc ) 25 In-Situ Metallography Kit ( • Items: Portable Grinder / Polisher, Grinding Discs, Lapping Cloths, Diamond Pastes, Aerosol Spray, Replication Film, Paste, Reflector And Gumming Tape For Excellent Contrast Or Transparent Replica - Film Thickness - 125 Microns, 30 Microns, Replica Liquid, Glass Slides ) 26 Automatic Electrolytic Polishing Machine ( • Function: Fully Automatic Electrolytic Polishing And Etching With Automatic Scanning Function • Preparation Time: Within 30 Sec • Electrolyte For Low / High Alloyed Steels & Aluminium • Pump And Magnetic Stirrer • Integrated Cooling System ) 27 Micro-Hardness Tester ( • Test Load : 10, 25, 50, 100, 200, 300, 500, 1000 Gm • Scale: Knoop & Vickers • Dwell Time: 5-90 Seconds Settable • Objectives : 10X, 20X, 40X, 60X • Loading And Unloading : Motorized • Measurement – Automatic And Or With Manual Micrometer Eyepiece. • Traverse: Automatic And Or Manual With Micrometer. • Focusing - Motorized Focusing With Manual Over-Ride • Computerized Imaging Attachment, Dedicated Software To Measure Hardness On Computer With Report Generation Facility • Accessories: Sheet Holder, Wire Holder, Hardness Test Block, Bulb, Indenter. ) 28 Cracked Aluminum Test Block ( For Penetrant Sensitivity Checking In Dpt ) ( Aluminum Test Piece That Measures 3 X 2 X 3 / 8 With A 1 / 8 Wide With A Milled Notch That Separates The Blocks Two Sides To Facilitate Side-By-Side Penetrant Comparison. The Test Block Is Used To Check The Strength Of “In-Use” Penetrants. This Is Done By Processing One Half Of The Block With “Used” Penetrant, And The Other Half With Fresh Penetrant. Can Be Used To Compare Sensitivity Of Different Penetrants Or Sensitivity Of New And Old Penetrants. Complies With Astm E165 And Asme Boiler And Pressure Vessel Code Section V & Iii, And Mil-I-23135-C. ) 29 Pie Gauge / Magnetic Flux Indicator ( To Be Made From Eight Ferrous Segments, Braised Into A Single Piece, Providing A Star Pattern Of Nonferrous Discontinuities. Eight Linear Discontinuities To Provide Indications In All Directions Non-Ferrous Handle With Pivot. Specification Compliance • Mil-Std-271 • Astm E709 ) 30 20Mhz Analog Cro ( Dual Trace ) , Bandwidth:- Dc ~ 20Mhz ( -3Db ) Y Deflection:- 5Mv / Div ~ 10V / Div. Rise Time:- <18Ns,Mag _70Ns :17.5Ns. Max Input:- 400V ( Dc+Acp-P ) 31 50Mhz Digital Storage Oscilloscope, Bandwidth 50Mhzreal-Time Sampling Rate 500 Msa / S, Equivalent Sampling Rate 50Gsa / S.Memory Depth: 32Kptstrigger Types: Edge, Pulse Width, Video, Slope, Alternativeunique Digital Filter Function And Waveform Recorder Function, Max Input:- 400V ( Dc+Acp-P ) 32 3D Model Showing Different Parts Of A Coal Fired Thermal Power Station 33 3D Model Showing Different Parts Of A Gas Fired Thermal Power Station 34 3D Model Showing Different Parts Of A Diesel Power Station 35 3D Model Showing Different Parts Of A Nuclear Power Station 36 3D Model Showing Different Parts Of A Hydro-Electric Power Station 37 3D Model Of Boiler Showing Its Different Parts Used In Coal Fired Thermal Power Station 38 3D Model Of Boiler Showing Its Different Parts Used In Nuclear Power Station 39 3D Model Of Water Turbine Showing Its Different Parts, Used For Hydro-Electric Power Plant 40.1 Colour Flex Chart Describing Different Parts Of A Coal Fired Thermal Power Station Size:30× 40, Material: Pvc, With Roller 40.2 Colour Flex Chart Describing Different Parts Of A Gas Fired Thermal Power Station Size:30× 40, Material: Pvc, With Roller 40.3 Colour Flex Chart Describing Different Parts Of A Diesel Power Station Size:30× 40, Material: Pvc, With Roller 40.4 Colour Flex Chart Describing Different Parts Of A Nuclear Power Station Size:30× 40, Material: Pvc, With Roller 40.5 Colour Flex Chart Describing Different Parts Of A Hydro-Electric Power Station Size:30× 40, Material: Pvc, With Roller 40.6 Colour Flex Chart Describing Different Parts Of Boiler, Used In Coal Fired Thermal Power Station Size:30× 40, Material: Pvc, With Roller 40.7 Colour Flex Chart Describing Different Parts Of Boiler, Used In Nuclear Power Station Size:30× 40, Material: Pvc, With Roller 40.8 Colour Flex Chart Describing Water Turbine Showing Its Different Parts, Used For Hydro-Electric Power Plant Size:30× 40, Material: Pvc, With Roller 41 3-Phase Induction Motor Speed Control Using Pwm Inverter For Interpreting Speed-Torque Characteristics Using Vvvf Drive 42 Ups Trainer Kit ( 1Kva ) Output Voltage : 230 V Ac Nominal, Input Voltage : +12V Dc Battery. Capacity : 1Kva, Output Frequency : 50 Hz Accuracy : + 5%. Switching : Automatic. 43 Smps Trainer Kit Incl. ±5V, ±12V Input Voltage: Ac 100 – 264V 50 / 60Hz Output Voltage: 12V Dc, 0-5A Output Voltage: Adjustment Range: ±20% Protections: Overload / Over Voltage / Short Circuit Auto-Recovery After Protection Universal Ac Input / Full Range 100% Full Load Burn-In Test Cooling By Free Air Convection High Quality And High Performance Led Power Supply With A Metal Body For Hidden Installation For Led Lighting Design With Built-In Emi Filter, Improve Signal Precision. Certifications: Ce & Rohs No Minimum Load. Compact Size Light Weight. High Efficiency, Reliabiltiy & Low Energy Consumption Controller: Satandard 44 Commutation Kit Of Scr ( Class A To F ) Completely Self – Contained Stand – Alone Unit. Demonstrates The Principle And Various Methods Of Forced Commutation Of Scr. 1. Self-Commutation By Resonating Load ( Class “A” Method ) . 2. Self-Commutation By An L C Circuit ( Class “B” Method ) . 3. Complimentary Commutation ( Class “C” Method ) . 4. Auxiliary Commutation ( Class “D” Method ) . 5. External Pulse Commutation ( Class “E” Method ) . * Supply Required 230V, 50Hz Ac. * Built-In Ic Based Dc Regulated Supply And Led Indication For Supply “On”. * Built-In Load Facility In The Form Of Led’S. * Connecting Each Circuit Separately And Verifying Its Principle. * Multicoloured Test Points Are Provided To Observe The Waveform And Voltages. * Set Of Required Number Of Patch Cords. * Housed In An Elegant Cabinet With A Well Spread Intelligently Designed Circuit Layout Engraved On The Front Panel. * Strongly Supported By A Comprehensive Instruction Manual Complete With Theory And Operating Details. 45 Colour Flex Chart Describing Single Line Diagram Of A Given Distribution System ( Lt & Ht ) Size:30× 40, Material: Pvc, With Roller 46 Colour Flex Chart Describing Short Transmission Line ( 220Kv ) Size:30× 40, Material: Pvc, With Roller 47 Colour Flex Chart Describing Medium Transmission Line ( 220Kv ) ( Both T & Π-Model ) Size:30× 40, Material: Pvc, With Roller 48 Power Factor Improvement Kit Using Static Condenser Including Load R-L Load Of At Least 2Kva With Appropriate Capacitor Bank. 49 Setup For Load Test On 1-Ph Induction Motor: Load Test Kit Of 1-Ph Induction Motor ( 1Hp, 230V, 50Hz ) 50 Loading Test Kit Of 3-Phase Alternator: ( 2Kw, 415V, 50Hz ) With 3-Ph R-L Load Box Coupled To A Dc Motor; Capable To Perform As Synchronous Motor Test With Dc Generator Load; Integrated With All Required Measuring Instruments 51 Speed Control Kit Of Stepper Motor Including Reversing Arrangement With 8051 Microcontroller: Stepper Motor Of Appropriate Capacity To Be Served By 8051Μc 52 Speed Control Kit Of Ac Servo Motor: Motor Spec: 3000Rpm, 200W, 0-240V, Control Torque: Standard With All Needed Accessories 53 Speed Control Kit Of Dc Servo Motor: •Voltmeter Vdc 3.5 Digit. 200Mv •Rpm Indicator For Speed Measurement •Voltmeter Vdc 3.5 Digit 20V Power Supply: •Ic Regulation In Controller Circuit Power Supplies •Operated On Mains Power 230V, 50Hz +10% Features: •Position Control Of A 12 Volt, 1 Amp Dc Geared Pm Motor ( 50 / 60 Rpm ) •Calibrated Dials With 1 Degree Resolution For Reference And Output Position •Two 360 Degree Servo-Potentiometers •Built In Step Signal •Built In Waveform Capture / Display Card For Study Dynamic •Electronic Techogenerator For Feedback •Non-Contact Eddy Current Break For Load •Speed Control Of 12V, 4W, Permanent Magnet Dc Motor •Speed Range Up To 3000 Rpm ( Typical 54 Mcb Test Kit For Performing Load Test: Kit Should Be Able To Perform Short-Circuit, Over Load, Thermal Trip Test For Mcb With Rating Upto 30A 55 Dismantled Elcb & Rccb Kit For Demonstration Purpose: Elcb: Single Phase 2 Pole Elcb, Rccb, Isi Marked 32A Mcb With High Voltage, Overload Protection, Current 3 To 30 Ma Rccb: Breaking Capacity 10 Ka, Frequency, 50 Hz, Number Of Poles 2P, Operating Characteristics: Ac Rated Current 40 A, Sensitivity 30 Ma, Standard, Is 12640-1 & Iec 61008-4, Test Button Yes 56 Testing Kit For Percentage Differential Protection Of Transformer Using Transformer Differential Relay ( Electromagnetic / Μp Based / Static ) : Standard For Laboratory Purpose 57 Colour Flex Chart Describing Different Parts Of Acb & Vcb ( 33Kv, 15Mva ) : Size:30× 40, Material: Pvc, With Roller 58 Experiment Kit To Measure Solar Radiation Using Pyranometer On Tilted Surface At Different Angle Inclination: Standard For Laboratory Purpose 59 Colour Flex Chart Describing Different Parts Of Solar Flat Plate Collector & Solar Concentrating Collector & Trough Collector: Size:30× 40, Material: Pvc, With Roller 60 Experiment Kit To Measure Thermal Performance Of Solar Water Heating System: Standard For Laboratory Purpose 61 3D Model Describing Different Parts Of ( I ) Solar Street Lighting System & ( Ii ) 1Kw Small Wind Turbine ( Swt ) : 3D Model For Laboratory Purpose 62 Setup Of 250Wp Solar Pv Plant Including All Accessories: Solar Panel Specifications:Peak Power: 250W; Maximum Power Voltage: 20.2V; Maximum Power Current: 12.38A; Open Circuit Voltage: 23.9V; Short Circuit Current: 13.12A; Power Allowance Range: + / - 3% Hybrid Inverter Specifications: Nominal Battery Voltage: 12V; Continuous Power Output: 1000W / 1000Va; Surge Power: 2000Va Output Voltage: 230V Ac; Output Frequency: 50Hz / 60 Hz; Output Waveform: Pure Sine Wave; Maximum Solar Input Power: 600W; Maximum Open Circuit Solar Input Voltage: 55V; Maximum Solar Charging Current: 50A; Maximum Mains Ac Charging Current: 20A; Maximum Combined Charging Current: 50A; Peak Efficiency: 93% Battery Specifications ( Per Battery ) : Nominal Voltage: 12V; Nominal Capacity: 50Ah ( 10H Rate ) / 55Ah ( 20H Rate ) ; Maximum Charging Current: 25A; Self-Discharging Rate: <3% Per Month; Cycle Lifetime At 30% D.O.D.: 1000-1100 Pressure Control: Safety Valve Installed Terminal Type: F13 ( Bolts And Washers Included ) Operating Temperature: From +10C To +40C 63 Setup Of Small Wind Turbine Plant Including All Accessories: Standard For Laboratory Purpose 64 Study Kit Of Assembling And Dismantling Of Csp Plant Using Parabolic Trough Or Disc: Standard For Laboratory Purpose 65 Study Kit For Assembling Vertical Axis Or Horizontal Axis Swt: Standard For Laboratory Purpose 66 Digital Lcr Multimeter: Digital Lcr Meter ( Battery Operated ) , Model: 4070 Range: 0.1Μh To 20H, 0.1Pf To 2000Μf, 0.1Ohm To 20Mohm Accuracy: 2Mh, Resolution: 1Uh, Accuracy: 20Mh, Resolution: 10Uh, Accuracy: 200Mh, Resolution: 100Uh Accuracy: 2Nf, Resolution: 1Pf, Accuracy: 20Nf, Resolution: 10Pf, Accuracy: 200Nf, Resolution: 100Pf, Accuracy: 2Uf, Resolution: 1Nf, Accuracy: 200, Resolution: ± ( 0.8 Percent+5 ) 0.1, Accuracy: 2K, Resolution: 1, Accuracy: 20K, Resolution: 10, Accuracy: 200K ( Make: Metravi ) 67 Handheld Power Meter Or Power Analyzer With Socket: Voltage: 85V-265V, Current; 0.002A~20A, 50Hz, 1-Ph 68 Analog Power Factor Meter ( 1-Ph & 3-Ph ) : Standard For Laboratory Purpose 69 Multimeter With Clamp Meter Arrangement With Hfe Lcr: Standard For Laboratory Purpose ( Make: Metravi ) 70 Three Phase Power Measurement Kit ( Y & Δ Load R-L Load ) Incl. 3-Ph Wattmeter With 2Kw Range: Standard For Laboratory Purpose 71 Kit For Troubleshooting Single Phase Electronic Energy Meter: 230V, 1-Ph, 50Hz 72 Three Phase Trivector Meter: Salient Features Class 0.5S As Per Relevant Is And Iec Standards 5A Current Rating 3 Phase 4 Wire 4 Quadrant Measurement Anti-Tamper Features Self-Diagnostic Capability Multiple Tariff / Time Of Day Feature Bidirectional Energy Recording Up To 4 Maximum Demand Registers Load Survey ( Interval Data ) Features Up To 12 Reset Backups Optical Port / Rs 232 / Rs 485 / Ir / Irda / Rf ( 2.4 Ghz / 865-867 Mhz ) ( Optional ) ( Make: L&T ) 73 Brake Test Kit Of Dc Series Motor: 220V Dc, 2Hp With Allied Required Accessories 74 Back-To-Back Test Kit Of Single Phase Transformer: 1-Ph, 240V, 50Hz, 1Kva ( 2 Nos. ) Identical Transformers With Other Standard Accessories 75 Isolation Transformer Kit: 230V; 230V / 10Amp 230V; 230V / 5Amp 76 Pulse Transformer Kit: Dc Supply: Two 5V & 12V, Pulse Generator: Two Selectable Frequency & Variable Pulse Width, Mains: 230V / 50Hz, Adequate For Cro Observations, Optocoupler: One, One Ferrite Wired 1:1 77 Colour Flex Chart Describing Different Vector Groups Of Theree Phase Transformer: Size:30× 40, Material: Pvc, With Roller 78 Full-Wave Fully Controlled Bridge Rectifier Kit With & Witout Filter Arrangement: Standard For Laboratory Purpose 79 Kit To Find The Characteristics Of Zener Diode: Standard For Laboratory Purpose 80 Kit To Find The Characteristics Of Mosfet: Standard For Laboratory Purpose 81 Ujt Relaxation Oscillator Trainer Kit: Standard For Laboratory Purpose 82 Singlestatge Transistor Trainer Kit ( Ce-Mode ) : Standard For Laboratory Purpose 83 Trainer Kit For Sr, D, Jk & T – Flip-Flop: Standard For Laboratory Purpose 84 Trainer Kit For Realization Of Encoder And Decoder Circuit: Standard For Laboratory Purpose 85 Trainer Kit For Realization Of Multiplexer And Demultiplexer Circuit: Standard For Laboratory Purpose 86 Trainer Kit For Implementing Dac & Adc: Standard For Laboratory Purpose 87 Connector Cables For Ade Lab. Of Different Types: Standard For Laboratory Purpose 88 Arduino Uno R3 Board With Lcd1602, Servo Motor, Relayes, Processing And C Code, Beginner Starter Kit With Mannual And Allied Accessories: Standard For Laboratory Purpose 89 Trainer Kit For 8051 Μc Programming: Trainer Kit For 8051 Μc Programming With Keypad To Write Program 90 Trainer Kit Using 8051 Μc For Measurement Of Ac Voltage, Current, Frequency & Phase Angle Using Suitable Ct, Pt, Zcd, Adc, Etc. 91 Demonstration Kit For Identifying Pvc, Xlpe, Vir, Catenary, Frls, Frlsh Cables / Wires Of Different Current Rattings: Standard For Laboratory Purpose 92 Megger: Insulation Tester ( 500V ) With Hand-Driven Gen.: 500V, 2500 Mega Ohms 93 Megger: Insulation Tester ( 2500V ) With Hand-Driven Gen. 2.5Kv, 2500 Mega Ohms 94 3-Ph Smart Energy Meter For Lt Power Measurement, 3-Ph, 415V, 4-Wire, Kwh Meter, Current: 10-60A, Class 1.0 Accuracy As Per Relevant Is And Iec Standards, With Lcd Display [ Make: L&T ] 95 Trainer Kit For Dc Chopper Drive With Resistive Load & Dc Separately Excited Motor. 1 / 8 Hp, 200Vdc Operation, Current Limit Protection, Speed Control Using Frequency And Duty Cycle Variation, Jones Chopper Based Control, Motor Loading Arrangement Can Be Provided / Resistive Load May Be Connected, Other Variety Of Controllers With Converter Control With Closed Loop Controller 96 Trainer Kit For Controlling The Speed Of Separately Excited Dc Motor By Changing The Firing Angle Of Scr Using 1-Ph Full Converter. Power Supplies: • Power Supply +15Vat 150Ma • Isolated Supply 0-220V At 5A. • Operated On Mains Power 230V, 50Hz +10% Digital Meters: • Voltmeter 2000V Ac • Voltmeter 2000V Dc • Ammeter 2A Dc Components Are Mounted On The Panels Are: • Scr Tyn604 ( 2 Nos. ) • Diode 1N5408 ( 2Nos. ) • Diode Ba159 • Ac Phase Control By Gate Control Firing Circuit. • Snubber Circuit. Load: • 1 / 2Hp Dc Shunt Motor. • Inductor As Load 230V, 1A • Lamp Load 230V, 60W 97 Μcontroller Based 3-Ph Syn. Motor Drive: Trainer Kit For Controlling The Speed Of Synchronous Motor ( 1Kva ) Drive Using Μc. 98 Demonstartion Kit Showing Different Types Of Power Semiconductor Devices With Heat Shink E.G. Scr, Igbt, Gto, Mosfet, Standard For Laboratory Purpose. 99 Kit For Magnetic Control Of Im: Control And Power Circuit For ( I ) Forward And Reverse Rotation Of Squirrel Cage Im Using Contactor, ( Ii ) Automatic Star-Delta Starter Of Squirrel Cage Im, ( Iii ) Dynamic Braking Of Squirrel Cage Im, Standard For Laboratory Purpose. 100 Screw Driver Set, Standard For Laboratory Purpose. 101 6” Slide Range, Standard For Laboratory Purpose. 102 Wire Stripper, Standard For Laboratory Purpose. 103 Crimping Tool ( 1 Sq. Mm. To 6 Sq. Mm. ) . 104 2.5 Sq. Mm. Stranded Pvc Copper Wire 105 1.5 Sq. Mm. Stranded Pvc Copper Wire 106 1 Sq. Mm. Stranded Pvc Copper Wire 107 Soldering Kit: 20W With Solder Material 108 Contact Type Tachometer ( Range: 0-10, 000 Rpm ) 109 Set-Up With Different Type Tl Lamps ( Conventional & Led ) With Fittings Containing Electrimagnetic Ballast / Electronic Ballast Etc.: Tl Fittings With: 1. Electronic & Electromagnetic Ballast For ( I ) Single 40W, 240V, 50Hz Tl, ( Ii ) 2X40w, 240V, 50Hz Tl, 2. 20W Led Tl With Fittings Incl. 110 3-Ph Capacitor Bank Of 2-4Kva For Correcting Power Factor Of 415V, 50Hz, 1500 Rpm, 2Hp, 3-Ph Squirrel Cage Im With Facility To Connect The Stator Of The 3-Ph Im Both In Star & Delta Mode And A Tri-Vector Meter Having Facility To Measure Kw, Kva, Kwh, Kvarh, Pf. 111 Transformer Oil Breakdown Strength Kit: Breakdown Strength Kit With 5 Ltr. Fresh Transformer Oil, Standard For Laboratory Purpose. 112 Chart For Demonstration Of Different Fire Extinguishers: Colour Flex Chart Describing Different Types Of Fire Extinguishers ( 4 X 3 ) , Material: Pvc, With Roller 113 Chart For Demonstration Of Artificial Respiration ( Cpr ) And Prepare A Report.: Colour Flex Chart Describing Different Types Of Artificial Respiration ( Cpr ) ( 4 X 3 ) , Material: Pvc, With Roller.
Contract Date: Dec 10, 2024 Contract Value : 11.21 Lakh
Government Departments No of Bidders 3
West Bengal View Result →
5.
Power #10591948 Price Bid
tender for WORK OF REPLACEMENT OF EXISTING 100 MVA 220 / 132 KV TRANSFORMER (EMCO MAKE) WITH NEW 160 MVA 220 / 132 KV TRANSFORMER (TAL MAKE) AND OTHER ASSOCIATED WORKS AT 220 K.V. SUB STATION KURSI ROAD UNDER E.T.D. - II, LUCKNOW Sl. No. Item Description 1 Following Works are to be carried out at 220 K.V. Sub Station Kursi Road, Lucknow for replacement of existing 100 MVA 220 / 132 KV Transformer (EMCO make) by new 160 MVA 220 / 132 KV Transformer (TAL make) alongwith associated works against Increasing Capacity including all cost of men, T&P, Crane, 6 - 12 KL / Hr. capacity Centrifuging Machine with Operator, Carriage Vehicle etc. to complete the job satisfactorily as per direction of site Engineer : 2 Draining of Oil from 100 MVA EMCO make Transformer at 220 KV Sub Station Kursi Road into 209 Liter Capacity Oil Drums. 3 Dismantling of existing 120 KV LAs alongwith associated structures instailed in 100 MVA 220/132 KV Transformer Bay after due cutting of earthing, opening of jumpers etc. (1 Job per L.A. with structure). 4 Complete dismantling of all the water & air pipe lines, pipe supports etc. of Emulsifire Systern around the 100 MVA 220/132KV Transformer alongwith Shifting & Stacking of all the dismantled items at safe storage place at the Sub Station. 5 Opening of HV & LV side Jumpers, Removal of Neutral & Main Tank Earthing, Opening of Control / Power Cable Connections of 100 MVA 220/132 KV Transformer including opening of connections of associated OLTC & Marshalling Box. 6 Complete safe Dismantling of the accessories of 100 MVA 220/132 KV Transformer including opening of Jumpers, removal of earthing, opening of Cable connections, Removal of Conservator Tank, Pipe Lines, Bushings, Cooling Fans & Pumps, Marshaling Box, Radiators after Draining of Radiator Oil in empty Drums then fixing of blanking plates on the radiators, pipe lines, conservator tank turret etc. (Suitable Blanking Plate including Bolts & Nuts as required if not available at substation, shall be provided/arranged by the Contractor.) 7 Safe Shifting & proper Stacking at storage place of all the dismantled accessories of 100 MVA 220/132 KV Transformer i.e. Conservator Tank, Pipe Lines, Bushings, Cooling Fans & Pumps, Marshaling Box, Radiators, Headers, A Frame etc. and T/F Oil Drums at the safe storage place at the Sub Station. 8 Proper packing of HV/LV neutral bushings of the dismantled 100 MVA 220/132 KV Transformer in separate wooden cases / crates of the bushings after proper wrapping of bushing with polythene sheet alongwith reparing of wooden cases, to be provided by contractor. 9 (A) Shifting of Main Tank of the dismantled 100 MVA (EMCO make) 220/132 KV Transformer from the Plinth up to 20 Meter distance including turning of Tank, as required. 10 (B) Additional Shifting of the tank of above transformer upto 200 Meter distance. (01 Job for every 5 Meter and / or part there of) 11 Dismantling and shifting of existing 100 MVA TF RTCC panel from ACDB room including opening connection of control cables , identifying cables for future connection & shifting RTCC panel at place of storage as per instructions of supervising engineer (SDO/JE) 12 (A) Shifting of Main Tank of the new 160 MVA (TAL make) 220/132 KV Transformer to its Plinth from Place of Unloading up to 20 Meter distance including turning of Tank, as required. 13 (B) Additional Shifting of the tank of above transformer upto 120 Meter distance. (01 Job for every 5 Meter and / or part there of) 14 Complete erection of the 160 MVA (TAL make) Transformer including its radiators, conservator tank, turrets, connecting pipe lines, HV / HV / neutral bushings, cooling fans, OLTC drive mechanism box, marshalling box, OTI, WTI, capillary tubes etc. 15 Supply of dry Nitrogen gas having DEW point (-60°C to -65°C) under vacuum fro top valve of the transformer upto pressure of 2PSI (as per tehcnical norms of Transformer) and maintaning the same in the main tank for 12 Hrs. including cost of nitrogen gas and nitrogen gas filling device for dry cycle. 16 Create the vacuum inside the T/F tank & maintain it for 24 Hrs. dry air cycle of T/F creating vacuum inside the main tank of T/F, maintaning it for 24 Hrs. then filling of dry air bearing dew point (-60°C to -65°C) for 24 Hrs. And repeating the same till the PPM value of main tank is achieved below 05 PPM filling the oil step by step in 160 MVA T/F. 17 Centrifuging of completed T/F oil in T/F oil tank by connecting centrifuging machine to be provided by the contractor and taking the BDV,PPM & IR values of the oil & TF bushings periodically till the required value in achieved as per direction of Supervising Engineer (Centrifuging machine, BDV & PPM machine, megger shall be arranged by the contractor). After centrifuging ,DGA test of oil sample is to be carried out. 18 Carriage of oil tank of 20KL (01 Nos) capacity from 220 KV S/S Chinhat to 220 KV S/S Kursi Road distance upto 20 KM including loading and unloading at respective place and after work completion. Carriage of oil tanks of 20 KL (01 Nos.) from 220 K.V. Sub Station Kursi Road to 220 KV S/S Chinhat. 19 Delta earthing of 160 MVA Transformer consisting of fabrication of delta set with 03 Nos. 40 mm / 33 mm dia size 03 Mtr. ling electrode, its placing inside ground and connecting all the these electrode with 75x10mm M.S. Flat 700 mm deep and connecting the same with earthmat at two places. Also connecting delta to earth mat of substation at two places as per drawing provided by site engineer from UPPTCL. The work also to be done for painting the welding joint in black colour below earth level and green colour above ground level in two coats. (MS Rods & MS Flat will be provided by the department free of cost). 20 Erection of 132 KV LAs including erection of associated ALP structures, earthing of the LAs with existing M.S. Flat and jumpering with ACSR Zebra Conductors to connect with 132 KV Jack Bus with the help of ACSR Zebra Conductor, associated terminal connectors, P.G. Clamps etc. (01 Job per LA with associated structure). 21 Jumpering of HV side bushing of the 160 MVA transformer to connect with HV side CTs through 220 KV LAs with ACSR Zebra Conductor, associated terminal connectors etc. 22 Jumpering of LV side bushing of the 160 MVA transformer to connect with LV side CTs through 132 KV LAs with ACSR Zebra Conductor, associated terminal connectors, PG Clamps etc. 23 Laying of following size control cables from C&R panel to marshalling box/equipment/ junction box etc in switch yard for new 160 MVA T/F as per cable schedule along with saddling at every 750mm distance with MS saddles of size 25x3 sq mmincluding carriage of cable drums from store to laying site and shifting back remaoning drumsto store after work completion. The work shall also include interconnection of control cables with marshalling box , OLTC panel to RTCC panel, ferruling, dressing of cables and other associated works for satisfactory completion of job as per technical specificatons: 24 2C x 2.5 sq mm 25 4C x 2.5 sq mm 26 6C x 2.5 sq mm 27 10C x 2.5 sq mm 28 Erection of new 160 MVA TF RTCC panel including shifting from place of storage to ACDB room as per directions of site engineer (SDO/JE). 29 Earthing of main tank, marshalling box, drive mechanism, Transformer neutral, , RTCC panel etc of new 160 MVA Transformer with 50 x 6 mm and 75 x 10 mm size MS flats, its jointing with already existing earth mats/ deltas including necessary modification in existing support for earthing of neutral bushing for its earthing work and then painting of earthing strips as per technical specifications. 30 Making termination / connection of the control & power cables as per new cable schedule of 160 MVA Transformer, RTCC Panel, control & relay panel, cooling fans, pumps, marshalling box. OLTC, driving mechanism etc. dressing & binding of additional control cables, if required as per site requirement alongwith making necessary holes in the gland plate / box, wherever required including providing & fixing of cable glands of appropriate sizes providing of ferrules etc. 31 Testing of new 160 MVA Transformer 32 Conducting test of 160 MVA T/F (M/s TAL make) by arranging appropriate equipments for following items :-i. DGA test of Transformer oil & Water Content Test of Transformer oil 33 Conductioning test of 160 MVA T/F (M/s TAL make) by arranging appropriate equipments for following items :-1. WRM-01 No.2. Tan Delta-02 No. (Pre-erection and post-erection)3. Turret CT Ratio. Polarity, Knee Point continuity & I.R. Test 34 Work of re-erection, hydraulic testing, & commissioning of water spraying and fire detection mulsifyre system comprising of following detailed pipe lines with all cost of men, material, T&P etc required for the job as per details below: 35 Supply and installation of 80 mm dia B-class GI pipe for support with round clamp at top & flanges at bottom as per specifications including grouting and painting etc. 36 Providing, laying, installation , testing and commissioning of new 50 mm dia B class GI pipe with elbows, Tees, sockets, flanges, bends etc including its painting and connection to already dismantled existing pipe lines ( as may be required) 37 Providing, laying, installation , testing and commissioning of new 40 mm dia B class GI pipe with elbows, Tees, sockets, flanges, bends etc including its painting and connection to already dismantled existing pipe lines ( as may be required) 38 Providing, laying, installation , testing and commissioning of new 25 mm dia B class GI pipe with elbows, Tees, sockets, flanges, bends etc including its painting and connection to already dismantled existing pipe lines ( as may be required) 39 Supply, installation of HV nozzle projector HD make. 40 Supply, installation , testing of QB detector 41 Laying, installation, testing & commissioning of old G.I. Pipe B Class including cutting, welding etc. and providing suitable Flangs alongwith necessary fitting viz bends, elbow, tees, reducer, gasket etc.:- 42 25 mm dia. G.I. Pipe 43 50 mm dia. G.I. Pipe 44 65 mm dia. G.I. Pipe 45 80 mm dia. G.I. Pipe 46 100 mm dia. G.I. Pipe 47 150 mm dia. G.I. Pipe 48 Installation of HV nozzle projector 49 Installation of HV HD Fire detector 50 Erection, hydraulic testing & commissioning of complete mulsifyre system by installation of high velocity water spraying & fire detection system on 160 MVA 220/132KV TF by using old dismantled/newly laid additional pipe lines including providing of new gaskets/packings of required sizes along with necessary welding / jointing and earthing of pipe supports after re-construction of damaged RCC foundation for pipr supports. 51 Painting of above installed water spraying & fire detection system on 160 MVA 220/132KV TF in 02 coats of synthetic enamel paint after due application of 01 coat of red oxide primer after removal of old paint by rubbing with emery paper. The water pipe lines shall be painted in P.O. red color , Air pipe lines in sky blue color,Pipe supports in black color, earthing strips in Bus green color. 52 Electrical Safety processing fees needed for providing all relvant safety clearance documents from electrical safety department for energisation of the above commissioned 160 MVA Transformer and its accessories (Note: The amount payable is actual rate of challan or quoted rate, whichever is lower) 53 160 MVA Power Transformer 54 All LA (220/132 KV) associated with newly commissioned 160 MVA Transformer 55 HT inspection fees 56 Work of re-erection, hydraulic testing, & commissioning of water spraying and fire detection mulsifyre system on 132/33 KV 63 MVA M/s Atlanta make Transformer, comprising of following detailed pipe lines with all cost of men, material, T&P etc required for the job as per details below: 57 Providing, laying, installation , testing and commissioning of new 150 mm dia B class GI pipe with elbows, Tees, sockets, flanges, bends etc including its painting and connection to already dismantled existing pipe lines ( as may be required) 58 Supply and installation of 80 mm dia B-class GI pipe for support with round clamp at top & flanges at bottom as per specifications including grouting and painting etc. 59 Providing, laying, installation , testing and commissioning of new 40 mm dia B class GI pipe with elbows, Tees, sockets, flanges, bends etc including its painting and connection to already dismantled existing pipe lines ( as may be required) 60 Providing, laying, installation , testing and commissioning of new 25 mm dia B class GI pipe with elbows, Tees, sockets, flanges, bends etc including its painting and connection to already dismantled existing pipe lines ( as may be required) 61 Supply, installation of HV nozzle projector HD make. 62 Supply, installation , testing of QB fire detector 63 Replacement of diaphragm along with re-installation of quick opening flood, deluge valve HD make 150NB as per maximum working pressure 10kg/sq mtr of deluge valve system. 64 Erection, hydraulic testing & commissioning of complete mulsifyre system by installation of high velocity water spraying & fire detection system on 63 MVA 132/33 KV TF by using old dismantled/newly laid additional pipe lines including providing of new gaskets/packings of required sizes along with necessary welding / jointing and earthing of pipe supports after re-construction of damaged RCC foundation for pipe supports. 65 Painting of above installed water spraying & fire detection system on 63 MVA 132/33 KV TF in 02 coats of synthetic enamel paint after due application of 01 coat of red oxide primer after removal of old paint by rubbing with emery paper. The water pipe lines shall be painted in P.O. red color , Air pipe lines in sky blue color,Pipe supports in black color, earthing strips in Bus green color. 66 Following works including Providing of materials are to be carried out at 220 KV S/S Kursi Road Lucknow for Proper Lighting arrangement along the 160 MVA Transformer bay and other crucial places in switchyard with all cost of men, materials ,T&P etc . Except Cables Which shall be Provided by the Department as per direction of Supervising Engineer . 67 Providing of Lighting Junction Box of size of 280 mm x 150 mm made of 16 SWG M.S. B.P. Sheet & Painted with smoke Grey colour synthetic enamel Paint, duly fitted with 1 No 6 Amp. S.P. M.C.B. on Anodised M.S. Channel ,1 No Bakelite Fuse Fitting with 6 Amp. ,Capacity NS 6 type HRC Fuse,01 No . Copper Neutral Link ,Bakelite terminal strip of 4 Nos. terminals,Cable Glands suitable for 2C /4C x 2.5 Sq. mm size incoming /outgoingControl cable etc.& fixing on the GI Structure at designated height with the help of suitable duly fabricated M.S. Bracket Clamps and Due earthung of the Junction Box including Cable Terminations. 68 Providing & Fixing of G.I. S.L. Pole Bracket duly made of 40 mm dia B class 1.20 Meter long M.S. Pipe of (ID 35 mm& OD 40 mm) and bent at one end by quarter circle in 1.0 mtr. At an angle of 30 deg for fixing of 150 watt LED street Light Luminaries Fittings with the help of MS Bracket Clamps of suitable size for fixing on G.I. column structure at designated place. 69 Provinding & Fixing of 150 Watt LED Street Light Luminaries Fittings of PHILIPS/ CROMPTON / HAVELLS/ BAJAJ Make in Single Piece die cast aliminium Alloy Housing with Pot Optics Reflector & Toughed Clear Glass Cover with Frame for Lamp Compartment including Cable Termination . 70 Cable laying & Termination- 71 Laying of following size PVC insulated Copper Control cable from LT ACDB Cubical to Various Junction Boxes below ground level in PVC Conduit pipe (Provided by the contractor ) after due excavation ,back filling etc. including all labour ,PVC Pipe etc. required for proper completion of the work . 72 2 C x 2.5 Sq mm 73 Laying of Control cables between LT Lightinig Junction box & LED Street Light Fittings along GI Structure including necessary clamping with suitable M.S. street clamp with Proper Dressing . 74 Providing & fixing of Post Lamp Glow Light of latest design complete with white color defuser suitable for installation at main entrance/garden/lawn lighting. 75 Fabrication of protective net for radiators of 132/33 KV Transformers, control room glass window, JE room glass window and associated works: 76 Providing, fabrication and fixing of protection net in front of radiator of Trasformer, made of MS channel, angle, mesh and cross section type net. Size of protection net , including all cost of men and material- 77 132/33 KV 100 MVA Transformer M/s Atlanta make, size 2500x5000 sq mm for radiator and 6100x2500 sq mm for marshalling box (total area 27.75 sq mtr) 78 132/33 KV 63 MVA Transformer M/s Atlanta make, size 6000x2500 sq mtr for radiator 79 JE Room glass window 80 Control room glass window 81 Providing, fabrication and grouting of MS Channelin front of radiator by concreting for support of protection net by welding or nut & bolt as required , including all cost of men and material: 82 132/33 KV 100 MVA Transformer M/s Atlanta make, 4500 mm size at 4 places ( Total length 18 mtr ) 83 132/33 KV 63 MVA Transformer M/s Atlanta make, 4500 mm size at 2 places ( Total length 9 mtr) 84 JE Room glass window, 3000 mm size at 2 places ( total length 6 mtr) 85 Control room glass window , 3000 mm size at 4 places ( Total length 12 mtr) 86 Fabrication and fixing of 03 no. P.I. on the top of front protection for extra support of LV side conductor including all cost of men & material: 87 132/33 KV 100 MVA Transformer M/s Atlanta make 88 132/33 KV 63 MVA Transformer M/s Atlanta make 89 Spray/ brush Painting of following equipments/items painting includes one coat of red oxide and two coats of Green/Red colour good quality Asian/Burger/Nerolac make paint after through rubbing and cleaning of old scale of painted surface to remove rust,dust etc. 90 Earthing strip 75 x 10 mm in green Colour 91 Earthing strip 50 x 06 mm in green Colour 92 Switchyard lighting JB in smoke grey color 93 220KV CT/CVT in smoke grey color 94 220KV SF6 CB in smoke grey color 95 220KV & 132KV Isolator operating box in smoke grey color 96 132KV CT/CVT in smoke grey color 97 33 KV Isolator Operating Box in smoke grey colour. 98 33 KV CT & PT Junction Box in smoke grey colour. 99 Work and supply related to work of installation of CCTV camera at crucial places of substation for protection from theft and surveillance of store and switchyard equipment 100 Providing and fixing of outdoor Static (Bullet)IP 2MPCCTV Network camera having resolution 1920x1080,full HD 1080p video, 140 dB, WDR ,3d DNR smart heater ,Image sensor 1/2.8, progressive Scan CMOS,Shutter time 1/100000 Sec. Day and Night IR cut filter with auto Switch weather proof IP 67 protection,IR range 100-120 Meter Model No DS-2CD4A25FWDIZ(H)(S) of Hikvision make or equivalent model of BOSCH/CAME make. 101 Providing and fixing of Full HDoutdoor Dome IP 2MPCCTV camera having resolution 1920x1080,full HD 1080p video, digital WDR ,3d DNR smart heater ,Image sensor 1/2.8, progressive Scan CMOS,Day and Night IR cut filter with auto Switch weather proof IP 67 protection,IR range 50-70 Meter Model No DS-2CD432F-I(Z)(H)(S) of Hikvision make or equivalent model of BOSCH/CAME make. 102 Providing and fixing of 16 Channel Embedded plug and play NVR having 16 channel,2TB HD, SupportH.264+& h.264, 6 MP ,Integrated 16 Port PoE, HDMI, resolution 1920x1080p upto 2 SATA Interface, Model No7614NI-E2/16P of Hikvision make or equivalent model of BOSCH/CAME make. 103 Providing and Fixing of 32 Full HD LED TV (model No KDL-32W700B 80cm) of Sony make 104 Supply and fixxing of 3KVA on -Line UPS with isolation transformersuitable for single phaseAC power supply and single phase outputAC ,floor mounted type with 120 minut power backup APC make (modal No.SURTD3000XLI) or equivalent modelof standerd make. 105 Providing & fixing of 4TB Hard Disk of seagate make for storing the servilance data. 106 Providing & fixing of power supply board 24 Volt DC/24Amp AC of standard make. 107 Porviding & fixing of Power Over Eathernet (POE) Switch (08 Port), 10/1000 MBPS of D-Link make model No. DGS-1210-10P (08 Port) 10/100/1000 MBPS 108 Providing & laying 40 mm dia size HDPE pipe of standard make for laying of power supply cable/OFC/CAT-6 Data cable as per requirement. 109 Providing & laying of RG-60 3 GHZ Co-axial optical fiber cable of Fonolex/Standard make for CCTV wiring. 110 Providing & laying of Cat-6 Data Cable of D-link make for connecting PTZ Cameras to NVR. 111 Providing & laying of 3 Core 1.5 Sq. mm Multi Strnad Copper Wire Power Cable of Finolex/Standard make as per IS alongwith providing & fixing of Junction Boxes whereever required. 112 Providing of Computer Table of Godrej make as per sample. 113 Earthing of Cameras & NVR as per technical specification (01 Job each) 114 Work related to supply & installation of Fire Detection System operating on the basis of feedback by Smoke Detectors in BCUs, Store, ACDB room, Battery room, & office building at 220 KV substation Kursi Road Lucknow 115 Supply & installation of 08-12 Zone Conventional fire detection and fire alarm system with power supply arrangement. (Make compatible with IS: 2189:1999 tested by ERTL (N) and System Sensor (Agni suraksha/ Agni devices/ daksh OR equivalent). 116 Supply & installation of Manual Call Point A breakable glass cover fixed in such a way that the actuating push button is kept depressed as long as the glass is intact and released when the glass is broken. A small steel hammer shall be attached to the assembly with a steel chain to facilitate breaking of glass. The manual call points shall be suitable for surface or fully / partly recessed mounting. 5mm high red painting/printed word IN CASE OF FIRE BREAK GLASS shall be provided on the front face. The manual call point shall be compatible with all conventional control panels. (Make Agni Suraksha (ASES) / Safeway Equivalent Agni Devices). 117 Electronic hooter 11 dB/24V DC with strobe (ABS-V) The enclosure should be 1.5 mm thickness duly painted and marked FIRE ALARM. All hooters shall produce a similar sound and shall maintain the same during their operation. (Make Agni Suraksha (ASES) / Safeway Equivalent/ Agni Devices). 118 Providing & Fixing of lonisation type Smoke Detectors The detector while sensitive to all type of smokes will be insensitive to ambient lights, air drafts, and changes within the operating temperature and voltage ranges. The Detector shall meet the requirements of either EN 54/ FM/ UL or LPC and shall be specifically approved by FM/ UL/LPCB. Apollo / System Sensor /Edward/Bosch. 119 Providing & Fixing of Heat Detectors (for the area like Battery room, AC plant area, DG room, etc) It is a combination of rate of rise and fixed temperature principle using thermistor and with automatic compensation for changes of ambient conditions. The thermal detectors are tested and approved to EN54 part 5 (2000) Class A1R Apollo / System Sensor / Edward / Bosch/Agni suraksha. 120 Providing & Fixing of Response Indicator Lamp assembly consisting of lamp holder and lamp shall be suitable for mounting on walls, partition etc. The housing shall be suitable for surface/flush mounting of 1.5mm thick sheet steel and the facia 3mm acrylic mounted outside a cabin, and directly connected to the detector inside the cabin. In normal circumstances the lamp should flicker but in the event the detector inside the cabin senses a fire, the lamp should glow. 121 Supply and laying 2x1.5sqmm PVC insulated and sheathed stranded copper wire. Wiring for fire alarm system in general shall comply with IS: 2189 and IS: 732 amended up to date. The detectors shall be wired by ISI marked 1.5 sq mm PVC insulated stranded FRLS copper conductor wires of 1100 volts grade as required and desired on site. Crimping type of lugs are also included in the rates of laying wires and its connections.PVC insulated copper conductor wires shall confirm to IS: 694. And, PVC insulated copper conductor armoured cables should confirm to IS: 1554 (part-1). Make National/Plaza/Kalinga or any other standard make 122 Supply and laying 4x1.5sqmm PVC insulated and sheathed stranded copper wire. Wiring for fire alarm system in general shall comply with IS: 2189 and IS: 732 amended up to date. The detectors shall be wired by ISI marked 1.5 sq mm PVC insulated stranded FRLS copper conductor wires of 1100 volts grade as required and desired on site. Crimping type of lugs are also included in the rates of laying wires and its connections. Make National/Plaza/Kalinga or any other standard make 123 Supply and installation of SMF Batteries with suitable rating as required for 24 Hours backup from Exide / Standard / Amco Prestolite/any other standard make. 124 Signage with backlit facility for Control building marking for various Fire / emergency exit points. 125 Supply and laying of Ms/PVC conduit pipe 25mm as per Requirement of site. 126 Provising, fixing & installation of different types of boards i.e. Glow Sign Board, Shutdown Notice Board, Instruction Board etc as detailed bwlow, to be carried out at 220KV substation Kursi Road Lucknow as per specifications and directions of supervising engineer: 127 Providing, fixing and installation of Glow Sign Board of size 10 ft x 6 ft for substation single line diagram to be fixed in control room building of the substtaion. The Glow Sign Board should be illuminated using sufficient number of LED tube lights. The board shall be made of ACrilic sheet and shall be provided with back support frame & fixing arrangement. 128 Name plates made of 2mm thick Aluminium Sheet coveredwith 3 M HIP retro reflective sheet of following size with details / name written by 3M HIP Retro reflective sheet as per prescribed color scheme to be fixed with the help of nuts & bolts at already installed equipment structure in switchyardwith all cost of plates, nut-bolts, misc materials, T&Pand labour as per specificatins & directions of supervising engineer: 129 300mm x200mm 130 450mm x 250mm 131 500mm x 250mm 132 R,Y,B phase plate sets consisting of one plate of red,, yellow, blue colors in each set & plates of dia 250mm duly made of 2mm thick aluminium sheet with face to be fully covered in red , yellow, blue phase colors in 3 M HIP retro reflective sheetand the phase plate set to be fixed with the help of suitable size G.I. bolts, nuts on already installed equipment structure etc at the substation.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
6.
Health and Family Welfare #10551414 Price Bid
Tender For Electrification Work In Phc Building At Palasani District Jodhpur - Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 2.0 TR ISEER not less then 3.8 81 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 82 25 mm 83 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 84 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 85 150 mm dia per running inch length 86 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 87 4 kVA 88 5 kVA 89 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 90 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Surface Mounting (with extruded alumn. Housing ) 92 Minimum lumen output 1950 lm 93 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 95 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 4 kg 97 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 15 Ltr. 99 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 2 pair 101 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 102 10 Pairs 103 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 104 RJ-11 telephone jack singleline 105 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 106 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Cat 6, Un-sheilded Information Outlet 108 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 Single Aperture 110 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 112 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 Modular Patch Panel Loaded with Cat -6 I/O 114 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 115 24 Port 116 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 117 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 118 Recessed Mounting 119 Minimum lumen output 4200 lm 120 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 121 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 122 1 Mtr 123 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 3.5 x 25.0 sq.mm 125 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 126 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 127 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 128 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 130 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 131 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 132 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 133 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 134 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 135 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 136 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 137 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 138 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 139 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 140 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 141 Ring type tape wound CT 142 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 143 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Red/yellow/Green colour 145 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 146 Electrolytic grade Aluminium bus bar 6010 grade 147 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protectionwith ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA,provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 148 Two pole 100/300mA sensitivity 149 40 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
7.
Health and Family Welfare #10551411 Price Bid
Tender For Electrification Work In Phc Building At Rajlani District Jodhpur - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 2.0 TR ISEER not less then 3.8 81 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 82 25 mm 83 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 84 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 85 150 mm dia per running inch length 86 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 87 4 kVA 88 5 kVA 89 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 90 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Surface Mounting (with extruded alumn. Housing ) 92 Minimum lumen output 1950 lm 93 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 95 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 4 kg 97 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 15 Ltr. 99 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 2 pair 101 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 102 10 Pairs 103 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 104 RJ-11 telephone jack singleline 105 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 106 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Cat 6, Un-sheilded Information Outlet 108 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 Single Aperture 110 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 112 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 Modular Patch Panel Loaded with Cat -6 I/O 114 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 115 24 Port 116 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 117 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 118 Recessed Mounting 119 Minimum lumen output 4200 lm 120 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 121 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 122 1 Mtr 123 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 3.5 x 25.0 sq.mm 125 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 126 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 127 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 128 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 130 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 131 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 132 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 133 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 134 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 135 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 136 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 137 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 138 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 139 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 140 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 141 Ring type tape wound CT 142 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 143 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Red/yellow/Green colour 145 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 146 Electrolytic grade Aluminium bus bar 6010 grade 147 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protectionwith ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA,provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 148 Two pole 100/300mA sensitivity 149 40 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
8.
Health and Family Welfare #10551402 Price Bid
Tender For Electrification Work In Bphu And Bphl At Chc Setrawa Block Dechu District Phalodi - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 11 20 mm 12 25 mm 13 32 mm 14 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 2 x 2.5 sq. mm. + 1x1.5sqmm 16 1 x 4.0 sq.mm 17 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 18 4 x 6.0 sq.mm 19 4 x 10.0 sq.mm 20 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 21 1.2 mm thickG Iboxes 22 100mm x 100mm x 60mm 23 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 3.0 mm thick 25 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 26 75 mm dia 27 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 Single pole MCB (With B/C curve tripping Characteristics) 30 6 A to 32 A rating 31 Four pole MCB (With B/C curve tripping Characteristics) 32 50/63 A rating 33 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 34 Metal door (Three phase) IK-09 and IP-43with Metal end box 35 8 Way 36 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 37 Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box 38 4 Way 39 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure A attached with this BSR 42 IP -67 Surface/Wall mounted socket 43 32 A 3 pin(2P+E) 44 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 45 5 step fan regulator 2 Module 360 dgree rotating 46 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 47 4 pole MCCB With Thermal Magnetic release 48 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 49 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 50 50.0 Sq. mm 51 3.5 core 52 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 53 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 54 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 55 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 56 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 57 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 58 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 59 17.2 mm thick and 3 Mtr. Long 60 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 25mm x 3mm Alum. Strip 62 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) 64 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 300 mm sweep(900/1400 RPM) 66 380 mm sweep(900/1400 RPM) 67 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 Up to 380 mm size 69 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 70 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 71 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 72 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 Surface Mounting (with extruded alumn. Housing ) 74 Minimum lumen output 2400 lm 75 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 LED Street Light fixture with Minimum lumen output 8700 lm 77 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 32 mm Dia. 79 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 Cat 6, Un-sheilded Information Outlet 82 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Single Aperture 84 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 86 2 Mtr 87 Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic,should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 12 Ports 90 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.5 TR ISEER not less then 3.8 93 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kVA 95 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 96 100 mm dia per running inch length 97 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 20 mm 99 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 101 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
9.
Road Transport and Highways #10447437 Price Bid
Tender For Sale Of Condemn Scraps & Obselete Drinking Water Machineries, Raw Materials And Consumables Etc., - 04 2023--- 1 New Self motor pinion bush scraps as its condition at central workshop,Trichy 2 NewSelf motor Front bush scraps as its condition at central workshop,Trichy 3 New Auto electrical spares as its condition at central workshop,Trichy 4 New Auto engine spares, gear box spares as its condition at central workshop,Trichy 5 New Rubber, Plastic spares as its condition at central workshop,Trichy 6 Condemned iron dust scraps as its condition at central workshop,Trichy 7 Condemned plywood and fire woodscrapsas its condition (Approx. 4000Kgs) at central workshop,Trichy 8 Condemned teak wood pieces scrapsas its condition ( Approx. 1500 Kgs) 9 NewEngine Oil filter - 401 Leyland Engine scraps as its condition at central workshop,Trichy 10 New bolt, screw,alu cups and rivitsas its condition at central workshop,Trichy 11 Condemned Auto Aluminium scraps as its condition at central workshop,Trichy 12 Condemnedcopper radiatorassembly scraps as its condition -(Approx. 15kg copper& 18kg iron/No)at central workshop,Trichy 13 Condemned Aluminium radiator core and intercooler scraps as its condition at central workshop,Trichy 14 Condemned Plastic and fibre scraps as its condition (Approx.750kg) at central workshop,Trichy 15 Condemned damaged wheel disc scraps as its condition at central workshop,Trichy 16 Condemned Piston rings ,connect rod bearing and connecting rod bush scraps as its condition at central workshop,Trichy 17 Condemned seat piston and dickey door piston scraps as its condition at central workshop,Trichy 18 Condemned empty Plastic barrel 210ltr capacity scraps as its condition at central workshop,Trichy 19 Condemned automizer pipe scraps as its condition at central workshop,Trichy 20 Condemned seat frame assembly scraps 17 nos asits condition at central workshop,Trichy 21 Condemned Empty Tin container scraps as its condition(1ltr, 4ltr, 20ltr) at central workshop,Trichy 22 Condemned front axle 1 no, rear axle 1 noscraps as its condition ( Approx 310 Kg ) at central workshop,Trichy 23 Condemnedtypewritterscraps as its condition at central workshop,Trichy 24 Condemned fan clutch scraps as its condition at central workshop,Trichy 25 Condemned under chassisiron spares scraps ( air tank, air filter doom,silencer doom,silencer pipe, radiator bracket, radiator top tank, all U/C brackets,track rods,suspension linkages,gear joint,cross bar, steering universal & other suspension spares ) as its condition at central workshop,Trichy 26 Condemned Selfmotor and alternator spares scraps as its condition at central workshop,Trichy 27 Condemned Plastic AC blower motor scraps as its condition(Copper approx 100g per no) at central workshop,Trichy 28 Condemned Bearing and cone scraps as its condition at central workshop,Trichy 29 Condemned GI cutting scrapsas its condition at central workshop,Trichy 30 Condemned MS cutting scrapsas its condition at central workshop,Trichy 31 Condemned push back seat frame assembly scrapsasits condition at central workshop,Trichy 32 CondemnedAuto scrapsas its condition (air filter, diesel filter, strainer, engine oil filter, rubber bed and oil seals, air bellow, engine bed, brake lining , rubber hoses) - Approx5000kg at central workshop,Trichy 33 Condemned Wheel disc and rings scraps as its condition at central workshop,Trichy 34 Condemned brake drum scraps as its condition at central workshop,Trichy 35 Condemned slack adjuster sparesscraps as its condition at central workshop,Trichy 36 Condemned Gear box spares and Gear wheel scraps as its condition at central workshop,Trichy 37 Condemned water pump shaft with bearing scraps as its condition at central workshop,Trichy 38 Condemned damaged, dented and corroded barrel scraps as its condition at central workshop,Trichy 39 Condemned battery cable (copper) scraps as its condition at central workshop,Trichy 40 Condemned clutch finger and withdrawal facing scraps as its condition at central workshop,Trichy 41 Condemned air balloon assembly scraps as its condition at central workshop,Trichy 42 Condemned Open Empty Grease barrel with lid scraps as its conditionat central workshop,Trichy 43 Condemned BSIII-A engine assembly without selfmotor and alternator scraps as its condition(Approx. 540 kg/no)at central workshop,Trichy 44 Condemned ZF Gear box assembly scraps as its condition (Approx. 117kg/no.) at central workshop,Trichy 45 Condemned Joint assembly scraps as its condition at central workshop,Trichy 46 Condemned Waste paper scraps as its condition at central workshop,Trichy 47 Condemned Auto iron spares scraps as its condition at central workshop,Trichy 48 Condemned clutch disc scraps as its condition at central workshop,Trichy 49 Condemned engine liner scraps as its condition at central workshop,Trichy 50 Condemned self motor assembly scraps as its condition((Approx. copper 2 Kg, Alu 1.5 Kg, iron 8Kg) /no.) at central workshop,Trichy 51 Condemned clutch spring and valve spring scraps as its conditionat central workshop,Trichy 52 Condemned shock absorber scraps as its condition at central workshop,Trichy 53 Condemned light vehicle brake drum and brake disc(cast iron) scraps as its conditionat central workshop,Trichy 54 Condemned Tata Cover Assembly scraps as its condition(Approx. 20 kg/no)at central workshop,Trichy 55 Condemned spherilastic bush scraps as its condition at central workshop,Trichy 56 Condemned bus side window frame with glass scraps as its condition(Approx.3kg aluminium,8kg glass/no) at central workshop,Trichy 57 CondemnedTube with brass mouth scrapsas its condition at central workshop,Trichy 58 Condemned tube cut pieces scraps as its condition at central workshop,Trichy 59 Condemned empty30ltr capacity Tin scraps as its condition at central workshop,Trichy 60 Condemnedbuffing dustscraps as its condition at central workshop,Trichy 61 Condemned 10x20 flap scraps as its condition at central workshop,Trichy 62 Condemned flap cut pieces scraps as its condition at central workshop,Trichy 63 Condemned thread rubber cut pieces scraps as its condition at central workshop,Trichy 64 Condemned B grade Tubeless Tyresas its condition at central workshop,Trichy 65 Condemned B grade Tubeless Tyresas its condition at central workshop,Trichy 66 Condemned B grade Tubeless Tyresas its condition at central workshop,Trichy 67 Condemned10x20 B grade Radial Rt Tyresas its condition at central workshop,Trichy 68 Condemned tubeless 10x20 C grade RT Tyres as its condition at central workshop,Trichy 69 Condemned original tubeless 10x20 tyres as its condition at central workshop,Trichy 70 Condemned 12V 21 plate light weight Battery scraps as its condition at central workshop,Trichy 71 Condemned 12V 25 plate light weight Battery scraps as its condition at central workshop,Trichy 72 Condemned old used engine oil with Metal barrel 210 ltr capacity scraps as its conditionat central workshop,Trichy 73 Condemned old used engine oil with Plastic barrel 210 ltr capacity scraps as its conditionat central workshop,Trichy 74 Condemned Old used Grease with barrel 182 kg capacity as scraps as its condition at central workshop,Trichy 75 Blowing Machine at IRT,Gummidipoondi,Chennai 76 Conveyor Motor (BLOWING TO RFC) at IRT,Gummidipoondi,Chennai 77 Chiller Machine at IRT,Gummidipoondi,Chennai 78 Cooling Tower without motor at IRT,Gummidipoondi,Chennai 79 Low Pressure Compressor at IRT,Gummidipoondi,Chennai 80 Low Pressure Compressor with Air Receiver and Air Dryer at IRT,Gummidipoondi,Chennai 81 High Pressure Compressor with Air Receiver and Air Dryer at IRT,Gummidipoondi,Chennai 82 Rinsing, Filling and Capping Machine at IRT,Gummidipoondi,Chennai 83 DOMINO PRINTER at IRT,Gummidipoondi,Chennai 84 BOPP LABEL MACHINE at IRT,Gummidipoondi,Chennai 85 Palletts at IRT,Gummidipoondi,Chennai 86 LABORATORY INSTRUMENTS WITH FOLLOWING ACCESSORIES ( Analytical Balance , Digital PH Meter, Digital PH Meter - II, Digital TDS meter - 2 nos, Digital Nephelometer , Digital Spectrophotometer, Magnetic stirrer with hot plate, Hot plate, Heating Mandle & kjeldhal apparatus,Heating Mandle & kjeldhal apparatus, Water Bath, Gas stripping apparatus, B.O.D Incubator -I (22° C), B.O.D Incubator -II(25° C), Ordinary Microscope, Incubator - I (37° C), Incubator - II (37° C), Digital colony counter, UV Dark chamber,Hot Air Oven, Laminar air flow unit,Vacuum Pump ,Gas cylinder small ,Autoclave ) at IRT,Gummidipoondi,Chennai 87 Pallet Rack (3 Rows) at IRT,Gummidipoondi,Chennai 88 CAP at IRT,Gummidipoondi,Chennai 89 BOPP LABLE at IRT,Gummidipoondi,Chennai 90 INK at IRT,Gummidipoondi,Chennai 91 MAKE UP at IRT,Gummidipoondi,Chennai 92 WASH SOLUTION at IRT,Gummidipoondi,Chennai 93 SODIUM CARBONATE at IRT,Gummidipoondi,Chennai 94 SODIUM HYDROXIDE PELLETS at IRT,Gummidipoondi,Chennai 95 PLEATED PP EFFICIENCY CART-30-0.2MM DOE FILTER at IRT,Gummidipoondi,Chennai 96 PLEATED PP EFFICIENCY CART-30-0.45MM DOE FILTER at IRT,Gummidipoondi,Chennai 97 SP 40 (SPUN-5 MICRON) at IRT,Gummidipoondi,Chennai 98 BAG FILTER at IRT,Gummidipoondi,Chennai 99 BRACKET-12000-3-0763 at IRT,Gummidipoondi,Chennai 100 FINGER SPRING-12000-1-1731 at IRT,Gummidipoondi,Chennai 101 PULL DUWN BLOCK BUSH-12000-1-1731 at IRT,Gummidipoondi,Chennai 102 STANDARD RACK at IRT,Gummidipoondi,Chennai 103 Ball bearing (insert) Yar206 (SKF)0BGYSR2062F at IRT,Gummidipoondi,Chennai 104 Blow pin 109S14ST1202 at IRT,Gummidipoondi,Chennai 105 Square Shaft-Actuator Tie Bar09S24TO0602 at IRT,Gummidipoondi,Chennai 106 COOLING FAN ROUND 8 ROUND at IRT,Gummidipoondi,Chennai 107 NYLON ENDLESS BELT at IRT,Gummidipoondi,Chennai 108 QUICK EXHAUST VALVE -G1/4 (SILENCER TYPE) at IRT,Gummidipoondi,Chennai 109 LABLE DRUM SPRING-4017-005 at IRT,Gummidipoondi,Chennai 110 TEMPERATURE CONTROLLER(SELEC)-TC 544 at IRT,Gummidipoondi,Chennai 111 LABLE SENSOR at IRT,Gummidipoondi,Chennai 112 PUSHER PAD 1 LTR GREEN at IRT,Gummidipoondi,Chennai 113 (163432) DNC - 80 - 75 - PPV - Aat IRT,Gummidipoondi,Chennai 114 (156620 ) ADVU - 32 - 25 - A- P- A at IRT,Gummidipoondi,Chennai 115 (163304) DNC - 32 - 55 - PPV -A at IRT,Gummidipoondi,Chennai 116 (163304) DNC - 32 - 600 - PPV -A at IRT,Gummidipoondi,Chennai 117 FLOW CONTROL VALVE 1/8*DIA6 at IRT,Gummidipoondi,Chennai 118 FLOW CONTROL VALVE 1/8*DIA8 at IRT,Gummidipoondi,Chennai 119 STEER WHEEL TANDEM PU (MH 26000116) at IRT,Gummidipoondi,Chennai 120 LOAD ROLLER TANDEM PU (MH 26000221) at IRT,Gummidipoondi,Chennai 121 ELASTIC PIN (MH 26000216) at IRT,Gummidipoondi,Chennai 122 BALL BRG (MH 54007310) at IRT,Gummidipoondi,Chennai 123 (MH02102159)BULL P RETAINER CAP G100 at IRT,Gummidipoondi,Chennai 124 HORN BUTTON KIT (MH02105671) at IRT,Gummidipoondi,Chennai 125 SWITCH (MH02292630) at IRT,Gummidipoondi,Chennai 126 CONTACTOR SE-80-36V(MH71700006) at IRT,Gummidipoondi,Chennai 127 CONTROL CKT(MH71700032) at IRT,Gummidipoondi,Chennai 128 KIT LINED SHOE (MH02511890) at IRT,Gummidipoondi,Chennai 129 SPRING IT ELEC (MH02112402) at IRT,Gummidipoondi,Chennai 130 DRIVE FLANGE (MH-02511746) at IRT,Gummidipoondi,Chennai 131 HEADLAMP ASSLY (MH-71500763) at IRT,Gummidipoondi,Chennai 132 HEX BOLT HT IS 1364 M8*20MM(MH49251205) at IRT,Gummidipoondi,Chennai 133 SPRING WASHER MS IS 3063 M8(MH53130149) at IRT,Gummidipoondi,Chennai 134 PLAIN WASHER MS IS 2016 M8 (MH53110316) at IRT,Gummidipoondi,Chennai 135 PRC COMP PL SHEAVE ASSEMBLY MS(MH02467386) at IRT,Gummidipoondi,Chennai 136 PRC COMP PL SHEAVE ASSEMBLY MS(MH02467399) at IRT,Gummidipoondi,Chennai 137 SEAL RAWHIDE (MH02109330) at IRT,Gummidipoondi,Chennai 138 ELECTRICAL BDI CURTIS 803(MH 71500177) at IRT,Gummidipoondi,Chennai 139 P CRSS BR 19MM 15MM (MH 02570688) at IRT,Gummidipoondi,Chennai 140 KIT SET OF LINED SHOE G100E(MH 02570097) at IRT,Gummidipoondi,Chennai 141 BALL BEARING 6001 at IRT,Gummidipoondi,Chennai 142 BALL BEARING 6005at IRT,Gummidipoondi,Chennai 143 BALL BEARING 6006 at IRT,Gummidipoondi,Chennai 144 6010 BEARING(SKF) at IRT,Gummidipoondi,Chennai 145 HOSE (6245570800) at IRT,Gummidipoondi,Chennai 146 HOSE (6245579700) at IRT,Gummidipoondi,Chennai 147 HOSE (6245566100) at IRT,Gummidipoondi,Chennai 148 HOSE (6245578500) at IRT,Gummidipoondi,Chennai 149 HOSE (6245578600) at IRT,Gummidipoondi,Chennai 150 1903074508 (1903105408) GASKET at IRT,Gummidipoondi,Chennai 151 1903105508 GASKET at IRT,Gummidipoondi,Chennai 152 Temp Sensor(1089057470) at IRT,Gummidipoondi,Chennai 153 RIDER RING D 160(1903395208) at IRT,Gummidipoondi,Chennai 154 RIDER RING D 85 at IRT,Gummidipoondi,Chennai
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 24
10.
Health and Family Welfare #10433257 Price Bid
Supply Of Machine, Equipment And Others , List Of Machine And Equipments , Laproscopic Hd Camera Brand - Karl Storz/Conmed/Olympus Technical Specification Resolution: 1920X1200 Pixes / 1900X1000 Pixes Cable Length: 300 Cm , Ultrasonic Harmonic Scalpel Brand - Johnson Technical Specification Dimensions: (Hxwxd) 5.3 14.5X15.2 Voltage: 100-240 Vac Frequency: 50/60 Hz Rated Current: 3 Amp , Ultrasonic Harmonic Scalpel Brand - Valley Lab Technical Specification Macrobipolar/Bipolar: 473 Khz Sinusoid, 100% Duty Cycle. Seal: 473 Khz Sinusoid Pulsed , Hand Instruments For Laproscopy Brand- Karl Storz/ Olympus Technical Specification I) Veress Needle: It Should Be With Spring Action Blunt Style -12 Cm: 1 No 10 Cm: 1 No 8 Cm: 1 No Ii) Trocar And Cannula:10 Mm: 2 Nos 7 Mm: 1 No. 5 Mm 6 Nos It Should Consists Of Trocar, Cannula With Insufflation And Multifunctional Valve And Must Have Pyramidal Tip. Iii) Reducer/Reduction Sleeve 5 Mm. 1 No Iv) Telescopes: 10 Mm- 0°- 1 Nos -30? - 1 Nos5 Mm-30? 1 Nos Rigid Rod Lens System Provides Good Resolution And The Better Dept Perception. It Should Have Uniform Image Brightness And Autoclavable. The 300 Forward Oblique Angle And Permits For Greater Latitude For Viewing Underlying Areas Under Difficult Anatomical Conditions. V) Suction Cannula: 10 Mm - 1 No 5 Mm -1 Nos Vi) Laparoscopic Scissors: Curved (Monopolar Metzenbaum Dissector 5Mm Diameter): 1 Nos Straight (Bipolar):1 Nosperitoneal Scissor: 1 Nosvii) Unipolar Forceps (Hook & Spatula): 2 Nos Viii) Bipolar Forceps : 2 Nos Ix) Atraumatic Forceps: Maryland Dissector Forceps: : 2 Nos. Fenestrated Forceps: : 2 Nos. X) Needle Holder (Flat Jaw) With Handle : 2Nos Xi) Monopolar Cable (Reusable):1 Nos. Xii) Bipolar Cable (Reusable): 1 Nos Xiii) Allis (Double Row Of Teeth) Grasper: 1 Nosxiv) Aspiration Needle: 1 Nos. Xv) Reducer/ Reduction Sleeve (5Mm): 1 Nos Xvi) Grasping Forceps (Toothed & Rachet 5Mm): 2 Nos Xvii) Laparoscopic Knot Pusher: 1 Nos Xviii) Clip Applicator (Reusable): 5Mm -: 1 Nos : 10 Mm: Ino Xix) Uterine Manipulator: 1 Nos Xx) Clips( Medium & Large) Xxi) Drilling Needle:1 Nos Xxii) Infiltration Needle: 1 Nos Xxiii) Biopsy Forceps (Toothed Punch Biopsy): 1 Nos Xxiv) Myoma Fixation Screw: 2 Nos Xxv) Tissue Morcellator With Base Unit & Accessories: 1 Nos , Dual Wavelenght Laser Brand- Zeiss Technical Specification Laser Type: Diode, Semiconductor Wavelength : 1470Nm+635Nm Max Power: 15 Watts/1470Nm+5Mv/635 Aiming Beam : 635Nm/1, 4Mw Max Or 515Nm/2, 5Mw Max Operation Mode : Continuous Or Modulated Pulsed Time : 0.05Ms-1000Ms Beam Delivery : Sma905 Connector Optic Fiber Compatible : Optic Fibers Having A Core From 200Um To 1000Um, Na=0.22~0.48 Beam Emission Initiation : Footswitch Controller :Microprocessor Display : 10.1 Ips With Touch Panel Medical Approved Cooling :Internal, Air And Thermoelectric Cooling Power Supply Of The Laser: Dc 24V/8.33A From The Separate Ac Power Supply Of Ac Adapter : Single Phase 100-240Va; 50-60Hz, Max 90W Ac Adapterdc 24V/8.33A Medical Approved Laser Dimensions: 27Cm*24,5Cm X 9Cm Laser Weight: 2.75Kg Laser Case Dimensions : 53Cm X 38Cm X 23Cm Weight Of Laser With Cases : 9Kg Environmental Conditions During Work : From +10 To 24°C Degree, Relative Humidity From 30% Up To 60% Cass Of Medical Deviceiib Laser Safety Class 4 Electric Safety Class I Type B Housing Protection Degree Ip20b , Hd Camera Set Brand- Karl Storz/ Olympus Technical Specification (I) Hopkinsa® Forward-Oblique Telescope 30A, Diameter 4 Mm, Length 30 Cm, A Utoclavable, Fiber Optic Light Transmission Incorporated, Color Code Ed :1 Nos (Ii) Telecam C3 : 1 Nos (Iii) Image1 St™ Hx One-Chip Full Hd Camera Head, 50/60 Hz, Fixed Focus, Prog Ressive Scan, Soakable, Gas-And Plasmasterilizable, Focal Length F = 16 Mm, 2 Freely Programmable Camera Head Buttons, For Use With Image1 X-Link Tc301, Tele Pack + And Tp101 : 1 Nos (Iv) Medical Grade Surgical Monitor - Fhd : 1Nos (V) Cold Light Fountain Power Led 175 Scb, With Integrated Karl Storz-Scb, High-Performance Led And One Karl Storz Light Outlet, Power Supply 11-240 Vac, 50/60 Hz Including: 400 A Mains Cord 20090170 Scb Connecti G Cable : 1Nos (Vi) Fiber Optic Light Cable, With Straight Connector, Extremely Heat-Resi Stant, With Safety Lock, Diameter 4. 8 Mm, Length 250 Cm :1 Nos , T U R P Set Brand-Olympus Technical Specification (1) Cystoscope-Urethroscope Sheath, 22 Fr :1 Nos (2) Telescope Bridge, With 1 Lockable Channel, For Use With Cystoscope Sheaths : 1Nos (3) Working Element, E 1 Working Element (Also For Use With Optical Urethrotome) 2 Cutting Loops2 Coagulat Ng Electrodes 2 High Frequency Cords 1 Protection Tube . The Thumb Support Is Movable. In Rest Position Th Electrode Is Inside The Sheath.:1 Nos (4) Resectoscope Sheath, 26 Fr, 1 Nos (5) Schmiedt Visual Obturator, : 1 Nos (6) Cutting Loop Angled, 24/26 Fr., Units Of 6 : 1Nos Ellik Evacuator:1 Nos (7)Urethrotome Sheath, 21 Fr. Urethrotome Sheath And 2 Luer-Lock Cones.:1 Nos (8) Obturator, For Urethrotome Sheath, 21 Fr.1 Nos Sachse Cold Knife, Straight, Not To Be Used With Hf Current This Artic Le Is Only Available In Units Of 6 :1 Nos , Flexible Cystoscope Brand-Olympus Technical Specification Cysto-Urethro-Fiberscope, With Contrapositive Deflection Mechanism, De Flection Of Distal Tip 210°/140, Direction Of View 0°, Angle Of View 10, Working Channel Inner Diameter 7 Fr., Sheath Size 15.5 Fr., Worki G Length 37 ??, Consisting Of: 11272 Cu1 Cystourethro-Fiberscope 2767 A Case 27023 Fe Grasping Forceps 27023 Ze Biopsy Forceps 13242 Xl Lea Age Tester 11025 E Pressure Compensation Cap 27651 B Cleaning Brush 27 14 Y Lueradaptor , Echocardiography Brand-Ge Healthcare/ Philips / Siemens Healthcare/Bpl Technical Specification A) 2D, M-Mode, Colour M-Mode B) Colour Flow Doppler Imaging C) Fully Steerable Pulsed Doppler D) Fully Steerabie Continuous Wave Recall E) Digital Cine Replay Of All Imaging And Doppler Modalities. F) On Screen Cine Storage & Image Recall G) Digital Image Storage And Patient Archive With True Scanner Frame Rates. H) Full Measurement And Analysis Capabilities. Both On Line And Offline Preferable. I) Imaging Frequencies From 1 Mhz To 15 Mhz J) Review Of Stored Ultrasound Images. K) User Adjustable B Colorization Maps, Gain Settings, Colour Doppler Baseline, Angle Correction And Other Important Parameters With Live/Frozen/Archived Images/Loops. , 12 Lead Ecg Machine (Brand - Bpl/Maestros) Technical Specification Electrocardiograph Should Have Capability Of Recording 12-Lead Ecg And Should Have The Following Features: 1. Should Have Simultaneous Acquisition Of 12 Leads 2. Should Have A Display To Preview The Ecg Waveform Before Printing 3. Should Have 7 Inch Or More Display With High Resolution Screen 4. Should Be Compact, Portable And Easy To Operate 5. Should Have Keyboard For Manual Entry Of Patient Data 6. Should Have Provision For Providing Hospital Name On The Printed Record7. Should Work On Li-Ion Battery8. Should Have A Frequency Response Of 0.01-300 Hz 9. Should Have Sampling Frequency Of 15,000 Hz Or More10. The Device Should Weigh Less Than 5.5 Kgs With Battery11. Should Have A Special Arrhythmia Triggered Mode Of Printing12. Should Have Pacemaker Detection Facility 13. Should Be Able To Record On Different Modes Of Sensitivity: 2.5,5,10,20 Mm/Mv & Agc14. Should Have Different Recording Speeds: 5, 10, 12.5, 25 And 50 Mm/Sec15. Should Have Different Filters Available For Smoothing Of Waveform16. Should Have Ac Filter, Emg Filter: 25 Or 35 Or 45 Hz Or Off17. Should Have Anti-Drift Filter18. Should Have Different Print Formats: 3/6/12, 3X4 With Rhythm Leads, 6X2, 12X119. Should Have A Large Storage Of 700 Ecgs Or More20. In Case Of Error In Lead Connections, The Machine Should Display The Change In Color Of Particular Lead.21. Should Be Able Transfer Data Directly In Pdf Format To Usb22. Should Be Able To Printout Records On Thermal Paper As Well Z-Fold23. Should Have Facility Of Printing In Automatic/ Manual/ Rhythm/ R-R Mode Of Printing24. Should Have Facility For Interpretations And Measurements25. Should Provide Detailed Printout Of Patient Data26. Should Have Paper Of Minimum Width Of 210Mm27. Should Have The Capability To Generate Any Number Of Ecg Copies For Distribution28. Should Be Able To Connect To Pc 29. Should Be Able To Operate To A Maximum Of 4 Hours On A Newly Charged Battery30. Should Have Direct External Printer Connectivity31. The Unit Should Be Portable And Should Be Able To Carry With Help Of A Handle.32. The Product Should Be Ce Certified33. The Manufacturer Should Be Iso Certified34. The Device Should Be Provided With Standard Accessories:A) Ecg Cable (Adult)-1 Nob) Gel Bottle- 1 Noc) Chest Electrodes (Set Of 6)- 1 Nod) Limb Electrodes (Set Of 4)- 1 Noe) Z-Fold Paper - 1 Packf) User Manual-1 No , Multipara Patient Monitor(Brand - Drager/Penlon/ Bpl) Technical Specifications For Multipara Monitor 1. Multiparameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,(Massimo),Nibp (Suntech) Temperature.3. Optional Parameter Etco2, Dual Ibp, Agm 4. Should Have12-Inchcolor Lcd Display.5. Should Have Dual Modes Of Operation: Rotary Knob.6. Should Display 7 Waveforms Or More7. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen.8. Ecg: Should Be Able To Monitor Ecg Through 5-Lead Patient Cab Should Have Manual St Analysis Window ,Should Detect 20 Arrhythmias And Generate Alarms. , The Priority Of Arrhythmia Alarms Can Be Configurable, Should Measure Pvc &Pac Should Be Able To Monitor Heart Rate From 10-300 Bpm Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etcshould Have Pacemaker Detection Facility Respiration: Measurement Range Of 0 To 150 Breaths Per Minshould Have Gain Selection: ×0.25, ×1, ×2, ×4 Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S Should Have Apnea Detection Facility Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 10 Spo2: Should Have Massimo Technologyshould Have Measurement Range Of 0~100 % Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph Should Be Able To Select Sat Sec To Avoid False Alarm 11. Nibp: Must Be Of Suntech Medicaltechnology For Clinical-Grade Blood Pressure Measurement Have Auto, Manual, And Stat Modes Of Operation For Nibp. Should Have A Measuring Range Of 0-280 Mmhg Should Have 2 Channels For Temperature Monitoring Should Have Data Storage Capabilities:72 Hours Of Trend Data Storage. , Bp Machine Brand - Pagoda/ Omron/ Platinium/ Dr Trust/Bpl Technical Specification Should Be Able To Measure Blood Pressure And Pulse Rate In Adult As Well As Pediatric Patients. Should Be Based On Oscillometric Measurement Technology, Using Dynamic Linear Deflation Method. Should Have Backlight Lcd Display With Easy To View Readings In Dim Light. Pressuremeasurement Range Should Be 60 To 250Mm Hg Systolic, And 40 To 200Mm Hg Diastolic. Pressure Display Accuracy Of +/- 3 To 5 Mm Hg Pulse Rate Measurement Range Of 40 To 200 Per Minute Pulse Measurement Accuracy Of Within 5% Should Include Ac Adapter (Input Range 100-240V And Output Voltage Dc 6V), Preferably With Rechargeable Battery (3.6V To 4.8V, 1900 To 2400Mah) Cuff (22 To 32 Cm Size) Should Be Supplied With Standard Adult Size Single Button Operation For Start And Stop Functions With Auto-Inflation Of Blood Pressure Cuff. , Ventilator Brand - Drager/Bpl/Medisys Technical Specification 1. The Ventilator Should Be High-Endventilator Suitable For Ventilating To Adult And Pediatric Application. Should Have Advanced Microprocessor Control System With Individual Selection Of Various Ventilation Parameters. 2. The Unit Should Be With Altitude Compensation For Volume And Btps Correction For Monitoring3. The Unit Should Be Of Wall Independent Gas Delivery System. Demonstration Of The Equipment Is A Must Demonstration Of The Equipment Is A Must4. Should Have Facility For Invasive And Non-Invasive Ventilation;5. The Ventilator Should Have 12” Or More Lcd Screen With Touch Facility For Display Of Waveforms. Should Have Brightness Modes Like Day/Night-Mode. The Real Time Display Of All Parameters/Waveforms Should Be Clearly Visible From All Angles6. Should Have Modes Of Ventilation Equipped With Newer Modes Of Ventilation:A) Assist/ Controlb) Volume Control Modes: Vcv, Vc-Simv, Plvc) Pressure Control Modes: Pcv, Pc-Simv, Bi-Level, Bilevel-St, Pc-Aprvd) Spontaneous Ventilation Modes: Psv, Cpap, Bilevel /Similar, Bilevel St / Similare) Prvc/Pcv-Vg/Dynamic Bilevel/Or Its Equivalent Modef) Closed Looplung Protective Mode- Asv/Nava/Wobov/Alpv/Smart Care (At Least 1 Of The Mentioned Mode Is Mandatory)G) Should Have Pav (Proportional Assist Ventilation) / Pps (Proportional Pressure Support)/ Paps (Proportional Adaptive Pressure Support)H) Cpr (Resuscitation Mode),I)Niv In All Pressure Modes7. Hfot /Nasal Cpap Breathing Therapy Should Be Capable Of Adjusting The Range Up To 60Lpm8 A) Apnea Backup Ventilation In All Modes8 B) It Should Have Weaning Analyzer Tools : Sat & Sbt9. Should Have In-Built Nebulizer With Capability To Deliver Fine Particle Size Of To Be Used In Line10. Should Have Facility To Measure And Display The Following Parameters:A) Airway Pressure (Peak & Mean)B) Tidal Volume (Inspired & Expired)C) Minute Volume (Expired)D) Spontaneous Minute Volumee) Total Frequencyf) Fio2 Dynamicg) Intrinsic Peep, V Trap & Time Constant (Rcexp)H) Resistance & Compliance11. Automatic Compliance And Leakage Compensation For Circuit And Et Tube 12. Should Have Facility Of Logbook, For Events And Alarms With Date & Time 13. Should Have Following Setting & Monitored Parametersa) Tidal Volume; Pre-Set Range For Both Pediatric & Adult Modes To Be Providedb) Inspiratory Pressure (Up To 100Cm Of H2o);C) Respiratory Rate 1 To120 Bpm;D) Apnea Back Up Rate;E) Peep: 0-50 Cmh2of) Inspiratory Flow: 0-120 Lpmg) Max Peak Flow : 280 Lpm Or Betterh) O2 Concentration: 21-100%I) Pressure Support: 1-(100-Peep) Cmh20j) Fio2 Setting Range Between 21% And 100%;K) Pressure Flow & Volume Curves;L) Loop For V-Flow, Flow-P, Flow-Paw And At Least 5 Storage Spaces For Reference Loopsm) I: E Ratio: 150:1 To 1: 299N) Ramp Time: Up To 3 Seco) Inspiratory Time: 0.2 To 15Sp) Pause Time; Exp/Insp Holdq) Pressure Trigger: Up To -10Cmh2o And Flow Trigger Up To 20 Lpm;R) I Flow/T Plateaus) Resistance & Compliance (Cdyn & Cstat)T) Leakageu) P Plateau 14. Should Have Weaning Parameters;Rsbi,Vt Spont, R Spont ,Vt/Ibw15. Should Have Weaning Parameters;Rsbi,Vt Spont, R Spont ,Vt/Ibw16. Facility To Calculate Lower And Upper Inflection Point (P/V Flex Points)Should Have Recruitment Manoeuvre17. Should Have Automatic Suction Routine & O2 Flush18. Should Have A Dedicated Bronchoscopy Function To Allow & Compensate Ventilation While Performing Bronchoscopy19. Should Have Trend Of 7 Days And Above With Facility To Transfer Through Usb Interface20. Alarms Should Be User Friendly, Audio And Visual With Text Message, System Alarm Should Be For:A) Pressure Changes (High/Low)B) Tidal Volume Changesc) Minute Volume Changesd) High Peepe) High/Low O2 Concentrationf) Power Failure And Low Batteryg) Patient Disconnectionh) Apnea 21 A) The Ventilator Should Have Facility For Co2 Monitoring. Should Have Inbuild Etco2 Interface & Software To Accommodate External Optional Volumetric Etco2 In Future21 B) Should Be Upgradable To :Metabolic Monitoring (Indirect Calorimetry).Price To Be Quoted As Optional.22. The Ventilator Should Not Weigh More Than 12 Kgs 23. Ventilator Should Have In Built Non- Consumable Paramagnetic Oxygen Sensor That Shouldnot Require Change For At Least 5 Years.24. Flow Sensor Should Be Differential Pressure Technology, Or Ultrasonic.Flow Sensor Must Be At Expiratory End. Should Be Maintenance Free, Reusable And Autoclavable.The Flow Sensor, Inspiratory Port, Expiratory Port Should Be Easily Removable Without Using Any Tools & Should Be Autoclavable.25. Should Have Usb /Serial Interface For Communications With Networked Devices26. The Ventilator Should Have On Screen Help Menu For Alarm, Ventilation Mode & Ventilator Settings. The On Screen Help Menu Should Guide User On Solving The Alarms; Providing Information On Ventilation Modes & Settings. 27. Should Support Dual Limb Circuits Of Any Make And Not Ventilator Model Specific Circuits28. The System Should Have Inbuilt Rechargeable Battery With Backup With Minimum 2 Hours29. Power And Gas Requirements: A) Power Input To Be 220-240Vac, 50Hz (100-240 Vac) B) Gas Input (Air And Oxygen) - 29-100 Psi (29-87 Psi)30. The Ventilator Should Be European Ce Certified Or Us Fda Approved, And The Manufacturing Company Should Be Iso Certified.Accessories/Consumables To Be Supplied With Main Unit I. Icu Ventilator With Trolley – 1Nosii. Reusable Adultcircuit - 1 Nos Iii. Hinged Support Arm – 1 Nosiv. Hme Filters—5Nosv. Bacterial Filters-5Nos Vi. Hepa Filetr-1Nos Vii. Test Lung -1Nos Viii. High Pressure Oxygen Inlet Hose – 1Nos , Projector With Screen Brand - Epson / Benq / Lg Cinebeam Technical Specification Ce Marked, Power Supply: 220-240 V Ac, 50/60 Hz, Transparent Lcd Panel Display System, Minimum 5200 Hours Lamp Life, Min. 5800 Lumens Brightness, Contrast Ration 10000: 1, Aspect Ratio 16: 10, Resolution Xga (1024 X 786) With Hdmi And Vga In, Lan & Usb Support, Wireless Support, Light Weight, Remote Control Etc. , Phaco Emulsifier Machine Brand-Alcon Legion / Zeiss Technical Specification 1. Operating Frequency Should Be Approx. 40 Khz 2. Handpiece: Ultralight Ultrasound 4 Crystal Piezoelectric Hand Piece. 3. Us Modes: Continuous, Pulse, Single Burst, Multi Burst, Continuous Burst, Automated Programmable Modulation (Apm) 4. Automated Ultrasound Power On Demand: Ultrasound Management Technology That Automatically (De)Activates Ultrasound Us Delivered Only When Needed Ept Up To 50% Less & Better Followability. 5. Type Of Infusion: Iop Controlled, Synchronized Fluid Exchange System That Directly Measures And Simultaneously Controls Both Infusion And Aspiration Volumes In Real-Time. It Actively Compensates For Incision Leakage. Quattro Controlled Forced Infusion. 6. Display: 24 Inches Touch Screen. 7. Iop Range: 30-120 Mmhg 8. Vacuum Range 0 To 700 Mmhg 9. Aspiration Flow Rate 0 To 120 Cc/Min 10. Aspiration Control Modes: Vacuum Controlled Mode, Flow Control Mode 11. Chamber Stability: Irrespective Of Type Of Cataract, Surgical Conditions, Leakage (0 -12 Ml/Min) It Keep Chamber Stable & Maintain Targeted Iop Throughout Procedure. 12. Iop Recovery Time After Occlusion Break 200-250Ms For Vacuum In Range Of 200 -600Mmhg. 13. U/S Tips: Coaxial Phaco With Incision Size 2.2 Mm 14. Vitrectomy: Pneumatic Cutting Device15. Type Of Vitrectomy Cutter: 23G Anterior Vitrectomy Cutter16. Anterior Vitrectomy Range:Cut Rate 30 To 5000 Cuts Per Minute. 17. Actuation Medium For Vitrectomy: Compressed Air From Internal Source 18. Diathermy: Bipolar With Fixed And Linear Control Via Foot Pedal. 19. Type Of Diathermy Handpiece: Diathermy Forceps And Diathermy Pencil Eraser. 20. Instrument Tray Arm Length: Should Be 800Mm Or More. 21. Dual Linear Footswitch 22. Should Be Usfda And Ce Approved 23. Online Ups Should Be Providedaccessories: Phaco Hand Piece(Coaxial) -2 Coaxial Handpiece Tip I – 2 I/A Bi Manual Hand Piece – 2Phaco Tip (2.2 Mm)- 10 Phaco Sleeve (Silicone)(2.2Mm) – 10 Test Charnber- 10 Tubing And Cassettes (Disposable) – 100 Diathermy Cable With Forceps – 2 Phaco Wrench-2 Vit Cutter- 23 G; Single Use – 6Sterilization Container/ Tray , Autorefractometer & Keratometer (Ark) Brand-Zeiss- Visuref 150 Technical Specification (A)Device Data.(A) Refraction(1) Sphere -25.00D To +22.00D (In Steps Of 0.12D/0.25D)(Ii) Axix 0 To 180*) (B) Keratometer(A) Corneal Curvature 5.00 To 10.20Mm (In Steps Of 0.01Mm)(B)Corneal Redraction-33.000 ?? 67.50D (In Steps Of 0.12D/0.25D)(C) Corneal Astigment-0.00D To-15.00D50d (In Steps Of 0.12D/0.25D)(D)Axis 0 To 180* (In Seps Of 1*) (E) Corneal Diameter (2.00 To 1200Mm (In Steps Of 0.10Mm) , Humphrey Fied Analyzer ( Hfa3) Brand-Zeiss Technical Specification • High Quality Goldman Standard Automated Full Field Perimetry Of International Standard With Bowl Size Radius = 30Cm. • Computer & Monitor Should Be Integrated In The Perimeter (No External Computer). • Stimulus Size I, Ii, Iii, Iv & V.• Background Illumination 31.5Asb.• Maximum Temporal Range 80Deg.Suitable For Central 30, Neurological Tests As Well As Full Field Testing. • Central Field Test Patterns 30-2, 24-2,10-2, Macula.• Peripheral Field Test Pattern 60-4, Nasal Step, Custom Test. • Threshold Test Strategies Full Threshold, Sita Standard, Sita Fast , Full Threshold, Fast Pack, Sita - Swap.• Screening Field Test P-60, Ff-80, Ff-120, Ff-240,Nasal Step For Periphery .• Screening Test Strategies Two Zone, Three Zone And Quantify Defects.• Glaucoma Hemi Field Test, Heijl –Krakau Blind Spot Monitor• Video Eye Monitoring, Gaze Tracking Monitoring System, .. Vertex Monitoring And Head Tracking. • Touch Screen On Crt Monitor, Keyboard & Provision Of External Monitor & Keyboard.•Internal Hard Disk Drive.• Stimulation Duration 200Ms, Wavelength Broad Band Visible Light• Stimulus/Background Colour White On White.• Swap (Blue On Yellow) Perimetery. • Auto Pupil Measurement. • Kinetic Testing & Custom Kinatic Testing. • Motorised Chinrest, Motorised Table, Laser Jet Printer • Glaucoma Progression Analysis ( Gpa ) Software For Monitoring Disease Progression. With Visit Wise Graph &Visual Field Index (Vfi).• Releye Monitor.• Forum Software For Archiving & Offline Analysis Of Patient Data & Gpa Analysis Etc.• Hfa Dicom Gateway. , Laser Dcr Brand-Medfin Technical Specification Applicationsdacryocystorhinostomy Amplifying Medium Diode Ergonomics Tabletop Wavelength-980Nm Average Power -8W Weight -1.2Kg (2.65Lb) , Automatic Tourniquet System With Hose Cuffs Brand - Zimmer Biomet (Model Ats-5000) Number Of Ports Dual Port Number Of Potential Cuffs Dual Cuff Dual Cuff Mounting Options Table Or Pole Mount Table Or Pole Mount Battery Type And Life Lithium Ion 6 Hrs Lithium Ion 6 Hrs User Interface Touchscreen Touchscreen International Alarm Standard 60601-1-8 Compliant Compliant Display 10.1” Color 7.0 Color Minimum/Maximum Pressure 20/600 Mmhg 50/600 Mmhg Pressure Accuracy ±3 Mmhg (20–600 Mmhg) ±4 Mmhg (50-600 Mmhg) Limb Occlusion Pressure (Lop) Allows For Patient Specific Pressure, Which Allows For The Minimum Pressureto Be Used.Yes Noline Occlusion Detection (Acoustic Reflectometry)A Kinked Pneumatic Tube Can Prevent An Inflated Cuff From Deflating, Resulting In Unintentional Tourniquet Pressure. This Alarm Alerts Or Staff That There Is An Occlusion In The Line To The Cuff.Yes , Battery Opreated Heavy Duty Drill & Saw Brand -Manman/Biotech Specifications--- Drill And Reamer Hand Piece Attachments, Oscillating/S Reciprocating Saw Hand Piece Charger And Sterilization Handpiece For Drilling & Reamingtrigger Type Single Modes Available - Reverse & Forward Modedrill Speed 1000 Rpm Approxdrill Torque 4 Nm (35+ In Lbs)Ream Torque 16.5 Nm (145+ In. Lbs)Weight Of Hp With Batteries 1250 Gms Drilling And Reaming Attachments Hudson/Zimmer/Trinkle Reamer Attachment - Yesao Reamer Attachment - Yesao Type Drill Attachment With Quick Coupling - Yesjacobs Chuck With Minimum 6 Mm - Yeskeyless Chuck -Yes Wire Driver Attachment - Yespin Driver Attachment - Yes Dhs Reamer Attachment With Quick Coupling - Yesoscillating/Sagital Saw Hand Pieceergonomic Pistol Grip Design For Maximum Comfort And Control Yes Weight Of Hp With Batteries.- 1350 Gmssaw Speed - 15000+ Cpmcutting Arc - Between 4 To 5 Degreenoise Level - 60-85 Dblspecial Blades Each For Tkr And Thr (Nos) - 10 Battery Specifications Type Of Battery Lithium Ion (Li-Ion) Number Of Batteries 2 , Electric Cautery Machine Brand - Shalya/Enertech/Eclipse/Valley Lab 1) Unit Should Have Microprocessor-Controlled Tissue Feedback Technology 2) Unit Should Have No Of Bipolar Modes Available 3) Unit Should Have Pure Sinusoidal Output Waveform In Hf Power Output In Cut And Bipolar Modes. 4) Type Of Display Should Be Lcd Touch Screen 5) It Should Adjust Power Level Automatically Depending On Tissue Type. 6) It Should Have Two Monopolar Output Channels. 7) Bipolar Current Meter Bipolar Current Meter 8) Unit Should Deliver Two Coagulation Output At A Time With Independent Control Over Each Output For On & Off. 9) Both Channels Should Work By Foot And Hand Control. 10) It Should Complete Self Testing During Power On. 11) Power Efficiency 98 Or More Than 98 12) Availability Of Advance Cutting Modes For Regular Open Surgery 13) It Should Accept Disposable And As Well As Reusable Patient Plate. 14) Unit Should Have Tissue Feedback, Pulsed Interval-Controlled Pulse Cut Function. 15) It Should Accept Dual Area And Single Area Patient Return Electrode. Should Give Green Indication If Dual Area Patient Plate Applied To Patient & Red Indication With Alarm Tone If The Patient Plate Is Not Applied. 16) Bipolar Should Work Without Patient Plate Or Patient Plate Error Condition. 17)Bipolar Should Have Auto Facility To Start & Stop Working Without Footswitch. 18) Unit Should Have Adjustable Delay Activation In Auto-Bipolar. 19)It Should Have Randomized Spray Coagulation For Larger Area Coverage.20)It Should Be Upgradeable For Argon Delivery Module From The Same Oem.21) Unit Should Be Useful For Underwater Procedures. 22) It Should Have Alarm Facility After Completion Of Bipolar Coagulation. 23) Unit Should Have Time Out Function For Automatic Stop The Hf Output If Prolong Unintended Activation. (Optional)24) Unit Should Have Touch Key Pad For Power And Mode Selection.25) System Should Give Error For Faulty Handswitch Of Footswitch In Monopolar & Bipolar.26) Unit Should Give Error For Faulty Keypad. 27) It Should Have No Of Segments Of Display 3. 28) Unit Should Operate From 180 V To 265 V Without Using External Stabilizer. 29) It Should Have Independent Foot Switch For Monopolar Two Paddle. 30) It Should Have Independent Foot Switch For Bipolar Single Paddle. 31) Unit Should Have Facility To Connect Either Monopolar & Bipolar Footswitch.32) Unit Should Have Remote Power Setting Facility From Sterile Field With Conventional Hand Switching Pencil. 33) It Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification. 34)Manufacturer Iso 9001: 2008 & En Iso 13485:2012 Certified Company.35) Warranty Must Be 3 Years Or Higher 36) It Should Be Supplied With Following Reusable And Autoclavable Accessories: -1. Patient Return Electrode …………………….1 No.2. Hand Switching Pencil………………………. 1 No.3. Foot Switching Pencil…………………………1 No.4. Bipolar Forceps …………………………………1 No.5. Cable For Bipolar Forceps……………………1 No.6. Monopolar Footswitch ………………………1 No.7. Bipolar Footswitch ……………………………1 No. 8. Universal Adaptor …………………………….1 No.Set Of Electrode (Angled, Ball And Needle).1No10. Trolley With Lockable Castor Wheel Should Be Supplied1. Unit Should Be Eu Ce (4 Digit Notified Body Certified)2. All Sockets Should Be Of Blinking Light Type When In Use To Identify The Used Mode 3. Availability Of Test Report From Central Govt/ Nabl/Ilac Accredited Lab Covering All Parameters. And Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification. , Arthroscopy Set (Brand- Smith +Nephew / Karl Storz) Arthroscopy Set 30° (Arthroscopic, Sheath And Obturator) Wide Angle, Direct View 4K High Definition Arthroscope. Light Guide Insertion On Definitione Direction View With A J-Lock Fixation For Cannula.Working Length Of Not More Than 160Mm Optimal Centre-To-Edge Resolution For Enhanced Picture Quality Angle Of View: 30 Degree Diameter: 4Mm Arthroscopies Should Be Supplied With Compatible Cannulas High Flow, Double Valve, Fully Rotatable With Fenestrated Tip & Conical And Blunt Tip Obturator, Sheath- 5.95 To 6.0Mm, High Flow Diagnostic Cannula, Double Valve, Fully Rotatable Cannula With Fenestrated Tip. Trocar-4.5Mm Conical Obturator To Fit With Cannula. Arthroscopy Set 70° (Arthroscopic, Sheath And Obturator) Wide Angle, Direct View 4K High Definition Arthroscopic Light Guide Insertion On Opposite Side Of The Direction Of View With A J-Lock Fixation For Cannula. Fully Rotatable With Fenestrated Tip & Conical And Blunt Tip Obturator. Sheath- 5.95 To 6.0Mm, High Flow Diagnostic Cannula, Double Valve, Fully Rotatable Cannula With Fenestrated Tip. Trocar-4.5Mm Conical Obturator To Fit With Cannula. Arthroscopic Power Shaver System: Input Voltage Of 100 To 240V, 50/60 Hz Power Consumption Not More Than 350Va. Two Separate Receptacles For Motor Drive And Powered Instrumentation. Shaver Should Have 2 Modes Of Oscillation For Aggressive Cutting Shaver Should Have Button For Flush Lavage Of Joints On Footswitch. Autoclavable Ultra-Light Hand Piece With Suction Facility, With 3 Hand Control Buttons And Replaceable Cable Long 10Ft (3 M). Maximum Torque Should Not Be Less Than 32Oz.In And Weight Should Not Be More Than 212 Gms Pedal Style Footswitch With 3 Operating Modes I.E. Forward, Reverse And Oscillation. On-Line Lcd Display For Speed And Direction Referral. Should Communicate With The Fluid Management System Once Connected With The Cable. Camera Control Unit: System Must Have Inbuilt 4K Uhd Camera Console, Led Light Source & Wifi Enabled Image Management System With Recording Via Usb Port Along With Recording In App Through In Built Wifi. Camera Resolution Must Be 3840*2160 (Native) 4K Camera Head: Camera Head Should Have 4K, 3 Chip Mos Video Sensor Technologymust Have Transport Shock And Vibration Compliance With Ista 3Avideo Field Rate 60 Hz Must Have C-Mount Autoclavable Coupler With 19.5 Mm Coupler Length Opt For 4Mm Scopes Must Have Digital Zoom Video Data Transmission High-Speed, Low-Voltage Differential Serial (Lvds), Digital Transmission Via 12-Foot Camera Cablevideo Output Format Full Uhd 2160P, 100% Compatible With Smpte St-425-5 When Used With The Ccu Altitude: 3000 Meters Maximum 4K Monitor: Monitor Should Have Resolution 4096 * 2160 Pixels Monitor Should Support Picture Size (Diagonal) 789.06 Mm (31 1/8 Inches) 1387.8 Mm (54 3/4 Inches) Monitor Should Support Effective Picture Size 698 * 368.1 Mm (27 1/2 * 14 1/2 Inches)Monitor Should Support Pixel Pitch 0.1704 X 0.1704 Mm Monitor Should Have Aspect Ratio Of 17:09Monitor Should Have Pixel Efficiency Of 0.9999 Size Is -125Mb 1300 Seconds Video / Gigabyte Storage 10000 Images/Gigabyte Storage Airprintt Is Required. , Fess Instruments Set Nus Surgery Fess & Dcr Surgery Instruments Brand -Kalelkar / Besco Blakesley Forceps 0 Blakesley Forceps 45Blakesley Forceps 90° Thrucut Forceps 0Thrucut Forceps 45° Thrucut Forceps 90 Maxillary Sinus Forceps 30, 90, 120Hewiser Forceps Tubular Rotatable Kerrison Punch Straight Kerrison Punch Curved Backbiting Forcep Tubular Rotatable Stammberger Ostrum Punch (Mushroom Forceps)Giraffe Forceps Upturned 55, 70, 90, 110 With Vertical Or Horizontal Opening Fronntal Sinus Bougie Set Of 4Sickle Knife Sharp/Blunt Ball Probe Double Ended Right Angledball Probe With J Hook Double Endedantrum Curette Oval Or Round Cup Suction Canulla 45 Or 90° , Micro Ear Surgery Instrument Set (Ear Surgery Instruments) (Stapedectomy Instruments) Brand -Kalelkar / Besco Technical Specification Sickle Knife , Circular Knife Flag Knife , Sickle And Flag Knife Double Ended , Sickle And Circular Knife Double Ended Circular And Flag Knife Double Ended , House Curette Double Ended, Elevator Pick Straight/Curved/Right Angled , Fisch Perforator 0.3 Mm To 0.8 Mm. Hand Burr , Piston Depth Guage , Stapedectomy Instruments , Piston Cutting Jig Piston Autoclaving Box , Teflon Pistonspistion Crimper Micro Ear Scissor Belluchi Operative Ear Speculam Set Of 4 Black Slotted Or Plain Endural Retractor 2X2endural Retractor Left/Right Plester Micro Suction Canulla 116 To 24Gmicro Suction Canulla Adaptor Silicone Suction Tubecartilage Slicer , Tonsillectomy Instruments Set Brand -Kalelkar / Besco Technical Specification Davis Boyles Mouthgag With 5 Blades Davis Boyles Mouthgag With 5 Slotteddraffin Bipod Stand With Plate Tonsil Holding Forceps Tonsil Dissector Cum Pillar Retractortonsil Dissection Forceps Tonsil Artery Forceps Straighttonsil Artery Forceps Curvedtonsil Artery Forecps Negustonsil Scissor Tonsil Snare Tonsil Snare Wire +Quincy Foreps +Adenoid Curette With Cage + Adenoid Currette Without Cage + Younker Suction Canulla +B.P.Handle No 7 + Negus Knot Tier +Thrroat Instruments Tracheatomy Surgery Instruments + Tracheatomy Tube Chevalier Jackson/Fuller + Mosquito Artery Forceps + B.P.Handle No 3 + B.P. Blade No 11 + Fine Scissor 4 +Tracheal Dilating Forceps + Kilner Catpaw Retractor +Skin Hook + Single Hook Retractor +Double Hook Retractor , Nasal Surgery Instruments Set (Septoplasty Instruments) Brand -Kalelkar / Besco Technical Specificationkillians Nasal Speculam 2 To 3.5 + St. Clair Thomson Nasal Specularm Set Of 4 B.P. Handle No 3+Freersdouble Ended Mucopericondrial Elevator + Symes Double Ended Mucopericondrial Elevator + Howarth Double Ended Mucopericondrial Elevator Symes Double +Suction Elevator + Lucs Forceps Round Or Heart Shape + Jensen Middleton Septum Cutting Forceps + Jensen Middleton Septum Punch Forceps + Turbinectomy Scissor + Ballenger Swivel Knife Bayonet Shape + Tilleys Nasal Gouge Bayonet Shape With V Cut Or. Plain + Hammer (Mallet) + Submucosal Diathermy+ Needle/Ball Probe + Nasal Packing Forceps + Spring Scissor + Catspaw Retractor + Tongue Depressor + Rhinoplasty Surgery Instruments + Raps + Cricoid Hook + Jenkins Chisel + Alar Retractor + Aufritch Nasal Retractor + Ash Septum Forceps + Walsham Septum Forceps + Gillies Osteotome + Nasal Packing Forceps + Silver Nasal Chisel With Guard Left/Right + Skin Hook + Cottle Retractor + S.M.R Instruments + Killians Nasal Speculam 2 To 3.5 + St. Clair Thomson Nasal Speculam Set Of 4 + Freers Double Ended Mucopericondrial Elevator + Symes Double Ended Mucopericondrial Elevator + Howarth Double Ended Mucopericondrial Elevator + Suction Elevator + Turbinectomy Scissor + Ballenger Swivel Knife Bayonet Shape + Tilleys Nasal Gouge Bayonet Shape With V Cut Or Plain + Hammer (Mallet) , Micro Laryngeal Surgery Instruments Set Brand -Kalelkar / Besco Laryngoscope Mls Black Finish Adult/Child/Paediatric With Fiber Optic Carrier Chest Supportlaryngoscope Distending Operating Type Laryngoscope For Filling With Endoscopemls Forceps Cup Type Straight/Left/Right/Upward/Downward Mls Forceps Serrated Type Straight/Left/Right/Upward/Downwardmls Scissor Straight/Left/Right/Upward/Downward Mls Vocal Cord Spreader Mls Mini Larygeal Forceps Triangular End Mld Needle Holdermls Ssickle Knife Mls Circular Knifemls Flag Knifemls Probe 45°, 90°Mls Curettemls Handle For Use With Straight Instumentssuction Tube With Thumb Control Insulated Probe For Coagulationbronchoscope/Esophagoscope & Instrumentsbronchoscope Negue Type Any Size With Fiber Optic Carrier Esophagoscope Any Size With Fiber Carrierhypopharyngoscope (Esophageal Speculam) With Fiber Optic Carrier Forceps Alligator Grasping Single Actionforceps Peanut Soft Tissue Single Actionforceps Cub Biopsy Type Single Action Forceps Patterson Type Single Actionforceps Universal Biopsy & Grasping Single Actionforceps Alligator Grasping Double Actionforceps Peanut Soft Tissue Double Actionforceps Cup Biopsy Type Double Actionforceps Patterson Type Double Actionforceps Universal Biopsy &Ngrasping Double Action Suction Tube Rigid With Thumb Conntrol , Mastoid Surgery Instruments Set Brand -Kalelkar / Besco B.P. Handle No 4 Kilner Catspaw Retractormollison Mastoid Retractor 3X3 Mollison Mastoid Retractor 4X4mahadevaiah Modified Mastoid Retractor Left/Right Jensen Retractorjolls Retractor Periosteal Elevatoroperative Ear Speculam Set Of 4 Black Slotted Or Plain Micro Suction Canulla 11G To 24Gmicro Suction Canulla Adaptor Mastoid Suctioncanulla Set Of 4 With Thumb Grip Sickle Knifecircular Knifeflag Knife House Curette Double Ended Elevator Adsons Toothed Forceps Adsons Non Toothed Forceps Needle Holder 6 Fine Scissor 4Micro Ear Crocodile Serrated Forceps Micro Ear Crocodile Cup Forceps Micro Ear Crocodile Scissors Malleus Nipper Ball Probe 45 Degree/90 Deegre Vien Graft Pressossicle Holding Forceps , Fiberoptic Flexible Video Laryngoscopy System Brand -(Penlon / Karl Storz) Specification 1) It Should Be Very Portable And Light Weight Device With Minimum Display Size Should Be 4 Inch With High Resolution Anti Reflective Display. 2) Should Have 180 Degree Horizontal Screen Rotation With Vertical Movement For Betterclinical Assistance. 3) It Should Be A Lithium Ion Rechargeable Battery-Operated Device With Low Battery Indicator. 4) Minimum Operation Item Should Be 130 Mins. 5) It Should Have Led Light Source At The Tip Of The Blade With Minimum 2 Megapixel Cmos Camera For Better View. 6) It Should Have Channelled And Without Channelled Blade Option. 7) Should Have 4Gb Inbuilt Memory For Continuous Recording & Image Capturing. 8) Blades Sizes Should Be Size 1,2, 3, 4,5 . 9) Blade Should Be Affordable, Sterile Which Connect Laryngoscope Handle With Lock. 10) Battery Life Cycle Should Be Minimum 300 Times. 11) It Should Have Iso & Conformity To Ce. , Fiber-Optic Video Bronchoscope(Brand - Karl Storz /Olympus ) Specification Fiber-Optic Video Bronchoscope Required With Video Illumination To Visualize And Document The Operational Area On Screen. It Should Consist Of Following Features: Monitorscreen 8 To 12 Inch In Size For Display With Touch Screen To Control Features With Hdmi Output For Connecting To A Big Screen Which Can Display Picture Simultaneously On Both Screens.Monitor Should Have Two Ports To Connect Two Video Endoscopes At One Time And Pictures Can Be Swapped Using Touch Screen. Monitor Should Be Chargeable, To Be Supplied With Charger And Should Have Facility To Be Used While Charging. Monitor Resolution Should Be Minimum 1920 X 1200 Pixels In 16:9 Format.Integrated Recording Of Video & Still Images Should Be Possible On Data Card Or Usb Drive With Jpeg And Mpeg Format Which Can Be Easily Transferred To The Computer/Laptop. Documented Videos & Still Images Should Be Easily Recalled On The Monitor. Monitor Should Have A Facility To Connect Flexible Scope Directly Without Any Special Coupler Or Accessory. Monitor Should Have Picture-In-Picture & Side-By-Side Mode To View Images From Flexible Video Scopes. Monitor Should Be Splash Proof According To Ip 54 And Should Be Shock Resistant.Monitor Should Have Lithium-Ion Rechargeable Batteries And Run For At Least 100 Mins. When Fully Charged. Soft Bag From Same Manufacturer Should Be Supplied To Place The Monitor And System Can Also Be Operated Without Taking Monitor Out From The Bag. Same Monitor Should Be Compatible With All The Below Mentioned Scopes Of Same Manufacturing Principal Company .Reusable Fiber Optic Video Bronchoscope.Single Use Flexible Intubation Video Endoscope A Fiber Optic Bronchoscope Is A Medical Device Used To Visualize The Airways During Bronchoscopy, A Procedure Where A Thin, Lighted Tube Is Inserted Into The Lungs To Examine Them. The Specifications Of A Fiber Optic Bronchoscope Typically Include Its Outer Diameter, Working Length, Field Of View, Angulation Capabilities, And The Diameter Of Its Working Channel. Key Specifications:Diameter: Bronchoscopes Come In Various Sizes, With Outer Diameters Ranging From 2.5 To 10 Mm. Smaller Diameters (E.G., 4.9 Mm) Are Suitable For Smaller Patients, While Larger Diameters May Offer Better Image Quality And Suction Capabilities. King Length: The Working Length, Which Is The Distance From The Distal End Of The Bronchoscope To The Insertion Point, Typically Ranges From 30 Cm To 60 Cm. View: This Refers To The Angle Of Vision That The Bronchoscope Offers. A Wider Field Of View (E.G., 110-120 Degrees) Allows For A Broader View Of The Airways. Angulation: The Ability To Bend The Tip Of The Bronchoscope Allows For Maneuvering Into Various Airways. Up And Down Angulation Capabilities Are Typically Around 180 Degrees And 130 Degrees Respectively King Channel Diameter: The Working Channel Is The Passage Through Which Instruments Like Forceps For Biopsies Or Suction Devices Can Be Passed. It Is Typically 1.2-2.3 Mm In Diameter Other Notable Specifications: 26/25 All Above Equipment Should Be From Same Manufacturers And Usfda & Ce Approved , Anaesthesia Workstation Complete With Anaesthesia Gas Delivery System, Vaporiser, Circle Absorber System With Built In Anaesthesia Ventilator & Withmultipara Monitor Brand - -Drager/Penlon/Bpl General • Should Have Provision For Delivery Of Oxygen, Nitrous Oxide And Medical Air • The Machine Should Be Capable Of Delivering Low Flow Anaesthesia. • The Anaesthesia Machine With Circle Absorber, Ventilator And Vaporiser Should Be From Same Manufactureranaesthesia Machine Should Be Ce Notified Body Approved. • Anaesthesia Machine Should Be Cdsco Approved. Vaporizer Should Be Us Fda Approved.Should Have Independent Attachments For Connecting Central Gas Supply And Pin Indexed Cylindershould Have Non-Interchangeable Pipeline Hose Inlet Connection To Pipelines For Medical Oxygen, Nitrous Oxide, And Medical Air Should Have Large Size Pressure Gauges, For Easy Visibility, Colour Coded, Two Each For Oxygen And Nitrous Oxide; One For Airanaesthesia Machine Frame Shall Be Manufactured In Strong But Lightweight Material.The Machine Shall Have A Maximum Of Four Castors/Wheels For Manoeuvrability With Front Two Castors Having Brakesshould Have Minimum Two Non-Lockable And Spacious Drawers For Storing Accessoriesthe Frame Shall Have Gcx Compatible Channels Incorporated For Mounting Other Accessories. • The Option For An Integrated Independent Oxygen Flow Meter For Oxygen Delivery Is Mandatory. Frame Shall Accommodate Up To Two Backup Cylinders One Each For Oxygen And Nitrous Oxideon Activation Of The System On/Off Switch Gas Flow And Vaporization Shall Immediately Be Availableshould Have Selector Switch For Selecting Open And Close Circuit Operation • The Common Gas Outlet Shall Be Mounted At The Front Of The Machine (Not Rear Or Side) To Be Easily Accessible In The Event Of An Emergency And For Use Of Alternate Breathing Circuits • The Option For Illumination Of The Writing Table/Work Surface Is Mandatory • The Frame Should Have Integrated Power Outlets To Supply A Minimum Of Three External Devices • Should Have Top Shelf, Manoeuvring Handle And Footrest • Machine Should Have Table Topwork Space To Keep Drugs. • The Unit Should Have A Battery Back-Up Facility For The Ventilator In The Event Of Power Loss. Minimum 90 Minutes Battery Backup Required. • Input Power :100 – 240 Vac Gas Flow • Antistatic And Cascaded Dual Flow Tubes Should Be Available For All Gases (O2, N2o& Air) To Allow Suitable Resolution And Accurate Control At Low Total Fresh Gas Flows. • The Flow Range Shall Be 150Ml-10 Lpm • Should Have N2o Cut Off Facility If O2 Supply Fails. • Should Have Oxygen Failure Alarm Both Visual And Audible. • Should Have Oxygen Flush Facility Bypassing Vaporiser. O2 Flush Switch Should Be Conveniently Placed For Easy Accessibility. O2 Flush Switch Should Be Non-Lockable. • The Unit Shall Have A Mechanical Anti-Hypoxic Device (Ahd) System To Control The Ratio Of Oxygen And Nitrous Oxide. A Completely Mechanical Ahd System, That Requires No Electricity, Is Mandatory • The Mechanical Ahd System Must Limit Minimum Oxygen Levels To Approximately 25% • Should Have Minimum Mandatory Oxygen Flow Of 100 Ml When Switched On • It Shall Be Possible To Deliver Air With Only Basal Flow Oxygen Independent Of The Abovementioned Hypoxic Control. • Gas Flow Shall Be Controlled Mechanically Only • Visual Display Of Individual Gas Flows Is Mandatory, This Shall Be By Physical Means Such As Glass Flowmeters Independent Ofelectrical Power • Flow Meters Should Have The Option Of Backlight Illumination • In The Event Of Complete Power Loss And Battery Failure It Shall Still Be Possible To Set The Fresh Gas Flow Accurately For Each Gas, Manually Ventilate (With Bag) And Continue To Keep The Patient Anaesthetized. • Anaesthesia Machine, Vaporizer And Ventilator Should Be From Same Oem. • Provide Isoflurane And Sevoflurane Vaporizer With Themachine. Vaporizers • The Unit Should Accommodate At Least Two Vaporizers For Anaesthetic Agent Delivery. • The Manifold Should Only Accept Vaporizers With Approved Back Bar Connections And Prevent Usage Of More Than One Vaporizer Simultaneously. Preferably Selectatec Compatible Back Bar. • Vaporizers Supplied With The Unit Shall Be Routine Maintenance Free For The Life Of The Product • Vaporizers Supplied With The Unit Shall Be Manufactured From Lightweight Materials To Aid In Fitting & Removal • Should Have An Operating Flow Range Of0.2 – 15 L/Min And Nominal Capacity 250 Ml Ventilator • Ventilator Shall Cater For A Diverse Range Of Patient Groups From Neonates To Adult Patients With Restrictive Airways • Ventilator Should Be Pneumatically Driven And Controlled Electronically • Ventilator Shall Have A Large 8.4” Colourtft Display, For Exclusive Use Of Ventilator Control And Monitoring. • Control Ofthe Ventilator User Interface Shall Be By Touch Screen And Rotary Dialventilator Shall Have The Following Ventilation Abilities, Volume Control (Vcv), Pressure Control Ventilation (Pcv), Simv-V And Simv-P ,Spont/Pressure Support Ventilation (Psv),Manuaassisted Modes Of Breathing Shall Be Flow Triggered. Ventilator Shall Compensate For Fresh Gas Flow And Compliance Of The Entire Circuit. Should Have User Adjustable Alarms For Major Parameters Such As Tidal Volume, Minute Volume,Fio2,Airway Pressure, Frequency Apnea Alarms Must Be User Adjustableto Allow For All Operating Conditions And Phases During Anaesthesia Ventilator Should Have The Ability To Display Patient Spirometry Loop Ventilator Should Also Display Waveforms For Flow, Volume And Airway Pressure Stem Absorber & Not Remoted Via Tubes Or Channelsvolume Measurement Sensors Should Not Be Disposable Typeventilator Parameterstidal Volume- 10Ml-1600 Mlfrequency- 4-100 Bpm I:E Ratio- 4:1 To 1:10 Inspiratory Pause - 0-60% Of Ti Peep - Off, 3-30 Cmh2o Pressure Limit - 5-70 Cmh2o Minute Volume-0.5 To 60 Lpm Breathing System • The Breathing System Designed So That It Can Be Removed & Replaced As A Complete Unit Without The Use Of Tools • All Parts Of The Breathing System That Are In Contact With Patient Gas Shall Be Latex Free And Autoclavable Except For Non Autoclavableremovable Part Like O2 Sensor And Pressure Manometer. • Bag/Vent Switch Shall Be Integrated On The Absorber And Should Activate Ventilator In Vent Mode And Vice Versa (One Step Operation). • Breathing System Should Have Heater System To Avoid Water Condensation. • Should Have Quick Release Canister For Sodalime , Capacity Minimum 1.5 Litre • The Breathing System Absorber Canisters Shall Have A Bypass System To Allow For Canister Change Mid-Case Without Loss Of Ventilation Pressure. The Requirement For An Automatic Bypass Without Extra Input From The User Is Mandatory • The Ventilator Bellows Shall Be Clearly Visible And Be Of Upright Design.The Bellows Should Ascend On Expiration To Provide A Quick Visual Indicator For Assisted Breathing, Spontaneous Breathing And System Leaks. • Same Bellows Shall Be Used For Adult And Pediatric Application • Should Have Provision For Fio2 Monitoring Cell And Fio2 Value Should Be Monitored On The Main Screen. • A Bag Arm With Positional Adjustment Shalmulti Parameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,( Massimo),Nibp (Suntech) Temperature,Dual Ibp, Agm ( Massimo) Mainstream. 3. Should Have 12-Inch Color Lcd Display. 4. Should Have Dual Modes Of Operation: Rotary Knob. 5. Should Display 7 Waveforms Or More 6. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen. 7. Ecg: ? Should Be Able To Monitor Ecg Through 5-Lead Patient Cable ? Should Have Manual St Analysis Window ? Should Detect 20 Arrhythmias And Generate Alarms. ? The Priority Of Arrhythmia Alarms Can Be Configurable ? Should Measure Pvc & Pac ? Should Be Able To Monitor Heart Rate From 10-300 Bpm ? Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etc ? Should Have Pacemaker Detection Facility 8. Respiration: ? Measurement Range Of 0 To 150 Breaths Per Min ? Should Have Gain Selection: ×0.25, ×1, ×2, ×4 ? Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S ? Should Have Apnea Detection Facility ? Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 9. Spo2: ? Should Have Massimo Technology ? Should Have Measurement Range Of 0~100 % ? Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph ? Should Be Able To Select Sat Sec To Avoid False Alarm 10. Nibp: ? Must Be Of Suntech Medical Technology For Clinical-Grade Blood Pressure Measurement ? Should Have Auto, Manual, And Stat Modes Of Operation For Nibp. ? Should Have A Measuring Range Of 0-280 Mmhg 11. Should Have 2 Channels For Temperature Monitoring 12. Should Have Data Storage Capabilities: O 72 Hours Of Trend Data Storage. O 2000 Sets Of Nibp Measurement Data. O 200 Alarm Events O Physiological Alarms Can Be Reviewed With 16 Sec Of Associated Waveform Along With Other Parameter Values. Even Print Out These Waveforms With Optional Recorder O 7 Leads Of Ecg Waveform Disclosure At Least Of 1-Hour O Should Have Facility To Transfer The Trend Data To Usb 13. The Monitor Should Have Drug Dose Calculator And Oxy-Crg View Screens 14. Snapshot Facility With Usb Transfer. 16.Should Have Alarm Settings For All Parameters. 17.Should Have Color Coded Alarms And Alarms Priority Can Be Configurable. 18. Should Have Cns Connectivity Of Same Make. 19.Monitor Should Be Able To Directly Connect With Hospital Information System (His 20.Should Have Standby And Night Mode 21.Should Have Li-Ion Battery 22.Battery Should Have 3.5 Hrs Of Operation 23.Monitor Should Be Ce Certified 24.Manufacturer Should Be Iso Certified 13485:2016 , Bi-Phasic Defibrillator Brand - Bpl/Maestros Technical Specifications For Bi-Phasic Defibrillator • The Machine Should Have Facility For Ecg Monitoring, Bi-Phasic Defibrillation,With Facility To Print Ecg Through In-Built Thermal Printer,• Should Be Extremely Light-Weight (Less Than 10 Kgs) • Should Have Monitoring Facility Through Color Tft Display With Screen Size At Least 7” Or Better. • Should Have Both Synchronous And Asynchronous Mode. • The Defibrillator Should Be Biphasic Technology Based Having Energy Selection Of 2-300 Joules• It Must Be Capable Of Monitoring Ecg Through Ecg Cables, Multi-Function Electrodes And External Paddles. • The Machine Should Be Able To Defibrillate Adult, Paediatric Patients. • The Machine Should Have Ecg Wave Form Display On Bright Screen Along With Other Vital Numeric Information. • Should Be Able To Monitor Ecg• Should Have Facility For Auto Testing When Switched On And During Operations. • The Machine Should Be Compact, Portable With Built In Rechargeable Battery. • Should Have External Pacemaker With Fixed Or Demand Mode. • Should Be Able To Deliver A Maximum Of 300J In Aed Mode • Should Have A Minimum 2 Hours Battery Capacity For Monitoring And 1 Hour Battery Capacity For Giving Minimum Of 100 Shocks.• Energy Selectiononfront Panel Button And External Paddle Buttons • Charge Control On Front Panel Button And External Paddle Buttons • Charge Indicator Charging Tone, End Of Charge Tone, Led In Charge• Shock Control Buttons On The External Paddles • Should Have External Defibrillator Adult And Paediatric Paddles.• Charging Time - Less Than 8 Seconds At 300 J With A New And Fully Charged Battery • The Machine Should Have User Selectable Alarm Settings• The Machine Should Store At Least 24 Events For Viewing Or Recording.Ecg: • Should Be Able To Monitor Ecg Through 5-Lead Patient Cable • Should Be Able To Display Lead I,Ii,Iii, Avr, Avl, Avf And One Of The Chest Leads• Should Be Able To Monitor Heart Rate From 15-300 Bpmgeneral Specifications• The Machine Should Work On Mains As Well As Rechargeable Battery. • The Device Should Be Manufactured From An Iso Certified Organization• Machine Should Be Supplied With Standard Accessories• System Should Be Easy To Operate With Facility To Give Print Command, Charge And Energy Selection On Both External Paddles And On The Main Unit.• Should Have Upgradable Facility For Masimo Etco2.• Should Have Upgradable Facility For Spo2.• Should Have Upgradable Facility For Nibp.• Should Have Upgradable Facility For Pacer Also. , Multi Para Monitor With P, Nibp, Ecg Facility (Brand - Bpl/Maestros/Drager)) Technical Specifications For Multipara Monitor 1. Multi Parameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,( Oxyset+), Nibp (Suntech) Temperature. 3. Optional Parameter Etco2, Dual Ibp, Agm 4. Should Have 12-Inch Color Lcd Display. 5. Should Have Dual Modes Of Operation: Rotary Knob. 6. Should Display 7 Waveforms Or More 7. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen. 8. Ecg: ? Should Be Able To Monitor Ecg Through 5-Lead Patient Cable ? Should Have Manual St Analysis Window ? Should Detect 20 Arrhythmias And Generate Alarms. ? The Priority Of Arrhythmia Alarms Can Be Configurable ? Should Measure Pvc & Pac ? Should Be Able To Monitor Heart Rate From 10-300 Bpm ? Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etc ? Should Have Pacemaker Detection Facility 9. Respiration: ? Measurement Range Of 0 To 150 Breaths Per Min ? Should Have Gain Selection: ×0.25, ×1, ×2, ×4 ? Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S ? Should Have Apnea Detection Facility ? Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 10. Spo2: ? Should Have Nellcor Technology ? Should Have Measurement Range Of 0~100 % ? Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph ? Should Be Able To Select Sat Sec To Avoid False Alarm 11. Nibp: ? Must Be Of Suntech Medical Technology For Clinical-Grade Blood Pressure Measurement ? Should Have Auto, Manual, And Stat Modes Of Operation For Nibp. ? Should Have A Measuring Range Of 0-280 Mmhg 12. Should Have 2 Channels For Temperature Monitoring 13. Should Have Data Storage Capabilities: O 72 Hours Of Trend Data Storage. 2000 Sets Of Nibp Measurement Data. O 200 Alarm Events O Physiological Alarms Can Be Reviewed With 16 Sec Of Associated Waveform Along With Other Parameter Values. Even Print Out These Waveforms With Optional Recorder O 7 Leads Of Ecg Waveform Disclosure At Least Of 1-Hour O Should Have Facility To Transfer The Trend Data To Usb 14. The Monitor Should Have Drug Dose Calculator And Oxy-Crg View Screens 15. Snapshot Facility With Usb Transfer. 16.Should Have Alarm Settings For All Parameters. 17.Should Have Color Coded Alarms And Alarms Priority Can Be Configurable. 18. Should Have Cns Connectivity Of Same Make. , Fully Functional Automatic Dental Chair With Inbuilt Suction And Compressor (Brand- Confident / Chamundi) Programmable Dental Chair, Unit Fitted With Floor Mount Light With Led(Faro, Maia) Operating Light Having, On/Off And Intensity Control By Non-Touchsensor Monitor Mounting Arm High And Low Vacum Motorized Crs Suction System Autocalvable 2 Nos Beecool Ii Light Cure Cordless-1 No Modular Trolley System Over The Patient Airotor Points- 2 Nos Supreme Micromotor 35,000Rpm With Digital Display Of Speed Three Way Syringe- 1 Nos Supreme Optic Scaler With Five Scaling Tips With Endo Chuck 1 No Ss Instrument Tray X-Ray Viewer Multi Function Foot Control Comfort Dental Operators Stool Compressor Monobloc Oil-Free Medical Grade Airotor Air Compressor 1.5/2 Hp With Radiator Cooler, Condensor, Silicon Column Filter For Moisture, Dust Filter Microbial Filter Fitted On Ms Tank. , Dental Aerotor(Brand - Nsk) Push Button With Led Light , Dental Micromotor Contrangle(Brand - Nsk) Latch Type , Dental Micromotor Straight With Led Light (Brand - Nsk) , Round, Straight Surgical Bur For Straight Hand Piece Micromotor Carbide Burs(Brand - Nsk/Prima) , Round, Straight, Inverted Cone And Tapered Fissure Burs For Aerotor Diamond Fg (Brand- Dent Ark) , Rotary Files Niti Files Sx, S1 S2 F1 F2 And F3 (Brand- Dent Ark /Nsk) , Ultraound Color Doppler System (Brand -Samsung Hs30/ Ge Logiq / Mindray Mx7 (3D,4D)/Bpl) Technicalspecification 1. The Units Should Be Latest State Of The Art Digital Color Doppler With Broadband Beam Forming For Cardiac, Abdominal,Vascular And Ob/Gynapplication. The Models With Following (Or Higher) Specifications Need To Be Quoted. 2. The Machines Should Be Usa Fda And European Ce Certified And Should Be Latest In Technology And Launched In 2016 Or Later. The Manufacturing Company Should Be Iso Certified. 3. They Should Have At Least 750000 Digital Processing Channels For High –Resolution Imaging. 4. Imaging Modes : 2D, M- Mode, Color Flow Imaging, Pulse Doppler, Power Doppler, Continuous Wave Doppler And Directional Color Flow Mapping, 3D/4D Imaging Modes 5. The Machine Should Be Supplied With Dedicated 3D/4D Package 6. The Machines Should Have Facility For Simultaneous Dual/ Duplex/ Triplex Mode Display 7. Tissue Harmonic Imaging Should Be Available On All The Transducers. 9. Machines Should Be Capable Of Advanced Real Time Compound Imaging. 10. Should Have Frame Rate 1500 Fps Or More 11. Scanning Depth Should Be 40 Cms Or More 12. High Dynamic Range Of 250 Db Or More. 13. The Machines Should Have 256 Grey Shades (8 Bit) Or More. 14. One Touch Image Optimization Should Be Available In 2D Mode With One Button Automatic Adjustment Of Tgc And Receiver Gain And Compression Curve Based On The Range Of Detectable Tissue Signals. 15. There Should Be One Button Automatic Adjustment Of Doppler Prf, Baseline, Dynamic Range And Gain In Doppler Mode. 16. Pulsed Wave Doppler Should Be Available On All Imaging Transducers With Adjustable Sample Volume Size, Simultaneous Or Duplex Mode Of Operation, Simultaneous, 2D, Colour Doppler, Pulsed Doppler, High Prf Capability In All Modes Including Duplex And Triplex And Automatic Adjustment Of Scale And Baseline. The System Should Have Option To Adjust The Color Flow Mode For High Or Low Flows In One Touch. 17. Machines Should Support Broad Band/ Wide Band High Density Probes Spanning With Frequency Range From 1-20 Mhz (+/- 1 Mhz). The System Should Support Latest Technology Single Crystal Probe Or Matrix Array Probes For Better Resolution And Penetration. 18. Automatic Doppler Analysis Should Be Available With Automatic Real Time Calculation Of At Least Sixof Following User Selectable Parameters Peak Systolic Velocity End Diastolic Velocity, Mean Diastolic Velocity, Volume Flow, Time Average Mean Velocity, Time Average Peak Velocity, Resistive Index, Pulsatility Index, Systolic/ Diastolic Ratio, Acceleration/ Deceleration Times. 19. The Machine Should Have Up To 500000 Images Storing Facility And Cine Loop Review Facility With Memory Up To Minimum Of 25,000 Frames 20. The Machines Should Have Facility Of Direct Storage And Retrieval Of B/W And Color Images (Both Frozen And Cine Loop) In The Inbuilt Hard Disk Drive. In Built Hard Disk Storage Should Be Equal To Or More Than 1Tband Solid State Device In Addition With Capacity 120Gb. 21. The Machines Should Support Four Or More Transducers With Universal Ports Allowing Any Transducer To Be Connected To Any Port. 22. Machines Should Have A High Resolution Fully Articulating Non-Interlaced Flicker Free, Anti-Glare Led Display Of 21 Inches Or More With Resolution 1,920X 1,080 Or Better.In Addition, The Machine Should Have 10” Or More Touch Control Panel For Easy Access. 23. The System Should Have Image Enhancement Options Like Speckle Reduction, Spatial Compounding And Filtered Tissue Harmonics. The System Should Have Adaptive Blending Color To Maintain The 2D Resolution While Working In Color Mode. 24. Zoom Facility (Upto 8 Times Or More Magnification) With High Resolution Results And Pan Capacity In Both Real Time And Frozen Images. 25. The System Should Have Cd-Dvd And Usb Archival (Dicom And Pc Format).There Should Be 4 Or More Usb Ports. 26. Machine Should Be Offered With The Following Broadband Probes (I) Cardiac Package Along With Adult Phased Array Transducer With Frequency Ranging 1.0 - 5.0Mhz (+/- 1.0Mhz). (Ii) Convex Transducer Frequency Ranging ( C1-6Ct) Mhz. (Iii) Liner Transducer Frequency Ranging (L3-12T ) Mhz (Iv) Tvs Transducer Frequency Ranging (Ec3-10T) 27. Online 1Kva Upsand Color Inkjet Printer 28. Preference Would Be Given To Products Manufactured In India, Japan, Korea, Europe, Us. , Laproscopic Surgery Set With Hysteroscope And Resectoscope (Brand Ethicon/ Mindray Medical Pvt Ltd/ Karl Storz/ Conmed/Olympus) Unit And Camera Head The System Should Have The Full Hd Resolution-1920 X1080 Internal Medical Grade Recorder For Capturing Full Hd Videos And Full Hd Stills With Storage Capability Internal Of 50 Gb Or External Medical Grade Recorder Should Be Provided From The Same Manufacturer. System Should Have The Facility Of Controlling The Recording Device From The Camera Head. Video Scopes Can Be Connected To The Same. The Camera System Should Be Able To Provide With 1080 P Lines For Hd Resolution Image. Technical Specifications: Image Sensor: 1 Xcmos Agc: Microprocessor Controller Weight: 130Gm Focal Length: 16Mm Control Buttons: 3 (2 Of Them Freely Programmable) Input: Keyboard Input For Character Generator. Power Supply:-100-240 Vac 50/60 Hz Certified To: Iec 601-1, 601-2-18, Csa 22.2 No. 601, Ul 2601 And Ce According To Mdd, Protection Class1/Cf 2 High-Definition Medical Grade Monitor Led Crystal Display. Max. Resolution Of 1920X1080. Screen Diagonal - 27Inches Desk Top With Pedestal. Should Have The Facility Of Pip Mode. Accessories External 24Vdc Power Supply, Mains Cord, Pedestal. Certified To: En 60601-1, Protection Class Ipx 1 Led Light Source With Fiber Optic Cable Color Temperatures 6400K External Light Source Light Outlets - 1 Light Intensity Adjustment: - Continuously Adjustable Manually From Light So Should Be Supplied With Light Cable, Diameter 4.8Mm, Length 250Cm. Certified To :- Iec 601-1 & Ul 544 Ce According To Mdd, Protection Class 1/C Telescopes Forward Oblique 30 Degree Telescope, Diameter 10 Mm, Autoclavable, Length Optic Light Transmission Incorporated. Forward Oblique 30 Degree Telescope, Diameter 5 Mm, Autoclavable, Length 2 Optic Light Transmission Incorporated Co2 Insufflator Technical Specifications: Gas Flow: 0-400 L/Min Cv 625 Laprascopy Set Pressure: 0-30 Mmhg (4000Pa). High Flow Mode (0 To 40 L/Min.) Sensitive Mode Pressure 15 Mm Hg & Flow 15 L/Min For Sensitive Application Electronic Control And Colour Touch Screen, Following Data Are Displayed On Touch Screen: -Insufflation Mode. Set Value Pressure (0-30 Mmhg). Current Patient Pressure. Set Value Gas Flow (0-40 L/Min). Current Gas Flow. Gas Consumption (0-999 1). Reusable Insufflation Tube For Co2 Gas Up To Patient Body. High Flow Mode With Flow Performance Up To 40 L/Min. Easy And Intuitive Use With User Friendly Color Touch Screen 7 Inch For Easy And Precise Setting Of Set Values For Pressure And Flow And Of Insufflation Mode, As Well As For Clear Display Of Corresponding Set Values And Actual Values. Optical And Acoustic Alarm Signals In The Event Of Patient Overpressure Should Have Hose Pipe. Equipment Cart From The Same Manufacture Should Be Quoted With 4 Or More Helves Isolation Transformer Co2 Cylinder Holder Laparoscopic Instruments- Detailed Description • Veress Pneumoperitoneum Needle With Spring Blunt Stylet, Luer-Lock, Length 13 Cm & 15 Cm –2 Nos • Trocar, Size 11 Mm, Color Code: Green, Consisting Of: Trocar Only, With Pyramidal Tip Cannula Without Valve, With Insufflation Stop-Cock, Length 10.5 Cm Multifunctional Valve, Three Part Dismantel, With Washers Pack Of 10 – 4 Nos • Trocar, Size 6 Mm, Consisting Of: Trocar Only, With Pyramidal Tip Cannula Without Valve, With Insufflation Stop-Cock, Length 10.5 Cm Multifunctional Valve, Three Part Dismantel With Washers Pack Of 10 – 4 Nos • Reduction Sleeve, 11/5 Mm – 1 Nos • Reducer 11/5 Mm– 1 Nos • Telescope, Diameter 10 Mm, Length 32 Cm, Autoclavable, Variable Direction Of View From 0°-90, Adjustment Knob For Selecting The Desired Direction Of View, Fiber Optic Light Transmission Incorporated- 1 Nos •Injection Needle, Luer-Lock, Diameter 1. 2 Mm, Size 5 Mm, Length 36 Cm - 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 3 6 Cm, Right Angled, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Insert, And Outer Tube, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Long, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting- And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Alligator Jaws, Double Action Jaws, Consisting Of: Plastic Handle Without Ratchet, With Larger Contacact Area, Insert And Outer Tube, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Siz E 5 Mm, Length 36 Cm, With Connector Pin For Unipolar Coagulation, Atraumatic, Jaws With Multiple Teeth, Fenestrated, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Atraumatic, Jaws With Multiple Teeth, Fenestrated, Long, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, 2 X 4 Teeth, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle With Manhes Style With Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Bowel Grasper, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area Outer Tube, Insulated., Three Parts Dismantle 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Cleaning, Single Action Jaws, Atraumatic, Fenestrated, Curved, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet Metal Outer Sheath, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Atraumatic, Fenestrated, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Insert And Outer Tube, Three Part Dismantel. 1 Nos • Three Plece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Heavy, Double Action Jaws, Consisting Of: Plastic Handle, With Manhes Style Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel – 1 Nos • Three Plece Scissor, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Deaning, Double Action Jaws, Curved, Length Of Blades 15 Mm, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Insulated, Without Ratchet Metal Outer Sheath, Insulated Scissors Insert For Use With Trocars Size 6 Mm Three Part Dismantel 1 Nos • Single Use Scissor Insert Pack Of 10 (1X10) 1 Nos • Three Piece Laparoscopic Hook Scissors, Rotating, Size 5 Mm, Length 36 Cm, Jaws Not Crossing With Connector Pin For Unipolar Coagulati On, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Outer Tube, Insert, Three Parts Dismantel 1 Nos • Three Plece Laparoscopic Autoclavable Grasping And Dissecting Forceps, Single Action Jaws, Fenestrated, 360 Degree Rotational Sheath, Size 5 Mm, Length 36 Cm, Long, Ergonomic Metal Handle With Plastic Finger Rings With Larger Contact Area At The Finger Ring To Avoid Pressure Sores, Can Be Dismantled With The Press Of A Button. 1 Nos • Suction And Irrigation Tube, Anti-Reflex Surface With Two-Way Stopcock, For Single Hand Control, Size 5 Mm, Length 36 Cm 1 Nos • Olsen Suction Or Irrigation Tube, With Protection Basket, With Trumpet Valve, Size 10Mm Length 36Cm. 1 Nos • Dissecting-Electrode, L-Shaped, Size 5 Mm, Length 36 Cm, With Connector Pin For Unipolar Coagulation, Consisting Of: Outer Tube, Insulated Plastic Handle Electrode L-Shaped With Trumpet Handle 1 Nos • Coagulating And Dissecting Electrode, L-Shaped, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Working Length 36 Cm 1 Nos • Coagulating And Dissecting Electrode, Spatula-Sheaped, Blunt With Connector Pin For Unipolar Coagulation, Size 5 Mm, Working Length 36 Cm 1 Nos • Macro Needle Holder, Ergonomic Axial Handle With Disengage Able Ratchet, Ratchet Release On The Right Side, Left Curved Jaws, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm 1 Nos • Macro Needle Holder, Ergonomic Pistol Handle With Disengage Able Ratchet, Ratchet Release On The Right Side, Right Curved Jaws, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm 1 Nos • Dismantling Needle Holder, Ergonomic Pistol Grip With Disengage Able Ratchet, Ratchet Release On The Left Side, Jaws Curved Left, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm Consisting Of: Insert, Outer Tube, Handle 1 Nos • Unipolar Hf Cord With 4Mm Banana Plug And Length 300 Cm 1 Nos • Clip Applicator, For Use With Ethicon Titanium-Clips Lt-300 (Medium Large), Dismantling, Rotating, With Ratchet To Lock The Jaw Part Holding The Clip, Size 10 Mm, Length 36 Cm, Consisting Of: Metal Handle, With Ratchet Metal Outer Tube Insert, Three Part Dismantel, 1 Nos • Claw Forceps, Rotating, Size 10 Mm, Length 36 Cm, 2 X 3 Teeth, Single Action Jaws, Consisting Of: Metal Handle, With Manhes Style Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Claw Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, 2 X 3 Teeth, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area Outer Tube 1 Nos • Rotatable Bipolar Grasping Forceps, Rotating, Dismantling, With Connector Pin For Bipolar Coagulation, Double Action Jaws, Especially Suitable For Dissection, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet, Color Code: Light Blue Outer Sheath Forceps Insert, Three Part Dismantel. – 1Nos • Rotatable Bipolar Grasping Forceps, Rotating, Dismantling, With Connector Pin For Bipolar Coagulation, Double Action Jaws, Fine Atraumatic Serration, Fenestrated, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet, Color Code: Light Blue Outer Sheath Forceps Insert, Three Part Dismantel. – 1 Nos • Bipolar Hf Connecting Cable Length 300 Cm, Compatible With All Standard Cauteries – 1 Nos • Fascial Closure Instrument For Sub Cutaneous Ligature Of Trocar Incisions – 1 Nos • Myoma Fixation Instrument, Screw Shaped, 5 Mm. – 1Nos • Dismantling Fan Retractor, Distendable, Size 5 Mm, Length 36 Cm.- 1 Nos • High Frequency Needle, For Splitting And Coagulation, Insulated, Retractable, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 31 Cm. 1 Nos • Single Use Scissor Insert Pack Of 10 (1X10) - 1 Nos • Uterine Manipulator: Uterine Manipulator For Providing Tissue Tension Needed For Anatomical Surgery. The Manipulator Should Have Application In Tlh, Lash, Lavh And Hysterectomies For Malignant Pathologies 1 Nos • Sterilization Tray For 2 Telescopes (Same Manufacturer) • Sterilization Tray For Instruments (Same Manufacturer) Hysteroscopy Set Hysteroscope Sheath For Diagonostic Continuous Irrigation Size 6.1-6.3Mm Outer Sheath And 5.1-5.3 Mm Inner Sheath For Use With 4Mm Hysteroscope Telescope. Hysteroscope Sheath For Operative Continuous Irrigation Size 5.9-6.1Mm Outer Sheath With Operating Channel 5Fr, Leur Lock Adaptor And 5.3-5.5Mm Inner Sheath For Use With 4Mm Hysteroscope Telescope. With Stopcock & Leur Lock Adaptor And Inflow And Outflow Channe Semi Rigid Instruments For Use With Operating Hysteroscope Scissors Semi Rigid, Blunt Tips, 5 Fr., Length 36-40Cm, Single Action Jaws Scissors Semi Rigid, Pointed Jaws, 5 Fr., Length 36-40Cm, Single Action Jaws, Semi-Rigid Biopsy- And Grasping Forceps Semi Rigid, 5 Fr., Length 36-40Cm, Double Action Jaws Tenaculam Grasping Forceps Semi Rigid, 5 Fr., Length 36-40Cm, Double Action Jaws Bipolar Vaporization Electrode, Semirigid, 5 Fr., Needle Electrode Angled 90°, Length 42Cm Bipolar High Frequency, Should Fit In Most Of The Standard Electrosurgical Unit Having Bana Plug One Side, Length Should Be Not Less Than 250Cm Telescope 12, Enlarged View, Diameter 4 Mm, Length 30 Cm, Autoclavable, Fiber Optic Light Transmission Incorporated Bipolar Working Element To Be Used With 26 Fr Resectoscope Sheath: Motion By Means Of A Spring. The Thumb Support Is Movable. Return Of The Loop Is Control By The Thumb And In Rest Position The Electrode Should Rest Inside The Operating Sheath, To Be Used With 4Mm Hysteroscopy Telescope. Should Work In Saline Bipolar Cutting Loop 24 Fr Should Work In Saline Cutting Electrode 24Fr, Bipolar, Pointed, Should Work In Saline Coagulating Electrode 24Fr, Bipolar, Ball End Should Work In Saline Continuous Flow Resectoscope Sheath 26 Fr., For Bi-Polar, Including Connection Tubes For And Outflow, 2 Luer-Lock Adaptors, 26Fr, Oblique Beak, Rotating Inner Tube, With Ceramic Insulation, For Use With Working Element. Should Work In Saline Obturator, For Use With The Resectoscope Sheath. Fluid Management System (Irrigation & Suction Unit) Pressure Regulated Suction And Irrigation System For Use In Laparoscopy And Gynaecology Unit Should Have Touch Screen As User Interface. Unit Should Have Feature Of Automatically Fixing Maximum Parameters For Laparoscopy And Hysteroscopy Mode By The Choice Of Tubing Unit Should Have Feature Of Simultaneous Display Of Set Values And Actual Values Enabling User For Continuous Monitoring Of Suction And Irrigation Parameters Unit Should Have Feature Of Use Of Disposable/Reusable Cassette Tubing Set For Laparoscopy/Hysteroscopy Procedures. Unit Should Be Supplied With Glass Suction Bottle 5 Lite Unit Should Have Pressure Settings: Hysteroscopy Mode: 0-200 Mmhg Laparoscopy Mode: 100/300/500 Mmhg Unit Should Have Flow Settings: Hysteroscopy Mode: 200/400/600 Ml/Min Laparoscopy Mode: 0-1300Ml/Min Suction Pressure Regulated: Hysteroscopy Mode: 0.1-(-)0.8Bar (-80Kpa) Laparoscopy Mode: 0.1-(-)0.8Bar(-80Kpa) Power Supply: 100-240Vac, 50/60Hz Certified To: Iec 601-1, Ce Nach Mdd Certified To: Iec 601-1, Ce Acc. To Mdd Note: - All The Above Items Should Be Usfda And European Ce Certified And From Same Manufacturer For Better Compatibility And Maintenance , Integrated Electrosurgical Unit And Vessel Sealer Brand -Ensurge/ Hti Digital / Kls Martin / Enertech/Shalya Specifications For Integrated Electrosurgical Unit And Vessel Sealer 1) Advanced Electro Surgical Unit With Vessel Sealing System Have Mono Polar Cut & Coagulation, Bipolar And Vessel Sealing Technology, All Integrated In Single System 2) Type Of Display Should Be Lcd Touch Screen 3) Display Size Should Be 5” Or More 4) Unit Should Have Microprocessor-Controlled Tissue Feedback Technology. 5) The System Should Have Capability To Convert Electrical Energy To Radio Frequency Energy Thus Providing Radio-Frequency Seal 6) Number Of Tissues Sensed Per Sec Should Be 4000 Or Higher 7) Vessel Fusion System Must Be Able To Seal Artery, Veins Along With Tissue Bundle Up To & Including 7Mm In Diameter & Sealed Vessels Should Be Able To Withstand At Least 3 Times The Systolic Blood Pressure. 8) Low Frequency Leakage Should Be 50 Or Higher (In Ma) 9) High Frequency Leakage (Rf) Must Be Less Than 100Ma In Mono Polar And Vessel Sealing Mode And Less Than 70Ma In Bipolar Mode 10) Should Be Provided With Rs 232 Data Input Port For Software Upgrade Facility 11) System Must Have Recall Facility To Recall The Last Setting Used By User Before Turning Off The Power Directly Or Through User Programs. User Can Use Pen Drive With Their Setting To Recall The Setting Saved By Them. 12) System Should Have Bipolar Resection Including Under Water Cutting. 13) The System Should Be Provided With Twin Monopolar Socket (Only One Socket To Be Activated At A Time) With Independent Power Setting 14) 5 Or More Numbers Of Cutting Modes Available In Monopolar 15) Maximum Power Should Be 400W Or Higher 16) Maximum Power Of Blend Mode For Cutting With Homeostasis Should Be Not Less Than 250W 17) Fulgurate/Forced Mode, Spray Mode, Soft Mode Of Monopolar Coagulation Should Be Available. 18) Unit Should Be Supplied With 4 Or More Nos. Of Monopolar Coagulation Modes 19) Coagulation Mode Power (Monopolar) Should Be 150W Or Higher 20) Coagulation Mode Power (Bipolar) Should Be 120W Or Higher 21) Number Of Bipolar Cutting Modes Should Be Or Greater Than 5 22) Maximum Power For Ligation Not Less Than 100W 23) Maximum Power For Resection Not More Than 300W 24) Equipment Should Have On Screen Review Of Error Codes And Diagnostics. 25) System Should Have Patient Plate Contact Quality Monitoring System Giving Audio-Visual Alarm And Deactivating Output If Contact Between Patient And Patient Plate Is Not Proper To Eliminate The Risk Of Patient Burns. It Should Be Mandatory, Should Have Contact Quality Monitoring With Split Style Patient Return Electrode And Deactivates Output If Contact Between Patient And Patient Return Electrode Is Not Proper To Eliminate The Risk Of Patient Burns, Manufacturing By Same Oem 26) Auto Bipolar Start And Stop Along With User Configurable Auto Start Facility Should Be Available 27) Power Output Of Vessel Sealing System (Vss) Not More Than 150W 28) Vessel Sealing System Should Be Able To Seal Vessels Or Tissue Bundles Faster Than Any Conventional Devices (Preferably Within 2-4 Seconds) 29) Product Should Be Ce Certified (4 Digit Notified Body). 30) It Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification & Iso 9001: 2008 & Iso 13485:2003 Certified Company. 31) Warranty Of The Unit Should Be 5 Years 32) It Should Be Supplied With All Following Accessories, Should Be Reusable And Autoclavable: - O Patient Return Electrode --- 1 No. O Cable For Return Electrode --- 1No. O Hand Switching Pencil --- 1 No. O Foot Switching Pencil --- 1 No. O Double Pedal Footswitch With Toggle Function (Common/Individual For Monopolar, Bipolar And Vessel Sealing) - 3 No. O Universal Adaptor --- 1 No. O Bipolar Forceps --- 1 No. O Cable For Bipolar Forceps --- 1 Nos. O Set Of Electrode (Angled, Ball And Needle) ------ 1No. O Reusable Sealing Clamp With Cable--- 1 No. O Curved Jaw Vessel Sealer 5 Mm, 32 To 37 Cm -- 1 No. O Autoclavable Reusable Cutting Instrument – 1 No. Additional Terms & Conditions: 1. Vessel Sealing Laparoscopy Instruments Should Have Both Hand And Foot Activation Mode And Should Be Eu Ce (4 Digit Notified Body Certified) Or Usfda Approved. 2. All Sockets Should Be Of Blinking Light Type When In Use To Identify The Used Mode. 3. R.F. Frequency Should Be In Between 350-500Khz For All Modes. 4. It Should Have Bipolar Rf Scalpel Mode For Dissection & Desiccation. Rf Bipolar Scalpel Instruments Should Have Hand Control Button For Coagulation & Cut. 5. Equipment Should Be Usfda Approved/ Eu Ce (4 Digit Notified Body Certified). It Should Have Iec-60601-1- 1, Iec 60601-2-2 Safety And Des , Ctg Machine Brand - Bpl/Maestros/Bistos Specification Foetal Monitor With Display And Printer Should Have 12.1” High Resolution Colour Tft Display With Tiltable Screen For Better Viewing. Should Display Fhr, Toco, Foetal Movementin Numeric Values . Should Display 2 X Fhr And Toco Graphs In Different Colours. Should Have The Facility For Data Save With Play Back & Print Facility Should Have Facility To Monitor Information Of Last 25 Hours Should Have Special High Sensitive Watertight Probe For Better Durability Should Have The Low Ultrasound Power For The Safety Of The Foetus Should Have Automatic Foetal Movement Detection Should Have Event Marking Facility By Mother And User Thermal Printer With Minimum 152Mm Paper Width Is Essential For Broader Printouts Standard Configuration Should Be Fhr, Toco, And Foetal Movement Should Have Volume Control For Fhr Beep Sound And Alarm. Should Have Alarm Setting For Weight Should Be Less Than 4 Kg For Easy Portability. Should Have Foetal Stimulator Built In To Fhr Probe And Activation Key Should Be There On The Front Panel. Stimulation Should Be Recorded On The Recording Paper And Should Be Displayed On The Screen. Built In Rechargeable Li-On Battery For Backup Should Work With Input 200 To 240Vac 50 Hzsupply Central Monitoring System Software Upgradability Should Be Possible (Optional) Should Be Supplied With The Following Standard Accessories: Power Cord- 01 Fhr Probes – 01 Nos Toco Probe -01 Patient Event Marker Belts – 02 Nos Gel – 1 Bottle Thermal Paper- 02 No , Digital Video Colposcope Brand - Bpl/Maestros/Bistos Specification 1. Should Have Led Cold Lighting System Reproduces An Original View Of Tissue. 2. Led Lights Are Replaceable. 3. Should Have Advanced And Fast Auto-Focusing System To Ensure Clear Image. 4. Should Have Remote Capture Control And User-Friendly Keyboard Layout For One Handed Operation. 5. Should Have Electronic Green Filter That Enhances Vascular Image Display Without Compromise Of Illumination. 6. Should Have Working Distance Of 6.7 - 11.8 (170 - 300 Mm). 7. Should Have Magnification Of 1X - 36X. 8. Should Have Resolution Of 3,80,000 Pixels Or More 9. Should Have Horizontal Resolution Of > 470 Lines. 10. Should Have Field Of View Of 0.4 - 5.9 (10 - 150 Mm). 11. Signal/Noise Ratio Should Be = 50 Db. 12. Should Have Signal Output Of S-Video, Pal/Ntsc. 13. Should Have Acetic Acid And Iodine Reaction Test Timer To Precisely Detect Low/High Grade Cin. 14. Should Have Real-Time Display Of Magnification. 15. Should Have Powerful Colposcopic Findings Gallery For Comparison Analysis. 16. Should Have R-Way Evaluation Program Supports Cervical Disease Diagnosis Guidance For Clinical Users. 17. Should Have Dicom 3.0 Supportive. 18. Should Be Manufactured By An Iso Certified Company , Vessel Sealing Device For Open Surgery Shaft Length-23Cm Curved Tip (Box Of 6)(A) Curved Jaw Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology. Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A} Curve Jaw Vesselsealer B) Should Be Able To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. C) Sealing Should Withstand 3 Times Systolic Pressure. D) Scaling Length 20 Mm; Cutting Length 18 Mm, Shaft Length 23 Cm; Shaft Diameter 5 Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. Technical Specification For , Vessel Sealing Laparoscopic Surgery, Shaft Diameter-5Mm, Length-37 Cm Jaw Type Curved Jaw Double Action With Contoured Tips, Shaft Rotation 350 Degrees, Jaw Surface-Textured Ceramic Stops.Jaw Aperture-13Mm Seal Plate Length- 20.3(Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Blunt Tip Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Sealing Length 20 Mm; Cutting Length 18 Mm, Shaft Length 37 Cm D) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness:Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. E) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Instrument For Open Surgery, Instrument Length 20.6Cm-21 Cm, Curved Jaw, Hand And Foot Switching(Box Of 6). Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Exact Open Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Instrument Length Should Be 21 Cm. D) Curved Jaw In 28 Degrees, Seal Length 19.3Mm, Cut Length: 18.5Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Device Laparoscopic Surgery. Shaft Diameter-5 Mm, Maryland Jaw Curved Device Length 37Cm (Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Curved Jaw Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec B) Sealing Should Withstand 3 Times Systolic Pressure. Scaling Length 20 Mm; Cutting Length 18 Mm, Shaft Length 37 Cm; Shaft Diameter 5 Mm C) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation D) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Device For Open Surgery With Shaft Length 18.8 Cm, Jaw Type-Curved Jaw (Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Small Jaw Open Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Instrument Length Should Be 18.8 Cm. D) Curved Jaw In 28 Degrees, Seal Length 16.5Mm, Cut Length: 15.5Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Ethelene Oxide Sterlization Machine ( Brand - Steri Techno Fab/ Map Industries) 1) Eto Gas Sterilizer Should Be Fully Automatic Type With Software-Controlled Operation System For Low Temperature Sterilization Of Heat And Moisture Sensitive Medical And Surgical Items. 2) The Chamber Should Be Preferably Rectangular With Capacity Of 250 Litters Or 9 Cu. Ft. & Dimension 48”(L) X18”(W)X18”(H). 3) The Operating System Should Be Programming Logical Controller Based And Should Have Touch Screen Human Machine Interface From Where User Should Operate And Observe The Cycle . 4) The Inner Surface Should Be Smoothly Finished To Minimize Gas Deposits. 5) Manufacturer Should Provide The Test Report To Prove Conformity To Specification And Ability Of Eto Unit To Achieve Complete Pathological/Microbiological Elimination. The Test Of Report Has To Be Attached With Technical Bid Document. 6) Surface Heaters Should Mount On The Chamber For Uniform Temperature In Chamber Throughout Cycle. 7) Less Noisy And Vibration Proof Vacuum Generator Should Be Provided For Vacuum Instead Of Vacuum Pump. 8) The Machine Should Be Provided With Plc Based Automation Along With Lcd Hmi Which Allows The Operator For: (A) Change And Set The Parameters (B) Run The Cycle According To Pre-Selected Cycles. (C) Monitor Various Phases / Individual Parameters During The Process. (D) View On/Off Status Of The Various Components Of The Machine While The Cycle Is In Progress. 9) It Should Have Password Protection For Unauthorized Access & Analogue Input Of Process Pressure/Vacuum. 10) It Should Have Digital/Analogue Input For Temperature & Temperature Should Be Indicated In The Sterilization Area, By The Use Of A Temperature Sensor. 11) One Pressure/Vacuum Sensor For Display Of The Current Pressure/Vacuum, That The Load Should Be Subjected To, At All Times During The Process. 12) The Software Should Provide & Maintains Total Records Required For Process Parameters During The Sterilization Cycle. These Records Are Necessary For Meeting Ce Or En 1422 Norms Of Sterilization. 13) All The Fittings For The Accessories And The Main Vessel Should Be Fabricated From Ss 304 Stainless Steel. All The Valves Used In The Process Lines Should Be Ss 304/Brass/Teflon Construction Ball Valves. (All Standard Makes) 14) Pressure Testing And Vacuum Testing As Per Specified Standards. (1.5 Times The Working Pressure) 15) Automatic Operations As Well As Manual Operations In Case Of Technical Problems Should Be In Plc/Hmi. 16) Machine Should Not Open During Sterilization Process, It Should Be Open Only After Complete Cycle Of Sterilization. 17) It Should Be Plc Based Automation System. Plc Should Be Honeywell Or Siemens. System Should Be 21 Cfr Compliances. 18) Automation Should Be 7’’ Touch Screen Display Of Schneider Or Proface Or Equivalent. 19) The Construction Of Chamber Should Be Of Ss316 Grade Stainless Steel. 20) There Should Be Interlocks With Door Mechanism So Cycle Should Start Only After Closing Of Door. 21) Cartridge Puncture Operation Should Be Automatic Into The Chamber No Need Of Manual Puncturing. 22) In Case Of Cartridge Puncture There Should Be Alarm System. 23) One Complete Cycle Should Be Containing All Phases. Time Based Parameter Should Be Mention In Non-Editable Data Sheet. 24) Temperature, Pressure, Humidity, And Other Parameters Should Be Display In Hmi Screen. 25) It Should Be Noise Proof And Vibration Proof Vacuum Generator Should Be Provided For Vacuum Instead Of Vacuum Pump. 26) It Should Be In Built Aeration Phase To Remove Residual Gas Out From Sterile Item. 27) Pre-Requisite Sequence Phases Should Define To Run Cycle In Auto Mode. 28) Pre-Sterilization Phases Should Define To Create Proper Condition For Sterilization (I.E. Humidity& Temperature). 29) Post-Sterilization Phases Should Define To Remove Residual Gas From The Product. 30) Machine Should Have Manual Override Operating Facility. 31) Accessories Needs To Be Supplied With Machine: - ? Suitable Air Compressor Of 1 Hp Capacity. Air Compressor Should Be Oil Free And Less Noisy As Compared To The Traditional Oil-Based Compressor. ? 1 Nos Wire Mesh Type Basket For Loading & Un-Loading Of Sterilization Materials. ? Manual Sealing Machine Suitable Medical Use Sealing. Machine Should Operate On 240 V/50 Hz Operated And Make In India Product. Eto Gas Cartridge Of 1 0 0 Grams- 1 0 Nos. Eto Cartridge Should Be Of Same Make Of Machine. Bidder Must Have To Attach Msds Sheet Of Eto Gas Cartridge With Bid Document. 32) The Manufacturer Shall Have Below Listed Certification To Prove His Eligibility And Copy Of The Certificates Should Be Enclosed With The Offer. ? Iso 9001:2015 For Quality Management System. ? Ce Certificate For Eto Sterilizer & Eto Cartridge Compliance With The Requirement Of Directive Council Directive On Medical Devices 93/42/Eec As Amended 2007/47/Ec. ? Quality Management System For Medical Devices Iso 13485:2016 For Eto Sterilizer & Eto Cartridge. ? Risk Management To Medical Devices Iso 14971:2007 For Eto Sterilizer & Eto Cartridge. ? Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use - Part 2-040: Requirements For Sterilizers And Washer Disinfectors Used To Treat Medical Materials Iec 610102-040:2020 & Iec 61010-1- 040:2020. ? As Eto Gas Toxic And Carcinogenic Properties Environment Management System Certificate. ? Medical Electrical Equipment Iec– Part 1-2: Requirement For The Basic Safety And Essential Performance Of Multifunction Patient Monitoring Equipment. ? Iso 45001:2018 For Occupational Health And Safety Management System. ? Iso 20857:2010 And Rohs Directive (2011/65/Eu) On The Restriction Of Use Of Certain Hazardous Substances In Electrical And Electronic Equipment. ? Fda & Who-Gmp Certificates To Prove Standard Of Manufacturing Practice , Ot Light ( Brand - Shalya/Mattrix/Surgident) Description Of Function Led Surgical Lights Illuminate The Surgical Site For Optical Visualization Of Small Low Contrast Objects At Verifying Depths In Incisions And Body Cavities. 1. General Requirements 1.1. The Light Shall Adopt Led Technology To Create A Homogenous Light Patch Without Emitting Any Infrared Rays. 1.2. The Light System Shall Be Dual Light Heads, One Major And One Satellite. 1.3. Light Should Have Electronic Focusing From Control Panels Without Any Motorized Or Mechanical Movement Of Light Panels. 1.4. All Dome Should Have 2 Colour Led Lamps, White (Cool White) & Amber (Warm White) To Achieve High Cri And Get The Required Shade Of Light As Per Different Surgical Requirements. 1.5. High Power Leds Of 5Watts & Above Should Be Used To Provide High Lumen To Watt Ratio Which Leads To Lesser Energy Consumption And Low Heat At Surgical Area <2 Deg. 1.6. Lights Should Have Higher Watts Leds To Achieve High Lumen To Watt Ratio Which Leads To Lesser Energy Consumption And Low Heat At Surgical Area. 1.7. Pulse Width Modulation-Controlled Led Driving To Ensure Less Heating Of Led Which Increases Life Of Leds And No Change In Light Colour Output And Light Colour Temperature Throughout Life. 1.8. The Major System Shall With Automatic Illumination Control System With Sensors On The Light Head. When Some Part Of Led Is Masked By Surgeon’S Head Or Shoulders, The Remaining Led’S Will Become Brighter Automatically To Compensate For The Losing Illumination. 1.9. Light Intensity Shall Be Adjustable Between 30% -100% And Should Have Low Intensity Light For Endoscopy Mode. Light Intensity, Light Field Diameter And Color Temperature Should Be Controlled From Electronic Touch Control Panel Mounted On Light Arm And Wireless Wall Mount Electronic Touch Control Panel. It Should Also Have Provision To Control The Intensity, Electronic Focus, Depth From Sterile Field Though Capacitive Touch Control Handles. 1.10. The Light Head Shall Be Of Petalled / Winged Shape To Avoid Obstruction To Laminar Flow On Surgical Field. 1.11. The Color Temperature Shall Be Synchronized & Controlled By Either Light Head Control Panel. 1.12. The Light Shall Be Mountable To Ceiling From Single Center With 360-Degree Rotation Of All Arms. Spring Arms Shall Be Rotatable At Least 360 Degrees Around Its Own Axis. Each Dome Head Should Be Rotatable With 360 Degree At Connecting Joint With Spring Arm And At Least 300 Degrees Around Its Own Axis. This Feature Should Be Applicable With A Camera Mounted Dome Also. 1.13. The Maximum Movement Angle Of The Spring Arm Shall Be At Least Up 45°And Down 50 1.14. The Thickness Of The Light Head Shall Be No More Than 70 Mm. 1.15. Each Led Shall Be Replaceable Individually To Save Cost In Case Of Failure, Instead Of Replacing The Module With Several Leds. 1.16. The Surgical Light Should Be Complete With All Components For Celling Mount And Electrical Feed-In, Including Finalized Installation. 1.17. Detachable & Auto Cleavable Handle (3 Nos.) For Each Light Should Be Provided. 2. Technical Requirements Of Both Domes: 2.1 It Should Have 2 Colour Led Lamps, White ( Cool White) & Amber( Warm White) 2.2 The Central Illuminance Should Be 160,000 Lux 2.3 Light Field Diameter Should Be Adjustable From 150Mm To 300Mm 2.4 D10: 300Mm & D50 :160Mm 2.5 Color Temperature (K), Adjustable From 3500-5000K 2.6 Color Rendering Index Ra Should Be 95 Or More And R9 Should Be 93 Or More 2.7 Depth Of Illumination (L1+L2) As Per Iec 60601-2-41 (Ver 2003) Should Be 650Mm And As Per Iec 60601-2-41 (Ver 2008) Should Be 1200Mm. 2.8 Dimming Range Should Be Between 25-100% 2.9 Endoscopy Mode Illumination Should Be Less Than 5% Of 160,000 Lux 2.10 Number Of Led Bulbs The Light Head Should Not Be More Than 70 2.11 Led Service Life Should Be Minimum 60000Hrs 2.12 Light Head Dimension Should Be 700Mm (=/- 20Mm) 2.13 Max. Power Consumption Of All Light Sources Should Be Less Than 100W At Maximum Setting. 2.14 Power Supply Should Be 100-240V Ac, 50-60Hz 2.15 One Dome Should Be Ready For The Wireless Camera Attachment. 3.Standards • Iso 9001:2008 • Iso 13485:2003, • European Ce With 4 Digit Notified Body / Eu Ce With Eu Free Sale Certificate /Us Fda Registered . • Should Compliance With: Iec 60601-1, Iec 60601-2, Iec 60601-2-41, Certificate From Any Nabl Accredited Lab / Any Lab From Country Of Origin For Imported Brands , Suction Machine (Electrical) (Brand -Supreme / Goley) Type: Electrical Pump Type: Oil Immersed Rotary Vane Capacity: High Vacuum Voltage: 220 Vac, 50 Hz, 1 Ph Number Of Wheels: 04 (Antistatic) Air Flow: 35 Ltrs/Min Current: 1.8A Noise (Decibel): 30~35 Dba Power Consumption: 370W Weight: 25 Kgs Flow Rate: 35 Lpm Vacuum Gauge: 100Mm Reservoir Volume: 5000Ml Tubing: Non-Collapsible Suction Tubing Max Vacuum: -720Mmhg Motor:½Hp, Fhp 100% Copper Winding Rpm: 1440 Jars: Polycarbonate 2X2.5 Liters Capacity Filter: Bacterial Filter Autoclavable /Reusable Suction Machine Should Be Is I Marked , Fully Automated Biochemistry Analyser Brand (Erba Transia/ Meril) Random Access System With Stat Capability. Analytical Principle Spectrophotometry & Photometry, Turbidometry Principles. Assay Type End Point, Rate, Fixed Point, Kinetic, Ise (Optional). On Board Parameter - Present. Programmable Tests - Present. On Board Cooling For Reagent Present. Through Put - 200 Test/Hour Or More, Continuous Loading Facility. Sample Types Serum, Plasma, Urine & Other Body Fluids. Sample Volume 0-70 Micro Litres (Approx). Sample Quality Analysis, Clot Detection & Probe Crash Protection - Present. Reagent Volume 10 Microlitre To 300 Microlitre (Approx.). Total Reaction Volume 90 Microlitre To 350 Microlitre. Reaction Cuvettes - Permanent Glass Cuvettes With On Board Laundry. Possibility Of Replacement Of Individual Cuvette. Photometric Range 0-3.0 Od. 15. Wavelength-340-800 With Minimum & Standard Wavelengths (340, 405, 505, 546, 578, 600, 700 Nm) Calibration Autocalibration, Cooled Calibration Position, History Of Graphical Calibration Data Stored. Quality Control At Minimum 4 Level Qc Plot Westgard Rules, Twin Plot, Levey Jennings Graph, Cooled Qc Position. Data Storage Of Patient Present Proper System Of Storage Minimum Water Consumption. Warranty 5 Years Warranty Power Back Up Facility For Instrument. Autopipettes To Be Provided With Instrument 10 Micro Litre (Fixed) 01 Nos. 1000 Micro Litre (Fixed) 01 Nos. 0-100 Micro Litre (Variable) 01 Nos. 0-500 Micro Litre (Variable) 01 Nos. 100-1000 Micro Litre (Variable) 01 Nos. Demo Kit With Instrument Reagents Kits Provided With Instrument: Creatinine, Urea Uric Acid, Triglyceride, Sugar Cholesterol, Tp, Albumin, Sgpt, Sgot, Alkaline Phosphatase, Bilirubin Instrument: Usfda Registered And Ce Ivd Approved , Cbc Machine Brand -(Accurex / Erba/ Meril) Measurement Principle Electrical Impedance For Counting Rbc Wsc & Plateletscolorimetric Estimation Of Hgb At 540 Nm Parameterswbc, Ly#, Mid, Gr, Ly%, Mid%, Gr, Rbc, Hgb, Hct, Mcv, Mch, Mchc, Rdw-Cv, Rdw-Sd, Plt, Mpv, Pdw, Pct, P-Lcr, P-Lcc Throughput- 60 Samples/Hour Micro-Aperturewbc: 100 ?M Rbc/Plt:68 ?M Sample Typewhole Blood Or Pre-Diluted Sample Sample Volumewhole Blood (Venous Blood): 10 ?Lpre-Diluent (Capillary Blood) : 20 ?L Chamberdual Chamber: Rbc/Platelets & Wbc/Hgb Reagents- 3 Reagent System: Diluent, Detergent & Lyse (Non-Cyanide) Measurement Range Linearity Range Acceptable Limits Wbc0x10/L-10.0×109/L<= Plus/Minus 0.3 * 10 ^ 9 / L 10.1×109/L-99.9×109/L 0X102/L-1.00×102/L <= (Plus/Minus 5)%<= Plus/Minus 0.05 * 10 ^ 12 / L Rbc 1.01X102/L-9.99X102/L<= (Plus/Minus 5)% Quality Control - 4 Qc Options: L-J, X-B, X-R & X Qc Graphs Plotted With 31 Data Points Data Memory - Upto 100,000 (With Histogram) Display - 10.4 Inch Color Lcd With 640 * 480 Resolution Printer Built-In Thermal Printer Interface:Support Rs-232C, Standard Network Port And Usb; Keyboard And Mouse Operating Environment - Temperature: 15°C-35°C Electrical Specification-Fuse Specification: 250V/3A Humidity: = 85% Rh Frequency: 50/60 Hz Low: 1 X 3Ml/Normal: 1 X 3Ml/High: 1X3 Ml , Sthetoscope Brand- Bpl/Littman , Pulse Oxymeter Brand - Dr Trust /Beurer/ Bpl Specification Finger Chamber With Smart Spring System Accommodates A Wide Range Of Finger Sizes Pop-Up Menu To Setup Alarm Limits For Spo2 And Pulse Rate Low Battery Indicator Pule Rate: Yes Auto Power-Off: Yes Bright, Large Display For Better Visibility In Daylight Anti-Movement Feature Sturdy, Portable And Light-Weight Very Easy To Operate With Single Switch Operation Warranty ( Only Checking Warranty ) , Nebulizer Machine ( Brand -Bpl/Dr Trust) Operation Mode Table Top Size Compact Application Clinical Purpose, Hospital Medicine Cup Capacity 50 Ml Particle Diameter 1-5 Um , Pns ( Pereferal Nerve Stimulator For Nerver Block) Brand- B Braun / Vygon Sas/ Stimuplex Hns/2 Should Be Suitable To Identify Peripheral Nerves And Giving Percutaneous Stimulation In Neuro Muscular Block. - Should Have A Percutaneous Monopolar/Bipolar Stimulating Handle For Localization Of Nerves Without Puncturing The Nerve Which Should Be Autoclavable. - Should Have Selectable Stimulation Intensity Ranging From 0-60Ma In Steps 0.1Ma With Stimulating Handle And Stimulation Impulse Width From 0.3Ms, 0.5Ms And1.0Ms - Should Continuously Measure & Display Actual Current Passing Through The Patient And Selected Current -Should Have Pause Function To Interrupt Stimulation Without Delivering Impulses Test Function -Should Automatically Switch Off With A Acoustic Warning If Not Operated Over A Period Of 20 Mins -Should Have Lcd Display For Stimulation Current, Impulse Pattern, Pulse Width, Impulse Amplitude. - Should Have Analog And Digital Display Of Selected Current And Actual Current. - Should Have Membrane Touch Pads For Choosing Stimulation Function -Should Be Small (Pocket Size) & Light Weight. Should Be Ce Certified Or Usfda Certified , Nerve Locator With Needle Brand- B Braun / Vygon Sas/ Stimuplex Hns/2 Separate Output For Nerve Stimulator - Mapper And Locator For Safety. Automatic Switch Over From Mains Power Adaptor To Rechargeable 9Vbattery With Low Battery Warning Indicator. Feather-Touch Keypad For Easy Operation, Simple Setting And Extended Reliability. Variable Current Range As Per The Selected Mode(Impedane:0 To 5 Kohm). User Programmable Pulse Width And Frequency. Alphanumeric Lcd Display With Back Light. Automatic Shutdown For Power Saving. Audio And Back Light On-Off Option. Alarm: Audio-Visual-Alarm Is Activated If Flow Of Oxygen Falls Below 1Lpm. , Percussion Hammer Ss 304 , Tuning Fork 128 Hz Satinless Steel , Laryngoscope A Laryngoscope Is A Device Used In Medical Procedures To Visualize The Trachea By Inserting A Blade With A Small Light Into The Patients Mouth , Oxygen Concentrator Brand- Philips/Bpl/Deck&Mount 1. Flow Rate :-0-5L/Min 2. Purity 93+3% 3. Outlet Pressure(Mpa):-0.04-0.07 4. Sound Level :-<50 Dba , High Flow Nasal O2 Cannula (Brand- Drager / Niceneotech ) High-Flow Nasal Oxygen (Hfno) Therapy Delivers Heated And Humidified Oxygen At High Flow Rates (Up To 60 Liters Per Minute) Through A Nasal Cannula , Electric Needle And Syringe Destroyer Hub Cutter Stainless Steel With Auto-Cut Protection , Clinical Thermometer(Digital) , Medical Labrotary Refrigrator ( Brand- Remi / Vav Intruments) Capacity 600 Litres Temperature Range 2°C To 8°C Internal Configuration Adjustable Shelves And Storage Bins For Optimal Space Utilization Cooling Type Uniform Cooling For Consistent Temperature Distribution Display & Controls Digital Display With User-Friendly Controls Power Supply Energy-Efficient Performance , Refrigrator Domestic Single Door Godrej/ Kelvinator/ Bluestar Capacity 200 Litres To 265 Liters Temperature Range 2°C To 8°C , Wieghing Scale Mannual , Knee Hammer , Sahli,S Heamoglobinometer , Artery Forcef Staright 6 (Brand - Jj Instrument) , Double Hook Retractor Standard Size (Brand - Jj Instrument) , B.P Handleno 3 (Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 4 Mosquito(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 6 Medium(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 8 Long(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 9 Long(Brand - Jj Instrument) , Allies Forceps Big (Brand - Jj Instrument) , Allies Forceps Medium (Brand - Jj Instrument) , Allies Forceps Small (Brand - Jj Instrument) , Mayo Scissior Str 5 ½ Sttilette Edge(Brand - Jj Instrument) , Mayo Scissiorcvd 6 ¼ Sttilette Edge(Brand - Jj Instrument) , Scissors Straight 6 Medium(Brand - Jj Instrument) , Scissors Straight 5 Small(Brand - Jj Instrument) , Scissors Straight 8 Big(Brand - Jj Instrument) , Steinman Pin Introducer Ss(Brand - Jj Instrument) , Towel Clip 6 Big(Brand - Jj Instrument) , Towel Clip 4 Small(Brand - Jj Instrument) , Wire Cutter 9 Standard Size(Brand - Jj Instrument) , Detnal Wire Standard(Brand - Jj Instrument) , Langenbeck Retractor Medium(Brand - Jj Instrument) , Langenbeck Retractor Small(Brand - Jj Instrument) , Langenbeck Retractor Big(Brand - Jj Instrument) , Cats Paw Retractor Standard Size(Brand - Jj Instrument) , K-Wire Cutter With Tungsten Carbide Tip 7 Standard(Brand - Jj Instrument) , Hintermann Distractor Medium(Brand - Jj Instrument) , Mippo Wire Passer For Long Bone Large(Brand - Jj Instrument) , Wire Bender Standard Size(Brand - Jj Instrument) , Kocher Clamp 8 Standard Size(Brand - Jj Instrument) , Glucometer (Brand-Dr Trust / Dr Morphen/Accucheck/Accurex) Fast Result In 5 Seconds Small 0.5Ul Blood Sample Size Large Memory. 10 Lancets Minimum Blood Sample: 0.5 Microlitre ; It Features A Large Display Screen That Can Store Up To 300 Test Results , Vortex Mixture (Brand -Remi /Borosil/ Benchmark) Type Of Product Cyclomixer Shaking Movement Orbital Orbital Diameter (Mm) 4 Motor Type Shaded-Pole Motor , Bio Saftey Cabinet Type-Ii A Microflow (Brand - Microflow / Thermofisher) Specification Material Of Construction (Main Body) Crca/Gi Powder Coated/Stainless Steel 304 Material Of Construction (Work Table) Stainless Steel 304 Dimensions External (Wxdxh) -1950 X 900 X 2250 Mm Internal (Wxdxh) - 1830 X 610 X 610 Mm Average Air Velocity - 90 ± 20% Fpm Hepa/Ulpa - Efficiency 99.997%/99.999% Class Level - Iso 3/5 (Class 100) Noise Level - 65 ± 5 Db Electrical - 230 V, 50 Hz, Single Phase Special Features - Motor Driven Front Door, Alarm, Hepa Filter Blockage, Timer For Uv Light, Power Socket Inside The Cabinet Pressure Sensor Monitoring, Digital Airflow Verification, Interior Eye Level Display, Display Parameters Including Down Flow Air Velocity, Total Operating Hours. Standards Us Fed Std 209 E, Iso 14644-1, Iest-Rp-Cc-002-2, Bsi Certifications- Ce & Iso , Co2 Incubator (Brand - Remi / Thermofisher) Specification Chamber Volume (150 Liters) Sensor Infrared Co2 Heating Method Air-Jacketed, Pid Control Co2 Range 0~20% V/V Co2 Control Resolution ± 0.1% (Ir Sensor) Temperature Range Rt+5~55°C Temperature Stability ± 0.1°C Humidity Method Natural Vaporization > 95% Co2 Recovery (Door Open 30S, Recovery To 5%) = 3 Min Temperature Recovery (Door Open 30S, Recovery To 37°C) = 8 Min Shelves 2 3 Interior Dimension (Mm) (W X D X H) 400 X 450 X 500 480 X 530 X 610 Exterior Dimension (Mm) (W X D X H) 590 X 687 X 790 670 X 767 X 880 Supply:220-240 Volts, 50 Hz Single Phase , Binocular Microscope - Olympus( Model Ch21i) / Magnus (Model- Pzb 22) (Specification) Optical System: - High Contrast Finite Colour Corrected Optical System Magnification:- 40X To 1000X Visual Magnification. Stand: Aluminium Die-Cast Stand With Hand Rests For Enhanced Comfort And Stability. Observation Head: - Sidentopf Binocular/Trinocular Head, 360° Rotatable, Interpupillary Distance 53-75Mm, With Dual Diopteric Adjustment. Eye-Piece: - Wide Field 10X F.O.V 22Mm, Anti-Fungal & Anti- Reflection Hard Coated (Optional 10X/18Mm). Nosepiece: - Reverse Angle Quadruple Nosepiece (Ball Bearing Type) With Precise Click Stops. Objective: - Qusp Series High-Contrast Flat Shield Plan Din Achromatic Objective 4X, 10X, 40X (S) And 100X Oil, (S), Anti-Fungal & Anti-Reflection Hard Coated. Mechanical Stage: - Rack-Less X Axis Double Plate Stage, Size 190 X 125Mm (+-5Mm) With Cross Travel 90 (X) X 50Mm (Y) On Ball Bearing With Co-Axial Controls. Hard Coated Surface For Scratch Resistance. Double Specimen Holder Clip. Focusing Control: - Co-Axial Coarse And Fine Focusing On Gear Systems For Smooth Operation. Fine Adjustment 0.2Mm/Rotation With Maximum 2-Micron Scale Increment. Condenser: - Sub-Stage Moveable Abbe Condenser, Centerable, Na 1.25 With Aspheric Lens. Iris Diaphragm And Special Frosted White Filter, Swing-In, And Swing-Out Filter Holder. Light Source: Led 3.5W 3V Illumination With Variable Illumination Control Universal Power Supply 110V-240V, Ce Approved. Supply With: Power Cable, Immersion Oil, Spare Bulb (In Led Only) User Manual, Vinyl Dust Cover, Cleaning Cloth, And 01 Units Fuses Optional Accessories: - Wooden Carrying Case, Pointers & Micrometre Reticules , Penta Head Microscope(Brand- Micron/Magnus/Weswox) Optical System- Infinite Optical System Viewing Head Inclination 30 Degree, Ipd: 48-75. 01 Piece Trinocular Head, Inclined At 30°, 360° Rotatable, Phototube With 100:0/50:50 Light Split With Sliding Prism. 04 Piece Compensation Free Binocular Head, Inclined At 30°, 360° Rotatable With Diopter Adjustment. Eyepiece-10 Pairs Of Wide Field Eyepiece Wf10x/22Mm Nosepiece- Inverse Quintuple Nosepiece. Objective Plan Achromatic Objective 4X Plan Achromatic Objective 10X Plan Achromatic Objective 20X Plan Achromatic Objective 40X Plan Achromatic Objective 100X Condenser - Swing Out Condenser N.A.0.9/1.25 Focusing-Coaxial Coarse And Fine Adjusting System With Tightness Adjustment And Upper Limited, Coarse Adjustment Range 30Mm. Fine Adjustment Precision: 0.002Mm Attachment- Multi Head Attachment And Support Stand. Stage- Ceramic Coated Double Layers Mechanical Stage Of 185X142 Mm With Capacity To Hold Two Slides At A Time With Slide Catcher On Left And Motion Control On Right Hand Side Illumination- External Illumination, Led 12V 100W Pointer - Multi Colored Ponters With Intensity Controllable Led Colored Indicator (Blue, Green And Red Led) Pointer 360 Rotatable, Brightness Adjustable, Arrow Control Sticks And Color Selection Dial. Video Adapter C Mount 0.5X Camera - 8Mp Hd Camera 4K Resolution With Removable Hd Card With Sd Card And Compatible Software. Display-43 Inch Hd Display Connected To Penta Head Camera For Live Display With Suitable Stabilizer For Display. Certifications - Ce(Notified), Ios 9001 (Iaf Accredited), Ios 13485 Warranty: 1 Year , All In One Pc ( Brand- Hp/Dell/Lenovo) All-In-One Pc 13Th Gen Intel Core I5 27 (68.6Cm) Fhd 16Gb Ram, 1Tb Ssd, Intel Uma Graphics, 710 White Wireless Keyboard And Mouse Combo (Windows 11 Home, Mso 21, Shell White, 6.72 Kg) 27-Cr0407in , Desktop ( Brand- Hp/Dell/Lenovo) 13Th Gen Intel Core I5 27 (68.6Cm) Fhd 16Gb Ram, 1Tb Ssd, Intel Uma Graphics, Wired Keyboard And Mouse Combo (Windows 11 Home, Mso 21) 27-Cr0407in , Air Conditioner( Brand- Hitachi/ Bluestar/ Daikin/ Carrier) Ac 1.5 Ton05star Smart Inverter Ac With Installation & Extra Wire /Pipe , Air Conditioner( Brand- Hitachi/ Bluestar/ Daikin/ Carrier) Ac 2 Ton05star Smart Inverter Ac With Installation & Extra Wire /Pipe , Lithium Battery 1500Wh Battery 48W 120Ah ( Brand- Luminous /Amaron) , Executive Premium Office Chair, Leather “Adjustable Arms Ergonomic Chair Must Behigh Back ( Brand- Godrej) , Office Table4x3 Feet( Brand- Godrej) , Mid Back Office Chiar ( Brand- Godrej) , Revolving Stool ( Brand - Aliza /Godrej) 3 Leg Ss Top Powder Coated Thicknessminimum- 14 Gauge , Steel Almirah W X H X D: 91.44 Mm X 197.866 Mm X 485.140 Feet For Office Use(Brand- Godrej) , Xerox Machine (Hp/Canon/Ricoh) Print Duplex, Copy, Scan, A3 Black And White Laserjet Printer, Enterprise Departments/ Distributed Workforce, Laser Printers Print Speed Is Up To 22 Pages Per Minute (Ppm) For Black And White Printing , Imcubator Electrical 23 Lts Thermostat , Centrifuge Machine Clinical ( Brand - Remi /Benchtop) , Salters Baby Wieghing Machine , Oto Scope , Chloroscope , Horrock,S Appratus Portable , Sound Level Meter Decible Meter With Lcd Display , Water Depth Sampler , Vaccine Carrier , Mosquito Catching Kit , Craft Water Testing Kit
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
11.
Power #10403772 Price Bid
Tender For Construction Of 2 Nos Ais Bays With Extension Of 132Kv Main Bus For 132Kv Sonik-Sarain Katiyan Double Circuit Line At 132Kvs/S Sonik, Unnao - 110 V DC Distribution Board 3 Bay Marshilling Kiosk for 132 kV Switchyard 4 40mm MS Rod for Main Earthmat 5 40mm dia, 3 Mtr MS Earth Electrodes 6 MS Flat of Size 75 x 10mm 7 MS Flat of Size 50 x 6mm 8 MS Flat of Size25 x 6mm 9 70kN Antifog Disc Insulators 10 Hardware fittings 11 Single Tension Fittings Suitable for 12 ACSR Moose 13 Single Suspension Fittings Suitable for: 14 ACSR Moose 15 PG Clamps suitable for 16 Moose/ Moose 17 Moose / Panther 18 Panther/Panther 19 Fire fighting Equipment including installation 20 Portable AFF mechanical foam type Fire Extinguisher complete with initial charge hose pipe and all other accessories and fittings as per IS 1024 trolley mounted 50 lit. cap. 21 Supply of following fire extinguisher carbon dioxide (CO2) as per IS Specn. No. 2878/1986 22 22.5 Kg. 23 9 Kg. 24 4.5 Kg. 25 Supply of sand buckets as per tech. Specn. 26 CBL Tray galv . Lot 27 GI perforted Cable Tray (225/250mm) 28 GI perforted Cable Tray (75mm) 29 3 Mtr long Earthing/Discharge Rod having 10 Mtr, 25 sq. mm. copper cable 30 Digital Multimeter (4 1/2 digit) (Motvani or equivalenet make) 31 415 V AC Lighting DB 32 Erection of various structures & equipments 33 Erection of main and auxiliary structure consisting of columns, beams, peaks, masts etc. and auxiliary structures required for installation of Bays BKR, ABR, APR, YMR, AKR, BBL, BTI, BCT, ALP etc. including shifting of all material i.e. structure parts nuts, bolts washer etc. from store to site of erection, erection of structure as per drawings and practices using flat and spring washer with each bolt. Matching of holes, cutting, matching of member if required shall also be done by the contractor without any extra cost to complete the work satisfactorily. All material to be erected shall be supplied by the UPPTCL free of cost but all men, material and T&P required for satisfactorily completion of work shall be arranged by the contractor at his own cost. 34 Erection of Equipments :- Erection of following equipments as per instruction manual of various equipment and technical specification including shifting of material/equipment from store to erection site including all other associated work to complete the job satisfactorily :- 35 145 KV C.B. 36 145 KV C.T. with JB 37 145 KV P.T. with JB 38 120 KV LAs. 39 145 KV Bus Isolator. 40 145 KV Line Isolator. 41 145 KV Tendom Isolator. 42 145 KV Post Isolator. 43 132 KV Control &Relay Panel 44 Control cable laying & interconnection 45 Laying of following sizes of control cable in the cable trench from control relay panel to various equipment/marshalling boxes/JB etc. in switchyard as per cable schedule, its saddling at every 75mm. distance with MS saddles of size 25x3mm. including carriage of cable drum from store to laying site & shifting back to store and all other associated works to complete the job satisfactorily as per technical specification. 46 10 x 2.5 mm. 47 6 x 2.5 mm. 48 4 x 2.5 mm. 49 2 x 2.5 mm. 50 Interconnection & termination of the above laid control cables between Control and Relay Panels & erected equipments i.e. СВ , СТ , СТ Junction Box, PT, PT Junction, box,ISO Box. Including making necessary holes in Gland Plates or Boxes whereever required along with supply of Cable glands of appropriate size and providing of Ferrules for each core of the cables & its termination with crimping type Copper Lugs alongwith preparation of interconnection Drawing and Commissioning of the Panel/ Feeders in co-ordination with T&C Wing including providing 02 sets of Hard Copies of as executed Interconnection Drawing including associated works required for the satisfactorily completion of the Job as per technical specification. 51 Bus bar and jumpering 52 Stringing of 132 KV Main bus bar 3 phasewith Twin ACSR Moose conductor including fitting oftension clamp, hoisting ofDisc Insulator, cutting of conductor and also shifting of all materials from store site.(1 section =24Mtr) 53 Jumpering of newly erected equipmentswith ACSR Moose/panther conductors work includes jumper cutting,making& tightening of jumpers with specified tools. 54 Earthing details 55 Laying of Earth Mat in Extended 132 KV Switchyard of 132KV S/S Sonik, Unnaoalong with connecting the newly Laid Earth Mat with Existing Earth Mat columns including cost of all labour, T&P, Misc. Consumable material etc. for proper completion of work. 56 Laying of 40 mm dia MS round bar, 700 mm below the ground level along with shifting of MS round bar from store to work site including cutting straightening welding painting excavation of trench etc. along with back filling of excavated trench after laying earth mat 57 Fabrication of 3 Meter long Electrode with 40 mm dia MS Round Bar having 150 mm long conical shape and then its pierced vertically, inside the Ground with top 700 mm below ground level including shifting of MS Round Bar from store to Switchyard. 58 Making of 150 mm long Lap Joint of above laid 40 mm dia Round bar by due cutting, Straighteningwelding on both sides and painting then black bituminous paint. 59 Making of 150 mm long Lap Joint of above laid 40 mm dia Roundbar to connect with existing Earth Mat of the sub station by due welding on both sides and painting each joint with black bituminous paint. 60 Making of cross Joint of abvoe laid 40 mm dia MS Round Bar, 700 MM below Ground Level by due welding at all 4 corners including providing & welding of suitable size MS Angle Piepe on opposited corners. 61 Making of End Joint of above laid 40 mm dia MS Round with Top of Vertically Pierced MS Electrodes, 700 mm below Ground Level by due weldingand painting each joint with black bituminous paint. 62 2 point earthing of structure and equipments with 75x10 and 50x6 mm MS flats by digging 0.7 meter deep trench in earth from equipments to substation earthmat in X & Y axis which includes providing, cutting, welding and bending of MS flats as well as shifting of materials from store to site.All materials including MS flat to be provided by contractor. 63 MS Flat 50x6 mm 64 MS Flat 75x10mm 65 MS Flat 25x6mm 66 Painting of earthing strip of various size with 1 coat of red oxide and 2 coat of Bus green ISI paint including vertical suppport. Paint to be provided by contractor. 67 MS Flat 50x6 mm 68 MS Flat 75x10mm 69 MS Flat 25x6mm 70 Making mesh earthing(AS per drawing) for 120KV LA for 132KV Sarai Katiyan-I & II. 71 Miscellaneous work 72 Installation, testing, and commissioning ofoutdoor 415V AC Lighting Distribution Board (LDB) at Sonik for proper functioning , as per instructions of the Engineer-in-Charge. All required manpower, tools, testing equipment, and earthing of the LDB shall be in the contractors scope. 73 Installation, testing, and commissioning of Bay Marshelling Kiosk at Sonik for proper functioning , as per instructions of the Engineer-in-Charge. All required manpower, tools, testing equipment, and earthing of the Marshelling Kioskshall be in the contractors scope. 74 Obtaining No objection certificate from office of Electrical safety Directorate, Lucknow for first time energization of 02 Nos. 132 KV Bays with extension of 132 KV Main Bus. (including payment of fee as per challan) 75 Erection of SAMAST Energy Meter and Data communication work 76 Installation of new 3P4W, 0.2s accuracy class interface Energy meters (Main & Check) 77 Necessary interconnection from data transmission of already installed SAMAST compliant meters to LAN switch upto DCU/Gateway and all other H/W, S/W. 78 Installation of communication cable (CAT-6 alongwith necessary hardware wherever required in between energy meter to LAN switch to SDH equipments upto DCU/Gateway and all other H/W, S/W. 79 Installation and commissioning of meter cubical/DCU/SW 80 Providing & fixing of 150 Watt LED street light luminaries fittings of Philips/Compton/Havells make with IP 65 rating in single piece die cast aluminum alloy housing with pot optics reflector & toughened clear glass cover with frame for lamp compartment including cable termination. 81 Providing & fixing of HI SL pole bracket duly made of 40mm dia 1.2 Mtr. Long B Class pipe and bent at one end by quarter circle in 1.0 Mtr. at an angle of 300 for fixing of 150 watt LED street light luminaries fittings on M.S. round Pole with the help of M.S. Clamps.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
Uttar Pradesh View Result →
12.
Heavy Industries and Public Enterprises #10390733 AOC
Vertical Extension & Other Development Works at Academic Block Annex-2 Palayad Campus, Kannur University, Kannur, Kerala under PM-USHA scheme- 1 Civil work -General Structural work 2 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge25 mm average thickness 3 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter 4 Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. 5 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar 6 Core Cutting of RCC slabs(12cm Maxi.thickness) by using mechanical core cutting equipment of required diameter of the pipe in full depth etc to the satisfaction of engineer in charge including all cost and conveyance materials and labours charge etc complete (dia 80-200mm) 7 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 8 Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work ( Payment shall be made on the cross sectional area of R.C.C. or R.B work) as per direction of Engineer-in-charge. 9 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within alead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia 10 Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock 11 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 12 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 13 Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) 14 Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. 15 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 16 Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum). 17 Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 18 Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 19 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 20 Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts 21 Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) 22 Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges 23 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. 24 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more 25 Block work & Finishing Work 26 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 27 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 28 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) 29 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 30 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) 31 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 32 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats 33 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 34 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work 35 Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections. 36 Teracotta Clay Jali work, For Building work, minimum 7.5 cm thick as per approved design and pattern of Engineer in charge in super structure above plinth level upto floor V level with cement mortar 1:4 (1 cement : 4 coarse sand) with neat finish, polishing work all complete. 37 Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with Zinc coating of 120 gms/ (both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wallwith suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre.The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channelof 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufactures specification and direction of engineer in charge all complete.75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG),plaster board conforming to IS : 2095 : (part 3) 1996 (Board with BIS Certification marks) 38 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 39 For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 40 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides 41 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness 42 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm 43 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in- charge. 44 Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm 45 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 46 Joinery 47 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 48 Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer- in-charge. 49 Providing and fixing factory made uPVC white colour casement/casement cum fixedglazedwindowscomprisingofuPVCmulti-chamberedframe,sashand mullion(whereeverrequired)extrudedprofilesduly reinforcedwith1.60+/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriatedimension,EPDMgasket,stainlesssteel(SS304grade)friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mmsizeforfixingframetofinishedwall,plasticpackers,plasticcapsand necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)Note: For uPVC frame, sash and mullion extruded profilesminus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm). 50 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness 51 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood 52 Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin - charge using Anjili/ Jack wood 53 Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc 54 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 55 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm 56 Providing and fixing CP Brass Handle 450mm in all types of doors with the necessary fittings and arrangements all complete. 57 Providingand fixing chromium plated brass handles with necessary screws etc. complete:200 mm 58 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality, with necessary screws etc complete as per direction of Engineer- in- charge. 59 French spirit polishing:Two or more coats on new works including a coat of wood filler 60 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6 mm for diagonal braces and central cross piece 61 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1800X2250 mm. 62 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1000X2200 mm. 63 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately) 64 Providing and fixing SS H handle having min 45 cm length in toughed glass door including all necessary screws etc. complete. 65 Providing and fixing of glass door SS Patch Lock with out handle in toughened glass door including all necessary screws etc. complete 66 Fixing 12 mm thick frameless toughened glass partition of approved brand and manufacture, including top & bottom fixing arrangement and making necessary holes etc. for fixing required fittings, all complete as per direction of Engineer-in- charge. 67 Providing and fixing 3M Fasara frosted etching film of thickness 25 microns self- adhesive of approved colour, shade, and quality with cutting as per approved design and pattern, including cleaning of glass and making surface smooth for fixing of film to the surface, all completed as per the direction of the engineer in charge. 68 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover 69 Providing and fixing ball bearing for rolling shutters. 70 Sanitary and CP Fittings 71 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 72 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 73 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 74 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap 75 Providing and fixing ceramic urinal partitions of standard size as per direction of Engineer-in Charge and of approved shade 76 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore 77 Providing and fixing uplasticised PVC connectionpipe with brass unions: 30 cm length15 mm nominal bore 78 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:150 mm diameter 79 Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore 80 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore 81 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm 82 Providing and fixing white vitreous china laboratory sink with C.I brackets, C.P. brass chain with rubber plug 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required:Size 600x450x200 mm 83 Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in- charge. 84 Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. 85 Flexible pipe32 mm dia 86 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with C.P. brass screws and washers complete. 87 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 88 Providing and fixing SS grating of approved quality and colour. Rectangular type with openable lid150 mm nominal size square 100 mm diameter of the inner hinged grating. 89 Providing and fixing disabled friendly bathroom kit with all accessories including wash closet with soft close seat cover and cistern with twin flush setting, wash basin of min dimensions 510mm x 400mm with all necessary fittings including Angle cock, Connection pipe, waste pipe, Spatula Lever basin mixer, Wall mounted 600mm long, Wall mounted grab bar 600 mm long and wall mounted hinged rail 750 x 750, Health Faucet with angle cock. Recommended Makes : CERA , Hindware, Jaguar or equivalent . 90 Plumbing 91 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall32 mm nominal outer dia pipes 92 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall40 mm nominal outer dia pipes 93 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall50 mm nominal outer dia pipes 94 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes 95 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes 96 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore 97 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore 98 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore 99 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore 100 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall 101 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall 102 Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall 103 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow 104 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee 105 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63x50 mm dia Reducer 106 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 107 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 6Kgf/cm2 108 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2 109 Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall 110 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend 111 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee 112 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl 113 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia End cap 114 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow 115 Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall 116 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend 117 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee 118 Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl 119 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap 120 Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow 121 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer 122 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore 123 Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 124 Yard Plumbing 125 Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2 126 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling 127 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):With common burnt clay F.P.S ( non modular) bricks of class designation 7.5 128 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Single pushfit Coupler110 mm 129 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionBend 87.50110 mm bend 130 Tile and Granite work 131 Providing and laying Matt Finished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 1200 x 600 mm. 132 Providing and laying Matt finished Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, ofapproved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 1200x600 mm 133 Providing and laying Anti Skid matt vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. 134 Providing and laying premium vitrified bathroom wall tile in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. 135 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm 136 Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining ( veneer work), backing filled with a grout of 12 mm thick average in cement mortar 1:3 ( 1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 ( 1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade ( To be secured to the backing by means of cramps, which shall be paid for separately).Area of slab over 0.50 sqm 137 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade. Area of slab over 0.50 sqm 138 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 139 Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work 140 Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 141 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 142 Providing and fixing 12 mm thick gang saw cut, mat /rough finished granite, machine cut for steps, ramps or inclined plate form with raking and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 143 Structural steel 144 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 145 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 146 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 147 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 148 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 149 False ceiling 150 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board 151 Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit. 152 Rainwater Harvesting ,Fire Tank,Septic Tank 153 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock 154 Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock 155 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 156 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 157 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level 158 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 159 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm 160 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm. 161 Supplying and fixing C.I with frame for manholes: 600mm x 600mm ( heavy duty) the weight of the cover and frame shall not be less than 208 kg 162 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 163 Providing and placing on terrace (at all floor levels) Stainless Steel 304as per IS 5522:1992 of capacity 5000 Litreswith suitable fixing arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 164 Providing and fixing of Fire Rated door 1200x2100mm- Hollow metal fire doors at all levels from ISO 9001-2015 certified Manufacturer. Fire door should be as per NFPA 80 and NFPA 252. All fire doors should be tested at UL for 120 minutes and should pass both UL10B and UL10C. Doors shall be made from pressed galvanized steel confirming to IS277 as per following specification.Frame:Door frame shall be single rebate grooved profile of size 125 x 55 mm made out of 1.6 mm (16 gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self-tabs. Frames to have in build grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate ANSI UL labeled hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff and the gaps shall be sealed with silicon sealant.Shutter: Door leaf shall be 46 mm thick fully flush double skin door without vision lite. Door leaf shall be manufactured from 1.2 mm (18 gauge) minimum thick galvanized steel sheet.The infill material shall be resin bonded honeycomb core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI standard. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf.Door and frames shall be finished Pure Polyester Powder coated and shall have passed minimum 500 hours of salt spray test.Vision glass: The glass shall be 5mm clear fire rated glass of equal rating and not exceeding size of 114 sq. inches.Door Hardware: Stainless steel Ball bearing Hinges 3 Nos, Minimum 90Kg hydraulic surface applied rack and pinion door closers, Mortice Sash Lock with cylinder. One Side Handle and Other Side with 2 point Panic Bar. 165 Road Work 166 Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30 167 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. 168 Water proofing 169 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 170 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) 171 Landscaping 172 Supplying of Flowering Shrubs (Heliconiya st. Vincent red, Ixora bush, Cana durf etc..) 173 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removalof unsaverieable material?s as per direction of officer in charge (including cast of plant & water )Cost of plantation per trees plants (for 100 nos.=427.45/100) 174 Providing and Laying Landscaping of outdoor area with buffalo grass and small plants with all necessary levelling and filling as required. 175 Signage 176 Providing and fixing in position the signage board made out of 3 mm opaque PVC foam board of computerised cut, PVC non reflective self adhesive vinyl painted foam board of required size and colour. 177 Providing and fixing non lit Signages made of CNC Cut Stainless Steel projected letters and fixing it at site with all necessary fitting arrangements and accessories as per the design and requirement on instructions of the engineer in charge. 178 Furniture 179 Two tiered reagent racks (MS with powder coating) with granite top of 150 mm depth for side workbenches. The two tier should be placed at a minimum spacing of 300 mm. The item should be in compliance with IS 4209 (2013), NABL etc. The Length should be customized as per lab workbench and vertical posts must be placed at appropriate spacing. 180 Supply and Installation of Sink Module with SinkEach sink module should have a minimum dimension of 900 mm (L) x 900 mm (W) x 900 mm (H) and made of MS as per IS 1730 shall be designed with a single cabinet (with 2 shutter, SS304 hinges for easy and noiseless opening and closing mechanism). This module should include a sink made of 5 mm thick polypropylene with black color body. Minimum Dimension of the sink: 450 mm (L) x 600 mm (W). Sink should include PVC tap connection-15mm diameter (Goose neck type), grating etc. The sink module shall be portable and provided with 18mm thick granite table top (with cut out for providing sink). Item to be inclusive of all necessary fitting arrangement.The item should be in compliance with IS 4209 (2013), NABL, WHO etc. 181 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 750 mm D 182 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 890mm D 183 Supply, Installation, Testing and Commissioning of Eye wash with Brass inject mould with epoxy powder coated body with auto released Valve and cup shaped water dispenser with min 1/2 HP power pressure booster pump 184 Counter Height Stools :Supply and erection of counter height stools ( bar stools ) of following specifications : Revolving adjustable Chrome plated steel body chairs with resistance to the corrosion. Cushion Seat with Lift mechanism for Adjustment of height. Minimum height 750mm before expansion. Medium Back rest and arm rest. Item shall be of reputed make. 185 Office Chair: Non-revolving executive chair with fixed armrest providing natural resting for arms. Seat with PU cutted foam backed fabric, back rest with mesh type fabric, Upholstery: Heavy duty rubber backed fabric in BLACK ( Size -55x60 cm) 186 Executive Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 187 Revolving Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 188 Cabinet/Wardrobe: Providing and fixing Cabinet/Wardrobe unit with 18 mm thick Multi wood board with one side decorative and other side balancing lamination. cupboard shutters edge to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickel plated bright finishing M.S. piano hinges conforming to IS:3818 marked with fixing chromium plated brass 50 mm cupboard or wardrobe knobs, special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. Depth of shelves to be 300-600mm and shelves to be fix with proper support and bracket holders. as per layout drawing approved by Engineer in charge. Make laminate: Greenlam/ Merino / Century. Only front elevation will be measured. 189 Supply and erection of Airport type 3 seater waiting chair with powder coated chromium finish having minimum dimensions 1675mm length X 710mm width X 775mm total height and 400mm seat height . Seat: High quality cold rolled 1.2mm thick steel perforated sheet pressed and welded to form the shape. Arm & Leg: High quality 1.2mm thick MS Tube / Sheet . Cross bar: High quality cold rolled 2mm thick steel sheet pressed and welded to form the shape. 190 Table of size Min 2300x600mm Made of minimum 18mm BWR ISI (303 Grade) plywood (Century, Greenply, Fineply or equivalent). On top and all sides with 1mm thick hot press (3M or Henkel) laminates (Brand MERINO, Associates or equivalent) of approved colour and pattern as per the design. The table is provided with 1 drawer, 1 Storage, 1 key board locks, handles, mini fix, dowels and screws. Exposed edges to be finished with 0.8 mm edge band as per specified colour. 191 Supply of wooden table with one drawer and Cupboard unit made of hard wood varnishing/painting all complete. Size: 1200x600x750mm 192 Providing & supply of Conference Table with executive chair of 13 Pax with the following specifications.Table top size :3600 x 1200mm. Table Tops –made of 25mm thick MDF with waterfall top edges finished in PVC Membrane using unique wrap around technology for better aesthetics & long lasting use. Under structure – Legs made of 25 mm thick standard Black matt colour post formed panels interconnected with 18mm thick standard Black matt colour pre-laminated modesty panels, with height adjustable levelers to take care of uneven floors. Wire Management & Concealed wire management to take care of basic wiring requirements both horizontally & vertically. For closed configurations, liftable top cover, made of 12mm MDF finished in PVC Membrane, is provided to access the horizontal wire carrier. Vertical wire management is through flexible vertical wire manager, popup grommet with power & RJ45 Socket. Designed for Flexibility through modular Construction, PVC Membrane Finish Tops for seamless surface, Post formed Legs for safe use, Provision for easy wire management, Upgradeable / reconfigurable for future needs. 13 Nos Revolving adjustable type Medium height Back Office Chair with arm rest with back tilt and swivel mechanism constructed out of mild steel and high quality plastic. 193 Supply of wooded Chairs with armrest of Hard Wood Plank Seat and Reaper Back. 194 Supply of Wooden Bench and Desk made up of Mahagani of minimum size - Bench Size :1 83x30X46cm Desk Size :183x41x75 cm 195 Supply and installation of steel podium made of SS304 with min dimensions 500mm X 450 mm X 1200mm and having a sloped top surface, and having a decorative/ plain front face all made of SS 304 as per the design and approvals of the architect/ Engineer - In - Charge 196 Wiring-General Electrical work 197 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 198 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 199 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire 200 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 201 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 202 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 6 Sq.mm + 1 x 6 sq.mm earth wire 203 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 204 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 205 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 16 sq. mm + 1 X 6 sq. mm earth wire 206 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 207 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 208 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 209 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm 210 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm 211 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm 212 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair 213 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 214 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 215 Fixtures 216 Supply and Fixing suitable size modular GI box with cover in front on and providing and fixing 1 no RJ 45 including connections as required. 217 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). 218 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 219 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet 220 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) 221 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet 222 Supply and Installation of surface/recess mounted LED 2x2 luminaire with CRCA housing suitable with fully diffused diffuser for general lighting. The luminaire should have CRI > 80 and CCT of both 6500K/5700K, Cool White Light. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3700 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 36 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro or equivalent 223 Supply, conveyance and Installation of compact, 2 feet,10-15W,LED tube light with high lumen giving soft glare free light including all required mounting accessories, frames complete. (Philips/WIPRO/Havells or equivalent) 224 Supply, Installation of surface mounted LED Tubelight. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 30 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 25k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make - Philips, Crompton, Wipro, Havells 225 Supply, Installation of surface/recess mounted LED Round/Square luminaire with CRCA housing suitable with fully diffused diffuser for general lighting in office areas. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 110 lumen/watt and Minimum system wattage of 10 -15 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro 226 Supply, conveyance and Installation of compact 10-15W LED Bulkhead Light giving soft glare free, Cool White light & complete with electronic driver including all required mounting accessories, frames, complete ( Make: Philips/WIPRO/Havells or equivalent) 227 Supply, Installation, Testing and Commissioning of 1400 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 228 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 229 Supplying, conveyance and Installation of 150-250 mm sweep,1350 rpm, 3 - 5 blade BLDC Exhaust Fan including frames and all mounting accessories complete.Recommended Make: Atomberg Efficio/Crompton Brisk Air 230 Supplying, conveyance and Installation of BLDC Type Wall Fan having 3 blade, 400 mm sweep, Speed 1350 rpm, Air Delivery 70 CMM minimum, Wall Mount Fan including frames and all mounting accessories complete. Recommended Make: Atomberg Renesa/V-Guard ENVIRO WF BLDC/Havells Platina 231 Supply, Installation, Testing and Commissioning of 450 mm sweep, 900 rpm heavy duty exhaust fan with louver in existing opening including making good the hole to suite the size of above fan complete with connections using 3 core 1.5sqmm multi core pvc sheathed copper conductor cable etc as required. 232 SITC of skirting light fitting with white LED 3 module along with suitable size modular metal box with inner and outer plates with all accessories. 233 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). 234 Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. lCD 235 Supply and installation of 2 Nos. 4 ft MS powder-coated hanging rods for tube lights, including supply and laying of 1.5 sqmm copper PVC insulated FRLS wire (3 runs: Phase, Neutral, Earth), necessary hardware (ceiling clamps, saddles, junction box, connectors), complete mounting, terminations, testing, and labour charges — complete in all respects. 236 Network and CCTV System 237 Supply of 16 ports Network Switch, Rack-mountable 10/100/1000 Mbps, Switching capacity 35.7 Mbps Features: Flow control, Layer 2 switching, auto-negotiation, auto- uplink (auto MDI/MDI-X), Weighted Round Robin (WRR) queuing, Quality of Service (QoS) Power: AC 120/230 V (50/60 Hz) complete. Make D-Link/TP Link/Cisco or equivalent 238 Supply Installation Testing and Commissioning of 32 channel embedded Linux NVR (Network Video Recorder), must connect 32 channel IP cameras, Should support min 2 SATA HDD and each should support Min 2TB and must record video simultaneously, (Recording Type: Continuous, Motion Detection, Alarm, Smart Event, Event Motion Detection, Alarm, Smart Event), Video Compression H.265(HEVC)/H.264+/H.264, 2 Year Warranty, Image quality should be maintained throughout the warranty period. Make: CP Plus/Hikivision/Dahua or equivalent 239 Network Switch for CCTV. 16 Port PoE Switch 1000BASE-T Copper Ethernet PoE+ connections, 10M/100M/1G RJ-45 copper ports, 1000BASE-X Fiber SFP ports, 16 port Auto sensing 10/100/1000 Mbps PoE, minimum CPU memory 512 MB with 2 SFP/combo ports, Energy Efficient Ethernet (IEEE 802.3az) Make: CP Plus/Netgear or equivalent 240 Supply, Conveyance and Installing of 2MP IP Dome/Bullet Camera having Progressive Scan True Day and Night Colour IR Camera having effective pixel of 2 MP, Video frame rate of 2MP @30FPS, Minimum illumination of 0.01 [email protected], 0 lux@IR On, 20 M IR Range, 24 IR LED, AWB, AGC, BLC, 2D Noise reduction, with 3.6mm board lense, 12 VDC, PoE IP67 rated weatherproof performance. 1 year warranty. Make: Bosch/CP Plus/Honeywell or equivalent 241 Supply and fixing of 6U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete 242 Supply Installation Testing & Commissioning of 16 Port Loaded Cat 6 - U/UTP Modular Toolless Patch Panel having a metal structure enabling them to be durably fixed to the uprights of the 19 chassis. Include rear cable manager to hold cables without need for cable ties. The termination of I/0s shall be without any manual crimping tools. 243 Supply and fixing of 4U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete. 244 Supply and connecting 2 meter long CAT6 cable Patch cord having RJ45 connectors crimped at both ends, to the existing outlets as required. Make: D-Link/TP-Link or equivalent 245 Supply and Installation of LED Color display of minimum 32 inch screen, complete, UHD display Make: LG/Samsung/Panasonic or equivalent. 246 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable 247 Supply, Installation and Integration of Dual Band WiFi Access Point on false ceiling along with accessories, having Fast Wireless Speed, simultaneous 2.4GHz 300Mbps and 5GHz, 867Mbps Dual Band connections for 1.2Gbps of total available bandwidth, Superior Coverage of Four Fixed External antennas provide stable wireless connections and optimal coverage, App Control, Interface of 1× 10/100 Mbps WAN Port and 4× 10/100 Mbps LAN Ports having Working Modes (Router Mode / Access Point Mode). Make: TP-Link/Netgear/DLink or equivalent 248 UPS 249 Supply, Installation, Testing and Commissioning of True on-line Double Conversion 10 KVA UPS system with 3:3 Crest Factor Three Phase Input Three Phase Output. Inversion shall be Microprocessor controlled with instantaneous sine wave Control using IGBT. UPS shall have standard display features, alarms, safeties, etc Input Voltage range : a) Phase – Three Phase with ground b)Voltage range 190 VAC – 470 VAC c)Input Frequency :50/60 Hz d)Power Factor : 0.95 or above e)THD : less than 5% with full load Bypass f) Voltage Range – 200VAC – 240 VAC ) Frequency range – 45-55 Hz/55-65 Hz Output Voltage Range h)Voltage Range – 200VAC – 240 VAC i)Frequency range – 50/60 Hz j)Voltage distortion – linear load <= 2% k)Voltage distortion – nonlinear load <= 5% l)Output waveform – pure sinewave m) Crest Factor – 3:1 Minimum Back up time : Continuous 30 Minutes at full load Rectifier shall be Full wave Type (Shall fully meet the specified input power requirements) Battery Type: Sealed Lead Acid Maintenance Free DC Voltage : 96V DC System, Battery Nos and capacity shall be designed for optimum storage space. Installation &Commissioning Required Breakers also needs to be provided in input and output side for the UPS. Make: Liebert Vertiv/APC by Schneider/Numeric by Legrand 250 Cable Trays 251 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.375 mm width X 50 mm depth X 2.0 mm thickness 252 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness 253 Fan Clamp 254 Providing and fixing 16 mm S.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 255 DB and Switchgear 256 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) 257 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 258 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 259 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door 260 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 261 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural 262 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole 263 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 264 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 265 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps 266 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 267 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 268 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts C curve TP MCB complete with connections, testing and commissioning etc. as required. 269 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 270 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral 271 Earthing and Lightning Arrestor 272 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re- filling etc. as required. 273 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 274 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. 275 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 276 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 277 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 278 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 279 Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. 280 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube,having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 281 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 282 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 283 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 284 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG) 285 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) 286 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG) 287 Street Lights 288 Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 289 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps 290 Water Purifier 291 Supply and Installation of Water Purifier having Multi-Stage Filtration: RO (Reverse Osmosis), UV (Ultraviolet), UF (Ultrafiltration), Storage Capacity: 7-9 Liters, Purification Features: RO: Removes dissolved impurities, heavy metals, and salts.UV: Kills bacteria, viruses, and other microorganisms. UF: Filters out fine particles and microorganisms. Mineral Booster: Adds essential minerals to enhance water taste.TDS Controller: Adjusts Total Dissolved Solids for taste preference. ActiveCopper: Infuses copper ions into the water for added health benefits.Aqua Taste Booster: Enhances the taste and maintains optimum pH level. In-Tank UV Disinfection: Keeps stored water pure.Smart Display/Indicators: Alerts for filter change, UV fail, water level, and service needs. Super Fine Sediment Filter: Removes fine and coarse particulate impurities. Water Level Indicator: Monitors the purified water level in the storage tank. Make: Aquaguard Aura 7L/ Bluestar Aristo 7L/Kent Grand Plus ZWW 9-Litre/ LG 8L 292 LT Cabling and Termination 293 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 294 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 295 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp 296 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 297 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp 298 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm 299 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm) 300 Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 400 sq mm 301 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm) 302 LT Panels 303 Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work. General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall befl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 400A 3kA 4 Pole MCCB - 1no Ics = 100% Icu rating Digital Voltmeter 0- 500V with selector switch & Digital ammeter (0-400A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 400A. Out going : 250A ,50kA 4 Pole MCCB - 2no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 304 Lift panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 40A ,16-25kA TP MCB - 6 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list.Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 305 Sub Panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required. Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch &Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 32A ,16-25kA 4 Pole MCCB - 4 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 306 SSB2- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 250A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-250A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 250A. Out going : 1) 63A ,16-25kA 4 Pole MCCB - 8 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 307 Transformer 308 Supply , Installation, Testing and commissioning of 500 kVA outdoor unitized substation with an 11kV/433V dry-type cast resin transformer and a 630A VCB typically includes a compact prefabricated design conforming to IEC62271-202 standards, offering IP53/IP23 protection, and featuring compartmentalized construction to prevent accidental entry into energized areas. The substation is designed to withstand electrical impulses, thermal, and dynamic stresses, ensuring reliable and robust performance with low power loss and noise levels. The installation involves placing the substation on a prepared concrete plinth, connecting high-tension (HT) and low-tension (LT) cables, and ensuring proper earthing and safety measures. The commissioning process includes testing the transformer, switchgear, and protection systems to verify operational integrity. Make: Unipower/Intrans/Voltamp 309 MSB and APFC Panel 310 Supplying, installation, testing & commissioning of cubical type MAIN SWITCH BOARD suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having front surface area 6 sq.mtr (Approx.) fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 630 Amp capacity extensible type TPN aluminium alloy bus bars of height conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :- Interlocking:Electrical through advance contacts in MCCB/ ACB’s (incomers & bus couplers) and mechanical (castel key) interlocking should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possibility of accidentally approaching two supplies at one bus section.Interlocking b(I) Incoming : 2 Nos 800 Amps (DG and MAINS) each four pole ACB of fault breaking capacity 50 KA (Ics=Icu upto 433 V manually operated, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS 1397- 2 : 1993 as amended up-to-date complete with following accessories for each MCCB(a) Independent manual spring closing mechanism- 1 No.(b) Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection- 1 set.(c) Digital* type Voltmeter (0-500 V), with selector switch & back up HRC fuses/MCBs-1 set. (d) Digital* type Ammeter (0-.600 Amp), with selector switch and one set of 3 nos. CT’s of ratio. 800/5A Class I accuracy and 15 VA burden- 1set. (Ratio to be fi lled up).(e) 3 Nos. Phase indication LED lamps with 2 Amp back up HRC fuse, breaker ‘ON’ indicating light with 2 A HRC fuse, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.(f) Shunt trip coil 220 V A.C. (II) Bus Bars :TPN aluminium bus bars of minimum of 800 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec (II) Outgoing :(1) (a) 4 Nos. 250 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 250/5 Amps Nos. (c) Digital* type ammeter (0- 400 Ap) with selector switch set. (2) (a) 1 Nos. 200 Amp4 Pole MCCB for (Ics = 35 kA upto 433 V) (b) CT’s of ratio 200/5 Amps set (c) Digital* type ammeter (0- 250 Amp) with selector switch set. (3) 3 Nos 160 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 160/5 Amps set (c) Digital* type ammeter (0- 200 Amp) with selector switch set. The switchgears/measuring instruments shall be as per the Choice of the Engineer in charge. The panel shall be mounted on required structural steel supports and frames for mounting, the price quoted shall be inclusive of the same. The panel shall have suitable provision for connecting to the incoming cables of 3R x 400 sqmm XLPE Aluminium cables and shall be provided with necessary earth leakage relays as per the Inspectorate Norms. The panel shall be as per the IS standards and shall conform to all norms of EB/Inspectorate/CEA. Make of Switchgear : ABB/L & T/Schneider Electric/Siemens/Legrand 311 Design, Manufacture, Supply, Installation, Testing and Commissioning of Automatic Power correction Panel having Incomer: 250A, TPN MCCB, Digital Multifunction meter for V,A,F,PF With CTs CL:1 with RYB Indication lamps-1 Set 250A Aluminium bus bar with heat shrinkable insulation sleeves-1 set, Intelligent power factor controller with control MCBs etc. complete The panel shall comprise of suitable combination of capacitor banks upto a total of 100 kVAR and shall be designed as per the standards of Electrical Inspectorate/CEA. 312 DG and AMF Panel 313 Supply, Installing, Testing and Commissioning of & Silent Type& Diesel Generating set having CPCB IV+ acoustic enclosure having Prime Power Rating of 500 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor and consisting of the followings: Diesel engine radiator cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories. Engine mounted Instrument Panel fitted with and having digital display and necessary indication coupled to Synchronous alternator rated at 500 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor. Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. Daily service fuel tank of 440-460 litres capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. Dry exhaust manifold with hospital exhaust silencer and catalytic convertor. 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (lead acid type) as required as per specifications. Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications. 314 Design, Fabricating, Supply, Installing, Testing & Commissioning of automatic mains failure control including auto by-pass panel, suitable for 500 KVA silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH & provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required, all complete and inter locking including the following: (a) 1 Nos. 630 Amp., 50 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50-100% having adjustable OL & SC. Set at 350A (b) Auto/Manual/Test/Off selector switch (c) 2 Nos. over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay. (d) 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering(e) Energy analyser unit to indicate current voltage frequency power factor and KWH(f) Indicating lamps for load on mains and load on set(g) Fuse for instruments(h) Battery charger, complete with transformer/ rectifi er, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.(i) Main supply failure monitor(j) Supply failure timer(k) Restoration timer(l) Control unit with three impulse automatic engine start/stop and failure to start lockout.(m) Impulse counter with locking and reset facility.(n) ON/OFF/Control circuit switch with indicator(o) Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning. AMF Panel shall be connected to Main Switch Board incomer with necessary interlocking arrangement to prevent simultaneous switching on of power supplies. All integration between Main Switchboard and AMF Panel is under contractor scope. 315 HT Cable 316 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium powercable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 300 sq mm 317 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm 318 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm 319 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm 320 Air Conditioning Works 321 Supply, Installation, testing and commissioning of 3 x 3 Cassette type Air Conditioner of following capacity and specifications: Consisting of ceiling-mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of energy-efficient suitable rotary compressor for operation on single-phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation, with R-32/R-410A or equivalent refrigerant and fixing of room (fan coil) unit on ceiling, standard 5 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1 dia drain PVC pipe with insulation up to 5 m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. (Make: Voltas, Blue Star, Daikin, Hitachi, Carrier or equivalent). Minimum 2 TR 3 Star rated (inverter type AC) as per BEE 322 Supplying additional copper piping of required size and connecting the same to the available piping and extension of the same through 100mm PVC duct inside false ceiling. 323 Electrical Dismantling Works 324 Dismantling of existing outdoor transformer and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 325 Dismantling of existing DG set 100 kVA, AMF panel etc and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 326 Electrical Works- Fire 327 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm 328 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 329 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 330 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 331 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) 332 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) 333 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm) 334 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 335 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 336 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 337 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 338 First Aid Hose reel &Wet Riser system 339 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.a.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585b.20 mm nominal internal dia gun metal globe valve & nozzle. c.Drum and brackets for fixing the equipmets on wall.d.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m 340 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 341 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way-100 mm dia M.S. Pipe 342 Supply and fixing of Air release valve SS body of 25 mm dia (UL Listed). 343 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 344 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 345 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) 346 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304) 347 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel 348 Hose Box - Supply, Installation, Testing and Commissioning of Hose Box -Double door - (cabinet) to accommodate Two pieces of 63 mm dia fire hose along with one pair of 63 mm dia male & female couplings and one branch pipe. The cabinet is made of MS sheet, painted in approved red colour with glass fronted hinged doors and lock &key (UL Listed). 349 Supply and Installation of Fire Brigade Draw-out Collecting head of CI Body having gunmetal 63mm dia instantaneous male draw out confirming to IS:903 suitable to fit on 100mm dia pipe with necessary flanges, rubber gasket, nut & bolts and other items. 350 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 351 Fire extinguishers 352 Supply &installation of ISI ABC type fire extinguisher of 4 kgs. Make SAFEX/ MINIMAX / CEASEFIRE or equivalent(UL Listed) 353 Supply &installation of CO2 type fire extinguisher of 4.5 kgs. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 354 Supply & installation of water mist type fire extinguisher of 9 liters. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 355 Supplying & Installing of Clean agent based automatic modular fire extinguisher (ceiling mounted) suitable for A,B,C class fires & electrical fires, Capacity- 5Kg 356 Supplying & Installing of Mechanical Foam (Stored Pressure) Type fire extinguisher of 9L capacity with mounting clamp. ISI approved. Make : SAFEX/MINIMAX/CEASEFIRE or equivalent 357 Fire Pumps & Fire Panel 358 Electric driven Main Fire Pump: Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.1620 lpm at 56 m Head 359 Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads. 1620 lpm at 56 m Head 360 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)a.Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325.c. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. As required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 56 m Head 361 Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector switch & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING (Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.Jockey Pump63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROLControl for diesel engine comprising - Automatic/Manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller.Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification 362 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 150mm 363 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 80mm 364 Supply and Installation of 12V DC, 200Ah maintenace free battery suitable for Diesel Engine driven fire pump operation with required connect cable set, battery stand. 365 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 100mm 366 Signages 367 Supply and fixing in position Exit Signages photo luminescent type with indication arrows and letters Exit/Fire Exit/ Staircase/FIRE/Fire Station/Fire Fighting Equipment/Fire Duct/ Fire Extinguisher/ Floor/Fire Command Centre/Fire Pump Room/ No Smoking / Danger/ Call point / Sounder Identification Numbers (Ground/ 1st/2nd)/ In case of the fire do not use lift, use stairs and other mandatory signages recommended by Fire Departments having dimension 30 cm x 15 cm complete inculding fixing mechanism. 368 Supplying and Installing in position the signages approved by Kerala state fire service - of minimum size 1ft x 1.5ft made out of PVC rigid sheet 3mm thick with computer cut PVC non- reflective self adhesive imported vinyl painted on the front of PVC rigid sheet complete with wall mounting arrangements with mirror screws. with lettering- ASSEMBLY AREA 369 Signboards: Supply and Installation of Fire Escape Plan with fire fighting equipment location, exit in A3 Foam sheet with plastic lamination with necessory accessories to fix it on wall. 370 Supply and fixing in position & Fire Order& signage in suitable size made of high quality PVC foam sheet with photo luminescent lamination to make it glow automatically in the dark, with suitable arrangement to fix it on wall. 371 Supplying & fixing in position Assembly Point sigange in suitable size on aluminium composite panel with suitable stand to fix it on open area outside building. Assembly Point 372 Terrace pump 373 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)a.Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325.c. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head 374 Design, Supply, Installation, Testing, and Commissioning of an Automatic Terrace Fire Pump Panel, including:- IP54-rated enclosure with powder-coated CRCA sheet steel.- 32A 16kA MCCB, 15 HP-rated pump 3P contactor, overload relay, and pressure switch for automatic pump operation.- Auto/Manual selector switch, START/STOP push buttons, hooter, timer, and protection features (dry-run, phase failure, etc.).- Indicators (Power ON, Pump Running, Fault, Low Pressure), meters (Voltmeter, Ammeter with selector switches).- Copper wiring, termination, and provision for cable glands.- Installation, onsite calibration, and full functional testing for pressure-based automation. 375 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 376 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 377 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 378 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 379 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100mm dia 380 Pressure Guage-Supply, Installation, Testing and Commissioning of pressure guage, 4 & dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 381 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations (UL Listed).20 mm dia Make : Kartar/ Atom 382 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 383 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 384 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 385 Above Ground Piping 386 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia 387 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia 388 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia 389 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :250 mm dia (wall thickness 6.3 mm) 390 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150 mm dia 391 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :200 mm dia (wall thickness 6.3 mm) 392 Supply and Installation of 80mm dia M.S. &C& Class Diesel Engine exhaust pipe duly insulated with 50mm thick Glass wool with 1mm thick aluminium sheet cladding with bellows, flexible joint, necessary support, making hole in brick wall for pipe installation.Pipe dia 80mm 393 Underground piping 394 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 150 mm. Make - TATA / JINDAL 395 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 200 mm. Make - TATA / JINDAL 396 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (1m below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 100 mm. Make - TATA / JINDAL 397 Valves, measuring devices & switches 398 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required:200mm dia 399 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required80 mm dia 400 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 401 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required150 mm dia 402 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80mm dia 403 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150mm dia 404 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.150mm dia 405 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. 406 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 407 Pressure Gauge-Supply, Installation, Testing and Commissioning of pressure gauge, 4 dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 408 Supply and fixing of Air release valve Brass body of 25 mm dia (UL Listed) following IS standards, with required pressure rated. 409 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 410 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 411 MOEFA system, Automatic Detection & Fire Alarm System 412 Supplying, installing, testing and commissioning approved make Microprocessor based Multi-loop, Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 trouble events including1000 alarm log history events, Self Programmable alphanumeric keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 Loops. Each loop shall have a capacity of minimum 125 detectors & 125 other devices exculding 20% spare. The panel shall work in degrade mode in case of CPU failure, Products not having this feature may offer Redundant CPU. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition with the charging capacity of 200AH. The panel shall be capable of self programing without any dependancy on dongle or programming software. Quoted rate shall include supply of necessary software & hardware for progamming the panel with all necessary licence. Panel shall have Modbus over IP protocol for future integration with BMS. However, for present arrangement FA system will be standalone with 24x7 monitoring. The panel shall be capable of connecting to the cloud platform/solution. Complied to meet UL864, 10th Edition 6 Loop Networkable Addressable Fire Alarm Control Panel(Make: Honeywell or Equivalent) 413 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 414 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 415 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 416 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. 417 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 418 Supplying, Installation, testing & commissioning of external power supply unit provides regulated and filtered 24 VDC power for hooter operation.Battery backup with built in charging. 419 CABLING & WIRING Supplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 420 Miscellaneous 421 Preparation of initial and final drawings, submission to Panchayath, Municipality, KSEB, Electrical Inspectorate, Kerala Water Authority, State Pollution Control board, Fire Department, Factories and Boilers and other agencies if any for getting approval, sanction and No Objection Certificate for building permit and completion from Fire Department and other department. Quoted rate shall be excluding statutory fee (All statutory fees shall be borne by Client-actual statutory fees shall be reimbursed on submission of original bill/challans from authorities).
Contract Date: Jul 17, 2025 Contract Value : 11.48 Crore
Boards / Undertakings / PSU No of Bidders 1
13.
Public Administrative Department #10363312 Price Bid
Tender For Construction Of New Office Building Of Municipal Board Nawa - CIVIL WORKSClearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 2 Earth work in excavation by mechanical means (Hydraulic Excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils 3 Add extra for foundation/trenches/drains for every additional lift of 1.5 Mtr. or part thereof inAll kinds of soil 4 Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. 5 Supplying chemical emulsionin sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20% 6 Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion) . 7 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). (UNDER FLOOR) 8 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). (FLOOR UNDER FOOTING AND FOUNDATIONS 9 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M25 grade Design Mix by usingmin 410 kg of cement per Cum . 10 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M25 grade Design Mix by usingmin 410 kg of cement per Cum . 11 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix 12 Providing and laying in position Ready mix concrete manufactured in fullyautomatic Batching Plant andtransported to site intransit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge.All works upto floor V floor. Design Mix by usingM-25 grade concrete by using min 410 kg of cement per Cum 13 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 14 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : Walls (any thickness) including attached pilasters,buttressesplinthandstring course. 15 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 16 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Columns, pillars, posts and struts etc. 17 Add extra for additional height in centring, shutteringwhere ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at alllevels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan are is to be measured) 18 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.(Original producers who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Thermo-mechanically Treated bars (Conforming of relevent IS code) 19 Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Grade 304 20 Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m) fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.Hot finished welded type tubes. 21 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). 22 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) 23 Half Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 75 in superstructure above plinth level upto floor V level in. Cement mortar 1 : 6 (1 cement : 6 coarse sand) 24 Add extra providingand placing in position 2 Nos. ,6mm Ø M.S. barat every thirdcourse of half brick masonry 25 Providing and fixing Stone jali 40mm thick Red/Pink sand stone throughoutin cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali patterns to be cut square to jali slab without any chamfers etc: 26 Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 20mm thick . 27 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) 28 Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth completeNew Plastered Surface (three or more coats) 29 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect 30 Finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specificationsincluding primer coat and protecting coat including scaffolding and safety provisionTrowel Finish av. thickness 1500 to 2000 microns. 31 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade :Two or more coats on new work 32 Making of drip course (Tapka) in cement sand mortar 1:6 width upto 40 mmand 10 mm thick as per approved design 33 Making grooves as per design in plaster 10mm to 20mm wide. 34 P & F 1st quality Heavy Duty Vitrified Double Charged tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete.Size 600X600mm 35 size600 mm X 1200mm 36 P & F 1st quality Heavy Duty Vitrified glazed MAT tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. size600 mm X 600 mm 37 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 38 Extraforusingsize above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finishedtiles in place of 300mm x 300mm size. 39 Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm 40 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete For area of each slab upto 2001Sqcm 41 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. 42 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) Medium shade using approximately 50% white cement and 50% ordinary cement. 43 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.South Red1501 Cm2 to 3600 Cm2 Tiles 44 Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite/Kota Stone Work Full Edge moulding 45 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete 46 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete 47 Providing and fixing 1st quality standard Marble printed/ Granite Shade or Light/dark shad glazed tiles confirming to IS : 13753 & IS :15622 of size 300mm x 600mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 48 Providing and fixing wall panelling using soft wood frame of size 50x25mm @600 mm c/c in both directions duly treated with anti-termite treatment making grooves painting of grooves specification and drawing using : ISI 9 mm teak ply one side BWR 49 Providing and fixing pressed steel door frames confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applyinga coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4(M15 grade) complete as directed by Engineer-in-charge : Profile E 50 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A: 35 mm thick . Commercial Veneer both side 51 Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. 52 Providing & Fixing mica of approved make for inner/outer side of shutters with fevicol & nails completeas per approved by engineer in charge. 0.8mm thick mica 53 Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint 54 Providing and fixing fully panelled /partly panelleddouble leaf shutters frame for windows and ventilators as per approved design and drawings with approved steel fittings as per Annexure ‘A’ and width of styles, bottom and top rails 75mm including intermediate rails 50mm wide, beading of 25mm x 15mm size on both faces : 35 mm thickGhana wood grade I 55 Providing and fixing bright finished Mortice lock of approved make Godrej or equivalent withpair ofCP handles for doors with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge. 56 Providing and fixing of uPVC casement fixed windows or ventilators manufactured in ISO 9001:2000 & 14001:2004 certified company. Frame : Made from the Extruded uPVC Window Profile Section of size 60 x 60mm having outer wall thickness of 2.25mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2mm thick G/J/U/O TYPE GI section. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of acCumulated water, if any, to outer side. Fix Mullion made of 76 x 60mm uPVC Profile Section with steel reinforcement shall be provided in windows as per the requirement. Frame shall have ‘O’ type EPDM gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Glazing bead of size 34 x 20mm with ‘K’ & ‘O’ type inner and outer EPDM weather seal gaskets alongwith 5mm thick ISI make plain float glass.All welding joints of frame and shutter shall be cleaned and milled with the CNC mechanism to provide uniform grooved finish on all visible joints. Hardware : Installation at Site : Complete window is to be installed on site with 10 x 100mm fastners with white cap in existing pre-finished wall cut-out cemented to glass level plane at all height & width and silicon glue is applied to fill up the crevices between wall and window frame. Complete in all respect as per the drawing and specifications and direction of engineer-in-charge. (Insert 6mm tougend glass) 57 Providing and fixing of uPVC Sliding windows: Frame Made from the Extruded uPVC Window Profile Section of size 106w x 50h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2 mm thick GI section. Frame shall have three track configuration, two for sliding of window shutter and one for mosquito mesh shutter. Vertical member of frame which bears the sliding shutter load shall have aluminium rail/track for smooth sliding of shutter rollers. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side.Shutter : The shutter of sliding window shall be made of 39w x 69h mm Extruded 3 box multi- chamber uPVC Window Profile Section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5mm thick GI section duly mitered cut & thermal welded at all corners and fitted with uPVC glazing bead of size 22 x 20 mm with inner and outer co-extruded EPDM/TPE-Eweather seal gaskets alongwith 6mm thick ISI make plain float glass. Mesh shuttershall be made of 39w x 69h mm Extruded 3 box multi-chamberUPVC Window profile section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5 mm thick GI section duly mitered cut & thermal welded at all corners and fitted with nylon/polymer mesh and rollers/pully. (Insert 6mm tougend glass) 58 Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately). For fixed portionPowder coating aluminum( minimum thickness of powder coating 50 micron) 59 Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.)With float glass panes of 8 mm thickness 60 Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge.Pre-laminatedparticleboardwithdecorativelaminationononesideandbalancinglaminationonotherside. 61 Grading roof for water proofing treatment withwater proffing compoundCement mortar 1:3 (1 cement : 3 coarse sand) 62 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 63 Making khurras 450 x 450mm with average minimum thickness 50mm cement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1 : 3 and one coat of neat cement, rounding edges and making and finishing the out let complete. 64 Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg ofVG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. 65 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40mm wide and 4mm thick 66 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proffing cement compound @0.253 kg//sqm .This layer will be allowed to air cure for 4 hours. b) Second layer of slurryof cement @ 0.242 kg/sqm mixed with water proffing cement compound @ 0.126 kg/sqm This layer will be allowed to air cure for4 hours followed by water curing for 48 hours. The rates includes preparation of surface treatment & sealing of all joints ,corners,junction with polymer mixed slurry. 67 Providing&fixingprecastcementconcretecoping1:2:4mix50mmthickcompleteas per specification : 68 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-voilet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall confoim to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 5.0mm thick (Wt. 8.4 Kg./Mtr. Sq.) 69 Providing & fixing 12 mm thick tegular edge Glass Fibre Reinforced Gypsum False ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/Sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per 70 Providing and fixing 12.5 mm thick tapered edge gypsum board conforming to IS 2095- Part I at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting. 71 P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor 72 P & F water closet Seat Covers with brass hinges complete :Solid PVC (ISI marked) grade-I White for EWC. 73 P & F White Vitreous China Double Syphonic European W.C. (I.S:2556Mark) with mounted W.V.C. flushing cistern of (IS : 2556 Mark) of 10 litre capacity complete with all necessary internal fittings including cutting and making good the wall and floor. 74 P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: (Size 580x440 mm.) 75 P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall: :PVC with PVCbend as per IS : 7231 . 76 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : Size 630 mm x 500 mm dia for counter top 77 P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers. Size 600 x 450mm x 4 mm thick 78 Stainless Steel Sheet size 125mm dia. Heavy Quality of approved make 79 P & F Liquid Soap Container with brackets complete of approved make: C.P. brass 80 P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. 81 P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls and floors:15 mm dia nominal boreB Class 82 25 mm dia nominal boreB Class 83 P & F G.I. Pipes (External Work) with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc.15 mm dia nominal boreA Class 84 25 mm dia nominal boreA Class 85 50 mm dia nominal boreA Class 86 Concealed pipe in wall including painting with anticorrosive bitumen paint 15 mm dia nominal boreB Class 87 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: C.P. Brass bib cock,15mm nominal bore. 88 P & F Stop Cock(IS :8931 Mark),superior quality & ofapproved make: Brass 400 gm. 15mm nominal bore. 89 P & F Ball Cock (IS :1703 Mark) with Rod& P.V.C. Ball complete : Brass wt.Not less than 400 gm, 20mm. 90 P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc.C.P. Inlet connection 15mm.Brass (IS : 8931 marked) 91 P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :Gun-metal 15mm nominal bore. 92 Gun-metal 25mm nominal bore. 93 Gun-metal 50mm nominal bore. 94 P & F Gun-metal Non-return Valve or Check Valve (IS :Make) of approved make, superior quality:50mm nominal bore. Horizontal 95 P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved desig1000 Lt. Capacity 96 500Lt Capacity 97 Hoisting Charges for each floor :For ITEMS 2.26.1 TO 2.26.4 98 For ITEMS 2.26.5 TO 2.26.8 99 P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant110mm dia 100 160mm dia 101 P&FrigidPVCpipefittings(IS:4985mark)ofapprovedquality/makeincludingjoining the pipe with solvent cement rubber ring and lubricantCoupler (socket)75mm dia 102 110mm dia 103 160 mm dia 104 Reducer 110 X 75 mm110mm dia 105 160 mm dia 106 Plain Tee75mm dia 107 110mm dia 108 160 mm dia 109 Door Y110mm dia 110 160 mm dia 111 Bend 45110mm dia 112 160 mm dia 113 Bend 87 .5110mm dia 114 160 mm dia 115 Door Bend (Top Side110mm dia 116 Vent Cowel110mm dia 117 P- Trap110mm dia 118 Gully trap110mm dia 119 Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.Depth up to 0.5 M 120 Construction of Man hole, in all types of soil, inner size 1.5 x 1.2 M, with 450mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50 mm thick M-15 grade C.C. flooring making channels, 80 mm thick stone slab covering with 40 mm thick M-15 grade C.C.flooring, Ferro Cement cover with frame of 450mm dia, earthwork etc. complete including disposal of surplus earth within 50 mtr. lead as per design :Depth up to 1.5 M 121 Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. Inside size 450 x 450mm depth upto0.5 M Cement cover with frame 122 Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C flooring & over stone slab covering ,80 mm thick slab ,jointing of slab in CM 1:3. Ralthal, Kharanja,50 mm thick stone partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos C.I foot rests of approved design ,two No. 450 mm dia each Ferro cementcover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:- Size 400 x140x150 cm.(for 50 users) 123 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make75 mm dia 124 110 mm dia 125 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /makeCoupler75mm dia 126 110mm dia 127 Bend 87.5 Dg.75mm dia 128 110mm dia 129 Bend 45 Dg.75mm dia 130 110mm dia 131 Door Bend 87.5 Dg.75mm dia 132 110mm dia 133 Single Y75mm dia 134 110mm dia 135 Socket Plug75mm dia 136 110mm dia 137 Pipe Clip75mm dia 138 110mm dia 139 Nahani trap with jali 4110mm dia 140 Vent Cowel 110mm dia 141 P & F W.V.C. (IS: 2556 Mark) Squatting Urinal of standard make complete. Including cutting & making good the floor:Size 450x350mm 142 P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete.Flat Back (small) size 456x355x265mm. 143 Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.:Size 240 Cm. dia outside & 240 Cm. depth 144 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 145 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 Sqm on plan) including disposal ofexcavated earth, lead upto 50m andlift upto 1.5 m , disposed earth to be levelled and neatly dressed : All kinds of soil 146 Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. 147 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. :M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 40mm nominal size). 148 Providing laying, spreading and compacting specified graded crushed stone in sub-base course including premixing the material at OMC in wet mix plant, carriage of mixed material, laying in uniform layers with motor grader, F.E.loader on a prepared surface and compacting with vibratory compactorto achieve the desired density including all material, labour, mach-nery, lighting barricading and maintenance of diversion complete.[MoRTH specification Clause 401] includiong with all lead 149 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand ) including making joints with without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete including painting etc. as per direction of Engineer-incharge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineerin- charge). 150 M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 0.5 to 2.0 MSA for a design life of 20 years.) like city streets, small and medium market roads, low volume roads, utility cuts on arterial roads, etc Category A Denated units to key into each other on four faces zigzagshape as per IRC SP 63:2004 151 Construction oftubewell up to 100m depth and above to accomodate housing and assembly pipe in all types of alluvium strata by rotay drilling method with code of practice for construction and testing of tubewells (IS:2800 (Part-II) : 1991 and IS:2800 (Part-II) :1979 both amended up to date) with supply of bail plug if necessary.The work will not include cost of housing pipe and strainer pipe assembly cost, gravel and development work. Work would be deemedcompleted only after obtaining sound free water during pumping.200 mm nominal bore 152 Diameter 900 mm+C159Construction of Recharge Shaft in filter pit including Earth work Excavation , lifting excavted earth with all lift and 50 m lead and centering & shuttering evenever required. 153 Supply & fixing Pre-cast RCC Rinngs at the mouth of recharge shaft of M20 mix with40 mm thicknessDiameter 900 mm 154 Supply & lowering air line of 25mm dia, G.I. pipe B class having perforation 3 to 5mm size all arrow of G.I. pipe in Zig-Zag fashion & making air vent at top including the cost of Tee-Nipples, Elbow, Socket etc. 155 Supply and lowering vent air pipe 63mm dia rigid PVC pipe(IS 4985) mark class II (4kg per cm2 ) with required all necessary fittings including perforation of 3 to 5 mm size all around the pipe at a distance of 180 to 220mm in zig zag fashion and making air vent at top complete as per direction of Engineer incharge. 156 Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids Size 9 to 12 mm 157 Size 3 to 5 mm 158 Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids. 159 Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985. 200 mm Nominal Bore. 160 Supply and Fixing of Big steel Almirah overall size of916mm (W )x486mm (D )x1980 mm(H) with weldedconstruction. It should have the shelf thickness of 0.7mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high y eld strength) and all other components shall have a thickness of 0.9mm. The Almirah should have a Mazak handle and Three way locking mechanism with Shooting Bolts.It should have a height wise adjustable shelf mounting .Itshould also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated. Plenty of colour options and shelving options shall be available ISimarka brand (Godrej or equivalent) as per approved colour, shape,design,type by engineer in charge. 161 Supply and Fixing of small steelAlmirah overall size of 760mm (W )x455mm (D )x1325 mm(H)with welded construction. It should have the shelf thickness of 0.7 mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high yield strength) and all other components shall have a thickness of 0.9mm. The Almirah should have a 2 Mazak handle and Three way locking mechanism with Shooting Bolts.It should have a height wise adjustable shelf mounting.It should also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated.Plenty of colour options and shelving options shall be available ISimarka brand (Godrej or equivalent) as per approved colour, shape, 162 Providing and supplying Canning Chair of size 455mm X 580mm X880mm. IIshould have wooden canning support at back and bottom supported by steel frame 3 2mm thick,powder coated round pipe with full armwooden handles onsides and other fittings as per direction of enaineer in charae. 163 Providing and supplying Canning Chair of size 455mm X 580mm X880mm. IIshould have wooden canning 4 support at back and bottom supported by steel frame2mm thick,powder coated round pipe without woodenhandles as per approved colour, shape,design,type by 164 Providing and supplying Officer high back Chair, The seat and back are made up of 1.2 cm thick hot pressed plywood, upholstered with fabric and moulded Polyurethane foam with PVC lipping all around.The back foam is designed with contoured lumbar support for extra comfort. BACK SIZE:65.0cm.(W) X 71.0cm.(H) SEAT SIZE:65.0cm. (W) X 65.0cm.(D) andreinforced with M.S. insert. The armrests are scratch and weather resistant. The armrests are fitted to the seat with seaUarmrest connecting strip assembly made of steel.The center pivot mechanism Is designed with the followingfeatures:360 revolving type.Tilt tension 5 adjustment. Upright locking.The pneumatic height adjustment has an adjustment stroke of 12.5 cm..The pedestal Is made of HR steel and fitted with 5 nos.twin wheel castors (castor wheeldia. 5.0cm.). The pedestal is covered with a P.P moulded cladding for modem and aesthetic looks.The pedestal is 65.0 cm. pitch-centre dla.(75.0 cm with castors). The twin wheelcastors are injection moulded In 30% Glass Filled black Nylon, as per approved colour, shape,design,type by engineer In charge. 165 Providing & Supplying table or size 1500mmx900mmx750mm, Top should be nnished with 18mm MDF Bos:d post formed Both side with 0.6mm laminate of approved make & design & with appropriate balancer on the bottom or the top. All verticals supportsincluding Modestypanel should be of 18mm prelaminated MDF Board with 2drawers & 16 Swing door per approved design.The drawers to beprovided with ai:proved handles and fixed on Telescope channels.AppropriateEdge Bendings to be provided where necessary with PVC beading 2mm thick to be provided. Footrest to be provided with 1Bmm MDF prelaminated board of the same color code.P&F PVC wire managers capslo be provided on the table top, as approved colour,shape, design,type by engineer In Charge 166 Providing & Supplying side table of size 900mmx450mmx750mm. Top should be finished with 18mm MDF Bos:d post formed with 0.6mmlaminate oras same as the Table,approved make & design & with appropriate balancer on the bottom or the topAllvert icals supportspanel should be of 1Bmm prelaminated MDF Board. Having 2Drawers & 1Swing7 door CPU unit. Keyboard tray, with mouse rest to beprovided.Appropriate Edge Bendings to be provided where necessary with PVC beading 2mm thick to be provided as per design.The drawers to be provided with approved handles and fixed on Telescope channels.P&F PVC wire managers caps to be provided on the table top, as per approved colour, shape,design, 167 Providing and $Upplylng table of size 1200mmX 750mmX750mm high as per design. The table top should be finished with 0.6mm thick laminated postrorming on 18mm thick MDF board.The 3 drawer unit (provided withlocking mechanlsm)and all other8 exposed vertical supports should be finished with steel members or approvedshade,colour and make.Appropriate moulding/edge bindingto be provided where necessary with PVC beading 2mm thick lo be provided as per approved colour, shape,design, 168 Providing & Supplying Computer table of size 900mmx450mmx750mm.Top should be finished with 18mm MDF Bos:d post formed with 0.6mmlaminate or as same as the Table,approved make & design & withappropriate balancer on the bottom or the topAllverticals supports panel should be of 1Smm 16.00 Each 12100.00 1g3500.oo prelaminated MDF Board. CPU uni Keyboard tray,with mouse restlo be provided.Appropriate EdgeBendlngs to be provided where necessary with PVC beading 2mm thck to be provided as per approved 169 Providing & Supplying depository/cashcabinet made up of CRCA steel with external size or 5g1 x 460 x 460 mm,2 nos of lockable drawers and single door cabinet fitted 3.00 Each 22848.00 68544.00with 6 leverlock system 1vith completein all respect. (approx weight 160 kg to 180 kg) as per approved 170 Book Case - 4 Door Book Case shall have the configuration or 914mm(W)x320mm(D)x1742mm(H). The unique design provides the right rigidity to the Top hinged doors ,which shall faci itate easy use.The Book Case shall be made fromprime quality steel. It shall have a Rigid Knock Down Conslructlon.The TopPannel, Back Pannel and Side Pannel are made from 0.7mm high yield CRCA andother components from O.Smm CRCA. Each door shall have a 6 Lever Cam Lock with Comrron Key. 3mm thick glass should beused in each door for clear inside vision whih shall besecured Ina metalframe through a rubber gasket.11 Scissor Mechanism should be providedin each door for 20.00 Each 17248.00 344960.00receding Inside the top or every compartment andItshall ensure parallel and smooth movement. Each door should be provided with plastic side end caps as handle which Is easy to grip.Each compartment shall have a storage shelf with good capacity. The 4 Door Book Case shall have 18mm PLB Top straight edge with PVC lipping.The Hn shlngshall Include Epoxy powder coated.Complete work as per the as per approved colour,shape,design,type by engineer in charge. 171 150 cm high fencing of precast R.C. posts of 15cmx15cm tapered to 10x10cm at top placed at every 3m apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth posts to be strutted with same R.C. posts provided with 6 horizontal lines and two diagonals of black barbed wire between the two posts fitted and fixed with G.I. staples including earth work in excavation etc. complete 172 FIRE FIGTHING WORKProviding, Fixing, Jointing, Testing & Commissioning of Heavy duty MS C class (Heavy) pipes conforming to IS 3589 / 1239 part-I for hydrant and sprinkler applicationsincluding cutting, screwing, welding etc. & forged steel fittings like elbows, tees, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts including cutting hole and chase in brick or RCC walls/ slab and making good the same. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of requiredshade complete as required. (Pipe to be tested @ 10Kgf/Sqcm for 2 Hrs.). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 mm dia 173 100mm dia 174 80mm dia 175 50mm dia 176 40mm dia 177 32mm dia 178 25mm dia 179 Supplying and fixing first -Aid Fire hose reel Drum wall mounted swinging type with MS construction powder painted in post office Red, conforming to IS 884-1985 with upto date amendments, complete with the following as required.(A) Thermoplastic / Rubber Hose(B)20 mmdia UL, FM Bronze / SS nozzle with 5mm orifice (C)Drum and brackets for fixing the equipments on wall.(D) Connections from riser with 20/25 mm dia Brass/GM gate valves with screwed end and conforming to IS:778 Class-1through Forged steel Screwed Union & M.S. pipe. Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . With 30 m x 20 mm High Pressure Braided Rubber Hose as per IS:5132 - 1969and Bursting pressure 42 Kg/sqcm 180 Supplying and fixing of SS 304 Single / Double headed oblique pattern hydrant landing valve (internal/external) with 75 / 100 mm dia flanged inlet & 63 mm dia instantaneous type female outlet coupling with cast iron wheel complete with ABS cap and chain and all accessories as per IS:5290-93 (Type-A) in cluding matching flange (14 mm thick),nuts, bolts, washers, gaskets,etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Single Headed with 75 mm Dia. Flanged Inlet 181 Supplying and fixing of flexible hose made with 100% polyester, black EPDM internal rubber lining with External coat of synthetic elastomer (IS:636, type-A)63 mm dia, 15 mtr. Long RRL hose pipe with instanteneous type 63 mm dia SS-304male and female couplings(IS:903) duly bound and riveted to hose pipes with copper rivets and SS wire etc. as required.Appropriate Test Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. 182 Supplying & fixing SS-304 Short Branch Pipeconforming to IS: 903:93 fitted with 20mm (nominal internal diameter)bore nozzle, for projecting water in form of solid jet. The Branch shall have 63mm Male Instantaneous Inlet, suitable for use with 63 mm size Fire fighting hoses. H.P. tested to 21 kgf/cm² for 2.5 minutes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 183 Supplying and fixing of 750 mm x 600 mm x 250 mm Outdoor application Fire Hose Cabinet made of 1.6 mm thick MS sheetDuly powder coated in red color externally and white internally with 6 mm thick glazeddoors with Expanded Metal 2 mm thick Jali including necessary locking arrangement suitable to accommodate 2 Nos 15 Mtr. Long RRL Hose and 1 No. branch pipe on Existing Wall / Angle Iron Frame as required. (Cost of MS structure for mounting Frame is to be Paid Extra) All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 184 Providing and fixing of Fire / Electrical Shaft Door made frompowder coated (50 Micron) aluminiumpartialy glazed with 6 mm thick glass and Partialy/ Fully Louvered with Outer frame of AluminiumSection of Size 100 mm x 45 mm x 1.5 mmand Shutters Top, Middle & sideSection of Size 82 mm x 45 mm x 1.5 mm, Bottom Section of Size 110 mm x 45 mm x 1.5 mmComplete with Hinges, Tower bolt, Handle, Aldrop, Locking Arrangement including dash fasteners of required dia and size, necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. as per drawings and the directions of Engineer-in-charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 185 Supplying, Installation, Testing & Commissioning ofElectrical Driven fire fighting duty Terrace pump as per TAC andIS 12469-1988., Factory assembledin Pump make OEMsuitable for automatic operation and consisting of following details given asA, B, C, D, E, F, G and H.(A) Horizontal End suction Centrifugal Back pull type pump complete for delivery of below mentioned discharge and Head(B) Material of construction : Pump Casing - Cast Iron, Impellor- Bronze, Shaft - SS 410, Packing - Mechanical Seal(C) Squirrel cage induction motor (IE-3 Class) suitable for 3 phase, 415 V, 50 HZ, Ac supply , Class -F Insulation, Synchronous speed not Exceeding 3000 RPM, T.E.F.C confirming to IP:55 , of required HP suitable for the above pump ,along with flexible (Love Joy type) coupling , coupling guard complete in all respect .(D)Common bed plate fabricated frommild steel channel for installation of pump and Motor including anti vibration pads.(E) The Hydrostatic tests (2 times of design operating head or 1.5 times the shut off head whichever is higher) and performance tests (to determine developed head, Pump BHP and efficiency v/s Flow) of pumps along with trip test shall be carried out at manufacturer’s works in Virtual / Physical presence of Department’s representatives.(F) Physical & Chemical Test reports of i) Pump casing (ii) Impeller (iii) Shaft (iv) Shaft sleeveand Dynamic Balance certificate is to be submitted by OEM(G) Suitable size Reinforced cementconcreat (M-30) foundation with foundation bolt, Nozing Angle of size 40mm x40mm x5 mm ( Cost of RCC Foundation to be paid Extra )(H) Weather proof hood fabricated from 5mm thick UV stablised FRP sheet supported by 50 mm x 50 mm x 5 mm Angle Iron fram above pumpset to protect it from weather All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR 450 LPM with 35 mtr head 186 Supplying and fixing Inlet Breeching Connection of CI body with Gun Metal male instantaneous inlet couplings with Inbuilt NRV, Drainage Connection with 50 mm Brass gate valvecomplete with PVC blank cap and chain as required for 150mm dia Outlet with 1 no. Matching Flange (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following Ways. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 4 Way 187 SITC of installation control valve of cast iron body and brass/bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continous alarm when the wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150mm dia 188 Supplying and Fixing of PN 16 Cast Iron Dual Plate Wafer Type Check Valve / Non return valve with SS / Bronze flap complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 mm dia 189 100 mm dia 190 150 mm dia 191 200 mm dia 192 Supplying and Fixing of PN 1.6Butterfly Valve (Wafer Type) with S.G Iron Disc and confirming to IS:13095 complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 mm dia 193 100 mm dia 194 80 mm dia 195 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 6 kg 196 Supply & Fixing of CO2 type Fire Extinguisher conforming to IS:15683:2018, charged with CO2 gas (purity 99.7% conforming to IS 15222), Powder coated Internal & External Surface Manganese steel ISI marked as per IS 7285 cylinder body , Wheel type Forged brass release valve ISI Marked as per IS 3224 with Inbuilt safety release device ((Fusible plug and Rupture Disc Type), 1.0 Mtr. Metal wire braided hose having minimum bursting pressure of 140 Kgf/cm2, Horn with metallic thread connection, QR code for Product Traceability,including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSRCapacity 4.5 Kg. 197 Supplying and Fixing ofGalvanized Mild Steel fire bucket Confirming to IS: 2546 : 1974 with one coat of primer and two coat of enamel paint of approved shade on Angle Iron ( 50 x 50 x 5 mm) Stand of Size 800 x 1240 x 400 mm with MS 22 SWG Galvanized Canopy, 4 Hooks for Bucketsincludingassociated civil works etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 198 SITC of UL 10th edition / EN54 / VDS certified Addessable Manual Call point (MCP) with LED/ FIRE Indication Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 199 SITC of UL 10th edition / EN54 / VDS certified Addressable sounder with strobe light,Loop Powered / Direct powered from FACP with sound level 90 dB and programmablefrom the panel etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 200 SITC ofResponse Indicatorfor indicating the activation of the Remotely located Detector for Conventional type detectors as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 201 SITC of EN / LPCB/ UL listed / approved conventional automatic fire Alarm Rate of Rise cum fixed temperature thermister typeHeat Detectors , 12 / 24 volt D.C., visual alarm indicator (LEDs) Blink - green in stand by and Steady - red in alarm complete in all respectswith baseas required.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 202 SITC of EN / LPCB/ UL listed / approved conventional automatic fire Alarm Optical/Photoelectric type smoke detectorsof photo-optic sensing chamber, 12 / 24 volt D.C., visual alarm indicator (LEDs) Blink - green in stand by and Steady - red in alarm complete in all respectswith baseas required.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 203 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR2 x 1.5 sq.mm 204 3x 1.5 sq.mm 205 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR4 Pair 206 2 Pair 207 Supplying and fixingof CE certified and UL listed GI wire mesh cable tray made from spot welded steel wirehot dipped galvanised between 60 and 80 microns of zinc as per BS 729including horizontal and vertical bends, reducers, tees, cross members and other OEM made accessories like wall clamp, hold down clamps, Earthing terminal, brackets as required, and duly suspended from the ceiling with electro-zinc coated TF rods,etc. as required of following sizesAll as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .500 mm x 100 mm x 6 mm 208 300 mm x 100 mm x 6 mm 209 SITC of UL 10th edition / EN54 / VDS certifiedActive Repeater Panel for Fire Alarm System with inbuilt networking port (both RS485 & Ethernet),Serial port for printer,two supervisory inputs,two position key switch and USB port for programming. The Repeater Panel shall allow users to acknowledge, reset,silence, program, view hisory events.etc (All functions similar to main panel)The user interface of the repeater panel shall be same as the Main Controller with menu driven user interface with smart search.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 210 SITC of PA system Operator Console of following wattage to be installed withConventionalfire alarm systemcomplete with following capacity , channel mixing amplifier , 1 no cardioids goose neck microphone , 1 no professional grade cassette deck/ CD Player , 16 zone floor selector console ,equipment rack complete in all respects. PA system shall be coupled to the Fire Alarm System. Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 1x 240 Watt 211 SITC 6 watt Speakermounted in M S sheet box with perforated front mesh for PA and Emergency System. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 212 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRMedium point (up to 6 mtr.) 213 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRLong point (up to 10 mtr.) 214 Long point(up to 10 mtr.) 215 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRMedium point (up to 6 mtr.) 216 Long point(up to 10 mtr..) 217 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR3x 1.5 sq.mm 218 3x 2.5 sq.mm 219 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 220 2 x 6.0 sq. mm. + 1 x 4.0 sq. mm. 221 2 x 6.0 sq. mm. 222 4 x 10.0 sq.mm 223 4 x 16.0 sq.mm 224 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 225 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 226 Providing & Fixing ofof BLDC Technologyventilating fans , single phase with PVC impeller, ABS body, Double Ball bearing, automatic back lower shutterincluding making connection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .250 mm sweep with Min. Air delivery 1150 cmh, 1300 RPM 227 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 228 Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating 229 Three pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 230 50/63 A rating 231 100 A rating 232 Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 233 50/63 A rating 234 Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock,min. operation 10,000 upto 63 A rating and5000 for 100 Aratingand minimum phase termination capacity of 35 sq.mm. rigid wire, IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRTwo pole 30 mA sensitivity6A-32 A rating 235 40 A rating 236 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRGlazed door (single phase) IK-09 and IP-43 with Metal end box8 Way (8+2) 237 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box6Way(Incomer 8,Sub Incomer2+2+2) 238 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box withprovision of incomer suitable for MCB / RCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 100 A rating copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR6 Way(8+18) 239 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 240 Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,minimum width ofswitch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 25 Amp.2 Moduleswitch With LedIndicator 241 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 Amp. 2 Module Socket 242 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSRRJ-11 telephone jack Double line 243 RJ-45, Cat 6 computer jack with shutter 244 Providing & Fixing offollowing size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1 Module 245 4 Module 246 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR5 step fan regulator 2 Module 360 dgree rotating 247 Plate Earthingas per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 248 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 25mm x 6mm G.I. ( Hot Dipped) Strip 249 Supply & Laying following size B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 mm dia. 250 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1170mm(+/-10%) LED batten with min. lumen output 2200 lm 251 570mm (+/-10%) batten with min. lumen output 1000 lm 252 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Minimum lumen output 3600 lm 253 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Minimumlumen output 650 lm 254 Minimum lumen output 1950 lm 255 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 256 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR2 pair 257 Supply and Laying of PE Insulated, PVC Inner Sheathed, armoured & PVC Sheathed Telephone Cable. with 0.5 mm thick Solid Annealed Bare Copper Conductor as per IS: 8130/84 telephone cable confirming to TEC specificationsGR/WIR 06/03, Mar.-2002 in existing pipe / open trench / Cable tray / on surface including making necessary connection, testing etc. as required of size. For additional technical parameters of product / work refer Annexure A attached with this BSR50 pair 258 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 mm 259 Supplying and fixing of ISO Certified company made Krone module with base frameas per PWD specification for electrical Works, in the recess / surface made out of 16 SWG sheet steel box, front openable, having locking arrangements duly powder painted., including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .50 Pairs 260 CCTV SURVEILLANCE WORKSupply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Modular Patch Panel Loaded with Cat -6A I/O 261 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 262 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Cat 6A, Sheilded Information Outlet 263 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Single Aperture 264 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Modular Patch Panel Loaded with Cat -6A I/O 265 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 9 U Rackwith Width 600 mm & Depth 400 mm + 100 mm 266 Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent PoE Giga Ethernet Switch providing 24 x 10/100/1000 MBPSPoE Giga Ethernet ports and with min 4 SFP Giga Ports (provision for Fiber Giga connectivity) with provision of minimum Stacking of 06 Switches with minimum 370 Watt PoE Power Budget with related LAN Base Software including making connections etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 267 SITC of 2 MP IR Fixed Dome Network Camera -1/2.7″ Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.002Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Video tampering, UL, CE, FCC certified. 268 Supply Installation testing and commissioning of 32 Ch Network Video Recorder- Connect Up to 64 IP Cameras, Up to 12 Megapixels Resolution, HDMI1/VGA1 and HDMI2/VGA2 outputs provided, atleast one HDMI output with 4K (3840 × 2160), atleast one VGA output with 2K (2560 × 1440) resolution, Support H.265/MJPEG, Supports N+1 hot spare system, Supports RAID0, RAID1, RAID5, RAID6 and RAID10, Supports HDD hot swap, Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, 1 × eSATA interface, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 10 TB, Front panel: 2 × USB 2.0; Rear panel: 1 × USB 3.0, Alarm I/O 16/4, RS-232, RS-485, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface,Multiple network monitoring: Web viewer, CE, FCC, UL certified. with 30 days backup capacity asrequired. 269 SITC of professional PC alongwith printer and other accessories as required having minimum i7 processor, 8 GB graphic card 1 Tb SSD as per requirement. 270 SITC of 42 inch full HD professional LED display for CCTV monitoring. 271 External Electrical WorkS I T C of star ratedAluminium wound distribution Transformerof following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star - 1 & BIS approved as per IS 2026- 1977 & lossesas defined as per 2014 (Fourth Revision) Level-1 . including standardaccessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint,including carrying of pre-commission Testing & Charging of Transformer complete in all respect .The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including testing from CTLof discombefore charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 KVA 272 SITC of PLC Based Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stopcommands, control Relays , Ammeter & Voltmeterwith selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets: Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturer shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .20 to 40 KVA 273 Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as requiredcomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 274 Providing & Laying XLPE insulated three core ArmouredAluminiumcable for working voltage 11 K.V.(E) confirming IS :7098 P - 2withH4- Grade electrolyticaluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .3 core 150.0 Sq.mm 275 MAIN LT PANELSITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra )(d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 276 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR4 pole MCCB With Thermal Magnetic release160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 277 up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting 278 Supply and fixing of following accessories for Moulded case circuit breaker (MCCB)compatible to main MCCB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Shunt Trip Release 279 Under Voltage Release 280 Extended Rotary Handle 281 Auxiliary contact 282 Spreaders for 250A, 4 Pole MCCB 283 Spreaders upto 125A, 3 Pole MCCB 284 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 0.5 A to 5 A rating 285 Providing & Fixing of ISO certified company made Four Pole By pass Change Over Switch conforming to IS:13947(Part 3) : IEC:60947-3-1 and IEC:60947-6-1, Open execution type in the following ratings.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .100 A 286 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 0.5 A to 5 A rating 287 Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating 288 Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 289 50/63 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
14.
Health and Family Welfare #10363172 Price Bid
Tender For Electrification Work In Phc Building At Khetasar Block Osian District Jodhpur; 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 2.0 TR ISEER not less then 3.8 81 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 82 25 mm 83 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 84 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 85 150 mm dia per running inch length 86 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 87 4 kVA 88 5 kVA 89 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 90 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Surface Mounting (with extruded alumn. Housing ) 92 Minimum lumen output 1950 lm 93 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 95 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 4 kg 97 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 15 Ltr. 99 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 2 pair 101 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 102 10 Pairs 103 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 104 RJ-11 telephone jack singleline 105 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 106 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Cat 6, Un-sheilded Information Outlet 108 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 Single Aperture 110 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 112 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 Modular Patch Panel Loaded with Cat -6 I/O 114 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 115 24 Port 116 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 117 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 118 Recessed Mounting 119 Minimum lumen output 4200 lm 120 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 121 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 122 1 Mtr 123 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 3.5 x 25.0 sq.mm 125 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 126 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 127 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 128 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 130 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 131 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 132 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 133 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 134 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 135 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 136 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 137 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 138 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 139 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 140 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 141 Ring type tape wound CT 142 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 143 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Red/yellow/Green colour 145 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 146 Electrolytic grade Aluminium bus bar 6010 grade 147 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protectionwith ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA,provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 148 Two pole 100/300mA sensitivity 149 40 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
15.
Health and Family Welfare #10350409 Price Bid
Tender For supply of Digital Pet Ct Scanner As Per The Specification Except The Following , Advanced Dedicated Work Station For Pet-Ct With Oncology, Cardiology & Neurology Packages , Dual Head Injector , Dry Laser Imager , Full System Ups , Lead Glass , Additional Workstation With 1 Tb Storage Capacity , Dose Calibrator For Pet , Portable Survey Meter For Pet , Contamination Monitor For Pet , Personal Pocket Dosimeter , Tungsten Vial Shield For Carrying Isotopes , Syringe Shields For 2 & 5 Ml , Shielded Waste Decay Drum For Pet Radionuclide , L Bench With Lead Glass For Pet , Lead Lined Storage Cabinet , Interlocking Lead Bricks Including Corner Blocks , Shield Lead Carrier For Pet Doses , Light Weight Vinyl Lead Apron Of 0.5Mm Lead Equivalent , Foot Operayive Waste Bin For Pet , Dose Calibrator Shileding Ring For Pet , Dose Dispensing Unit , Decontamination Kit , Tongs 12, 18 And 24 Inch , Transport Container (Biodex Or Equivalent) , Cushioned Sofa Seats , Icu Trolley , Water Purifier (Hot And Cold) , Televisions 42 , Office Table , Dining Table With 10 Chair , Rubco Chairs , Modular Book Shelf With Glass Doors , Library Chair , Library Table , Jefferson Chair , Projector And Screen , Sound System With Fixed Mic And Wireless Mic , Pharma Refrigerator 400L , Induction Cooker , Non Revolving Chair , Refrigerator 260L , Emergency Trolley , External Lasers , 15.3 Demolishing R.C.C. Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material With In 50 Metres Lead As Per Direction Of Engineer -In-Charge. , 15.7.4 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar , 15.12.1 Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below , 15.12.2Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead: Of Area Beyond 3 Sq. Metre , 15.23.1Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm , 15.57 Dismantling Aluminium / Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Surplus Material And Stacking Of Serviceable Material With In 50 Metres Lead As Directed By Engineer - In-Charge , 15.60 Disposal Of Building Rubbish/ Malba/ Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved , 2.31Clearing Jungle Including Uprooting Of Rank Vegetation, Grass, Brush Wood, Trees And Saplings Of Girth Up To 30 Cm Measured At A Height Of 1 M Above Ground Level And Removal Of Rubbish Up To A Distance Of 50 M Outside The Periphery Of The Area Cleared , 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil , 50.2.25.1 Filling With Contractors Own Earth ( Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M As Per Direction Of Site Engineer-In-Charge , 50.4.1.1 Providing And Laying In Position Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size) Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing For Leveling Coarse Of Floor And Roof Etc. , 5.2.2Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , 50.5.33.1Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M- 20 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. Note: Cement Content Considered In This Item Is @ 330 Kg/ Cum. Excess Or Less Cement Used As Per Design Mix Is Payable Or Recoverable Separately. All Work Up To Plinth Level , 50.5.5Reinforced Cement Concrete Work In Arches, Archribs, Domes, Vaults, Shells, Folded Plate And Roof Having Slope More Than 15 Degree Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand: 3 Graded Stone Aggregate 20 Mm Nominal Size). , 50.5.33.2 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-20 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. Note:- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess Or Less Cement Used As Per Design Mix Is Payable Or Recoverable Separately. All Work Above Plinth Level Upto Floor V Level , 5.22.1 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelmild Steel And Medium Tensile Steel Bars , 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform , 5.9.1Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Foundations, Footings, Bases Of Columns, Etc For Mass Concrete , 5.9.2Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Walls (Any Thickness) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc. , 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers , 2.34.1Supplying Chemical Emulsion In Sealed Containers Including Delivery As Specified.Chlorpyriphos / Lindane Emulsifiable Concentrate Of 20% , 2.35.1.1Diluting And Injecting Chemical Emulsion For Post -Constructional Anti-Termite Treatment (Excluding The Cost Of Chemical Emulsion):Along External Wall Where The Apron Is Not Provided Using Chemical Emulsion @ 7.5 Litres / Sqm Of The Vertical Surface Of The Substructure To A Depth Of 300Mm Including Excavation Channel Along The Wall & Rodding Etc. Complete: With Chlorpyriphos /Lindane E.C. 20% With 1% Concentration , 24.2Providing And Fixing Double Scaffolding System (Cup Lock Type ) On The Exterior Side Of Building/Structure, Upto 25 Metre Height, Above Ground Level, Including Additional Rows Of Scaffolding In Stepped Manner As Per Requirement Of Site, Made With 40 Mm Dia M.S. Tube, Placed 1.5 Metre Centre To Centre, Horizontal & Vertical Tubes Joint With Cup & Lock System With M.S. Tubes, M.S. Tube Chakkus, M.S. Clamps And Staircase System In The Scaffolding For Working Platform Etc. And Maintaining It In A Serviceable Condition For Execution Of Work Of Cleaning And / Or Pointing And / Or Applying Chemical And Removing It Thereafter. The Scaffolding System Shall Be Stiffened With Bracings, Runners, Connecting With The Building Etc, Wherever Required, If Feasible, For Inspection Of Work At Required Locations With Essential Safety Features For The Workmen Etc., Complete As Per Directions And Approval Of Engineer-In-Charge. Note: - ( 1) The Evaluational Area Of The Scaffolding Shall Be Measured For Payment Purpose, (2) The Payment Will Be Made Once Only For Execution Of All Items Of Such Works. , 6.26.2Brick Work With Common Burnt Clay Selected F.P.S (Non Modular ) Bricks Of Class Designation 7.5 In Exposed Brick Work Including Making Horizontal And Vertical Grooves 10 Mm Wide 12 Mm Deep Complete In Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand)Above Plinth Level And Upto Floor V Level , 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x20cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. , 50.6.1.8 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x15cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In: Cm 1:6 ( 1 Cement : 6 Coarse Sand Etc Complete , 50.6.3.2 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x10 Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level For 10 Cm Thick Wall In : Cm 1:6 ( 1 Cement : 6 Coarse Sand) Including Cost Of Scaffolding Complete , Providing And Fixing Gi Chicken Wire Mesh 24 Gauge & 12 Mm Mesh And 300 Mm Width For Construction Joints And Chasing In Brick Work For Electrical Conduits Or Water Supply Pipes Including Cement Slurry And Pegs/Nails With Nailing Machine As Required Before Plastering Etc. Complete , 13.1.1Cement Plaster12 Mmof Mix: 1:4 ( 1 Cement : 4 Fine Sand) , 13.7.1Cement Plaster 12 Mmfinished With A Floating Coat Of Neat Cement Of Mix: 1:3 ( 1 Cement : 3 Fine Sand) , 13.12- 18 Mm Cement Plaster In Two Coats Under Layer 12 Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand )And A Top Layer 6 Mm Thick Cement Plaster 1:3 ( 1 Cement : 3 Coarse Sand) Finished Rough With Sponge. , 22.5Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : A) First Layer Of Slurry Of Cement @ 0.488 Kg/Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg/Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. B) Second Layer Of Slurry Of Cement @ 0.242 Kg /Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg/ Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. , 11.37Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer), Of 1St Quality Conforming To Is : 15622, Of Approved Make, In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. , 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. , 11.41.3 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 800X 800 Mm , Od31976/2023_2024Providing And Fixing First Quality Vitrified Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , 11.48.2 Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade (0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg). Including Filling /Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge. Size Of Tile 600X600 Mm , 11.48.3Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade (0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg). Including Filling /Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge.Size Of Tile 800X800mm , 11.55.1 Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge :Flamed Finish Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , 50.9.1.1Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood , 50.9.2.1Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineerin - Charge. Using Anjili/ Jack Wood , 21.1.1.2 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately): For Fixed Portionpowder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , 21.1.2.2 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge.Pre- Laminated Particle Board With Decorative Lamination On Both Sides , Od31977/2023_2024 Supplying And Fixing Flush Door Shutter, Shutter Of Required Size, Thickness 30Mm Thick, Finished With 1 Mm Laminate Of Approved Shade With 9 X 16 Clear Glass Vision Panels As Per Design Including Necessary Hinges , Od31978/2023_2024 Frosted Film - Supply And Installation Of 3M Make Frosted Film Pattern Throughout All The Internal Glass Panels Wherever Required Of Approx. 1.5 M Height As Per The Approved Pattern. , Od31979/2023_2024 Providing And Fixing Extruded Section Body Tubular Type Universal Hydraulic Door Closer(Having Brand Logo With Is: 3564, Embossed On The Body, Door Weight Upto 36 Kg To 80 Kg And Door Width From 701 Mm To 1000 Mm), With Double Speed Adjustment With Necessary Accessories And Screws Etc. Complete , Od31980/2023_2024 Providing And Fixing 4.00 Mm Thick Acp Sheet For Cupboard Including All Cost, Conveyance, Labour Charges Etc Complete , 21.3.1 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 4.0 Mm Thickness , 12.45.2 Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms/ Sqm (Both Side Inclusive) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37 Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50 Mm Long With 6 Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25 Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5X25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound, Jointing Tapes, Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With: 12.5 Mm Thick Tapered Edge Gypsum Fire Resistant Board Conforming To Is; 2095-Part I , 12.54.1 Providing And Fixing Gi Clip In Metal Ceiling System Of 600X600 Mm Module Which Includes Providing And Fixing C Wall Angle Of Size 20X30x20 Mm Made Of 0.5 Mm Thick Pre Painted Steel Along The Perimeter Of The Room With Help Of Nylon Sleeves And Wooden Screws At 300 Mm Center To Centre, Suspending The Main C Carrier Of Size 10X38x10 Mm Made Of G.I Steel 0.7 Mm Thick From The Soffit With Help Of Soffit Cleat 37X27x25x1.6 Mm, Rawl Plugs Of Sixe38x12 Mm And C Carrier Suspension Clip And Main Carrier Bracket At 1000 Mm C/C. Inverted Triangle Shaped Spring Tee Having Height Of 24 Mm And Width Of 34 Mm Made Of Gi Steel 0.45 Mm Thick Is Then Fixed To The Main C Carrier And In Direction Perpendicular To It At 600 Mm Centers With Help Of Suspension Brackets. Wherever The Main C Carrier And Spring T Have To Join, C Carrier And Spring T Connectors Have To Be Used. All Sections To Be Galvanized @ 120 Gms/Sqm (Both Side Inclusive), Fixing With Clip In Tiles Into Spring T With :Gi Metal Ceiling Clip In Plain Beveled Edge Global White Color Tiles Of Size 600X600 And 0.5Mm Thick With 25 Mm Height, ,Made Of G.I Sheet Having Galvanizing Of 100 Gms/ Sqm (Both Sides Inclusive) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns (Minimum), Including Factory Painted After Bending . , 12.58.1 Providing And Fixing Tiled False Ceiling Of Approved Materials Of Size 595X595 Mm In True Horizontal Level, Suspended On Interlocking Metal Grid Of Hot Dipped Galvanized Steel Sections (Galvanized @ 120 Grams/ Sqm, Both Side Inclusive) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick (Minimum) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet, 1200 Mm Long Space Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel To Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting/Making, Opening Of Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Of Size 27 X 37 X 25 X 1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gi Adjustable Rods With Galvanized Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. 8Mm Thick Fully Perforated Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Autoclaving Process To Give Stable Crystalline Structure With Minimum Compressive Strength 225 Kg/ Sq. Cm, Bending Strength 100 Kg/Sq. Cm, Of Size 595X595 Mm, Having Perforation Of Dia, 10 Mm With Minimum Perforated Area 18% With Non Woven Tissue On The Back Side, Having An Nrc (Noise Reduction Coefficient) Of 0.85, With 50 Mm Thick Rockwool Of 48 Kg/Cum Backing. , 21.4.2Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is: 6315, Having Brand Logo Embossed On The Body / Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors, Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Engineer -In- Charge.With Brass Cover Plate Minimum 1.25 Mm Thickness , 21.13 Providing And Fixing 100 Mm Brass Locks ( Best Make Of Approved Quality ) For Aluminium Doors Including Necessary Cutting And Making Good Etc. Complete , 50.9.11.1Providing And Fixing Thomson Multi Wood Board Or Equivalent Make Paneling 12 Mm Thick, To Frame, Backing Or Studding With Screws Etc. Complete ( Frames, Backing Or Studding To Be Paid Separately) As Per The Direction Of Site Engineer-In-Charge. , 50.9.12.1 Providing And Fixing Thomson Multi Wood Board Or Equivalent Make, In Shelves With Screws And Fittings Wherever Required, Edges To Be Painted With Polyurethane Primer (Fittings To Be Paid Separately) As Per The Direction Of Site Engineer-In-Charge. , 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work , 13.69.1 Polishing On Wood Work With Ready Mixed Wax Polish Of Approved Brand And Manufacture: New Work , 13.80Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , 13.83.2Wall Painting With Premium Acrylic Emulsion Paint Of Interior Grade, Having Voc (Volatile Including Applying Additional Coats Wherever Required To Achieve Even Shade And Colour.Two Coats , 13.47.1Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) , 10.16.3 Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Electric Resistance Or Induction Butt Welded Tubes , Od31981/2023_2024Roofing Sheet With Sandwich Puf Roof Panel With 0.40 Mm Or Nearest Size Pre Painted Galvalume Sheet At Top & Bottom , 30 Mm Or Nearest Size Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete , Od31982/2023_2024 Wall Cladding With Sandwich Puf Wall Panel With 0.40 Mm Or Nearest Pre Painted Galvalume Sheet At Top &Bottom , 30 Mm Or Nearest Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete. , Od31983/2023_2024 Providing At All Heights, Levels And Locations 0.45 Mm Thick Galvalume Sheet Of Alloy 31500/31000/40800, Conforming To Is 1254, Is 737, Is 2676. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Ss Screws Of Size 5.5X65 Mm With Epdm Seal Complete Upto Required Pitch In Horizontal, Vertical Or Curved Surfaces I/C Cutting To Size And Shape Where Required As Per The Direction Of Engineer-In-Charge. The Rate Shall Be Inclusive Of All Screws, Seal, Ridge, Labour, Scaffolding, Machinery For Fixing And Approved Sealant Where Required Etc. But Excluding The Cost Of Purlins, Rafters And Trusses. , 17.81Providing And Fixing Floor Mounted, White Vitreous China Single Piece, Double Traps Syphonic Water Closet Of Approved Brand/Make, Shape, Size And Pattern Including Integrated White Vitreous China Cistern Of Capacity 10 Litres With Dual Flushing System, Including All Fittings And Fixtures With Seat Cover, Cistern Fittings, Nuts, Bolts And Gasket Etc Including Making Connection With The Existing P/S Trap, Complete In All Respect As Per Directions Of Engineer-In-Charge. , 17.2.2 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , 17.7.1 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps , 50.17.1.2 Supplying And Fixing Cp Towel Rod 45Cm Or Nearest Available Length Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge , 50.17.1.5Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 50.17.1.1 Supplying And Fixing Stainless Steel Soap Dish Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 17.31 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Od33878/2023_2024 Supplying And Fixing Stainless Steel Mirror Finished H Type Handles Including Material Cost, Conveyance And Fixing Charges Etc Complete. , 50.18.7.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 15Mm Dia 12Kgf/Cm2 -Internal Work- Exposed On Wall , 50.18.7.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mm Dia 10Kgf/Cm2- Internal Work - Exposed On Wall , 50.18.8.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer- In- Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 15 Mm Pipe 12 Kgf/ Cm2 , 50.18.8.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 32 Mm Pipe 10Kgf/Cm2 , 50.18.8.9.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chased And Making Good The Wall Etc. 110 Mm Pipe 6Kgf/Cm2 , 50.18.9.8.2 Providing And Fixing Pvc Pipes Includings Of Pipes With One Step Pvc Solvent Cement, Trenching And Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 75 Mm Dia 4 Kgf/Cm2 , 18.7.2 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer -In-Charge. Internal Work - Exposed On Wall20 Mm Nominal Outer Dia Pipes , 18.7.3Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer -In-Charge. Internal Work - Exposed On Wall 25 Mm Nominal Outer Dia Pipes , 18.8.2Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes& Fittings, With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc.20 Mm Nominal Outer Dia Pipes , 18.8.3 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes& Fittings, With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 25 Mm Nominal Outer Dia Pipes , Od31984/2023_2024 Providing And Fixing 24 Mm Thick Factory Made Pvc Door Shutters Made Of Styles And Rails Of A Pvc Hollow Section Of Size 59 X 24 Mm And Wall Thickness 2 Mm With Inbuilt Edging On Both Sides. The Styles And Rails Mitered And Joint At The Corners By Means Of M.S. Galvanized/Plastic Brackets Of Size 75 X 220 Mm Having Wall Thickness 1.0 Mm And Stainless Steel Screws. The Styles Of The Shutter Reinforced By Fixing Galvanized M.S. Tube Of Size 20 X 20 Mm And 1 Mm Wall Thickness. The Lock Rail Made Up Of H Section, A Pvc Hollow Section Of Size 100 X 24 Mm And 2 Mm Wall Thickness,Fixed To The Shutter Styles By Means Of Plastic/Galvanized M.S. U Cleats. The Shutter Frame Filled With A Pvc Multi-Chambered Single Panel Of Size Not Less Than 620 Mm, Having Over All Thickness Of 20 Mm And 1 Mm Wall Thickness. The Panels Filled Vertically And Tie Bar At Two Places By Fixing Horizontally 6 Mm Galvanized M.S. Rod And Fastened With Nuts And Washers, Complete As Per Manufacturers Specification And Direction Of Engineer-In-Charge( For W.C. And Bathroom Door Shutter). , Od31985/2023_2024 Supplying And Fixing Name Board Of Various Sizes Using Foam Sheet Board Including Lettering As Per The Direction Of Departmental Officers Including Cost, Conveyance And Fixing Charges Etc Complete. 45X14cm Size , Od31986/2023_2024 Supplying And Fixing The Name Board Of Size 80 X 30 Using Acp Board With Acrylic Lettering Including Cost, Conveyance And Labour Charges For Lettering And Fixing Etc Complete , Od31987/2023_2024 Supplying And Fixing Inaugration Board Using Granite Slab Including Lettering As Per Direction Of Departmental Officers Including Cost Of Granite, Lettering And Fixing Charges Etc Complete. Size: 100X84cm , Supplying And Fixing Skylight Of Size 1.2Mx 1.8M With Designed Acrylic Sheet Including 4 Numbers Led Tube As Per The Direction Of Engineer In Charge , Od31989/2023_2024 Computer Chair The Medium Back Adjustable Revolving Chair Made With Mesh Back Within Built Handle In The Nylon Finish, The Back Is Designed Extra Lumber Support. The Seat Have Provided Seat Cover In Pp Made With 12Mm Hot Pressed Ply And Pu Moylded Foam. The Tilting Mechanism Should Be Synchro-Tilt Mechanism As Per International Ergonomics Standards Any Position Locking. The Base And Pin Wheels Are Made In The Nylon. 120Mm H Gas Lift Should Be Provided With Tower Bellow , Od31990/2023_2024 High Back Chair Made With Feather Foam Seat & Mesh Back With Lumber Support. , The Gas Lift Mechanism Should Be Tested As Per Bifmastandards. The Pedestal Should Be Five Legged Injection Mouldedin Black 30% Glass –Filled Nylon And Fitted With 5 Nos Twin Wheel Castors. The Castors Of The Chairs Should Be Glass Filled, It Should Have Synchro Any Anglelocking Arrangement , Od31991/2023_2024Providing And Fixing Trap Doors For Access To The Areas Above False Ceiling. The Trap Door Shall Have An External Frame Made Of Powder Coated Aluminium Channel On Which The Shutter Is Hinged. Shutter Shall Be Made 3 Mm Thick Acp Sheet Shutter External Frame Of Shutter Made Of Powder Coated Aluminium Channel. Concealed Heavy Duty Hinges Shall Be Used To Mount The Shutters And Locking Shall Be Provided. The Shutter Shall Be Moulded In Level With The False Ceiling Forming A Groove All Around. Sufficient Number Of Hinges And Locks Shall Be Provided To Avoid Sagging Of The Shutter. Key Also Shall Be Supplied. No Extra Rate Shall Be Provided For Suspenders Or Frame Works All Round For Linking The Trap Door To Gyp Board /Any Other False Ceiling. The Rate Including All Labour Charges ,Material Charges Ect Complete. , Od33559/2023_2024 Supplying And Laying Polyster , Washable And Stainfree Cloth(Bio-Active Fabric Washable Germfree-Suitable For Icu Room) Curtain System With Maximum Curtain Cloth Height 230Cm (Top 30 Cm White Colour Net And 200Cm Light Blue Colour As Per Approval) Stitching With Stifiner Tape,Pleats,Ironing And Laying In Icu Room Around Each Bed Using Pvc Runner With Hooks&Stopper For Hanging/Sliding Etc. As Per The Direction Of Engineer In Charge Including Conveyance To Site , Laying In Line And Level , Sealing All Cuttings In False Ceiling With Powder Coated Ms Cup ,All Leads And Lifts Including All Labour Charges Etc. Complete.(Unpleated Length Of The Cloth Maesurement Will Be Considered For Payment Also The Bottom And Top Foldings Will Not Be Considered In Cloth Measuremnet)/Supplying And Fixing Powder Coated 20Mm Dia. Gi Round Tube Hanging Support Of Required Length (App. Length 1.10M) One End Fixing From Slab By Using 6Mm Dia. Expansion Bolt At A Distance Not More Than 2 M, C/C Down End Fixed To Powder Coated Aluminium Channel Frame 45X20mm X1mm Thick Section By Using Ss Screw As Per The Direction Of Engineer In Charge Including Conveyance To Site, Laying In Line And Level ,Sealing All Gaps In False Ceiling Due To Hanging Supports ,All Leads And Lifts, Including All Labour Charges Etc. Complete. , Od33560/2023_2024 Providing And Fixing Vertical Blinds As Per The Direction Of Engineer In Charge , Furniture& Other Works: Lead Lined Door Shutters: 2Mm Lead Lined Door Shutterswithsolid Cored(30Mm) Lead(2Mm) Lined Flush Door Side Hung Two Rebated Shutters With Plywood(6Mm) & Laminated (1Mm) On Both Sides And All Accessories ( Ss Hinges (4 Nos), Tower Bolt , Ss Handles Etc..) , Lead Lined Door Frames: Lead(2Mm) Lined Flush Door Side Hung Single Shutter With Plywood(6Mm) &Laminated (1Mm) On Both Sides And All Accessories(Lead Sheet Should Overlap Door Frame & Wall )Includingproviding Wood Work In Frames Of Doors And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length , Using Good Quality Anjili Wood /Jack Wood (Frame Size 12 Cm X 8 Cm) , Wood Frame For Fixing Lead Glass (Lead Sheet Should Overlap Door Frame & Wall ) , Steel Cupboard (Godrej) For Storage 6Ft Tall 3 Feet Width , Providing And Fixing 2.0Mm Th. Vinyl Floor With Rubber Based Adhesive Over Clean And Smooth Surface Including Finishing By Rolling A Light Roller All Complete. , Wiring For Group Controlled (Looped) Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point ( Without Independent Switch Etc.) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group B , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. Group C , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X 2.5 Sq. Mm + 1 X 2.5Sq. Mm Earth Wire , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2 X 4 Sq. Mm + 1 X 4Sq. Mm Earth Wire , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required. 4 X 6 Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required. 3 X 1.5 Sq.Mm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required. 3 X 2.5Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required. 3 X 4 Sq. Mmm , Switches & Sockets: Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5/6 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 2 Way 5/6 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15/16 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3 Pin 5/6 Amp Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 6 Pin 15/16 Amp Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 20/25 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 6 Pin 20/25 Amp Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Bell Push , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.1 Or 2 Module (75Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 3 Module (100Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 6 Module (200Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 8 Module (125Mmx125mm) , Supplying And Fixing Call Bell/ Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Ceiling, Wall And Exhaust Fans: Extra For Fixing The Louvers/ Shutters Complete With Frame For An Exhaust Fan Of All Sizes , Charges For Cutting Holes Suitable For Accommodating Exhaust Fans Up To 305Mm Sweep Including Plastering Color Washing Etc. As Required. , Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage Connection Testing, Commissioning Etc. As Required. Upto 450 Mm Sweep , Sitc Of 400Mm Sweep Meduim Duty Wall Fans With Metallic Vanes (Make: M/S Almonard/ Crompton/Bajaj Or Equivalent) , Supply, Conveyance, Installation, Testing And Commissioning Of Ceiling Fans Of The Following Sizes Using Standard Accessories Excluding Resistance Type Regulator, Wiring The Down Rod With 16/0.20Mm Pvc Insulated And Pvc Sheathed 650/1100V Grade 3 Core Round Copper Conductor Flex Wire Or With Extended Original Wiring Etc. As Required. 1200Mm Sweep -5Star Rated Bldc Ceiling Fan Complete With 300Mm Down Rod , Canopies, Shackles And Blades Working On 230V/240V Single Phase A/C , Supply Of 300/305 Mm Sweep Light Duty Exhaust Fan In Metal Frame Working On230 Va/C , Db Mcb Switch Gear: Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 4 Way (8+12) - Three Phase Double Cover (Ip 42/43) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 6 Way (8+18) - Three Phase Double Cover (Ip 42/43) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 4 Way (8+12) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 6 Way (8 + 18) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) , Supplying And Fixing Following Way Prewired Sp&N Mcb Distribution Board Of Steel Sheet For 240 Volts On Surface/ Recess Complete With Loose Wire Box, Terminal Connectors For All Incoming And Outgoing Circuits, Duly Prewired With Suitable Size Fr Pvc Insulated Copper Conductor Up To Terminal Blocks, Tinned Copper Bus Bar, Neutral Link, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/ Rccb/Isolator)2+12 Way, Double Door , Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral), 240 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Four Pole, (Three Phaseand Neutral), 415 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Dbcomplete With Connections, Testing And Commissioning Etc. Asrequired. 63 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, (Three Phase And Neutral), 415 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Amps , Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole , Supplying And Fixing Following Rating, Three Pole, Mcb63 A Rating, 3 Pole, Mcb , Supplying And Fixing Following Rating, Three Pole, Mcb 40 A Rating, 3 Pole, Mcb , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required 100 Amp, 30 Ka 4 Pole , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Panel Assembly Made Out Of 1.6Mm Crca Powder Coated Sheet As Required. 320A/400A, 50/55 Ka (Ics=100%Icu), 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Existing Panel Assembly As Required. 16A -100A, 35/36 Ka (Ics=100%Icu), 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Cable Supply Laying And Termination: Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Cable Tray As Required. Above 35 Sq. Mm And Upto 95 Sq. Mm (Clamped With 25X3mm Ms Flat Clamp) , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc.As Required.4 Core 185 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 240 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 300 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 25 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 50 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 10 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 16 Sq Mm With Factory Made Clamp , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required. 3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 70 Sq Mm , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armoured Aluminum Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required. 3.5 Core 70 Sq Mm , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required.225Mm Width X 50Mm Depth X 1.6Mm Thickness , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays Bends With Perforation Not More Than 17.5%,, Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required 225 Mm Width X50 Mm Depth X 1.6 Mm Thickness , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required. 50 Sqmm , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 3 1/2X 70 Sq. Mm (38Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 3 1/2X 95 Sq. Mm (45Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 3 1/2X 185 Sq. Mm (57Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 3 1/2X 240 Sq. Mm (62Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 10 Sq. Mm (25Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 16 Sq. Mm (28Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 25 Sq. Mm (28Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.4 X 50 Sq. Mm (35Mm) , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required.16 Sq.M , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required. 25 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required.10 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 50 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 25 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 16 Sq.M , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 10 Sqmm , Supplying And Providing Earth Clamps For Siemens/ Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required.25Sq - 95Sq Mm With 20 Mm Wide X 1.20 Mm Thick Clip , Supplying And Providing Earth Clamps For Siemens/ Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required. 4Sqmm-16 Sq Mm With 12 Mm Wide X 1 Mm Thick Clip , Earthing & La: Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required 2.65 Mm Copper Conductor (12 Swg) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required 3.15 Mm Copper Conductor ( 10 Swg) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required 4.00 Mm Copper Conductor ( 8 Swg) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 2.65 Mm (12 Swg) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 3.15 Mm (10 Swg) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 4.00 Mm (8 Swg) , Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal/ Coke And Salt As Required. , Supply And Clamping The Following Size Of Strips On Surface Of Wall/ Parapet/ Existing Cable Tray Using Clamps Fabricated From 20 X 3 Mm Gi Flat Duly Painted Or Heavy Duty Gi Spacer Saddles Spacing Of Clamps Not Exceeding 1 M, Making Good The Damages, Color Washing Etc. As Required (For Horizontal Run) 25 X 3 Mm Copper Strip , Supplying, Threading, Laying And Jointing Of The Following Sizes Of B Class Gi Pipe With All Required Accessories In Ground In Trench As Protective Covering To Earth Leads 40Mm Dia , Supplying And Laying 25 Mm X 5 Mm Copper Strip At 0.50 Meter Below Ground As Strip Earth Electrode, Including Connection/ Terminating With Nut, Bolt, Spring, Washer Etc. As Required. (Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt & Spring Washer Spaced At 50Mm) , Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required 2.00 Mm Copper Conductor ( 14 Swg) , Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia 300 Mm Long, G.I. Tube,Having Single Prong At Top, With 85 Mm Dia 6 Mm Thick G.I. Base Plate Including Holes Etc. Complete As Required. , Fixing Of Lightning Conductor Finial (Single Prong) With Base Plate Including Holes Etc. Complete As Required , Jointing Copper / G.I. Tape (With Another Copper/ G I Tape, Base Of The Finial Or Any Other Metallic Object) By Riveting / Nut Bolting/ Sweating And Soldering Etc As Required. , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required.(For Horizontal Run) , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required.(For Vertical Run) , Fixing Of Copper/ G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required.(For Horizontal Run) , Fixing Of Copper/ G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required.(For Vertical Run) , Providing And Fixing Testing Joint, Made Of 20 Mm X 3 Mm Thick G.I. Strip, 125 Mm Long, With 4 Nos. Of G.I. Bolts, Nuts, Chuck Nuts And Spring Washers Etc. Complete As Required. , Providing And Laying G.L. Tape 32 Mm X 6 Mm From Earth. Electrode Directly In Ground As Required , Laying Copper/ G.I. Tape 32 Mm X 6 Mm From Earth Electrode Directly In Ground As Required. , Led Fixtures S&F: Supply Conveyance, Installation, Testing And Commissioning The Light Fittings Of Following Types Made From Crca Sheet 0.5Mm Thickness With All Accessories And Lamps Directly On Wall And Giving Connections With 16/0.20 Mm 3 Core Pvc Insulated And Sheathed Round Copper Conductor Flex Wire Or Extending The Original Wiring And Giving Connections As Required 1200 Mm 1X20w Led Lamp With Box Type Fixture , Supply & Installation Of Light Fittings On Tw Round Block
Supply, Conveyance Installation Testing And Commissioning The Light Fittings Of Following Types Made Of Crca With 0.5Mm Thickness Complete With All Accessories And Lamps Etc. Directly On Wall Or Ceiling With Pvc Round Block Neatly Painted To Suit The Fitting And Giving Connection With Required Length Of 16/0.20Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss And Giving Connections As Required.1200Mm 1X20w Led Lamp With Box Type Fixture , Supplying And Fixing Of Recess Mounted Led Luminaire With Full Diffuser Type Upto 36 W (Max), 2X2 Led, Cool White, 5700K, White Powder Coated Crca Housing, Wipro Crco10r038hp57gl1 Or Bajaj Bzrsql 36W Gzi Cw Or Equivalent , Frame For Fixing Recess Mounted Led 2X2 Ft Luminaire 608 Mm X 608 Mm , Supplying And Fixing Ofrecess Mounted Circular Led Retrofit Downlighter, 15W, Powder Coated White Finish, Bpslr 15W Wh Bajaj Or Equivalent , Supplying And Fixing Of 6 / 7 W Pin Type Led Bulb In The Existing Angle Batten Etc As Required (Philips, Wipro Or Similar Superior Make) , Supply Of 18W Led Downlighter With A Nominal System Lumen Output Of Minimu 500 Lumens. System Wattage Should Not Exceed 18W. The Luminaire Shall Have A Rated System Lifetime Of 50,000 Burning Hours. The Luminaire Should Have A Color Temperature Of 5700K And Cri>80. Driver Of The Luminaire Shall Have Thd < 10% And Pf > 0.95. Housing Shall Be Crca Powder Coated With Pmma Diffuser.Driver Shall Have 85% Efficiency. Similar To Wipro Make Ld06-221-Xxx-57-Xxor Eqivalent , Supply Of 12W Led Downlight, High Efficiency With A Nominal System Lumen Output Of 760 Lumens. Luminaire Wattage Should Not Exceed 12W. The Luminaire Should Have Acri > 80. Driver Of The Luminaire Shall Have Thd < 10% And Pf > 0.9. Slim Led Batten In Aluminium Housing And Decorative End Caps. Robust Driver With Wide Voltage Range 100-240 Volts And Inbuilt Protection. Aesthetically Designed Mirror Led Light Fixture Of 4000 K,Of Surface Mounting Which Provides Soft-Light And Glare Free Symmetrical Illumination. Simialr To Model Number Ld07- 131-060-40-Wh Of Wipro Make Or Equivalent. , Fire Alarm, Fire Extinguisher & Safety: Abc Powder Type Fire Extinguisher With Nabl Approval, Fights Class A, B, C And Electrically Started Fires. , Fire Extinguisher Carbon Di-Oxide Type With Nabl Approval , Supplying, Installing, Testing And Commissioning Ofconventionalsingle Action Manual Call Point , Supplying, Installing, Testing And Commissioning Of Conventional Hooter With Builtin Flasher Lightwith Base Ul/En Listed. , Supplying, Installing, Testing And Commissioning Of 2 Core X 1.5 Sqmm Fr Pvc,Multistrand Copper Cu Ar Cable Confirming To Is Standards And Specifications. Make: Polycab / Century , Providing Installating, Connecting, Testing And Commissioning Heat Detectors Type With Mounting Base, Blinking Ledas Required Complete And Integration , Supplying, Installation, Testing And Commissioning Ofconventional Photoelectric Smoke Detectorsas Required To Connect With Existing System , Providing And Fixing Of Response Indicator As Required , Conventional Single -Zone Fire Panel With Batteries, Battery Charger Mimic Diagram Etc , Supply And Providing2/3 Mm Thick Sythetic Type And 1 M Wide Electrical Grade Chequered Type Rubber Mat To Withstand 3.3 Kv Dielectric Strength Conforming To Is 5429/1969. , Supply And Providing Laminated First Aid Chart Duly Framed And Placed In A Conspicuous Location For Clear Vision. , Numbering & Lettering: Numbering Of Ceiling Fan / Exhaust Fan/ Fluorescent Fittings As Required. , Hvac Works: Copper Pipe With Superlon Insulation For Suction And Discharge , Pvc Drain Pipe With Proper Insulation , Weather Proof 3 Core Copper Wire For Indoor To Outdoor Connecting Cable (Size As Per The Requirement Of Ac Manufacturer) , Core Cutting Charges Including Making The Surface Finished With Plastering And Painting, Making Good And Finishing With Matching Surface After Housing Pipe Etc. , Supporting Stand For Fixing Outdoor Unit(Powder Coated) , 4 Kva Voltage Stabilizer Wall Mount Type With Time Delay, High& Low Voltage& Thermal Overload Protection, Input Voltage: 170-220V, Output Voltage : 200-240V, High Voltage Cut Off : 240V, Efficiency: >95%, Frequency : 50Hz, V Guard Vg 500 Or Equivalent , Supply, Conveyance Testing And Commissioning Of 2 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar/Lg(Dual Inverter Type)/Voltas/Mitsubishi Or Superior Superior Brands, Cooling Capacity 6000 Kw/Hr With Rotary/Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500/450, Led/Lcd Display , Supply, Conveyance Testing And Commissioning Of 1 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar/Lg(Dual Inverter Type)/Voltas/Mitsubishi Or Superior Brands, Cooling Capacity 3000 Kw/Hr With Rotary /Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500/450, Led/Lcd Display , Sitc Of 19 Mm Thick Nitrile Rubber For Under Deckinsulation , Charges For Cutting Holes Suitable For Accommodating The Supply Ducts Including Plastering, Color Washing Etc. As Required. , Outdoor Unit Stand With Ribbed Rubber Pads , Electrical Cabling Between Indoor And Outdoor Units, With Required Size Cables/Wires(Havells/Rr Kabel/V-Guard Frls Wires) , Supply, Installation, Testing And Commissioning Upvc Drain Pipe 6Kg/Sq.Cmof Suitable Dia Connecting The Drain Pan Of The Indoor Units To Nearest Drain Point, With 12Mm Thick Closed Cell Elastomeric Insulation As Per Specification , Motorized Volume Control Damper For Individual Operation Of Ductable Split Air Conditioners , Supply And Fixing Of Canvas Connection And Ribbed Rubber Pads As Vibration Isolators , Providing And Fixing Of Thermal Insulation Lining With 13Mm Thick Nitrile Rubber Closed Cell Type With Adhesive, On Supply Duct. , Providing And Fixing Of Acoustic Duct Lining With 10Mm Thick Nitrile Rubber Open Cell Type Inside The Ducts , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminum Continuous Grilles 150Mm High For Return Air As Per Spec , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminimum Continuous Grilles 150 Mm High For Supply Air With Aluminum Damper As Per Spec , Supply, Installation, Testing And Commissioning Of Volume Control Duct Damper Made Of Extruded Aluminum For Ducts/Collars To Be Provided With Suitable Links, Lebers And Quadrants For Manual Control Of Volume Of Air Flow And For Proper Balancing Of The Air Distribution In The Main Duct Complete With Neoprene Rubber Gaskets, Nuts, Bolts, Screws Linkages, Flanges Etc., As Per Specifications. , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges ,Supports, Gi Rods , Anchor Bolts ,Gi Nuts And Bolts, Pvc/ Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof /Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 24G , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges ,Supports, Gi Rods , Anchor Bolts ,Gi Nuts And Bolts, Pvc/ Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof /Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 22G , Supply, Installation, Testing And Commissioning (Sitc) Of 11 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu/Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring(Max 3M From Isolator) And Control Cabling(Indoor To Outdoor),Thermostat Wiring, High-Low Pressure Cut Out,Suitable For Three Phase 440V Supply Etc Complete As Required , Suitable De- Humidifier Units : Extraction At Least 35 Litres/Day, Compresor : Rotary, Air Flow : At Least 220M3/Hr, Reputed Brand, Input 230V Ac , Ssb And Ups Panel:Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb (0-500)V Class 1 With 90 Deg Defl. Scale (0-200)A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200/5 A 5 Va Class .5S Cts On/Off Indication Lamp, Digital Multi-Function Meter To Read V,A.Hz,Pf,Kwh, Incomer 200A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos Out Goings 160 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 2 Nos 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 2 Nos.The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specifications.Pn Busbar Chamber With Copper Busbar. , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switch Gears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type Digital Multi-Function Meter To Read V,A.Hz,Pf,Kwh Incomer 160A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 160A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 125A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos %Icu= 25Ka) - 2 Nos 63A Fp Mccb - 3 Nos The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification. , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Panel Assembly Made Out Of 1.6Mm Crca Powder Coated Sheet As Required. 320A/400A, 50/55 Ka (Ics=100%Icu), 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Statutory Approvals: Charges For Obtaining Electrical Inspectorates Approval Including Scheme Apporval And Final Approval And Regularizing With Kseb , Elv: Supplying And Drawing Following Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor,Unarmored Telephone Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 2 Pairs , Supplying And Drawing Co-Axial Tv Cable Rg-6 Grade, 0.7 Mm Solid Copper Conductor Pe Insulated, Shielded With Fine Tinned Copper Braid And Protected With Pvc Sheath In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20Mm , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Telephone Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Tv Antenna Socket Outlet , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 25Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 32Mm , Supplying And Laying Of Following Pair Armoured Telephone Cable Through Wall/Tray With All Acessories As Required For Complete Installation And As Instructed By Engineer In Charge/Consultant And Making Good All Damages Made For Installation. 5 Pair , Kronebox-Supply,Erection,Testingandcommissioningoffollowingpairkronewithbox Including Mounting Frame, Enclosure Of Isi Grade With Lockable Front Cover With All Accessories Required For For Complete Installation In Wall As Directed By The Engineer In Charge. 10Pair , Supply, Installation, Testing And Commissioning Of Basic User Phone With Necessary Connection As Required For Complete Installation As Directed By The Engineer In Charge. , Supplying And Drawing Of 6 Core Sm Armoured Optical Fibre Cable (Ofc) Through Wall / Tray With All Acessories As Required For Complete Installation And As Instructed By Engineer In Charge / Consultant And Making Good All Damages Made For Installation. , Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/Recessed Steel/Pvc Conduit As Required 1 Run Of Cable , Cat 6 Rj 45 Computer Jack Modular Socket Outlet , Supplying And Drawn Of Utp 4 Pair Cat 6A Lan Cable In The Existing Surface/Recessed Steel/Pvc Conduit As Required 1 Run Of Cable , Cat 6A Rj 45 Computer Jack Modular Socket Outlet , 24-Port Gigabit Manageable Smart Network Switch With 2 Sfps. Rack Mountable , Patch Panel - 24-Port Patch Panel With Cable Tray. Rack Mountable , 9U Rack- Wall Mountable Including 4X 6Amp Power Distribution Box , Supply Of Branded 1Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 2Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 3Mtr Patch Cords With Cat 6 Cable. , Dismantling Works : Charges For Dismantling The Existing Electrical Installations Complete Making Good The Damages Of The Wall And Conveying The Dismantled Materials To Store Etc As Required. , Cctv & Public Addressing System: Supply, Installation, Testing And Commissioning Of Ip Based 3.6 Mm Fixed Lens, 2Mp Resolution, H.264 / H.265, 1/2.8 Progressive Scan Cmos Day/Night, Ir Dome Poe Enabled Camera,20 To 30 Meters Ir Range, 120 Db Digital Wdr With All Connectors And Necessary Accessories For Mounting In False Ceiling As Required For Complete Installation As Directed By Engineer In Charge. , Ceiling Mounted Speaker - Supply, Fixing, Testing And Commissioning Of Ceiling Mount Metal Grille Speakers With Inbuilt Line Matching Transformer With Power 6W With All Accessories Required For Complete Instllation As Required. , Wall Mounted Speaker - Supply, Fixing, Testing And Commissioning Of Wall Mounted Speakers With Inbuilt Line Matching Transformer With Power 9Wwith A Volume Controller To Adjust The Volume Individually As Per The Requirement With All Accessories Including Wall Mounting Kit Required For Complete Instllation. The Volume Controller Shall Be Fixed Separately As Per The Site Condition For Individual Control. Cost Inclusive Of Necessary Interconnection Including Conduit, Connection Wire Etc , Mechanical Ventillation System: Axial Fans: Supply, Installation, Testing And Commissioning Direct Driven Axial Flow Fans Suitable Formountingonwallorductinstandardgalvanized/Powdercoatedsteelconstructionwith Requiredrating,Static,Singlemotorandflexibleconnectiontoconnectwithducting/Plenum, Louvers With Birdscreen. The Cost Inclusive Of Ducts Required As Per The Layout. 50 - 250 Cfm , Supply, Installation, Testing And Commissioning (Sitc) Of 8.75 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu/Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring(Max 3M From Isolator) And Control Cabling(Indoor To Outdoor),Thermostat Wiring, High-Low Pressure Cut Out,Suitable For Three Phase 440V Supply Etc Complete As Required (Not Taken For Evaluation) , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalised, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Busbars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb (0-500)V Class 1 With 90 Deg Defl. Scale. (0-200)A Class 1 With 90 Deg Defl. Scale Voltmeter Selector Switch 200/5 A 5 Va Class .5S Cts On/Off Indication Lamp Digital Multifunction Meter To Read V,A.Hz,Pf,Kwh Surge Protection Device (Type1+2) Incomer 400A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 200A Copper Tpn Busbar Chamber With Copper Busbar Out Goings 250A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 160A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 100 A Fp Mccb Isolator-2Nos 63 A Fp Mccb Isolator-2Nos The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification (Not Taken For Evaluation) , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. 4A Sp Mcb (0-500)V Class 1 With 90 Deg Defl. Scale. (0-200)A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200/5 A 5 Va Class .5S Cts On/Off Indication Lamp, Digital Multi-Function Meter To Read V,A.Hz,Pf,Kwh Incomer 250A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 250A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 200 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos. 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 2 Nos. 63 A Fp Molded Case Circuit Breaker - 2 Nos.The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification (Not Taken For Evaluation)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
16.
Drinking Water Supply and Sanitation #10279059 Price Bid
Tender For Rehabilitation Improvement And Basic Facility Of Parbati Dam District Dholpur. - 5.1.2Excavation including loading, unloading, disposal and dressing of excavated earth within initial lead of 50m and lift up to 1.5m including dressing of excavated area and dewatering wherever required complete in all respect Hard / dense soil 2 Dismantling doors, windows and clear story windows (steel or wood) shutters including chowhats, architrave and holdfastsetc. Complete and stacking 50 m lead of area 3 square meter and below 3 Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required. From 5 to 10 m depth 4 Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size.Welded mesh 50 x 50mm x 16 gauge 5 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Providing & Fixing of of Double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . WITH 225 mm sweep 7 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011. withStainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/work , refer Annexure A attached with this BSR . 0.5 HP, 1-Ø, (3 - 18)Mtr, (100-26) LPM 8 Supply , Installation, Testing and Comissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 1.5 TR ISEER not less then 3.8 9 Random rubble stone masonry (using R. R. stones where 75 % stones to be not less than 15 cm in size in any direction and weighing not less than 23 kg.) for Superstructureincluding curing all leads of all construction materials including curing etc. complete. in cement sand mortar 1:4 10 Add extra over item No. 18 (b) for compaction in restricted area nearby structure or flanks by hand rammers or by pneumatic tampers. 11 Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required. From 10 to 15 m depth 12 Water Bound Macadam (Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density.)By Mechanical Means: Grading- I (Using Screening Crushable type such as Moorum or Gravel)Using Screening Crushable type such as Moorum or Gravel 13 11.5.4Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required. From 15 to 20 m depth 14 Prime coat (Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.60kg/sqm using mechanical means 15 Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required. From 20 to 25 m depth 16 Tack coat Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous/granular surface cleaned with mechanical broom 17 Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required. Beyond 25 m depth 18 Open - Graded Premix Surfacing (Providing, laying and rolling of open - graded premix surfacing of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or cut-back or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a smooth wheeled roller 8- 10 tonne capacity, finished to required level and grades.)(I)a Case - I: Mechanical method using Penetration grade Bitumen and HMP of appropriate capacity not less than 75 tonnes/hour .Using VG-30 binder 19 Drilling more than 48 mm but upto 76 mm dia, holes in all types of rock or artificial hard material like concrete or masonry for consolidation/ curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required.Up to 5 m. depth 20 Providing and laying premix seal coat using hot mix plant and paver finisher with aggregates of 6.7mm size defined as 100% passing through 11.20mm sieve and retained on 2.36mm sieve with 0.09 cum per 10 Sqm and 4.5%bitumen including preparation and transportation of mix, spreading, laying and rolling etc. complete in all respect including cost of binder.(ii) Bitumen grade VG30 @ 4.50% 21 Drilling more than 48 mm but upto 76 mm dia, holes in all types of rock or artificial hard material like concrete or masonry for consolidation/ curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required.From 5 to 10 m depth 22 dismantling roofs with care including stacking of serviceable material and disposal of unservicable material within 50m lead for lime terrace 23 Supplying and lowering into holes and fixing of casing pipes of suitable diameter to enable drilling of minimum 48 mm dia grout holes. 24 dismantling stone slab roofing over wooden karries or RCC battens ( dismantling karries and battens to be paid for separately) including stacking of servicable material and disposal of unservicable material within 50 m lead 25 11.7Washing and open flushing of drilled holes by alternate jet of air and water under pressure prior to pressure washing and flushing or grout after stage grouting including cost ofequipment, compressed air and etc. complete. 26 Dismanling old plaster or skirting , raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 m lead 27 11.8Normal pressure washing of drilled hole in stages in approved pattern for cleaning of clay, soil and other filler materials from the seams and joints in the foundation rock by establishing connections under pressure with air & water including cost of equipment, accessories compressed air, water, labour, admixtures if any required etc. complete as per specification. 28 Dismantling flooring with care including stacking of servicable material and disposal of unservicable material within 50 m lead for: cement concrete flooring 29 5.16.1Earth work in rough (borrow area) excavation for embankments in hard soil, morrum or highly weathered strata dry or moist, including laying in 20 cm layers (before compaction) and breaking of clods, sorting of grass, pebbles etc. and dressing when compacted by vibro compactor, vibro sheep foot roller, sheep foot roller/pneumatic tyred roller to obtain dry density of at least 98% of Standard Proctor s density with initial lift of 1.5m (Excluding charges for compaction and watering) including loading and un-loading wherever required complete in all respect.With initial lead of 250 m 30 Supply and fixing of steel doors, with frame of hollow metal pressed section 105×60 mm as per I.S.I 1.25mm thick with double sheet shutter 1.00 mm thick M.S. sheet tospot welded and embossed with rib type design on both sides, front side vertical and back side horizontal and spot welded including hold fasts of (15×3mm), M.S. oxidized fittings such as butt hinges sliding door bolts, handles, tower bolts etc. complete in all respect as per drawing and specifications including applying priming coat of approvedsteel primer 31 11.10Conducting water intake test in test holes under pressure for determining permeability before or after grouting including cost of equipment and water etc. complete 32 Earth work in excavation in foundation trenches or drains including dressing of sides & ramming of bottoms , lift up to 1.5 m including taking out the excavated soil & depositing & refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed within lead of 50 m : all kind of soils 33 11.9Grouting of drilled holes minimum 35 mm dia with or without packers with cement/ clay and or chemicals (in the form of slurry with water) in prescribed ratio till refusal including cost of grouting equipment, compressed air and water etc. complete but excluding cost of cement, clay and chemicals (only dry weight of ingredients excluding chemicals to be considered ) with a working pressure upto 15 kg/Cm2 (Dry cement consumption) 34 Providing and laying in position cement concrete including curing, compaction etc.complete in specified grade excluding the cost of centering and shuttering - all work up to plinth level: M10 grade nominal mix (with graded stone aggregate 20mm nominal size (P.C.C. in foundation) 35 16.33Exploratory vertical drilling of bore holes 150 mm dia through all kind of soils with the adequate / suitable equipments, tools and tackles for depths mesured below existing ground level including mobilization, setting up boring rig, shifting of rig from 1 bore hole to another and demobilization of the same 36 Random Rubble Stone masonry for superstructure above plinth level one storey height above 30 cm thick walls in: cement sand mortar 1:6 37 16.32.3Boring NX dia (54.7 mm dia), hole with diamond coring bits including taking out of core and arranging etc. core in proper order in core boxes including cost of core boxes. as per relevant I.S. code of practice. These rates are including Mobilization & demobilization of Rig. In sand stone and harder variety of lime stone 38 Filling available excavated earth ( excluding rock) in trenches ,plinth side of foundation etc. in layer not exceeding 20 cm. in depth , consolidating each deposited layer by ramming amd watering including lead up to 50 m and with all lift 39 5.1.3Excavation including loading, unloading, disposal and dressing of excavated earth within initial lead of 50m and lift up to 1.5m including dressing of excavated area and dewatering wherever required complete in all respect Hard soil mixed with Kankar / boulders, Morrum 40 Brick masonry in foundation and plinth with bricks of class designation 75 in: cement mortar (1:6) (1 cement : 6 coarse sand) , add extra for superstructure upto third storey 41 10.1.1Side shuttering including propping etc. complete (to achieve finish F 2 for :Block joints of foundation stilling basins buckets, aprons etc. (non -suspended horizontally laid massconcrete) 42 Providing and laying in position specified grade of cement concrete for RCC structural element upto floor three level including curing , compaction, finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of shuttering , centering and reinforcement for: Beams, suspended floors, roofs, girders having slopes up to 15degree, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircase and spiral staircases : M20 grade nominal mix/design mix Desc/Location Nos L B H 43 9.8.3Providing and Laying in position of Cement concrete Nominal mix (1:3:6) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto 40 mm 44 centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation in basements rafts, footings, straps beams, bases of column etc up to plinth level 45 9.6.4Providing and Laying in position of Cement concrete Nominal mix (1:1.5:3) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto; 20 mm 46 P/F steel reinforcement for RCC work including cutting bending placing in position and binding complete including cost of binding wire in foundation raft footing step beams base of columns etc. upto floor three level .: Hot rolled deformed bar (IS : 1139) 47 7.1.2Random rubble stone masonry (using R. R. stones where 75 % stones to be not less than 15 cm in size in any direction and weighing not less than 23 kg.) for foundation including curing with all leads of all construction materials including curing etc. complete. In cement sand mortar 1:4 48 PLASTER (Ceiling) 6 mm thick. Cement plaster to ceiling of mix 1:3 (1 cement : 3 fine sand) 49 8.13.2Flush or ruled pointing on stone masonry including racking of joints and curing etc. complete including all leads of all construction materials in mortar ratio. In Cement sandmortar 1:4 50 PLASTER (Internal) Plaster on new surface on wall in cement sand mortar 1:6 including ranking of joints etc. complete fine finished 20 mm thick. 51 5.9.1Extra charges for disposal of excavated/re-handled material in required profile laid in uniform layers and given side slopes well dressed having layer thickness including loading and un-loading wherever required with cost of dewatering wherever required complete in all respectNot exceeding 15cm 52 Painting with enamel paint of approvd brand and manufacture to give an even shade : Two or more coats on new work 53 18.17.2Providing and laying cement concrete coping in (1:2:4) with maximum size of crusher broken aggregate upto 20 mm including shuttering etc. with all leads of material complete in all respect in thickness of: 50 mm 54 Granding for roof water profing treatment with cement motor 1:4 (1 cement : 4 coarse sand) 2 inch thick 55 18.28.1.2Providing, laying and fixing in position RCC spun or hume pipe with collars (ISI 458- 2003) in required size packed in gasket for hume or spun yarn & neatly finished with rich grout of cement mortar 1:3 perfectly air tight including testing of joints. 150mm NP3 56 Polished Blue kota stone flooring Skerting, Laid over 20 mm thick base of cement mortar 1:4 and jointed with Grey cement Slurry to match of the Shade of the Slab including rubbing and polishing complete for area of each slab from 2001 to 5000 sq. cm. 25 mm thick slab 57 11.19Reaming, redrilling and pressure jet flushing of foundation holes of NX size, in the drainage gallery of dam, using diamond drill bit of suitable size, diamond reamer shell with using hydraulically operated rotary core drilling equipments, rods of suitable length to specified depth, fixing PVC pipes with caps, including cost of materials, hire charges of equipments, fuel, labour with all leads and lift etc. complete as directed by Engineer in Charge 58 Providing brick kharanja in cement sand mortar 1:4 in square pattren over roof of ground floor (75 mm to 100 mm thick avarage) Add for if cement mortar 1 : 4 is used instead of lime sand mortar 1 : 2. 59 18.50Cleaning drainage gallery, adits, instrumentation galleries etc. by scrubbing/ brushing including chiseling and removing leached lime deposit and disposing off all the waste materialoutside adits in specified location as directed etc., complete with all leads and lifts. 60 Plaster on new surface on walls in cement sand mortar 1:4 including raking of joints etc. complete fine finish 20 mm thick Add extra over item No. 12.7 to 12.10 for water proofing compound if used @ 2% of the cement by weight. 61 9.8.4Providing and Laying in position of Cement concrete Nominal mix (1:3:6) including leads of all construction materials, curing, compaction and finishing with rendering in cement sandmortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto 20 mm 62 Stone slab roofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both sides in cement sand mortar 1:4 ralthal, stone kharanja, lime terracing 90 mm avarage thickness [as per JAIPUR PRACTICE] with ceiling pointing in cement sand mortar 1:3 per specification for span:above 3.00 metre and upto 3.30 metre. 63 10.1.3Side shuttering including propping etc. complete (to achieve finish F 2 for :Retaining wall, counterfort, abutment, wing walls up stream or down- stream slope facings of dams and open faces of construction joints etc. 64 Providing and fixing T-iron frame for doors windwos and ventilators of mild steel tee-setions, joints mitred and welded with 15x3 mm lugs embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 200 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butts hinges and screws and applying a priming coat of approved quality 65 10.9.2.2Supplying of M.S. reionforcement including labour charges for bending binding and placing in position all reinforcement as per drawing including cost of binding wire and all leadsand lifts using. Tor or ribbed bars (IS :1786-1985) 66 window:Providing and fixing Ms sheet double leaf doors shutter in angle iron frame 35x35x5 mm suitabilly digonally braced with 25x3 mm flat iron above and below lock rail of size 50x5 mm beading extra including all fittings, as per direction of engineer incharge. M.S. Sheet 20 SWG 67 10.9.1Labour charges for steel reinforcement including bending, binding, and placing in position all reinforcement as per drawing including cost of binding wire and all leads and lifts. 68 Doors:-Providing and fixing M.S. sheet 1 mm thick double leaf door shutter in angle iron frame 35x35x5 mm siutabilly diagonally braced with 25x3 mm flat iron above and below lock rail of size 50x5 mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chokhats: including two coats of anit-corrosive red oxide primer paint. M.S. Sheet 22 SWG 69 10.10.2Extra labour charges for RCC due to obstruction in laying and placing the reinforced cement concrete due to reinforcement. Columns, slabs, cantilevers projections staircases, lintels, beams, chajjas, Retaining walls, piers, abutments, galleries, arch covers, bed plates, sluice capstan bases etc. 70 Supplying & fixing fixed wire Gauge of 14 mesh X 24 Gauge to the Metal frame of rolled section by metal beading 20X3 with suitable screw at not exceeding 150 mm distance 71 5.8.1Re-handling of excavated material including loading unloading and dressing within initial lead of 50 m and lift of 1.5m with cost of de-watering wherever required and all applicabletaxes and levies etc. complete in all respect Earth / Soil 72 Providing and fixing square bars or other flat welded to window ventilators etc. 10mm x 10mm 73 5.18.2.2(ii)Compaction of earth or highly weathered strataBy mechanical equipment such as sheep foot roller/ pneumatic tyred roller/vibro compactor / vibro sheep foot compactor required as per site condition to obtain dry density of. at least 98% of Standard Proctor s density 74 Polished blue kota stone flooring skirting laid over 20mm thick base of C.M. 1:4 and jointd with grey cement slurry to match the shade of the slab including rubbing & polishing complete: for area of each slab from 901 to 2000 sqcm (a) 25mm thick slab 75 5.9.2Extra charges for disposal of excavated/re-handled material in required profile laid in uniform layers and given side slopes well dressed having layer thickness including loading and un-loading wherever required with cost of dewatering wherever required complete in all respect Not exceeding 20cm 76 Providing & fixing steel gate grating and grills made of angles, tees, square bars or other flats black pipe with holdfast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. 77 5.10.1Beyond initial lead of 50 m & upto 250 m 78 Finishing wall with water proofing cement paint of approved brand & manufracture and of required shade to give an even shade including all scafolding new work (three or more coats) 79 5.30Supplying and laying sand of grade as per design requirement in required profile including all lead & lifts.This item is to be used only for laying filter / inverted filter 80 White washing with lime to give in even shade including all scaffolding on new work (three or more coats). 81 5.31.2Supplying and laying aggregate in layers and profile as specified including all leads & lifts.This item is to be used only for laying filter / inverted filterBroken ballast 20 to 40 mm size 82 P & F rigid PVC pipe (IS 4985 Mark) Class 2nd / (4 kg / sqcm) approved quality / Make including jointing the pipe with solvant cement rubber ring and lubricant 110 mm dia. 83 11.14Prepration of old masonry surfaces before laying of further masonry or concrete over it by cleaning the surface and mortar joints with brushing and raking finally, washing by compressed air & water under pressure 84 PVC bend 110 mm 85 37 mm thick shotcrete by wet mix process, applied with compressed air gun after chipping of defective concrete / masonry, racking the joints, cleaning of surface thoroughly with wet sand blasting after fixing of 9 gauge good quality rust free welded mesh of size 50 mm x 50 mm in TWO layers with anchors / clamps. After racking the joints clean the surface thoroughy by wet sand blasting, anchor the first layer of welded mesh in position and apply 15 mm cement concrete (1:2:1) by pressure gun and after hardening of first layer, anchor second layer of welded wire mesh, apply 22 mm thick cement concrete complete in all respect. Cement concrete comprising of cement, sand, coarse aggregate, water and quick setting compound in the proportion 1:2:1, sand and coarse aggregate conforming to IS 383 and table no. 1 of IS;9012 respectively. 86 Pointing on stone masonry in lime sand mortar 1:2 (1 lime putty : 2 sand) : Raised and cut pointing 87 11.18Add extra over item No. 16 &17 for each subsequent height 3.00 m or part there-of above initial lift of 5 m from ground level (upward or downward) 88 P & F unplasticized poly choride (UPVC) SWR pipe fitting type B for sciland waste discharge system ( IS : 13592: 1992 marked) of approved quality / make 110mm dia 89 12.30.3Providing Rubber seals as per IS:11855 for Dam sluice, canal, barrage, stop dam etc. gates of required size and type and specifications with testing, including all lead and lifts, packing & forwarding charges for all components etc. complete. Rubber seal musical note type 100mmx44mm x14mm (44mm Bulb) Tefloncladded 90 P&F Indian type white glazed vitreous china Ist quality W.C. orissa pan (IS : 2556 mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor : size530x410 mm 91 12.40Labour charges for removal of existing wornout/damaged bottom and side rubber seal of Stop Log Gate of Dam by cutting bolts with gas cutter, providing holes in new rubber sealinsertion of sleevs and fixing over gates with nut blots, washer ect including cost of gas (LPG and Oxygen) cylinder etc complete 92 P & F WVC wash basin (Ist quality, I.S. : 2556 mark) of approved make with C.I. brackets duly painted, 1 No. 15 mm C.P. pillar cock (IS : 8934 mark) & 32 mm C.P. brass waste coupling of approved make. 25 mm G.I. waste pipe complete including cutting & making good the wall : Size 450 mm x 300 mm 93 12.38Labour charges for removal of existing wornout/damaged bottom rubber seal of crest Radial Gates, Vertical Gates and Intake Service Well Gates of Dam by cutting bolts with gas cutter, providing holes in new rubber seal insertion of sleevs and fixing over gates with nut blots, washer ect including cost of gas (LPG and Oxygen) cylinder etc complete. 94 P & F G.I pipes (internal work) with G.I. fittings (IS:1239 mark) & MS clamps including cutting and making good the walls and floors : Exposed on wall A (i) 15 mm dia nominal bore 95 5.28.1Watering of earth including cost of carriage of water when source of water is up to 1 Km 96 Painting with enamel paint of approvd brand and manufacture to give an even shade : One or more coats on old work 97 12.39Labour charges for removal of existing wornout/damaged side rubber seal of crest Radial Gates, Vertical Gates and Intake Service Well Gates of Dam by cutting bolts with gas cutter,providing holes in new rubber seal insertion of sleevs and fixing over gates with nut blots, washer ect including cost of gas (LPG and Oxygen) cylinder etc complete 98 P & F PVC storage tank (IS : 12701 marked indicating the BIS license No), of approved make with cover, 25 mm dia 1M long G.I. over flow pipe & 25 cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design : 300 litre capacity. 99 12.31.2Painting of Spillway gates, sluice gates, canal gates (both vertical or radial),stop log gates, exposed embedded parts and all un machined ferrous surface (hoist cylinders, cylinder heads, hydraulic piping, pipe fittings, bonnet covers), exposed to water as per IS 14177,for which surface preparation by blast cleaning of class B primer coat (one coat) of inorganic zinc silicate (preferably airless spray)or alternatively, two coats of zinc rich rimer(containing not less than 85% zinc on dry film) to give dry film thickness of 70 5 micron and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 150 5 micron per coats. Thus, total dry film thickness of all the coats, including primer coating, should not be less than 350 microns, this will be include expenses on mobilisation and demobilisation of equipments. For maintenance painting the surface preparation shall be done by appropriate hand and power tool cleaning, prior to hand power tool cleaning. Any heavy layer of rust should be removed by chipping visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylol or white gasoline. After hand and power tool cleaning the surface should be cleaned of loose dust and debris and/or blast cleaned as laid down in para 7.0 of IS code 14177. After the surface preparation the primer and finishing coats shall be carried out as provided above for painting etc. complete.Beyond 1.5m height 100 P & F stop cock (IS : 8931 mark), superior quality & of approved make : brass 400 gm. 15 mm nominal bore 101 12.31.2Painting of Spillway gates, sluice gates, canal gates (both vertical or radial),stop log gates, exposed embedded parts and all un machined ferrous surface (hoist cylinders, cylinder heads, hydraulic piping, pipe fittings, bonnet covers), exposed to water as per IS 14177,for which surface preparation by blast cleaning of class B primer coat (one coat) of inorganic zinc silicate (preferably airless spray)or alternatively, two coats of zinc rich rimer(containing not less than 85% zinc on dry film) to give dry film thickness of 70 5 micron and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 150 5 micron per coats. Thus, total dry film thickness of all the coats, including primer coating, should not be less than 350 microns, this will be include expenses on mobilisation and demobilisation of equipments. For maintenance painting the surface preparation shall be done by appropriate hand and power tool cleaning, prior to hand power tool cleaning. Any heavy layer of rust should be removed by chipping visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylol or white gasoline. After hand and power tool cleaning the surface should be cleaned of loose dust and debris and/or blast cleaned as laid down in para 7.0 of IS code 14177. After the surface preparation the primer and finishing coats shall be carried out as provided above for painting etc. complete.upto1.5m height 102 P & F looking mirrors with P.V.C. frame of approved (Atul, Modi Guard , Saint Gobin or equivalent) size 500 x 400 mm 103 18.13Painting distance mark stone and lettering with light blue white or yellow un-washable paint including cost of material 104 P & F flush cock/flush valve (IS 9758 mark) for WC of approved quality make : CP brass half-turn exposed 25 mm nominal bore. 105 12.37Oiling and greasing of Crest radial gates,Vertical Gates and Intake Service well Gates of Dam including all charges of man and material complete, which include cleaning of wire rope with petrol / diesel and applying Cardium compound to wire ropes, oiling & greasing etc complete as per direction of Engineer-in-Charge 106 Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20 mm thick insider plaster in cm 1:6 , finished with floating neat cement, 50 mm thick M-15 grade C.C. flooring, earth work etc. complete as per design including disposal of surplus earth with in a lead of 50 mtr. inside size 300 x 300 mm depth up to 0.5 m cement cover with frame. 107 12.4Design, Drawing, fabrication, supply, erection, testing and commissioning of Vertical lift sliding type gate with frame consisting of skin plate, sealing frame, stiffeners, horizontal and vertical girders, guide, stainless steel flat/Brass flat, rivets,wedges, lifting rods etc., with all accessories as per relevant IS code including frame & gate complete set for Canal Cross, Escape, Head regulator /Tank head regulator includingcost of all materials, machinery, labour, cutting, aligning, welding, finishing, cleaning, seal fixing, tools and tackles etc., applying two coat of zinc rich epoxy primer to give dry film thickness of 70 5 microns and finish coat (two coats) of solvent less coal tarepoxy paint using airless spray to provide dry film thickness of 150 5 microns per coat thus total dry film thickness of all coats, including primer coating, should not be less than 350 microns., complete as per specifications and approved drawings with all lead and lifts, including packing & forwarding, transportation charges for structural steel components and other materials. 108 Construction of soakage well in all types of soil of approved drawing, top 90 cm. Portion in 450 mm thick masonry with cm 1:6, 80 mm thick stone slab covering, jointing of slab in cm 1:3, Ralthal, Kharanja 40 mm thick M-15 grade C.C. flooring, earth work etc. complete including disposal of surplus earth with in a lead of 50 mtr. inner dia 90 cm & 10 to 12 mtr deep 109 11.13Preparation of surface of existing concrete surface/ masonry in lime mortar/ cement mortar including removal of organic deposit by washing with etching compound and use of wet sand blasting and final washing the surface with air and water jet including cost of all material and equipment required for the work complete. 110 Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm comfirming to IS : 13753 colour such as white, grey, ivory, fume red brown, light green, light blue and other lightshades in floors, steps, pillars etc. laid on a bed of neat cement slurry including nicely finished joints using water proof joint filler powder (Untile or Roffe make) and finishing with flushpointing in white cement mixed with pigment to match the shade of tile complete (including the cost of cement mortar bed 1:4) Category-A : Kajaria, Jhonson, Somani make 111 12.52.1.11Providind of Rubber Seals as per IS 11855 for dams, sliuce, canals, barrage ,stop log gates etc of required size and type and specifications with testing , including all lead andlifts, packing and forwording charges for all components etc. complete in all respectRubber Seal Musical Knot, Solid Bulb type of Size 75mm 35mm x 10 mm 112 Add extra over item No 7.6.1 and 7.6.2 for using 400x400mm size MAT finished tiles inplace of 300x300mm size 113 12.52.1.9Providind of Rubber Seals as per IS 11855 for dams, sliuce, canals, barrage ,stop log gates etc of required size and type and specifications with testing , including all lead andlifts, packing and forwording charges for all components etc. complete in all respectRubber Seal Musical Knot, Solid Bulb with brass clading type of Size 100mm 45mm x 15 mm 114 Providing & fixing steel glazed doors, windows and ventilators with shutters of standred rolled steel section joint mitred and welded with steel 13x3mm lugs 10 Cm. long embedded in cement concrete blocks 15x10x10 Cm. of 1:2:4 (1-Cement:2-coarse sand:4-graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws orwith fixing clips or with bolts and nuts as required, including providing and fixing of plain glass panes 4mm thick with copper glazing clips and special metal-sash putty of approved make, or metal beading with screws complete including priming coat of approved steel primer, excluding the cost of metal beading and other fittings except necessary hinges of pivots steel handles and peg stay etc. as required. doors 115 12.49.2Oiling, Greasing work of gate parts like Headstock, Headstock parts, Roller Assembly, Operating Rod, Sealing Frame, Guide Tee with all Labor tools and tackles etc. and Materialfor vertical lift sliding type/ fix wheel gates excluding cardium compund and gear oil For gate size above 1 Sqm to 10 Sqm 116 Providing & fixing steel glazed doors, windows and ventilators with shutters of standred rolled steel section joint mitred and welded with steel 13x3mm lugs 10 Cm. long embedded incement concrete blocks 15x10x10 Cm. of 1:2:4 (1-Cement:2-coarse sand:4-graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws orwith fixing clips or with bolts and nuts as required, including providing and fixing of plain glass panes 4mm thick with copper glazing clips and special metal-sash putty of approved make, ormetal beading with screws complete including priming coat of approved steel primer, excluding the cost of metal beading and other fittings except necessary hinges of pivots steelhandles and peg stay etc. as required.windows sidehung(openable) 117 5.33Supplying and laying quarry spalls properly graded but not more than 10cm in size with spreading in required profile including all leads & lifts 118 Distempering with oil bound washable distemperr of approved brand and manufacture to give an even shade including all scaffolding : old work (one oe more coats) including scrapping surface and necessary repairs (a) colour change 119 12.36Operation of vertical / radial gates, hoist operation, stop log gates, Gantry Crane, mono rail etc. at Dams for all seasons round the clock whenever required, as per direction of Engineer in-Charge, by providing sk illed & semi skilled staff well conversant with the work of operation of gates as well as meet out all types maintenance & repair work of gates whenever required in any emergency during operation of the gates including deployment of Chowkidar at gate section of the Dam 120 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding : New work (two or more coats) over and includingscrapping and priming coat with cement primer 121 5.2.2Excavation including loading unloading disposal and dressing of excavated rock within initial lead of 50m and lift upto 1.5m in dry or moist including dressing of excavated area, dewatering wherever required complete in all respect.Hard rock not requiring blasting 122 P & F bib cock (IS : 8931 mark), superior quality of approved make : Brass 400 grm, 15 mm nominal bore 123 18.1.2Cutting & clearance of jungle, bushes, shrubs Ankra/Ipomoea, Juliflora typna etc. on canal and bunds in dry/moist/slushy conditions including disposal as per instructions of the Engineer-in-charge. Cost of wood has been deducted from rates and thus will be property of contractor after cutting. Thick 124 P&F sand cast iron (S.C.I.) Pipe (IS:1729 mark) of approved make in wall in floor with MS holder bat clamps in 10X10X10 cm. M15 grade concrete block joints filled with CM 1:4 with spun yard including cutting holes and making good the wall.150mm dia. 125 17.5.2Demolishing stone rubble masonry including stacking of usable material and disposal of unuseable material within 50 meters lead inclusive of de-watering wherever required.In cement mortar 126 P&F SCI fittings (IS1729mark) in CM 1:4 spun yarn150mm w/o door Bend 127 5.2.3Excavation including loading unloading disposal and dressing of excavated rock within initial lead of 50m and lift upto 1.5m in dry or moist including dressing of excavated area, dewatering wherever required complete in all respect.Phylite & other hard rock requiring nominal blasting 128 spray painting with flat wall paint of approved brand and manufacture to give an even shade : two oe more coats on new work including priming coat of distemper primer of approved brandand manufacture 129 11.2.1Drilling 35 mm.to 48 mm. Dia holes in all types of rock or artificial hard material like concrete or masonary for consolidation/ curtain grouting in stages by percussion drillingincluding cost of drilling equipment, compressed air, water etc. complete & re-drilling in the hole through set grout, if required.Up to 5 m. depth 130 S&F following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according to IS Specified along with ISI marked (IS:14768 P-II 2003) accessories in recessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required including cutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR. dia 50mm 131 11.2.2Drilling 35 mm.to 48 mm. Dia holes in all types of rock or artificial hard material like concrete or masonary for consolidation/ curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete & re-drilling in the hole through set grout, if required.From 5 to 10 m depth 132 S&Providing & Fixing of ISO certified company made off load change over switch four pole/two pole, 230/ 415 V ,side handle operated conforming to IS:13947 P-III in sheet steelenclosure complete with connections with lugs, testing etc. as required in the following rating: All as per pre approved by Engineer in charge. For additional technical parameters ofproducts/ work , refer Annexure A attached with this BSR . 32 A, Four poleF following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according toIS Specified along with ISI marked (IS:14768 P-II 2003) accessories in recessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required including cutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR. dia 50mm 133 2.9.2Cement OPC (in bags) 50 Kg in weight. As per IS 1489 and IS 8112 (excluding cost ofempty begs). 134 S&PP & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nutand bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSRroviding & Fixing of ISO certified company made off load change overswitch four pole/two pole, 230/ 415 V ,side handle operated conforming to IS:13947 P-III in sheet steel enclosure complete with connections with lugs, testing etc. as required in thefollowing rating: All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 32 A, Four poleFfollowing sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according to IS Specified along with ISI marked (IS:14768 P-II 2003) accessories in recessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required including cutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR. dia 50mm 6.4 mmthick 135 10.2Centering and shuttering for slabs, beams, lintels Columns, trough with or without caps and base including propping and remove 136 P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/frames including making holes for switches etc, with brass screws, washers/ zinc plated nut and bolts as required. For additional technical parameters of product / work refer Annexure Aattached with this BSR 9 mm thick 137 11.1.1.1Drilling holes of 35 mm diameter for anchor rods.Upto 1.50 m. depth 138 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity(B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulsewithstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimumphase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including makingconnections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. Foradditional technical parameters of product / work refer Annexure A attached with this BSR (a) 6 Amp to 32 Amp rating 139 5.35.3Supplying stone, spall and laying R. R. stone pitching, hammer dressed with packing ofvoids from small stones including all lead & lifts, in required profile of 23 cm thickness ( 5 % thickness tolerance) 140 Providing corrugated G.I. Sheet roofing fixed with G.I.J. or L hooks bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coat of approved paint on over lapping of sheet complete (upto a pitch of 60o) & excluding the cost of purlins rafters and truses, for class of sheets :1.60mm thick 141 11.1.2Labour charges for Fixing of anchor bars in neat cement grout including cost of cement and curing etc. complete 142 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contactprotection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDAaccrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Triple pole MCB 50/63 A rating 143 11.1.3Supply of Tor steel anchor bars of required diameter, length and shape at site of work complete. 144 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contactprotection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR (c) Double pole MCBS of 50 AMP to 63 AMP 145 12.7Design, Drawing, fabrication, supply, erection, testing and commissioning of Adequate capacity manually operated rope drum hoist according to relevant IS code, consisting ofhoist platform bridge, rope drums, connecting shaft, gear system unit, pulleys, wire rope, Gate position indicator, manual operation system, etc. complete, with all accessories for operating gates including cost of all materials, machinery, labour, cutting, aligning, anchoring, welding, finishing, cleaning, greasing, oil filling, tools and tackles, applying two coats of zinc chromate red oxide primer and three coats of approved synthetic enamel paint etc., complete as per specifications and approved drawings, including packing & forwarding, transportation charges for all materials. 146 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door (Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel /CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including makingconnections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 4 way Metal door (single phase) 147 12.1.1Design, drawing, fabrication, supply, erection, testing and commissioning of Embedded parts consisting of sill beams, vertical tracks, vertical seal tracks, sealing frame, guide tracks/rails, wall plates, seal seats, anchors, anchor girders, yoke girders, tie flats, trunnion supports, rope and pulley supports etc. and any required necessary item, with all accessories as per relevant IS code, for all type radial gates/ Vertical lift fix wheel type sluice and Canal gates/Stop log gates including cost of all materials, machinery, labour, cutting,aligning, anchoring, welding, finishing, cleaning, tools and tackles, applying two coat of zinc rich epoxy primer to give dry film thickness of 70 5 microns and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thicknessof 150 5 microns per coat thus total dry film thickness of all coats, including primer coating, should not be less than 350 microns., including packing & forwarding, transportation charges complete item, as per specifications and approved drawings 148 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door (metal / Glazed )Distributio board with Metal end box made out from Galvanized steel /CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. Foradditional technical parameters of product / work refer Annexure A attached with this BSR 12 way Metal door (single phase) 149 18.49Under water videography of dam body & its appertunance i.e gates, under sluice, emergency gate grooves clearly showing location defect area or area of interest indicatingcondition from all possible angles and special focus on damaged portions complete in all respects upto the satisfaction of Engineer in charge. The work also includes supply of three sets of video in digital form and a depth wise report prepared in hard copy 150 Providing & fixing in position frame made out of MS angle (riveted or welded) finished with two coat of red oxide and enamel paint of following size as required 38*38*6 mm 151 12.8.1Design, Drawing, fabrication, supply, erection, testing and commissioning of Adequate capacity manually operated screw type hoist according to relevant IS code, consisting of supporting structure, platform bridge etc., operating handle, gate positionindicator, plumber block, couplings with all required accessories for operating Head/cross/escape regulator gate including cost of all materials, machinery, labour, tools and tackeles, cutting, aligning, anchoring, welding, finishing, cleaning, greasing, oiling, applying two coats of zinc chromate red oxide primer and three coats of approved synthetic enamel paint etc., complete as per specifications and approved drawings with all lead and lifts,including packing & forwarding, transportation charges for structural steel components and other materials. 152 Providing & Fixing of energy efficient direct fit (Retrofit) Polycarbonate/ Glass housing SMD Mid Power LED tube rod (with integral driver & alumn. heat sink ), on existing fixture. systemlumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0. 95,CRI >80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintanedtill life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall besubmitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .600mm , Min. Lumens output 1800 lm LED Tube rod with Polycarbonate Housing 153 5.15.1.1Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. In all typessoils/ saturated soil such as morrum, sand, sandy silt, clay, black cotton soil, kankar, etc. Depth upto 1.5 m 154 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protection with ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA, provision for pad lock, min. Electrical operation 10,000 upto 63 A rating ,minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Four pole 100/300 mA sensitivity 40 A rating 155 7.1.3Random rubble stone masonry (using R. R. stones where 75 % stones to be not less than 15 cm in size in any direction and weighing not less than 23 kg.) for foundation includingcuring with all leads of all construction materials including curing etc. complete. In cement sand mortar 1:5 156 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulationPVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connectionswith Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parametersof product / work refer Annexure A attached with this BSR 1 *2.5 sq.mm 157 9.3.1Providing and Laying in position of Cement concrete Design mix M-25 including leads of all construction materials, plasticizers (if required), curing, compaction and finishing withrendering in cement sand mortar 1:3 ( 1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher brokenstone aggregate of maximum size upto;(For mix design Cement content considered 420 kg/ cum of concrete) 150 mm 158 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connectionswith Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own inhouse NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 1*6.00 sq.mm 159 7.10.2Brick masonry (using well burnt clay bricks of size 230 x 110 x 70 mm, class designation 75 as per specification) up to plinth including all leads of all construction materialsincluding curing etc. complete. In cement sand mortar 1:4 160 Supply and erection of GI stay set confirming to pattern-1 of BS:16/1974 and as per latest Discom Specifications complete with stay rod with anchor plate fitted with cast iron crosshead and steel bow, in cement concrete 1:3:6 including excavation of pit-re-filling etc complete as reqd. All as per pre approved by Engineer in charge.For additional technicalparameters of product / work refer Annexure A attached with this BSR. Stay set of dia 16mm,1.8m long stay rod and anchor plate 300 x 300 x 4.0 mm 161 5.26Threading / turfing of grass on slopes of bunds etc. in rows 15 cm centre to centre in each direction including Ploughing, levelling, breaking of clods, and removal of stones etc. ifrequired including maintenance for 30 days or more till the grass develops fully with all leads and lifts complete 162 Add extra over item No. 10.25 for providing and fixing CGI sheets in curved roofing 163 8.2.1Plaster in cement sand mortar 1:4 including racking of joints, smooth finishing & curing etc. complete including all leads of all construction materials of thickness: 20 mm 164 Supply and fixing of LT porcelain pin insulator as per IS 1445-1997 and as per Discomsstandard specifications,suitable for working voltage 1100 volts including all accessories like MS Forged GI LT Pin confirming to IS:7935/1975 (latest amended) Nut, Bolt etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 100 mm x 70 mm 165 10.1.110.1 Supply, installation, testing and commissioning of MNRE approved Grid tied Solar Panels with inverter, meter, cable etc. suitable for Rooftop installation as well as Utility ScaleSolar Power Projects with 25 years of Linear Generation warranty. Work includes designing of solar panel area and MS frame and foundation on ground/roof of Pump house or CWR,showing arrangement of panel in available space, installation of PV module on MS frame as per approved design and drawings. Mounting structure shall be suitably designed towithstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiency of more than 98%. Connect up to multiple strings PV arrays, Easy & fast connection, Built-in stringlevelmonitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty. All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive.The work shall be executed as per detailed technical specifications, approved drawing and direction of Engineer in Charge Note: There shall be 5 year service warranty for panel, inverter, meter, cable etc. andsuitable provision shall be included in tender document.10.1.1 Solar panels up to 10 KW at a single location. 166 Supplying and drawing overhead steel core Aluminium conductor (ACSR) ISI marked(IS 398 part II-1996) on existing cross arms through insulator with all necessary T&P required including binding and twisting etc. complete in all respect as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure Attached with this BSR 30 Sqmm of (6+1) 2.59mm (Weasel) 167 16.12Hire charges of DGPS instrument with operator and staff for bench mark shifting, topography survey, command area survey, canal survey, dam survey etc. and collection ofdata, plotting the details and preparing digital map of area in layers, and developing contours where ever required as directed by engineer in charge; including supply of detailed drawingsin appropriate scale in soft copy & three sets of Hard copy complete in all respect. These rates are including all types of taxes applicable 168 Providing & Fixing of 6 amp. Combined flush type non modular socket and switch set as per PWD specification for electrical Works,made out from industrial grade Polycarbonate or fireresistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parametersof products/ work , refer Annexure A attached with this BSR 169 16.14.1.3Transfer of Dam / Canal alignment from sajra map to the ground and taking Levels by Auto level or DGPS, develo ping L-section and X-section and submitting in hard copy threesets and soft copy in Auto Cad format, using layer system, showing all features. (Total length of L-section and X-section to be measured for payment) L-section of Dam/ Canal (ii) InPlain area - Levels for L-section to be taken at interval 30 meter. 170 Providing & Fixing of IP 20 box made out from 1.2mm thick CRCA sheet steel with depth of minimun 30 mm and finished with powder coating and suitable for mounting LED tubeincluding side covers, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Suitable for 2 LED Tube shape fixture for single rod 171 16.14.2.3Transfer of Dam / Canal alignment from sajra map to the ground and taking Levels by Auto level or DGPS, developing L-section and X-section and submitting in hard copy threesets and soft copy in Auto Cad format, using layer system, showing all features. (Total length of L-section and X-section to be measured for payment) X-section of Dam/ Canal(Total length of X-section shall be measured) (ii) In Plain area - Levels for X-section be taken at interval 5meter 172 Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. B classwatering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lidsuitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternatelayers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter inmeasurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 173 16.10Grid survey at interval of 30 x 30 meter to conduct submergence survey with TS / DGPSinstrument and prepare 0.50 m interval contour plan and superimposing over khasra map including all ancillary works as described in specifications and conditions of contract. Note: Khasra map will be provided by Department Marking of existing FRL, MWL, MDDL contours and dam alignment. Prepare area-elevation and storage -elevation curves andtables. 174 Providing & Fixing of energy efficient direct fit (Retrofit) Polycarbonate/ Glass housing SMD Mid Power LED tube rod (with integral driver & alumn. heat sink ), on existing fixture. system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0. 95,CRI >80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall besubmitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .1200mm , Min. Lumens output 2000 lm LED Tube rod with Polycarbonate Housing 175 16.6.1Digitization of Jamabandi and providing excel sheet to the department Note: Jamabandi Register will be provided by Department 176 SITC of Radiator Cooled and Turbo charged Silent DG Set (As per latest CPCB emission norms) having specifications as per A, B, C, D, E, F,G,H & I 62.5 KVA at 0.8 pf 415V 50Hz 3-ǿ 177 16.6.2Digitization of Khasra map with details in layers and providing soft copy (acad file) Note: Khasra map will be provided by Department 178 SITC of PLC Based Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stop commands, control Relays , Ammeter& Voltmeter with selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults,UPS, operator interface panel complete in all respect suitable for following capacity DG sets: Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturershall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ wo rk , refer Annexure A attached with this BSR . 50 to 82.5 kva 179 5.10.4Add extra for each subsequent lead of 1 km or part there of beyond 5 Km 180 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mmnominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS: 694) in recessed ISI marked ( IS:9537 P - II ) rigid steel conduit & its ISI marked (IS:14768P-II 2003) accessories, round tiles,Hot Dipped Galvanized Modular Box of 1.2 mm thick with earth terminal, 10A Modular switch,3 pin ceiling rose / holder / 3 way connector ,Modular faceplate with grid plate, pvc bushes, check nuts, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR i- shortpoint (upto 3 Mtr) 181 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mmnominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS: 694) in recessed ISI marked ( IS:9537 P - II ) rigid steel conduit & its ISI marked (IS:14768P-II 2003) accessories, round tiles,Hot Dipped Galvanized Modular Box of 1.2 mm thick with earth terminal, 10A Modular switch,3 pin ceiling rose / holder / 3 way connector ,Modular faceplate with grid plate, pvc bushes, check nuts, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR ii - Medium point (upto 6 Mtr) 182 11.5.1Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required.Up to 5 m. depth 183 Structural steel work riveted or bolted in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete above plinth level upto 4.5 mtr height.In flats, tees, angles and channels. 184 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mmnominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS: 694) in recessed ISI marked ( IS:9537 P - II ) rigid steel conduit & its ISI marked (IS:14768P-II 2003) accessories, round tiles,Hot Dipped Galvanized Modular Box of 1.2 mm thick with earth terminal, 10A Modular switch,3 pin ceiling rose / holder / 3 way connector ,Modular faceplate with grid plate, pvc bushes, check nuts, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR iii - Long point (upto 10 Mtr) 185 Rewiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVCinsulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & its ISI marked (IS:3419-1988)accessories, 1.2 mm thick MS box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy /Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR :on board 186 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity(B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulsewithstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2,low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 40A rating 187 P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fanhook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 188 Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirementslaid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work , refer Annexure A attached with this BSR . 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 189 Providing & Fixing of IS 11037:1984 marked non modular socket size flush type 180 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial gradePolycarbonate or fire resistant ABS material including making connection testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parametersof products/ work , refer Annexure A attached with this BSR . 190 Providing & Fixing of IP 20 box made out from 1.2mm thick CRCA sheet steel with depth of minimun 30 mm and finished with powder coating and suitable for mounting LED tubeincluding side covers, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube). All as per pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure A attached with this BSR 191 Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI>70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure A attacheded with this BSR. 9 watt 192 P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nutand bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR : 4.8 mm thick 193 Providing & Fixing of ISI marked (IS:1258) batten/angle lamp holder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brassterminal & captive screwsincluding making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work ,refer Annexure A attached with this BSR 194 providing of 18mm wire rope galvanised 6x36 construction IWRC (steel core) RHOL (right hand ordinary lay) & tensile strength of 1960 N/mm confirming to IS :2266/89 195 Chair type 7 {Revolving chair medium back, support backrest symmetrical lumber support, back cover mesh fabric) (inclusive all taxes) 196 Dressing of earth work in surface excavation including cutting and filling upto 30cm depth including disposal of excavated earth upto 50m and lift upto 1.5 m. 197 Providing laying, spreading and compacting stone aggregates of specific sizes as per Table 400-7 to Water Bound Macadam specification including spreading in uniform thickness; handpacking, rolling with power roller 8-10 tonnes, in stages to proper grade and camber, applying and brooming requisite type of screening (Table 400-8) binding materials to fill up theinterstices of coarse aggregates, watering (with water browser) and compacting to required density, making necessary earthen bund to protect edges as per clause 404 of MoRT&Hspecification including all material, labour, machinery, lighting, guarding and maintenance of diversion complete : Crusher broken Grade II (63-45 mm) 198 Providing and laying lean cement concrete 1:4:8 in Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in concrete mixer, laid manualy, compacted with surface vibrator, finishing and curing complete as per clause 601, 112 of MoRT&H specificationincluding all material, labour, machinery, lighting, guarding and maintenance of diversion 199 Chair type 4 {chair type with arms,frame type 4 legs,castors without (inclusive of all taxes)} 200 Providing and laying un-reinforced, dowel jointed, plain cement concrete mix With Concrete Mixer & vibrator pavement over a prepared sub base with 43 grade cement , coarse and fineaggregate conforming to IS: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed as per approved mix design, laid, spread, compacted and finished in a continuousoperation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures (if required) as approved, curing compound, finishing to lines and grades complete as per drawing and as per clause 602, 112 of MoRT&H specification including all material, labour,machinery, lighting, guarding and maintenance of diversion. PCC M-25 201 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz±3%, Power Factor >0.95 ,driver Efficiency >85% , THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be rovided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K ±355K. Driver current <1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow raceability/authenticity. Fixture shall be IS 10322 Complianced. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures . (LM79/LM80) certificate/report with liable warranty of product/accessories from OEM shall be submitted . All as per approved by Engineer In charge . for additional technical parameters of products/works . High Power LED Flood 202 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primer. M.S tube 203 Octagonal MS Poles made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. 4 meter 204 Supply, Erection and Fixing of hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved byEngineer in charge. For additional technical parameters of products/ work . Double arm overhang 205 providing of 24 mm wire rope galvanised 6x36 construction IWRC (steel core) RHOL (right hand ordinary lay) & tensile strength of 1960 N/mm confirming to IS :2266/89 206 Supply installation testing & Commissioning of ISO certified company made high mast lighting system (as per PLG 07 of ILP UK techinical report no 7 of ILE UK /IS:875 Part-1 –2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstruction lights, double drum type self sustaining winch, inte gral power tool accesible from door with padlocking arrangement ( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, S.S. ropes (AISI 316, 7 / 19 costruction ), EPR insulated PCP sheathed trailing cable, including outdoor type control panel for auto on / off, reverse / forward motor operation and CC foundation of M - 25 grade complete as required as per IS 456/IS 2911. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal section, telescopic jointed and welding as per BS 5135. ( See table P - 03 for specs.) OEM must have type test certificate for wind tunnel test for high mast fixtures , complete in all respect .All asper pre approved by Engineer in charge ,for additional technical parameters of products/work. 16.0 Mtr HM(in 2section) 207 Labour charge for removing old wire ropes and fixing of new wire ropes with all accessories and T&P etc complete 208 oiling & greasing of gantry crane on Parbati Dam Which includes complete Removal of all old worn out & broken down parts, cables, connections etc complete checking of all copper wiring, all wiring & connections control panel , all switches etc complete with all material , labout, T&P and lead and lift complete in all respect 209 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approvedbrand or manufacture 210 Providing and fixing of precast concrete interlocking tiles of desired shape of M 30 grade manufactured from fully computerized automatic stationery hydraulic vibrio pressed machine and fully computerized automatic batching plant of class A1/A2 as per BS 6717:2001. The CC interlocking paving blocks be laid on average 50mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer in charge. The rates to be inclusive of all lead & Lifts etc. complete as per specifications. Tensile splitting strength, abrasion and braking load etc. as per BS 6717:2001, Grey cement. : 80mm thick 211 Table type 3 (storage provided one side,length of table top-1200 mm, depth of table top-600 mm) 212 Providing sofa set(Frame covering fully upholstered, Total No of seats in sofa set -4, covering material for seat and back rest-leatherite) 213 Table type 5 (seating capacity - 8 seater, width in mm -1200, Length in mm - 2400mm, shape of table top Rectangular , height in mm - 750 mm ) (inclusive all taxes)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
17.
Health and Family Welfare #10276803 Price Bid
Tender For Electrification Work At Construction Of Chc Building At Jhinjhiyali District Jaisalmer - Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 20 mm 13 25 mm 14 32 mm 15 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 16 1 x 1.5 sq.mm 17 2 x 2.5 sq. mm. + 1x1.5sqmm 18 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 19 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. 20 1 x 4.0 sq.mm 21 4 x 6.0 sq.mm 22 4 x 10.0 sq.mm 23 Providing & Fixing of ISI marked surface type buzzer (IS:2268-1994) with CM/L no. printed including making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 24 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 25 75 mm dia 26 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 27 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 5 step fan regulator 2 Module 360 dgree rotating 29 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 30 Blanking plate 31 25 Amp. 2 Module Motor Starter with on / off Push button 32 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 33 25 Amp. 2 Module Socket 34 Providing & Fixing ofextra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steelpipe including cutting, threading, drilling, fixing quarter pin etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 35 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 36 Up to 380 mm size 37 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 38 3 pair 39 5 pair 40 50 pair 41 20 pair 42 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 43 20 Pairs 44 50 Pairs 45 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 46 1.2 mm thickM. S. Sheet boxes 47 175mm x 100mm x 60mm 48 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 49 3.0 mm thick 50 Providing & Fixing of flush typenon modular single line telephone jackmade out fromindustrial grade Polycarbonate or fire resistant ABS material, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 51 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 52 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 53 Cat 6, Un-sheilded Information Outlet 54 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 55 Single Aperture 56 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 57 Single pole MCB (With B/C curve tripping Characteristics) 58 6 A to 32 A rating 59 Triple pole MCB(With B/C curve trippingCharacteristics) 60 6 A to 32 A rating 61 50/63 A rating 62 Four pole MCB (With B/C curve tripping Characteristics) 63 6 A to 32 A rating 64 50/63 A rating 65 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 66 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 67 6Way(Incomer 8,Sub Incomer2+2+2) 68 8Way(Incomer 8,Sub Incomer2+2+2) 69 Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock,min. operation 10,000 upto 63 A rating and5000 for 100 Aratingand minimum phase termination capacity of 35 sq.mm. rigid wire, IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 70 Two pole 100/300mA sensitivity 71 63 A rating 72 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 73 Double door IP-43 & IK-09 with Provision of Incomer MCCB 160 A Rating with Metal end box 74 6 Way 75 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 76 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 77 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 78 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 79 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 80 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 81 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 82 17.2 mm thick and 3 Mtr. Long 83 Plate Earthing as per IS:3043 withcopper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying3 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 84 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 25mm x 3mm copper strip 86 25mm x 3mm G.I. ( Hot Dipped) Strip 87 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 89 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 90 300 mm sweep(900/1400 RPM) 91 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 225 mm sweep 93 Providing & Fixing of 450 mm SweepOscillating type Wall mounting / Pedestal typefans with Three speed, ON andOFF position, Sintered Iron bush oil impregnated,with metal front and back 120 or moreribs guard; Three no. Aluminiumblades, minimum Air delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum./min/watt, noise level should be <= 75 dB, power consumption <= 120 watts, motor protection through thermal overload protection device, including fixing with anchor bolts, making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 Wall mounting type with Adjustable Vertical Angle 95 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 97 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 98 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 99 Surface Moutning 100 Minimum lumen output 3600 lm 101 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 102 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 103 Surface Mounting (with extruded alumn. Housing ) 104 Minimum lumen output 1950 lm 105 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 106 6.0 Sq. mm 107 4 core 108 10.0 Sq. mm 109 4 core 110 16.0 Sq. mm 111 4 core 112 25.0 Sq. mm 113 3.5 core 114 50.0 Sq. mm 115 3.5 core 116 70.0 Sq. mm 117 3.5 core 118 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 119 4 x 6.0 sq.mm 120 4 x 10.0 sq.mm 121 4 x 16.0 sq.mm 122 3.5 x 70.0 sq.mm 123 3.5 x 50.0 sq.mm 124 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 125 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 126 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 127 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 128 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 129 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 130 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 131 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 132 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 133 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 134 Electrolytic grade Aluminium bus bar 6010 grade 135 Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type(up to 500) V range Volt meter / Direct- Ammeter /CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracyas per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 136 Three phase Ammeterwith Inbuilt Selector Switch 137 Three phase Voltmeter with Inbuilt Selector Switch 138 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 139 Ring type tape wound CT 140 C T Class 1, Ratio upto 150/5, Burden 5 VA 141 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 142 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 143 Red/yellow/Green colour 144 Providing & Fixing of Electricalinsulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006with one sideanti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 145 11 KV,Class B 2.5 mm thick with proof voltage 22 KV AC (rms) and Break Down Voltage45 KV AC (rms) 146 Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) conforming to IS:13340-41 /IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, llife expectancy greater than 100000hrs(temp class - 25 D)in 440 V/480 V Capacitor and for 525 V should life expectancy minimum 1,65,000 hrs (temp class - 25 D)including making connections, testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 147 Heavy dutyThree phase 480 V, 50 Hzcylindrical type capacitor (Bank) 148 Providing & Fixing of IP54 microprocessor based 3 CT’s for all 3 phasesensing compensationpower factor correction relay Size 139mm x 139 mm, Operating Voltage 415/440 V, IEC / EN 61000-6-(2&4)having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall havedigit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485,indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR, RMS Value, step switching time 2 sec to 1800 sec. Lead & Lag parameters, metering facility and3 no. Class- 0.5 Cast ResinCT ( refer CT specs in this chapter )for sensing the relay including making coonection with 1.5 Sq.mm copper wire etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 149 6 to 8 stage 150 Providing & Fixing of440 Volt 3 pole capacitor(AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current as per PWD specification for electrical Works,IS/IEC 60947-4-1 : 2000, insulation voltage 1000V, impulse withstand voltage 8 KV,Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 151 up to 6 KVAR 152 10 KVAR 153 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 154 3 pole MCCB With Thermal Magnetic release 155 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 156 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 157 4 pole MCCB With Thermal Magnetic release 158 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 159 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 160 250 Amp , 35 kA, adjustable O/L & adjustable S/C setting, 161 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 162 LED Street Light fixture with Minimum lumen output 3700 lm 163 LED Street Light fixture with Minimum lumen output 8700 lm 164 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 165 SITC of Single Stage, water cooled, High Speed (2880 RPM), Horizontal, Centrifugal, Openwell Submersible pumps set pre filled with coolent water and fitted with mechanical seal - T/C Vs T/C, Thrust bearing shall be ofcarbon + S.S.The stator body of single phase pumpshall be of SS and rest of all shall be of cast iron. All casting parts should be cathod electro deposition (CED) coated and other construction material should be confirming to IS : 14220: 2018 . The overall performance of pump shall confirm to BEE energy efficiency level of 3 star. Valid BEE certificate from OEM must be submitted for the same. Motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011, including making connection etc as required complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 166 1.5 HP, 1-Ø, (18 -26) Mtr, (126 - 78) LPM 167 Supply & fixing of GI pipes confirming to IS : 1239 P - 1 ( 2004 ) with flanges duly screwed & welded including rubber washer, nuts & bolts of 8mm dia complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 168 B class 50mm dia 169 SITC of ContactorOEM Fabricated DOL/Star-Delta Starter panel with switchgear selection as per Type-2 Cordinatiom Chart andmade out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, Illuminated ON / OFFpush buttons,ammeter, voltmeter, indicating lamps etc.suitable for following rating motors complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 170 For Three phase Submersible / Mono block pump 171 3.0 HP to 5.0 HP ( Star / Delta starter ) 172 P/Laying ISI marked P.V.C. insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen freefor less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,existing pipe / open trench / Cable tray / on surface including making connection etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 173 6.0 Sq.mm 3 core flat / Round 174 Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 175 150mm x 50mm x 1.6mm 176 P & F in position frame made out of M.S. angle (riveted or welded) finished with two coats of red oxide and two coats enamel paint including cutting, welding, holes etc.of following sizes as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 177 50mm x 50mm x 6mm 178 35mm x 35mm x 5mm 179 Providing & Fixing ofCam operated rotary (Auto/manual) switches on existing panel with 2 way and off position using high grade engineering materialto international standards with cam assemblyinsulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc.as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 180 10 AMP 181 32 AMP 182 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 183 Open execution type 184 125 A 185 Supply and erection ofGalvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 186 Poles with Octagonal Cross Section 187 7 Mtr. 188 Providing and fixing of IP 65 protected Polycarbonate / Polysterene fuse box moulded with inside knock outs of following size with hinged cover, transparent window,PU gasket, locking arrangement, duly holded with 2 nos. pole clamps of 20 mm x 3 mm flat with nut and bolts, The box shall be provided with Din rail, 4 / 8 way 10.0 / 16.0sq.mm heavy duty connector, earth terminal,complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 189 160 mm X 225 mm X 100 mm 190 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 191 Providing & Fixing offollowing size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 192 1/2 Module 193 3 Module 194 Providing & Fixing ofWiring Accessories OEM fabricated following size GI box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 195 1-2 Module 196 3 Module 197 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 198 15 Ltr. 199 Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 200 Single arm overhang 201 SITC of Radiator Cooled and Turbo charged Silent DG Set (As per latest CPCB emissionnorms) havingspecifications as per A, B, C, D, E, F,G,H & I 202 A) 1500 RPM Diesel Engine conforming to BS:649/5514 of suitable BHP(up to 82.5 kVA 6 cylinder or Below required, 125 kVA & Above ratings 6 cylinder or aboverequired ) capable of taking 10% over loading for one hour after 12 hours of continuous operation.,Dry exhaust mainfold with Hospital grade silencer and catalytic convertor(isolated from main DG chamber),up to 3 M exhaust piping (with LRB insulation & Alum. cladding ) as required . 203 B)AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS/IEC 60034-1. . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled 204 C) CPCB / ARAI approved Standard canopy with Weatherproof, powdercoated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with sidewall fabricated from 1.6 mm CRCA sheet & filled with glasswool (96Kg/m3) / Foam. as per IS8183 the doors of 28/40/50/85mm thick as perrating and fabricated from 1.6mm CRCA sheet packed with accoustic material, All doors/opening are sealed with neoprene /EPDNgaskets. The DG Set has Inbuilt / External in fuel tank to run 6 to 8 Hrs as per OEM standard, with protection and tripping of DG set against temperature of more than 50 degree centigrade. 205 D) Electronic / Mechanical governor, Manual & electric Start ,Batteries with battry charger,Engine instruments panel,AVM pads All controls for operation of DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Panel mounted MCCB/ACB of suitable rating, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level shall be less than 75 dB at a distance of 1 Mtrs. duly certified by authorised agency etc. complete in all respect of following capacity : 206 E) (i) Accoustic glass wool wall thickness should not be less then 40mm and not less then 20mm PU foam upto rating 100 KVA. (ii).Accoustic glass wool wall thickness should not be less then 65mm and not less then 50mm PU foam upto rating 250 KVA. (iii)Accoustic glass wool wall thickness should not be less then 100mm forrating above 250 KVA. 207 F) First filling of the fuel tank shall be done by contractor and the prevailing fuel cost at that time shall be reimbursed to the contactor by department. 208 G) Servicing Contract of DG Set from OEMs Authorised Service Dealer as per OEM guidelines during the DLP period shall be done by contractor including all consumables, actual charges shall be reimbursed to the contractor by End User Department. 209 H) Manufacturer / OEM must have its authorized service dealer in Rajasthan. Which can provide service within 6 Hours of compalint registration. 210 I) DG set will be offered for Inspection and Testing at Manufacturers Works in presence of Departmental Engineers. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 211 50 KVA at 0.8 pf 415V 50Hz 3-ǿ 212 SITC of PLC Based Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stopcommands, control Relays , Ammeter & Voltmeterwith selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets: Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturer shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 213 50 to 82.5 KVA 214 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 215 8 SWG copper Wire 216 Providing, Fixing, Jointing, Testing & Commissioning of Medium duty MS B class pipes conforming to IS 3589 / 1239 part-I for DG Exhaust applications (beyond 1.5 Mtr. length)includingcutting,welding etc & fittings like elbows,flanges, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts . including the cost of thermal insulation with 50 mm thick layers of LRB rock wool as per IS : 8183-1993 (64 kg/m3 density) & 26 SWG aluminium sheet claddings etc complete as required complete in all respect.(Cost of Steel Structure for Exhaust pipe will be paid Extra). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 217 125 mm dia 218 P & F of Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 219 Supply, installation, testing & commissioning of following size & Material air termination rods confirming to IEC/EN 62561 with suitable OEM recommendedmounting arrangement on parapet wall all as per standard , complete as required. the test report accredited by third party accreditation body like VDE/ ILAC/ DAkkS/ UL/ NABL is to be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 220 1500 mm long, 10 mm Dia. Aluminium / AlMgSi 221 Supply & Fixing Air-termination rod clamps for connecting air-termination rods with one or two conductors. Material of clamp Al, with clamping range of air-termination rod 10 / 16 mm and Clamping range of conductor Rd 2x 8-10 mm, & Complied as per Standard EN 62561-1, tested to carry from 100KA (10/350μs) lightning current the test report accredited by third party accreditation body like VDE/ILAC/ DAkkS/ UL/ NABL is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 222 Supply and Fixing of stainless steel clamp for holding 8mm dia. conductor on Parapet Wall / Side Fl 20 mm, Height- 20 mm & Complied as per Standard EN 62561-4. With accessories SS Screw and Gitty etc. as required. the test report accredited by third party accreditation body like VDE/ILAC/ DAkkS/ UL/ NABL is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 223 Supply & LayingofAluminum / SS / AlMgSi Round Conductor confirming to IEC/EN 62561 etc. as required. the test report accredited by third party accreditation body like VDE/ILAC/ DAkkS/ UL/ NABL is to be submitted. ( Supporting Clamps to be paid Extra )All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 224 8 mm Dia. Aluminium conductor 225 Supply and Fixing of Test Joint (Folding Clamp) made of SS,suitable to connect 8mm round conductor with25 mm x 6 mm GI strip etc. as required. the test report accredited by third party accreditation body likeVDE/ILAC/ DAkkS/ UL/ NABL is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 226 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 227 24 Ports 228 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 229 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 230 1 Mtr 231 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 232 9 U Rackwith Width 600 mm & Depth 400 mm + 100 mm 233 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 234 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 235 1.5 TR ISEER not less then 3.8 236 2.0 TR ISEER not less then 3.8 237 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 238 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 239 4 kVA 240 5 kVA 241 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 242 25 mm 243 SITC of Interconnecting refrigerantcopper pipe forsplit/Ductable/ Casseette AC of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. Piping between each set of indoor & outdoor units of different sizesas per OEM requirement & specifications including class O Nitrile rubber sleeves, chase cutting, supports, making good the same with sand cement plaster etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 244 Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existingsurface or recessed PVC/ MS conduit/casing capping/ Cable tray / Open Duct making connections, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for cables. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 245 Armoured 246 4 core x 2.5 Sq.mm 247 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 248 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 249 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 250 4 kg 251 Supply & Fixing of CO2 type Fire Extinguisher conforming to IS:15683:2018, charged with CO2 gas (purity 99.7% conforming to IS 15222), Powder coated Internal & External Surface Manganese steel ISI marked as per IS 7285 cylinder body , Wheel type Forged brass release valve ISI Marked as per IS 3224 with Inbuilt safety release device ((Fusible plug and Rupture Disc Type), 1.0 Mtr. Metal wire braided hose having minimum bursting pressure of 140 Kgf/cm2, Horn with metallic thread connection, QR code for Product Traceability,including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 252 Capacity 4.5 Kg.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
18.
Health and Family Welfare #10267207 Price Bid
Cardiac Cath Lab With Ep Facility Model A , Cathlab Machine As Per The Specification Except The Following , Medical Grade Large High Definition Fhd Display 55 , Four Medical Grade High Definition Display Lcd / Led Flat 19 Or Higher Monitors With Wide Viewing Angle, High Luminance High Contrast, Flicker Free, Distortion Free , Electrophysiology Application , Workstation As Per Spec , High Pressure Injector With 200 Syringes , Online Ups For Cathlab & Accessories , Console, Workstation, Lights And Computer , All In One Computer With Laser Printer , 12 Channel Ecg With Pc Connectivity , Full Wrap Around Lead Aprons , Skirt ( With Fastening Belt ) -Vest Type Lead Aprons , Front Fulltype Lead Apron , Light Weight Leadless Single Piece Aprons With Front And Back Coverage , Light Weight Leadless Skirt And Vest With Fastening Belt , Thyroid Guard Lead Less , Leadless Head Gear Radiation Protection And Light Weight Lead Goggles , Lead Stockings , Lead Spectacles , Lead Gloves , Heavy Duty Stand With Hangers To Hold Atleast 5 Lead Aprons ( Stainless Steel 304 Construction ) , Wall Mounted Hangers To Hold Atleast 5Lead Aprons , Intercom Between Exam And Control Room , Instrument Table , Accessory Table , Buy Back Offer Of Existing Cathlab Model Philips Allua Fd10 Installed At Mch Kottayam , 15.3 Demolishing R.C.C. Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material With In 50 Metres Lead As Per Direction Of Engineer -In-Charge. , 15.7.4 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar , 15.12.1 Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below , 15.12.2Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead: Of Area Beyond 3 Sq. Metre , 15.23.1Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm , 15.57 Dismantling Aluminium / Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Surplus Material And Stacking Of Serviceable Material With In 50 Metres Lead As Directed By Engineer - In-Charge , 2.34.1Supplying Chemical Emulsion In Sealed Containers Including Delivery As Specified.Chlorpyriphos / Lindane Emulsifiable Concentrate Of 20% , 2.35.1.1Diluting And Injecting Chemical Emulsion For Post -Constructional Anti-Termite Treatment ( Excluding The Cost Of Chemical Emulsion ) :Along External Wall Where The Apron Is Not Provided Using Chemical Emulsion @ 7.5 Litres / Sqm Of The Vertical Surface Of The Substructure To A Depth Of 300Mm Including Excavation Channel Along The Wall & Rodding Etc. Complete: With Chlorpyriphos / Lindane E.C. 20% With 1% Concentration , 24.2Providing And Fixing Double Scaffolding System ( Cup Lock Type ) On The Exterior Side Of Building / Structure, Upto 25 Metre Height, Above Ground Level, Including Additional Rows Of Scaffolding In Stepped Manner As Per Requirement Of Site, Made With 40 Mm Dia M.S. Tube, Placed 1.5 Metre Centre To Centre, Horizontal & Vertical Tubes Joint With Cup & Lock System With M.S. Tubes, M.S. Tube Chakkus, M.S. Clamps And Staircase System In The Scaffolding For Working Platform Etc. And Maintaining It In A Serviceable Condition For Execution Of Work Of Cleaning And / Or Pointing And / Or Applying Chemical And Removing It Thereafter. The Scaffolding System Shall Be Stiffened With Bracings, Runners, Connecting With The Building Etc, Wherever Required, If Feasible, For Inspection Of Work At Required Locations With Essential Safety Features For The Workmen Etc., Complete As Per Directions And Approval Of Engineer-In-Charge. Note: - ( 1 ) The Evaluational Area Of The Scaffolding Shall Be Measured For Payment Purpose, ( 2 ) The Payment Will Be Made Once Only For Execution Of All Items Of Such Works. , 15.60 Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved , 50.2.25.1 Filling With Contractors Own Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M As Per Direction Of Site Engineer-In-Charge , 50.4.1.1 Providing And Laying In Position Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size ) Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing For Leveling Coarse Of Floor And Roof Etc. , 50.5.5Reinforced Cement Concrete Work In Arches, Archribs, Domes, Vaults, Shells, Folded Plate And Roof Having Slope More Than 15 Degree Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand: 3 Graded Stone Aggregate 20 Mm Nominal Size ) . , 50.5.33.2 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-20 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. Note:- Cement Content Considered In This Item Is @ 330 Kg / Cum. Excess Or Less Cement Used As Per Design Mix Is Payable Or Recoverable Separately. All Work Above Plinth Level Upto Floor V Level , 5.22.1 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelmild Steel And Medium Tensile Steel Bars , 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform , 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil , 6.26.2Brick Work With Common Burnt Clay Selected F.P.S ( Non Modular ) Bricks Of Class Designation 7.5 In Exposed Brick Work Including Making Horizontal And Vertical Grooves 10 Mm Wide 12 Mm Deep Complete In Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) Above Plinth Level And Upto Floor V Level , 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks ( Factory Made ) Of Size 40X20x20cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand ) Etc Complete. , 50.6.1.8 Solid Block Masonry Using Pre Cast Solid Blocks ( Factory Made ) Of Size 40X20x15cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In: Cm 1:6 ( 1 Cement : 6 Coarse Sand Etc Complete , 50.6.3.2 Solid Block Masonry Using Pre Cast Solid Blocks ( Factory Made ) Of Size 40X20x10 Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level For 10 Cm Thick Wall In : Cm 1:6 ( 1 Cement : 6 Coarse Sand ) Including Cost Of Scaffolding Complete , 13.1.1Cement Plaster12 Mmof Mix: 1:4 ( 1 Cement : 4 Fine Sand ) , 13.7.1Cement Plaster 12 Mmfinished With A Floating Coat Of Neat Cement Of Mix: 1:3 ( 1 Cement : 3 Fine Sand ) , 11.37Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm ( Thickness To Be Specified By The Manufacturer ) , Of 1St Quality Conforming To Is : 15622, Of Approved Make, In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. , 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. , 11.41.3 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 800X 800 Mm , Od31976 / 2023_2024Providing And Fixing First Quality Vitrified Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , 11.48.2 Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade ( 0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg ) . Including Filling / Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge. Size Of Tile 600X600 Mm , 11.48.3Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade ( 0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg ) . Including Filling / Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge.Size Of Tile 800X800mm , 11.55.1 Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm ( Average ) Thick Base Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge :Flamed Finish Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , 50.9.1.1Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length ( Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately ) , Using Good Quality Anjili Wood / Jack Wood , 50.9.2.1Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineerin - Charge. Using Anjili / Jack Wood , 21.1.1.2 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) : For Fixed Portionpowder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) , 21.1.2.2 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately ) Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge.Pre- Laminated Particle Board With Decorative Lamination On Both Sides , Od31977 / 2023_2024 Supplying And Fixing Flush Door Shutter, Shutter Of Required Size, Thickness 30Mm Thick, Finished With 1 Mm Laminate Of Approved Shade With 9 X 16 Clear Glass Vision Panels As Per Design Including Necessary Hinges , Od31978 / 2023_2024 Frosted Film - Supply And Installation Of 3M Make Frosted Film Pattern Throughout All The Internal Glass Panels Wherever Required Of Approx. 1.5 M Height As Per The Approved Pattern. , Od31979 / 2023_2024 Providing And Fixing Extruded Section Body Tubular Type Universal Hydraulic Door Closer ( Having Brand Logo With Is: 3564, Embossed On The Body, Door Weight Upto 36 Kg To 80 Kg And Door Width From 701 Mm To 1000 Mm ) , With Double Speed Adjustment With Necessary Accessories And Screws Etc. Complete , Od31980 / 2023_2024 Providing And Fixing 4.00 Mm Thick Acp Sheet For Cupboard Including All Cost, Conveyance, Labour Charges Etc Complete , 21.3.1 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) : With Float Glass Panes Of 4.0 Mm Thickness , 12.45.2 Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms / Sqm ( Both Side Inclusive ) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37 Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50 Mm Long With 6 Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall / Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25 Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5X25 Mm At 230 Mm C / C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound, Jointing Tapes, Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With: 12.5 Mm Thick Tapered Edge Gypsum Fire Resistant Board Conforming To Is; 2095-Part I , 12.54.1 Providing And Fixing Gi Clip In Metal Ceiling System Of 600X600 Mm Module Which Includes Providing And Fixing C Wall Angle Of Size 20X30x20 Mm Made Of 0.5 Mm Thick Pre Painted Steel Along The Perimeter Of The Room With Help Of Nylon Sleeves And Wooden Screws At 300 Mm Center To Centre, Suspending The Main C Carrier Of Size 10X38x10 Mm Made Of G.I Steel 0.7 Mm Thick From The Soffit With Help Of Soffit Cleat 37X27x25x1.6 Mm, Rawl Plugs Of Sixe38x12 Mm And C Carrier Suspension Clip And Main Carrier Bracket At 1000 Mm C / C. Inverted Triangle Shaped Spring Tee Having Height Of 24 Mm And Width Of 34 Mm Made Of Gi Steel 0.45 Mm Thick Is Then Fixed To The Main C Carrier And In Direction Perpendicular To It At 600 Mm Centers With Help Of Suspension Brackets. Wherever The Main C Carrier And Spring T Have To Join, C Carrier And Spring T Connectors Have To Be Used. All Sections To Be Galvanized @ 120 Gms / Sqm ( Both Side Inclusive ) , Fixing With Clip In Tiles Into Spring T With :Gi Metal Ceiling Clip In Plain Beveled Edge Global White Color Tiles Of Size 600X600 And 0.5Mm Thick With 25 Mm Height, , Made Of G.I Sheet Having Galvanizing Of 100 Gms / Sqm ( Both Sides Inclusive ) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns ( Minimum ) , Including Factory Painted After Bending . , 12.58.1 Providing And Fixing Tiled False Ceiling Of Approved Materials Of Size 595X595 Mm In True Horizontal Level, Suspended On Interlocking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanized @ 120 Grams / Sqm, Both Side Inclusive ) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick ( Minimum ) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet, 1200 Mm Long Space Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel To Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting / Making, Opening Of Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Of Size 27 X 37 X 25 X 1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gi Adjustable Rods With Galvanized Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. 8Mm Thick Fully Perforated Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Autoclaving Process To Give Stable Crystalline Structure With Minimum Compressive Strength 225 Kg / Sq. Cm, Bending Strength 100 Kg / Sq. Cm, Of Size 595X595 Mm, Having Perforation Of Dia, 10 Mm With Minimum Perforated Area 18% With Non Woven Tissue On The Back Side, Having An Nrc ( Noise Reduction Coefficient ) Of 0.85, With 50 Mm Thick Rockwool Of 48 Kg / Cum Backing. , 21.4.2Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is: 6315, Having Brand Logo Embossed On The Body / Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors, Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Engineer -In- Charge.With Brass Cover Plate Minimum 1.25 Mm Thickness , 21.13 Providing And Fixing 100 Mm Brass Locks ( Best Make Of Approved Quality ) For Aluminium Doors Including Necessary Cutting And Making Good Etc. Complete , 50.9.11.1Providing And Fixing Thomson Multi Wood Board Or Equivalent Make Paneling 12 Mm Thick, To Frame, Backing Or Studding With Screws Etc. Complete ( Frames, Backing Or Studding To Be Paid Separately ) As Per The Direction Of Site Engineer-In-Charge. , 50.9.12.1 Providing And Fixing Thomson Multi Wood Board Or Equivalent Make, In Shelves With Screws And Fittings Wherever Required, Edges To Be Painted With Polyurethane Primer ( Fittings To Be Paid Separately ) As Per The Direction Of Site Engineer-In-Charge. , 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work , 13.69.1 Polishing On Wood Work With Ready Mixed Wax Polish Of Approved Brand And Manufacture: New Work , 13.80Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , 13.83.2Wall Painting With Premium Acrylic Emulsion Paint Of Interior Grade, Having Voc ( Volatile Including Applying Additional Coats Wherever Required To Achieve Even Shade And Colour.Two Coats , 13.47.1Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work ( Two Or More Coats Applied @ 1.43 Ltr / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) , 10.16.3 Steel Work In Built Up Tubular ( Round, Square Or Rectangular Hollow Tubes Etc. ) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Electric Resistance Or Induction Butt Welded Tubes , Od31981 / 2023_2024Roofing Sheet With Sandwich Puf Roof Panel With 0.40 Mm Or Nearest Size Pre Painted Galvalume Sheet At Top & Bottom , 30 Mm Or Nearest Size Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete , Od31982 / 2023_2024 Wall Cladding With Sandwich Puf Wall Panel With 0.40 Mm Or Nearest Pre Painted Galvalume Sheet At Top &Bottom , 30 Mm Or Nearest Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete. , Od31983 / 2023_2024 Providing At All Heights, Levels And Locations 0.45 Mm Thick Galvalume Sheet Of Alloy 31500 / 31000 / 40800, Conforming To Is 1254, Is 737, Is 2676. The Sheet Shall Be Fixed Using Self Drilling / Self Tapping Ss Screws Of Size 5.5X65 Mm With Epdm Seal Complete Upto Required Pitch In Horizontal, Vertical Or Curved Surfaces I / C Cutting To Size And Shape Where Required As Per The Direction Of Engineer-In-Charge. The Rate Shall Be Inclusive Of All Screws, Seal, Ridge, Labour, Scaffolding, Machinery For Fixing And Approved Sealant Where Required Etc. But Excluding The Cost Of Purlins, Rafters And Trusses. , 17.2.2 Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , 17.7.1 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps , 50.17.1.2 Supplying And Fixing Cp Towel Rod 45Cm Or Nearest Available Length Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge , 50.17.1.5Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 50.17.1.1 Supplying And Fixing Stainless Steel Soap Dish Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 17.31 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Od33878 / 2023_2024 Supplying And Fixing Stainless Steel Mirror Finished H Type Handles Including Material Cost, Conveyance And Fixing Charges Etc Complete. , 50.18.7.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 15Mm Dia 12Kgf / Cm2 -Internal Work- Exposed On Wall , 50.18.7.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mm Dia 10Kgf / Cm2- Internal Work - Exposed On Wall , 50.18.8.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer- In- Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 15 Mm Pipe 12 Kgf / Cm2 , 50.18.8.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 32 Mm Pipe 10Kgf / Cm2 , 50.18.8.9.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chased And Making Good The Wall Etc. 110 Mm Pipe 6Kgf / Cm2 , 50.18.9.8.2 Providing And Fixing Pvc Pipes Includings Of Pipes With One Step Pvc Solvent Cement, Trenching And Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 75 Mm Dia 4 Kgf / Cm2 , Od31984 / 2023_2024 Providing And Fixing 24 Mm Thick Factory Made Pvc Door Shutters Made Of Styles And Rails Of A Pvc Hollow Section Of Size 59 X 24 Mm And Wall Thickness 2 Mm With Inbuilt Edging On Both Sides. The Styles And Rails Mitered And Joint At The Corners By Means Of M.S. Galvanized / Plastic Brackets Of Size 75 X 220 Mm Having Wall Thickness 1.0 Mm And Stainless Steel Screws. The Styles Of The Shutter Reinforced By Fixing Galvanized M.S. Tube Of Size 20 X 20 Mm And 1 Mm Wall Thickness. The Lock Rail Made Up Of H Section, A Pvc Hollow Section Of Size 100 X 24 Mm And 2 Mm Wall Thickness, Fixed To The Shutter Styles By Means Of Plastic / Galvanized M.S. U Cleats. The Shutter Frame Filled With A Pvc Multi-Chambered Single Panel Of Size Not Less Than 620 Mm, Having Over All Thickness Of 20 Mm And 1 Mm Wall Thickness. The Panels Filled Vertically And Tie Bar At Two Places By Fixing Horizontally 6 Mm Galvanized M.S. Rod And Fastened With Nuts And Washers, Complete As Per Manufacturers Specification And Direction Of Engineer-In-Charge ( For W.C. And Bathroom Door Shutter ) . , Od31985 / 2023_2024 Supplying And Fixing Name Board Of Various Sizes Using Foam Sheet Board Including Lettering As Per The Direction Of Departmental Officers Including Cost, Conveyance And Fixing Charges Etc Complete. 45X14cm Size , Od31986 / 2023_2024 Supplying And Fixing The Name Board Of Size 80 X 30 Using Acp Board With Acrylic Lettering Including Cost, Conveyance And Labour Charges For Lettering And Fixing Etc Complete , Od31987 / 2023_2024 Supplying And Fixing Inaugration Board Using Granite Slab Including Lettering As Per Direction Of Departmental Officers Including Cost Of Granite, Lettering And Fixing Charges Etc Complete. Size: 100X84cm , Supplying And Fixing Skylight Of Size 1.2Mx 1.8M With Designed Acrylic Sheet Including 4 Numbers Led Tube As Per The Direction Of Engineer In Charge , Od31989 / 2023_2024 Computer Chair The Medium Back Adjustable Revolving Chair Made With Mesh Back Within Built Handle In The Nylon Finish, The Back Is Designed Extra Lumber Support. The Seat Have Provided Seat Cover In Pp Made With 12Mm Hot Pressed Ply And Pu Moylded Foam. The Tilting Mechanism Should Be Synchro-Tilt Mechanism As Per International Ergonomics Standards Any Position Locking. The Base And Pin Wheels Are Made In The Nylon. 120Mm H Gas Lift Should Be Provided With Tower Bellow , Od31990 / 2023_2024 High Back Chair Made With Feather Foam Seat & Mesh Back With Lumber Support. , The Gas Lift Mechanism Should Be Tested As Per Bifmastandards. The Pedestal Should Be Five Legged Injection Mouldedin Black 30% Glass –Filled Nylon And Fitted With 5 Nos Twin Wheel Castors. The Castors Of The Chairs Should Be Glass Filled, It Should Have Synchro Any Anglelocking Arrangement , Od31991 / 2023_2024Providing And Fixing Trap Doors For Access To The Areas Above False Ceiling. The Trap Door Shall Have An External Frame Made Of Powder Coated Aluminium Channel On Which The Shutter Is Hinged. Shutter Shall Be Made 3 Mm Thick Acp Sheet Shutter External Frame Of Shutter Made Of Powder Coated Aluminium Channel. Concealed Heavy Duty Hinges Shall Be Used To Mount The Shutters And Locking Shall Be Provided. The Shutter Shall Be Moulded In Level With The False Ceiling Forming A Groove All Around. Sufficient Number Of Hinges And Locks Shall Be Provided To Avoid Sagging Of The Shutter. Key Also Shall Be Supplied. No Extra Rate Shall Be Provided For Suspenders Or Frame Works All Round For Linking The Trap Door To Gyp Board / Any Other False Ceiling. The Rate Including All Labour Charges , Material Charges Ect Complete. , Od33559 / 2023_2024 Supplying And Laying Polyster , Washable And Stainfree Cloth ( Bio-Active Fabric Washable Germfree-Suitable For Icu Room ) Curtain System With Maximum Curtain Cloth Height 230Cm ( Top 30 Cm White Colour Net And 200Cm Light Blue Colour As Per Approval ) Stitching With Stifiner Tape, Pleats, Ironing And Laying In Icu Room Around Each Bed Using Pvc Runner With Hooks&Stopper For Hanging / Sliding Etc. As Per The Direction Of Engineer In Charge Including Conveyance To Site , Laying In Line And Level , Sealing All Cuttings In False Ceiling With Powder Coated Ms Cup , All Leads And Lifts Including All Labour Charges Etc. Complete. ( Unpleated Length Of The Cloth Maesurement Will Be Considered For Payment Also The Bottom And Top Foldings Will Not Be Considered In Cloth Measuremnet ) / Supplying And Fixing Powder Coated 20Mm Dia. Gi Round Tube Hanging Support Of Required Length ( App. Length 1.10M ) One End Fixing From Slab By Using 6Mm Dia. Expansion Bolt At A Distance Not More Than 2 M, C / C Down End Fixed To Powder Coated Aluminium Channel Frame 45X20mm X1mm Thick Section By Using Ss Screw As Per The Direction Of Engineer In Charge Including Conveyance To Site, Laying In Line And Level , Sealing All Gaps In False Ceiling Due To Hanging Supports , All Leads And Lifts, Including All Labour Charges Etc. Complete. , Od33560 / 2023_2024 Providing And Fixing Vertical Blinds As Per The Direction Of Engineer In Charge , Furniture& Other Works: Lead Lined Door Shutters: 2Mm Lead Lined Door Shutterswithsolid Cored ( 30Mm ) Lead ( 2Mm ) Lined Flush Door Side Hung Two Rebated Shutters With Plywood ( 6Mm ) & Laminated ( 1Mm ) On Both Sides And All Accessories ( Ss Hinges ( 4 Nos ) , Tower Bolt , Ss Handles Etc.. ) , Lead Lined Door Frames: Lead ( 2Mm ) Lined Flush Door Side Hung Single Shutter With Plywood ( 6Mm ) &Laminated ( 1Mm ) On Both Sides And All Accessories ( Lead Sheet Should Overlap Door Frame & Wall ) Includingproviding Wood Work In Frames Of Doors And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length , Using Good Quality Anjili Wood / Jack Wood ( Frame Size 12 Cm X 8 Cm ) , Wood Frame For Fixing Lead Glass ( Lead Sheet Should Overlap Door Frame & Wall ) , Steel Cupboard ( Godrej ) For Storage 6Ft Tall 3 Feet Width , Cupboardfor Storage Of Catheters , 6Ft Tall 3 Feet Width.19 Mm Ply Board Construction Laminate Finishpainted ( Enamel ) As Per Approval. Front Panels To Have A Locking Arrangements With One Panel Having Tower Bolt On The Inner Sidewith Handles , Magnetic Hinges Andall Complete , Providing, Fixing And Installation Of Floor Mounted 2 Bay Scrub Station Made Of Ss 304 1.6Mm Thk. Sheet Withtimeout Facilities, Foot Operated With Hot And Cold Water Mixture Complete With All Fittings Etc. Satin Finish And Most Optimal Ra Value. Elbow Operated Water And Hand Scrub. Curved Joints To Avoid Microbial Deposition And Growth, Ensuring Perfect Hygiene And Ease Of Cleaning. The Station Shall Be Equipped With Soap Dispensers. Easily Openable For Refilling The Hand Scrub / Routine Maintenance. Two Bay 63”X29”44” , Catheter Hanger And Wall Clamp Ss304 For 5 Aprons Including All Materials And Fittings , Lead Apron Hanger. Completely Made Of Ss304. Provision To Hang 10 Aprons. The Hanger Should Be 2Ft Width. Shoould Have Strong Base For Stability. The Width Of The Total Assembly Shall Be 3.5Ft Width And 2 Ft Depth. The Height Shall Be 153 Ft. , Providing And Fixing 2.0Mm Th. Vinyl Floor With Rubber Based Adhesive Over Clean And Smooth Surface Including Finishing By Rolling A Light Roller All Complete. , Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. , Supplying And Fixing Call Bell / Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group B , Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. Group C , Wiring For Circuit / Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire , Wiring For Circuit / Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X 2.5 Sq. Mm + 1 X 2.5Sq. Mm Earth Wire , Wiring For Circuit / Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2 X 4 Sq. Mm + 1 X 4Sq. Mm Earth Wire , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.4 X 6 Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 3 X 1.5 Sq.Mm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.3 X 2.5Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 3 X 4 Sq. Mmm , Supplying And Drawing Following Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor, Unarmored Telephone Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.2 Pairs , Supplying And Drawing Co-Axial Tv Cable Rg-6 Grade, 0.7 Mm Solid Copper Conductor Pe Insulated, Shielded With Fine Tinned Copper Braid And Protected With Pvc Sheath In The Existing Surface / Recessed Steel / Pvc Conduit As Required. , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25Mm , Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required1 Run Of Cable , Cat 6 Rj 45 Computer Jack Modular Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5 / 6 Amp Switch , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 2 Way 5 / 6 Amp Switch , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15 / 16 Amp Switch , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5 / 6 Amp Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15 / 16 Amp Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Telephone Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Tv Antenna Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.Bell Push , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. , Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 1 Or 2 Module ( 75Mmx75mm ) , Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 3 Module ( 100Mmx75mm ) , Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 6 Module ( 200Mmx75mm ) , Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 8 Module ( 125Mmx125mm ) , Supplying And Fixing Call Bell / Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Extra For Fixing The Louvers / Shutters Complete With Frame For An Exhaust Fan Of All Sizes , Charges For Cutting Holes Suitable For Accommodating Exhaust Fans Up To 305Mm Sweep Including Plastering Color Washing Etc. As Required. , Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage Connection Testing, Commissioning Etc. As Required.Upto 450 Mm Sweep , Supply Of 300 / 305 Mm Sweep Light Duty Exhaust Fan In Metal Frame Working On230 Va / C , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required4 Way ( 8+12 ) - Three Phase Double Cover ( Ip 42 / 43 ) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required6 Way ( 8+18 ) - Three Phase Double Cover ( Ip 42 / 43 ) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 4 Way ( 8+12 ) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp / Tp Mcb As Outgoing ( Ip 42 / 43 ) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 6 Way ( 8 + 18 ) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp / Tp Mcb As Outgoing ( Ip 42 / 43 ) , Supplying And Fixing Following Way Prewired Sp&N Mcb Distribution Board Of Steel Sheet For 240 Volts On Surface / Recess Complete With Loose Wire Box, Terminal Connectors For All Incoming And Outgoing Circuits, Duly Prewired With Suitable Size Fr Pvc Insulated Copper Conductor Up To Terminal Blocks, Tinned Copper Bus Bar, Neutral Link, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 2+12 Way, Double Door , Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps , Supplying And Fixing Following Rating, Four Pole, ( Three Phaseand Neutral ) , 415 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Dbcomplete With Connections, Testing And Commissioning Etc. Asrequired. 63 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, ( Three Phase And Neutral ) , 415 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Amps , Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole , Supplying And Fixing Following Rating, Three Pole, Mcb63 A Rating, 3 Pole, Mcb , Supplying And Fixing Following Rating, Three Pole, Mcb 40 A Rating, 3 Pole, Mcb , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required100 Amp, 30 Ka 4 Pole , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required125amp, 36Ka , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Existing Panel Assembly As Required. 16A -100A, 35 / 36 Ka ( Ics=100%Icu ) , 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Cable Tray As Required. Above 35 Sq. Mm And Upto 95 Sq. Mm ( Clamped With 25X3mm Ms Flat Clamp ) , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 185 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 240 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 25 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 50 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 10 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 16 Sq Mm With Factory Made Clamp , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required.3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 70 Sq Mm , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armoured Aluminum Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required.3.5 Core 70 Sq Mm , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required.225Mm Width X 50Mm Depth X 1.6Mm Thickness , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays Bends With Perforation Not More Than 17.5%, , Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etcas Required 225 Mm Width X50 Mm Depth X 1.6 Mm Thickness , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required. 50 Sqmm , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 3 1 / 2X 70 Sq. Mm ( 38Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1 / 2X 95 Sq. Mm ( 45Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1 / 2X 185 Sq. Mm ( 57Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1 / 2X 240 Sq. Mm ( 62Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.4 X 10 Sq. Mm ( 25Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.4 X 16 Sq. Mm ( 28Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 25 Sq. Mm ( 28Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 50 Sq. Mm ( 35Mm ) , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required. 16 Sq.M , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required.25 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required.10 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 50 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.25 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.16 Sq.M , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.10 Sqmm , Supplying And Providing Earth Clamps For Siemens / Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required.25Sq - 95Sq Mm With 20 Mm Wide X 1.20 Mm Thick Clip , Supplying And Providing Earth Clamps For Siemens / Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required. 4Sqmm-16 Sq Mm With 12 Mm Wide X 1 Mm Thick Clip , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required2.65 Mm Copper Conductor ( 12 Swg ) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg ) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required4.00 Mm Copper Conductor ( 8 Swg ) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.2.65 Mm ( 12 Swg ) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 3.15 Mm ( 10 Swg ) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 4.00 Mm ( 8 Swg ) , Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal / Coke And Salt As Required. , Supply And Clamping The Following Size Of Strips On Surface Of Wall / Parapet / Existing Cable Tray Using Clamps Fabricated From 20 X 3 Mm Gi Flat Duly Painted Or Heavy Duty Gi Spacer Saddles Spacing Of Clamps Not Exceeding 1 M, Making Good The Damages, Color Washing Etc. As Required ( For Horizontal Run ) 25 X 3 Mm Copper Strip , Supplying, Threading, Laying And Jointing Of The Following Sizes Of B Class Gi Pipe With All Required Accessories In Ground In Trench As Protective Covering To Earth Leads40mm Dia , Supplying And Laying 25 Mm X 5 Mm Copper Strip At 0.50 Meter Below Ground As Strip Earth Electrode, Including Connection / Terminating With Nut, Bolt, Spring, Washer Etc. As Required. ( Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt & Spring Washer Spaced At 50Mm ) , Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required2.00 Mm Copper Conductor ( 14 Swg ) , Supply Conveyance, Installation, Testing And Commissioning The Light Fittings Of Following Types Made From Crca Sheet 0.5Mm Thickness With All Accessories And Lamps Directly On Wall And Giving Connections With 16 / 0.20 Mm 3 Core Pvc Insulated And Sheathed Round Copper Conductor Flex Wire Or Extending The Original Wiring And Giving Connections As Required 1200 Mm 1X20w Led Lamp With Box Type Fixture , Supply & Installation Of Light Fittings On Tw Round Block
Supply, Conveyance Installation Testing And Commissioning The Light Fittings Of Following Types Made Of Crca With 0.5Mm Thickness Complete With All Accessories And Lamps Etc. Directly On Wall Or Ceiling With Pvc Round Block Neatly Painted To Suit The Fitting And Giving Connection With Required Length Of 16 / 0.20Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss And Giving Connections As Required.1200Mm 1X20w Led Lamp With Box Type Fixture , Recess Mounted Led Luminaire With Full Diffuser Type Upto 36 W ( Max ) , 2X2 Led, Cool White, 5700K, White Powder Coated Crca Housing, Wipro Crco10r038hp57gl1 Or Bajaj Bzrsql 36W Gzi Cw Or Equivalent , Frame For Fixing Recess Mounted Led 2X2 Ft Luminaire 608 Mm X 608 Mm , Recess Mounted Circular Led Retrofit Downlighter, 15W, Powder Coated White Finish, Bpslr 15W Wh Bajaj Or Equivalent , Supplying And Fixing Of 6 / 7 W Pin Type Led Bulb In The Existing Angle Batten Etc As Required ( Philips, Wipro Or Similar Superior Make ) , Sitc Of 400Mm Sweep Meduim Duty Wall Fans With Metallic Vanes ( Make: M / S Almonard / Crompton / Bajaj Or Equivalent ) , Abc Powder Type Fire Extinguisher With Nabl Approval, Fights Class A, B, C And Electrically Started Fires. , Fire Extinguisher Carbon Di-Oxide Type With Nabl Approval , Charges For Dismantling The Existing Electrical Installations Complete Making Good The Damages Of The Wall And Conveying The Dismantled Materials To Store Etc As Required. , Numbering Of Ceiling Fan / Exhaust Fan / Fluorescent Fittings As Required. , Copper Pipe With Superlon Insulation For Suction And Discharge , Pvc Drain Pipe With Proper Insulation , Weather Proof 3 Core Copper Wire For Indoor To Outdoor Connecting Cable ( Size As Per The Requirement Of Ac Manufacturer ) , Core Cutting Charges Including Making The Surface Finished With Plastering And Painting, Making Good And Finishing With Matching Surface After Housing Pipe Etc. , Supporting Stand For Fixing Outdoor Unit ( Powder Coated ) , 4 Kva Voltage Stabilizer Wall Mount Type With Time Delay, High& Low Voltage& Thermal Overload Protection, Input Voltage: 170-220V, Output Voltage : 200-240V, High Voltage Cut Off : 240V, Efficiency: >95%, Frequency : 50Hz, V Guard Vg 500 Or Equivalent , Supply, Conveyance Testing And Commissioning Of 2 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar / Lg ( Dual Inverter Type ) / Voltas / Mitsubishi Or Superior Superior Brands, Cooling Capacity 6000 Kw / Hr With Rotary / Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500 / 450, Led / Lcd Display , Supply, Conveyance Testing And Commissioning Of 1 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar / Lg ( Dual Inverter Type ) / Voltas / Mitsubishi Or Superior Brands, Cooling Capacity 3000 Kw / Hr With Rotary / Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500 / 450, Led / Lcd Display , Sitc Of 19 Mm Thick Nitrile Rubber For Under Deckinsulation , Charges For Cutting Holes Suitable For Accommodating The Supply Ducts Including Plastering, Color Washing Etc. As Required. , Outdoor Unit Stand With Ribbed Rubber Pads , Electrical Cabling Between Indoor And Outdoor Units, With Required Size Cables / Wires ( Havells / Rr Kabel / V-Guard Frls Wires ) , Supply, Installation, Testing And Commissioning Upvc Drain Pipe 6Kg / Sq.Cmof Suitable Dia Connecting The Drain Pan Of The Indoor Units To Nearest Drain Point, With 12Mm Thick Closed Cell Elastomeric Insulation As Per Specification , Motorized Volume Control Damper For Individual Operation Of Ductable Split Air Conditioners , Supply And Fixing Of Canvas Connection And Ribbed Rubber Pads As Vibration Isolators , Providing And Fixing Of Thermal Insulation Lining With 13Mm Thick Nitrile Rubber Closed Cell Type With Adhesive, On Supply Duct. , Providing And Fixing Of Acoustic Duct Lining With 10Mm Thick Nitrile Rubber Open Cell Type Inside The Ducts , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminum Continuous Grilles 150Mm High For Return Air As Per Spec , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminimum Continuous Grilles 150 Mm High For Supply Air With Aluminum Damper As Per Spec , Supply, Installation, Testing And Commissioning Of Volume Control Duct Damper Made Of Extruded Aluminum For Ducts / Collars To Be Provided With Suitable Links, Lebers And Quadrants For Manual Control Of Volume Of Air Flow And For Proper Balancing Of The Air Distribution In The Main Duct Complete With Neoprene Rubber Gaskets, Nuts, Bolts, Screws Linkages, Flanges Etc., As Per Specifications. , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges , Supports, Gi Rods , Anchor Bolts , Gi Nuts And Bolts, Pvc / Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof / Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 24G , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges , Supports, Gi Rods , Anchor Bolts , Gi Nuts And Bolts, Pvc / Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof / Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 22G , Supply, Installation, Testing And Commissioning ( Sitc ) Of 11 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu / Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring ( Max 3M From Isolator ) And Control Cabling ( Indoor To Outdoor ) , Thermostat Wiring, High-Low Pressure Cut Out, Suitable For Three Phase 440V Supply Etc Complete As Required , Supply And Providing Copper Earth Bus In The Panel Board , Cardiac Catheter Wash Station : Completely Made Ofss 304 Gsatin Finish, All Curved Joints Should Be As Perhtm Standards To Ensureperfect Hygiene And Ease Of Cleaning, Provision Forconnecting The Catheter Using 3 Way Adapter, Provision To Connect Air ( High Pressure ) And Water Through Separate Discharge Pipe Lines To Clean The Catheter, Wall Mounted Type, Approximate Dimension 33”Lx 24”W X 57”H, Provisions To Connect And Clean At Least 6 Catheters Simultaneously. , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall / Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalised, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Busbars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel ( Required For Short Circuit Rating, Temperature Rise And Ip Classification ) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb ( 0-500 ) V Class 1 With 90 Deg Defl. Scale. ( 0-200 ) A Class 1 With 90 Deg Defl. Scale Voltmeter Selector Switch 200 / 5 A 5 Va Class .5S Cts On / Off Indication Lamp Digital Multifunction Meter To Read V, A.Hz, Pf, Kwh Surge Protection Device ( Type1+2 ) Incomer 400A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 200A Copper Tpn Busbar Chamber With Copper Busbar Out Goings 250A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 160A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 100 A Fp Mccb Isolator-2Nos 63 A Fp Mccb Isolator-2Nos The Panel Shall Be Top Entry / Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Panel Assembly Made Out Of 1.6Mm Crca Powder Coated Sheet As Required. 320A / 400A, 50 / 55 Ka ( Ics=100%Icu ) , 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall / Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel ( Required For Short Circuit Rating, Temperature Rise And Ip Classification ) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. 4A Sp Mcb ( 0-500 ) V Class 1 With 90 Deg Defl. Scale. ( 0-200 ) A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200 / 5 A 5 Va Class .5S Cts On / Off Indication Lamp, Digital Multi-Function Meter To Read V, A.Hz, Pf, Kwh Incomer 250A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 250A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 200 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 1 Nos. 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 2 Nos. 63 A Fp Molded Case Circuit Breaker - 2 Nos.The Panel Shall Be Top Entry / Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification , Suitable De- Humidifier Units : Extraction At Least 35 Litres / Day, Compresor : Rotary, Air Flow : At Least 220M3 / Hr, Reputed Brand, Input 230Vac , Charges For Obtaining Electrical Inspectorates Approval Including Scheme Apporval And Final Approval And Regularizing With Kseb , 24-Port Gigabit Manageable Smart Network Switch With 2 Sfps. Rack Mountable , Patch Panel - 24-Port Patch Panel With Cable Tray. Rack Mountable , 4U Rack- Wall Mountable Including 4X 6Amp Power Distribution Box , Supply Of Branded 1Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 2Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 3Mtr Patch Cords With Cat 6 Cable. , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall / Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel ( Required For Short Circuit Rating, Temperature Rise And Ip Classification ) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb ( 0-500 ) V Class 1 With 90 Deg Defl. Scale ( 0-200 ) A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200 / 5 A 5 Va Class .5S Cts On / Off Indication Lamp, Digital Multi-Function Meter To Read V, A.Hz, Pf, Kwh, Incomer 200A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos Out Goings 160 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 2 Nos 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 2 Nos.The Panel Shall Be Top Entry / Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specifications.Pn Busbar Chamber With Copper Busbar. ( Nottaken For Evaluation ) , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall / Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel ( Required For Short Circuit Rating, Temperature Rise And Ip Classification ) And With Following Switch Gears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type Digital Multi-Function Meter To Read V, A.Hz, Pf, Kwh Incomer 160A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 160A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 125A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 1 Nos %Icu= 25Ka ) - 2 Nos 63A Fp Mccb - 3 Nos The Panel Shall Be Top Entry / Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification. ( Not Taken For Evaluation ) , Supply, Installation, Testing And Commissioning ( Sitc ) Of 8.75 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu / Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring ( Max 3M From Isolator ) And Control Cabling ( Indoor To Outdoor ) , Thermostat Wiring, High-Low Pressure Cut Out, Suitable For Three Phase 440V Supply Etc Complete As Required ( Not Taken For Evaluation ) , The Scrub Station Shall Be Made Of High-Grade Stainless Steel 304 With Stain Polish Finish And Wired To The Current Iee Regulations & Bs 7971. The Scrub Stations Control System Shall Be Based On Advanced Microprocessor. The Scrub Station Shall Be Sensor-Activated 24Vac. The Scrub Station Shall Be Provided With User Selectable Time Out Control. The Supply Shall Not Be Interrupted In Case Of Power Failure Or Maintenance. The Station Shall Be Equipped With Thermostatic Mixing Valve To Controls The Temperature Of Hot / Cold Water Supply. The Washing Faucet Shall Be Made Of Chrome Plated Brass Hand. The Station Shall Be Equipped With Soap Dispensers. Two Bay 63”X24”31” ( Not Taken For Evaluation ) , Eto Sterlizer, Sealing Machine & Accessories ( Not Taken For Evaluation ) , Latest Dose Reduction / Image Quality Improvement Packageslike Autoright / Clarity / Optiq. ( Not Taken For Evaluation ) , Cathlab Machine As Per Specifications With 18 Inches Or 46Cms Diagnol Detector Except Monitors ( All Configuration As Per Sr No 13 Except Detector ) ( Not Taken For Evaluation ) , Iabp As Per The Specification ( Not Taken For Evaluation )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
19.
Health and Family Welfare #10267202 Price Bid
Supply of Cardiac Cath Lab With Ep Facility Model B , Cathlab Machine As Per The Specification Except The Following , Medical Grade Large High Definition Fhd Display 55 , Four Medical Grade High Definition Display Lcd / Led Flat 19 Or Higher Monitors With Wide Viewing Angle, High Luminance High Contrast, Flicker Free, Distortion Free , Electrophysiology Application , Workstation As Per Spec , High Pressure Injector With 200 Syringes , Online Ups For Cathlab & Accessories , Console, Workstation, Lights And Computer , All In One Computer With Laser Printer , 12 Channel Ecg With Pc Connectivity , Full Wrap Around Lead Aprons , Skirt ( With Fastening Belt ) -Vest Type Lead Aprons , Front Fulltype Lead Apron , Light Weight Leadless Single Piece Aprons With Front And Back Coverage , Light Weight Leadless Skirt And Vest With Fastening Belt , Thyroid Guard Lead Less , Leadless Head Gear Radiation Protection And Light Weight Lead Goggles , Lead Stockings , Lead Spectacles , Lead Gloves , Heavy Duty Stand With Hangers To Hold Atleast 5 Lead Aprons ( Stainless Steel 304 Construction ) , Wall Mounted Hangers To Hold Atleast 5Lead Aprons , Intercom Between Exam And Control Room , Instrument Table , Accessory Table , Buy Back Offer Of Existing Cathlab Model Philips Allua Fd10 Installed At Mch Kottayam , 15.3 Demolishing R.C.C. Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material With In 50 Metres Lead As Per Direction Of Engineer -In-Charge. , 15.7.4 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar , 15.12.1 Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below , 15.12.2Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead: Of Area Beyond 3 Sq. Metre , 15.23.1Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm , 15.57 Dismantling Aluminium / Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Surplus Material And Stacking Of Serviceable Material With In 50 Metres Lead As Directed By Engineer - In-Charge , 2.34.1Supplying Chemical Emulsion In Sealed Containers Including Delivery As Specified.Chlorpyriphos / Lindane Emulsifiable Concentrate Of 20% , 2.35.1.1Diluting And Injecting Chemical Emulsion For Post -Constructional Anti-Termite Treatment ( Excluding The Cost Of Chemical Emulsion ) :Along External Wall Where The Apron Is Not Provided Using Chemical Emulsion @ 7.5 Litres / Sqm Of The Vertical Surface Of The Substructure To A Depth Of 300Mm Including Excavation Channel Along The Wall & Rodding Etc. Complete: With Chlorpyriphos / Lindane E.C. 20% With 1% Concentration , 24.2Providing And Fixing Double Scaffolding System ( Cup Lock Type ) On The Exterior Side Of Building / Structure, Upto 25 Metre Height, Above Ground Level, Including Additional Rows Of Scaffolding In Stepped Manner As Per Requirement Of Site, Made With 40 Mm Dia M.S. Tube, Placed 1.5 Metre Centre To Centre, Horizontal & Vertical Tubes Joint With Cup & Lock System With M.S. Tubes, M.S. Tube Chakkus, M.S. Clamps And Staircase System In The Scaffolding For Working Platform Etc. And Maintaining It In A Serviceable Condition For Execution Of Work Of Cleaning And / Or Pointing And / Or Applying Chemical And Removing It Thereafter. The Scaffolding System Shall Be Stiffened With Bracings, Runners, Connecting With The Building Etc, Wherever Required, If Feasible, For Inspection Of Work At Required Locations With Essential Safety Features For The Workmen Etc., Complete As Per Directions And Approval Of Engineer-In-Charge. Note: - ( 1 ) The Evaluational Area Of The Scaffolding Shall Be Measured For Payment Purpose, ( 2 ) The Payment Will Be Made Once Only For Execution Of All Items Of Such Works. , 15.60 Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved , 50.2.25.1 Filling With Contractors Own Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M As Per Direction Of Site Engineer-In-Charge , 50.4.1.1 Providing And Laying In Position Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size ) Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing For Leveling Coarse Of Floor And Roof Etc. , 50.5.5Reinforced Cement Concrete Work In Arches, Archribs, Domes, Vaults, Shells, Folded Plate And Roof Having Slope More Than 15 Degree Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand: 3 Graded Stone Aggregate 20 Mm Nominal Size ) . , 50.5.33.2 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-20 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. Note:- Cement Content Considered In This Item Is @ 330 Kg / Cum. Excess Or Less Cement Used As Per Design Mix Is Payable Or Recoverable Separately. All Work Above Plinth Level Upto Floor V Level , 5.22.1 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelmild Steel And Medium Tensile Steel Bars , 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform , 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil , 6.26.2Brick Work With Common Burnt Clay Selected F.P.S ( Non Modular ) Bricks Of Class Designation 7.5 In Exposed Brick Work Including Making Horizontal And Vertical Grooves 10 Mm Wide 12 Mm Deep Complete In Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) Above Plinth Level And Upto Floor V Level , 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks ( Factory Made ) Of Size 40X20x20cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand ) Etc Complete. , 50.6.1.8 Solid Block Masonry Using Pre Cast Solid Blocks ( Factory Made ) Of Size 40X20x15cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In: Cm 1:6 ( 1 Cement : 6 Coarse Sand Etc Complete , 50.6.3.2 Solid Block Masonry Using Pre Cast Solid Blocks ( Factory Made ) Of Size 40X20x10 Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level For 10 Cm Thick Wall In : Cm 1:6 ( 1 Cement : 6 Coarse Sand ) Including Cost Of Scaffolding Complete , 13.1.1Cement Plaster12 Mmof Mix: 1:4 ( 1 Cement : 4 Fine Sand ) , 13.7.1Cement Plaster 12 Mmfinished With A Floating Coat Of Neat Cement Of Mix: 1:3 ( 1 Cement : 3 Fine Sand ) , 11.37Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm ( Thickness To Be Specified By The Manufacturer ) , Of 1St Quality Conforming To Is : 15622, Of Approved Make, In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. , 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. , 11.41.3 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 800X 800 Mm , Od31976 / 2023_2024Providing And Fixing First Quality Vitrified Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , 11.48.2 Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade ( 0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg ) . Including Filling / Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge. Size Of Tile 600X600 Mm , 11.48.3Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade ( 0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg ) . Including Filling / Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge.Size Of Tile 800X800mm , 11.55.1 Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm ( Average ) Thick Base Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge :Flamed Finish Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , 50.9.1.1Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length ( Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately ) , Using Good Quality Anjili Wood / Jack Wood , 50.9.2.1Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineerin - Charge. Using Anjili / Jack Wood , 21.1.1.2 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) : For Fixed Portionpowder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) , 21.1.2.2 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately ) Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge.Pre- Laminated Particle Board With Decorative Lamination On Both Sides , Od31977 / 2023_2024 Supplying And Fixing Flush Door Shutter, Shutter Of Required Size, Thickness 30Mm Thick, Finished With 1 Mm Laminate Of Approved Shade With 9 X 16 Clear Glass Vision Panels As Per Design Including Necessary Hinges , Od31978 / 2023_2024 Frosted Film - Supply And Installation Of 3M Make Frosted Film Pattern Throughout All The Internal Glass Panels Wherever Required Of Approx. 1.5 M Height As Per The Approved Pattern. , Od31979 / 2023_2024 Providing And Fixing Extruded Section Body Tubular Type Universal Hydraulic Door Closer ( Having Brand Logo With Is: 3564, Embossed On The Body, Door Weight Upto 36 Kg To 80 Kg And Door Width From 701 Mm To 1000 Mm ) , With Double Speed Adjustment With Necessary Accessories And Screws Etc. Complete , Od31980 / 2023_2024 Providing And Fixing 4.00 Mm Thick Acp Sheet For Cupboard Including All Cost, Conveyance, Labour Charges Etc Complete , 21.3.1 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) : With Float Glass Panes Of 4.0 Mm Thickness , 12.45.2 Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms / Sqm ( Both Side Inclusive ) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37 Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50 Mm Long With 6 Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall / Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25 Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5X25 Mm At 230 Mm C / C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound, Jointing Tapes, Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With: 12.5 Mm Thick Tapered Edge Gypsum Fire Resistant Board Conforming To Is; 2095-Part I , 12.54.1 Providing And Fixing Gi Clip In Metal Ceiling System Of 600X600 Mm Module Which Includes Providing And Fixing C Wall Angle Of Size 20X30x20 Mm Made Of 0.5 Mm Thick Pre Painted Steel Along The Perimeter Of The Room With Help Of Nylon Sleeves And Wooden Screws At 300 Mm Center To Centre, Suspending The Main C Carrier Of Size 10X38x10 Mm Made Of G.I Steel 0.7 Mm Thick From The Soffit With Help Of Soffit Cleat 37X27x25x1.6 Mm, Rawl Plugs Of Sixe38x12 Mm And C Carrier Suspension Clip And Main Carrier Bracket At 1000 Mm C / C. Inverted Triangle Shaped Spring Tee Having Height Of 24 Mm And Width Of 34 Mm Made Of Gi Steel 0.45 Mm Thick Is Then Fixed To The Main C Carrier And In Direction Perpendicular To It At 600 Mm Centers With Help Of Suspension Brackets. Wherever The Main C Carrier And Spring T Have To Join, C Carrier And Spring T Connectors Have To Be Used. All Sections To Be Galvanized @ 120 Gms / Sqm ( Both Side Inclusive ) , Fixing With Clip In Tiles Into Spring T With :Gi Metal Ceiling Clip In Plain Beveled Edge Global White Color Tiles Of Size 600X600 And 0.5Mm Thick With 25 Mm Height, , Made Of G.I Sheet Having Galvanizing Of 100 Gms / Sqm ( Both Sides Inclusive ) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns ( Minimum ) , Including Factory Painted After Bending . , 12.58.1 Providing And Fixing Tiled False Ceiling Of Approved Materials Of Size 595X595 Mm In True Horizontal Level, Suspended On Interlocking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanized @ 120 Grams / Sqm, Both Side Inclusive ) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick ( Minimum ) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet, 1200 Mm Long Space Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel To Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting / Making, Opening Of Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Of Size 27 X 37 X 25 X 1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gi Adjustable Rods With Galvanized Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. 8Mm Thick Fully Perforated Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Autoclaving Process To Give Stable Crystalline Structure With Minimum Compressive Strength 225 Kg / Sq. Cm, Bending Strength 100 Kg / Sq. Cm, Of Size 595X595 Mm, Having Perforation Of Dia, 10 Mm With Minimum Perforated Area 18% With Non Woven Tissue On The Back Side, Having An Nrc ( Noise Reduction Coefficient ) Of 0.85, With 50 Mm Thick Rockwool Of 48 Kg / Cum Backing. , 21.4.2Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is: 6315, Having Brand Logo Embossed On The Body / Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors, Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Engineer -In- Charge.With Brass Cover Plate Minimum 1.25 Mm Thickness , 21.13 Providing And Fixing 100 Mm Brass Locks ( Best Make Of Approved Quality ) For Aluminium Doors Including Necessary Cutting And Making Good Etc. Complete , 50.9.11.1Providing And Fixing Thomson Multi Wood Board Or Equivalent Make Paneling 12 Mm Thick, To Frame, Backing Or Studding With Screws Etc. Complete ( Frames, Backing Or Studding To Be Paid Separately ) As Per The Direction Of Site Engineer-In-Charge. , 50.9.12.1 Providing And Fixing Thomson Multi Wood Board Or Equivalent Make, In Shelves With Screws And Fittings Wherever Required, Edges To Be Painted With Polyurethane Primer ( Fittings To Be Paid Separately ) As Per The Direction Of Site Engineer-In-Charge. , 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work , 13.69.1 Polishing On Wood Work With Ready Mixed Wax Polish Of Approved Brand And Manufacture: New Work , 13.80Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , 13.83.2Wall Painting With Premium Acrylic Emulsion Paint Of Interior Grade, Having Voc ( Volatile Including Applying Additional Coats Wherever Required To Achieve Even Shade And Colour.Two Coats , 13.47.1Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work ( Two Or More Coats Applied @ 1.43 Ltr / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) , 10.16.3 Steel Work In Built Up Tubular ( Round, Square Or Rectangular Hollow Tubes Etc. ) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Electric Resistance Or Induction Butt Welded Tubes , Od31981 / 2023_2024Roofing Sheet With Sandwich Puf Roof Panel With 0.40 Mm Or Nearest Size Pre Painted Galvalume Sheet At Top & Bottom , 30 Mm Or Nearest Size Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete , Od31982 / 2023_2024 Wall Cladding With Sandwich Puf Wall Panel With 0.40 Mm Or Nearest Pre Painted Galvalume Sheet At Top &Bottom , 30 Mm Or Nearest Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete. , Od31983 / 2023_2024 Providing At All Heights, Levels And Locations 0.45 Mm Thick Galvalume Sheet Of Alloy 31500 / 31000 / 40800, Conforming To Is 1254, Is 737, Is 2676. The Sheet Shall Be Fixed Using Self Drilling / Self Tapping Ss Screws Of Size 5.5X65 Mm With Epdm Seal Complete Upto Required Pitch In Horizontal, Vertical Or Curved Surfaces I / C Cutting To Size And Shape Where Required As Per The Direction Of Engineer-In-Charge. The Rate Shall Be Inclusive Of All Screws, Seal, Ridge, Labour, Scaffolding, Machinery For Fixing And Approved Sealant Where Required Etc. But Excluding The Cost Of Purlins, Rafters And Trusses. , 17.2.2 Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , 17.7.1 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps , 50.17.1.2 Supplying And Fixing Cp Towel Rod 45Cm Or Nearest Available Length Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge , 50.17.1.5Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 50.17.1.1 Supplying And Fixing Stainless Steel Soap Dish Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 17.31 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Od33878 / 2023_2024 Supplying And Fixing Stainless Steel Mirror Finished H Type Handles Including Material Cost, Conveyance And Fixing Charges Etc Complete. , 50.18.7.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 15Mm Dia 12Kgf / Cm2 -Internal Work- Exposed On Wall , 50.18.7.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mm Dia 10Kgf / Cm2- Internal Work - Exposed On Wall , 50.18.8.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer- In- Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 15 Mm Pipe 12 Kgf / Cm2 , 50.18.8.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 32 Mm Pipe 10Kgf / Cm2 , 50.18.8.9.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chased And Making Good The Wall Etc. 110 Mm Pipe 6Kgf / Cm2 , 50.18.9.8.2 Providing And Fixing Pvc Pipes Includings Of Pipes With One Step Pvc Solvent Cement, Trenching And Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 75 Mm Dia 4 Kgf / Cm2 , Od31984 / 2023_2024 Providing And Fixing 24 Mm Thick Factory Made Pvc Door Shutters Made Of Styles And Rails Of A Pvc Hollow Section Of Size 59 X 24 Mm And Wall Thickness 2 Mm With Inbuilt Edging On Both Sides. The Styles And Rails Mitered And Joint At The Corners By Means Of M.S. Galvanized / Plastic Brackets Of Size 75 X 220 Mm Having Wall Thickness 1.0 Mm And Stainless Steel Screws. The Styles Of The Shutter Reinforced By Fixing Galvanized M.S. Tube Of Size 20 X 20 Mm And 1 Mm Wall Thickness. The Lock Rail Made Up Of H Section, A Pvc Hollow Section Of Size 100 X 24 Mm And 2 Mm Wall Thickness, Fixed To The Shutter Styles By Means Of Plastic / Galvanized M.S. U Cleats. The Shutter Frame Filled With A Pvc Multi-Chambered Single Panel Of Size Not Less Than 620 Mm, Having Over All Thickness Of 20 Mm And 1 Mm Wall Thickness. The Panels Filled Vertically And Tie Bar At Two Places By Fixing Horizontally 6 Mm Galvanized M.S. Rod And Fastened With Nuts And Washers, Complete As Per Manufacturers Specification And Direction Of Engineer-In-Charge ( For W.C. And Bathroom Door Shutter ) . , Od31985 / 2023_2024 Supplying And Fixing Name Board Of Various Sizes Using Foam Sheet Board Including Lettering As Per The Direction Of Departmental Officers Including Cost, Conveyance And Fixing Charges Etc Complete. 45X14cm Size , Od31986 / 2023_2024 Supplying And Fixing The Name Board Of Size 80 X 30 Using Acp Board With Acrylic Lettering Including Cost, Conveyance And Labour Charges For Lettering And Fixing Etc Complete , Od31987 / 2023_2024 Supplying And Fixing Inaugration Board Using Granite Slab Including Lettering As Per Direction Of Departmental Officers Including Cost Of Granite, Lettering And Fixing Charges Etc Complete. Size: 100X84cm , Supplying And Fixing Skylight Of Size 1.2Mx 1.8M With Designed Acrylic Sheet Including 4 Numbers Led Tube As Per The Direction Of Engineer In Charge , Od31989 / 2023_2024 Computer Chair The Medium Back Adjustable Revolving Chair Made With Mesh Back Within Built Handle In The Nylon Finish, The Back Is Designed Extra Lumber Support. The Seat Have Provided Seat Cover In Pp Made With 12Mm Hot Pressed Ply And Pu Moylded Foam. The Tilting Mechanism Should Be Synchro-Tilt Mechanism As Per International Ergonomics Standards Any Position Locking. The Base And Pin Wheels Are Made In The Nylon. 120Mm H Gas Lift Should Be Provided With Tower Bellow , Od31990 / 2023_2024 High Back Chair Made With Feather Foam Seat & Mesh Back With Lumber Support. , The Gas Lift Mechanism Should Be Tested As Per Bifmastandards. The Pedestal Should Be Five Legged Injection Mouldedin Black 30% Glass –Filled Nylon And Fitted With 5 Nos Twin Wheel Castors. The Castors Of The Chairs Should Be Glass Filled, It Should Have Synchro Any Anglelocking Arrangement , Od31991 / 2023_2024Providing And Fixing Trap Doors For Access To The Areas Above False Ceiling. The Trap Door Shall Have An External Frame Made Of Powder Coated Aluminium Channel On Which The Shutter Is Hinged. Shutter Shall Be Made 3 Mm Thick Acp Sheet Shutter External Frame Of Shutter Made Of Powder Coated Aluminium Channel. Concealed Heavy Duty Hinges Shall Be Used To Mount The Shutters And Locking Shall Be Provided. The Shutter Shall Be Moulded In Level With The False Ceiling Forming A Groove All Around. Sufficient Number Of Hinges And Locks Shall Be Provided To Avoid Sagging Of The Shutter. Key Also Shall Be Supplied. No Extra Rate Shall Be Provided For Suspenders Or Frame Works All Round For Linking The Trap Door To Gyp Board / Any Other False Ceiling. The Rate Including All Labour Charges , Material Charges Ect Complete. , Od33559 / 2023_2024 Supplying And Laying Polyster , Washable And Stainfree Cloth ( Bio-Active Fabric Washable Germfree-Suitable For Icu Room ) Curtain System With Maximum Curtain Cloth Height 230Cm ( Top 30 Cm White Colour Net And 200Cm Light Blue Colour As Per Approval ) Stitching With Stifiner Tape, Pleats, Ironing And Laying In Icu Room Around Each Bed Using Pvc Runner With Hooks&Stopper For Hanging / Sliding Etc. As Per The Direction Of Engineer In Charge Including Conveyance To Site , Laying In Line And Level , Sealing All Cuttings In False Ceiling With Powder Coated Ms Cup , All Leads And Lifts Including All Labour Charges Etc. Complete. ( Unpleated Length Of The Cloth Maesurement Will Be Considered For Payment Also The Bottom And Top Foldings Will Not Be Considered In Cloth Measuremnet ) / Supplying And Fixing Powder Coated 20Mm Dia. Gi Round Tube Hanging Support Of Required Length ( App. Length 1.10M ) One End Fixing From Slab By Using 6Mm Dia. Expansion Bolt At A Distance Not More Than 2 M, C / C Down End Fixed To Powder Coated Aluminium Channel Frame 45X20mm X1mm Thick Section By Using Ss Screw As Per The Direction Of Engineer In Charge Including Conveyance To Site, Laying In Line And Level , Sealing All Gaps In False Ceiling Due To Hanging Supports , All Leads And Lifts, Including All Labour Charges Etc. Complete. , Od33560 / 2023_2024 Providing And Fixing Vertical Blinds As Per The Direction Of Engineer In Charge , Furniture& Other Works: Lead Lined Door Shutters: 2Mm Lead Lined Door Shutterswithsolid Cored ( 30Mm ) Lead ( 2Mm ) Lined Flush Door Side Hung Two Rebated Shutters With Plywood ( 6Mm ) & Laminated ( 1Mm ) On Both Sides And All Accessories ( Ss Hinges ( 4 Nos ) , Tower Bolt , Ss Handles Etc.. ) , Lead Lined Door Frames: Lead ( 2Mm ) Lined Flush Door Side Hung Single Shutter With Plywood ( 6Mm ) &Laminated ( 1Mm ) On Both Sides And All Accessories ( Lead Sheet Should Overlap Door Frame & Wall ) Includingproviding Wood Work In Frames Of Doors And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length , Using Good Quality Anjili Wood / Jack Wood ( Frame Size 12 Cm X 8 Cm ) , Wood Frame For Fixing Lead Glass ( Lead Sheet Should Overlap Door Frame & Wall ) , Steel Cupboard ( Godrej ) For Storage 6Ft Tall 3 Feet Width , Cupboardfor Storage Of Catheters , 6Ft Tall 3 Feet Width.19 Mm Ply Board Construction Laminate Finishpainted ( Enamel ) As Per Approval. Front Panels To Have A Locking Arrangements With One Panel Having Tower Bolt On The Inner Sidewith Handles , Magnetic Hinges Andall Complete , Providing, Fixing And Installation Of Floor Mounted 2 Bay Scrub Station Made Of Ss 304 1.6Mm Thk. Sheet Withtimeout Facilities, Foot Operated With Hot And Cold Water Mixture Complete With All Fittings Etc. Satin Finish And Most Optimal Ra Value. Elbow Operated Water And Hand Scrub. Curved Joints To Avoid Microbial Deposition And Growth, Ensuring Perfect Hygiene And Ease Of Cleaning. The Station Shall Be Equipped With Soap Dispensers. Easily Openable For Refilling The Hand Scrub / Routine Maintenance. Two Bay 63”X29”44” , Catheter Hanger And Wall Clamp Ss304 For 5 Aprons Including All Materials And Fittings , Lead Apron Hanger. Completely Made Of Ss304. Provision To Hang 10 Aprons. The Hanger Should Be 2Ft Width. Shoould Have Strong Base For Stability. The Width Of The Total Assembly Shall Be 3.5Ft Width And 2 Ft Depth. The Height Shall Be 153 Ft. , Providing And Fixing 2.0Mm Th. Vinyl Floor With Rubber Based Adhesive Over Clean And Smooth Surface Including Finishing By Rolling A Light Roller All Complete. , Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. , Supplying And Fixing Call Bell / Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group B , Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. Group C , Wiring For Circuit / Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire , Wiring For Circuit / Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X 2.5 Sq. Mm + 1 X 2.5Sq. Mm Earth Wire , Wiring For Circuit / Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2 X 4 Sq. Mm + 1 X 4Sq. Mm Earth Wire , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.4 X 6 Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 3 X 1.5 Sq.Mm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.3 X 2.5Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 3 X 4 Sq. Mmm , Supplying And Drawing Following Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor, Unarmored Telephone Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.2 Pairs , Supplying And Drawing Co-Axial Tv Cable Rg-6 Grade, 0.7 Mm Solid Copper Conductor Pe Insulated, Shielded With Fine Tinned Copper Braid And Protected With Pvc Sheath In The Existing Surface / Recessed Steel / Pvc Conduit As Required. , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25Mm , Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required1 Run Of Cable , Cat 6 Rj 45 Computer Jack Modular Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5 / 6 Amp Switch , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 2 Way 5 / 6 Amp Switch , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15 / 16 Amp Switch , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5 / 6 Amp Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15 / 16 Amp Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Telephone Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Tv Antenna Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.Bell Push , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. , Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 1 Or 2 Module ( 75Mmx75mm ) , Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 3 Module ( 100Mmx75mm ) , Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 6 Module ( 200Mmx75mm ) , Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 8 Module ( 125Mmx125mm ) , Supplying And Fixing Call Bell / Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Extra For Fixing The Louvers / Shutters Complete With Frame For An Exhaust Fan Of All Sizes , Charges For Cutting Holes Suitable For Accommodating Exhaust Fans Up To 305Mm Sweep Including Plastering Color Washing Etc. As Required. , Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage Connection Testing, Commissioning Etc. As Required.Upto 450 Mm Sweep , Supply Of 300 / 305 Mm Sweep Light Duty Exhaust Fan In Metal Frame Working On230 Va / C , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required4 Way ( 8+12 ) - Three Phase Double Cover ( Ip 42 / 43 ) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required6 Way ( 8+18 ) - Three Phase Double Cover ( Ip 42 / 43 ) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 4 Way ( 8+12 ) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp / Tp Mcb As Outgoing ( Ip 42 / 43 ) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 6 Way ( 8 + 18 ) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp / Tp Mcb As Outgoing ( Ip 42 / 43 ) , Supplying And Fixing Following Way Prewired Sp&N Mcb Distribution Board Of Steel Sheet For 240 Volts On Surface / Recess Complete With Loose Wire Box, Terminal Connectors For All Incoming And Outgoing Circuits, Duly Prewired With Suitable Size Fr Pvc Insulated Copper Conductor Up To Terminal Blocks, Tinned Copper Bus Bar, Neutral Link, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 2+12 Way, Double Door , Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps , Supplying And Fixing Following Rating, Four Pole, ( Three Phaseand Neutral ) , 415 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Dbcomplete With Connections, Testing And Commissioning Etc. Asrequired. 63 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, ( Three Phase And Neutral ) , 415 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Amps , Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole , Supplying And Fixing Following Rating, Three Pole, Mcb63 A Rating, 3 Pole, Mcb , Supplying And Fixing Following Rating, Three Pole, Mcb 40 A Rating, 3 Pole, Mcb , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required100 Amp, 30 Ka 4 Pole , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required125amp, 36Ka , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Existing Panel Assembly As Required. 16A -100A, 35 / 36 Ka ( Ics=100%Icu ) , 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Cable Tray As Required. Above 35 Sq. Mm And Upto 95 Sq. Mm ( Clamped With 25X3mm Ms Flat Clamp ) , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 185 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 240 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 25 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 50 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 10 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 16 Sq Mm With Factory Made Clamp , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required.3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 70 Sq Mm , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armoured Aluminum Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required.3.5 Core 70 Sq Mm , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required.225Mm Width X 50Mm Depth X 1.6Mm Thickness , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays Bends With Perforation Not More Than 17.5%, , Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etcas Required 225 Mm Width X50 Mm Depth X 1.6 Mm Thickness , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required. 50 Sqmm , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 3 1 / 2X 70 Sq. Mm ( 38Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1 / 2X 95 Sq. Mm ( 45Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1 / 2X 185 Sq. Mm ( 57Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1 / 2X 240 Sq. Mm ( 62Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.4 X 10 Sq. Mm ( 25Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.4 X 16 Sq. Mm ( 28Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 25 Sq. Mm ( 28Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 50 Sq. Mm ( 35Mm ) , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required. 16 Sq.M , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required.25 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required.10 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 50 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.25 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.16 Sq.M , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.10 Sqmm , Supplying And Providing Earth Clamps For Siemens / Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required.25Sq - 95Sq Mm With 20 Mm Wide X 1.20 Mm Thick Clip , Supplying And Providing Earth Clamps For Siemens / Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required. 4Sqmm-16 Sq Mm With 12 Mm Wide X 1 Mm Thick Clip , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required2.65 Mm Copper Conductor ( 12 Swg ) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg ) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required4.00 Mm Copper Conductor ( 8 Swg ) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.2.65 Mm ( 12 Swg ) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 3.15 Mm ( 10 Swg ) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 4.00 Mm ( 8 Swg ) , Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal / Coke And Salt As Required. , Supply And Clamping The Following Size Of Strips On Surface Of Wall / Parapet / Existing Cable Tray Using Clamps Fabricated From 20 X 3 Mm Gi Flat Duly Painted Or Heavy Duty Gi Spacer Saddles Spacing Of Clamps Not Exceeding 1 M, Making Good The Damages, Color Washing Etc. As Required ( For Horizontal Run ) 25 X 3 Mm Copper Strip , Supplying, Threading, Laying And Jointing Of The Following Sizes Of B Class Gi Pipe With All Required Accessories In Ground In Trench As Protective Covering To Earth Leads40mm Dia , Supplying And Laying 25 Mm X 5 Mm Copper Strip At 0.50 Meter Below Ground As Strip Earth Electrode, Including Connection / Terminating With Nut, Bolt, Spring, Washer Etc. As Required. ( Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt & Spring Washer Spaced At 50Mm ) , Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required2.00 Mm Copper Conductor ( 14 Swg ) , Supply Conveyance, Installation, Testing And Commissioning The Light Fittings Of Following Types Made From Crca Sheet 0.5Mm Thickness With All Accessories And Lamps Directly On Wall And Giving Connections With 16 / 0.20 Mm 3 Core Pvc Insulated And Sheathed Round Copper Conductor Flex Wire Or Extending The Original Wiring And Giving Connections As Required 1200 Mm 1X20w Led Lamp With Box Type Fixture , Supply & Installation Of Light Fittings On Tw Round Block
Supply, Conveyance Installation Testing And Commissioning The Light Fittings Of Following Types Made Of Crca With 0.5Mm Thickness Complete With All Accessories And Lamps Etc. Directly On Wall Or Ceiling With Pvc Round Block Neatly Painted To Suit The Fitting And Giving Connection With Required Length Of 16 / 0.20Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss And Giving Connections As Required.1200Mm 1X20w Led Lamp With Box Type Fixture , Recess Mounted Led Luminaire With Full Diffuser Type Upto 36 W ( Max ) , 2X2 Led, Cool White, 5700K, White Powder Coated Crca Housing, Wipro Crco10r038hp57gl1 Or Bajaj Bzrsql 36W Gzi Cw Or Equivalent , Frame For Fixing Recess Mounted Led 2X2 Ft Luminaire 608 Mm X 608 Mm , Recess Mounted Circular Led Retrofit Downlighter, 15W, Powder Coated White Finish, Bpslr 15W Wh Bajaj Or Equivalent , Supplying And Fixing Of 6 / 7 W Pin Type Led Bulb In The Existing Angle Batten Etc As Required ( Philips, Wipro Or Similar Superior Make ) , Sitc Of 400Mm Sweep Meduim Duty Wall Fans With Metallic Vanes ( Make: M / S Almonard / Crompton / Bajaj Or Equivalent ) , Abc Powder Type Fire Extinguisher With Nabl Approval, Fights Class A, B, C And Electrically Started Fires. , Fire Extinguisher Carbon Di-Oxide Type With Nabl Approval , Charges For Dismantling The Existing Electrical Installations Complete Making Good The Damages Of The Wall And Conveying The Dismantled Materials To Store Etc As Required. , Numbering Of Ceiling Fan / Exhaust Fan / Fluorescent Fittings As Required. , Copper Pipe With Superlon Insulation For Suction And Discharge , Pvc Drain Pipe With Proper Insulation , Weather Proof 3 Core Copper Wire For Indoor To Outdoor Connecting Cable ( Size As Per The Requirement Of Ac Manufacturer ) , Core Cutting Charges Including Making The Surface Finished With Plastering And Painting, Making Good And Finishing With Matching Surface After Housing Pipe Etc. , Supporting Stand For Fixing Outdoor Unit ( Powder Coated ) , 4 Kva Voltage Stabilizer Wall Mount Type With Time Delay, High& Low Voltage& Thermal Overload Protection, Input Voltage: 170-220V, Output Voltage : 200-240V, High Voltage Cut Off : 240V, Efficiency: >95%, Frequency : 50Hz, V Guard Vg 500 Or Equivalent , Supply, Conveyance Testing And Commissioning Of 2 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar / Lg ( Dual Inverter Type ) / Voltas / Mitsubishi Or Superior Superior Brands, Cooling Capacity 6000 Kw / Hr With Rotary / Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500 / 450, Led / Lcd Display , Supply, Conveyance Testing And Commissioning Of 1 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar / Lg ( Dual Inverter Type ) / Voltas / Mitsubishi Or Superior Brands, Cooling Capacity 3000 Kw / Hr With Rotary / Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500 / 450, Led / Lcd Display , Sitc Of 19 Mm Thick Nitrile Rubber For Under Deckinsulation , Charges For Cutting Holes Suitable For Accommodating The Supply Ducts Including Plastering, Color Washing Etc. As Required. , Outdoor Unit Stand With Ribbed Rubber Pads , Electrical Cabling Between Indoor And Outdoor Units, With Required Size Cables / Wires ( Havells / Rr Kabel / V-Guard Frls Wires ) , Supply, Installation, Testing And Commissioning Upvc Drain Pipe 6Kg / Sq.Cmof Suitable Dia Connecting The Drain Pan Of The Indoor Units To Nearest Drain Point, With 12Mm Thick Closed Cell Elastomeric Insulation As Per Specification , Motorized Volume Control Damper For Individual Operation Of Ductable Split Air Conditioners , Supply And Fixing Of Canvas Connection And Ribbed Rubber Pads As Vibration Isolators , Providing And Fixing Of Thermal Insulation Lining With 13Mm Thick Nitrile Rubber Closed Cell Type With Adhesive, On Supply Duct. , Providing And Fixing Of Acoustic Duct Lining With 10Mm Thick Nitrile Rubber Open Cell Type Inside The Ducts , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminum Continuous Grilles 150Mm High For Return Air As Per Spec , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminimum Continuous Grilles 150 Mm High For Supply Air With Aluminum Damper As Per Spec , Supply, Installation, Testing And Commissioning Of Volume Control Duct Damper Made Of Extruded Aluminum For Ducts / Collars To Be Provided With Suitable Links, Lebers And Quadrants For Manual Control Of Volume Of Air Flow And For Proper Balancing Of The Air Distribution In The Main Duct Complete With Neoprene Rubber Gaskets, Nuts, Bolts, Screws Linkages, Flanges Etc., As Per Specifications. , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges , Supports, Gi Rods , Anchor Bolts , Gi Nuts And Bolts, Pvc / Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof / Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 24G , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges , Supports, Gi Rods , Anchor Bolts , Gi Nuts And Bolts, Pvc / Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof / Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 22G , Supply, Installation, Testing And Commissioning ( Sitc ) Of 11 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu / Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring ( Max 3M From Isolator ) And Control Cabling ( Indoor To Outdoor ) , Thermostat Wiring, High-Low Pressure Cut Out, Suitable For Three Phase 440V Supply Etc Complete As Required , Supply And Providing Copper Earth Bus In The Panel Board , Cardiac Catheter Wash Station : Completely Made Ofss 304 Gsatin Finish, All Curved Joints Should Be As Perhtm Standards To Ensureperfect Hygiene And Ease Of Cleaning, Provision Forconnecting The Catheter Using 3 Way Adapter, Provision To Connect Air ( High Pressure ) And Water Through Separate Discharge Pipe Lines To Clean The Catheter, Wall Mounted Type, Approximate Dimension 33”Lx 24”W X 57”H, Provisions To Connect And Clean At Least 6 Catheters Simultaneously. , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall / Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalised, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Busbars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel ( Required For Short Circuit Rating, Temperature Rise And Ip Classification ) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb ( 0-500 ) V Class 1 With 90 Deg Defl. Scale. ( 0-200 ) A Class 1 With 90 Deg Defl. Scale Voltmeter Selector Switch 200 / 5 A 5 Va Class .5S Cts On / Off Indication Lamp Digital Multifunction Meter To Read V, A.Hz, Pf, Kwh Surge Protection Device ( Type1+2 ) Incomer 400A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 200A Copper Tpn Busbar Chamber With Copper Busbar Out Goings 250A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 160A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 100 A Fp Mccb Isolator-2Nos 63 A Fp Mccb Isolator-2Nos The Panel Shall Be Top Entry / Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Panel Assembly Made Out Of 1.6Mm Crca Powder Coated Sheet As Required. 320A / 400A, 50 / 55 Ka ( Ics=100%Icu ) , 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall / Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel ( Required For Short Circuit Rating, Temperature Rise And Ip Classification ) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. 4A Sp Mcb ( 0-500 ) V Class 1 With 90 Deg Defl. Scale. ( 0-200 ) A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200 / 5 A 5 Va Class .5S Cts On / Off Indication Lamp, Digital Multi-Function Meter To Read V, A.Hz, Pf, Kwh Incomer 250A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 250A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 200 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 1 Nos. 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 2 Nos. 63 A Fp Molded Case Circuit Breaker - 2 Nos.The Panel Shall Be Top Entry / Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification , Suitable De- Humidifier Units : Extraction At Least 35 Litres / Day, Compresor : Rotary, Air Flow : At Least 220M3 / Hr, Reputed Brand, Input 230Vac , Charges For Obtaining Electrical Inspectorates Approval Including Scheme Apporval And Final Approval And Regularizing With Kseb , 24-Port Gigabit Manageable Smart Network Switch With 2 Sfps. Rack Mountable , Patch Panel - 24-Port Patch Panel With Cable Tray. Rack Mountable , 4U Rack- Wall Mountable Including 4X 6Amp Power Distribution Box , Supply Of Branded 1Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 2Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 3Mtr Patch Cords With Cat 6 Cable. , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall / Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel ( Required For Short Circuit Rating, Temperature Rise And Ip Classification ) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb ( 0-500 ) V Class 1 With 90 Deg Defl. Scale ( 0-200 ) A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200 / 5 A 5 Va Class .5S Cts On / Off Indication Lamp, Digital Multi-Function Meter To Read V, A.Hz, Pf, Kwh, Incomer 200A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos Out Goings 160 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 2 Nos 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 2 Nos.The Panel Shall Be Top Entry / Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specifications.Pn Busbar Chamber With Copper Busbar. ( Nottaken For Evaluation ) , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall / Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel ( Required For Short Circuit Rating, Temperature Rise And Ip Classification ) And With Following Switch Gears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type Digital Multi-Function Meter To Read V, A.Hz, Pf, Kwh Incomer 160A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 160A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 125A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 1 Nos %Icu= 25Ka ) - 2 Nos 63A Fp Mccb - 3 Nos The Panel Shall Be Top Entry / Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification. ( Not Taken For Evaluation ) , Supply, Installation, Testing And Commissioning ( Sitc ) Of 8.75 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu / Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring ( Max 3M From Isolator ) And Control Cabling ( Indoor To Outdoor ) , Thermostat Wiring, High-Low Pressure Cut Out, Suitable For Three Phase 440V Supply Etc Complete As Required ( Not Taken For Evaluation ) , The Scrub Station Shall Be Made Of High-Grade Stainless Steel 304 With Stain Polish Finish And Wired To The Current Iee Regulations & Bs 7971. The Scrub Stations Control System Shall Be Based On Advanced Microprocessor. The Scrub Station Shall Be Sensor-Activated 24Vac. The Scrub Station Shall Be Provided With User Selectable Time Out Control. The Supply Shall Not Be Interrupted In Case Of Power Failure Or Maintenance. The Station Shall Be Equipped With Thermostatic Mixing Valve To Controls The Temperature Of Hot / Cold Water Supply. The Washing Faucet Shall Be Made Of Chrome Plated Brass Hand. The Station Shall Be Equipped With Soap Dispensers. Two Bay 63”X24”31” ( Not Taken For Evaluation ) , Eto Sterlizer, Sealing Machine & Accessories ( Not Taken For Evaluation ) , Latest Dose Reduction / Image Quality Improvement Packageslike Autoright / Clarity / Optiq. ( Not Taken For Evaluation ) , Cathlab Machine As Per Specifications With 18 Inches Or 46Cms Diagnol Detector Except Monitors ( All Configuration As Per Sr No 13 Except Detector ) ( Not Taken For Evaluation ) , Iabp As Per The Specification ( Not Taken For Evaluation )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
20.
Educational and Research Institute #10265178 Price Bid
Tender For Clean Room; 1 PARTITION PANELING WORKS Double skin modular wall panel system made of 0.6 mm thick Precoatedsheet on both sides with PUF as infill of density 40 ± 2 kg/m3, Double tongue and groove joints as per standard manufacturing specification.-50 mm thick PPGI/ PPGIWall panel for coloumn 2 PARTITION PANELING WORKS Double skin modular wall panel system made of 0.6 mm thick Precoatedsheet on both sides with PUF as infill of density 40 ± 2 kg/m3, Double tongue and groove joints as per standard manufacturing specification.-100 mm thick PPGI/ PPGIWall panel for coloumn 3 Wall paneling of PPGI/PPGI of 100 mm thick with 40 mm of glass wool panel, Desnity 100Kg.M3, Non combustable, Penling color as per architect choice. With necessary double door of equal size as per site condition. Fittings complete all. Panel of three side with roof necessary duct cut otu with proper seal to be done as per site for sound insulation. 4 Panel Thickness : 100 mm PPGI/PPGI Wall raiser ( 700 width x depth less than 80 mm) 5 WALKABLE CEILING PANELS PPGI/PPGI -Double skin modular clean room walkable ceiling panels made With 0.6 mm Pre coated sheets on both side with PUF as infill of density of 40 ± 2 Kgs/m3. -50 mm thick PPGI/ PPGI CEILING PANELS 6 CLEANROOM DOORS -50mm thick flush frame made of 1.2 mm thick GPSP powder coated sheet, 0.8 mm thick PU powder coated GPSP sheet with HONEY COMB KRAFT PAPER as infill of 46mm thk shutter suitable for 50mm thk frame, including all the accessories like double glazed veiw glass, hardwares like push plate, kick plate, non concealed door closure. SS D handle, SS ball bearing butt hinges, both side key operated lock & key. Concealed drop seal per leaf and concealed flushbolt for double leaf door etc.- Single Leaf Door - Size 1000 x2100 mm 7 Double Leaf door size 1800mm x 2100 mm 8 Double Leaf door size 2000mm x 2100 mm 9 VIEW PANELS -Double glazed view 5 mm toughned glass with flush design, 50 mm thick flush view panel made of 1 mm thick GI frame with PUF as infill in- between the frame. 10 Coving & Corners -Male & Female R-70 Powder coated coving 11 2D / 3D internal powder coated corner coves 12 External 90 degree powder coated coving 13 Bottom Track for panel 14 Silicon sealent for panel to panel joint 15 Supply, installation of Air shower- Microflow make MFD-AS -1200 Model. Inner dimension- 900x1220x1950 (H), Over Dimension of -1800x1320x2200(H), Cabinet, Platform Stainless Steel-304, of 1 person capacity, GI Powder coated with flush double glazing , hardware like door closure, D handle, ball bearing butt hinches door with vision panel, pre filter - flange type of 90% efficiency, pressure drop -6 to 8 mm, Hepa filter Box type, 00.007 % efficiency, pressure drop of 25 mm of W.c, Adjustablke nozzle of 30mm, As per manufacuter specification ,Control motor by DOL starter, doors by electronmahnectic inter locking, Overload protection, thermal relay,Emergency off- Push button. complete all. consider Micro flow 16 Design , supply, providing of ESD MAT flooring of Homogeneous composition with block conductive layer sandwhich between two antistatic layers. Of BS 2050 /1978IS 3462 /1986 Governing specification. Thickness of the materials 2 mm +/-0.1mm( 0.5mm sandwhich conductive layer), Electrical propertie : Surface resistivity 108 -1010ohms/sq. Decay time: Less than 2 seconds. including copper strip below mat to connec the earth bus complete all. with an thermo welding process complete all. 17 Panels as per technical specifications & schematic diagram. 18 Supply, Installation, Testing and Commissioning of Indoor typeLTSwitchboards, Floor mounting type, Bottom/Top entry. Refer enclosed SLD.Enclosure: Compartmentalized Single front CRCA (Cold rolled Cold Annealed sheet steel) Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mmIP class for Indoor/IP55 with weather proof enclosure for outdoor Bus bars: Electrolytic grade conductivity as per standard IS 5082Bus bar Material: As per SLD Bus bar joints: Shrouded/TinnedProtection releases: As per SLD (Adjustable over current & short circuit unless otherwise specified)Ics=Icu for all breakersUtilization category: All MCCB/ACBs shall be Cat: A except ACBs for Ltg & raw power input distribution panel shall be with Cat: FORM 4B Loovers: Busbar chamber shall have louvers with fine mesh insideShade: Epoxy powder coated RAL 7032Design: Modular type Cable entry: As per site conditionBus bar insulation: Aluminum bus bars shall be bare with color coding at the ends/Copper shall be bare with color coding at the ends/For Humidified areas the copper bus bars shall be coated with tin. 19 Note: The Panel shall be fully as per the requirement of Electrical Inspectorate/ EB authorities. Auxilliary contactor to be provided along with auto-manual switch where ever required.All MCCB Breakers both Incoming & Outgoing shall have LEDON / OFF / TRIPindications without fail. CTs shall be with dual ratioand cast resin type only. All doors to have double rubber gasket with shutter assembly & door seating frame.All AC feeders will have time delays of 0-60 Seconds. MCCBsof 250A Above willbemicroprocessor basedonly. Any panel if more than 1.5m width should be made in parts each part not exceeding 1.5m. The current density for Aluminum busbars shall be 0.8 only.All UPS outgoing panels shall haveneutral busbars double the size of phase. All MCCBs shall have plug setting from (40or50)-100%.All Lighting / RP and Lift panels shall have ELR for incomer of Prok. Dvs. Make only. All test certificates must be provided immediately after commissioning.SAFETY CERTIFICATE FOR THE PANELS SHALL BE PRODUCED FROM CEIG. All meters shall beDigitaltype only. FRLS PVC copper wires shall be used for control wiring 20 The MCCB should be current limiting type with trip time of less than 10 msec under short circuit conditions. The MCCB should be either 3 or 4 poles as specified in BOQ. MCCB shall comply with the requirements of the relevant standards IS13947 – Part 2/IEC 60947-2 and should have test certificates for Breaking capacities from independent test authorities CPRI / ERDA or any accredited international lab.Important Note : - Breaker discrimination study need to carried out & Breaker/Breaker frames need to be selected accordingly. Switch Board Designation :Main panelsupply, installation, Testing and Commissioning of Main Power Panel floor mounting type, dust and vermin proof by construction of 14 SG CRCA sheets with bolted construction, cable entry & exit provision for bottom/top, powder coated panel, surge arrester (1No) as per tender technical specification and the details mentioned below.METERS with RS 485.INCOMER:- 1 Nos – 315A TM 4P MCCB TPN 36 KA with FD KIT. 1 Set –315/5A CT CL 2, 15VA for metering with MFM Single Source, 1 Nos. –Digital type Ammeter (0-315A) with selector switch, 1 Nos. –Digital typeVoltmeter (0-500V) with selector switch, 1 Sets –LED type RYB indication lamp with control MCBs, 1 Sets –LED type ON/OFF indication lamp with control MCBs. OUTGOING:- 5 Nos - 63A TPN MCCB, 1 Nos - 40A TPN MCCB, 2 Nos-250A TPN MCB,Spare Refer SLDBUS BAR RATING:One set: 400A3phase + Neutral 35KA for 1 sec. AL. bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus. Voltage :415 V Construction :Single Front with Top Cable EntryDimension : To be assessed by ContractorLocation : Refer Electrical Equipment Layout. 21 The MCCB should be current limiting type with trip time of less than 10 msec under short circuit conditions. The MCCB should be either 3 or 4 poles as specified in BOQ. MCCB shall comply with the requirements of the relevant standards IS13947 – Part 2/IEC 60947-2 and should have test certificates for Breaking capacities from independent test authorities CPRI / ERDA or any accredited international lab.Important Note : - Breaker discrimination study need to carried out & Breaker/Breaker frames need to be selected accordingly. Switch Board Designation :CLEAN ROOM PANELsupply, installation, Testing and Commissioning of Clean Room Power Panel floor mounting type, dust and vermin proof by construction of 14 SG CRCA sheets with bolted construction, cable entry & exit provision for bottom/top, powder coated panel, surge arrester (1No) as per tender technical specification and the details mentioned below.METERS with RS 485.INCOMER:- 1 Nos – 250A TM 4P MCCB TPN 36 KA with FD KIT. 1 Set –250/5A CT CL 2, 15VA for metering with MFM Single Source, 1 Nos. –Digital type Ammeter (0-250A) with selector switch, 1 Nos. –Digital typeVoltmeter (0-500V) with selector switch, 1 Sets –LED type RYB indication lamp with control MCBs, 1 Sets –LED type ON/OFF indication lamp with control MCBs. OUTGOING:- 2 Nos - 125A TPN MCCB, 3 Nos-40A TPN MCCB, 3 Nos-25A TPN MCB,Spare Refer SLDBUS BAR RATING:One set: 250A3phase + Neutral 35KA for 1 sec. AL. bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus.Voltage :415 V Construction :Single Front with Top Cable Entry Dimension : To be assessed by ContractorLocation : Refer Electrical Equipment Layout 22 Servo Stablizer 80Kva 3PHASE STABILIZERSupply and Fixing Three phase full automatic compensation AC voltage servo stabilizer is 80kVA capacity, 3 phase 4-line with 175V-265V (phase voltage) / 304V-456V (line voltage) input voltage range, the default output is 3 phase 380V, other voltages are customizable. ±15% tolerance of input range for output voltage above 380V and ±20% of that below 380V. 23 Switch Board Designation : UPS OUTGOING PANELsupply, installation, Testing and Commissioning of Ground Floor Power Panel floor mounting type, dust and vermin proof by construction of 14 SG CRCA sheets with bolted construction, cable entry & exit provision for bottom/top, powder coated panel, surge arrester (1No) as per tender technical specification and the details mentioned below.METERS with RS 485. INCOMER:- 1 Nos – 125A TM TP+2N MCCB 25 KA. 1 Sets –LED type RYB indication lamp with control MCBs,1 Sets –LED type ON/OFF indication lamp with control MCBs.OUTGOING:- 6 Nos - 40A 10 kA TP+2N MCB, Spare Refer SLD BUS BAR RATING:One set: 125A3phase + Double Neutral 25KA for 1 sec. Cu. bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus. Voltage :415 VConstruction :Single Front with Top Cable EntryDimension : To be assessed by Contractor.Location : Refer Electrical Equipment Layout 24 DISTRIBUTION BOARDSLDB - 8 WAY (7 segment) MCB INCOMER DB: Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 8way MCB DB comprising of the following :INCOMER: 40A TPN MCB 10kA with all necessary connected accessories – 1No.32A DPMCB WITH 32A DPRCBO 30 mA – 3 Nos. as individual phase incomers OUTGOING:Each 32A DP RCBO outgoing consist of 8nos.610 A 10KASP MCB (C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate.With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be powder coated type fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc. 25 UPS - 12 WAY (7 segment) MCB INCOMER DB: Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 12way MCB DB comprising of the following :INCOMER: 40A 4P MCB 10kA with all necessary connected accessories – 1No.40A DPMCB WITH 40A DPRCBO 30 mA – 3 Nos. as individual phase incomers OUTGOING:Each 40A DP RCBO outgoing consist of 12nos.1620A 10KASP MCB (C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate.With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be powder coated type fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc. 26 LT CABLES & ENDTERMINATIONS For all items in the rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the sameSupply and Laying of following size PVC/XLPE (FR-LS) insulated outer sheathed (1100 V grade) copper/Aluminum armored & un armored conductor cable partly laid incable tray and partly laid in wall/ ceiling with suitable individual clamps at every 1 mtr interval . Cable tray will be measured and paid separately. Cable Tags to be provided at every 50mtr interval and at either side of the bends.Only for Lighting cables cable tie will be permitted other cables clamps to be provided.,4 Core 150 Sq.mm XLPE Aluminum armored Cable 27 4 Core 120 Sq.mm XLPE Aluminum armored Cable 28 4 Core 95 Sq.mm XLPE Aluminum armored Cable 29 4 Core 25 Sq.mm XLPE Aluminum armored Cable 30 4 Core 16 Sq.mm XLPE Aluminum armored Cable 31 4 Core 6 Sq.mm XLPE Copper armored Cable 32 4 Core 4 Sq.mm XLPE Copper armored Cable 33 3 Core 6 Sq.mm PVC Copper armored Cable 34 3 Core 2.5 Sq.mm PVC Copper Cable 35 3 Core 1.5 Sq.mm PVC Copper Cable 36 1 Core 25 Sq.mm PVC Copper armored Cable 37 1 Core 1.5 Sq.mm PVC Copper Cable 38 1 Core 2.5 Sq.mm PVC Copper Cable 39 LT CABLES & ENDTERMINATIONS For all items in the rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the sameSupply and Laying of following size PVC/XLPE (FR-LS) insulated outer sheathed (1100 V grade) copper/Aluminum armored & un armored conductor cable partly laid incable tray and partly laid in wall/ ceiling with suitable individual clamps at every 1 mtr interval . Cable tray will be measured and paid separately. Cable Tags to be provided at every 50mtr interval and at either side of the bends.Only for Lighting cables cable tie will be permitted other cables clamps to be provided., 4 Core 50 Sq.mm XLPE Aluminum armored Cable 40 4 Core 35 Sq.mm XLPE Aluminum armored Cable 41 Supply, Fixing of Termination kit(Glands & lugs) of the following size cables with suitable double compression glands with suitable crimping socket. The rate shall be inclusive of Gland Earthing Plate Prefabricated as per Gland Size with provision for connecting Cu.SWG and Cable Tags should be engraved type for all I/C,O.G& lighting Circuits consider Dowells / Comet (copper sockets for copper cables and Alu. Sockets for alum. Cable)4 Core 150 Sq.mm XLPE Aluminum armored Cable. 42 4 Core 120 Sq.mm XLPE Aluminum armored Cable 43 4 Core 95 Sq.mm XLPE Aluminum armored Cable 44 4 Core 25 Sq.mm XLPE Aluminum armored Cable 45 4 Core 16 Sq.mm XLPE Aluminum armored Cable 46 4 Core 6 Sq.mm XLPE Copper armored Cable 47 4 Core 4 Sq.mm XLPE Copper armored Cable 48 3 Core 6 Sq.mm PVC Copper armored Cable 49 1 Core 25 Sq.mm PVC Copper armored Cable 50 Supply, Fixing of Termination kit(Glands & lugs) of the following size cables with suitable double compression glands with suitable crimping socket. The rate shall be inclusive of Gland Earthing Plate Prefabricated as per Gland Size with provision for connecting Cu.SWG and Cable Tags should be engraved type for all I/C,O.G& lighting Circuits (copper sockets for copper cables and Alu. Sockets for alum. Cable) 4 Core 50 Sq.mm XLPE Aluminum armored Cable 51 4 Core 35 Sq.mm XLPE Aluminum armored Cable 52 WIRING - CIRCUIT CUM POINT WIRINGThe rates for all point wiring items shall also includesupplying and fixing of the Conduits,conduitspecials, bushes and other fittings,Approved GI saddles and grouting thesame for exposed conduit work,2 mm thick Outlet boxes and junction box,All fixing accessories such as clips, brass screws etc,Allwork & materials necessary for wiring a point circuit of anylengthfromtheFinal DistributionBoardto connectorviaswitch and shall include thecircuitwiring also except where identified. 53 Primary Light / Fan Point Wiring: Supply, wiring, connecting& commissioning of 3Runs1.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistrandedHR-FRLSH-LFcopper wires in 1.8mm thick MS conduits fixed on ceiling partly and1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition including supplying and fixing of modular 6A One way switch along with molded front plate in GI anodized manufacturers mounting box-Flat switches with indication fixed flush with the wall complete with all accessories including 3 plate ceiling rose.NOTE: Above false ceiling when it is open wiring it should be of MS conduit 54 Lighting Circuit Mains: Supply and laying of 3 Runs2.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistrandedHR-FRLSH-LFcopper wires in 1.8mm thick MS conduits fixed on ceiling partly and1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition., from LDB to Lighting Switch Boards and MCB to First Light Point. 55 SOCKETS Supply, Installation, testing and commissioning of 1nos 6/16AUniversal switched socket( UPS) and 1nos 16A switches and withmolded frontplate, GIanodized enclosure, and mounting box in the wall(concealed/open)andother associated accessories including chasing embeddingrough plastering as required as per the site conditions forpower points. 56 Supply & Laying of 2R 4 sq.mm and 1R 2.5 Sq.mm. PVC insulated FRLS multistranded cu wires 20mm dia 2 mm thick MS conduit with all accessories as reqd. (From DB to 6/16A Power Sockets / 20A Metal clad plug & sockets.). 57 Cat6 RJ45-RJ45 UTP Patch Cords, color matched, Yellow - Workstation end, 7 ft, Data-1 58 2-port Faceplate 59 4-pair, Cat6 UTP Cable, roll of 305m, LSZH 60 Cat6 24-port Unloaded Angled Jack Panel, 1U 61 Cat6 UTP Information Outlet for Jackpanel end 62 LIGHT FITTINGSSupply, Fixing, testing and commissioning of square type Recessed mounted LED luminaire 42 W (W)600x600 with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 63 EARTHING Supply, installing, testing and commissioning of maintenance free earth pipe of 3 mtr long T50 mm dia dual G.I pipe with flat buried in ground with back filling compound in an earth pit of 450 x 450 x 3000mm mixed with sand in alternate layers of 150mm each up to a height of 2550mm from bottom. The pipe shall have provision for connecting earth flats / wires. A masonry structure of wall thickness of not less than 230mm shall be constructed to a depth of 450mm and heavy duty SFRC cover shall be used to cover the pit. 64 Supply, Installation, testing and commissioning of earth plate of size 600 x 600 x 3mmcopper plate earth electrode at a depth 3000 mm in an earth pit of 450 x 450 x 350mm filled with salt and charcoal mixed with sand in alternate layers of 150mm each up to a height of 3000mm from bottom. Two copper flats of size 25 x 3 mm shall be braced to this copper plate throughout the overlapping length with the copper plate and brought to the surface of the earth pit. This plate shall have provision for connecting wires or flats as the case may be. A suitable size of 25/ 38mm dia GI pipe shall be provided up to bottom of the earth pit. This GI pipe shall have provision for watering through a funnel. A masonrystructure of wall thickness of not less than 230mm shall be constructed to a depth of 450mm and heavy duty SFRC cover shall be used to cover the pit. 65 Supply andlaying of following copper flats laid in open / buried underground / concealed manner withnecessary clamps, SMC insulators, screws, interlinks etc. for earthing . 50X10 mm GI . Flat for panel cable tray Body earthing 66 25X6mm GI . Flat for panel cable tray Body earthing 67 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required 68 8 SWG Cu. Wire for DBs earthing 69 25X6mm Cu Flat forearthing 70 SECTION-A : UPS / INVERTER SYSTEMSupply, installation, testing and commissioning of 3 kVA Inverter system with single phase input and single phase output with Battery stand complete all necessary accessories and tools as required as per site condition. Make : Schenider , Socomec 71 Supply, installation, testing and commissioning of 3x25KVAonline modular UPS System Three phase input & Three phase output, 50 Hz, 415 V complete. The UPS shall be microproccesor based online with IGBT based convertors (Rectifier & Inverter) and with automatic static by pass.The UPS system shall be provided with SMF batteries (including all the necessary accessories like racks/cabinets, interconnecting links/cables, battery circuit breaker etc.) with 20 minutes back up for each UPS, and communication interface. Quoted rates should be inclusive of Base Frame for the UPS with height of 300/450mm, Load testing (resistive load bank) for four hours/UPS with all necessary items. Supply, Installation testing and commissioning of 1No. of 3 Phase 75KVA UPS (0.99 IPF & <3% THDi) along with SNMP & Modbus card for the above said combination and all as per the enclosed SLD and specification mentioned above. (The rate shall also be inclusive of Remote display and alarm module for UPS failure notification with required cabling and accessories etc.)Supply, Installation testing and commissioning of batteries for 30 mins back up at 75KVAfull load including neceessary accessories like interconnecting cables between batteries ,interconnecting cables between battery bank and UPS and all as per technical specification. specification.Note : Vendor to submit Battery calculation sheet with battery catalogue. The rate shall inclusive of suitable battery circuit breaker with enclosure etc. Supply and installation of battery Rack for the above said batteries with all required accessories. (battery rack should be suitable to accommodate the batteries which is having 30minutes back up for 60KVA load) 72 Supply, Lifitng , Positioning , Installation, Testing and Commissioning Air cooled Inverter modular Chiller with Dual Circuit , EEV Precise Electronic Expansion valve, High efficiency PlateHeat Exchanger stainless steel plate, low water pressure drop, Smart control with touch screen for heating and cooling system, High Precision stepless energy modulation trane variable frequency unit, High efficiency fan design, Refrigerant R410A, Cooling capacity 130KW, Power input -38.1, Cooling 7DegreeC / 12 Degree C, COP(AHRI)- 3.41, IPLV-4.81, Compressor -2 Nos, Air flow- 23500x2 Nos, Water flow rate- 22.4 Cum/Hr consider Trane., Blue star, Samsung with necessary control panel isolator spring, complete all. 73 CHILLED WATER Primary PUMPS Supply and install of Design envelope close coupled vertical in-line pump in-built VFD with logic controller. Series Design Envelope Sensorless The pumps shall be radially split, single stage centrifugal type with Bronze fitted casing with equal size suction and discharge flanges and having separate tapped flush line and pressure gauge connections,dynamically balanced Bronze impeller, stainless steel shaft lower carbon throttle bushing, outside balanced type mechanical seal with carbon rotating face, Silicone carbide stationary seat Viton secondary seal.The pump motor shall be suitable for 415V+/- 10% Volts, 50 +/- 5% Hz, +/- 10% combined voltage and frequency variation, 3 phase AC power supply. The squirrel cage induction type, P base with TEFC enclosure ansd shall be connected the pump through a high tensile Aluminum slit type spacercoupling to permit servicing of the mechanical seal without disturbing pump, motor or electrical wiringconsiderKSB, Armstorng, Grundfos. Coupling shall be protected by a motor. Flow Rate GPM 100( 2 Working + 1 Standby ) of 32m head. 74 CHILLD WATER SYSTEM AHU Supply, Installation, Testing and Commissioning of vertical floor mounted double Skin AHUs Withmm Sand witched PUF Insulation,top discharge Fan with TEFCmotor, 12 row chilled water coil,pre filter section with filters of 90% efficiency down to 10 u,Limit Switch, Emergency Light, Guard for Inspection Door, Commissioning filters set, outlet damper, etc. of the following capacities with VFD starter panel complete all. including vibration pad etc.Extruded Aluminum Aero foil blade low leakage manual Fresh air damper. Flange type washable pre filter 10 micron EU4 Grade at Fresh air inlet. Pre Filter Section Flange type washable pre filter 10 micron EU4 Grade at Fresh air inlet. Cooling Coil Section8 Row Deep CHW Type coil (Cu Tube & Al fins). To achieve the 22 Degree If any changes coil row to be increased. SS 304 Insulated drain pan with Nitrile Rubber Insulation. BLOWER SECTION EC Fan top dischargeBLEED FILTER SECTION Flange type washable bleed filter 3 micron EU7 Grade at Bleed air outlet with Extruded Aluminum Aero foil blade low leakge manual bleed air damper.FINE FILTER SECTION . Flange Type washable Fine filter 3 micron EU7 Grade with frame. consider CVR Aircon, Air Prism tech, Thermoflex SUPPLY SECTION WITHExtruded Aluminum Aero foil manual volume control damper at supply & Return air outletDuct mounted heater .Magnehelic gauges for measuring differential pressure across AHU filters. Silicon tubes, necessary fixing accessories , screws etc. To avoid vibration on floor vibration isolation should be provided. classified area- 100000 class- 22 degree c , 50% RHAHU Capacity - 8000 cfm Fan static pressure in mm of wc-100Cooling capacity - 13.0 TR 75 Duct mounted heaters Supply, Installation, testing and commissioning of Duct mounted heaters with thyristor control. Cost shall be including of control panel with necessary temperature and RH sensor to control the heater complete all. Etc.-20 KW heaters( Can be spited as per required) for each units 76 AIR CURTAINSAir Curtains with wall mounted type, robust construction, powder coated finish, Aluminum impellers with low noise forward curved blades, adjustable louvers, vibration free operation, pre-lubricated both side sealed ball bearings for smooth running of Air curtain. The Air curtains are should be interlocked with door limit switch.Size: ( 2000Lx300Dx300H) 77 Size: ( 1000Lx300Dx300H ) 78 FRESH AIR UNITS Supply & Installation of Modular type Floor mounted Double skin FRESH AIR FILTER MODULES made of 25+/-2 puf (40±2 KG CFC FREE PUFFF) insulated panel with 0.63mm GI inner & 0.63mm pre coated GI outer skin. It comprising of filters section with flange type 20 micron filters down to 80% efficiency, consider Kruger ,Greenheck, Carryaire.KRUGER NICOTHRA, higher quality DIDW BLOWER with CG /Higher make non FLP IE-3 motor. Aluminum aero foil design volume control damper with operating knob handle.-5000 CFM. 79 VENTILATION AIR UNITSSupply & Installation of Modular type Floor Mounted Double skin ventilation AIR FAN MODULES made of 25+/-2 puf (40±2 KG CFC FREE PUFFF) insulated panels with 0.63mm GI inner & 0.63mm pre coated GI outer skin. KRUGER/NICOTHRA / Higher Quality MAKE DIDW BLOWER with CG /Higher Quality make non FLP IE-3 motor, consider Kruger ,Greenheck, Carryaire.Aluminum aero foil design volume control damper with operating knob handle.-4000 CFM. 80 AIR DISTRIBUTION SYSTEM Supply, installing, testing and commissioning of following items as specified and shown on the drawing for complete and satisfactory operation and control and to local authorities approval. Air distribution system consists of factory fabricated sheet metal rectangular ducting with reinforcement / stiffeners (manufactured through computer aided machine which has automatic provision for plasma cutting for the profiles and for auto folding) with TDF /TDC flanges, nuts and bolts, corners, clipsetc with suspenders with Gripple /Zip Clip cables, complete as per specification. consider Cosmic , Western air duct , Sreevinus The ducts shall be fabricated as per SMACNA standards. 18G thick GSS ducting– factory fabricated . 81 20G thick GSS ducting – factory fabricated 82 22G thick GSS ducting – factory fabricated 83 24G thick GSS ducting – factory fabricated 84 Supply, fabricating and erecting structure steel of make TATA/SAIL shall be confirm to IS:2062 along with test certificate as per specification including transporting, straightening, cleaning, fabricating and erecting various structures in position for ducting support, applying two coats of zinc chromate primer of ICI, Asain make or equivalent, with rubber gasket between support & duct as per specifications and drawings and as directed by the Engineer-in-Charge client /consultant. 85 Supply and erection of Nitrile rubber Insulation of Supply air duct with 19mm thick Armasound cross linked polyethylene foamed insulationwith aluminum foil thickness class-1, temperature range from -10ºC to +85ºC, Class 1 fire category and as per specification.- Return air duct 86 Supply and erection of Nitrile rubberInsulation of supply air duct with13mm thick, FM approved cross linked polyethylene foamed insulationwith aluminum foil thickness class-1, temperature range from -10ºC to +85ºC, Class 1 fire category and as per specification. 87 Supply and fixing of Spigot damper shall be installed from take off collar to diffuser plelum boxes(low leakage) consider Cosmic, Western air duct , Sreevinus,made out of 1.6mm galvanized sheet steel frame and blades of 1.0mm galvanized steel with suitable links. 250mm dia 88 100mm dia 89 Supply and installation of Flexible duct connections between main duct and diffuser plenums, Consider Cosmic , Western air duct , Sreevinus, shall be 25mm thick fiber glass pre-insulated, single ply / multiply Aluminum construction and with multiple layers of polyester film glass fiber covered with mechanical lock sheets/ Aluminum laminated jackets-Fire resistant complete with Pre-fabricated and powder coated Aluminum angle frame mounting brackets and supports.250mm dia. 90 Supply and installation of Powder coated extruded Aluminum linear grills for supply air grills Consider Cosmic , Western air duct , Sreevinus .The rate shall inclusive of Aluminum with collar damper, necessary fixing and supporting arrangement for the grilles. 91 Supply and installation of Powder coated extruded Aluminum linear grills for return air grills consider Cosmic , Western air duct , Sreevinus.The rate shall inclusive of Aluminum with out collar damper, necessary fixing and supporting arrangement for the grilles. 92 Supply and installation of GI volume controldamper, (low leakage) made out of 1.4mm thick galvanized sheet steel frame and opposed blades of 1.4mm galvanized steel with suitable links, handles, levers and quadrants for manual control of volume of air flow and for proper balancing of air distribution system consider Cosmic , Western air duct , Sreevinus. Rectangular type VCD -for future provision classified room damper to be provided. 93 Supply, installation of 4 way diffusers for Return air of neck size 550x550 94 SupplyFabrication , and erectionofDouble canvas connection made out of fire retardent canvas cloth with Zip required necessary fixing arrangements including nuts & bolts Etc 95 Terminal HEPA Filter Module (For ISO-7 & ISO-8 areas) Terminal HEPA filter module of GI powder coated sheet construction with volume control damper (shall be operated from the clean room), DOP test port, Mini-pleat HEPA filters with 99.97% efficiency, swirl type air diffusers at terminal level .HEPA Filter Size: 600 x 600mm / each up to 1000cfm 96 Supply and Fixing -UL 555 listed Moto raisedFire damper with 300mm sleeveDampers G.I.16G. The fire dampers of atleast 2 Hours fire rating with angle frame (on both sides of wall) and multi leaf dampers out of 18G with cross bush.The dampers to signal accidental closure through built in limit switch. Include for hard wiring between starter and Limit switch, including necessary Bolt, nuts & supports. 97 Supply, installation, testing and commissioning with belmo activator with necessary cables , control panel, to connect with AHU starter panel to control the fire mode. 98 Supply, laying & termination of 3C x 1.5Sq.mm power cabling between 230V single phase power socket to Actuator with necessary supports & clamps. 99 Supply & fixing of 16G M.S.Conduit for cable laid between actuator to AHU panel 100 MS PIPING Interconnecting MS with c class pipe work duly insulated with elastomeric nitrile rubber typetubular insulation as per specifications .All piping inside the room shall be properly supported with hanger.MS supports for piping & cables, using angles, channels, Tees, flats, etc should be considered as part of scope.All MS supports shall be given a coat of red-oxide primer and two coats of synthetic enamel paint of approved colour. 100 mm dia 101 80 mm dia 102 65 mm dia 103 Supply, installation of nitrile rubber insulation with Aluminum cladding of 26 Gauge complete all. 104 DUAL PLATE CHECK VALVES :( NRV )Supply, installation, testing & commissioning ofdual plate check valves, wafer type sleep-on construction.The valve bodyshall be cast iron as per IS 210 Gr. FG 220. The valve disk shall be aluminum - bronze plate, SS 316 inch pins & pins and springs rubber seal and should be rated for a pressure rating of ANSI 150and complete with with 30 mm thick PUFwithAluminum claddingthickness of 22G as per specification. 50 mm dia 105 Y-TYPE STRAINER :Supply, Installation, Testing and Commissioning ofY – Strainers CI fabricatedcomplete with SS - 304 perforated sheet basket having 3 mm perforated hole, PN-16 pressure rating body,Tabel-E flanged endsand duly insulated as per piping and specs.65 mm dia 106 BUTTERFLY VALVES : Supply, installation, testing & commissioning of Wafer type Butterfly valves with PN 16 pressure rating, Cast iron body , EPDM Seal, Stainless Steel 416 Shaft material, Nylon coated ductile iron lever lock handle and confirming to IS:13095, complete with companion slip on flanges as per BS10, nuts, bolts and gaskets as required.with 30 mm thick PUFwithAluminum claddingthickness of 22G.50mm Dia 107 65mm Dia 108 PRESSURE INDIPENDENT BALANCING AND CONTROL VALVE - PIBCV:Supply, Installation, Testing & CommissioningofPressure independent balancing cum flow control valve PN16, Cast Iron body with flanged end with modulating type electronic actuator, solid state temperature sensor and controller, power and control wiring, power supply unit etc. consider Donfos / Honeywell / Siemens.The valve actuator and sensor shall be IBMS compatible. with 30 mm thick PUFwithAluminum claddingthickness of 22G as per specification 80 mm dia . 109 PRESSURE GAUGES : Supply, Installation, Testing and Commissioning ofdial type pressure gauges made of Stainless steel with range selected so that normal operation is near to middle of the scale, consider Wari/ H guru.Syphons and cocks to be provided along with SS snubber. 110 DIAL TYPE THERMOMETERS : Supply, Installation, Testing and Commissioning ofdial type Dial type Thermometers of 100 mm dia shall be of mercury in steel type with range suitable for the temperature services.It should be installed in the thermowells as explained in the tender specifications.. 111 DRAIN VALVE :Supply, Installation, Testing and Commissioning of Ball Valve for drain with insulation. Nipple and dummy to be fixed after the gate valve of size 25 mm NB. 112 AUTO AIR VENT VALVES : Auto Air valves to beprovided at all high points in the piping system for venting. Valves shall be of the double float type with G.Mbody, vulcanite balls, rubber seating, etc. of 20 mm NB and shall be associated with an equal size gate valve with rising spindle. 113 Ball VALVES : G.Mbody, vulcanite balls, rubber seating, etc. offollowing size inmm NB and shall be associated50mm Dia. 114 25mm Dia 115 Leakage test for DuctingAll medium and high pressure ductwork at classified and unclassified area shall be seal class A and be leak tested as per IS-655.2006 leak test method Class-6 (rectangular duct) & soap solution.This has to be carried out through third party agency not the vendor. 116 Acceptance criteria for all classified area ducting (ISO-7): Rate of air leakage not to exceed 0.1% duct vol/min at 1000 Pa (4 in. w.g.) minimum test pressure. All instruments should be appropriately calibrated by an accredited laboratory. 117 Acceptance criteria for all classified area ducting (ISO-7): Rate of air leakage not to exceed 0.2% duct vol/min at 500 Pa (2 in. w.g.) minimum test pressure. All instruments should be appropriately calibrated by an accredited laboratory. 118 VALIDATION & DOCUMENTATION Validation including DQ, IQ, OQ & PQ protocols and certificates of all manufactured items, duct. Validation should include minimum following tests:- i) Air quantity, Air flow velocity and ACPH calculation ii) Pressure balancing iii) Filter leak test iv) Particle count test v) Recovery test vi) Air flow pattern vii) Temperature & RH monitoring for 3 days by data logger. Validation should be conduct for all three seasons (Three times / year) Immediately after commissioning, one validation after 6 months of system running and final validation at the end of guarantee period.Testing, adjusting, balancing, reporting and documentation of air distribution system carroed out through a third party commissioning agent. 119 Testing, adjusting, balancing, reporting and documentation of air distribution system carroed out through a third party commissioning agent. 120 FIRE EXITINGUISGHERS:- Portable ceiling mounted clean agent fire extinguishers manufactured as per IS with ISI marked suitable for wall mounting / floor mounting / trolley types with all accessories. -10kg with necessary ceiling mounted brackets up to the ceiling height maximum of 1200mm as per site condition, consider Safex, Ceasfire, Minimax. 121 4.5 kg. capacity carbon di-oxide fire extinguishers with wall mounting bracket 122 SITC OF SIGNAGE SYSTEM -FIRE EXIT - SINGLE SIDE 123 DIRECTIONAL EMERGENCY EXIT (AUTOGLOW SIGNAGE) - DOUBLE SIDE Make : Prolight 124 EXTINGUISHER Signages - Autoglow, with suspension chains (Autoglo signages, size 150 x 300) - double side 125 MCP Signages - Autoglow, with suspension chains (Autoglo signages, size 150 x 300 - double side 126 Fire Evacuation Route Map as per following specification Evacuation plan shall be glow in dark. A3 size with 5mm thick rear & 3mm thick front acrylic cover including wall mount supports. 127 ADDRESSABLE FIRE ALRM SYSTEM -Supply, Installation, testing & commissioning of 2 Loop Addressable Fire Alarm Control Panel - Total 640 Devices per loop 159 detectors/ 159 modular combination, consider Edwards Honeywell, Ravell 128 Supply, Installation, Testing and Commissioning ofAnalog Addressable Photo Electric Smoke Detector above with necessary base box complete all. 129 Supply, Installation, Testing and Commissioning ofAnalog Addressable Photo Electric Smoke Detector below with necessary complete all. 130 Supply, Installation, Testing and Commissioning ofResponse Indicators. 131 Supply, Installation, Testing and Commissioning of Addressable Manual Pull Station . 132 Supply, Installation, Testing and Commissioning ofSounder Cum Strobe . 133 Supply, Installation, Testing and Commissioning ofAddressable Short Circuit Isolator Module 134 Supply, Installation, Testing and Commissioning ofAddressable Control Module. 135 Supply, Installation, Testing and Commissioning ofAddressable Monitor Module . 136 Supply, Installation, Testing and Commissioning ofJunction Box. 137 Supply & Laying of 2C X 1.5 Sq.mm Shielded Copper armored Cable, including clamps, fixing accessories complete all. 138 Supply & Laying of 4C X 1.5 Sq.mm Shielded Copper armored Cable,including clamps, fixing accessories complete all. 139 Supply, Installation, Testing and Commissioning of power supply unit 140 4 reader controller with cabinet and power supply backup. as per specification. 141 Multitech T15 reader 142 Supply, Installation, Testing and Commissioning of surface / flush mounted (as required at site) Magnetic Contact (Door position sensor)for access controlled doors as per the tender specification. 143 Supply, Installation, Testing and Commissioning of exit switch & accessories with 2.5mm thick SS front plateas per specification suitable for mounting on metal surface/metal frames or wooden frames wall or as required based on site conditions including all accessories. 144 Supply, Installation, Testing and Commissioning of Buzzerfor access controlleddoors as specified inthe Tender Specifications 145 Supply installation, testing, commissioning of EDR (EMERGENCY BREAK GLASS) 146 Supply andlaying of 4 core 1.0 Sq mm Un armored Shielded FRLS, Multistranded Copper Conductor, PVC sheathed Cable for connecting controller to Lock & door position sensors, Buzzer,BGU,Pushbutton as per the tender specificationsRate shall inclusive of 2mm thick suitable dia FRLS PVC conduits with ,JBs in wall, columns, ceiling etc., including associated civil works. 147 Supply andlaying of 8 corex 1 Sq mm Un armored Shielded FRLS, Multistranded Copper Conductor, PVC sheathed Cable for connecting controller toreaders as per the tender specificationsRate shall inclusive of 2mm thick suitable dia FRLS PVC conduits with ,JBs in wall, columns, ceiling etc., including associated civil works. 148 Supply andlaying of 2 corex 1 Sq mm Un armored Shielded FRLS, Multistanded Copper Conductor, PVC sheathed Cable Rate shall inclusive of 2mm thick suitable dia FRLS PVC conduits with ,JBs in wall, columns, ceiling etc., including associated civil works. (conduits & cables - blue color) 149 Supply andlaying of MS Powder coated Trunking 150 x 50 mm x 2mm with cover &fixing suppports etc as required 150 Supply andlaying ofCAT6 cable in PVC FRLS Conduits (this item inclusive of necessary patch cords,I/Os& terminations ) - for connecting Controller/Reader with IP switch 151 Supply, Installation, Testing and Commissioning ofLocal scare alarm with required wiring between LCA & door contacts (For fire exit doors). 152 VIDEO SERVILANCE SYSTEM - Supply, installation, testing and commissinoning of, 5 Megapixel low light power over -coax(PoC),Dome type HD Output, up to 720 P resolution, Low illumination, 3.6mm lenss, tru day / Night , OSD menu,Smart IR, Up to 40 m IR Distance, necessary suports, complete all.consider Hivision, Dohua, Honeywell. 153 Supply & Installation of Network Video Recorder with 8 HDDs Storage Capacity, 32-Channel Video, Client Licenses, & supports H.264 Compression, Real time Surveillance, The data should be stored 90 days (Hard disk to calculation report to be submitted). -8 TBHard disk which ever is to be check 154 Supply, installation, testing and commissioning of 42 Inches HD LED Television (TV)/Moniterwith Resolution: 1366 x 768 Pixels and 2 HDMI out put. With necessary power cable complete all. 155 Supply, installation , testing and commissioning of PYE swith ( Power on Ethernet) with necessary arrangement complete all. 156 Supply, installation of Cat 6 cable with 25 mm PVC conduit with necessary L, bend, flexible conduit , clamps complete all. 157 Supply and laying of 2Cx 1.0 Sq.mm FRLS cable with suitable accessories etc. 158 Supply and fixing of power supply unit complete all. 159 PLUMBING & SANITARY WORKS: Supply, fixing of 15mm dia Sensor Pillar cock with necessary flanges suitable for under counter wash Basin . Jaquar Make - SNR- CHR 51011 160 INTERNAL WATER SUPPLY -Supply and installation testing and commissioning ofpipe CPCV SDR-11 as per IS 15778including fittings, supports, clamping ,flow indication colour band ,pipe name marking etc complete in all respects. Including wall chasing and finishing the wall in good condition as per original complete all. -20 NB 161 Supply, erection, testing and commissioning of CPVC valve of the following sizes including nipple etc complete in all respects of following sizes. -20 NB 162 Supply, installation of digital type water meter with necessary fixingaccessories complete all. -32 mm dia 163 INTERNAL DRAINAGE SOIL AND WASTE PIPES , INTERNAL- Supplying and laying P.V.C Pipes of 6kg class ofIS:4985 - 2000and P.V.C.Pipe specials of cutting to required length, Erectionpipe specials along with P.V.C.Pipe, Making ring seal couplers to join the pipe and pipe specials. 110mm dia, using internal and external including excavation and complete all. with necessary wall clamps.Internal & External - 110 mm dia pipe -6 kg/cm2 164 75 mm dia pipe - 6 Kg /Cm2 165 50mm dia pipe- 6kg/cm2 166 supply installation of floor drain fabricated as per site condition 167 LIGHT FITTINGSSupply, Fixing, testing and commissioning of LED luminaire 28 W Linear Suspended light fitting with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 168 LIGHT FITTINGSSupply, Fixing, testing and commissioning of LED luminaire 20 W Linear Suspended light fitting with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 169 LIGHT FITTINGSSupply, Fixing, testing and commissioning of surface mounted type LED luminaire 15 Wlight fitting with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 170 Supply, Installation testing and commissioning of 1No. of 3 Phase 10 KVA UPS (0.99 IPF & <3% THDi) along with SNMP & Modbus card for the above said combination and all as per the enclosed SLD and specification mentioned above. (The rate shall also be inclusive of Remote display and alarm module for UPS failure notification with required cabling and accessories etc.)Note : Vendor to submit filled compliance for both specification sheet & Data sheet . Supply, Installation testing and commissioning of batterries for 15 mins back up at 10 KVAfull load including neceessary accessories like interconnecting cables between batteries ,interconnecting cables between batterry bank and UPS and all as per technical specification. specification.Note : Vendor to submit Battery calculation sheet with battery catalogue. The rate shall inclusive of suitable battery circuit breaker with enclosure etc. Supply and installation of battery& Rack for the above said batteries with all required accessories. (Each set of battery rack should be suitable to accommodate the batteries which is having 30minutes back up for 10 KVA load). 171 Supply, installation, testing and commissioning of BACNet compatible Ultrasonic BTU meter as per the system requirements for tenant billing. 100 mm dai 172 80 mm dia 173 65 mm dia 174 Supply, Installation, testing and commissioning of Control panel for above BTU meters to control the PIBCV with necessary wiring complete all. 175 Supply, instalaltion of Thermowell of ss as per requirement with insert type temperature sensor complete all. 176 Supply and installation of Flexible duct connections between main duct and diffuser plenums shall be 25mm thick fiber glass pre-insulated, single ply / multiply Aluminum construction and with multiple layers of polyester film glass fiber covered with mechanical lock sheets/ Aluminum laminated jackets-Fire resistant complete with Pre-fabricated and powder coated Aluminum angle frame mounting brackets and supports. 100mm dia 177 Air terminals : Supply & installation of Terminal module of 16/18 G GI powder coated material, leak proof construction with grill fixing provision, duct connection provision, fixing hold fastener, and . Gear Type Damper operating knob provision should be bottom. Module size: 680 x 680mm or MFD Std. but Suitable for 610 x 610 x 300 / 150 deep 178 Module size: 540 x 540mm or MFD Std. but Suitable for 450 x 450 x 300 / 150 deep 179 SIZE :450 x 450 x 300 / 150 deep 180 SUPPLY AIR GRILLS : Grill size: 745 x 745 mm or MFD Std. 181 Grill size: 600 x 600 mm or MFD Std. 182 Supply grill for IOT Control air vent system for the cleanroom to monitor and control temperature and RH, via mobile or desktop application, damper with neceeary activator, control cabling, as per client requirement. Including conduit clamps complete all. 183 Supply, installation, testing and commissioning of control panel for the above with necessary controller for automatic and manual both options complete all. 184 RETURN AIR MODULES : Supply & installation of Raiser module of 16/18 G GI powder coatedmaterial, leak proof construction with grill fixing provision, duct connection provision, fixing hold fastener, and . Gear Type Damper operating knob to Control The Air -Grill Module Size : 540 x 540 x150 mm 185 RETURN AIR RISER GRILLS : RETURN/EXHAUST Air RISER mounted module grills made of SS-304 Mirror polished in front (180 grit) in 16 G Perforatedgrills fixing to the Terminal module ( Grills fixing blind bush suitable to M-6, SS-304 doom bolts). SS 304 grill For Raisers (as per drawing) 186 SS 304grill For Grill Modules 187 RETURN AIR RISER FILTERS: Return/ExhaustAir False ceiling mounted Terminal filters made of 16G GI Powder coated filter Box with flange type casing and 10micron down to 90% efficiency. Filter media shall be SNPF [WASHABLE] -700 x 450 x 20 MM 10 Micron filters and control damper (as per dwg) 188 Supply, Installation, Testing & Commissioning of Piping system with SS 316L confirming to ASTM A 269, Internally electropolished to 10 Ra micro-inch surface finish and ends capped, orbitally robotic welded along the circumferance, properly colour coded as per IS standard with following diameterand wall thickness as noted below with flow arrow, service metal band and colour stickers as per IS standards. Approved make: Sandvik/Sumitomo. 8.0 MM for compressed air as per client requirement and layout. 189 Supply, installation, testing and comissioning ofBall Valvewith Ferrule tube fittingsEnd connection-Swage lock Class- 150#Ball construction- Single Piece, Body- SS316LBall - SS 316LApproved Make: Swagelok -8 mm 190 Supply, installation, Calibrated, and commissioning of SS Buordon type pressure gauge with100 mm dial dia, syphone tube, needle valve and the scale range 0-20 bar. 191 Supply, Installation of 40 NB Digital vertex type flow and consumption meter for Compressed air application. Max flow 124 CFM at 8.5 bar. 192 Supply, Installation of following size of GIrubber line Split clamp. - 8.0 MM 193 Supply, Installation ofGI slotted C - Channel 40 x50x40 2mm thick for compressed Air pipe support. 194 Warranty for all the above items.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
21.
Health and Family Welfare #10220033 Price Bid
Supply Installation Of Machinery/ Equipment, Medical Gad Pipeline Work And Other Essential Items. , List Of Machine And Equipment , Vertical Blinds Providing And Fixing White, Semi-Transparent, Roller Blinds/ Vertical Blind 100 Mm, All Complete, With All Fixing Mechanisms, In Specified Color/Texture/Screen, As Per Attached List, All Complete With Installation& Testing , Dirty Linen Trolley • Heavy Steel Frame Mounted On Four 100 Mm Heavy • Duty Pu Swivel Castors; Two With Brakes. • Two Multipurpose Shelves With One Top Tray With Three Sides Safety Rails. • Provided With One Canvas Bag. • Size: 18 L X 18 W (Shelves) X 35 H + 18 L X 18 W (Canvas Bag). • Finish: Pre-Treated & Epoxy Powder Coated. • Certification- Iso 13485:2016, Iso 14001:2015, Gmp, Iso 50001, Iso 45001 , Floor Cleaning Trolley • Trolley Having 3 Bin • Capacity Of Each Bucket 25 Liter • Long Handle For Easy Handling. • With A Utility Bin And Mop Holder. • The Frame Of The Trolley Must Be Of Stainless Steel , Waste Bucket-Ss Small For Each Bed • Perforated Dustbin Without Lid • Material: Ss • Capacity :6 Liter • Size: 7 Inch X 10 Inch • Certification- Iso 13485:2016, Iso 14001 , Mayo Trolley • Specially Designed Instrument Trolley For Cross Over The Table. • Height Adjustable Manually Through Knob. • Complete Stainless-Steel Structure With Fixed Stainless • Steel Instrument Tray With Three Sides Safety Rails. • Mounted On Four 100 Mm Heavy Duty Moulded Pu Castors; Two With Brakes. • Size: 36 L X 24 W X 32-48 Height Adjustable. • Finish: Well-Polished Stainless Steel. • Certification- Iso 13485:2016, Iso 14001:2015, Gmp, Iso 50001, Iso 45001 , Refrigirator • Direct-Cool Refrigerator; 235Litres • Energy Rating: 5 Star • Warranty: 1 Year On Product, 10 Years On Compressor • Smart Inverter Compressor • The Revolutionary Smart Connect Technology In Lg Direct Cool Refrigerator Helps You Connect Your Refrigerator To Home Inverter In Case Of Power Cuts • Moist ‘N’ Fresh Is An Innovative Lattice-Patterned Box Cover Which Maintains The Moisture At The Optimal Level • Spill Proof Toughened Glass Shelves • Stabilizer Free 90V To 310V , Water Cooler Providing And Fixing 150 Litre/ Hr. Cooling And Storage Capacity, Fully Stainless Steel Electric Storage Type Water Cooler ( Blue Star Model No. Sdlx 15150 Or Equivalent) With Inlet Hose Connection Inbuilt Float Valve. 2 Nos. Outlet Faucet, Drain Tray With Waste And Pipe Up To Floor Trap Heavy Compressor And Wire Up To Socket, 3 Pin Plug Etc Complete In All Respect. , Track System • Strong Aluminum Track With Whit Powder Coated Finish • Curtain Of Polyster Fabrics Water Repellent And Stain Retardent • Curtain Size : 4 X 7 Feet • With All Other Accessories To Cover Each Bed , Iv Tree System • Heavy Duty 5 Bag Holder • Heavy Duty Self Locking Wheeled Trolleys • Five Point Telescopic Carrier Tree • Made Of Stainless Steel Ss304 And Aluminium With White Powder Coatint On It & Hook Are Of Ss304 • Strong Aluminum Track With Whit Powder Coated Finish • Track Suspended At Cubicle Track Height. • With All Other Accessories For Each Bed , Medical Gas Pipeline System Certification-Iso 9170-1:2008, Iso 10524-1:2006, Iso 7396-1:2016, Iso 5359:2014, Iec 60601-1-8:2006, Ce, Iso 80601-2-13:2022, Iso 15002:2008, Iso 21969:2009. , Fully Oxygen Mainfold (Without Cylinders) • Supply, Installation, Testing And Commissioning Of Fully Oxygen Manifold 8+8 , Fully Automatic Oxygen Control Panel For Main Fold • Supply, Installation Testing And Commissioning Of Fully Automatic Oxygen Control System, As Per Htm/ Iso7396/ Nfpa-99 Standard And Ce Certified Under Class Ii Medical Directive 93/42/Eec From Notified Body Or Ul/Atl Listed , Oxygen Emergency Mainfold System (Without Cylinders) • Supply, Installation, Testing And Commissioning Of Emergency Oxygen Supply System 2+2 , Oxygen Flow Meter With Humidifier Bottle • Supply Installation, Testing And Commissioning Of Oxygen Flow Meter With Humidifier Bottle 0-15Litres, And Cemarked Under Medical Directive 93/42/Eec , Gas Outlet For Oxygen • Supply, Installation, Testing And Commissioning Of Gas Outlet Points With Probe For Oxygen, Nitrous Oxide, Air, & Vacuum As Per Technical Specification As Per Htm/ Iso 7396 Standard And Ce Certified Under Class Ii , High Pressure Tubes Color Coded • Supply Installation Testing And Commissioning Of High Pressure Tubes Duly Colour Coded For Oxygen , Nitrous Oxide Compressed Air And Vacuum As Per Technical Specification And As Per Htm/ Iso 7396/ Nfpa-99 Standardand Ce Marked. , Medical Grade Copper Pipe Line • Supply,Installation Testing Commissioning Of Medical Gradecopper Piping Bsen : 13348 Lloyds Certified , 42Mm Odx1.2Mm Thick , 28Mmodx 0.9Mm Thick , 22Mmodx 0.9Mm Thick , 15Mm Odx0.9Mm Thick , 12Mm Odx0.7Mm Thick , Zonal Valve Box • Supply, Installation, Testing And Commissioning Of Zonevalves Boxesas Per Technical Specification. The Isolation Valves Used For The Shall Be Degreased For Oxygen Use 1 Gas Services , Medical Gas Alarm Panel • Supply, Installation, Testing And Commissioning Of Medical Gas Alarm Panel As Per Tender Specificationsas Per Htm/ Iso 7396/ Nfpa-99 Standard And Ce Certified Under Class Iimedical Directive 93/42/Eec From Notified Body Or Ul/ Atl Listed. , Master Alarm Panel , Area Alarm Panel , Line Isolation Valves • Isolation Valve , Degreased For Oxygen Use As Per Htm/ Iso 7396/Nfpa-99 Standardand Ce Certified Under Class Ii Medical Directive 93/42/Eec From Notified Body Or Ul/Atl Listed , 42Mm , 28Mm , 22Mm , 15Mm , 12Mm , Bio Medical Waste Trolley • Three Compartment Waste Segregation System. • Stainless Steel Trolley On Castors. •Foot Operating System For Opening Of Lid. •Bins Can Be Interchanged As And When Required. • For Bin Sizes 30 Ltrs , Bio Medical Colored Bin • Washable / Autoclavable • Lateral And Central Handles Tested For Twice The Max Weight. • Solidity & Resistance Against Shock At Both Low And High Temp. • High Penetration Resistance. • The Bins Comply Un And Nfx Standards Of Safety. • Bin Size 30 Ltrs , Bio Medical Colored Bags • Biodegreadable •Environment Friendly •Chlorine Free •Meets All Bmw Disposal Norms • Size As For 30 Ltrs Bin , Oxygen Concentrators • Flow Rate: 0-5/Min/0-10L/Min • Purity: 93+3% • Outlet Pressure: 0.04-0.07 • Sound Level: <- 50Db • Power:Ac230v, 50Hz (Ac220v/110+-10%, 50/60+-1Hz Are Available) • Power Consumption: <-480W • Lcd Display : Switch Times, Operating Pressure, Present Working Time, Accumulating Time, Presenting Time From 10Mins To 40 Hours • Alarm : Power Failure Alarm, High & Low Pressure Alarm • Net Weight : 25Kgs • Size (Mm):365X375x600 • Certification- Iso 13485, Ce , Fingure Tip Pulse Oximeter • Display Type : Led Display • Spo2 Measurement Range: 35-99% • Pulse Rate Measurement Range: 30-240 Bpm • Accuracy : +-1 Bpm • Operating Temperature : 0 Deg C – 40 Deg C • Product Dimension: 30X65x40mm • Certification- Ce, Iso13485 , Defibrillator D-Fab • Display: 7” Colour Tft • Display Area: 150Mmx 90Mm • Dimension: 14280 X W 330 Xd220mm (Max) Without Paddle • Alarm : 24 Hrs Graphical And Tabular Trend Of Ecg, Spo2, Nibp Esco2 Defib (External Paddles) • Operating Mode : Manual • Waveform: Biphasic Truncated Exponential • Energy : 2 To 200 Joules In 12 Steps Selection Heart Rate • Range: 10-250 Bpm • Accuracy : +- 2 Bpm • Resolution:1 Bpm • Alarm Limit Setting: 10-250 (Step Of 1) Ecg • Frequency Response : 0.5 Hz To 35 Hz • Lead Selection :Lead I,Ii And Iii • Gain Setting:0.5 1.0 And 2.0 • Cmrr :> 90 Db • Sweep Speed:12.5, 25.0, 50.0 Mm Sec Power Supply • Input:150-276 Vac, 50 Hz, I O • Battery :12V 4.5Ah, Rechargeable, (Sealed Lead Acid) • Back-Up Time: 3 Hours Min, On Full Charge In Ecg Mode 70-100 Shoeof 150 Joules Delive(Full Charge) • Power Consumption : 30 Watts (Max.) In Ecg Mode Aed Mode • Wave Form : Biphasic Truncated Exponential • Aed Shock Series:Energy Level 200J Environmental • Operating Temp : -5 Degree Celsius To +50 Degree Celsius • Humidity: Up To 95 % Non-Condensing • Certification- Iso 13485, Ce , Suction Apparatus – Foot • Portable And Lightweight Design For Easy Transport & Use In Various Settings. • Operates Using A Foot Pedal Instead Of Electricity, Making It Suitable For Use In Locations Without Access To Power Sources. • Can Generate Sufficient Suction Pressure For Medical Procedures Such As Wound Care, Tracheostomy Care & Airway Clearance. • Easy To Clean & Maintain, With Minimal Parts & Components That Require Servicing. • Durable Construction To Withstand Repeated Use In Clinical Environments. • Adjustable Suction Levels To Accommodate Different Patient Needs & Procedures. • Compatible With A Variety Of Suction Canisters And Tubing For Versatility In Use. • Cost-Effective Alternative To Electric Suction Machines, Particularly In Resource-Limited Settings. • Certification- Iso 13485:2016, Iso 14001:2015, Gmp, Iso 50001, Iso 45001 , Ecg Machine Features • 7 Inch Tft, Touch Screen, Led Back Light • Digital Information Technology And Signal Processing Solution, Digital Filter •Patient Management, Name Age And Id. Detail Analysis Report. •Built In Lithium Rechargeable Battery, Wide Thermal Printing System. • Usb And Lan Socket. • Memory: Built-In Memory Or Mini Sd Memory Card. Stores More Than 1000 Pieces Of Archive • Auto-Measurement, Auto-Analysis, And Auto-Interpretation. Technical Parameters • Lead: Standard 12 Leads • Patient Leak Current : < 10Ua • Input Impedance: >= 50M • Frequency Response: 0.05- 150 Hz(-3Db) • Time Constant : >3.28 • Cmrr: > 100Db • Dimension Of Recording Paper: 110Mmx20mtr • Paper Speed: 25Mm/S, 50Mm/S • Sensitivity Choice: 5, 10.20Mm/Mv • Measurement Parameters : Hr, P-R Interval, P-Qrs Duration, Q-T Duration Interval, Q-Tc, P Axis, Qrs Axis, R(V5), S(V1), R(V5)+S(V1) • Product Safety Type: Class I, Cf, Defibrillation, Pacing Protection. • Enduring Polarization Voltage: +/-300,Mv • Nosie Level: < 15Uvp-P • Dimension: 130Mm(L)+74Mm(W)+25Mm(H) • Net Weight : 2.3Kg • Certification- Iso 13485, Ce , Gulucometer • Assay Method- Electrochemistry. • Coding- Auto Coding. No Coding For Easy To Use. • Enzyme Compatibility - Gdh-Fad. • Test Time- 5 Seconds. • Sample Volume- 0.5 Ml. • Sample Type- Whole-Blood, Capillary, Venous, Neonatal. • Reference Type- Plasma Reference. • Memory- 500 Test With Date & Time. • Test Range- 10 To 600Mg/Dl. • Power- 3V Battery Cr 2032. • Universal Check Strips- Should Be Available With Every Meter. • Certification- Ec, Gmp, Iso 9001 (Nabcb) • Customer Care And Service Engineer Availability Is Mandatory. , Gluco Strip • Enzyme- Gdh-Fad. • Manual Coding Requirement- No. • Number Of Strips Packed In Each Container- 50*2 • Certification- Usfda, Iso15197:2015,Eu- Ce, Iso 13485:2016 • Electrode- Gold Layer. • Hct Range- 0 To 70%. • Strips Self Life Months – 24. After Opening Till Expiry Date (Print On Container). • Availability Of Test Report From Central Gov/Nabh/Ilac Accredited Lab. • Control Solution Should Be Available For Sample Testing, Service If Required. • Certification- Ec, Gmp, Iso 9001 (Nabcb) , Lancet • .Fine 30Gauge, Tri-Bevel Tip For Virtually Painless Sampling. • . Consistent Depth Penetration. • .Universal Design Should Be Fit For Most Lancing Device. • . Length - 1.2Mm Width -0.32Mm • .Gamma Radiation Sterilized For Hygiene. • Certification- Ce , Iso13485 , Ambu Bag Adult • Silicon Adult Resuscition Set With Ballow Capacity 1000Ml • Oxygen Reservoir Bag 2600Ml • Disposable O2 Tubing 2 Mtr • Silicon Mask – 2 Nos • In Zip Pouch • Certification- Ce, Iso13485 , Oxygen Cylinder (D Type) With Trolley • Cylinder Water Capacity : 46.7 Liter • Cylinder Oxygen Capacity : 7000 Liter • Weight Of Cylinder: 51 Kg (Approx) • Height Of Cylinder With Valve: 1445 Mm (Approx) • Certification- Iso 13485:2016, Iso 14001:2015, Gmp, Iso 50001, Iso 45001 , Wheel Chair • Folding Wheel Chair With Fixed Arm And Foldable Footrest • Chrome Plated Ms Frame. • Superior Quality Wheels • Certification- Iso 13485:2016, Iso 14001:2015, Gmp, Iso 50001, Iso 45001 , Weighing Scale Digital • Unit : Kg/Lb • Screen: 74X2.9Cm • Material : Tempered Glass + Abs Plastic • Battery:2Xaaa Batteries • Color :Customized Color • Pattern Type :Silk Print • Thickness Glass:6Mm • Glass Angle :Right Angle • Certification- Ce, Iso13485 , Clinical Thermometers (Digital) • Takes 60 Seconds To Measure Body Temperature. • Can Be Used In Oral Cavity, Rectal, Under The Armpit. • Easy To Read Lcd Display - Toggle To F And C • Beep Sound - Accuracy +- 2 Degree F • Range Of Measurement-89.6 Deg F To 109.2 Deg F • Certification- Ce, Iso13485 , Bp Appapratus (Digital) • Applicable Arm Circumference: 32Cm – 36Cm • Measurement Method : Oscillometric Method • Display Method : Lcd Digital Display • Measurement Range:Pressure 0 Mmhg – 280 Mmhg (0 Kpa -37.3 Kpa) Pulse : 40 Beats/Min -195 Beats/Min) • Accuracy : Pressure : +- 3Mmhg (+-0.4 Kpa) Pulse: Allowable Error +-5% • Power Supply : 4 Aaa Batteries (Dc 6V) • Storage & Transport Environment:Temperature -20 Deg C-55 Deg C • Normal Working Environment:Temperature -5 Deg C -40 Degc • Dimension (Approx.): 120Mm X 110Mm X65mm (L*W*H) • Components Included:Monitor, Arm Cuff, Storage Bag, User • Manual (Warranty Page) • Inflation/Deflation : Automatic • Screen Size/Type: 7.5Cm, 3 Colour Backlit & Pvc Pane • Certification- Ce, Iso13485 , Stethoscope • High Automatic Sensitivity • Soft Sealing Ear Knobs • Two Side Chest Piece • Quality Tubing • Imported Diaphragm • Certification- Ce, Iso13485 , Nebulizer • Power:230V Ac,50 Hz • Maximum Power :75W • Medication Capacity : 5Ml • Particle Size:0.4 To 8 Um • Mmad :4Um • On Time:30 Minutes • Sound Level:70 Dba (1 Meter) • Nebulization Rate:0.2 Ml/Min Or Above • Compressor Pressure Range:28 Psi • Operating Pressure Range:8 To 16 Psi • Compressor Air Output :10Lpm • Operating Temperature Range: 0 To 40 Deg C • Operating Humidity Range: 10 To 75 % Rh • Storage Humidity Range :90 % Rh (Max) • Certification- Ce, Iso13485 , Syringe Destroyer With Needle Cutter • High Temperature Incarnation Of Used Needles To Ensure Proper Disposal And Prevent Needle Reuse. • Easy To Use & Operate With Simple On/Off Switch. • Compact And Portable Design For Convenient Use In Medical Settings. • Built-In Safety Features To Prevent Accidental Burns Or Injuries. • Energy Efficient Operation For Cost Savings And Environmental Sustainability. • Durable Metal Body Construction For Long Lasting Use And Stability. • Sharp Cutting Blade For Precise And Efficient Syringe Cutting. • Compact And Lightweight Design For Easy Handling And Storage. • Easy To Assemble And Disassemble For Cleaning And Maintenance. • Cost Effective Solution For Safe Disposal Of Used Syringes In Healthcare Facilities. • Certification- Iso 13485:2016, Iso 14001:2015, Gmp, Iso 50001, Iso 45001 , Patient Trolley – Ms • Overall Size : 210L X 56W X 81H Cms • Frame Work Of Mild Steel, • Adjustable Back Rest. • Collapsible Safety Side Railings. • Cylinder Cage. • Removable Stretcher Top. • Pre Treated And Epoxy Powder Coated Finish • Wire Mesh Stretcher Platform. • Certification- Iso 13485:2016, Iso 14001:2015, Gmp, Iso 50001, Iso 45001 , Equipment Trolley • Strong And Precise Stainless-Steel Frame Made Of Rectangular S.S. Pipes Fixed With Six S.S. Shelves Fitted With S.S. Side Safety Rails On Three Sides Of Each Shelf. • Space Between Five Shelves Can Be Adjustable By One Inch Or Two Inches Or Shelves Can Be Detached As Per Space Required For Different Makes Of Laparoscopy/Endoscopy Equipments. • One Drawer Provided Under The Base Made Of Both Side Laminated Wooden Board With Large Stainless-Steel Handle. • Fitted With Electric Socket Strip Of Eleven Modular Sockets On The Rear Side Of Trolley. • Provided With Detachable S.S. Cylinder Cage At The Rear Side Of Trolley. • Trolley Moveable On Four 125 Mm Heavy Duty Moulded Pu Swivel Castors; Two With Brakes. • Finish: Well-Polished Stainless Steel. • Certification- Iso 13485:2016, Iso 14001:2015, Gmp, Iso 50001, Iso 45001 , Crash Cart • Crash Cart For Hospital Made With Stainless Steel, Completely Rust-Free Design. •6 Polystyrene Lockable Storage Drawers With Multi Colour Bins. •Available With Castors (Two Casters With Break) •Dimensions – 960Mm(L)X450mm(W)X1580mm(H) •The Inbuilt Oxygen Cylinder Holder And Inbuilt I.V Stand. • Certification- Iso 13485:2016, Iso 14001:2015, Gmp, Iso 50001, Iso 45001 , Patient Monitor • 12.1 Inch High Resolution Color Tft Lcd Screen. • Thinner And Lighter Design, Convenient And Portable For User, Pace-Maker Detection. • Freeze Instant Waveform For Real Time S-T Segment Analysis. • Real Time S-T Segment Analysis, Pace-Maker Detection. • 3-Level Audio Visual Alarming. • Efficient Resistance To Interference Of Defibrillator And Hf Knife. • Lasting Working Capacity With Built-In Rechargeable Lithium Battery. • 400 Groups Of Nibp List, 6000 Seconds Ecg Waveform Recall, 60 Alarm Events Recall, 7-Day Trend Chart In Storage. • Wire/Wireless Central Monitoring System Applicable To Icu/Ccu/Or. Standard Configuration: • Spo2, Pr/Hr, Nibp, Ecg, Resp, 2-Temp. • Certification- Iso 13485, Ce , Over Bed Table With Adjustable Mechanism • Abs Moulded Top Fitted On Heavy Steel Frame With Heavy Base Made Of • Crca Pipe Frame Mounted On Four 50 Mm Swivel Castors. •Fitted With Stainless Steel Pillar Height Adjustable With Pneumatic Pump • Operated By Clip Provided On Back Side Of Pillar. •Size: 32 L X 16 W X 32-42 H. •Finish: Pre-Treated & Epoxy Powder Coated Base With Stainless Steel Pillar. • Certification- Iso 13485:2016, Iso 14001:2015, Gmp, Iso 50001, Iso 45001 , Sanitizer Machine • Product Type : Fogger Machine • Voltage : 220V • Phase : Single Phase • Wattage : 1000 Watt • Rpm : 2000 Rpm • Discharge Capacity : 5-25 Ltr/Hour • Liquid Particle Size : 15-50Um • Spray Distance : 15M • Tank Capacity : 4 Litre • Cable Requirement : 3 Core Flexible Cable • Certification- Iso 13485:2016, Iso 14001:2015, Gmp, Iso 50001, Iso 45001
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
22.
Educational and Research Institute #10212966 Price Bid
Lecture Capture Studio , 4K Ptz Camera • Sensor - 1.0 Inch-Type Cmos • 15X Optical Zoom, 20X Digital Zoom • Effective Pixels Approx. 8.29 Megapixels (3840 X 2160) • Lens - F=8.3 – 124.5 Mm, F/2.8 – 4.5, 15X Optical Zoom, 9-Bladed Iris Diaphragm • Focal Length F=8.3 – 124.5 Mm, F/2.8 – 4.5, 35Mm Equivalent Focal Length: Approx. 25.5 (W) – 382.5 Mm (T) • Angle Of View Horizontal: 73.0 (W) – 5.7° (T) Vertical: 45.2° (W) – 3.2° (T) • Min. Illumination - 1.5 Lux At Uhd • Shutter Speed 1/3 – 1/2000 Sec • Gain = -6.0 Db~ 33.0 Db • Nd Filter - Built-In (Off, 1/4, 1/16, 1/64), Motor Operated • Focus - Focus Mode: Manual, Af-Boosted Mf, Continuous Af, Face Af, Tracking Af Type: Dual Pixel Cmos Af, Contrast Af • Gamma - Normal1 (Standard), Normal2 (X4.0), Normal3 (Bt.709), Normal4 (X5.0), Wide Dr, Oem Log 3 • Pan And Tilt - Pan Operation Range: Horizontal ±170° Pan Operation Speed: 0.1° – 100°/Sec. Tilt Operation Range: Vertical -30° – +90° Tilt Operation Speed: 0.1° – 100°/Sec. • Protocol -Xc, Rtsp/Rtp, Ndi|Hx, Rtmp/Rtmps, Standard Communication (Serial), Standard Communication (Ip), Srt, Freed • Video Output Format: Sdi - 1920 X 1080: 59.94P/59.94I, 50.00P/50.00I/25.00P, 29.97P/23.98P (4:2:2 10 Bit)1280 X 720: 59.94P, 50.00P (4:2:2 10 Bit) • Video Output Format: Hdmi 3840 X 2160: 29.97P, 25.00P, 23.98P (4:2:2 10 Bit) 1920 X 1080: 59.94P/59.94I, 50.00P/50.00I/25.00P, 29.97P/23.98P (4:2:2 10 Bit) 1280 X 720: 59.94P, 50.00P (4:2:2 10 Bit) • Video Output Format: Ip 3840 X 2160: 29.97 Fps, 14.99 Fps, 5.00 Fps (4:2:0 8 Bit) 1920 X 1080: 59.94 Fps, 29.97 Fps, 14.99 Fps, 5.00 Fps (4:2:0 8 Bit) 1280 X 720: 59.94 Fps, 29.97 Fps, 14.99 Fps, 5.00 Fps (4:2:0 8 Bit) 640 X 360: 59.94 Fps, 29.97 Fps, 14.99 Fps, 5.00 Fps (4:2:0 8 Bit) • Gen-Lock Terminal - Bnc Jack X 1, 1.0 Vp-P/75 O, Input Only • Audio Input- 2X Xlr/Audio Input (3-Pin Jack)Balanced Sensitivity (Mic): -60 Dbu Sensitivity (Line): +4 Dbu , 4K Ptz Camera • Sensor – ½.5”Inch-Type Cmos Sensor Or Better • 20X Optical Zoom, 20X Digital Zoom • Effective Pixels Approx. 8.29 Megapixels (3840 X 2160) • Lens - F=3.67 – 73.4 Mm, F/1.8 – 2.8, F/2.8 – 4.5, 15X Optical Zoom, 9-Bladed Iris Diaphragm • F=3.67 – 73.4 Mm, F/1.8 – 2.8, 20X Optical Zoom, 8-Bladed Circular Aperture 35Mm Equivalent Focal Length: [4K Uhd] Approx. 29.3 (W) – 601 Mm (T) [Full Hd] Approx. 30.5 (W) – 627 Mm • Focus - Focus Mode: Manual, Af-Boosted Mf, Continuous Af, Face Af, Tracking Af Type: Dual Pixel Cmos Af, Contrast Af • Gamma - Normal1 (Standard), Normal2 (X4.0), Normal3 (Bt.709), Normal4 (X5.0), Wide Dr, Oem Log 3 • Pan And Tilt - Pan Operation Range: Horizontal ±170° Pan Operation Speed: 0.1° – 100°/Sec. Tilt Operation Range: Vertical -30° – +90° Tilt Operation Speed: 0.1° – 100°/Sec. • Protocol -Xc, Rtsp/Rtp, Ndi|Hx, Rtmp/Rtmps, Standard Communication (Serial), Standard Communication (Ip), Srt, • Video Output Format: Sdi - 1920 X 1080: 59.94P/59.94I, 50.00P/50.00I/25.00P, 29.97P/23.98P (4:2:2 10 Bit)1280 X 720: 59.94P, 50.00P (4:2:2 10 Bit) • Video Output Format: Hdmi 3840 X 2160: 29.97P, 25.00P, 23.98P (4:2:2 10 Bit) 1920 X 1080: 59.94P/59.94I, 50.00P/50.00I/25.00P, 29.97P/23.98P (4:2:2 10 Bit) 1280 X 720: 59.94P, 50.00P (4:2:2 10 Bit) • Video Output Format: Ip 3840 X 2160: 29.97 Fps, 14.99 Fps, 5.00 Fps (4:2:0 8 Bit) 1920 X 1080: 59.94 Fps, 29.97 Fps, 14.99 Fps, 5.00 Fps (4:2:0 8 Bit) 1280 X 720: 59.94 Fps, 29.97 Fps, 14.99 Fps, 5.00 Fps (4:2:0 8 Bit) 640 X 360: 59.94 Fps, 29.97 Fps, 14.99 Fps, 5.00 Fps (4:2:0 8 Bit) • Gen-Lock Terminal - Bnc Jack X 1, 1.0 Vp-P/75 O, Input Only • Audio Input- 2X Xlr/Audio Input (3-Pin Jack)Balanced Sensitivity (Mic): -60 Dbu Sensitivity (Line): +4 Dbu , Ptz Camera Control Number Of Camera Groups - 10 Groups With Up To 10 Cameras Per Group • Maximum Number Of Connected Cameras – 100 • Ptz Camera Remote Controller Compatible With Above Camera And From Same Oem • Appoint Up To 100 Pre-Set Angles Per Camera Using The 17.78Cm Touchscreen • A Multi-Function Joystick Allows Precise Adjustment Over Camera Movements And Settings While A Control Grip On Top Of The Stick Allows Zoom, Focus And Iris Control. • Display Lcd 7 Touch Screen Displays Menus & Key Camera , Camera Support System • Type: Professional Tripod System (With Fluid Head) • Maximum Load Capacity: 7 Kg (15.4 Lbs) • Height Range: Minimum Height: 70 Cm (27.6 Inches) Or Lower Maximum Height: 160 Cm (62.99 Inches) Or Higher • Leg Sections: 3 Sections Per Leg • Leg Lock Type: Twist-Lock System • Material: Aluminum Alloy (Tripod Legs), • Head Type: Fluid Head • Tilt Range: +90° To -75° Or Better • Pan Range: 360° Pan • Counterbalance System: Yes (With Adjustable Counterbalance) • Pan & Tilt Drag: Adjustable For Smooth Movements • Mounting Plate: 75Mm Ball Base For Easy Leveling And Support • Quick Release Plate: Yes (Compatible With Quick-Release Systems) • Leg Tip Type: Rubber Or Spiked Feet, Adjustable • Leveling System: Built-In Bubble Level For Accurate Leveling Additional Features: • High Stability For Professional Video Shooting • Smooth Fluid Head For Stable Panning And Tilting • Lightweight And Portable For Field Use • Durable, Ideal For Both Indoor And Outdoor Shooting Environments , Dolly For Tripod • Type: Professional Camera Dolly System • Compatibility: Compatible With Most Tripods, Especially With The Above Tripod • Maximum Load Capacity: 30 Kg Or Higher • Dolly Base Dimensions: 65 Cm X 82 Cm (25.6 X 32.3) • Leg Length Adjustment: Adjustable Leg Lengths To Suit Different Tripod Heights • Wheel Type: Durable Rubber Wheels (With Ball Bearings) • Wheel Locking System: Yes (Individual Wheel Locks For Stability) • Wheel Size: Large Wheels For Smooth Movement Over Different Surfaces • Wheel Rotation: 360° Rotation For Flexible Movement , Video Production Switcher Hand Carry Switcher- 6-Ch Hd Portable Video Streaming Studio (1080I/720P) Hand-Carry Portable Production Unit, Designed As A Suitcase Providing; 6-Ch Hd Input Digital Video Switcher W/ Xpt Assignment, Ftb, Mix, Cut, Wipe Effects,Pip & 2X Dsk, Tally/Gpi Output, With A Built-In 17.3” Fhd Monitor And A H.264 Streaming Encoder And Recorder For Simultaneously Live Streaming & Recording. 6 Video Input: 4X Hd-Sdi + 2X Hdmi5 Video Output: 2 X Sdi (Aux/Pvw/Pgm/Pgm Clean), 3X Hdmi (Pgm) , File Based Full Hd Video Recorder / Player Professionalssd 3G Video Recorder With 2 X 2.5 Ssd Slot / 2 X Sdxc Card Slot / 1 X 3G Sdi Input With Loop Output / 2 X 3G Sdi Output / 1 X Hdmi Input / 1 X Hdmi Output / Ethernet 10G Port For Deck Control And Fast File Transfer / 1 X Usb Type-C 3.0 (Up To 5Gb/S) For External Drive Recording, Webcam Out, Software Configuration Andupdates. To Be Quoted With Compatible2 X 1Tb Ssd Drives And Compatible Reader. , Wireless Lapel Microphone –Dual Transmitter Single Receiver Transmitter Wireless Mode Operating Frequency 2.400-2.4835 Ghz Bluetooth Protocol Br/Edr Bluetooth Operating Frequency 2.400-2.4835 Ghz Battery Capacity 360 Mah Battery Energy 1.39 Wh Battery Voltage 3.87 V Operating Time 6 Hours Receiver Dimensions 54.20×28.36×22.49 Mm (L×W×H) Operating Frequency 2.400-2.4835 Ghz Battery Type Li-Ion Battery Capacity 360 Mah Battery Energy 1.39 Wh Battery Voltage 3.87 V Charging Specification Max 5 V Charging Time 70 Mins Operating Time 6 Hours Transmitting Distance: 100 Meters , Wireless Handheld Microphone • Digital Transmission: Operating In The Uhf Spectrum, Enhancing Range, Reliability, And Scalability. • Smart Assist App: Connects Via Bluetooth Low Energy For Streamlined Setup And Operation. • Auto Scan: Creates Reliable Connections With Minimal Time And Effort. • Audio Input Dynamic Range: 134 Db, Eliminating The Need For Sensitivity Adjustments. • Equidistant Tuning Grid: Channels Can Be Placed 600 Khz Apart, Simplifying Frequency Coordination. • Tuning Bandwidth: 56 Mhz, Enabling Up To 90 Channels. • Selectable Frequencies: 2,240 Allow For Fine Tuning. • Battery Life: Up To 12 Hours With A Lithium-Ion Battery Pack, Or Up To 8 Hours With 2X Aa Batteries. • Audio Frequency Response: 20 Hz - 20 Khz (-3 Db) @ 3 Dbfs, 50 To 18,000 Hz • Frequency Response: 50 To 18,000 Hz • Polar Pattern: Cardioid. • Transducer Principle: Dynamic. • Max. Sound Pressure Level: 130 Db. • Dynamic Range: >134 Db. • Equivalent Noise Level: 32 Db. • Audio Output Level: 18 Dbu Max • Connectors: 3.5Mm, 6.35Mm (1/4-Inch) Output, Xlr Out , Pen Tablet Display 24 (+ Or – 1”)Uhd Resolution 3840X2160@60Hz Pro Pen 2, 10 Point Multi Touch, Battery Free Stylus Pro Pen 3, 8 Express Keys, 12 Ms Response Time, Brightness 300 Cd/M2 , Computer System For Interactive Display • Processor – Latest Generation I5 Processor Or Better • Ram- Min 16 Gb Or Better • Storage – 500Gb Ssd Or Better • Graphics Card – 2Gb Min. Or Better • Display – 19.5” Or Higher • Peripherals – Keyboard And Mouse • Os – Windows Os , 100W Led Panel Light • 100W Led Soft Panel Light • 5600K Colour Temperature. Cri,Tlci And R9 Value Above 95. • Uniform Shadowless Output, No Heat From Light, No Uv Radiation, • Control Mode:- Manual And Dmx Control Mode Through 5Pin Xlr. • Extreme Soft Illumination With Diffuser. • 0 ~ 100% Linear Dimming. • Black Powder Coated Fabricated Housing With Normal Yoke But With Barndoor And Safety Chain. • Light Fixture Mounting Clamp Customized For Suspending On Fixed Bars On Stage Made Up Of Aluminium Or Ms Material Complete With Black Powder Coating Matt Black Finish. With Spud. , Ceremic Green Or White Board • 12X4 Feet Resin Coated Ceramic Green/ White Board For Class • Room With Chalk And Duster Holder. • The Board Should Be Suitable For Academic Purpose And 1 • Framed In Double Sided Curved Anodized And Chrome • Plated Abs Corners For Good Aesthetics And Longevity. • To Be Covered With Pelmut With Lighting , Motorized Chroma Screen • Motorized Screen For A Dimension Of 9 Ft W X 9 Ft H • Having Easy Remote-Control Option To Move The Screen, • Uniform Noiseless Movement With Required Mounting Arrangement With No Frills Or Folds During Continuous Operation , 75-Inch Professional Display. Display Panel: • Screen Size: 189.3 Cm Diagonal • Aspect Ratio: 16:9 • Resolution: 3840 X 2160 (Uhd) • Panel Technology: Ips With Direct Led Backlighting • Brightness: 500 Cd/M² • Viewing Angle: 178° Horizontal And Vertical • Operation Hours: 24/7 Connectivity: • Hdmi Inputs: 4 Hdmi Ports • Usb Inputs: 4 Usb Ports (2 Usb 2.0, 1 Usb 2.0 Internal, 1 Type-C) • Displayport Input: 1 Dp 1.2A • Displayport Output: 1 Dp 1.2A • Rf Input: 1 Side • Av Input: 1 Mini Av Side • Rj-45 (Ethernet): 1 Side • Spdif Out: Yes Supported Formats: • Picture Formats: Bmp, Png, Gif, Heif • Video Formats: Mpeg1/2/4, Xvid, H.263/264/265, Wmv, Vc1, Vp9, Rm, Avs, Sorenson, Motion Jpeg, Av1 • Audio Formats: Pcm, Amr, Lpcm, Ra, Mpeg1/2/4, Aac, Wma, Ac4, Eac3, Ms11, Ms12, Flac, Vorbis, Dolby Truehd, Dts Audio: • Output Power: 10W + 10W • Features: Dolby Audio Main Features: • Hotel Mode: Yes, Basic • Cec: Yes, Basic • Sound Out (Arc): Yes • Hdr Support: Hdr10, Hlg • Bluetooth: Yes • Wi-Fi: 802.11A/B/G/N/Ac, 2.4Ghz/5Ghz, Built-In System On Chip (Soc) Specifications: • Cpu: Cortex-A55 X4, 1.3Ghz • Gpu: Mali G31 Mp2, Open Gl Es3.2 • Operating System: Android Tv R - 11.0 • Memory: 16Gb Emmc Storage, 2Gb Ddr3 Ram , 21 Broadcast Display Display Panel: • Screen Size: 21.5 Inches • Resolution: 1920 X 1080 (Full Hd) • Aspect Ratio: 16:9 • Brightness: 250 Cd/M² • Contrast Ratio: 1000:1 • Color Depth: 8-Bit (16.7 Million Colors) • Viewing Angle: 178° Horizontal And Vertical • Response Time: 7 Ms Connectivity: • Video Inputs: O 2 X 3G-Sdi Bnc O 1 X Hdmi 1.3 (Optional) • Video Output: O 1 X 3G-Sdi Bnc • Audio: O 16-Channel Audio Meters (Up To 8 Channels Displayed Simultaneously) O 2 X 8O/2W Speakers (Rear-Mounted) O 3.5Mm Headphone Jack O Sdi Embedded Audio Support Supported Video Formats: • Hdmi: O 480P/60, 480I/60, 576I/50, 576P/50 O 720P/50/60 O 1080I/50/60 O 1080P/24/25/30/50/60 • 3G-Sdi: O 1080P (50/60) • Hd-Sdi: O 1080I (60/59.94/50) O 1080P (30/29.97/25/24/24Sf/23.98/23.98Sf) O 720P (60/59.94/50/30/29/25/24/23.98) • Sd-Sdi: O 480/59.94I, 576/50I Additional Features: • 3D Lut Loading For Color Calibration • False Color For Exposure Analysis • Zebra Pattern For Highlight Indication • Waveform And Vector Scope For Signal Analysis • Audio Level Meters • Safety Markers And Aspect Ratio Markers • Gpi Control • User-Defined Shortcut Keys , Audio Mixer 10-Channel Analog Mixer With Built-In Usb Audio Interface And Spx Digital Effects, Inputs: • 4 X Mic/Line (Xlr/Trs Combo) • 3 X Stereo Line (1/4 Trs, Rca) Outputs: • 2 X Main Out (Xlr, Balanced) • 2 X Monitor Out (1/4 Trs, Balanced) • 1 X Headphone Out (1/4 Trs) • 1 X Fx Send (1/4) Usb Audio Interface: • 2-In/2-Out (24-Bit/192Khz) • Compatible With Mac, Windows, Ios (With Adapter) Input & Processing: • Preamps: Class-A Mic Preamps • Phantom Power: +48V (For Condenser Mics) • Eq: 3-Band Eq (High, Mid, Low) On Mic/Line Inputs • Compression: 1-Knob Compressor On Channels 1-2 • High-Pass Filter: 80Hz On Mic Inputs Usb Interface For Daw Recording And Streaming , Speakers 2-Way, Bass-Reflex Surface-Mount Speaker Speaker Type:2-Way, Bass-Reflex Components: • Low-Frequency Driver: 8 Cone • High-Frequency Driver: 1 Soft Dome Tweeter Frequency Response: • -10 Db: 51 Hz – 20 Khz Coverage Angle: • Horizontal: 100° • Vertical: 100° Power Handling: • Noise: 90W • Program: 180W • Maximum: 360W Sensitivity: • 91 Db Spl (1W, 1M) Maximum Spl: • 117 Db Spl (Calculated, 1M) Impedance: • 8O Transformer Taps (For 70V And 100V Systems): • 100V: 60W (170O), 30W (330O), 15W (670O) • 70V: 60W (83O), 30W (170O), 15W (330O), 7.5W (670O) Crossover Frequency: • 2.8 Khz , Amplifier 2-Channel Power Amplifier Designed For Professional Audio Applications, Offering High Output Power And Advanced Processing Capabilities. Below Are Its General Specifications: Amplifier Type: • Class-D Amplifier With Custom Lsi Chip Power Output: • Stereo Mode: O 8O: 300W Per Channel O 4O: 500W Per Channel O 2O: 300W Per Channel • Bridged Mode: O 8O: 600W O 4O: 1000W Frequency Response: • ±1.0 Db (1W, 8O, 20Hz To 20Khz) Total Harmonic Distortion (Thd): • 0.1% At 1Khz, 10W • 0.3% At 1Khz, Half Power Signal-To-Noise Ratio (Snr): • 101 Db (A-Weighted, 8O, Gain Setting = +14Dbu) Crosstalk: • Less Than -60 Db (Half Power, 8O, 1Khz, Volume Max Input 150O Shunt) Inputs: • 2 X Xlr • 2 X 1/4 Trs Outputs: • 2 X Speak On Nl4 • 2 X Binding Post • 2 X 1/4 Ts Cooling System: • Dual 16-Step Variable Speed Fans With Front-To-Rear Airflow Digital Signal Processing (Dsp): • Onboard Eq, Limiting, Delay, Crossovers (Saved Via Usb Type A Port) , Hdmi Splitter • Video Input/Output - Input: 1 X Hdmi, Output: 4 X Hdmi • Video Format Hdmi Supported Resolutions 4096X2160p60/59.94/50 4096X2160p30/29.97/25/24/23.98 3840X2160p60/59.94/50 3840X2160p30/29.97/25/24/23.98 1080P60/59.94/50, 1080P30/29.97/25/24/23.98 1080I60/59.94/50, , 720P60/59.94/50 480P, 576P, 480I, 576I Pc Supported Resolutions 640X480@60Hz, 800X600@60Hz, 1024X768@60Hz, 1280X720@60Hz, , 1280X768@60Hz, 1280X960@60Hz, 1280X1024@60Hz, 1360X768@ 60Hz, 1366X768@60Hz, 1400X1050@60Hz, 1680X1200@60Hz, 1920X1080@60Hz, 1920X1200@60Hz Video Processing Hdr 4K2k@60 4:2:0 10Bits 4K2k 60Hz Ycbcr4:4:4 8Bit/Ycbcr4:2:0 10Bit 4K2k 30Hz Ycbcr4:4:4 8Bit Video Bandwidth - Single-Link 600Mhz (18Gbps) Audio Format -Dts-Hd Master Audio, Dolby Truehd, Dolby Digital, Dts, Dvd-Audio, Lpcm, Sacd, Mpcm , Up/Down/Cross Converetr • Type - Up/Down/Cross Conversion • Input -Vga X 1, Hdmi X 1 , Hd/Sd-Sdi X 1 Or Better • Output - Sdi X 2, Hdmi X 1, Sdi Loop Thru Bnc Or Better • Supported Video Output Formats:1080P60/59.94/50, 1080P30/29.97/25/24/23.98, 1080I60/59.94/50, 720P60/59.94/50, 525I, 625I • Audio Format (Input):Analog Audio L/R: Stereo Audio • Sdi / Hdmi Embedded Audio • Audio Format (Output):Sdi Embedded Audio Up To 8Ch, 48Khz, Pcm Audio • Hdmi Embedded Audio Up To 8Ch, 48Khz, Pcm Audio , Bidirectional Sdi – Hdmi Converter • Sdi Video Inputs -1 X Sd, Hd Or 3G-Sdi. • Sdi Video Outputs - Automatically Matches The Hdmi Video Input. • Hdmi Video Inputs - Hdmi Type A In. • Hdmi Outputs - Hdmi Type A Out. • Multi Rate Support - Auto Detection Of Sd Or Hd • Psu , Usb Capture Device • Input Interface - One Sd/Hd/3G Sdi Input + Embedded Audio • Support Input Resolution Up To 2048×1080 Pixels • Host Interface - Usb 3.0, Compatible With Usb 2.0 • Os Support - Windows, Linux, Mac, Chrome Os • Capture Format - Support Capture Resolutions Up To 2048X1080 • Support Capture Frame Rates Up To 120Fps • Support 2-Channel Audio Streams • Capture Sdi Signals Transmitted A Long Distance Away: Up To 150M For 3G-Sdi Signals • Included Software - Usb Capture Utility, Capture Express, Etc. • Compatible Software Zoom Rooms, Microsoft Teams Rooms, Skype For Business, Google Hangouts, Gotomeeting, Vlc, Obs Studio, Xsplit, Etc. • Auto Detection Of Input Signal Format • Windows, Linux And Mac Sdk • Continuously Work For 24Hx7 • Led Status Indicator , Professional Headphone • Type: Over-Ear, Closed-Back Headphones • Frequency Response: 8 Hz - 25,000 Hz • Impedance: 64 Ohms • Sensitivity: 113 Db (At 1 Khz) • Max Spl (Sound Pressure Level): 113 Db • Driver Type: Dynamic, Neodymium • Total Harmonic Distortion (Thd): <0.1% (At 1 Khz, 100 Db Spl) • Cable Length: 3 Meters (Detachable Coiled Cable) • Connector: 3.5 Mm Stereo Jack With 1/4 (6.3Mm) Adapter , Installation Materialincluding Branded Video Cables, Audio Cables, Convertor, Connectors, Rack And Otherinstallation Materials. , Installation And Integration Charges. Preferred Concealed Cabling ,The Installation Should Be Executed By Professionals And Verified By Oems Authorized Personnel , Workstation - I9 13900/32Gb/512Ssd/4Tb Hdd/T400-4Gb/Win11 Pro With 27 S2722qc - 4K Monitor , Warranty: Minimum Three Years For Equipment And Installation Services
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
23.
Housing Urban and Rular Development #10204751 Price Bid
Tender For Lake Front Development At Porur Chennai.; 1 CIVIL WORKS 2 Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. 3 Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification. 4 Clearing Scrub Jungle, etc., complete complying with standard specification and as directed by the departmental officers. 5 Installation of Vertical Bored cast in situ RCC piles of 300 mm diameter and M-30 grade of concrete in all types of soils, using Standardised Concrete Mix of following grade, with sulphate resistant Cement or OPC/PPC, etc and Crushed Stone Sand and 20mm and down graded HBGS jelly coarse aggregate. The rate includes cost for placing of reinforcement cage in bore hole in correct position, cost of boring to the required depth with Bentonite solution with temprory casing of required length, conveyance of RMC to site and pouring concrete using Tremine pipes, conveyance of all materials to the site including all tools and plants, shifting the plants and equipments from one point to another, excavtion of mud pits for circulation of Bentonite soultion, closing the mud pits to original level and mud removal with initial lead and lift but including dismantling the concrete above the cut off level etc complete as directed by the departmental officers including socketing. The reinforcement cage should be welded properly for lifting. The concrete cubes to be tested as per IS 456-2000. Acceptance criteria by clause 16.1. Frequency of testing as per 15.2.2. Testing to be conducted at both the ends at site as well as RMC plant. Pile driving depth should be decided by the departmental officers at site. The length of pile for payment shall be measured from top of shoe to the bottom of the pile cap. (Cost of Reinforcement provided for Pile and Welding charges shall be measured and Paid separately) 6 Installation of Vertical Bored cast in situ RCC piles of 380 mm diameter and M-30 grade of concrete in all types of soils, using Standardised Concrete Mix of following grade, with sulphate resistant Cement or OPC/PPC, etc and Crushed Stone Sand and 20mm and down graded HBGS jelly coarse aggregate. The rate includes cost for placing of reinforcement cage in bore hole in correct position, cost of boring to the required depth with Bentonite solution with temprory casing of required length, conveyance of RMC to site and pouring concrete using Tremine pipes, conveyance of all materials to the site including all tools and plants, shifting the plants and equipments from one point to another, excavtion of mud pits for circulation of Bentonite soultion, closing the mud pits to original level and mud removal with initial lead and lift but including dismantling the concrete above the cut off level etc complete as directed by the departmental officers including socketing. The reinforcement cage should be welded properly for lifting. The concrete cubes to be tested as per IS 456-2000. Acceptance criteria by clause 16.1. Frequency of testing as per 15.2.2. Testing to be conducted at both the ends at site as well as RMC plant. Pile driving depth should be decided by the departmental officers at site. The length of pile for payment shall be measured from top of shoe to the bottom of the pile cap. (Cost of Reinforcement provided for Pile and Welding charges shall be measured and Paid separately) 7 Installation of Vertical Bored cast in situ RCC piles of 450 mm diameter and M-30 grade of concrete in all types of soils, using Standardised Concrete Mix of following grade, with sulphate resistant Cement or OPC/PPC, etc and Crushed Stone Sand and 20mm and down graded HBGS jelly coarse aggregate. The rate includes cost for placing of reinforcement cage in bore hole in correct position, cost of boring to the required depth with Bentonite solution with temprory casing of required length, conveyance of RMC to site and pouring concrete using Tremine pipes, conveyance of all materials to the site including all tools and plants, shifting the plants and equipments from one point to another, excavtion of mud pits for circulation of Bentonite soultion, closing the mud pits to original level and mud removal with initial lead and lift but including dismantling the concrete above the cut off level etc complete as directed by the departmental officers including socketing. The reinforcement cage should be welded properly for lifting. The concrete cubes to be tested as per IS 456-2000. Acceptance criteria by clause 16.1. Frequency of testing as per 15.2.2. Testing to be conducted at both the ends at site as well as RMC plant. Pile driving depth should be decided by the departmental officers at site. The length of pile for payment shall be measured from top of shoe to the bottom of the pile cap. (Cost of Reinforcement provided for Pile and Welding charges shall be measured and Paid separately) 8 Refilling with excavated earth in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification. 9 Supplying and filling with earth up to 10 Km for foundation and basement, etc., including watering and consolidating, etc., complete complying with standard specifications and as directed by the engineer-in-charge 10 Supplying and filling in foundation, basement, etc with Stone Dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 11 Supplying and filling in foundation, basement, etc with Crushed Stone sand filling in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 12 Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 13 Plain Cement Concrete 1:2:4 (one part of cement, two part of Crushed Stone Sand (M- Sand) and four part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 14 Construction of Granular sub-base of required compacted thickness by providing laying, spreading and compacting of Close graded Material conforming to Grading V of Table 400-1 of MORTH clause 401,mixing in a Wet Mix Plant of 200 tonne capacity at OMC, carriage of mixed material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory roller 8-10 tonne to achieve the desired density of 98% including protection of edges of GSB layer, cost of all materials, labour, hire charges of machinery, lighting, guarding, barricading, maintenance of diversion road, loading & unloading, all lead and lift etc., to achieve minimum CBR value of 30%(Compacted Thickness) in accordance with MORT&H technical specification clause No. 401 and with all other incidental charges and as per the direction of the Engineer-In-Charge of work. 15 Damp proof course with Cement Mortar 1:4 (One Cement and Four sand) 12mm thick mixed with best approved quality water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used and finishing, curing etc. complete complying with standard specification. 16 Providing Anti-termite treatment to soil adjecent and under building foundation, plinth periphery of the building by application of chemicals of IS 63613 part I to IV in stages to suit the progress of work consist as per the detailed specification as below.Including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing etc., complete and as directed by the departmental officers. 17 Random Rubble masonry in Cement Mortar (1:3) etc., Complete complying with standard specification and as directed by the Departmental Officers 18 Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid). 19 Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid). 20 For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc. 21 For plane surfaces such asrectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc. 22 For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc. 23 Centering for curved surfaces of all RCC items of work 24 Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part there of but not less than 30 cm, over the initial 3.00 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the department officers. 25 Providing and laying in position, Standardised Concrete Mix M-25 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kg/mᶾ and maximum water cement ratio of 0.50, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers.The coarse and fine aggregates to be used should comply with the requirements of IS Standards.(No separate payment will be made by the Department for the excess usage of materials). 26 Foundation and Basement 27 For Ground Floor 28 For First Floor 29 Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 400 kg/mᶾ and maximum water cement ratio of 0.45, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers.The coarse and fine aggregates to be used should comply with the requirements of IS Standards.(No separate payment will be made by the Department for the excess usage of materials). 30 Foundation and Basement 31 Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) 32 Brick work in Cement Mortar 1:3 using best quality of Second Class Ground Moulded Chamber Burnt Bricks 9 x 4-3/8 x 2-3/4 for foundation and basement including curing, etc., complete complying with standard specifiction. 33 For foundation & basement 34 In Ground floor 35 In First floor 36 Brick partition walls of 11.50cm thickness using best quality II Class Ground Chamber Burnt Bricks of size 9 x 4-3/8 x 2-3/4 in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately). 37 Ground floor 38 Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. 39 Inner Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. 40 Outer Plastering with Cement Mortar 1:4 (One cement and Four sand), 20mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. 41 Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers. 42 Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush.Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed.Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete. 43 White washing two coats with freshly burnt white shell lime in all floors including cost of lime, blue powder fevicol type gum, brushes, scaffolding charges, etc., complete complying with standard specification and as directed. 44 Supplying and painting the walls with two coats of wall putty as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications and as directed by the departmental officers. (The wall putty shall be got approved by the Executive Engineer before use of work). 45 Painting newly plastered wall surface with two coats of ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. Interior painting 46 Painting two coats of newly plastered wall surface with ready mixed Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. 47 Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) 48 Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) 49 Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers. 50 Flooring with first quality design ceramic tiles of all colours of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand)base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) 51 Paving the floor with best quality Double Charged Vetrified Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three M-sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification.(The make and brand of the tiles should be Johnson / Kajaria / Somany / Nitco / RAK which has to be got approved by Executive Engineer before use on works). 52 Providing And Fixing Machine Dressed Grey Granite Slab All Sides Machine Cut of Size 0.60 M X 0.60 M Size And 50 mm Thick Granite Slabs For Platform(Pavement) Including Cost And Conveyance ofGranite From Available Source Including Labour Charges For Fixing the Slab In Position To The LineLevel And GradientIncludingPointing With cm.1:3 And All Other Incidental Charges Etc.Complete 53 Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise andsimilar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification. 54 Paving the floor with Cement based Hydraulically pressed Anti skid tiles (pattern design) - 20 mm thick (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works). 55 Dadooing walls with Colour designed digital print ceramic tiles, with borders, with size of 300mm x 450mm x 8mm and above set in Cement Mortar 1:2 (One Cement and Two M-sand)10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. nbatly in all floors, curing, etc,,complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be like Johnson / Kajaria / Somany / Nitco / RAK or Equivalent which has to be got approved by Executive Engineer before use on works). 56 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between.The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete.The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete 57 Nosing the granite slab - single nosing as directed by the engineer-in-charge 58 Grooving the granite slab as directed by the engineer-in-charge 59 Manufacturing, supply & fixing of precast kerb stone of size 400mmx259mmx200mm thick made of M 20 grade of concrete rectangular in shape with one corner chamfered by 100 mm x 100 mm as per approved design i/c cost of all material, labour and curing etc., complete. as per IRC 5758 - 1984. 60 Supplying and laying hydraulic pressed monolithic natural grey colour cement concrete inter locking paver block of 63mm thick, in cement concrete 1:2:4 (one cement, two sand, four aggregate) using difference design and with stand for pressure of 150 - 200 kg/m2 over the existing sand cushion by using earth rambers and also vibratting the concrete blocks often laying using plate vibrators etc, complete as directed by the departmental officers. 61 Supplying and fixing of M.S.grill of approved design for grill gate, grill work to doors and windows openings ramp etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including priming coat of best approved quality red oxide primer etc., complete complying with standard specification. 62 UPVC Window Specification:Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle.The corners and joints should be welded and cleaned.Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong lockingsystems and as per size for arresting noise and energy loss.The connecting mechanism between sash and outer frame that enables opening of the window.The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames.The window should be got approved from the Executive Engineer before use on work 63 Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm.The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber.The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug. 64 ABS DOOR Specification:Providing and fixing of ABS (Acrolynitrile Butadiene Styrene) Door using factory made plain FPVC (Foamed Polyvinyl Chloride) door frame of the size 105 x 40mm with a wall thickness of 10mm made out of extruded rigid FPVC profile mitre joined with 10 Nos. of 50mm long screw.The door frame shall be fixed to the wall by using 80mm long screws through the frame with the help of PVC fasteners to be provided for each vertical member, stiffeners of (‘U’ Channel of size 29 x 9 x 1mm, 150mm long) 3 Nos. at hinge point, frame reinforcement of (‘U’ GI Channel of size 46 x 22 x 0.06mm), bottom tie rod of (‘U’ GI Channel size of 15 x 15 x 1mm), the ABS Shutter of 35mm thick factory made plain pre-laminated.ABS (Acrolynitrile Butadiene Styrene) door shutter moulded in different designs, consisting of all round Frame made out of water proof solid foam PVC bar of size 20x32mm, reinforced by 32 x 32mm - 2 Nos. for vertical made out of LVL (Laminated Veneer Lumber), core material of 32mm thick high density craft paper honey comb board, sandwiched on both sides with pre-laminated ABS sheet thickness of 1.5mm.PVC edge banding of size 0.45mm on the vertical sides.Hardware made out of ball bearingbutterfly hinges - 3 Nos. for each shutter and ISI make SS round lock complete, including cost of Materials, conveyance and all other incidental charges and labour charges for fixing the Door neatly etc., complete complying with the standard specification. The door shutter and frame should be got approved from the Executive Engineer before use on workPlain Pre-laminated Door 65 Fabrication supply and fixing in position of aluminium natural colour matt finish louvered ventilator in all floors made with extruded aluminium section of following size with necessary accessories such as rubber beading, best quality of handle including supplying and fixing of 4 mm thick plain glass including cost of all materials, labour power consumption required for fabrication drilling holes in RCC column/floor slab/ masonry wall wherever necessary with power drills to the required extent and making good to the original condition after fixing etc., and as directed by the departmental officers etc. complete.The aluminium frames to be anodised under electrically controlled condition in accordance with ISI 1868/ 1962 specification for an average anodic film thickness of not less 15 microns and all the materials should be got approved by the Executive Engineer before use on work. Outer frame alround section of size 62x38x2mm @ 1.174 kg/ m vertical louvered section of size 60x30x4mm @ 1.27 kg/m and aluminium clips of size 19.05x10.27/11.05x1.20mm @ 0.169 kg/m. 66 Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification 67 Roofing with best quality prelaminated Polycarbonate Sheet 6mm thick of approved colour design and quality including cost of self tapping screws between washer and cutting the sheet to required slope if found necessary during execution of work, including charges for machine etc., complete, as directed by the engineer-in-charge 68 Supplying and fixing of Exterior WPC louvered panel for cladding and roofing works with material specifications: Material - WPC, Size - 2900 x 200 mm, Design exterior decorative panel, Color - Brown, Usage/Application for all kinds of exterior work, Thickness - 26mm, Core Filling - Fly Ash, Packaging Type - fully packed, etc., complete as directed by the engineer-in-charge 69 Supplying and Fixing ofCNC cut perforated Enclosure for EB transformer and EB pillar Boxes by using CNCMS Sheet (2mm thick), doorhinged with vertical support of80X40 mm TubularPost including horizontal Support and Stiffener (40 x40 x2mm)for MS sheet including Powder coating ofall structural members and labor for fitting , welding andtransportation of thematerial from thefactory to Site as directed by the engineer - in charge. 70 Providing and fixing of Aluminium Composite Panel (ACP) 4 sided having 50 x 25 x 1.50mm frame work vertical and horizontals out of specially designed extruded sections withstand wind pressure of 180 Kg/sq.m and fabricated fixed at all level elevation and heights.The extruded section cutting and fixing required space extruded section shall be of 6063 and alloy of BSH 9 confirming T is – 63400 rate shall included to fix the main frame with necessary clamps, fasteners, bolt nuts etc.The main frame of extruded section shall be of 22843 & 22739 (H9) grade conforming to BS 4174 (or) IS 8147.Rate shall included 4mm thick ACP sheet (0.25 + 3.5 + 0.25) alstrong or equivalent fixing with spacer tape and the ACP sheet bounded with special type structural sealant of dow corning 789 or equivalent in dust free conditions the gaps between ACP sheet to be filed with whether sealant and backer rod or 12mm foam sheet to ensure water and air tightness in all complete complying with standard specification as directed by the departmental officer 71 Refixing of damaged cement concrete solid block masonry in CC 1:3:6 (One of cement, three of sand and six of course aggregate) using 6mm and below HBG stone jelly with compressive strength of 50 kg/cm2 in cement mortar 1:5 (one of cement and five of sand ) including curing and neat finish etc., complete complying with standard specification and as directed by the departmental officers at site of work 72 Supplying and fixing of cement concrete solid block masonry by using solid blocks of size 400x200x150mm confirming to IS 2145-1965 made in CC 1:3:6 (One of cement, three of sand and six of course aggregate) using 6mm and below HBG stone jelly with compressive strength of 50 kg/cm2 in cement mortar 1:5 (one of cement and five of sand ) including curing and neat finish etc., complete complying with standard specification and as directed by the departmental officers at site of work. 73 Supplying and providing chain link fence with RCC posts.The RCC postswill be of 2.5m c/c and of 2.75mheight.The post will be 100mm square at top and 150mm square at bottom 2.15m height above ground level and 0.60m below ground level, in R.C.C 1:1.5:3mix using 12 to 20mm gauge stone jelly with necessary reinforcement moulding work and rendering smooth with cement at 15kg/cu.m etc., complete and fixed in c.c. foundation in 1:4:8 using 40mm size stone jelly. The foundation is of size 45x45x90 with sand filling 15cm height. The fencing will be of chain link 75mm size, 10 gauge. The height of fence is 2.0m after leaving 75mm gap from ground level including fixing the fence with the posts using G.I binding wire, etc. complet.ISI STD 74 Supplying and fixing Country wood scantlings for door, windows, joints, rafters, etc., or any other works using country wood scantlings in following lengh and complete it in all floors including labour charges for the manufacture of frames as per standard specification. 75 Country wood scantlings below 4m in length 76 Providing two legged Scaffolding using 15cm dia casurina post of 4m over all length (3m height + 0.5m Projection + 0.5m into the ground) the distance between the two rows being 1.25 and the spacing of posts being 2.0m in both the rows with two horizontal posts with 0.5m. Overlap on either side and braces at 2.0m centre to centre including longitudinal and transvers middle braces to step up and providing a platform with country wood planks of 40mm thick and 1m width, etc. in acomplete from using coil and nails - 1RM 77 For Initial height of 3.00 metre 78 For every additional height of 2.5 m above initial height of 3 m 79 Supply and fixing of 3-seater metal garden swing chair with canopy of material and specifications: Seating capacity - 3 seater swing, Material- metal, Appearance - modern with canopy, Cushion - Included, Usage/Application - balcony, garden, lounge, etc., Cushion material - polyster, etc., complete, as directed by the engineer-in-charge 80 Supplying,erectingandFixingprecast reinforcementbench with back rest. Bench shall consist of 2 nos. L shaped bases support in natural cement color of thickness 100mm, back height 1000mm, front height 450mm, base width 620mm and 5Nos Reinforced Concrete planks in red colorandsizeof 1500x100x50mm and 1no. reinforcedconcrete plank of 150x200x50mm: manufactured by using M-30 grade concrete & reinforced suitably: all parts to be joined with galvanized nuts and bolts of suitable size. 81 Supply & placing of FRP heavy duty three compartment Dustbin of size 1200 x 450 x 900 mm with top cover 82 Supply & placing of light weight concrete Dustbin of size 450 dia x 900 mm with top cover 83 Supply and placing of Monkey DustbinFRP – 2 Layers to a height of 3½ and width of 2½ 84 WATER SUPPLY AND SANITARY WORKS 85 Supplying and fixing in position best approved of BIS quality 110 mm dia PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of U clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification. 86 Supply and providingPriming Tank made up of PVC, Make: SINTEX / EQUIVALENT 87 Internal water supply - Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works. 88 For laying PVC pipes of dia 32mm 89 External Water Supply - Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works. 90 Above Ground Level 91 For laying PVC pipes of dia 40mm 92 Below ground level 93 For laying PVC pipes of dia 50mm 94 For laying PVC pipes of dia 40mm 95 For laying PVC pipes of dia 25mm 96 Supplying, laying and jointing CPVC pipes of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using CPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto etc., complete complying with standard specifications.The CPVC pipes shall be got approved by Executive Engineer before use on works.(Above Ground Level) (Internal Water supply) 97 Above Ground Level 98 For laying CPVC pipes of dia 32 mm 99 For laying CPVC pipes of dia 25 mm 100 Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements).The valves to be used on work shall be got approved by the Executive Engineer before use on work. 101 Gate valve 102 Fixing Gun Metal Gate Valve of 25 mm 103 Fixing Gun Metal Gate Valve of 40 mm 104 Wheel valve 105 Fixing Gun Metal Wheel Valve of dia 25 mm 106 Fixing Gun Metal Wheel Valve of dia 40 mm 107 Providing, fixing, Testing & Commissioning of PVC Ball valve with quarter turn including all necessary fittings & accessories complete. PIMTAS / AQVASTAR make 50 mm ( 2 ) 108 Providing, fixing, Testing & Commissioning of PVC Ball valve with quarter turn including all necessary fittings & accessories complete. PIMTAS / AQVASTAR make 40 mm ( 1.5 ) 109 Providing, fixing, Testing & Commissioning of PVC Ball valve with quarter turn including all necessary fittings & accessories complete. PIMTAS / AQVASTAR make 25 mm (1.00”) 110 Supplying and fixing in position 15mm dia brass CP Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works). 111 Supplying and fixing in position Health faucet of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works). 112 Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia B class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). 113 White Glazed Wash Hand Basin 114 With Pedestal 115 Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks). 116 Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works). 117 Supplying and fixing best approved best quality brass CP soap tray of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications.(The soap tray should be got approved by Executive Engineer before use on works). 118 Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level. 119 For laying PVC pipes of dia 110 mm 120 Supplying and fixing in position PVC cowls of 110 mm dia of best approved quality conforming to BIS, etc., complete complying with standard specifications.(The PVC cowl should be got approved by the Executive Engineer before use on works). 121 Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with P or S trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers.(The water closet should be got approved by the Executive Engineer before use on works). 122 Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm P or S trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications.(The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works). 123 White glazed European Water Closet with 10 litre capacity PVC flushing tank fixed on to wall 124 Supply and fixing in position of best Indian make white glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers.(The urinal should be got approved by the Executive Engineer before use on works.) 125 Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works).Nahani Trap of size 100 x 75mm with stainless steel gratings 126 Supplying and fixing in position 150 x 100mm P or S stoneware gully trap A grade with CI double gratings of size 150 x 150mm and 230 x 230mm at bottom and top respectively with necessary earth work excavation laid over a bed of brick jelly cement concrete 1:3:6 (One cement, Three sand and Six broken brick jelly) 150mm thick using 40mm size broken brick jelly including necessary brick work and plastering including dismantling masonry wherever necessary and re-doing the damaged portions to the original conditions using cement concrete 1:3:6 using 20mm stone jelly for fixing the gully trap and giving connections to stoneware sewer line etc., complete complying with standard specifications. [Earth work excavation, brick work, plastering shall be measured and paid separately]. The stoneware gully trap should be got approved by the Executive Engineer before use on works. 127 Supplying and fixing single phase 1 HP Monoblock pumpset as per I.S.I. specification on suitable pedestal with foundation bolt and nut including labour. Supply and fixing of starter and main switch suitable for 1 HP pumpset on suitable angle iron frame work with necessary labour including panel board.Supply and fixing 1 No. foot valve 1 for the 1 HP Mono block pumpset supply and run of 4 of 10 sq.mm. in PVC pipe with 14 SWG TC wire etc., complete. 128 Construction of Inspection chamber of size (clear 0.60x0.60x1.00) with necessary earth work excavation, sand filling, CC 1:5:10, brick work in CM 1:5, plastering in CM 1:5 12mm thick, Plastering in CM: 1:3 20mm thick, Precast slab 50mm thick, fabrication etc. complete as directed by the engineer-in-charge 129 Providing rain water recharging collection pit having a size of 900mm dia to a total height of 1200mm is 150mm above ground level and 1050mm below ground level with necessary augar bore of300mm dia to a depth of 3000mm from bottom level of collection pit and filled with 20mm HBG stone jelly inside of augar bore. The sides of collection pit provided with RCC Well ring of inner size of 900mm x 300mm x 50mm with 6mm reinforcement on both directionat 200 mm c/c using RCC 1:1/2:3 (one cement, one and half sand and three HBG jelly). The top of collection pit is finished with 50mm thick cover slab, The collection pit is filled with course river sand at top, 20mm HBG stone jelly at middle and 40mm HBG stone jelly at bottom of a depth of 300mm, 450mm and 450mm respectively. The rate is including the cost of RCC well ring and filling materials, RCC cover slab, drilling hole and labour charges for erecting the well ring etc.,and as directed by the departmental officers. 130 Supply, Fixing & commissioning of Pop up spray RD 1804 SAM PRS Series Spray bodies with high efficiency HE VAN Nozzle capable of covering radius of 0.9-4.6m at 1.0 - 2.1 Bars, pressure with Matched precipitation rate, tactile click and DU >0.7. Triple Blade Wiper Seal precisely balances flushing, flow- by and debris protection to optimize performance and durability at pop up and retraction. Precision-controlled flushing at pop-up and retraction clears debris, ensuring positive stem retraction in all soil types. Unique debris pockets hold grit in place, removing it from circulation and preventing long-term damage. Parts resistant to corrosion in treated recycled water containing chlorine. Pop spray body shall with stand upto 6.9 bar. Built-in Seal-A-Matic™ (SAM) check valve. Traps water in lateral pipes in elevation changes of up to 14 feet (4.2 m). PRS Maintains constant outlet pressure at 30 psi or 45 psi at varying inlet pressures. etc., RD1804- SAM PRS-HE VAN incl installation charges 131 Supply of large capacity Disc filter 25 M³ / Hr including installation charges. (brands like Rain Bird or equivalent) 132 Flexible polyethelene irrigation pipe 16 mm dia / 2.5 / 1.1 - 1.4 mm CL - II. Netafim including installation charges. 133 Supply of endcap, nipple, start nipple, rubber grommet 16 mm dia. Netafim including installation charges. 134 Supply of Pressure compensated dripper with 2 / 4 / 8 LPH outlet flow. Rain Bird / Netafim make including installation charges 135 Supply of Micro sprinkler of half & full circle with 55 LPH output flow with necessary micro tube & stake. Rain Bird / JISL make including installation charges. 136 BOREWELL 137 Drilling of 12 dia vertical borewell so as to have a finished size of 6 dia borewell in boulder area to any required depth as decided by the TWAD Board Officers including Transportation from one place to anothr place with in Tamilnadu State by direct or reverse rotary mud circulation method using Contractors rig tools, fuel, labourers etc 138 Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 140 mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs, fuel, labour and drilling bentonite and water required for drilling at site ( Site will be shown by the TWAD Board Officers) including construction of mud pit 139 Drilling of 140/150 mm pilot bore - Upto 60 m Depth ending below ground level 140 Drilling of 140/150 mm pilot bore - From 60 m upto 90 m Depth ending from ground level 141 Drilling of 140/150 mm pilot bore - From 90 m upto 120 m Depth ending from ground level 142 Reaming 300 mm dia pilot bore to 400mm/ 450mm dia bore as directed by the TWAD Board Officer. 143 Upto 60 m depth ending below ground level 144 Reaming 140/150 mm dia pilot bore to 300mm dia bore as directed by the TWAD Board Officer. 145 Upto 60 m depth ending below ground level 146 From 60 m depth and upto 90 mt depth ending below ground level 147 From 90 m upto 120 mt depth ending below ground level 148 Supply and laying following dia PVC casing pipe with excise duty as per IS 12818 / 2010 149 200mm dia CS 150 150mm dia RS 151 Labour charges for inserting PVC casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC couplers with cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the Executive Engineer of Departmental officers. 152 200mm dia CS 153 150mm dia RS 154 Supplying and filling with river pebbles in annular space between bore and PVC pipe up to hard rock 155 Charges for developing the borewell with air compressor of 300 CFM capacity (Minimum 8 Hours) including ransportation labour and fuel charges for compressor as directed by TWAD Board Officers and conducting yieldtest by V notch method. 156 Supply ,erection and testing & commisioning of 3HP submersible pumpset in the to suit 200mm borewell of capacity of 4800 LPH @ 265Ft, max. total head of 280 Ft pumps fitted with bronze impellers and having delivery size of 40mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge and other required supporting items like SS hose nipple, nylon rope, clamps, bolt and nuts,GI nipple, 50mm dia HDPE hose of required length etc completed and as directed by the officer incharge. 157 Supplying and fixing single phase 5 HP Monoblock pumpset as per I.S.I. specification on suitable pedestal with foundation bolt and nut including labour. Supply and fixing of starter and main switch suitable for 5 HP pumpset on suitable angle iron frame work with necessary labour including panel board.Supply and fixing 1 No. foot valve 2 for the 5 HP Mono block pumpset supply and run of 4 of 10 sq.mm. in PVC pipe with 14 SWG TC wire etc., complete. 158 LANDSCAPING WORK 159 Supply & stacking of red earth at site to the departmental guage for pre-measurements which is of light textured, crystalline, porous and friable and not of generally acidic or neutral but not of alkaline and should be fertile, including seignior age charges, cost of transportation, loading, unloading, stacking and inclusive of all taxes etc., complete. 160 Supply of well decomposed Farm yard Manure in a powdery form, devoid of soil sand, stones, plastics and other materials, highly nutrient and which supports plant growth. 161 Supply and stacking of pit sand / earth filling sand at site to the departmental gauge for pre measurements obtained from sand deposits and should clean without solid particles 162 Mixing charges of Red soil, sand and manure uniformly (1:1:1) for Preparation of soil mixture (excluding material cost) 163 Spreading of red soil, gravel or sand including watering and rolling which hand roller for every 75 mm thickness - including hire charges of roller 164 Preparation of Mounds of various size and shape by availlable excavated/ Supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer - in - charge 165 Planting of Lilly - Hymenocallis Lilly (Spider liiy) shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge 166 Planting of Plumaria Dwarf ornamental foliage Specimen plant variety of height 105- 120 cm in polythene bag of size 16x16 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 167 Planting of Duranta new gold Plant ornamental foliage shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 168 Supplying and Planting of Peltophorum tree sapling of height 240 – 300 cm in polythene bag of size 20x21 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 169 Planting of Bougainvillea Specimen plant variety of height 105-120 cm in polythene bag of size 16x16 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 170 Supplying and Planting of Picharidia palms variety of height 180-210 cm in polythene bag of size 16x16 inch including supporting stack of 5cm dia casurina pole of 10 height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 171 Supplying and Planting of Roystonea regia (Royal palms) palm variety of height 180-210 cm in polythene bag of size 16x16 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 172 Supplying and Planting of Pungam tree sapling of height 240 –300 cm in polythene bag of size 20x21 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge 173 Supplying and Planting of Bauhinia purpurea tree sapling of height 240 – 300 cm in polythene bag of size 20x21 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed bythe site in-charge. 174 Supplying and Planting of Spathodea campanulata tree sapling of height 240 – 300 cm in polythene bag of size 20x21 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in charge. 175 Supplying and Planting of Cane Bamboo tree sapling of height 300 - 360 cm in polythene bag of size 15x16 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge 176 Planting of G2 grass including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 177 CHILDREN PARK AND GYM EQUIPMENTS 178 Supply and fixing of Straight Slide - 7ftLength 450cm ( 15ft ) x Width 75cm ( 2.5ft ) x Height 210cm ( 7ft ) Slide Material : Polyethylene Slide. Slide Length : 21cm ( 7ft ), Slide platform height : 120cm ( 4ft ), Base platform size : 2ft x 2ft, Platform base : Aluminium Checkered Sheet. Center Post : 114mm OD Galvanized post, Side Post : 50mm (2) OD Galvanized post, Powder coating : Electrostatic pp coating on metal parts. Area Required : Length 600cm ( 20ft ) x Width 150cm ( 5ft ) Playing age group : 3 - 10 yrs. Children capacity : 1Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. All fastners closed with polyethylene caps for children protection. 179 Supply and fixing of Park Spiral Slide Junior (FRP)Size: L10.5 x W6 x H7Safe Area Size: L20.5 x W5 x H11.5Material specifications:Ladder : Galvanished ‘B’ Class pipe Sliding chute 9ft BED LEG :Galvanished ‘C’ Class pipeFRP thickness 4mm. (Reinforced Polymers in 5 Layers) 450 CSM Matt, 600 Roving Mat, Isotolic gel coat with PU pigment.ISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball BearingHigh quality Glossy paint with primer 180 Supply and fixing of Cross Swing - 3 Seater Length 390cm ( 13ft ) x Width 120cm ( 4ft ) x Height 225cm ( 7.5ft ) Swing Seat material : LLDPE seats fitted with Stainless steel hooks. Swing Chain : PU coated coated galvanized chain Imported. Swinging Hook : Heavy duty Aluminium pressed with sealed bearing. Swing post : 114mm ( 4.5 ) OD G.I post of wall thickness 2mm, Centre post : 114mm ( 4.5 )OD G.I post of wall thickness 2mm, Playing age group : 3 - 12yrs. Children capacity : 3Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. Swing chain made of PU coated chain , Seat made of LLDPE ( Polyethylene), Swing hooks made of Aluminium with sealed bearings.4. All fastners closed with polyethylene caps for children protection. 181 Supply and fixing of Seesaw - SingleLength 210cm ( 7ft ) x Width 90cm ( 3ft ) x Height 60cm ( 2ft )Seesaw seat material : LLDPE - Polyethylene. Qty : 2Nos.Seesaw center & side post : 89mm ( 3.5 ) OD Galvanized post,Seesaw handle post : 32mm ( 1.2 ) OD Galvanized post,Seesaw post top cap : Heavy duty Aluminium,Powder coating : Electrostatic pp coating on metal parts.Area Required : Length 300cm ( 10ft ) x Width 210cm ( 7ft )Playing age group : 3 - 10yrs.Children capacity : 2Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. All fastners closed with polyethylene caps for children protection. 182 Supply and fixing of Park Seesaw 4 Seater (FRP Seat)Size: L8.75 x W5 x H3 Safe Area Size: L11.75 x W8 x H6 Material specifications:Frame : 1 ½” Galvanished ‘B’ Class pipeSee saw Rail :2” Galvanished ‘C’ Class pipeSeat : FRP Seat with 450 CSM Mat 3 Layers bonding. Isotolic gel coat with UV pigment.Painting with PU coating seatISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball Bearing 183 Supply and fixing of Merry go round - 6 Seater Diameter 180cm ( 6ft ) x Height 75cm ( 2.5ft )Galvanized 50mm dia pipe used for outer ring.Heavy duty Tapper roller bearing setting on the base for smooth rotation.Powder coating : Electrostatic pp coating on metal parts.Area Required : Length 240cm ( 8ft ) x Width 240cm ( 8ft )Galvanized semi circle seats - 2Nos with side saftey handles.Playing age group : 3 - 12yrs.Children capacity : 6Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. All fastners closed with polyethylene caps for children protection. 184 Supply and fixing of Spring Rider - Dinasour Polyethylene Dinasour design attached with 22mm heavy duty coil springs mounted on 10mm Base plate. Metal part powder coated. Safe area - 6ft x 6ft. Playing age group : 3 - 10yrs. Children capacity : 2 Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. All fastners closed with polyethylene caps for children protection. 185 Supply and fixing of Park Loop RungSize: L10 x W2 x H7.5Safe Area Size: L13 x W5 x H10Material specifications:Post-Galvanished ‘B’ Class pipeTop rail-Galvanished ‘C’ Class pipeSprings –Galvanished ‘C’ Class pipe.Painting with PU coating ISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball BearingHigh quality FRP Materials with U~V resistance pigments and ISO Resign and 600 GSM Mat 186 Supply and fixing of Park Flat RotorSize: L5 x W5 x H3.25’ Safe Area Size: L8 x W8 x H6.25Material specifications:Pipes - 1’’GI pipe, 3/4”GI pipe, 3”GI pipe, 2.5mm thick, B class paint: PU coatingISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball BearingHigh quality FRP Materials with U~V resistance pigments and ISO Resign and 600 GSM Mat 187 Supply and fixing of Park Arch Swing 2 Seater (FRP)Size: L10 x W3 x H6.75Safe Area Size: L13 x W6 x H10Material specifications:ARC-Frame : 2.5mm thickness Galvanished ‘B’ Class pipe Top Rail : 2” Galvanished ‘C’ Class pipe with 4.5mm thickSeats : RubberChain : 8mm Stainless Steel Chain (Grade-304)Painting with PU coating ISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball BearingHigh quality FRP Materials with U~V resistance pigments and ISO Resign and 600 GSM Mat 188 Supply and fixing of Air Walker Single personSize: L3.75 x W1.25 x H5 Safe Area Size: L6.75 x W4.25 x H8Material specifications:Main Post made of 4 Inch Pipe and other main pipes 1-1/2 inch Pipes. 3 mm thickness pipes (1680 x 515 x 1780 mm) 4 mm pipe Double coat Powder coating, Heavy duty Branded sealed Ball bearing, for long lasting life. Steel Foot rest / Foot Paddle for long lasting life. 189 Supply and fixing of Chest Press - Single PersonSize: L7.5 x W2.5 x H6Safe Area Size: L10.5 x W5.5 x H9Material specifications:Main Post made of 4 Inch Pipe and other main pipes 1-1/2 inch Pipes. 3 mm thickness pipes. Double coated Powder coating, Heavy duty Branded sealed Ball bearing, Steel & foot rest / Foot Paddle for long lasting life 190 Supply and fixing of Leg Press - Dual PersonDimension : L 120cm ( 4ft ) x W 45cm ( 1.5ft ) x H 130cm ( 4.3ft ) Material : Galvanized Steel. Fastners : Stainless steel 304 grade with Polycaped. Post top Cap : High density Aluminium. Handle grips : HD Rubber coated. Twister Base : Polyethylene. Bearing setting for smooth rotation. Main Post Size : 115mm / 4.5 OD G.I post of wall thickness 3mm. Handle Post Size : 32mm / 1.25 OD G.I post of wall thickness 3mm. Powder coating : 80 micron Akzo nobel electrostatic coated. Area Required : Length 180cm ( 6ft ) x Width 180cm ( 6ft )All Metal posts are made of Galvanized pipes with elecrostatic powder coated. 191 Supply and fixing of Push Up / Pull BarSize: L3.5 x W3.5 x H6.5Safe Area Size: L6.5 x W6.5 x H9.5Material specifications:Main Post made of 4 Inch Pipe and other main pipes 1-1/2 inch Pipes. 3 mm thickness pipes Double coat Powder coating, Heavy duty Branded sealed Ball bearing, for long lasting life. Steel Foot rest / Foot Paddle for long lasting life. 192 Supply and fixing of Shoulder Wheel - Single PersonSize: L2 x W2.5 x H6.25Safe Area Size: 4 x 5.5 x 9.25Material specifications:4mm pipe thick Main Post made of 4 Inch Pipe and other main pipes 1-1/2 inch Pipes. 3 mm thickness pipes Double coat Powder coating, Heavy duty Branded sealed Ball bearing, for long lasting life. 193 Supply and fixing of Excer CycleProduct Dimension : L 85cm ( 2.8ft ) x W 83cm ( 2.7ft ) x H 182cm ( 6.1ft ) Material : Galvanized Steel. Fastners : Stainless steel 304 grade with Polycaped. Post top Cap : High density Aluminium. Rotating Knobs : Polyethylene. Bearing setting for smooth rotation. Main Post Size : 115mm / 4.5 OD G.I post of wall thickness 3mm. Handle Post Size : 32mm / 1.25 OD G.I post of wall thickness 3mm. Powder coating : 80 micron Akzo nobel electrostatic coated. Area Required : Length 180cm ( 6ft ) x Width 180cm ( 6ft )All Metal posts are made of Galvanized pipes with elecrostatic powder coated. 194 Supply and fixing of Lat Pull Down - Single personDimension : L 100cm ( 3.3ft ) x W 75cm ( 2.5ft ) x H 180cm ( 6ft ) Material : Galvanized Steel. Fastners : Stainless steel 304 grade with Polycaped. Post top Cap : High density Aluminium. Handle grips : HD Rubber coated. Seat & Back rest : Polyethylene. Bearing setting for smooth rotation. Main Post Size : 115mm / 4.5 OD G.I post of wall thickness 3mm. Handle Post Size : 50mm / 2 OD G.I post of wall thickness 3mm. Powder coating : 80 micron Akzo nobel electrostatic coated. Area Required : Length 180cm ( 6ft ) x Width 180cm ( 6ft )All Metal posts are made of Galvanized pipes with elecrostatic powder coated. 195 Supply and fixing of Sit Up BoardDimension : L 142cm ( 4.7ft ) x W 112cm ( 3.7ft ) x H 63cm ( 2.1ft ) Material : Galvanized Steel. Fastners : Stainless steel 304 grade with Polycaped. Post top Cap : High density Aluminium. Base material : 25mm OD Galvanized Oval pipes. Post Size : 115mm / 4.5 OD G.I post of wall thickness 3mm. Post Size : 45mm / 1.5 OD G.I post of wall thickness 3mm. Powder coating : 80 micron Akzo nobel electrostatic coated. Area Required : Length 240cm ( 8ft ) x Width 240cm ( 8ft )All Metal posts are made of Galvanized pipes with elecrostatic powder coated. 196 KIOSK 197 ACP KioskSupply of Kiosk: MS Tube Frame Covered with ACP Panel Size: 3m x 2m Bottom: Bison Board 1” Thick Front: Large Door with Double Piston Left Side: Access Window Right Side: Main Door With Lock Top: ACP Sheet (Puff Panel) Table: 7.5Ft x 1.5’ Width 1no Accessories: Fan 1No, Tube light 2Nos, Switch Box 1No, MCP 1No, Exhaust Fan 1No, Wash Basin 1No, Vinyl Flooring, LED Name Board with Logo, Menu Card 198 ELECTRICAL WORKS 199 LT CT TNEB METER BOX: Supply, Installation, testing and commissioning of compartmentalised LT 3Phase, TNEB Metering box of outdoor weather proof type with MS mounting stand, Test Terminal Blocks, Internal control wiring etc., as per local TNEB standards. The box suitable for 3phase 100A service connection made up of with hylem sheet of size 2feet x 1-1/2feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of3Nos.100A fuse units (500V),1No.neutral link,copper earth flat of size1x1/4 with interconnection of EB meter tofuse units by 16 Sq.mm PVC insulated copper wire with suitable necessary connection with earth connection complete. 200 Supply and fixing of 125A TPN Isolator in sheet steel enclosure with double breakon suitable angle iron frame work with MS cable entry boxes with earth connection only. 201 MAIN LT PANEL: Supply, Installation, testing and commissioning of 3Phase, 415Volts, Main LT Panel board of Indoor, Cubicle floor mounting type made out of 2mm thick CRCA Sheet with powder coated finishing, MS base frame, double internal earthing arrangements, 125Amps, rating TPN Copper busbars with interconnection busbar, etc., comprising of the followings:EB Incomer :1 No. 125Amps, 25kA, 4Pole, Thermal magnetic MCCB with Ext.RHOMMetering : 1 Set of RYB LED Indication lamps1 No. of Multifunction Meter with RS 4851 Set of Current Tranformers (125/5A, Cl-1), 1 No. 125/5A CT for APFCR1 Set of Control MCBs Outgoings: 7 Nos. 63Amps, TP+N MCCB 2 Nos. 32Amps, TP+N MCCB3 Nos. 25Amps, DP MCB[Size:2400mm (L) x 350mm (D) x 2000mm(H)] 202 APFCR PANEL - 25KVAR: Supply, Installation, testing and commissioning of 3Phase, 415Volts, 25KVAR rating APFCR (Capacitor) Panel board of Indoor, Cubicle floor / wall mounting type made out of 2mm thick CRCA Sheet with powder coated finishing, MS base /wall frame, double internal earthing arrangements, 63Amps, rating TPN Copper busbars with interconnection busbar, etc., (1 x 10KVAR + 2 x 5KVAR + 1 x 3KVAR + 1 x 2KVAR) 203 12WAY Outdoor Lighting DB - 1 to 5: Supply, Installation, testing and commissioning of Outdoor weather proof type 3Phase Outdoor Lighting DB comprising of 1 No. 63Amps, TP+N, MCCB with Extended RHOM as incomer with RYB LED Phase indication lamps, 3Phase 63Amps, 4Pole Timer internal control wiring, etc., Outgoings: 11 Nos. 16A-32Amps, 4P MCBs &3 Nos. 20Amps, DP MCBs including Copper busbar connections, interconnection cables, cable entry provisions, floor mounting frame (600mm to 900mm), etc., 204 SLDB-1 to 4 and ELV UPS DB: Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1no. 32A DP MCBswitch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wallwith earth connection only.Higher End 205 Pump room DB - 1 & 2: Supply and fixing of 8 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB switch as incoming and 5 nos. 32A 3P MCB, 9 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End 206 SupplyandLayingof31/2 Corex120 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 207 SupplyandLayingof31/2 Corex70 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good 208 SupplyandLayingof31/2 Corex50 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 209 SupplyandLayingof31/2 Corex95 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 210 SupplyandLayingof31/2 Corex25 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 211 Supply and Clamping of 2 core x 10 Sq.mm PVC armoured LTUGaluminium cable on post or on wall MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable. 212 Supply and fixing of brass cable gland for 2 x 10 sq.mm. PVC armoured LTUG cable with earth connection 213 Supply and fixing of brass cable gland for 3-1/2 x 25 sq.mm. PVC armoured LTUG cable with earth connection 214 Supply and providing cable end termination of 3-1/2 x 25 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 215 Supply and fixing of brass cable gland for 3-1/2 x 50 sq.mm. PVC armoured LTUG cable with earth connection 216 Supply and providing cable end termination of 3-1/2 x 50 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 217 Supply and fixing of brass cable gland for 3-1/2 x 70 sq.mm. PVC armoured LTUG cable with earth connection 218 Supply and providing cable end termination of 3-1/2 x 70 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 219 Supply and fixing of brass cable gland for 3-1/2 x 95 sq.mm. PVC armoured LTUG cable with earth connection 220 Supply and providing cable end termination of 3-1/2 x 95 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 221 Supply and fixing of brass cable gland for 3-1/2 x 120 sq.mm. PVC armoured LTUG cable with earth connection 222 Supply and providing cable end termination of 3-1/2 x 120 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 223 Supply and erection of GIHotDip/PowderCoated16SWGPerforated type CableTraywith 300mm width and 50mm height with all the fixing accessories 224 Supply and Run of 2 of 2.5 sq.mm.PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable gauge MS conduit pipe Concealed inwall and ceiling with continuous earth wire connection of 2.5 sq mm copperwire and making good of the concealed portion 225 Supply and Run of 2 of 6 sq.mm.PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable gauge MS conduit pipe concealed inwall and ceiling with continuous earth wire connection of 6 sq mm copperwire with painting of suitable colour. 226 Supply andrunof2 of4 sq.mm. PVC insulatedSC unsheathedFRLS copperconductorof1100V gradeinsuitable heavy gauge MS conduit pipe concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm copper wire and making good of the concealed portion wiith suitable colour 227 Supply and fixing of 1 no.6A two module 5 pin socket , 1 no.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 228 Supply and fixing of 2nos.6A two module 5 pin socket , 2 nos.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 229 Supply and fixing of 1 no.6/16A two modulesocket , 1 no.16A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 230 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End (Primary) 231 Supply and fixing of 18W LEDRound type Recessedfitting with LED (Higher end) on false Ceiling from ceilingwith PVC unsheathed copper leads from terminals to the fitting. 232 Supply and erection of 20Watts, 4 Feet LED Fitting with LED (Higher end) end cap, PVC unsheathed copper leads from terminals to the fitting and fixing accessories 233 Supply and fixing of 60Watts All-in-One (AIO) Model Solar Street Light with 6000mm Height pole with base plate and all the fixing accessoriesThe cost is inclusive of civil foundation works including anchor fasteners,etc., as per site requirements 234 Supply and fixing of 3W RGB Light fitting (IP67) Inground fixture with PVC unsheathed copper leads from terminals to the fitting and to complete necessary accessories and etc to complete the work. KLITE:4092 - symmetrical Inground 235 Supply and fixing of spike light 6W fitting on floor with PVC unsheathed copper leads from terminals to the fitting and to complete necessary accessories and etc to complete the work. KL-Trioscope - 7052 236 Supply of One No of 9.5 mtr. Street Lamp Post With 2.7 mtr Arch Double Bracket, 1 No. of 4 Core SMC Fuse Box With Hot Dip Zinc Galvanising 237 Cost of Erection & Materials Required For 9.5 mtr Street Lamp Pole With Brackets Conventional Foundation(Material Ratio - 1:1.5:3) 238 Supply and fixing of 300mm (12) sweep(Heavy Duty) AC exhaust fan complete with necessary wall opening and making good of the wall . 239 Supply and fixing of MS / Fibre Louvers Shutters arrangements for 300mm ACExhaust Fan (M-1346) 240 Supply and fixing of 1200mm (48) sweep AC ceiling fan 5 star ratedcomplete ( Higher end)with 2 module 100W fan step regulator (Higher end)with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18) 241 Supply and fixing of Maintenance Free earthing with Copper rod of 17.2 mm dia and 3m length including all the civil works 242 Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection 243 Supply and Run of1 of No.8 SWG copper wire for earth connection 244 Supply and Run of1 of No.8 SWG copper wire in suitable PVC rigid pipeon wall / floor / ground for earth connection 245 Supply of 2mx1mRubberMatsuitablefor11KVinstallation confirming to IS 246 Supply of First Aid Box complete with all First Aid Medicines 247 Supply and fixing of Shock Treatment chart with Glass frame(in English & Local Language) 248 Supply and fixing ofMetallic Danger Board as required by the Electrical Authorities (415Volts & 230Volts) 249 Supply and Installation for 2KVA, UPS (Single Phase Input & Single Phase Output) Capacity with 2Hourse Battery back up, battery stand and interconenction cables. 250 Supply and fixing of 40Amps, 30mA DP RCCB in a suitable sheet steel enclosure and necessary fixing accessories (Higher end) 251 CCTV SYSTEM 252 Supply, Installation, Testing and commissioning of 32 channel 8 SATA NVR, with 10TB Hard Disk Drive 2 nos, New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected,Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output  HDMI1 / VGA1 outputs provided  HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface for HDD connection, Support upto 10TB capacity for each HDD, Smart search for efficient playback. and smart playback to improve the playback efficiency, Supports VCA search for fire/ship/temperature/temperature difference detection triggered video files, POS information overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access  Hik-Connect for easy network management, 2 Gigabit Ethernet network interfaces. 253 Supply of 4MP, Internet Protocol fixed BULLET CAMERA (OUTDOOR) with following specification:a) 1/2.5 Progressive Scan CMOS, b) 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behavior analyses ( Line crossing detection, intrusion detection)c) Face Detection d) 120dB WDR, e) BLC/3D DNR/ROI, IP67 compliedff) On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,g) Shutter Speed 1/3 s to 1/100,000 s, h) 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, i) rotate: 0° to 360°, 2.8 mm, j) horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, k) Lens Mount M12 & IR Range I5: up to 50 m, l) Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, m) Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9Wn) Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse. with Camera Stand. 254 Supply of 8MP, Internet Protocol fixed BULLET CAMERA with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behavior analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse with suitable Stand. 255 Supply, Installation, Testing and Commissioning of 55 smart LED TV with following specifications a) Resolution: Ultra HD (4K) 3840 x 2160b) IPS panel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -2nos n) Built in LAN o) Magic remote 256 Supply and Clamping of CAT 6 unarmoured cable in suitable PVCPipe 1 thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem)i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal)IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-TIEEE 802.5 16 MB; ISDN; TPDDI; ATMii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant.Fire Rating: PVC : IEC 60332-1.iii. Conductor - Bare Copper Wireiv. Insulation - Polyethylene v. Twisting - 2 Cores to the pair vi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm. 257 Supply and laying of armoured, Multimode, Thermoplastic Tape Inner Sheathed, PVC type sheathed 6 core Optical Fibre Cable withunique fiber excess length control method provides the cable with excellent mechanical and environmental properties and Cable - 2 Embedded FRP provides tensile strength & Anti-buckling properties. It is processed with Filling jelly - Thixotropic jelly to prevent Water ingress in loose tube. 258 Supply and Termination of Optical Fibre Cable Single Point ( Point to Point ) Splicing and arrangement charges. 259 Supply and fixing of POE 8port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. 260 Supply and Fixing of Rack with Accessories -Higher end6U Rack with fan extra for the above rack. (speaker/data/cctv) 261 Supply and fixing of POE 24 port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. 262 Supply, Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point ( Point to Point ) Crimping, Testing and arrangement charges. 263 Supply and fixing of outdoor 4X6PVC box with 102mmX77mmX102mm with all fixing accessories. 264 Supply and Erection of 6mtrLengthpole with base plate of size 300x300x12mm as per IS-875 with following specification. Pole Outter dia -76.10mm x 3.65mm Thick x 6 meter with foundation Charges.The Pole Should be hot dip Galvanized confirming to BESN ISO-1461 with thickness of 65 Micron 265 PA SYSTEM 266 Supply, Installation,Testing & commisioning of 30 watts 2 way high efficiency, high fidelity, long throw IP65 weather proof P.A Music Horn WALL / COLUMN speaker. It combines the high efficiency of horn with wide frequency response.Music horn is weather protected and UV protected ABS plastic housing combines with the feature of easy poertap selection on a terminal strip with a two core cable.It has impedence of 250/500/1k/2k ohm with frequency response of 120-16000 hertz. 267 Supply, Installation,Testing & commisioning of 480 watts P.A Booster Amplifier with the output power of 1350 watts maximum, 500watt rms at 10% Thyristor harmonic distortion(THD), 850watt RMS at 5% THD, 800 wattsRMS at 2% THD and the power supply AC voltage ranging from 220-240 volt, 50/60 hertz. with the DC input of 48 volt and 1000watts has tone controls of Bass=+- 10 db at 100 hz weighing 42kg with the speaker output of2Q,4Q.70volt&100volt has power consumption of 1600VA AC &12A DC and 100db output regulation at 1khz no load to full load ratio. The signal to noise ratio is 60db with the imnput channels of 0.8mv/4.7kq,3*Aux 100mv/50kq.The frequency response of 50-15000hz+-3db. 268 Supply, Erection,testing & Commisioning of custom built table top 4 zone micro processor based 1 way announcement console cinsisting of teleline preamplifier , 1 x priority module , 12 zone selector module , all call switch module , tone oscilator modulefor fire evacation, press to talk switch module,goose neck microphone ,24v dc rectifier module, power supply uit , all call relay module etc as required.(Delegate unit) 269 Supply and Fixing of Rack with Accessories -Higher end6U Rack with fan extra for the above rack. (speaker/data/cctv) 270 Supply, run, testing and commissioning of2Core x 1.5sq sqmm PVC insulated Armoured Speaker Cable in suitable 25mm dia Pvc Rigid pipe concealed on wall and ceiling with continuous earth wire connection with painting of suitable colour.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
24.
Housing Urban and Rular Development #10200585 Price Bid
Tender For Construction Of New Muthalvar Padaippagam At Bhakthavachalam Park, Chennai; 1 Civil Works 2 Dismantling removing the existing Reinforced Cement Concrete work etc., by using required mechinaries includingdisposal of unserviceable material, labour charges, as per direction of Engineer in charge. 3 Dismantling removing the existing Brick work etc., by using required mechinaries includingdisposal of unserviceable material, labour charges, as per direction of Engineer in charge. 4 Removing the existing ventilators,doors and windows including removal of frames ,hinges and fastenings arefully and stacking the same at site etc., complete. 5 Dismantling Floor finish and daddoing walls in cement mortar with mosaic tiles/glazed tiles/cuddapah slabs. 6 Carting away the surplus earth and debris to a lead of 5kgm.including Loading, unloading and dumping in the Corporation Land as directed during the execution. 7 Dismantling removing the existing closet, fitting, pipes, etc as per site., by using required mechinaries includingdisposal of unserviceable material, labour charges, as per direction of Engineer in charge. 8 Civil Works 9 Providing and constructing cast in situ hydraulic bored piles of specified diameter in M30 grade concrete using blended cement - slag cement with minimum cement content of 400kg/m³in accordance with the structural engineers drawings and directions, but exculding reinforcement including cost of mobalization of all necessary plants, equipments like piling rigs, temporary casing of appropriate length forsetting out cardinal points and the removal of the same, boring in overburden, using bentonite mud circulation technique or any other method dulythrough all strata upto the foundation level of piles etc., complete all as approved by the departmental engineer. Further include dewatering, placing concrete by tremie pipe method, disposal of bored material outside the site. Including Chipping carefully cut off portion of piles as required without any damage to the piles and dressing the top and removing all the debris away from the site with out any extra cost as directed including the cost of all tools, plants, conveyance, all labour, lead and lift required etc .,Conducting standard penetration test to identify the refusal strata for atleast 1 pile in group and atleast 25% of piles, comparing with refusal strata as indentified in soil report and providing socketting into refusal strata by 1.00mt or into hard rock by 100% dia of the pile. (Length of pile for payment shall be measured up to bottom of pile cap). 10 Boring or chiselling through any obstacles, boulders, weathered rock, etc. Upto founding level of piles for seating resting or socketting of files. The rate quoted shall include demobilising the site with all plants, equipment, piling rigs, necessary personnel brought for piling work, including removal and transportation of debrise away as directed, cleaning and reinstating site to original condition as acceptable by the Architect on completion of piling work. 11 450 mm Dia 12 Carrying out initial working pile load test on specified dia piles as specified in IS:291 1 (Part 4). Includes all plant, equipment, machinery. Instruments, measuring devices, platforms and kentledge pile caps etc., dismantling and carting away entire setup, excavation and dewatering etc., all complete 13 Earth work excavation for all foundations in all type of soils and sub soils to the required depth for Footings, plinth / grade beams, etc,. by mechinaries including manual excavation for the following type of soil / rock as per detailed specification. As per SS 20B as hard rock requiring blasting inclusive of shoring strutting and baling out water wherever necessary and including refilling 0 to 2.0m depth consolidation depositing the surplus earth in places shown clearing and leveling the site with an initial lead of 10 metre and lifts as specified hereunder etc., complete in all respects complying with relevant standard specification and as directed by the departmental officers. 14 Supplying and filling of Gravel / Good Earth by lorry in Foundation basement filling and site filling with approved materials excavation from approved quarries and compacted to meet requirement of table 300-1, 300-2 of MORTH, in layers not exceeding 300 mm loose thickness, spreading, breaking clods, removal of roots and other organic materials to the required line, grade and cross-section including watering, spreading by Dozer, grading by motor grader and consolidation by vibratory road roller with desired field density not less than 95% of maximum dry density ,including all lead,lift, loading, unloading, all labour, hire charges of all machineries, Transportation, etc., complete in accordance with MORTH technical specification clause No. 305 and with all other incidental charges and as per the direction of the Engineer-In-Charge. 15 Providing Pre construction Anti termite treatment for the building including all chemicals as per standard specifications. Labour charges for preparing the areas for treatment spraying chemicals and other incidential charges etc., complete. The rate shall be inclusive ofgiving anti-termite treatment to the building for the following four stages including breaking the termite mounds making holes with crow bars at an intervel of 12to a depth of 8 in the periphery of building and pouring chemicals etc., complete as per ISI 6313-1981 and. The antitermite chemicals used should have 0.5% concentration with 3L solution for the entire operation etc. as directed by the Engineer incharge and including cost of chemicals labour transportion etc., 16 Stage:1 Spraying Anti-termite treatement chemicals solution for the foundation before laying the foundation concrete bottom and sides of the foundation. 17 Stage:2 Spraying anti-termite chemicals solution to the grade beams level spraying has to be done for the grade beams brick masonry in the superstructure in contact with back fill earth. 18 Stage:3 Spraying anti-termite chemicals solution on sand for the flooring before laying the flooring concrete. The treatment has to be carried out on the sand filling the basement after leveling operation is over. 19 Stage:4 Spraying anti-termite chemicals solution around the building outside of the building by making crow bar holes at an intervel of 12 to a depth of 8 around the building before laying the plinth projection.This holes has to be be closed after the treatment. 20 Supplying and Filling withM-sand in floor and others sub structures for 150mm thick and well watered, rammed and consolidated by power compacter. The rate includes the cost of river sand, compacting with mechanical compactors, labour charges for leveling, loading & Unloading and Transportation charges etc., complete and as per the standard specification. 21 Construction of Wet Mix Macadam 150mm compacted thickness in two layers by providing , laying , Paving , and compactingofaggregate gradation satisfying to Table 400-13 of MORTH and satisfying the physical paraeteres as per MORTH Table 400-12, mixing in a Wet Mix Plant of 200 tonne capacity at OMC , carriage of mied material to work site and laid in sensorpavers to the required line and grade as per the drawing and compacted with vibratory roller of 8-10 tonne to achieve the desired density of 98% of Maximum dry density and as per the direction of the Engineer-In-Charge of work. 22 Providing and laying plain cement concrete 1 : 4 : 8 ratio of(1 cement , 4 sand and8 graded stone aggregate 40mm nominal size) in foundation and basement for 100mm thick including dewatering wherever necessary and consolidation etc. The rate includes the cost of materials, labour charges, lifting charges, loading & Unloading and Transportation etc., complete and as per the standard specification. 23 Supplying and erecting centering for sides and soffits including supports and strutting up to 3.30 m height with all cross bracing for plane surfaces as detailed below, using mild steel sheets of 90 X 60 cm 10 gauge stiffened with MS angle of 25 X 25 X 3mm for boarding, laid over adjustable span & jacks and supported by 50mm dia pipes for general pipes scaffolding systems @ a spacing of 1.20m c/c and vertical connected at a height of 2.0m c/c including C & U clamps and base receiver cup at bottom for connecting pipes etc and removable systems etc., the rate including cost of all materials, labour charges, wastages, placing, transportation, lead & lifts, tools & plants, fuels, fixing in position at all levels, heights, masking tape in sheet joints, consumables, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 24 For column footing plinth beam , pile cap staircase steps, piers raft beam raft slab etc., 25 For Plain surfaces such as RCC slab, Beam, Bed Block, waist slab, landing slab, lintel etc., 26 For square or rectangular column, boxing, sunshade etc., 27 Providing and Laying M 30 Standardised concrete Mix for all reinforced cement concrete with minimum cement content conform to IS 456-2000 using ordinary Portland cement of grade 53 from approved manufacturer, manufactured sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement. works for Footings, Grade beam, retainning wall drain wall & raft , Plinth beams, Column, Grade slab, Roof slab & beam, Column drops, Pergola, Staircase waist and landing slab lintel, Sunshades, parapet Cum drops, Steps, canopy, window boxing slab, Loft, fins facia Planter box, machine foundation, elevation features and other similar structures etc..excluding necessary centering, shuttering and reinforcement which shall be measured and paid separately under relevant items. in-charge The rate including cost of all designing the mix, batching plant, mechanical mixing, transporting and placing at all levels, leads, lifts, tools & plants, fuels, all materials, labour charges, wastages , laying, pumping the concrete to all levels, providing sleeves / openings in RCC slabs, compaction by vibrator, gunny bags for curing etc. as complete with all respects complying with relevant standard specification, as directed by theEngineer-in-charge 28 Basement 29 GF 30 FF 31 Terrace 32 Supplying, fabricating and fixing in position of steelFe 550 grade Reinforcement for all RCC work with Thermo Mechanically Treated Bars (TMT) conforming to IS 1786 of latest version according to drawings and binding the reinforcement with 18 gauge double fold GI binding wire and providing Concrete cover blocks to maintain the cover as required. The rate including cost of all materials, bending, tying grills, placing, transportation, lead & lifts, tools & plants, fuels, all materials, labour charges, wastages , laying at all levels, fixing in position, cost of cover blocks and GI binding wires etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 33 Brick work in cement mortar 1:6(one cement and four sand) using fly ash bricks of size 230mmx110mmx70mm for foundation and super structure as per detailed specifications and as directed by the departmental officers 34 Ground Floor 35 First Floor 36 Terrace 37 Brick partition walls of 11.50cm thickness using best quality Fly ashbricks of size 9 x 4-3/8 x 2-3/4(230x115x76) in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) 38 Plastering 10 mm thick for ceiling including slabs, beams and column drops and staircase waist slab, sunshade, drops, chajjas etc.. with cement Mortar 1:3 (1 of Cement : 3 ofP sand) according to the specification. The Rate including Cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 39 Plastering of 12 mm thick for Internal walls with cement mortar 1:4 (1 of cement : 4 of fine P.sand)according to specifications. Rate shall include for providing GI mesh of nominal thickness at the junctions of masonry and concrete works to a width of 100 to 125mm including tying in position with suitable clamps/screws. Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 40 Plastering 12 mm thick for external surfaces with cement mortar 1:4 ratio (1 of cement : 4 of fine P.sand) including water proofing compound of “CICO No.1 or equivalent“ as per Manufacturers Specification with sponge finish (washed sand finish) all complete as per specification and as directed.Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds, grooves to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by theEngineer-in-charge. 41 Supply and painting oftwo coats of Plastic emulsion paint of approved shade and colour over one coat of DCP Primer including one coat of Acrylic Wall Putty with DCP Primer.Rate including all brush, roller, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations,transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by theClient / Engineer-in-charge.(Internal surface) 42 Supplying and painting of2 coats of weather proof exterior emulsion with high sheen, anti algal properties over one coat wall exterior primer of approved quality and shade etc., complete.Rate including all brush, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations,transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 43 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete (M-0652) 44 Supplying and filling the sunken slabarea byBRICK-BATCOBA by adding CICO NO:1 or approved equivalent admixture including applying two coats not less than 2 mm thick of TAPECRETE- AcrylicPolymer Based Waterproof Coating, over the final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with water proofing compound like CICO No.1 at the rate specified in the manufacturers specification after entire completion of laying pipes, sanitary fittings etc.Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, protecting the laid pipes and sanitary fittings, finishing the surface smooth to receive the top coat of water proofing application etc. as complete with all respects complying with relevant standard specification and as directed by theClient / Engineer-in-charge. 45 i) Includingapplying two coats not less than 2 mm thick of TAPECRETE- AcrylicPolymer Based Waterproof Coating, over the plastered surface as including final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with approved water proofing compound like CICO No.1 or approved equivalent conforming to IS 2645 at the rate specified by the manufacturer over coated surfacepreparation of surface, finishing, curing etc. all complete at all levels as per manufacturers specifications and as directed. 46 Supplying and laying of Ceramic tiles of size 305 x 305 x 6mm for flooring approved make and quality with plain/colourwith base mortor in CM 1:3, 10mm thick and pointing with white cement by adding suitable colour pigments including finishing, jointing and polishing with neat finish etc., complete. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 47 Supplying and fixing Dadooing the wall with ceramic tiles of approved quality, colour and design joint free of size 600x300x10mm thick of approved make, in all floors over a base layer of cement mortar 1:2 (one cement: Two sand) 10mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 48 Providing and laying factory-manufactured linoleum flooring in the form of Rolls in the size of 12192mm of length and 1981mm of wide with 2mm thickness which laying above in the vertified tiles using the adhesive the flooring shall be laid over a smooth, level subfloor using manufacturer-recommended adhesives, complete in all respectsRoll flooring shall be laid with butt joints; edges shall be cold-welded or heat-welded for seamless joints.Apply a coat of linoleum polish or sealant after laying (if uncoated variant is used). Proper rolling to remove air pockets and ensure bonding the rate is inclusive of all necessary material, labour, transportation etc asper standards. 49 Finshing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in cement Mortar 1:3 (one cement and threee sand ) 12mm thick mixed with water proofing compound conforming ti ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed withred oxide and water proofing compound including curing et,. complete complying with standard specification and as directed by the departmental officers 50 Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete. 51 Supply and laying with best quality the following materials of Machine Polished granite slab not less than 18 mm thick (Jet Balck) including cutting for wash basin and edge polishing to be set in CM 1:4 (1 of cement : 4 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts working at all levels, transportaion charges, loading & unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing,cleaning, acid wash over finished surface, protection with Gypsum / Poplayeroverplastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge 52 Supplying and fixing plywood partition with Teakwood frames of75x50mm size and with 3mm thick commercial plywood fixedwith screws and nails including fixing in position with 4Nos of iron hold fasts 50x6x230mm size etc.,complete.(ISI STD) 53 Supply & fixing of Tamilnadu Logo & Symbols as per design & Elevation. 54 Flooring with Joint free double charged vitrified tiles of approved quality, colour and design joint free of size 600 x 600 x 8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officers. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by theClient / Engineer-in-charge. 55 Supplying and fixing UPVC windows of casement type Open from the profile the size of outer frame 60mm x58mm and shutter profileare reinforcement withGI/1mm125GSM and 100% Corrosion free,the profiles are multi Chambered sections with wall thick of 2mm. TheEPDM rubber covered with over all the edges of frame and shutter the shutter .will be provided with Espag multi power point locks and also it operates with Handle. The Corners and joint should bewelded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thk should be provided to the shutter and it should not allow leakege of water even at most ranging storms and should have key lockable action, security protective hinges , strong locking system and as per size for arresting noise and energyloss. The connecting mechanism between sash and windowshould be fixed to the wall with 100% packing with screws and silicon Packing all roundthe frames. The window should be got approved from the Executive Engineer before use on work. 56 Providing of 35mm thick factory made pre-laminated ABS(Acrolynitrile Butadiene Styrene) Door Shutter moulded indifferent designs, consisting of all round frame made out of water proof solid foam PVC bar of size 20 x32mm, reinforcedby 32 x 32mm - 2 Nos., for vertical made out of LVL(Laminated Veneer Lumber), core material of 32mm thickhigh density craft paper honey comb board, sandwiched onboth sides with pre-laminated ABS sheet thickness of 1.5mm.PVC edge banding of size 0.45mm on the vertical sides.Hardware made out of steel coated butterfly hinges - 3 Nos.,for each shutter and ISI make SS round lock complete forfinished item of work, complete complying with the standardspecification. The door shutter and frame should be gotapproved from the Executive Engineer before use on work. 57 FRP Door Sutter with FRP Door Frames along with vision panel (as per drawing) made out of FRP Sheets of 3mm thick of over all size 65mm x 50mm with rebate suitably reinforced using MS Angle / Flats, cost of holdfasts and Solid Core FRP Shutter Panel of 5mm thick and hollow core frames of 3m wall thickness for styles and rails etc., of sizes specified by Engineers. 58 Supplying and fixing UPVC Louvered Ventilators of from the profile the size of outer frame 60mm x58mm and shutter profile size of 60mm x 78mm both profile are reinforcement withGI/1mm125GSM and 100% Corrosion free,the profiles are multi Chambered sections with wall thick of 2mm.The EPDM rubber covered with over all the edges of frame and shutter . The Corners and joint should bewelded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thk should be providedin the Louvers.The window should be fixed tothe wall with 100% packing with screws and silicon packing all round the frames.The Ventilator should be got approved from the Executive Engineer before useon work. 59 FALSE CEILING WITH GYPSUM PLAIN TILES (600x600)Providing and fixing true horizontal level false ceiling using SAINT - GOBAIN GYPROC or Equivalent make with 24 mm Grid system using hot dipped galvanised Steel Section, exposed surface chemically cleaned caping prefinished in backed polyestar paint wall angle of size 24mmX24mm used in the periphery of the ceiling fixed to the wall partition R.C. Column bandwalls with the help of screws at 600mmc/c. Main runner of size 32X24mm suspended at 1200mm c/c max by using securely fixed to the structural soffit of R.C.C. slab by using 6mm Nylon Rawl plug at every 1200mm(Max) and 1200mm long Cross Tee of size 24X24mm to interlocked between Mainrunner at 600mm c/c (max) to form a grid of 1200mmX600mm. 600mm long Cross Tee of size 24X24mm is inserted to form a grid of 600mmX600mm and finally tiles laying with 12mm Gypsum plain Tiles as per stansdards 60 Providing & fixing of Brick Cladding in elevation as per drawing. The rate is inclusive of all necessary material , labour, transportation etc complete as per standards. 61 Supplying and Fixing of aluminium Dye Cast Letters of approved size and colour treatment processis achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes aluminium Dye Cast Letters 6 Size. Tamil Stainless Steel Letters 25CM 62 Supplying and fixing M.S.Grill gate of required size in two shutters with necessary iron members, gun metal cups and wheels 75mm dia. with fittings locking arrangements,etc., complete,including painting a priming coat of approved primer,etc., complete (The design of gate furnished is subject to alteration during execution.) 63 Supplying and Painting the wall with Texture Finish Paint including thorough scraping, clean removal of dirt, Primer. The rate includes cost of materials, brushes, sand paper, rollers, plaster of parries, putty wherever required and neat finishing etc., complete complying with standard specification and as directed by the Departmental Officer (the colour and quality should be got approved by the Executive Engineer before use) 64 GYPBOARD DOUBLE SKIN PARTITIONProviding and fixing of Gypsum Dry wall Double skin partition of 75 mm thick using SAINT - GOBAIN GYPROC or Equivalent make and the partition shall be of one layers of tapered edge 12.5mm thk Gyp board screw fixed with dry wall screw of 25mm at 300mm c/c to either side of 48mm studs. GI steel sections to be placed at 610 mm c/c in 50mm floor and ceiling channel 0.55mm thick having equal flanges of 32mm made of GI steel with joints staggered to avoid leakage through joints. Finally square and tapered edges of the boards are to be finished so as to have a flush look which includes filling and finishing with jointing compound, joint paper and 2 coats of Drywall top Coat suitable for Gypsum upto primer level.As per India Gypsum Specs.Note: Angle Bead to be used at external angles to get straight line finish & protection from normal impacts. 65 Providing and laying water proofing treatment to vertical and surfaces for sunken portion of depressed portions of W.C., and the like consisting of :i) 1st course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) 2nd course of 20mm cement plaster 1:2 (1 Cement : 2 Coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) 3rd course of applying blown or residual bitumen applied hot at 1.7Kg per sqm of area. iv) 4th course of 400 micron thick PVC Sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm) 66 PLUMBING WORKS 67 Supply,erection and testing & commisioning of 3HP Submersible pumpset in the capacity of 6000 LPH @ 300Ft, max. total head of 350 Ft pumps fitted with bronze impellers and having delivery size of 40mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge.( Sump to OHT transfer pump) 68 Labour charges for the erection of submersible pumpset in borewell/openwell including fixingand jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days. 69 Drilling of 6 dia vertical borewell so as to have a finished size of 6 dia borewell in boulder area to any required depth as decided by theincluding Transportation from one place to anothr place with in Tamilnadu State by direct or reverse rotary mud circulation method using Contractors rig tools, fuel, labourers, bentonite mud and water required for drilling at the site shown by the TWAD Officers including construction of mud pit etc. using only calyx rigs. 70 300mm 71 Charges for developing the borewell with air compressor of 300 CFM capacity (Minimum 8 Hours) including transportation labour and fuel charges for compressor as directed by TWAD Board Officers and conducting yield test by V notch method. 72 Supply and laying following dia PVC casing pipe with excise duty as per IS 12818 / 1992 73 200mm dia CS ( plain pipe) 74 150mm dia CS ( plain pipe) 75 Labour charges for inserting PVC casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC couplers with cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the Executive Engineer of Departmental officers. 76 200mm dia CS ( plain pipe) 77 150mm dia CS ( plain pipe) 78 Supply and fixing in position whiteEuropean Water Closet of approved make with low level concealed flushing tank 10 litre capacity of best quality and approved make with 100mm P or S trap with double flapped rigid PVC seat cover with CP brass hinges etc. complete complying with standard specification and as directedby the Departmental officers (The EWC should be got approved by the Executive Engineer before use on works.URINAL WITH FIXING ACCESSORIES SET, SIZE - URS-WHT- 13253N 79 Supplying and fixing Wash Hand Basin of size 550 x 400mm with all accessories such as cast Iron Brackets, 32 mm Dia C.P. Waste coupling, Rubber plug and Chain, 32 mm dia B Class G.I. Waste pipe, 15 mm Dia G.M Wheel valve; 15 mm Dia Nylon connection, 15 mm Dia Brass, wast couplingNipples, 15 mm C.P. Pillar tap etc.,including fixing the wash hand basin in the wall in position with a pair of C.I. brackets with teak wood plugs and screws and giving necessary water supply connection and as directed by the Department officers.(TheWash basin should be got approved by the Executive Engineer before use on works. 80 Supplying and fixing of CP Two Way Bib Cock with Health Faucet ,wall hook & one metre longflexibletubeincludingcuttingandmakinggoodthe wallswherever requiredetc complete.complyingwithstandardspecificationandas directedbytheDepartmentofficers.Thequalityandmakeofhealth faucet should be got approvedby Concern department Engineer before use on work. 81 Supplying and fixing the best quality approved make of SS heavy duty long body Tap including cutting and making good walls wherever required etc.complete,complying with standerd specification and as directed by the department officers. The quality and make of angular stop cock should be got approved by concern department engineer before use on work. 82 Supplying and fixing in position Mirror of size 600x450mm of approved quality and brand with necessary plastic back PVC frame with bottom stand using brass screws rawl plugs for fixing etc complete complying with standard specification and as directed by the Departmental officers.The colour of frame and quality of mirror should be got approved by the Executive Engineer before use on work 83 Supplying,installing,testing and commissioning of approved make CONCEALED STOP COCK for toilet including neccesary accessories etc,complete,works include making require size curout in wall,and fixing the control box property,redoing the same etc,complete the quality and make of concealed stop cock should be got approved by concern department Engineer before use on work. 84 Supplying and fixing CP angle cock with wall flange including cutting and making good the walls wherever required etc., complete complyingwithstandardspecificationandas directedbythe Engineer Incharge before use on work. 85 Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg ,10 kg /sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). 86 160mm Dia 6kg 87 110mm Dia 6kg 88 75mm Dia 6kg 89 50mm dia 6kg 90 Supplying andfixingPVC cowl of following size to vertical Soil/Waste pipes above terrace level. The rate including cost of all materials, labour charges and transportation etc. completed as directed by Engineer-in-Charge. 91 110mm dia 92 Supplying & fixing in position PVC Nahini / Floor trap of size 100x75mm including stainless steel gratings of approved brand & quality, fixed over a bed of brick jelly limeconcrete 1:2:5 ( One part of lime, two parts of sand & five parts of 40 mm size brick jelly ) & finished with cement mortar 1:3 ( One cement & three sand ) includingdismantling masonry works wherever found necessary & making good the damaged portions to the original condition & giving connections to the cast iron pipes etc., complete, complying with standard specification. (The PVC Nahini / Floor trap should be got approved by the Executive Engineer before use on works ). 93 Constructing solid block masonry manhole various size of deep in cement mortar 1:3( 1 Cement: 4 coarse sand ) R.C.C. Raft & top slab with cement concrete 1:2:4, plain cement concrete 1:4:8 mixfor base course (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size )above that 150 mm thick RCC M25 raft slab inculding reinforcement 10mm dia 150mm c/c bothways. Plastering inside walls with 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand ) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ), finished with a floatingcoat of neat cement ,supplying and fixing SFRC manhole cover with farame , PVC foot rest as per detailed drawing etc the quoted rate shall also necessary excavation and back filling etc complete.complete as per standard design : (the chamber and cover should be got approved by the Executive Engineer before use on works) 94 Manhole 600 x 600 mm internal size ( Depth up to 1000mm) 95 Supplying, laying and jointing CPVC pipes SDR 11(having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using CPVC adhesivesand fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The CPVC pipes shall be got approved by Executive Engineer before use on works.Internal & Vertical 96 a) 20 mm dia 97 b) 25 mm dia 98 c) 32 mm dia 99 Supplying and fixing manhole cover with frame as per approved make ,cover weight and being size mentioned below and specified size in the drawing etc., including painting with two coats of anticorrosive paint over a coat of primer etc., fixing locking arrangements, fixing Man-hole over, grouting the anchors with CC 1:2:4 (one cement,two fine aggregate and four coarse aggregate), as complete in all respects complying with relevant standard specifications and as directed by theClient / Engineer-in-charge.Size:600x600mm 100 Supply & fixing of Bottle trap as per standards. BOTTLE TRAP (WITH INTERNAL PARTITION) 32 - ALD-CHR- 769L300X190 101 LANDSCAPING WORKS 102 Planting of Ixora hybrid foliage shrub variety of height 30-45 cm in polythene bag of size 6x8 inchincluding loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 103 Planting of Ficus black ornamentalfoliage shrub varietyof height 30-45 cm in polythene bag of size 6x8 inch including loading and unloading charges, transportation,stacking of saplings at site, earth work excavation ofrequired size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 104 Planting of Jasmine Plant foliage shrub varietyof height 30-45 cm in polythene bag of size 6x8 inch including loading and unloading charges, transportation,stacking of saplings at site, earth work excavation ofrequired size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 105 Planting of Travellers palm ornamental foliage Specimen plantvarietyof height 105-120 cm in polythene bag of size 16x16 inch including loading and unloading charges, transportation,stacking of saplings at site, earth work excavation ofrequired size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 106 FURNITURE WORKS 107 Linear type Workstation (1000mm(W) X 600mm(D) X 750+300mm(H)) as per below specificationTable Top: - Made of 25mm Thick E1 Grade Pre-Laminated Particle Board with 2mm PVC Edge Banding.Main Screen : -8mm Sandwitch Glass finishes of Sizes 1050x300mm htUnderstructure: - MS Square Leg cross-section of size 50 x 50mm is Made of Mild Steel 1.6mm thick CRCA Powder coated.MS Powder Coated horizontal Beams supported below the table top of Size 50*25mm. Rectangular Tube made of 1.6mm thick CRCA Powder coated.Raceways : -Vertical Raceways - 120 MM HT MS Powder Raceways Considered below the Table top With Intermediated legs considered for Wire Provision.Without Middle Cover.Wire Manager: - Wire Manager Hole considered. 108 Storage (Open Shelf) 1200mm 300mm 2100mmIs made 25mm top & all other panel 17 mm thick in prelam particle board finished in Laminate of approved shape, equal shutter 2mm thick edge banding finished. This also includes providing and fixing of hardware like locks, handles, spring loaded hinges etc 109 Supply of Chairs 110 ASPIRE MB (BLACK)* Black Backrest frame, Polished aluminum connected* Mesh back, Seat and headrest fabric* Height adjustable lumbar support with PU surface* Tiltable backrest (can be tiltable when locked inupright position)* 4D adjustable armrest with PU pads* Mould foam with plastic seat upholstery* Mechanism, with seat slide.* Chrome gaslift* Polished aluminum base with plastic cover,* 60mm nylon castors 111 * Versa Medium Back Mesh Chair* AN -70 Mesh* Single Lock Synchro Mechanism* Adjustable Lumbar Support* One Way Adjustable Armrests ( Height)* Nylon Base* Fabric Upholstered Cushion Seat 112 Meeting Room TableTable Top: -Made of 25mm Thick E1 Grade Pre-Laminated Particle Board with PVC Edge Banding,Understructure: - MS Leg 50mm 50mm is Made of Mild Steel 1.6mm thick CRCA Powder coated.MS Powder Coated horizontal Beams supported below the table top of Size 50*25mm.Raceways : Horizontal RacewaysMS Powder Raceways Considered below the Table top With Intermediated legs considered for Wire Provision.Wire Manager:- Flip Cover Considered. 113 Meeting Room Table (2400mm 800mm 750mm) 114 Cabin Main Table with Side Storage (Main Table 1500mm 750mm 750mm / Side Storage 1200mm 450mm 750mm)Side Storage 1200mm 450mm 750mmTable Top: Main and Side Table Made of 25mm Thick E1 Grade Single Top PLPB with 2mm PVC Edge Banding,Understructure: MS Square 50mm Steel 1.6mm thick CRCA Powder coated.MS Powder Coated horizontal Beams supported below the table top of Size 50mm x 25mm.Flip Cover : Flip Cover 400*143mm Made of AluminiumWire Manager: Wire Box with Socket Plate and Vertebra considered for wiringModesty : Front & Side PLPB Modesty Panel . 115 Librarian TableMain Table 1100mm 440mm 750mm 116 3 Seater Sofa with Table 117 INTERACTS-902 (Leatherette)3 SeaterSize : 1810 (W) x 720 (D) X 740 (H)Made off : the sofa is made of fine quality leatherrite (3s = 8.0 mtr,2s = 6.8 mtr, 1s= 5.3 mtr), the structure is made from silver wood& pine wood, 32 & 40 density foam is used which is covered withroll poly filling for giving comfort and extra softness to sofa. Extra(kangaro company)Legs : are made of stainless steel.Color : Black 118 ELECTRICAL 119 TNEB METER BOX 120 Supply andfixng of TNEB meter board suitable for 3phase100A service connection made up of suitable angle iron frame work of size 2feet x 1-1/2 feet using angle iron of size1-1/2x1-1/2x1/4rigidly fixed on wall covered with hylem sheet of size 2 feet x 1-1/2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3Nos.100A fuse units (500V), 1No .neutral link,copper earth flat of size1x1/4with inter connection of EB meter to fuse units by 16 Sq.mm PVC insulated copper wire with earth connection complete. 121 M.S. Enclosure (IP65): Supply, Erection , Testing and commissioning of the followingtype M.S. powder coated enclosure for housing the Meteringing service, whch should be made outof16SWG enclosure with provision for cable entry, with Outdoorapplication IP65 as specified Protection, fixed on the wall/Floor withall accessories, pedestal frame with concrete grouting or suitable to fix at concrete plinth etc. 122 MAIN Panels 123 MAIN Panels:Supply, Installation, testing and commissioning of 3Phase, 415Volts, Main LT Panel board of Indoor, Cubicle floor mounting type made out of14 SWG CRCA sheet steel with powder coated finishing, MS base frame, double internal earthing arrangements, 100Amps, rating TPN Copper busbars and Earth bar with interconnection busbar, etc., comprising of the followings:EB Incomer :1 No. 100Amps, 25kA, 4Pole, Thermal magnetic MCCB with Ext.RHOMDG Incomer: 1 No. 100Amps, 25kA, 4Pole, Thermal magnetic MCCB with Ext.RHOMCommon C/O Incomer: 1 No. 100Amps, 4Pole Automatic Changeover Switch with EB ON and DG ON LED Indication lampsMetering : 2 Set of RYB LED Indication lamps2 Nos. of Multifunction Meter with RS 4852 Set of Current Tranformers (200/5A, Cl-1), 1 No. 200/5A CT for APFCR2 Set of Control MCB and Electrical Interlocking between EB & DG Incomers Outgoings: 3 Nos. 63A, 25kA, TP+N, TM MCCB with Ext. RHOM (APFCR &AC)4Nos. 32A, 25kA, TP+N, TM MCCB with Ext. RHOM (Lighting & Spare),6Nos 32A DB MCB inclding all labour Charges And Transports Charges. 124 APFC PANEL: Supply, installation, testing and commissioning of 25 KVAR Automatic power factor correction panel ( APFC ) with 8 steps of capacitor switching cubicle type, free standing, Powder coated, 14 SWG CRCA sheet steel,enclosed separate compartment for each capacitor, front operated, indoor type dust and vermin proof, hinged, lockable doors, electrolytic grade aluminium bus bars, with SMC /DMC insulator supports, Digital volt meter, Ammeter with selector switch, 8 stage Digital Automatic power factor correction,( APFC ), Auto / Manual selector switch, cluster LED typeindicators, in the incomer,complete with electrolytic grade aluminium bus bars, MPP type Power capacitors, with 5 KVAR x 3 no. 3 KVAR x 2 nos. 2 KVAR x 1 nos. 1 KVAR x 2no. Contactors, MCCB’s, start, stop, push buttons, internal wiring, colour coding, ferrules, cable gland plates, Aluminium earth bus for the entire length of the panel with bonding to earth and painting,Panel mounting MS Channels, fasteners, etc., including all associated control wiring and interlocking circuitry, Main panel sensing CT interconnecting wiring etc., all inclusive. 125 Supply, Installation, testing and commissioning of 1 x 58.5KVA, Silent type Diesel Generator Set with AMF Panel complete with suitable size Acoustic enclosure CPCB IV and BIS. Diesel Engine suitable for Generator application, developing 1500RPM with an overloading capacity of 10% for one hour in any 12 continuous hours operation generally confirms to BS:5514, directly coupled to 58.5KVA at 0.8 Power factor, 415V, 3Phase , 4wires, 50cycles per second self excited, self regulated, with brushless excitation, Alternator generally confirms to BS:5000/IS:4722. DG set shall be complete with radiator, residential type silencer, electronic governor, cable termination box, MS mounting frame, fuel piping, diesel day tank, 24VDC Battery, Battery mounting frame, oil level indicator with gauge board, andall other accessories as per standard specifications.Diesel Generator set shall be mounted on cushy foot or similar type of vibration Isolators. The cost of Exhaust pipe shall be included in this item with Sutable concrete Base at M30 Grade. The DG Set shall be suitable for auto-mains failure startand auto / manualoperations.The DG Should be supplied with Auto-Start-Stop Control panel with suitable rating switchgear 126 DISTRIBUTION BOARDS 127 Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1no. 32A DP MCBswitch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wallwith earth connection only.Higher End 128 Supply and fixing of 4 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution boardwith double door (metal) with 1 no. 32A 4P MCB switch as incoming and 12 nos. 6A to 32A SP MCB asoutgoing in flush with wall with earth connection only. Higher End 129 Supply and fixing of 7 segment 4 way TPN MCB sheet steel distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one no. 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one no. 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 4 ways in each segment) and seperate provision for MCB / Isolators ( totally 12 nos.) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm.with the following in flush with wall with earth connection only. i. 63A 4P MCB - 1 no.ii. 63A 4P 30MA RCCB/ELCB - 1 no.iii. 63A DP MCB Isolator -3 nos.iv. 6A to 32A SP MCB - 12 nos., 130 Supply and Laying of 3 1/2x 70 sq.mm. PVC armoured LTUG cablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 131 Supply and fixing of brass cable gland for 3-1/2 x 70 sq.mm. PVC armoured LTUG cable with earth connection. 132 Supply and providing cable end termination of 3-1/2 x 70 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete. 133 Run of Mains 134 Supply and Run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed position. 135 Supply and Run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed FRLS copper wire and making good of the concealed portion. 136 Supply and Run of 2 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed position. 137 Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion. 138 Point Wiring 139 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) Higher End Primary Point. 140 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator)Higher EndSecondary Point. 141 Switch & Sockets 142 Supply and fixing of 1 no.6A two module 5 pin socket , 1 no.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 143 Supply and fixing of 2nos.6A two module 5 pin socket , 2 nos.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 144 Supply and fixing of 1 no.6/16A two modulesocket , 1 no.16A one module switch with module cover plate (plastic) on Suitable module concealedBox (GI ) in flush with wall with connections. Higher End 145 Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug in flush with wall with earth connection (For AC Plug) 146 Air Condition 147 Supply & Instalation of Air-Conditioner with Copper Coil 2.0 TR Split Type AC Unit - 5 Star Rated, 5 KVA capacity Automatic Voltage Stabilizer with time delay relay, 5/8” and 3/8” copper pipe (Extra beyond 3 metres supplied with AC unit), Inculding MS stand for fixing outdoor unit. 148 Supply and fixing of Copper Refrigerant Piping of 3/8 dia and 5/8with Pipeline nitrle rubber insulation with 50mm PVC water drain pipe line with Non Adhesive Cotton Roll insulation and 3 core Power cable from indoor to Outdoor unit. 149 Supply and fixing of 450mm (18) Wall mounting 5 star rated complete (Higher end) with necessary accessories and hardwares as required. 150 Supply and fixing of 300mm (12) sweep(Heavy Duty) AC exhaust fan complete with necessary wall opening and making good of the wall . 151 Supply and fixing of louvers shutters arrangements for 300mm (12) sweep AC exhaust fan 152 Supply and fixing of 24W LED 2x2 square type Recessedfitting with LED (Higher end) on false Ceiling with suitable hanging support from ceilingwith PVC unsheathed copper leads from terminals to the fitting 153 Supply and fixing of 18W LEDRound type Recessedfitting with LED (Higher end) on false Ceiling from ceilingwith PVC unsheathed copper leads from terminals to the fitting. 154 Supply, installation, testing and commissioning of36 W, 900mm diaCircular LED pendantlight fitting, made out of CRCA powder coated body, aluminium reflectors,poly methyl meth acrylate (PMMA) diffuser, glare free light, suitable for recessed mounting including electronic drivers, day light colour LED lamps, inter connecting wiring including accessories all inclusive. KL 3232 155 Supply and fixing of28Watts GATE FIXTURE FITTINGwith cool day light suitable for wall / roof sheet mounting, made outCRCA powder coated body,IP65 aluminium reflectors,poly methyl meth acrylate (PMMA) diffuser, glare free light, including electronic drivers, day light colour LED lamps, inter connecting wiring with suitable fixing clams, hooks as required including accessories all inclusive.(Klite/Millenium/Bajaj Equivalent) 156 Supply and fixing of 8W Light fitting (IP67) Inground fixture with PVC unsheathed copper leads from terminals to the fitting and to complete necessary accessories and etc to complete the work. (Klite/Millenium/Bajaj Equivalent) 157 Supply and fixing of MIRROR Light 20W LED Batten 158 Supply and erection of Canon Digital Photocopier (Xerox) Machine IR-3300 / 3235Type of Product : Laser Multi functionalCore Functions: Print, Copy, Scan & SendFirst Copy Time:3.9 SecMultiple Copies :1 to 999 SheetsPrint Speed :45ppmThe laser beams engrave the image or text that you have sent to print on the surface of the drum. When using a copier this process is done using light, the light scans the page required for printing and converts it into an image 159 Supply and erection ofAll-in-one Desktop of HP 27-cb1456in Core i5 (8GB DDR4 /Windows 11 Home/27 Inch Screen/27-cb1456in) with 600VA UPS, Keyboard, Mouse,27 inches, 11th Gen Intel Core i5-1235U6 x 1.8 GHz (Turbo Speed upto 4.2 GHz) Cores Hexa Core, 12 Threads, 18 MB Cache, UHD Graphics 730 Graphics, 8 GB DDR4 RAM Smallest and 512 GB SSD.Ethernet (LAN), HDMI, Multi Card Reader,WiFi, Bluetooth v5.03 x USB 3.0, 1 x USB Type-C and Inbuilt Microphone 160 PRINTER: Supply, installation, testing and commissioning of HP Smart Tank 790 WiFi All-in-One Printer Duplexer with ADF and Magic Touch Panel Inkjet Colour printer, print speed 11-20 sheets with multiple features like print, scan, copy, fax, multi-port connectivity (Hi-speed USB 2.0, Wifi, Bluetooth LE , 1 USB Host, LAN) , 2.4/5G dual band Wi-Fi, Wi-Fi Direct, mobile printing capability, etc 161 Supply, installation, testing and commissioning of Long Range Wifi Device of following Specification: Networking Interface: (1) GbE RJ45 PortPower Method: PoE+, Pasive poE(48V) Max TX power: 2.4 GHzAntenna gain: 2.4 GHzMounting: Wall or Ceiling MountingWifi Satndards : 802.11a/b/gWireless security: WPA-PSK, WPA- Enterprises(WPA/WPA2/WPA3)VLAN: 802.1Q Concurrent Clients: 300+ 162 CCTV 163 Supply, Installation, Testing and commissioning of 16 channel 2 SATA NVR, with 6TB Hard Disk Drive 2 nos, New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected,Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output  HDMI1 / VGA1 outputs provided  HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface for HDD connection, Support upto 10TB capacity for each HDD, Smart search for efficient playback. and smart playback to improve the playback efficiency, Supports VCA search for fire/ship/temperature/temperature difference detection triggered video files, POS information overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access  Hik-Connect for easy network management, 2 Gigabit Ethernet network interfaces. (Make : Hikvision / Dahua / Sony. 164 Supply of 4MP, Internet Protocol fixed BULLET CAMERA/DOME CAMERA (INDOOR & OUTDOOR)with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behaviour analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse. with Camera Stand and camera fixed connecting box. (Make: Dahua/Panasonic) 165 Supply, Installation, Testing and Commissioning of 32 smart LED TV with following specifications a) Full HD 1920 x1080 (4K monitor) b) IPS panel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -3nos n) Built in LAN (Make: Sony/ LG /Samsung). 166 Supply and Clamping of CAT 6 unarmoured cable in suitable PVCPipe 1 thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem)i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal)IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-TIEEE 802.5 16 MB; ISDN; TPDDI; ATMii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant. ii)Fire Rating: PVC : IEC 60332-1.iii. Conductor - Bare Copper Wireiv. Insulation - Polyethylene v. Twisting - 2 Cores to the pair vi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm. 167 Supply and Fixing of Rack with Accessories -Higher end9U Rack with fan extra for the above rack. (Amp/NVR/POE) 168 Supply and Fixing of Rack with Accessories -Higher end4U Rack with fan extra for the above rack. (speaker/data/cctv) 169 Supply and fixing of POE 24 port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. (Make: DLINK,NETGEAR/ TPLINK) 170 Supply and fixing of POE 8 port switch with two uplink port, 10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. (Make: DLINK,NETGEAR/ TPLINK) 171 Supply and fixing of outdoor4X6PVC box with 102mm x 77mm x 102mm with all fixing accessories. 172 Supply, Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point ( Point to Point ) Crimping, Testing and arrangement charges. 173 Supply and Installation for 1KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2 Hours back up and battery stand . 174 Supply, Erection of 6mLengthpole with base plate of size 300x300x12mm as per IS-875 with following specification. Pole Outter dia -76.10mm x 3.65mm Thick x 6 meter with foundation Charges. 175 VOICE & DATA 176 Supply, Fixing and Termination ofRJ 11 Single Point ( Point to Point) Crimping, Testing and arrangement charges. 177 Supply & Installation of CAT 6 PVC Module Box I/o socket & face plate single socket Erection and arrangement chargers (Higher end) 178 Supply and fixingofLAN Network Switches Un-Managed 10/100/1000 - 24 Port and 24 Port Patch Panel- Unloaded erection and arrangement chargers. 179 Supply, runing, testing and commissioning of2 Pair Unarmoured 0.5mm Telephone cable in suitable Pvc Rigid pipe concealed on wall and ceiling with continuous earth wire connection with painting of suitable colour. 180 PA SYSTEM 181 Supply, Installation,Testing & commisioning of 15W Wall Speaker 2 way high efficiency, high fidelity, long throw IP65 weather proof P.A Music Horn speaker. It combines the high efficiency of horn with wide frequency response.Music horn is weather protected and UV protected ABS plastic housing combines with the feature of easy poertap selection on a terminal strip with a two core cable.It has impedence of 250/500/1k/2k ohm with frequency response of 120-16000 hertz. (Make:AhujaAMH402T/Bosch or its equivalent) 182 Supply, Installation,Testing & commisioning of 120 watts P.A Mixer Amplifier with the output power of 120 watts maximum 160watt rms at 10% Thyristor harmonic distortion(THD), 850watt RMS at 5% THD, 800 wattsRMS at 2% THD and the power supply AC voltage ranging from 220-240 volt, 50/60 hertz. with the DC input of 48 volt and 1000watts has tone controls of Bass=+- 10 db at 100 hz weighing 42kg with the speaker output of2Q,4Q.70volt&100volt has power consumption of 1600VA AC &12A DC and 100db output regulation at 1khz no load to full load ratio. The signal to noise ratio is 60db with the imnput channels of 0.8mv/4.7kq,3*Aux 100mv/50kq.The frequency response of 50-15000hz+-3db.(Make:Ahuja SSA 10000/Bosch) 183 Supply, runing, testing and commissioning of2Core x 1.5sq sqmm PVC insulated un Armoured Speaker Cable in suitable 20mm dia Pvc Rigid pipe concealed on wall and ceiling with continuous earth wire connection with painting of suitable colour. 184 Earthing 185 Earthing as per the ISI specification with an earth electrode of 2.10 metre Class B GI pipe of dia not less than 40mm withcopperearthplateofsize125mmx50mmx6mmwithnecessaryfunnellingarrangementswithnecessary masonry work and with 38mm RCC cover slab for the brick masonry 186 Supply and erection of 17.2mm, 3mtr long, Copper Bonded earth rod with backfill compound, including civil worksof base PCC for chamber andheavy duty Chambercover,, heavy duty chamber cover, etc., as per IS 3043 standards 187 Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection 188 Supply and Run of1 of No.8 SWG copper wire for earth connection 189 Supply and Run of1 of No.8 SWG copper wire in suitable PVC rigid pipeon wall / floor / ground for earth connection 190 Supply of 2mx1mRubberMatsuitablefor11KVinstallation confirming to IS(5 Nos) 191 Supply of First Aid Box complete with all First Aid Medicines 192 Supply and fixing of Shock Treatment chart with Glass frame 193 Supply and fixing of4 Nos. Fire Buckets made out of 40 x 40 x 6mm MS Angle 194 Supply and fixing of Fire Extinguishers Co2, 4.5Kg confirming to TAC norms 195 Supply and fixing of Metallic Danger Board as required by the Electrical Authorities 196 METAL SIGNAGE BOARDS: Supply and fixing of metal signages for the following:1. Mudhalvar Padaipagam text in Tamil of size 20 x 15with backlit LED placed over the base, fabricated using stainless steel sheet of minimum 16G thickness brush finish of required size and colour as required. 197 LOGO SIGNAGE BOARD 198 LOGO SIGNAGE BOARDS: Supply and fixing of acrylic signages for the following:1. Mudhalvar Padaipagam logo of size 2 x 22. CMDA logo of size 2 x 33. Directorate of Public Libraries logo of size 3 diawith backlit LED placed over the sun board base, SIDE EDGES(4): 5mm transparent white acrylic sheet with laser cut & 4inches manual raising all around with details. ACRYLIC SHEETS & ITS TECHNICAL PARAMETERS:Front: a. 5mm Imported (Mitsubishi/equivalent) acrylic cutting on laser cutting machine.b. Flexi bond make 25mm Sun board for the back of the logo.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
25.
Health and Family Welfare #10187107 Price Bid
Tender For Electrification Work In Phc Building At Moriya District Phalodi - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 25 mm 82 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 84 150 mm dia per running inch length 85 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 86 4 kVA 87 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 88 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 Surface Mounting (with extruded alumn. Housing ) 90 Minimum lumen output 1950 lm 91 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 93 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kg 95 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 15 Ltr. 97 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 98 2 pair 99 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 10 Pairs 101 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 102 RJ-11 telephone jack singleline 103 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 104 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 105 Cat 6, Un-sheilded Information Outlet 106 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Single Aperture 108 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 110 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 Modular Patch Panel Loaded with Cat -6 I/O 112 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 24 Port 114 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 115 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 116 Recessed Mounting 117 Minimum lumen output 4200 lm 118 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 119 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 120 1 Mtr 121 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 122 3.5 x 25.0 sq.mm 123 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 125 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 126 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 127 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 128 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 130 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 131 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 132 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 133 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 134 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 135 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 136 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 137 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 138 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 139 Ring type tape wound CT 140 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 141 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 142 Red/yellow/Green colour 143 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Electrolytic grade Aluminium bus bar 6010 grade
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
26.
Health and Family Welfare #10187103 Price Bid
Tender For Electrification Work In Phc Building At Bhudkiya District Jodhpur Rural - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 25 mm 82 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 84 150 mm dia per running inch length 85 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 86 4 kVA 87 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 88 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 Surface Mounting (with extruded alumn. Housing ) 90 Minimum lumen output 1950 lm 91 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 93 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kg 95 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 15 Ltr. 97 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 98 2 pair 99 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 10 Pairs 101 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 102 RJ-11 telephone jack singleline 103 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 104 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 105 Cat 6, Un-sheilded Information Outlet 106 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Single Aperture 108 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 110 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 Modular Patch Panel Loaded with Cat -6 I/O 112 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 24 Port 114 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 115 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 116 Recessed Mounting 117 Minimum lumen output 4200 lm 118 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 119 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 120 1 Mtr 121 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 122 3.5 x 25.0 sq.mm 123 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 125 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 126 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 127 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 128 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 130 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 131 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 132 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 133 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 134 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 135 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 136 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 137 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 138 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 139 Ring type tape wound CT 140 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 141 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 142 Red/yellow/Green colour 143 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Electrolytic grade Aluminium bus bar 6010 grade
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
27.
Health and Family Welfare #10187085 Price Bid
Tender For Electrification Work In Bphu And Bphl At Chc Manihari Block Pali District Pali - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 11 20 mm 12 25 mm 13 32 mm 14 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 2 x 2.5 sq. mm. + 1x1.5sqmm 16 1 x 4.0 sq.mm 17 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 18 4 x 6.0 sq.mm 19 4 x 10.0 sq.mm 20 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 21 1.2 mm thickG Iboxes 22 100mm x 100mm x 60mm 23 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 3.0 mm thick 25 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 26 75 mm dia 27 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 Single pole MCB (With B/C curve tripping Characteristics) 30 6 A to 32 A rating 31 Four pole MCB (With B/C curve tripping Characteristics) 32 50/63 A rating 33 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 34 Metal door (Three phase) IK-09 and IP-43with Metal end box 35 8 Way 36 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 37 Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box 38 4 Way 39 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure A attached with this BSR 42 IP -67 Surface/Wall mounted socket 43 32 A 3 pin(2P+E) 44 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 45 5 step fan regulator 2 Module 360 dgree rotating 46 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 47 4 pole MCCB With Thermal Magnetic release 48 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 49 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 50 50.0 Sq. mm 51 3.5 core 52 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 53 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 54 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 55 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 56 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 57 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 58 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 59 17.2 mm thick and 3 Mtr. Long 60 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 25mm x 3mm Alum. Strip 62 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) 64 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 300 mm sweep(900/1400 RPM) 66 380 mm sweep(900/1400 RPM) 67 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 Up to 380 mm size 69 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 70 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 71 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 72 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 Surface Mounting (with extruded alumn. Housing ) 74 Minimum lumen output 2400 lm 75 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 LED Street Light fixture with Minimum lumen output 8700 lm 77 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 32 mm Dia. 79 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 Cat 6, Un-sheilded Information Outlet 82 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Single Aperture 84 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 86 2 Mtr 87 Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic,should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 12 Ports 90 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.5 TR ISEER not less then 3.8 93 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kVA 95 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 96 100 mm dia per running inch length 97 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 20 mm 99 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 101 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
28.
Health and Family Welfare #10187079 Price Bid
Tender For Electrification Work In Bphu And Bphl At Chc Sadri Block Desuri District Pali - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 11 20 mm 12 25 mm 13 32 mm 14 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 2 x 2.5 sq. mm. + 1x1.5sqmm 16 1 x 4.0 sq.mm 17 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 18 4 x 6.0 sq.mm 19 4 x 10.0 sq.mm 20 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 21 1.2 mm thickG Iboxes 22 100mm x 100mm x 60mm 23 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 3.0 mm thick 25 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 26 75 mm dia 27 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 Single pole MCB (With B/C curve tripping Characteristics) 30 6 A to 32 A rating 31 Four pole MCB (With B/C curve tripping Characteristics) 32 50/63 A rating 33 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 34 Metal door (Three phase) IK-09 and IP-43with Metal end box 35 8 Way 36 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 37 Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box 38 4 Way 39 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure A attached with this BSR 42 IP -67 Surface/Wall mounted socket 43 32 A 3 pin(2P+E) 44 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 45 5 step fan regulator 2 Module 360 dgree rotating 46 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 47 4 pole MCCB With Thermal Magnetic release 48 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 49 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 50 50.0 Sq. mm 51 3.5 core 52 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 53 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 54 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 55 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 56 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 57 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 58 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 59 17.2 mm thick and 3 Mtr. Long 60 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 25mm x 3mm Alum. Strip 62 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) 64 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 300 mm sweep(900/1400 RPM) 66 380 mm sweep(900/1400 RPM) 67 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 Up to 380 mm size 69 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 70 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 71 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 72 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 Surface Mounting (with extruded alumn. Housing ) 74 Minimum lumen output 2400 lm 75 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 LED Street Light fixture with Minimum lumen output 8700 lm 77 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 32 mm Dia. 79 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 Cat 6, Un-sheilded Information Outlet 82 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Single Aperture 84 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 86 2 Mtr 87 Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic,should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 12 Ports 90 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.5 TR ISEER not less then 3.8 93 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kVA 95 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 96 100 mm dia per running inch length 97 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 20 mm 99 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 101 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
29.
Health and Family Welfare #10187077 Price Bid
Tender For Electrification Work In Bphu And Bphl At Chc Takhatgarh Block Sumerpur District Pali - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 11 20 mm 12 25 mm 13 32 mm 14 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 2 x 2.5 sq. mm. + 1x1.5sqmm 16 1 x 4.0 sq.mm 17 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 18 4 x 6.0 sq.mm 19 4 x 10.0 sq.mm 20 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 21 1.2 mm thickG Iboxes 22 100mm x 100mm x 60mm 23 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 3.0 mm thick 25 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 26 75 mm dia 27 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 Single pole MCB (With B/C curve tripping Characteristics) 30 6 A to 32 A rating 31 Four pole MCB (With B/C curve tripping Characteristics) 32 50/63 A rating 33 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 34 Metal door (Three phase) IK-09 and IP-43with Metal end box 35 8 Way 36 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 37 Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box 38 4 Way 39 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure A attached with this BSR 42 IP -67 Surface/Wall mounted socket 43 32 A 3 pin(2P+E) 44 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 45 5 step fan regulator 2 Module 360 dgree rotating 46 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 47 4 pole MCCB With Thermal Magnetic release 48 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 49 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 50 50.0 Sq. mm 51 3.5 core 52 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 53 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 54 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 55 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 56 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 57 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 58 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 59 17.2 mm thick and 3 Mtr. Long 60 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 25mm x 3mm Alum. Strip 62 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) 64 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 300 mm sweep(900/1400 RPM) 66 380 mm sweep(900/1400 RPM) 67 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 Up to 380 mm size 69 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 70 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 71 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 72 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 Surface Mounting (with extruded alumn. Housing ) 74 Minimum lumen output 2400 lm 75 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 LED Street Light fixture with Minimum lumen output 8700 lm 77 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 32 mm Dia. 79 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 Cat 6, Un-sheilded Information Outlet 82 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Single Aperture 84 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 86 2 Mtr 87 Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic,should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 12 Ports 90 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.5 TR ISEER not less then 3.8 93 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kVA 95 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 96 100 mm dia per running inch length 97 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 20 mm 99 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 101 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
30.
Health and Family Welfare #10187074 Price Bid
Tender For Electrification Work In Bphu And Bphl At Chc Dhawa, Block Dhawa District Jodhpur Rural - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 11 20 mm 12 25 mm 13 32 mm 14 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 2 x 2.5 sq. mm. + 1x1.5sqmm 16 1 x 4.0 sq.mm 17 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 18 4 x 6.0 sq.mm 19 4 x 10.0 sq.mm 20 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 21 1.2 mm thickG Iboxes 22 100mm x 100mm x 60mm 23 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 3.0 mm thick 25 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 26 75 mm dia 27 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 Single pole MCB (With B/C curve tripping Characteristics) 30 6 A to 32 A rating 31 Four pole MCB (With B/C curve tripping Characteristics) 32 50/63 A rating 33 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 34 Metal door (Three phase) IK-09 and IP-43with Metal end box 35 8 Way 36 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 37 Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box 38 4 Way 39 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure A attached with this BSR 42 IP -67 Surface/Wall mounted socket 43 32 A 3 pin(2P+E) 44 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 45 5 step fan regulator 2 Module 360 dgree rotating 46 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 47 4 pole MCCB With Thermal Magnetic release 48 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 49 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 50 50.0 Sq. mm 51 3.5 core 52 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 53 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 54 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 55 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 56 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 57 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 58 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 59 17.2 mm thick and 3 Mtr. Long 60 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 25mm x 3mm Alum. Strip 62 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) 64 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 300 mm sweep(900/1400 RPM) 66 380 mm sweep(900/1400 RPM) 67 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 Up to 380 mm size 69 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 70 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 71 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 72 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 Surface Mounting (with extruded alumn. Housing ) 74 Minimum lumen output 2400 lm 75 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 LED Street Light fixture with Minimum lumen output 8700 lm 77 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 32 mm Dia. 79 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 Cat 6, Un-sheilded Information Outlet 82 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Single Aperture 84 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 86 2 Mtr 87 Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic,should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 12 Ports 90 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.5 TR ISEER not less then 3.8 93 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kVA 95 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 96 100 mm dia per running inch length 97 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 20 mm 99 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 101 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
31.
Health and Family Welfare #10187067 Price Bid
Tender For Electrification Work In Bphu And Bphl At Chc Bhaniyana Block Bhaniyana District Jaisalmer - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 11 20 mm 12 25 mm 13 32 mm 14 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 2 x 2.5 sq. mm. + 1x1.5sqmm 16 1 x 4.0 sq.mm 17 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 18 4 x 6.0 sq.mm 19 4 x 10.0 sq.mm 20 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 21 1.2 mm thickG Iboxes 22 100mm x 100mm x 60mm 23 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 3.0 mm thick 25 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 26 75 mm dia 27 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 Single pole MCB (With B/C curve tripping Characteristics) 30 6 A to 32 A rating 31 Four pole MCB (With B/C curve tripping Characteristics) 32 50/63 A rating 33 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 34 Metal door (Three phase) IK-09 and IP-43with Metal end box 35 8 Way 36 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 37 Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box 38 4 Way 39 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure A attached with this BSR 42 IP -67 Surface/Wall mounted socket 43 32 A 3 pin(2P+E) 44 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 45 5 step fan regulator 2 Module 360 dgree rotating 46 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 47 4 pole MCCB With Thermal Magnetic release 48 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 49 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 50 50.0 Sq. mm 51 3.5 core 52 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 53 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 54 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 55 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 56 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 57 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 58 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 59 17.2 mm thick and 3 Mtr. Long 60 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 25mm x 3mm Alum. Strip 62 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) 64 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 300 mm sweep(900/1400 RPM) 66 380 mm sweep(900/1400 RPM) 67 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 Up to 380 mm size 69 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 70 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 71 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 72 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 Surface Mounting (with extruded alumn. Housing ) 74 Minimum lumen output 2400 lm 75 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 LED Street Light fixture with Minimum lumen output 8700 lm 77 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 32 mm Dia. 79 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 Cat 6, Un-sheilded Information Outlet 82 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Single Aperture 84 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 86 2 Mtr 87 Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic,should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 12 Ports 90 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.5 TR ISEER not less then 3.8 93 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kVA 95 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 96 100 mm dia per running inch length 97 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 20 mm 99 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 101 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
32.
Housing Urban and Rular Development #10181924 Price Bid
Development Of It And Allied Infrastructure For Temporary Vulnerable Witness Deposition Centre ( Vwdc ) Of The Sub-Divisional Court At Nabadwip, Nadia [ Job No: Kit / Ow / 231 Of 23-24 ] - 1 Sitc Of Layer 2, 24 Port, Poe Enabled, 370 Watt, Full Managed Only, 1Ru, Ge Switch, With Perpetual License Of Oem, Having Minimum Technical Specificationa ) 24 X 10 / 100 / 1000Base-T Mbps Poe+ Enabled Host Ports ( Minimum ) ; B ) 4 X 1 / 10Ge Sfp+Port; And 2 X 10 / 100 / 1000 Base-T Additional Other Than Above Ports; C ) The Switch Should Have 168 Gbps Of Switching Capacity And 125 Mpps Throughput Capacityas Per Details Specification Document Uploaded Separatelyref. Make: Zyxel, Cisco, Juniper, Extreme, Huawei, Aruba, Warranty: 01 ( One ) Years Onsite Comprehensive Oem Warranty Including With Perpetual License, Parts, And Service Except Force Majeure. 2 Sitc Of Ip 2Mp Ir Dome Camera Complete With Perpetual License With Motorized Varifocal Lens Having Minimum Technical Specificationimage Sensor: 1 / 2.8” Progressive Scan Cmos; Min. Illumination: Color: 0.002 Lux @ ( F1.2-1.7, Agc On ) , 0.0002 Lux @ ( F1.2-1.7, Agc On ) , 0 Lux With Ir; Shutter Speed: 1 / 3 S To 1 / 100, 000 S; Focal Length: 2.7 To 13.5 Mm; Aperture: F1.2 To F1.7 With Auto Focus; Lens Mount: Ø14; Ir Range: 40 M Or Higher; As Per Details Specification Document Uploaded Separatelyref. Make: Honeywell, Infinova, Hanwha, Idis, Hikvision, Warranty: 01 ( One ) Years Onsite Comprehensive Oem Warranty Including With Perpetual License, Parts, And Service Except Force Majeure. 3 Sitc Of 16 Channel Fully Featured Ip 4K Network Video Recorder Having Minimum Technical Specificationvideo Input: 16 Channel Ip Fully Featured Nvr; Audio Iuput / Output: 1 Channel Input / 2 Channel Outputs, Rca; Display Interface: 2 Hdmi ( 1 Hdmi Up To 3840 × 2160 ) ; 2 Vga; Record Bit Rate: 320Mbps; Bit Rate: 16 Kbps ~ 20 Mbps, Per Channel; Network Throughput: Input 320Mbps; Output 256Mbps;As Per Details Specification Document Uploaded Separatelyref. Make: Honeywell, Infinova, Hanwha, Idis, Hikvision, Warranty: 01 ( One ) Years Onsite Comprehensive Oem Warranty Including With Perpetual License, Parts, And Service Except Force Majeure. 4 Sitc Of Surveillance Grade Hdd 8Tb Storage Capacity Having Minimum Technical Specificationas Per Details Specification Document Uploaded Separatelyref. Make: Seagate, Western Digital, Sony, Hitachi, Warranty: 01 ( One ) Years Onsite Comprehensive Oem Warranty Including With Perpetual License, Parts, And Service Except Force Majeure. 5 Sitc Of 1 X 03 Kva Rack Mount Online Ups ( 1-Ph To 1-Ph ) System With 1 X 4680 Vah ( Min ) Back-Up Battery And Other Accessories Having Minimum Technical Specificationas Per Details Specification Document Uploaded Separatelyref. Make ( Ups ) : Schneider, Apc, Delta, Vertiv, Avo, Orion, Hitachi, Eaton;Ref. Make ( Battery ) : Amararaja-Quanta, Exide, Warranty: 01 ( One ) Years Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 6 Sitc Of 1 X 01 Kva Rack Mount Online Ups ( 1-Ph To 1-Ph ) System With Inbuilt 1 X 168 Vah ( Min ) Back-Up Battery And Other Accessories Having Minimum Technical Specificationas Per Details Specification Document Uploaded Separatelyref. Make ( Ups ) : Schneider, Apc, Delta, Vertiv, Avo, Orion, Hitachi, Eaton;Ref. Make ( Battery ) : Amararaja-Quanta, Exide, Warranty: 01 ( One ) Years Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 7 Sitc Of Ups Sub-Db 250V, 16Way Spn Mcbdb Having Minimum Technical Specificationas Per Details Specification Document Uploaded Separatelyref. Make: Schneider, Legrand, Hager, Siemens, L&T, Abb, Havellswarranty: 01 ( One ) Years Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 8 Sitc Of Wall Mount Speaker Having Minimum Technical Specificationtype: 2-Way, Bass Reflex Wall Speakers; Frequency Range ( -10Db ) : 62Hz - 20Khz; Nominal Coverage: H ( 120 ) X V ( 120 ) ; Components: 5.25 Cone & 0.75 Soft Dome; Power Rating: 150W; Nominal Impedance: 8O; Tap: 30W ( 330O ) , 15W ( 670O ) , 7.5W ( 1.3Ko ) ; Max Spl: 114Db Spl;As Per Details Specification Document Uploaded Separatelyref. Make: Bosch, Sennheiser, Yamaha, Jbl ( Harman ) , L-Acoustics, Electro Voice, Warranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 9 Sitc Of 2 Channel Power Amplifier Having Minimum Technical Specificationclass D, Two ( 2 ) Channel Power Amplifier With Output Power @ 1Khz ( Thd+N=1%: 4O ) 120W X 2;As Per Details Specification Document Uploaded Separatelyref. Make: Yamaha, Sonodyne, Qsc, Crown ( Harman ) , L-Acoustics, D&B, Warranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 10 Sitc Of Analog Mixer, 24-Channel Mixing Console Having Minimum Technical Specification24 Line Inputs ( 16 Mono, 4 Stereo ) , 16 Mic Inputs With 48V Phantom Power And Hph Per Channel.As Per Details Specification Document Uploaded Separatelyref. Make: Yamaha, Sonodyne, Qsc, Crown ( Harman ) , L-Acoustics, D&B, Warranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 11 Sitc Of Wired Gooseneck Microphone Having Minimum Technical Specificationsupply Of Pre-Polarized Condenser Gooseneck Microphone With Overall Length Of 450Mm Or Better, With Xlr3m-Type Connector, Shall Offer Radio Frequency Interference ( Rfi ) Shielding Against Intermodulation From Wireless Equipment Or Devices.As Per Details Specification Document Uploaded Separatelyref. Make: Sennheiser, Shure, Akg, Rode, Clock Audio, Audix, Bosch, Dpa Microphones, Studiomaster, Warranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 12 .Sitc Of Base For Gooseneck Microphone Having Minimum Technical Specificationbi-Colored Light Ring For Clear Visual Feedback; Logical Function For Easy Control Of E.G. Cameras; Microphone Modes: Toggle On / Off; Push To Mute; Push To Talk; Permanent On ( External Led Control ) .As Per Details Specification Document Uploaded Separatelyref. Make: Sennheiser, Shure, Akg, Rode, Clock Audio, Audix, Bosch, Dpa Microphones, Studiomaster, Warranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 13 Sitc Of 55-Inch Non-Touch Commercial Led Uhd Display ( Indoor Type ) Having Minimum Technical Specificationdiagonal Size: 55 Inch; Panel Technology: Ips; Resolution: 3840 * 2160 Pixels @ 50 Hz; Brightness: 440 Nits; Static Contrast Ratio: 1200:1; Operational Hour: 24 X 7;As Per Details Specification Document Uploaded Separatelyref. Make: Sony, Panasonic, Delta, Nec, Sharp, Lg, Warranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 14 Sitc Of 32-Inch Non-Touch Commercial Led Hd Display ( Indoor Type ) Having Minimum Technical Specificationdiagonal Size: 32 Inch; Panel Technology: Ips; Resolution: 1333 * 768 Pixels @ 50 Hz; Brightness: 350 Nits; Static Contrast Ratio: 1100:1; Operational Hour: 16 X 7;As Per Details Specification Document Uploaded Separatelyref. Make: Sony, Panasonic, Delta, Nec, Sharp, Lg, Warranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 15 Sitc Of 12X Fhd Ptz Camera For Student Having Minimum Technical Specificationfull Hd Ptz Camera Supporting 1080P At 60 Frames Per Second, Minimum 12X Optical Zoom Withfov Of 72 Degree And Minimum 255 Presets. Camera Should Support Simultaneous Outputs Through Ip, Hdmi, Usb 3.0 & 3G-Sdi Output And Can Be Controlled Via Rs232 / 422 And Ip Controls. As Per Details Specification Document Uploaded Separatelyref. Make: Panasonic, Lumens, Peoplelink, Polycom, Avaya, Globus, Wolfvision, Warranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 16 Sitc Of Document Camera Having Minimum Technical Specificationfull Hd Portable Document Camera, 12X Optical Zoom, 10X Digital Zoom, Hdmi In, Hdmi Output, Inbuilt Storageas Per Details Specification Document Uploaded Separatelyref. Make: Lumens, Epson, Elmo, Wolfvision, Samsung, Canon, Peoplelinkwarranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 17 Sitc Of Stereo Professional Headphones Having Minimum Technical Specificationover-Ear, Headphone. Headphone Type: Dynamic, Closed; Magnet Type: Neodymium; Driver Size: 40.0 Mm; Frequency Response: 10-20Khz; Impedance: 63 Ohms; Sensitivity: 106 Db / W / M;As Per Details Specification Document Uploaded Separatelyref. Make: Sony, Sennheiser, Bose, Panasonic, Yamaha, Jbl, Logitechwarranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 18 Sitc Of Hd Audio-Video Live Production Switcher Having Minimum Technical Specificationconnections: Total Video Inputs: 20; Total Video Outputs: 12; Sdi Rates: 1.5G, 3G; Total Audio Inputs: 2 X Balanced 1 / 4 Inch Jack, 1 X 5 Pin Xlr Talkback.; Total Audio Outputs: 1 X 5 Pin Xlr Talkback.; Sdi Audio Inputs: 2 Ch Embedded Audio On All Sdi Inputs.; Sdi Audio Outputs: 2 Ch Embedded Audio On All Sdi Outputs.; Total Multi Views: 2 X 3G-Sdi; Control Panel Connection: Ethernet. Direct Connection Between Panel And Chassis, Or Via Network.; Ethernet: Supports 10 / 100 / 1000 Base-T.As Per Details Specification Document Uploaded Separatelyref. Make: Beyerdynamic Design, Aten, Extron, Lightware, Kramer, Crestron, Canare, Cypress, Seada, Aja, Warranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 19 Sitc Of Audio-Video Recording System For Recording And Streaming Having Minimum Technical Specification:Sdi Video Inputs - 1, Sdi Video Outputs - 2, Sdi Monitor Outputs - 1, Sdi Rates - 270Mb, 1.5G, 3G, 6G Hdmi 2.0 Video Inputs - 1, Hdmi 2.0 Video Outputs - 1, Built In Speaker - Mono, Audio Output - 1 X 6.35 Mm Headphone Jack, Sdi Audio Inputs - 16 Channels Embedded Audio, Sdi Audio Outputs - 16 Channels Embedded Audio, Hdmi Audio Inputs - 8 Channels Embedded Audio, Hdmi Audio Outputs - 8 Channels Embedded Audio, As Per Details Specification Document Uploaded Separatelyref. Make: Beyerdynamic Design, Aten, Extron, Lightware, Kramer, Crestron, Canare, Cypress, Seada, Aja, Warranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 20 Sitc Of Live Video Streaming System Having Minimum Technical Specification:Hdmi / Vga To Hdmi Live Video Streaming And Recording System For Recording And Streaming Live Sessions, Support Upto 4K Uhd+ Resolutions, Built-In Audio Embedding And Mixing Support, Compatible With Facebook, You Tube Or Any Third-Party Cloud, Control Via Front Panel Buttons, Webgui, Telnet, Rs-232 And Ir.As Per Details Specification Document Uploaded Separatelyref. Make: Beyerdynamic Design, Aten, Extron, Lightware, Kramer, Crestron, Canare, Cypress, Seada, Aja, Warranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 21 Sitc Of Intel Core I3 Desktop Computer Having Minimum Technical Specificationdesktop With Intel Core I3-12100 With Intel Uhd Graphics 730, 8Gb Ddr4 Ram, 512Gd M.2 Ssd, 21.5 Display, Integrated Gigabit 10 / 100 / 1000, Dual Band Wi-Fi 802.11 A / B / G / N / Ac & Bluetooth 5.0 Combo, Windows 11 Pro 64Bit Preloaded With Quick Heal Total Security Single User For 01 ( One ) Year.As Per Details Specification Document Uploaded Separatelyref. Make: Hp, Dellwarranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 22 Sitc Of 1Tb Internal Ssd Hard Disc Drive Having Minimum Technical Specificationform Factor: 2.5-Inch ( 7Mm ) ; Capacity: 1Tb; Interface: Sata ( 6Gb / S ) ;As Per Details Specification Document Uploaded Separatelyref. Make: Samsung, Dell, Hp, Wd, Sony, Crucial, Transcend, Seagatewarranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 23 Sitc Of 4Tb Portable Hard Disc Drive Having Minimum Technical Specificationform Factor: 2.5 Inch; Capacity: 4Tb; Interface: Sata ( 6Gb / S ) ; Interface: Usb 3.2 Gen 1, Usb 3.0, Usb 2.0; Transfer Speed: Sequential Read: Up To 540Mb / Sec;Sequential Write: Up To 500 Mb / Sec; As Per Details Specification Document Uploaded Separatelyref. Make: Samsung, Dell, Hp, Wd, Sony, Crucial, Transcend, Seagatewarranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 24 Sitc Of Micro Bi-Directional Sdi / Hdmi 3G Converter Having Minimum Technical Specificationsdi Video Inputs - 1 X Sd, Hd Or 3G-Sdi, Sdi Video Outputs - Automatically Matches The Hdmi Video Input, Hdmi Video Inputs - Hdmi Type A In, Hdmi Outputs - Hdmi Type A Out, Multi Rate Support - Auto Detection Of Sd Or Hd, Updates, Configurations And Power - Usb Type-C.As Per Details Specification Document Uploaded Separatelyref. Make: Beyerdynamic Design, Aten, Extron, Lightware, Kramer, Crestron, Canare, Cypress, Seada, Aja, Warranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 25 Sitc Of Mini Up-Down-Cross Hd Sdi / Hdmi 3G Converter Having Minimum Technical Specificationsdi Video Inputs - 1 X Sd, Hd Or 3G-Sdi Video Input And 1 X External Reference Input, Hdmi Video Input - 1 X Hdmi Type A Connector, Sdi Video Outputs - 1 X Loop Out And 2 X Outputs, Hdmi Video Output - Hdmi Type A Out. Output Supports Edid Of The Monitor, Sdi Rates - 270Mb, 1.5G, 3G.As Per Details Specification Document Uploaded Separatelyref. Make: Beyerdynamic Design, Aten, Extron, Lightware, Kramer, Crestron, Canare, Cypress, Seada, Aja, Warranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 26 Sitc Of 1-In To 2-Out Hdmi Splitter Having Minimum Technical Specificationit Should Connects One Hdmi Source To Two Hdmi Displays At The Same Time; It Should Support Hdmi ( 3D, Deep Color, 4Kx2k ) ; Hdcp 1.4 Compliant; It Should Support Max. Resolution Up To 4096 X 2160 / 3840 X 2160 @ 60Hz ( 2:2:0 ) 4096 X 2160 / 3840 X 2160 @ 30Hz ( 2:2:2 ) .As Per Details Specification Document Uploaded Separatelyref. Make: Beyerdynamic Design, Aten, Extron, Lightware, Kramer, Crestron, Canare, Cypress, Seada, Aja, Warranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 27 Sitc Of 8-Channel High-Power Headphones Mixing And Distribution Amplifier Having Minimum Technical Specificationas Per Details Specification Document Uploaded Separatelyref. Make: Behringer, Beyerdynamic Design, Aten, Extron, Lightware, Kramer, Crestron, Canare, Cypress, Seada, Aja, Warranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 28 Sitc Of Microsoft 365 With Soft Vc License Having Minimum Technical Specificationdescription: Teams; Outlook; Word; Excel; Power Point; Publisher ( Pc Only ) ; Access ( Pc Only ) ; Exchange; Onedrive; Sharepoint;License Duration: 01 ( One ) Years, License User: 1 User.Make: Microsoft 365 Business Standardas Per Details Specification Document Uploaded Separatelyref. Make: Microsoft Warranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 29 Sitc Of Networking Horizontal Un-Armoured Cat6 Cable Having Minimum Technical Specificationas Per Details Specification Document Uploaded Separatelyref. Make: Molex, 3C3, Legrand, Commscope, Belden, Derwiserwarranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 30 Sitc Of Indoor Information Outlet With Rj45 Adapter, Gi Box And Single Face Cover Plate Etc Having Minimum Technical Specificationas Per Details Specification Document Uploaded Separatelyref. Make: Molex, 3C3, Legrand, Commscope, Belden, Derwiserwarranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 31 Sitc Of 1Mtr Cat6 U / Utp Patch Chord Cable Having Minimum Technical Specificationas Per Details Specification Document Uploaded Separatelyref. Make: Molex, 3C3, Legrand, Commscope, Belden, Derwiserwarranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 32 Sitc Of 2Mtr Cat6 U / Utp Patch Chord Cable Having Minimum Technical Specificationas Per Details Specification Document Uploaded Separatelyref. Make: Molex, 3C3, Legrand, Commscope, Belden, Derwiserwarranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 33 Sitc Of Cat 6 U / Utp 24 Port Modular Fully Loaded Patch Panel Having Minimum Technical Specificationas Per Details Specification Document Uploaded Separatelyref. Make: Molex, 3C3, Legrand, Commscope, Belden, Derwiserwarranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 34 Sitc Of 12U Wall Mounted Cross Connect Equipment Network Rack Having Minimum Technical Specificationas Per Details Specification Document Uploaded Separatelyref. Make: Tata, Vertiv, Netrack, Valrack, Rittal, Apw, Mrswarranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 35 Sitc Of 27 / 32U Floor Mounted Cross Connect Audio Video Equipment Rack Having Minimum Technical Specificationas Per Details Specification Document Uploaded Separatelyref. Make: Tata, Vertiv, Netrack, Valrack, Rittal, Apw, Mrswarranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 36 Sitc & Laying Of Pvc Conduits ( Isi Marked ) Laying Through Surface With All Accessories As Required For The Entire System With All Oem Accessories. ( Quality: Mms; Ø=25Mm ) As Per Details Specification Document Uploaded Separatelymake: Precision, Presto Plast, Supreme, Quality : Isiwarranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 37 Sitc Of Single-Phase Ups Power Point To Network Racks At Different Location Having Minimum Technical Specificationas Per Details Specification Document Uploaded Separatelyref. Make: Schneider, Legrand, Hager, Siemens, L&T, Abb, Havellsref. Make ( Wire ) : Polycab, Mescab, Finolex, Havells, Warranty: 01 ( One ) Year Onsite Comprehensive Oem Warranty Including Parts, And Service Except Force Majeure. 38 Sitc Of: Ultra Flexible Premium Sdi / Vga / Hdmi Cable, Cat6 / Data Cable, Power Cable, Unarmoured Audio-Video, Speaker Cable, Xlr Connector Male-Female, Extension Cable, Control Panel, Architectural Adapter Plate, Headphone Db Splitter And Accessories, Audio Patch Panel With All Accessories, 24 / 20 Channel Analog Mixer Stand / Table / Self With Necessary Accessories, Pvc Conduits, Connectors & All Interconnects, And All Other Passive Accessories Will Required To Complete The Work, Etc:Quantity For Above Mentioned All Items: As Per Site Requirement.As Per Details Specification Document Uploaded Separatelyref. Make ( Architectural Adapter Plate ) : Elite Electric, Akamgo, Milan, Blackdote, Mx, Equivalent Logic, Rgblink, Equivalentref. Make ( Headphone Db Splitter ) : Elite Electric, Akamgo, Milan, Blackdote, Mx, Equivalent Logic, Rgblink, Equivalentref. Make ( Audio Patch Panel ) : Elite Electric, Akamgo, Milan, Blackdote, Mx, Equivalent Logic, Rgblink, Equivalentref. Make ( Audio, Speaker Cable ) : Extron, Lightware, Crestron, Canare, Belden, Sommer.Ref. Make ( Hdmi, Vga Cable ) : Extron, Lightware, Crestron, Canare, Belden, Sommer, Aten.Ref. Make ( Connectors, Etc ) : Swisscraft, Neutrik, Amphenol, Canare.Ref. Make ( Power, Cable ) : Polycab, Finolex, Eurocable, Belden, Havells, Ref. Make ( Pvc Conduits ) : Precision, Presto Plast, Supreme, Warranty: 01 ( One ) Years Onsite Comprehensive Oem Warranty With Parts And Service Except Force Majeure.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
West Bengal View Result →
33.
Educational and Research Institute #10115164 Price Bid
Design, Supply, Installation And Commissioning Of A Cleanroom , A ) Cleanroom Construction 1.0 ) Wall Paneling And Ceiling A ) Progressive Type Double Skin Modular 100 Mm Thick Solid Wall Panel Made Of 0.8 Mm Thick Powder Coated Sheets On Both Sides With Puf As Infill Of Density 40 ± 2 Kg / M3, Gi Profiles For Reinforcement Along The Periphery With Bottom Track, And Necessary Arrangements, All Joints Shall Be Sealed With Cleanroom Compatible Neutral Grade Silicon Sealant. All The Cut-Outs Should Be Covered With Suitable Channels. , B ) Progressive Type Double Skin Modular 100 Mm Thick Wall Panel With Inbuilt Riser For Return Air Made Of 0.8 Mm Thick Powder Coated Sheets On Both Sides With Puf As Infill Of Density 40 ± 2 Kg / M3, Gi Profiles For Reinforcement Along The Periphery With Bottom Track, And Necessary Arrangements, All Joints Shall Be Sealed With Cleanroom Compatible Neutral Grade Silicon Sealant. All The Cut-Outs Should Be Covered With Suitable Channels. , C ) Ceiling Wall Panels I ) Grid Type Ceiling System For Class 100The Cleanroom Ceiling Shall Be Formed From A Heavy Duty Aluminium Walkable Extruded T-Grid Ceiling Systems For All Areas. Ceiling Grid Colour Should Match Wall Panel Colour ( Designer White Shade ) . The Ceiling Grid Shall Be Heavy Duty Walkable Inverted T-Grid Ceiling System Of Approx.. 50 Mm Twidth ( Gasket Type Ceiling ) To Be Provided On 600Mm X 1200Mm Hanging Configuration, The System Shall Include Aluminum ( Approx. 50 Mm Wide ) Extrusions, Aluminum Extruded Cross Connector With Hammer Head Bolts And Nuts, M8 Bolt And Matching Square Hanger And Other Standard Accessories. The Grid Should Be Suspended From The Parent Building Roof With Adequate Size Fasteners Etc. For Ensuring Structural Stability Of The Ceiling. Blank Ceiling Panels:50Mm Thick Heavy Duty Walkable Al. Honeycomb Ceiling Blank Panel Of Dimension 1200 Mm X 600Mm X 45 Mm / 50 Mm Thick, Using 45 / 50Mm Thick Aluminum Honeycomb Core Laminated With 0.8 Mm Thick Aluminum Skin On Both Sides, Static Dissipative Finished Of Designer White Shade All Complete. , Ii ) Progressive Type Ceiling For Class 1000 Progressive Type Double Skin Modular 75 Mm Thick Ceiling Wall Panel Made Of 0.8 Mm Thick Powder Coated Sheets On Both Sides With Puf As Infill Of Density 40 ± 2 Kg / M3, Gi Profiles For Reinforcement Along The Periphery With Bottom Aluminium Track, And Necessary Arrangements, All Joints Shall Be Sealed With Cleanroom Compatible Neutral Grade Silicon Sealant. All The Cut-Outs Should Be Covered With Suitable Channels. , D ) Coving: Coving Radius 50 Mm, Moc: Aluminiumcoving Shall Be Installed At :1 ) Wall To Wall 2 ) Wall To Ceiling 3 ) Wall To Flooring , E ) Coving 3D Inner Corner Pieces , F ) Outer Coving , G ) 2D Outer Coving Corner Pieces , H ) Wall Panel Cutouts : All The Necessary Cutouts Made On Wall Panels And Ceiling Will Be Flashed With Gi / Ms Powder Coated C-Channels , I ) Suspended Ceiling Support And Wall Panel Accessories : All The Suspended Ceiling Panels Will Be Supported With 10 / 8 Mm Threaded Rod And Turnbuckle For Easy Level Adjustment At Suitable Locations. Ancillaries Like C-Channel, L-Angles, Required For The Installation Ofm2 Wall & Ceiling Panels , J ) Window Modules Viewing Panels Shall Be Of Double Glazed 5Mm Thick Clear Toughened Glass, Finished With 20Mm Wide Ceramic Borderdimensions: 900X900 In Mm , K ) Cleanroom Doors: The Cleanroom Wall Systems Shall Include All Doors Complete With All Associated Hardware. The Cleanroomdoors Shall Be Of Gi / Ms Powder Coated Construction Of Approximate Size , Flush Configuration, Swing Type, Double Skin. Door Frame Powder Coat Color Must Match With Clean Room Wall System, With Door Closer, Handles, Lock Sets With Option Of One Or Both Side Access, View Glaze Shall Be Of Double Glazed 6Mm Clear Toughened. I ) Cleanroom Single Door-900X2100 In Mm , Ii ) Cleanroom Singleemergency Door-900X2100 In Mm , Iii ) Cleanroom Double Door -1400X2100 In Mm , L ) Fan Filter Modules And Hoodedhepa Filter Modules I ) Hooded Hepa Filter Modules For Class 1000 Hepa Filter Modules: The Cleanroom Ceiling System Shall Include Hepa Filter Ceiling Modules As Indicated On The Drawing. *The Filters Will Be Used As Terminal Air Distribution Device. The Air Supply Plenum Shall Be Connected Directly To A Connecting Collar On The Filter Top With Individual Damper In The Plenum And Flexible Ducts. * The Filters Shall Have H14 Class Filters As Per En1822 With An Efficiency Of 99.95%*The Design Air Velocity Through Filter Shall Be 0.45M / S With Ipd Of 130±5% Pa Or Better.*The Frame Of The Filter Shall Be Of Extruded Anodized Aluminium Construction.*The Filter Media Shall Be Glass Fibre With Hot Melt Separator. *The Filter Shall Have Expanded Sheet Metal Face Guard. The Face Guard Shall Be Powder Coated In Off-White Colour.* The Filter Shall Be Having Endless Polyurethane D-Profile, Liquid Pour To Solid In Extrusion Profile Seal At The Outlet. *All The Filters Shall Be Individually Tested According To En1822 And Computerized Scan Test Report Should Accompany Each Filter.*The Filter Shall Be Held In Place Utilizing ‘Hold Down’ Devices With The Ceiling Grid Using Channel On The Filter Top And T-Bolts In The Ceiling Grid Pressing The Filter Against Ceiling Grid. *All Filter Modules Shall Be Complete With Air Inlet Collar Of 12” Diameter ( Approx. ) . *Top Sheet Should Be Of G.I. / Aluminium Single Piece Drawn With Seamless Neck. In Case, Neck Is Not Seamless, Neck Joint To The Top Sheet Be A Proper Leak Proof Joint And With The Capability Of Supporting A Person Standing On The Top Surface. *Filter Media Shall Be Bonded To Extruded Aluminium Cell Sides.Dimensions :1210 Lx 600 D X 60 Mm Hepa Filter Are Rated 99.97% Efficiency In Removing 0.3? Or Larger Particles. Leak Free In Accordance With Latest I.E.S Recommended Particle.The Filter Media Is Micro Glass Fibre With Poly-String Separator, Sealed To Casing. The Filter Guard Is Provided With Diamond Pattern Expanded Sheet For Protection. , Ii ) Fan Filter Modules With Ulpa Filters For Class 100 : The Fan Filter Units Ffu’S Are Self-Powered Grid Module With Modular Design, To Fitting In Standard T Grid Ceiling. Total Height Is 320Mm. The Fan Filter Module Is U.L Listed And Ce Certified. Ffu Speed Can Vary From 0.2 To .5M / S And Air Flow Rate Vary From 460-760 Cfm. The Sound Level Will Be 55Db’S When Measured From 760Mm Below From Filter Face. The Vibration Level Is 0.9Mils. The Fan Motor Drive Will Be Direct Drive, Forward Curve Centrifugal Type With Sealed Bearing. The Motor Will Have Permanent Split Capacitor Type, Rated For Continuous Operation With Thermal Overload Protection With Two Speed Switch. The Power Requirement Is 230V, 50Hz Single Phase With Maximum Current Of 1.9A With 280Watts Power Input. The Fan / Motor Assembly Is Capable Of Delivering Air At Filter Pressure Of 9Mm To 23Mm Final State. These Ffm Will Have A Speed Controller For Increasing The Speed Of The Motor / Blower From Low, Medium And High. Dimensions :1220 Lx 610 D X 350 Mm H Ffu Material Of Construction : Al Zinc Alloy Hepa Filters Are Rated 99.997% Efficiency In Removing 0.12? Or Larger Particles. Leak Free In Accordance With Latest I.E.S Recommended Particle.The Filter Media Is Micro Glass Fibre With Poly-String Separator, Sealed To Casing. The Filter Guard Is Provided With Diamond Pattern Expanded Sheet For Protection. Dimensions :1210 Lx 600 D X 60 Mm H , M ) Return Air Grille With Collar Damper The Linear Diffusers / Grilles Shall Be Fabricated From Aluminum Extruded Sections. The Diffusion Blades Shall Be Extruded, Flush Mounted Type With Single Or Double Direction Air Flow. The Frame Shall Be Of Aluminum Extruded Section And Shall Hold The Louvers Tightly In Fixed Position. The Dampers As Described Under Grilles Shall Be Provided Wherever Specified. Return Air Grills With Damper At Room Side 800X400. , N ) Antistatic Pvc Flooring I ) The Cleanroom Flooring Shall Be Esd - Pvc 2Mm Thick And The Electro Static Dissipative Will Be Homogeneous Constructed Product Sliced From A Pressed Vinyl Block To Assure A Highly Flexible Tile Of Dense Construction, Dimensionally Stable, Extremely Hard Wearing, With A Completely Non-Directional Pattern. , Ii ) Esd Flooring Includes, Dedicated Earth Pit And Interconnecting Copper Strip 30X5 Mm Thick- 48 Rmt , O ) Cleanroom Lighting I ) Class 100 Cleanroom Lightscleanroom Teardrop Light Fittings For Iso 5 ( Class 100 ) And Surface Mounted Fittings To Be Provided Throughout The Facility To Achieve The 400-450 Lux Lighting Levels. The Teardrop & Surface Mounted Light Fittings Shall Comprise Of A Powder Coated Extruded Aluminum Body And Clear Acrylic Diffusers. Uv Filtration Film Having 350-400 Nm Thickness To Be Applied On Lights Or Uv Tube Sleeves Shall Be Used , Ii ) Class 1000 Cleanroom Lights: Supply And Installation Of Cleanroom Compatible Led Lights. The Envisaged Lighting Level In Clean Rooms Is 500 Lux, At 90 Cm Above The Floor. Lights Must Be Openable Towards Inside The Room. Dimensions: 600X600 Mm Power: 42 W , P ) Air Showersupply Of Ss304 Single Entry Class 10, 000 Airshower 1500 Lx 1500 D X 2300 H In Mm* Dimensions:1500 Lx 1500 D X 2300 H In Mm* Material Of Construction: Ss304 1.6 Mm Thick* Class 100 Compatible* Two Stage Filtration Eu6-Prefilter ( 95% Down To 5 Micron ) For Return Air & Fresh Air Intake* Doors: Ss304, 1, 6 Mm Thick Doors With Double Walled Flush Glass View Panels & Door Closer* Statically & Dynamically Balanced Motor- Blowers With Suspension Arrangement To Reduce Noise Level For Suction And Booster* Differential Pressure Gauge: 1 No. * On / Off Switches* Pao Test Port* Door Interlock Systems – To Ensure That Both The Doors Cannot Open At The Same Time & To Ensure That Both The Doors Will Be Locked During The Time Air Flow Is On.* Timer For Setting Air Shower Operation Time ( Settable For 30 Seconds To 5 Minutes ) * Emergency Stop Button* Straight Entry – Straight Exit / 90° L Type Door Opening * Automatic As Well As Manual Working. , Q ) Static Pass Box Dimensions 600X600x600 In Mmmoc: Ss304 , R ) Sterile Garment Storage Cabinet Supply And Installation Of Ss304, 1.6Mm Thicksterile Garment Storage Cabinet 1200X600x2100 In Mm , B ) Cleanroom Hvac A ) Air Handling Unit I ) Class -100-Ahu- Ahushall Be Of Double Skin, With 45+5 Mm Thick Puf Insulation Sand-Witched Panel, 0.8 Mm Thick Percolated Gss Outer Skin And 0.8 Mm Thick Plain Gi Sheet Inside. The Density Of Puf Insulation Shall Be Minimum 38 Kg / M3.The Casing Shall Incorporate Thermal Break Profile Aluminium And All Other Necessary Design Features To Ensure That Condensate Does Not Occur During All Seasons.Supply Air:4.853 M3 / S, Return Air:4.1 M3 / S , Fresh Air:0.735 M3 / Stotal Fan Static:150 Mm Wg, Cooling Coil Suitable For Chilled Water / Refrigerant Capacity:40 Tr, Heating Coil Capacity:76 Kw , Ii ) Class -1000-Ahu- Ahushall Be Of Double Skin, With 45+5 Mm Thick Puf Insulation Sand-Witched Panel, 0.8 Mm Thick Percolated Gss Outer Skin And 0.8 Mm Thick Plain Gi Sheet Inside. The Density Of Puf Insulation Shall Be Minimum 38 Kg / M3.The Casing Shall Incorporate Thermal Break Profile Aluminium And All Other Necessary Design Features To Ensure That Condensate Does Not Occur During All Seasons. Supply Air:4.382 M3 / S, Return Air:2.733 M3 / S , Fresh Air:1.649 M3 / Stotal Fan Static:150 Mm Wg, Cooling Coil Suitable For Chilled Water / Refrigerant Capacity:40 Tr, Heating Coil Capacity:57 Kw , B ) Chiller Unit ( 2W+1 S ) Supplying, Installing, Testing And Commissioning Of Ahri Certifiedair Cooled Scroll Water Chilling Units Of 40 Tr Capacity ( Actual ) Complete With Twin Screw Design Compressor With Star-Delta, Squirrel Cage Induction Motor, Starter Panel Machine Mounted, Water Cooled Condenser, Insulated Chiller, Flow Switch At Chiller And Condenser, Neoprene Pads, Integral Refrigerant Piping And Wiring, Bms Interface Unit Modbus, Counter Flanges Along With Flanged Connection For Condenser And Cooler Water In / Out Connections, Complete Charge Of Refrigerant And Oil, Accessories As Required And Called For, Automatic And Safety Controls Mounted In Central Micro-Processor Based Console Panel And All Mounted On A Steel Frame Complete As Per Specifications. Motor Shall Be Suitable For 415±10% 50 Cycles. 3Phase Ac Supply And Motor Cable Terminal Box Shall Be Suitable To Connect Copper Cabling. Refrigerant Used Shall Be Ozone Friendly Hfc134a / R410a As Detailed In Specifications. First Chiller Shall Be Factory Tested At Design Conditions At 100%, 75%, 50% And 25% Load. Cooling Capacity: 40 Trwater Flow-900 Lpmlpmsupply Water Temp. In Deg C- 5-7 Deg C Return Water Temp In Deg C-12 Deg C , C ) Chilled Water Pumps For Chillers ( 1 W+1S ) I ) Chilled Water Pumps Horizontal & Centrifugal Type Pumps. Supplying , Installation, Testing And Commissioning Of The Pumps Shall Be Horizontal, Close Coupled , Single Stage , Centrifugal , End Suction With Backpull Out Design. Hence , The Rotating Unit Can Be Removed And Serviced Without Disconnecting The Suction And Discharge Piping. The Pump Shall Be Balanced Statically And Dynamically. The Pump Are At Constant Speed And Suitable For Vfd Drive. The Noise Level Shall Not Exceed 75 Dba At 1M From The Source.The Pumps Shall Be Bms Compatible. Flow Rate:900 Lpm, Total Head: 30 M, Moc: Body : Ci, Impellor: Ss304 , Ii ) Chilled Water Piping With Al. Cladding Insulation: Chilled Water Piping With Al Claddingshall Be Installed For: Ahuand Pumps. Moc Of Pipe Shall Be Sch10 Ss304 With All Accessories , D ) Gi Ducting Supply, Installation, Testing & Commissioning Of Pre-Fabricated Gi Sheet Metal Ducting ( Prefabricating Ducting Means Duct Fabrication On Cnc Machines ) Complete With Gi / Ms Supports ( Complete Supporting Structure To Install Ducts At Site ) With Fully Threaded Gi Rods, Gi Nuts And Bolts ( With Check Nuts Wherever Applicable ) , Vanes, Splitters, Thermal Isolation Blocks, Etc. As Per Drawings And Smacna Standards For 4 Inch And 2 Inch Pressure Class. Ducting Will Have Ductmate Flanges With Food Grade Rubber Gasket Between Theflanges. All Duct Supports Shall Have Minimum 3 Mm Thk. Insulated Tape Between Support And Duct. All Ducting Seam To Be Sealed With Rtv Sealant. The Zinc Coatingthickness Should Not Be Less Than 120 Grams / Sq, Mtr ( Gsm ) .All Duct Joints Shall Be Inspected For Leakage. I ) 24G , Ii ) Ms Supporting System , E ) Insulation Supply, Installation Ofnitrile Rubber Insulation With One Side Aluminum Faced. The Insulation Material Shall Be Fm Approved. The Insulation Shall Have Fire Performance Such That It Passes Class ‘O’ As Per Bs 476 Part 6 For Fire Propagation And Class 1 As Per Bs 476 Part 7 For Surface Spread Of Flame. All Insulation Joints ( Including Flange Joints ) To Be Sealed With 3 Width Self Adhesive Tape. I ) 19Mm Thick Insulation , Ii ) 16Mm Thick Insulation , F ) Dampers Manual Low Leakage Volume Control Damperof Class 4 As Per Bs En 1751 ( Permissible Leakage Allowed -6.2 L / S / Sq M, Test Certificate Required ) And Shall Be Made Out Of 18G Gi, Opposed Type Multi Aerofoil Shape Blade With Handle And Wing Nut, Clearly Marked With Open / Close, Percentage Open, Locking In Position And Sealing Arrangement For Branches. The Dampers Should Be Suitable For Manual & Motorized Operation And Shall Have The Plain & Rigid Base Plate To Install Actuator. Damper Shaft Rod Shall Be Square. I ) Gi Round Damper 250Mm Dia 18 G , Ii ) Flexible Insulated Duct 200 Mm Dia , G ) Flexible Canvas Connection Supply Of 150 Mm Deep Antivibration Flexible Joints Made Out Of Imported Fire Resistance Flexible Double Canvas Sleeve With Extruded Aluminium Frame / Flanges On Both Sides , C ) Cleanroom And Hvac Electrical A ) Hvac Electrical Dbsupply, Installation, Testing And Commissioning Of Floor Mounted Type Vfd Electrical Control Panel And Provision Formicroprocessor Controller With Hmi ( Refer To The I / O Points Mentioned In The Technical Specifications Document Under Section 4.3: Plc Panel With Hmi ) Provision For :Safety Interlock I ) Ahu Blower-Vfd-6 Kw, 3 Ph , Ii ) Chiller Unit-41 Kw, 3 Ph-Contactor , Iii ) Heater- Ssr-60 & 80 Kw 3 Ph , Iv ) Pumps-8 Kw, 3 Ph- Contactor With Star Delta Starter , V ) Exhaust Blower-8 Kw 3 Ph, -Contactor With Star Delta Starter , Vi ) Process Cooling Chiller-8 Kw, 3Phcontactor , Vii ) Compressed Air Plant -8 Kw, 3 Ph Contactor , Viii ) Di Water Plant- 3 Kw , 3 Ph Contactor , Interlocks I ) Flow Switch , Ii ) Ahu Door Interlock , Iii ) Chiller-Pump Interlock , Iv ) Smoke And Fire , V ) Thermal Interlock , Vi ) Access Control Emergency Interlock , B ) Cleanroom Electrical Sub Db - Ups Db And Raw Power Db Supply, Installation, Testing And Commissioning Of Wall Mounted / Floor Mounted Type Distribution Board. Provision At Db: I ) Cleanroom Sub Db - 2 Nos ( 1 Ups, 1 Raw Power ) , Ii ) Cleanroom Lighting ( 40W ) - 1 Ph , Iii ) Cleanroom Power Points ( 5 / 15A ) , Iv ) Fan Filter Units ( 2.5 A ) - 1 Ph , V ) Air Shower ( 1.5Kw ) - 3 Ph , Vi ) Sterile Garment Cabinet ( 6 A ) - 1 Ph , Vii ) Static Pass Box ( 6A ) - 1 Ph , Viii ) Access Control System ( 6A ) -1Ph , Ix ) Cctv - 1Ph , X ) Clear Room Equipments: 3Ph 32 A , Xi ) Cleanroom Power Points:1Ph 5 / 15 A Power Points , C ) Electrical Cabling And Accessories Hvac Cabling: Hvac Cabling Shall Be Laid In Metal Trunking ( Electrical Incoming Power To Hvac Panel, Sub Db Will Be Provided By Iitm ) I ) Cabling For Ahu Blower-6Kw- 2Nos.-4 Mm2, 4 Core Armored Cable , Ii ) Cabling For Ahu Blower Interlock And Emergency Light- 2Nos.- 2.5Mm 2, 3 Core Cable , Iii ) Cabling For Modulating Valve- 2Nos.- 1.5Mm 2 Shielded 3 Core Cable , Iv ) Cabling For Heaters-3 Ph , 60 Kw & 80 Kw 2Nos.6Mm 2, 3 Corearmored Cable , V ) Cabling For Chiller- 41 Kw-3Nos.- 25Mm2, 5 Core Armored Cable , Vi ) Cabling For Pumps- 8 Kw-2 Nos.-4 Mm2, 4 Core Armored Cable , Vii ) Cabling For Process Cooling Chiller- 8 Kw-1 Nos.-4 Mm2, 4 Core Armored Cable , Viii ) Cabling For Compressed Air Plant- 8 Kw-1 Nos.-4 Mm2, 4 Core Armored Cable , Ix ) Cabling For Exhaust Blowers- 8 Kw-2 Nos.-4 Mm2, 4 Core Armored Cable , X ) Cabling For Di Water Plant- 3 Kw-1 Nos.-2.5 Mm2, 4 Core Armored Cable , Xi ) Cabling For - Flow Sensor- 2 Nos.1.5Mm2 Shielded 3 Core Cable , Xii ) Cabling For - Room Temp And Rh- 2 Nos.1.5Mm2 Shielded 3 Core Cable , Xiii ) Cabling For - Thermal Sensor-2 Nos.-1.5Mm2 Shielded 3 Core Cable , D ) Cabling For Cleanroom Equipments Cabling For Cleanroom Equipments Shall Be Layed Through Pvc Dado I ) Cabling For Cleanroom Lights-30 Nos- 2.5Mm 2, 3 Core Cable , Ii ) Cabling For Fan Filter Units-16 Nos.- 1.5Mm 2, 3 Core Cable , Iii ) Cabling For1ph Power Points-30 Nos.-2.5Mm 2, 3 Core Cable , Iv ) Cabling For 3Ph, 32 A, 5 Wire , Power Points - 10 Nos- 4Mm2, 5 Core Cable , V ) Cabling For Air Shower- 1 Nos-2.5Mm 2, 5 Core Cable , Vi ) Cabling For Garment Cubicle- 1 Nos, .- 2.5Mm 2 , 3 Core Cable , Vii ) Cabling For Access Control System-2 Nos.- 1.5Mm 2, 3 Core Cable , Viii ) Cabling For Cctv- 11 Nos-Cat 6 Cable , Ix ) Earthpits , D ) Process Utilities A ) Gas Lines For N2, Ar And O2supply And Installation Ofuhp Gas Lines Double Cylinderauto Changeover Over Panel For N2, Ar & O2 I ) Double Cylinder Auto Changeover Panel For N2- 1 Nos. , Ii ) Single Cylinder Auto Changeover Panel For Ar- 1 Nos. , Iii ) Single Cylinder Auto Changeover Panel For O2- 1 Nos. , Iv ) 1 / 4 Ss316 L Ep Pipes , V ) Tap Off Points With Diaphragm Valve, Regulator And Gauge , Vi ) Supporting System And Clamps , Vii ) Cylinder Mounting Accessories , B ) Compressed Air ( Cda ) System I ) Supply Of Compressor Supply Of Oil Free And Moisture Free Scroll Compressor 9 Cfm Capacity, 10 Bar Pressure Rating , With 150 L Storagetank , Ii ) Supply And Installation Of Compressed Air Line: A ) Moc: Ss316l3 / 4 -50 Rmt , B ) Tap Off Points: Tap Off Points With Isolation Valve And Regulator , C ) Supply & Installation Of Process Cooling Water System I ) System Must Have Working And Stand By Pumps Of 50-60 Lpm At 17-19 Deg C At 4-5 Bar Pressure, Storage Tank Of 400 L, All Ss304interconnecting Pipes And Valves & Control Panel, Moc: Moc Of The System Ss304 , Ii ) Supply & Installation Of Process Cooling Water Distribution A ) Moc Of Distribution Lines: 1 Upvc Sch 80 , B ) No. Of Tap Off Points ( Tap Off Points Should Have Ball Valve, Gauge, Flow Meter, Prv ) , D ) Utility Drain Line I ) Utility Drain Line Shall Be Pp Sch 80 Dn 50Mm , Ii ) Tap Off Points , E ) Polypropylene Wet Chemical Bench Polypropylene Wet Chemical Bench-1800 Wx 950 D X 2300 H Mmmoc: Polypropylene Fire Retardant Utilities:N2, Di Water , Ro Water Connection, Drain, Power Points5 / 15A- 4 Nos, Lights- 2 Nos, Storage Trolley- 2 Nos. , F ) Scrubber And Exhaust Ducting Wet Scrubber I ) Pp+Frp Packed Bed Type Wet Scrubber For 3500 Cfm Capacity , Ii ) Pp+Frp 3+2 Mm Thick Ducting 300Mm Dia. , Iii ) Ppfrp Blower 2500 Cfm Capacity @ 350 Mm Total Static , Iv ) Tap Off Points With Vcd Dia. 200 Mm , G ) Fume Hood For Solvents Moc: Polypropylene Fire Retardant Dimensions: 1200 W X950 D X2300 H In Mmutilities:N2, Di Water , Ro Water Connection, Drain, Power Points5 / 15A- 4 Nos, Uv-Lights- 2 Nos, Storage Trolley- 2 Nos. , H ) Blower And Exhaust Ducting Blower Moc: Ss304 I ) Blower Capacity: 1000 Cfm @ 75 Mm Total Static , Ii ) Duct Moc: Ss304 200Mm Dia With All Accessories-25Rmt , Iii ) Bibo Box For Activated Carbon Filter , I ) Di Water Plant A De-Ionized Water System Consisting Of A Generation And Storage System For Generating And Storing Type-I ( Resistivity = 18 M?-Cm ) And Type-Ii Water ( Resistivity = 1 M?-Cm ) Should Be Provided. In Addition To The Resistivity Metrics, Plant Shall Be Recirculatory Type And Pressure Depended Type. Di / Type I Water Flow Rate:1-2 Lpm@ 1.5-2 Bar Ro / Type Ii Water Flow Rate:2 Lpm @ 1.5-2 Bar , J ) Di Water Pipingdi Water Piping Moc: Pp Pp Dn 25Mm Pipe With All Accessories- 70 Rmttap Off Points- 3 Nos.Tap Off Must Have Isolation Valve- 3 Nos. , E ) Spin Coater Programmable Spin Coater • Bowl-Shaped Process Chamber Which Can Hold Size 6 ( ~150 Mm ) Diameter Wafers Or 5 ( ~125 Mm ) Square Substrates • Ac Brushless Motor Featuring Bi-Directional Rotation / Agitation, High Acceleration, And A Wide Speed Range • Digital Process Controller For Easy Programming • Speed : 1-12, 000 Rpm • Accuracy <+-0.5% Of Full Speed • Time: 1 Second To 99 Minutes 59.9 Seconds In 0.1 Second Increments • Programs: Twenty Multi-Step Programs Or Manual Mode • Real Time Display Of Rpm, Time And Program Stamps • Input And Control Through Soft Touch Keypad • Acceleration: Up To 13K Rpm / Sec With Standard Chuck ( Programmable In 1 Rpm Increments ) • Pc Interface Software To Be Included • Fluid-Control Lid Directs Materials Towards Rear Drain — No Drips Should Be Encountered When Opening Chamber • Chemically-Resistant Lid With Ø3 / 4; ( Ø19 Mm ) Center Opening • Npp Vacuum Chuck For Ø50 Mm Through Ø150 Mm Substrates • Npp Fragment Chuck Adapter — Fits Over Above Chuck For Holding 10 Mm Through ~50 Mm Pieces Ø1.5; ( Ø38 Mm ) Npp Drain Port And Nitrogen Purge • Polypropylene Drain Container To Store Exhausted Drain Reservoir • With Necessary Interlock, Latch And Lock For Safety Of The Door • With Oil-Less Vacuum Pump ( 220 Vac, 50 / 60 Hz ) And Inlet Port , F ) Life Safety And Security System A ) Cctv - Cameras , B ) Access Control System For 1 Door , C ) Door Interlock System For Air Lock Room , D ) Smoke And Fire Detection System , E ) Local Area Network , F ) Telephone , G ) Local Fire Extinguishers : Suitable For A, B, C Fire Classifications 5 Kg Capacity Suitable For Cleanroom Application , G ) Cleanroom Furniture I ) Ss316l Cleanroom Cross Over Bench 2100X400x550mm , Ii ) Ss316l Working Table 1500X900x750mm With 2 Power Points , Iii ) Ss316l Tables With Under Table, Table Dimensions 1200X750x750, Under Tablecubicles 500X700x700, 2 Drawers And 1 Door , Iv ) Class 100 Compatible Cleanroom Chairs , V ) Class 100 Compatible Cleanroom Stools , Vi ) Polypropylene Chemical Storage Cabinet 900 W X550 Dx2100 H In Mm , Vii ) Ss316l Cleanroom Bins-Dia 350X650 H In Mm , H ) Room Differential Pressure Gauges , I ) Temp And Rh Indicator , J ) Engineering, Design And Drawings , K ) Documentation , L ) Commissioning And Validation
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
34.
Educational and Research Institute #10058751 Price Bid
Tender For Supply, Installation, Testing And Commissioning Of Hvac And Electrical Works For Establishment Of Drtb Ward At Aiims Rishikesh; 1 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire 2 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required4 X 10 sq. mm + 2 X 6 sq. mm earth wire 3 Supplying and fixing suitable size GI/PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door 5 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 6 Supplying and fixing following rating, four pole 415-volt TPN MCB in the existing MCB DB complete with connections, testing and commissioning etc. as requiredMCB TPN 63-amp, C Curve 7 Once through Double Deck AHU (OAHU - 100% Fresh air & 100% exhaust with heat recovery unit):- Supply Installation Testing & Commissioning of double Skin Horizontal Air Handling Unit complete with, Bottom Deck:- consisting 100% fresh air intake provisions with aluminum dampers on fresh air side and supply air side, all filters flanged type i.e. pre filters (G-4), fine filter (F-9), with double skin (45±2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. Sandwiched between 0.8 mm thick G.I. pre-coated Sheets for Outer skin and internal skin shall be plain G.I of 0.8 mm thick. All frame work shall be with thermal break profile constructed. The blowers shall be backward curved Centrifugal plug fan (with calibrated nozzle for air flow/DP measurement) with driven motor - IE3 (VFD compatible) with minimum IP55 protection. Cushy foot mountings, Inspection LED lamp, door limit switch, SS insulated condensate drain pan made out of SS-304 and standard accessories. The unit shall be comprising of 8 row deep DX cooing coil made out of copper tubing and copper header. AHU to be mounted on adequate RCC cubes with double vibration pad and GI sheet etc. to be considered in scope. UVGI System: - UVGI system shall be designed to cover the entire face area of the cooling coil to achieve near total elimination of bacteria/ virus / biomass on the cooling coil. Required number of UVGI Lamps in the AHUs for the cooling coil area, along with reflector, ballast, junction box, mounting arrangement complete with connections etc. as required. UVGI system shall be installed downstream of the cooling coil. Cross flow type heat exchanger: - The supply and exhaust airflow perpendicular to each other separated by aluminum plates which transfer the heat from one side to the other. Heat transferred from one air flow to another without mixing the air flows. Sensible Efficiency up to 80%. Upper Deck: - consisting 100% exhaust air provisions with aluminum dampers on exhaust air side and return air side, all filters flanged type i.e. pre-filters (G-4), HEPA filter (H-13) sections with double skin (45±2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. Sandwiched between 0.8 mm thick G.I. pre-coated Sheets for Outer skin and internal skin shall be plain G.I of 0.8mm thick. All frame work shall be with thermal break profile constructed. The blowers shall be backward curved Centrifugal plug fan (with calibrated nozzle for air flow/DP measurement) with driven motor - IE3 (VFD compatible) with minimum IP55 protection. Cushy foot mountings, Inspection LED lamp, door limit switch and standard accessories. Supply Air Fan Capacity, CFM: 2400 Return Air Fan Capacity, CFM: 3000 DX Cooling Coil Load, TR: 16 Total Supply side Static, Pa: 1000 Total Return side Static, Pa: 1000 8 Supply, installation, testing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet 9 Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., as per specifications. 10 Supply, installation, testing and commissioning of air diffusers of powder coated aluminum with aluminum volume control dampers with anti-smudge ring & removable core 11 Supply, installation, testing and commissioning of Fresh / Exhaust air intake louvers made from 3 wide (Minimum 3 MM thickness) powder coated extruded aluminum @ 1 pitch with proper stiffeners complete with HDPE insect mesh fixed in a removable frame as per approved design. 12 Supply, installation, testing and commissioning of fire dampers in supply air duct/main branch and return air duct as and where required of required sizes i/c control panel, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications Fire damper 13 Supply, installation, testing and commissioning of fire dampers in supply air duct/main branch and return air duct as and where required of required sizes i/c control panel, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications Actuator 14 Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class O) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self-adhesive nitrile rubber tape insulation complete as per specifications and as required.19 mm 15 Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class O) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self-adhesive nitrile rubber tape insulation complete as per specifications and as required.25 mm 16 Supply, installation, testing and commissioning of 0.63 mm aluminum sheet cladding as required complete in all respect with fixing screws etc., for cladding of outside / exposed ducts. 17 Supply Installation, Testing & Commissioning of modular type Variable Refrigerant flow /Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A/latest Refrigerant, vibration isolators, outdoor unit frame with suitable foundation, complete with all accessories as required etc. The unit shall deliver the rated capacity at AHRI Conditions and work even at approx. 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 complete as per the technical specifications. Capacity: 20 HP 18 Supply Installation, Testing & Commissioning of AHU Kit consists of a control PCB, electronic expansion valve, complete with all accessories as required etc. This kit will connect the AHU to the VRF Outdoor Unit. 19 Supply Installation, Testing & Commissioning of Corded Thermostat cum controller for temperature setting and operation, complete with all accessories as required etc. (Dual mode: Cooling & Heating). 20 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, complete with all accessories as required etc. 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation 21 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, complete with all accessories as required etc. 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation 22 Supply, Installation, testing and commissioning of 40 mm dia nominal bore B class medium duty G.I. pipe conforming to IS 1239 including welding, fittings likes elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. complete in all respect for AHU condensate drain piping with 19 mm thick nitrile rubber insulation, nut-bolts, supports, pipe support block etc. duly installed with 0.63 mm aluminum sheet cladding as required complete in all respect with fixing screws etc. 23 Supply & Installation of Digital Magnehelic gauge with suitable 24 gauge smoothened to 240 grit SS304 face plates & 16-gauge GI Box & PU Tube/ silicon tubing (Range: 30 - 0 - 30 Pa) suitable to install in modular panel with nozzle & complete accessories for clean rooms. 24 Supply, Installation, Testing & Commissioning of Electric tubular finned Heaters of 12 kW capacity in SS construction and bank wise distribution, duly installed in ducts complete with mounting arrangement, safety thermostat, humidistat for humidity control, SSR based control, contactor etc. Heater should be ISI marked. 25 Fabrication, Supply, Installation, Testing, Commissioning of Outdoor floor mount type AHU control Panel with following specifications: CRC Sheet of 3.15 mm, Grey Color with Incoming: 1 Incomer -200 Ampere MCCB/16KA 4 Pole. Panel must include R, Y, B Indicator, with 250 ampere aluminum busbar, 1No Digital Multi-Function Metre / Digital Load Manager suitable to connect with Centre Energy Monitoring System/BMS through RS485 connection. Outgoing: Outgoing -2 Nos with 25 Ampere MCB/16KA 4 Pole for supply motor - 4 kW, exhaust motor - 4 kW. All outgoings shall be with necessary MCBs, contactors, relays, illuminated push button for manual ON & OFF, indication lamps (for ON, OFF, TRIP Status), Auto/Manual selector switch. Outgoing -1 Nos with 63 Ampere MCCB/16KA 4 Pole for VRF outdoor unit. All outgoings shall be with necessary MCBs, contactors, relays, illuminated push button for manual ON & OFF, indication lamps (for ON, OFF, TRIP Status), Auto/Manual selector switch. Outgoing -1 Nos with 40 Ampere MCCB/16KA 4 Pole for heaters - 12 kW (three bank distribution). All outgoings shall be with necessary MCBs, contactors, relays, illuminated push button for manual ON & OFF, indication lamps ( for ON,OFF,TRIP Status), Auto/Manual selector switch. Outgoings with suitable rating MCBs shall be considered for UVGI system, fire damper, AHU limit switch etc. Necessary safety interlocks like AHU motor interlock with service door limit switch, fire damper interlock, supply & exhaust fan interlock, UVGI system and heaters interlocks with AHU). Potential free Contact (for supply motor, exhaust motor, fire damper, heater, humidifier etc.) to be provided for Connections to BMS. Note:- 1. VFD (for motor speed control) with inbuilt PID controller for varying the speed of fan, along with DPT (0 to 3000 pa) sensor for measuring DP across fan and providing input to VFD. VFD to be installed/mounted in motor control panel. Capacity of VFD: 4 kW - 1 No. (for Supply motor) & 4 kW - 1 No. (for exhaust motor) 2. Provision of MCB / Contactor for UVGI system, AHU limit switch, Fire damper etc. to be considered in AHU control panel. 26 Supply, laying, Testing and Commissioning of following size XLPE insulated armored Cable (Galvanized wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with up to date amendments on surface / cable tray as required and as directed by Engineering in charge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc.armored aluminum cable 3.5 C X 95 sq. mm 27 Supply, laying, Testing and Commissioning of following size XLPE insulated armored Cable (Galvanized wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with up to date amendments on surface / cable tray as required and as directed by Engineering in charge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc.armored copper cable 4 C X 10 sq. mm 28 Supply, laying, Testing and Commissioning of following size XLPE insulated armored Cable (Galvanized wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with up to date amendments on surface / cable tray as required and as directed by Engineering in charge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc.armored copper cable 4 C X 6 sq. mm 29 Supply, laying, Testing and Commissioning of following size XLPE insulated armored Cable (Galvanized wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with up to date amendments on surface / cable tray as required and as directed by Engineering in charge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc.armored copper cable 4 C X 4 sq. mm 30 Supply, laying, Testing and Commissioning of following size XLPE insulated armored Cable (Galvanized wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with up to date amendments on surface / cable tray as required and as directed by Engineering in charge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc.armored copper cable 4 C X 1.5 sq. mm 31 Supply, laying, Testing and Commissioning of following size XLPE insulated armored Cable (Galvanized wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with up to date amendments on surface / cable tray as required and as directed by Engineering in charge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc. armored copper cable 2 C X 1.5 sq. mm 32 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required 150 mm width X 50 mm depth X 1.6 mm thickness 33 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required 100 mm width X 50 mm depth X 1.6 mm thickness 34 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7-metre-long etc. with charcoal/ coke and salt as required.(Set of 2) 35 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 36 Supply and installation of 3 mm thick Aluminum composite panel sheet with necessary support for installation by using screws and silicon sealants in all joints with complete accessories as required etc. for closing the gaps between ducts and civil wall / closing the gap between false ceiling and civil wall.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttarakhand View Result →
35.
Public Administrative Department #10027101 Technical Bid
Tender for Item-Wise Rates Of Various Non-Schedule Items For Different Development Works / Renovation Of Conference Hall Of Paradeep Municipality. , Supply, Installation, Testing And Commissioning Of Electric High Speed Light Weight 50W 400 Mm Wall Fan Of White Colour Is A Space-Saving And Efficient Cooling Solution Designed For Optimal Air Circulation In Both Residential And Commercial Settings. Mounted On A Wall, These Fans Offer A Directed And Localized Breeze, Making Them Ideal For Spaces Where Floor Space Is Limited Or Where A Targeted Airflow Is Desired. Specification: Dimensions - 49.2D X 77.8W X 46.9H Centimeters, Noise Level-63 Db, Glossy Finish, Number Of Blades-01, Air Flow Capacity- 72 Cubic Meters Per Minute, Blade Length-400 Millimeters, Speed- 1.36E+3 Rpm, 230 Volts, Remote Type, Specification Met- Ce. Make- Havells/ Cg/ Bajaj , Supply, Installation, Testing And Commissioning Of Electric Single Phase Exhaust Fan 12Inch. Specification: 300Mm Exhaust Fan | Strong Air Suction, Rust Proof Body |Suitable For Bathroom, Kitchen, And Office. Product Dimensions 42D X 42W X 21.5H Cm, Special Feature Portable, Water Resistant, Waterproof. Make- Havells/ Cg/ Bajaj , Supply And Installation, Testing & Commissioning Of 5Kva (1Ph-1Ph) Online Double Conversion Ups Having 1Ph-1Ph With Inbuilt Isolation Transformer, With Ms Rack Rack , Dc Cable, Links With Two Years Warranty. With Back Up Of 60 Minutes. Make : Numeric - Legrand/ Delta/ Vertive Battery: For 60 Minutes Battery Back , Ms Rack, Linkd Dc Cable And Battery 12V/42Ah/16Nos.. Minimum Vah Reqd. 10080 Vah. Make-Exide Quanta / V-Guard/ Luminous , Water Purifier: Supply Of Ro Water Purifier 5 Stage Filtration, 50-55 Ltr/Hr. Capacity. Make- Lexpure/ Kent/ Livpure , Water Purifier:T Echnician Charges Towards Fitting, Fixing, Installation And Commissioning Of Ro Water Purifier 5 Stage Filtration, 50-55 Ltr/Hr. Capacity With Supply Of Clamp, Screw, Nut Bolt And Etc. As Per Requirement And Direction Of Engineer-In-Charge.Make- Lexpure/ Kent/ Livpure , Water Cooler : Supply Of 150 Ltr. Water Dispenser Is A Premium Product Suitable For Residential And Commercial Settings. Its Modern And Elegant Design Makes It A Versatile Addition To Any Space. Equipped With A 1/2 Bsp Thread Connection Type, This Dispenser Guarantees A Secure And Leak-Proof Installation. Boasting A Cooling Capacity Of 150 L/Hr, It Ensures A Constant Supply Of Cold Water. Crafted From High-Quality Stainless Steel, The Body Of This Dispenser Is Durable And Long-Lasting, Resistant To Corrosion, Rust, And Stains. Its Hot And Cold Modes Provide The Convenience Of Instant Access To Both Temperatures Of Water. 02 Nos.. Of Taps, 9.5 Rated Current, Stainless Steel Body. Item Depth (Mm)-589, Item Height (Mm)-1235, Item Weight (Kg)-64, Cooling Capacity (L/Hr)-150, Hot/Warm Water Dispensing Capacity-Na, Hot/Warm Water Dispensing Capacity Unit-Na, Cooling Storage Capacity (L)-150,Cooling Storage Capacity Unit-Liters, Normal Storage Capacity-Na, Normal Storage Capacity Unit-Na, Hot/Warm Water Storage Capacity-2, Hot/Warm Water Storage Capacity Unit-L, Package Width (Mm)-911, Package Depth (Mm)-690, Package Height (Mm)-1247, Package Weight (Kg)-74, Product Warranty-1 Year, Power Rating-Cooling (In Watts) 2100 @35C, Minimum Input Voltage Range 220 (Volts), Maximum Input Voltage Range-240 (Volts), Input Voltage Frequency (Hz)-50, Input Plug / Connector Type-3 Pin Plug , 16 Amp, Cord Length (Meters)-1.5, Function Cold | Warm, Refrigerant-R32, Usp Feature 1 Warm And Cold Dispensing Option, Usp Feature 2 Sturdy Compressor And Trouble Free Operation, Usp Feature 3 Eco- Friendly, Usp Feature 4 Silent Operation, Usp Feature 5 Food Grade Ss304 Tank. Make- Blue Star/ Kent/Usha , Water Cooler : Technician Charges Towards Fitting, Fixing, Installation And Commissioning Of 150 Ltr. Water Dispenser With Supply Of All Clamps , Screws, Nut Bolts And Etc. As Per Requirement And Direction Of Engineer-In-Charge. , Fire Extinguisher : Providing ,Fixing , Testing And Commissioning Of Carbon Dioxide (Co2) Type Fire Extinguisher, Isi Mark, Cap-4.5 Kg. Make - Safepro/Fire Shield , Fire Extinguisher : Providing ,Fixing , Testing And Commissioning Of Abc Type Fire Extinguisher, Isi Mark, Cap-6.0 Kg. Make - Safepro/Fire Shield , Fire Extinguisher : Providing ,Fixing , Testing And Commissioning Of Foam Type Fire Extinguisher, Isi Mark, Cap-9 Ltr. Make - Safepro/Fire Shield , Audio Visual Work : Supply Of Chairman Unit Long Unit- Digital With Chairman Button: Frequency Response:200 Hz To 12.5 Khz Headphones Load Impedance: 32 Ohms 1K Ohm Loudspeaker Nominal Output:72 Db special Length Of Microphone From Mounting Surface:480 Mm (18.9 In) Operating Temperature:0 ºc To +35 ºc Plug And Play Functionality For Ensuring Fast Installation And Reconfiguration Times Immunity To Mobile Phone Interference Functions Possible-To-Speak Indication Built-In Loudspeaker With Volume Control Headphones Socket: Built- In 3.5 Mm (0.14 In) Stereo Headphones Built-In Volume Control For Headphones Color-Coded Led Indicator Above Microphone Button For Showing The Following States: Microphone On, Request-To-Speak, And Possible-To-Speak Similar To Make Bosch Model No. Ccsd- Dl+Chairma N Button Complete. , Audio Visual Work : Supply Of Delegate Unit Long Unit- Digital Frequency Response:200 Hz To 12.5 Khz Headphones Load Impedance: 32 Ohms 1K Ohm Loudspeaker Nominal Output:72 Db special Length Of Microphone From Mounting Surface:480 Mm (18.9 In) Operating Temperature:0 ºc To +35 ºc Plug And Play Functionality For Ensuring Fast Installation And Reconfiguration Times Immunity To Mobile Phone Interference Functions: Possible-To-Speak Indication Request-To-Speak Indication Built-In Loudspeaker With Volume Control Headphones Socket: Built- In 3.5 Mm (0.14 In) Stereo Headphones Built-In Volume Control For Headphones Color-Coded Led Indicator Above Microphone Button For Showing The Following States: Microphone On, Request-To-Speak, And Possible- To-Speak Similar To Make Bosch Model No. Ccsd-Dl Complete. , Audio Visual Work : Supply Of Control Unit For The Ccs 1000 Digital Discussion:Built-In Mp3 Recorder With Internal Memory And Usb Recordingbuilt-In Digital Acoustic Feedback Suppression (Dafs) For Ensuring Superior Speech Intelligibility Plug-And-Play Functionality For Quick And Easy Connection Of Up To 80 Discussion Devices Native Support For Automatic Hd Camera Control. A Maximum Of Four Microphones Can Be Selected On The Control Unit. This Can Be Further Extended To 10 Microphones In The Web Browser Four Basic Microphonemanagement Mode Shall Be There: -(I) Open: Microphone Button Control With Request-To-Speak (Auto)(Ii) Override: Microphone Button With Override Of Activated(Iii) Voice: Voice Activated Microphones(Iv) Push-To-Talk (Push And Hold Button To Speak) Functions Plug- And-Play Functionality Web Browser Control Open Microphone Control Built-In Mp3 Recorder Discussion Controlsimilar To Make Bosch Model No. Ccsd-Curd Complete. , Audio Visual Work :Supply Of Extension Cable Assy 10M Similar To Make Bosch Model No. Lbb4116/10 Complete. , Audio Visual Work : Column Loudspeaker 30W, Metal, Sound Pressure Level At Rated Power /-1 W (1 Khz, 1 M)-105 / 92 Dbspl, Effective Frequency Range (-10 Db) 153 Hz‒ 17.7 Khz, Horizontal Opening Angle At 1 Khz / 4 Khz (-6 Db)-198°/ 130°,Vertical Opening Angle At 1 Khz / 4 Khz (-6 Db)-62°/ 18°,Rated Input Voltage 100 V, Rated Impedance, Full Power 333 Ω, Half Power 667 Ω, Quarter Power 1333 Ω. Similar To Make Bosch Model No. La2-Um30-D-In Complete. , Audio Visual Work : Booster Amplifier 240 W With Electrical Power Supply Input Voltage 230Vac ±10% At 50/60Hz Or 24Vdc Inrush Current 9A At 230 Vac, 11A At 24 Vdc Performance Rated Output (Rms) 240W Power Reduction On Backup Power -1 Db Frequency Response 60 Hz To 18 Khz (+1 / -3 Db At -10 Db Ref. Rated Output) Distortion 1% At Rated Power,1Khz S/N (Flat At Max Volume) 85 Db Power Consumption Max Power Consumption 760 Va Mains Operation Max Power 451W -3 Db 340W Pilot Tone 55W Idle 16W 24V Dc Operation Max Power 12.1A (290W) -3 Db 11.4A (274W) Pilot Tone 1.7A (41W) Idle 0.3A (7W) Line Input S 2X Connector 3-Pin Xlr, Balanced Sensitivity 1 V Impedance 20K Ohm Cmrr 25 Db (50 Hz To 20 Khz) Gain 40 Db 100 V. Similar To Make Bosch Model No. Lbd1935/00 Complete. , Audio Visual Work : 12-Channel Mixing Console: Max. 6 Mic / 12 Line Inputs (4 Mono +4 Stereo) / 2 Group Buses + 1 Stereo Bus / 2 Aux (Incl. Fx).Similar To Make Yamaha Model No. Mg12xu Complete. , Audio Visual Work : Wireless Handheld Microphone System With Frequency Response 50 To 20,000 Hz, Polar Pattern Unidirectional (Cardioid),Output Impedance @ 1 Khz, Typical-600 Ω,Audio Output Level -43.5 Dbv/Pa, Signal-To-Noise Ratio[1]@ 1 Khz-72 Db, Maximum Spl[1]-1000 Ω Load, @ 3% Thd-139.0 Db, Dynamic Range*1+@ 1 Khz, 1000 Ω Load-117.0 Db, L Equivalent Output Noise[1],Typical, A- Weighted-22 Db, Power Requirements +5V Dc (Nominal), 10 V Maximum. Similar To Make Shure Model No. Svx24/Pg28 Complete. , Audio Visual Work : Wireless Lapel Microphone With Frequency Response 50 To 20,000 Hz, Polar Pattern Unidirectional (Cardioid),Output Impedance@ 1 Khz, Typical-600 Ω, Audio Output Level -43.5 Dbv/Pa, Signal-To- Noise Ratio[1]@ 1 Khz-72 D, Up To 8 Selectable Channels, Up To 4 Compatible Systems, Antenna Switching Diversity, Adjustable Squelch Level, Mic / Line Switch. Similar To Make Shure Model No. Svx14/Cvl Complete. , Audio Visual Work : Hydraulic Pop-Up Box Having Multi-Connectors For Data And Power Connection, Hdmi. Connectors: 2X Power, 1X Rj45 Hdmi, 1X Vga, 1X 3.5Mm Audio Jack 1X Video, Hydraulic (Pneumatic) Open Close Movement , With Bottom Box. Similar To Make maintenance Complete. , Audio Visual Work : Interactive Display Panel:Screen Size-86, Panel Technology-Ips, Back Light Type- Direct, Aspect Ratio- 16:9, Native Resolution-3840X2160 (Uhd), Refresh Rate-60Hz, Brightness-440 Nits, Contrast Ratio- 1,200:1, Dynamic Cr- 5000:1, Color Gamut- Ntsc 72%, Viewing Angle(H X V)- 178 X178, Color Depth- 10Bit, 1.07Billion Colors, Response Time-8Ms (Gto G), Operation Hours (Hours/Day)- 16/7, Surface Treatment (Haze)-28%. Connectivity (Jack Interface):Input- Digital-Hdmi- Es(3), Hdcp2.2, Analog-Rgb, Vga(1), Audio- In, Rs232c In, Rj45(Lan), Usb3.0 Type A(4) , Usb2.0 Type A(1), Usb Type C (1), Audio Out, Touch Usb.Mechanical Specification:Bezel Color-Black, Bezel Width-15/15/15/44Mm, Weight(Head)- 58.6 Kg, Packed Weight- 75.9 Kg, Monitor Dimension(W X H X D)- 60 X 100Mm, Carton Dimensions(W X H X D) (Box Outer Size)- 2110 X 1283X225mm, Handle, Vesatm Standard Mount Interface-800X600. Key Feature:Hw-Wi-Fi, Build-In-Slot Type, Power Indicator, Auto Brightness Sensor, Sw- Webosver, Android- 11.0, Screen Share.Environment Conditions:Operation Temperature-0 °C To 40 °C, Operation Humidity-10% To 90%, Power Supply-Ac 100-240V~, 50/60Hz, Power Type-Built - In Power, Power Consumption- Typ.-385W, Max- 580W,Poweroff- 0.5W, Sound-Speaker-Inbuilt (15Wx2), Certification-Safety-Cb / Nrtl , Emc-Fcc Class A / Ce /Kc, Erp , Ops Type Power Built In Compatible,.Accessory:Power Cord 3 M*1, Usb Cable (Type A-Type B) 5 M*1, Hdmi Cable 3 M*1, Writing Pen*2Pcs, User Manual, Qsg, Carton Box, Remote Controller(Include Battery 2Ea), Wifi Module. Reponse Time-≤5Ms, Accuracy-±1Mm, Interface-Usb2.0, Protection Glass Thickness-3T (Anti-Glare), Operating System Support- Windows 7/8/10/Windows Xp/Linux/Mac/Android (Windowsxp/Linux/Mac Support One Point Touch), Multi Touch Point -Max 40 Points. Android System-Soc-Quad Core A55, Gpu-Mali G52mp2, Ram-4 Gb, Wifi-802.11 A/B/G/N/Ac/Ax (Wifi 6), Lan-Gigabit Lan, Bluetooth-Bluetooth 5.0.Make- Lg/ Samsung/ Panasonic , Audio Visual Work : Led Display Tv:Size-65 Inch, Resolution-3840 X 2160 (Uhd), Backlight Unit Type- Direct, Brightness-400Nit, Dynamic Contrast Ratio (Dynamic Mci (Hz))-1,000,000:1, Static (Panel) Contrast Ratio-1200:1, Refresh Rate-60Hz, Video: Hdr (10 Pro / Hlg)-Yes / Yes, Audio: Speaker (Sound Output)-10W + 10W, Broadcasting System: Digital Terrestrial, Cable, Satellite)-Dvb-T2/C, Hospitality Feature-Hotel Mode / Pdm / Installer Menu,0Ne Channel Map, Ip Channel Manager; External Speaker 0Ut (Int Variable/Fixed, 3.5Mm, Stereo, Single Dedtype (Gnd,L+,R+), 2W+2W With 80), Smart Feature- Web 0S Version (Web0s 6.0), Smart Home (Launcher Bar), Web Browser Pre-Loaded App (Youtube Only, ), Sdp Server Compatibility, Mood Display, Soft Ap, Wifi (Version) (802. 11Ac), Screen Share (Miracast), Smart Share, Bluetooth Audio Playback, Hdmi-Arc (Arc, Hdmi2), Signage Feature- Vertical Setup, Fail 0Ver, Play Via Url, Ntp Server Setting, Cisc0 Certi. Compatibility , Crestron Connected (Network Based Control), Dpm (Digital Power Management), Time Scheduler, Rtc (Real Time Clock), Ntp Sync Timer, Beac0n, Embedded Cm (Contents Manager), Embedded Gm (Group Manager), Supersign Sw C0mpability-Control / Control Plus, Cms(Premium), Simple Editor, Input Interface: Setside - Hdmi In (3 (2.0)), Headphone 0Ut (Phone Jack Type), Rs-232C(D-Sub 9Pin / Phone Jack) (Phone Jack, 4Pi), Jack Interface:Set Rear- Usb (2.0), Rf In, Digital Audio 0Ut (0Ptical), Externalspeaker 0Ut(3.5Mm Phone Jack), Rj45 (Usage Purpose) (Lan),Dimensi0n (Unit: Mm Kg): Vesa Compatible-300X300, Weightwithout Stand-21.5, Weight With Stand-21.8, Weight In Shipping-27.8, Size Without Stand-1454X838x57.7, Size With Stand- 1454 X 899 X 271, Size In Shipping- 1600X970x172, Bezel Width(L/R/U/B): 0N Bezel- 12.8/12.8/12.8/19.9, Power Supply (Voltage, Hz)-Ac 120 V-, 50 / 60 Hz, Power Consumption(Max)-198, Power Consumption(Typ)-169, Standby Power Consumption-Under 0.5W, Safety-Cb, Cu Tr, Emc-Ce, Remote Type-S-Con, Power Cable- Detached (1.5M, Straight Type), Onsite-3 Years.Make- Lg/ Samsung/ Panasonic , Audio Visual Work : Supply, Fitting, Fixing And Installation Of All In One Computer Desktop: Specification: Monitor - 24 Inches, Storage - 1 Tb Ssd, Memory - 16 Gb Ddr5, Processor - Intel Core I5, 14Th Generation, Windows Home, Wifi Inbuilt, Warranty-3Years, Make- Dell/ Hp/ Asus/Lenovo , Audio Visual Work : 4X4 4K Hdmi Matrix Switch Connects Any Of 4 Hdmi Sources To Any Of 4 Hdmi Displays, Supports 4K Resolutions Up To Uhd (3840 X 2160) And Dci (4096 X 2160) With Refresh Rates Of 30 Hz (4:4:4) And 60 Hz (4:2:0), Signaling Rates Up To 3.4 Gbits For Flawless 4K Output, Multiple Control Methods - System Management Via Front- Panel Pushbuttons, Ir Remote And Rs-232 Control. Similar To Make Aten Model No.Vm0404h Complete. , Audio Visual Work : Full Hd Ptz Ip Camera For Video Conferencing Which Supports1080p At 60Fps And Versatile 20X Optical Zoom, Delivers Hd Videooutput Via Ethernet, Hdmi, Usb And 3G-Sdi Simultaneously, Sensor, 1/2.8 2.16 Mp Cmos, Video Format-1080P : 60 / 50 / 30 / 25,720P : 60 / 50 / 30,Video Output (Hd) Interface,3G-Sdi / Hdmi / Ethernet / Usb3.0Optical Zoom,20X,Digital Zoom-12X,Horizontal Viewing Angle-57°,Vertical Viewing Angle-32.1°,Diagonal Viewing Angle-,65.4°, Aperture- F1.6~F3.8, Focal Length 5.33Mm~110Mm,Shutter Speed-1/1 ~ 1/10,000 Sec, Minimum Object Distance, Wide: 0.5M / Tele: 1.5M,Video S / N Ratio 50Db,Minimum Illumination-1.0 Lux (F1.6,50Ire, 30Fps), Focus System-Auto / Manual / Smart Af, Gain Control-Auto / Manual, White Balance-Auto / Manual, Exposure Control-Auto / Manual,Wdr,3D Nr Panning Angle+170° ~ - 170°,Panning Speed-225°/Sec, Tilting Angle+90° ~ -30°,Tilting Speed-225°/Sec. Similar To Make Lumens Model No.Vc-A53complete. , Audio Visual Work : Supply Of Usb &Hdmi Cable For Connectivity. Similar To Make Impression Complete. , Audio Visual Work : Supply Of 15U Rack For Controller & Amplifier. Similar To Make Netrack Complete. , Audio Visual Work : Supply Of 2 Core 1.5 Sq.Mm Flexible Speaker Cable As Per Site With Pvc Pipe. Similar To Make Krystal Complete. , Audio Visual Work : Installation, Testing & Commissioning With Transportation Loading Unloading Labour Charges Of The Entire System As Per Scope Of Work And Direction Of Engineer-In-Charge. , Inverter Air Conditioners Supply, Fitting, Fixing, Installation And Commissioning Of Split Ac Inverter Compressor, Condenser, Supports, With Cordless Remote Controller, Refrigerant Gas, Drain Pump, Etc As Per The Specifications Of The Following Capacities. Inverter 5 Star Rating. Make - Lloyd/ Lg/ Samsung 2.0 Tr 5 Star Inverter Model Split Ac: Specification:Compressor Type-Duo Rotary, Refrigerant-R-32, Power Supply: V-Hz-Ph-230 V~50 Hz 1 Phase, Operating Voltage Range:V-100 V - 300 V, Input Current (100%/50%):A-7.16 A / 4.13 A, Cooling Capacity (100%/50%):W-6340 W / 3170 W, Input Power (100%/50%):W-1630 W / 570 W, Iseer_5.06, Air Flow:M3/H-1270 M3/H, Air Throw Distance:M-12M, Electricity Consumption:Kwh-970.29 Kwh, Idu Noise:Db-43 Db, Odu Noise:Db-57 Db, Area Coverage: Sq. Metre-19.7 M2, Operating Range-Cools At 52 °C. 5 In 1 Convertible (40 / 60 / 80 / 100 / Auto), Smart 4-Way Swing, Turbo Cool, Rapid Cooling (18°C In 45 S), Installation Check, Low Gas Detection, Clean Filter Indication, Wifi Ready (Optional Wifi),Anti-Viral Dust Filter, Pm 2.5 Filter, Golden Fin Evaporator, Hidden Led Display, Stabilizer Free Operation, Strong Dehumidifier, Blow Function, 100% Copper, Eco Friendly Refrigerant(Ü),Idu Dimensions (Lxbxh) As Per Installed Unit:Cm-(116.1 X 24.0 X 34.0) Cm, Idu Dimensions (Lxbxh) As Per Sowm Label:Cm-(116.1 X 34.0 X 24.0) Cm, Idu Packing (Lxbxh):Cm-(127.0 X 41.5 X 33.5) Cm, Idu Net / Gross Weight:Kg-14.2 Kg / 18.0 Kg, Odu Dimensions (Lxbxh):Cm-(94.0 X 37.0 X 68.0) Cm, Odu Packing (Lxbxh):Cm-(102.0 X 45.5 X 74.0) Cm, Odu Net / Gross Weight:Kg-34.6 Kg / 40.4 Kg , Inverter Air Conditioners Supply, Fitting, Fixing, Installation And Commissioning Of Split Ac Inverter Compressor, Condenser, Supports, With Cordless Remote Controller, Refrigerant Gas, Drain Pump, Etc As Per The Specifications Of The Following Capacities. Inverter 5 Star Rating. Make - Lloyd/ Lg/ Samsung 1.0 Tr 5 Star Inverter Model Split Ac: Specification:Compressor Type-Single Rotary, Refrigerant-R-32,Power Supply: V-Hz-Ph-230 V~50 Hz 1 Phase, Operating Voltage Range:V-100 V - 300 V, Input Current (100%/50%):A-3.65 A /1.99 A, Cooling Capacity (100%/50%):W-3500 W / 1750 W, Input Power (100%/50%):W-830 W / 320 W, Iseer-5.2, Air Flow:M3/H-750 M3/H, Air Throw Distance:M-7M, Electricity Consumption:Kwh-520.93 Kwh, Idu Noise:Db-35 Db, Odu Noise:Db-50 Db, Area Coverage: Sq. Metre-11.0 M2, Operating Range-Cools At 52 °C, 5 In 1 Convertible (40 / 60 / 80 / 100 / Auto), Smart 4-Way Swing, Turbo Cool, Rapid Cooling (18°C In 45 S), Installation Check, Low Gas Detection, Clean Filter Indication, Wifi Ready (Optional Wifi),Anti-Viral Dust Filter, Pm 2.5 Filter, Golden Fin Evaporator, Hidden Led Display, Stabilizer Free Operation, Strong Dehumidifier, Blow Function, 100% Copper, Eco Friendly Refrigerant(Ü),Idu Dimensions (Lxbxh) As Per Installed Unit:Cm-(85.6 X 21.9 X 28.5) Cm, Idu Dimensions (Lxbxh) As Per Sowm Label:Cm-(85.6 X 28.5 X 21.9) Cm, Idu Packing (Lxbxh):Cm-(93.4 X 35.5 X 31.1) Cm, Idu Net / Gross Weight:Kg-9.0 Kg / 11.3 Kg, Odu Dimensions (Lxbxh):Cm-(87.0 X 36.5 X 56.0) Cm, Odu Packing (Lxbxh):Cm-(91.0 X 41.5 X 59.0) Cm, Odu Net / Gross Weight:Kg-24.9 Kg / 29.0 Kg. , Installation Of Split Unit : Installation & Commissioning Of Split Air Conditioners Including Inverter Compressor, Condenser, Supports, With Cordless Remote Controller, Etc. , Installation Of Split Unit : Supply, Installation, Commissioning Of Soft Copper Piping (1/4, 1/2 Inch) For Split Units , Clamping, Fittings, Etc. Both The Pipelines Shall Be Insulated With Nitrile Tubular Insulation. , Installation Of Split Unit : Supply, Installation, Commissioning Of 4C X 1.5 Sq. Mm Control Wiring Indoor To Outdoor Unit , Installation Of Split Unit : Supply, Installation, Commissioning Of Pvc Pipes Including All Cost Of Labour, Material, Conveyance, Etc. Complete And As Per The Directions Of Engineer-In-Charge. , Installation Of Split Unit : Supply, Installation, Commissioning Of Pvc Drain Pipes With Supports As Per Drawings And Specifications Of 25Mm Inner Dia Sizes. Including All Cost Of Labour, Material, Conveyance, Etc. Complete And As Per The Directions Of Engineer-In-Charge. , Installation Of Split Unit :Supply, Installation, Commissioning Of Insulation Drain Pipes Including All Cost Of Labour, Material, Conveyance, Etc. Complete And As Per The Directions Of Engineer-In-Charge. , Installation Of Split Unit : Supply, Installation, Commissioning Of Rapping Tape , Installation Of Split Unit : Supply, Installation, Commissioning Of Odu Bracket. , Installation Of Split Unit : Supply, Fitting, Fixing, Installation, & Commissioning Of Outdoor 30 Kva (280V-470V) Un-Balanced Load Three Phase, Air Cooled Servo. Specification: Standard-Iso 9001-2008 Standards, Type-Un-Balanced Type Three Phase Air Cooled, Rating-30 Kva, Input Voltage Range-280V - 470 V, Output Voltage Range-400 Volts±1%, Input Frequency-45-55 Hz, Response Time-10M Sec, Correction Speed-35 To 45 Volt Per Sec, Efficiency-Better Than 98%, Metering / Control-Digital Ac Voltmeter With Output Measure Switch, Ampere Meter For Three Phases, Core Used-Mitor Grade Core For Buck / Boost Transformer, Winding-Electrolytic Copper Grade ( F Class Insulated), Temp. Rise-35˚ C Deg. Cent. Above Ambient, Winding Temp.-Rise 40˚ C Deg., Application-Indoor/Outdoor Type, Transformer Oil-Is 335 Making (Power Oil), Output Accuracy-+/- 1 % From No Load To Full Load, Wave Form Distortion Virtually Nil, Losses At No Load-0.12% Of The Total Capacity, Losses At Full Load-0.7% At Full Load, Terminations-Suitable Bus Bars Will Be Provided In The Termination Box, Operating Temp-0 To 55 Degree Centigrade Along With 2 Nos.. Of Earthing Terminal At Both Side Of Unit And Fabricated Outdoor Stand. Make- Jyoti/V-Guard/Microtek , Installation Of Split Unit : Supply And Laying Of 10Sqrmm Single Core Copper Flexible Wire Along With Proper Safety And Clamping Arrangement. Make- Havells/ Polycab/ Kei , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Supply Of Premix Tea/Coffee Vending Machine: (Multi Option- 3 Nos.. Beverages):Technical Specifications:Supply, Fitting, Fixing, Installation And Commissioning Of Premix Tea/Coffee Vending Machine Of 3 Lane, Net Weight-18.2 Kg, Gross Weight-21.2 Kg, Dimensions (W X D X H)-340 X 485 X 625 Mm, Package Dimensions (W X D X H)-390 X 535 X 695 Mm, 3 Drinks, Gi Body Material, Front Door-Abs Moulded, Power Source-220/110V-1P, Power-1500 Watt., Start-Up Time- Up To 10 Minutes, Dispensing Rate- Up To 22 Cups In One Time Of 100 Ml, Premix Canister-3 Nos.., Water Input-Bubble Top/Pump (Optional), Hot Tank Material-Ss 304, Canister Capacity-1.1 Kg., Auto Flush-Available, Dedicated Hot Water-Yes, - Sensor Operating Range (Only For Touch Less Model Ne/Ap)- 25 Mm (1 Inch).Make - Nescafe/ Godrej/ Nestle , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Installation Charges Of Coffee Vending Machine As Per Direction Of Engineer-In-Charge. , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Ingredients: Bru Coffee Premix , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Ingredients: Nescafe Premix , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Premium Teabags (200S) , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Sugar Sachet (1Kg) , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Lemon Tea Premix , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Disposable Nescafe Paper Cup 110Ml(50Nos.) , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items 3 Supply, Fitting, Fixing And Installation Of Mini Fridge : Specification: 92L Fridge Single Star Energy Rating, Direct Cool Technology And Single-Door Design With A Capacity Of 92 Liters. Its Dimensions Are 45.5 Cm X 49.5 Cm X 84.5 Cm (W X D X H) With A Net Weight Of About 21 Kg, And It Uses R600a Refrigerant With A Fixed-Speed Compressor. It Features Toughened Glass Shelves And An Internal Manual Control Panel. , Chairs: Supply, Fitting, Fixing Of High Back Revolving Chair, Overall Dimension:- 720W ±10 X 720D ±10 X 1290H ±10 Mm, Seat& Back Of Chair Is Made Of 12Mm Hot Pressed Plywood And Connected With Ms Powder Coated L Patta Of Size 65X8mm, Seat & Back Cushioned With Pu Foam In D-45 Kg/M3 & Prime Quality Leatherette Upholstery , Seat Size:- Seat Size:- 540W ±10 X 520D ±10 X 60 Thick. ±5 Mm, Back Size:- 530W ±10 X 730H ±10 X 60Thick. ±5Mm,Mechanism: Torsion Bar Single Point Control, Provides Maximum Adjustability And Scope For Comfort, Seat & Back Moves In Same Direction, Single/ Upright Position Locking, Tilt Tension Knob To Loosen Or Tighten The Tension According To Users Body Weight, Gas Lift:- Lift -Used Gas Lift Of 100Mm Size Of Class-Iv Grade , Plastic Gas Lift Cover, Armrest:- Leatherette Upholstered On Foam Cushioned Armrest Fixed Pp Structure And Ss Frame, Armrest Fixed With Seat & Back Which Gives Comfort & Strength Both To The Chair, Chair Base & Wheels: Metal Chrome Plated Chair Base Frame Made Of 2.5Mm Thick, Base Front Edges Are In Nylon, Base Consists Of 5 Prongs With 650±5 Mm Pitch Circle Diameter, 60Mm Dia. Black Nylon - Twin Wheel Pin Castor. Make- Methodex/ Godrej/ Ayesha , Chairs: Supply, Fitting, Fixing Of Medium Back Revolving Chair, Overall Dimension:- 720W ±10 X 720D ±10 X 1160H ±10 Mm, Seat& Back Of Chair Is Made Of 12Mm Hot Pressed Plywood And Connected With Ms Powder Coated L Patta Of Size 65X8mm, Seat & Back Cushioned With Pu Foam In D-45 Kg/M3 & Prime Quality Leatherette Upholstery , Seat Size:- Seat Size:- 520W ±10 X 510D ±10 X 60 Thick. ±5 Mm , Back Size:- 530W ±10 X H 610 ±10 X 60Thick. ±5Mm,Mechanism: Torsion Bar Single Point Control, Provides Maximum Adjustability And Scope For Comfort, Seat & Back Moves In Same Direction, Single/ Upright Position Locking, Tilt Tension Knob To Loosen Or Tighten The Tension According To Users Body Weight, Gas Lift:- Lift -Used Gas Lift Of 100Mm Size Of Class-Iv Grade , Plastic Gas Lift Cover, Armrest:- Leatherette Upholstered On Foam Cushioned Armrest Fixed Pp Structure And Chrome Plated Frame, Armrest Fixed With Seat & Back Which Gives Comfort & Strength Both To The Chair, Chair Base & Wheels: Metal Chrome Plated Chair Base Frame Made Of 2.5Mm Thick, Base Front Edges Are In Nylon, Base Consists Of 5 Prongs With 650±5 Mm Pitch Circle Diameter, 60Mm Dia. Black Nylon - Twin Wheel Pin Castor. Make- Methodex/ Godrej/ Ayesha , Chairs: Supply Of Signature Fabric Arm Chair. Specification: High-Quality Plastic Construction For Lasting Durability. Ergonomic Design With Cushioned Seat And Backrest. The Glossy Lacquered Finish Resists Uv Rays And Rust. Soft-Feel Fabric Adds A Touch Of Comfort And Beauty. Easy To Clean And Maintain, Suitable For Indoor And Outdoor. Dimensions : Width (Cm) 56, Depth (Cm) 58, Height (Cm) 80, Weight (Kg) 5.2. Make- Nilkamal/ Supreme/ Cello , Induction Stove : Supply, Fitting, Fixing Of 2000W Induction Cooktop.Specification:Induction Cooktop, 2000W, 8 Cooking Options, Overheat Protection, Child Lock Function, Auto Pan Detection & Auto Power Off, Digital Display And Led Indication For Easy Operation, Fixed & Variable Cooking Options With 10 Power Settings (120 W To 2000 W), Dedicated + & - Options To Control Power Levels, Temperature As Well As Time. Make- Havells/ Bajaj/ Prestige , Induction Stove : Supply Of Stainless Steel Drinking Water Bottle, 1.0Ltr. Specification: Drift Stainless Steel Bottle 950 Ml, Size & Dimensions In Cms (L X W X H)-7.5 X 7.5 X 27.5, Size & Weight-950 Ml - 392 G, Cap Type - Screw Cap • With Lid - Yes , Care Instructions - Hand Wash Only, Package Contents - 3 X Drift Stainless Steel Bottle. Make-Milton/Cello/Borosil , Induction Stove : Supply Of Ceramic Snacks Plate Of Size 7 Inches/ 17.8 Cm Make-Milton/Cello/Borosil , Induction Stove : Supply Of Cup With Saucer For Tea/Coffee In Ceramic Make-Milton/Cello/Borosil , Induction Stove : Supply Of Transparent Drinking Water Glass Of 300Ml. Make-Milton/Cello/Borosil , Induction Stove : Supply Of Stainless Steel Snacks Spoon Make-Milton/Cello/Borosil , Induction Stove : Supply & Fixing Of Metal Chrome Finish Plain Pedal Stainless Steel 15L Capacity Dustbin With Lid & Pedal Of Free Size Dimension 30X20x20 Cm. , Induction Stove : Supply And Fixing Of Rectangular Shape Non Slip Foot Mat Of Size 4Ft. X 2Ft. , Induction Stove : Supply And Fixing Of Cotton Luxury Office Chair Towel. , Interior Work : Supply And Installation Of 12.5 Mm Thick Gypsum Glass Fiber Reinforced (Gfr) Pixello 8 / 18 With 8 Mm Circular Diameter & 18 Mm Pitch, Total Open Area 15%, Having Broadband Sound Absorption, With Size Of Boards 1200 X 2400 Mm, Having Density 700 Kg / M³ & Weight 9 Kg / M², With Fire Class 1 & P, Climate 0°C, Rh (50-70), Nrc Up To 0.80, To Be Fixed With Philips Head Screw To Suspended Gi Frames As Per The Specification For Fixing Concealed Grid Ceiling System. The Concealed Wall Paneling System Shall Include Gi Wall Channel (Wc 25) Having Thickness 0.45 Mm, Length 3600 Mm, Unequal Flanges Of 15 & 20 Mm And Web Of 25 Mm, Which Should Be Fixed Along The Perimeters Of The Wall With Nylon Sleeves And Suitable Fasteners At Every 300 Mm Centers. Then Fixed Main Channels (Mc 45) To Be Suspended With The Help Of Gi Channel Sa 25 From Reinforced Cement Concrete / Perling. The Mc 45 Channels Have Thickness 0.9 Mm, Length 3600 Mm, Equal Flanges Of 15 Mm And Web 45 Mm From The Side Wall & Fixed At Every 1200 Mm Centers, With Gi Ceiling Channel (Cc 25) Having Thickness 0.45 Mm, Length 3600 Mm, Knurled Web 35 Mm, Depth Of 25 Mm And Equal Flanges 9.5 Mm, Fastened To The Main Channel In The Direction Perpendicular To The Main Channel At Every 600 Mm Centers. The Framework Will Maintain 50 / 75 Mm Gap From The Walls. Now Lifting The Boards On The cement concrete 25 With The Help Of Screw To Get A Flush Finish. The Jointing & Finishing Of The Same Will Be Done By Using Jointing Compound, Paper Tape. The Synthetic Polyfiber Pf5 X 25 Wool Of 50 Kg Density & Width 600 Mm, 5000 Gsm To Be Laid On The Top Of The Framework / Boards. Make: Anutone / Uno Panel / Techtom. Test Certificate Of The Used Products Shall Be Submitted After Procurement Of Materials. , Interior Work : Supply And Fixing Of 1 Mm (10% +/-) Polymer Based Acoustic Louvers Ceiling Systems Of Pare Innovations Of Panel Sizes Of 265 Mm X 3060 Mm, Along With Option To Custom Size To A Maximum Of 12800 Mm In Length In Approved Shade, Manufactured In India, Made With High Temperature Thermal Transfer Technology, Waterproof, Fire Retardant And Antibacterial. Termite Resistant, Rustproof Material. Panels To Be Installed With Gi Sections Of Suitable Gauge & Size, Subject To Change According To Site Conditions. Panels To Be Installed Using Suitable, Same Shade J-Trim With Dimensions 39 X 20 X 3060 Mm (All In Mm) For Edge Profiles And Connector With Dimensions 76 X 20 X 3060 Mm, Using Same Shade For Connecting Panels, Using Outside Corner With Dimensions 61 X 63 X 3060 Mm, Which Can Be Used In +90 Degree Corners, And Inside Corner Having Dimensions 28 X 76 X 3060 Mm, Which Can Be Used For 90 Degree Corners. Panels Are Maintenance Free And Come With 10 Years Warranty For Colour & Finish Of The Panels, Including Trims Of Pare Innovations. All Material, Accessories, Ancillary Components As Per Recommendation Of Pare Innovations. , Interior Work : Supply And Fixing Of 1 Mm (10% +/-) Polymer Based Acoustic Louvers Wall Panelling Systems Of Pare Innovations Of Panel Sizes Of 265 Mm X 3060 Mm, Along With Option To Custom Size To A Maximum Of 12800 Mm In Length In Approved Shade, Manufactured In India, Made With High Temperature Thermal Transfer Technology, Waterproof, Fire Retardant And Antibacterial. Termite Resistant, Rustproof Material. Panels To Be Installed With Gi Sections Of Suitable Gauge & Size, Subject To Change According To Site Conditions. Panels To Be Installed Using Suitable, Same Shade J Trim With Dimensions 39 X 20 X 3060 Mm (All In Mm) For Edge Profiles And Connector With Dimensions 76 X 20 X 3060 Mm, Using Same Shade For Connecting Panels, Using Outside Corner With Dimensions 61 X 63 X 3060 Mm, Which Can Be Used In +90 Degree Corners, And Inside Corner Having Dimensions 28 X 76 X 3060 Mm, Which Can Be Used For 90 Degree Corners. Panels Are Maintenance Free And Come With 10 Years Warranty For Colour & Finish Of The Panels Including Trims Of Pare Innovations. All Material, Accessories, Ancillary Components As Per Recommendation Of Pare Innovations. , Interior Work : Providing, Fitting & Fixing Of Pre-Moulded Decorative Corner Beading Of Grc, Having Cross Sectional Dimension 112 X 80 Mm And Fixing The Same By Providing Pvc Plug, Screw, Cornice Adhesive, Fevicol Etc., Complete In All Respect As Per Direction Of Engineer-In-Charge. , Interior Work : Supply & Installation Of Wall Panelling Of Anutone Lisoslats Variosurco High Density Fiber Board, Made Out Of Pure Pine Wood Particles, Fr Grade Pure Pine Wood Particle Core With Test Bs 476 Part 5, Melamine Laminated Finish, Perforated Wooden Grooved Hdf Slats L16-2 (2 Mm Grooves @ 8 Mm Centres), Tongue & Groove Edge For A Seamless Look Of Linear Dimension Size 128 / 192 Mm X 2440 Mm X 16 Mm Thick, Having Density 700 Kg / M³, Weight 9 Kgs / M², 2 Mm Front Side Sound Absorber & 1076 Dis Tractor Hole, Non-Woven Acoustic To Be Pasted On Slats. Teak Teca / Beech Haya Surco Is To Be Installed By Using Gi Strut System. The Technical Parameters Are As Follows: Core Variants: Fiber Board Climate (Ocrh): 50-70 Light Reflectance: 75% Green (Rc%): 25 Hygiene (Voc, Clean Room): Low Class: 1 Nrc: 0.85 Strength, Load Capacity (Kg): Anti-Sag, Ball Impact The Concealed Wall Panelling System Shall Include Gi Wall Channel (Wc 25) Having Thickness 0.45 Mm, Length 3600 Mm, Unequal Flanges Of 15 & 20 Mm And Web Of 25 Mm, Which Should Be Fixed Along The Perimeters Of The Wall With Nylon Sleeves And Suitable Fasteners At Every 300 Mm Centres. Then Fixed Main Channels (Mc 45) Having Thickness 0.8 Mm, Length 3600 Mm, Equal Flanges Of 15 Mm And Web 45 Mm From The Side Wall & Fixed At Every 1200 Mm Centres, With Gi Cross Channel (Cc 25) Having Thickness 0.45 Mm, Length 3600 Mm, Knurled Web 35 Mm, Depth Of 25 Mm And Equal Flanges 9.5 Mm, Fastened To The Main Channel In The Direction Perpendicular To The Main Channel At Every 600 Mm Centres. The Framework Will Maintain 50 / 75 Mm Gap From The Walls. Now Clad The Wooden Anutone Slats Surco On The cement concrete 18 With The Help Of Centre & Edge Clips To Get Better Locking Of Slats. The Tongue & Groove Are To Be Properly Aligned To Get A Flush Look. Synth Anutone Poly Fiber Pf5 X 50 Wool Of 500 Gsm To Be Filled Between The Horizontal & Vertical Studs As Infiller With The Help Of Wire / Stick 7 Adhesive. Make: Anutone / Uno Panel / Techtom , Interior Work : Supply & Installation Of Anutone Pine Wood Wool Magnesia Bonded Soak Fabric Cord Binary / Triangle Design Of Selected Colours (Ref. Colour Chart), Kerf Edge Fabric Wrapped, Pine Wood Fibers Panels Of Size 600 X 600 / 1200 X 25 Mm, Having Density 400 Kg / M³, Weight 10 Kg / M², Installed By Using Gi Strut System. The Gi Strut Work Includes Cross Channels cement concrete 50 Having Thickness 0.45 Mm, Length 3600 Mm, Knurled Web 50 Mm, Depth 50 Mm & Base 100 Mm, Equal Flanges Of 13 Mm, Which Is Fastened To Wall Positioned Horizontally In A Regular Manner At 600 Mm Centers. Pvc Vinyl Core Uv Treated H Spline Having Thickness 2 Mm & Length 2400 Mm To Be Fixed, Using Z Bar Or H Spline On The Back Or Edge Of Panels / Tiles & Similar On The Back Of Channels Perpendicular To The Cross Channels cement concrete 50 At 600 Mm Centers. Kerfed Edge Fabric Wrapped Factory Panels Shall Then Be Inserted Into The H Spline Against The Wall To Perfect Fit. Panels Shall Be Back Lined With Acoustical Infill Of Anutone Synth Pf5 X 50 Mm Thick, Adhered To The Wall Using Stick 7 Adhesive. The Technical Parameters Are As Follows: Core Variant: Pine Wood Fibers Fire Class: 1 & P Acoustic - Nrc 20 Mm C10: 0.85 Climate: 0°C, Rh 50-90 Termite Resistance: Yes Light Reflectance: Colour Dependent Green Rc%: 10 Hygiene (Voc, Clean Room): Low Strength, Load Capacity (Kg), Ball Impact Make: Anutone / Uno Panel / Techtom. Test Certificate Of The Used Products Shall Be Submitted After Procurement Of Materials. , Interior Work : Supply And Installation Of 20 Mm Thick Pine Wood Wool Magnesia Bonded Colour Tiles / Panel Having Size 600 X 2400 / 1200 Mm, Having Density 400 Kg / M³ & Weight 8 Kg / M², With Fire Class 1 & P, Climate 0°C, Rh (50, 90), Nrc - 0.97 & Green (Voc, Rc%) Low, 10 To Be Fixed With Philips Head Screw By Using Concealed Ceiling System. The Concealed Ceiling System Shall Include Gi Wall Channel (Wc 25) Having Thickness 0.45 Mm, Length 3600 Mm, Unequal Flanges Of 15 & 20 Mm And Web Of 22 Mm, Which Should Be Fixed Along The Perimeters Of The Wall With Nylon Sleeves And Suitable Fasteners At Every 300 Mm Centers. Then Suspend Main Channels (Mc 45) Having Thickness 0.9 Mm, Length 3600 Mm, Equal Flanges Of 15 Mm And Web 45 Mm From The Soffit At Every 1200 Mm Centers With Suspender Angle (Sa 25) Having Thickness 0.45 Mm, Unequal Flanges Of 25 & 10 Mm. Gi Ceiling Channel (Cc 25) Having Thickness 0.45 Mm, Length 3600 Mm, Knurled Web 35 Mm, Depth Of 25 Mm And Equal Flanges 9.5 Mm, Is Fastened To The Main Channel In The Direction Perpendicular To The Main Channel At Every 600 Mm Centers. Now The Jointing & Finishing Of The Same Will Be Done By Using Sealant To Look Flush. Now, 20 Mm Strand Square Edge Of Size 600 X 2400 X 15 Mm Thick Shall Be Fixed. Apply Synthetic Poly Fiber Pf5 X 10 Acoustic Wool Of 50 Kg Density To Be Kept On The Top Of The Ceiling By Laying On The Framework. Make: Anutone / Uno Panel / Techtom. Test Certificate Of The Used Products Shall Be Submitted After Procurement Of Materials. , Interior Work : Supply And Installation Of Broadloom Carpet In Roll Form Of Approved Make, Shade & Pattern For Conference Hall. Carpet Shall Be Of Loop Pile, Of Size 500 Mm X 500 Mm, Having Pile Yarn Or Equivalent Material, Having Minimum Pile Height Of 2.9 Mm And Maximum Total Height Of 9 Mm With Backing Of 6 Mm Thick Open Cell Pu Foam. Carpets Shall Have Inbuilt Soil Protection, Fire Resistance And Antistatic Properties. Carpets Used Shall Also Be Certified From Leed / Griha, Certified With A Test For Indoor Hygiene Properties. , Interior Work : Supplying And Fixing Murals With Frame Of Natural Fibre/Putty Of Approved Size Including Cost Of All Materials, Labour, T&P Etc Required To Complete The Work As Per Drawing, Design And Direction Of Engineer-In-Charge. , Interior Work : Manufacture, Supply And Installation Of Noise (Stc 45) Fire Rated Acoustical Doors Of Size 1200 X 2100 Mm (Main Auditorium Doors). Framework Consists Of Wooden Sections Of Size 150 Mm X 75 Mm (Nominal Finished Frame Section Of 143 Mm X 65 Mm) With Self-Adhesive Type Perimeter Seals On The Perimeters Of The Frame And The Shutter Edges (Note: Shutter Is Double Edged). Fixing Arrangements Shall Be By Means Of 4 Nos.. Of G.I. Holdfast 225 Mm X 20 Mm X 4 Mm With Split End On Either Side Of The Wall, Including 8 Nos.. Of Stainless Steel Ball Bearing Hinges Of Ss 304 Quality Of Size 102 Mm X 102 Mm X 3 Mm Thick, Capable Of Taking Load Up To 120 Kg Of The Shutter, With Ss Pin, Lock Strike Plate, Shock Absorbers As Specified. 60 Mm Thick Double Leaf Shutter Of Appropriate Size Made Out Of Perimeter Railing Of Seasoned Red Marenti Hardwood (Moisture Content Limited To 18%) Of Size 100 Mm X 30 Mm And 2 Nos.. Of 6 Mm Thick Promina-60 Board, Lined With Sound Deadener (Sound Deadening Membrane 4 Mm Thick) Sandwiched Between 2 Boards On Each Side Of The Shutter Framework Using Suitable Fasteners And Duly Hot Pressed With 3 Mm Commercial / Marine Ply To Get The Required Surface For Laminate / Veneer / Paints. Cavity Is Filled With 96 Density X 50 Mm Thick Rock Wool. Doors Shall Be Provided With Acoustical Perimeter, Centre & Drop Down Seals. Make: Stairwell Studio, Tesco, Signum Doors. , Interior Work : Supplying, Fitting And Fixing In Position 32 Mm Thick Flush Door With Teak Wood Beading And 1 Mm Thick Sunmica To Both Sides Pasted With Adhesive, Including Fixing Of Fixtures Like Godrej Make Mortice Lock Having Model No. 9168, Godrej Make Door Closer Having Model No. 8340, 100 Mm Aluminium Hinges, Handle, Tower Bolt, Stopper, Including Cost Of All Materials, Labour, All Taxes, Transportation, Loading & Unloading Etc., Complete As Per Specification And Direction Of The Engineer-In-Charge. , Interior Work : Providing And Putting In Position Column / Wall Panelling As Per Approved Drawing, Made Out Of 12 Mm Thick Bwr Ply Over Framing With 1 Mm Thick Approved Colour Laminate, Including Cost Of All Materials, Labour, T & P Etc. Required For The Work, Complete In All Respect As Per The Direction Of The Engineer-In-Charge. , Interior Work : Providing And Fixing Wooden Venetian Blinds With Pelmet Of Vista Brand As Per The Approved Shade And Design, Along With All The Accessories Including Cost, Conveyance, Loading, Unloading, Taxes Of All Materials, Cost Of All Labour, Sundries And T & P Etc. Required For The Work, Complete As Per Specification And Direction Of The Engineer-In-Charge. , Interior Work : Supplying And Fixing Of Conference Table Of Size 40-0 X 8-0 X 2-6 (Veneer Finish), Made Out Of Calibrated Bwp Plywood With Approved Shade Of 1 Mm Thick Flitches Veneer. It Should Be Provided With Leg Structure Made Out Of 25 Mm Thick Ply & 32 Mm Ply Finished With Veneer For The Top. It Should Have Provision For Necessary Power (Pop-Up Box). All Exposed Edges Should Be Mechanically Edge Banded By Matching 1 Mm Thick Veneer Edge Banding With Hot Melt Glue (Jowat / Henkel). All Pressing Veneer Onto The Ply Has To Be Executed Mechanically By Hot Press And Polymerised D3 Adhesive (Kleiberit / Jowat / Henkel). The Non-Exposed Area Will Be Covered Up By 0.8 Mm Balancer Laminate. The Same Furniture Will Be Finished With Two Coats Of Sealer Followed By One Top Coat In Pu. The Pu Lacquer To Be From Sirca / Teknovance (Italy). It Should Have A Knock Down Arrangement Of Fitting. All Hardware Fittings Will Be Hettich / Hafele / Blum Make. Make By Vibe. , Interior Work : Supplying And Fixing Of Stage Table Of Size 12-0 X 2-0 X 2-6, Top Made Out Of 25 Mm Calibrated Bwp Plywood With Approved Shade Of 1 Mm Thick Flitches Veneer, Having Side Panel Continuing Up To The Floor Connected By A 16 Mm Modesty Panel. It Should Be Provided With Leg Structure Made Out Of 25 Mm Thick Ply & 32 Mm Ply Finished With Veneer For The Top. All Exposed Edges Should Be Mechanically Edge Banded By Matching 1 Mm Thick Veneer Edge Banding With Hot Melt Glue (Jowat / Henkel). All Pressing Veneer Onto The Ply Has To Be Executed Mechanically By Hot Press And Polymerised D3 Adhesive (Kleiberit / Jowat / Henkel). The Non-Exposed Area Will Be Covered Up By 0.8 Mm Balancer Laminate. The Same Furniture Will Be Finished With Two Coats Of Sealer Followed By One Top Coat In Pu. The Pu Lacquer To Be From Sirca / Teknovance (Italy). It Should Have A Knock Down Arrangement Of Fitting. All Hardware Fittings Will Be Hettich / Hafele / Blum. Make By Vibe By Transform Furnitures Pvt. , Interior Work : Providing And Fixing Wooden Podium Of Size 19-0X10-0X0-6Including Cost Of All Materials, Labours, T&P Etc Complete As Per Direction Of Engineer-In-Charge. , Interior Work : Supplying All Materials, Labour, T & P And Providing And Fixing In Position M.S. Panelled Door (Double). Supplying & Fixing Of Pantry Unit Made Out Of 16 Mm Calibrated Bwp Plywood With Approved Shade Of Laminate, With Exposed Side & Inside 0.8 Mm Balancer Laminate. All Laminates Have To Be Hot Pressed With D3 Glue (Jowat / Henkel / Kleiberit Glue). The Said Storage Should Have Two Side Panels & A Bottom Panel. The Top Will Be Moulded Granite Top. It Should Be Provided With A Back Panel Made Out Of 6 Mm Thickness. The Cabinet Should Be Provided With Two Openable Shutters Mounted With The Cabinet By Full Overlay Hinges. The Shutter Has To Be Laminated With 1 Mm Thick Lamination Hot Pressed Onto It. All Exposed Edges Should Be Mechanically Edge Banded With Pvc Edge Banded Tape (Rehau / Dolkan) Using Hot Melt Glue. It Should Have A Knock Down Arrangement Of Fitting. All Boring Has To Be Done On Cnc For Precision Of Fitting. The Hardware Will Be Of Hettich / Olive Make. The Carcass Will Be Provided With Suede Finished Edge Banded Shutters. All Accessories Are In Ss, Make By Vibe By Transform Furnitures Pvt. Ltd. , Interior Work : Providing And Painting Two Coats With Plastic Emulsion Paint Over A Coat Of Primer Of Approved Quality And Approved Shade In All Floors At All Height By Making The Surface To The Interior Plastered Surface Of Walls Smooth, Including Cost, Conveyance, Loading And Unloading And Taxes Of All Materials, Cost Of All Labour, Sundries, T & P, Scaffolding Etc. Required For The Work And Complete In All Respect As Directed By The Engineer In Charge. , Interior Work : Providing And Fixing Glass Reinforced Concrete (G.R.C) Screens In Approved Size, Pattern, Design, Shade And Thickness Of 50 Mm On Frame And Design Element In 30 Mm Thick, Having Weight Approximately Between 3.5-4 Kg Per Sq. Ft. The Above Weight And Thickness Is Considering Dimensions Of Screens Up To 2133 Mm In Height And 1219 Mm In Width And Having At Least 50% Void Space. The Screens Should Be Made From ‘53 Grade White Portland Cement Manufactured By ‘Jk Cement Or Equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber Manufactured By ‘N.E.G Japan Or Equivalent, Super Plasticizers Manufactured By ‘Basf Or Equivalent, Polymers Manufactured By ‘Basf Or Equivalent, And U.V Resistant Synthetic Inorganic Pigments Should Be Used For Pigmentation Manufactured By ‘Bayferrox (Germany) Or Equivalent. The Material Castings Should Take Place In Frp Molds. The Fixing Of Screens Should Be ‘Dry Fixing, I.E., To Be Done With M.S. Galvanized Clamps, Fixtures And Fasteners Of The Shutter Frame. , Interior Work : Signage With Letter Writing Of Brass Finish Of Approved Size As Per Direction Of Engineer In Charge
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
36.
Defence #10003682 AOC
Tender For Demolition And Re-Construction Of Smc Building At Afs Yelahanka On Epc Mode; 2 GENERAL SUMMARY NOTE: Schedule ‘A’ Part II to IX are prepriced by MES under Ser No. 2 to 9. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. 3 Lumpsum price worked out by the contractor for “Site Clearance as listed in Schedule ‘A’ Part - II. 4 Lumpsum price worked out by the contractor for Road/Path/Hardstanding as listed in Schedule ‘A’ Part - III. 5 Lumpsum price worked out by the contractor for Area Drainage as listed in Schedule ‘A’ Part - IV. 6 Lumpsum price worked out by the contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part – V. 7 Lumpsum price worked out by the contractor for “Fencing” as listed in Schedule ‘A’ Part – VI. 8 Lumpsum price worked out by the contractor for “External Water Supply/Hot Water Supply” as listed in Schedule ‘A’ Part – VII 9 Lumpsum price worked out by the contractor for “External Electric Supply” as listed in Schedule ‘A’ Part –VIII 10 Lumpsum price worked out by the contractor for “Demolition of existing buildings” as listed in Schedule ‘A’ Part – IX 11 Sch A Part - I : BUILDINGS OR WORKSDESIGN & CONSTRUCTION OF TWO STOREY (G+1)SMC BUILDING, AMBULANCE PARKING SHED AND DEMONSTRATION AREA INCLUDING ALL INTERNAL SERVICES AS DETAILED IN SCOPE OF WORK AND OTHER DOCUMENTS OF THE TENDER,COMPLETE ALL AS SPECIFIED AND SHOWN ON DRAWINGS. 12 SCHEDULE A Part- X (FITTINGS AND FIXTURES & MISC ITEMS) 13 ROADMaterial and labour for preparation of new road surfaces and applying reflective thermoplastic road marking paint (White or golden yellow) of minimum 2.50 mm thick (conforming to BIS-3262), single coat as in centre line and edge line road marking of 150/ 100mm width using HOT MARK by indigenous modern propelled road marking machine as directed including all ingredients such as binder, glass beads, titanium dioxide, calcium carbonate, inter filler as specified in table 803.4of MORTH specification,thermoplastic requirement for glass beads shall be as specified in (intermix) type-I, MOST/BS 6088Aand road marking shall done as per provisions contained in IRC-35-1997 complete all as specified and as directed. 14 FENCINGSupply and fix Stainless steel 304, 12 inch size each letter for Bilingual name board (Hindi-14 Nos letters and English-21 Nos letters) embedded in Granite on both gate complete all as specified and directed. 15 EXTERNAL WATER SUPPLYMaterial and labour for cutting existing 150mm bore water mains and inserting TEE 150mm x 100mm including necessary fittings, joints etc for connection of TEE complete all as specified and as directed. 16 Supply and fix Cast iron sluice valve flanged of class 1.0 PN, 80mm complete all as specified and as directed, 17 Supply and fix 80 mm dia cast iron body with flanged ends drilled ISI marked as per IS 14846:2000, PN 1.6 with brass spindle and check nut including operating wheel etc and fixed with flanges both end and new bolt, nuts, washers and rubber insertion packing complete all as specified and as directed. 18 EXTERNAL ELECTRIC SUPPLYReturning and filling of trenches in two parts (i) using riddled soil obtained fromexcavated soil upto depth of 30cm (8cm below cable and remaining above cable) for cushioning of cable and (ii)refilling the trench of remaining depthwith normal excavated soil all as specified and directed.Note: - Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS 1255-1983 and refilling in trenches as in cable cushioning. 19 Material and labour for Boring of holes under road, pavement, hardstanding by trenchless technology using ultrasound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure Complete all as specified and directed. 20 Supply and installation , testing and commissioning of HT 11 KV, rated voltage 12 KV,630 Amp, 21 KA / 3 Sec outdoor type extensible internal arc 21 KA for 1 sec for Tank floor mounted with internal copper busbar, SF6 insulated completely motorized 4 way RMU consisting of 01 Nos VCB 630 Amps as incomer and 03 No 630 Amp VCB as outgoingSCADA compatible, over load and earth fault protection relaywith air insulated metering module (MFM for VCB feeders) all live parts busbar ,VCB connections of RMU shall be inclusive in one SF6 tank to avoid multiple inter connections SF6 tank shall be sealed for life robotically welded non magnetic and non ferrite stainless steel grand 304 min 2.5 mm thick having IP-67 degree of protection filled with SF6 gas has insulation with leakage rate less than 0.1% per year tested as per IEC 62271 200 I No fault passage indicator (FPI) required for complete unit manual welding or heremetic ceiling of tank shall be not accepted . The unit shall have front cable entry (suitable for termination of 1 hr x 3C 95.120/ 150 Sqmm cable) for easy of installation and shall have site replaceable bushing for easy of troubleshooting during break down. RMU should be completed with all accessories such as terminal boots, VPIS , cable supports , all front cable terminations , mechanical indications vacuum circuit breakersON/OFF, Manometer as per with IEC standards 62271200, 60056, 60129, 60265, 60298, 60420, 60529 & 60694 altitude of installation upto 1000 m as per IEC 60120bushing bolted type top monitored outside the tank for connections of external busbar also the outer includes shall cover the full length of the switchgear , to ensure IP3X + IP-54 protection for cable boxes the unit shall be internal arc proof 24 KA for 1 sec with AFLR classification tested and totally safe for human being. 21 The gas release and personnel safety from internal arc shall not dropped on plinth design the release of gas to be from the top the unit . So that even if the person is operating the unit opening the cover and there are personnel near the side of the RMU / plinth top release will ensure their safety. The hot gas release in case of an internal arc, in No of case should be from any side or bottom of the unit as the same if unsafe for operating personnel / pedestrian or general public. Bidder shall provide type test report to be prove compliance to the internal arc fault IAC-AFLR as per IEC62271-200 internal arc testing shall be done with enclosure door in open conditions , with switching devise in operations mode as per specified standard RMU.(a) 01 Nos Incoming 630 AmpsVCB,motorised vacuum circuit breaker, triple pole single break 3 position (On, Off and earth having STC capacity 21 KA for 3 seconds with copper busbar and copper earth bar fitted high fixed type voltage indicator device as per IEC61958-1 fully rated with earth switch spring assisted mechanism with built in operating handle, arc proof hinged type cable cover air insulated cable boxes and boots suitable for bottom front entry termination of 3 core cable 95/120/185 sqmm. (b) 02 Nos Outgoing 630 Amps motorised vacuum circuit breaker, triple pole single break 3 position (On, Off and earth having STC capacity 21 KA for 3 seconds with copper busbar and copper earth bar fitted high fixed type voltage indicator device as per IEC61958-1 fully rated with earth switch spring assisted mechanism with built in operating handle, arc proof hinged type cable cover air insulated cable boxes and boots suitable for bottom front entry termination of 3 core cable 95/120/185 sqmm.(c) Bus connected PT unit-01 No for metering consisting of following:- (i) Type M : Air insulated metering module 12 KV, 630 A 21 KA for 3 sec.(ii) 3 voltage transformers of the ratio 11KV/1.732/110V/1.732.25VA class 1.0 with HT fuses on primary side and MCB on secondary side. 22 (iii) 3 Digital MFM with 485 port to measure Amps, Volts, Frequency, PF, KWH, KVAR.(iv) 1 LED bulb for illumination. (v) 1 Space heater with thermostat. (vi) 1 RYB Phase indicator. (vii) 1Cable support bus bar, stand for 3 Way unit, 1 Manometer & 1 Preparing Handle. (viii)1 Set bushing for external busbar connection along with bus bar cover & sleeved bus bars for coupling. (ix) 2x12 V Battery with charger of suitable burden for motor operation, input 230 V AC & output 24 V DC.(d)Capacitive Voltage indicator fixed type VPIS 9-15 KV. (e) Necessary inter locking arrangement for safety and operation. (f)One No Operating handle for manual operation. (g) PCC 1:2:4 type B1 using 20mm graded stone aggregate for foundation and bus duct of cable for RMU as per recommendation of manufactures & as directed by Engineer-in-charge. (h) Safety interlocks shall be provided as relevant IEC/IS standard and manufactures directions. (j) Above switchgears shall confirm to all relevant IEC/IS standard.(k) Manual operation of Vacuum Circuit Breaker should be possible without dismantling the motor from RMU. The motor should be fitted in such a way that it should not be required to dismantle during manual operation.(l) Coupling of RMU and metering module should be with the help of bolted type arrangement so that the coupling at site shall be easy. Plug in type bushing shall not be acceptable.(m) Minimum 3 Module should be accommodate in one tank to avoid multiple coupling at site. (n)Having following additional facilities:-1. Trip circuit supervision. 2. Disturbance recorder. 3. Event log with date and time.4. Measurement and control feature. 23 (o) Current Transformers (CTs) of dual ratio 50/25-5A of 15 VA output, accuracy class 1.0 for metering instrument and 5P10 for 15 VA accuracy for over current and earth fault protection - sets of 03 Note:-(i) Any other parts/items not specified above but have been considered essential for smooth and safe functioning of the RMU system shall be included in the items and are covered against the quoted rate.(ii)Cable compartment shall be provided at the front side with front bolted type box covers providedwith an inspection window forenabling operator to have visual inspection without operating cover in live condition for all incoming and outgoing RMU panels.(iii) Complete with internal and external connection with each other or as per ground requirement.(iv) Drawing and Design drawing shall be submitted for approval of Accepting Officer before placing Order.Following additional equipment delivered separately or mounted in respective panel.(i) Cable support bars, standard for 4-Way unit.(ii) Manometer.(iii) Operating handle. 24 Supply and fix 7 meter high hot dipped octagonal poles with 130mm bottom dia & 70mm top dia made up of 3mm thick HT Sheet alongwith base plate of size 200x200x12mm including foundation bolts & bracket of size M20x600mm EN 8 grade J type foundation bolts and numbering of poles, in white paint over black painted back ground at a height of 1.5m from bottom of pole with 5 cm large bold letters 2 (inch) wide withetc complete as required andall as specified and directed. complete accessories as required complete all as specified and as directed. 25 Supply and fix street light fitting 72 watt LED, new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP66 protection including GI Bracket of suitable size required for fixing LED light on pole along with nut and clamp complete all as specified and directed.Note :- Rates quoted by contractor are deemed to be inclusive of 3 core cable pvc insulated unsheathed copper multistranded conductor ISI marked from MCB box to street light all as specified. 26 Supply and fix pole box of size 450x 300 x 200 mm fabricated out of 2 mm thick MS Sheet having 4 Nos aluminium busbar of suitable size with 1 No. MCB SP 10 Amps front openable hinged cover outdoor type weather proof suitable for mounting on steel pole including fixing MS clamp02 Nos with nuts, bolts and washers complete all as specified and as directed. 27 Earthing complete with galvanized steel earthplate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically in a pit (earth pit of depth not less than 2.25 metre below ground level) with top edge of the earth platenot less than 1.50 metre below normal ground level surrounded from all sides by mixture of charcoal and common salt 15cm thick each layer and electrode connected to and includinggalvanized iron earth strip, 32 x 6 mm (earth lead) by means of bolts, nuts, check nuts and washers of galvanisedsteel protection pipe light grade 40mm dia and GI pipelight grade 20mm dia bore for watering, funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sq m) and frame including all excavation and earth work all as shown in electrical plate No 3 connected to earthing test point including testing on completion complete all as specified and as directed.Note : The unit rate includes for 40mm light grade protection pipe and GI earth strip 32 x 6mm from top of earth plate upto 7.50 metre above ground level.The earth pit shall be constructed atleast 1.5m away from the top of earth electrode. 28 Earthing with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4mm earth lead by means of bolts, nuts check nuts and washers of galvanized iron or steel with protection pipe of GI, medium grade 15mm bore, watering pipe 20mm bore of GI medium grade, earth plate surrounded by alternate layer of coal dust and common salt 15 cm thick each layer all as per electrical plate No 3 of SSR Part-I and connected to earthing test point all as specified or indicated and testing on completion including funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sqm) and frame including all excavation and earth work etc. including testing on completion complete all as specified and as directed. Note :(i) Earth chamber shall be constructed at least 1.50m away from the top of earth electrode.The earth pit and pipe for watering shall be provided in slanting manner.The unit rate include for GI pipes, GI earth lead from top of earth plate upto 7.50m above ground level, including PCC, RCC work etc as specified in the item. 29 Supply, installation, commissioning and testing of feeder pillar board Kiosk type floor mounted, Outdoor type, fixed type, double door openable both rear and front side, weather, dust and vermin proofand compartmentalizedMain L.T Panel(CPRI approved) made out of M.S. CRCA sheet 3.15 mm & M.S. Base Frame Angle 75x40 mm duly painted with Light/ Siemens Grey Powder Coated Paint with 900 A TPN Copper Busbar (current density of Copper Busbar shall be 1mmx1mm=1.6 Amp.)Copper shall be Electric grade, Busbar supports shall be DMC epoxy Insulators.All Busbars & Incoming/Outgoing Links shall be covered/ insulated with Heat Shrinkable sleeves ofcoloured coded red, yellow, blue & black. Power & Control Wiring withCopper Flexible Wire (size of control wire shall be 2.5 sq. mm copper flexible for C.T. Circuit & 1.5 sq. mm for other circuits)as per specifications. Platform for the feeder pillar board with PCC 1:2:4type B-1, 15cm thick in foundation, Brick (sub class B) work in CM 1:6 rendering in cm 1:6 on exposed surfaces and 100mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate as in padding on top and grouting blots etc for panel. The platform shall be 450mm height above ground level and of adequate size leaving minimum 100mm all around the feeder pillar board with following :- 30 (a)ACB 415 Volts, 630 amp, rating 4 pole 50 KA rupturing capacity, microprocessor release -01 No.(I/C)(b) MCCB 415 Volts , 250 Amp 4P , 36 KA ,microprocessor release - 01 Nos (c)MCCB 415 Volts , 160 Amp 4P , 25 KA ,microprocessor release - 02 Nos(d) MCCB 415 Volts , 125 Amp 4P , 25 KA ,microprocessor release - 02 Nos(e)MCB415 Volts , 32 Amp 2P , 10 KA ,microprocessor release - 02 Nos(f)Voltmeter 0-500V digital type with selector switch 96mmx96mm square flush mounted- 01 No.(g)ampere meter digital type of size 96mmx96mm flush mounted CTs operated including CTs 0-630A with selector switch-01 No.(h) LED type/Neon type indicating lamps panel mounting type RYB-03 Nos.(i)fine wiring with single core PVC insulated conductor FLRS wire of suitable size copper conductor cable,thimble, lugs etc for instruments/indicating lamps-01Job. 31 Supply, fixing, testing & commissioning of LT panel board of size 1.1x1.1x.5 Mtr,weather proof, outdoor type powder coated, double door shutter, made out of CRCA sheet3.15 mm thickouter and 2.00 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outdoor, floor mounting type with closedAluminium bus bar chamber including necessary insulator suitable for 3 phase, 4 wire 50 Hz AC,CPRI approved including provn of digital ammeter 0-350A,digital voltmeter 0-500 Volts, CTs of suitable ratio, indicator lamps R-Y-B,selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following Work alsoincludes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc The bottom portion of enclosure shall be minimum 100 cm above ground level of legs of angle iron ). 32 (a) Copper bus bar capacity 900 Amps for Phase-R-Y-B-3 Nos &neutral -1 No(b) ACB FP 36 KA 630 Amps- 1 Nos(I/C) (f) Digital Ammeter flush pattern type square dial 96 x 96 mm alongwith selector switch - 01 No and suitable CT ratio 0-630 Amps (g) Digital Voltmeter flush pattern type square dial 96 x 96 mm alongwithselector switch - 01 No 0-500 V(h) complete control panel wiring withstranded copper conductor of suitable size along with one set indicator lamp for R,Y & B for each incoming and outgoing feeder 33 Supply and fix Post top light of capacity 45Watt offering excellent uniform illumination and aesthetic in one go , made up of pressure die cast aluminium body and open PC Cover, IP 66 and IK-07 rating suitable for tall amid varied environmental conditions and for pole of dia 76mm colour temp 3000K complete all as specified and directed. 34 Supply and fix LED Bollard Light with unique concept LED in IP 66 with sustainable performance in all section of Capacity 9W, 220V, 50 Hz CCT- 3000K, 800mm Complete all as specified and as directed. 35 Supply, erection, testing and commissioning of 16M high mast shaft in two section suitable for 44m/sec wind speed along with head frame, luminaries carriage suitable for 8 luminaries in symmetrical arrangement and other accessories manufactured in factory including Supply of raising lowering system comprising double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightning finial. (Wiring material from JB to individual luminaries & MCB in base compartment are not included and are a part of installation) complete all as specified and directed by the Engr-in-Charge. 36 Supply of fix single dome LED type dome aviation obstruction light complete all specified and directed by Engr-in-Charge. Make : Bajaj Cat No : BGAV302LED or its equivalent in make specified in PS. 37 Supply and fix foundation bolts 04 Nos 24mm dia 850mm length, manufactured from special steel along with nuts, washers, anchor plate and common template complete all as specified and as directed. 38 Supply and fix LED flood light 250 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all specified and directed by Engr-in-Charge. 39 DG SETSupply installation testing and commissioning of Silent type Diesel Engine Generating set 415 volts 320 KVA, 3 phase 0.8 power factor, 50 Hz,developing 434 BHP @ 1500 RPM ,self exicited , self regulated brushless AC generator including AMF panel, suitable for ambient condition at Yelahanka and confirming to condition under CPCB 4+, ISO 8528-1, 3046, IS 10002, BS 5514/5000 with capacity of 10% overloading for one hour in every twelve hour duration andincluding the following accessories :-Make : Kirloskar / Ashok Leyland/ Ruston/Cummins 40 (A) Alternator :-Synchronous alternator rated at 320 KVA suitable for continuous operation at 1500 RPM generating 415 volts at 0.8 p. f (lag) suitable for 50 Hz, three phase, 4 wire system. The alternator shall be brushless,single bearing,self excited & self regulated with an AVR .The alternator will be suitable for tropical climate and shall generally confirm to IS: 4722 : 2001 The salient features of the alternators are :-(a)+-1% voltage regulation (max) in static conditions.(b)IP: 23 protections with class ‘H’ insulation. · (c)Permanent lubricating bearing. · (d)Permissible overload of 10% for one hour in 12 hours of operation.(B) Diesel Engine: - Adquate capacity of Diesel engineliquid cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection,cold starting 1500 RPM, as per relevant IS/BS complete with standard accessories all as specified and required for safe handling and operation. Salient features of accessories shall be as under :- i) Fly wheel with housingii) Cooling system :- Moulded radiator with fan & belts.iii) Cooling Liquid pump : - Centrifugal type belt driven.iv) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia with MS pipe medium grade, Silencer : Residential typev) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by governer electric operated/ (as recommended by OEM) for 1% speed /frequecy regulation.,Fuel filters, Fuel hosesvi) Lub oil System :- Lubricating oil filter,Lubricating oil pumpvii) Air Intake System :- Air intake Manifold,Air cleaner dry typeviii) Governer : Electronic typeix) Starting System :- Electric Self starter , including battery charging alternator 12 Volts DC.x) Batteries :- Batteries maintenance free of capacity 12 V, 150 AH- 02 No complete with copper conductor multistranded leads of suitable length fromself starter to the battary terminals complete with initial charge and initial fill of electrolyte all as specified. 41 xi) Generator Monitoring Panel : - Comprising of all standard items as per standard manufacturing, iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, coolant temperature indicator, Battery volt display.xii) Safety Controls : - Engine low lube oil pressure,high coolant temperature and over speeding of engine.xiii) Coupling arrngement : - Flexible couplingxiv) Accessories :- AVM Pads built- in or separtely mounted to manufactrer base frames.xv) Base Frame : - Base frame is fabricated either in ISMCor in sheet metal.The base frame is rugged in construction and designed for mounting Diesel engine and alternator close coupled, with cross members mounted on AVM. The base frame shall have provision for mounting of acoustic enclosure & control panel on it and lifting hook for complete seti.e. along with canopy, engine and alternator.xvi) MS/Steel flexible pipe line to and from the fuel tank to the DG Set.xvii) Battery Charger shall be provided as per manufacturer guidelines.xviii) 2 No battery of 12 V in charged condition with its leads. C)ACOUSTIC ENCLOSURE : Acoustic enclosure shall be powder coated and fabricated out of 16 SWG CRCA MS sheet. The silent canopy shall be of nut bolt type construction. Powder coating is done after seven-tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE-RETARDANT foam as acoustic material & Rock wool for hot zone.Adequate hinged doors shall be provided to canopy, one door shall have glass window for control panel visibility. 42 (i)Manufactured by OEM suitable for 320 KVA DG Set.(ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board.(iii) The generating setbattery should be inside the enclosure.(iv) Fuel tank :-Daily service fuel tank of 8 hours of continuous operation, fabricated form 14/16 SWG sheet metal complete with drain, inlet and outlet connection and fuel gauge.(v) Construction Details/specification are as follows : - (a) Outer body :- CRCA Sheet of 1.6mm thick. (b) Doors :- CRCA sheet of 1.6 mm thick. (c) Sound Insulation :- 100 mm thick rock wool(minimum density 64kg/Cum)/ fire resistancefoam/puff as per OEM/ as per standard manufacturing to achieve desired decibel level.vi) The acoustic should be composite in construction and fully assembled integral unit.vii) The DG Set should be provided with external Emergency stop push button.viii) The enclosure should be suitably internally illuminated by LED Lamp fittings.ix) The noise level should be < 75 dB at 1m under free field conditions.x) The acoustic enclosure parts shall be of powder coated after pre treatment process.The base frame should be painted with epoxy based black shade.D) Control Panel :- Control panel shall befabricated from 16/14 SWG sheet and powder coated after seven tank treatment process:(i) Microprocessor based generator set monitoring and control system consists of LCD display and to monitor operator interface, fault history, alternator data, Engine data, porvision for service adjustement and caliberation of DG control functions, Engine controls, engine protective functions, alternator protective functions etc.(ii) Instrument fuses and control wiring. (iii) Indication lampsset for running and load on.(iv) Bus bar including suitable capacity of MCCB, including CTs, cable etc. 43 E) AMF Panel :- Automatic Mains Failure (AMF) Panel should be outdoor made of CRCA sheet 3.15 mm thick including necessary arrangement to Install, Testing and Commissioning complete all as per OEM recommendation. F) Civil Works :-All civil works including PCC (1:3:6) platform with a height of 60 cm above ground level and upto a width of 60 cm both sides of DG Set for easy operation of operator and necessary maint workand related foundationsfor panel and equipments including making good of distrubed area during installation and commissioning of genset . The depth and size of the foundation and PCC as recommended by the manufacturer.The contractor shall arrangeartificial load resistive for testing of DG Set at site and the cost is deemed to be included in the quoted rates.Note :- (i) The complete DG Set shall be procured from authorised OEM of the manufacturer of engine. A certificate in this connection shall be submitted to the GE.(ii) Circulation system toachieve desired inside temperature of acoustic enclosure, if required shall be provided as per OEM recommendation.(iii) The quoted rate shall be deemed to be inclusive of 12 hours test run at site as specified in PS and IS requirements in presence E/M Offr detailed by accepting officer, all testing arrangements/ equipments shall be made available by the contractor for tests.(iv) The quoted rate shall be deemed to be inclusive of first fill of lubricant oil, DHPP for 12 hours testing and final successful acceptance test.(v) Anything missed out above but technically required for efficient working of DG Set is deemed to be included in quoted rates.vi) Design / drawing of the AMF panel & DG SET showing the dimensions is to be obtained from DG SET/ panel board manufacturer / supplier & is to be got approved fromEngr-in-charge/GE before placing final order to the manufacturer.vii) The electrical connection of digital Multi Functional Meter in the AMF panel is to be done from load side so that monitoring of various parameters viz. Voltage, Current, KW, KVA, power factor, frequency etc can be done of both SEB mains & DG mains.viii)The quoted rate shall be deemed to be inclusive of first fill of engine oil & final successful acceptance test.ix) The quoted rate shall be deemed to be inclclusive one set of all types of filters , complete set of Maint tools & fuel refilling pump for filling fuel to DG set. 44 Earthing complete with galvanized steel earthplate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically in a pit (earth pit of depth not less than 2.25 metre below ground level) with top edge of the earth platenot less than 1.50 metre below normal ground level surrounded from all sides by mixture of charcoal and common salt 15cm thick each layer and electrode connected to and includinggalvanized iron earth strip, 32 x 6 mm (earth lead) by means of bolts, nuts, check nuts and washers of galvanisedsteel protection pipe light grade 40mm dia and GI pipelight grade 20mm dia bore for watering, funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sq m) and frame including all excavation and earth work all as shown in electrical plate No 3 connected to earthing test point complete all as specified and as directed including testing on completion.Note : The unit rate includes for 40mm light grade protecton pipe and GI earth strip 32 x 6mm from top of earth plate upto 7.50 metre above ground level.The earth pit shall be constructed atleast 1.5m away from the top of earth electrode. 45 REFRIGERATION & AIR CONDITIONING:-Supply, install, testing and commissioning hi wall inverter split units indoor/outdoor with invertercompressor with adjust power depending on load complete with cordless remote control unit and with in built air ionizer and plasma filter for better indoor air quality with minimum 5 star ratingAs perBEE guidelines and ISEERValue not less than 3.90 for air conditionerof capacity 1.5 TR includingall specified and directed by Engr-in-Charge. 46 Supply, install, testing and commissioning hi wall inverter split units indoor/outdoor with invertercompressor with adjust power depending on load complete with cordless remote control unit and with in built air ionizer and plasma filter for better indoor air quality with minimum 5 star rating as perBEE guidelines and ISEERValue 3.95 for air conditionerof capacity 2 TR complete all specified and directed by Engr-in-Charge 47 Supply, fixing, jointing and testing copper tubing with nominal diameter1-1/4 inch ofthickness not less than 1.2mmfor liquid line to connect with out door unit complete all as specified and directed by Engr-in-Charge. 48 Supply, fixing jointing and testing copper tubing with nominal dia meter3/8 inch of minimum thickness not less 0.9mm including expanded polythene foam insulation for external insulation of suction line for connecting with outdoor condensing unitcomplete all as specified and directed by Engr-in-Charge. 49 Material and Labour for fabrication of base stand made from MS angle iron of size 50mmx50mm, 6mm thick including necessary nuts, bolts & washers for mounting of outdoor unit of 1.5/2 TR capacity Split AC including painting with two coats of metal paint over one coat synthetic enameled black paint complete all as specified and directed by Engr-in-Charge. 50 Supply and fix PVC non-metallic flexible pipe of size 20mm dia alongwith fixing accessories such as saddles, pipe hook etc, for draining out the water from indoor unit complete all as specified and as directed by Engr-in-Charge. 51 HAND DRIER AND SOAP DISPENSERSupply and fix automatic hand drier machine suitable for single phase supply 230 Volts, 50 Hzwith ABS plastic body complete all as specified and directed. 52 Supply and fix automatic soap dispenser , 220 V , 50 Hz complete all as specified and directed. 53 UPSSupply, installation, testing and commissioning of online UPS of 30 KVA with isolation transformer and static bypass switch, Authomatic transfer switch of capacity 100 Amps 4 Pole) alongwith required sealed maintenance free batteries and batteries (12V 100 AH-32 Nos)with stand for backup of 30 min totally enclosed, free standing type, dust, damp and vermin proof, interconnections, wiring from normal sources upto UPS complete as required.I/P Voltage 360 V - 480 VNominal frequency - 50 HzFrequency range for online operation 45-50 HzI/P current range - 36A - 29AO/P voltage 415 VO/P current - 42A 54 LIGHTNING PROTECTIONSupply & fix Special standing seam fixure Clamp for Air terminal on Metal Structure -Site specific all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No JICT54 or its equivalent in approved make. 55 Supply & fix Vertical Air Termination Solid aluminium with Base- 10 mm dia and 1000 mm long. Air Termination Base tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol, 3 mtr mast all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No JIAT02JIM04 or its equivalent in approved make. 56 Supply & fix 8 mm dia solid Aluminium Conductor for Down Conductor and tested as per IEC 62561- 2 conducted in the Govt. aggregated thirty party laboratory to meet the requirement of IS/ IEC 62305 all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No JIDC01 or its equivalent in approved make. 57 Supply & fix Aluminium conductor holding clamp suitable for fixing 8 mm Down Conductor, Conductor holder @ 1 meter distance should be tested as per IEC-62561-2 conditioning & Ageing test, conducted in the Govt. accredited thirty party laboratory to meet the requirement of IS/ IEC 62305 all as specified and directed by Engr-in-Charge. Make JEF Cat No JIDC01 or approved by E-in-C Branch/CE Southern Command.Make : TIRUMALA/JEF Cat No JICL07 or its equivalent in approved make. 58 Supply & fix Standing Seam clamp to hold 8 mm Al conductor at every 1m dist on the top roof without any drilling on roof, Installation can be made through simple fastening system ,mainly used for seaming sheet roof application tested as per IEC-62561-2 for conditioning & Ageing test & conducted in the Govt. accredited Third party laboratory to meet the requirements of IS/IEC 62305 all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No JICL49 or its equivalent in approved make. 59 Supply & fix Cross splicer should be ttested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEFCat No JISP02 or its equivalent in approved make. 60 Supply & fix Aluminium Straight Splicers for 8mm and 10 mm Conductor to meet the requirement of IS IEC 62305 tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No JISP01 or its equivalent in approved make. 61 Supply & fix Expansion Piece without connector to compensate the expansion and contraction of Solid Round Al. Conductor during temperature variations to be provided on conductors length over 20 meters to connect Solid Round Al. Conductor at both ends to meet the requirements of IS/IEC 62305 all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEFCat No JISP05 or its equivalent in approved make. 62 Supply & fix test link in order to disconnect the earth termination system for enabling measurements. SS Test Link To connectRound to Flatconductor all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No TL06 or its equivalent in approved make. 63 Supply & fix Earth Electrode Cu Bonded Steel Rod 14.2mm dia x 3000mm-(250Microns);Eco Friendly rust proof heavy duty weather proof Polyethylene Earth Pit Chamber with following dimensions :254 mm dia (top), 330 mm dia (bottom) & 260 mm (height).;14.2 / OD SS Clamp Both Side; Carbon based backfill compound - 25Kg all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No R14.CB1.SS01.E06 or its equivalent in approved make. 64 Suply & fix25 X 6 mm size GI strip from AL Conductor to the earth pit station and further the same strip shall be used for interconnecting all the earth pits below ground leve Zinc coating: 500 g/m square (Approx :70 micron coating) Should be tested and use exclusively for lightning protection ,earthing system and ring equipotential bonding all as specified and directed by Engr-in-ChargeMake : TIRUMALA/JEF Cat No DW16 or its equivalent in approved make. 65 Supply & fix Holder -GI for fixing 25x 6 mm GI Strip complete all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEFNo JICL08 or its equivalent in approved make. 66 MEDICAL GAS PIPE LINE SYSTEMSupply and installation / fixing, testing and commissioning of Copper pipe : Degreased seamless round coppertube confirming to EN13348:2008 with colour coding for :12mm X 0.7 mm laser Printing on every pipe. Make : Max / Flow/Raj/ janya/ RAJ 67 Supply and installation / fixing, testing and commissioning of Copper pipe : Degreased seamless round coppertube confirming to EN13348:2008 with colour coding for :15mm X 0.9 mm laser Printing on every pipe. Make : Max / Flow/Raj/ janya/ RAJ 68 Supply and installation / fixing, testing and commissioning of Copper pipe : Degreased seamless round coppertube confirming to EN13348:2008 with colour coding for :22x0.9mmlaser Printing on every pipe ) Make : Max / Flow/Raj/ janya/ RAJ 69 Supply and installation / fixing, testing and commissioning of Copper pipe : Degreased seamless round coppertube confirming to EN13348:2008 with colour coding for :28 x0.9mmlaser Printing on every pipe ) Make : Max / Flow/Raj/ janya/ RAJ 70 Supply and fix BS Standard type GEM 10 gasoutlet withprobefor oxygen complete all as specified and as directed. 71 Supply and fix Humidfier bottle forBPC flow meter complete all as specified and as directed. 72 Supply and fix Metal body BPC flow meter (0-15 ltrs ) adult complete all as specified and as directed. 73 Supply and fix BS Standard type GEM 10 gasoutlet withprobefor vacume complete all as specified and as directed. 74 Supply and fix 600 ML VACUUMEJar complete all as specified and as directed. 75 Supply and fix Vacummer regulator complete all as specified and as directed. 76 Supply and fix Zonal valve box completeset withisolationballvalve and gauge (Aluminium framewith MSBox for2services (15mmx 22mm) complete all as specified and as directed. 77 Supply and fix Microprocessor based line pressurealarmdigitaltypefor2 gas serivce(oxygen / vacumm) complete all as specified and as directed. 78 Material and labour for perforated powder coated cable tray of size 25x100x25 mm, thickness 2mm for holding of oxygen gas pipe line all as specified and directed. Make: Daspar / Super Steel Industry / SV metals Pvt Ltd 79 DEMOLITION OF EXISTING BUILDINS (E/M ITEMS)Taking down unserviceble submain wiring any size /any cap complete all as specified and as directed. 80 Taking down unserviceble DBs any size / any cap complete all as specified and as directed. 81 Taking down unservicebleMCB SP/SPN any size /any cap complete all as specified and as directed. 82 Taking up old earthing any size/any type complete all as specified and as directed. 83 Takingdown earth strip/wire any size/any type complete all as specified and as directed. 84 Dismantling and taking out carefully GI pipe 25mmdia including earth work/RCC and complete all as specified and directed Engr -in-Charge.
Contract Date: May 26, 2026 Contract Value : 11.48 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
37.
Drinking Water Supply and Sanitation #9962485 Technical Bid
Tender for Strengthening /Up-Gradation Of Infrastructure Of Hwmi Bikaner- Iec Lab And Mobilization Of Field Visits For Farmers, Repair Old Diggi And miscellaneous Items Etc, Hydrology And Hydrometeorology Lab, Gis And Remote Sensing Lab, Providing /Supplying And Installation Complete In All Aspects Of Wi-Fi System In Institute C Us Along With Adm. Block, Hostel Block, & Auditorium Complete, Providing /Supplying And Installation Complete In All Aspects Of Cameras For Security Purpose In Institute C Us Along With Adm. Block, Hostel Block, & Auditorium Complete, Digital Library And Publication. (Package-463) , Clearing Jungle Including Uprooting Of Rank Vegetation, Grass, Brush Wood, Trees And Saplings Of Girth Upto 30 Cm Measured At A Height Of 1 M Above Ground Level And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Areacleared. , Excavation Including Loading, Unloading, Disposal And Dressing Of Excavated Earth Within Initial Lead Of 50M And Lift Up To 1.5M Including Dressing Of Excavated Area And Dewatering Wherever Required Complete In Soft/Loose Soil , Hard Soil Mixed With Kankar / Boulders, Morrum , Add Extra Over Item No. 1 To 8 For Disposal Of Excavated Material Above Initial Lift Of 1.5M And For Every Additional Lift Of 1.5M Or Part There Of Including Loading And Un- Loading Wherever Required , Preparation And Dressing The Sub Grade Including Removal Of Irregularities Up To 7.5 Cm In Soil, Morrum Mixed With Pebbles, Small Boulders And Kankar & Murrum For Bed , Side Slope , Canal Lining With Hydraulic Compressed Pre-Cast Slab Of Cement Concrete M15 Tiles Of Size 300 X 150 X 40 Mm Laid Over 12 Mm (Av.) Thick Subgrade Cement Plaster In Cm (1:6) , 16 Mm Thick Jointing Sandwich Plaster In Cm 1:3 And 6 Mm Thick Jointing Mortar In Cement Mortar (1:3) Etc. Including Curing And All Leads& Lift Of All Construction Materials Complete In All Respect Bed , Side Slope , Supplying, Laying & Spreading Of Ldpe Film Of 250 Micron On Bed And Sides Including Jointing Etc. Complete As Per Specifications Including Cost Of Ldpe Film, Overlapping, Adhesive Tape Etc. With Transportation Charges Upto Work Site Complete. , Providing And Laying In Position Of Cement Concrete Nominal Mix (1:3:6) Including Leads Of All Construction Materials, Curing, Compaction And Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement : 3 Coarse Sand) And Making Good The Joints Excluding The Cost Of Centering, Shuttering And Reinforcement. Well Graded Crusher Broken Stone Aggregate Of Maximum Size Upto 20 Mm , Brick Masonry (Using Well Burnt Clay Bricks Of Size 230 X 110 X 70 Mm, Class Designation 75 As Per Specification) Up To Plinth Including All Leads Of All Construction Materials Including Curing Etc. Complete. In Cement Sand Mortar 1:6 , Add Extra If Well Burnt Clay Bricks (Size 230X110x70 Mm) Class Designation 100 As Per Specifications Are To Be Used , Plaster In Cement Sand Mortar 1:6 Including Racking Of Joints, Smooth Finishing & Curing Etc. Complete Including All Leads Of All Construction Materials , Of Thickness:12Mm , Providing And Fixing Concertina Coil Fencing With Required Dia 610 Mm (Having 15 Nos. Round Per 6 Metre Length) Up To 3M Height Of Wall With Existing Angle Iron Y Shaped Placed 2.4 M Or 3.00 M Apart And With 9 Horizontal R.B.T. Stud Tied With Gi Staples And Gi Clips To Retain Horizontal Including Necessary Bolts Or Gi Barbed Wire Tied To Angle Iron All Complete As Per Direction Of Engineer In Charge With Reinforced Barbed Tape Strength Of 165 Kg/Sq.Mm With Tape (0.52 Mm Thick) And Weight 43.478 Gm/Metre (Cost Of Ms Angle, Cement Concrete Block Shall Be Paid Extra) , Ms Angle Iron Y Shaped 1.34M Per Angle 50X50x6mm Placed 2.5M Apart@ 4.5Kg/M , Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering.M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size. , Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead With Cement Mortar 1 :4 ( 1 Cement : 4 Coarse Sand) , Distempering With 1St Quality Acrylic Washable Distemper (Ready Mixed) Of Approved Manufacturer And Of Required Shade And Colour Completeincluding All Scaffolding As Per Manufacturers Specification. Two Or More Coats On New Work Including Prepartion Of Base With Primer, Putty, Lippy Etc Complete In All Respect. , Renewal Of Old Putty Of Glass Panes (Length) , Renewing Glass Panes,With Putty And Nails Wherever Necessary , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Un- Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity 99.6 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Reinforced Cement Concrete / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray (With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have Its Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810. For Additional Technical Parameters Of Product. 70.0 Sq.Mm @3.5Core , 25.0 [email protected] , 10.0 Sq.Mm @4Core , Providing And Fixing In Position Collapsible Steel Shutters With Vertical M.S. Channels 20 X 10 X 2Mm And Bracket With Flat Iron Diagonals 20 X 5Mm. Size With Top And Bottom Rail Of T- Iron 40 X 40 X 6Mm. With 40Mm Dia Steel Pulleys/Ball Bearing Complete With Bolts, Nuts Locking Arrangements Inside And Outside Stoppers, Handles Etc. As Per Specification Including Applying A Priming Coat Of Approved Steel Primer. (To Be Measured And Paid As Per Outer Dimension). , P & F Bib Cock (Is : 8931 Mark), Superior Quality Of Approved Make: , (-Do-) Long Body, 15Mm Nominal Bore Weight Not Less Than 690 Gm , P & F Inlet Connection (Angle Valves) Superior Quality, Of Approved Make, For Wash Basin, Gyser Etc. , C.P. Inlet Connection 15Mm.Brass (Is : 8931 Marked) , P & F Wvc Wash Basin (Ist Quality Is:2556 Mark) Of Approved Make With C.I. Brackets Duly Painted 1 No. 15 Mm C.P. Pillar Cock (Is:8934 Mark) & 32 Mm C.P. Brass Waste Coupling Of Approved Make, P.V.C Waste Pipe With Pvc Nut 32 Mm Complete Including Cutting & Making Good The Wall : Size 580Mm X 450 Mm , P & F Premium Quality Low Level Flushing Cistern Of 10 Litres Capacity (Is:2556 Mark) Of Approved Make As Per Engineer-In- Charge With Complete Fittings C.I. Brackets Duly Painted, Brass Ball Cock With Ball, (Is:1703 Mark) Complete Including Cutting And Making Good The Wall : , Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy =125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @=300 V Ac And Auto Resetting Safety , Power Factor 0.95 Driver Efficiency 85% ,Thd(I) 10% Humidity 10% To 90% Rh Working Temp -5C To 45C . Driver Current 750Ma. The Luminaire Shall Be Bis Certified And Trade Mark Certified. Life Expectancy Equal Or More Than 50000 Burning Hrs With Minimum 70% Lumen Maintened , Cri 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products. , Led Street Light Fixture With Minimum Lumen Output 8700 Lm , Supply , Installation, Testing And Comissioning Of Inverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R- 410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And 50 Hz , Singlephase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work. , 1.5 Tr Iseer Not Less Then 4.6 , 2.0 Tr Iseer Not Less Then 4.6 , Providing And Fixing Stainless Steel Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.).(A)Grade 304 , Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150Mm Distance. , Providing And Fixing 1St Quality Standard White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades Glazed Tiles Confirming To Is : 13753 & Is :15622 Of Size 200Mm X 300Mm In Walls, Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Excluding The Cost Of Cement Plaster On Walls And Pillar). , P & F Jet Spray For Water Closet With C.P. Copper Tube Flange Of Approved Make.. As Per Pwd Bsr Ch No S-1 Code 1.59+ , Providing And Fixing Bath Shower Of Approved Quality/Make.C.P. Brass Of Heavy & Superior Quality 150Mm , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Concealed Work Including Cutting Chases And Making Good The Walls Etc.,)20Mm Nominal Size , Supply, Installation, Testing And Commissioning Of Mnre Approved Grid Tied Solar Panels With Inverter, Meter, Cable Etc. Suitable For Rooftop Installation As Well As Utility Scale Solar Power Projects With 25 Years Of Linear Generation Warranty. Work Includes Designing Of Solar Panel Area And Ms Frame And Foundation On Ground/Roof Of Pump House Or Cwr, Showing Arrangement Of Panel In Available Space, Installation Of Pv Module On Ms Frame As Per Approved Design And Drawings. Mounting Structure Shall Be Suitably Designed To Withstand Wind Velocity Up To 150Km/Hr. Grid Tie Transformer Less Inverters, Multiple Independent Mppts, Peak Efficiency Of 98%. Connect Up To Multiple Strings Pv Arrays, Easy & Fast Connection, Built-In String-Level Monitoring, Ip65 Protection Level, Wi-Fi / Internet Based Remote Monitoring With 5 Years Warranty. All Cabling Up To Panel And Metre, Earthing Etc. Required Accessories And Taxes Are Inclusive. The Work Shall Be Executed As Per Detailed Technical Specifications, Approved Drawing And Direction Of Engineer In Charge. Note: There Shall Be 5 Year Service Warranty For Panel, Inverter, Meter, Cable Etc. And Suitable Provision Shall Be Included In Tender Document.Solar Panels More Than 10 Kw And Up To 50 Kw At A Single Location. , Providing And Fixing Wall Panelling Using Soft Wood Frame Of Size 50X25mm @600 Mm C/C In Both Directions Duly Treated With Anti-Termite Treatment Making Grooves Painting Of Grooves Specification And Drawing Using : Isi 9 Mm Teak Ply One Side Bwr , Providing And Fixing Nigeria / Ghana /Ivory Coast Teak Wood Grade-I Mouldings And Beadings In Droos And Windows Size :-50X20 Mm Total , Providing And Fixing Wooden Moulded Corner Beading Of Triangular Shape To The Junction Of Panelling Etc. With Iron Screws, Plugs And Priming Coat On Unexposed Surface Etc. Complete 2Nd Class Teak Wood. 50X50mm (Base And Height) For Corners Considered 1/5 Th Of Item 2 , Providing And Applying Malamine Polish On Teak Wood Work Of Approved Brand And Manufacture To Give An Even Shade With Two Or More Coats By Compressor Including Sand Papering, Wood Filler Coat Etc Complete In All Respect. New Work Same As Per Item No 1 , Providing And Fixing 15 Mm Thick Densified Tegular Edged Eco Friendly Light Weight Calcium Silicate False Ceiling Tiles Of Approved Texture As Per Direction Of Engineer-In-Charge Of Size 595 X 595 Mm In True Horizontal Level Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections (Galvanizing @120 Grams Per Sqm) Consisting Of Main „T‟ Runner Suitably Spaced At Joints To Get Required Length And Size Of 24X38mm Made From 0.33 Mm Thick (Minimum) Sheet, 1200Mm Centre To Centre, And Cross „T‟ Of Size 24X32mm Made Out Of 0.33Mm (Minimum) Sheet, 1200Mm Long Spaced Between Main „T‟ At 600Mm Centre To Centre To Form A Grid Of 1200X600mm And Secondary Cross ‟T‟ Of Length 600Mm And Size 24X32mm Made Out Of 0.33 Mm Thick (Minimum) Sheet To Be Interlocked At Middle Of The 1200X600mm Panel To Form Grid Of Size 600X600mm Resting......On Periphery Walls/Partitions On A Perimeter Wall Angle Precoated Steel Of Size (24X24x3000mm Made Of 0.40Mm Thick (Minimum) Sheet With The Help Of Rawl Plugs At 450Mm Centre To Centre With 25Mm Long Dry Wall Screws @ 230Mm Interval And Laying 15Mm Thick Densified Edged Calcium Silicate Ceiling Tiles Of Approved Texture In The Grid Including Cutting /Making Opening For Services Like Diffusers, Grills, Light Fitting, Fixtures, Smoke Detectors Etc., Wherever Required, Main „T‟ Runners To Be Suspended From Ceiling Using 50 Mm Long M 6 Dash Fasteners, 6Mm G.I. Fully Threaded Rods With Galvnised Steel L Cleat Level Adjusters Of Size 80X25x2mm, Spaced At 1200Mm Centre To Centre Long Main „T‟ Bottom Exposed With 24Mm Of All T-Sections Shall Be Pre-Painted With Polyster Baked Paint, For All Heights, As Per Specifications, Drawing And As Directed By Engineer-In-Charge. Note :- Only Calcium Silicate False Ceiling Area Will Be Measured From Wall To Wall. No Deduction Shall Be Made For Exposed Frames/Opening (Cut Outs)Having Area Less Than 0.30 Sqm. The Calcium Silicate Ceiling Tiles Shall Have Nrc. , Desk Top Computer Mid Highlevel Configuration (Intel I7 With 14Th Generation (Estimated Cost Rs. 90,000 Considering Pre-Installed Genuinewindows 11 Profesional, 16 Gb Ram And 1 Tb Storage) , Ups 1Kva , Supply Of Computer Table Of Modular Nature Having All The Necessary Arrangement For Keyboard, Cpu, Ups, Printer And Wire Manager Table Top : The Table Top Of Size 900 X 600Mm(Wxd) Would Be Made Out Of Post Formed On 25 Mm Thick Particle Board With 0.7Mm Thick Carvica Sheet In Half Round Post Formed Finish On The Front And Rear Side, Matching Color Compensating Laminate Fixed On The Bottom Side. Other Two Sides Are Edge Banded And Duly Sealed With 1.5 Mm Thick Pvc Edge Banding Of Matching Color With High Pressure Through Feed Machine. Keyboard Below The Table Top The Keyboard Pull Out Tray Having Sliding Arrangement Fixed On Side Supporting Legs With 450Mm G.I. Telescopic Channel. Keyboard Of Size 750 X 450 Made Out Of 18 Mm Thick Particle Board Laminate With 0.7Mm Thick Laminate Sheet Having All Four Sides Flat Edge Banded And Duly Sealed With 1.5 Mm Thick Pvc Edge Banding Of Matching Color With High Pressure Through Feed Machine. Side Support :Two Supporting Side Leg Of Size 600 750Mm(Wxh) Made Out Of Post Formed On 18 Mm Thick Particle Board With 0.7Mm Thick Carvica Sheet In Half Round Post Formed Finish On Two Sides And Other Two Sides Are Edge Banded And Sealed With Cpu, Ups & Printer Places Table Having The Provision For Cpu Of Size 300 X 600 X 600Mm(Wxdxh) Below The Table Top On The Right Side Of Table Adjoining To This On Left Side Below The Table The Provision For Ups Of Size 450 X 600 X 250Mm (Wxdxh) And Above This The Provision For The Printer And Stationary Having Overall Dimension Of 450 X 600 X 300Mm(Wxdxh). All This Is Made Out Of 18 Mm Thick Particle Board Laminate With 0.7Mm Thick Laminate Sheet Having All Four Sides Flat Edge Banded And Duly Sealed With 1.5 Mm Thick Pvc Edge Banding Of Matching Color With High Pressure Through Feed Machine. All The Parts Of The Table Are Duly Fixed With Mini Fix Dowel System With Each Other Having Matching Drilled Holes To Be Made On Cnc Multi Hole Boring Machine For Proper Matching And Alignment Of The Different Part Of The Table, 4Nos. Of Self Adjusting Level Screw Of Size 45 X 6Mm Are Provide At The Bottom Of The Both Legs For The Proper Leveling Of The Table. , Providing And Fixing Wooden Moulded Corner Beading Of Triangular Shape To The Junction Of Panelling Etc. With Iron Screws, Plugs And Priming Coat On Unexposed Surface Etc. Complete 2Nd Class Teak Wood. 50X50mm (Base And Height) For Corners Considered 1/5 Th Of Item 2 , Automatic Weather Station Under Hydro Metrology Lab. With Installation. , Nvr 32 Channel 4K , Poe Switch 8 Port Full Giga(10/100/1000) , Poe Switch 24 Port Full Giga(10/100/1000) , Hard Disk 10Tb , Bullet Camera 5Mp 6Mm , Bullet / Dom Camera 5 Mp , Cat- 6 Outdoor Cable(300 Mtr.) , 4U Poe Rack , 8U Network Rack With Pdu, Self Tray , Rj-45 Moduler Plug , Optic Fiber Cable Outdoor , Sfp Fiber Convertor , Sfp Moduler , Spike Power , Bird Spike , Pvc Box For Camera , Pole Mount Brackets , U Clip For Wire Fixing , Ups 600Va , Hdmi Switch 4 Port 4K , Usb Extension Cable , Wireless Mouse , Led Tv 65 Full Hd , Installation & Service Charge , Earth Work In Excavation In Foundation, Trenches Or Drain (Not Exceeding 1.50 M In Width) Including Dressing Of Sides And Ramming Of Bottom, Lift Up To 1.5 M Including Getting Out The Excavated Soil And Disposals Of Surplus Excavated Soil As Directed With A Lead In A 50 M, All Kind Of Soil. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth Side Of Foundation Etc In Layer Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering Including Lead Up To 50M And Lift Up To 1.5M , P & L In Position Cement Concrete Including Curing Compaction Etc. Complete Using Stone Aggregate 40 Mm Nominal Size In Foundation Plinth, Excluding The Cost Of Shuttering Using 1 Cement:4 Sand:8 Aggregate .(C)40Mm , Brick Masonry In Foundation And Plinth With Brick Of Cd 100 In Cement Sand Mortar 1:5, Add Extra Over Item No.6 (A)For Using Brick Class Designation 100 Instend Of Class Designation 75 , Brick Masonry For Super Structure With Brick Of Cd 100 In Cement Sand Mortar 1:5, Add Extra Over Item No.6 (A)For Using Brick Class Designation 100 Instend Of Class Designation 75,(B) Extra For Brick Work In Superstructure Above Plinth Level For Every 5 M And Part Thereof , Providing And Fixing Unplasticized Poly Vinyl Chloride (Upvc) Swr Pipes Type B For Sciland Waste Discharge System (Is:13592 : 1992 Marked) Of Approved Quality /Make 110 Mm Dia , Providing And Fixing Unplasticized Poly Vinyl Chloride (Upvc) Swr Pipes Fittings Type B For Sciland Waste Discharge System (Is:13592 : 1992 Marked) Of Approved Quality /Make Bend 87.5 Dg. 110Mm Dia , Cement Plaster With Cement Sand Mortar 1:5 Including Racking Of Joints, Smooth Finishing And Curing Etc. Complete Including All Leads Of All Materials Of Thickness 12 Mm Thick In 1 Coats. , Cement Concrete Flooring Grade 1:2:4 (1 Cement, 2 Course Sand, 4Graded Stone Aggregate) Rounded Off Edge Etc. But Excluding The Cost Of Nosing Etc. Complete, 40 Mm Thick With 20 Mm Nominal Size Aggregate. , Construction Of Soakage Well In All Type Of Soil With 300 Mm Thick Dry Masonry, Top And Bottom 300 Mm Course In Cm 1:6, 80Mm Thick Stone Slab, Jointing Of Slab In Cm 1 : 3, Ralthal, Kharanja, 40 Mm Thick M-15 Grade cement concrete Flooring , Earthwork Complete As Per Approved Drawing Including Disposal Of Earth Within A Lead Of 50 Mtr.: Size 300 Cm. Dia Outside & 300 Cm. Depth , Providing And Fixing Welded Mesh/Expanded Metal Mesh In Frame Work, Flat Iron Beading 20X3mm Including Top Cross Laps Inside And Out Sides Welding, Iron Bolts, Crews, Clips Etc. Complete (Excluding Frame Work) Of Size. Welded Mesh 25Mmx25mmx2.10Mm , Providing And Fixing T-Iron Frames For Doors Window And Ventilators Of Mild Steel Tee-Sections, Joints Mitered And Welded With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Blocks 15 X 10 X 10 Cm Of 1:3:6 (1 Cement :3 Course Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) Or With Wooden Plug And Screw Or Rawl Plugs And Screws Of With Fixing Clips Or With Bolts And Nuts As Require Including Fixing Of Necessary But Hinges And Screw And Applying A Priming Coat Of Approved Steel Primer. , Providing And Fixing M.S. Sheet 1Mm Thick Single Leaf Door Shutter In Angle Iron Frame 35X35x5mm Suitabilly Diagonally Braced With 25X3mm Flat Iron Above And Below Lock Rail Of Size 50X5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-Corrosive Red Oxide Primer Paint (A) Single Leaf Shutters , (B)Add Extra For Double Leaf Shutters. , White Washing With Lime To Give An Even Shade Including All Scaffolding.New Work Three Or More Coats. , Painting With Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade. : Two Or More Coats On New Work. , P & F Indian Type White Glazed Vitreous China Ist Quality Wc Orissa Pan (Is : 2556 Mark) With 100 Mm Vitreous China P Or S Trap Including Cutting And Making Good The Wall And Floor/ Size 580 X 440 Mm , P & F G I Pipes (External Works) With G I Fitting ( Is: 1239 Mark) Including Trenching & Refilling Earth Etc. 15 Mm Dia Nominal Bore Class - B , P & F G.I. Pipes (External Work) With G.I. Fittings Excluding Union (Is : 1239 Mark) Including Trenching & Refilling Earth Etc.: 25 Mm Dia Nominal Bore Class-B , P & F Bib Cock ( Is:8931 Mark), Superior Quality Of Approved Make. ( Brass 400 Gm, 15 Mm Nominal Bore) , P & F Storage Tank ( Is : 12701 Marked Indicated The Bis License No), Approved Make With Cover, 25 Mm Dia Im Long G I Over Flow Pipe & 25 Cm Long Wash Out Pipe With Plug & Socket, Including Making Connection Etc. Complete Of Approved Design. ( 500 Ltrs) , P & F Flush Cock/Flush Valve ( Is:9758 Mark) For W/C Of Approved Quality Make.Cp Brass Half Turn Exposed 25 Mm Nominal Bore. , Providing And Laying And Jointing Glazed S W Pipe Grade A ( Is 651 Marked) Of Approved Make With Spun Yarn And Stiff Mixer Of Cement Mortar 1:1 Excavation And Refilling Of Earth In All Type Of Soil Upto 1.20 Mtr Depth S W Fitting Including Testing Of Joints Etc Complete. 100 Mm Dia , Providing & Laying cement concrete 1:5:10 (Stone Aggregate 40Mm Nominal Size) All Around S.W. Pipe Including 15 Cm. Thick Bed Concrete (Width W= Diameter Of Pipe In Cm+30 Cm.)( Excluding Cost Of Pipe) 100Mm Dia S.W. Pipe. , Providing And Laying Four Courses Water Proofing Treatment With Bitumen Felt Over Roofs Consisting Of First And Third Courses Of Blown Bitumen 85/25 Or 90/15 Conforming To Is : 702 Applied Hot 1.45Kg. Per Square Meter Of Area For Each Course, Second Course Of Roofing Felt Type 3 Grade -I (Hessian Based Self Finished Bitumen Felt )And Fourth And Final Course Of Stone Grit 6Mm And Down Size Of Pea Sized Gravel Spread At 6Cubes Diameter Per Square Meter Including Preparation Of Surface, But Excluding Grading, Complete With Bitumen Felt (Hessian Base) Type 3 Grade - I Conforming To : 1322.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
38.
Defence #9929205 AOC
Tender For Augmentation Of Power Supply At Naval Area Visakhapatnam.; 1 Schedule A Part – I to Schedule A Part – VII:NOTE: Schedule A Part – I to Part –VII are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only 2 Lumpsum price worked out by the contractor for BUILDINGS & STRUCTURES,as listed in Schedule A Part – I 3 Lumpsum price worked out by the contractor for SITE CLEARANCE / AREA DEVELOPMENT/EARTH WORK/EXCAVATION,as listed in Schedule A Part – II 4 Lumpsum price worked out by the contractor for INTERNAL ELECTRIFICATION, as listed in Schedule A Part – III 5 Lumpsum price worked out by the contractor for INTERNAL WATER SUPPLY, as listed in Schedule A Part – IV 6 Lumpsum price worked out by the contractor for SEWAGE DISPOSAL,as listed in Schedule A Part – V 7 Lumpsum price worked out by the contractor for EXTERNAL ELECTRIFICATION, as listed in Schedule A Part – VI 8 Lumpsum price worked out by the contractor for LIGHTENING PROTECTION ,as listed in Schedule A Part – VII 9 Schedule A Part - VIII: (Miscellaneous Items) ( Internal Electrification, Internal water supply, External Electrification, Site clearance & Area development, Lightening Protection and AC & Ref) 10 Internal Electrification 11 M&L for Ponit wiring with 1.5 sqmmPVC insulated and unsheathed copper conductorcable multistranded 1100 Volts grade, FRLS, ISI marked drawn through and inculding non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marked, concealed to wall or surface mounted on pillars/columns including provn of box type switchboard consisting of pre fabricated pressed steel terminal box of suitable size made out of 1.2 mm thick sheets,for mounting modular brackets,with and including modular brackets and switch plates as required at site for fixing modular type switches, sockets etc inculding one run of 1.5 sqmm PVC insulated unsheathed copper cable for earth continuity green in colour, connected to earth duly complete all as specified and directed forOne light/ exhaust fan/ fanpoint controlled by one switch :-Note: (a) The PVC conduit shall be concealed and switch boards shall be flush to wall. (b) On columns/ pillars the box type switchboards surface mounted with necessary PVC conduit upto ceiling/nearest junction tapping shall be surface type conduitand quoted rate deemed to be inclusive for the same.(c) The quoted rate inclsuive necessary modules any type as per requirement incl all accessories complete 12 All as per item No. 10 abovebut one light point controlled by two Nos of two way switch complete all as specefied and directed. 13 All as per item No.10 above but One3 pin socket outlet 05 amps socket on independent board with 1.5 sqmm FRLS PVC wire for phase and neutral and one run of 1.5 sqmm copper cable green in colourfor earth continuty conductor complete all as specefied and directed. 14 All as per item No.10 above but One3 pin socket outlet 15 amps socket on independent board with 2.5 sqmm FRLS PVC wire for phase and neutral and one run of 2.5 sqmm copper cable green in colourfor earth continuty conductor complete all as specefied and directed. 15 All as per item No. 10 above but for one geycer/AC point with 4.0 sqmm FRLS PVC wire for phase and neutral and one run of 4 sqmm copper cable green in colourfor earth continuty conductor complete all as specefied and directed. 16 S&Fexhaust fan, steel body AC single Phase. 230 V of size 450mm sweep with, blades, and frame and louvers fixed on wall making opening, fixing and making good the distrubed surfaces etccomplete with and inclussive of making necessary electric connection from ceiling rose to fan through 1 sqmm twin core flexible wire all as spcified and as directed. 17 S&FLED tube light fitting, batten type,poly carbonate body, 20Watt fitting with all accessories, internally prewired and connecting up with with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. 18 S&FLED light fitting, batten type,suspended LED aluminium profile lights cool white 36 watt length 1200mm including all connections, hanging strings complete all as specified and directed. 19 S&FLED bay light fitting 70 Watt 230V AC indoor type with thermal management in multiple optics and industrial type and corrosion resistant complete with driver and lamp complete all as specified and directed. 20 S&FLED flood light fitting 210 Watt 230V AC out door type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. 21 S&F LED bldg Security light fitting 35 Watt, 230AC out door type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 ptoction complete all accessories including 1.5sqmm weather proof 3 core FRLS grade copper conductor to fitting including 32mm dia medium grade1.5 m long GI pipe for fixing of street lights, bend to shape for fixing on wall/pole withsuitable MS brackets nuts and bolts etccompelte all as specified and as directred. 22 M&L for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall/roof, and PVC wire of size 2x2.5 sqmm for phase and neutral duly colour coded and 1x2.5 sqmm for earth continuity conductor green in colour complete all as specified and as directed.( for SPN DB to board and submain wiring of building security light)Note :(i) Two run of 2.5 Sqmm + one run of 2.5 Sqmm as a earth wire cable + one run of PVC conduitshall be measured as an one Unit. 23 M&L for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall/roof, and PVC wire of size 2x4 sqmm for phase and neutral duly colour coded and 1x4 sqmm for earth continuity conductor green in colour complete all as specified and as directed.Note :(i) Two run of 4 Sqmm + one run of 4 Sqmm as a earth wire cable + one run of PVC conduitshall be measured as an one Unit. 24 M&L for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall/roof, and PVC wire of size 4x10 sqmm for phase and neutral duly colour coded and 1x10 sqmm for earth continuity conductor green in colour complete all as specified and as directed.Note :(i) four run of 10 Sqmm + one run of 10 Sqmm as a earth wire cable + one run of PVC conduitshall be measured as an one Unit. 25 S&F VTPN MCCB DB 4 way 12 outgoing having powder coated sheet steel enclosure fitted with bus bar, DIN channel & neutral link & earth link complete all as specefied and directed. 26 S&F TPN DB 4 way 12 outgoing having powder coated sheet steel enclosure double door fitted with bus bar, DIN channel & neutral link & earth link complete all as specefied and directed. 27 M&L for earthing complete with GI steel plate electrode 600x600x6 mm, burried directly in ground (earth pit not less than 2.25 m deep below ground level)with top edge of the plate not less than 1.5 m below normal groundlevel, connected to GI wire 4 mm dia (upto 7.5M in length from earth plate) by means of bolts, nuts, check nuts and washers of GI all as shown in electrical plate No-3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipelight grade for watering pipe and 32 mm bore GI light grade for earth lead protection pipe connected upto DBs, and suitable CI top cover with handle, funnel, strainer,charcoal, salt and testing on completion all as specified and directed. Note- Rate quoted deemed to be include excavation and earth work in any type of soil with PCC workcomplete all as specefied and directed.Note: GI earth wire upto 7.5 m shall be deemed to be included in the quoted lumpsum and beyond 7.5 m shall be measured and paid separately under relavent item. 28 Internal Water Supply 29 S&F Bib taps two way, cast copper alloy fancy typechromium plated with crutch or butterfly handle, screwed down for size of15 mm inner dia, suitable fo 16 mm outer dia CPVC pipes complete all as specified and as directed. Make:- Jaquar cat No. OPP-15041PM or equivalent 30 SITE CLEARANCE / AREA DEVELOPMENT/EARTH WORK/EXCAVATION 31 M&L for cleaning jungle incl uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm and removal of rubbish upto a distance of 50 m outside the pheiphery of the area cleared all as specified and as directed. 32 External Electrification 33 Supply, Installation, Testing and Commissioning of Copper wound Power transformer step down outdoor type 132/33 KV, capacity16 MVA(suitable for 10/16MVA cooling), ONAN/ONAF, Vector group Star/star (YNyn0) with on load tap changing gear (+) 5% to (-)15% in steps of 1.25% on HV side, with terminal arrangement of HV Outdoor Bushings/LV Bushing and all standard accessories as per IS 2026 and as specified in PS, including first fill of oil complete comprising the following accessories:-a)Conservator Tankb) Pressure Relief Devicec) Buchholz Relay & Oil Surge Relayd) NCT on EHV and HV sidee) Oil Temperature Indicator (OTI)f) Winding Temperature Indicator (WTI)g) Oil Sealingh) Breatherj) Aircell in conservator tankk) Radiators and control valvesl) Each radiator tank shall have its own cooling fans, shut off valves at the top and bottomm) motor operated OLTC shall be n) On load tap changing with RTCC panelo) Marshalling boxp) Thermosphyn filter 34 q) Terminal Connectorsr) Direct solid earthing both HV side and LV sides) Name Plate (Rating, Diagram and Valve Plates)t) Metallic enclosed NGR as per OEMu) NIFPS to be installed by OEMTransformer rating plate shall contain the information as given in IS-2026 (Part-I).Makes: Bharat Bijlee/Crompton Greaves / Schneider / Siemens 35 Note : a) PCC foundation and mounting rails, all civil work, etc and general works which are required as per site/technically required to achieve optimum efficency of the transformer are to be supplied by the contractor for which rate is deemed to be included in the unit rate quoted.b)Size of plinth, PCC, Rail size etc shall be as per OEM recommendation.c) Technical drgs of the transformer alongwith NIFPS submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the Transformer to be inspected by the rep of accepting officer at various stages at Factory premises as per IS before despatch.d) pre-commissioning inspection of Transformer shall be carried out by Senior Electrical Inspector / Electrical Inspector.e) Manufacturer shall possess NABL accredited test lab for electrical testing(Routine test, type test and special test) 36 f)Full Type Test Reports of at least the followings must be submitted: -1. 132/33 kV Power Transformer for same capacity or higher2. Tap Changer3. Buchholz Relay4. Pressure Relief valve5. Oil Surge Relay6. Temperature rise test7. Impulse test 8. Load and No load loss 37 Supply, install, test and commission lightning arrestor single pole made of polymer , heavy duty station class, gapless, zinc oxide type (non linear) fitted with pressure relief device, arc diverting ports, grading/corona rings, discharge counter with ammeter, mounting insulator complete all as specified and as per IS 3070 (Part I) and with following parameters:- Nominal system voltage : 132 KVNormal discharge current rating : 10 KA .Note- The cost of Galvanised Iron lattice structure including foundation (as Per OEM) is deemed to be included in the Quoted rate 38 Supply, Installation, Testing and Commissioning of cable XLPE insulated, armoured, 132 KV grade (E) copper conductor UG cable, laid in trenches/on structures/in cable duct horizontally or in tier formation as per site condition complete all as per IS specifications of size. 1 C x 630 sqmm. The cable shall be of EHV grade single core, armoured stranded compacted circular Copper conductor of cross section 630 sq.mm, core screening by a layer of semiconducting tape followed by a layer of semiconducting compound, cross linked polyethylene (XLPE) dry cured insulation, insulation screening with semiconducting compound extruded directly over the insulation, longitudinal sealing by a layer of non woven tape with water swellable absorbent over insulation screen, followed by radial sealing of corrugated & seamless or seam welded aluminum with asphalt coating & overall PE sheathed & graphite coated/semi conducting layer and conforming to the technical particulars of specification.IS 7098 part 3 shall be followed for manufacturing of cable along with technical specification. Makes: Universal/ KEI /RPG/CCI.Note- Technical details of the cable submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the cable to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. 39 Supply, lay, connect, test and commission multi core copper conductor cables, PVC insulated, LT 1100 volts grade GI strip/wire armoured in ducts/on structuresincluding clamps, terminations on both ends with glands and connecting up to the equipment all as specified and of following sizes:- 40 4 core 1.5 sqmm 41 4 core 2.5 sqmm 42 6 core 2.5 sqmm 43 6 core 4 sqmm 44 Supply and fix GI cable tray perforated on walls/MS angle iron supportsof depth 100mm following widths including bends, coupler plates complete all as specified.Note: Angle iron used for fixing cable trays will be measued and paid separately. 45 200 mm width 46 300 mm width 47 Material and labour for provision of earthmat laid in trenches/ ducts/ walls made of following sizes of GI strips including jointing by means of brazing complete all as specified :- 48 GI 100 x 10 mm 49 GI 75 x 10 mm 50 GI 50 x 6 mm 51 GI 32 x 6 mm 52 Supply and fix earth strip following sizes laid in trench/ floor/ walls including jointing by means of brazing complete all as specified :- 53 100 x 10 mm copper strip 54 50 x 6 mm copper strip 55 32 x 6 mm copper strip 56 Supply, installing, testing and commissioning of CPRI approved LT panel board, cubical indoor type, fabricated out of 2.00 mm thick CRCA sheet with angle iron frame made of 50 x 50 x 6mm at vertical corners & medium channel at base of panel board floor mounted, dust and vermin proof, with busbar 200 Amps suitable for voltage 415 V 3 phase 4 wire weather proof, with separate hinge door for each compartment with locking arrangement, with back door common openable (screwed), groutedin PCC 1:2:4 complete incl painting the steel surfaces with two coats of zinc chromate primer & two coats of epxoy paint suitable for installation in coastal areas and incl of suitable size aluminium busbar (TPN), suitable cable glands, LED Indicating lamps and incl provn of the following:- 57 (i) 4 Pole MCCB 25 KA 100 A - 1 Nos (I/C)(ii) 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA - 03 No (iii) 4 Pole MCCB 40 Amp, 50 Hz, 415 V with rupturing capacity 25 KA - 02 No (iv) 4 Pole MCCB 25Amp, 50 Hz, 415 V with rupturing capacity 25 KA - 02 No (v) Digital voltmeter with selector switch - 1 No (vi) Digital ammeter with CTs & selector switch - 1 No (vii) LED indicating lamps - 8 sets (3 lamps/set) 58 Supply and lay in trenches HDPE pipe Double wall corrugated 200 mm dia with integral socketsfor cable protection including necessary collars, earth work and sealing at both ends with bitumen compound complete all as specified. 59 Supply, lay, connect, test and commission cable LT 1100 volts heavy duty XLPE insulated armoured aluminium conductors, in trenches/ ducts on angle iron supports including glanding, crimping and connecting up complete all as specified and of following sizes:- 60 3.5 Core x 95 sqmm 61 4 Core x 25 sqmm 62 Supply, Installation, Testing and Commissioning Earthing complete with Galvanised Iron plate electrode 600x600x6 mm thick buried directly in ground(earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to GI earth strip 32 x 6 mm by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 3 of SSR part I including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel with 15 mm dia medium grade for watering and for protection of earth electrode 40 mm dia light grade GI pipe all as specified and directed and tested on completion. 63 Supply, Installation, Testing and Commissioning Earthing complete with copper earth plate electrode 600x600x3 mm thick buried directly in ground(earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to copper earth strip 25 x 3 mm by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 3 of SSR part I including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel with 15 mm dia medium grade for watering and for protection of earth electrode 32 mm dia light grade GI pipe all as specified and directed and tested on completion. 64 Boring of holes under road, pavement, hard standing by trenches by trenchless technologyas per site conditions using ultra sound technique and necessary machinery complete all as specified 65 depth of trench varying between 2 to 4 meters 66 depth of trench varying between 4 to 7 meters 67 Supply, Installation, Testing and commissioning ofindoor, metal enclosed corrosion proof aluminium alloy gas insulated switchgear 145 KV 3Phase 50 HZ, 2500 Amps, Three phase encapsulated consisting of2 nos outgoing transformer bay in either side of the existing GIS (Siemens) including installation tools, spares, refill kits all as specified. Makes: ABB/CG/GE/SIEMENS 68 Each Transformer feeder bay consists of the following: 2Nosa) Circuit breaker SF6 insulated 145 KV 2500 A 3 pole with short circuit current with stand capacity of 40 KA for 3 sec - 1 No.b) Disconnector cum earthing switch SF6 insulated, 145 KV 2500 A 3 pole motor operated - 2 sets.1 set on Bus side and 1 set on line side.c) Fast acting earth switch SF6 insulated 145 KV motor operated - 1 sets. d) Current transformer 145 KV 300-150/5+5+5 with Core 1:class 0.2, 15 VA , Core 2 : 5P20, Core 3 : PS class, 15 VA respectively - 1 Set (Three Nos).e) Three phase Voltage transformer 0.2 class accuracy, 10 VA burden,145 KV, 132 KV/√3/110V/√3 - 1 set.f) Lightning arrestor gapless type metal zinc oxide type 120 KV rms 10 KA including discharge counter and leakage current meter.g) Bus bars 145 KV 2500 Amps 3Ø - required as per scheme.h) Cable end box suitable for 132 KV system - 1 No.j) Local control panel- 1 No. 69 Note : The GIS system offered by the bidder shall be designed, manufactured, assembled and tested in accordance with the IEC 62271-203 for switch gear and other relevant IEC andfor balance materials as mentioned in PS. The GIS Outgoing bays are to be installed with the existing GIS extension (Siemens Make ) interface in either sides of the setup. Bidder has to supply the following items along with GIS system and costis deemed to be included in GIS system. Civil foundation / mounting rails, all civil work, etc and general works which if required as per site/technically required to achieve optimum efficency are to be supplied by the contractor for which rate is deemed to be included in the unit rate quoted. Erection & commissioing shall be under OEM recommendation and supervision. The earth connection from GIS euipment to earth grid/matt as per OEM recomendation and the cost of same is deemed to be included in the unit price. Technical drgs of the GIS module submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the GIS module to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of GIS module shall be carried out by Senior Electrical Inspector / Electrical Inspector. 70 a) Local control cubicles.b) Gas handling equipment for draining and refilling of each compartment of GIS including filtration and purification equipment and vacuum pump. c) SF6 gas sufficient for first filling of entire switch gear including usual losses during commissioning.d)1 Bottles (40 Kg each) of SF6 gas in non returnable vessels. e)Gas leakage detectors.f) Gas Purity Tester for air content and moisture content in SF6 gas. g)Special tool and tackles for erection operation and maintenance of GIS h)Mandatory spares and tools ( Aux contact ( for CB, Busbar disconnector), Motor for CB drive (DS-ES drive), Bursting Disc, Adsorber, Density Monitor for CB, Tripping coil, Closing Coil. - 01 set Each.(i) Bay control unit. 71 Supply, Installation, Testing and Commissioning of control and relay simplex type panel with front swing & front perplex glass door RAL7035 natural IP 32 ventilation for 132/33 KV transformers protection consisting of the following: 72 a) Numerical Transformer Differential Protection Relay Make- ABB/Siemens – 1nob) Numerical Backup Protection Relay of Make - ABB/Siemens – 1noc) Tri Vector Meter - Secure make Premier 300 or Equivalent- with ABT & RS485 (modbus) port, RJ 45 port Accuracy class 0.2S- 2nod) Auxiliary Relay - with self-reset contacts. Operating time<20ms. (4 Contacts) of Make ABB/Siemens – 5nose) DC/ACSupply Supervision-200ms 73 Supply, Installation, Testing and Commissioning of 145KV 630A 40KAOil filled outdoor termination with composite insulator, solid rod connector bolt and support insulators for cables with XLPE insulation. The termination base plate and the cables metallic sheath shall be electrically insulated from the supporting structure by means of self-supporting stand-off insulators or any other self-supporting means designed to withstand both mechanical and electrical stresses in services. The stress cone shall inhibit possible mechanical stress and deformation of the cable insulation surface during operation and also shall be capable of accommodating minor radial and longitudinal movement without determent to the dielectric stress in the insulation shield. The termination shall be within polymeric or porcelain hollow insulator in brown or grey colour as perstandard practice of manufacturing in addition upon, arcing horn and shield ring shall have to be supplied wherever required. The termination shall be filled with an insulating compound up to a level where the electric field is substantially reduced and shall be offered. Oil filled termination should have silicon oil as di-electric medium. Silicon oil should not be subject to any heating at site prior to filling. The outdoor terminal should be suitable for very heavily polluted atmospheric conditions with total creepage distance of 31 mm/ kV and protected creepage distance of not more than 50% of the total Creepage distance. The cable end terminals for terminating the cables shall be fully compatible with the cables to be supplied. Civil foundation / Supporting Strcuture etc and general works which are required as per site/technically required to achieve optimum efficency are to be supplied by the contractor for which rate is deemed to be included in the unit rate quoted. 74 Supply, Installation, Testing and Commissioning of 145kV Dry type GIS termination suitable for XLPE 132 KV IC x 630 sqmm including necessary accessories , fixtures and fittings of complete installation etc complete all a specified and directed.Indoor Termination at GIS SF6 Housing It shall be dry type without insulating oil. There shall be mechanical devices to maintain the interface pressure if requires. It shall be based on the EPR (Ethylene-Propylene Rubber)- based or silicon based stress relief cone. Termination shall be dry type without insulating oil. Stress relief cone and mechanical devices shall be designed to fit with controlled interference over the cable insulation and shall follow the cables diameter variations still guaranteeing under any service condition a sufficient positive pressure to control the electric field concentration. Plug-in type leading conductors shall be supplied though at the time of detailed engineering confirmation shall be given for selection of normal type, blind type or plug-in type. Design and scope of delivery shall be fully complying with IEC-60859, IEC-62271-209 and possibly adjusted the various needs of project. The main insulation components shall be fully examined and tested in the factory.For cable Termination purpose only certified (certification from cable accessories manufacturer ) personnel shall be employed. Make: Raychem or Equivalent 75 Supply, Installation, testing & commissioning ofHT 33KV VCB line up of Six panels switchboard consisting of 1250A, VCB 33 KV - 2Nos as incomer with Bus coupler cum Bus Riser 1250A VCB 33 KV-1 No with 1250A VCB 33 KV- 3Nos as outgoing.VCB panel indoortype totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontalisolation, horizontal draw out type VCBs with copper bus bars, Self supported Insulated Busbar with full voltage rated should be used. Complete VCB panel confirming to IEC 62271-200 standards and IP 4X class of protection comprising necessary bus-bars extension and connections and following protective and control devices as specified below. Circuit Breaker shall be suitable for E2, M2 & C2 duty. Vacuum Interrupters of the circuit breakers shall be completely encapsulated in epoxy housing. The manufacturer of circuit breaker & Panel shall also be the manufacturer of the Vacuum Interrupter, Relay. The switchgear and control gear panels shall be of the fully arc proof for 25 kA for 1Sec AFLR complete all as specified and as directed.Make: ABB /CG / Schneider / Siemens. 76 A. INCOMER-2 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories :-a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-200/5+5+5 A Core-1: 15VA Class 0.5, Core -2 5P20, Core -3: Class PS - 3nos.e. Potential Transformer Draw out TypeResin cast Ratio : 33KV/√3/110V/√350VA, CLASS: 0.5-3 Nos.f.12 Window Annunciatorg.Digital Ammeter with ASS.h.Digital Voltmeter with VSS.i.Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.j.Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,k. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS), 87C (differential P) and 64 (Restricted earth fault) .Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 77 B. OUTGOING - 3 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motorb.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-200/5+5A Core-1: 15VA Class 0.5, Core -2 5P20, Core-3 : PS class- 3 nos.e.12 Window Annunciator.f.Digital Ammeter with ASS.g. Digital Voltmeter with VSS.h. Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication i. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,j. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS), 64 (Restricted earth fault).Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 78 C. BUS COUPLER- 1 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,e. Electrical & Mechanical Interlocking.f. Numerical Protection Relay with all protection.g. ABT scheme with Manual Option.Note:The above said panelsEarthing truck -01 nos. Earthing truck shall be so designed that it is impossible to earth alive. It shall be provided with capacitive voltage detection with audio visual annunciation. Technical drgs of the VCB panel submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the VCB panel to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of VCB panel shall be carried out by Senior Electrical Inspector / Electrical Inspector. The VCB panel should be GSM based SCADA compatible. 79 Supply, Installation, Testing and Commissioning of Three Phase 4Wire 110V/50A FCBC Thristor based with in-built DCDB and RS485 communicationsuitable for 110V/200AH VRLA battery with 55 Cellsin complete as specified and directed. Make: Amararaja/Exide 80 Supply, installation, testing and commissioning of cable 3 Core 300 Sq.mm 33KV(E) XLPE cable grade cable of size suitable for earthed system having compacted circular stranded aluminium conductor shielded with semi-conducting compound extruded layer XLPE insulated dry cured core shielded with semi-conducting compound extruded layer followed by metallic copper foil, screened inner sheath of extruded PVC, galvanized single flat steel strip armoured and PVC sheathed overall conforming to IS: 7098/Part-II/1985, as amended upto date with ISI marked of following sizes in VCV manufacturing process.Note- Technical details of the cable submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the cable to be inspected by the rep of accepting officer at Factory premises as per IS before despatch 81 S&F of Cable jointing kit for 33 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 300 Sqmm 3 core complete all as specified and directed. 82 S&F of Cable jointing kit for3 Core 300 Sq.mm 33 KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and directed. 83 S&F of Cable jointing kit for 3 Core 300 Sq.mm 33 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and directed. 84 Supply, laying & testing of 11KV(E)XLPE insulated cable of following sizes suitable for earthed system having compacted circular stranded aluminium conductor shielded with semi-conducting compound extruded layer XLPE insulated dry cured core shielded with semi-conducting compound extruded layer followed by metallic copper foil, screened inner sheath of extruded PVC, galvanized single flat steel strip armoured and PVC sheathed overall conforming to IS: 7098/Part-II/1985, asamended upto date with ISI marked of following sizes in VCV manufacturing process. 85 3 Core 240 Sq.mm 86 3 Core 400 Sq.mm 87 Supply, laying & testing of 11KV(E)XLPE insulated cable of following sizes suitable for earthed system having compacted circular stranded copper conductor 1 core 1000 sqmm shielded with semi-conducting compound extruded layer XLPE insulated dry cured core shielded with semi-conducting compound extruded layer followed by metallic copper foil, screened inner sheath of extruded PVC, galvanized single flat steel strip armoured and PVC sheathed overall conforming to IS: 7098/Part-II/1985, asamended upto date with ISI marked of VCV manufacturing process. 88 S&F for Cable jointing kit for 11 KV grade cable for Outdoor End termination kit heat shrink type joint complete with jointing material and accessories suitable for 1 core 1000 sqmm XLPE armoured copper conductor cable sqmm etc complete all as specified and directed. 89 S&F for Cable jointing kit for 11 KV grade cable for Indoor End termination kit heat shrink type joint complete with jointing material and accessories suitable for 1 core 1000 sqmm XLPE armoured copper conductor cable sqmm etc complete all as specified and directed. 90 S&F for Cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm etc complete all as specified and directed. 91 S&F of Cable jointing kit for 11 KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following sizes etc. complete all as specified and directed. 92 3 Core 240 Sq.mm 93 3 Core 400 Sq.mm 94 Design, Supply, Installation, Testing and Commissioning of GSM based energy management system/ substation automation system with suitable software capable of taking care of complete data monitoring, data logging and control functions at 132 MRS consisting of 2 Nos 132 KV GIS, 6 Nos HT 33 KV VCBs at MRS , 7 Nos 33 KV VCBs at NSB Substation, 8 Nos 11 KV VCBs at NSB and other allied switchgears at 33/11 KV substation at DH complete with servers, work stations, desk top computers, operating system, communication products and object softwares assembled from industry standard products all as specified 95 a) BCU suitable for substation automation.b) Integration with Existing Scada server.c) Fibre/Eithernet switch (for station level & bay level) -8 sets.d) RTU (with redundant RTU , Power Supply & Hot Swappable IO configuration) - 2 set.e) SCADA software.f) Suitable Modems & ALUs.h) Integration with Existing central SCADA software- 1 set.Note- a) The SCADA system is GSM based and to be integrated with existing SCADA server. b) The cost of Connecting cable (e.g-Optical fibre cable Network, CAT 6 cable Armoured/unarmoured etc) and accessories for integration of IED, Ethernet and RTU, ALU, IED (Relay) as required at site is deemed to be included in the unit price. c) Technical drgs of the SCADA submitted by the contractor is required to be approved by the accepting officer before taking procurement action . 96 Supply and fixing in position Retardant/ extinguishing electric insulated synthetic mat2.5 mm (+/-) 10% thick conforming to BIS -DOC No ET-02 (540) dt 30/04/2004, meeting requirements of IS- 3043, IS-5216 (Part-1, 2 & 3), IS-15652:2006 and IEC 479 Pub-I tested having minimum width of 1000 mm (+/-) 20 mm. All allied materials such as PU-Resin Chemical bond (hardener), special PVC adhesive liquid primer and qty required to complete the job as per site requirement suitable for all voltages not exceeding 33/11 KV system complete all as specified. 97 M&L for RCC cable route indicator semi-circular shape on top of size 600x450x100 mm casted in PCC 1:3:6with TMT bar of size 10 mm dia and foundation base casted in RCC 1:2:4, grouted in earth upto 550 mm duly engraved the following letters HT UG CABLEwith two coats of antifungal weather coat paint, etc all as specified and directed. 98 S & F for Display chart (set of 2 nos) of size 6 x 4 duly made on white polyvinyl sheet exactly showing the locations of the yard and the machineries and equipments installed in the sub-station duly marked properly with legends etc, and a separate chart showing the details of machineries installed with nos, capacity/ rating and make with computer cutting letters of approved size on poly vinyl sheet all as specified and directed. 99 S&F for Display chart (set of 2 nos) of size 4 x 5 duly made on white polyvinyl sheet exactly showing the lay out of transmission and distribution of HT UG cable routes, locations of the HT Joints, drawn on autocad, etc duly marked properly with legends, with computer cutting letters of approved size on poly vinyl sheet, all as specified and directed. 100 S & F for shock treatment chartof size 1.5 m x 1.5 m x 0.025 m duly laminated with wooden frame (tick wood)enclosure all as specified and fixed in position as directed by Engineer-in-charge. 101 S & F First aid GI box containing prescribed medicines for first aid box as per standard quality and quantity each as required to provide first aid treatment in an emergency complete all as specified 102 Supply, Installation, Testing and Commissioning of Power transformer step down outdoor type 33/11 KV, capacity 16 MVA (suitable for 10/16MVA cooling), ONAN/ONAF, Vector group Delta/star (Dyn11) with on load tap changing gear (+) 5% to (-)15% in steps of 1.25% on HV side, with HV/LV Cable Box and all standard accessories as per IS 2026 and as specified in PS, including first fill of oil complete comprising the following accessories:-a)Conservator Tankb) Pressure Relief Devicec) Buchholz Relayd) Oil Surge Relaye) Oil Temperature Indicator (OTI)f) Winding Temperature Indicator (WTI)g) Oil Preservation Equipment likeh) Oil Sealingj) Breatherk) Aircell in conservator tankl) Radiators and control valvesm) Each radiator tank shall have its own cooling fans, shut off valves at the top and bottomn) motor operated OLTC shall be o) On load tap changing with RTCC panelp) Marshalling boxq) Thermosphyn filterr) NIFPS to be installed By OEM 103 Note- i) Technical drgs of the Transformer alongwith NIFPS submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the Transformer to be inspected by the rep of accepting officer at various stages at Factory premises as per IS before despatch. Pre-commissioning inspection of Transformer shall be carried out by Senior Electrical Inspector / Electrical Inspector.ii) The rate quoted is deemed to include the cost of PCC / Brick Masonry Foundation / Platform of transformer as per OEM recommendations and finishing the top surface even and smooth.iii) Manufacturer shall possess NABL accredited test lab for electrical testing(Routine test, type test and special test.iv) Type test reports of33/11 KV Transformer of same capacity or higher Such as Temperature rise, Impulse test, Short circuit test , Vacuum Tests of Tank & Radiator, No Load & Load Loss test and tap changer to be submitted by the bidder during Drawing approval 104 Supplying, Installing, Connecting, Commissioning and Testing of Transformer, Step Down, Outdoor Type, Floor or Platform Mounted complete with standard fittings, 33 KV / 433 V [at No load], AC, 3 Phase, 50 Hz, of 100 KVA capacity, Double Copper Wound, K class Natural Ester Oil immersed, CRGO Core type Naturally cooled, Built-up with class A insulation, having Primary Voltage [HT] 33 KV and Secondary Voltage [LT] of 433 Volts, Delta connected on 33 KV Side & Star connected on 433 Volts side, designed & constructed with particular reference to Tropical Condition, conforming to IS – 1180-2014, including PCC / Brick Masonry Foundation / Platform as per IE Rules, fixing HT / LT Busbar and Cables etc. complete all as specified and as directed andcomprising of the following Specification and Fittings:Continuous Rating: 100 KVANo-Load Voltage Ratio : 33 KV / 433 V Tapping on HV[%]: ± 7.5, ± 5, ± 2.5Phase & Frequency : 3 Phase & 50 HzConnection: Delta StarVector Group : DYN 11Cooling : KNANType: OutdoorNote: The rate quoted is deemed to include the cost of PCC / Brick Masonry Foundation / Platform as per OEM recommendations and finishing the top surface even and smooth complete all as per manufacturer’s recommendations, as specified and as directed. 105 Fittings:[a] Externally hand operated Off–Circuit Tap Switch with position indicator and locking device.[b] Conservator with Oil Gauge, filling hole with plug & drain hole with plug[c] Undercarriage with four plain rollers[d] Oil filling hole cum air release plug[e] Drain Valve cum Sampling Valve[f] Top Filter Valve with Plug[g] Rating Plate with Diagram Plate[h] Lifting lugs for Transformer[j] Lifting lugs for Core[k] Earthing Terminals[l] Thermometer Pockets[m] Silica Gel Breather[n] Explosion Vent[o] Marshalling Box with Double Window[p] OCTC.Note- Technical drgs of the Transformer submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the Transformer to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of Transformer shall be carried out by Senior Electrical Inspector / Electrical Inspector. 106 Supply, Installation, testing & commissioning ofHT 33KV VCB line up Seven panels switchboard consisting of 1250A, VCB 33 KV - 2Nos as incomer with Bus coupler cum Bus Riser 1250A VCB 33 KV-1 No with 1250A VCB 33 KV- 4Nos as outgoing.VCB panel indoortype totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontalisolation, horizontal draw out type VCBs with copper bus bars, Self supported Insulated Busbar with full voltage rated should be used. Complete VCB panel confirming to IEC 62271-200 standards and IP 4X class of protection comprising necessary bus-bars extension and connections and following protective and control devices as specified below. Circuit Breaker shall be suitable for E2, M2 & C2 duty. Vacuum Interrupters of the circuit breakers shall be completely encapsulated in epoxy housing. The manufacturer of circuit breaker & Panel shall also be the manufacturer of the Vacuum Interrupter, Relay. The switchgear and control gear panels shall be of the fully arc proof for 25 kA for 1Sec AFLR complete all as specified and as directed.Make: ABB /CG / Schneider / Siemens. 107 A INCOMER-2 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories .a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-200/5+5 Core-1: 15VA Class 0.5, Core -2 5P20 - 3nos.e. Potential Transformer Draw out Type Resin cast Ratio : 33KV/√3/110V/√3100VA, CLASS: 0.5-3 Nos.f.12 Window Annunciator.g.Digital Ammeter with ASS.h.Digital Voltmeter with VSS.i.Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.j.Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,k. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS) and 64 (Restricted earth fault) Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 108 B. OUTGOING - 4 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-200/5+5+5A Core-1: 15VA Class 0.5, Core -2 5P20, Core -3: Class PS - 3nos.e.12 Window Annunciator.f.Digital Ammeter with ASS.g. Digital Voltmeter with VSS.h. Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.i. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,j. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS),Transformer Differential Protecton (except Stn Transformer )64 (Restricted earth fault) Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 109 C. BUSCOUPLER- 1 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,e. Electrical & Mechanical Interlocking.f. Numerical Protection Relay.g. ABT scheme with Manual Option.Note:The above said panelsEarthing truck -01 nos. Separate earthing truckfor bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth alive. It shall be provided with capacitive voltage detection with audio visual annunciation.Technical drgs of the VCB panel submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the VCB panel to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of VCB panel shall be carried out by Senior Electrical Inspector / Electrical Inspector. The VCB panel should be GSM based SCADA compatible. 110 Supply, Installation, testing & commissioning ofHT 11KV, 25 kA, VCB line of Nine panels switchboard consisting of 1250 Amps, VCB 11 KV - 02 Nos as Incomer, Bus coupler 1250Amps VCB 11 KV -1Nos , Outoing 1250AVCB 11 KV- 6 Nos.VCB panel indoortype totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontalisolation, horizontal draw out type VCBs with copper bus bars, Self supported Insulated Busbar with full voltage rated should be used. The switchgear panel shall be of sheet steel constructionnot less than 2.5mm thickness for load bearing section and not less than 2 mm thickness for non-load bearing and shall totally dust and vermin proof. Complete VCB panel confirming to IEC 62271-200 standards and IP 4X class of protection comprising necessary bus-bars extension and connections and following protective and control devices as specified below. Circuit Breaker shall be suitable for E2, M2, C2duty. The manufacturer of circuit breaker & Panel shall also be the manufacturer of the Vacuum Interrupter, Relay. The switchgear and control gear panels shall be of the fully arc proof for 25 kA for 1Sec AFLR complete Make: ABB /CG / Schneider / Siemens. 111 A. INCOMER-2 Nos ( Each consisting of )11kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories:-a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 800-600-400/5+5+5A Core-1: 15VA Class 0.5, Core -2 5P20, Core -3: Class PS - 3nos.e. Potential Transformer Draw out Type Resin cast Ratio : 11KV/√3/110V/√3100VA, CLASS: 0.5-3 Nos.f.12 Window Annunciator.g.Digital Ammeter with ASS.h.Digital Voltmeter with VSS.i.Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.j.Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,l. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS),Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 112 B. OUTGOING - 6 Nos ( Each consisting of )11kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-300-200/5-5A Core-1: 15VA Class 0.5, Core -2 5P20 - 3 nos.e.12 Window Annunciator.f.Digital Ammeter with ASS.g. Digital Voltmeter with VSS.h. Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.i. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,j. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS).Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 113 C. BUSCOUPLER- 1 Nos ( Each consisting of )11kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,e. Electrical & Mechanical Interlocking, ABT scheme with Manual option.Note: The above said panelsEarthing truck -02 nos. Separate earthing truckfor bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth alive. It shall be provided with capacitive voltage detection with audio visual annunciation. Technical drgs of the VCB panel submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the VCB panelto be inspected by rep of the accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of VCB panelshall be carried out by Senior Electrical Inspector / Electrical Inspector. The VCB panel should be GSM based SCADA compatible. 114 Supply, install, test and commission of APFC panel indoor type 1500 KVAR 12.1 KV, complete Make : CG / Shreem /Siemens /BCH.Capacitor panel consisting of below:-83.33 KVAR, 6.98 KV, externally fused capacitor unit for 250K @12.1KV (207K 11KV) step - 12nos.166.67 KVAR, 6.98 KV, externally fused capacitor unit for 500K @12.11 KV (413K 11KV) step - 3nos.11 KV, Air core dry type, class F aluminium wound, 1Ph, 0.2%, series reactor (STC shall be 16.6 times rated current for 2 sec) - 15nos.11KV, 400A, 10KA for 1 Sec, 3 phase vacuum contactor - 15nos.11 KV/110V-190V, 50-50VA, 3Ф resin cast RVT - 1no.11 KV HT HRC fuses of suitable current rating- 15nos.11 KV, 630Amp, 25KA for 1 sec, off load type isolator- 1no.3PH, RC surge suppressor- 1no.APFC relay (RS485/232 communication port)- 1no.Control cable, space heater, timer, thermostat, CFL lamp, LED indication, push button, selector switch, terminal connectors, gasket, limit switch, name plate, hardware - 1 set. 115 S& F spring loaded aluminium clamps suitable for HV & EHV cables of following sizes inculding all necessary items to fix such as nuts, bolts, washers etc. and all fixing arrangements as required at site. 116 Single core 630 Sqmm 132 KV Al cable 117 Three core 300 Sqmm 33 KV Al cable 118 M & L for survey, site inspection, layout design and location identification for complete earthing/earth mat layouting for best result depending on the soil condition at the site of 132KV and 33 KV yard all complete as specified and directed. Survey report alongwith layout drawing in A3 size properly verified by a Engineer to be submitted in triplicate for approval of Engr in charge/GE 119 Material and labour for brick massonary in cement mortar 1:4 of internal size 1000 x 1000 x 800mm for man hole in contol/power cable routes including plastering with cement mortar 1:6 10MM thick internally and externally 150mm below the G.L. with 1:6 cement mortar 15mm thick,PCC 1:4:8type D2 by using 40mm gradded aggregate foundation of size 1550x1550 mm of 150mm thick and PCC 1:3:6 for coping of 50mm thick and covering the chamber with 40X40X4 mm thick angle iron frame and 10mm thick RCC slab with type B0 1:2:4 concrete with 12.5mm graded aggregate as cover with handles made out of MS round bar 10 mm dia for lifting slabs including painting to the angle iron with two coats of synthetic enamel paint over a coat of redoxide primer and white wash for the man hole complete all as directed by Engineer-in-charge. 120 Material and labour for brick massonary in cement mortar 1:4 of internal size 1500 x 1500 x 1400mm for man hole in control cable routes including plastering with cement mortar 1:6 10MM thick internally and externally 150mm below the G.L. with 1:6 cement mortar 15mm thick,PCC 1:4:8type D2 by using 40mm gradded aggregate foundation of size 1550x1550 mm of 150mm thick and PCC 1:3:6 for coping of 50mm thick and covering the chamber with 40X40X4 mm thick angle iron frame and 10mm thick RCC slab with type B0 1:2:4 concrete with 12.5mm graded aggregate as cover with handles made out of MS round bar 10 mm dia for lifting slabs including painting to the angle iron with two coats of synthetic enamel paint over a coat of redoxide primer and white wash for the man hole complete all as directed by Engineer-in-charge. 121 M&L for Providing precastreinforced cement concrete slabs 12.5 cm thick M-30 including reinforcementand 12 mm dia MS handle (with plain or interlocking joints as directed setting in mortar 1:6 of size of slab 1.20x1.20M. 122 LIGHTENING PROTECTION 123 M & L for single pointed Air termination Aluminium Rod 12 mm dia 500 mm long with Aluminium base plate of size 125 x 125 x 10mm fixed over hylam sheet of size 175 x 175 x 10mm and fixed on 1.5 Meter GI pipe 25mm Medium grade on roof all specified and as directed. 124 M & L Earthing complete with GI earth plate electrode 60cmX60cmX6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connecting to galvanized earth strip 32 x 6 mm as earthing conductor by means of bolts, nuts, check nuts and washers of GI and all as shown in Electrical plate No.3 of SSR Part I and including testing on completion all as specified locations and as directed by the Engineer-in-Charge.Note: 1.The above quoted rate shall include cost of main earthing lead of 32 x 6mm GI earth strip, charcoal, salt, excavation and earth work in any type of soil CI cover, funnel with 20mm dia medium grade GIwater pipe including GI protection pipe 40mm dia light grade for earth strip etc., 2. The cost of earth pit is deemed to be included in the unit rate. 125 AC & REF 126 Supply and install split AC units indoor/outdoorof capacity 2 TR, 3 star , Inverter type, single phase complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with copper condenser complete all as specified and directed 127 S& F Voltage Stabiliser 5 KVA, operating voltage range 130-290 Volt, Single phase complete all as specified and directed. 128 SCHEDULE A PART-IXPHASE -II Outsourcing for sub station for the First 11 Monthsduring Defect Liability Period . 129 Outsourcing for manning and operationof HT/LT Electrical sub station at 33/11 KV substation at NSB along with connected equipments installed round the clock (in 03 shifts) of each shift of 08 hours per day including Sunday and holidays complete all as specified and as directed. 130 One skilled operator in each shift 131 One semi skilled operator in each shift 132 SCHEDULE A PART-XPHASE -III Outsourcing for sub station for the Second 11 Monthsduring Defect Liability Period . 133 Outsourcing for manning and operationof HT/LT Electrical sub station at 33/11 KV substation at NSB along with connected equipments installed round the clock (in 03 shifts) of each shift of 08 hours per day including Sunday and holidays complete all as specified and as directed. 134 One skilled operator in each shift 135 One semi skilled operator in each shift 136 SCHEDULE A PART-XIPHASE -IV Outsourcing for sub station for the balance 02 Months after 22 months during Defect Liability Period . 137 Outsourcing for manning and operationof HT/LT Electrical sub station at 33/11 KV substation at NSB along with connected equipments installed round the clock (in 03 shifts) of each shift of 08 hours per day including Sunday and holidays complete all as specified and as directed. 138 One skilled operator in each shift 139 One semi skilled operator in each shift 140 Note for Item No. 127 to 138:-The rate shall include the following[i] For operation of all out door and indoor structures in the same area.[ii] Contractor shall laise with Dolphin hill sub station in case of major breakdown for early restoration of supply.[iii] In case any problem occurs which seems not under thecontrol of the operator, the same shall be immediately intimated to JE/ AGE E/M.[iv] Any additional man power required for early restoration of supply in case of emergency shall be provided by the contractor.[v] The contractor shall abide by the latest labour rules and minimum wages Act. Wages paid by the contractor to the emplopyed persons shall not be less than minimum wages fixed by the state/ central Govt from time to time whichever is higher.[vi] The contractor shall also insure the workmen employed on th job.[vii] The contractor is responsible for insurance, EPF, ESI, labour welfare cess etc., as applicable and shall be paid to the workmen as per existing Rules/ Acts/ regulations etc., and quoted is deemed to include the same. 141 SCHEDULE A PART-XIIPHASE -VOutsourcing for SCADA system for the First Year after Defect Liability Period . 142 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 143 SCHEDULE A PART-XIIIPHASE -VIOutsourcing for SCADA system for the Second Year after Defect Liability Period . 144 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 145 SCHEDULE A PART-XIVPHASE -VIIOutsourcing for SCADA system for the Third Year after Defect Liability Period . 146 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 147 SCHEDULE A PART-XVPHASE -VIIIOutsourcing for SCADA system for the Fourth Year after Defect Liability Period . 148 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 149 SCHEDULE A PART-XVIPHASE -IXOutsourcing for SCADA system for the Fifth year after Defect Liability Period . 150 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 151 SCHEDULE A PART-XVIIPHASE -XOutsourcing for SCADA system for the Sixth year after Defect Liability Period . 152 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 153 SCHEDULE A PART-XVIIIPHASE -XIOutsourcing for SCADA system for the Seventh year after Defect Liability Period . 154 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 155 SCHEDULE A PART-XIXPHASE -XIIOutsourcing for SCADA system for the Eighth year after Defect Liability Period . 156 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 157 Note for Item No. 140 to 155 [i] Cost of all minor spares/ components including OFC cables, Ethernet switches, connectors etc., is deemed to be included in quoted rate and any type of extra charge will not be made by Dept.[ii] All major defective spares shall be replaced by contractor on exchange basis which is deemed to be included in the unit price.[iii] All periodical tests of all safety devices in accordance with relavant safety standards with full oad testing will be borne by the contractor.[iv] Systematically examine & repair all the components such as software, monitors, servers etc., if any defect found,[v] All required special tools to be arranged by the contractor.[vi] Contractor shall be responsible for maintaining adequate lighting, cooling and moisture control, ventilation as required all at site complete.[vii] All safety measures/ directions and required tests for safety devices annually shall be borne by contractor.[viii] All periodical visits and all breakdown calls related to stoppage, malfunction, special services should be attended compulsory during all days including sundays & holidays.[ix] The contractor shall be liable to pay the telecom bill provided by the service provider.
Contract Date: Jan 06, 2026 Contract Value : 23.55 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
Andhra Pradesh View Result →
39.
Defence #9920442 AOC
Tender For Special Repair Of Pump Motor And Misc Items Against Ber In Outlaying Area; 1 Supply, installation , testing and commissioning of end suction & top discharge, non self priming , single phase, centrifugal volute type pump having cast iron casing, enclosed type dynamically balanced phosphor - bronze/ SS impeller , hight tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep grove ball bearings, TEFC squirrel cage induction motor having IE-3 efficency, confirming to IS 12615-2018 at 2900 RPM speed star/delta starter panel, base plate, mounting chanel frame, accessories and fittings, viz mechanical seal, pressure gauges, thermometer , drain, coupling, coupling gaurd, vibration isolation arrangement by means of spring/ rubber type mounting suitable for operation no 3 phase, 415V +10% , 50 Hz AC supply including foundation as per manufacturer recommendation complete all as specified and directed by Engr in Charge. 2 Horizontal end suction long coupled pump with insulation 7.5 LPS water flow rate at 26 mtr head for domestic supply. 3 Horizontal end suction long coupled pump with insulation 9.3 LPS water flow rate at 45 mtr head for domestic supply. 4 Horizontal end suction long coupled pump with insulation 34 LPS water flow rate at 75 mtr head for domestic supply. 5 Supply, fix, install, testing and commissioning of LT Panel,indoor type cubical shape,three phase, 4 wire, copper bus barrating 400 amps for phases and 200 amps for neutral made out of CRCA sheet ,2 mm thick ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frameand four legs of 50x50x6mm thick angle iron ,1 ft long grouted on PCC foundation of height not less than 40 cm from the ground level , grouting properly ,and of suitable size to accommodate the items mentioned belowand having separate compartment /chambers for cable gallery busbar,switch gearand front side door openable , back side fixedwall etc all as specified and comprising of following including necessary cable connections to the MCCBs ,voltmeter,Ammeter and cable lugs etc with the following accessories:-(i) MCCB 4 Pole, 415V, adjustable type, 250 Amps with breaking capacity 25KA -01 No (Incoming)(ii)MCCB 4 pole 415V fixed type, 25 to 160 Amps with breaking capacity 16KA-03 Nos (outgoing) (iii)Motorstar delta startersuitable for UPTO 40HP motor - 02 Nos(iv) Voltmeter/ Ammeter,digital type 0- 400 volt,with selector switch -03 set(v) Phase indicating lamps LED type ( red , yellow, blue) -03 set(vi)MCB SPN 40 Amps- 06 Nos (outgoing) 6 Supply, install, testing and commissioning of motoron /off LT PanelCPRI Approved mounted on angle iron frame 40x40x5 mm grouted on floor,cubical indoor type, with frontside opening or suitable fixing of all breakers and controls for 415V, 3 phase,made of 2 mm thick CRCA sheet weather, vermin proof factroy fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 600 Amps rated bus bar, top and bottom cable entry including disconnecting cable connections Panel and fixing/connecting in new installed panel with provisions of thimble/lugs and necessary framework and PCC foundation including shifting of existing LT Panel of any making arrengement for fixing of panel and making good to disturbed surface as directedcomprising of the following :-(a)Motorstar delta startersuitable for UPTO 12.5HP motor - 02 Nos(b) MCCB 250Amps, 36 KA FP - 01 Nos (c) MCCB 100Amps, 36 KA, FP - 04 Nos (d) control panelwiring with 2.50 sq mm multistranded, pvc insulated copper conductor cable between voltmeter, Am meter, and their selector switch complete withCTs of ratio 400/5A- 2 Nos,320/5 A- 2 Nos , 250/5 A- 2 Nos ,200/5 A - 2 Nos , 160/5 A - 2 Nos , voltmeter flush pattern type 96 mm square dial -1 nos, Am- meter digitalCT operated 96 mm sqare dial flush pattern type -10 Nos, indication lamp for 3 phase and control fuses-3 Nos complete .(e) Aluminium bus bar 400 Amps for phase & 200 Amps for neutral complete with bus bar insulator,nuts & bolts complete.(f) Power panel wiring between bus bar to MCCB of different capacity with PVC insulated multistranded copper cable , 10 Sqmm ,singlecore ,1100 volts grade of appropriate size complete with copper lugs.(g) Digital Ammeter-03 No(f)Digital Voltmeter-03 No (g) Phase indicator lamp R,Y & B with slector switch - 03 Set 7 S&F in repair, testing and commissioning weather and vermin proof factory made manufactured by a CPRI approved factory, floor mounted, out door cubicle type double doortotally enclosed LT panel fabricated out of 3 mm thick CRCA sheetwith extended hood to arrest rain beat with MS angle iron frame made out of angle iron 45 x 45 x 6 mmsuitable for operation on 3 phase 4 wire 415 volt 50 HZ system, dust & vermin proof, front and rear operated, hinged panel doors coverstwo sides openablewith handles , locking arrangements and consisting of sufficient number of cable cutting holes at bottom for inserting incomming /out going cables with suitable PVC /Rubber bushes to arrest entry of water /vermin etcand fixed with chromiumplated brass cable glands to connect the cables of suitable sizes internal power wiring, adequataluminium strips for bus barsand stranded copper cables size suitable to the capacity of MCCBs an other controls including internal compartments using 3 mmthick CRCA sheet metal powder coated connecting all cables properly and consisting of the following controls and fitment in LT panel complete all as directed by Engineer - in -charge. 8 INCOMING(a) MCCB 250A, rated for 415Volt, 4 pole, 3 Phase, rupturing capacity of 36KA, Thermal-Magnetic type MCCB, Qty-01 No (. incoming), the service short circuit breaking capacity (Ics) shall be equal to ultimate breaking capacity (Icu) i.e. Ics =100% Icu. (Thermal adjustment and magnetic adjustment setting) (b)Bus bar of aluminium strip of suitable cross section to with stand 250 Amps rating 3 phase and half of the phase capacityfor neutral mounted on Epoxy/FRP bus bar insulator and colour codingOUTGOING :(a) MCCB 160A, Rated for415Volt, 4 pole, 3 Phase rupturing capacity of 16KA, Thermal-Magnetic type MCCB, Qty-04 No. (Outgoing) the service short circuit breaking capacity (Ics) shall be equal to ultimate breaking capacity (Icu) i.e. Ics =100% Icu. Fixed Thermaland magnetic setting (b) MCBSPN , 230 Volts, 63 Amps,10 KA -04 Nos (c) Indicator lamp (RYB) (set of three) - 01 Set (d) Digital Ammeter 0-200 Ampswith selector switch - 01 No (e) Digital Voltmeter 0-500 V with selector switch - 01 No.(f) Earting studs welded on body of pillar box- 02 Nos(g) Indicator lamp RYB LED Type(h) Necessary cable glands/cable lugs of suitable sizes. (j)Angle iron mounting support made of 50 X 50 X 6 mm including grounting in PCC 1:2:4, 4 lugs 60 cm height gounted 15 cm in ground including earth work complete (k) Testing and commissioning for insulation and earthing complete. 9 M&L for Construction ofbrick masonry valve pit chamber of size (105 x 105 x 105cm (finished internal dimensions ) using sub class Bbrick masonry in cement mortar cm 1:4 including plastering internally in CM 1:4 including1:4:8 using 40 mm gradedaggregate over 100 mm hardcore and painted flush externally as the work proceeds and PCC 1:2:4 type B-1 as in coppingwith repair/welding ofangle iron frame 40 mm x 40 mm x 6 mm with 2 mm thick MS sheet cover two side openwith 2 Nos hinges each side and 2 Nos lifting handle and in built locking arrangement including lock and key and surface with two coats of synthetic black paint and a coats of red oxide paint on steel surface including necessary excavation in any type of soil, earth work in any type of soil to distance n.exc 50 m all as specified also included in this schedule of rate including returning/filling of earth and removingsurplus soil as decided. 10 S&F in repair 200 MM ISI marked MS ERW pipes with all accessories like all fittings including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer, including supporting/fixing the pipe on floor/wall/ceiling with clamps, hangers, angles, channels (using anchor fastners) with painting of one coat primer and 2 or more coats of synthetic enamel paint complete all as specified and directed by the engineer-in-charge. 11 S&F in repair 150 MM ISI marked MS ERW pipes with all accessories like all fittings including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer, including supporting/fixing the pipe on floor/wall/ceiling with clamps, hangers, angles, channels (using anchor fastners) with painting of one coat primer and 2 or more coats of synthetic enamel paint complete all as specified and directed by the engineer-in-charge. 12 S&F in repair 100 MM ISI marked MS ERW pipes with all accessories like all fittings including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer, including supporting/fixing the pipe on floor/wall/ceiling with clamps, hangers, angles, channels (using anchor fastners) with painting of one coat primer and 2 or more coats of synthetic enamel paint complete all as specified and directed by the engineer-in-charge. 13 S&F in repair 80 MM ISI marked MS ERW pipes with all accessories like all fittings including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer, including supporting/fixing the pipe on floor/wall/ceiling with clamps, hangers, angles, channels (using anchor fastners) with painting of one coat primer and 2 or more coats of synthetic enamel paint complete all as specified and directed by the engineer-in-charge. 14 M&L for PCC 1:3:6 type C2 (using 40 mm graded crushed stone aggregate) for filling in hard standing/ plinth protectionofsemi under tank and suporttomain raw water supply lineallas directed by Engineer-in-Charge. 15 Supply and fix in repair GI tubing medium grade in trenches including provision of fitting and accessories in trenches/wall/shaft for diversion and improvement in water supply line complete all as specified and directed by Engineer-in-Charge for the following sizes:- 16 40 mm bore 17 50 mm bore 18 80 mm bore 19 100 mm bore 20 150 mm bore 21 Excavationin trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and taking out soft/loose soil for laying of cable /Laying of pipe/evection of pole/stay pit excavation eomplete all as specified and directed by Engr in Charge. 22 Returning and filling including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified and directed by Engr in Charge. 23 Removing excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specifed and directed by Engr in Charge.
Contract Date: Jan 05, 2026 Contract Value : 36.75 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Maharashtra View Result →
40.
Defence #9913771 AOC
Tender For Repair/Maintenance Of Dg Set, Solar Water Heater, Chlorine Plants, Lifts And Stps Under Ge (I) Kanpur.; 1 Servicing / maint of solar water heater system of capacity up to 750 ltr including dismantling the required parts after that de-scaling, cleaning of water tank, cleaning of pipe, air vent, eliminator etc and refixing the dismantled parts at its original position to make solar water heater functional by replacement of minor accessories and testing on completion complete all as specified and directed. Notes:- (i) Minor spares i.e nut, bolt, washers, wire or other minor parts if required shall deems to be included in this job. (ii) Any accessories found unserviceable that shall be replaced & paid under respective items of this Sch as supply only and cost of fixing of the same shall be deemed to included in this item. 2 Supply only PVC hose pipe for Solar water heating system including clamps, washers, bolts etc where ever reqd complete all as specified and directed. 3 Supply only of thermostat with connected fittings complete all as specified and directed. 4 Supply only of air vent valve complete all as specified and directed. 5 Supply only of drain valve complete all as specified and directed. 6 Supply only of shutt off valve complete all as specified and directed. 7 S&F 20 mm bore GI pipe medium grade ISI marked with all fittings and fixed to walls / roofs or laid in floors / plinth protection including making good disturbed surfaces with cement mortar (1:3) to match with existing surfaces complete all as specified and directed. 8 M&L High density polyethylene (HDPE) pipes of pressure rating 6 kgf/sqcm / Polypropylene Random Copolymer (PP-R) pipes with all fitting / fixture (for hot and cold water supply) fixure to wall / floor of 20 mm dia pipe complete all as specified and directed. 9 S&F 20 mm dia stop valve chromium plated cast copper alloy, fancy type high pressure with capstan head screwed both ends for iron / PP-R pipe or for union complete all as specified and directed. 10 S&F Solar Flat Plate Collector OF Selective Black chrome with Nickel Undercoat absorber, Italian design, (screw less construction for durability) Copper riser tube dia 12.5mm x 0.55mm thick, 9 risers, Copper header tube dia 25.4 mm x 0.72mm thk x 1120 mm length, Toughened glass 4mm thick transmittance up to 87%, Aluminum-PU coated frame, Box Type Structure body, Glass wool and Rock wool insulation, Back Insulation - 50mm thick, Side Insulation - 25mm thick, 48 Kg/Mtr cube insulation density, Stainless Steel - SS 304L, having 6 bar pressure complete all as specified and directed. 11 S&F in replacement of SS-304 pressurized tank 300 ltr and puff insulation 4 kg/sqcm working pressure with MS Stand complete all as specified and directed. 12 S&F in replacement of SS-304 pressurized tank 500 ltr and puff insulation 4 kg/sqcm working pressure with MS Stand complete all as specified and directed. 13 S&F in replacement of SS-304 pressurized tank 750 ltr and puff insulation 4 kg/sqcm working pressure with MS Stand complete all as specified and directed. 14 S&F in replacement of ETC tube size 58mm x 1800 mm solar water collector complete all as specified and directed. 15 S&F in replacement of ETC tube size 58mm x 2100 mm solar water collector complete all as specified and directed. 16 S&F in replacement of ETC Coupler flange set complete all as specified and directed. 17 S&F rotational moulded polyethylene water storage tanks, 250 capacity (cylindrical veryical with closed top) hoisted and fixed in position all as specified in SSR Part I, including MS stand of suitable size as per recommendations of solar water heater, including two coats of anticorrosive paint over and including a coat of anticorrosive primer complete all as specified and directed. 18 S&F in replacement of Mild steel framed/sheet work for tanks/panel/pump cage supported structure/ladder and similar works conforming to Fe-290 Gde-E-165 including welding/cutting of steel including painting of two coats of synthetic enamel paint over and including one coat of primer paint (incl preparation of surface) complete all as specified and directed. 19 S&F in replacement of change over switch on load 415 volt in sheet metal enclouser 4 pole of capacity 125 Amps incl disconnecting and dismantling old and fixing on wall making electric connection with existing cable complete all as specified and directed. 20 M&L for hot lagging and wrapping on GI / PP-R pipe used in internal plumping work all around with bonded mineral wool performed snap on pipe section of density 48 Kg / cum conforming to IS 9842 and covered with required size of glass wool and aluminium cladding of required size for up to 20 mm bore pipe complete all as specified and directed. 21 S&F heating element 1500/2000 watt capacity suitable for solar water heaterpush / screw type with O ring including making electrical connection complete all as specified and directed. 22 M&L for fixing glass wool insulation for Hot water pipe complete all as specified and directed. 23 S&F in replacement of air eliminator complete all as specified and directed. 24 Taking / liftingout defective submersible type raw sewagepumps set of capacity 1.1 KW/2760 RPM from raw sewage sump with column pipe steel rope, submersible cable and accessories, including cleaning, greasing , oiling of bearing of electric motor, impeller shaft and relowering the same after repairing works including replacement of worn out parts as per requirement and testing complete all as specified and directed. 25 M&L for rewinding of submersible type sewage motor 1.1 KW/2760 RPM with existing same type & gauge of winding wire as per motor capacity using new insulation material such as insulating paper sleeves etc.including cleaning and replacement of defective parts complete all as specified and directed. 26 Taking out defective Air blower with motor of capacity 3 KW/1400 RPM with all accessories, including cleaning, greasing,oiling of bearing of electric motor and refixing, including cleaning, greasing, oiling of bearing of electric motor, impeller shaft and commissioning the same after repairing works including replacement of bearing and testing complete all as specified and directed. 27 M&L for rewinding of Air blower motor of capacity 3 KW/1400 RPM with existing same type & gauge of winding wire as per motor capacity using new insulation material such as insulating paper sleeves etc.including cleaning and replacement of defective parts complete all as specified and directed. 28 Supply and replacement of air filter for air blower of capacity 3 KW as per existing pattern/make complete all as specified and directed. 29 Taking out defective Monoblock centrifugal pump set of capacity 5.5 KW/1500 RPM with all accessories including cleaning, greasing , oiling of bearing of electric motor and refixing the same after repairing works including replacement of worn out parts as per requirement and testing complete all as specified and directed. 30 Supply and fixing of Contactor Model No MNX-12 making proper connection with suitble lugs complete all as specified and directed. 31 S&F MCB SPN240 volts 40 Amp including connection with suitable size aluminium / copper lugs complete all as specified and directed. 32 M&L for earthing with GIplate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main controlboard and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 including taking down old unserviceable and making test point and all connections complete all as specified and directed. 33 M&L for cleaning raw sewage chamber and cleaning all foreign Materials complete all as specified and directed. 34 M&L for draining out sewage water from Fludized Aerobic Bed (FAB) reactor and cleaning and washing the same and inlet /outlet pipes complete all as specified and directed. 35 M&L for drain out sewage water from Tube settler tank and cleaning and washing the same and inlet /outlet pipes complete all as specified and directed. 36 M&L for drain out sewage water from treated watertank and cleaning and washing the same and inlet /outlet pipes complete all as specified and directed. 37 M&L for cleaning of bushes shrubs, grass around out side of STP upto 2 meter between fencing & road complete all as specified and directed. Note : Necessary tools for cleaning will be arranged by the contractor with out any extra cost. 38 M&L for plastic filter media for enhancedbacterial development in filter tank used in STP plant complete all as specified and directed. 39 Removing of dried sludge from sludge drying bed and depositing the same at a distance of not less than 200 mtr from plant complete all as specified and directed. 40 Supply and replacement of butter fly valve of size 50 mm bore ISI marked heavy duty including suitable nut,bolt & washer complete all as specified and directed. 41 Supply and filling of oil ENKLO 320 or equivalentfor air blower of capacity 3 KW complete all as specified and directed. 42 Supply& Pouring sodium hypo chloride ( Chloine percentage 10-11%) in treated sewage water in manufacturer standard packing complete all as specified and directed. 43 M&L for testing of treated water of STP (Monthly) from any NABL approved laboratory and submit the report timely complete all as specified and directed. 44 M&L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework and all the articles shall be painted with synthetic enamel paint over and including a coat of red oxide complete all as specified and directed. 45 M&L for painting of steel and iron surfaces with one coat of synthetic enemelled paint after preparation of old painted surfaces of STP 100 KLD capacity of STP complete all as specified and directed. Note:- Bidder are advised to visit the site before quoting the tender to find out actual qty of painting. 46 Minor repair/cleaning/servicing/maintenance and testing of chlorine granuals based dosing plant comprising of dosing pump, agitator and FRP tank and connected pipe lines etc once in a week complete all as specified and directed:- Note : (a) Testing of chlorine at consumer end with medical authority and maintained chlorine test record once a week on a register and submit report to concern JE E&M/Engr-in-Charge.(b) Servicing of Agitator of by using necessary lubricant, replacement of bush/bearing, alingning the shaft , key etc. deemed to be included in item rate.(c)Any other spares required for replacement shall be supplied and fixed under relevent item of Sch A. (d) If any defect found in plant contractor should rectify the defect with in 24 Hrs, if failed to rectify the decfectthe contractor shall be liable to pay compensation Rs 500/- (Rupees five hundred only) per plant per day. 47 S&F in replacement of Motor 230 volt, 50 Hz, voltage input 230 volt single phase 50 Hz, current consumption 0.4 Ampr power 120 watt, speed 4 pole induction non synchronous 920 RPM Approx under lead motor shaft dia 15mm X Length 50 mm motor is flange mounted 4 no of 7 mm dia hole at PCD 150 mm incl all fixing arrangement complete all as specified and directed. 48 S&F in replacement of shaft with impeller made out of MOC poly propelene rigid dia 32 mm X Length 500 mm impeller type two bladed pitched blade turbine numbar of impeller- I incl all fixing arrangements complete all as specified and directed. 49 S&F in replacement of Dosing tank only capacity 100 Ltrs MOC PE FRP Ltd contaning port hole for pouring chlorination chemical and water them necessary provision for mounting of moter at proper angel provision for mounting dosing pump on lid level gauge complete all as specified and directed. 50 S&F in replacement of Rotor assembly with bearing brackets & tolerance ring complete all as specified and directed. 51 S&F in replacement of Single head feet rate control with shaft complete all as specified and directed. 52 S&F in replacement of Pump head (ferrules 1/4 & duchbill included) complete all as specified and directed. 53 S&F in replacement of Pump tube complete all as specified and directed. 54 S&F in replacement of Injection check valve complete all as specified and directed. 55 S&F in replacement of Weighted suction line strainer 3/8 complete all as specified and directed. 56 S&F in replacement of 3/8 white suction/discharge tubing complete all as specified and directed. 57 S&F in replacement of Check valve duckbill only (PK-5) complete all as specified and directed. 58 S&F in replacement of Gear motor complete 230 volt 50 Hz complete all as specified and directed. 59 S&F in replacement of Coil 250 volt 50 Hz complete all as specified and directed. 60 S&F in replacement of Roller Assembly complete all as specified and directed. 61 S&F in replacement of dosing pump (Model No 96 NGQ 51) high pressure single head geared motor adustable dosing having output upto 40 US GPD and pressure upto 7 kg/cm2 with connecing accessories complete all as specified and directed. 62 Supply & Pouring Calcium based high strenght granular chlorination chemical having 65 % to 70 % active chlorine, whitish, free flowing, decomposes clear in water solution, free of foriegn matter , the chlorination chemical should contain appropriate quantities of dispersants, corossion inhibitors to prevent incrustation scaling in distribution systems, mercury and other heavy meatl conteminents in chlorination chemical must be Below Detectable Limit (BDL) complete all as specified and directed. 63 Repair/servicing to DG set any make/modal 50/62.5/83 KVA water cooled diesel engine by taking out dismantling segregation of all parts and re-assembling after duly repair/ replacement of following new part fixing including all type machine work such as turning reaming etc, washing, cleaning, greasing , wires, replacement of engine oil, gaskets, flexible coupling & all type nuts bolts washers & other minor parts as required at site and testing on completion at site complete all as specified and directed. Note:- Any other accessories found unserviceable that shall be replaced & paid under respective items of this Sch as supply only and cost of fixing for fixing of the same shall be deemded to included in the quotd rate under this item. 64 All as per item No 63.00 above but for DG Set of capacity 15-20 KVA in Cantt area complete all as specified and directed. 65 Supply only Lub oil filter element for 50/62.5/83 KVA DG Set complete all as specified and directed. 66 Supply only Lub oil filter element for 15- 20 KVA DG Set complete all as specified and directed. 67 Supply only Fuel filter element for 50/62.5/83 KVA DG Set complete all as specified and directed. 68 Supply only of Fuel filter element for 15/20 KVA DG Set complete all as specified and directed. 69 Supply only of Dry type air cleaner for 50/62.5/83 KVA DG Set complete all as specified and directed. 70 Supply only of Dry type air cleaner for 15/20 KVA DG Set complete all as specified and directed. 71 Supply only of V-Belt of fan for 20 to 83 KVA DG Set complete all as specified and directed. 72 Supply only of manual type Governor Assy for 50/62.5/83 KVA DG Set complete all as specified and directed. 73 Supply only of manual type Governor Assy for 15/20 KVA DG Set complete all as specified and directed. 74 Supply only of Starting switch of DG set up to cap 50 to 83 KVA complete all as specified and directed. 75 Supply only of Starting switch of DG set up to cap 20 KVA complete all as specified and directed. 76 M&L for replacement of complete wiring (copper multistrand cable) of DG set any capacity as directed at site including thimble screw and sleaves etc complete all as specified and directed. 77 Supply only of Gauge lube oil pressure of DG set cap 20 to 83 KVA complete all as specified and directed. 78 Supply only of Hose pipe for of DG set cap 20 to 62.5 KVA complete all as specified and directed. 79 Supply only of radiator hose pipe of DG set cap 20 to 83 KVA complete all as specified and directed. 80 Supply only of Injector assy of DG set cap 50 to 83 KVA complete all as specified and directed. 81 Supply only of Injector assy of DG set cap 20 KVA complete all as specified and directed. 82 Supply only of Clamp hose radiator of DG set complete all as specified and directed. 83 Supply only of water body of DG set 50/62.5/83 KVA complete all as specified and directed. 84 Supply only of Turbo charging kit assembly of DG set 50 to 83 KVA complete all as specified and directed. 85 Supply only of self starter 12/24 volt for DG set 50 to 83 KVA complete all as specified and directed. 86 Supply only of AVR (Anti Voltage Regulator) for DG Set of capacity 50 to 83 KVA complete all as specified and directed. 87 Supply only of AVR (Anti Voltage Regulator) for DG Set of capacity 20 KVA complete all as specified and directed. 88 Supply only of Rectifier assy comprising of 230/24/12/V step down transformer heavy duty copper wound and 24 /12 V DC full wave rectifier unit for DG set 50 to 83 KVA as site requirment complete all as specified and directed. 89 S&F in replacement of Rectifier assy comprising of 230/24/12/V step down transformer heavy duty copper wound and 24 /12 V DC full wave rectifier unit for DG set 20 KVA as site requirment complete all as specified and directed. 90 S&F in Repair/Replacement of Control Panelfactory made indoor type control cubical made out of 1.6mm thick CRCA sheet dust and vermin proof totally enclosed with front opening of 415 volts 3 -phase4 - wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 62.5 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 volts grade of suitable capacity, fuses, name plates consisting of 4 pole MCCBs 100 A and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, kW, kWH, pf, temperature, Battery voltage, etc complete all as specified and directed. 91 M&L for Repair of Control Panel (50-62.5 KVA DG set)for replacing of U/S relay,andall internal wiring including lug,thimble switches with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 volts grade of suitable capacity, fuses, name plates consisting of 3/4 pole MCCBs 100 A and Contactors of capacity as recommended by the manufacturer , detachable cable gland plates, all controls, indicators and standard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, kW, kWH, pf, temperature, Battery voltage, etc complete all as specified and directed. 92 Repair of(In line) fuel pump by dismantling and segregation all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring, governer plug etc in replacement of existing U/S parts re-assembling the pump after repair/ replacement of parts, celebration for DG set of capacity 50 to 83 KVA & testing on completion complete all as specified and directed. 93 Repair of(In line) fuel pump by dismantling and segregation all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring, governer plug etc in replacement of existing U/S parts re-assembling the pump after repair/ replacement of parts, celebration for DG set of capacity 15 to 20 KVA & testing on completion complete all as specified and directed. 94 Repair to radiator assy Cleaning washing throughly, descaling and M&L for replacement of rubber size paid and MS Nut & Bolts including brazing /repair of cooling tubeswith dismantling and segregation upper and lower chamber (tank) includingand reassembling complete incl nut, bolt, washers, & spring any type for DG set capacity 20 to 83 KVA complete all as specified and directed. 95 Cleaning decarbonishing and spray painting to DG Set canopy outside of capacity 20 KVA to 62.5 KVA including writing SM No, Srl No, Make, capacity & date of installation complete all as specified and directed. 96 Disconnecting, dismantling & repair to Dynamo with segregation of all parts supply and fix in replacement of armature field, coil, carbon brush and bearing etc reassembling complete & testing on completion complete all as specified and directed. 97 Supply and fixing in replacement of maintenance free battery 12 volt 180 AH 25 plate including battery leads and initial charging of battery complete all as specified and directed. 98 M&L for replacement of Coolant for DG set complete all as specified and directed. 99 M&L for replacement of Engine oil 20 W 40 complete all as specified and directed. 100 Supply and fix in replacement engine Hrs run meter digital type suitable to match with existing system of DG set complete all as specified and directed. 101 Supply and fixing in replacement of maintenance free battery 12 volt 150 AH 25 plate including battery leads and initial charging of battery complete all as specified and directed. 102 Disconnecting, dismantling and repair/servicing to self starter 12/24 volt and replacement of field coil, carbon brush, bush or other unserviceable parts parts and refixing and testing after completion complete all as specified and directed. 103 M&L in replacement of microprocessor digital type DG set controller of DG set capcity 50 KVA to 62.5 KVA (Make of DG set- Greaves Cotton) including connect all control wiring& programming all the parameter related to DG set at site complete all as specified and directed. 104 M&L in replacement of microprocessor digital type DG set controller of DG set capcity 15 to 20 KVA(Make of DG set- Greaves Cotton) including connect all control wiring& programming all the parameter related to DG set at site complete all as specified and directed. 105 S&F in replacement of Automaticbattery chargerAC input 230 + 10% V output DC for 12/24 volt battery current 10-15 Amp for 01 No battery at a time with digital ammeter and voltmeter complete all as specified and directed. 106 S&Fin replacement ofBattery terminal of Copper bolt type suitable for any tpe of battery complete all as specified and directed. 107 S&Fin replacement ofBattery lead of copper conductor 35 Sqmm single core fitted with suitable terminal on both side complete all as specified and directed. 108 M&L for winding of armature winding and field windingwith super enamelled copper wire of appropriate gauge incl varnishing of insulating material and heating up, testing etc for alternator ofDG set of capacity 50 to 83 KVA incl taking out the old burnt windings complete all as specified and directed. 109 M&L for winding of armature winding and field windingwith super enamelled copper wire of appropriate gauge incl varnishing of insulating material and heating up, testing etc for alternator ofDG set of capacity 15-20 KVA incl taking out the old burnt windings complete all as specified and directed. 110 M&L in replacement of flame proof asbestos rope of specified dia wrapped around the exhaust pipe complete all as specified and directed. 111 Supply poring of distilled water for maint of battries complete all as specified and directed. 112 S&F in repair MCCB 4 Pole, 415 V, Adjustable type 160 amps with breaking capacity 25 KA complete all as specified & directed. 113 S&F in repair MCCB 4 Pole, 415 V, Adjustable type 250 amps with breaking capacity 25 KA complete all as specified & directed. 114 Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 125 Amps complete all as specified and directed. 115 M&L for PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm 3 core complete all as specified and directed. 116 Repair/servicing to Retrofit Emmision Controll Device any make/modal 62.5 KVA DG Set taking out dismantling segregation of all parts and re-assembling after duly repair work such as structure, Sensor, Automation, operational & panel checks, Pneumatic Cleaning of filters & all type nuts bolts washers & other minor parts as required at site and testing on completion at site complete all as specified and directed. Note:-1) This servicing is carried out by authorised OEM Chakr innovation Private Limited. 2) NABL (National Accreditation Board of Testing and Calibration Laboratories) Testing. 117 Comprehensive maintenance of following lifts in Adm buildings COD Kanpur including checking, repairing, replacing the defective items if any, preventive maintenance, greasing, lubracating, providing necessary item reqd for up keeping the lift in working condition as per OEM recommandation complete all as specified and directed. (a) Passanger Lift (8 Passenger) Machine No- J009009 Installed at Adm block, COD KanpurMake- OTIS elevator Co (I) Ltd. (b)Passanger Lift (13 Passenger) Machine No- J009254 Installed at Adm block, COD KanpurMake- OTIS elevator Co (I) Ltd. NOTE- (i) All repair / Maint to be carried out by OEM /authorised rep of OEM. Minimum two visit in one months with OEM Rep if emergency any time called for repair. Bidder shall enter an MoU with OEM of lift for repair/services of this item. The MoU with OEM shall be submitted immediately after issue of work order/commencement of work. Non submission of MoU with OEM shall lead to cancellation of contract. (ii) Repair/maint of the lift will carried out by skilled/trained personnel under the OEM supervision. (iii) Examine peroidically all safety devices and governors of the lifts and make all customary safety tests. (iv) The necessary T&P reqd shall be arranged by the OEM/Contractor and cost of the same shall deemed to be included in the rate quoted items will be paid and measured separetly as supply only. 118 Supply only J relay OTIS Make complete all as specified & directed. 119 Supply only attached panel for OTIS Make complete all as specified & directed. 120 Supply only Transformer for OTIS Make complete all as specified & directed. 121 Supply only Choke for OTIS Make complete all as specified & directed. 122 Supply only Shaft for OTIS Make complete all as specified & directed. 123 Supply only Shaft Bearing for OTIS Make complete all as specified & directed. 124 Supply only Door Motor for OTIS Make complete all as specified & directed. 125 Supply only Gate Roller for OTIS Make complete all as specified & directed.
Contract Date: Feb 28, 2026 Contract Value : 34.55 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
Uttar Pradesh View Result →
41.
Defence #9913747 AOC
Tender For Repair/Maintenance Of Street Light Fittings Including Connected Items At Domestic Area At Afs Pathankot- 1 Taking down the Carefully unserviceable any type security lights /Hanger light/wall lights of any capaciy/size from pole/ bldgs/ walls lightand refixing after repair unsv items such as choke/lamps/ignitors/ Surge protection, drivers complete all, as specified and directed by Engineer in Charge.(Note:- (i) After completion of contract, contractor shall hand over all the security/perimeter lights conventional type in perfect running/functioning condition to the department.(ii)Contractor shall provide his authorised Cell/mobile No.and local address to contact and communicate the message for any break down and contractors rep will visit the office twice a day (0930 Hrs and 1430 Hrs) to collect the day to daycomplaints of any nature/type. (iii) Penalty for not rectifying the defect in time(within 72 hrs)will be charged to contractor and the amount of penalty @ Rs 500/- per complaint will deducted from the due payment of contract.(iv) Complaints will be treated as rectified only after users Satisfactory slip will be produced by contractor to concerned JE E/M.(iv) Cost of attending day by day complaint is included in the rate quoted under this item, no extra payment for attending complaint shall be made.(v) Old material obtained from spares replacedunder this item shall be contractors property and will be measured as per credit schedule.(vi) Cost of minor spares i.e, wirnig inside light fittng, connecting wire upto terminal box, nut bolts washers or accessories as required for fixing light on pole, connector blocks are deemed to be included in the item rate, items other than mentioned will be measured and paid seperately under respective item of work,(vii) Cost of T&P i.e, ladders, tools, brazing, welding, soldering required and transportation is deemed to be included in quoted rates(viii) Area cleaning if required within vicininty of lighing poles is to be done by contractor only and rate for area cleaning is deemed to be included in quoted rates . (X) Contractor will be take proper shutdown before repaire with communation of IPSS team / Security section for repair of perimeter lights complete all as specified and directed by Engineer-in-Charge.Note:-Items 2 to 13 supply only and fixing against Item 1 2 Supply for repair/replacement of LED outdoor driver for 45/60 W LED light complete all as specified and directed by Engineer-in-Charge. 3 Supply for repair/replacement ofLED outdoor driver for 70 to 75 W LED light complete all as specified and directed by Engineer-in-Charge. 4 Supply for repair/replacement of driver for 90 W LED flood/ street light complete all as specified and directed by Engineer-in-Charge. 5 Supply for repair/replacement ofLED outdoor driver for 120 to150 W LED flood light complete all as specified and directed by Engineer-in-Charge. 6 Supply for repair/replacement of voltage surge protection device for LED lights of wattage upto 75 W complete all as specified and directed by Engineer-in-Charge. 7 Supply for repair/replacement of voltage surge protection device for LED lights of wattage 75W to 150 W complete all as specified and directed by Engineer-in-Charge. 8 Supply for repair/replacement of street lights cable PVC insulated flexible copper conductor cable of size 2.5 Sqmm three core cut to pieces all as required, drawn into existing conduit/GI pipe of wall or pole complete all as specified and directed by Engineer-in-Charge. 9 Supply for repair/replacement ofmultifunctional digital Astro Rex3 D-21 including connecting electrically using copper conductor cable of appropriate size complete all as specified and directed by Engineer-in-Charge. 10 Supply for repair/replacement ofair break contactor 3 pole 415 volts 50 Hz AC-3 duty, current rating 50 amps (normal life) with operating coil voltage 230 volts complete all as specified and directed by Engineer-in-Charge. 11 Supply for repair/replacement ofair break contactor 3 pole 415 volts 50 Hz AC-3 duty, current rating 70 amps (normal life) with operating coil voltage 230 volts complete all as specified and directed by Engineer-in-Charge. 12 Supply for repair/replacement ofair break contactor 3 pole 415 volts 50 Hz AC-3 duty, current rating 100 amps (normal life) with operating coil voltage 230 volts complete all as specified and directed by Engineer-in-Charge. 13 Supply for repair/replacement ofAC coilsuitable for Power contactor50 to 100 Amp exciting voltage 240/415 Volt complete all as specified and directed by Engineer-in-Charge. 14 S&F in replacement offlame proof flood LED light fitting 80 watts FLP with necessary braket, clamps duly painted with two coats of aluminium paint over a coat of red oxide primer, including bolts, nuts & washers for fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. 15 S&F in replacement offlame proof flood LED light fitting 100 watts FLP with necessary braket, clamps duly painted with two coats of aluminium paint over a coat of red oxide primer, including bolts, nuts & washers for fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. 16 S&F in replacement offlame proof flood LED light fitting 120 watts FLP with necessary braket, clamps duly painted with two coats of aluminium paint over a coat of red oxide primer, including bolts, nuts & washers for fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. 17 S&F in repair pressure die-cast aluminiumIP 65 cool white road way luminaire with high power LED as Light source with 35 to 40Watt high power LED withSMD LED aray with efficiency above 100 lm/W with inbuilt surge protection upto 5 kv including with suitable GI Pipe Bracket , double clamps complete with nut boltswith pole and 2.5 sqmm 3 core copper wire multistrandfor connection from DB to Light complete all as specified and directed by Engineer-in-Charge. 18 S&F in repair pressure die-cast aluminiumIP 65 cool white road way luminaire with high power LED as Light source with 60Watt high power LEDwith inbuilt surge protection upto 5 kv including with suitable GI Pipe Bracket , double clamps complete with nut boltswith pole and 2.5 sqmm 3 core copper wire multistrandfor connection from DB to Light complete all as specified and directed by Engineer-in-Charge. 19 S&F in repair pressure die-cast aluminiumIP 65 cool white road way luminaire with high power LED as Light source with 72 Watt high power LEDwith inbuilt surge protection upto 5 kv including with suitable GI Pipe Bracket , double clamps complete with nut boltswith pole and 2.5 sqmm 3 core copper wire multistrandfor connection from DB to Light complete all as specified and directed by Engineer-in-Charge. 20 S&F in repair pressure die-cast aluminiumIP 65 cool white road way luminaire with high power LED as Light source with 90 Watt high power LEDwith inbuilt surge protection upto 5 kv including with suitable GI Pipe Bracket , double clamps complete with nut boltswith pole and 2.5 sqmm 3 core copper wire multistrandfor connection from DB to Light complete all as specified and directed by Engineer-in-Charge. 21 S&F in replacement of 2 runs of 1.5 Sqmm PVC insulated stranded copper cable including PVC cassing/capping, ceiling rose, switches mounted on PVC boxes andPVC conduit 20 mm external dia medium grade saddling on building with proper clamping all fixing arrangements etc complete all as specified and directed by Engineer-in-Charge. 22 S&F in replacment of 40 mm dia light grade GI pipe bracket 1.2 mtr long bend to shape including clamps made out of 50 x 6 mm flat iron duly painted with two coats of aluminium paint over a coat of red oxide primer, suitable size nuts, bolts and washers complete all as specified and directed by Engineer-in-Charge. 23 S&F in replacement of 32 mm dia light grade GI pipe bracket 1.2 mtr long bend to shape including clamps made out of 50 x 6 mm flat iron duly painted with two coats of aluminium paint over a coat of red oxide primer, suitable size nuts, bolts and washers etc. complete all as specified and directed by Engineer-in-Charge. 24 Cutting the tree branches/ stem all around the over head line to mainten clear distance 2 mtr all around the conductor of any size or girth and shifting it to nearest waste depot and cleaning area complete between the span of two poles length of not exc 50 mtrs complete all as specified and directed by Engineer-in-Charge. 25 Supply and laying GI tubing light grade galvanised of bore 50 mm bore laid in trenches or fixed on pole/ wall for protection of UG cable complete all as specified and directed by Engineer-in-Charge. 26 Supply and laying GI tubing light grade galvanised of bore 40 mm bore laid in trenches or fixed on pole/ wall for protection of UG cable complete all as specified and directed by Engineer-in-Charge. 27 Supply, install, connect & testing cubical outdoor type factory made double door, powder coated LT bus bar feeder pillar box for 200 amps 3ph and neutral arrangement of size 500mmx500mmx200mm with MCB 4 pole 63 to 100 A complete weather proof and verminproof conforming to IP-54 made out of 3.15 mm thick CRCA sheet including provisions for ventilation and cable termination alley all as per IS.It should be mounted on 40 x40 x 6mm angle frame with a clearance of at least 0.45mtrs above GL and 0.30mtrs below ground including required PCC for foundation and coping complete all as specified and directed by Engineer-in-Charge. 28 Scraping of old paint from the street light steel tubular pole with out removing accessories and preparationof surfaces for repainting . Repainting the pole with one coat of alternative yellow and black straps of 30 cm each upto 1.5 mtr height using synthetic enamell paint . Repainting the remaining pole and clamps GI braket etc above 1.5 mtr height by applying one coat of alumn paint complete all as specified and directed by Engineer-in-Charge. 29 Painting of street light PCC pole without removing accessories with one coat ofalternative white and black straps of 30 cm each upto 1.5 mtr height using synthetic enamell paint .Colour washing the pole above 1.5 mtr height using snowcem of approved colour including painting the steel parts i.eclamps GI bracket etc by applying one coat of aluminum paintcomplete all as specified and directed by Engineer-in-Charge. 30 Writing No of pole with letters/ figures of size not exc 30 mm with black painton a yellow circle of dia 75 mm all as required complete all as specified and directed by Engineer-in-Charge. 31 S&F PVC medium grade 20 mm conduit including complete fitting and fixture i.e. bend, elbow, suitable for fixing arrangement complete all as specified and directed by Engineer-in-Charge. 32 S&F steel 20 mm conduit including complete fitting and fixture i.e. bend, elebow, suitable for fixing arrangement complete all as specified and directed by Engineer-in-Charge. 33 M&L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in benching including whethering slightly chamfered angles and finished exposed surfaces even and smooth including necessary form work for concrete eathing pit complete all as specified and directed by Engineer-in-Charge. 34 Excavation in trenches in any type of soil not exc 1.5 Mtr in width and not exc 1.5Mtr in depth and getting outfor laying of cable complete all as specified and directed by Engineer-in-Charge. 35 Returning filling in, including spreading leveling,watering and well ramming in layers not exc 1.5cm each layer complete all as specified and directed by Engineer-in-Charge. 36 Removal of surplus soil to distance not exc 50mtr and depositing where directed at level not exc1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge. 37 M&Lfor sand cushioning to underground cable 8cm thick before laying the cable and 15 cm thick after laying, stretching and testing the cable complete all as specified and directed by Engineer-in-Charge. 38 Reuse old Sub ClassBbrickcovering protectionto the eletric cablelaiddry flat transversallyalongthe lengthof cableon sandcushioningwith widthequal to lengthof brick complete all as specified and directed by Engineer-in-Charge. 39 M&L for sub class “B” bricks laid dry flat cover the cablewith width equal to the length of cable, abutting each other for protection of cable complete all as specified and directed by Engineer-in-Charge. 40 S&F in repair pressure die-cast aluminium IP 65 cool white flood Light luminaire with 80 to 90 Watt high power LED as light source SMD LEDwith inbuilt surge protection upto 5 KVincludingcomplete with nut boltswith pole and connection wire complete all as specified and directed by Engineer-in-Charge. 41 S&F in repair pressure die-cast aluminium IP 65 cool white flood Light luminaire with 120 Watt high power LED as light source SMD LEDwith inbuilt surge protection upto 5 KVincluding with Bracket, double clamps complete with nut boltswith pole and connection wire complete all as specified and directed by Engineer-in-Charge. 42 Taking down old unserviceable LT cable any size up to185sqmm 2/3.5/4 core retrieved complete all as specified and directed by Engineer-in-Charge. 43 Relayingonly LT cable taking out aganist item passing through pipe 1100 volts grade heavey dutycable with PVCinsulated multistand alumn conductor of size6 to 185 Sqmm 2/3.5core, armoured with galvanized steel strip or wire complete all as specified and directed by Engineer-in-Charge. 44 Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 25 sq mm, 2 core including cable lugs, jointing materials GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge. 45 Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 16 sq mm, 2 coreincluding cable lugs, jointing materials GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge. 46 Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 10 sq mm, 2 coreincluding cable lugs, jointing materials etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge. 47 Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 6 sq mm, 2 coreincluding cable lugs, jointing materials GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge. 48 Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 50 sq mm, 3.5 coreincluding cable lugs, jointing materials GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge. 49 Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 70 sq mm, 3.5 core including cable lugs, jointing materials ,GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge. 50 Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 95 sq mm, 3.5 coreincluding cable lugs, jointing materials,GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge. 51 Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 120 sq mm, 3.5 coreincluding cable lugs, jointing materials,GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge. 52 Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 185 sq mm, 3.5 coreincluding cable lugs, jointing materials, GI pipeetc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge. 53 Supply/ Installing testing & commissioning of street Light Pole Box of 63 Amp single phase Two wire having two no Aluminium Bus Bar including 6 Amp SP MCB.The Box should have auto Door lock facility with magnetic lock having size 260X120X230 mm and fixed to poles/ Wall using MS strip of size 20x3mm and nuts & bolts of required size complete all as specified and directed by Engineer-in-Charge. 54 S&F 1100 volts grade heavy duty cable PVC insulated aluminiuim multistranded of size 16 Sqmmserved with inner sheathing of PVC tape and overall PVC sheathed in service connections with one twin core cable flat or circularincluding cable lugs, jointing materials ,GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge. 55 S&F 1100 volts grade heavy duty cable PVC insulated aluminiuim multistranded of size 10 Sqmmserved with inner sheathing of PVC tape and overall PVC sheathed in service connections with one twin core cable flat or circularincluding cable lugs, jointing materials, GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge. 56 S&F LT cable jointing kit for 1100 V grade cable forend boxheatshrink type joint complete with jointing material and accessories suitable for XLPE armoured Aluminium conductor cable of size 10-35Sq mm 2/3.5/4 core complete all as specified and directed by Engineer-in-Charge. 57 S&F LT cable jointing kit for 1100 V grade cable forstraight through cable heatshrink type joint complete with jointing material and accessories suitable for XLPE armoured Aluminium conductor cable of size 10-35Sq mm 2/3.5/4 core complete all as specified and directed by Engineer-in-Charge. 58 S&F LT cable jointing kit for 1100 V grade cable forend joint indoor/outdoorheatshrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured Aluminium conductor cable of size 95-240Sq mm 3.5 core complete all as specified and directed by Engineer-in-Charge. 59 S&F in replacement MCB single pole 240 volts any rating from 5 to 30 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed by Engineer-in-Charge. 60 Supply and fix in replacement MCB single pole neutral 240 volts any rating 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed by Engineer-in-Charge. 61 S&F MCCB 4 pole 415 volts with rupturing cap 16 KA , 100 Amps thermal magnetic release complete all as specified and directed by Engineer-in-Charge. 62 S&F MCCB 3 pole 415 volts with rupturing cap 16 KA 63 Amps thermal magnetic release complete all as specified and directed by Engineer-in-Charge. 63 S&Fin repair pressure die-cast aluminium IP 65 cool white flood Light luminaire with 150 Watt high power LED as light sourcewith inbuilt surge protection upto 5 KV including with bracket , double clamps complete with nut boltswith pole and connection wire complete all as specified and directed by Engineer-in-Charge. 64 Supplying, installing and commissioning ofLT feeder box, outdoor type of size 0.90mx0.60m x 0.50m, made out of MS sheet 3.15mm thick,legs made out of angle iron 40mmX40mmX6mm, 1.50m long (1.00m above ground level and 0.50m embedded in PCC (1:2:4), with openable shutter on both side (front and rear) having locking arrangement with 300 Amp rated aluminium bus bar suitable for 3 phase, 4 wire supply, drilled holes for cable connection, mounted on epoxy based post insulators and MCB SPN 63 Amps, 230 volts -04 Nos, complete all as specified and directed by Engineer-in-Charge. 65 Supplying, installing and commissioning ofLT feeder box, outdoor type of size 0.90m x 0.60m x 0.50m, made out of MS sheet 3.15mm thick,legs made out of angle iron 40mmX40mmX6mm, 1.50m long (1.00m above ground level and 0.50m embedded in PCC (1:2:4), with openable shutter on both side (front and rear) having locking arrangement with 300 Amp rated aluminium bus bar suitable for 3 phase, 4 wire supply, drilled holes for cable connection, mounted on epoxy based post insulators and MCCB 4 pole, 160 Amp, 415 volt, microprocessor release with rupturing capacity 36 KA, complete all as specified and directed by Engineer-in-Charge. 66 Supply, installation and erection in true vertical position or to be planted as strut steel tubular swaged welded poles complete with MS base plate of 6mm thick of size 300mmx300mm at bottom duly welded and MS pole cap at top, poles shall made out of ERW MS tubing conforming to IS-1161 part-II, type 410 SP -31 (9.0m long) including drilling of holes of required size and Nos for fixing of cross arms/clamps,poles shall be painted internally throughout using anti corrosive black bituminous paint conforming to IS: 158-1968 and externally painted with two coat of red oxide primer and two coats of aluminum paint for expose surfaceand two coats ofblack bituminous paint for portion embedded in concrete, painting three black/white bands at lower portion of pole each of 300mm height at 300mm spacing, writing pole no. with black paint in yellow paint circle 10cm dia at suitable height complete all as specified and directed by Engineer-in-Charge.
Contract Date: Mar 30, 2026 Contract Value : 18.34 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 8
42.
Defence #9883686 AOC
Tender For Additional / Alternator To Lt Infra Including Lt Panels And Allied Items At Afs Hasi Mara; 1 Excavation in trenches not exceeding 1.5 metre wide and not exc 1.5 metre in depth for foundation or cable trenches, shafts, wells cesspits, manholes, pier holes etc. n. exc. 10 Sqm on plan and getting out in soft/loose soil, complete all as specified and directed. 2 Removing of excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point in any type of soil, complete all as specified and directed. 3 Returning filling in incl spreading, leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil, complete all as specified and directed. 4 Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 Sqmm 3.5 core including taking down old unserviceable UG cable of any size, complete all as specified and directed. 5 All as per item No 4.00 here-in-before but size cable 240 Sqmm 3.5 core, complete all as specified and directed. 6 All as per item No 4.00 here-in-before but size cable 150 Sqmm 3.5 core, complete all as specified and directed. 7 All as per item No 4.00 here-in-before but size cable 50 Sqmm 3.5 core, complete all as specified and directed. 8 All as per item No 4.00 here-in-before but size cable 25 Sqmm 3.5 core, complete all as specified and directed. 9 S & F junction box made from SMC/FRP sheet ready made of size 370 x 270 x 210mm with aluminium bus bar of 100 Amp capacity for RYB and neutral made in suitablesize fixed inside the junction box with necessary supporting insulators steped type as per junction box OEM fixed on hylem sheet, entire assemblyfixed to pole /Wall with GI clamp 25 X 4mm with GI strip and nuts & bolts two sets alongwith inside the copping of pole /Post top including MCB SP 6 Amp 10 KA 240 V - 2 Nos, with necessary sizecopper lug/ thimbles for connecting cables from junction box to fittings, complete all as specified and directed.Note:- 1. Necessary earthworks for taking out cable loop and existing cables from octagonal security light poles including reconnection the same cable to the junction box by using suitable size lugs and thimbles etc. 2. Relaying of cable loops by using obtained Sand, Bricks/slabs etc. 10 Design, Fabrication & Testing of indoor type double door both side openable with locking handle for 250 KVA DG AMF panel (for I lab/ AOC office) of size 1825(H) x 1400(W) x 450(D)mm,made of 1.6mm thick CRCA sheet supported on 75 x 40mm U-channel base frame painted with extured powder coated paint of thickness not less than 100 microns after preparation of surface in 8 tank sheetprocess system with seimens Gray RAL-7032, Aluminum Busbar & strips current capacity is calculated using the formula :- Current Capacity (Amperes) = Cross-Sectional Area (mm2) x 0.8 A/mm*. All outgoing switchgears shall have extended strips (for Ampere rating more than 63A) or extended wires with terminals (for Ampere rating below 80A) for easy and comfortable outgoing connection. The wiring will be complete with sockets and ferrule markings. The control wiring will be done by 1.5sqmm copper wire. Internal connect on with suitable size Cu. strip/Cu. wire, complete all as specified and directed.Note:- Necessary Earthworks for taking out cable loop from trench/ duct/under ground etcincluding reconnection the same cable to the LT panel by using suitable size lugs, thimbles and cable grands etc.Complete with following accessories:-(i) MCCB 400 Amp 4P 36KA TM - 03 Nos(for main supply, generator supply and for changeover supply).(ii) Spreader link 400 Amp 4P (Both Side)(iii) 3 phase heavy duty 4 pole power contactors 400 Amps, 415 volt, 4 pole 2 NO + 2 NC conforming to IS/ IEC 60947-4-1 & IEC 60947 -4-A complete - 02 Nos.(iv) C T Coil 400/5 - 06 Nos.(v) R-2, A-2, G-2indicator lamps LED.(vi) R-2, G-2 Indicator Lamp LED.(viI) B-2 Indicator Lamp LED.(viii) DigitalMultifunction Meter 4405 - 02 Nos.(ix) MX0 22E Contactor 2NO + 2NC - 03 Nos.(x) MCB 6 Amp-32 Amp SP/DP 10KA- 01 No.(xi) Buzzer 240V/24V DC - 01 No.(xii) 12 V Auto Battery Charge w/Trickle, Boost- 01 No.(xiii) Complete with all necessary protection relays, metering and indication accessories. 11 Design, Fabrication & Testing of indoor type double door both side openable with locking handle for 160 KVA DG AMF panel (for 11 ORP) of size 1825(H) x 1400(W) x 450(D)mm,made of 1.6mm thick CRCA sheet supported on 75 x 40mm U-channel base frame painted with extured powder coated paint of thickness not less than 100 microns after preparation of surface in 8 tank sheetprocess system with seimens Gray RAL-7032, Aluminum Busbar & strips current capacity is calculated using the formula :- Current Capacity (Amperes) = Cross-Sectional Area (mm2) x 0.8 A/mm*. All outgoing switchgears shall have extended strips (for Ampere rating more than 63A) or extended wires with terminals (for Ampere rating below 80A) for easy and comfortable outgoing connection. The wiring will be complete with sockets and ferrule markings. The control wiring will be done by 1.5sqmm copper wire. Internal connect on with suitable size Cu. strip/Cu. wire, complete all as specified and directed.Note:- Necessary Earthworks for taking out cable loop from trench/ duct/under ground etcincluding reconnection the same cable to the LT panel by using suitable size lugs, thimbles and cable grands etc.Complete with following accessories:-(i) MCCB 250 Amp 4P 36KA TM - 03 Nos(for main supply, generator supply and for changeover supply).(ii) Spreader link 250 Amp 4P (Both Side)(iii) 3 phase heavy duty 4 pole power contactors 250 Amps, 415 volt, 4 pole 2 NO + 2 NC conforming to IS/ IEC 60947-4-1 & IEC 60947 -4-A complete - 02 Nos.(iv) C T Coil 400/5 - 06 Nos.(v) R-2, A-2, G-2indicator lamps LED.(vi) R-2, G-2 Indicator Lamp LED.(viI) B-2 Indicator Lamp LED.(viii) DigitalMultifunction Meter 4405 - 02 Nos.(ix) MX0 22E Contactor 2NO + 2NC - 03 Nos.(x) MCB 6 Amp-32 Amp SP/DP 10KA- 01 No.(xi) Buzzer 240V/24V DC - 01 No.(xii) 12 V Auto Battery Charge w/Trickle, Boost- 01 No.(xiii) Complete with all necessary protection relays, metering and indication accessories. 12 Design, Fabrication & Testing of indoor type double door both side openable with locking handle for 125 KVA DG AMF panel (for BOMB DUMP) of size 1625(H) x 1300(W) x 450(D)mm,made of 1.6mm thick CRCA sheet supported on 75 x 40mm U-channel base frame painted with extured powder coated paint of thickness not less than 100 microns after preparation of surface in 8 tank sheetprocess system with seimens Gray RAL-7032, Aluminum Busbar & strips current capacity is calculated using the formula :- Current Capacity (Amperes) = Cross-Sectional Area (mm2) x 0.8 A/mm*. All outgoing switchgears shall have extended strips (for Ampere rating more than 63A) or extended wires with terminals (for Ampere rating below 80A) for easy and comfortable outgoing connection. The wiring will be complete with sockets and ferrule markings. The control wiring will be done by 1.5sqmm copper wire. Internal connect on with suitable size Cu. strip/Cu. wire, complete all as specified and directed.Note:- Necessary Earthworks for taking out cable loop from trench/ duct/under ground etcincluding reconnection the same cable to the LT panel by using suitable size lugs, thimbles and cable grands etc.Complete with following accessories:-(i) MCCB 200 Amp 4P 36KA TM - 03 Nos(for main supply, generator supply and for changeover supply).(ii) Spreader link 200 Amp 4P (Both Side)(iii) 3 phase heavy duty 4 pole power contactors 200 Amps, 415 volt, 4 pole 2 NO + 2 NC conforming to IS/ IEC 60947-4-1 & IEC 60947 -4-A complete - 02 Nos.(iv) C T Coil 400/5 - 06 Nos.(v) R-2, A-2, G-2indicator lamps LED.(vi) R-2, G-2 Indicator Lamp LED.(viI) B-2 Indicator Lamp LED.(viii) DigitalMultifunction Meter 4405 - 02 Nos.(ix) MX0 22E Contactor 2NO + 2NC - 03 Nos.(x) MCB 6 Amp-32 Amp SP/DP 10KA- 01 No.(xi) Buzzer 240V/24V DC - 01 No.(xii) 12 V Auto Battery Charge w/Trickle, Boost- 01 No.(xiii) Complete with all necessary protection relays, metering and indication accessories. 13 Design, Fabrication & Testing of indoor type double door both side openable with locking handle for 35 KVA DG AMF panel (for New Pump House) of size 1625(H) x 1300(W) x 450(D)mm,made of 1.6mm thick CRCA sheet supported on 75 x 40mm U-channel base frame painted with extured powder coated paint of thickness not less than 100 microns after preparation of surface in 8 tank sheetprocess system with seimens Gray RAL-7032, Aluminum Busbar & strips current capacity is calculated using the formula :- Current Capacity (Amperes) = Cross-Sectional Area (mm2) x 0.8 A/mm*. All outgoing switchgears shall have extended strips (for Ampere rating more than 63A) or extended wires with terminals (for Ampere rating below 80A) for easy and comfortable outgoing connection. The wiring will be complete with sockets and ferrule markings. The control wiring will be done by 1.5sqmm copper wire. Internal connect on with suitable size Cu. strip/Cu. wire, complete all as specified and directed.Note:- Necessary Earthworks for taking out cable loop from trench/ duct/under ground etcincluding reconnection the same cable to the LT panel by using suitable size lugs, thimbles and cable grands etc.Complete with following accessories:-(i) MCCB 63 Amp 4P 36KA TM - 03 Nos(for main supply, generator supply and for changeover supply).(ii) Spreader link 63 Amp 4P (Both Side)(iii) 3 phase heavy duty 4 pole power contactors 63 Amps, 415 volt, 4 pole 2 NO + 2 NC conforming to IS/ IEC 60947-4-1 & IEC 60947 -4-A complete - 02 Nos.(iv) C T Coil 400/5 - 06 Nos.(v) R-2, A-2, G-2indicator lamps LED.(vi) R-2, G-2 Indicator Lamp LED.(viI) B-2 Indicator Lamp LED.(viii) DigitalMultifunction Meter 4405 - 02 Nos.(ix) MX0 22E Contactor 2NO + 2NC - 03 Nos.(x) MCB 6 Amp-32 Amp SP/DP 10KA- 01 No.(xi) Buzzer 240V/24V DC - 01 No.(xii) 12 V Auto Battery Charge w/Trickle, Boost- 01 No.(xiii) Complete with all necessary protection relays, metering and indication accessories. 14 Design, Fabrication & Testing of Outdoor type LT Panel of size 1400(H) x 1200(W) x 600(D)mm, double layer door, both side openable inner parts made of 2mm thick CRCA sheet and outer shell of 3.15mm thick CRCA sheet, having Rain canopy type-4 side slope top, supported on 50 x 50 x 6mm angle iron base frame and legs of 500mm height, painted with textured powder coated paint of thickness not less than 100 microns after preparation of surface in 8 tank sheet process system with seimens Gray RAL- 7032, Alu. Busbar & strips current capacity is calculated using the formula :- Current Capacity (Amperes) = Cross- Sectional Area (mm2)x 0.8 A/mm2.All outgoing switchgears shall have extended strips (for Ampere rating more than 63A) or extended wires with terminals (for Ampere rating below 80A) for easy and comfortable outgoing connection. The wiring will be complete with sockets and ferrule markings. The control wiring will be done by 1.5sqmm copper wire. Internal connection with suitable size Alu. strip/Cu. wire, complete all as specified and directed. (For CADMO OFFICE)Incoming:-(i) MCCB 630 A 4P 50 KA TM- 1 No(ii) Spreader link 630A 4P- 1 No(iii) Extended Rotary Handle 630A- 1 No(iv) C T Coil 630/5- 3nos(v) R Y indicator lamps LED- 2 Nos(vi) Blue Indicator Lamp LED- 1 No(vii) Digital Multifunction Meter- 1 No(viii) MCB 6A SP for meter Protection- 1 NoOutgoing:-(i) MCCB 630 A 4P 50 KA TM- 1 No(ii) Spreader link 630A 4P- 1 Noc) Extended Rotary Handle 630A- 1 No 15 Design, Fabrication & Testing of Outdoor type LT Panel of size 1400(H) x 1200(W) x 600(D)mm, double layer door, both side openable inner parts made of 2mm thick CRCA sheet and outer shell of 3.15mm thick CRCA sheet, having Rain canopy type-4 side slope top, supported on 50 x 50 x 6mm angle iron base frame and legs of 500mm height, painted with textured powder coated paint of thickness not less than 100 microns after preparation of surface in 8 tank sheet process system with seimens Gray RAL- 7032, Alu. Busbar & strips current capacity is calculated using the formula :- Current Capacity (Amperes) = Cross- Sectional Area (mm2)x 0.8 A/mm2.All outgoing switchgears shall have extended strips (for Ampere rating more than 63A) or extended wires with terminals (for Ampere rating below 80A) for easy and comfortable outgoing connection. The wiring will be complete with sockets and ferrule markings. The control wiring will be done by 1.5sqmm copper wire. Internal connection with suitable size Alu. strip/Cu. wire, complete all as specified and directed. (For Dog squard and Transmitter S/S)Incoming:-(i) MCCB 160 A 4P 36 KA TM- 1 No(ii) Spreader link 160 A 4P- 1 No(iii) Extended Rotary Handle 160 A- 1 No(iv) C T Coil 160/5- 3 Nos(v) R Y indicator lamps LED- 2 Nos(vi) Blue Indicator Lamp LED- 1 No(vii) Digital Multifunction Meter- 1 No(viii) MCB 6 A SP for meter Protection- 1 NoOutgoing:-(i) MCCB 160 A 4P 36 KA TM- 1 No(ii) Spreader link 160 A 4P- 1 Noc) Extended Rotary Handle 160 A- 1 No 16 M&L for PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping of poles, approach path, LT panel etc. including necessary formwork (as required), complete all as specified and directed. 17 Supply and laying 50mm bore HDPE pipe pipe Heavy duty ofdia conformingto IS, approved colour complete with fittings for cable protection, complete all as specified and directed. 18 M&L for earthing complete with GI earth plate electrode 60 × 60cm × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not lessthan 1.5 metres below normal ground level, connected to existing earth lead strip by means of bolts, nuts, check nuts and washers of brass or HS steel all as shown in electrical plate No. 3 connected to earthing test point and and necessary excavation and earth work PCC (1:3:6) type C-1 as earth pit with MS angle iron frame 40 x 40 x 6mm and 40mm thick pre-cast RCC (1:2:4) type B-1 cover slab size 400 x 400 x 50mm reinforced with 8mm dia TMT bar, 75mm c/c both ways including one handle made of 12mm dia including providing charcoal or coke and common salt in alternate layer of 15cm compacted thickness all around the earth electrode with funnel and 20mm bore galvanized iron watering pipe (light grade) wire mesh, copper lugs, complete in all respect, including galvanised iron earth strip 32 x 6mm, protected by 40mm bore (medium grade) galvanized iron pipe up to earthing test point as directed, incl disposal of spoil to a distance not exc. 50 mtr and necessary testing on completion, complete all as specified and as directed.Note : (i) Proper earthing pit shall be provided with pit cover.(ii) GI earth strip beyond 7.5 mtr shall be measured and paid seperately. 19 Supply and fix Thermoplastics IP 65 Busbar Panel of size internal300 x 450 x 214 mm and outer dimension 400 x 500 x 220mm suitable for 100 Ampcapacity comprises with 32 x 6mm copper bus barin accordance with IEC 61439-2 which should be shock proof and double insulated. IP65 in accordance with IEC 60529 (EN 60529), weather proof, Corrosion free, Acid & Chemical Resistant, Impact resistant, Ultra Violet resistance, made of halogen & Silicone free recyclable material, internally embedded gasket with provision for cable entry through top, bottom and sides. Impact strength IK 08 (5 joules) in accordance with EN 50298:98, should withstand Glow wire test at 750°C in accordance with IEC 60695-2-11 flame retardant, Self Extinguishing, UL subject 94, V-2. Color: Grey, RAL 7035. The OEM of the Thermoplastic enclosure and the Panel manufacturer should be same and they should confirm the Panel is in accordance with IEC 61 439-1 & 2 and Routine Test Certificate should be from OEM only and submit according to IEC 61 439-1 & 2 along with Panel. The OEM of board shall submit a copy of type twst report (ASTA certification by CPRI) of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following tests performed and passed out satisfactorily: Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Degree of Protection Clearance & Creepage Distance, Mechanical Operation, complete all as specified and as directed. Note: 1.Cable gland and gland cut out will be included in unit quoted rate.2. Theentire junction box to befixed to pole /Wall with suitable size of fasteners/GI clamps will be included in unit quoted rate.
Contract Date: Mar 25, 2026 Contract Value : 42.80 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 8
West Bengal View Result →
43.
Educational and Research Institute #9832816 AOC
PROCUREMENT OF MACHINERIES, INSTRUMENTS, TOOLS AND EQUIPMENTS ETC. RELATED TO ELECTRICAL ENGINEERING AND ELECTRONICS AND TELECOMMUNICTION ENGINEERING LABORATORIES AND WORKSHOPS OF MATHABHANGA GOVERNMENT POLYTECHNIC, MATHABHANGA, COOCH BEHAR, WEST BENGAL- 1 ANALOG ELECTRONICS LAB-I (3RD SEM) 2 50 MHz Dual Channel CRO• Automatic Measurements of Signal Parameters like .Pk-Pk, Average, Max. , Min., rms, top etc. Voltages and Frequency, Period,Width,Duty Cycle, Rise Time, Fall Rime • Waveform and Set up storage facility.• Colour Display. • Advanced features like sequential acquisition of up to 1000 trigger events should be possible.• Standard USB Host & Device Connectivity. • Standard 23 Automatic Measurement andMath Function Including FFT.• Education student Lab guide and professor slide set.DETAILED TECHNICAL SPECIFICATIONS:-a)No. Of Channels:2b)Bandwidth :50 MHzc)Maximum Input:400 V (peak ac + dc) d) Sample Rate :1 GSa/sece)Waveform Update Rate : 400 Waveforms/secf)Memory : 16 Kpts/Ch.g)Time Base : 5nsec / div. To 50 sec./div.h) Resolution : 8 bitsi) Display: 5.7 inch Colour QVGA TFT LCD Display.j)Trigger Modes: Force, Edge, and Video, Pulse width.k) Built In Interface : Standard USB 2.0 (Host and Device)l)Power Supply: 230 V AC Supply, 50 Hz. 3 Function Generatori)Itshould be a waveform / function generator which can be upgraded to an arbitrary waveform generator . It may also have the feature upgrade the frequency of operationii) Should have low harmonic distortion and jitter.DETAILED TECHNICAL SPECIFICATION:--• Frequenc : 1Hz. to 20 MHz for Sine , Square and PulseWaveforms and 1 Hz. to 20 MHz. for Noise• No. of Channels: 1• Frequency Resolution : 1Hz.• Amplitude : 1 mVpk-pk to 10 v (pk - pk) in 50 ohms. • Duty Cycle for Pulse : 0.01 % to 99.99 %• Standard Waveforms: Sine,Square,Ramp,Pulse,Triangle,•Operating Modes: Continuous,Modulate,. .• Modulation Types: AM,FM,PM,FSK,BPSK,PWM• AM : Source both Internal & External, Depth 0 to 120 %With 0.01 % resolution.• FM : Source both Internal & External, Deviation 1Hz to 15 MHz• PM: Source both Internal & External, Deviation 0 to 360 deg C.• PWM : Source both Internal & External. Deviation 0 % to 100 %.• Power Supply : 230 v,50 Hz. ac. 4 Digital MultimeterDC Voltage:400mV to 1000V , AC Voltage: 400mV to 1000V,DC Current: 4mA to 10A, AC Current: 4mA to 10A, Resistance: 100 ohm to 40Mohm, Resistance: 100 ohm to 40Mohm,Capacitance: 4nF to 200µF, Duty Cycle: 0.1% to 99.9%, Frequency: 10Hz to 10MHz, Temperature: 20oC to 750oC,Transistor Test: Yes (for NPN & PNP), Diode Test: Yes, Continuing Buzzer: Yes, Power Supply: 9V, Manual and Auto ranging,Display: 4½ Digit 5 To study the V-I characteristics of UJT Trainer kitVariable DC Power Supply 1.2V to 12V/500m,A DC Power Supply for DPM 5V/500m,A UJT (2N2646) UJT Characteristics UJT Relaxation Oscillator with two different Timing Capacitors ,DigitalMeters for Measuring Voltage and Current ,Set of Patch Chords & User Manual 6 To study the input and output characteristics and to find the h-parameters of a BJT for : —(a) C-E configuration,(b) C-C configuration,(c) C-B configurationHARDWARE SPECIFICATIONS :Dual Variable DC Power Supplies 0V to 12V/500mA and0V to 15V/500mA DC Power Supply for DPM 5V/500mAIndependent Base Limiting Resistors - 2 Nos.(low value) Independent Collector Resistor - 1 No. Transistor( NPN Type SL100) .All Inputs/Outputs through 2mm Sockets set with provision of Digital Multimeter for measuring input and output. 7 ANALOG ELECTRONICS LAB-II (4TH SEM) 8 Feedback Amplifier Trainer12 V DC supply with +/- 10%accuracy,configurable circuit,Inbuilt sine wave generator with frequency range 10 Hz to 10 KHz rangeand Amplitude variation 10mV to 4V, NPN transistor. Voltage Series & Shunt and Current Series & Shunt configurable operation. 9 Oscillator Trainer KITi) Hartley, Colpitt ,Wien Bridge Oscillator Trainer kit : i) NPN Transistor ii)On boardoscillator section,separate tank circuit (iii)Biasing Voltage :+12 V , -12 V ,+12V SMPS Adaptor provided with the trainer for power supply.Designed by considering all the safety standards. Provided with an extensive manual.Power Supply to Kit: 230VAC,50Hz, All interconnections are made using 2mm banana Patch cords 10 To determine the following characteristics of op-amp: —a) input offset voltage, b) slew rate, c) non-inverting gain, d) inverting gain e) adder, f) subtractor, g) differentiator, h) integratorandi) voltage followerTo adjust offset null, setup the closed loop amplifier using IC741 op-amp also to (a) dc gain (b) ac gain. The set complete with +/-12V DC regulated power supply with milli voltage source, Null arrangement and 2V/20V dual range digital voltmeter , In built sine wave,triangular wave & square wave Generator of1 KHz, 15V Vpp (approx.), DC Power Supply : 0 - 5 V (vary through (2No.) rotary switch for specific voltage level 11 DIGITAL ELECTRONICS LAB (3RD SEM) 12 Complete setup to implement encoder, decoder ,multiplexer andde-multiplexer5V D.C. at 100mA, IC regulated power supply,21 Input Switches for data input,IC For Multiplexing 74150 is provided on board with Combinational Circuit, IC For Demultiplexing 74154 is provided on board with Combinational Circuit, One Not Gate is provided on board using 7404 ,16 Output LEDs with driver circuit to observe the output of Multiplexer Demultiplexer, A Pulser to provide the pulses manually for triggering,230 V ±10% at 50 Hz A.C. Mains,necessary patch cords and user mannuals. 13 Complete setup to design / construct parity generator, checker andcomparatorDC Regulated Power Supply 5 VDC/150 ma,5 SPDT switches provided for selecting logic ‘1’ & logic ‘0’,2 output indicators,Sufficient no of 4mm Patch Cords for Interconnection,Power Cords 230v, 50Hz,necessary patch cords and user mannuals. 14 Complete setup to design / construct binary synchronous and asynchronous counterTrainer kit for binary Synchronous and Asynchronous counter. with power supply, display unit, patch cords, manuals and necessary IC. 15 Digital I.C TesterUniversal IC tester: 40 pin DIP ZIF socket, 50 cherry keys Key pad and 16 X 2 LCD Display, suitable for testing of Analog IC, Digital IC and 7-segment display. 16 A/D & D/A Converter TrainerFEATURESAnalog To Digital Converter• 8-bit descrete ADC•12-bit monolithic ADC IC•On-board signal generator with adjustable amplitude levels•On-board LED bank to observe digital outputs•Power supply : +5V, ±12V GND•Interconnection is provided by 2mm connectors•Experimental manualDigital To Analog Converter•8-bit binary weighted resistors DAC•8-bit ladder type D to A converter•8-bit D to A converter using monolithic IC•Simple construction using Op-Amp and resistors•Onboard switches are provided for digital pattern generation•8-bit digital inputs ranges from 00 to FF•Variable frequency counter to study the settling timeSPECIFICATIONS•8-bit binary weighted and 4-bit ladder type DAC are constructed using discrete components•8-bit monolithic DAC having settling time in the range of ns, wide power supply range, low power consumption, full scale error ± 1LSB•8-bit digital ramp ADC constructed using discrete components•12-bit monolithic ADC having conversion time in the range of μs, industry standard pin out, wide input range•8 onboard switches to provide digital inputs to DAC•8-bit counter running on external clock frequency to study settling time of DAC• Built inlow frequency clock generator•1 KHz sine wave with adjustable amplitude level•Onboard variable DC voltage source for studying unipolar and bipolar modes of ADC •12 output LEDs to observe ADC outputs•ADA operates on DC power supply (+12V,-12V,+5V and GND)•Interconnection is provided by standard 2mm connector•Extensive experimental manual is provided with the kit EXPERIMENTSAnalog To Digital Converter• To study and measure resolution of ADC•To measure the conversion time of the ADC•To study full scale adjustment for unipolar and bipolar signals•To study the working of ADC 17 NETWORK ANALYSIS LAB ( 3RD SEM) 18 To study the series and parallelresonant circuitIndependent Resistors - 3 Nos. ,Independent Capacitors - 3 Nos.,Tapped Inductance. All Inputs/Outputs through 2mm Sockets Set of Patch Chords & User ManualWITH SIGNAL GENERATOR, COUNTER, DIGITAL METERS FOR INPUT & OUTPUT and user manual 19 To test and to measure the cut –off frequencies of the following: —(a) constant k-type low pass filter;(b) constant k-type high pass filterTwo Independent Passive LC Filter Networks (LPF & HPF) All Inputs/Outputs through 2mm SocketsSet of Patch Chords & User Manual 20 To study standing wave pattern for a transmission line of finite length with:(a) open termination,(b) shorted termination andmatched termination. 2.To measure the attenuation constant and phase shift constant for matched terminationTransmission Line Trainer Features:* 30-300 Mhz sweep source with detector* Calibrated attenuator* Displays standing waves/maxima-minima on CRO* Uses actual coaxial lines rather than simulated ones.* Impedance matching.* Measures VSWR, reflection coefficient, characteristic impedance, velocity of propagation, dielectric constant and signal attenuation in TDR.* Measure parameters of 50, 75 and 300 Ohms cables* Study Time Domain Reflectometry.* Study location and nature of discontinuities,Open/short, mismatched terminations, etc.* Offers a complete view of the transmission line in analog and digital domains, which is essential for complete understanding of transmission line behavior.Technical Specifications:A. Frequency Domain AnalyzerFrequency range : 30-300 MHz typical LCD Display. Level : 100mV p-p Attenuator 50 Ohms : 0.5, 1, 2,4, 8,15 dB,Output Impedance : 50 Ohms Scope out : X-Y output to scopeB. Resistive Impedance Analyzer ,Characteristic Imp. : upto 800 ohms ,Display : LCD C. Time Domain ReflectometerPRR Short range : 10MHz typical,Pulse width : <10ns typical, PRR Long range : 100KHz typicalAmplitude : 1V nominal, Output Impedance : 50 OhmsAccessories:Lengths of 50 ohms and 75 ohms coaxial cable, 300ohms, parallel line, lossy line, Tee connectors, ,Standard load of 50and 75 ohms, Various capacitive and inductive loads, shorts, Balun 1:1 & 1:4, Operating manual, Mains cord 21 COMPUTER PROGRAMMING LANGUAGE LABORATORY (3RD SEM) 22 Computer Programming Language LaboratoryTURBO C++ Software 23 MICROPROCESSOR LAB (4TH SEM) 24 8085Microprocessor Trainer KitHigh performance 8085A CPU operating at 3 MHz.16 K powerful monitor FIRMWARE expandable to 32 K. 64 K user RAM. Expanded RAM accessible using bankWrite protect facility for RAM. 3.6 V Ni-Cad battery back up. Versatile Keyboard/Display controller using 8279. 24 highly reliable dual function keys. 6 digit seven segment LED display.Parallel I/O lines available through two 8255 chips. Serial I/O through 8251 USART, with on-board level shifters 1488,1489.Programmable communication parameters. Built-in audio cassette interface.3 channels of 16 bit timer/counters from 8253.Powerful 8085 interrupt capabilities. On-board EPROM programmer with ZIF socket for programming 2716 to7512 EPROMs and various EEPROMs. Normal and intelligent programming modes.On-board ADC,DAC, opto-isolator, reed relay and miniature speaker. On-board logic probe.Single stepping, break pointing and machine cycle single stepping facility. Monitor functions can be called through software interrupts. Large collection of application software provided. All address, data and control lines from the CPU, buffered and brought out on 50 pin connector. Additional Stepper motor of specification:Shaft type: 5 mm DCurrent rating: 1200 mA2Voltage rating: 4 VHolding torque: 44 oz·inSteps per revolution: 200Resistance: 3.3 Ohm2Inductance per phase: 2.8 mHNumber of leads: 6Lead length: 30 cm 25 Microprocessor 8086 Trainer KitINTEL 8086CPU AT 4.77 MHZ CLOCK SPEED,16KB for monitor EPROM upgradable to 64kb16KB RAM expandable to 64KBBattery backup provision for RAM upto 64KB16 x 2 (or) 20 x 4 Alphanumeric LCD display101 keys IBM compatible keyboard24 TTL I/O lines brought out to two nos., of 26 pin FRC connector1 number of standard RS232C compatible serial port brought out to a pin D type male connector.3 channel 16 bit counter/timer using 8253.Fully buffered address data and control signals terminated at a 50 pin header(VXT BUS) for interfacing VBMB seriesof experiment boards and bus expansion.8 no’s of interrupt lines are terminated at a 10 pin connector.Kit operates with a single +5V/DC supplyThe kit and the power supply are mounted on a attractive light gray color fiber glass cabinet with fiber glass top cover.Built-in line assembler & DisassemblerPowerful debugging monitor to develop user program. 26 ELEMENTARY COMMUNICATION ENGG. LAB 27 To study the amplitude modulation and demodulation Ttrainer kit Features of Amplitude Modulation and Demodulation Trainer:On-board message signal with variable Amp/Freq On Board carrier signal with variable Amp/Freq AM Modulation using MC 1496 IC Demodulation using Diode Detector and LPF,6th Order LPF,Op Amp Based Variable AmplifierInternal Power Supply +5V , +12V/ 500 mATechnical Specification :Message Signal:Sine wave Frequency 100 Hz to 2.8 KHz, Amplitude 0 to 3VCarrier Signal: Sine wave Frequency-28 KHz to 108 KHzAmplitude 2V,Modulation : Balanced ModulatorAmplifier : Op Amp BasedDemodulation : Diode Detector & LPFLow Pass Filter : 6th Order LPFSupply Voltage (Board) : +12V, +5V / DCSupply current : 100 mA (Minimum)Input Voltage : 230 V/ 50 Hz ACInterface connectors : 2mm socket 28 AM/FM Radio Receiver kitFrequency range: 400KHz ~ 1.5MHzIntermediate frequency: 455KHzInputs: RF signalOutput IF frequency: 455KHz adjustableIF filter: Dual tune LC, RF amplifier with variable gain ,Mixer (frequency converter),Local oscillator:Output Signal: Sine waveFrequency range: 400KHz ~ 1.5MHz ,Amplitude: Adjustable from 0Vpp ~ 2VppOutput impedance: 50 Ohm ,1st and 2nd IF amplifierCentral frequency: 455KHz, Load impedance: Variable R-L-CGain: 40db with automatic gain control, Diode envelope detectorDetection of the envelop with variable RC filter. Audio output:Amplifier with audio jack, Audio amplifier gain: 26Db, Receiving media :MW coil antennaFM radio receiver, Reception range: 88MHz ~ 108MHz with continuous tuningTuning circuit: Using GANG capacitorIntermediate frequency: 10.7 MHz with ceramic filterEXPERIMENTS:Study of double sideband AM reception using envelope diode detector,Study of single sideband AM reception using product detector,Study of image frequencies,Study of adjustment of receiver tuned circuits,Voice reception using DSB/ SSB AM receiver (super heterodyne receiver)Effects of switch faults FM detection output level: 77.5Vrms (typical)FM detection output distortion factor: 0.3% (typical)Audio amplifier: Gain up to 46DbReceiving media: Adjustable telescopic antennaPower supply: -12V,+12V,+5V,GNDOutput volume regulation, output load impedance of 8 OhmEXPERIMENTS AM radio receiverTo study AM radio receiverTo study of image frequencies for AMFM radio receiverTo study FM radio receiverTo measure the frequency response of Audio amplifier 29 Pulse code Modulation and Demodulation system trainerInbuilt variable DC and 1 kHz AC Modulating Signals, Facility for applying external AC or DC Modulating Signal, Modulating circuit consists of a Positive Clamper, Sample and Hold (S and H), Analog to Digital Converter (ADC), Parallel to Serial Converter and Control Signal Generator, Observation of binary coded analog information by the LED status for both Modulation and Demodulation, PCM Modulation technique using IC, Built-in Pulse Code Demodulation circuit using a Serial to Parallel Converter and Parallel Shift Register DAC, Low Pass Filter for both AC & DC, Observation of Modulated & Demodulated waveform, Provision to monitor output on CRO, Clock to be provided from the Pulse Code Modulator to Demodulator circuit, Built-in IC based DC Regulated Power Supply with indication for power ON & fuse, 4 mm Patch Cords – 4 nos, Supply required 230V, 50 Hz and 1 phase AC, Comprehensive instruction manual complete with theory and operating details. 30 Frequency Modulation andDemodulation kitFM Modulators :Audio Oscillator : Sine wave (10Vpp adjustable) Frequency (300 Hz - 3.4 KHz) FM Modulators : 3 nos. • Reactance Modulator : Carrier Frequency - 455 KHz (± 3KHz) Varactor Modulator : Carrier Frequency - 455 KHz (± 2KHz) VCO Based Modulator : Carrier Frequency - 10 KHz - 200KHz (adjustable) ,Mixer / Amplifier adjustment FM Demodulator:Detuned Resonant DetectorQuadrature DetectorFoster-Seeley DetectorRatio DetectorPhase-Locked Loop Detector (IC HEF4046 based)Phase-Locked Loop Detector (IC LM565 based), Low Pass Filter : 3.4 KHz Cut off Frequency Amplifier (with adjustable gain) 31 DPCM & ADPCM MODULATION / DEMODULATION KITDPCM & ADPCM MODULATION / DEMODULATION KITOn Board Signals:. Frequency: 500KHz, Amplitude: 0 to 4 v pp 32 CONSUMER ELECTRONICS LAB (4TH SEM) 33 Black & White TV Trainer kit with provision of fault findingSystem: CCIR-B, 625 lines, Power supply :230V Ac, 50 Hz, Regulation range170v Ac to 270v Ac.,Power consumption :70 watts,Gain Limited sensitivity:55 dB for Video & 25 dB for AudioSound output :2.0 watts maximum. Screen size :20 Diagonal. Channel :VHF 2 to 12, UHF 21 to 68,S-band and Hyper-band. Isolated shockproof chassis. Sections:Electronic tuner, VideoI.F Section, Sound I.F, Video amplifier, Horizontal oscillator, Horizontal driver and EHT, Verticaloscillator, and output, S.M.P.S power ,Controls: Volume, tone, Brightness, contrast. Distortion :10 to 15% in Live program due to expanded P.C.B. All parts are soldered on Tags on SINGLE PCB of size 19x15” with complete circuit diagramSCREEN PRINTED in different colors with FAULT CREATING FACILITIES to create more than 25 faults. Standard Accessories : 1. Frame with PCB mounting.2. Picture tube fitted in wooden cabinet 3. A Manual having 20 practical. 34 DTH TV and SET TOP BOX TRAINER KITPower supply 230 V ,50 Hz, Input frequency: KU Band, Output frequency: 950-1450 Mhz.Noise temp: 35 degree,DISH ANTENA ,LNBIF FREQUENCY: 70 MHz 35 Colour TV Trainer with provision of fault findingStandard : CCIR-B-PAL-G, 625 Lines Channels : 230, 2 - 4 VHP I (VL), 5 - 12 VHP III (VH), 12 - 100 : BAND IV & V, else : S BAND & HYPER BAND Picture Tube Size : 36 cms. Diagonal RF Input Impedance : 75 W (Ohm) 36 DIGITAL & MICROWAVE COMMUNICATION ENGG. LAB 37 Spectrum AnalyzerFrequency range:9 KHz to 26.5 GHz,Phase noise :-102dBc/Hz, Max third order dynamic range, 1 GHz: 111dB, Displayed average niose level,1GHz:-163dBm,Standard attenuator range/step:50dB/10dB,70dB/10 squaredb,Overall amplitude accuracy:+/- 0.50dB 38 Antenna Trainer 86 - 860 MHZSPECIFICATIONS:Radiation pattern plotting software• Stepper motor controlled receiver stand.Antenna Measurement System:RF Source•Source types :PLL Synthesized with integrated VCO• Frequency range :100MHz to 3GHz• Dynamic range :85dBm• Transmitted power min:-50dBm• Transmitted power max:+5dBm • Impedance :50W / SMA RF Detector• Detector type: logarithmicdetector• Frequency range : 1MHz to 8GHz• Resolution: 0.1dB• Dynamic range : 85dB (±3dB)• Noise level : -90dbm• Impedance: 50W /SMA• Representation of RF level : dBmDisplay•128x64 Graphic LCD Display with backlit. Keypad•15 Key Membrane Keypad for user entry.Stepper motor controller•1.80 Resolutions.List of Standard 22 Antenna Suppliedwith the setupWire Antenna1.Monopole Plane base ground2.Dipole (2nos.) 3.Yagi4.Folded Dipole 5.Vee Dipole6.Rectangular Loop 7.HelicalMicrostrip Antenna 1.Planar Dipole 2.Planar Monopole3.CMSA 4.TMSA5.2X1 ARRAY 6.Annular ring7.Chip Antenna8.RMSA9.RMSA- Circular PolarizedAperture Antenna 1.E- Horn2.Open ended Waveguide Rectangular Array Antenna 1.Broadside Array2.Collinear ArrayReflector Antenna 1. Corner reflectorSOFTWARE• Radiation pattern plotting and analysis software suitable for windows environment Antenna PositionerThe Transmitter and Receiver Antenna stand is made of special material which is inhert to EM frequency and it has engraved height and angle scale on It. It has facility to adjust the height and level. Universal plug and fix Antenna mounts are provided to hold the antenna assembly in vertical and horizontalorientation for co and cross polarization.ACCESSORIES • SMA (M) to SMA (M) 50W flexible cable : 02nos• USB cable ( Male A to Male B): 01no• 3 Pin 6 Amp Power chord: 01no • Manual : 01no • Software on CD: 01no EXPERIMENTS• Measure the variation of field strength /inverse square law• Prove the reciprocity theorem of antenna• Plot Radiation pattern of WIRED Antenna Omni directional antenna• Plot Radiation pattern of all Aperture Antenna• Plot Radiation pattern of all Reflector Antenna• Plot Radiation pattern of all Array Antenna• Measure co-polarization, cross polarization 39 Microwave Test Bench (KLYSTRONBased)Klystron Power Supply: Specifications:Input Voltage -230V+/- 10%, 50Hz AC, Beam supply- Voltage:200-450V continuously variable; Current:Regulation: better than 0.5% for +/-10% variation in mains supply voltage; Ripple: less than 5mV rms ,Repeller Supply -Voltage:-10V to -270V continuously variable with respect to klystron cathodeRegulation: better than 0.25% for +/-10% variation in mains supply volt , Heater Supply - 6.3V DC (regulated)Modulation- Square Wave : Frequency 500Hz to 2000Hz; Max. Amplitude- +110V peak to peak, Amplitude and frequency continuously variable; Sawtooth- Frequency 50Hz to 150Hz; Max. Amplitude- 60V peak to peak, Amplitude and frequency continuously variable.VSWR Meter: (Sensitivity: 0.2 micro Volts at a 200 ohm input impedance for full scale deflection, Noise level: At least 5 dB below full scale at rated sensitivity and maximum, bandwidth with input terminated in 100 ohms and 500 ohms for low and high respectively, A/C output : BNC Connector for amplified output, Frequency : 1000Hz +/- 10%,Power : 230 Volts AC, 50Hz, mains supply) 40 ASK / PSK / FSK Modulation And Demodulation KitFEATURES•VLSI based design •Separate component and operational area •Acrylic cover for component safety •Modular organization of circuit functions •Test points to access signals at every stage of circuit operation •Multimedia based interactive e-manual Data Simulator: Onboard 8-bit variable NRZ-L pattern,Crystal Oscillator: 32.768 MHz,Data Clock: 256 KHz,Data Format: NRZ (L),Onboard Carrier Sine Waves : 1MHz (0°), 1MHz (180°), 500 KHz (0°),Power Supply: +12V, -12V, +5V, GND. 41 Microwave Test Bench (GUNN Based)Gunn microwave test bench:Gunn Power Supply (0 - 12 Volts variable,1 Amp. Max,Modulation Frequency: 1KHz +/- 10% (900-1100 Hz),Output Connector: BNC(F) for Gunn Oscillator & TNC(F) for Pin Modulator,Modulation: Square Wave, Frequency : 500Hz to 2000Hz)• Gunn Oscillator • Isolator• PIN modulator• Variable attenuator • Detector Mount• SWR meter(Sensitivity: 0.2 micro Volts at a 200 ohm input impedance for full scale deflection, Noise level: At least 5 dB below full scale at rated sensitivity and maximum, bandwidth with input terminated in 100 ohms and 500 ohms for low and high respectively, A/C output : BNC Connector for amplified output, Frequency : 1000Hz +/- 10%,Powe : 230 Volts AC, 50Hz, mains supply) 42 1 GHz spectrum Analyser1 GHz spectrum Analyser with tracking generatorFrequency range: 150 KHz to 1000 MHzFreqency Resolution: 1 KHz CF entry 40 Hz sweep resolution at 2 KHz per Division,Frequency Display: 61/2 digitFrqency Control: Digital Phase LockResolution Bandwidth: 3 KHz, 30 KHz, 220 KHz, 4 MHz. 43 INDUSTRIAL ELECTRONICS LAB -I (5TH SEM) 44 Trainer Kit to study Reverse Recovery Characteristics of Power DiodesThe single Board trainer Kit should contain IC Regulated Power Supply, Different types power diodes, Digital Ammeter and Voltmeter and other necessary passive components 45 To study drive circuit of SCRIsolated 230 V/40 W AC Power Supply1.2 V to + 15 V/500 mA DC Power Supply* 0-18 V/500 mA,50 Hz, AC Power Supply* Variable frequency triggering pulses* DC Gate signal control, Pulse gate signal * Synchronous AC gate control signal through DIAC* UJT Triggering* 10:1 On- board resistive attenuator * Provision for 40 W Lamp Load* Set of Patch Chords & userManual. 46 To study a single phase rectifier—output waveform with phase control circuitTrainer Kit to study Single Phase Full wave Bridge Rectifier for fixedDC output, Half Controlled and fully controlled rectification facilities with R and RL, loads 1000 Ohms 10 Watts, 14 ma @ 0.05 A inductive loads.The Single Board Trainer Kit contains :(i) Source for rectification of 4 to 24 V DC fixed and variable output @ a max of 500 ma helps to construct and study Series and Parallel resonance Circuit.(ii) Four Diodes and 4 SCRs in bridge configuration with gradual firing controls and necessary capacitive, inductive and Pie filter components.(iii) Digital Ammeter and Voltmeter. 47 To study a polyphase rectifierIsolated 230 V/40 W AC Power Supply Isolated stepped down 3 PH supply. * 3 Phase diode rectifier in open condition*Provision for Load& CRO output.* Electronic phase sequence finder.*Set of Patch Chords & user Manual 48 INDUSTRIAL ELECTRONICS LAB-II (6TH SEM) 49 Servo Regulator Stabilizer Study Kit500VA Servo stabilizer , 2 Amp Variac, Digital input & output meters, Lamp load, Set of Patch Chords & userManual. 50 To study a Jones chopperIsolated 230 V/40 W DC Power Supply, + 5 V/500 mA DC Power Supply* SCR Jones chopper* Gate firing pulses for Jones Chopper* 10:1 On-board Resistive Attenuator* Provision for 40 W Lamp Load* Set of Patch Chords & userManual. 51 To study speed control of induction motor by voltage and frequency variationV/F CONTROLLER 1 HP, AC SQ. CAGE IND. MOTOR 1 HP,DIGITAL VOLT & AMMETER. 1 PHASE I/P & 3 PHASE O/P,3 PH & 1PH MCB PROTECTION 52 To study the speed control of DC motor by:(a) varying field current keeping armature voltage constant; and,(b) varying armature voltage keeping field current constant DC SHUNT MOTOR (FULL COPPER WINDING) .5 HP WITH BASE MOUNT FRAME 1 No VARIAC CONTROLLED 2 DC POWER SUPPLY ( 1 FOR FIELD & 1 FOR ARMATURE)DC VOLT & AMMETER DIGITAL………4 NosPANEL MOUNTED RPM METER………1 No.WHITE BAKELITE FRONT WITH CONN. DIAGRAM & WOODEN SAFETY BOX.METAL FRAME TABLE (Ply board with sun mica) CUM STAND FOR PANEL 53 Power Electronics Devices Trainer KitShould have Built in power supplyDC supply : +/- 12V, 500mA,Power supply 17V / 750mA,Regulated 13.5V/3A O/P mustbe provided as 12V Battery charging supply. Isolated DC supply +12V/ 300mA with isolated common.On board Inverter transformer of Primary : 230V & Secondaries 12-11-0-11-12/3AOn board Lamp load of 15W (100W) should be provided.AC supply : 230V AC line voltage must be made available on two banana 4mm socketsMust have Two pulse transformers of 1:1:1 are provided for isolation & supplying firing pulsesalong with required DC Power supply to experiment panel under test through 15 pin female ‘D’connector.R-L-C Load PanelMust have Load resistor of 10W / 40W --- 1no.Must have Centre tapped 3A choke 4mH/ 16mH each ----2nos.Must have Commutation capacitors of 10mF/100V -------4nos.Must have AC Paper capacitor of 4mF/440V ---1no. 54 PLC Trainer (EXPERIMENT 1-Use of simulation package for different function of PLC. EXPERIMENT 2- Verify function of logic gates by using PLC. EXPERIMENT 3- Write and verify ladder program for motor ON-OFF Control with two push button)HARDWARE SPECIFICATION:TTL Input Switches : 8 Nos,TTL Momentary Switches : 8 Nos., Proximity Switch : 1 No.,Optical Transducer (two state) : 1 No., Programmable LEDs : 8 Nos., Analog input 0 to 5V DC : 8 channels, Analog output 0 to 5V DC : 1 No., 4 to 20mA Transmitter : 1No., 4 to 20mA Receiver : 1No., Current Meter : 25mA FSD 1No.,Voltmeter : 10V FSD 1 No., Piezo Electric Alarm : 1 bit.Built-in power supply.Dedicated I/O interface card suitable for IBM computer suitable for ISA slot. SOFTWARE SPECIFICATION:This is a GUI based LADDER LOGIC SOFTWAREDRAG AND DROP (D&D) an instruction instead of typing an instruction. This eliminates errors in typing. All the instructions are displayed ON-SCREEN during Design time. Each and every element is directly addressed with their NAMES not by numbers or codes, which are very difficult to remember. Ex: At design time, you call a SWITCH#0 in your Ladder program by D&D the component called SWITCH#0, and that’s it, not by typing a few digits numbers or codes.Appropriate LIST boxes (input, output) open as you D&D an instruction in LADDER WORKSPACE.Ladder workspace is 24X100 instruction CELLs are available for your use.TOOL TIP features are available at the end of each instruction prompting you “what to do next”Very user friendly.Extensive ON-LINE HELP menu available.GUI based STATUS of the entire PLC is displayed during RUN TIME.Programs are saved, retrieved, edited by simply clicking on Menu list box.Extensive EDIT features are available. 55 Power Electronics Development TrainerSize of Breadboard : 172.5 mm × 128.5mmDC Power Supply :+5 V, -5 V 500 mA,+12V, -12 V 500 mA+15 V, 250 mA+35V, -35V, 250 mAAC Power Supply :18V-0V-18V ,0V-15VOn board Firing CircuitsFrequency range : 30Hz to 900Hz variableAmplitude : 12VPWM control of G1, G2, G3 and G4Duty cycle control of “Gate”Signal is 0 to 100%SCR Assembly : 4 SCRs 2P4M, 400V/2APower Devices : IGBT-G4BC20S, MOSFETIRFZ44N,UJT-2N2646, DIACDB3,TRIAC-BT136, PUT-2N6027Circuit Components on board : Electrolytic Capacitor 10µF, 63V,Electrolytic Capacitor 1µF, 63V ,Met. Capacitor 0.33µF, 63V ,Diode 1N4007, Inductor 220uH, 4.7µH, 10mH.Pulse transformer on board :2 nos. PT4502 1:1 and one is PT4503 1:1:1Load selector : 6 load resistances- 47E/7W,1K/1W, 1K/10W, 10K/10W,120E/5W, 2K2/2W.Test points : 10 nos (Gold plated)Power Supply (Mains) : 220V/110V, 50Hz/60HzIncluded Accessories :Bread boards : 2 nos.Connecting wires : 20 nos.2mm to 1mm Patch cords : 15 nos.2mm Patch cords (Red) 16” : 4 nos.2mm Patch cords (Black)16’’ : 4 nos.2mm Patch cords (Blue) 16’’ : 12 nos.Mains cord : 1 no.with i) Power Semiconductor Application Experiment Panel ii)CON / INV Panel iii)Triggering circuit / dv/dt Protection panel 56 ELECTRICAL & ELECTRONICS MEASUREMENT LAB (6TH SEM) 57 Digital LCR meterVariable measured- L,C,R and loss angle (D factor ) Measured frequencies: 1 KHz, 100KHzDisplay: 3⅟₂ digit , Resistance: 0 to 20 MΩ, 0.1 Ω , Capacitance: 0 to 20000μF, 0.1 pF Inductance: 0 to 20000 H, 0.1μH ,D factor: 0.01 to 8.0 with 1% error 58 Distortion Factor MeterFrequency : 20 Hz to 200KHz Distortion:0.1% to 100% f.s.d. in steps ,Input sensitivity: 100mV (r.m.s.), Input impedance: 1MΩ/160pF, Voltmeter range: 300μv to 300v f.s.d. in 13 range 59 To measure L & Q by Maxwell methodFULL BRIDGE WITH OSCILLATOR, LED NULL BAR GRAPH & AUDIO AMPR WITH SPEAKER INBUILT FOR NULL IND., DIGITAL MULTIMETER & CRO SIG. O/P INBUILT, IMPORTED (BOURNA) 10 TURN POT FOR NULL ADJ., DECADE INDUCTANCE WITH ROTARY SWITCH INBUILT, BACKLIGHT LED & WOODEN HARD BOX 60 To measure the unknown capacitance by Schering bridgeFULL BRIDGE WITH OSCILLATOR, LED NULL BAR GRAPH & AUDIO AMPR WITH SPEAKER INBUILT FOR NULL IND., DIGITAL MULTIMETER & CRO SIG. O/P INBUILT, IMPORTED (BOURNA) 10 TURN POT FOR NULL ADJ., DECADE INDUCTANCE WITH ROTARY SWITCH INBUILT, BACKLIGHT LED & WOODEN HARD BOX 61 To measure the unknown frequency by Wein BridgeFULL BRIDGE WITH OSCILLATOR, LED NULL BAR GRAPH & AUDIO AMPR WITH SPEAKER INBUILT FOR NULL IND., DIGITAL MULTIMETER WITH FREQ. COUNTER & CRO SIG. O/P INBUILT& CRO SIG. O/P INBUILT, IMPORTED (BOURNA) 10 TURN POT FOR NULL ADJ., BACKLIGHT LED & WOODEN HARD BOX 62 MICROCONTROLLER AND EMBEDDED LAB (5TH SEM) 63 Microcontroller Trainer Kit 1.Write a Simple Assembly Programs fora. Addition b. Subtraction b. Multiplication d. Division2. Write a Programs for (any two of the following)i. 4 x 4 Matrix Keypad Interfaceii. character based LCD Interfaceiii. Analog to Digital Conversion (On chip ADC)iv. Serial EEPROMv. Seven Segment LED Display Interfacevi. Interfacing With Temperature Sensorvii. Stepper Motor Interface8 BIT EMBEDDED MICROCONTROLLER TRAINERFEATURES•Single board design with various resources•Excellent training platform for embedded applications•Software development tools include assembler and ‘C’ compiler•Easy adaptability to different versions of microcontroller in the same family SPECIFICATIONS•Experimental board for 40 pin MCS51 and AVR family of microcontrollers•In-system programming (ISP) facility for many microcontrollers•Double RESET signal with manual key•Crystal frequency: 11.0592MHz•On-board RS232 compatible serial interface terminated in a 9 Pin D female connector•4×4 matrix keyboard•16×2 alphanumeric LCD connector (4-bit interface) and trimmer for contrast adjustment•Four 7-segment LED displays•I2C EEPROM (24Cxx)•Real time clock (DS1307) with lithium battery and SRAM•8-high current output port (500mA) for driving external loads•Two 12V sugar cube relays•Continuous tone piezo buzzer•Temperature sensor socket with thermostat functions•Four 8-bit A/D converter, one 8-bit D/A converter provided by PCF8591•All port-pins available on 10-pin box header•8 LEDs for easy logic state monitoring•8 input trigger switches using 8 push buttons•ISP programming with Flash ISP for AT89S51/52/8252/AVR•Infrared remote control receiver module IC supported•P89V51RD2BN•AT89S52 Installable software on CD•Programmers notepad : Free, open source, text editor•Flash ISP programmer software for 89SXX•Bascom basic compiler (demo version)•MIDE-51: An IDE for MCS-51 microcontroller•WinAVR : open source C compiler for AVR•Sample programs for peripherals DC 12V/500mA output power supplyEXPERIMENTS• Study of LED blink• Study of dancing light• Study of LCD display• Study of LCD-keyboard display• Study of 7 –segment display• Study of RC5 remote control test program• Study of analog to digital converter• Study of real time clock (RTC) 64 ADVANCE COMMUNICATION ENGINEERING LAB 65 To be familiar with the following network components:THIS WILL BE A FULL PACKAGE OF THE FOLLOWINGS:-** RJ5/CAT5CABLES 100 METERSRJ 45CONNECTORS 100 PCSCUTTER & CRIMPING TOOLS FOR RJ45/CAT-5CABLESCABLE TESTER/TRACKER…….. 4 PCSHUBS WITH ACCESSORIES & TOOL KIT NETWORK INTERFACE DIFFERENT CARD 66 COMPUTER NETWORK LAB 67 Network ComponentsCAT 5/5E/6 cable :100mtrs (Rs 2000/-), RJ 45 Connectors: 200pcs (Rs. 500/- )RJ 45 Crimping Tools: 05(Rs. 800/- each)LAN Cable Tester (RJ 45): 05 (Rs 1000/- each) 68 24 Port managed switchNo. of Ports: 10/100 Mbps 24 Ethernet ports, Switch Fabric: 32 Gbps, Form Factor: Rack Mountable,OS: LAN base Image, Console port: Availavble for configuration, Mac Address table: 4000 or higher, VLAN: Supported, MTU: 9100 with support for jumbo frames, Warranty: 3 years onsite comprehensive warranty including parts and labor plus onsite technical support with 24x7 69 24 Port Unmanaged switch24-port 10/100/1000Mbps Ethernet switch Wifi Router: 300 Mbps wireless router with 4 LAN ports and 1 WAN port 70 8 port HubExternal Power Supply, 8 Nos RJ-45 connectors for 10BASE-T/100BASE-TX,Ethernet Ports 8-Port, Capacity 1.6 Gbps, Wireless Speed 10 / 100 Mbps 71 Access points54 Mbps Access point for wifi network: No.of Channel: Dual channel for support upto 108 Mbps ( 2x54Mbps), Backbone connectivity: connect over Fast Ethernet through backbone switches, Security: Security enabled Wifi connectivity with option for Broadcast of SSID,Network:802.11 a/b/g/n network support, PoE: PoE enabled, Form factor: Wall or ceilling mountable with physical lock suppor. Warranty and support: 3 years on site comprehensive warranty including parts and labour plus on site technical support with 24 X 7 72 LAN TrainerEthernet (IEEE 802.3 wireless LAN (802.11),Token bus ( 802.4) Token ring ( 802.5), Data rate : 10/100 Mbps for ethernet, 1, 2, 5.5, 11 Mbps for wirless & LAN as per IEEE 802.11b, connectivity through RJ 45 connector. 73 Installation & commissioning of network(i) Laying ofOFC & CAT 6 Cable (ii) splicing (iii) Installation & network testing 74 INSTRUMENTATION AND CONTROL LAB (6th sem) 75 To measure displacement with LVDT ACTUAL LVDT WITHINSTRUMENTATION AMPLIFIERDC O/P WITH DIGITAL METER, 3and 1/2 digit LED display with polarity indicator, sensitivity of 10mV/mm in the range of 10mm. 76 To measure temperature with thermocoupleTHERMOCOUPLE SENSOR IN STEEL CASEELECTRIC WATER JAG.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR MERCURY THERMOMETER 77 To measure temperature with thermistorTHERMOCOUPLE SENSOR IN STEEL CASEELECTRIC WATER JAG.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR MERCURY THERMOMETER 78 To measure pressure with strain gauge STRAIN GAUGE SENSOR WITH WAIGHT LOADING SYSYTEM SAMPLE WEIGHTS.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR 79 To plot the Characteristics of RTD (PT-100)RTD 3 WAIR SENSOR IN STEEL CASEELECTRIC WATER JAG.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR MERCURY THERMOMETER 80 Temperature controller with on-off controller, Temperature controller with PI controller, Temperature controller with PID controllerTemperature controller with facilities for P, I, D and relay control blocks, Operating temperature: Ambient to 90°C, Separate controls for P, I, D channel gains,Two settings for relay hysteresis, Fast 25W oven fitted with IC temperature sensor, Forced cooling option to ready oven for next experiment, Digital display of set and measured temperature on a 3½ digit built-in DVM, 0-9999 sec, timer on panel for a convenient temperature response experiment, Buffered output for recorder 81 CIRCUIT THEORY LAB 82 Determine the permeability of magnetic material by plotting its B-H curveHysteresis Loop Tracer/ BH Curve apparatus220volt AC, 50Hz supply 83 Series parallel resonance of R-L-C cktKit for Series parallel resonance of R-L-C ckt: The Set-up consist of Power supply (with variable frequency), audio oscillator with digital readout, digital RMS meters and different number of inductors (smoothly variable), capacitors, Rheostat, patch cord & manual. 84 SWITCH GEAR LAB 85 Speed control of Induction motor 1ph by using SCR3Φ, 400V ac, 50HZ.,1HP, 1440 rpm. Speed control using ac back to back configuration of SCRs and to note Speed vs. Load Characteristics at open loop condition. This unit should consist of AC 3Φ Induction Motor (1HP) coupled with a (i) DC Shunt Generator (1HP) for loading and (ii) a DC Tachogenerator to be used for speed feedback control. A DC meter must be provided for displaying the speed of the motor from the Tachogenerator with suitable AC Ammeter and Voltmeter for the measurement (AE Make Panel Type or digital) Sheet Metal enclosure with powder coating paint must be provided. (with foundation & Experiment Table) 86 C.T. & P.T. testing trainer kit C.T. & P.T.testing trainer kit - Variable AC voltage source (0-220V)& variable AC current source (0-25A), CT for 25/5A, PT for 220/110V, Autotransformer for voltage & current adjustment, MCB protection, To determine Ratio error, Phase angle error of CT & PT, with Burden box. , polarity check indicator , range selector switch. 87 Induction type electromagnetic relay* Over Current (IDMTL Electro- Mechanical Type , Model CDG-11 or equivalent) Relay,*PSM, TSM setting* Auxiliary Relay,* Counter /Timer,* D.W. Transformer, * Variac,* Knife Switch,* DC power supply for DC auxiliary relay and the relay,* Portable Ammeter.Necessary panel for the complete set up with wooden (teak wood) table (4x3x2.5) 88 Air Circuit BreakerCut section model 89 Transmission line protection simulation KitOver Current, Earth Fault, Over Voltage, Under Voltage, Directional, Differential, Distance protection 90 POWER PLANT LAB 91 Diesel generator power plantmodel of small diesel generator power plant 92 Hydro power plantmodel of micro Hydro power plant 93 Horizontal axis small wind turbinemodel 94 CSP plantmodel 95 MEASUREMENT LAB 96 Kelvin double bridgeCompletely self contained, stand alone unit with built in power supply, required meters, Standard Resistance, wooden bench, high sensitivity spot light type galvanometer, connecting patch chords and operating manuals. 97 RENEWABLE ENERGY LAB 98 Renewable Energy Labsolar PV plant- Model 99 Renewable Energy Labvertical axis small wind turbine- Model 100 ELECTRIC MACHINE LAB 101 VoltmeterVoltmeter (M.I type) 0-150V/300V/500V 102 VoltmeterVoltmeter (M.I type) 0-20V/50V 103 AmmeterAmmeter (M.I type) 0-5A/10A/20A 104 AmmeterAmmeter (M.I type) 0-1A/2A/5A 105 MultimeterAnalog Multi-meter of ISI marked: DC : 0-200 mV/ 1000 V & 0- 2mA – 10 A,AC : 0 – 200mV/1000V &0-2 mA – 20 A, Resistance : 0 – 200 Megaohm, with shock proof protection & other facilities and operatingmanuals. 106 MultimeterDigital Multi-meter of ISI marked: DC : 0-200 mV – 1000 V & 0-2mA – 10 A,AC : 0 – 1000 V & 0- 2mA– 20 A, Resistance : 0 – 200 Megaohm, with diodetesting, data hold, shock proof protection , auto power off etcfacilities and operating manuals. 107 WattmeterDynamometer Wattmeterof ISI marked : Low Power Factor ( 0.2 ) : Current Rating : 5/10 A , Voltage Rating : 150/300 / 600 V , with anti-parallax mirror , 120 mm scale length , knife edge pointer, mouldedBakelite body, portable. 108 VoltmeterVoltmeter (PMMC type) 0-150V/300V 109 AmmeterAmmeter (PMMC type) 0-2A/5A 110 StarterDC 3-point Starter : 220 V DC , 15 A 111 StarterDC 4-point Starter : 220 V DC , 15 A 112 DC Power SupplyDC Power Supply : Input : 415V, #-Phase AC, 50 Hz;Output : 220V DC , 5 KW of a standard make . 113 RheostatRheostat with sliding Jockey : 100 Ohm , 5 A 114 RheostatRheostat with sliding Jockey : 500 Ohm , 5 A 115 Digital Energy MeterDigital Energy Meter of ISI marked: Three Phase AC , 440 V , Maximum 30 A, 50 Hz with operatingmanual. 116 Digital MeggerDigital Megger for measuring insulation resistance of ISI marked: 250 / 500 V, Maximum 200 Mega ohmwith operating manual 117 VariacSingle Phase Variac of ISI marked : Input:– 230 V AC, Output : 0 – 270 V AC , 1 KVA, 50 Hzof a standard make 118 VariacThree Phase Variac of ISI marked : Input:– 415 V AC, Output : 0 – 500 V AC , 3 KVA, 50 Hzof a standard make 119 Clamp on MeterClamp on Meter of ISI marked : Digital type : For measuring Voltage ( AC/DC ), Current ( AC/DC ) , resistance, Power & Power Factor with operating manuals 120 Phase Sequence IndicatorPhase Sequence Indicator of ISI marked : 50 – 500 V AC, 25 – 60 Hz 121 Frequency MeterFrequency Meter of ISI marked: Digital Type : 240 V, 47 – 99 Hz 122 TransformerSingle-Phase Transformer : 1 KVA , 230 V/115V , 50 Hz( Air Cooled) 123 TransformerThree-Phase Transformer : 3 KVA , 415/230 V , 50 Hz 124 3-Ph Resistive LoadThree phase resistive load : 400 V , 6 KW 125 3-Ph Inductive LoadThree phase inductive load : 400 V , 3 KW 126 3-Ph Capacitive LoadThree phase capacitive load : 400 V , 3 KW 127 3-Ph StarterStar Delta automatic starter for 3 Phase,400 V, 5 Hpmotor 128 3-Ph DOL StarterDOL & Auto -Transformer Starter : 3-phase AC , 400V, 10A, 50 Hz 129 StroboscopeDigital Stroboscope - 10,000 rpm 130 DCGenerator Voltage build UPSupply, Installation , Commissioning & Testing with suitable ISI markedammeter, voltmeter, starter, rheostat , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :For Building up Voltage in DC Generator ( Open Circuit / Saturation Characteristics: DC Shunt Motor of ISI marked : 2HP or 5HP, 220 V. Machines will have to be set on M.S.Channel base with suitable footing/fixtures and screws etc. and operating manual isalso must.(with foundation & Experiment Table) 131 Brake test in DC Series Motor Supply, Installation , Commissioning & Testing with suitable ISI markedammeter, voltmeter, starter, rheostat , digital tachometer , Spring balance & loadings, protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :For Brake test in DC Series Motor& load Characteristics: DC Series Motor of ISI marked : 2HP, 220 V.Machineswill have to be set on M.S.Channel base with suitable footing/ fixtures and screws etc. and operatingmanual is also must.(with foundation & Experiment Table) 132 Speed Controlof 3-Phase Squirrel cage Induction motorSupply, Installation , Commissioning & Testing with necessary & suitable ISI marked meters such as ammeter, voltmeter, frequency meter , starter, protective devices and all other accessories mounted on a standing panel board as per following specification :For Speed Controlof 3-Phase Squirrel cage Induction motorby – (i) volt /freq control method : Three phase Squirrel cage induction motor : 2HP, 400V with v/f controller.Machineswill have to be set on M.S.Channel base with suitablefooting/fixturesandscrewsetc.includingtheoperating manual.(with foundation & Experiment Table) 133 Load Test of an Alternator & % regulation at various loads with Unity Power factorSupply, Installation , Commissioning & Testing with suitable ISI marked ammeter, voltmeter, starter, star connected load , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :For Load Test of an Alternator and Determination of%-age regulation at various loads with unity power factor : DC Shunt Motor of ISI marked : 3HP, 220 V , AlternatorISI marked: 2 KVA, 415 V , 50 Hz.Machineswill have to be set on M.S.Channel base with suitable footing/fixtures and screws etc. and andoperating manual is also must.(with foundation & Experiment Table) 134 Measurement of Slip of 3-Phase induction motorSupply, Installation , Commissioning & Testing with suitable ISI marked meters such as ammeter, voltmeter, frequency meter, stroboscope etc , starter , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :Measurement of Slip of 3-Phase induction motor by –(i) Stroboscopic& (ii ) Tachometer methods and reversing the direction of rotation of the motor : Three phase squirrel cage induction motor of ISI marked: 2 HP , 415 V , 50 Hz .Machineswill have to be set on M.S.Channel base withsuitable footing/fixtures and screws etc. and and operating manual is also must.(with foundation & Experiment Table) 135 Synchronization of two 3-Phase alternatorsSupply, Installation , Commissioning & Testing with suitable ISI marked meters such as ammeter, voltmeter, frequency meter etc , starter , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification : Synchronization of 3-Phase alternator ( 2 SETS ) by– (a) Three Lamp & (b) Synchroscope Methods : DC Shunt Motors of ISI marked : 5HP, 220 V ,Alternators of ISI marked: 3 KVA, 400 V, 50 Hz.Machineswill have to be set on M.S.Channel base withsuitable footings/fixtures and screws etc. and and operating manual is also must.(with foundation & Experiment Table) 136 POWER SYSTEM LAB 137 KIT FOR STUDY OF ACTIVE & REACTIVE POWERWITH SIMULATIOL KIT & LAPTOPStudy of Active & Reactive power with simulator Kit and Laptop with appropriate software, The kit should consist of variable Inductive & Capacitive load to observe change in active & Reactive power 138 MODEL OF VARIOUS TYPES OF TURBINES USED IN POWER GENERATING STATIONSModel Piece of each type of Turbine 139 PYRANOMETERMEASUREMENT OF SOLAR RADIATION BY PYRANOMETER 140 PHOTO VOLATIC SYSTEM USED IN STREET LIGHTWITH SOLAR PLATE,PV CELL,BATTERY,CHARGER 141 STUDY OF POWER SYSTEM OF 6.6 KV/400 V SUBSTATION USED FOR A HOUSING CONPLEXMODEL 142 D.C NETWORK ANALYSERD.C NETWORK ANALYSER FOR STUDY OF DIFFERENT TYPES OF FAULTS 143 DIFFERENT TYPE OF EXCITATIONS SYSTEM USED IN ALTERNATORSTATIC EXCITER,SHAFT MOUNTED,ROTATNG TYPE EXCITER & Brushless exciter ( Model only) 144 MISCELLANEOUS 145 MOTOR-ALTERNATOR SET FOR SYNCHRONISATION OF TWO ALTERNATOR WITH SYCHRONISING PANEL INCLUDING CHECK SYNCHROSCOPE & BULB ARRANGEMENT TO PERFORM TWO BRIGHT ONE DARK LAMP METHOD1.TWO SET OF D.C MOTOR 2.5 KW,230 VOLT,3000 R.P.M WITH SPEED CONTROL ARRANGEMENT 2. TWO SET OF 1 KVA,3 PHASE,440 VOLT,3000 R.P.M ALTERNATOR WITH BASE MOUNTING & EXCITATION SYSTEM. 146 PlierPlier of good quality 147 TesterTester Screwdriver of reputed brand 148 Screwdriver setScrewdriver set of reputed brand
Contract Date: Mar 12, 2026 Contract Value : 33.87 Lakh
Government Departments No of Bidders 9
West Bengal View Result →
44.
Home Affairs #9813330 Price Bid
Tender for Annual Tender For Purchase Of Computer Peripherals & It Related Spares And Consumables For The Year 2026-2027 At Ccw, Wb. , Multi Function Monochrome Laserjet Printer (Hp 4104Dw) , Multi Function Monochrome Laserjet Printer (Canon Mf3010) , Multi Function Monochrome Laserjet Printer (Hp Mf1188nw) , Multi Function Monochrome Laserjet Printer (Hp Mfp323dnw) , All-In-One Colour Printer (Epson L5290 ) , Hp Toner Cartidge No. 206A (Black) , Hp Toner Cartidge No. 206A (Yellow) , Hp Toner Cartidge No. 206A (Cyan) , Hp Toner Cartidge No. 206A (Magenta) , Canon Toner Cartridge No. 7070 (Black) , Canon Toner Cartridge No. 7070 (Yellow) , Canon Toner Cartridge No. 7070 (Cyan) , Canon Toner Cartridge No. 7070 (Magenta) , Hp Toner Cartridge No. W1002yc (Black) , Hp Toner Cartridge No. 152A (Black) , Hp Ink Tank Gt51xl (Black) , Hp Ink Tank Gt52 (Colour) , Hp Toner Cartridge No. 110A (Black) , Hp Toner Cartridge No. 137A (Black) , Hp Toner Cartridge No. 88A (Black) , Hp Toner Cartridge No. 166A (Black) , Canon Toner Cartridge No. 925 (Black) , Hp Toner Cartridge No. 283 (Black) , Hp Toner Cartridge No. 12A (Black) , Hp 938 Original Ink Cartridge Colour (C,Y,M) , Hp 938 Original Ink Cartridge Black , Compatible Toner Cartridge No. 12A (Black) , Compatible Toner Cartidge No. 337A (Black) , Compatible Toner Cartidge No. 83A (Black) , Compatible Toner Cartidge No. 166A (Black) , Compatible Toner Cartidge No. 110A (Black) , Compatible Toner Cartidge No. 88A (Black) , Compatible Toner Cartidge No. 152A (Black) , Compatible Toner Cartidge No. 137A (Black) , Compatible Toner Cartidge No. 925A (Black) , Printer Drum Tn225 , Printer Drum Tn228y , Printer Drum Tn228m , Printer Drum Tn228c , Printer Drum Tn228k , Tp Link Poe Lan Switch (4 Port Minimum) , Tp Link 08 Port Unmanaged Lan Switch 1Gbps , Tp Link 16 Port Unmanaged Lan Switch 1Gbps , Tp Link 48 Port Unmanaged Lan Switch 1Gbps , Tp-Link 24-Port Gigabit Ethernet Easy Smart Switch (Tl-Sg1024de Or Similar With Tp-Link Brand) , Tp-Link Archer Tx10ub Nano Ax900 Wi-Fi 6 Bluetooth 5.3 Desktop Usb Adapter , Tp Link Omada Er605 Vpn Router , Tp-Link Archer C6 Wireless Router , Lan Udp Patch Cable (2 Meters) , Lan Udp Patch Cable (5 Meters) , Lan Udp Patch Cable (10 Meters) , Lan Udp Patch Cable (30 Meters) , Hdmi Cable (5 Meters) , Hdmi Cable (20 Meters) , Vga Cable , Vga To Hdmi Converter , Display Port To Hdmi Converter , Lan To Usb Converter , M.2 Ssd Enclosure Nvme To Usb-C 3.1 Gen2 External Toolless Transparent 2.5 Inch , Nvme To Usb C Adapter 2.5 , 2.5 Sata Ssd Casing - Type-C External Hard Drive/Case Cover , Acer Connect M4 5G Mobile Hotspot | Wifi 6 Dual Band , Usb To Lan , Lan Coupler , Cat-6 Rj-45 Cable Connector Pack Of 100 Pieces (D-Link/Tp-Link) , Usb Hub Type A (Honeywell / Portronics / Dell) , Usb Type-C Extension Cord With Lan And Hdmi (Honeywell New Launch 12-In-1 Type C Dock With Lan, Hdmi, Usb 3.0, Sd & Microsd Slots) , Usb Type-C Extention Cord With Sd Card Reader (Honeywell New Launch 5-In-1 Type C Docking Station) , Usb 3.0 Type-A Extention Cord With 4Xusb Plug-In (Honeywell Newly Launched 4-In-1 Ultra Slim Usb Hub) , Hp External Dvd Drive Rw , External Blu-Ray Drive Rw (Usb) , Blank Dvd-Rw , Blank Compact Disk (Cd) , Pen Drive Usb3.2 Type A Metalbody -16Gb (Sandisk/Lexar) , Pen Drive Usb3.2 Type A Metalbody -32Gb (Sandisk/Lexar) , Pen Drive Usb3.2 Type A Metalbody -64Gb (Sandisk/Lexar) , Pen Drive Usb3.2 Type A Metalbody -128Gb (Sandisk/Lexar) , Memorycard - Microsd Class 10 100 Mb/S - 4Gb (Sandisk/Lexar) , Memorycard - Microsd Class 10 100 Mb/S - 8Gb (Sandisk/Lexar) , Memorycard - Microsd Class 10 100 Mb/S - 16Gb (Sandisk/Lexar) , Memorycard - Microsd Class 10 100 Mb/S - 32Gb (Sandisk/Lexar) , Memorycard - Microsd Class 10 100 Mb/S - 64Gb (Sandisk/Lexar) , Memorycard - Microsd Class 10 100 Mb/S - 128Gb (Sandisk/Lexar) , Memorycard - Microsd Class 10 100 Mb/S - 512Gb (Sandisk/Lexar) , Memorycard - Microsd Class 10 100 Mb/S - 1024Gb (Sandisk/Lexar) , Memorycard - Sd Class 10 100 Mb/S - 4Gb (Sandisk/Lexar) , Memorycard - Sd Class 10 100 Mb/S - 8Gb (Sandisk/Lexar) , Memorycard - Sd Class 10 100 Mb/S - 16Gb (Sandisk/Lexar) , Memorycard - Sd Class 10 100 Mb/S - 32Gb (Sandisk/Lexar) , Memorycard - Sd Class 10 100 Mb/S - 64Gb (Sandisk/Lexar) , Memorycard - Sd Class 10 100 Mb/S - 128Gb (Sandisk/Lexar) , Memorycard - Sd Class 10 100 Mb/S - 512Gb (Sandisk/Lexar) , Memorycard - Sd Class 10 100 Mb/S - 1024Gb (Sandisk/Lexar) , External Hard Disk Drive (Hdd) Upto 5 Gb/S Usb 3.2 - 256Gb (Seagate\Wd\Lexar\Toshiba) , External Hard Disk Drive (Hdd) Upto 5 Gb/S Usb 3.2 - 512Gb (Seagate\Wd\Lexar\Toshiba) , External Hard Disk Drive (Hdd) Upto 5 Gb/S Usb 3.2 - 1Tb (Seagate\Wd\Lexar\Toshiba) , External Hard Disk Drive (Hdd) Upto 5 Gb/S Usb 3.2 - 2Tb (Seagate\Wd\Lexar\Toshiba) , External Hard Disk Drive (Hdd) Upto 5 Gb/S Usb 3.2 - 4Tb (Seagate\Wd\Lexar\Toshiba) , External Hard Disk Drive (Hdd) Upto 5 Gb/S Usb 3.2 - 8Tb (Seagate\Wd\Lexar\Toshiba) , External Hard Disk Drive (Hdd) Upto 5 Gb/S Usb 3.2 - 10Tb (Seagate\Wd\Lexar\Toshiba) , External Hard Disk Drive (Hdd) Upto 5 Gb/S Usb 3.2 - 16Tb (Seagate\Wd\Lexar\Toshiba) , Portable Ssd-1Tb (Lexar Sl200 \ Western Digital \ Seagate) , Portable Ssd-2Tb (Lexar Sl200 \ Western Digital \ Seagate) , Portable Ssd-4Tb (Lexar Sl200 \ Western Digital \ Seagate) , Portable Ssd-8Tb (Lexar Sl200 \ Western Digital \ Seagate) , Portable Ssd-16Tb(Lexar Sl200 \ Western Digital \ Seagate) , Pcie Nvme Internal Solid State Drive (Ssd) - 256Gb , Pcie Nvme Internal Solid State Drive (Ssd) - 512Gb , Pcie Nvme Internal Solid State Drive (Ssd) - 1Tb , Pcie Nvme Internal Solid State Drive (Ssd) - 2Tb , Nas Internal Hard Drive Hdd - Sata 6 Gb/S - 4Tb , Nas Internal Hard Drive Hdd - Sata 6 Gb/S - 8Tb , Nas Internal Hard Drive Hdd - Synology Ds223j 2-Bay Diskstation Nas , Corsair Elgato Cam Link 4K Usb 3.0 Broadcast Live, Record Via Dslr, 1080P60 , Paper Shredders (Amazon Basics 8-Sheet Cross Cut Paper) , Laptop Power Cable (Portronics Konnect G3 350W Laptop Power Cable, 3 Pin Type Connector, 350W Max Load Capacity, 1.2M Length) , Desktop Power Cable (Portronics Konnect G4 350W Desktop Power Cable, 3 Pin Type Connector, 350W Max Load Capacity, 1.2M Length) , Usb-C Docking Station 3 Monitors Splitter , Data Cable Usb Type C- (Fast Charging 1.5M Braided Micro Usb Cable With 480Mbps Data Sync) , Data Cable Usb Type A- (Fast Charging 1.5M Braided Micro Usb Cable With 480Mbps Data Sync) , Charging Adapter For Mobile 65W Gan Superfast Wall Charger With Type-C Cable With Pd And Multi Port (Anker/Belkin) , Amazon Basics 17-Piece Electronics Repair Screwdriver Set , Black Decker Bd40k27 4V 6.35Mm Li-Ion Cordless Screwdriver With E-Clutch 27-Piece Set , Black+Decker Bmt154c Hand Tool Kit For Home & Diy Use (154-Piece) , Apc Back-Ups Bx600c-In 600Va / 360W, 230V (Apc) , Microtek- Online Ups E2-1Kva 24V Pure Sinewave With In-Built Batteries (12V 9Ahx2) Power Backup (Apc/Microtek) , Multiplug 6-16 annual periodical maintenance With 2-Pin & 3-Pin Socket (Anchor) , 32 In 1 Laptop Cleaner Kit Laptop Cleaning Kit (Tukzer / Amazonbasic) , Plastic Keychains With Name Tag Labels And Split Rings For Seamless Key Organization , Hp Ac Power Adapter , Dell Ac Power Adapter , Acer Ac Power Adapter , Lenovo Ac Power Adapter , Extension Board (Panasonic 16A 4 Socket Extension Board 1.5 Mtr Extension Cord) , Extension Board (Panasonic 16A 4 Socket Extension Board 5 Mtr Extension Cord) , Extension Board (16A 4 Socket Extension Board 10 Mtr Extension Cord) , Laptop Speakers (Creative Pebble 2.0 Usb-Powered) , Desktop Speaker (Philips Audio Mms2625b 2.1 Channel, Bluetooth And Wired Connectivity) , Headphone With Inbuilt Mic (Sony/Hp/Jbl) , Microphone (Sennheiser E901 Boundary Layer Half Cardoid Condenser Microphone) , Webcams With Mic (Logitech Brio 100 Full Hd 1080P Webcam) , Ptz Webcam (Logitech Bcc950 Conferencecam Usb2.0 Hd 1080P, 3 Megapixel) , Ptz Webcam (Obsbot Tiny 2 4K Webcam With 1/1.5 Sensor) , Wired Keyboards (Logitech/Hp/Dell/Rapoo) , Wireless Keyboards (Logitech/Hp/Dell/Rapoo) , Wired Mouse (Logitech/Hp/Dell/Rapoo) , Wireless Mouse - (Logitech/Hp/Dell/Rapoo) , Wired Keyboards & Mouse Combo - (Logitech/Hp/Dell/Rapoo) , Wireless Keyboards & Mouse Combo - (Logitech/Hp/Dell/Rapoo) , 21 Ips Monitor (Hp/Dell/Samsung/Aoc/Benq) , 24 Ips Monitor (Hp/Dell/Samsung/Aoc/Benq) , 15.6 Portable Monitor (Msi Pro Mp161 E2)
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
West Bengal View Result →
45.
Defence #9805484 AOC
Repair And Replacement Of Internal Fitting And Fixtures At Afs Hakimpet Under Ge (Af) Hakimpet-2 S & Fin replacement 4ft 20W LED batten tubelightsurface/wall mounted with powder coated Aluminium housing, high optically efficient polycarbonate diffuser, inbuilt electronic driver duly wired upto terminal block, luminous efficiency > 100 lm/watt, surge protection upto 4kV, 440V High voltage protection, power factor > 0.95, CRI > 80 all as specifiedanddirected by the Engineer-in-charge. Model: Wipro Garnet/ Crompton Linea Pro/ Havells Endura Linear Pro / similar 3 Supply and fixingin replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 240 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete, all as specified and directed by the Engineer-in-charge 4 S&Fin replacement LED light fitting in replacement of 10 watt bulk head luminaries complete with all accessories and including connecting up with three core twisted flexible copper conductor cable of suitablesize complete all as specified and as directed by the Engineer-in-charge 5 Supply and fixing in replacement round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers as per sample, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size completeall as specified and as directed by the Engineer-in-charge. Model: Philips Ultra Slim Plus/ Havells Integra NXT/ Wipro garnet/Similar 6 Supply and fixing in replacement round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers as per sample, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-charge. Model: Philips Ultra Slim Plus/ Havells Integra NXT/ Wipro garnet/Similar 7 Supply and fixing in replacement Deep recessed downlights, 18Watt, aluminium construction EMC/EMI compliant, Ripple<5% flicker free driver, as per sample provided including connecting the same to ceiling rose with & including twin core PVC insulated and sheathed copper conductor 23/0.0076 cable including all accessories and fixing arrangement for fixing the light to roof surface all as specified and as directed by the Engineer-in-charge.Model: Philips Ultra Slim Plus/ Havells Vibe G2/ Wipro garnet/Similar 8 Supply and fixing in replacement round shape 20 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers,as per sample provided, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-charge.Model:Wipro garnet/ Crompton Star Lord/ Similar 9 Supply and fixing in replacement round shape 24 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders,as per sample provided, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-charge.Model: Havells Integra NXT/ Jaquar areva prime/Similar 10 Supply and fixingin replacement surface downlights, 18Watt, aluminium housing with heat sinkas per sample provided including connecting the same to ceiling rose with & including twin core PVC insulated and sheathed copper conductor 23/0.0076 cable including all accessories and fixing arrangement for fixing the light to roof surface all as specifiedanddirected. Model: Havells Integra NXT 11 Supply & fixing in replacement ofhigh efficacy recess luminaire suitable for armstrong/grid ceiling with high brightness LEDs and PMMA extruded diffuser giving glare free lightand good aesthetic appeal 35/36 W LED (2ft X 2ft) complete with all accessoriesincluding connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge. Model: Havells Venus Neo/Crompton super lumen tile / similar 12 Supply and fixing of surface ceiling light 24watt,dimensions 250mm x 65mm x 250mm ( L x H x W) complete all as specified and directed by the Engineer-in-charge. Model No. Philips Saturn / Crompton star stylus/ similar 13 S&F in replacement busbar plug-in box 16A, 3phase complete . Make: Legrand Cat No. 75005005 or equivalent approved make for effective working oflights/fans all as specified and directed by the Engineer-in-charge 14 S & F in replacement of louvers with suitable frame work and fixing arrangements forexhaust fan of any size sweep complete including removing the existing unserviceable one all as specified and directed by the Engineer-in-Charge. 15 Supply and fixing of fan wall mount brackets, set of 2Pcs, MS material suitable for wall fan of any type complete all as specified and directed by the Engineer-in-charge 16 Supply and laying PVC wire trunking, self-extinguishing type 100x50 mm, sheet thickness minimum 4mm including coupler plates, elbows, tees, reducers, bolts, nuts, washers and other accessories conforming to NEMA/ASTM/BIS standards complete all as specified and directed by the Engineer in charge 17 Supply and laying PVC wire trunking, self-extinguishing type 150x50 mm, sheet thickness minimum 4mm including coupler plates, elbows, tees, reducers, bolts, nuts, washers and other accessories conforming to NEMA/ASTM/BIS standards complete all as specified and directed by the Engineer in charge 18 Supply and laying PVC wire trunking, self-extinguishing type 100x100 mm, sheet thickness minimum 4mm including coupler plates, elbows, tees, reducers, bolts, nuts, washers and other accessories conforming to NEMA/ASTM/BIS standards complete all as specified and directed by the Engineer in charge 19 Supply and fixing in replacement LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection with suitable no of nuts, bolts and clamps complete all as specified and directed by Engr-in-charge 20 Material and labour for fixing of building security light bracket made out of 40mm dia medium grade GI pipe 1.5mtr long bent to required shape to illumimate the area complete all as specified and directed by the Engineer-in-charge 21 Supply and fixing of ceiling fan white canopy/fan cover suitable for all fan types, plastic, downrod mount complete all as specified and directed by the Engineer-in-charge 22 Supply and Fixin replacement offollowing items all as specified and directed by Engineer-in-Charge:- 23 a) LED driver suitable for 2x2 LED Panel of any company from 36 watt to 42 watt Make Havells/Philips/CG 24 b) LED driver suitable for LED Lights of any company from 60 watt to 100 watt Make Havells/Philips/CG 25 S & F in replacement earth plug and socket with enclosure, single pole, neutral sheet metal enclosures with a two pin, plug and socket 20Amp, 240 voltswith and including one MCB, SP, 20A, 240 Volts as per all as specified and directed. 26 S&F surface plastic boxes made of high impact plastics and metal thread inserts 3Module complete on any surface all as specified and directed by the Engineer-in-charge 27 All as per item No. 23 here-in-before but with 4 Module complete 28 All as per item No. 23 here-in-before but with 6 Module complete 29 All as per item No. 23 here-in-before but with 8 Module complete 30 All as per item No. 23 here-in-before but with 12 Module complete 31 S&F modular metal flush box 3 module complete including any civil work required to make good the disturbed surface all as specified and directed by Engr-in-charge. 32 S&F modular metal flush box 4 module complete including any civil work required to make good the disturbed surface all as specified and directed by Engr-in-charge. 33 S&F modular metal flush box 6 module complete including any civil work required to make good the disturbed surface all as specified and directed by Engr-in-charge. 34 S&F modular metal flush box 8 module complete including any civil work required to make good the disturbed surface all as specified and directed by Engr-in-charge. 35 S&F modular metal flush box 12 module complete including any civil work required to make good the disturbed surface all as specified and directed by Engr-in-charge. 36 S&F in replacement of modular cover plate white with frame complete for3 module complete all as specified and directed by Engr-in-charge. 37 S&F in replacement of modular cover plate white with frame complete for4 module complete all as specified and directed by Engr-in-charge. 38 S&F in replacement of modular cover plate white with frame complete for6 module complete all as specified and directed by Engr-in-charge. 39 S&F in replacement of modular cover plate white with frame complete for8module complete all as specified and directed by Engr-in-charge. 40 S&F in replacement of modular cover plate white with frame complete for12module complete all as specified and directed by Engr-in-charge. 41 Supply and fixing electrical panel hylam sheets 3mm thick including cutting for mounting of switches / sockets /of size required as per site requirementcomplete all as specified and directed. 42 S&F in replacement of switch piano flush type, single pole one way6 Amps 240 volts ISI marked complete all as specified and as directed. 43 S&F in replacement of bell push,flush type, 6 Amps ,240 Volts ISI marked complete. 44 S&Fin replacement of switch socket combination 2 in 1,3 pin 6 Amps, flush type, universal ,240 volts completeall as specified and as directed 45 M & L in replacement of switch socket combination 2 in 1, 3 pin , 6 Amps/16 Amps, flush type,universal,240 volts completeall as specified and as directed 46 M & L in replacement ofCall bell, ding dong, AC 240 Volts completeall as specified and as directed 47 S&F in replacement of stepped type electronic fan regulator 100 Watt, 240 Volt, 50 Hz2 module size in 5 stepsflush type complete all as specified and directed. 48 S&F in replacement ofstepped type electronic fan regulator 100 Watt, 240 Volt, 50 Hzsinglemodule size in 5 stepsflush type complete all as specified and directed. 49 S&F BLDC Fan regulator, 12 step control, 2M, High-grade, UV-stabilized polycarbonate material, compatible for all BLDC Fans complete all as specified and directed. 50 S&F of PCB controlller for BLDC ceiling fan of any type & make, stator with winding and shaft complete all as specified and directed. Note: Make shall be same as the make of fan under repair 51 S&F in replacement of switch Modular type single pole one way6 Amps 240 volts complete all as specified and as directed. 52 S&F in replacement of switch Modular type single pole one way16 Amps 240 volts complete all as specified and as directed. 53 S&F in replacement of bell push,modular type, 6 Amps ,240 Volts ISI marked complete. 54 S&Fin replacement ofsocket2 in 1,3 pin 6 Amps, modular type, universal ,240 volts completeall as specified and as directed 55 S&Fin replacement of socket 2 in 1,3 pin 16 Amps, modular type, universal ,240 volts completeall as specified and as directed 56 S&F in replacement ofstepped type electronic fan regulator 100 Watt, 240 Volt, 50 Hz2 module size in 5 stepsmodular type complete all as specified and directed. 57 S & F in replacement of batten/angle holder, PVC/Polycarbonate type with back plate, 240 V , 50 Hzsuitable for batten fittings complete all as specified and directed. 58 S&F in replacement of ceiling rose 6 A, 3 plate,PVC/polycarbonate ,insulated body 240 Volt , 50 Hz all as specified and as directed. 59 Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, lamp holders, light fittings etc removing materials and making good disturbed surfaces of walls, floors etc. including paint touch up to match with the existing surface as per site requirement complete all as specified and directed by Engr-in-Charge. 60 Taking down existing unserviceable MCCB/main switch (any type and capacity) and making good the disturbed surface of walls including paint touchup to match with the existing surfaces complete all as specified and as directed by the Engineer in charge. 61 Taking down existing unserviceable distribution board with MCBs, switch fuse unit, enclosure and making good the disturbed surface of walls including paint touchup to match with the existing surfaces complete all as specified and as directed by the Engineer in charge. 62 Taking down Existing old unserviceable submain wiring of any description /type size and removal of UNSV material from site and making good the disturbed surface of walls / ceiling so asto match with the existing finishes all as specified and as directed by the Engineer -in- charge . 63 M&L for point wiring with 1.5 Sqmm (nominal area) multi stranded copper conductor, single core, FR-LSH PVC insulated & unsheathed cable in accordance with relevant IS with proper colour coding, 1100 volts grade drawn in ISI marked MMS grade PVC conduit of dia 20mm minimum/ casing capping , 1.2 mm thick minimum, 20mm width minimum with double locking arrangement, surface type terminated in sunken type GI sheet metal flush boxes of 16 Gauge (i.e. 1.6mm thickness) including all accessories andusing 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, FR-LSH PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed for following:- NOTE FOR ITEM NO. 60,61,62, 73 TO 77 :- (i) Quoted rate shall be deemed to include the cost of cutting chases in walls / pillars /column etc. of any description for concealing the boxesto required depth & making good the disturbed surface in CM 1:4 including finishing the surface to match with the existing surface. If the building is stone masonry, diamond tools must be used to cut the surfaces.(ii) The decision of casing capping/PVC conduit rests with the Engineer-in-charge.For casing capping, screws of minimum 35x8mm and suitable plugs should be used for fixing. In case of stone walls, wooden gutties shall be grouted in wall for fixing of screws. Distance between 2 screws shall not be more than 600mm. Size of Trunking shall be correct depending on number of wires to be drawn as per SSR Part1 but not less than 20mm.(ii)Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A.(iii) The quoted rates shall be deemed to be inclusive for provision and installation of conduits, covering sunken boards/terminal boxes / junction boxes of any shape and size modular white colour cover plate with frame and modular metal flush box. All metal boxes and plates to be of the same make as the switches mentioned in this schedule. 64 a)One light point controlled by one, 1 way switch 65 b)One 3 pin 6 Amps socket point controlled by one switch on same board 66 c)One 3 pin 6 Amps socket point controlled by one switch on independent board 67 d)One ceiling fan/exhaust fan point controlled by one 1way switch 68 e)One bell point controlled by one switch 69 f)One light point controlled by two, 2 way switches 70 All as per item No. 60 here-in-before but with 2.5 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge. 71 All as per item No. 60 here-in-before but with 4 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 4 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge. 72 M&L for point wiring with 1.5 Sqmm (nominal area) multi stranded copper conductor, single core, FR-LSH PVC insulated & unsheathed cable with proper colour coding, 1100 volts grade drawn in ISI marked MMS non-metallic PVC conduit of size not less than 20mm dia conforming to IS 9537:latest, concealed type terminated in sunken type GI sheet metal flush boxes of 16 Gauge including all accessories andusing 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, FR-LSH PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed for following:- NOTE FOR ITEM NO. 63,64,65,71,72 :- (i) Quoted rate shall be deemed to include the cost of cutting chases in walls / pillars /column etc. of any description for concealing the boxes and PVC conduits to required depth & making good the disturbed surface in CM 1:4 including core cutting whwrever required and finishing the surface to match with the existing surface. If the building is stone masonry, diamond tools must be used to cut the surfaces.(ii)Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A.(iii) The quoted rates shall be deemed to be inclusive for provision and installation of conduits, covering sunken boards/terminal boxes / junction boxes of any shape and size modular white colour cover plate with frame and modular metal flush box. All metal boxes and plates to be of the same make as the switches mentioned in this schedule. 73 a)One light point controlled by one, 1 way switch 74 b)One 3 pin 6 Amps socket point controlled by one switch on same board 75 c)One 3 pin 6 Amps socket point controlled by one switch on independent board 76 d)One ceiling fan/exhaust fan point controlled by one 1way switch 77 e)One bell point controlled by one switch 78 f)One light point controlled by two, 2 way switches 79 All as per item No. 63 here-in-before but with 2.5 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge. 80 All as per item No. 63 here-in-before but with 4 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 4 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge. 81 M&L in replacement for point wiring with 1.5 sq.mm FRLSH insulated multistranded copper conductor ,1100 volts grade single core PVC insulated and unsheathed cable drawn through existing steel/PVC conduit upto 32mm including FRLSH, PVC insulated and unsheathed cable with copper conductor cable of size 1.50 sqmm as earth conductor as per proper colour codingand pressed steel terminal boxes made out of 1.6 mm thick MS sheet box with 3mm thick laminated hylam sheet fixed with cadmium plated screws for mounting switches, sockets, fan regulator, etcincluding all accesories if required making good the disturbed surfacesof walls and paint tuch up to match with the existing surfaces as per site requirement complete all as specified and directed by Engineer-in-Charge. 82 a)One light point controlled by one switch 83 b)One 3 pin 6 Amps socket point controlled by one switch on same board 84 c)One 3 pin 6 Amps socket point controlled by one switch on independent board 85 d)One ceiling fan point controlled by one switch and regulator 86 All as per item No. 66 here-in-before but with 2.5 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge. 87 All as per item No. 66 here-in-before but with 4 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 4 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge. 88 M&L for submain wiring along with earth wire with 3 x 4.0 Sqmm FRLSH insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through existing recessed/surface steel/PVC Conduit/ casing capping in wall/roof surfaces complete all as specified and directed by Engineer-in-Charge.Note: Three runs of 4.0 Sqmm copper cable shall be measured as one unit length. 89 All as per item No.69 here-in-before but with 3 x 6.0 sqmm FRLSH PVC insulated copper conductor cable complete all as specified and directed by Engineer-in-Charge.Note: Three runs of 6.0 Sqmm copper cable shall be measured as one unit length. 90 M&L for submain wiring alongwith earth wire with 3 x 4.0 Sqmm FRLSH PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including MMS PVC Conduit concealed and its all accessories of suitable size on wall/roof surfaces complete all as specified and directed by Engineer-in-Charge.Note:Three runs of 4.0 Sqmm copper cable and one run of PVC conduit shall be measured as one unit length. 91 All as per item No. 71 here-in-before but with 3 x 6.0 sqmm FRLSH PVC insulated copper conductor cable concealed complete all as specified and directed by Engineer-in-Charge.Note: Three runs of 6.0 Sqmm copper cable and one run of PVC conduit shall be measured as one unit length. 92 M&L for submain wiring alongwith earth wire with 3 x 6.0 Sqmm FRLSH PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including MMS PVC Conduit/casing capping on surface and its all accessories of suitable size on wall/roof surfaces complete all as specified and directed by Engineer-in-Charge.Note:Three runs of 6.0 Sqmm copper cable and one run of PVC conduit shall be measured as one unit length. 93 M&L for submain wiring alongwith earth wire with 3 x 10.0 Sqmm FRLSH PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including MMS PVC Conduit/casing capping on surface and its all accessories of suitable size on wall/roof surfaces complete all as specified and directed by Engineer-in-Charge.Note:Three runs of 10.0 Sqmm copper cable and one run of PVC conduit shall be measured as one unit length. 94 M&L for submain wiring alongwith earth wire with 5 x 4.0 Sqmm FRLSH PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including MMS PVC Conduit/casing capping on surface and its all accessories of suitable size on wall/roof surfaces complete all as specified and directed by Engineer-in-Charge.Note:Five runs of 4.0 Sqmm copper cable and one run of PVC conduit shall be measured as one unit length. 95 M&L for submain wiring alongwith earth wire with 5 x 6.0 Sqmm FRLSH PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including MMS PVC Conduit/casing capping on surface and its all accessories of suitable size on wall/roof surfaces complete all as specified and directed by Engineer-in-Charge.Note:Five runs of 6.0 Sqmm copper cable and one run of PVC conduit shall be measured as one unit length. 96 M&L for submain wiring alongwith earth wire with 5 x 10.0 Sqmm FRLSH PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including MMS PVC Conduit/casing capping on surface and its all accessories of suitable size on wall/roof surfaces complete all as specified and directed by Engineer-in-Charge.Note:Five runs of 10.0 Sqmm copper cable and one run of PVC conduit shall be measured as one unit length. 97 Supply and fixing/laying2 core 2.5sqmm copper flexible cable, PVC insulated and sheathed, on wall, roof, ground, pole or passing through nallah, under road including fixing to any surface with proper plugging arrangement or in ground/wall complete all as specified and directed by the Engineer in charge 98 Supply and laying 3 core 2.5sqmm copper flexible cable, PVC insulated and sheathed, on wall, roof, ground, pole or passing through nallah, under road including fixing to any surface with proper plugging arrangement or in ground/wall complete all as specified and directed by the Engineer in charge 99 Supply and laying 2 core 4sqmm copper flexible cable, PVC insulated and sheathed, on wall, roof, ground, pole or passing through nallah, under road including fixing to any surface with proper plugging arrangement or in ground/wall complete all as specified and directed by the Engineer in charge 100 Supply and laying 3 core 4sqmm copper flexible cable, PVC insulated and sheathed, on wall, roof, ground, pole or passing through nallah, under road including fixing to any surface with proper plugging arrangement or in ground/wall complete all as specified and directed by the Engineer in charge 101 Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty 2 core cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq. mm nominal cross section in service connections complete all as specified and directed by the Engineer in charge 102 Supply and fixing of electrical flexible conduit 25mm dia, dark grey/white, corrugated , including removing the existing electrical connection on either side of DBs/Switchboards/fixtures/fittings and reconnecting after running the electrical connecting wires in the conduit complete,all as specified and directed by Engineer-in-charge 103 Supply and laying Non-metallic PVC conduit MMS grade conforming to IS 9537:latest, FRLS, dia 20mm including all accessories and hardware complete all as specified and directed by the Engineer-in-charge.Note: Cost of cutting chases shall be measured and paid separately under relevant item of this schedule. 104 Supply, Install, testing & commissioning factory made CPRI approved Cubical thermoplastic polycarbonate LT panel shock, rust, dust, impact and water proof, halogen and silicon free, UV resistant with internally embedded high grade gasket made of polyurethane, IP-65 , panel of suitable size fully wired up, ready to connect load and control lines comprising the folowing complete all as specified and directed by the Engineer-in-charge:- 105 (i) incomingMCCB 100 Amp, 25 KA, 4 Pole thermal magnetic 415 Volt - 01 Nos, (ii) Outgoing MCB SPN 6-32 Amp, 10 KA 230V - 05 Nos (iii) Busbar chamber 150A 4tsrips Aluminium- 01 Set(iv) Panel should have provision and space to install five no of 1 phase electric energy meters.Electric wiring from outgoing MCBs to Electric meters to be provided with suitable size copper wire. Electric meters will be supplied by MES. Wiring from electric meter to main MCB DB will be measured separately(v) Digital Voltmeter 0-500V and inbuilt selector switch- 01No.(vi) Digital Ammeter 0-150A with inbuilt selector switch- 01No.(vii) Phase indicator neon lamps for R,Y,B -01 Set(viii) Protection MCB 6A SP- 03No.(ix) CT 150/5A-03No.(x) Danger plate- 01No.(x) Enclosure of suitable size- 01No. 106 Supply, Install, testing & commissioning factory made CPRI approved Cubical thermoplastic polycarbonate LT panel shock, rust, dust, impact and water proof, halogen and silicon free, UV resistant with internally embedded high grade gasket made of polyurethane, IP-65 , panel of suitable size fully wired up, ready to connect load and control lines comprising the folowing complete all as specified and directed by the Engineer-in-charge:- 107 (i) incomingMCCB 125 Amp, 25 KA, 4 Pole thermal magnetic 415 Volt - 01 Nos, (ii) Outgoing MCB SP 6-32 Amp, 10 KA 4 Pole 415 Volt - 14 Nos (iii) Busbar chamber 200A 4tsrips Aluminium- 01 Set(iv) Panel should have provision and space to install four no of 3 phase electric energy meters and 1no. 1phase energy meter. Electric wiring from outgoing MCBs to Electric meters to be provided with suitable size copper wire. Electric meters will be supplied by MES. Wiring from electric meter to main MCB DB will be measured separately(v) Digital Voltmeter 0-500V and inbuilt selector switch- 01No.(vi) Digital Ammeter 0-200A with inbuilt selector switch- 01No.(vii) Phase indicator neon lamps for R,Y,B -05 Sets(viii) Protection MCB 6A SP- 03No.(ix) CT 200/5A-03No.(x) Danger plate- 01No.(x) Enclosure of suitable size- 01No. 108 Supply and fixin replacement distribution board double door type TPN 8 waysheet steel powder coatedwith bus bar ,neutral link & earth bar etc. with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing cables/circuit wiring complete all as specified and directed by Engineer-in-Charge. 109 All as per item No. 87 above but of TPN 4 way. 110 Supply and fix in replacement distribution board double door type VTPN 8 waysheet steel powder coatedwith bus bar ,neutral link & earth bar etc. with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing cables/circuit wiring complete all as specified and directed by Engineer-in-Charge. 111 Supply and fixin replacement distribution board double door type VTPN 4 waysheet steel powder coated with bus bar ,neutral link & earth bar etc. with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing cables/circuit wiring complete all as specified and directed by Engineer-in-Charge. 112 Supply and fix MCB distribution board single door type SPN 12 way sheet steel powder coated with bus bar ,neutral link & earth bar etc.with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing circuit complete all as specified and directed by Engineer-in-Charge. 113 All as per item No. 91 above but of SPN 8 way. 114 All as per item No. 91 above but of SPN 4 way. 115 Supply and fixin replacement sheet metal powder coated double pole enclosure with a two pin and earth plug and socket flushing in wall including 20 Amps rated double pole MCB 10 KA, C curve complete all as specified and directed by Engineer-in-Charge. 116 Supply and fixin replacement sheet metal powder coated triple pole and neutral enclosure with a three pin and earth plug and socket flushing in wall including 32 Amps rated 415 V, three pole MCB 10 KA, C curve complete all as specified and directed by Engineer-in-Charge. 117 S&Fin replacement MCBTriple pole and Neutral (TPN) of capacity 40-100 Amps 415 volts ,breaking capacity 10 KA,C series ,fixed in proper position all as directed by the Engineer in charge . 118 Supply and fixin replacement MCB, SPN, 40-63 Amps, 240 Volts 119 Supply and fixin replacement MCB , SP, 6 - 32 Amps, 240Volts 120 Supply and fixingin replacement MCCB 125 Amp three pole 415 Volt , breaking capacity 16 KA, with fixed thermal & magnetic setting complete all as specified and as directed by the Engineer in charge. 121 Supply and fixingMCCB 25-100 Amp Three pole 415 Volt , breaking capacity, 16 KA, with fixed thermal & magnetic setting complete all as specified and as directed by the Engineer in charge. 122 Disconnecting and removing exhaust fan of any sweepany height from electrical connection bringing down, dismantling, cleaning internally and externally thoroughly and re-assembling in all respects after replacement of unserviceable parts/components provision of new flexible wire of size 23/0.0076 multistranded copper conductor cable from ceiling rose to fan includingpainting of exhaust fan complete with synthetic enamel paint by spraying including filling cavities with filler , one coat after cleaning all dust etc & testing complete all as specified and as directed.Note: Note: Spare parts replaced shall be measured and paid seperately under relevant items.However, labour cost of replacement of parts is included in unit rate quoted 123 Disconnecting and removingceiling fan of any sweepany height from electrical connection bringing down, dismantling, cleaning internally and externally thoroughly, lubricating with approved lubricants, and re-assembling in all respects after replacement of unserviceable parts/components refixing in original position includingminor repairs for the smooth functioning and provision of new flexible wire of size 23/0.0076 multistranded copper conductor cable from ceiling rose to fan includingpainting of ceiling fan complete with synthetic enamel paint by spraying including filling cavities with filler , one coat after cleaning all dust etc & testing complete all as specified and as directed.Note: Spare parts replaced shall be measured and paid seperately under relevant items.However, labour cost of replacement of parts is included in unit rate quoted 124 Supply only the following parts in replacement of Ceiling/ Exhaust Fans of existing makes and size complete all as specified and as directed by the Engineer-in Chargre :- 125 (a)Capacitor 2.5 mfd capacity 240 volts. Make: CAPCO/TIBCON 126 (b)Ball bearingof suitable size. Make: NBC/SKF/TATA. 127 (c) Gun metal bush 128 (d) Copper flexible cord 3 core of size 23/00076, 5m bundle 129 (e) Fan Clamp with rubber bush 130 (f)Down rod, 400 mm long 131 (g) Capacitor 4 mfd capacity 240 volts .Make : CAPCO/TIBCON 132 (h) Ball bearing for exhaust fans of suitable sizeMake: NBC/SKF/TATA 133 S & F in replacement of motor for plastic exhaust fan of any size and type complete all as specified and directed by the Engineer-in-Charge. 134 Taking Down water heater (Electric Geyser) storage type of any make of 25 / 50 ltr capacity after disconnecting the existing electrical connection, water pipes and reassembling in all respects after replacing unserviceable parts/components and testing for proper working after repairs and refixing in the original place/position duly connecting up water supply and electric supply etc.complete all as specified and as directed by the Engineer-in-Charge. Note :- Spare parts replaced shall be measured and paid separately under relevent items below.However labour cost of replacement is deemed to be included in the rate quoted. 135 Supply only the following parts in replacement of water heater (Electric Geyser) storage type of given make and size complete all as specified and as directed by the Engineer-in Chargre :- 136 (a) Thermostat ISI marked suitable for 25/50 litre capacity . Make -sphare hot /bajaj/ditz/picco/usha /racold . 137 (b) Heating element ISI marked 2000 watt push/thread type circular /triangular base suitable for any make and size. Make - bajaj / Racold 138 (c) Indicator bulb 240 V suitable for givenmake, typeand model 139 S & F in replacement of PVC connection 15 mm dia 450 mm long with PTMT nuts on both sides for cold water connection. 140 S & F in replacement of PVC connection 15 mm dia 900 mm long with PTMT nuts on both sides for cold water connection. 141 S & F in replacement of PVC connection 15 mm dia 450 mm long with PTMT nuts on both sides forhotwater connection. 142 S & F in replacement of PVC connection 15 mm dia 900 mm long with PTMT nuts on both sides forhotwater connection. 143 Supply only Geyser Capillary Thermostat and Cut Out, Capillary Thermostat Suitable for any Geyser 10 to 50 Liter, 230volts, copper and plastic material complete all as specified and directed by the Engineer-in-charge 144 Supply and fixing of Round sheet 5 , heavy duty PVC/ polypropylene complete all as specified and directed by Engineer-in-charge 145 Supply and fixing of Round sheet 6 heavy duty PVC/ polypropylene all as specified and directed by Engineer-in-charge 146 S & F in replacement of plug top 3 pin 6 Amps 240 volts.Make: Anchor/Leader/Havells. 147 S & F in replacement of plug top 3 pin 16 Amps 240 volts.Make: Anchor/Leader/Havells. 148 Repairing/overhauling of TPN/SPN DBs of any size/type fixed on building wallincl cleaning with compressed air, tightening of all electric connection to the bus bar& switch gears , refixing of loosed doors withproper fixing & locking arrangement & necessary welding work as required and replacement of wornout/ burnt/rusted/ loose lugs , door lock, nut bolt,hing, washers,internal wiring with suitable size (minimum 1.5 sqmm) of PVC copper conductor wire ,repair to plaster workas require at site and including disconnection of all cable/ sub main from the bus bar and insulating the naked portion ofAl/Cu conductorand re-connect the sameafter repair of panel and proper connection of main earth wire/lead with panel body using lugs complete all as specified and directed. 149 Supply and fixing concealed meter box with isolator made from minimum 0.7mm thick CRCA sheet, to accommodate 1No. Single phase energy meter complete all as specified and directed. 150 Supply and fixing concealed meter box with isolator made from minimum 0.7mm thick CRCA sheet, to accommodate 1No. Three phase energy meter complete all as specified and directed. 151 Supply and fix electric water heater, vertical storage typewith ferroglass coated anti-rust inner container and heating element upto 2 KW capacity 25 litre, heavy duty anode rod, preset thermal cutout, BEE 5 Star rated as per latest BEE norms (i.e. standing losses ≤ 0.465 kWh/24 hour/45°C which is only valid till 31st Dec 2025, material shall be supplied as per latest revision at the time of supply, complete with all accessories such as safety valve, thermostat, NRV, connection piece(hot and cold water connection pipe)etc complete all as specified and directed by Engr-in-charge (as per latest authorization). Model: Havells Monza DX or similar in Bajaj/Orient 152 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories without remote, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated as per latest BEE norms in vogue at the time of supply with brushless direct current motor (BLDC) including depositing the unserviceable ceiling fan to MES E/M store complete all as specified and directed by Engineer-in-Charge. 153 S&F in replacement post top lanterns, 25W , IP65 long life aesthetically designed with symmetrical light distribution with high power LED , clear/opaque cover as per site requirement complete all as specified and directed. 154 Supply and fix in replacement Exhaust fan, steel body AC Single phase 230 V of size 300 mm sweep with blades, and frame and louvers including taking down the existing unserviceablefan and depositing it to MES E/M Store complete all as specified and directed by Engr-in-charge 155 Supply and fix in replacement Exhaust fan, steel body AC Single phase 230 V of size 225 mm sweep with blades, and frame and louvers including taking down the existing unserviceablefan and depositing it to MES E/M Store complete all as specified and directed by Engr-in-charge 156 Supply and fix in replacement exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm including taking down the existing unserviceablefan and depositing it to MES E/M Store complete all as specified and directed 157 Supply & fixing in replacement new generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape IP 65 luminaire for diffused lighting with high power LED 8 Watts as light source with all accessoriesincluding connecting up with three core twisted flexible copper conductor cable with suitable size and fixing arrangements such as grouting with suitable nuts bolts and washers in PCC base complete all as specified and directed by Engineer-in-Charge. Make:- Havells Model No BAMBOOBLS8WLED830PSYMTOPC or equivelent in Bajaj/ Crompton/ Philips. 158 Suppy only Insulation tape all as specified and directed by Engineer-in-charge 159 S&F in replacement 400mm swing wall fan, 4star, smooth oscillation, copper motor with remote control, 72 speeds, plastic bodyincluding taking down the existing unserviceablefan and depositing it to MES E/M Store complete all as specified and directed 160 Supply and fix in replacement 12W LED T bulbs, cool day white, energy efficient, no visible flickering, glare reduction technology complete all as specified and directed 161 Supply and fxing of Cable Zip Ties Heavy Duty Strong Wire Organizer, nylon material, 8inch dia , 20cm length complete all as specified and directed by the Engineer-in-charge 162 Supply and fixing of blank plates, made of FR grade engineering plastic, for concealing vacant slots in switchboards complete all as specified and directed by the Engineer in charge 163 Supply and fixing of MCB modular blank plates, made of polycarbonate, glossy finish, rectangular type, thickness minimum 2mm complete all as specified and directed by the Engineer in charge
Contract Date: Mar 16, 2026 Contract Value : 26.41 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
46.
Home Affairs #9801859 AOC
Supply Of Misc. Goods , Misc. Goods , Acoustic Board , Acp Board , Acrylic Primerasian Paints , Acrylic Primer Berger , Acrylic Tent Card Display Stand A4 , Acrylic Two Side Display Desk Name Plate , Agronet , Air Blower Machine , Air Diffuser Machine Air Roma , Air Diffuser Machine Air Wick , Air Diffuser Refill Air Roma , Air Diffuser Refill Air Wick , Alamati , All-Out Machine , All-Out Oil (Refill) , Altarafbrass Jindal , Altaraf Aluminium Jindal , Aluminium Angle Jindal , Aluminium Bar 1X1Ilko , Aluminium Bar 1X1 Apex , Aluminium Bar 2X1 Apex , Aluminium Bar 2X1 Ilko , Aluminium Bar 2.5X 1.5Ilko , Aluminium Bar 2.5X 1.5 Apex , Aluminium Channel2 Track Apex , Aluminium Channel2 Track Ilko , Aluminium Channel3 Trackilko , Aluminium Channel3 Track Apex , Aluminium Door / Windows Without Glasssetting Ilko/ Apex , Aluminium Door/Windows With Completeglasssetting Ilko/ Apex , Aluminium Foil 9 Mtr. , Aluminium Garanchiilko/ Apex , Aluminium Glass Channelilko/ Apex , Aluminium Ladder Ilko/ Apex , Aluminium Sheet Ilko/ Apex , Aluminium Socket Ilko/ Apex , Anti Insect Net , Aquarium (Full Ready Without Fish) , Arrowrootpowder , Asbestos , Asbestos For Motka , Ash-Tray Wooden , Attache Box Safari , Attache Box Vip , Axe With Handle - 5 Kg Taparia , Axe With Handle - 5 Kg Tata , Badge For Civic Volunteers , Balloonmedium Size , Balloon Big Size , Bamboo Basket , Bamboo Fencing (Dorma) , Bamboo Full Size , Bamboo Ladder , Baral (Plastic) 40 Ltr , Barbed Wire Tata , Batali3 Jaw Taparia , Batali 1 Tata , Bedcover (Double Bed) Bombay Dyeing , Bedcover (Double Bed) Divine Lines , Bedcover (Double Bed) Raymonds , Bedcover Single - Bombay Dyeing , Bedcover Single - Divine Lines , Bedcover Single - Raymonds , Bedsheet(Single Bed) Bombay Dyeing , Bedsheet(Single Bed) Divine Lines , Bedsheet(Single Bed) Raymonds , Bedsheet (Double Bed) Bombay Dyeing , Bedsheet (Double Bed) Divine Lines , Bedsheet (Double Bed) Raymonds , Belcha Plastic Small , Belcha Tata With Handle , Bench High Wooden , Bench Low Wooden , Bhusha Kali , Bi - Cycle For Gents Bsa , Bi- Cycle For Gents Hero , Bi -Cycle For Lady Bsa , Bi- Cycle For Lady Hero , Binocular 7-35 Cf , Binocular X 35 Zoom , Bitumen , Black Board , Black Boardduster , Black Board Stand Iron , Black Oxide , Black Paper Sheet Normal Size , Black Polish Liquid Cherry 75 Ml , Black Polish Paste Cherry 40Gm , Blade For Hacksaw -Big- Tata , Blade For Hacksawsmall - Tata , Blanket (Bombaydeying) , Blanket (Raymond Home) , Blanket (Signature) , Blanket Cover (Bombaydeying) , Blanket Cover (Raymond Home) , Blanket Cover (Signature) , Blanket For Prisoner , Bleaching Powder Bengal Chemical , Bob Pliers Taparia , Body Shampoo 250Ml Dove , Body Shampoo 250Ml Nivea , Body Shampoo 400Ml Dove , Body Shampoo 400Ml Nivea , Bolt Cutter 12 Taparia , Brass Chainkasvi Classic , Brass Flower Tub 10 Kasvi Classic , Brass Flower Tub 12Kasvi Classic , Brass Flower Tub 14 Kasvi Classic , Brass Flower Tub 6 , Brass Hook2 , Brass Letter 2 , Brass Letter 3 , Brass Lock For Door Godrej , Brass Lock For Door Royel , Brass Name Plate With Engraving And Black Letter. , Brass Pipe1.5 , Brass Pipe2 , Brass Ring 1.5 , Brass Screw , Brass Stand Pole 4 , Brass Stand Pole 7.5 Ft , Brass T-Pole Stand 4 , Brasso Bowl , Brasso Dabu Hata , Brasso Dish , Brasso Fork Spoon , Brasso Glass , Brasso Jug , Brasso Khunti , Brasso Spoon Hata , Brasso Tea Spoon , Brick2 No. , Brick 1 No. , Broom Stick Coconut , Brown Polish Liquid Cherry 75Ml , Brown Polish Paste Cherry 40Gm , Brown Powder , Brush Cutter Machine Petrol 4 Stroke -Over Head Cam Single Cylinder , (2Hp) Honda , Brush Cutter Machine Petrol Fs 230 Power Output 1,55 Sthil , Brush Hard , Brush Soft , Bugle Brasso , Bugle Steel , Candle For Aqua Guard/ Water Filter , Candle Small Good Quality , Cane Basket , Car Air Freshner Refill Ambipure 7.5 Ml , Car Freshener Aer Click Godrej , Car Freshener Godrej Aer Twist , Car Freshener Oil Starter Ambipure , Car Freshener Refill Gel Godrej , Car Freshner Campure Cone60gm , Carafe Milton 1 Ltr. , Carbolic Acid (100 Ml.) , Carpet Green/ Blue/ Red , Cellotape 1 , Cellotape 2 , Cement Acc , Cement Ambuja , Cement Jafri (10X4) , Cement Jafri (7X4) , Cement Pillar 1 , Cement Pillar 5 , Cement Primer Dulax , Cement Primer Ici , Centre Table Steel With Glass Top , Centre Table Wdn Frame With Glass Top , Chain Shaw Machine Black+Decker Electric 22 , Chain Shaw Machine Black+Decker Petrol 16 , Chain Shaw Machine Sthil Electric 22 , Chain Shaw Machine Sthil Petrol 16 , Chair Cover , Chaker Tiles With Fitting , Chopping Board Plastic , Chopping Board Wooden , Climbing Rope , Coal Tar , Coffee Mug , Coffee Mug Special , Coir Mat 2 X 5 , Coir Mat 3.5 X 1.5 , Coir Rope , Colin (250 Ml) , Colin (500 Ml) , Collapsible Gate With Fitting , Colour Glass 6Mm , Comfort 1 Litrs (Unilevers) , Comfort 500Ml(Unilevers) , Comforter , Concerntina Wire With Fitting Tata , Copper Water Bottle , Corrugated Tin “Motka” Tata , Corrugated Tin Blue Scope Jindal , Corrugated Tin Blue Scope Tata , Corrugated Tin G. I. 0.45Mm.Jindal , Corrugated Tin G. I. 0.45Mm.Tata , Corrugated Tin G. I. 0.55Mm.Jindal , Corrugated Tin G. I. 0.55Mm.Tata , Corrugated Tin Motka Blue Scope Jindal , Corrugated Tin Motka Blue Scope Tata , Cotton 100 Gm Packet Each , Cotton Rope , Cup- Plate Set(6 Pcs. Set) Bone Chaina , Cup Plate Set La-O-Pala(6 Pcs. Set) , Cup Plate Set Special(6 Pcs. Set) , Curtain Cloth Roller Blind For Window , Curtain Cloth Special , Curtain Cloth Terry Cotton , Curtain Cloth Vertical Blind For Window , Cushion Chair With Arms Nilkamal , Cushion Chair With Arms Supreme , Cushion Chair Without Arms Nilkamal , Cushion Chair Without Arms Supreme , Cushion For Sofa , Cutter Chain (Chain Saw Machine) Boosch , Cutter Chain (Chain Saw Machine) Sthil , Dabu Hata Iron Tata , Dao Iron , Ddl Pidilite , Dead Body Cover Bag (7 X 3) , Decoration Chain Plastic , Decoration Flag Silk 3X15 , Decoration Flag Silk 3X2 , Decoration Flag Silk 6X4 , Dendrite Gum , Detergent Liquied 1 Ltr Sunlight , Detergent Liquied 1 Ltr Surf-Excel , Detergent Powder 1Kg Surf-Excel , Detergent Powder 500 Gm Sunlight , Detergent Powder 500 Gm Surf-Excel , Detergent Powder 5Kg Surf-Excel , Detergent Soap 200Gm Surf-Excel , Dettol Liquid 125 Ml , Dettol Liquid 500 Ltr. , Dettol Liquid 500 Ltr. Menthol Fresh , Dining Table Plastic (Square) 4Seat Supreme , Dining Table Plastic(Round Shape) 4Seat Nilkamal , Dining Table Plastic(Square) 4Seat Nilkamal , Dining Table Steel With Glassroundshape , Dining Table Steel With Glasssquare , Dining Table Wooden With Glassroundshape , Dining Table Wooden With Glasssquare , Dining Tableplastic (Round Shape) 4Seat Supreme , Dinner Plate Bone China , Dinner Set 12 Pcs. Cello , Dinner Set 12 Pcs. La-O-Pala , Dinner Set 16 Pcs. Cello , Dinner Set 16 Pcs. La-O-Pala , Dinner Set 27 Pcs. Cello , Dinner Set 27 Pcs. La-O-Pala , Dinner Set 63 Pcs. Cello , Dinner Set 63 Pcs. La-O-Pala , Dinner Set 63 Pcs. Special , Direction Board , Dispencerfor Handwash Special , Distric Unit Flag Synthetic With Embroidered (3Ft. X 4Ft.) , Distric Unit Flag Synthetic With Embroidered (6Ft. X 4Ft.) , Distric Unit Flag Velvet With Embroidered (3Ft. X 4Ft.) , Distric Unit Flag Velvet With Embroidered (6Ft. X 4Ft.) , Door Bala 4 , Door Closer Godrej , Door Closer Ozone , Door Clump Godrej , Door Frame Wooden , Door Handle Brass. Ozone , Door Handle Brass.Godrej , Door Handle Steel. Godrej , Door Handle Steel. Ozone , Door Lock Brasso Godrej , Door Lock Steel Godrej , Door Magnet Godrej , Door Mat Special , Door Mat Synthetic , Door Mat Woolen , Door Pvc With Frame Sintex , Door Pvc With Frame Supreme , Door Stopper (Brass) , Door Stopper (Steel) , Drain Brash , Drawer Channel , Drawer Nob , Drinking Water Bottle 1 Ltr Bisleri , Drinking Water Bottle 500 Ml Kinley , Drinking Water Bottle 500 Ml Bisleri , Drinking Water Bottle1 Ltr Kinley , Drinking Water Bottle2 Ltr Bisleri , Drinking Water Bottle2 Ltr Kinley , Drinking Water Jar 20 Ltr Bisleri , Drinking Water Jar 20 Ltr Local , Drinking Water Jar 5 Ltr Bisleri , Drinking Water Jar 5 Ltr Kinley , Drinking Water Pouch 300 Mlbisleri , Drinking Water Pouch 300 Mlhimalayan , Drum (Big) For Band , Drum Stick For Big Drum , Durmush 5 Kg. , Dustbin Basket (Open) Pvc , Dustbin Big Size Pvc 110 Ltr With Lid Nilkamal , Dustbin Big Size Pvc 110 Ltr With Lid Sintex , Dustbin Big Size Pvc 200 Ltr With Lid Nilkamal , Dustbin Big Size Pvc 200 Ltr With Lid Sintex , Dustbin Big Size Pvc With Wheel 200 Ltr. With Lid Nilkamal , Dustbin Big Size Pvc With Wheel 200 Ltr. With Lid Sintex , Duster Cloth Cotton (18 X 18) , Earthen Pitchers With Lid With Plastic Tap , Elastic Rubber , Electoral Powder 21.8 Gm Orange , Emery Cloth , Emery Paper , Empty Plastic Cement Bag , Ex-Search Mirror , Ezee Liquid 1 Ltr. , Ezee Liquid 500 Ml , Fevicolpidilite , Fevicol 500Gmpidilite , Fiber Dhal , Fiber Gila , Fiber Lathi , Fiber Name Plate With Letter And Colouring , Fiber Sheet , Finit Spray Gun , Fire Bucket (Iron) , Fire Extinguisherrefilling ( Foam 9 Kg) , Fire Extinguisherrefilling (Powder 1 Kg) , Fire Extinguisherrefilling (Powder 5 Kg) , Fire Extinguisherrefilling (Powder 9 Kg) , Fire Extinguisher Foam 1 Kg Abc Type Fire , Fire Extinguisher Foam 5 Kg Abc Type Fire , Fire Extinguisher Foam 9 Kg Abc Type Fire , Fire Extinguisher For Car 500 Ml , Fire Extinguisher Powder 1 Kg Abc Type Fire , Fire Extinguisher Powder 5 Kg Abc Type Fire , Fire Extinguisher Powder 9 Kgabc Type , Fire Wood , First-Aid Box With Kit , Fishes For Aquarium , Flash Door With Frame Bq , Flask Steel 1 Ltr.Cello , Flask Steel 1 Ltr. Eagle , Flask Steel 1 Ltr. Milton , Flask Steel 2 Ltr.Cello , Flask Steel 2 Ltr. Eagle , Flask Steel 2 Ltr. Milton , Flask Steel 500 Mlcello , Flask Steel 500 Ml Milton , Flask Steel 500Ml. Eagle , Flex Print Banner , Flex Print Banner With Iron Frame , Flex Print Banner With Wooden Frame , Floor Carpet (Synthetic) , Floor Cleaner (Mop) , Floor Cleaning Pocha , Floor Marble With Fitting , Floor Mat (Best Quality) , Floor Tiles Brush , Floor Tiles With Fitting , Flurosent Gum Sticker , Flurosent Jacket , Fog Machine (For Mosquito) , Folding Nylon Cot , For-Ed , Frame With Hacksaw 1/1 ½ , Funnel For Kerosenebig , Funnel For Kerosenemedium , G.I Sheetbhushan , G.I Sheettata , G.I Water Dram With Lid 40 Ltr. , G.I Water Dram With Lid 60 Ltr. , G.I Wire Swg 20 Tata , G.I Wire Swg 4 Tata , G.I Wire Swg 6 Tata , Gaitytata , Gajal Tata , Gala , Galicha , Garbage Carrybagbig , Garbage Carrybag Small , Garden Chair Cast Iron 3 Seater , Garden Chair Table Set (4 Pc + 1 Pc) , Garden Umbrella Giant , Garden Umbrella Synthetic.K.C Paul , Garden Umbrella Synthetic. Mahendra Dutta , Garden Umbrella Synthetic. Orange , Gas Lighter For Oven. , Gas Oven 2 Burner Stainless Steel Kuchina , Gas Oven 2 Burner Stainless Steel Prestige , Gas Oven Double Berner (Iron) Sunflame , Gas Oven Single Burner ( Steel) Kuchina , Gas Oven Single Burner (Iron)Sunflame , Gas Oven Single Burner (Steel)Prestige , Gas Pipeisi Brand , German Bub , Glass(6Mm.) , Glass(8Mm.) , Glass Bowl Borosil Big Size , Glass Bowl Borosil Medium Size , Glass Colour Printed 6 Mm , Glass Colour Printed 8 Mm , Glass Door With Accs. , Glass For Drinking Water Borosil , Glass For Drinking Water Ocean , Glass For Torch Light 3 Cell , Glass Frosted 6Mm , Glass Frosted 8Mm , Glass Self For Set-Top Box 12X9 , Glow Sign Board & Accs. Single Side Light , Glow Sign Board & Accs. Single Side Light Glossy , Glow Sign Board With Accs.Double Side Light , Glucon -D , Glucon -D 75 Gm , Godrej Aer Pocket , Good Knight Machine , Good Knight Oil (Refill) , Good-Knight Roll On , Gps Trackerbranded , Graphic Board Branded , Grass Cutting Machine Bladefalcon , Grass Cutting Machine Blade Stihl , Grass Cutting Machine Honda , Green Manual / Cowdung Manual , Grill Iron Rr , Grill Iron Shyam , Grill Iron Tata , Gumboot (All Size) , Gun Oil , Gypsum Board With Fitting , Half Barrel Dustbin (Iron) , Half Pant , Hammer Drill Machine Bosch , Hammer With Handle. (Iron) Bigtata , Hammer With Handle. (Iron) Small Taparia , Hand Bill Printing , Hand Cymbals For Band , Hand Gloves Disposable , Hand Gloves Rubber , Hand Saw 18 , Hand Trolley For Garbage Shifting. 2 Wheeler , Handle For Spade / Gaity/Axe , Handwash Liquid Dettol 200Gm , Handwash Liquid Life-Bouy 200Gm , Hanger Wooden , Hansua Big (Iron)Tata , Hansua Big (Iron) Taparia , Hansua Small (Iron)Taparia , Hansua Small (Iron) Tata , Harpic Blue 500Ml , Harpic Red 500Ml , Harricanetata , Hash Bolt Brasso , Hash Bolt Steel , Head Shower Cap , Heatx Fevicol , Hedge Cutting Scissortata , Hedge Cutting Scissor Taparia , Hedge Shears (For Tree Cutting)(Taparia/Tata) , Hedge Trimmer Machine 420Wt 18 Electric Stihl , Helmet Branded For Mc Rider Steel Bird , Helmet Branded For Mc Riderstudds , Hessian Bag Medium , High Density Foam , High Steamner Head For Brush Cutter Machine.Honda , High Tension Coil For Brush Cutter Machine. Honda , Hindge 1Godrej , Hindge 2 Godrej , Hindge 3 Godrej , Hindge 4Godrej , Hindge 6 Godrej , Hit Spraybalck 400Ml , Hit Spraybalck 625Ml , Hit Spray Red 400Ml , Hit Spray Red 625Ml , Home Guardflag Silk Embodery 3X2 , Home Guardflag Silk Embodery 6X4 , Hooktata , Hook Jindal , Ice Pot , Inauguration Stone With Engraving , Indoor Plant Big (Plastic) , Indoor Plant Small (Plastic) , Insecticide Liquid Branded , Irc Net , Iron Angle Jindal , Iron Angle Tata , Iron Chain ( For Rifle ) Bq , Iron Cot , Iron Door Frame Bq , Iron Door Frame With Palla Bq , Iron File (12)Tata , Iron File (6)Tata , Iron Net Bq , Iron Pack , Iron Pati , Iron Randyaa , Iron Rod (8Mm/10Mm/12Mm/16Mm) Tata , Iron Rod (8Mm/10Mm/12Mm/16Mm)Jindal , Iron Sheet (18 Swg )Jindal , Iron Sheet (18 Swg )Tata , Iron Sheet (20 Swg)Jindal , Iron Sheet (20 Swg)Tata , Iron Stainer , Iron Table , Iron Window Frame With Palla , J. Hooktata , Jerry Can (Pvc)20 Liter Bq , Jerry Cane (Pvc)5 Liter Bq , Jhul Jharu Bq , Jug Copper 2 Ltrmilton , Jug Copper 2 Ltr Cello , Jug Copper 2 Ltr Eagle , Jug Glass Body , Jug Plastic , Jug Steel , Juicer Machine750watt (Bajaj) , Juicer Machine750watt (Kent) , Juicer Machine750watt (Philips) , Jute , Jute Brush , Jute Carpet Normal , Jute Thread , Kamri / Jumbo Tata , Kent Perk (Chiller Cum Water Dispenser ) (Ro+Uf+Tds Controller With Iron Filter & Mineral Ball) Complete Set(Chiller Cum Water Dispenser ) (Ro+Uf+Tds Controller With Iron Filter & Mineral Ball) Complete Set , Kent Ro Membrane , Kerosin Oil , Khurpi Tata , Kitchen Chimneykent , Kitchen Chimney Kuchina , Kitchen Chimneyprestige , Knife Steel 10 With Handel , Knife Steel 8 With Handel , Kopicol Tata , Kopicoltaparia , Kurni Tata , Lawn Mowerblade6 , Lawn Mower Blade 12 , Lawn Mower Blade 9 , Lawn Mower Machine Petrol Hrj 196 Air Cooled 4 Stroke Ohv Single Cylinder 3.2(4.3)@3600/Rpm Honda , Lawn Mower Machine Petrol Rm 248 (Eu1) 2,1 Kw/2,8Ps Stihl , Lid For Glass , Lime Dust , Lime Stone , Link Lock 41 Medium , Lizol 1Ltr , Lizol 500Ml , Logo Printed Boundary Tape (Dont Cross The Line) , Loud Hailer Ahuja , M.S. Pipe 1Tata , M.S. Pipe 1.5Tata , M.S. Pipe 2Tata , Manhole Cover (Iron)Tata , Map( Vinyl Print With Frame) , Marathan Jersey Set , Markin Cloth , Matam , Mattress - 3/6Sleep Well , Mattress - 3/6Dunlopilow , Mattress - 3/6Kurl-On , Mattress - 5/7 Kurl-On , Mattress - 5/7 Dunlopilow , Mattress - 5/7 Sleep Well , Mattress - 7/6Kurl-On , Mattress - 7/6Dunlopilow , Mattress - 7/6Sleep Well , Measurement Stand Steel , Measurement Standwooden , Messonite Board (4 Mm.) , Messonite Board (6 Mm.) , Metal Polish ( 100 Ml) , Metal Primerasianpaints , Metal Primerberger , Mirror Complete Set Johnson , Mirror Cutting Acrylic Led Board , Mirror Cutting Letter , Mirror Glass (6 Mm.) With Frame , Mirror Glass (8 Mm.) With Frame , Mobil Castrol , Mobil Servo , Momo Makerphilips , Momo Makerprestige , Mortain Coil , Mortise Lock Godrej , Mosquito Gun Smoke Machine , Mosquito Netsingle , Mosquito Net Double , Mosquito Trap Electric Bat , Motor Stater For Submersiable Pump , Mug Plastic , Multi Lock , Muriatic Acid 500Ml , Nail , Napthelene Bengal Chemical , National Emblem Brass , National Flag (Paper) (7 X 4) , National Flag Emboudary 3X2 , National Flag Emboudary 6X4 , National Flag Khadi (3 X 2) , National Flag Khadi (6 X 4) , National Flag Silk (3 X 2) , National Flag Silk (6 X 4) , National Flag Velvet (6 X 4) , Navtal Godrej Lock 6 Liver , Navtal Godrej Lock 7 Liver , Navtal Godrej Lock 8 Liver , Net Nylon , Night Vision Goggles , Nimyle 1 Ltr , Nimyle 5 Ltr , Nimyle Herbal Neem 1 Ltr , Nimyle Herbal Neem 5 Ltr , Nose Pliers Taparia , Nut – Bolt 1 , Nut – Bolt 1/2 , Nut – Bolt 2 , Nut Bolt With Washer ½ Jindal , Nut Bolt With Washer ½ Tata , Nut Bolt With Washer 1 Jindal , Nut Bolt With Washer 1 Tata , Nut Bolt With Washer 2 Jindal , Nut Bolt With Washer 2 Tata , Nylon Rope , Nylon Socks , Obstacle Rope , Odomos/ Mosquito Repelant Cream 100Gm , Odonil Air Freshner 48Gm , Odonil Air Freshner 75Gm , Odonil Nature Zipper Air Freshner 10Gm , Odonil Roomfreshning Gelz 75 Gm , Oil Paint 1 Ltr Asianpaint , Oil Paint 100 Ml Asianpaint , Oil Paint 100 Ml Berger , Oil Paint 1Ltr Berger , Oil Paint 4 Ltr. Asianpaint , Oil Paint 4 Ltr. Berger , Oil Seal For Brush Cutter Machine (Per Set) , Ors Liquid 200 Ml Orsl , Ors Orange Sachet Walyte , P.V.C Floor Mat , Paddle Dustbin With Lid Medium - Steel , Paddle Dustbin With Lid Pvc Pvc - Big , Paddle Dustbin With Lid Pvc Pvc - Small , Paint Distemper Asianpaint , Paint Distemper Berger , Paint Snowcem , Paint Synthetic Enamel , Paint Weather Coat Asianpaint , Paint Weather Coat Berger , Painting Brush 0 Size , Painting Brush 1 , Painting Brush 2 , Painting Brush 4 , Painting Brush Round Shape , Paper Dustbin Steel 12 , Paper Dustbin Steel 9 , Paper Tea Cup (60 Ml.) , Paposh ( Cotton) 1.5/3 , Parda Ribbon , Parda Ringplastic , Pastic Tarpauline 24 X 18 , Pastic Tarpauline 4 X 8 , Pastic Tarpauline 40 X 30 , Pastic Tarpauline 40 X 60 , Phenyle Black , Phul Jharu , Phul Jharuspecial , Phytofresh , Picture Frame , Pillow 18Cotton , Pillow Cover 18 , Pillow Cover 18Bombay Dyeing , Pitambari Shining Powder , Pitch Chat (Tarfelt) With Fitting , Plant Pole Stand Brasso 5 , Plant Pole Stand Steel 5 , Plastering With Supply Materials , Plastic Bowl , Plastic Bucket(20 Ltr) Cello , Plastic Bucket(20 Ltr) Nayasa , Plastic Bucket (10 Ltr) Cello , Plastic Bucket (10 Ltr) Nayasa , Plastic Bucket 10Ltr Special , Plastic Bucket 20Ltr Special , Plastic Container Air Tight 1 Ltr. , Plastic Container Air Tight 2 Ltr. , Plastic Flower Tub , Plastic Gumla16 , Plastic Gumla 22 , Plastic Jhuri , Plastic Moulded Chairwithout Arms Nilkamal , Plastic Moulded Chairwithout Arms Cello , Plastic Moulded Chairwithout Arms Supreme , Plastic Moulded Chair With Arms Nilkamal , Plastic Moulded Chair With Arms Cello , Plastic Moulded Chair With Arms Supreme , Plastic Moulded Tea Tablenilkamal , Plastic Moulded Tea Table Supreme , Plastic Plate , Plastic Sheet ( Polythene) , Plastic Table Cloth , Plastic Water Drum(40 Ltr) , Plastic Water Drum(60 Ltr) , Plastic Water Glass (250 Ml.) , Pliers Cutting Taparia , Plug For Brush Cutter Machine , Ply Wood Camp Cot3×7 , Plywood 04 Mm. Water Resistant Century , Plywood 06 Mm. Water Resistantcentury , Plywood 06 Mm. Water Resistant Green Ply , Plywood 09 Mm. Water Resistant Century , Plywood 12 Mm. Water Resistantgreen Ply , Plywood 12 Mm. Water Resistant Century , Plywood 18 Mm. Water Resistant Century , Plywood 24Mm. Water Resistant Century , Podium Fiber Glass , Podium Wooden And Steel , Police Flag Embrodary 1.5X 2.5 , Police Flag Silk Ambroidery 6 X 4 , Police Flag Velvet Ambroidery 6 X 4 , Police Logo With Adhesive , Poly Bag (Cement) , Polythin Bag 10Kg Capacity , Polythin Bag 5Kg Capacity , Primer Woodenberger , Primer Wooden Asianpaints , Probe Metallic , Probe Non-Metallic , Prodder Metallicbig , Prodder Metallic Small , Prodip With Stand Brasso 3Ft Height , Pudding For Wooden Work , Pumper For Cycle , Putty Dulux , Puttyasianpaints , Radyaa (Small) , Raincoatduck-Back , Raincoatk.C Paul , Raincoat Kaliber , Randyaa Machine , Rat Killer Trap , Red Oxide Powder , Red Salu , Regulator For Gas (Lpg) , Rellay Batton , Rifle Oil , Robin Blue , Room Freshner Air-Wick , Room Freshner Godrej , Room Freshner Odonil , Round Casserole Small (Break In Serve) Treo , Round Paint Brush (Roller) , Rsp (Tool Kit) , Rubber Pipefor Generator , Rucksack Aristrocraft , Rucksack Sky-Bags , Rucksack Wildcraft , Sabol 4 Ft Heavy , Safety Goggles , Safety Pin Small , Safty Pin Big , Sand , Sandwitch Toster Bajaj , Sandwitch Toster Prestige , Satin Cloth (Best Quality) , Satranji 9X4 , Saxophone Brasso For Band , School Bag American Tourister , School Bag Ordinery , Scissor ( First Aid Box ) , Scissor (Tailors ) , Screw (1.6) , Screw (1/2) , Screw (2) , Screw (3) , Screw Driver (Big) Taparia , Screw Driver (Small)Taparia , Scrotch Brite , Scrotch Brite Scrub Spong , Self For Set-Top Box 12X9 , Self For Set-Top Box 6X10 , Service Bowlbone Chaina , Service Protector , Shoe Rack Plastic , Shoe Rack Wooden , Side Drum With Stick For Band , Side Pillow , Side Pillow Cover , Sil & Nora , Sliding Door With Fittings , Sliding Glass With Fitting Allm. Channel , Sliding Window With Fittings , Slugging Wrench Taparia , Smart Watch Boat , Smart Watch Fire Boltt , Smart Watch Noise , Smoke Glass (6Mm.) , Smoke Glass (8Mm.) , Snare Drum For Band , Snare Drum Stickfor Band , Soap Case , Soap Dettol , Soap Life-Buoy , Soap Spl Denim , Soap Spl Dove , Soap Spl Lux International , Soap Spl Pears , Socket For Parda , Socket For Parda Wdn , Soda , Sofa Cover , Soil , Spade (Tata) , Spade Handle (Wooden) , Spark Plug For Lawn Mower Machine , Spirit Oil , Spoon Fork Special , Spoon Fork Vip , Spoon Tea Special , Spoon Tea Vip , Stainer 100 Ml , Steam Inhaler Machine , Steel Cot , Steel Letter (Any Size) , Steel Made Q-Manager With Tape , Steel Name Plate , Steel Net With Fitting , Steel Pipe 1 , Steel Pipe 3/4 , Steel Rack 4 Part (H-6, W-4, D-1.5’) , Steel Screw 2 , Steel Tea Container(5Ltr.) Tata , Steel Tea Container (10 Ltr.) Tata , Steel Water Dram 40 Ltr. , Steel Water Dram 60 Ltr. , Stone Chips (1/4”, 1/3”, ½”) , Stove 3 Ltr. , Stove 5Ltr. , Succession Board Correction (Edit) , Succession Board Pvc & Glass , Succession Board Wooden , Suctionpipe 1 , Suctionpipe 1/2 , Suction Pipe 2 , Suction Pipe 3/4 , Sun Board , Sun Pack , Sunmica , Sutali Rope , Swan Shower Net , T-Police Flag Embrodary With Stand , T.C Full Slacks / Camouflaging Cloth , T.C Full Slacks Shirt Camouflaging Cloth , Table Cloth (Terry Cotton) , Table Cover , Table Desk (Acrylic) 2 Long , Table For Iron , Table Glass 10Mm , Table Glass 8Mm , Tarpin Oil , Tawa Iron , Tea Chakni Steel , Tea Container Steel 10 Ltr , Tea Container Steel 5 Ltr , Tea Set , Tea Traybig , Tea Traymalamine , Tea Tray Small , Tempory Toilet Making With Accs , Tharmocol 25 Mm , Thermocol 8Mm , Thinner , Tick Plywood Green Ply , Tiffin Plate Bone Chaina , Tissue Paperbox Standard , Tissue Paperordinary , Tissue Paper Standsteel , Tissue Rollstandard , Toilet Brush , Torch Lightfiber Body ( 3 Cell) Everady , Torch Lightmetal Body ( 3 Cell)Everady , Torch Light Battery , Torch Light Fiber Body ( 5 Cell) Everady , Torch Light Led Metal Body , Torch Light Led Rechargable Everady , Torch Light Led Rechargable Havells , Torch Light Metal Body ( 5 Cell)Everady , Towel(Big) Bombay Dyeing , Towel(Big) Divine Lines , Towel(Big) Rajlaxmi , Towel(Small) Bombay Dyeing , Towel(Small) Divine Lines , Towel(Small) Rajlaxmi , Tower Bolt 12 , Tower Bolt 6 , Transparent Polythin Pouch With Zipper (12X10 ) , Tricycle Van For Garbage Shifting. , Trolley Bag Largeamerican Tourister , Trolley Bag Largesky Bag , Trolley Bag Large Vip , Trolley Bag Mediumamerican Tourister , Trolley Bag Mediumsky Bag , Trolley Bag Medium Vip , Trolley Bag Smallamerican Tourister , Misc. Goods , Trolley Bag Smallsky Bag , Trolley Bag Smallvip , Trolley Wheel , Tubewel , U-Hook (2) , U-Hook (3) , U-Hook (5) , U-Hook (7) , Umbrella Long Handle K.C. Paul , Umbrella Long Handle Orange , Umbrella Long Handle Shark , Uttariya , Valco Male Female , Vanish Liquid 400 Ml , Vanish Liquid 800 Ml , Velvet Cloth , Venile Board , Vernier Caliper(Digital) , Vest White Round Neck Doller , Vest White Round Neck Lux Cozi , Vest White With Collar Doller , Vest White With Collar Lux Cozi , View Cutter Wooden/ Bamboo/Cane Made Per Fold 6X 2 , Vim Dishwash Bar 500Gm , Vim Liquid 250Ml , Vim Liquid 500Ml , Vim Powder 500 Gm , Vinyle Board , Visitors Chair 3 Seated Iron , Visitors Chair 3 Seated Stainless Steel , Wall Clock Ajanta , Wall Clock Digital Ajanta , Wall Clock Orpat , Wall Clock Titan , Wall Colouring By Snocem , Wall Colouring By Washable Distemper , Wall Hanger (For Cloth) , Wall Hanger Steel , Wall Mount For Tv , Wall Tiles With Fitting , Wardrobes , Water Bottle Copper 1 Ltr Eagle , Water Bottle Copper 1 Ltr Milton , Water Bottle Copper 500Ml Eagle , Water Bottle Copper 500Ml Milton , Water Coolerss 20/40 With Kent Filter (Ro+Uf+Tds Controllar)& Iron Filter Complete Set Blue Star , Water Cooler Cum Purifier (Capacity 120 Ltrs) B. Star , Water Diffuser Machine , Water Diffuser Refill , Water Filter 20Ltr , Water Filter As Per Sample , Water Purifier - 50 Ltr Blue Star , Water Purifier - 50 Ltr Eureka Forbs , Water Purifier - 50 Ltr Kent , Water Purifier Aquaguard , Water Purifier Lg , Water Purifier Pure-It , Water Purifier Ro Kent , Wbp Logo Brasso , Wbp Logo Steel , Weight Machine (Digital) Capacity 10 Kg. , Weight Machine (Digital) Capacity 150 Kg , Welding , Welding Machine , Welding Stick , Wheel Detergent Powder 1Kg , Wheel Detergent Powder 500 G , Wheel Soap , White Board , White Board Duster , White Boundary Tape Printing (No Entry) , White Cement Jk , White Full Pant , White Sand , Wind Socks Cloth (Terry Cotton) , Wind Socks Frame (Iron) , Wiper , Wire Brush , Woodgamari , Woodsal , Wood Hard , Wood Neem , Wood Segun/ Tik , Wood Sisu , Wooden Bit , Wooden Bit Gamer , Wooden Bit Koopur , Wooden Chair , Wooden Garanchi , Wooden Gila , Wooden Jinabo Bass Drum , Wooden Laddar , Wooden Mugur 10 Kg , Wooden Mugur 15 Kg , Wooden Pack , Wooden Table Polishing , Wooden Table Top Rexine Repair , Yellow Boundary Tape (No Entry ) , Zeoline 100 Ml , Zeoline 50 Ml , 1 Hp Motor Starter , 16 Amp. Complete Switch Havells , 2 Pin Socket 5 Amp.Anchor , 2 Pin Socket 5 Amp. Havells , 2 Pin Top 16 Amp. Gold Medal , 2 Pin Top 16 Amp. Pritam , 2 Pin Top 6 Amp. Gold Medal , 2 Pin Top 6 Amp. Pritam , 3 Phase Main Cable 35 Mm. Kei , 3 Phase Motor Starter , 3 Phase Motor Switch , 3 Phase Pannel Board , 3 Pin Multi Pluggold Medal , 3 Pin Multi Plug Gold Medal , 3 Pin Multi Plug Presto Plast , 3 Pin Socket 16 Amp. Anchor , 3 Pin Socket 16 Amp.Gold Medal , 3 Pin Socket 6 Amp. Anchor , 3 Pin Socket 6 Amp. Gold Medal , 3 Pin Top 16 Amp.Presto Plast , 3 Pin Top 16 Amp. Gold Medal , 3 Pin Top 6 Amp. Gold Medal , 3 Pin Top 6 Amp. Presto Plast , 4 Core Cable Wire (Alluminium) 25Mm , 4 Core Cable Wire (Alluminium) 35Mm , 4 Core Cable Wire (Alluminium) 50Mm , 5 In 1 Complete Setanchor , 5 In 1 Complete Set Gold Medal , 5 In 1 Complete Set Havells , Ac Plug 16 Amp. With Base , Ac Starter 16 Amp.Anchor , Ac Starter 16 Amp.Gold Medal , Ac Starter 16 Amp.Hevels , Ac Starter 32 Amp.Anchor , Ac Starter 32 Amp.Gold Medal , Ac Starter 32 Amp.Hevels , Alternator A. V. R. For Generator , Aluminium Cable10 Mm. 2 Cores. Rajdhani , Aluminium Cable10 Mm. 2 Cores. Rr , Aluminium Cable16 Mm. 2 Cores. Rajdhani , Aluminium Cable16 Mm. 2 Cores. Rr , Aluminium Cable6 Mm. 2 Cores. , Aluminium Cable8 Mm. 2 Cores. , Aluminium Cable 16 Mm. 4 Cores. , Amplifire 120 Wt.Ahuja , Amplifire 120 Wt. Stranger , Amplifire 2000 Wt. Ahuja , Amplifire 250 Wt. Ahuja , Amplifire 5000 Wt. Ahuja , Amplifire 60 Wt.Stranger , Amplifire 60 Wt. Ahuja , Angle Holderahuja , Angle Holder Gold Medal , Armorer Cable6 Mm. 4 Coreshavells , Armorer Cable 10 Mm. 2 Cores Havells , Armorer Cable 10 Mm. 4 Coreshavells , Armorer Cable 12 Mm. 2 Cores Havells , Armorer Cable 12 Mm. 4 Cores Havells , Armorer Cable 14 Mm. 2 Cores Havells , Armorer Cable 16 Mm. 2 Cores Havells , Armorer Cable 16 Mm. 4 Coreshavells , Armorer Cable 6 Mm. 2 Coreshavells , Armorer Cable 8 Mm. 2 Coreshavells , Armorer Cable 8 Mm. 4 Cores Havells , Battery 12 Volt. For Search Light Everady , Battery 12 Volt. For Search Light Panasonic , Battery 12Volt. Everady , Battery 6 Volt. For Search Light Everady , Battery 9 Volt. For Cordless Mic.Everady , Battery 9 Volt. For Cordless Mic.Panasonic , Battery 9 Volt. For Search Light Everady , Battery For Loud Hailer (R14)Everady , Battery For Stop Watch Everady , Battery For Torchlight , Bearing For Fan6203 Tata , Bearing For Fan 6201 Tata , Bearing For Fan 6202 Tata , Bed Switchanchor , Bed Switch Gold Medal , Bell Push Switch Type5ampgold Medal , Block Tapeanchor , Bluetooth Speaker50 Wattbose , Bluetooth Speaker50 Wattjbl , Bluetooth Speaker 30 Watt Bose , Bluetooth Speaker 30 Watt Jbl , Bold Jack , Bulb 100 Wt.Philips , Bulb 200 Wt. Philips , Bulb 60 Wt. Philips , Bulb For Torch Light , Bulb Holder Anchor , Bulb Holder Gold Medal , Busbar Junction Box 100 Amp. Havells , Busbar Junction Box 150 Amp. Havells , Busbar Junction Box 32 Amp.Havells , Busbar Junction Box 63 Amp.Havells , Cable Connector Chinamati , Calling Bell Battery 23A-12V , Calling Bell Wire Less - Electriccona Smyle , Calling Bell Wire Less - Electric Anchor , Capacitor For Fan (2.5/3.15 Mfd.) Tibcon , Capacitor For Fan (2.5/3.15 Mfd.) Havells , Capacitor For Water Pump , Caseing1 ½ Presto Plast , Caseing1Presto Plast , Caseing1 Preety , Caseing ¾ Presto Plast , Casing Board (4/4) (Presto Plast) , Casing Board (7/4) (Presto Plast) , Casing Board (7/5) (Presto Plast) , Casing Board (8/10) (Presto Plast) , Casing Board (8/10) Preety , Casing Board (8/6) (Presto Plast) , Casing Board (8/6) Preety , Cassing Corner 4 Way T 1Presto Plast , Cassing Corner 4Way T 3/4 Presto Plast , Cassing Corner Elbow 1Presto Plast , Cassing Corner Elbow 3/4 Presto Plast , Cassing Corner External 1 Presto Plast , Cassing Corner External 3/4 Presto Plast , Cassing Corner Internal 1Presto Plast , Cassing Corner Internal 3/4 Presto Plast , Cassing Corner T 1Presto Plast , Cassing Corner T 3/4 Presto Plast , Ceiling Fan 48Havells , Ceiling Fan 48Poly Cab , Ceiling Fan 52Havells , Ceiling Fan 52Poly Cab , Ceiling Fan Clumb Rod S Type , Ceiling Rosehavells , Ceiling Rose Anchor , Ceiling Rose Presto Plast , Celling Pannel Light Led 10×10 Inch. Hansagreen , Celling Pannel Light Led 10×10 Inch. Havells , Celling Pannel Light Led 12×12 Inch. Hansagreen , Celling Pannel Light Led 12×12 Inch. Havells , Celling Pannel Light Led 4×4 Inch. Hansagreen , Celling Pannel Light Led 4×4 Inch. Havells , Celling Pannel Light Led 6×6 Inch. Hansagreen , Celling Pannel Light Led 6×6 Inch. Havells , Celling Pannel Light Led 9×9 Inch. Hansagreen , Celling Pannel Light Led 9×9 Inch. Havells , Changer Ac/Dc 100 Amp. Flora , Changer Ac/Dc 16 Amp.Flora , Changer Ac/Dc 16 Amp.Havells , Changer Ac/Dc 32 Amp. Flora , Changer Ac/Dc 32 Amp. Havells , Changer Ac/Dc 60 Amp. Flora , Changer Ac/Dc 60 Amp. Havells , Charger Cord Type - B , Charger Cord Type - C , Charger Cord Type -Usb , Chinamati Holder , Choke For Tube-Light (Electronic)Philips , Chong (Mike Set) Aluminum , Circular Pvc 1 Wayhavells , Circular Pvc 2 Way Havells , Circular Pvc 3 Way Havells , Circular Pvc 4 Wayhavells , Combined Board ( 5 In 1) , Condenser Clamp , Condenser For Motor Havells , Connecting Kathi Cord , Copper Cable (3 Phase) 16Mm Kei , Copper Cable (3 Phase) 25Mmkei , Copper Wire 16Mmfinolex , Copper Wire 16Mm Rr , Copper Wire 25Mm Finolex , Copper Wire 25Mm Rr , Cordless Microphone Ahuja , Cordless Microphone Jbl , Cordless Microphone Sony , Cutout 100 Amp. Flora , Cutout 100 Amp. Gold Medal , Cutout 150 Amp. Flora , Cutout 150 Amp. Gold Medal , Cutout 16 Amp. Flora , Cutout 16 Amp. Gold Medal , Cutout 200 Amp. Flora , Cutout 200 Amp.Gold Medal , Cutout 32 Amp.Flora , Cutout 32 Amp. Gold Medal , Cutout 63 Amp.Gold Medal , Cutout 63 Amp. Flora , Decorative Ceilling Light , Decorative Wall Light , Dish/Cable Wire , Double Bracket Light Havells , Double Complete Tube Light Set.Havells , Drill Bit 10 Mm.Makati , Drill Bit 12 Mm.Makati , Drill Bit 14 Mm.Makati , Drill Bit 16 Mm.Makati , Drill Bit 6 Mm.Makati , Drill Bit 8 Mm.Makati , Drill Bit Bosch , Drill Machine With Tools 700 Wt. Bosch , Earthing Building To Stand Rod , Earthing Connector , Earthing Copper Plate , Earthing Copper Wire , Earthing Rod , Electric Cord , Electric Cutter Machine Bosch , Electric Drill Machinebosch , Electric Ironbajaj , Electric Ironhavells , Electric Kettlebajaj , Electric Kettlehavells , Electric Kettleprestige , Electric Switch Board , Electric Wire Connecter/Jointer , Emergency Charger Lighteverady , Emergency Charger Light Sigma , Emergency Light Battery 6 Volt.Sigma , Engaged Electric Board , Equalizer Machine Dn360 Soundcraft , Exhaust Fan 12Luminous , Exhaust Fan 12 Bajaj , Exhaust Fan 12 Crompton , Exhaust Fan 22Crompton , Exhaust Fan 22 Bajaj , Exhaust Fan 22 Luminous , Exhaust Fan 9Luminous , Exhaust Fan 9 Bajaj , Exhaust Fan 9 Crompton , Extension Board , Extension Cord Board 10Amp Havells , Extension Cord Board 10Amp Gold Medal , Extension Cord Board 16Amp Havells , Extension Cord Board 16Amp Gold Medal , Flat Pin Shuttle , Flexible Pipe (1/2) , Flexible Pipe (3/4) , Flexible Wire 3/20 , Flexible Wire 3/22 , Flexible Wire 7/20 , Flexible Wire 7/22 , Fuse 16 Amp.Havells , Fuse 32 Amp.Havells , Fuse 63 Amp. Flora , Geyser 10 Ltr.Bajaj , Geyser 10 Ltr. Havells , Geyser 15 Ltr.Havells , Geyser 15 Ltr. Bajaj , Geyser 7 Ltr. Bajaj , Geyser 7 Ltr. Havells , Gi Satel ¾ , Gi Satel 1 , Gi Satel 1/2 , Gi Wire , Globe Holder , Globe Holder Stand , Globe Light 10 Havells , Globe Light 12Anchor , Globe Light 16Havells , Grinder Machine Bosch , Hair Dryerhavells , Hair Dryerphilips , Indicator 5 Amp. Anchor , Induction Ovenbajaj , Induction Ovenhavells , Induction Ovenprestige , Iron Box 3 X 3 , Iron Box 4 X 10 , Iron Box 4 X 12 , Iron Box 4 X 14 , Iron Box 4 X 4 , Iron Box 4 X 6 , Iron Box 4 X 8 , Isolater 100 Ampflora , Isolater 100 Amp Havells , Isolator 40Amphavells , Isolator 40Amp Flora , Jbl Sound Box 1000 Wt. , Jbl Sound Box 200 Wt. , Jbl Sound Box 400 Wt. , Jbl Sound Box 600 Wt. , Jharbati With Led Lamp Special , Joint Box 3/3 Pvcpreeti Plast , Kitchen Chimneyv-Guard , Kitchen Chimney Kutchina , L Hook (Iron) , Led Bulb 14 Wt.Philips , Led Bulb 14 Wt. Havells , Led Bulb 20 Wt.Havells , Led Bulb 20 Wt. Philips , Led Bulb 24 Wt.Havells , Led Bulb 24 Wt. Philips , Led Bulb 5 Wt Philips , Led Bulb 9 Wt.Philips , Led Bulb 9 Wt. Havells , Led Flood Light300watt Philips , Led Flood Light400watt Philips , Led Flood Light500watt Philips , Led Flood Light50watt Philips , Led Flood Light 100Watt Philips , Led Flood Light 15Watt Philips , Led Flood Light 200Watt Philips , Led Flood Light 30Watt Philips , Led Metal Light 100 Wt.Havells , Led Metal Light 100 Wt.Philips , Led Metal Light 200 Wt.Philips , Led Metal Light 50 Wt.Philips , Led Night Bulb Khaitan , Led Night Bulb Philips , Led Open Surface Globe Light 10 Havells , Led Open Surface Globe Light 10 Anchor , Led Open Surface Globe Light 12 Havells , Led Open Surface Globe Light 12 Anchor , Led Open Surface Globe Light 16 Havells , Led Open Surface Globe Light 16 Anchor , Led Open Surface Globe Light 18 Havells , Led Rice Chain , Led Street Light 100Watt Philips , Led Street Light 200Watt Philips , Led Street Light 25Watt Philips , Led Street Light 30Watt Philips , Led Street Light 45Watt Philips , Led Street Light 60Watt Philips , Led Strip Light , Led Table Lamp , Led Television (28)Lg , Led Television (28)Samsung , Led Television (28)Sony , Led Television (32)Lg , Led Television (32)Samsung , Led Television (32)Sony , Led Television (48)Lg , Led Television (48)Sony , Led Television (48) Samsung , Led Tubelight 20 Wt , Led Tubelight 24 Wt , Led Tubelight 36 Wt , Light Fittings (Bracket) , Main Switch 100 Amp.Flora , Main Switch 100 Amp. Havells , Main Switch 16 Amp. Flora , Main Switch 16 Amp. Havells , Main Switch 32 Amp. Flora , Main Switch 32 Amp. Havells , Main Switch 63 Amp. Flora , Main Switch 63 Amp. Havells , Male & Female Jackgold Medal , Male & Female Jack Anchor , Mcb 10Amp. (Single Pole)Anchor , Mcb 10Amp. (Single Pole) Gold Medal , Mcb 16 Amp. (Double Pole) Gold Medal , Mcb 16 Amp. (Double Pole) Anchor , Mcb 16 Amp. (Single Pole)Anchor , Mcb 16 Amp. (Single Pole)Gold Medal , Mcb 20 Amp. (Double Poll) , Mcb 32 Amp. (Double Pole) Anchor , Mcb 32 Amp. (Double Pole) Gold Medal , Mcb 32 Amp. (Single Pole)Anchor , Mcb 32 Amp. (Single Pole)Gold Medal , Mcb 40 Amp. (Single Pole) , Mcb 6 Amp. (Single Pole)Gold Medal , Mcb 6 Amp. (Single Pole) Anchor , Mcb 63 Amp. (3 Poll)Gold Medal , Mcb 63 Amp. (Double Pole) Gold Medal , Mcb Boxgold Medal , Mcb Pannel Box 10 Modulegold Medal , Mcb Pannel Box 12 Modulegold Medal , Mcb Pannel Box 14 Modulegold Medal , Mcb Pannel Box 8 Modulegold Medal , Microphone Ahuja , Microphone Cord , Microphone Gear , Microphone Jack , Microphone Jack (Input) , Microphone Jack (Output) , Microphone Stand Big , Microphone Stand Small , Microwave Oven 21 Ltrslg , Microwave Oven 21 Ltrs Ifb , Microwave Oven 21 Ltrs Samsung , Microwave Oven 32 Ltrslg , Microwave Oven 32 Ltrs Ifb , Microwave Oven 32 Ltrs Samsung , Microwave Oven Glass Bowl With Lid 1 Ltr Borosil , Microwave Oven Glass Bowl With Lid 2 Ltr Borosil , Microwave Oven Glass Bowl Without Lid 1 Ltr Borosil , Microwave Oven Glass Bowl Without Lid 2 Ltr Borosil , Mike Unit 100 Watt Ahuja , Mike Unit 60 Wattahuja , Mixture Grinder Machine 1000 Wt. Bajaj , Mixture Grinder Machine 1000 Wt. Havells , Mixture Grinder Machine 1000 Wt. Philips , Mixture Machine 08 Channel , Mixture Machine 12 Channel , Mixture Machine 24 Channel , Mixture Machine 32 Channel , Modular 1Way Switchgold Medal , Modular 2Way Switchgold Medal , Modular Bed Push Switchgold Medal , Modular Blanker For Switch , Modular Board (Surface) 1 Modulegold Medal , Modular Board (Surface) 10 Modulegold Medal , Modular Board (Surface) 10 Modulemaru , Modular Board (Surface) 12 Modulegold Medal , Modular Board (Surface) 12 Modulemaru , Modular Board (Surface) 14 Modulegold Medal , Modular Board (Surface) 16 Modulegold Medal , Modular Board (Surface) 2 Modulegold Medal , Modular Board (Surface) 3 Modulegold Medal , Modular Board (Surface) 4 Modulegold Medal , Modular Board (Surface) 4 Modulemaru , Modular Board (Surface) 6 Modulegold Medal , Modular Board (Surface) 8 Modulegold Medal , Modular Board (Surface) 8 Modulemaru , Modular Board Cover Blank Sheet 4/4 Gold Medal , Modular Board Cover Blank Sheet 5/5 Gold Medal , Modular Board Cover Blank Sheet 5/7 Gold Medal , Modular Board Cover Blank Sheet 5/8 Gold Medal , Modular Board Cover Blank Sheet 5/9 Gold Medal , Modular Dish/Cable Socket , Modular Indicator Gold Medal , Modular Mcb 10 Amp. Gold Medal , Modular Mcb 100 Amp Gold Medal , Modular Mcb 16 Amp. Gold Medal , Modular Mcb 32 Amp. Gold Medal , Modular Mcb 6 Amp. Gold Medal , Modular Mcb 63 Amp.Gold Medal , Modular Regulator Tuner Type Gold Medal , Modular Socket 2 Pin 6 Ampgold Medal , Modular Socket 5 Pin 16 Amp Gold Medal , Modular Socket 5 Pin 6 Amp Gold Medal , Modular Switch 16 Amp. Gold Medal , Modular Switch 16 Amp. Havells , Modular Switch 6 Amp. Gold Medal , Modular Switch 6 Amp. Havells , Modular Telephone Socket Gold Medal , Modular Top4 Modular Gold Medal , Modular Top6 Modularvivan , Modular Top6 Modular Gold Medal , Modular Top8 Modular Gold Medal , Modular Top8 Modular Vivan , Modular Top9 Modularvivan , Modular Top9 Modular Gold Medal , Modular Top 12 Modular Gold Medal , Modular Top 12 Modular Vivan , Modular Top 4 Modular Vivan , Monitor Sound Box 250 Wt , Multi Socket 10 Amp. Vivan , Multi Socket 6 Amp.Vivan , New Electric Wiring By Casing With All Accs. , Off On Switch (Charger) , Pencil Battery Aaduracell , Pencil Battery Aaeveready , Pencil Battery Aapanasonic , Pencil Battery Aaaduracell , Pencil Battery Aaaeveready , Pencil Battery Aaapanasonic , Pendulum Holder , Plug 3 Pinhavells , Plug 5 Pinhavells , Plustaparia , Professional Conference Microphone , Pvc Borfipresto Plast , Pvc Conceal Pipe Forelectrical Wiring ¾ , Pvc Conceal Pipe For Electrical Wiring 1 , Pvc Gutkha , Pygmybulbanchor , Pygmybulbphilips , Rccb 100 Amp. Gold Medal , Rccb 16 Amp. Gold Medal , Rccb 32 Amp. Gold Medal , Rccb 64 Amp. Gold Medal , Regulator Electronicbranded , Room Heater 2000 Watt Bajaj , Room Heater 2000 Watt Havells , Room Heater 2000 Watt Usha , Room Heater Coil , Rooti Maker , Satel 1 Pvc , Satel 10 Mm. Pvc , Satel 12 Mm. Pvc , Satel 14 Mm. Pvc , Satel 16 Mm. Pvc , Satel 18 Mm. Pvc , Satel 4 Mm. Pvc , Satel 6 Mm. Pvc , Satel 8 Mm. Pvc , Search Lightdomoda Dm-2665 , Search Lightdomoda Dm-2671 , Search Lightdomoda Dm-2678 , Search Light Detec 800 Mtr Night Visual , Search Light Fos For Army 55Wt , Single Bracket Lighthavells , Single Bracket Lightphilips , Single Phase Motor Switch 25 Ampanchor , Single Phase Motor Switch 25 Amp Philips , Smart Led Bulbhavells , Smart Led Bulb Philips , Sodium Vapor Bulb 250Watt , Sodium Vapor Choke 250Watt , Sodium Vapor Complete Set250watt , Sodium Vapor Condenser250watt , Sodium Vapor Ignator250watt , Soldering Iron (Solderon) , Soldering Kit , Spot Light Conceal 12 Wt.Havells , Spot Light Conceal 6 Wt.Havells , Spot Lightconceal 14 Wt.Havells , Spot Lightconceal 20 Wt.Havells , Spot Lightconceal 3 Wt.Havells , Spot Lightconceal 9 Wt.Havells , Spring Pipe 1/2 Electric Wiring Use , Spring Pipe 3/4 Electric Wiring Use , Stabailizer 10 Kb Auto For Dj V-Guard , Stabailizer 15 Kb Auto For Dj V-Guard , Stabailizer 5 Kb Autov-Guard , Stabailizer 5 Kb Auto Havells , Stand Fan 18Bajaj , Stand Fan 18 Havells , Stand Fan 22Bajaj , Stand Fan 22 Havells , Stand Fan 24Bajaj , Stand Fan 24Havells , Starter For Ac Machine/ North West(Anchor) 16 Amp. , Starter For Ac Machine/ North West(Anchor) 32 Amp. , Stopwatch , Straight Pipe 1/2 , Straight Pipe 2 Way Circular , Straight Pipe 3 Way Circular , Straight Pipe 3/4 , Straight Pipe 4 Way Circular , Straight Pipe Clump , Straight Pipe Elbow , Straight Pipe Socket , Straight Pipe T , Street Light Complete Set. Led Philips , Sub Marshall Pump 2 Hp.Crompton , Sub Marshall Pump 2 Hp.Kirloskar , Sub Marshall Pump 3 Hp. Crompton , Sub Marshall Pump 3 Hp. Kirloskar , Switch 15 Amp.Anchor , Switch 5 Amp.Anchor , Switch Board 10 X 12 (Pvc) With Cover(Presto Plast) , Switch Board 3 X 3 (Pvc) With Cover(Presto Plast) , Switch Board 4 X 10 (Pvc) With Cover(Presto Plast) , Switch Board 4 X 12 (Pvc) With Cover(Presto Plast) , Switch Board 4 X 4 (Pvc) With Cover(Presto Plast) , Switch Board 4 X 6 (Pvc) With Cover(Presto Plast) , Switch Board 6 X 10 (Pvc) With Cover (Presto Plast) , Switch Board 8 X 12 (Pvc) With Cover(Presto Plast) , Switch Board Wooden 8×12 , Table Fan (Fiber) Bajaj Bajaj , Table Fan (Fiber) Crompton Crompton , Table Fan (Fiber) Havells Havells , Telephone Receiverajanta , Telephone Receiver Orpat , Telephone Receiver Wire Bq , Telephone Wire Bq , Testertaparia , Top 15 Amp.Anchor , Top 5 Amp. Anchor , Torchlightled Flashlight 3 Mode Long Range , Torchlight Damoda Exploring Dm-8895 , Transformer12vt , Transformer 2 Amp, 12Vt(Charger) , Tulu Pump 1 Hp. Crompton , Tulu Pump 1 Hp. Kirloskar , Tulu Pump 1/2 Hp.Crompton , Tulu Pump 1/2 Hp.Kirloskar , Tulu Pump 2Hp.Kirloskar , Tumbler Switch 16Amp , Vacuum Cleaner Eureka Forbs , Vacuum Cleaner Philips , Vocal Maicrophone , Vocal Maicrophone Cordless , Wall Bracket Lamp Double , Wall Fancrompton , Wall Fanhavells , Wall Mounting Fan 12Havells , Wall Mounting Fan 12Luminous , Wall Mounting Fan 18Luminous , Wall Mounting Fan 18 Havells , Wall Mounting Fan 20Havells , Wall Mounting Fan 20Luminous , Wall Mounting Fan 6Luminous , Wall Mounting Fan 6 Havells , Washing Machine Lg , Washing Machine Ifb , Water Heater1000 Watt Bajaj , Water Heater1000 Watt Philips , Water Heater1200watt Bajaj , Water Heater500 Wattbajaj , Water Heater500 Watt Philips , Water Level Scale , Wire10 Mm.Copper Havells , Wire10 Mm.Copper Polycab , Wire10 Mm.Copper Rr , Wire 0.75 Mm. Copper Havells , Wire 0.75 Mm. Copper Polycab , Wire 0.75 Mm. Copper Rr , Wire 1.00 Mm.Copper Polycab , Wire 1.00 Mm. Copper Havells , Wire 1.00 Mm.Copper Rr , Wire 1.5 Mm. Copper Havells , Wire 1.5 Mm. Copper Polycab , Wire 1.5 Mm. Copper Rr , Wire 2.5 Mm. Copper Havells , Wire 2.5 Mm.Copper Polycab , Wire 2.5 Mm.Copper Rr , Wire 4 Mm. Copper Havells , Wire 4 Mm. Copper Polycab , Wire 4 Mm. Copper Rr , Wire 6 Mm. Copper Havells , Wire 6 Mm. Copper Polycab , Wire 6 Mm. Copper Rr , Wire 8 Mm.Copper Havells , Wire 8 Mm.Copper Polycab , Wire 8 Mm.Copper Rr , Wire Copperflexiable14/40 , Wire Cuttertaparia , Wire For Microphone , Wire Stripping Plier , Wooden Gutkha , 0.5 Hp Mono Block Pump Kirloskar , ½ Elbow (Pvc) Supreme , ½ M.T.A (Upvc)Supreme , ½Union (Gi)Hb , ½ ×2 Extension Nipple Tata , ½ ×3 Extension Nipple Tata , ½ 4 Way Tee (Metal)Hb , ½ Angularstop Cockjackware , ½ Angularstop Cock Hindware , ½ Ball Valve (Pvc)Supreme , ½ Bib Cock (Brass)Hindware , ½ Bib Cock (Iron) D-Sons , ½ Bib Cock (Iron)Jackware , ½ Bib Cock (Pvc)Supreme , ½ Brash Net , ½ C.I. Bib Cock Tata , ½ Elbow (Cpvc)Supreme , ½ Elbow (Metal)Tata , ½ Elbow (Upvc) Supreme , ½ F. Tee (Upvc) Supreme , ½ F.T.Asupreme , ½ F.T.A (Metal)Hb , ½ Hand Shower Hindware , ½ Hand Showerjackware , ½ Hand Shower Pvc , ½ Hook (Gi) , ½ Inner Parts (Bibcock) , ½ Jet Shower Hindware , ½ Jet Shower Jackware , ½ Long Body Bib Cock Steel Hindware , ½ Long Body Bib Cock Steel Jackware , ½ M.T.A (Cpvc)Supreme , ½ M.T.A (Metal) Tata , ½ Pipe Cpvcsupreme , ½ Pipe Gitata , ½ Pipe Pvcsupreme , ½ Pipe Upvc Supreme , ½ Plug G.I Tata , ½ Socket (Metal)Hb , ½ Stop Cock Sp + Ci Hb , ½ Tank Ball Valve , ½ Tee (Cpvc) Supreme , ½ Tee (Gi) Tata , ½ Tee (Metal) Tata , ½ Tee (Pvc) Supreme , ½ Tee (Upvc) Supreme , ½ Union (Upvc) Supreme , ½ Union Pvc Supreme , ½ Water Tape D-Sons , ½ X 1 T- Socket (Pvc) Supreme , ½ X 12 Nipple (Gi)Tata , ½ X 18 Connectorpvc Supreme , ½ X 18 Nipple (Gi)Tata , ½ X 2 Balve Angate (Upvc) Supreme , ½ X 2 Nipple (Gi)Tata , ½ X 24 Connectorpvc Supreme , ½ X 3 Nipple (Gi)Tata , ½ X 36 Nipple (Gi)Tata , ½ X 4 Nipple (Gi)Tata , ½ X 6 Long Screw , ½ X 6 Nipple (Gi)Tata , ½ X36 Connectorpvc X Supreme , ½×1½ Extension Nipple Tata , ¾ Ball Valve Pvc Supreme , ¾ Cp Conceal Stop Cock Essco , ¾ Cp Conceal Stop Cock(Jackware/Hindware) , ¾ Elbow (Cpvc) Supreme , ¾ Elbow (Metal) Tata , ¾ Elbow (Upvc) Supreme , ¾ Elbow Upvc Supreme , ¾ F. T. A (Pvc)Supreme , ¾ F. Tee (Upvc)Supreme , ¾ F.T.A (Metal)Supreme , ¾ Gate Valve (Pvc) Supreme , ¾ Hook (Gi) , ¾ M.T.A (Metal)Supreme , ¾ M.T.A (Pvc) Supreme , ¾ Non Return Valve Supreme , ¾ Pipe (Cpvc) Supreme , ¾ Pipe (Gi)Tata , ¾ Pipe (Pvc)Supreme , ¾ Pipe Pvcsupreme , ¾ Plugtata , ¾ Socket (Metal) Tata , ¾ Socket (Upvc) Supreme , ¾ Stop Cock Sp + Ciessco , ¾ Stop Cock Sp + Ci Jackware , ¾ T Socket Pvc Supreme , ¾ Tee (Cpvc)Supreme , ¾ Tee (Metal)Supreme , ¾ Tee (Upvc) Supreme , ¾ Tee Upvc Supreme , ¾ Union (Cpvc) Supreme , ¾ Union (Upvc) Supreme , ¾ White Pipe (Upvc) Supreme , ¾ X ½ Elbow (Metal)Supreme , ¾ X ½ Elbow (Pvc) Supreme , ¾ X ½ One Side Brash Elbow And T (Upvc) Supreme , ¾ X ½ T Socket Pvc Supreme , ¾ X 1Bush (Upvc)Supreme , ¾ X 18 Nipple (Gi)Tata , ¾ X 6 Long Screw With Washer , ¾X ½Elbow Pvc Supreme , ¾X ½ Tee (Metal)Supreme , ¾X 12 Nipple (Gi)Tata , ¾X 6 Nipple (Gi)Tata , 1 Hp Packer Jet Pumpcrompton Greaves , 1 Hp Submarshable Pump Crompton Greaves , 1 Hp Submarshable Pumpkirloskar , 1 X ¾T Socket Supreme , 1 Ball Valve Supreme , 1 Cap (Pvc)Supreme , 1 Check Valve (Brass)Gagan , 1 Elbow (Cpvc)Supreme , 1 Elbow (Metal)Gagan , 1 Elbow (Pvc)Supreme , 1 Gate Valvesupreme , 1 Hook , 1 M.T.A (Pvc) Supreme , 1 Ms Plug Gi Supreme , 1 Pipe (Cpvc) Supreme , 1 Pipe Clump , 1 Pipe Cutter Dia , 1 Pipe Gitata , 1 Pipe Pvcsupreme , 1 T Socket (Pvc) Supreme , 1 Tank Ball Valve , 1 Tee (Pvc) Supreme , 1 Union (Pvc) Supreme , 1 Union (Upvc) Supreme , 1 X ½ Elbow (Metal)Hb , 1 X ½ Elbow Supreme , 1 X ½ T Pvc Supreme , 1 X ½ T Socket Hb , 1 X ½ Tee (Metal)Hb , 1 X ¾ Elbow Pvc Supreme , 1 X ¾ T Supreme , 1 X 6 Long Screw With Washer , 1X ½ Elbow Pvc Supreme , 1X 3 Nipple (Gi) Tata , 1X 4 Nipple (Gi) Tata , 1X12 Nipple (Gi) Tata , 1/2×4 Extension Nipple Tata , 1¼Clamp Pipe , 1¼Pipe Gi Tata , 1¼ Clamp (Gi) Tata , 1¼ Clamp (Pvc) Supreme , 1¼ Cp Basin Waistbaishali , 1¼ Elbow (Cpvc)Supreme , 1¼ F. Tee (Upvc)Supreme , 1¼ Metro Flash , 1¼ Pipe (Cpvc)Supreme , 1¼ Pipe (Pvc)Supreme , 1¼ Push Bend Pvc Supreme , 1¼ Push Pipe Pvc Supreme , 1¼ Push T (Pvc)Supreme , 1¼ Tee (Cpvc)Supreme , 1¼ Union (Upvc)Supreme , 1¼ X 1½ Clamp Screw (Pvc)Supreme , 1½ Ball Valve Pvc Supreme , 1½ Elbow (Cpvc) Supreme , 1½ F. Tee (Upvc)Supreme , 1½ Ori-Plustpipe 80 Mm (Pvc)Supreme , 1½ Pipe (Cpvc)Supreme , 1½ Pipe (Pvc)Finolex , 1½ Pipe (Pvc)Supreme , 1½ Pipe Cutter Diataparia , 1½ Pipe Gitata , 1½ Plug Cutter Taparia , 1½ Sockettata , 1½ Tee (Cpvc)Supreme , 1½ Tee (Metal)Hb , 1½Check Valve (Brass)Gagan , 14 -15 Dalwrenchtaparia , 16X 20 Basinhindware , 18Pipe Wrench Taparia , 2 Hp Submarshable Pumpcrompton Greaves , 2 In 1 Angular Stop Cockhindware , 2 In 1 Angular Stop Cockjackware , 2 In1 Bibcock (Cp)Essco , Misc. Goods , 2 In1 Bibcock (Cp)Jackware , 2 Pipe (Pvc)Finolex , 2 Pipe (Pvc)Supreme , 2 Pipe Gitata , 26-27 Box Ranch Taparia , 3 Hp Submarshable Pumpcrompton Greaves , 3 In 1 Wall Mixcher Jaguar , 3 C.M. Pipe Ori-Plust , 3 Clamp (Gi) , 3 Clamp (Pvc)Supreme , 3 Cowleysupreme , 3 Door Bendsupreme , 3 Door Tsupreme , 3 Pipegi Tata , 3 Pipe Pvc Supreme , 3 Plain Band Pvc Supreme , 3 Plain T Pvc Supreme , 3 Tee Pvc Supreme , 3 X 1½ ® Socket Pvc Supreme , 3 X 12 Nipple (Gi)Tata , 3/8 X 3 Full Thread Nut Bolt With Washer , 4 Clamp (Pvc)Supreme , 4 Cowleysupreme , 4 Door Bendsupreme , 4 Door Elbow (Pvc) Supreme , 4 Door Tsupreme , 4 Pipe Gitata , 4 Pipe Pvc Supreme , 4 Shu Bandsupreme , 4 Tee Pvc Supreme , 6 Pipe Gitata , 8 Pipe Gitata , Anglo Indian Commode Cistern Cera , Anglo Indian Commode Cistern Hindustan , Anglo Indian Commode Cistern Hindware , Anglow India Commode Set Cera , Anglow India Commode Set Hindustan , Anglow India Commode Set Hindware , Ball Cock(Plastic) ½ Supreme , Ball Cock(Plastic)¾ Supreme , Ball Cock (Brass ½ Gagan , Ball Cock (Brass ¾Gagan , Ball Cock (Brass) 1Gagan , Ball Cock (Plastic) 1Supreme , Ball Valve Brass1gagan , Ball Valve Brass ½ Gagan , Basin (16 X 20)Cera , Basin (16 X 20)Hindware , Basin Nut-Bolt Set , Basin Waste Cap , Basin Waste Pipe , Bath Tub West And Cap Luxury , Bati Cap½ , Bati Cap1 , Bati Cap1½ , Bibcock Spandle Counter Turnessco , Bibcock Spandle Counter Turnjackware , Bon Fit Liquid 100 Gm. Bon Fit , Bucket, Seat Valve12 , Bucket, Seat Valve6 , C.P Bati Upvc Supreme , C.P Capcpvc Supreme , C.P Head Shower ½ Essco , C.P Head Shower ½Jackware , C.P Nut , C.P Socket , C.P. Bib Cock ½ Jackware , C.P. Bib Cock ½ Parryware , C.P. Pillar Cock ½ Jackware , C.P. Pillar Cock ½ Parryware , Cheack Valvegagan , Chheni Iron Tata , Chisel Taparia , Commodecera , Commodehindware , Commode Nut-Bolt Set , Commode Sit Coverhindware , Commode Sit Covercera , Conceal Stop Cock Spandle , Connector Pipe18 Supreme , Connector Pipe24 Supreme , Cp Angular D-Sons , Cupling 1 Ruby , Cupling. ½ Ruby , Cupling. ¾Ruby , Cupling. 1½ Ruby , Deep Tubuwel Tata , First Nut , Flash Vulve Hindware , G.I Pipe½ Tata , G.I Pipe¾ Tata , G.I Pipe1½ Tata , Garden Pipe¾ Darshan , Garden Pipe1Darshan , Gi Pipe1 Tata , Gi Pipe 1.25 Tata , M Seal (Plumber ) 100G , M Seal (Plumber ) 50G , No -2,3,4 Cutter Turn Spandel Taparia , No-2,3,4 Spandeltaparia , Ori-Plust Jaknet Filter Ori-Plust , O-T Big Pan Hindware , O-T Small Pan Hindware , P- Type Connecthindware , P- Type Sypanhindware , Pillar Cock Cp D-Sons , Pipe Wrench Single Sidedadjustable 12 (Taparia) , Pipe Wrench Single Sidedadjustable 14 (Taparia) , Pipe Wrench Single Sidedadjustable 18 (Taparia) , Piston Rod , Planjer , Pvc Cistern , Pvc Pipe Cutter Machine , Reduation Socke ¾ , Reduation Socke 1½ , Reduation Socket 1 , Reducer Socket 4×3 (Pvc) , S- Type Sypun , Sheldon Cement 600 Gm , Sink Steel 12×16 Tata , Sink Steel 16X20 Tata , Sink Steel 18X20 Tata , Siphon , Sistern Balcock Washer , Sistern Ball Cock , Sistern Sailnone , Soap Tray , Solvond Liquid Gum (Cpvc) , Solvond Liquid Gum (Upvc) , Spandle Washer , S-Type Connect , Tissue Holderfor Bathroom , Towel Ring Bq , Towel Rod 2 , Towel Rod 3 , Towel Rod 4 , Tube Well Base Tata , Tube Well Body. , Tube Well Filter ( Iron) , Tube Well Filter Pvc Bq , Tube Well Handle Tata , Tube Well Head Tata , Tube Well Sinking Charges , Tube Well Washer Pvc , Urinal Pan Jents(Cera) , Urinal Pan Jents(Hindustan) , Urinal Pan Jents (Hindware) , Urinal Pan Ladies (Cera) , Urinal Pan Ladies (Hindustan) , Urinal Pan Ladies (Hindware) , Urine Cap , Viasni Trap And Cover (Pvc) , Wall Mounted Comod Set , Waste Cap1 , Waste Cap 1½ , Waste Phanel , Waste Pipe 1 , Waste Pipe 1½ , Water Tank 3 Layersunplast , Water Tank 3 Layersupreme , Water Tank 4 Layerpoly P4 , Water Tank 4 Layersupreme , Water Tank 5 Layersunplast , Water Tank 5 Layersupreme , Aiming Rest , Allen Key Taparia , Aluminium Seal , Armoury Tools Rack , Baynot Frog (Mark-Iii) , Bindulium , Chindi , Cleaning Rod For Insas , Cleaning Rod For Revolver , Cleaning Rod For Rifle , Cleaning Rod For Slr , Empty Case Catcher , Empty Gunny Bag (Jute) , Engraver Machine For Metal Black+Decker , Firing Testing Box , Funnel , Girish For Rifle , Gunny Cloth , Hassian Cloth , Human Target Paper , Iron Target (Musketry Practice) , Jute Cotton , Lead For Seal , Letter Metal Punch (0-9) 10Mm , Letter Metal Punch (0-9) 6Mm , Letter Metal Punch (A-Z) 10Mm , Letter Metal Punch (A-Z) 6Mm , Magnifying Glass , Marble Paper (Black) , Meltra Head Hammertaparia , Metal Mug , Metal Pliers Bigtaparia , Metal Pliers Smalltaparia , Mini Electronic Rotary Tool , Mt Case Counting Board , Number Of Punch (0 To 9) , Pull Through (Double) , Pull Through (Single) , Pull Through (Weight) , Rifle Rack For Ak-47 (Wooden) , Rifle Rack For Carbine (Wooden) , Rifle Rack For Insas (Wooden) , Rifle Rack For Rifle (Wooden) , Rifle Rack For Slr (Wooden) , Rifle Rack Sal Wood( H-4 Ft., L-4 Ft., W- 1.6Ft.) , Seal Coil , Seal Punch Machine , Seal Wire , Stamp Paper (Brown) , Stamp Paper (One Side Black & Other Side White) , Steel Coil For Seal , Sword Ips , Sword Wbap , Sword Wbp , Table Vice With Horse , Target Frame (1×1) , Target Frame For Revolver , Target Frame For Rifle , Target Frame For Snap Shooting , Target Head (1×1) , Target Head Paper , Target Human Face , Target Human Full Body , Target Paper 4×4 , Target Paper Figure Eleven , Target Paper Full Figure For Revolver , Vernier Caliper , Vernier Caliper (Digital) , Vice (Iron) , Waste Cotton , White Canvase Set For Revolver , Wooden Chauki (6 X 4) H-1, Leg 4X4 , Wooden Rifle Rack (Wall Fixing , Sal Wood) , Ankletwhite (Rexine) Standerd , Anniversary Medal , Belt Darktan Leather Withmonogram , Embroidery State Emblem For Pagri , Gloves White (Cotton) , Hackle , Jhalor , Komor Bandhani , Neck Bandhani (Scarf) , Pagri , Purbi Medal , Wrist Band , Abdomen Guard Ss , Absorbent Cotton (15 Gm.) , Absorbent Guaze , Badminton Netcosco , Badminton Racketyonex , Balling Shoe , Bandage Cotton 1.5 Inch , Band-Aid , Basket Ball , Basket Ball Post Wall Mount , Batter Chest Guardss , Batter Glovesss , Batting Pad / Leg Guardss , Batting Shoe , Billiard Pool Balls , Billiard Pool Stick , Billiard Pool Table , Billiard Pool Table Stand , Boot For Footballnivia , Boot For Footballpuma , Bronze Plating Medal , Cap Pick , Cap Round Shed , Carrom Board (48×48)Jtc , Carrom Board (48×48)Korners , Carrom Board (52×52)Jtc , Carrom Board (52×52)Korners , Carrom Board Stand , Carrom Coin Plastic , Carrom Coin Wooden , Corner Flag , Corner Flag Stand , Crepe Bandage 7.5 Cm , Cricket Ball Deuce Sg , Cricket Bat Deuce Sg , Cricket Bat Tennis Ss , Cricket Helmet Mind 2.0 Xl Size , Cricket Helmet Sg Blazetechxl Size , Cricket Helmet Shrey Pro Guard Steel 2.0 Xl Size , Cricket Helmet Ssxl Size , Cricket Tennis Ball Cosco , Decoration Flag Big , Decoration Flag Small , Discuss Big , Discuss Small , Elbow Guardss , Flower Bouquet (Big) For Vip , Flower Bouquet (Small) , Flower Bouquet (Stick Type) , Footballadidas , Footballcosco , Footballjersey , Footballnivia , Goal Keeper Gloves , Gold Plating Medal Big , High Jump Bar , High Jump Stand Wooden , Hockey Ball , Hockey Stick , Ice Bag Boltfit , Ice Gel Boltfit , Javelin Allm. , Javelin Cane , Jersey With Pant , Kone Big , Kone Small , Lawn Tennis (Head) , Lawn Tennis Ball , Lawn Tennis Bat Cosco , Lawn Tennis Bat Wilson , Lawn Tennis Bat Yonex , Line Track Machine , Linesmen Flag , Mashal , Measurement Stand Iron , Measurement Tape 100 Ft. , Measurement Tape 300 Ft. , Measurement Tape 5 Ft. , Measurement Tape 50 Ft. , Memento (Extra Large) , Memento (Large) , Memento (Medium) , Memento (Small) , Net For Goal Post , Pt Shoes , Rellay Button , Running Shoes Adidas , Running Shoes Puma , Short Put Big , Short Put Small , Shuttle Cockyonex , Silver Plating Medal , Sing Guard For Football , Skipping Rope , Socks , Socks For Football , Sport Shoespuma , Sportscap Normal , Sports Capadidas , Sports Cappuma , Sports Official Cap , Sports Shoesnike , Sports Shoes Adidas , Stop Watch , Stretcher (Folding) , T- Shirt (Full Sleeve) , T- Shirt (Half Sleeve) , Table Tennis Angle - Iron , Table Tennis Angle - Wood , Table Tennis Ball Gki , Table Tennis Bat Gki , Table Tennis Boardbuterfly , Table Tennis Net Buterfly , Tag Ofwar Rope , Thai Guard , Track Suit (Upper & Lower) Shivnaresh , Track Suit (Upper &Lower)Adidas , Track Suit (Upper &Lower)Nike , Trophy (Extra Large) , Trophy (Large) , Trophy (Medium) , Trophy (Small) , Victory Stand , Volini Spray , Volley Ballcosco , Volley Ballnivia , Volley Ball Net Cosco , Water Bottle (1Ltr.)Cello , Water Bottle (1Ltr.)Milton , Water Bottle (250 Ml.)Cello , Water Bottle (250 Ml.)Milton , Water Bottle (2Ltr.)Cello , Water Bottle (2Ltr.)Milton , Water Bottle (500 Ml.) Cello , Water Bottle (500 Ml.) Milton , Whistle , Wicket , Wicket Bell , Wicket Keeper Glovesss , Wicket Keeper Padss , Yoga Mat , Yoga Mat Carry Bag , Bavistin Powder 100 Gm. , Bone Dust , Cowdung , Cutting Powder , Daithen 100 Ml. , Earthenflower Tub 12 , Earthenflower Tub 15 , Earthenflower Tub 24 , Earthen Flower Tub 10 , Fertilizer Bone Dust , Fertilizer Dap , Fertilizer Horn Dust , Fertilizer Neem Dust , Fertilizer Phosphate , Fertilizer Potash , Fertilizer Sufala , Fertilizer Urea , Flower Sapling Plant , Folidon Powder , Gamaxine Powder , Garden Spray Machine , Metacide 100 Ml. , Mustard Cake , Roundup 1 Ltrs. , Scissor For Gardening , Sona Fertilizer , Sulphate , Thaidon 100 Ml. , Ustaad 100 Ml. , Water Jhari Metal , Water Jhari Pvc , Abd. Machine/Press , Adjustable Abd. Bench , Barbell , Bicep Curl , Cable Cross System , Chin Up Bar , Dumbbellpvc Core 10 Kg , Dumbbellpvc Core 2 Kg , Dumbbellpvc Core 4 Kg , Dumbbellpvc Core 5 Kg , Flat Press Bentch , Gym Ball Kcv , Gym Flat Bench , Gym Mat Kcv , Hack Squat , Horizental Plate Rack , Incline Bench , Incline Press , Leg Curl , Leg Extension , Leg Pull Down , Med. Ball Rubberise- 1 Kg. , Med. Ball Rubberise- 10 Kg. , Med. Ball Rubberise- 6 Kg. , Med. Ball Rubberise- 8 Kg. , Med. Ball Rubberise - 2 Kg. , Med. Ball Rubberise - 3 Kg. , Med. Ball Rubberise - 4 Kg. , Med. Ball Rubberise - 5 Kg. , Multi Hip , Multigym (12 Stations) , Multigym (16 Stations) , Pull Up Assistance Band , Push Up Bar , Rod Stand , Seated Chest Press , Seated Shoulder Press , Tricep Extension , Traffic Shoulder Light , Traffic Signal Stick Light Rechargable(Red & Green) , Vertical Butter Fly , Weight Plate (Rubber Coated) From 1.25 Kg. To 2.5 Kg. , Weight Plate (Rubber Coated) From 10 Kg. To 25 Kg. , Weight Plate (Rubber Coated) From 2.5 Kg. To 5 Kg. , Weight Plate (Rubber Coated) From 25 Kg. & Above , Weight Plate (Rubber Coated) From 5 Kg. To 10 Kg. , Weight Plate (Rubber Coated) Upto 1 Kg. , Aluminium Cane , Bothi Iron , Bowl Big Bone China , Bowl Bone China (Normal Size) , Bowl Medium Bone China , Bowl Small Bone China 6 Pcs , Bowl With Cover (As Per Sample) , Bucket (Aluminum) 11 , Bucket (Aluminum) 9 , Bucket (Gi) 10 , Bucket (Gi) 12 , Bucket (Steel) 10 , Bucket (Steel) 12 , Casserole Big 2000Ml Cello , Casserole Big 2000Ml Milton , Casserole Big 2000Ml Sumeet , Casserole Big Steel 2000Ml Cello , Casserole Big Steel 2000Ml Milton , Casserole Big Steel 2000Ml Sumeet , Casserole Small 1200Ml Cello , Casserole Small 1200Ml Milton , Casserole Small 1200Ml Sumeet , Chaki & Belna , Chimta (Big) , Chimta (Small) , Curry Bowl (Steel) , Dabu Hata Big (Iron) , Dabu Hata Big (Steel) , Dabu Hata Small (Steel) , Dekchi With Lid (Aluminum) , Dekchi With Lid (Steel) , Dish (Steel) , Gamla (Aluminum) , Gamla (Steel) 10 , Gamla (Steel) 14 , Gamla (Steel) 18 , Hamandista , Handi With Lid (Aluminum) , Handi With Lid (Steel) , Hata Steel (Spoon Type) , Hot Tiffin Carreier , Hot-Pot 2 Ltr.Cello , Hot-Pot 2 Ltr.Milton , Hot-Pot 5 Ltr.Cello , Hot-Pot 5 Ltr.Milton , Hot-Pot 5 Ltr. Steel Cello , Hot-Pot 5 Ltr. Steel Milton , Hot-Pot 5 Ltr. Sumeet , Jharna Hata Big , Jharna Hata Small Steel , Karai (Aluminum) , Karai Iron (Dhalai) , Karai Iron (Petai) , Kettle (Aluminum) Big , Kettle (Aluminum) Small , Khunti (Iron) Big , Khunti (Iron) Small , Khunti (Steel) Big , Khunti (Steel) Small , Lunch Carrier Milton , Meal Can (Aluminum) , Meal Can (Steel) , Mug (Aluminum) , Non-Stick Frying Panhawkins , Non-Stick Frying Panprestige , Non-Stick Frying Pan Induction Baseprestige , Non-Stick Frying Pan Induction Base Hawkins , Non-Stick Karaihawkins , Non-Stick Karaiprestige , Non-Stick Karai Induction Basehawkins , Non-Stick Karai Induction Baseprestige , Non-Stick Tawahawkins , Non-Stick Tawaprestige , Non-Stick Tawa Induction Basehawkins , Non-Stick Tawa Induction Baseprestige , Nowkawith Handle Alluminium , Nowka (Gi) 20 No , Oil Pot Small Steel , Picnic Hotpotcello , Presser Cooker10 Ltrs. Hawkins , Presser Cooker10 Ltrs. Prestige , Presser Cooker10 Ltrs. Shyam , Presser Cooker 1 Ltrs (Induction Base)Hawkins , Presser Cooker 1 Ltrs (Induction Base)Shyam , Presser Cooker 1 Ltrs.Hawkins , Presser Cooker 1 Ltrs.Prestige , Presser Cooker 1 Ltrs.Shyam , Presser Cooker 2 Ltrs Hawkins , Presser Cooker 2 Ltrs Shyam , Presser Cooker 2 Ltrs.Induction Base Hawkins , Presser Cooker 2 Ltrs.Induction Base Prestige , Presser Cooker 2 Ltrs.Induction Base Shyam , Presser Cooker 3 Ltrs.Hawkins , Presser Cooker 3 Ltrs.Prestige , Presser Cooker 3 Ltrs.Shyam , Presser Cooker 5 Ltrs.Hawkins , Presser Cooker 5 Ltrs.Prestige , Presser Cooker 5 Ltrs.Shyam , Presser Cooker 5 Ltrs. (Induction Base) Hawkins , Presser Cooker 5 Ltrs. (Induction Base) Shyam , Roti Jali Grill , Salad Tray , Sarashi Iron , Sarashi Steel , Saucepan With Handle Induction Base Cello , Saucepan With Handle Steel Cello , Saucepan Without Handle Steelcello , Sauces Pot With Spoon Cello , Shil Nora , Spice Tub , Spoon For Curd , Spoon For Rice , Spoon For Spice , Tawa Big (Iron)Maha Laxmi , Tawa Big (Iron)Samrat , Tawa Big Aluminium Maha Laxmi , Tawa Big Aluminium Samrat , Tawa Small (Iron)Maha Laxmi , Tawa Small (Iron)Samrat , Tawa Small Aluminium Maha Laxmi , Tawa Small Aluminium Samrat , Tiffin Carreier Steel Big (4 Bati) Milton , Tiffin Carreier Steel Big (5 Bati ) Milton , Tiffin Carreier Steel Small (3 Bati)Milton , Tiffin Carreier Steel Small (4 Bati)Milton , Tray ( Big)Alluminium , Tray ( Small)Alluminium , Vegetable Tub , Fluorescent Jacket , Fluorescent Tape , Guard Wall With Wheel , Gum Boot For Traffic , Hand Signal For Traffic (Battery Operated) , Iron Pole For Traffic Signal , Iron Removal Vessel Filter(Jindal) , Iron Removal Vessel Filter (Apex) , Iron Removal Vessel Filter (Tata) , Led Hand Held Signal Light , Movable Barrier (Type 1) With Clamps , No Entry Board Iron Made With Rectro Reflecting Sticker , No Entry Fluorescent Tape5 , No Parking Board Iron Made With Rectro Reflecting Sticker , Retro Reflective Jacket With Logo Print , Retro Reflective Sign Board With All Material Iron Structure & Fitting , Retro Reflective Words (With Adhesive) , Road Devider Cone (Fiber) , Road Divider Iron (With Paint And Quotation) , Road Making By Sand Filling Brick , Road Making Concrete With Supply Materials , Road Marking Paint , Traffic Boardiron Angle With Painting ( Different Matter) , Traffic Helmet For Constable White , Traffic Helmet For Officer White , Traffic Search Light , Umbrella Long Handle For Traffic Duty (K.C Paul) , Umbrella Long Handle For Traffic Duty (Mahendra Dutt) , Umbrella Long Handle For Traffic Duty (Orange) , Body Protective Gear (Khaki) , Cane Dhal , Cane Lathi 5 Ft. , Cane Lathi (3Ft.) , Frp Helmet , Frp Helmet Officer , Full Body Protective Gear (Robocop) , Hand Cuff (Steel - Bq) , Helmet Fiber Glass Kh. Colour , Poly Carbonate Dhal , Poly Carbonate Lathi , Prisoner Rope , Visor Helmet , 16- Channel Dvr Cp-Plus , 16- Channel Dvr Hik Vision , 16- Channel Dvr Dahua , 16 Mp Cc Cameracp-Plus Night Vision , 16 Mp Cc Cameradahua Night Vision , 16 Mp Cc Camerahik Vision Night Vision , 24 -Channel Dvr Cp-Plus , 24 -Channel Dvr Hik Vision , 24 -Channel Dvr Dahua , 4 Mp Cc Cameracp-Plus Night Vision , 4 Mp Cc Camerahik Vision Night Vision , 4 Mp Cc Camera Dahua Night Vision , 4 Mp Ip Micro Sd Slot Camera , 16 Mp Ip Micro Sd Slot Camera , 4 Mp Number Plate Recognition Camera , 8 Mp Number Plate Recognition Camera , 6Mp Bullet Cctv Camera Cp-Plus , 6Mp Bullet Cctv Camera Hik Vision , 6Mp Bullet Cctv Camera Dahua , 6Mp C-Mount Cctv Camera Cp-Plus , 6Mp C-Mount Cctv Camera Hik Vision , 6Mp C-Mount Cctv Camera Dahua , 6Mp Dome Cctv Camera Cp-Plus , 8 - Port Switch , 8 Mp Cc Camera Cp-Plus , 8 Mp Cc Camera Hik Vision Night Vision , 8 Mp Cc Cameradahua , 8-Channel Dvr Cp-Plus , 8-Channel Dvr Hik Vision , 8Mp Bullet Cctv Camera Cp-Plus , 8Mp Bullet Cctv Camera Hik Vision , 8Mp Bullet Cctv Camera Dahua , 8Mp C-Mount Cctv Camera Cp-Plus , 8Mp C-Mount Cctv Camera Hik Vision , 8Mp C-Mount Cctv Camera Dahua , 8Mp Dome Cctv Camera Cp-Plus , 8Mp Dome Cctv Camera Hik Vision , 8Mp Dome Cctv Camera Dahua , Audio Catcher , Bnc Connector , Body Camera Miufly , Body Camera Transcend , Body Camera Motorola , Body Camera Hikvision , Box At Poll , Cat-6 , Cctv Cable Hik Vision , Cctv Cable Cp-Plus , Cctv Cable Toshiba , Dc Connector , Electric Box , Fibre (Mtr) , Hdd 1 Tb Sea-Gate , Hdd 1 Tb Wd , Hdd 1 Tb Toshiba , Hdd 2 Tb Sea-Gate , Hdd 2 Tb Wd , Hdd 2 Tb Toshiba , Hdd 4 Tb Sea-Gate , Hdd 4 Tb Wd , Hdd 4 Tb Toshiba , High Defination (Hd) Cc Camera Hik Vision , High Defination (Hd) Cc Camera Cp-Plus , High Defination (Hd) Cc Camera Dahua , Media Converter , Monitor 48 (Samsung) , Monitor 48 (Hire) , Monitor 48 (Panasonic) , Monitor 52 (Samsung) , Monitor 52 (Hire) , Monitor 52 (Panasonic) , Monitor 65 (Samsung) , Monitor 65 (Hire) , Monitor 65 (Panasonic) , Interactive Led Panel 65(Lg) , Interactive Led Panel 65(Samsung) , Interactive Led Panel 65(Sony) , Interactive Led Panel 85(Lg) , Interactive Led Panel 85(Samsung) , Interactive Led Panel 85(Sony) , Nvr 16 Channel , Pigital , Power Cable , Rj - 45 , Routernet-Gear , Routertp-Link , Router D-Link , Slip , Smps 10 Amp Gigabyte , Smps 10Amp Parasnath , Smps 10Amp Toshiba , Smps 20 Amp Gigabyte , Smps 20Amp Parasnath , Smps 20Amp Toshiba , Spf , Tj Box , Ups - 1 Kv , Web Camera (Cp Plus) , Web Camera (Logitech) , Web Camera (I-Ball) , Web Camera (Hp) , Memory Card - 128 Gb (Sandisc) , Memory Card - 128 Gb (Kingston) , Memory Card - 128 Gb (Hp) , Memory Card - 256 Gb (Sandisc) , Memory Card - 256 Gb (Kingston) , Memory Card - 256 Gb (Hp) , 3 Ply Cotton Mask , Air Fumigant And Disinfectant Liquid , Anti-Pollution Mask , Apron , Ayush Kwath 100 Gm. , Disinfectant Spray Machine (Foggy) Toshi , Face Shield , Forehead Thermometer Gun Dr. Trust , Garbage Disposal Bag , Hand Rub 100Ml Microgen , Hand Rub 500Ml Microgen , Mask N-95 , Mask Surgical , Ppe Kit , Pulse Oximeter Dr. Trust , Rapid Test Kitcovi Self , Sanitizer 100 Ml.Dettol , Sanitizer 100 Ml.Lifebouy , Sanitizer 150Ml. Lifebouy , Sanitizer 150Ml.Dettol , Sanitizer 250 Ml. Lifebouy , Sanitizer 250 Ml.Dettol , Sanitizer Dispenser Stand (For Office Gate) , Sanitizer Liquid (5Ltr) Lifebouy , Sanitizer Liquid (5Ltr) Savlon , Sanitizer Spray Gun Bottle Big , Sanitizer Spray Gun Bottle Small , Sodium Hypochlorite Liquid , Bed Sheet Washing & Iron , Big Flag Dry-Washing , Big Towel Washing , Blanket Dry Wash , Carpet Dry-Washing , Ceremonial Dress Washing , Curtain Cloth Washing & Iron , Decoration Flag Washing , Hand Gloves Washing , Pillow Cover Washing & Iron , Small Flag Dry-Washing , Small Towel Washing , Table Clothwashing , Ac Compressor Change , Ac Cooling Coil Change , Ac Fan To Motor Change , Ac Machine Circuit Change , Ac Machine Condenser Change , Ac Machine Gas Install , Ac Machine Remote Repairing , Ac Machine Servicing , Almirah Repairing Major , Almirah Repairing Minor , Almirah Steel Painting , Aluminum Window Glass Setting (6 Mm) , Amplifier Repairing , Aqua Guard Full Service (Amc) , Aqua Guard Repairing , Aquarium Cleaning Charges , Axe Sharping , Body Camera Repairing , Box (Speaker) Repairing , Brass Stand Repairing , Brass Tub Repairing , Brush Cutter Machinefull Servicing With Mobil Change & Repair , Brush Cutter Machine Servicingcharge , By-Cycle Repairing , Calling Bell Repairing , Camera Repairing , Cane Dhal Repairing , Ceiling Fan Bearing Repairing , Ceiling Fan Coil Change , Ceiling Fan Coil Repairing , Ceiling Fan Condenser Repairing , Ceiling Light Repairing , Chain Saw Machine Full Servicing Charge , Collapsible Gate Repairing , Cooler Machine Repairing , Cordless Repairing , Cricket Helmet Repairing , Cushion Chair Repairing , Door Closer Repairing , Door Lock Repairing , Door Repair With Supply All Material , Dragon Light Repairing , Drill Machine Carbon Repairing , Drill Machine Motor Repairing , Electric Kettle Repairing , Electric Weight Machine 20Kg50kg Repair , Emergency Light Repairing , Exhaust Fan Repairing , Fog Spray Machine Repair , Freeze Repair , Garden Umbrella Repairing , Gasoven Repairing , Geyser Repairing , Gf Helmet Painting , Gf Helmet Repairing With Thermocol , Glow Sign Board Minor Repairing , Grass Cutter Machine Repairing , Grinder Machine Repairing , Hand Held Motorized Saw Machine Repairing , Handi Cam Repairing , Hansua Sharping , Hedge Trimmer Machine Repair , Helmet Repairing And Painting , Hurricane Repairing , Inflatable Tower Light Repairing , Iron Cot Major Repairing & Painting , Iron Cot Minor Repairing & Painting , Iron Cot Painting , Iron Cot Paya Repairing , Iron Cot Sheet Change , Iron Tank Repair , Kaste Sharping , Kent Water Purifier Full Servicing , Khurpe Sharping , Kitchen Chimney Servicing Charge , Labour Charge For Carpenter , Labour Charge For Mason , Lawn Mower Full Servicing With Mobil Change & Repair , Lawn Mower Machine Sevicing Chharge , Led Metal Repairing , Loud Hailer Repairing , Metal Cabinet Change , Metal Glass Change , Metal Holder Change , Metal Repairing , Metal Set Repairing , Microphone Repairing , Microven Repair , Microwave Oven Repair , Mike Repairing , Mixer Machine Repairing , Mosquito Gun Smoke Machine Repair , Pedistrial Fan Coil Binding With Repairing , Pipe Line Repair With Supply Articles , Pipe Line Washing , Poly Carbonate Dhal Repairing , Pvc Door Repairing , Revolving Chair Repairing , Rewind Of Motor , Rewinding Of Fan Coil , Sabol Sharping , Sarch Light Repair , Scissor Sharping , Septic Tank Cleaning , Sofa Set Repairing , Spade Sharping , Stand Fan Bearing Repairing , Stand Fan Coil Repairing , Stand Fan Repairing , Stop Watch Repairing , Stove Repairing With Burner Change , Sword Electro-Plating , Sword Repairing , Misc. Goods , T. V. Cabinet Change , T. V. Circuit Repairing , T. V. Picture Tube Change , T. V. Power Board Repairing , T. V. Repairing , Tea Container Repairing , Torch Light Repairing , Tub-Well Boring 200Ft , Tub-Well Boring 650Ft , Tub-Well Repairing , Tulu Pump Bearing Charge , Tulu Pump Capacitor Change , Tulu Pump Coil Change , Tulu Pump Motor Repairing , Tulu Pump Repairing , Tulu Pump Water Sil Change , Umbrella Repair With Cloth Change , Umbrella Repair With Handle Change , Unit Repairing , Wall Clock Repairing , Washing Machine Repair , Water Cooler Repair , Water Tank Cleaning 1000Ltr , Water Tank Cleaning 750Ltr , Weight Machine Repairing , Window Repair With Supply All Material , Wooden Almirah Polishing , Wooden Almirah Repair Major , Wooden Almirah Repair Minor , Wooden Bench Major Repair , Wooden Bench Minor Repair , Wooden Bench Polishing , Wooden Chair Major Repair , Wooden Chair Minor Repair , Wooden Chair Polishing , Wooden Cot Repairing , Wooden Dining Table Polishing , Wooden Table Major Repair , Wooden Table Minor Repair , Xerox Machine Repair , Ac Split (1 Ton) With Installation , Ac Split (1.5 Ton) With Installation , Ac Split (2 Ton) With Installation , Ac Window (1 Ton) With Installation , Ac Window (1.5 Ton) With Installation , Ac Window (2 Ton) With Installation , Air Cooler , Alu Handibig , Alu Koraibig , Alu Nowka Medium , Alu Tub With Handel Big , Bamboo Fencing. Good Quality Of Bamboo7.5Cm To10cm Dia With Rope. , Bed Cover , Brass Handi With Lid Big , Buffet Table , Bulb 100 Wt. With Installation , Bulb 200 Wt. With Installation , Carpet Special Blue/ Green/ Red/ Orange , Cctv Camarawith Accessories And Installation , Ceiling Fan With Installation , Chair Plastic With Handle , Chair Plastic Without Handle , Coffe Machine , Dias10 Height With 30Mm Thick Plank Wooden Shuttering With Proper Props To Perform The Proper Staging Including Covering With Mats. , Dressing Of Ground Including Cutting And Filling Of Earth. , Drone Camera Hire With Operator , Drop Gate With Good Quality Bamboo. Entire Period , Exhaust Fan With Installation , Extension Cord 50 Mtrs. With Installation , Febricated Temporarytoiletshade ( Rain Proof Top) , Febricated Temporary Kitchen Shade(Rain Proof Top) , Febricated Temporary Shade/ Pandal ( Rain Proof Top) , Floor Mounted Panel Withset Appropriate Size.200Amp Tpn Main Switch 200Amp4p Change Over Switch,200Amp 4P Aicable Busber Changer,32Amp Db Main Switch. , Folding Cot , G,C.I Sheet Fencing Making With Strong Bamboo. , Garden Umbrella , Gas Oven Big , Generator With Fuel And Operator With Installation (25 Kv) , Generator With Fuel And Operator With Installation (5 Kv) , Halozen Light 500 Wt. With Installation , Installation Of Tube Welland Making Platform. (For Entired Period) , Iron Hatabig , Iron Khuntibig , Iron Korai Big , Latrine (Male/Female). (Size 4/3 Depth 5 With Concrete Slab And Pan And Good Quality Polythene Shed Covering Per Nos(For Entire Period) , Led Lamp 75 Wt. With Installation , Making Charge Of Curtain , Mattress With Cover (7 X 3) , Metal Light(Led) 100 Wt. With Installation , Metal Light 400 Wt. With Installation , Pillo With Cover , Plastic Dustbin 50 Lts. , Plastic Terpolin , Replace Ofpipe Pvc 1 With Supply All Materials , Replace Of Pipe Pvc 2 With Supply All Materials , Room Cleaning & Dusting , Side And Roof Coveringstructure With Good Quality Of Decorative Cloths . , Side Coveringstructure With G.C.I Sheet. , Side Coveringstructure With Good Quality Hessian. , Sofa , Sound System With Operator With Installation , Stand Fan With Installation , Steel Bucket , Steel Gamlamedium , Steel Gamlasmall , Steel Hatasmall , Table Plastic , Tableau (Vehicles Pick-Up Van With Decoration) , Tea Table , Temporary Sentry Post With Sand Bag Per Post.(For Eentire Period) , Temporary Structuregood Quality Bamoo With Approved Quality Water Proof Tarpaulin Over Roofincluding Fitting Fixing Proper Level. , Tower Ac Machine With Installation , Tube Light Set With Installation , Tv Set With Set-Top Box And Connection With Installation , Urinal (Male/Female). , Video Graphy Hiring , Vip Chair/ Ornet Chair. , Wall Fan With Installation , Water Dispenser , Water Drum 200 Ltr. , Water Drum 50 Ltr. , Water Drum Steel 50Ltr , Water Tank 1000 Ltr. With Fitting , Water Tank 500 Ltr. With Fitting , Wooden Pole For Metal Lamp.
Contract Date: Mar 14, 2026 Contract Value : 3.11 Crore
Statutory Bodies & Commissions/Committees No of Bidders 11
West Bengal View Result →
47.
Heavy Industries and Public Enterprises #9788623 Price Bid
Tender For Civil And Mep Works For Setting Up Hindlabs Minor Lab, Mangaldoi, Assam; 2 Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etc complete. 3 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand). 4 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 5 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 6 Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work 7 Providing and laying premium Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile600 x 1200 mm. 8 Providing and laying premium vitrified wall tile in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. 9 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid. 10 Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. 11 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap 12 Providing and fixing uplasticised PVC connectionpipe with brass unions: 45 cm length15 mm nominal bore 13 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe32 mm dia 14 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge Concealed work, including cutting chases and making good the wall etc. 15 mm pipe 10kgf/cm2 15 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work,including cutting chased and making good the wall etc. 20 mm pipe 12 Kgf/cm2 16 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2 17 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 10 kgf/cm2 18 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed on wall 19 Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall 20 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2 21 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow 22 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend 23 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee 24 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl 25 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia End cap 26 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap 27 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend 28 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee 29 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 30 For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 31 Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-Charge.Powder coated minimum thickness 50 micron aluminium 32 Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/ Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600Upto 5 mm depth and 5 mm width 33 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides 34 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) 35 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm 36 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper 37 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 38 Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm 39 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 40 Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer- in-charge. 41 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm 42 Providing and fixing bright finished brass handles with screws etc. complete:125 mm 43 Furniture 44 Supply of phlebotomy chair with optimum design made up of MS Power coated frame and up upholstery type seat,back rest and arm rests.Both side arm rest should be with height and position adjustable system and all as per the instruction of Engineer in charge. 45 Supply and erection of Airport type 3 seater waiting chair with powder coated chromium finish having minimum dimensions 1675mm length X 710mm width X 775mm total height and 400mm seat height . Seat: High quality cold rolled 1.2mm thick steel perforated sheet pressed and welded to form the shape. Arm & Leg: High quality 1.2mm thick MS Tube / Sheet . Cross bar: High quality cold rolled 2mm thick steel sheet pressed and welded to form the shape. 46 Supplying and fixing of lab work table with 18 mm thick edge moulded granite top supported over 18mm thick marine ply wood of 2500mm,L x 1200mm,W x 850mm, H and powder coated GI frame of section size not less than 50x50x1.5 mm including and providing 4 nos under storage movable cabinents of size 600mm,L x 450mm,D x 750 mm,H and powder coated steel sheet of thickness not less than 1mm with 1 drawer and partition bottom storage space with door including drawer channels, individual locks andhandles all as per the approved drawing and instructions of Engineer in charge 47 Overhead Storage: - Providing and fixing overhead storage unit with minimum 18 mm thick pre-laminated medium density fiber board exterior grade (Grade-I) IS: 14587:1998 marked with one side decorative and other side balancing lamination. cupboard shutters edge to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickel plated bright finishing M.S. piano hinges conforming to IS:3818 marked with fixing chromium plated brass 50 mm cupboard or wardrobe knobs, special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. Only Front Elevation will be measured. 48 L-Type workstation of overall size (1350 * 600)mm + (1000 * 450)mm X 750 mm (L X D X H) and pedestal unit made up of 18 mm thick Exterior Grade-I MDF board on all sides conforming to IS:14587 from approved makes such as Century/Greenply/Fineply or equivalent with decorative laminate on both side and all edges to be fixed with 2mm thick pvc edge beading. One three-drawer modular pedestal unit of minimum size 450 mm (W) X 500 mm (D) X 650 mm (H) all with retractable key board tray, drawer channels, hinges, handles, individual locking system, and all necessary fittings and the workstation should have an electrical flip box with 2 nos universal power socket & 1 no data socket etc and cable management tray. All work as per the approved design and instruction of the Engineer-in-Charge/Architect. 49 Providing and erection of reception counter table of length 1200 mm and first level should be provided at a height of 750 mm and width 600 mm and the second level at a height of 1050mm from base with a width of 300. The table made of 18mm thick pre laminated Medium Density board of exterior grade (Grade I)IS: 14587:1998 with decorative laminated finish on both sides and 2 mm thick PVC beading on all edges, including electrical flip box, cable measurement tray, grommets with 3 nos universal power socket and ethernet port, three drawer pedestal unit with drawer channel, handles, hinges, lock all complete as per approved drawing and installation of Engineer in charge/Architect. 50 Lab work bench -The work bench top made up of 18mm thick granite top edge moulded over 18 mm thick marine plywood and GI Powder coated frame work of section size not less than 50x50x1.5mm. The width of the table shall be 750mm and height shall be 850mm. The frame provided with level adjusting screws fixing accessories ,carriage of material all complete as per the approved drawings and direction of Engineer in charge.Note Only length of the table shall be measured for making payment. 51 Supply of moulded plastic pantry table of size 1520 mm (L) × 760 mm (W) × 750 mm (H), on MS powder coated frame work made and table top shall be made from high-quality, washable and durable plastic, weather-resistant and featuring double- layer construction to ensure greater strength. The table shall be lightweight, easy to carry, easy to assemble, and of folding type for ease of operation. The supply shall also include six (6) moulded plastic chairs of size 410 mm (W) × 550 mm (D) × 880 mm (H), made of sturdy, washable, weather-resistant, and suitable for both indoor and outdoor usage. 52 Slotted Angle Racks : Supply and errection of Powder coated slotted angle metalic rack having min 8 shelfs made up of min 40 X 40 X 2 mm size rolled steel angle posts shall have 8-mm diameter holes provided at 50-mm centre to centre. Metal shelves shall be made from mild steel sheets not less than 1.0 mm in thickness and with sufficient stiffners. Shelves shall have lipped flanges width of flange being 30 mm and depth of lip 15 mm .Min size of rack 900mm Length X 300mm Depth X 2000mm Height. 53 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm,with swan neckfaucet with pipe in let and drain provision, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm 54 Counter Height Stools :Supply and erection of counter height stools ( bar stools ) of following specifications: Revolving adjustable Chrome plated steel body chairs with resistance to the corrosion. Cushion Seat with Lift mechanism for Adjustment of height. Minimum height 750mm before expansion. Medium Back rest and arm rest. Item shall be of reputed make. 55 Revolving Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 56 Supply and installation of visitors chair Medium Back, Mesh Back cushion seat with fixed supports made of 304 Stainless Steel/ powder coated MS of approved colour or shade as per the instruction of the engineer in charge 57 Wiring 58 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 59 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface / recessedmedium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire 60 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface / recessedmedium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 61 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface / recessedmedium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 62 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 6 Sq.mm + 1 x 6 sq.mm earth wire 63 Fixtures 64 Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 3 pin 5/6 amps modular socketoutlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to beused in non residential buildings) 65 Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 6 pin 5/6 & 15/16 ampsmodular socket outlet and 15/16 amps modular switch, connection etc. as required 66 Supplying & fixing suitable size Gl box wih modular plate and cover in front onsurface or in recess including providing and fixing 25 A modular socket outlet and 25A modular SP MCB, C curve including connections, painting etc. asrequired. 67 Supply, Installation of surface mounted LED Tubelight. The luminaire should have CRI80 and CCT of both 6500K/5700K. The luminaire shall be compliant withIP20 and IK02 classification. Luminaire shall be designed to emit at least 3600nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattageof 30 Watts. The luminaire shall be designed so as to ensure lumen depreciation of upto 30% over 25k burning hours. The electronic driver used shall have a power factor 0.95 and THD. Make - Philips, Crompton, Wipro, Havells 68 Supply and Installation of surface/recess mounted LED Round/Square luminaire with CRCA housing suitable with fully diffused diffuser for general lighting in offic eareas. The luminaire should have CRI > 80 and CCT of both 6500K/5700K, Cool White Light. The luminaire shall be compliant with IP20 and IK02 classification.Luminaire shall be designed to emit at least 1000 nominal lumens and efficacy ofatleast 105 lumen/watt and Minimum system wattage of 10 -15 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. For light fittings to be installed in false ceiling, all required cuttings shall be made and damages shall be made good as per the direction of Engineer in charge. Make-Philips, Crompton, Wipro 69 Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 1200mm sweep - 5 star rated, 3 blade ceiling fan complete with 300mm down rod, canopies, shackles. 70 Supplying and fixing two module stepped type electronic fan regulator on the existingmodular plate switch box including connections but excluding modular plate etc. as required. 71 Supplying, conveyance and Installation of 3 blade, 400 mm sweep, 1400 rpm Wall Mount Fan including frames and all mounting accessories complete. Recommended Make: USHA/ Havells/ Bajaj / Almonard or equivalent 72 Supplying, conveyance and Installation of 150 mm sweep,1800 rpm Exhaust Fanincluding frames and allmounting accessories complete. Recommended Make: USHA/Havells/Bajaj or equivalent 73 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 74 Supplying and fixing brass batten/ angle holder including connection etc. as required. 75 Supply, Installation of 12 Watt LED Bulb. 76 DB and Switchgear 77 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) 78 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 16 way, Double door 79 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 80 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 81 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 82 Supplying and fixing following rating, four pole, 415 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.63amps 83 Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.63 amps 84 Supplying and fixing Cable End Boxes (IP 43) suitable for following single poleand neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess,complete with testing and commissioning etc. as required.For 6 way, Double door SPN MCBDB 85 Cctv and Networking 86 Supply, Conveyance and Installing of 2MP IP Dome/Bullet Camera having 1/3Progressive Scan True Day and Night Colour IR Camera having effective pixel of 2MP, Video frame rate of 2MP @30FPS, Minimum illumination of 0.01 [email protected], 0lux@IR On, 20 M IR Range, 24 IR LED, AWB, AGC, BLC, 2D Noise reduction,with 3.6mm board lense, 12 VDC, PoE IP67 rated weatherproof performance. 1 year warranty. Make: Bosch/CP Plus/Honeywell or equivalent 87 Supply, Installation and Integration of 8 channel embedded Linux PoE, NVR (Network Video Recorder), having dual core embedded processor, must connect 8 channel IP cameras , should support min 2 SATA HDD each of 6TB and must recordvideo simultaneously, (Recording Type: Continuous, Motion Detection, Alarm, SmartEvent, Event Motion Detection, Alarm, Smart Event), Video Compression H.265(HEVC)/H.264+/H.264, 2 Year Warranty, Image quality should be maintainedthroughout the warranty period. Make: Bosch/CP Plus/Honeywell or equivalent 88 Supply and Installation of Network Switch. 8 Port PoE Switch 1000BASE-T Copper Ethernet PoE+ connections, 10M/100M/1G RJ-45 copper ports, 1000BASE-X Fiber SFP ports, 8 port Auto sensing 10/100/1000 Mbps PoE, minimum CPU memory 512 MB with 2 SFP/combo ports, Energy Efficient Ethernet (IEEE 802.3az). Make: Cisco/CP Plus/ Netgear or equivalent 89 Supply and fixing of 6U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete 90 Supply and Installation of 8TB hard disk 91 Supply and Installation of LED Color Monitor of minimum 32 inch screen, complete, UHD display Make: LG/Samsung/Panasonic or equivalent. 92 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable 93 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 94 Supplying and fixing RJ45 Outlet including cover plate, Keystone Jack and Gang box supporting, connection etc. as required 95 Air conditioning system 96 Supply, installation, testing and commissioning of Split Air Conditioner of followingcapacity and specifications: Consisting of high wall-mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of energy-efficient suitable rotary compressor for operation on single phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation and fixing of room (fan coil) unit on wall, standard 4m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1 inch dia drain PVC pipe with insulation up to 4 m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. (Make: Voltas, Blue Star, Hitachi, Carrier or equivalent). 2 TR 3 Star rated (inverter type AC) as per BEE 97 Supply, installation, testing and commissioning of Split Air Conditioner of following capacity and specifications: Consisting of high wall-mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of energy-efficient suitable rotary compressor for operation on singlephase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation and fixing of room (fan coil) unit on wall, standard 4 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1 dia drain PVC pipe with insulation up to 4 m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. (Make: Voltas, Blue Star, Hitachi, Carrier or equivalent). 1.5 TR 3 Star rated (inverter type AC) as per BEE 98 Supply and Installation of additional copper piping, cabling from indoor to outdoor and drain piping for air conditioning unit with proper insulation including all required on wall/above false ceiling complete 99 UPS 100 Supply, Installation, Testing and Commissioning of True on-line Double Conversion 6 KVA UPS system with 1:1 Crest Factor Single Phase Phase Input – SinglePhase Output. Inversion shall be Microprocessor controlled with instantaneous sine wave Control using IGBT. UPS shall have standard display features, alarms, safeties, etc Input Voltage range : a) Phase – Single Phase with ground b)Votage range 190 VAC – 250 VAC c)Input Frequency : 50/60 Hz d)Power Factor : 0.95 or above e)THD : less than 5% with full load Bypass f) Voltage Range & 200VAC & 240 VAC g) Frequency range – 45-55 Hz/55-65 Hz Output Voltage Range h)Voltage Range & 200VAC – 240 VACi)Frequency range & 50/60 Hz j)Voltage distortion & linear load = 2% k)Voltage distortion – nonlinear load = 5% l)Output waveform & pure sinewave m) Minimum Back up time : Continuous 60 Minutes at full load Rectifier shall be Full wave Type (Shall fully meet the specified input power requirements) Battery Type: Sealed Lead Acid Maintenance Free DC Voltage : 24/48/96V DC System, Battery Nos and capacity shall be designed for optimum storage space. Make: Liebert Vertiv/APC by Schneider/Numeric by Legrand 101 Visi Cooler and Refrigerator 102 Supply and Installation of 260 litre refrigerator, direct-cool model with a minimum 3-star BEE rating and stabilizer-free operation. It shall use eco-friendly refrigerant (R600a) and have a high-efficiency, low-noise compressor. The unit shall include toughened glass shelves, a vegetable crisper, bottle storage for 2L bottles, an internal freezer compartment, and a removable anti-bacterial gasket. It shall operate on 230V, 50Hz AC and include standard accessories such as an ice tray and egg tray. The refrigerator shall have 1-year comprehensive warranty and 10-year compressor warranty, with BIS certification. 103 Visi Cooler/Pharmacy refrigerator: Supply, installation and commissioning of lab/pharmacy refrigerator as per following specification: Upright Show case Coolers/refrigerators with Single Glass Door and Lock having 350-450 Liter capacity, Temperature range capability 1-10 degree Celsius with Digital Temperature Controller and Display, Minimum of 4 adjustable Shelve/Rack Recommended Make: BLUE STAR
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
48.
Defence #9749550 AOC
Tender For Provision Of Deficient Married Accommodation At Air Force Station Phalodi Boq (11 Aug 2025).; 1 NOTE: Schedule ‘A’ Part I to XII under Ser No. 1.00to 12.00 are prepriced by MES. Bidders shall insert their lumpsum amount in the green coloured field under Col-6 only. 2 Lump sum price worked outfor BUILDINGS/ STRUCTURES as listed in Sch A Part I. 3 Lump sum price worked out for EXCAVATION, EARTH WORK AND SITE CLEARANCE as listed in Sch A Part II 4 Lump sum price worked out for INTERNAL ELECTRIFICATION as listed in Sch A Part III 5 Lump sum price worked out for INTERNAL WATER SUPPLY as listed in Sch A Part IV 6 Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch A Part V 7 Lump sum price worked out for AREA DRAINAGE as listed in Sch A Part VI 8 Lump sum price worked out for ROAD/ PATH as listed in Sch A Part VII 9 Lump sum price worked out for FENCING/GATE as listed in Sch A Part VIII 10 Lump sum price worked out for EXTERNAL ELECTRIFICATION/STP as listed in Sch A Part IX 11 Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch A Part X 12 Lump sum price worked out forRAIN WATER HARVESTING as listed in Sch A Part XI 13 Lump sum price worked out for HOT WATER SUPPLY as listed in Sch A Part XII 14 SCHEDULE A PART - XIII MISCELLANEOUS ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signifies this fact only. Bidder shall insert their rates in Green filed under Col-6. 15 SITE CLERANCE & DEVELOPMENT 16 M & L for Surface excavation n.exc30 cm deep and averaging 20cm deep and getting out top layer arqanie soil without disturbing or destroy its texture and remove the same to a location specified and stored properly for relaying after the completion of building work exc 50m but n exc 250m complete all as specified and as directed 17 Relaying the soil excavated in Item no 13 to building site for landscaping and gardening complete all as specified and directed 18 S&F colour coaded plastic dustbins of 120 Litre capacity each in Green/Blue/Red in colour as directed by GE , made of high grade UV resistant polyethylene, suitable for segregation of biodegradable, recyclable, hazardous and sanitary waste bins to be durable , Light weight, weatherproof, easy to clean with tight fitting lids and clear identification lables complete all as specified and directed..Note :-Labelling on dustbin are as follows:a) Green color waste bin :- Bio degradable wasteb) Blue color waste bin :- Reusable/ Recycle waste c)Red color waste bin :- Land Fill waste 19 INTERNAL ELECTRIFICATION 20 S & F for wall mounted LED box type tube light fitting 4 x 20 watts industrial commercial interior batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouputboxtype fitting, 230 volts and intregrated electronic driverconnector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. 21 S & F forLED tube light fitting with aluminium housing 2 feet x 10 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cableof suitable sizefrom ceiling rose to fittingwith warranty option of 5 years from date of installationcomplete all as specified and as directed. 22 S & F forLED tube light fitting with aluminium housing 2 feet x 5 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cableof suitable sizefrom ceiling rose to fittingwith warranty option of 5 years from date of installationcomplete all as specified and as directed. 23 S & F for Decorative wall mounted luminaire made out of Nickle finesh square base with bend pipewith unbreakable globe glass suitable for LED bulb and provosion of LED bulb 10 watts complete all as specified and as directed. 24 S & F for ceiling fan, 230 Volts, 1200 mm sweep with mian air delivary 210 CFM, service value of the fan shall be greater than 6.1 (5 star rated) as per BIS with blades, down rod & other necessary accessories with brushless direct current motor (BLDC)with remote system and electrical connections from ceiling rose to fan teriminal complete all as specified and directed. 25 S & F for energy efficient exhaust fan of 225 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existing wall for fan base compelte all as specifiedand directed.(Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be includedin overall rate quoted). 26 S & F for energy efficient exhaust fan of 300 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existingwall for fan base compelte all as specifiedand directed.(Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be includedin overall rate quoted). 27 Supply, installation, commissioning and testing indoor type LT wall mounting Bldg panel board of suitable sizefactory made TTA panel, weather, dust & vermin proof indoor, double door, front openable, locking arrangements made out of 2.00 mm thick mild steel CRCA sheet including required comparment for fixing of four (12) Nos single phase smartmeter, MCCB and MCB and porviding glass view for reading of meter and providing rubber/ PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/ sleeves with maintained the colour code and copper strip/ wire busbar of suitable size to MCCB input and MCCB/ MCB output of suitable length for connection of cable from main busbar, angle iron 50 mm x 50 mm x 5 mm thick supporting frame including applying two coats of powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfacesfor 3 phase 4 wire system 415/ 440 volts grade including internal wiring connections for all outgoing / incomming cable,earthing teminals , danger plate, suitable PCC platform complete all as specified and directed 28 INCOMING(a) Copper strip busbar of suiable of capacity 200 Amps rating wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos.(b)MCCBIP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 100 Amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links -01 No.(c) Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch – 01 No(d)LED Neon indicator lamp (RYB) with holder,230/250 volts,AC -01 set (set of three) Make :- AE/L&TOUTGOING(a) MCB, Single pole & neutral, 40 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 12 Nos (Officers Accn)(b) MCB, single pole & neutral, 10 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 1 No (Stair case lighting)(c) Slot for fixing the three phase smart prepaid meter - 13 Nos (Cost of Smart meter cost will be paid seperately under respective itemly) 29 Supply, installation, commissioning and testing indoor type LT wall mounting Bldg panel board of suitable sizefactory made TTA panel, weather, dust & vermin proof indoor, double door, front openable, locking arrangements made out of 2.00 mm thick mild steel CRCA sheet including required comparment for fixing of four (07) Nos single phase smartmeter, MCCB and MCB and porviding glass view for reading of meter and providing rubber/ PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/ sleeves with maintained the colour code and copper strip/ wire busbar of suitable size to MCCB input and MCCB/ MCB output of suitable length for connection of cable from main busbar, angle iron 50 mm x 50 mm x 5 mm thick supporting frame including applying two coats of powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfacesfor 3 phase 4 wire system 415/ 440 volts grade including internal wiring connections for all outgoing / incomming cable,earthing teminals , danger plate, suitable PCC platform complete all as directed 30 INCOMING(a) Copper strip busbar of suiable of capacity 120 Amps rating wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos.(b)MCCBIP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 63 Amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links -01 No.(c) Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch – 01 No(d)LED Neon indicator lamp (RYB) with holder,230/250 volts,AC -01 set (set of three) Make :- AE/L&TOUTGOING(a) MCB, Single pole & neutral, 40 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 06 Nos (Officers Accn)(b) MCB, single pole & neutral, 10 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 1 No (Stair case lighting)(c) Slot for fixing the three phase smart prepaid meter - 07 Nos (Cost of Smart meter cost will be paid seperately under respective itemly) 31 M & L for maintenance free Chemical earthing of technology with copper bonded steel rod 3 mtr long 25.0 mm dia with 250-micron Copper bonded coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 holes of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material- polymer body & cover dimensions- 308 mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed. 32 Note:-(i) Earthing is to be done infront of the Engr-in-Charge.(ii)Test Results of earthing to be submitted by the contractor for all earthings.(iii)The Contractor shall have to give written guarantee for maintenance earth resistance of less than 1.0 Ohm for the period of 10 9ten) years after certified date of completion and shall bdeposited 2000/- per earthing as security deposit for a period of Ten (10) Years.(iv)Failing to maintain resistance of earthing less than 01.0 ohm , new earthing to be provided by the contractor with out any extra cost.(v)Necessary earth work, excavation shall be carried out in any type of soil strata, retuning, filling in and making good surronding area complete. 33 Supply and Installation of Smart Single Phase Meter of different makes (Not more than 33 % of a particular make) including polycarbonate boxes with transparent cover to view meter display with the following specifications:(a) AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 5A-60A, with 3200 impulses per KWh,LED forPhase presence & LED for Relay status, conforming to IS-16444 standard with inbuilt 865-867 MHz 6 Low PAN Mesh Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LCD based display only with compatible IP54 compliant polycarbonate box for outdoor mounting with optical port Provision on meter box. Meter Should support the following data : 15/30 min instantaneous data for Voltage, Current, Power factor, Power, Cumulative energy and frequency, monthly billing data & antitamper features. Load survey data for 45 days with 30 min integration period for kWh, Voltage, Current, frequency etc.Meter should have connect / disconnect functionality operable from prepaid billing software & shall show balance on displayThe meter should support open communication protocol DLMSwith the softwareNote :-(a) It should run the meter in both prepaid and postpaid mode(b) The meters should carry 5 year warranty.(c) OEM shall have own NABL accredited lab for testing meters as per IS 16444 and certification shall be provided during sample approval(d) The meter cost would include DCU/ Gateway and repeater cost for RF commuication meters 34 Supplying, Fixing, Commissioning and testing of configuration of cloud based prepaid software forwith following modules: (i) Meter Data Management Module: The meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. The system would support offline meter data entry.The meter data management system would capture and provide the following data:(a) 30min instantaneous data from all the meters for seven parameters- Cumulative Energy,Power, Current, Voltage, Power factor and Frequency.b) Monthly and quarterly billing survey data for cumulative energy and max demand, Load Survey Data, Tamper Events(ii) Communication module: The system should provide communication of energy data and bills via print, email.(iii) Meter Master Data : The system would support meter data repository. The system should support meter replacment process.(iv) Excel Export : The system would support export of metering and billing data in excel formatNote:- (i). Software will be compatible with all makes of smart meter & shall be CERT-IN certified from CERT approved vendors for any cyber security related threat & complying as per ENC guidelines.(ii) It shall also include recurring SMS charges, Email gateway integration charges, payment gateway charges for online meter recharge etc & shall be included in quoted rate for 2 years DLP period.(iii) Provision for comprehensive operation including periodic charges of telecom operator, smart meter billing from completion of work till the competion of defect liability period of 2 years.(iv) The software would be hosted on MEITY GCC approved server. 2 years hosting costs would be included. 35 INTERNAL WATER SUPPLY 36 S & Fchromium plated fancy type Angle cock with wall flange quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 37 S & FChromium plated fancy type two way Angle cock with wall flange quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 38 S & FChromium plated fancy type Bib cock with Aerator quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 39 S & FChromium plated fancy type Pillar cock with Aerator quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 40 S & FChromium plated fancy type Sink cock(wall mounted) with Aerator long shunk quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 41 S & F Chromium plated fancy type Wall Mixer 3 In 1 (flow rate 6 liter per minute) with flange Provision For Overhead Shower with 115mm Long Bend Pipe On Upper Side, Connecting Legs & Wall Flangescomplete all as specified and directed.Make - Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 42 SEWAGE DISPOSAL 43 Supply, laying and testing of 150mm internal diameter of double wall corrugated (DWC) high density polythylene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked(with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS 16098-2013 Part-2 complete all as specified and as directed. Note : Bedding of pipe shallbe provide as per theconstruction methods ,andshall be strictly compiled as per clause No A-4 of Annex A of IS 16098 Part II 44 Supply, laying and testing of 200mm internal diameter of double wall corrugated (DWC) high density polythylene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked(with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS 16098-2013 Part-2 complete all as specified and as directed. Note : Bedding of pipe shallbe provide as per theconstruction methods ,andshall be strictly compiled as per clause No A-4 of Annex A of IS 16098 Part II 45 SEWAGE TREATMENT PLANT(STP) 46 Supplying, Design , Construction, Hydraulic testing , Commissioning and giving satisfactory trialsSTP of capacity 10KLD consisting of PMF Technology based along with the following accessories to the desired capacity of 10 KLD rated net outputcomplete as turnkey jobwith all involved electrical and mechanical componentsfor satisfactory performance of plant andrequired treated outlet waterparameters as per E-in-Cs Br Policy No 05/ 2023 dated 04 May 2023 complete all as specified and directed(a) Construction RCC tanks of following sizes:-(i) Septic tank of size - 3.70 Mtr x 1.80 Mtr x 1.50 Mtr - 01 No(ii) PMF tank of size - 4.20 Mtr x 2.80 Mtr X 1.20 Mtr- 01 No(iii) Filter Feed tank of size- 1.70 Mtr x 0.80 Mtr x 1.50 Mtr - 01 No(iv)Treated Water tank of size- 1.70 Mtr x 0.80 Mtr x 1.50 Mtr - 01 No(v)Chamber between PMF & FFT of size- 0.45 Mtr x 0.45 Mtr x 0.45 Mtr - 01 No(vi) Manhole Chanber made out of brick work im CM 1:6 suitable size with FRP Manhole Covers of size - (600 mm x 600 mm) - 05 Nos 47 (b) Supply & laying of Stone course aggregate of following sizes:-(i) 8 size (200 mm) - 2.60 Cu mtr(ii)4 size (100 mm)- 2.60 Cu mtr(iii)2 size (50 mm) -2.60 Cu mtr(iv)Coarse Sand - 2.60 Cu mtr(c) Supply & laying of Bacterial Culture ( suitable for degrading sewage-1200.00 KG(d) Supply & plantingof saplings Canna Indica - 60 Nos(e) S & F for Non-clog submersible Raw sewege Pump, Single phase, 230 Volts, 50 Hz of discharge capacity 0.63 cum/ Hr @ 10 Mtr head complete- 02 Nos (01 W+ 01 S) (f) S & F for Submersible opern well pump set, Single phase, 230 Volts, 50 Hz for fresh treated water application discharge capacity 0.63 cum/ Hr@ 25 mtr head complete- 02 Nos (01 W+ 01 S) (g) Supply and install for heavy duty chemical dosing system plunger type suitable to injet solution with suitable capacity, working pressure10 Kg/cm2, comprising dosing pump coupled with 3 phase electric motor of suitable capacity, 1440 rpm assembly with Agitator in one motor , Agitator with stainless steel sweepblade duly FRP coated, FRP tank suitable capacity, complete unit mounted on heavy duty MS fabricated frame duly anti corrosive paint complete with chemical grade PVC NRV along with control panel for dosing pump suitable made of power coated MS fabricated box consting of LED indicater, digital Voltmeter, single phase preventor, high voltage, low voltage protection complete - 01 Job 48 (h) S & F for of PSF (Pressure sand filter) of size 250 mmin dia and height 1.30 mtr made out of FRP material suitable for withstand of 2.50 kg/cm2 pressure with multi port valve and interlinking piping - 1 Job(j) S & F for for ACF (Activated Carbon Filter) ofsize 250 mmin dia and height 1.30 mtr made out of FRP material suitable for withstand of 2.50 kg/cm2 pressure with with multi port valve and interlinking piping - 01 Job(k) S & F for UPVC Pipe of sizes 25 mm dia & 40 mm dia suitable with stand the pressure 6 kg/cm2 as required- 01 Job(l) S & F for copper conductor multistranded 3 core cable PVC insulated sheathed calble of size 2.5 Sqmm for motor connections from starter panel to motor control connector as required- 01 JobNote:-Components/ units/ Equipment/ accessory for PMF Technology based STP is as perdesign and indicative . However OEM can add/ alter/ omit the given components as per their design to achieve desired capacity and treated outlet water parameter with same technology as per E - in- Cs Branch New Dehli guidelines/ policies . 49 Supplying, Design, Construction, Hydraulic testing , Commissioning and giving satisfactory trials for Chop Whoop Winding Process MBBR/ JOHKASOU based FRP Underground Package STP along with the following accessories to the desired capacity of 30 KLD rated net output, complete as turnkey job with all involved electrical and mechanical components complete all as specified and directed for satisfactory performance of plant and required treated outlet water parametersas per E-in-Cs Br Policy No 05/ 2023 dated 04 May 2023Note:- The STP shall be designed based on the inlet & outlet parameters of E-in-Cs Branch above policy.(a)Chop Whoop Winding Process MBBR/ JOHKASOU based FRP Underground Package STP inclusive of Solid Separation, Anoxic Zone, MBBR Aeration Zone & Final Sedimentation zone Tank of size 8440 mm (L) x 2430 mm (dia) Tank- 01 No(b)Chop Whoop Winding Process based FRP Underground Intermediate Water Storage Tank 10 KL of size 4310 mm (L) X 1830 mm (dia) Tank- 02 Nos(c) With socket provision on tanks as per the design of UPVC return sludge pipe 50mm dia, PVC inlet outlet pipe 150mm dia, PVC interconnection pipe of 150mm dia, UPVC 80 mm dia, FRP Straps, Turn Buckle Wire Rope, Concrete Deadman & Eye Bolts per the diameter & length of the tank, Manhole cover as per the drawing, PVC air vent nozzle of dia 50mm, manhole cover of size 550mm dia, etc- 01 Job.(d) S & F for On-Ground LLDPE Treated Water Storage Tank of 10 KL Capacity of size2550 mm dia x 2510 Height- 01 No(e)Supply installation, testing and commissioning of cubical type Relay Based Control Panel out door type madeout of 3.15 mm thick CRCA sheetof suitable size suitable for 415V, 3 Phase, 4 wire, 50 Hz AC with necessary MCCB for incoming , copper busbar, MCB for out going & necessary DOL stater etc- 01 Job 50 (f)Twin lobe rotary Air compressor capable of delivery 56 Cum /Hr suitable volume of free air at 0.27 - 0.37 kg/sq.cm, discharge Pressure 0.2 - 0.3 kg/cm2g, Noise Level at 1.5 m distance: <70-80 (DBA),Body rotter made out of EN19 with FG260 & FG-260(CI), Silencer Fabricated with MS material.driven through V belt or directly coupled though flexible coupling to a TEFC motor of suitable capacity 1440 RPM, 415 Volts, 3 Phase,50 Hz, Pressure guages-01 No,150 mm NRV -01 No, Butterfly shut off valve, air filter, cleaner etc including 3 core copper cable multistranded connection of suitable size from starter to air compressor assembly complete all as specified and directed. 02 Nos (1W + 1S)(i)UPVC pipes 80 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing works complete all as specified- 01 Job(g) Sludge Recycling Pumpof non clog submersible sewage pump set suitable to handle domestic sewage water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set suitable with Flow Rate 9.0 m3/hr, Head 10 Mtr (1.0 HP) for operation at 415Volts frequency 50Hz, 3 Phase- 01 No (1W) (For Sludge recycling in Solid Separation zone)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor type shall be a squirrel cage induction motor with F class insulation. (ii)UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrangements complete all as specified- 01 Job(h) Pressure Sand Filter Capacity 3.0 cum/hr made out ofFRPSide Mounted of Size: 21 x 62,workingPressure 10 PSI, Filter Media, Pebbles & Filtering Sand, PVC Piping 50 mm Size (UPVC), Multiport Valve (Manual)-01 Job 51 (j)Activated Carbon Filter Capacity: 3.0 cum/hr, made out ofFRPSide Mounted of Size: 21 x 62, workingPressure 10 PSI, Filter Media: Activated Carbon 900 - 1100I/V,PVC Piping 50 mm Size (UPVC), Multiport Valve (Manual)-01 Job(k)Chlorine (Sodium Hypochlorite) Dosing Pump of Capacity 0-6 LPH, PTFE Diaphragm, single phase 230 Volts, 50 Hz including with HDPE Chlorine Dosing Drum of Capacity 100 Ltrs and necessary connections etc- 01 Job(l) Filter feed pump of non clog submersible sewage pump set suitable to handle domestic sewage water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set with Flow Rate 3.0 m3/hr, Head 15-20Mtr (1.0 HP), suitable for operation at 415 Volts, 50Hz , 3 Phase- 02 Nos (1W+1S) (For pumping into PSF & ACF Filters)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor type shall be a squirrel cage induction motor with F class insulation. (ii) UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrangementscomplete all as specified- 01 Job(m)Raw sewage Water transfer Pump of non clog submersible sewage pump set suitable to handle domestic sewage water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set with Flow Rate 9.0 m3/hr, Head 10-15 Mtr (1.0 HP) suitable for operation at 415 Volts, 50Hz , 3 Phase- 02 Nos (1W+1S) (For pumping from Raw Sewage Collection tank into the Bar Screen Chamber)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor (k) Ctype shall be a squirrel cage induction motor with F class insulation. (ii)UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrandements complete all as specified- 01 Job 52 (n) Treated Water transfer Pump of Monoblock pump set suitable to handle domestic treated water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set with Flow Rate 9.0 m3/hr, Head 10-15 Mtr (1.0 HP) suitable for operation at 415 Volts, 50Hz , 3 Phase (1W+1S) (For pumping from treated water zone to reuse)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor type shall be a squirrel cage induction motor with F class insulation. (ii)UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrandements complete all as specified- 01 Job(o) Fine bar Screen with chamber (manual) of SS 304 for screening 5 to 6 mm particles of size 1.0 Mtr x 1.0 Mtr at inlet of MBBR tank- 01 Job 53 Note : - (i)The Package STP tank shall be made from 100% FRP Material through Chop Whoop Winding Process with compliance and certification/approval in UL 1316 from the UL LLC that is Underwriters Laboratories LLC.(ii)The FRP tanks shall be made using Isopthalic Unsaturated Polyester Resin.(iii) The Sewage Treatment Plant system shall have a valid certificate of a Green product from a reputed Government or Third party having authority to certify like CII, IGBC, Assocham or any other body having competence in issuing such certificates.(iv)The shell thickness of the tank shall be between 6.50 mm to 7.50 mm (±0.5 mm) & Dish end thickness must be 11 mm and above made only from 100% FRP material(v)Technology must be empanelled in CPHEEO Sewage Manual.(vi)Minimum Hydraulic Retention time of the total Package STP system/tank must be 22.00 hours.(vii)Minimum sludge handling should only be once a year(viii)STP must function from minimum load of 5 - 10% to 100%. (Minimum load to Peak Load)(ix)The STP must have an anoxic zone for denitrifuication(x)Minimum volume of Intermediate Water Storage tank in FRP MOC must be 10 KL(xi)Minimum volume of Treated Water Storage tank in LLDPE MOC must be 10 KL 54 Material and Labour for Motor ControlLT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. Motor Control LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) complete including the following accessories:-. 55 IN COMING:-(i)Copper strip busbar of 60 Amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos(ii) On load change over Switch TPN of capacity 32Amps - 01 No (iii) 4 Pole MCB of capacity 5-32 Amps 10 KA breaking capacity C curve-01 No(iv)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three) (v)Digital Multifunctional meter , flush mounting type with CT’sand selector switch – 01 set.OUT GOING :-(b) MCB SPN 5-32 Amps 10 KA breaking capacity C curve-04 Nos(c) DOL starter single phase with suitable relay range conforming to IS -1347(Part IV) suitable for discharge capacity 6.4 LPM ( 0.38 Cumt/Hr)at 10/25 Mtr head, 0.50 HP, including overload relay, auto timer, indicating lamps (LED) etc complete -04 Nos 56 Supply and laying fordouble wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 (Part I and II) for protection of underground cables of size nominal outer dia 63 mm & nominal inner dia 50 mm dia with all fittings laid in trenches / road/ nallah or fixed along wall for cable protection all as specified. 57 HOT WATER SUPPLY 58 Supply and installation,commissioning and testing at roof top of building Solar water heating system (Flate Plate Collector) based on indirect transfer of heat of capacity 100Ltr per day with electrical back up of 2 KWas per manufacturers recommednations includinghot water storage tank of capacity 300 ltrs and of 20 guage thickness stainless steel plate (having insulation of rock wool ) mineral wool 100 mm thick & cladding with aluminium sheet 24 SWG complete all as specified and directed. 59 ROAD/ PATH 60 Material and labour for providing and painting 2.5 mm thick road marking strip (retro reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser,propane tank heater and profile shoe heater, driven by experienced operator on road surace including all cost of material, labour, T&P, cleaning of road surface of dirt, seals, ils, grease and foreign material etc. complete all as specified and directed. 61 EXTERNAL ELECTRIFICATION 62 Supply and fixingfor Cable route indicator / Marker made up of PCC Block in cement mortar 1:3:6 ( 20 mm graded aggregrate ) of size 900 x 300x 100 mm thick with DANGER/ 11 KV CABLE/ MES embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work ( as required / ordered at site) complete all as specified and as directed. 63 S upply and fixingfor Cable route indicator / Marker made up of PCC Block in cement mortar 1:3:6 (20 mm graded aggregrate) of size 900 x 300x 100 mm thick with DANGER/ LT 433 VOLTS CABLE/ MES embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work (as required/ ordered at site) complete all as specified and as directed. 64 Supply, installation, Testing and commissioning of Outdoor type (IP 54), 03 way RMU (Ring Main Unit) 11 KV, 630 Amps, 21kA-3 Sec,IP54 SF6 insulated, One side Extensible,consisting of One No (01) motorised vacuum circuit breaker (Incomer) and Twor Nos (02) motorised vacuum circuit breaker (Outgoing) & Metering Panel Bus PT with Top LV, Battery & Battery charger, Ethernet switch & LIU (Configuration VVV+M), inside robotically welded stainless steel 304 (Non Ferrite non Magnetic Grade) tank having min thickness 2.5 +/- 0.5mm with IP 67 degree of protection and enhanced BIL of 75 kVp internally to manager voltage surges and Air Insulated Metering Module of Class-0.5. RMU should be provided with internal busbars, as well as earthing busbars of electrolytic grade copper, padlock provisions & complete with all accessories. The complete RMU must be type tested for Internal arc21KA for 1 sec with AFLR Classification for Gas tank & Cable Chamber as per IEC 62271-200. HT RMU shall preferably have on-site-repairability features such as site replaceable bushing/ coupling/ mechanism and gas refilling to have very less downtime in the event of bushing breakage and restoration can be done at site immediately without sending the RMU to OEM Works, the Vaccum Interrupter must RMU manufacturers own make. The earthing busbar shall be provided inside each cable compartment for solid earthing of cable shields. The outer hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protectioncomplete all as specified and as directed. The unit shall include the following with all necessary standard fitting as required at site.-Make of RMU shall be limited to : ABB/ SIEMENS/ SCHNEIDER INFRASTRUCTURE(Channel partner/ System Integrator/ Authourized Partner/ License partner make RMU shall not be accepted.) 65 (a) Vacuum Circuit Breaker consist of following accessories :-(i)Microprocessor based Numerical Protection Relay for Circuit Breakers - REF615, Feeder Protection and Control Relay, Protections 50, 51, 50N, 51N, 46, 49, 67, 67N, 32, 27, 59, 25, 81U, 81O, 95 Measurement for 3I,I0,3U,U0,Kw,KVA,PF,Hz,Kwh, 16 DI + 10 DO, One front RJ45 Port, One Rear RJ45 Port for IEC-61850 Protocol, Drawout Type with CT Shorting feature, Graphical LCD Display(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator on the gas tank.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO amd suitable for 10,000 mechanical operation.(v)CT shall be minimum 50-100/1A ,2.5VA , 5P10 - 3 Nos. for protection(vi)CT shall be minimum 50-100/1A ,2.5VA , Class 0.5 - 3 Nos. for metering(vii)Right angle boot to be provided in each module(viii)2 x12 Volts, 26 AH Battary with Charger - 1 Set(ix)Bus VT shall be 11KV/V3/110V/V3 ,20VA , Class 0.5 - 3 Nos. for metering(x)Auxiliary VT shall be 11KV/230 ,500VA for AC supply input to Battary Charger.(xi)Capacitive voltage indication fixed type system as per IE(xii)Interlocked Cable box for front termination of the cable suitable upto 3 core 120 Sqmm,11 KV XLPE cable (IP3X). Safety interlocked to prevent access to cable termination in live-condition. 66 (xiii)Right angle boots (push on type)(xiv)Cable covers with self Interlocking mechanism between doors, earth switch, disconnector & VCB.(xv)Necessay interclocking arrangement for safety and operations(xvi)One No. Operationg Handle for Manual Operation and one no. manometer(xvii)Safety Interlocks Shall be provided as per relevant IEC/IS Standards and Manufacturers directions.(xviii)Above switchgear shall confirm to all relevant IEC/IS Standards. 67 Supply, installation, commissioning and testing of transformer of capacity 315 KVA, confirming to IS 1180 (Part-1)- 2014 with latest amendment No 4, BEE 3 star rated, EEL 3, step down Outdoor type complete with standard fittings, HT 11 KV 3 phase LT 433 vols, 3 phase, 4 wire corrugated 7 position off circuit tape links of rating + 7.5 to -7.5% @ 2.5% by means of hand operated off load tap changer including necessary control wiringtransformer copper wound, double wound, oil immersed naturally cooled with external cooling tubes core type delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector symbol Dyn -11 (vector group with neutral brought on secondary side (LV side) and the maximum temperature rises should not exceed 40 degree centigrade in oil and 45 degree centigrade in HV/LV winding ring measured by resistance after continuous full load run in ambient temp as per IS -2026 per transformer, IS-3639 for fitting & accessories, IS-2099 for high voltage porcelain bushings and the transformer shall be comprised with the following standard fitting with on load tappings on HT side to vary secondary voltage within limit all as per IS -1180 complete all as specified and as directed wit latest policy for following:- 68 Note 01:- (i)Three Nos porcelain bushing suitable for 11 KV on HV side, complete with copper rods, nuts and washers with cable end box.(ii)Four Nos porcelain bushing suitable for 433V on LV side, complete with copper rods, nuts and washers with cable end box.(iii)Monogram plate.(iv)Oil conservator with filter and drain plug.(v)Prismatic/transparent oil gauge.(vi)De-hydrating breather with first fill of dehydrating agent (silica gel).(vii)Thermometer pocket.(viii)Air release plug.(ix) Inspection cover(x) Lifting lugs for complete transformer(xi)Top cover lifting lugs(xii) Jacking lugs(xiii) Top filter valve(xiv)Instruction plate(xv)Drain cum bottom filter valves(xvi)Earthing terminal and stud(xvii)Off load tap changer (xviii)Rating and Diagram plate(xix) Buchholz relay with alarm & trip contacts.(xx)Bi directional roller wheel -04 Nos. 69 (xxi)Marshalling box for termination of all alarm & trip controls of the transformer.(xxii)WTI (Winding temperature indicator) with alarm & trip contact(xxiii)Oil surge relay.(xxiv)Shut off valve for buchholz relay.(xxv) OTI (Oil temperature indicator) dial type of 150 mm with alarm and trip contact capillary type.(xxvi)Two earthing terminals on tank cover to facilitate fixing of 50x6 mm galvanised iron earth strip for earthing of body.(xxvii) Necessary PCC foundation/ block masonry platform as directed by OEM. (xxviii)First filling of new and unused transformer oil, IS-335 marked.Note 02 :- (a)The rates include for supplying transformers with standard fittings and installing complete including all jointing materials, connecting with electrical system, earthing, testing and commissioning. (b) The transformer will have its initial oil filling to appropriate level (cost of oil including testing with desired dielectric strength included in supplied and installed rates, cost of PCC foundation shall be included as per manufacturer drawing) 70 Supply, fixing, installing and commissioning of octagonal Galvanised street light pole 9 mtr long, top dia 70 mm, bottom dia 155 mm, sheet thickness 3 mm and base plate dimensions 260 x 260 x16 mm thickness with door locking arrangement for provision ofterminal plate consisting ofMCB TPN 10 Amps, with necessary electrical connections including 04 Nos foundation with J type foundation bolts -04 Nos of sizeas per manufacturer design should be hot dipped galvanized andGI single arm bracket (Ornamental type) complete with door locking arrangement complete all as specified and directed.Note:- Necessary Excavation of Soil, RCC foundation as per manufacture recommendation including foundation bolts etc deemed to be included in quoted rate. 71 Supply ,fabrication, installation and testing of LT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) .All extension link/ inter connection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:- (Transformer main LT Panel) 72 Note:- Rate of earthwork and PCC work etc are deemed to be inclusive in this item.IN COMING:a)Copper strip busbar of 1000 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nosb)4 pole MCCB 500 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.(c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider.(d)Digital Ammeter of range (0- 250) Amps, flush mounting type with CT’s of ratio 250/5 and selector switch – 01 set.(e)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. 73 OUTGOING:- (a)4 Pole MCCB 125 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No (MWO/ WO accn Bldg Panel No 1)(b)4 Pole MCCB 160 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 04 Nos (for Sgt Accn Panel No 2, 3, APFC panel & Spare)(c)4 Pole MCCB 32 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No(d)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter - 01 No. 74 Supply ,fabrication, installation and testing of LT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) .All extension link/ inter connection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:- (forMWO/WO Accn LT Bldg Panel No1)Note:- Rate of earthwork and PCC work etc are deemed to be inclusive in this item. 75 IN COMING:-a)Copper strip busbar of 250 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nosb)4 pole MCCB 125 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.(c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider.(d)Digital Ammeter of range (0- 250) Amps, flush mounting type with CT’s of ratio 250/5 and selector switch – 01 set.(e)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. 76 OUTGOING:- (a)4 Pole MCCB 63 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 03 Nos (forMWO accn Bldg supply- 2 Nos & Spare)(b)4 Pole MCCB 32 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 01 No (Street light)(c) Multifunctional Digial type Astronomical function Time switch (Astro type having longitude and latitude of Indian cities memory) 240 volts AC Single Phase - 01 No(d) Power contractor 4 Pole, 32 Amps,415 Volts, 50 Hz - 01 No (e)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter - 01 No. 77 Supply ,fabrication, installation and testing of LT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) .All extension link/ inter connection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:-(for Sgt accn Bldg Panel No 2 & 3) 78 Note:- Rate of earthwork and PCC work etc are deemed to be inclusive in this item.IN COMING:- a)Copper strip busbar of 400 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nosb)4 pole MCCB 160 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.(c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider.(d)Digital Ammeter of range (0- 250) Amps, flush mounting type with CT’s of ratio 250/5 and selector switch – 01 set.(e)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. 79 OUTGOING:- (a)4 Pole MCCB 100 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 03 Nos ( Sgt Accn bldg supply- 02 Nos & Spare)(b)4 Pole MCCB 32 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 01 No(e)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter - 01 No. 80 Material and labourfor Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure for cable protection and making good as existing complete all as specified and as directed. 81 Material and labourfor maintenance free Chemical earthing of technology 3 mtr long20 mm dia with 250-micron Copper coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 holes of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material- polymer body & cover dimensions- 308 mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed. 82 Note:- (i) Earthing is to be done infront of the Engr-in-Charge.(ii)Test Results of earthing to be submitted by the contractor for all earthings.(iii)The Contractor shall have to give written guarantee for maintenance earth resistance of less than 1.0 Ohm for the period of 10 9ten) years after certified date of completion and shall bdeposited 2000/- per earthing as security deposit for a period of Ten (10) Years.(iv)Failing to maintain resistance of earthing less than 1.0 ohm , new earthing to be provided by the contractor with out any extra cost.(v)Necessary earth work, excavation shall be carried out in any type of soil strata, retuning, filling in and making good surronding area complete. 83 EXTERNAL WATER SUPPLY 84 Supply, Laying, jointing & testing of 150mm dia (6) Ductile iron (DI), pressure pipes with spigot and socket ends, centrifugally cast, class K-7, with cement mortar lining in inner side as per IS:8329/ 2000 (latest revision) and other relevant standards and metallic zinc coating followed by a finishing layer ofepoxy paint in outer side,suitable for push on joint(rubber gasket joint) including rubber gasket in any length with inside cement mortar lining laid in trenches/ over masonry pillarcomplete all as specified and as directed 85 Supply, Laying, jointing & testing of 100mm dia (4) Ductile iron (DI), pressure pipes with spigot and socket ends, centrifugally cast, class K-7, with cement mortar lining in inner side as per IS:8329/ 2000 (latest revision) and other relevant standards and metallic zinc coating followed by a finishing layer ofepoxy paint in outer side,suitable for push on joint(rubber gasket joint) including rubber gasket in any length with inside cement mortar lining laid in trenches/ over masonry pillarcomplete all as specified and as directed.Notes foraboveItems No 53 & 54 :- (i) Excavation & Earthwork, shall be measured and paid separately. (ii) The necessary Exise duty exemption certificate from Deputy Commissioner of respective district shall be arranged by the GE for DI pipe.The contractor shall quote the rates against these items considering Exise exemption. (iii) The quoted rate shall also be deemed to include for provision of joints and jointing material for laying pipes. For jointing ofpipe fittings or taking branch connection, provision of joints and jointing material shall be measured and paid separately. (iv) . Before laying of pipe line contractor has to submit layout diagram as per level difference and ensure proper alignment of the pipe. 86 Material and Labour for Ductile iron fitting for spigot socket pipe such as bends (any type, radius and angle) tapers any type (straight, bend increasing, decreasing or double socket etc). Tee pieces single branch. Y junction, double branch, cross (All socket or socket and spigot) collars, restrained joint, mechanical joint, caps & plugs 80 mm to 250 mm dia bore including cutting and jointing new positions complete all as specified and as directed 87 Material and Labour forcutting CI pipes 150 / 80mm in position for insertion and including provision of Tee branches etcfor 80/50 mm dia pipe line complete all as specified and directed 88 Material and labour for construction of brick masonry valve pit of internal size 90cm x 90cm x 90cm suitable for gate valves/ sluice valve upto 150 mm including necessary excavation and earth work, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 50mmx50mmx6mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock complete all as specified and directed.Note:- (i) Brick wall shall be 23 cm thick built in cement mortar (1:6)(ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450 mm from top shall be 20 mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds(iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls (iv) PCC coping shall be 15 cm thick in cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC(v) Three coats of white wash to internal surfaces of valve pit shall be provided(vi) Depth of valve pit shall be reckoned from the top of PCC in foundation 89 Material and labour for construction of brick masonry valve pit of internal size 60cm x 60cm x 70cm suitable for gate valves/ sluice valve upto 150 mm including necessary excavation and earth work, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock complete all as specified and directed.Note:- (i) Brick wall shall be 23 cm thick built in cement mortar (1:6)(ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450 mm from top shall be 20 mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds(iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls (iv) PCC coping shall be 15 cm thick in cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC(v) Three coats of white wash to internal surfaces of valve pit shall be provided(vi) Depth of valve pit shall be reckoned from the top of PCC in foundation 90 RAIN WATER HARVESTING 91 Supply and Fixing 150mm bore PVC slotted pipes double socketed in any length with suitable joints, laid in bore hole for recharge pit and like complete all as specified and directed 92 Boring 300mm dia for Bored cast in situ piles 16 metres in any kind of soil/soft rock and getting out and disposal of spoil to a distance 50 metres using suitable method complete all as specified and directed 93 FIRE FIGHTING SYSTEM 94 Supply and Fixing for 3 kg light-weight squeeze grip CO2 type fire extinguisher, conforming to IS 15683: 2006, with CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed Make: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 95 Supply and Fixing for 5 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directedMake: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 96 Supply and Fixing for 9 litre mechanical foam type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted with gunmetal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directedMake: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 97 Supply and Fixing for 9 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directedMake: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 98 Supply and Fixing for Galvanized mild steel Fire bucket (Filled with dry sand & water) conforming to IS 2546: 1974 round bottom type enamel painted, white inside & Red out side and Letter FIRE in black out side and handle with mounting bracket complete as specified and directed 99 Supply and Fixing for Galvanized mild steel Fire hook bracket with 3 mtr bamboo handle painted with red colourcomplete as specified and directed 100 Supply and Fixing for Galvanized mild steel Fire Beater bracket with 3 mtr bamboo handle painted with red colourcomplete as specified and directed
Contract Date: Mar 11, 2026 Contract Value : 14.98 Crore
Statutory Bodies & Commissions/Committees No of Bidders 5
49.
Defence #9749490 AOC
Tender For Provision Of Klp Accommodation (Ph-I) At Jp Line Alwar; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 2 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 3 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 4 Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND HARDSTANDINGas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 5 Lump sum price worked out by the contractor for SEWAGE DISPOSALas listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 6 Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 7 Lump sum price worked out by the contractor for FENCING , GATE AND COMPOUND WALLas listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 8 Lump sum price worked out by the contractor for RAIN WATER HARVESTING as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 9 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 10 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 11 Lump sum price worked out by the contractor for LIGHTING PROTECTIONas listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 12 Lump sum price worked out by the contractor for SUMMER APPLIANCES AND AIR CONDITIONING as listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 13 Lump sum price worked out by the contractor for DG SET as listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 14 Lump sum price worked out by the contractor for CRANE as listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 15 Lump sum price worked out by the contractor for SITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORKas listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 16 Lump sum price worked out by the contractor for DEMOLITION AND DISMANTLINGas listed in Schedule ‘A’ Part-XVI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 17 Sch A Part-XVII MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes:(i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XV (SITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORK schedule). 18 INTERNAL WATER SUPPLYS&F for 15mm bore two way bib cock double handle with flange fancy type, cast copper alloy, chromium plated screwed down high pressure with crutch or butterfly handle,screwed both ends for iron pipe of for union etc complete all as specified and directed 19 S&F for 15mm bore dia flush cock ofcast copper alloy,screwed for iron pipe fixed etc complete all as specified and directed 20 INTERNAL ELECTRIFICATIONS & F for lamp holder including Highly efficient LED Bulbs, 9 wattinsulated body with back plate suitable for batten fittings etc complete all as specified and directed. 21 S&F for modulartype 1 module RJ-11 telephone socket with shutter etc complete all as specified and directed 22 S&F ofmodular blanking plates 1 Module complete all as specified and directed 23 S&F of Sheet metal enclosure distribution board VTPN4 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 24 Supply and fixing SP 63Amps rating 240V, 10KA B curve rupturing capacity, IS-8828marked fixing in DBs complete all as specified and directed.Note : (a) Make of the MCB should be the same as that of DB.(b) DBs shall be catered respective items of this schedule 25 M&L for concealed flame proof point wiring (using red, black and green colour wires as colour coding for single phase circuit) for one light point complete with 1.50 Sqmm (nominal cross sectional area) FRLSH PVC insulated unsheathed and multisranded copper conductor cable 1100 V (ISI marked) for main point and for continues as earth wire connected to earth dolly etc (Phase, neutral and earth wire) drawn thorugh and including ERW steel rigid heavy duty socket, elbow, connector, reducer, pipe hook etc for light/fan points including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc by using CM (1:3) etccomplete all as specified and directed.Note :- (i) Two nos of light point circuits shall be controlled by one rotaty switch/MCB fixed in existing DB. (ii) Rotary Switches, junction box, MCB shall be measured and paid separately under appropriate item of this Sch. 26 Supply and fixing (Concealed in wall) factory made flameproof DB duly painted, 4 way dust and vermin proof including with all accessories complete all as specifed and directed.(i) MCBB Curve SPN 32 Amps, 10KA- 01 No (incoming)(ii) MCBB Curve SP 6 Amps, 10KA- 02 Nos (outgoing) 27 SEWAGE DISPOSALM&L for DWCPE pipe laid to slope in trenches,jointed and tested complete with collar for 180mm(outer dia)/163mm (inner dia) bore pipe etc complete all as specified and directed. 28 S&F for 75mmthick steel fibre reinforced concrete (SFRC) cover and frame ( Medium grade )confirming to IS-12592, minimum load bearing capacity 5 tonne/Sqm, in square ,rectangular or circular shapeetc complete all as specified and directed.Note:Qty 150 Sqm of 75mmthick steel fibre reinforced concrete (SFRC) will be executed againt Srl item 28.00 of Area Drainage 29 AREA DRAINAGES&F for 75mmthick steel fibre reinforced concrete (SFRC) cover and frame ( Medium grade )confirming to IS-12592, minimum load bearing capacity 5 tonne/Sqm, in square ,rectangular or circular shapeetc complete all as specified and directed.(Qty 150 Sqm). Note:75mmthick steel fibre reinforced concrete (SFRC)will be mesured and paid underSrl item 27.00 here in before. 30 FENCING , GATE AND COMPOUND WALLM&L for steel gate 5.45m wide and 3.50m height with RCC pillar incl excavation in any type of soil, plastering, painting etc complete all as specified and shown in TD /2004/13 sh 1/3 to 3/3 CE Jaipur Zone 31 EXTERNAL WATER SUPPLY Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-7 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 32 M&L construction of brick masonryvlave pit / chamber of size 1050 mmX 750mm X 1000mm(type D) (internal dimensions of chamber)depth to be reckoned from the top ofPCC in foundation to top of MS cover with MS sheet cover 3mm thick including frame of angle iron 40 X 40 X 6 mm with locking arrangement and lifting handle including painting two coats of black synthetic enamel paint over a coat of red oxide primer etc including brick work in one brick thick wall in cement mortar 1:4, 15mm thick plastering in cement mortar 1:4 (internally on all brick wall and external upto 15cm below ground level) and necessary excavation and earth work in any type of soil, returning, filling in, disposal of surplus spoil to a distance not exceeding 50 mtr 15 cm thick PCC 1:4:8 type D-2 in PCCfoundation projected by 15cm all round from the outer face of brick wall PCC 1:2:4 type B-1 in coping etc complete all as specified and shown in TD /2004/26 sh 1/3 to 3/3 CE Jaipur Zone 33 Supply, installation, testing and commissioning of Submersible pump, electric driven 415 V, TP suitable for 200/250 mm dia bore well ( Casing pipe size 200/250 mm) supply and Install complete upto 15WHP inclusive of 40 metre long submersible cable and starter. complete all as specified and directed. Material of Construction: Impeller:Stainless steel , Diffusor: Stainless steel , Diffusor casing: Stainless steel,Shaft; Stainless steel ,Bearing Sleeve : High Crome Stainless steel all as specified and directed. 34 Trial bore of 250 mm dia upto 200meter depth below ground level in any kind of soil strata including hard stone/boulder etc. including submitting the strata details both graphically recorded as well as strata results etc complete all as specified anddirected.Note :-The rates quoted shall deemed to include to get survey done for availability/facibility of water as recommended by GWD before execution of work. 35 Trial bore of 250 mm dia exceeding 200meter depth below ground level and upto 400 RM in any kind of soil strata including hard stone/boulder etc.including submitting the strata details both graphically recorded as well as strata results etc complete all as specified anddirected.Note :-The rates quoted shall deemed to include to get survey done for availability/facibility of water as recommended by GWD before execution of work. 36 Development of trial bore Reaming up to by reaming in following step:- (a) From 250mm to 350 mm(b) From 350mm to 450 mm from depth exceeding to 200 meter to 300 meter including casing pipe of 250mm dia and thickness 8mm and pea gravel. etc complete all as specified and directed. 37 Supply, assembling, including jointing lowering and fixing in position ERWMS slotted pipe 250mm dia of 5.4mm thickness ( minimum ) having slots of 1.59 mm wide, 75 mm long assembled and lowered as per location chart approved by the GE including cutting welding as required and painting etc complete all as specified anddirected.NOTE:- Rate quoted by contractor shall deemed to include for S&F well cap 250 mm dia on top of pipe with locking arrengement till the bore well become functional complete. 38 Development of tube well by compressed air with compressor of minimum capacity of 150 PSI and 450 CFM etc complete all as specified and directed dy Engineer- in - Charge.NOTE:-(i) Yield test for the bore well by continuously pumpingto determine safe pumping yield to be carried out by contractor at site and necessary report to be submitted.(ii) Testing of water for potability, dissolved solids, physical/chemical and bactorogical testing etc from the govt lab shall be carried out by the contractor all as directed and test report shall be submitted.(iii) The rates quoted shall deemed to include the above provisions. 39 S&F for MS reducer, bail plug, well cap, MS strip for centering, MS iron clamps, electric logging and sample strata box. etc complete all as specified anddirected. 40 S&F of openwell submersible booster pump of capacity 10 HP having min Head of 20-42M, size of delivery 80x65mm, 1650-700 LPM,etc complete all as specified anddirected. 41 Supply, install, testing & commissioning of LT panel outdoor type (KIOSK) factory made powder coated paint made of 3.15 mm thick CRCAsheet, CPRI approved, dust and vermin proof protection, with 200 Amps copper bus bars front opened with locking arrangements mounted on angle iron frame 40x40x6mm, 45cm height from ground level with PCC foundatioin in 1:4:8 type D-2 complete, comparising of the following accessories :- (a) MCCB 63 Amp 16 KA rating 4 pole 440 volts-01 No (b) MCB-63 Amps, TPN 440 V, 10 KA-01 No (c)Starter, star delta, fully automatic suitable for 15 HP 3 phase elect motor - 01 No (d)Digital Amp/Volt/PF meter with selector switch & CT0-50 Amps - 01 No (e) Single phase preventor mini lec VSP-II-01 No (f) Phase sequance corrector 15 HP motor, 3 phase-01 No (g)LED Indicator lamp - 03 Nos (RYB)(h) Wiring with suitable size copper conductor cable for LT panel.(j) Power factor correction capictor bottle type, 5 KVAR 3 phase- 01 No 42 S&F 1100 Volts grade submersible cable flate 3 core with copper conductor 10 sqmm stranded fixed to column pipes with suitable clamps jointing material etc complete all as specified and directed dy Engineer- in - Charge. 43 EXTERNAL ELECTRIFICATIONDismantling and taking down old unserviceable HT/LT cable of any type/size etc complete all as specified and directed. 44 Dismantling and taking down old unserviceable LT Panel of any type/size etc complete all as specified and directed. 45 Dismantling and taking down old unserviceable bus bar chamber of any type/size etc complete all as specified and directed. 46 Dismantling and taking down old unserviceable submain wiring of any type/size etc complete all as specified and directed. 47 Dismantling and taking down old unserviceable earthing of any type/size etc complete all as specified and directed. 48 Supply, installing,testing and commissioning of 11 KV, 630 Amp Load break switch with 200 Amp DO set and earth switch etc complete all as specified and directed. 49 Supply and Installation of 11 KV Compact Sub Station with non extensible RMU consisting of 1 No manually operated 11 KV/630 Amps VCB in SF6 insulated stainless enclosure,HT Cable/Bus bar ,1 No transformer 500 KVA,11KV/433 CRT dry type & associated LT devices(ACB/MCCB/bus bar/Cable) having following specification:- 50 (a) HT Section:-11 KV, 630A SF6 RMU VCB (Non-Extensible, 1-way) with accessories:-(i)1 No. Direct Cable Module & 1 No. 630A Fixed Manual SF6 Circuit Breaker(ii) Self Powered Relay (IDMT)(iii) Ring Switches & T-Off SF6 Circuit Breaker with Earthing Switches(iv) Live Cable Indicator for Ring Switches(v) Padlocking Facility(vi) Shunt Trip Coil (230V AC) 51 (b)Transformer Section:-500 KVA, 11/0.433 KV, Copper Wound Dry Type Cast Resin Transformer:-(i)Off-Circuit Tap Links (5 positions, ±5% in 2.5% steps)(ii) Losses: 2800W @ 50% load, 7250W @ 100% load(iii) Digital WTI with alarm & trip contacts(iv) RTD Sensors 52 (c ) LT Section:-LT Panel comprising:(i) 1 No. 800A, 4 Pole, 25KA, 415V ACB (microprocessor-based with O/L, S/C, E/F protection)(ii) RYB Indication Lamps(iii) 800A/5A LTCT Cl:1.0(iii)Digital Ammeter & VoltmeterSwitchgear Meters 53 (d) Enclosure & Accessories:-MS Steel Sheet Enclosure (Outdoor Type) with Siemens Grey shade (RAL 7032):(i)Space Heater with ON/OFF Switch & Thermostat(ii)Single Phase Switch with Socket(iii)LT Cubicle Illumination Lamp with Door Limit Switch(iv)MCBs for AC/DC control(v)Bottom entry for incoming cables, outgoing via bus bars(vi)Aluminium Bus Bars & Earth Bus 54 Supply, installing,testing and commissioning factory made (incl CPRI type test certified), LT feeder pillar box (KIOSK), outdoor type plate form mounted suitable for 415 volts 3 phase and netural suitable for 4 wire 50 Hz AC supply system having bus bar chamber with insulated Copper bus bar 630 Amp rating not less than 60 cm long installed on porcelain insulators.The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder coated finish, frontand rear opening type with aprons for cable entry, with double door shutter and locking arrangement (including provn of 65 mm Godrej (Freedom) lock with 2 keys, internal wiring with suitable size of copper strip from bus bar to MCCB and metering wiring with PVC insulated, stranded copper conductor, FRLS Cable, IS-694 marked of adequate size but not less than 4 sqmm with 45cm height from ground level with PCC foundatioin in 1:4: 8 type D-2 complete the following accessories :-(Main Panel) 55 INCOMING:-(a) MCCB 630 Amp 50 KA rating 4 Pole 440 voltswith megnatic setting and thermal release- 01 No(b)Multifunction meter Class, 1.0, Three line Bakelite LCD Display with back sealing arrangement , with meter run hour & power on Hour, AVG , Max & total value of Active , reactive & apparent power & span shot of power ( KW) , current (I) , Voltage (V) & PF with programmable CT Ratio of -/5A along with Suitable size core CTs for current sensing (c)Indication lamp 22.5mm dia LED type 240 volts AC to show three phase availability-01Set.(d) Copper bus bar three phase630 Amp- Set of 4 Nos.OUTGOING(a) MCCB 250 Amps 35 KA rating 4 pole 440 volts megnatic setting and thermal release -03 Nos(b) MCCB 100 Amps 35 KA rating 4 pole 440 volts megnatic setting and thermal release -02 Nos(c) Astronomical timer 3 phase with MCB of capacity 6 to 32 Amp TPN- 01 no 56 Supply, installing,testing and commissioning factory made (incl CPRI type test certified), LT feeder pillar box (KIOSK), outdoor type plate form mounted suitable for 415 volts 3 phase and netural suitable for 4 wire 50 Hz AC supply system having bus bar chamber with insulated Copper bus bar 400 Amp rating not less than 60 cm long installed on porcelain insulators.The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder coated finish, frontand rear opening type with aprons for cable entry, with double door shutter and locking arrangement (including provn of 65 mm Godrej (Freedom) lock with 2 keys, internal wiring with suitable size of copper strip from bus bar to MCCB and metering wiring with PVC insulated, stranded copper conductor, FRLS Cable, IS-694 marked of adequate size but not less than 4 sqmm with 45cm height from ground level with PCC foundatioin in 1:4: 8 type D-2 complete the following accessories :-( Panel 1) 57 INCOMING:-(a) MCCB 250 Amp 25KA rating 4 Pole 440 voltswith megnatic setting and thermal release- 01 No(b)Multifunction meter Class, 1.0, Three line Bakelite LCD Display with back sealing arrangement , with meter run hour & power on Hour, AVG , Max & total value of Active , reactive & apparent power & span shot of power ( KW) , current (I) , Voltage (V) & PF with programmable CT Ratio of -/5A along with Suitable size core CTs for current sensing (c)Indication lamp 22.5mm dia LED type 240 volts AC to show three phase availability-01Set.(d) Copper bus bar three phase400 Amp- Set of 4 Nos.OUTGOING(a) MCCB 160Amps 18 KA rating 4 pole 440 volts fixed type -01 No(b) MCCB 100Amps 18 KA rating 4 pole 440 volts fixed type -01 No(c) MCCB 63Amps 18 KA rating 4 pole 440 volts fixed type -03 No 58 Supply, installing,testing and commissioning factory made (incl CPRI type test certified), LT feeder pillar box (KIOSK), outdoor type plate form mounted suitable for 415 volts 3 phase and netural suitable for 4 wire 50 Hz AC supply system having bus bar chamber with insulated Copper bus bar 400 Amp rating not less than 60 cm long installed on porcelain insulators.The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder coated finish, frontand rear opening type with aprons for cable entry, with double door shutter and locking arrangement (including provn of 65 mm Godrej (Freedom) lock with 2 keys, internal wiring with suitable size of copper strip from bus bar to MCCB and metering wiring with PVC insulated, stranded copper conductor, FRLS Cable, IS-694 marked of adequate size but not less than 4 sqmm with 45cm height from ground level with PCC foundatioin in 1:4: 8 type D-2 complete the following accessories :-( Panel 2) 59 INCOMING:-(a) MCCB 250 Amp 25KA rating 4 Pole 440 voltswith megnatic setting and thermal release- 01 No(b)Multifunction meter Class, 1.0, Three line Bakelite LCD Display with back sealing arrangement , with meter run hour & power on Hour, AVG , Max & total value of Active , reactive & apparent power & span shot of power ( KW) , current (I) , Voltage (V) & PF with programmable CT Ratio of -/5A along with Suitable size core CTs for current sensing (c)Indication lamp 22.5mm dia LED type 240 volts AC to show three phase availability-01Set.(d) Copper bus bar three phase400 Amp- Set of 4 Nos.OUTGOING(a) MCCB 160Amps 18 KA rating 4 pole 440 volts fixed type -01 No(b) MCCB 100Amps 18 KA rating 4 pole 440 volts fixed type -01 No(c) MCCB 63Amps 18 KA rating 4 pole 440 volts fixed type -02 No 60 Supply, installing,testing and commissioning factory made (incl CPRI type test certified), LT feeder pillar box (KIOSK), outdoor type plate form mounted suitable for 415 volts 3 phase and netural suitable for 4 wire 50 Hz AC supply system having bus bar chamber with insulated Copper bus bar 300 Amp rating not less than 60 cm long installed on porcelain insulators.The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder coated finish, frontand rear opening type with aprons for cable entry, with double door shutter and locking arrangement (including provn of 65 mm Godrej (Freedom) lock with 2 keys, internal wiring with suitable size of copper strip from bus bar to MCCB and metering wiring with PVC insulated, stranded copper conductor, FRLS Cable, IS-694 marked of adequate size but not less than 4 sqmm with 45cm height from ground level with PCC foundatioin in 1:4: 8 type D-2 complete the following accessories :-( LT Panel 3) 61 INCOMING:-(a) MCCB 250 Amp 25KA rating 4 Pole 440 voltswith megnatic setting and thermal release- 01 No(b)Multifunction meter Class, 1.0, Three line Bakelite LCD Display with back sealing arrangement , with meter run hour & power on Hour, AVG , Max & total value of Active , reactive & apparent power & span shot of power ( KW) , current (I) , Voltage (V) & PF with programmable CT Ratio of -/5A along with Suitable size core CTs for current sensing (c)Indication lamp 22.5mm dia LED type 240 volts AC to show three phase availability-01Set.(d) Copper bus bar three phase300 Amp- Set of 4 Nos.OUTGOING(a) MCCB 125Amps 18 KA rating 4 pole 440 volts fixed type -01 No(b) MCCB 63Amps 18 KA rating 4 pole 440 volts fixed type -03 Nos 62 Supply, install, testing & commissioning LT feeder pillar box (KIOSK) outdoor type, plateform mounted, compartmentalised and confirming to IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having busbar chamber with insulated copper busbars 100 Amps rating installed on porcelein insulators. The panel shall be dust and vermin proof, made of 3.15 mm CRCA MS sheet and with base frame of 40x40x5 mm angle iron, powder coated finish over two coat of red oxide primer, front and rear opening type with aprons for cable entry with double door shutter and locking arrangement including a lock with two keys, internal wiring with PVC insulated multi stranded copper conductor cable,FRLS cables ISI marked of adequate size but not less than 2.5 Sqmm. The scope of work also includes following alongwith PCC foundation complete all as specified and directed:-(Street Light Panel) 63 (a)Astronomical time switch - 01 No(b) 4 pole 32 Amp contactor- 01 No(c) 4 Pole 6 Amp MCCB-04 Nos.(d) Toggle Switch - 01 No(e) Glass Fuses(f) Neutral link(g) Push Buttons(h)LED indicating lamps (R, Y & B) -01 Set. 64 Supply,install,testing & commissioning automatic power factor correction (APFC) panel of 230 KVAR with metalised polypropylene capacitor bank MPP heavy duty of following capacity or nearest higher suitable to make step banking as per load requirement with minimum 12 steps intelligent relay controller having provision of multifunctional LCD display, set optimising control of capability with having facility of display system voltage, reactive power, active power apparent powerapparent current total harmonic display VTHD, ITHD plus individual harmonic display of voltage and current temperaturewith alarm out put including alarm system and front panel programming including connection with PVC copper conductor cable of suitable size housed in powder coated PBI sheet housing with hinged door dust proof and connecting with main etc. all as directed with following components (All components & capacitor bank shall be housed in enclosure factory made out of 16 SWG MS sheet outdoor in installation KIOSK type dust and vermin proof with suitable ventillating shutters (louvers) powder coated sheet metal feeder pillar box as per IS-5039 all as specified having locking arrangement , set of CTs Discharge reactors contactor heavy duty 4 pole 415 Volt with AC coil including MCBs indicating lamps and bypass system Alarm bell 240 volts 50 Hz -01 No. etc complete to achieve point 0.99/1.0 near to unity including necessary foundation pillar type copper bus bar of suitable size 3 phase system etc complete all as specified and directed. 65 Boring under roads/pavement/hardstanding without disturbing the top surface by trench less technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure forpassing through the cables complete all as specified and as directed. Note : Necessary infrastructure reqd for boring shall be arranged by the Contractor at his own cost. 66 Supply and erecting cable route marker for HT Cable made of precast RCC (1:2:4) using 20mm graded stone aggregate cast in pillar of size 20x15x75cm including reinforcement with 4 nos 10mm dia deframed bars of 55 cm length and link/stirupps of 8mm dia bras at 150mm C/C and in fixing in ground level duly pained &written HT 11 KV including PCC & earth work etc complete all as specified anddirected by Engr-in-charge. 67 Supply and erecting cable route marker for LT Cable made of precast RCC (1:2:4) using 20mm graded stone aggregate cast in pillar of size 15x10x60cm including reinforcement with 4 nos 10mm dia deframed bars of 55 cm length and link/strapps of 8mm dia bras at 150mm C/C and in fixing in ground level duly pained &written LT .433 KV including PCC & earth work etc complete all as specified anddirected by Engr-in-charge. 68 S&F copper service wire 1.5 sqmm 3 core PVC insulated and PVC round sheathed multistranded copper conductor flexible industrial cable 1100 V grade in street light poles complete all as specified and directed. 69 S&F forSMC street light control box of size 300 x 200 x105 mm including aluminium bus bar of adequate capacity and one no. MCB SP 16 Amps 230 volts including connecting up with the electrical connections and fixing and clampingincluding taking out old Unsv junction box etc complete all as specified and directed at site by Engineer-in-charge. 70 Supply, install, testing & commissioning LT feeder pillar box (KIOSK) outdoor type, plateform mounted, compartmentalised and confirming to IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having busbar chamber with insulated copper busbars 63 Amps rating not less than 60cm long installed on porcelein insulators. The panel shall be dust and vermin proof, made of 3.15 mm CRCA MS sheet and with base frame of 40x40x5 mm angle iron, powder coated finish over two coat of red oxide primer, front and rear opening type with aprons for cable entry with double door shutter and locking arrangement including a lock with two keys, internal wiring with PVC insulated multi stranded copper conductor cable,FRLS cables ISI marked of adequate size but not less than 2.5 Sqmm. The scope of work also includes following alongwith PCC foundation complete all as specified and directed 71 LIGHTING PROTECTIONS&F forceramic/ bakelite insulator base for supporting aluminium strip complete on roof surface/ wall surfaceof lightning protection system etc complete all as specified and directed. 72 SUMMER APPLIANCES & AIR CONDITIONINGSupply and fixing Voltage stablizer for automatic operation single phase naturally air cooled indoor type and designed for input variatiion between 170 volts to 250 volts with output voltage stabilized at 230 volts with accuracy of+/- 2.5% of capacity 1 KVA. etc complete all as specified and directed. 73 Supply and fixing Single door refrigerator electric driven single phase 230 volts, AC 50 Hz,of capacity 195 litre or next available higher capacity with BEE approved, 5 star rating with inbuilt stablizer complete including electric connection etc complete all as specified and directed. 74 Design, supply, installation, testing and commissioning of central air conditioning plant of working capacity not less than 25/26 TR (2x25/26 TR working + 1x25/26 TR standby) (As per standard design) to achieve the parameter as mentioned below including all civil works, mechanical, electrical unit and other allied equipments as per OEM comprising the following:(a) The desired temperature in air conditioning area ranges from 22(+/- 5) degree centigrade, humidity 55 (+/- 10) %.(b) Supply , install , commissioning and testing of Water Cooled Scroll Chillers, with multi compressors, comprising of Semi -Hermetic/Hermetic/ Open Type Compress ors, DX Evaporator, Shell and Tube Condenser,suitable expansion device,suitable for operation on R - 22 /R - 407 C/R 410a refrigerants and of nominal capacity.(c) The chilling machine shall be shell and tube condensor type, suitable expansion device, suitable for operation on R407c/ R 410a refrigerants and fitted with built in safety devices like HP/LP cut outs, oil pressure switch, cooler freeze protection, high discharge gas temperature cut outs, earth fault protection for compressor against erratic power supply (under voltage, over voltage, phase reversal, phase imbalance and protection against short circuitting & overloading)(d) The chilling machine is to be designed to operate at high ambient temperature & refrigerant piping shall be seamless, copper tubes formed on hydraulic bending dies to minimise blazed joints thereby ensuring a high level refrigent circuit tightness, with antifreeze/glycol. The chiller shall be installed on necessary RCC/PCC/ISMB foundation with vibration isolation pads to minimise vibration. 75 Supply, installation, commissioning and testing of monoblock centrifugal pump (2W+1S) of capacity 66 USGPM (approx) discharge at 15 mtr head with electric motor AC 3 phase 415 V/440V 50Hz, cap 5 HP complete for chilled water, including MS channel with suitable antivibration pad and finishing to foundation work as required at site and connect with suction/discharge pipe lines etc complete all as specified and directed. 76 Supply, installation, commissioning and testing of monoblock centrifugal pump (2W+1S) of cap acity 104 USGPM (approx) discharge at 20 mtr head with electric motor AC 3 phase 415 V/440V 50Hz, cap 5 HP complete for condensor water, including MS channel with suitable anti vibration pad and finishing to foundation work as required at site and connect with suction/discharge pipe lines etc complete all as specified anddirected. 77 Supply, installation, commissioning and testing of induced drafttop discharge counterflow type FRP cooling tower (Rectagular /round bottle shape) suitable for capacity 60 TR AC plant with FRP body and base, water spray headers, cooling tower fills, fan with motor, MS ladder upto groung level, making suction and discharge pipe line connection including support baserames/foundation work as per manufacturers standard instructions necessary RCC stagging/foundation etc complete all as specified and directed. 78 Supply, installation, commissioning and testing of factory built double skinned, sandwiched with 25mm fiberlass/thermo coal/puff insulation, section type horizontal AHUs with six row, deep coil suitable for 50/52 TR. AHU is to be fabricated out of powder galvanised steel sheet 24 gauge casing inner and outer with Penta Post type construction. The cooling coil shall have internally hatched copper tubes and dual sine wave aluminium fins with insulated drain pan. The blower section shall be completed with draw through type backward curved blower with TEFC type blower motor of suitable size with belt drive. The AHUs shall have high velocity pre-filters prior to cooling coil, spray type humudifier with suitable type pump motor, drift eliminator, capacity not less than 20000 CFM, complete with micron filters, PVC square type with humidification tank, humidity state digital thermostat, fire damper with fuible link, air damper manually operated, canvas connection MS/copper pipe and fitting as required, plenum chamber including inspection window and sitable size control cable for blower motor / heater/ humidity pump with suitable size of cable tray, foundation work, anti vibration pad, MS angle supports and other connected work, safety devices/controls as required at site and connect with suction / discharge pipe line including cutting welding work and required civil work, including air mixing chamber if required at site complete and all electrical equipment to be connectedcomplete all as specified and directed. 79 Supply and installation of the winter heating system with monsoon re heating with hot water Generator 35 KW with 2 Nos pump (1w+1s) alongwith making necessary connections etc complete all as specified and directed.(For Humidity control / winter heating) 80 Supply and fixing of 100 mm bore mild steel C grade pipe (heavy duty) including cutting and welding work complete including with fittings such as bend, tee, elbow, union, reducer etc as required at site and 25 mm nitrile sheet for thermallynsulated with elastomeric insulation of appropriate thickness wrapped with water-proof cloth complete all as specified and directed for Chiller pipe line and synthetic enamel paint for condender piping.etc complete all as specified and directed. 81 Supply and fixing of 80 mm bore mild steel C grade pipe (heavy duty) including cutting and welding work complete including with fittings such as bend, tee, elbow, union, reducer etc as required at site and 25 mm nitrile sheet for thermallynsulated with elastomeric insulation of appropriate thickness wrapped with water-proof cloth complete all as specified and directed for Chiller pipe line and synthetic enamel paint for condender piping.etc complete all as specified and directed. 82 Supply and fixing of 65 mm bore mild steel C grade pipe (heavy duty) including cutting and welding work complete including with fittings such as bend, tee, elbow, union, reducer etc as required at site and 25 mm nitrile sheet for thermallynsulated with elastomeric insulation of appropriate thickness wrapped with water-proof cloth complete all as specified and directed for Chiller pipe line and synthetic enamel paint for condender piping. etc complete all as specified and directed. 83 Supply and fixing of 50 mm bore mild steel C grade pipe (heavy duty) including cutting and welding work complete including with fittings such as bend, tee, elbow, union, reducer etc as required at site and 25 mm nitrile sheet for thermallynsulated with elastomeric insulation of appropriate thickness wrapped with water-proof cloth complete all as specified and directed for Chiller pipe line and synthetic enamel paint for condender piping. etc complete all as specified and directed. 84 Supply and install butterfly valve of CI of 100 mm borein the water pipe lines by providing flanges, short pieces of mild steel pipes, gaskets, nut bolts and washers etc complete all as specified and directed. 85 Supply and install butterfly valve of CI of 80 mm borein the water pipe lines by providing flanges, short pieces of mild steel pipes, gaskets, nut bolts and washers etc complete all as specified and directed. 86 Supply and install butterfly valve of CI of 65 mm borein the water pipe lines by providing flanges, short pieces of mild steel pipes, gaskets, nut bolts and washers etc complete all as specified and directed. 87 Supply and install butterfly valve of CI of 50 mm borein the water pipe lines by providing flanges, short pieces of mild steel pipes, gaskets, nut bolts and washers etc complete all as specified and directed. 88 Supply and install Non return valve (NRV) of CI of 80mm bore in the water pipe lines by providing flanges, short pieces of mild steel pipes, gaskets, nut bolts and washers complete all as specified and directed. 89 Supply and install Non return valve (NRV) of CI of 65mm bore in the water pipe lines by providing flanges, short pieces of mild steel pipes, gaskets, nut bolts and washers complete all as specified and directed. 90 Supply and install Non return valve (NRV) of CI of 50mm bore in the water pipe lines by providing flanges, short pieces of mild steel pipes, gaskets, nut bolts and washers complete all as specified and directed. 91 Supply and fixing Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both endsfor iron pipe or for unions and fixed of dia 20 mm complete all asspecified and directed. 92 Supply and fixing Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both endsfor iron pipe or for unions and fixed of dia 15 mm complete all asspecified and directed. 93 Supply and fixing Mild steel pot strainer of 100 mm bore in the pipe line including cutting/welding work as required at site for accommodation of MS pot strainer complete all as specified and directed. 94 Supply and fixing new Mild steel Y-strainer of 80 mm bore in the pipe line including cutting/welding work as required at site for accommodation of MS pot strainer complete all as specified and directed. 95 Supply and fixing new Mild steel Y-strainer of 65 mm bore in the pipe line including cutting/welding work as required at site for accommodation of MS pot strainer complete all as specified and directed. 96 Supply and fixing new Mild steel Y-strainer of 50 mm bore in the pipe line including cutting/welding work as required at site for accommodation of MS pot strainer complete all as specified and directed. 97 Supply and install pressure gauge in the pipe lines suitable for dia 15 mm pipe complete all as specified and directed.Note:- Size of pressure gauge shall be provided as per OEM ecommendation. 98 Supply and install thermometers in the pipe line suitable for dia 15 mm complete all as specified and directed.Note:- Specification of thermometers shall be as per OEM recommendation. 99 Supply, assembly and erection of PGI sheet with TDF flange/ C&SS rectangular/square duct made out of L shaped hollow profile,duly factory boxed, incl all accessories such as corner, cleat, carriage bolt, gasket and appropriate sealent on longitudenal joints etc complete of thickness 22 gauge sheet complete all aspecified and directed. 100 M&L for duct insulation with 25 mm thick open cell nitrile rubber (Class 1) material of density 140-180 kg / m³ & thermal conductivity of 0.047 W/mK having anti fungal and antimicrobial properties as specified and including the following:(a) M&L for cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage.(b) M&L for applying rubber based adhesive CPRX compound.(c) M&L for sealing of all longitudenal joints and circular overlaps with and including Aluminium foil tape 50 mm wide, to make the insulation leak proof.(d) M&L for securing the insulation with and including mechanically fastened nylon / steel straps of size 12 mm / 50 mm complete all aspecified and directed. 101 M&L for wraping glass cloth incl UV chemical coating over nitrilebber for exposed ducts for better mechanical protection andnsulation from sunlight for complete all as specified and directed.Note:- Thickness of glass cloth shall be provided as per OEM 102 M&L for suitable size of supply air grills as per manufacturers design with extruder aluminium powder coated with air volume control and bird screen dampers complete all as specified and directed.Note:- Size and type of air grills alongwith air volume shall be 103 Providing suitable size of return air grills as per manufacturers design with extruder aluminium powder coated without air volume control and with bird screen dampers complete all as specified and directed.Note:- Size of return air grills shall be provided as per OEM 104 Supply, install, testing and commissioning of LT control panel board, cubical type 415 Volt, 3 phase, 50 Hz, indoor type, floor mounted,weather proof fabricated out of 2.0 mm CRCA sheet, duly compartmentalized, cable ally, spray painted with powder coated paint and comprising of the following :-(a) MCCB 4 pole 250 amp, 415 volt, 25 KA - 01 No (Incommer)(b) MCCB 4 pole 100 amp, 415 volt, 16 KA - 03 No (Outgoing for 2 chiller unit and one spare)(c) MCCB 4 pole 40 amp, 415 volt, 16 KA - 03 No (Outgoing for cooling Tower, AHU and hot water generator)(d) MCCB 4 pole 25 amp, 415 volt, 16 KA - 08 No (Outgoing for 8 pumps)(e) Starter of suitable size and capacity including contactor, relay, timer, push button - 10 Nos (for 8 pumps, cooling tower motor, AHU blower motor etc)(f) Volt meter (0-500V) three phase, digital type with inbuiltselector switch -01 No .(g) Ammeter(0-500A) three phase, digital type with inbuiltselector switch with suitable capacity of CTs - 01 set.(h) ON/OFF indication LED lamp - Set of 03.(j) Single phase preventor - 10 Nos (for pumps, cooling towermotor, blower etc)(k) Grouting of panel including PCC foundation as required.(l) 4 Nos electrolytic copper bus bars of high conductivity proper insulated of 1 ½ times of the incoming capacity with provision of extension and mounting on porcelain support.(m) MCB SPN 20A -01 No (for 3 way valve) 105 Supply and install 3 way valve of CI of size 80 mm dia in the water pipe lines for AHU by providing flanges, short pieces of mild steel pipes, gaskets, nut bolts and washers incl making connection from panel with suitable size cable complete all as specified and directed. 106 DG SETSupply install testing and commissioning of diesel Engine driven generating set 82.5 KVA capacity, 3 phase, 4 wire, 440 V, 1500 RPM, 50 Hz power supply with power factor 0.8 coupled directly to alternator mounted on a common base plate complete with integrated acoustic enclosureshaving salient features modular bolted construction with fabrication on imported CNC turrert punch machines, Nine tank treatment process with pure polyester based powder coating to ensure long life in all weather conditions and for outdoor application/installation. Integrated design thereby facilitating/easy handling installation and shifting oftheeqpt at site.The designof integrated acoustic enclosure should be of type approvedby National physical laboratory as per central pollution control board (CPCB) latest norms/regulation with fuel tank, battery and standard accessories including cost of PCC (1:2:4) type B-1foundation for(acoustic enclosures foundation Height shall be 800 mm out of which 500 mm shall be above ground level) as recommended by manufacturer ,Vibration pad sand cushioning around PCC foundation etc all and Tools and spares as provided bymanufacturer all as specified and as directed with the following specifications :-. 107 (A)ENGINE :Water cooled with radiator diesel Engine (confirming to IS : 10001/10002)of 1500 RPM capacity to match the 82.5 KVA alternator under NTP conditions with provisionof 10% overload for 1 hour in every 12 hours runningconforming toIS 6514/ IS 10001 / 10002 the Engine shall consist of the following:-(i) Fly wheel(ii) Flexible coupling with guard bolts and nuts etc(iii) Air cleaner heavy duty dry type(iv) Radiator with guard and water pump engine mounted(v) Dynamo of suitable capacity.(vi)Air cleaner heavy duty dry. 108 (vii) Fuel injection pump.(viii)Radiator fan (Blower type) with guard.(ix) Electronic/ A1 class governor.(x)Fuel filter (Mounted).(xi) Lubricating oil filter (mounted).(xii)12V self regulating alternator belt driven by engine.(xiii)Exhaust silencer heavy duty residential type(xiv)Corrosion resistor / scale inhibitor.(xv) Starter 12 VDC.(xvi)Lubricating oil cooler.(xvii) Lubricating oil pump (Gear type).(xviii)Turbo Charger(xix)Exhaust piping shall be insulated with asbestos rope duly cladded with aluminum sheet.xx)Instrument panel complete with the following:-(a) Auto manual starting switch with key.(b)Lubricating oil temperature gauge.(c) Lubricating oil pressure gauge.(d) Water temperature gauge.(e) Battery charging ammeter.(f) Battery charging indicating lamp.(g) Hour meter with RPM indicator.(h) Safety control against high temperature of water.(i) Safety control against high temperature of water.(j) Safety control against low lubricating oil pressure.(k) Over speed stop with double driven adaptor.(l) Over load 109 (B) BRUSH LESS ALTERNATOR(i)Alternator coupled to Engine through a flexible coupling to an indigenous alternator mounted on strong steelfabricated base frame suitable for mounting on a permanent foundation brushless alternator shall be conforming to BS-2613 or relevant IS-13364(ii) Type:- Self excited self regulated with automatic voltage regulator.(iii)Rating:- 82.5 KVA at 0.8 PF lagging 4 pole horizontal at NTP condition 3(iv) Speed:- 1500 RPM(v)System:- 415 Volts +/- 2.5% AC 3 Phase 4 wire 50 Hz. 110 (vi) Connection :-4 wire star connected.(vii) Enclosure :-Screen protected dip proof.(viii)Ventilation :-Self ventilated(ix)Insulation :-Insulation Class H(C) CONTROL PANELPanel forDG set factory fabricated & factory assembled out of sheet steel 2 mm thick, suitable for floor mounting, with suitable rated bus-bar made of copper strip, internal wiring and with copper conductor and labeling fuses with provision for connecting incoming/out going leads with the following accessories duly powder coated with following accessories:- (i) Incoming MCCB 4 pole 125 A 35 KA-1 Nos& bus bar of suitable capacity.(ii) DG set controller Microprocessor based graphical LCD display for monitoring and diagnostic all function of DG set with complete accessories (iii)DigitalAmmeter with CT and selector switch.(iv) DigitalVoltmeter0- 500 V.(v) LCD Display CT Operated 3 phKWH meter.(vi) Selector switch.(vii)Push button start stop reset(viii) Indicator lamps. 111 (ix) Battery charger internally fitted to charge batteries from mains(x) Transformer & rectifier.(xi) DC Volt meter & Ampere meter(xii) Charge rate selector trickle charge or high charge.(xiii) Indicator lamp battery(xiv) Changeover switch of suitable capacity.(D) AMF Panel cum Protection :- Separate Outdoor type AMF panel for automatic ON during power failure and off while power is on with adjustable time delay, panel totally enclosed fabricated out of CRCA sheet 3.15mm thick , over an angle iron frame made out of 50 x 50 x 6 mm anglewith removable side cover hinged front panel and rear panel of easyaccessibility complete withinternal wiring of suitable size copper conductor cable and cable glands for external connection and comprising of following :-(i) AMF relay &power contactors of suitable rating forautomatic starting on mains failure- 1 set 112 (ii) Digital type Frequency meter -1Nos(iii) RPM meter -1Nos(iv) Under Voltage relay-1No(v) Over voltage relay- 1No (vi) Reverse power relay- 1NO(vii) Trivector meter-1No(viii)Energy analyzer with CT- 1No(ix) Earth fault protection-1Nos(x) Under/Over frequency relay- 1No(xi) HRC type instruments fuses(xii) Copper bus bar of suitable size(E) FUEL TANK :- One No of sheet steel 14 SWG and capacity to hold diesel sufficient for running 16 hrs running at full load including necessary piping.(i) Level indicator on fuel tank(ii) Drain plug(iii) MS class C piping for inlet from pump to tank of engine(iv) Fuel strainer(v) Air vent. 113 (F)BATTERYAs recommended by manufacturers(G) Acoustic enclosure- Acoustic Enclosure suitable for 82.5 KVA DG set as under.i) Fabricated out of CRCA sheet of suitable thickness not less than 1.6mm. Polyester based powder coated internally and externally with lockable type door handle. All nuts and handles shall be zinc coated.ii) The doors are gasket with EPDM gaskets. The construction should be such that it prevent entry of rain water splashing in to enclosure and allows free and quick flow of rain water to the ground in the event of heavy rain,iii) Sound proofing with high quality rock wool/mineral wool confirming to IS 8183 ofdensity at 96 Kg /M3 covered with fiber glass cloth and perforated powder coats sheet specially designed alienators (Sound controller) at air entry and exit of the container noise level shall be not exceed 75 Db at 1 meter distance as per CPCB norms. iv) Adequate ventilation to meet air requirement for combustion and heat removal with provn of a blower. v) Emergency stop push button outside the container. 114 vi) Provn of light inside the canopy providing of FTL fitting 1x20 watt with wiring and control switch.vii) The canopy should be provided with height enclosure temperature safety device.(H) BASE PLATESturdy, fabricated welded construction out of MS channels ISMC of suitable size suitable for fixing of DG set, required anti-vibration mounting pads shall be provided all specified by the manufacturer.Note:- (i) DG setplatform is deem to be included with quoted rate The size / design ofplatform provided as per manufacturer recommendation . 115 Supply install testing and commissioning of diesel Engine driven generating set 25 KVA capacity, 3 phase, 4 wire, 440 V, 1500 RPM, 50 Hz power supply with power factor 0.8 coupled directly to alternator mounted on a common base plate complete with integrated acoustic enclosureshaving salient features modular bolted construction with fabrication on imported CNC turrert punch machines, Nine tank treatment process with pure polyester based powder coating to ensure long life in all weather conditions and for outdoor application/installation. Integrated design thereby facilitating/easy handling installation and shifting oftheeqpt at site.The designof integrated acoustic enclosure should be of type approvedby National physical laboratory as per central pollution control board (CPCB) latest norms/regulation with fuel tank, battery and standard accessories including cost of PCC (1:2:4) type B-1foundation for(acoustic enclosures foundation Height shall be 800 mm out of which 500 mm shall be above ground level) as recommended by manufacturer ,Vibration pad sand cushioning around PCC foundation etc all and Tools and spares as provided bymanufacturer all as specified and as directed with the following specifications :-. 116 (A)ENGINE :Water cooled with radiator diesel Engine (confirming to IS : 10001/10002)of 1500 RPM capacity to match the 25 KVA alternator under NTP conditions with provisionof 10% overload for 1 hour in every 12 hours runningconforming toIS 6514/ IS 10001 / 10002 the Engine shall consist of the following:-(i) Fly wheel(ii) Flexible coupling with guard bolts and nuts etc(iii) Air cleaner heavy duty dry type(iv) Radiator with guard and water pump engine mounted(v) Dynamo of suitable capacity.(vi)Air cleaner heavy duty dry. 117 (vii) Fuel injection pump.(viii)Radiator fan (Blower type) with guard.(ix) Electronic/ A1 class governor.(x)Fuel filter (Mounted).(xi) Lubricating oil filter (mounted).(xii)12V self regulating alternator belt driven by engine.(xiii)Exhaust silencer heavy duty residential type(xiv)Corrosion resistor / scale inhibitor.(xv) Starter 12 VDC.(xvi)Lubricating oil cooler.(xvii) Lubricating oil pump (Gear type).(xviii)Turbo Charger(xix)Exhaust piping shall be insulated with asbestos rope duly cladded with aluminum sheet.xx)Instrument panel complete with the following:-(a) Auto manual starting switch with key.(b)Lubricating oil temperature gauge.(c) Lubricating oil pressure gauge.(d) Water temperature gauge.(e) Battery charging ammeter.(f) Battery charging indicating lamp.(g) Hour meter with RPM indicator.(h) Safety control against high temperature of water.(i) Safety control against high temperature of water.(j) Safety control against low lubricating oil pressure.(k) Over speed stop with double driven adaptor.(l) Over load 118 (B) BRUSH LESS ALTERNATOR(i)Alternator coupled to Engine through a flexible coupling to an indigenous alternator mounted on strong steelfabricated base frame suitable for mounting on a permanent foundation brushless alternator shall be conforming to BS-2613 or relevant IS-13364(ii) Type:- Self excited self regulated with automatic voltage regulator.(iii)Rating:- 25 KVA at 0.8 PF lagging 4 pole horizontal at NTP condition 3(iv) Speed:- 1500 RPM(v)System:- 415 Volts +/- 2.5% AC 3 Phase 4 wire 50 Hz. 119 (vi) Connection :-4 wire star connected.(vii) Enclosure :-Screen protected dip proof.(viii)Ventilation :-Self ventilated(ix)Insulation :-Insulation Class H(C) CONTROL PANELPanel forDG set factory fabricated & factory assembled out of sheet steel 2 mm thick, suitable for floor mounting, with suitable rated bus-bar made of copper strip, internal wiring and with copper conductor and labeling fuses with provision for connecting incoming/out going leads with the following accessories duly powder coated with following accessories:- (i) Incoming MCCB 4 pole 63 A 35 KA-1 Nos& bus bar of suitable capacity.(ii) DG set controller Microprocessor based graphical LCD display for monitoring and diagnostic all function of DG set with complete accessories (iii)DigitalAmmeter with CT and selector switch.(iv) DigitalVoltmeter0- 500 V.(v) LCD Display CT Operated 3 phKWH meter.(vi) Selector switch.(vii)Push button start stop reset(viii) Indicator lamps. 120 (ix) Battery charger internally fitted to charge batteries from mains(x) Transformer & rectifier.(xi) DC Volt meter & Ampere meter(xii) Charge rate selector trickle charge or high charge.(xiii) Indicator lamp battery(xiv) Changeover switch of suitable capacity.(D) AMF Panel cum Protection :- Separate Outdoor type AMF panel for automatic ON during power failure and off while power is on with adjustable time delay, panel totally enclosed fabricated out of CRCA sheet 3.15mm thick , over an angle iron frame made out of 50 x 50 x 6 mm anglewith removable side cover hinged front panel and rear panel of easyaccessibility complete withinternal wiring of suitable size copper conductor cable and cable glands for external connection and comprising of following :-(i) AMF relay &power contactors of suitable rating forautomatic starting on mains failure- 1 set 121 (ii) Digital type Frequency meter -1Nos(iii) RPM meter -1Nos(iv) Under Voltage relay-1No(v) Over voltage relay- 1No (vi) Reverse power relay- 1NO(vii) Trivector meter-1No(viii)Energy analyzer with CT- 1No(ix) Earth fault protection-1Nos(x) Under/Over frequency relay- 1No(xi) HRC type instruments fuses(xii) Copper bus bar of suitable size(E) FUEL TANK :- One No of sheet steel 14 SWG and capacity to hold diesel sufficient for running 16 hrs running at full load including necessary piping.(i) Level indicator on fuel tank(ii) Drain plug(iii) MS class C piping for inlet from pump to tank of engine(iv) Fuel strainer(v) Air vent. 122 (F)BATTERYAs recommended by manufacturers(G) Acoustic enclosure- Acoustic Enclosure suitable for 25 KVA DG set as under.i) Fabricated out of CRCA sheet of suitable thickness not less than 1.6mm. Polyester based powder coated internally and externally with lockable type door handle. All nuts and handles shall be zinc coated.ii) The doors are gasket with EPDM gaskets. The construction should be such that it prevent entry of rain water splashing in to enclosure and allows free and quick flow of rain water to the ground in the event of heavy rain,iii) Sound proofing with high quality rock wool/mineral wool confirming to IS 8183 ofdensity at 96 Kg /M3 covered with fiber glass cloth and perforated powder coats sheet specially designed alienators (Sound controller) at air entry and exit of the container noise level shall be not exceed 75 Db at 1 meter distance as per CPCB norms. iv) Adequate ventilation to meet air requirement for combustion and heat removal with provn of a blower. v) Emergency stop push button outside the container. 123 vi) Provn of light inside the canopy providing of FTL fitting 1x20 watt with wiring and control switch.vii) The canopy should be provided with height enclosure temperature safety device.(H) BASE PLATESturdy, fabricated welded construction out of MS channels ISMC of suitable size suitable for fixing of DG set, required anti-vibration mounting pads shall be provided all specified by the manufacturer.Note:- (i) DG setplatform is deem to be included with quoted rate The size / design ofplatform provided as per manufacturer recommendation . 124 Supply install testing and commissioning of diesel Engine driven generating set 30 KVA capacity, 3 phase, 4 wire, 440 V, 1500 RPM, 50 Hz power supply with power factor 0.8 coupled directly to alternator mounted on a common base plate complete with integrated acoustic enclosureshaving salient features modular bolted construction with fabrication on imported CNC turrert punch machines, Nine tank treatment process with pure polyester based powder coating to ensure long life in all weather conditions and for outdoor application/installation. Integrated design thereby facilitating/easy handling installation and shifting oftheeqpt at site.The designof integrated acoustic enclosure should be of type approvedby National physical laboratory as per central pollution control board (CPCB) latest norms/regulation with fuel tank, battery and standard accessories including cost of PCC (1:2:4) type B-1foundation for(acoustic enclosures foundation Height shall be 800 mm out of which 500 mm shall be above ground level) as recommended by manufacturer ,Vibration pad sand cushioning around PCC foundation etc all and Tools and spares as provided bymanufacturer all as specified and as directed with the following specifications :-. 125 (A)ENGINE :Water cooled with radiator diesel Engine (confirming to IS : 10001/10002)of 1500 RPM capacity to match the 30 KVA alternator under NTP conditions with provisionof 10% overload for 1 hour in every 12 hours runningconforming toIS 6514/ IS 10001 / 10002 the Engine shall consist of the following:-(i) Fly wheel(ii) Flexible coupling with guard bolts and nuts etc(iii) Air cleaner heavy duty dry type(iv) Radiator with guard and water pump engine mounted(v) Dynamo of suitable capacity.(vi)Air cleaner heavy duty dry. 126 (vii) Fuel injection pump.(viii)Radiator fan (Blower type) with guard.(ix) Electronic/ A1 class governor.(x)Fuel filter (Mounted).(xi) Lubricating oil filter (mounted).(xii)12V self regulating alternator belt driven by engine.(xiii)Exhaust silencer heavy duty residential type(xiv)Corrosion resistor / scale inhibitor.(xv) Starter 12 VDC.(xvi)Lubricating oil cooler.(xvii) Lubricating oil pump (Gear type).(xviii)Turbo Charger(xix)Exhaust piping shall be insulated with asbestos rope duly cladded with aluminum sheet.xx)Instrument panel complete with the following:-(a) Auto manual starting switch with key.(b)Lubricating oil temperature gauge.(c) Lubricating oil pressure gauge.(d) Water temperature gauge.(e) Battery charging ammeter.(f) Battery charging indicating lamp.(g) Hour meter with RPM indicator.(h) Safety control against high temperature of water.(i) Safety control against high temperature of water.(j) Safety control against low lubricating oil pressure.(k) Over speed stop with double driven adaptor.(l) Over load 127 (B) BRUSH LESS ALTERNATOR(i)Alternator coupled to Engine through a flexible coupling to an indigenous alternator mounted on strong steelfabricated base frame suitable for mounting on a permanent foundation brushless alternator shall be conforming to BS-2613 or relevant IS-13364(ii) Type:- Self excited self regulated with automatic voltage regulator.(iii)Rating:- 30 KVA at 0.8 PF lagging 4 pole horizontal at NTP condition 3(iv) Speed:- 1500 RPM(v)System:- 415 Volts +/- 2.5% AC 3 Phase 4 wire 50 Hz. 128 (vi) Connection :-4 wire star connected.(vii) Enclosure :-Screen protected dip proof.(viii)Ventilation :-Self ventilated(ix)Insulation :-Insulation Class H(C) CONTROL PANELPanel forDG set factory fabricated & factory assembled out of sheet steel 2 mm thick, suitable for floor mounting, with suitable rated bus-bar made of copper strip, internal wiring and with copper conductor and labeling fuses with provision for connecting incoming/out going leads with the following accessories duly powder coated with following accessories:- (i) Incoming MCCB 4 pole 100 A 35 KA-1 Nos& bus bar of suitable capacity.(ii) DG set controller Microprocessor based graphical LCD display for monitoring and diagnostic all function of DG set with complete accessories (iii)DigitalAmmeter with CT and selector switch.(iv) DigitalVoltmeter0- 500 V.(v) LCD Display CT Operated 3 phKWH meter.(vi) Selector switch.(vii)Push button start stop reset(viii) Indicator lamps. 129 (ix) Battery charger internally fitted to charge batteries from mains(x) Transformer & rectifier.(xi) DC Volt meter & Ampere meter(xii) Charge rate selector trickle charge or high charge.(xiii) Indicator lamp battery(xiv) Changeover switch of suitable capacity.(D) AMF Panel cum Protection :- Separate Outdoor type AMF panel for automatic ON during power failure and off while power is on with adjustable time delay, panel totally enclosed fabricated out of CRCA sheet 3.15mm thick , over an angle iron frame made out of 50 x 50 x 6 mm anglewith removable side cover hinged front panel and rear panel of easyaccessibility complete withinternal wiring of suitable size copper conductor cable and cable glands for external connection and comprising of following :-(i) AMF relay &power contactors of suitable rating forautomatic starting on mains failure- 1 set 130 (ii) Digital type Frequency meter -1Nos(iii) RPM meter -1Nos(iv) Under Voltage relay-1No(v) Over voltage relay- 1No (vi) Reverse power relay- 1NO(vii) Trivector meter-1No(viii)Energy analyzer with CT- 1No(ix) Earth fault protection-1Nos(x) Under/Over frequency relay- 1No(xi) HRC type instruments fuses(xii) Copper bus bar of suitable size(E) FUEL TANK :- One No of sheet steel 14 SWG and capacity to hold diesel sufficient for running 16 hrs running at full load including necessary piping.(i) Level indicator on fuel tank(ii) Drain plug(iii) MS class C piping for inlet from pump to tank of engine(iv) Fuel strainer(v) Air vent. 131 (F)BATTERYAs recommended by manufacturers(G) Acoustic enclosure- Acoustic Enclosure suitable for 30 KVA DG set as under.i) Fabricated out of CRCA sheet of suitable thickness not less than 1.6mm. Polyester based powder coated internally and externally with lockable type door handle. All nuts and handles shall be zinc coated.ii) The doors are gasket with EPDM gaskets. The construction should be such that it prevent entry of rain water splashing in to enclosure and allows free and quick flow of rain water to the ground in the event of heavy rain,iii) Sound proofing with high quality rock wool/mineral wool confirming to IS 8183 ofdensity at 96 Kg /M3 covered with fiber glass cloth and perforated powder coats sheet specially designed alienators (Sound controller) at air entry and exit of the container noise level shall be not exceed 75 Db at 1 meter distance as per CPCB norms. iv) Adequate ventilation to meet air requirement for combustion and heat removal with provn of a blower. v) Emergency stop push button outside the container. 132 vi) Provn of light inside the canopy providing of FTL fitting 1x20 watt with wiring and control switch.vii) The canopy should be provided with height enclosure temperature safety device.(H) BASE PLATESturdy, fabricated welded construction out of MS channels ISMC of suitable size suitable for fixing of DG set, required anti-vibration mounting pads shall be provided all specified by the manufacturer.Note:- (i) DG setplatform is deem to be included with quoted rate The size / design ofplatform provided as per manufacturer recommendation . 133 CRANEDesign,supply, erection & installation, testing and commissioning indoor type, heavy duty, electrically operated,Double box girder type over head traveling Crane (EOT) designed & manufactured in accordance to IS-3177 of 1999 & IS-807 of 2006 and having motormain host:- 7.HP, Long Travel motor 2.00HP, Cross travel 1.0 HP, limit switch rotary + greavity, wheel double flanged, En +-9 Forged (Heat Treated) conforming to IS-2148, class-ll capable to handle 2.0 ton load (SWL)with centre to centre clear span 6 metres (cross travel), andlongitudinal travel 26 meters; suitable for operation on 415 volts 3 phase 4 wire AC supply system; with necessary steel supporting structure with clear hook height 4.0 metres from FFL; including all electrical components, control, Cables Safety Control etc, floor operated with moveable pendant control to be operated by means of push buttons from floor level independantly of crab position with protective panel including down shop lead (DS) trailing cable for CT motion and DSL of fastoon type with FRLSH cable for LT motion complete all as specified including painting with fire resistant, paint all as per manufacturers specification all as per standard norms for the technical parametres and specification. 134 (i) Considering large span of the crane, Fabrication work ofcrane girder can be done at site. The joint will however not to beprovided at the same points of maximum (ii). The wheel & hook should be coated with non-ferrous metal to avoid metal to metal contact. (iii). Required speed are as below:a) Host: Main speed 3m/min, Creep speed 1m/min. b) Cross travel: Main speed 10m/min, Creep speed 2m/min.c) Longitudinal travel: Main speed 10m/min, Creep speed 2m/min.(iv). Contractor/Manufacturer shall be provided dummy load for crane with the crane, the load shall be of SWL +25% overloads.(v). For load testing of cranes, load shall be arranged by contractor and shall be done as per prevailing IS. (vi) Rate of rail section deemed to be included in the quoted rates of crane.(vii). The cranes shall be inspected and certified by reputed firm at the premises of manufacturers/after installation at site. Note: The cost of girder deemed to be included in the quoted rate. 135 CRANEDesign,supply, erection & installation, testing and commissioning indoor type, heavy duty, electrically operated,Double box girder type over head traveling Crane (EOT) designed & manufactured in accordance to IS-3177 of 1999 & IS-807 of 2006 and having motormain host:- 20HP, Long Travel motor 3.00HP, Cross travel 3.0 HP, limit switch rotary + greavity, wheel double flanged, En +-9 Forged (Heat Treated) conforming to IS-2148, class-ll capable to handle 5.0 ton load (SWL)with centre to centre clear span 7 metres (cross travel), andlongitudinal travel 21 meters; suitable for operation on 415 volts 3 phase 4 wire AC supply system; with necessary steel supporting structure with clear hook height 2.0 metres from FFL; including all electrical components, control, Cables Safety Control etc, floor operated with moveable pendant control to be operated by means of push buttons from floor level independantly of crab position with protective panel including down shop lead (DS) trailing cable for CT motion and DSL of fastoon type with FRLSH cable for LT motion complete all as specified including painting with fire resistant, paint all as per manufacturers specification all as per standard norms for the technical parametres and specification. 136 (i) Considering large span of the crane, Fabrication work ofcrane girder can be done at site. The joint will however not to beprovided at the same points of maximum (ii). The wheel & hook should be coated with non-ferrous metal to avoid metal to metal contact. (iii). Required speed are as below:a) Host: Main speed 3m/min, Creep speed 1m/min. b) Cross travel: Main speed 10m/min, Creep speed 2m/min.c) Longitudinal travel: Main speed 10m/min, Creep speed 2m/min.(iv). Contractor/Manufacturer shall be provided dummy load for crane with the crane, the load shall be of SWL +25% overloads. (v). For load testing of cranes, load shall be arranged by contractor and shall be done as per prevailing IS. (vi) Rate of rail section deemed to be included in the quoted rates of crane.(vii). The cranes shall be inspected and certified by reputed firm at the premises of manufacturers/after installation at site. Note: The cost of girder deemed to be included in the quoted rate.
Contract Date: Mar 10, 2026 Contract Value : 13.15 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
50.
Defence #9618268 AOC
Tender For Special Repair To Bldg No Ts-02 (01 To 04) Or Md Accn At Mandir Line Of Static Wksp Eme Under Ge (Awc) Mhow; 1 Demolition of un-reinforced Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. 2 Demolition of cement concrete (reinforced) as in roof, floors (other than ground floor) beams, staircase, landing, chajjas and similar suspended work complete. 3 Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) and rubbish of the premises complete all as specified and directed. 4 M&L for Scratch free, double charged, vitrified ceramic tiles9 to 10mm thick (square or rectangular) area of each tile not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layerin CM 1:6 complete all as specified and as directed. 5 M&L for Coloured Non Skid ceramic joint freetiles 7 to 8 mm thick (Square/ Rectangular) area of each tile exceeding 0.06 Sq. M but not exceeding 0.18 Sq. M, in floors etc,including 15 thick screed bedset and jointed in neat cement slurry and pointedin white or coloured cement to match the shade of the tile complete all as specified and as directed. 6 S&F Glazed ceramic tiles in vertical surface 450 x 350x 7 mm thick ,including 10 mm thick secreed bed set and jointed in neat cement slurry and pointed in white or cloured cement complete all as specified and as directed.Note : Rate includes for cuttingfor offsetsetc) complete all as specified and as directed. 7 M&L for Hard core of guage n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed. 8 M & L for 75 mm thick PCC 1:3:6 type C2 (Using 40mm graded granite stone aggregate) as in plinth protection finishd even and smooth with out using extra cement complete all asspecified and directed. 9 M&L for 50 mm thick cement concrete type B-1, 1:2:4 (using 20mm graded aggregate) surface finished even and smooth without using extra cement complete all as specified and directed. 10 Material and Labour Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;complete all as specified and directed. 11 M&L for Pre Cast Cement Concrete 1:2:4 type B1 (using 20 mm graded aggregate) as in Kitchen platform and Cover slab for manholes etc set in cement mortor 1:4 including use and waste necessary form work (Reinforced shall be measured and paid seprately) all as specefied 12 M&L for cement concrete Type C21:2:440 mm graded stone aggegate as in footingscolumns ,beams walls CM1:4 including use and waste necessary form work (Reinforced shall be measured and paid seprately) all as complete all as specified and directed. 13 M & L for Form work to sides of foundation / slabs / base of columns plinth beams and similar work with fair finished surface complete all as directed. 14 M&L for mild steel TMT bars 10mm dia and over, cut to length bent to shap required including cranking, bending spirally for hooping for columnshooking ends and binding with and including mild steel wire (annealed not less than 0.9 mm dia or securing with clips complete all as specified and directed. 15 Description all as per ser item No. 14.00 above but 5mm dia and over upto and incl 10 mm dia in spacers, stirrups and binders complete all as specified and directed. 16 M&L for granite slabs 20mm thick machine cut bedded laid over cement screed 15mm thick in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of slab incl grinding moulding rounding chamfering and polishing complete all as specified and directed. 17 M&L for machine cut Cudappastone slab flooring 20-25mm thick laid over and including 20mm thick screed bed in CM 1:6and jointed with grey cement slurry mixed with pigments to match the shade of the slab including rubbing and polishing with beeswax polish complete all as specified and as directed. 18 M&L for Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed. 19 Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc complete all as specified and directed. 20 M & L for brick work with sub-class `B bricks, straight or curved burnt clay brickson plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and directed. 21 M&L for brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1: 4 complete all as specified and directed. 22 Taking down cement plaster on wall of any description incl racking out joints for key, scrubbing with water etc. complete all as specified and directed. 23 M & L for rendering 15mm thick in cement mortor 1:4 on concrete or brick wall surfaces, finished even and smooth without using extra cement, mixed with WPC @ at 3% by weight of cement (IWPC measured and paid separately) complete all as specified and directed. 24 Supply only integral water proofing compound. 25 M & L for rendering 10mm thick in cement mortor 1:6 on Brick wall surfaces, finished even and smooth without using extra cement complete all as specified and directed. 26 M&L for 15 mm thick cement plaster in cement mortar 1:6 on brick or concrete surface etc. on wall finished even and smooth without using extra cement, all as specified . 27 Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundation etc or for shafts wells, cesspits, manholes, pier holes etc not exc 10sqm on plan and getting out in hard/dense soil complete all as specified and directed. 28 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with all kind of soil complete all as specified and directed. 29 M&L for removing excavated surplus soil n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed. 30 M&L for PCC type D2 1:4:8 (using 40mm graded stone aggregate) as in foundations, filling and mass Concrete complete all as specified and directed. 31 Taking down chowkats with shutters (without taking off shutters from the frameexc 1.5 Sqm and n.exc 4 Sqm each complete all as specified and directed. 32 Description all as per ser item No. 31.00 above in before but n exc 1.5 Sqm complete all as specified and directed. 33 S&F Pressed steel frames 125x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified and directed. 34 S&F pressed steel door frames of size 105 x 60mm, made of 1.25mm thick sheet, for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate,etc complete all as specified as directed. 35 S&F IInd class hardwood panelled shutters of 40mm thick (any number of panesl) with panels of timber flat on both sides (feathered edged0 or of veneeered particle boad medium density, wood particle board with commercial face veneers, complete all as specified and as directed. 36 Providing“RAJSHRI” Brand Factory Made 35 mm thick 100% Solid WPC ( Wood polymer Composite ) Laminated Flush Door Shutter of required size comprising ofvirgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cbmmanufactured by RAJSHRI an ISO 9001 - 2015 Certified Company, having good screw holding capacity ( Screw Withdrawal strength of 50 N ( Face ) & 1100 N ( Edge ), Minimum Compissive of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutterand fixing stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws,incl chowkhtas All as per direction of Engineer -In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company :For WC/Bathroom/Toilet/Kitchen/Balcony Doors. 37 Providing30 mm thick RAJSHRI BRAND FACTORY MADE WIRE MESHSOLID WPCDOOR SHUTTER consisting ofDensity 500 Kg /CbmManufactured by an ISO-9001-2015 certified Company , Door to be panelled with SS mosquito Mesh and XTN aluminium Mesh for additional strength and safety purpose.(confirming as per IS:4020). The door should be water proof, termite proof, fire retardant and having screw holding capacity. Door to be fixed to frame with 3 nos. M.S powder coated butt hingessize 100mm*25mm*2mm and 32mm long steel screws drilled suitable to pass through both the walls of the M.S tube.Other hardwares should be fixed with 19*6mm size steel screws etc. Complete as per direction of Engineer-in -charge, manufacturers specification & drawings. 38 Material and labour Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specificationall as directed. 39 Material and labour Factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside complete all as specifed and as directed. 40 Material and labour Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed withn wooden beading or with nuts and bolts to existing steel windows/wooden windows complete all as specifed and as directed. 41 S & F powder coated aluminium ventilator cross section conforming to IS 63.5x38.10x1.5mm consisting of two partions upper portion shall have louvers with 3mm thick pin headed glass and aluminium wire cloth 0.30mm nominal dia of wire and average width of aperture 1.56m fixed with aluminium beads and securing on outer face of frame and lower portion of ventilation shall be fixed with 3mm thick pin headed glass with IDPE rubber gasket including aluminium beads, including preparation of jombs all around in CM 1:3 finishing even and smooth complete all as specified and directed. 42 S & F Powder coated aluminium sliding glazedwindows with three track shutter sliding (two shutters glazed and one shutterwire mesh) shall be following specification complete all as specified and as directed by Engr-in-charge.(i)Windows frame of cross section 101mm x 44mm x 1.5mm thick.(ii)Three way track for sliding shutters of cross section91.8mm x 31.75mm x1.1mm thick.(iii)Sliding shutter frame of cross section40 x 18 x 1mm thick.(iv)4 mm thick tintedglass superior quality.(v) IDPE Rubber guasket for fixing of glass.(vi)Locking cleats per shutter -01 Nos.(vii)Sliding rollers per shutter - 02 Nos.including satety steel grill(viii) Aluminium wire cloth 0.30mm nominal dia of wire and average width of aperture 1.56mm for shutters 01 Nos. 43 M&L for 5.5mm thick sheetglassn exc 0.50sqm in area to be fixed in Alluminiumwindows complete all as specifed and as directed. 44 S&F 300mm length, aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specifed and as directed. 45 S&F 250 mm length, aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specifed and as directed. 46 S&F100 mm size of Butt hinges, medium weight cold rolled mild steel complete door etc complete all as specified and directed. 47 S&F aluminium anodised barrel tower bolts of extruded section with 100 mm long bolt, all as specified . 48 S&F aluminium anodised barrel tower bolts of extruded section with 200 mm long bolt, all as specified . 49 S&F aluminium anodised barrel tower bolts of extruded section with 150 mm long bolt, all as specified . 50 S&F Extruded aluminium alloy handles fabricated type anodised 150mm size complete all as directed and specifiedand as directed. 51 S&F Extruded aluminium alloy handles fabricated type anodised 100mm size complete all as specified and as directed. 52 M&L for floor door stopper of brass body and tongue, anodised, with hard drawn steel spring, 140mm long, fixed in floor complete all as specified & as directed. 53 S&F hasp and staple 125mm, safety type, aluminium anodised with alu hinge pin incl bolt to hinge plate and fixed with screws all as specified and as directed. 54 M&L for 2nd Class hardwood plain fillets, square or triangular in section, clean swan, secured with nails or brads, croos sectional area exc 13 Sqcm but Not Exc 25 Sqcm complete all as specified and directed. 55 Material and labour Second class hard wood Plain fillets square, rectangular or triangular in section clean swan, Exc 6 & n exc 13 sq. cm secured with mails brads,Wooden Barear 25X40mmcomplete all as specifed and as directed. 56 Material and labour 19mm thick Particles boards, medium density, flat pressed, single layer type or three layer, BWR grade complete all as specified and directed. 57 S&F in repairs 18/19mm thick prelaminatedparticle board interior grade / sprelaminated one side with decorative choice lamination and other side balancing white lamination fixed with nails to timber frame work complete all as specified and directed. 58 Extra over rates of block board or veneered particle board of (18/19mm ) for external teak wood lipping 6mm thick fixed with nails complete all as specified and directed. 59 S & F Continuous (piano) hinges,mild steel, bright finish or electro galvanised, Width of flaps (when open) in 30 mm etc complete all as specified and directed. 60 S & F 75mm thick Extruded aluminium alloy handles, fabricated type,anodised, etc complete all as specified and directed. 61 S & F brass 2-levers locks for cupboard, grade I of size 50mm complete all as specified and directed. 62 S & F 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finished and brass polished complete all as specified and directed. 63 S&F fanlight magnetic catch with 14mm catch cast brass and fixed to cupboard shutters all as specified and as directed 64 S& F 18 mm thick factory made PVC sheet one side pre laminated sheet kitchen cabinet shutter/cupboard shutter.The 18mm thick sheet shutter bent at 90 degree and finish all edges at level for making edge lipping bending for 0.5 mm thick PVC sheet lipping at all four edges using bodning etc complete all as specified and directed. 65 S&Ffactory made PVC shelf/partition of required size consisting of panel of 12 mm thick celuka PVC ply and for supporting the hold of shelf/partition and shall provide 3 edges in size 18mm x 18mm as per required length the front side of the edge visible in the fronth of the self / partition to be edge lipped by 18mm width x 1 mm thick PVC sheet of density 600kg/cum manufactured by ISO 9001-2015 Certified company using solvent cement etc complete all as specified and as directed. 66 S&F stainless steel shelf closing hinges 75 mm size for PVC door shutters complete all as specified and directed 67 S&F 50 x 15 mm size magnet door catcher for closing for PVC door shutter complete all as specifid and directed . 68 S& F 100 mm size MS mat/glossy finish handle complete all as specfied and directed . 69 S&F modular type stainless steel cutlery basket size 20 x 19 x 4 inches (dia of wire not less than 3.00 mm) of any shape withside sliding roller clip and silding rails on both side fixed with steel screws incl all fixing arrangements complete all as specified and directed. 70 Description all as per ser item No. 69.00 above but cup and saucer basket size 20 x 17 x 4 inches complete all as specified and directed. 71 Description all as per ser item No. 69.00 above but plain basket size 20 x 19 x 6 inches complete all as specified and directed. 72 Description all as per ser item No. 69.00above but grain basket size 20 x 17 x 6 inches complete all as specified and directed. 73 Description all as per ser item No. 69.00 above but thali basket size 20 x 19 x 8 inches complete all as specified and directed. 74 Description all as per ser item No. 69.00above but plain basket size 20 x 17 x 8 inches complete all as specified and directed. 75 M & L forform work to sides of concrete foundation including rafts, footings, foundation beams, bases of columns etc for fair finished surface complete all as specified. 76 S&F Harrison rails ,mildstainless steel curtain rod cromium platedwith brackets 25mm dia including necesary SS clamp complete all as specified & asdirected. 77 Taking down 15mm bore steel tubing and connections in any position, Complete all as specified and directed. 78 Taking down 20mm bore steel tubing and connections in any position, Complete all as specified and directed. 79 Cutting chases, pinning in, making good to facings where required & pointing in cement mortar 1:3 for concealed water tubing, etc.& making good, cutting not exc 10 cm grith 80 Supplying and fixing of 16mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including provision of special fittings ( Unions, elbow, Tee, Male threaded brass adaptor, Female threaded brass adaptor, Tank adaptor etc), complete all as specified 81 Supplying and fixing of 20mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including provision of special fittings ( Unions, elbow, Tee, Male threaded brass adaptor, Female threaded brass adaptor, Tank adaptor etc), complete all as specified 82 M&L for 20 mm bore GI Tubing medium grade with all fittings fixed to wall/ ceiling or in floor complete as specified and directed. 83 S&F in repair rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 2000 ltrs capacity hoisted and fixed in position all as specified including dismantling old500 ltr water tank complete all as specified and directed. 84 S&F 20 mm dia brass ball valve, high pressure with polythene float and fly-nut complete, screwed for iron pipe or brass ferrule fixed in repair complete all as specified and directed. 85 S&F in repair 20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 86 S & Fin repair 15mm bore Bib taps, chromium plated cast copper alloy but fancy type, screwed down, screwed for iron pipe or for brass ferrule complete allas specified and directed. 87 S&F in repairs 15 mm diafancy type stop valves/ angle cock chromium plated screwed down, high pressure,screwed both ends for iron pipe or for unions and fixed complete allas specified and directed. 88 S&F Long body CP Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. 89 S&F angular stop valves, cast copper alloy, screwed down, high pre-ssure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. 90 S&F Bib taps, cast copper alloy with crutch or butterfly handle, sc-rewed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. 91 S&F Brass CP wall mixer for mixing hot & cold water screwed down for iron pipe and fixedcomplete all as specified and as directed. 92 S&F Brass CP Tubular towel rail, 20mm dia, D type, 60cm long between flanges fixedcomplete all as specified and as directed. 93 S&F chromium plated shower roses 125mm sizes with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed. 94 M&L for Health faucet (ABS Bpdy) mild steel chromium plated suitable for 15mm dia pipe 1.25 M long flexible tube and ABS wall Hook including making connection and fixed in position with two way tap complete all as specified and as directed. 95 S&Fin repairs stainless steel Kitchen sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mmincluding necessary PVC outlet pipe and coupling complete all as specified and directed. 96 S & F in repair stainless steel plate rack 31 X 36 X 10 made up of 1mm thick sheet (Non magnetic) complete all as specified and directed. 97 S&F in repairs Vitreous China squatting pan , Orissa pattern size 580 X 440 mm white with intgrel footrest (excluding flushing cistern 10 ltr capacity & flush pipe) with 110mm dia PVC SWR P or S trap, fixing of cistern, complete including provision of cement concrete all as specified and directed. 98 S&F in repairs for vitreous china wash basin, white, flat back size 550 x 400mm including 01 Nos cast copper alloy 15mm CP fancy type pillartap, 01 Nos 32mm waste coupling , one pair of MS bracket, cuttingfor and pinning in ends of brackets complete all as specified and directed. 99 Supply and fix in repairs PVC valveless syphonic action type flushing cistern 10 lit capacity low level white with inlet, ball valve, float and handle including brackets and32mm PVC flush pipe complete all as specified and directed. 100 S&F in repairs PVC connection 15mm dia, 45 Cms long with brass ferrules on both ends fixed complete all as specified and directed. 101 S & F brass chromium plated tubular towel rail 20 mm dia ‘D’ type 60 cm long between flanges ofbrass chromium plated complete all as specified and directed. 102 Supply and Fix in repairs PTMT Shelf of weight not less than 300 gms with soap dish (tray) fixed with and including Chromium plated brass screws and wooden / plastic cleats etc., complete all as specified and as directed. 103 S&F in repairs 600mmx450mm belvelled edge looking mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood with PVC / alluminium frame and fixed to wooden plugs with chromum plated brass screws, cup washers, complete all specified and directed. 104 S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed. 105 S&F in repair 550mmx350mm PVC Cabinet Mirror with shelves of selected quality glass and fixed on walls to wooden plugs with chromium plated brass screws, cup washers complete all specified and directed. 106 S & FPVC( SWR ) pipes 110mm dia single socketed , in any lengthwith rubber ring joints as rainwater, soil waste and vent pipe (with all fittings) fixed to wall or laid in trenches incl taking down existing pipe complete all as specified and directed. 107 S & FPVC( SWR ) pipes 75mm dia single socketed , in any lengthwith rubber ring joints as rainwater, soil waste and vent pipe (with all fittings) fixed to wall or laid in trenches incl taking down complete all as specified and directed. 108 S&F in repair PVC (SWR) bends any radius 110mm bore complete all specified and directed. 109 S&F in repair PVC (SWR) bends with access door any radius 110mm bore complete all specified and directed. 110 S&F PVC (SWR) junction single (single T) equal or unequal with access door of bore 110mm complete all specified and directed. 111 S&F PVC(SWR) vent cowl 110mm bore complete all specified and directed. 112 S&F PVC (SWR)bends any radious 75 mm dia complete all specified and directed. 113 S&F PVC (SWR)bends with access door any radious 75 mm dia complete all specified and directed. 114 S&F PVC (SWR) junction single (single T) equal or unequal of bore75mm complete all specified and directed. 115 S & F in repairs PVC (SWR) Floor trap/Nahani trap plain or multi with stainless steel grating incl joinig to waste pipe with solvent cement joint dia of outlet 75 mm bore complete all as specified and directed. 116 S&F PVC (SWR) junction single (single T) equal or unequal with access door of bore75mm complete all specified and directed. 117 S&F in repair PVC (SWR) floor trap 75mm dia outlet, plain with grating including jointing with solvent cement complete all specified and directed. 118 S&F for PVC waste pipe for urinal/WHB with fitting etc 50 mm dia. 60mm long complete all specified and directed. 119 S & FPVC( SWR ) pipes 110mm dia single socketed , in any lengthwith rubber ring joints as rainwater,(eves gutter fitted in roof forcollecting of rain water).stack clamps out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stays to wall or roof ,welding etc complete all as specified and directed. 120 Dismantling of old ceilling boarding, wooden sacntling any description fixed in any position with nails complete all as specified and directed 121 Dismantling of Eves gutters , wooden sacntling any description fixed in any position with nails complete all as specified and directed. 122 Providing and fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum ) False ceiling tiles of size 595 x 595 mm of approved texture, design and patterns having moisture contents less than 2% humidity resistance of 99% NRCO.50 to .75 as pe IS8225:1987, Noncombustible as per BS 476 (Part 4)-1970 and light reflectance of 85% (Minimum) to be laid in true horizontal level suspended on interlocking metal T Grid of hot dipped galvanized iron section of 0.33 mm thick ( galvanised @ 120 gms per sqm including both sides ) comprising of main T runners of size 15 x 32 mm of length 3000mm, cross -T of size 15 x 32 mm of length 600mm to form grid module of size 600 x 600mm, suspened from ceiling using galvaized mild steel items ( galvanizing @ 80 grams per sqm) i..e 50mm long, 8mm outer diameter M-6 dash fastener 6mm dia fully threaded hanger rod upto 1000mm length and L-swhape level adjuster of size 85x25 x 2mm galvanised iron permieter wall angle of size 24 x 24 x 0.40mm of length 3000mm to be fixed on periphery wall/ partition with the help of plastic rawl plugs at 450 mm ceneter to centre and 50mm long dry wall wood screws. The kwork shall be carried out as per specifications, drawing and as per directions complete all as specified and directed. 123 Dismantling of AC sheets / Galvolume sheet / GI Sheet of corrugated or semicorrugated etc. sheets in roof coverings complete all as specified and directed. 124 Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. 125 M&L for MS framed structure roof trusses (framed), trussed, purlins, crane gantriesand fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats of Grade Fe 410 -W (Gde- E- 250) quality- A etc. complete all as specified and directed. 126 S&F Pre-painted galvalume aluminium zinc coating GI based profilesteel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa, hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) as in roof covering/ cladding to wall,including flashings , ridges, valley etc fixed with self tapping screws as specified 127 S&F Pre-painted galvalume aluminium zinc coating GI based plainsteel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa, hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. 128 S & F for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc. complete, drilled for fixing of steel sheeting or other covering doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, Fe 410-W (Gde-E-165) quality-A, etc complete all as specified and directed. 129 S & F Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, Thickness of sheet 1.60 mm, etc complete all as specified and directed. 130 M & L for preparation of newlyuntreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. 131 Material and labour Preparation new paintedwooden surfaces of any description over 10 cms width or girth not otherwise described and applying two coat of synthetic enamel paint complete all as specified and directed. 132 M&L for complete removal of existing treatment and preparation of old surfaces and applying two coat Acrylic emulsiondisptember with roller over applying minimum 1mm thick white wall care putty over prepared surface to achieve the surface even and smooth for painting complete all as specified and directed (Note:-Contractor shall furnish gaurantee of four year against service rendered) Note:- primer and emulsion paint shall be carred out through air less spray machine (Mechanical means) 133 M&L for preparation of newly plastered surfaces and applying two coat Acrylic emulsiondistember with roller over applying minimum 1mm thick white wall care putty over prepared surface to achieve the surface even and smooth for painting complete all as specified and directed (Note:-Contractor shall furnish gaurantee of four year against service rendered) Note:- primer and emulsion paint shall be carred out through air less spray machine (Mechanical means) 134 M&L for complete removal of existing treament and preparation of wall, washing, scrubbing down and stopping old treatment and painted surface of plastered / decorated surface and applyingtwo coat of Premium Acrylic smooth exterior paint and including priming coat of exterior primer and incl one coat of wall putty complete all a specified and as directed.(Note : painting will be done by brush / spray / roller of building upto the height) all as per directed by Engr -in-Charge) (Note :Rate shall be included for necessary scaffolding and safety measures where required at site ) 135 M&L for new/Old plastered / decorated surface and applyingtwo coat of Premium Acrylic smooth exterior paint and including priming coat of exterior primer and incl one coat of wall putty complete all a specified and as directed.(Note : painting will be done by brush / spray / roller of building upto the heightall as per directed by Engr -in-Charge) Note :Rate shall be included for necessary scaffolding and safety measures where required at site ) 136 M&L for HDPE Double Wall Corrugated pipe 150 mm internal bore laid in trenches & jointed as specified, and including demolition and breaking up drain pipes, complete all as specified and directed. 137 M&L for concrete bed to drain pipes 100mm dia bore using plain cement concrete (1:3:6) type C2(using 40mm graded stone aggregate) including packing under and haunching against the sides of pipes after they are laid and tested in complete all as specified and directed. 138 Taking down copper /aluminium point wiring (light, fan, bell,socketor power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc.Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces ofwalls, floors etc complete all as specified and directed. 139 Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface all as specified and directed at site. 140 Taking down carefully copper/aluminium Sub main wiring of any size fromsurface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. 141 Taking down existing geyser of any capacity after disconnecting all necessary electrical and water supply connections and deposit to MES store yard of AGE E/M No II complete all as specified and as directed. 142 Taking down existing single phase electric energy meter of any capacity after disconnecting all necessary electrical connections and deposit to MES store yard of AGE E/M No II complete all as specified and as directed. 143 M&L point wiring with 1.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC conduit (medium grade) concealed in wall / ceilingwith and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, conceiled on walls and fixed by neans of brass screws incl modular cover plates and cover frme any size/module,for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for the following complete for One light / fan /bell controlled by one, one way switch 5/6 Amps all as specified and as directed . 144 Description all as per ser item No. 143.00 above ,but for one 3 pin, 5/6 amps socket outlet point on independent boardcontrolled by one, one way 5/6 amps switch complete all as specified and directed. 145 Description all as per ser item No. 143.00 above , but for one 3 pin, 5/6 amps socket outlet point on same boardcontrolled by one, one way 5/6 amps switch complete all as specified and directed. 146 M&L point wiring with 2.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC conduit (medium grade) concealed in wall / ceilingwith and including 2.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, conceiled on walls and fixed by neans of brass screws incl modular cover plates and cover frme any size/module,for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one 15A socket point independentcompleteincl taking down of old unsv point wiringall as specified and directed. 147 S&F in replacement of Ceiling rosethree terminals surface bakelite type, AC, 50 HZ, 230V complete all as specified and directed. 148 S & F modular switch1 way 6 A , 1 modulecomplete all as specified and directed. 149 S & Fmodular socket 6 Amps 2/3 pin combined2 module complete all as specified and directed. 150 S & Fswitch modular type 16 A, 1 module complete all as specified and directed. 151 S & F socketmodular type multipurposes 6/16 A, 2 module complete all as specified and directed. 152 S & Fmodular bell push type 6 A ,1 module complete all as specified and directed. 153 S & Fbell multi music type AC 230 volts single pole complete all as specified and directed. 154 S&F surface /wall mounted LED batten fiitng slim channel type poly carbonate bodyT-8 tube light luminare with system efficiency 120 lumens per watts. High quality polycarbonate end cap in white finish and snap fitted to the housing completeall as specified and directed.integrated electronic driver complete with all connectedaccessories all as specified and directed. 155 M&L for Modular angular holder with LED Bulb 9 watts complete all as specified and as directed complete all as specified and directed. 156 S & FLED bldg security light fitting30wattmade up of pressure die cast aluminium housing with acylic cover as diffuser with IP-66 protection complete incl mounting pipe made of GI tubing 40 mm size 1M length bend into size with mounting brackets nut bolt and washers all as specified and directed. 157 S&F MCB DB SPN 8 way ,IP-43, IK 09, double door type with metal doorwith 200 Amps rated bus bar ,230 volts, 50 Hz complete all as specifed and directed. 158 Supply & FixMCB SPN 32 Amps current rating C series 10 KA breaking capacitycomplete all as specified and directed. 159 Supply & FixMCB SP 6 to 32 Amps current rating C series 10 KA breaking capacitycomplete all as specified and directed. 160 Supply and fixing TV socket outlet complete all as specified and as directed. 161 M & L sub main wiring with 2 runs of 06 sqmm main wire along with 1 run of 6 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC concealed / surface conduit (medium grade) wherever necessary with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good disturbed surfaces complete all as specified and directed.Note:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length. 162 Taking down existingexhaust fan/ceiling fan of any sweep after disconnecting necessary connection from ceiling rose to fan and deposit to MES store yardcomplete all as specified and as directed 163 S & Fexhaustfannon metalic single phase 230 volt of size 250 mmsweep with louverincl necessary altrationall as specified and as directed 164 S & Fexhaustfanmetalic single phase 230 volt of size 380 mmsweep with louverincl necessary altrationall as specified and as directed 165 S & F for ceiling fan, 230 Volts, 50Hz, 1200 mm sweep with down road, canopy, blades, BLDC motor etc and service value of the fan shall be greater than 6.1 as per BIS with necessary accessories and electrical connections from ceiling rose to fan teriminal includingwritting the MES Number with synthetic enamel paintcomplete all as specified and as directed. 166 Supply , fixingrigid non metallic PVC conduit fixed conceiled/on wall wherever necessary with all connectedaccessories20 mm dia forcable TV connectionscomplete all as specified and as directed 167 Supply, installation, commissioning and testing indoor type LT wall mounting Panel Board of minimum size 1.00 m (height) x 1.00 m (breath) x 0.30m (depth) factory made CPRI approved panel, weather, dust & vermin proof indoor, double door, front openable, including four compartment for fixing of 4 Nos single phase meter and MCB and providing glass view for reading of meter and providing rubber/ PVC gasket of suitable size all sides of door, withCopper strip busbar of size 25 x 5 mm wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrographic insulators with nuts & bolts at both ends= 04 Nos. , made out of 2.00 mm thick mild steel CRCA sheet with suitable size angle iron supporting frame including applying two coats of Powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces suitable for 3 phase 4 wire system 415/440 volts grade including complete internal wiring with 2.5 sqmm copper wire and connections of all outgoing / incoming existing cable of any size complete incl galvalume sheetfor protection of LT panel from rain/water all as directed 168 INCOMMING:-(a)MCCBIP 44 and IP 66/67 protection Ics =100% lcu, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 160 Amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links -01 No. (b) Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch – 01 Nos(c) DigitalAmmeter (0- 500)Amps, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch and CTs – 01 Nos(d) LED Neon indicator lamp (RYB) with holder,230/250 volts,AC -01 set (set of three) 169 OUTGOING :-(a) MCB SPN 40 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 04 Nos(b) Fixing only serviceable existing electric meter- 04 Nos 170 Replacement of Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground vertically to a depth not less than 2.25 meters deep below ground levelwith top edge of the plate not less than 1.5 Mtrs below normal ground level connect to galvanised earth lead wire of 4.0 sqmm size by means of bolts, nuts, check nuts and washers of galvanized iron or steel up to 7.5 meter length including connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40 mm thick RCC cover 1:2:4 mix with 6mm dia nominal reinforcement @ 150 mm c/c both ways etc completeall as shown in electrical plate No 5, connected to earthing test point complete including testing on completion all as specified. 171 supply and fix electric water heater storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 ltrs BEE 5 star rated complete with all accessories such as safey valve, thermostat, NRV, connecion pipe etc. 172 Supply only single phase energy meter AC 230 volt, 50 HZ, digital display from 10A to 30A all asspecified and directed by Engr-in-Charge 173 Supply and laying and testing Cable XPLE insulated, screened , PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy duty) 1100 volts grade with stranded aluminium conductor of16 sqmm4 core all as specified and as directed. 174 Excavation in trenches, n. exc. 1.5 m wide and n.exc 1.5 m in depth ;for foundation, etc or for shaft, well, cesspit, manhole, pier holes etc.n. exc. 10 sq m on plan and n. exc. 1.5 m in depth and getting out soft/loose soil all as specified and as directed. 175 M&L fine sand cushioningfor cable protection in layers incl punning all as specified and directed.Note : Punned down thickness shall only be measured. 176 Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm all as specified and as directed. 177 S & F tubes, light grade,galvanised, with all fitting of size 40 mm laid in trenches for cable protection all as specified and directed. 178 Returning, filling in, trenches including spreading, levelling watering and well ramming in layers not exceeding 25 cm Soft / loose soil all as specified and as directed. 179 Removing excavated soil to a distance not exc 50 m and depositing where directed at a level not exc1.5m above the starting point all as specified and as directed. 180 M&L for LED ceiling fitting 33 to 36 watts, 2 ft x 2 ft fittings suitable for aluminium grid ceiling, lumen out put ≥ 122 lumen/ watt,THD < 10% environmental friendly, new generation, aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source,incl inbuilt drivers suitable for Grid ceiling complete with atration of aluminium frame work wherever necessary during installation all as specified and directed.
Contract Date: Feb 20, 2026 Contract Value : 40.41 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Madhya Pradesh View Result →
TenderDetail
Loading tenders