View Bid Results For Dial Guage Tenders

We found 319 Bid Results related to dial guage tenders. You can find Contractor details who won dial guage tenders along with contract details in Bid awards announcements section.

Filters
Stage
249
54
16
Tender Publishing Platform
101
218
State / UT
31
59
33
32
25
19
17
17
14
12
12
11
7
6
5
5
5
5
5
5
4
3
3
3
3
2
2
1
1
1
1
1
Contract Value
102
86
96
33
Publish Date
1
1
0
0
0
Sector
24
63
45
37
29
29
25
18
15
10
10
8
7
4
4
3
2
2
2
1
1
1
1
1
1
Ownership
6
162
73
34
30
18
2
Within keyword
Active filters:
Showing 1–7 of 319 tenders matching your filters
1.
Agriculture #11440257 Technical Bid
Purchase Of Instrument Spares. , Purchase Of Instrument Spares. , Control Valve 4” (4440) (Pnuecon Valves Make) Only Diaphagram For Boiler Super Heater Control Vbalve. Sr. No- 210970776, Model 810/Pdo 055T, Size- 3” Characterstic-Linear’ Travel-38Mm, Supply Failure-Close , Guage Vaccum-760 (1968) (Micro/Forbes Marshell Make) Dial-6” Bottom Connection, ½” Bsp Thread, S.S 316 Bourdon Tube. , Jumbo Ceiling Rose (6240) (Electromed Make) Jumbo Display Flow Monitor, Input 4 To 20Ma, Power Supply 230 Vac With Tps-24 Vdc Raqnge 0 To 9999. Having Previous, Current And Flow Rate , Pressure Gauge Assorted Size (4665) (Forbes Marshall/Micro Make) Range 0 To 10 Kg/Cm2, Dial Size-6” Bottom Connection , ½” Bsp Thread, S.S Casing And Ss-316 Bourdon Tube , Rpm Indicator For Pt (6618) (Beacon Make) Range 0-10000, Cut Size- (92*92)Mm, Power Supply-230Vac, Signal Input-24 D.C. Output-4 To 20Ma , Air Filter Regultor (5000) (Festo/Jenetics Make) Fitting Size-1/4” Range (0 Ti 10Kg/Cm2) With Gauge , Air Filter Regulator (5000) (Festo/Jenetics Make) Air Filter Regulator & Lubricator Fitting Size-3/8”, Range (0 To 10Kg/Cm2) With Gauge And Lubricator. , Air Filter Regultor (5000) (Festo/Jenetics Make) Air Filter Regulator & Lubricator Fitting Size-3/8”, Range (0 To 10Kg/Cm2) With Gauge And Lubricator. , P U Connecter Lock Bolt (2051) (Jenetics/Festo Make) , P.V. Tube 8Mm (4974) (Jenetics/Festo Make) Pu Tube-Size 8Mm , Rubber Sheet For Pan Disc Charge Valve (2876) (Puri Make) Size Of Sheet- 654*490*25 , Seal Kit Complete Set For 12” Pan (5746) (Puri Make) For Kit For 12” Discharge Valve , C.S. Steam Valve ½” (4504) (Leader/Sant/Wj Make) For Steam/Impulse Lines Class-300 , Conector ½” (2032) (Jenetics/Airmax/Festo Make) For Pu Tube -8Mm And ½” Bsp Thread , Discoratry Valve (2031) (Airmax Make) Connection Size-1/4” , Draught Gauge (Vacuum) Dial Size-6” (Circular Type) Range- 1000/0 Mmwc, Fitting Size-1/2”(M) Bsp Bottom Side Make- Baumer/Micro (3389) (Forbes Marshall/Baumer/Micro Make) Draught Gauge-Dial Size-6” Range(0-1000 Mmwc), S.S Body And Bourdon Tube Ss-316, Bottom Connection ½” B.S.P , Guage Indecator Temprature 0-100 (3485) (Forbes Marshall Make) Temperature Gauge-Dial-6: Range (0-1500 C), S.S Body And Bourdon Tube Ss-316, Bottom Connection ½” Bsp Stem Length-300Mm , Guage Pressure 0-40 Kgs/600 Lbs (1965) (Forbes Marshall/Genernal Make)Dial Size-6”, S.S. Body And Bourdon Tube Ss-316, Bottom Conection ½” Bsp , Guage Pressure 0-40 Kgs/600 Lbs (Forbes Marshall/Genernal Make) Dial Size-10” Ss Body And Bourdon Tube Ss-316 Bottom Connection ½” Bsp , Kit 3” (1798) ( Puri Make) Model-Complete Set Of Pneumatic Cylinder Of Discharge Valve , Kit 8” (1797) (Puri Make) Model-Complete Set Of Pneumatic Cylinder Of Discharge Valve , Level Flow Transmiter (5385) (Honey Well Make) Range-0 To 10000 Mmwc, Make-Honey Well, Supply-24 Vdc, Signal Input-4-20 Ma Connection-1/4” Bsp , Ms Seamless Pipe ½” (3608) (Leader/Sant/Wj Make) For Steam/Impulse Line (Class-300) Of Transmitter , Pu Connector 6 Mm (367) (Jenetics/Festo Make) One Side Tube Connection-8Mm, Other Side Thread Connection Of ¼”Bsp , Pid Controller, 72*72 Mm, I/P-Rtd, O/P-Two Relay (No-Nc) (5010) (Honey Well Make) Input/Output-Universal, Cutsize-92*92, Make-Honey Well, Model-Dc-1040, Supply-220 Ac , Plc Card Inpur/Output For Boiler (3867) (Allen Bradley Make) Model-1762-If2/Of2 , Plc Card Input/Output For Boiler (3867) (Allen Bradely Make) Model-1762-If4/Of4 , Plc Controller (6180)(Allen Bradely Make) Model-Micrologix-830, Make Allen Bradely, With Modules , Pneumatic Positioner For Control Valve (4823) ( Aira/Ytc/Rotex Make) Type:- Rotary, Model: E/P-1000R, I/P Signal:- 4-20 Ma, Air Supply:- 0-7 Kg/ Sqcm, Standard Stroke-10-80Mm, Air Connection:- ¼” , Pneumatic Positioner For Control Valve (4823) (Ytc/Aira?Rotex Make) Type:- Linear, Model:- E/P-1000L, I/P Signal:- 4-20 Ma, Air Supply:- 0-7 Kg/Sqcm, Standard Stroke-10-80Mm, Air Connection:- ¼” , Positiner Relay (5933) Pilot Valve Realy For Aira Positioned , Pressure Gauge 2 Kg (4772) (Forbes Marshall/Genernal Make) Dial Size-6”, Ss Body And Bourdon Tube Ss-316, Bottom Connection ½” Bsp Gylicirine Filled. , Siganal Isolator I/P: 4-20 Ma, O/P: 4-20 Ma, Dual Output (3397) (Masibus Make) Model-9000U+Sc21, Input 4-20 Ma And Dual Out Put-4-2- Ma, With Tps. , Ss Reducer Socket 3/8”X1/2” (6545) Specially For Gauge Fitting Of ½” Bsp Thread , Temp. Indicutor J Type (4185) (Masibus Make) Inut/Output-Universal, Cutsize-48*92, Make-Masibus M-408, Supply-220 Ac , Thermocouple With Ss Thermowell (3005) (Alpha Make) K-Type, Duplex, Steam Length-300 Mm, Thickness-06 Mm, Bsp Thread, Connection Size-1/2” , Thermocouple With Ss Thermowell (3005) (Alpha Make) Pt-100, Duplex, Stem Length-300Mm, Thickness-6Mm, Bsp Thread, Connection Size-1/2”.
Contract Date: Ref. Documents Contract Value : Ref. Document
Cooperative No of Bidders 6
2.
Power #11436227 Technical Bid
Tender For Procurement Of Supply Of Pressure Gauges, Differential Pressure Gauges & Temperature Guages For 210 Mw Atps Mppgcl Chachai , (A) Bourden Type Pressure Gauges , (-)760 To 0 Mmhg , 0 To 1 Kg/Cm2 , -1 To 1.5 Kg/Cm2 , -1 To 6 Kg/Cm2 , 0 To 1 Bar , 0 To 1.6 Kg/Cm2 , 0 To 2 Kg/Cm2 , 0 To 4 Kg/Cm2 , 0 To 6 Kg/Cm2 , 0 To 6 Kg/Cm2 , 0 To 10 Kg/Cm2 , 0 To 16 Kg/Cm2 , 0 To 25 Kg/Cm2 , 0 To 40 Kg/Cm2 , 0 To 60 Kg/Cm2 , 0 To 250 Kg/Cm2 , 0 To 400 Kg/Cm2 , (B) Bourden Type Pressure Gauges , -1 To 0 Kg/Cm2 , 0 To 4 Kg/Cm2 , 0 To 6 Kg/Cm2 , 0 To 6 Kg/Cm2 , 0 To 16 Kg/Cm2 , 0 To 25 Kg/Cm2 , (C) Bourden Type Pressure Gauges , -1 To 1.5 Kg/Cm2 , 0 To 4 Kg/Cm2 , 0 To 16 Kg/Cm2 , 0 To 25 Kg/Cm2 , 0 To 40 Kg/Cm2 , 0 To 250 Kg/Cm2 , (D) Bourden Type Pressure Gauges , 0 To 7 Kg/Cm2 , 0 To 16 Kg/Cm2 , 0 To 16 Kg/Cm2 , 0 To 60 Kg/Cm2 , (E) Bourden Type Pressure Gauge , -760 To 0 Mmhg , -760 To +760 Mmhg , -1 To 0 Kg/Cm2 , 0 To 6 Kg/Cm2 , 0 To 10 Kg/Cm2 , 0 To 16 Kg/Cm2 , 0 To 16 Kg/Cm2 , 0 To 25 Kg/Cm2 , 0 To 40 Kg/Cm2 , (F) Bourden Type Pressure Gauges , 0 To 4 Kg/Cm2 , 0 To 6 Kg/Cm2 , 0 To 10 Kg/Cm2 , (G) Diaphragm Sensing Pressure Gauges , 0 To 400 Mmwc , 0 To 16 Kg/Cm2 , (A) Differential Pressure Gauges-Piston Type , 0 To 1.6 Bar , 0 To 1.6 Bar , 0 To 4 Bar , 0 To 7 Bar , (B) Differential Pressure Gauges-Diaphragm Type , 0 To 0.15 Kg/Cm2 Static Pressure: 60 Kg/Cm2 , 0 To 1.6 Bar Static Pressure : 100 Kg/Cm2 , 0 To 6000 Mmwc Static Pressure: 05 Kg/Cm2 , 0 To 0.4 Kg/Cm2 Static Pressure: 60 Kg/Cm2 , (A) Bimetallic Thermometer Range In Deg C (° C) , 0 To 100 , 0 To 100 , 0 To 100 , 0 To 100 , 0 To 100 , 0 To 150 , 0 To 150 , 0 To 150 , 0 To 150 , 0 To 150 , 0 To 200 , 0 To 200 , 0 To 200 , 0 To 200 , 0 To 200 , 0 To 400 , 0 To 400 , 0 To 400 , 0 To 400 , 0 To 400 , 0 To 600 , 0 To 600 , 0 To 600 , 0 To 600 , (B) Bimetallic Thermometer Range In Deg C (° C) , 0 To 100 , 0 To 100 , 0 To 100 , 0 To 100 , 0 To 100 , 0 To 200 , 0 To 200 , 0 To 200 , 0 To 200 , 0 To 200 , (C) Capillary Type Mercury In Steel Dial Thermometer Range In Deg C (° C) , 0 To 60 , 0 To 60 , 0 To 60 , 0 To 100 , 0 To 100 , 0 To 100 , 0 To 200 , 0 To 200 , 0 To 200 , 0 To 400 , 0 To 400 , 0 To 400 , 0 To 600 , 0 To 600 , 0 To 600 , (D) Capillary Type Mercury In Steel Dial Thermometer Range In Deg C (° C) , 0 To 60 , 0 To 60 , 0 To 60 , 0 To 100 , 0 To 100 , 0 To 100 , 0 To 200 , 0 To 200 , 0 To 200 , (E) Capillary Type Gas Filled Dial Thermometer Range In Deg C (° C) , 0 To 60 , 0 To 60 , 0 To 60 , 0 To 100 , 0 To 100 , 0 To 100 , 0 To 200 , 0 To 200 , 0 To 200 , 0 To 400 , 0 To 400 , 0 To 400 , 0 To 600 , 0 To 600 , 0 To 600
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Madhya Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 12.20 Lakh
Boards / Undertakings / PSU No of Bidders 1
Himachal Pradesh View Result →
4.
Public Administrative Department #11341498 Price Bid
Supply Of Needles And Syringes , Needles And Syringes , Disposable Needle Sterile Length 1/2 Guage – 25 , Disposable Needle Sterile Length 1/2 Guage – 26 , Disposable Needle Sterile Length 1 Guage – 23 , Disposable Needle Sterile Length 1 Guage – 24 , Disposable Needle -Sterile Size - 18, Length 1 1/2 , Disposable Needle -Sterile Size - 20, Length 1 1/2 , Disposable Needle Sterile Length 1 1/2 Guage – 21 , Disposable Needle Sterile Length 1 1/2 Guage – 22 , Suture Needle, Half Circle Triangular Nos. 2 To 20 (Cutting) , Insulated Needle For Use With Peripheral Nerve Stimulator 21G X 4 0.8 X 100 Mm , Insulated Needle For Use With Peripheral Nerve Stimulator 22G X 2X 50 Mm. , Insulated Needle For Use With Peripheral Nerve Stimulator23g X 35 Mm , Insulated Needle For Use With Peripheral Nerve Stimulator 24G X 1X 25 Mm. , Echogent Needles For Usg Guided Peripheral Nerve Blocks 20G /21G X 100 Mm , Echogent Needles For Usg Guided Peripheral Nerve Blocks 22G X 50 Mm , Epidural Needles 16 &18 Guage 7.5Cm To11cm (Disposable) , Epidural Needles (Long Length) 18G (More Than 100 Mm. Length) , Spinal Needles (Long Length) 22G X 43/4 0.7 X 120 Mm , Lp (Spinal) Needle Disposable, Sterile Pack Luer Lock Hub Transperant Hub Lumber Puncture Needle. Length Range, 8.5Cm To 10Cm, Small Bevel Indicator For Bevel Direction. Guage 23 , Lp (Spinal) Needle Disposable, Sterile Pack Luer Lockhub Transperant 8.5Cm To 10Cm, Small Bevel Indicator For Bevel Direction. Guage24 , Lp (Spinal) Needle Disposable, Sterile Pack Luer Lock Hub Transperant Hub Lumber Puncture Needle. Length Range, 8.5Cm To 10Cm, Small Bevel Indicator For Bevel Direction. Guage 25 , Lp (Spinal) Needle Disposable, Sterile Pack Luer Lockhub Transperant Hub Lumber Puncture Needle. Length Range, 8.5Cm To 10Cm, Small Bevel Indicator For Bevel Direction. Guage 26 , Sterile Disposable Lancet Size 18-24 (Plastic Lancet Needle Type) , Sterile Disposable Hypodermic Plastic Syringe 2Cc With Needle. , Sterile Disposable Hypodermic Plastic Syringe 5Cc, Cn With Needle , Sterile Disposable Hypodermic Plastic Syringe 10Cc, Sn.With Needle. , Sterile Disposable Hypodermic Plastic Syringe 20 Cc, Sn.With Needle, Size 20 G, 1 1/2 Long. , Sterile Disposable Hypodermic Plastic Syringe 2Cc With Leur Lock , Sterile Disposable Hypodermic Plastic Syringe 5Cc,Cn With Leur Lock , Sterile Disposable Hypodermic Plastic “Syringe 10Cc, Cn.” With Leur Lock , Sterile Disposable Hypodermic Plastic “Syringe 20 Cc, Cn.” With Leur Lock , Sterile Disposable Hypodermic Plastic “Syringe 50 Cc, Cn.” With Leur Lock , Sterile Disposable Hypodermic Plastic Syringe 2Cc Without Leur Lock , Sterile Disposable Hypodermic Plastic Syringe 5Cc,Cn Without Leur Lock , Sterile Disposable Hypodermic Plastic Syringe 10Cc, Sn. Without Leur Lock , Sterile Disposable Hypodermic Plastic Syringe 20 Cc, Sn.Without Leur Lock , Sterile Non-Reusable Auto Disable Mechanism Incorporated Syringes 2 M , Sterile Non-Reusable Auto Disable Mechanism Incorporated Syringes 5 Ml. , Tuberculin Syringes, Disposable Sterile, Sterile Pack, With/Withoutleur Lock, Hub 1Ml , Asepto Syringe 100 Ml Ofheavy Plastic Barrel And Rubber Bulb With Marking. , Bag Arm Rubber With Cover For B.P. Apparatus, Adult Size Velcro. Rubber Bag Size 13 X 23 Cms , Crescent Blade, Size-2.2 Mm, Type-Regular, Angle-45 Degrees, Bevel Type- Bevel Down, Colour-Green, Blade-Stainless Steel/Carbon Steel, Handle- Polycarbonate, Use- Disposable Single Use , Keratome, Size – 2.8 Mm, Type-Regular(Ophthalmic), Angle-45 Degrees, Bevel Type- Bevel Up (Pointed) Blade-Stainless Steel/Carbon Steel, Handle- Polycarbonate, Use- Disposable Single Use , Keratome, Size – 3.2 Mm, Type-Regular(Ophthalmic), Angle-45 Degrees, Bevel Type- Bevel Up (Pointed) Blade-Stainless Steel/Carbon Steel, Handle- Polycarbonate, Use- Disposable Single Use , Side Port Blade Type-Regular, Opthalmic Angle- 15 Degree, Blade-Stainless Steel/Carbon Steel, Handle- Polycarbonate, Use- Disposable Single Use , Mvr, Gauge – 20G Type-Regular(Ophthalmic), Blade-Stainless Steel Handle- Polycarbonate, Use- Single Disposable Use , Mvr, Gauge – 23G Type-Regular(Ophthalmic), Blade-Stainless Steel Handle- Polycarbonate, Use- Single Disposable Use , Threeway Plastic Connection Luer Lock And Side Connection For 1/8 I.D. Tubing. Plastic (Presterile) With Blockers / Stopper. , Venous Extension Tubing, Kink Resistancedisposable, Sterile Pack, Transparent Tubing, 15Cm One End Luer Lock Other End With Three Way. 15 Cm , Venous Extension Tubing, Kink Resistance Disposable, Sterile Pack, Transparent Tubing, 50Cm One End Luer Lock Other End With Three Way. 50 Cm , Venous Extension Tubing, Kink Resistance Disposable, Sterile Pack, Transparent Tubing, 100Cm One End Luer Lock Other End With Three Way. 100 Cm , Arterial Pressure Moni- Toring Tubing Disposable, Sterile Pack, Transparent Stiff & Nonkinkable Tubing 100Cm , Arterial Pressure Moni- Toring Tubing Disposable, Sterile Pack, Transparent Stiff & Nonkinkable Tubing 200Cm , Triple Lumen Central Venous Catheterisation Set For Children. Containing Catheter Size 5.00 To 5.5 Fr. 3 Lumens : 20G, 22G, Length - 8 To 10 Cm. Latex Free, Radio Opaque Catheter/ Extension Line Clamp, Introducer Needle 21G, J Tip Guide Wire, Tissue Dilator - 1 Syringe : Leur Lock / Leur Slip Suture Wing. Sterile, Non-Pyrogenic, Single Use, Peel To Open Pack, Transperant Cover On One Side , Triple Lumen Central Venous Catheterisation Set For Adults Containing Catheter Size 7 Fr. 3 Lumens : 16G, 18G, Length - 14 To 18 Cm. Latex Free, Radio Opaque Catheter, Clamp / Extension Line Clamp 18G Needle, J Tip Guide Wire, Introducer – 1 Tissue Dilator - 1 Syringe : Leur Lock / Leur Slip Suture Wing Sterile, Non-Pyrogenic, Single Use, Peel To Open Pack,Transperant Cover On One Side , Triple Lumen Catheter 7.5Fr With 14G Distal Lumen, Length-15Cm. Kit Contain 1 Teflon-Coated “J” Nitinol Guidewire Particularly Kink-Resistant With Guide- Advancer. 1 Dilator, 10Cm Long, 3 Injection Caps, 3 Clamps, 1 Supplementary Fixation Wing, 1 Scalpel, 1 Syringe 5 Ml, 1 Adaptor For Pressure Transducer, 1 Puncture Needle 18G, 70Mm Long With A Pre- Connected Valve To Aviod Air Embolism And Blood Loss, 1 18G Short Iv Cannula , Double Lumen Subclavian/Jugular Catheter Kit (Adult) Ptfe (Teflon) Cannula Curved Od 2.7/D 11.5Fr-12Fr/Chx5.3In.(3.8 Mm X 13.5 Cm) 6 Side Holes Silicon Tube S “Clamping Extension, Clamp”“Luer Lock” Y “Connector”With Protective Caps “Size 12.5, 15 With Guide Wire” “Introducer Needle, Dialator” , 3Fr Double Lumen Cvc Catheter With 60Mm Double-Lumen Polyurethane Central Venous Catheter Inserted By Seldinger Technique, Radio Opaque Material For Catheter, The User Should Be Able To Choose From 2 Type Of Introducer, I.E. Needle Or I.V. Cannula, Latex Free, The Central Venous Catheter Set Should Contain: 1 Double-Lumen Polyurethane 3Fr Catheter, 1 Short I.V. Cannula, 1 Introducer Needle, 1 Kink Resistant Guidewire With Soft Flexible Tip, Dilatorwith Cylindrical /Pencil Point Tip, 1 Secondary Fixation Wing, 2 Injection Caps, 1 Scalpel, 1 5 Ml Syringe , Peripherally Placed Radiopaque Central Catheter. Guage 14/16 (100%) (Needles Size/Catheter Size) Length -55Cm- 70Cm , Peripherally Placed Radiopaque Central Catheter. Guage 18/20 (100%) (Needles Size/Catheter Size) Length –30Cm- 45Cm , Fully Radiopaque Pur Catheter 16G For Femoral Artery Centimeter Marking From 5-15Cm, Winged Hub Forskin Fixation, Supple Distal Tip. Kit Should Contain 1 Pur Catheter With Xro Lines, 1 Puncture Needle, 1 J Guidewire With Wishbone-Type Guidewire Advancer, 1 Dilator , Radial/Femoral Arterial Pe Catheter With Antikinking Collar & Fixation Wings, Straight Guide Wire, Introducer Needle. Catherter Size G- 18, Length 10Cm , Radial/Femoral Arterial Pe Catheter 20G, 8Cm Puncture Needle Is Fitted With A Visualization Chamber Allowing To Confirm That The Vessel Punctured Is An Artery (Pulsatile Movement Of The Blood). The Needle Is Also Fitted With A Silicone Bloodless System Valveto Avoid Loss Of Blood During Vessel Puncture And A Funnel Hub To Facilitate The Insertion Of The Guidewire. , Peripherally Inserted Central Catheter With Peelable Cannula, Made Of Polyurethane, Non-Toxic, With Radio Opaque Line Throughout The Catheter With Marking Every Cm With Leurconnector At Proximal End Of Cathetereach Packed In Sterile Peel Able Pouch. Size - 28G, 1 Fr, 20 Cm , Peripherally Inserted Central Catheter With Peelable Cannula, Made Of Polyurethane, Non-Toxic, With Radio Opaque Line Throughout The Catheter With Marking Every Cm With Leurconnector At Proximal End Of Cathetereach Packed In Sterile Peel Able Pouch. Size - 24 G, 2 Fr, 30 Cm , Umbilical Catheter, Single Lumen, Made Of Non-Toxic, Medical Grade Pvc With Smooth Round Distal Tip With Radio Opaque Line Throughtout The Tube With Marking Every Cm With Luer Connector At Proximal End Of Catheter Each Packed In Sterile Peel Able Pouch. Size - 3.5 Fr, 30 Cm , Umbilical Catheter, Single Lumen, Made Of Non-Toxic, Medical Grade Pvc With Smooth Round Distal Tip With Radio Opaque Line Throughtout The Tube With Marking Every Cm With Luer Connector At Proximal End Of Cathetar Each Packed In Sterile Peel Able Pouch. Size - 4 Fr, 30 Cms , Umbilical Catheter, Single Lumen, Made Of Non-Toxic, Medical Grade Pvc With Smooth Round Distal Tip With Radio Opaque Line Throughtout The Tube With Marking Every Cm With Luer Connector At Proximal End Of Cathetar Each Packed In Sterile Peel Able Pouch. Size - 5 Fr, 40 Cm , Iv Cannula Disposable Sterile Pack, Fluro Ethylene Polypropylene/Or Ptfe/Biocompatible Material Peu Vialon Radiopaque Cathetar With Taper Tip Distance Between Bevel Of Stilette And Cannula Should Be Minimal Should Have Moderate Sized Flange Have Flanges With No Injection Ports. Guage - 16 Length - 45Mm To 75Mm , Iv Cannula Disposable Sterile Pack, Fluro Ethylene Polypropylene/Or Ptfe/Biocompatible Material Peu Vialon Radiopaque Cathetar With Taper Tip Distance Between Bevel Of Stilette And Cannula Should Be Minimal Should Have Moderate Sized Flange Have Flanges With No Injection Ports. Guage - 18 Length - 45Mm To 75Mm , Iv Cannula Disposable Sterile Pack, Fluro Ethylene Polypropylene/Ptfe/Biocompatible Material Radiopaque Cathetar With Taper Tip Distance Between Bevel Of Stilette And Cannula Should Be Minimal Should Have Moderate Sized Flange Have Flanges With No Injection Ports. Guage-20 Length- 25Mm To 50Mm , Iv Cannula Disposable Sterile Pack, Fluro Ethylene Polypropolene/ Ptfe/Biocompatible Material Radiopaque Cathetar With Taper Tip. Distance Between Bevel Of Stilette And Cannula Should Be Minimal Should Have Moderate Sized Flange Have Flanges With No Injection Ports. Guage - 22 Length - 25Mm To 50Mm , Iv Cannula Disposable Sterile Pack, Fluro Ethylene Polypropolene/ Ptfe/Biocompatible Material Radiopaque Cathetar With Taper Tip. Distance Between Bevel Of Stilette And Cannula Should Be Minimal Should Have Moderate Sized Flange Have Flanges With No Injection Ports. Guage – 24 Length - 18Mm To 30Mm , Safety Cannula:- With Smoothly Activating Passive Safety Mechanism. (Non Bulky) Without Change In Technique Of Insertion Along With Safety Needle Guard To Cover Authomatically Needles Sharp Bevelafter Wihtdrawal Of Needle. Needle Protecter For Cannual & Stillettee (Stillettee Should Be Stainless Less Steel And Not Needleprotector ) Canulation For The Complete Stillettee & Cannulation At Par Conventio- Nal Non Safety Cannula For Complete Length Of Biocomp- Atible & Radioopaque Materi- Al With Flash Back Chamber Threaded Stopper Alongwith Flanges & Injection Port With Cap & Internation Colour Cod- Ing Blister Packing For Each Iv Cannula Open Type Peel Medical Grade Paper Or Tyvek. (Stainless Steel Or Plastic Cap For Stillete Is Required) Gauge 16 , Safety Cannula:- With Smoothly Activating Passive Safety Mechanism. (Non Bulky) Without Change In Technique Of Insertion Along With Safety Needle Guard To Cover Authomatically Needles Sharp Bevelafter Wihtdrawal Of Needle. Needle Protecter For Cannual & Stillettee (Stillettee Should Be Stainless Less Steel And Not Needleprotector )Canulation For The Complete Stillettee & Cannulation At Par Conventional Non Safety Cannula For Complete Length Of Biocompatible & Radioopaque Material With Flash Back Chamber Threaded Stopper Alongwith Flanges & Injection Port With Cap & Internation Colour Coding Blister Packing For Each Iv Cannula Open Type Peel Medical Grade Paper Or Tyvek. (Stainless Steel Or Plastic Cap For Stillete Is Required) Gauge 18 , Safety Cannula:- With Smoothly Activating Passive Safety Mechanism. (Non Bulky) Without Change In Technique Of Insertion Along With Safety Needle Guard To Cover Authomatically Needles Sharp Bevelafter Wihtdrawal Of Needle. Needle Protecter For Cannual & Stillettee (Stillettee Should Be Stainless Less Steel And Not Needle Protector) Canulation For The Complete Stillettee & Cannulation At Par Conventio- Nal Non Safety Cannula For Complete Length Of Biocompatible & Radioopaque Material With Flash Back Chamber Threaded Stopper Alongwith Flanges & Injection Port With Cap & Internation Colour Coding Blister Packing For Each Iv Cannula Open Type Peel Medical Grade Paper Or Tyvek (Stainless Steel Or Plastic Cap For Stillete Is Required) . Gauge 20 , Safety Cannula:- With Smoothly Activating Passive Safety Mechanism. (Non Bulky) Without Change In Technique Of Insertion Along With Safety Needle Guard To Cover Authomatically Needles Sharp Bevelafter Wihtdrawal Of Needle. Needle Protecter For Cannual & Stillettee (Stillettee Should Be Stainless Steel And Not Needle Protector )Canulation For The Complete Stillettee & Cannulation At Par Conventional Non Safety Cannula For Complete Length Of Biocompatible & Radioopaque Material With Flash Back Chamber Threaded Stopper Alongwith Threaded Stopper Alongwith Flanges & Injection Port With Cap & Internation Colour Coding Blister Packing For Each Iv Cannula Open Type Peel Medical Grade Paper Or Tyvek. Gauge 22 , Straight Cannulas With Soft Tip For Vitrectomy Gauge -23G, Type-Retinal Cannula, Overall Length-50 Mm,Shaft Pattern-Straight, Tip Type Silicone Tube , Catheter Continuous Peripheral Nerve Block Catheter Set 18G X 43/8 (1.3 X 100Mm Or 110 Mm.) (Needle)20G (0.85 X 1000 Mm.) (Catheter) , Elastomeric Pumps With Flowrate 2 Ml / Hr.Total Volume 100 Ml Or Above , Elastomeric Pumps With Flowrate 5 Ml / Hr.Total Volume 300 Ml Or Above , Elastomeric Pumps With Multirate “1, 2, 3 Ml / Hr.”Total Valume 100 Ml Or Above , Elastomeric Pumps With Multirate “2, 3, 5 Ml / Hr.”Total Volume 300 Ml Or Above , Elastomeric Pumps With Multirate “5, 7, 12 Ml / Hr.”Total Volume 300 Ml Or Above , Vial Access Adapter: Closed Luer/Needle-Free Access System With Silicon Split Septum Or Mechanical Valves Straight For Unobstructed Fluid Path,Without Moving Parts And Transperent Housing. Vial Access Adapter Fixing With Vial At One End And Syringes Of All Sizes And Make At The Other End. , Closed Luer Access System With Silicon Split Septum, Straight, Unobstructed Fluid Path, No Moving Parts And Transparent Housing. Sizes: 15Cm Macro & Micro Bore Bi-Ext Set. , Closed Luer Access System With Silicon Split Septum, Straight, Unobstructed Fluid Path, No Moving Parts And Transparent Housing. Sizes: 15Cm Macro & Micro Bore Tri-Ext Set. , Closed Luer/Needle Free Split Access System With Silicon Septum Or Mechanical Valves,Straight For Unobstructed Fluid Path, Without Moving And Transparent Housing Individual Unit Fixing With I.V.Connuland Bivalve Connection At One End And Syringes Of All Types At Other End. , Surgical Blades, Nos.. 10,11,12,15,16,18,21,22,23 And 24 Presterile Wrapped With Antirust Paper In Aluminiumfoil, Should Be Fitting To Handle I.S.I.Mark. , Epidural Catheters With “Filter. 0.2Mm, Flat Sterile”Pack With Marking Clear Cathetar With Lateral Eyes “At The Tip, Luer Lock Twist”Connector Cathetar Guide/Introducer Catheter Size – 16G , Epidural Catheters With Filter. 0.2Mm, Flat Sterile Pack With Marking Clear Cathetar With Lateral Eyes At The Tip, Luer Lock Twist Connector Cathetar Guide/Introducer Guage 18 , Combined Spinal Epidural Needles Spinal Epidural Set Pencilpoint/Lancet Disposable Spinal Needle,Sterile Pack, 26G-27G/16G-18G Luer Lock & Transperant Hub, Tuohy Needle Length = 7.5 To 11Cms.Spinal Needle Protrusion By 11 - 14Mm With Epidural Catheter, Filter,Loss Of Resistancesyringe. , Complete Epidural Set (Disposable).Epidural Needle, Catheter Filter &Syringe, Tuohy Needle, Catheter With Guide & Lateral Eyes Marking Gradation At 50-150Mm At 10Mm & At 200Mm. Tuohy Needle Marking At 3Cms From Tip & Later On Every 1 Cm. Filter 0.2 Mm, Flat Loss Of Resistance Syringe 10Cc.Guage 16 Length75mm - 110Mm , Complete Epidural Set Needle, Catheter Filter &Syringe, Tuohy Needle,Catheter With Guide &Lateral Eyes Marking Gradation At 50-150Mm At 10Mm & At 200Mm.Tuohy Or Eqivalent Needle Marking At 3Cms From Tip & Later On Every 1 Cm. Filter 0.2 Mm,Flat Loss Of Resistance Syringe7 To 10Cc. Marking Guage 18, Length 75Mm - 110Mm , Complete Epidural Set (Disposable). Epidural Needle, Catheter (22G-40Cm) Filter &Syringe, Tuohy Or Eqivalent Needle,Catheter With Guide &Lateral Eyes Marking Gradation At 50-150Mm At 10Mm & At 200Mm.Tuohy Needle Marking At 3Cms From Tip & Later On Every 1 Cm. Filter 0.2 Mm, Flat Loss Of Resistance Syringe 7 To 10Cc. Marking Guage 19,Length 50Mm , Complete Epidural Set (Disposable). Epidural Needle, Catheter Filter & Syringe, Tuohy Or Eqivalent Needle,Catheter With Guide & Lateral Eyes Marking Gradation At 50-150Mm At 10Mm & At 200Mm.Tuohy Needle Marking At 3Cms From Tip & Later On Every 1 Cm. Filter 0.2 Mm,Flat Loss Of Resistance Syringe 7 To 10Cc. Marking Guage20, Length 50 Mm , Central Venous Catheter Size - 14/16 Cm , Disposable Sterile Hypodermic Needle With Safety Shield 24Gfor Single Use. N Size 24G X 1.5”. Made Up Of Stainless Steel With Puncture Protective Plastic Needle Cap. , Sterile Disposable Hypodermic Plastic Syringes: 100Ccc.N.With Leur Lock , Triple Lumen Central Venous Catheterization Set For Children Size =4. One 3 Lumen Catheter Set For Pediatric Central Venous Cannulation Having External Diameter Of 4 Fr And Length 60 Mm With Side Flanges For Fixation. Size Of Three Lumen Should Be 20G, 23G And 23G. Proximal And Middle Lumen Should Have Flow Rate Of Maximum Up To 6.5 Ml/Min And Priming Volume Of 0.11 Ml. Distal Lumen Should Have Flow Rate Of Maximum Up To 13 Ml/Min And Priming Volume Of 0.12 Ml It Should Come With A Introducer Sheath Having The Following Contents A. One 21 G Introducer Needle Length 38 Mm B. One 22 G Introducer Needle Length 25 Mm C. One Soft Tip Nitinol Guide Wire Of Diameter 0.46 Mm And Length 300 Mm D. One 5 Fr Dilator Length 60 Mm E. One 5 Ml Syringe F. Two Extra Flanges For Fixation G. One Scalpel # 11 Blade , Sterile Disposable Stainless Steel Skin Grafting Blade Compatible With Humby/Braithwaite Skin Grafting Handle (Ce Certification) , 4.5 Fr Double Lumen Cvc Catheter With 60Mm. Double-Lumen Polyurethane Central Venous Catheter Inserted By Seldinger Technique, Radio Opaque Material For Catheter, The User Should Be Able To Choose From 2 Type Of Introducer, I.E. Needle Or I.V. Cannula, Latex Free, The Central Venous Catheter Set Should Contain: 1 Double-Lumen Polyurethane 4.5 Fr Catheter, 1 Short I.V. Cannula, 1 Introducer Needle, 1 Kink Resistant Guidewire With Soft Flexible Tip, Dilator With Cylindrical /Pencil Point Tip, 1 Secondary Fixation Wing, 2 Injection Caps, 1 Scalpel, 1 5 Ml Syringe , 4 Fr Double Lumen Cvc Catheter With 60Mm. Double-Lumen Polyurethane Central Venous Catheter Inserted By Seldinger Technique, Radio Opaque Material For Catheter, The User Should Be Able To Choose From 2 Type Of Introducer, I.E. Needle Or I.V. Cannula, Latex Free, The Central Venous Catheter Set Should Contain: 1 Double-Lumen Polyurethane 4 Fr Catheter, 1 Short I.V. Cannula, 1 Introducer Needle, 1 Kink Resistant Guidewire With Soft Flexible Tip, Dilator With Cylindrical /Pencil Point Tip, 1 Secondary Fixation Wing, 2 Injection Caps, 1 Scalpel, 1 5 Ml Syringe , Clinical Thermometer For Measuring Body Temperature , Dial Flow- Sterilized Precision Flow Controller (Dial Type) Can Be Set From .5-250Ml/Hour. , Double Lumen Dialysis Femoral Catheter Size -16Cm, 11.5 F (Straight) , Double Lumen Dialysis Femoral Catheter Size - 20Cm, 11.5 F (Straight) , Dual Lumen Peripherally Inserted Central Catheter, Size - 5.0 F (1.80Mm Od) X 55 Cm, With Internal Stiffening Stylet/T Lock Assembly , Endoscopic Ultrasound Fine Needle Biopsy (Fnb) Device Needle, Size 19G , Endoscopic Ultrasound Fine Needle Biopsy (Fnb) Device Needle, Size 22G , Eye Patch With Drapes Size 100X70 Cm With Drain Pouch , Disposable Sterile Hypodermic Needle With Safety Shield 18Gfor Single Use. N Size 18G X 1.5” (1.2X38mm). Made Up Of Stainless Steel With Puncture Protective Plastic Needle Cap. , Disposable Sterile Hypodermic Needle With Safety Shield 23Gfor Single Use. N Size 23G X 1.5”. Made Up Of Stainless Steel With Puncture Protective Plastic Needle Cap. , Leaderflex Iv Catheter Polyurethane Peripherally Inserted Central Line With Polyurethane Catheter And Straight Guidewire With Flexible Tip. Size -22 G, 20 Cm , Triple Lumen Central Venous Catheterization Set For Children Size =3. One 3 Lumen Catheter Set For Pediatric Central Venous Cannulation Having External Diameter Of 3 Fr (1.05 Mm) And Length 60 Mm With Side Flanges For Fixation. Proximal And Distal Lumen Should Have Flow Rate Of Maximum Up To 4.4 Ml/Min And Priming Volume Of 0.09 Ml. It Should Come With A Introducer Sheath Having The Following Contents A. One 21 G Introducer Needle Length 38 Mm B. One 24 G Introducer Needle Length 19 Mm C. One Soft Tip Nitinol Guide Wire Of Diameter 0.3 Mm And Length 500 Mm D. One 3 Fr Dilator Length 50 Mm E. One 3 Fr Dilator Length 30 Mm F. One 5 Ml Syringe G. Two Extra Flanges For Fixation H. One Scalpel # 11 Blade , Triple Lumen Central Venous Catheterization Set For Children Size =4.5. One 3 Lumen Catheter Set For Pediatric Central Venous Cannulation Having External Diameter Of 4.5 Fr (1.5 Mm) And Length 60 Mm With Side Flanges For Fixation. Size Of Three Lumen Should Be 20G, 23G And 23G. Proximal And Middle Lumen Should Have Flow Rate Of Maximum Up To 6.5 Ml/Min And Priming Volume Of 0.11 Ml. Distal Lumen Should Have Flow Rate Of Maximum Up To 13 Ml/Min And Priming Volume Of 0.12 Ml It Should Come With A Introducer Sheath Having The Following Contents A. One 21 G Introducer Needle Length 38 Mm B. One 22 G Introducer Needle Length 25 Mm C. One Soft Tip Nitinol Guide Wire Of Diameter 0.46 Mm And Length 300 Mm D. One 5 Fr Dilator Length 60 Mm E. One 5 Ml Syringe F. Two Extra Flanges For Fixation G. One Scalpel # 11 Blade , Venous Extension Tubing With Volume Capacity Of 2Ml And Length Of 1 Meter For Infusion Of Iv Drugs With Three Way Attached On One Side , Ventriculoperitoneal Shunt Low Pressure With 2, 3 And 4 Ball Valve. Ventricular End With Tantalum Tip. Regulating Valve Contains Stainless Steel Sleeve And Balls And A Sapphire Ball. , Ventriculoperitoneal Shunt Medium Pressure With 2, 3 And 4 Ball Valve. Ventricular End With Tantalum Tip. Regulating Valve Contains Stainless Steel Sleeve And Balls And A Sapphire Ball. , Vitrectomy Cutter Turbovit 20 Gauge, 23 Gauge, 25 Gauge , Bone Marrow Aspiration Needle, Stainless Steel, Size - 11 And 12 Gauge , Echogenic Needle For Usg Size - 15Cm , Insulated Needles For Peripheral Nerve Stimulation Size - 5Cm , Insulated Needles For Peripheral Nerve Stimulation Size - 10Cm , Insulated Needles For Peripheral Nerve Stimulation Size - 15Cm , 26G Sterile Hypodermic Needle For Single Use. N Size 26G X 1.5” (0.45X30mm). Made Up Of Stainless Steel With Puncture Protective Plastic Needle Cap. , 27G Sterile Hypodermic Needle For Single Use. N Size 27G X 1.5” . Made Up Of Stainless Steel With Puncture Protective Plastic Needle Cap. , Acute Peritoneal Dialysis Catheter, Rigid Catheter, Marking From Tip 250 And 270Mm, Perforation 100Mm , 3 Fr Arterial Cannula. Sterile Single Use 3 Fr Arterial Cannula, Length 8 Cm, Diameter 0.9 Mm Permitting Flow Of Up Maximum Of 24Ml/Min, With Flanges For Fixation. The Cannula Should Come With Soft Tip Guide Wire Of Diameter 0.53 Mm And Length 200 Mm And Introducer Needle Diameter 0.9 Mm And Length 38 Mm. Eo Sterilized. , 4 Fr Arterial Cannula. Sterile Single Use 4 Fr Arterial Cannula, Length 10 Cm, Diameter 1.2 Mm Permitting Flow Of Up Maximum Of 24Ml/Min, With Flanges For Fixation. The Cannula Should Come With Soft Tip Guide Wire Of Diameter 0.71 Mm And Length 300 Mm And Introducer Needle Diameter 1.1 Mm And Length 52 Mm. Eo Sterilized. , 5 Fr Arterial Cannula. Sterile Single Use 5 Fr Arterial Cannula (16G), Length 15 Cm, Diameter 1.7 Mm Permitting Flow Of Up Maximum Of 67Ml/Min, With Flanges For Fixation. The Cannula Should Come With Soft Tip Guide Wire Of Diameter 0.97 Mm And Length 400 Mm, Introducer Needle Diameter (16 G) And Length 100 Mm And Plastic Dilator Of Size 17 G And Length 70 Mm. Eo Sterilized. , Av Fistula Needlesize - 16 Number , Av Fistula Needle Size - 18 Number , Capsular Tension Ring Size 10Mm, 12Mm , Doublej Open Ended Stent With French Size 3.5-10Cm , Doublej Open Ended Stent With French Size 3.5-12Cm , Doublej Open Ended Stent With French Size 3.5-14Cm , Doublej Open Ended Stent With French Size 3.5-16Cm , Doublej Open Ended Stent With French Size 3 -10Cm , Doublej Open Ended Stent With French Size 3 -12Cm , Doublej Open Ended Stent With French Size 3 -14Cm , Doublej Open Ended Stent With French Size 3 -16Cm , Doublej Open Ended Stent With French Size 4.5-20Cm , Doublej Open Ended Stent With French Size 4-16Cm , Doublej Open Ended Stent With French Size 4-18Cm , Double Cuffed Non-Rigid Capd Catheter Size - 42Cm , Sterile Eye Pads Size: 2-4 Inches (Diameter) , Fx 4 Dialyzer For Hemodialysis , Fx 8 Dialyzerfor Hemodialysis , Flexura Guidewire, Nitinol With Straight Tip, Size - 0.46 Mm (0.018 In.) Od X 50 Cm, Bendable , Insulin Administration Syringe U-40 Size 31G , Phaco Tips (For Zeiss Visalis 100) , Phaco Tips (For Oertli) , Safety Cannula Gauge 26 With Smoothly Activating Passive Safety Mechanism. (Non Bulky) Without Change In Technique Of Insertion Along With Safety Needle Guard To Cover Authomatically Needles Sharp Bevel After Wihtdrawal Of Needle. Needle Protecter For Cannual & Stillettee (Stillettee Should Be Stainless Less Steel And Not Needle Protector ) Canulation For The Complete Stillettee & Cannulation At Par Conventional Non Safety Cannula For Complete Length Of Biocompatible & Radioopaque Material With Flash Back Chamber Threaded Stopper Alongwith Flanges & Injection Port With Cap & Internation Colour Coding Blister Packing For Each Iv Cannula Open Type Peel Medical Grade Paper Or Tyvek.(Stainless Steel Or Plastic Cap For Stillete Is Required) , Spinal Manometer For Csf Pressure Measurement With Calibrated Scale , Tenckhoff Catheter For Peritoneal Dialysis Adult(Size - 2.6Mm Internal Diameter) , Tenckhoff Catheter For Peritoneal Dialysis : Paediatrics (Size - 15 Fr Outer Diameter) , Vitrectomy Cutter For Oertli , Trucut Biopsy Needle For Liver Biopsy With 9 Cm Length, 18 Gauge Size And 2 Cm Sample Size , Jamshidi Bone Marrow Biopsy Needle, Stainless Steel,Size: -11 And 12 Gauge
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 30
Maharashtra View Result →
6.
Educational and Research Institute #11318501 Technical Bid
Rate Contract For Supply Of Consumables/Non-Consumables For The Department Of Plastic Surgery , Consumables , Adhesive Hydrocellular Foam Dressing - Size: 12.5 Cm X 12.5 Cm , Adhesive Hydrocellular Foam Sacrum Dressing - Size: 17 Cm X 17 Cm , Adhesion Barrier Film Which Is Translucent And Hydrophilic Adhesion Barrier Made Of Sodium Hyaluronate And Carboxymethylcellulose - Size:5 Inx 6 In , Adhesion Barrier Film Which Is Translucent And Hydrophilic Adhesion Barrier Made Of Sodium Hyaluronate And Carboxymethylcellulose - Size:3 Inx5 In , Barrier Foam Dressing (Sterile) 10Cm X 10Cm , Barrier Gauze Dressing (Sterile) , Centella Asiatica, Silver Oxide And Silk Powder - 50Gm , Centella Asiatica, Silver Oxide And Silk Ointment - 25Gm , Centrifuge Tubes Polypropylene Cap (Sterile) - 15 Ml , Chlorhexidine Gauze Dressing Size 10 X 10Cm , Chlorhexidine Gauze Dressing Size 10 X 30Cm , Cockup Splint , Colloidal Silver Solution - Pre-Cleaning Solution Containing Colloidal Silver - 60 Ml , Compression Bandage , Cotton Crepe Bandage Size - 10Cm X 4M , Cotton Crepe Bandage Size - 15Cm X 4M , Fiber Glass Cast Tape For Limb Splint - Size: 7.5Cm , Fiber Glass Cast Tape For Limb Splint - Size: 10Cm , Fiber Glass Cast Tape For Limb Splint - Size: 15Cm , Finger Splint , G Bone(Modified Hydroxyapatite Granules And Blocks) , Gentamicin In Collagen Base Gel For Wound Healing - 30Gm , Hemostat To Stop Bleeding For Arterial Haemorrhages Comprised Of Agar And Bovine Factor Proteins (Iia, Viia, Xia And Xa) And Acts As A Catalyst In The Clot Formation Process - Pack Size 3Ml Vial , Ionic Silver Solution , Kaolin Impregnated X-Ray Detectable Hemostatic Dressing -Size:10 Cm X 10 Cm , Kaolin Impregnated Vaccum Packed Hemostatic Dressing -Size: 7.5 Cm X 3.7 M, X-Ray Detectable Strip , Kaolin Impregnated Ems Rolled Gauze Hemostatic Dressing -Size:7.5 Cm X 1.2 M , Low Adherent, Absorbent Wound Dressing - Size: 10Cm X 10Cm , Leur Lock Syringe (Disposable) - 2 Ml , Leur Lock Syringe (Disposable) - 5 Ml , Leur Lock Syringe (Disposable) - 20 Ml , Multi-Layered Design Incorporating Hydrocellular Foam With Hyper-Absorbent Lock Away Core Having Five Layers Comprising Of Masking Layer, Silicon Layer,And Polyurethane Breathable Top-Size: 12.9 X 12.9 Cm , Multi-Layered Design Incorporating Hydrocellular Foam With Hyper-Absorbent Lock Away Core Having Five Layers Comprising Of Masking Layer, Silicon Layer,And Polyurethane Breathable Top- Size: 15.4 X 15.4 Cm , Non Adhesive Hydrocellular Foam Dressing - Size: 10Cm X 10Cm , Non-Woven Island Wound Dressing (Non Woven Adhesive Sheet With Absorbent Pad) Size 10Cm X 8Cm , Non-Woven Island Wound Dressing (Non Woven Adhesive Sheet With Absorbent Pad) Size 10Cm X 20Cm , Non-Woven Island Wound Dressing (Non Woven Adhesive Sheet With Absorbent Pad) Size15cm X 8Cm , Orthopaedic Cast Padding-Size 10Cm X 3M , Orthopaedic Cast Padding-Size 15Cm X 3M , Oxidized Regenerated Cellulose, Bactericidal By Ph Action, Absorbable Topicalhemostat - Standard Size: 2 X 3. Approved By Ce , Oxidized Regenerated Cellulose, Bactericidal By Ph Action, Absorbable Topicalhemostat -Size 1 X 2 Fibrillar Form. Approved By Ce , Oxidized Regenerated Cellulose, Bactericidal By Ph Action, Absorbable Topicalhemostat -Size 1 X 1 Woven Form. Approved By Ce , Paraffin Gauze Dressingsize 10 X 10Cm , Paraffin Gauze Dressingsize 15 Cm X 2M , Polyester Wound Contact Layer With Central Cotton Absorbent Layer And Out Hydrophobic Non-Woven Layer. Low Adherent, Absorbent Wound Dressing -Size: 10 Cm X 10 Cm , Polyester Wound Contact Layer With Central Cotton Absorbent Layer And Out Hydrophobic Non-Woven Layer. Low Adherent, Absorbent Wound Dressing -Size: 10 Cm X 20 Cm , Polyester Wound Contact Layer With Central Cotton Absorbent Layer And Out Hydrophobic Non-Woven Layer. Low Adherent, Absorbent Wound Dressing-Size: 50 Cm X 7 Mtr Roll (Unsterile) , Pre-Cut Synthetic Splint System -Size: 10 X 40Cm , Pre-Cut Synthetic Splint System -Size: 12.5 X 76Cm , Pure Type I Bovine Collagen Particles , Rae Endotracheal Tubes (Oral Curved) (Pvc) Cuffed -Size 3.0, 3.5, 4.0, 4.5, 5.0, 5.5 (Set Of All Sizes) (50 Sets) , Rae Endotracheal Tubes (Oral Curved) (Pvc) Non Cuffed - Size 3.0, 3.5, 4.0, 4.5, 5.0, 5.5(Set Of All Sizes) (50 Sets) , Rae Endotracheal Tubes (Oral Curved) (Pvc) Cuffed -Size 6.0, 6.5, 7, 7.5 (Set Of All Sizes) (50 Sets) , Rae Endotracheal Tubes (Oral Curved) (Pvc) Noncuffed - Size 6.0, 6.5, 7, 7.5 (Set Of All Sizes) (50 Sets) , Recombiant Human Epidermal Growth Factor 150Ug/G Gel , Recombiant Human Epidermal Growth Factor 60Ug/G Gel , Silicone Gel In Tubes For Scar Treatment - 10Gm , Sterile Dehydrated Human Amnion Chorion And Polyhexamethylene Biguanide Powder (6Gm) , Sterile Dehydrated Human Umbilical Cord Derived Membrane Allograft-Size:5Cm X 3Cm , Sterile Dehydrated Human Amnion Chorion Membrane With Polyhexamethylene Biguanide- Size: 7Cm X 7Cm , Sterile Dehydrated Human Amnion Chorion Membrane With Polyhexamethylene Biguanide- Size:11M X 7Cm , Skin Marking Pen , Staple Remover , Temporary Biosynthetic Skin Dressingconstructed Of A Silicone Film Bonded To A Cross-Linked Dermal Collagen Coated Nylon Fabric-Size:13 X 13 Cm , Transparent Adhesive Dressing -Size: 60 X 45Cm , Type I Collagen Particles With Mupirocin Ip 2% W/W And Metronidazoleip 1% W/W , Universal Laser Eye Safety Goggles , Varicose Vein Stockings , Wd 40 Lubricant , Pla Reel 1Kg For 3D Printer Medical Grade , Arch Bar For Dental Reconstruction (German Silver/Stainless Steel) , External Fixator Set For Fingers , Hunters Rod (Silicon Rods) For Tendon Repairs , Silicon Block , Tendon Spacer , Nasalimplantdorsal , Chin Implant Adjustable , Cheek Implant (Zygomatic)Left , Cheek Implant (Zygomatic)Right , Round Loop Electrode For Radio Frequency Surgery - Fine Wire , Round Loop Electrode For Radio Frequency Surgery - Regular Wire , Triangularloop Electrode For Radio Frequency Surgery - Fine Wire , Triangular Loop Electrode For Radio Frequency Surgery - Regularwire , Needle Electrode For Radio Frequency Surgery - Fine Wire , Needle Electrode For Radio Frequency Surgery - Superfine Wire , Needle Electrode For Radio Frequency Surgery - Regular Wire , Bipolar Forceps Straight Compatible For Alan And Erbe Diathermy Machinesize 6- 0.2 Mm , Bipolar Forceps Straight Compatible For Alan And Erbe Diathermy Machinesize5 - 0.1 Mm , Bipolar Non-Stick Angled Forceps Compatible For Alan And Erbe Diathermy Machine Size 6 - 0.2 Mm , Bipolar Non-Stick Forceps 4 Fine Tip (1Mm) Compatible For Alan And Erbediathermy Machine , Bipolar Connecting Cable, Vio, Icc, Acc (2-Pin 22 Mm), 4 M For Bipolar Forceps With European Flat Plugcompatible For Alan And Erbe Diathermy , Cable For Bipolar Forceps Compatible For Alan And Erbe , Disposable Adult Patient Plate Compatible For Alan And Erbe Diathermypediatric , Disposable Handswitch Pencil For Monopolar Diathermy Compatible With Alan And Erbe Models , Disposable Neutral Plate - Adult , Disposable Neutral Plate - Pediatric , Ellman Company Radio Frequency Cable , Ellman Company Radio Frequency Plate , Spatula Electrode Compatible For Alan And Erbe Diathermy , Silicon Cord For Insulated Bipolar Forceps (Autoclavable) , Surgical Gloves: Polyurethane Inner Coating With Textured External Surface And Dark Coloured To Prevent Reflective Glare. Internal Surface Should Have Powder Free, Polymer Coated Siliconated. Size : 7.5 , Surgical Gloves: Polyurethane Inner Coating With Textured External Surface And Dark Coloured To Prevent Reflective Glare. Internal Surface Should Have Powder Free, Polymer Coated Siliconated. Size : 7 , Surgical Gloves: Polyurethane Inner Coating With Textured External Surface And Dark Coloured To Prevent Reflective Glare. Internal Surface Should Have Powder Free, Polymer Coated Siliconated. Size : 6.5 , Eutatic Mixture Of Local Anesthetic (Prilocain + Lignocain) Tubes , Beaver Needle Blade 1.5 Mm Cutting Edge, 3 Per Box , Bd Beaver Mini - Blade Knife- Straight, Sharp All Around 180° Cutting Surface, Double Level Blade , Beaver Mini-Blade Angled 60°, Sharp All Around 180° Cutting Surface, Double Level Blade , Multi Fire Vascular Clip Applicator For Liga Clip (5 Mm) , Cramer Wire - Small2 , Cramer Wire - Medium 3 , Cramer Wire - Large 4 , Cramer Wire- Extra Large 6 , Thermoplastic Perforated Sheet For Preparing Malleable And Strong Splint Size:45Cm X 60Cm X 5 Mm Thickness , Hydrojet Cannula , Dr. Lite Bulb Holder , Bulb 24 V 150 W , Ear Suction Canula (Luer Lock Fitting Blunt Point) With Connector16 G, 17 G& 18 G , Wound Protector / Retractor Device 2-4 Cms , Wound Protector / Retractor Device 2.5-6 Cms , Wound Protector / Retractor Device 5-9 Cms , Alar Retractor , Bone Marrow Aspiration Cannula 16 Gauge , Liposuction Tubings With Adaptor Suitable For Liposuction Model Infusa Plus , Paediatric Cuff For Zimmer Tourniquet Size 8 , Paediatric Cuff For Zimmer Tourniquet Size 12 , Ear Tip For Impedence Suitable For Gsi 38 Auto Tymp , Colorado Needles– 76Mm + 10Mm Tip Length , Colorado Needles– 76Mm + 10Mm Tip + 3Mm 45° Uninsulated Tip Length , Colorado Needles– 178Mm + 10Mm Tip + 3Mm 45° Uninsulated Tip Length , Colorado Micro Dissection Needles –3 Cm Straight (3/32 Sleeve) , Nano Crystaline Silver Gel 0.002% W/W , Hair Growth Serum - 60 Ml , Synthetic Biodegradable Temporizing Tri-Layered Open Cell Foam Matrix Made From Biodegradable Polyurethane. Converts Macro Wounds Into Organised Micro Wounds. Regenerates Neodermis And Neovascularization. Size: 5X5 Cm , Synthetic Biodegradable Temporizing Tri-Layered Open Cell Foam Matrix Made From Biodegradable Polyurethane. Converts Macro Wounds Into Organised Micro Wounds. Regenerates Neodermis And Neovascularization. Size: 10X10 Cm , Synthetic Biodegradable Temporizing Tri-Layered Open Cell Foam Matrix Made From Biodegradable Polyurethane. Converts Macro Wounds Into Organised Micro Wounds. Regenerates Neodermis And Neovascularization. Size: 10X20 Cm , Synthetic Biodegradable Temporizing Tri-Layered Open Cell Foam Matrix Made From Biodegradable Polyurethane. Converts Macro Wounds Into Organised Micro Wounds. Regenerates Neodermis And Neovascularization. Size: 20X40 Cm , Aqua Spray Aerosol ( With Bag-On-Valve Technology) For Bactericidal, Fungicidal Action As Gel, Ce Certified & Fda Approved Containing: Naocl (Sodium Hypochlorite) - 0.05%, Lithium Magnesium Sodium Silicate And Sodium Chloride And Purified Water 95.85%. Delivery Mechanism Is Continous Aerosol Creating & Emptying 100% Of Product From Container With No Contamination - 50 Gm , Aqua Spray Aerosol ( With Bag-On-Valve Technology) For Bactericidal, Fungicidal Action As Gel, Ce Certified & Fda Approved Containing: Naocl (Sodium Hypochlorite) - 0.05%, Lithium Magnesium Sodium Silicate And Sodium Chloride And Purified Water 95.85%. Delivery Mechanism Is Continous Aerosol Creating & Emptying 100% Of Product From Container With No Contamination - 100 Gm , Dressing Impregnated With Electrochemically Solutionreleasing Active Chlorine Released From Hypochlorous Acid 0.003% At 100 Ppm And Sodium Hypochlorite Solution With Neutral Ph, Non-Toxic, Human Skin Friendly Madefor Bactericidal, Fungicidal Action, Ce Certified & Fda Approved. Active - Hocl (0.003%) Inactive - Naocl + Nacl (­0.1%) Purified Water - 99.9% & Gauze - Size 10* 10 Cm , Electrochemical Solution Releasing Active Chlorine Released 100 Ppm Active - Hocl (0.003%) Inactive - Naocl + Nacl (­0.1%) Purified Water - 99.9% With Neutral Ph, Non-Toxic, Human Skin Friendly For Wound Care Cleansing & Irrigation - 100 Ml Spray , Electrochemical Solution Releasing Active Chlorine Released 100 Ppm Active - Hocl (0.003%) Inactive - Naocl + Nacl (­0.1%) Purified Water - 99.9% With Neutral Ph, Non-Toxic, Human Skin Friendly For Wound Care Cleansing & Irrigation - 250 Ml Spray , Electrochemical Solutionreleasing Active Chlorine Released 100 Ppm Active - Hocl (0.003%) Inactive - Naocl + Nacl (­0.1%) Purified Water - 99.9% With Neutral Ph, Non-Toxic, Human Skin Friendly For Wound Care Cleansing & Irrigation - 250 Ml Cap Bottle , Electrochemical Solution Releasing Active Chlorine Released 100 Ppm Active - Hocl (0.003%) Inactive - Naocl + Nacl (­0.1%) Purified Water - 99.9% With Neutral Ph, Non-Toxic, Human Skin Friendly For Wound Care Cleansing & Irrigation - 500 Ml Cap Bottle , Electrochemical Solutionreleasing Active Chlorine Released 100 Ppm Active - Hocl (0.003%) Inactive - Naocl + Nacl (­0.1%) Purified Water - 99.9% With Neutral Ph, Non-Toxic, Human Skin Friendly For Wound Care Cleansing & Irrigation - 1000Ml Cap Bottle , Electrochemical Solutionreleasing Active Chlorine Released 100 Ppm Active - Hocl (0.003%) Inactive - Naocl + Nacl (­0.1%) Purified Water - 99.9% With Neutral Ph, Non-Toxic, Human Skin Friendly For Wound Care Cleansing & Irrigation -500 Ml Irrigation Bag With Closed System (Self Collapsible & 2 Ports For Withdrawal One For Iv Set & 1 For Needle Withdrawal) , Electrochemical Solution Releasing Active Chlorine Released 100 Ppm Active - Hocl (0.003%) Inactive - Naocl + Nacl (­0.1%) Purified Water - 99.9% With Neutral Ph, Non-Toxic, Human Skin Friendly For Wound Care Cleansing & Irrigation - 1000 Ml Irrigation Bag With Closed System (Self Collapsible & 2 Ports For Withdrawal One For Iv Set & 1 For Needle Withdrawal) , Wound Care Gel Tube For Moistening And Debridement Of Acute And Chronic Wounds Such As Stage I-Iv Ulcers, Venous Stasis And Diabetic Ulcerations, Post-Surgery Wounds And Bed Soresfor Bactericidal, Fungicidal Action As Gel, Ce Certified & Fda Approved Containing: Naocl (Sodium Hypochlorite) - 0.05%, Lithium Magnesium Sodium Silicate-(4%) And Sodium Chloride And Purified Water 95.85% -15 Gm Gel Tube , Wound Care Gel Tube For Moistening And Debridement Of Acute And Chronic Wounds Such As Stage I-Iv Ulcers, Venous Stasis And Diabetic Ulcerations, Post-Surgery Wounds And Bed Sores For Bactericidal, Fungicidal Action As Gel, Ce Certified & Fda Approved Containing: Naocl (Sodium Hypochlorite) - 0.05%, Lithium Magnesium Sodium Silicate-(4%) And Sodium Chloride And Purified Water 95.85% -30 Gm Gel Tube , Wound Care Gel Tube For Moistening And Debridement Of Acute And Chronic Wounds Such As Stage I-Iv Ulcers, Venous Stasis And Diabetic Ulcerations, Post-Surgery Wounds And Bed Sores For Bactericidal, Fungicidal Action As Gel, Ce Certified & Fda Approved Containing: Naocl (Sodium Hypochlorite) - 0.05%, Lithium Magnesium Sodium Silicate-(4%) And Sodium Chloride And Purified Water 95.85%-50 Gm Gel Tube , Wound Care Gel Tube For Moistening And Debridement Of Acute And Chronic Wounds Such As Stage I-Iv Ulcers, Venous Stasis And Diabetic Ulcerations, Post-Surgery Wounds And Bed Soresfor Bactericidal, Fungicidal Action As Gel, Ce Certified & Fda Approved Containing: Naocl (Sodium Hypochlorite) - 0.05%, Lithium Magnesium Sodium Silicate-(4%) And Sodium Chloride And Purified Water 95.85%-100 Gm Gel Tube , Highly Absorbent Polyurethane Foam Dressing With Soft And Gentle Skin Friendly Silicone Adhesive For Moderate To Highly Exuding Wounds, Unique 3D Fit Foam Structure (Conforms To The Wound Bed, Absorbs Vertically, Retains Exudate) For Superior Absorption, Waterproof And Bacteria Proof Semi-Permeable Polyurethane Top Film. Size:7.5X7.5 Cm , Highly Absorbent Polyurethane Foam Dressing With Soft And Gentle Skin Friendly Silicone Adhesive For Moderate To Highly Exuding Wounds, Unique 3D Fit Foam Structure (Conforms To The Wound Bed, Absorbs Vertically, Retains Exudate) For Superior Absorption, Waterproof And Bacteria Proof Semi-Permeable Polyurethane Top Film. Size:10X10 Cm , Highly Absorbent Polyurethane Foam Dressing With Soft And Gentle Skin Friendly Silicone Adhesive For Moderate To Highly Exuding Wounds, Unique 3D Fit Foam Structure (Conforms To The Wound Bed, Absorbs Vertically, Retains Exudate) For Superior Absorption, Waterproof And Bacteria Proof Semi-Permeable Polyurethane Top Film. Size:12.5X12.5 Cm , Soft And Gentle Silicone Adhesive With Antimicrobial Properties, Highly Absorbent Foam Dressing With Polyurethane Top Layer Which Is Waterproof And Bacteria Proof Semi-Permeable. Profile Of Ionic Silver Upto 7 Days. Unique 3D Fit Foam Structure (Conforms To The Wound Bed, Absorbs Vertically, Retains Exudate) For Managing High To Moderate Exuding Infected Chronic Wounds. Size:7.5X7.5 Cm , Soft And Gentle Silicone Adhesive With Antimicrobial Properties, Highly Absorbent Foam Dressing With Polyurethane Top Layer Which Is Waterproof And Bacteria Proof Semi-Permeable. Profile Of Ionic Silver Upto 7 Days. Unique 3D Fit Foam Structure (Conforms To The Wound Bed, Absorbs Vertically, Retains Exudate) For Managing High To Moderate Exuding Infected Chronic Wounds. Size:10X10 Cm , Soft And Gentle Silicone Adhesive With Antimicrobial Properties, Highly Absorbent Foam Dressing With Polyurethane Top Layer Which Is Waterproof And Bacteria Proof Semi-Permeable. Profile Of Ionic Silver Upto 7 Days. Unique 3D Fit Foam Structure (Conforms To The Wound Bed, Absorbs Vertically, Retains Exudate) For Managing High To Moderate Exuding Infected Chronic Wounds. Size: 12.5X12.5 Cm , Thin, Ultra Flexible And Absorbent Polyurethane Foam Dressing With A Semi-Permeable, Bacteria- And Waterproof Top Film And A Soft Silicone Adhesive Layer. Unique 3D Foam Structure Absorbs The Exudate Vertically And Locks The Fluid Away Within Its Structure,Leaving The Wound Moist For Optimal Wound Healing Conditions. The Soft And Thin Foam Pad At Skin Level Makes It Comfortable To Wear And Is Suited For Users That Need Increased Mobility.Size:5X5 Cm , Thin, Ultra Flexible And Absorbent Polyurethane Foam Dressing With A Semi-Permeable, Bacteria- And Waterproof Top Film And A Soft Silicone Adhesive Layer. Unique 3D Foam Structure Absorbs The Exudate Vertically And Locks The Fluid Away Within Its Structure,Leaving The Wound Moist For Optimal Wound Healing Conditions. The Soft And Thin Foam Pad At Skin Level Makes It Comfortable To Wear And Is Suited For Users That Need Increased Mobility.Size:7.5X7.5 Cm , Thin, Ultra Flexible And Absorbent Polyurethane Foam Dressing With A Semi-Permeable, Bacteria- And Waterproof Top Film And A Soft Silicone Adhesive Layer. Unique 3D Foam Structure Absorbs The Exudate Vertically And Locks The Fluid Away Within Its Structure,Leaving The Wound Moist For Optimal Wound Healing Conditions. The Soft And Thin Foam Pad At Skin Level Makes It Comfortable To Wear And Is Suited For Users That Need Increased Mobility.Size:12.5X12.5Cm , Non Adhesive Antimicrobial, Highly Absorbent Foam Dressing With Polyurethane Top Layer Which Is Waterproof And Bacteriaproof Semi-Permeable. Profile Of Ionic Silver Upto 7 Days. Unique 3D Fit Foam Structure (Conforms To The Wound Bed, Absorbs Vertically, Retains Exudate) For Managing High To Moderate Exuding Infected Chronic Wounds. Size:10X20cm , Non Adhesive Antimicrobial, Highly Absorbent Foam Dressing With Polyurethane Top Layer Which Is Waterproof And Bacteriaproof Semi-Permeable. Profile Of Ionic Silver Upto 7 Days. Unique 3D Fit Foam Structure (Conforms To The Wound Bed, Absorbs Vertically, Retains Exudate) For Managing High To Moderate Exuding Infected Chronic Wounds. Size:20X20cm , Calcium Alginate Dressing With 65-75 % Guluronic Acid, Unique Structure Of Calcium Alginate And Cmc Molecules Intertwined In Strings Resulting In Local Vertical Absorption. For Managing Sloughy Wounds With Cavity.Size:3X44cm Ribbon Cavity , Calcium Alginate Dressing With A Unique Structure Of Calcium Alginate And Cmc Molecules Intertwined In Strings Resulting In Local Vertical Absorption And Gel Formation. 5.7%- 6.3% Sodium Zirconium Crystals Contains Silver Which Provide Broad And Continuous Antibacterial Profile For Upto 7 Days And Prevents Microbial Colonisation. For Managing Infected Sloughy Wounds With Cavity And Various Shapes, Sizes And Depths. Comes With Spin Finish To Prevent Fibre Shredding And Has Document Haemostatic Effect.Size:10X10 Cm , Calcium Alginate Dressing With A Unique Structure Of Calcium Alginate And Cmc Molecules Intertwined In Strings Resulting In Local Vertical Absorption And Gel Formation. 5.7%- 6.3% Sodium Zirconium Crystals Contains Silver Which Provide Broad And Continuous Antibacterial Profile For Upto 7 Days And Prevents Microbial Colonisation. For Managing Infected Sloughy Wounds With Cavity And Various Shapes, Sizes And Depths. Comes With Spin Finish To Prevent Fibre Shredding And Has Document Haemostatic Effect.Size:15X15cm , Hydrogel Consisting Of Natural Ingredients Such As Highly Purified Water, Sodium Carboxy-Methylcellulose And Calcium Alginate Without Any Additives. For Effective And Gentle Autolytic Debridement Of Necrotic Tissue, Dry And Sloughy Necrotic Wounds-15 Gm , Non-Invasive Skin Closure Strips With Sterile, Breathable, Non-Woven Rayon Backed Microporous Material Reinforced With Filaments For High Tensile Strength. Contains Hypoallergenic Adhesive To Reduce Skin Trauma. Dimension:12Mm X 100Mm (1/2 X 4 In)(Pack Of 50 Pcs) , Non-Invasive Skin Closure Strips With Sterile, Breathable, Non-Woven Rayon Backed Microporous Material Reinforced With Filaments For High Tensile Strength. Contains Hypoallergenic Adhesive To Reduce Skin Trauma. Dimension:6Mm X 100Mm (1/4 X 4 In) (Pack Of 50 Pcs) , Non-Invasive Skin Closure Strips With Sterile, Breathable, Non-Woven Rayon Backed Microporous Material Reinforced With Filaments For High Tensile Strength. Contains Hypoallergenic Adhesive To Reduce Skin Trauma. Dimension: 25Mm X 125Mm (1 X 5 In)(Pack Of 50 Pcs) , Sterile, Semipermeable, Transparent, Breathable, Water Proof, Bacterial And Viral Barrier Polyurethane Film (That Reduces Chance Of Infection) With Absorbent, Non-Adherent Pad (That Helps Reduce Trauma On Dressing Removal) And Latex Free Hypoallergenic Acrylic Adhesive That Is Gentle To Skin- Size: 9Cm X 10Cm (Pack Of 25 Pcs) , Sterile, Semipermeable, Transparent, Breathable, Water Proof, Bacterial And Viral Barrier Polyurethane Film (That Reduces Chance Of Infection) With Absorbent, Non-Adherent Pad (That Helps Reduce Trauma On Dressing Removal) And Latex Free Hypoallergenic Acrylic Adhesive That Is Gentle To Skin- Size:6Cm X 10Cm(Pack Of 50 Pcs) , Transparent, Semipermeable, Breathable, Water Proof, Bacterial And Viral Barrier, Synthetic Blood Penetration Resistance, Sterile, Polyurethane Film Peripheral Iv Dressing For Adults Reinforced With Soft Cloth Border And Notch. Non-Latex, Hypoallergenic Pattern Coated Acrylic Adhesive With 2 Large Extra Sterile Soft Cloth Tape Strips For Additional Securement And Complies With Iso-10993 Standards For Biocompatibility- Size: 6.5Cm X 7Cm (Pack Of 100 Pcs) , Silicone Gel Sheets For Scar Management - Size: 5 X5 Cm , Silicone Gel Sheets For Scar Management - Size: 10X10 Cm , Silicone Gel Sheets For Scar Management - Size: 20X20 Cm , Sterile Collagen Particles - 2.5Ml , Sterile Collagen Particles - 5Ml , Sterile Collagen Particles - 10Ml , Sterile Collagen Particles - 15Ml , Sterile Medicated Collagen Particles - 5Ml , Sterile Medicated Collagen Particles - 10 Ml , Sterile Medicated Collagen Particles - 15 Ml , Sterile Medicated Collagen Sheets In Dry Form Size: 10X10 Cm , Sterile Medicated Collagen Sheets In Dry Form Size: 10X20 Cm , Sterile Medicated Collagen Sheets In Dry Form Size: 15X30 Cm , Collagen Sheets Pure Type 1&3 Triple Helical In Wet Form - Size: 10X20 Cm , Collagen Sheets Pure Type 1&3 Triple Helical In Wet Form - Size: 15X30 Cm , Collagen Sheets Pure Type 1&3 Triple Helical In Dry Form - Size: 10X20cm , Collagen Sheets Pure Type 1&3 Triple Helical In Dry Form - Size: 15X30 Cm , Collagen Sheets Pure Type 1&3 Triple Helical In Meshed Form - Size: 10X20 Cm , Collagen Sheets Pure Type 1&3 Triple Helical In Meshed Form - Size: 15X30 Cm , Sterile Nano Oligosacchride Factor (Nosf) Foam Dressing With Border. Also Impreganted With Carboxy Methly Cellulose And Lipid Particles, Border - Size: 10 Cm X 10 Cm , Sterile Nano Oligosacchride Factor Foam (Nosf) Dressing With Border. Also Impreganted With Carboxy Methly Cellulose And Lipid Particles, Border- Size: 15 Cm X 20 Cm , Sterile Nano Oligosacchride Factor (Nosf) Contract Layer Dressing Impreganated Carboxy Methly Cellulose And Lipid Particles, Contact Layer - Size: 10 Cm X 10 Cm , Sterile Nano Oligosacchride Factor (Nosf) Contract Layer Dressing Impreganated Carboxy Methly Cellulose And Lipid Particles, Contact Layer - Size: 15 Cm X 20 Cm , Sterile Nano Oligosacchride Factor (Nosf) Micro Adhesive Dressingimpreganated Carboxy Methly Cellulose And Lipid Particles, Ma - Size: 10 Cm X 10 Cm , Sterile Nano Oligosacchride Factor (Nosf) Micro Adhesive Dressingimpreganated Carboxy Methly Cellulose And Lipid Particles, Ma - Size: 6 Cm X 6 Cm , Sterile Nano Oligosacchride Sucrose Factor ( Nosf) Healing Matrix, Micro Adhesive. Size 15Cmx 20Cm, European Ce Approved , Sterile Nano Oligosacchride Sucrose Factor ( Nosf) Healing Matrix, Micro Adhesive. Size 10Cmx 10Cm, European Ce Approved , Sterile Nano Oligosacchride Sucrose Factor ( Nosf) Healing Matrix, Micro Adhesive. Size 6Cmx 6Cm, European Ce Approved , Sterile Nano Oligosacchride Sucrose Factor ( Nosf) Healing Matrix, Contact Layer. Size 15 Cmx 20 Cm, European Ce Approved , Hyperoxygenated Glycerides Of Essestial Fatty Acid (Linoleic Acid 60%) With Tecopherol - 99% And Aniseed Pergume 1%, For Pressure Ulcer Prevention-Size 50 Ml , Hyperoxygenated Glycerides Of Essestial Fatty Acid (Linoleic Acid 60%) With Tecopherol - 99% And Aniseed Pergume 1%, For Pressure Ulcer Prevention-Size 20 Ml , Sterile Fish Collagen Type I Collagen Sponge -Size 10 X 10Cm , Occulusive Wound Dressing Non-Resorbable Which Contains Bio Cellulose 100%, Monolaurin 7%In A Sterile Pack-Size: 5 X 5 Cm , Occulusive Wound Dressing Non-Resorbable Which Contains Bio Cellulose 100%, Monolaurin 7%In A Sterile Pack-Size: 10 X 10 Cm , 2 Layer Polyurethane Ester Foam Dressings Size (11 X 8 X 1.8Cm) With Spiral Cut Sheet Use For Instillation (Not Irrigation), 1 Vac Instillation Trac Pad With 5 Lumen Tubing Set, 2 Sheets Of Vac Advanced Drape, 2 Packets Ofcavilon No Sting Barrier Film, 1 Disposable Ruler. With Cdsco And Fda & Ce Certified , 2 Layer Polyurethane Ester Foam Dressings Size (17 X 15 X 1.8Cm) With Spiral Cut Sheet Use For Instillation (Not Irrigation), 1 Vac Instillation Trac Pad Wit 5 Lumen Tubing Set, 2 Sheets Of Vac Advanced Drape, 2 Packets Ofcavilon No Sting Barrier Film,1 Disposable Ruler. With Cdsco And Fda & Ce Certified. , 2 Layer Polyurethane Ester Foam Dressings Size (25 X 15 X 1.6Cm) With Spiral Cut Sheet Use For Instillation (Not Irrigation), 1 Vac Instillation Trac Dual Pad With 5 Lumen Tubing Set, 5 Sheets Of Vac Advanced Drape, 4 Packets Ofcavilon No Sting Barrier Film,1 Disposable Ruler. With Cdsco And Fda & Ce Certified. , 3 Layer Foam Dressing Used For Instillation Therapy Size (25.6 X 15 X 0.8Cm, 25.6 X 15 X 1.6Cm, Contact Layer 25.6 X 15 X 0.8Cm W And 1Cm Circular Holes), 1 Vac Instillation Trac Pad With 5 Lumen Tubing Set, 4 Sheets Ofv.A.C. Advanced Drape, 4 Packets Ofcavilon No Sting Barrier Film,1 Disposable Ruler.With Cdsco And Fda & Ce Certified , 3 Layer Foam Dressings Used For Instillation Theraphy Size (25.6 X 15 X 0.8Cm, 25.6 X 15 X 1.6Cm, Contact Layer 25.6 X 15 X 0.8Cm And 1Cm Circular Holes), 1 Vac Instillation Trac Dual Pad With 5 Lumen Tubing Set, 6 Sheets Of Vac Advanced Drape,5 Packets Of Cavilon No Sting Barrier Film, 1 Disposable Ruler. With With Cdsco And Fda & Ce Certified , 500 Ml Canister (Sterile) Sensing Tracing Pad With 5 Lumen Tubing Set Prevent Leakage And Blockage, With Gel (Containing Sodium Polyacrylate To Covert Exudate Into Gel, So No Cross Contamination) And Clamp And Connector. With Cdsco And Fda & Ce Certified , 300 Ml Canister (Sterile) Sensing Trac Pad With 5 Lumen Tubing Prevent Leakage And Blockage, With Gel (Containing Sodium Polyacrylate To Covert Exudate Into Gel, So No Cross Contamination) Andclamp And Connector. With Cdsco And Fda & Ce Certified , 1000 Ml Canister (Sterile) With Instillation Trac Pad With 5 Lumen Tubing Set For Prevent Leakage And Blockage With Gel (Containing Sodium Polyacrylate To Covert Exudate Into Gel, So No Cross Contamination) And , Clamp And Connector. With Cdsco And Fda & Ce Certified , Foam Dressing (10 X 7.5 X 3.2Cm), 2 Sheets Of Vac Drape, 5 Lumen Trac Padtechonology With Connector, 1 Disposable Ruler, 1 Canister 300 Ml (Sterile) With 5 Lumentechonologytubing, Clamp And Connector With Cdsco And Fda & Ce Certified , Foam Dressing (18 X 12.5 X 3.2Cm), 2 Sheets Of Vac Drape, 5 Lumen Trac Padtechonology With Connector, 1 Disposable Ruler, 1 Canister 500 Ml (Sterile) With 5 Lumentechonologytubing, Clamp And Connectorwith Cdsco And Fda & Ce Certified , Foam Dressing (26 X 15 X 3.2Cm), 2 Sheets Of Vac Drape, 5 Lumen Trac Padtechonology With Connector, 1 Disposable Ruler, 1 Canister 1000 Ml (Sterile) With 5 Lumentechonologytubing, Clamp And Connector With Cdsco And Fda & Ce Certified , Foam Dressing (26 X 15 X 1.6Cm), 2 Sheets Of Vac Drape, 1 Instillation Trac Pad With 5 Lumen Tubing Set With Connector, 1 Disposable Ruler, 5 Lumen Trac Padtechonology With Connector, 1 Disposable Ruler, 1 Canister 300 Ml (Sterile) With 5 Lumentechonologytubing, Clamp And Connector With Cdsco And Fda & Ce Certified , Cassette With Instillation Tubing And 38Mm Spikeable Cap Adaptor. With Cdsco And Fda & Ce Certified , An Absorbent, Non Adherent Sterile Dressing With More Than 98% Silk Proteins. Nvtr Rate More Than 900 Kg/M2/24 Hours, Thickness Of Less Than 2Mm - Size: 5 X 5 Cm , An Absorbent, Non Adherent Sterile Dressing With More Than 98% Silk Proteins. Nvtr Rate More Than 900 Kg/M2/24 Hours, Thickness Of Less Than 2Mm - Size: 10 X 10 Cm , An Absorbent, Non Adherent Sterile Dressing With More Than 98% Silk Proteins. Nvtr Rate More Than 900 Kg/M2/24 Hours, Thickness Of Less Than 2Mm Size Dressing Impregnanted With Silver Ions And Sustained Release Upto 7 Days, Silver Content Of 1.5 Mg/Cm2 - Size: 5 X 5 Cm , An Absorbent, Non Adherent Sterile Dressing With More Than 98% Silk Proteins. Nvtr Rate More Than 900 Kg/M2/24 Hours, Thickness Of Less Than 2Mm Size Dressing Impregnanted With Silver Ions And Sustained Release Upto 7 Days, Silver Content Of 1.5 Mg/Cm2 - Size: 10 X 10 Cm , Anti Biofilm Wound Irrigation Solution With Betaine Surfactant And 0.1% Polyaminopropyl Biguanide (Polithexanide) 40 Ml , Anti Biofilm Wound Irrigation Solution With Betaine Surfactant And 0.1% Polyaminopropyl Biguanide (Polithexanide) 350 Ml , Anti Biofilm Wound Irrigation Rinsing Solution With Betaine Surfactant And 01% Polyaminopropyl Biguanide (Polithexanide) 1000 Ml , Anti Biofilm Wound Gel With Glycerol, Hydroxyethylcellulose, Betaine Surfactant And 0.1% Polyaminopropyl Biguanide (Polithexanide) 30 Mg , Anti Biofilm Wound Gel With Glycerol, Hydroxyethylcellulose, Betaine Surfactant And 0.1% Polyaminopropyl Biguanide (Polithexanide) 50 Gms , Anti Biofilm Wound Gel With Hydroxyethylcellulose, Glycerol, Betaine Surfactant And 0.1% Polyaminopropyl Biguanide (Polithexanide) 250 Gms , Lipido-Colloid Wound Contact Layer Impregnated With Silver Salts And Poly-Absorbent Fibres - Size: 6X6 Cm , Lipido-Colloid Wound Contact Layer Impregnated With Silver Salts And Poly-Absorbent Fibres - Size: 10X10 Cm , Lipido-Colloid Wound Contact Layer Impregnated With Silver Salts And Poly-Absorbent Fibres - Size: 15X20 Cm , Sterilenon-Occlusivewound Contact Layer Composed Of A Polyester Mesh Impregnatedwithhydrocolloid Particles (Cmc), Cohesion Polymers And Petroleum Jelly Usinglipido-Colloid Technology (Tlc) - Size: 10 X 10Cm , Sterilenon-Occlusivewound Contact Layer Composed Of A Polyester Mesh Impregnatedwithhydrocolloid Particles (Cmc), Cohesion Polymers And Petroleum Jelly Usinglipido-Colloid Technology (Tlc) - Size: 15 X 20 Cm , Sterilenon-Occlusivewound Contact Layer Composed Of A Polyester Mesh Impregnatedwithhydrocolloid Particles (Cmc), Cohesion Polymers And Petroleum Jelly Usinglipido-Colloid Technology (Tlc) - Size: 20 X 30 Cm , Sterilenon-Occlusive Woundcontact Layer Consists Of Silver Healing Matrix Made Of Polyester Mesh Impregnated With Hydrocolloid Particles (Cmc), Petroleum Jelly, Polymers And Silver Salts (Ag) Usinglipido- Colloid Technology (Tlc) - Size: 10 X 10 Cm , Sterilenon-Occlusive Woundcontact Layer Consists Of Silver Healing Matrix Made Of Polyester Mesh Impregnated With Hydrocolloid Particles (Cmc), Petroleum Jelly, Polymers And Silver Salts (Ag) Usinglipido-Colloid Technology (Tlc) - Size: 15 X 20 Cm , Sterile Non-Occulusive Wound Contact Layer Consists Of Silver Healing Matrix Made Of Polyester Mesh Impregnated With Hydrocolloid Particles (Cmc), Petroleum Jelly, Polymers And Silver Salts (Ag) Usinglipido-Colloid Technology (Tlc) - Size: 20 X 30 Cm , Sterile Wound Contact Layer Consists Of Silver Salts, Poly-Absorbent Fibres, Hydrocolloid Particles (Cmc), Petroleum Jelly And Polymers Usinglipido-Colloid Technology (Tlc) - Size: 6 Cm X 10Cm , Sterile Wound Contact Layer Consists Of Silver Salts, Poly-Absorbent Fibres, Hydrocolloid Particles (Cmc), Petroleum Jelly And Polymers Usinglipido-Colloid Technology (Tlc) - Size: 10 Cm X 10 Cm , Sterile Wound Contact Layer Consists Of Silver Salts, Poly-Absorbent Fibres, Hydrocolloid Particles (Cmc), Petroleum Jelly And Polymers Usinglipido-Colloid Technology (Tlc) - Size: 15 Cm X 20 Cm , Sterile Self -Adherent Tlc Matrix (Lipido Colloid Technology) Wound Contact Layer Combined Withabsorbent Polyurethane Foam Pad, A Super Absorbent Layer, A Vapour Permeable Waterproof Outer Film With Soft Silicone Adhesive Border On The Edges For Atraumatic Removal And Repositioning Of Dressing - Size: 8 X 8 Cm , Sterile Self -Adherenttlc Matrix (Lipido Colloid Technology) Wound Contact Layer Combined Withabsorbent Polyurethane Foam Pad, A Super Absorbent Layer, A Vapour Permeable Waterproof Outer Film With Soft Silicone Adhesive Border On The Edges For Atraumatic Removal And Repositioning Of Dressing - Size: 13 X 13 Cm , Sterile Self -Adherenttlc Matrix (Lipido Colloid Technology) Wound Contact Layer Combined Withabsorbent Polyurethane Foam Pad, A Super Absorbent Layer, A Vapour Permeable Waterproof Outer Film With Soft Silicone Adhesive Border On The Edges For Atraumatic Removal And Repositioning Of Dressing - Size: 10 X 25 Cm , Sterile Non-Woven Pad Composed Of Cohesive And Highly Absorbent Hydro-Desloughing Fibres (Polyacrylate), Combined Withtlc Matrix (Lipido Colloid Technology) Wound Contact Layer To Absorb, Trap And Drainage Of Slough From The Wounds. Sizes: 6X6 Cm , Sterile Non-Woven Pad Composed Of Cohesive And Highly Absorbent Hydro-Desloughing Fibres (Polyacrylate), Combined With Tlc Matrix (Lipido Colloid Technology) Wound Contact Layer To Absorb, Trap And Drainage Of Slough From The Wounds. Sizes: 10X10 Cm , Sterile Non-Woven Pad Composed Of Cohesive And Highly Absorbent Hydro-Desloughing Fibres (Polyacrylate), Combined With Tlc Matrix (Lipido Colloid Technology) Wound Contact Layer To Absorb, Trap And Drainage Of Slough From The Wounds. Sizes: 15X20 Cm , Hydrofiber Dressings With 1.2% W/W Impregnated Ionic Silver With Edta & Bec, Ce, Iso & Fda Approved - Size:5 X 5Cm , Hydrofiber Dressings With 1.2% W/W Impregnated Ionic Silver With Edta & Bec, Ce, Iso & Fda Approved - Size: 10 X 10 Cm , Hydrophilic Foam Dressing - Size: 10X10cm , Hydrophilic Foam Dressing - Size: 15X30cm , Hydrophilic Foam Silver Pad Dressing (Non-Adhesive And Antimicrobial) - Size:10X10cm , Hydrophilic Foam Silver Pad Dressing (Non-Adhesive And Antimicrobial) - Size: 15X30cm , Hydrocolloid Dressing With Absorbable Foam Padding (Extra-Thin Dressing) - Size: 10X10cm , Hydrocolloid Dressing With Absorbable Foam Padding- Size: 15X30 Cm , Sterile Human Amnion Chorion And Phmb Powder (3G ) , Sterile Polyhexamethylene Biguanide Coated Dehydrated Human Amnion Chorion Allograft - Size: 5X5 Cm , Sterile Polyhexamethylene Biguanide Coated Dehydrated Human Amnion Chorion Allograft - Size: 8X6 Cm , Sterile Polyhexamethylene Biguanide Coated Dehydrated Human Amnion Chorion Allograft- Size: 12X6 Cm , Film Dressing With Anti-Microbial Pad Using Dtac Technology-Size: 6X7 Cm , Film Dressing With Anti-Microbial Pad Using Dtac Technology-Size: 8X10 Cm , Film Dressing With Anti-Microbial Pad Using Dtac Technology-Size: 10X15 Cm , Film Dressing With Anti-Microbial Pad Using Dtac Technology-Size: 10X25 Cm , Film Dressing With Anti-Microbial Pad Using Dtac Technology-Size: 10X35 Cm , Topical Skin Adhesive For Wound Closure - 2-Octyl Cyanoacrylate High Viscosity Formulation For Small Incisions And Lacerations; 0.36 Ml Adhesive Volume , Semipermeable Waterproof Plastic Wound Dressing With Silver - Size: 5 Cm X 7 Cm , Semipermeable Waterproof Plastic Wound Dressing With Silver - Size: 15 Cm X 15 Cm , Semipermeable Adhesive Dressing Clear 6 X 7 Cm , Semipermeable Adhesive Dressingclear 8.5 X 10.5 Cm , Transparent Film Dressings Of A Thin Film Backing With Hypoallergenic, Latex-Free Adhesive - Size 6 Cm X 7 Cm , Transparentsemi Permeable Dressing Frame Style For Neonates Without Pad 10 Cm X 12 Cm Made Of Hypoallergenic, Latex-Free Adhesive , Transparentsemi Permeable Dressing Frame Style For Neonates Without Pad 6 Cm X 7 Cm Made Of Hypoallergenic, Latex-Free Adhesive , Adhesive Bandage Strips For Skin Closure Size 0.25X1.5 (Cost Per Strip Will Be Taken For Comparison Of Price) , Adhesive Bandage Strips For Skin Closure Size 0.25X4 (Cost Per Strip Will Be Taken For Comparison Of Price) , Adhesive Bandage Strips For Skin Closure Size 0.5X2 (Cost Per Strip Will Be Taken For Comparison Of Price) , Adhesive Bandage Strips For Skin Closure Size 0.5X4 (Cost Per Strip Will Be Taken For Comparison Of Price) , Reinforced Adhesive Skin Closures 0.125X3 (Cost Per Strip Will Be Taken For Comparison Of Price) , Reinforced Adhesive Skin Closures 1X5 (Cost Per Strip Will Be Taken For Comparison Of Price) , Silver Dressing With Pu Backing Layer And Absorbant Pad Dressing - Size: Dressing 5 X 7 Cm And Pad 2.5 X 4 Cm , Silver Dressing With Pu Backing Layer And Absorbant Pad Dressing - Size: Dressing 15 X 15 Cm And Pad 10 X 10Cm , Silver Dressing With Pu Backing Layer And Absorbant Pad Dressing - Size: Dressing 9 X 35Cm And Pad 5 X 30Cm , Super - Absorbant, Polyurethane Foam Dressing With Vertical Absorption With Silicone Wound Contact Layer - Size: 10 Cm X 10 Cm , Super - Absorbant, Polyurethane Foam Dressing With Vertical Absorption With Silicone Wound Contact Layer - Size: 10 Cm X 20 Cm , Super - Absorbant, Polyurethane Foam Dressing With Vertical Absorption With Silicone Wound Contact Layer - Size: 15 Cm X 15 Cm , Super - Absorbant, Polyurethane Foam Dressing With Vertical Absorption With Silicone Wound Contact Layer (Sacrum) - Size: 17.5 Cm X 17.5 Cm , Super - Absorbant, Polyurethane Foam Dressing With Vertical Absorption With Silicone Wound Contact Layer Heel 2D - Size: 16 Cm X 24 Cm , Super - Absorbant, Bacteria Binding Polyurethane Foam Dressing With Dialkyl Carbamoyl Chloride Layered - Size: 12.5 Cm X 12.5 Cm , Super - Absorbant, Bacteria Binding Polyurethane Foam Dressing With Dialkyl Carbamoyl Chloride Layered- Size: 15 Cm X 15 Cm , Super - Absorbant, Bacteria Binding Polyurethane Foam Dressing With Dialkyl Carbamoyl Chloride Layered - Size:17.5 Cm X 17.5 Cm , Antimicrobial Hydrocellular Foam Dressing. Ag Non Adhesive - Size: 10 Cm X 10 Cm , Antimicrobial Hydrocellular Foam Dressing. Ag Non Adhesive - Size: 12.5 Cm X 12.5 Cm , Antimicrobial Hydrocellular Foam Dressing. Ag Non Adhesive - Size: 15 Cm X 15 Cm , Antimicrobial Silver Dressing With Nano Crystallinewith Sustained Release Of Silver For 7 Days Having Polyster Mesh Size 15 Cm X 15 Cm , Antimicrobial Silver Dressing With Nano Crystallinewith Sustained Release Of Silver For 7 Days Having Polyster Mesh Size 10 Cm X 12.5 Cm , Hydrocellular Foam Dressing With Silicone Adhesive - Size: 10 Cm X 10 Cm , Hydrocellular Foam Dressing With Silicone Adhesive - Size: 10 Cm X 20 Cm , Hydrocellular Foam Sacrumdressing With Silicone Adhesive - Size: 16.8 Cm X 17.1 Cm , Self Adhesive Silicone Gel Sheet - Size: 12 Cm X 6 Cm , Super Oxidized Solution With Hypochlorous Acid 0.003% And Sodium Hypochlorite 0.004% With Neutral Ph - 100Ml , Super Oxidised Solution - Irrigation Solution With Hypochlorous Acid In Oxidized Water Base- 60Ml , Super Oxidized Gel With Hypochlorous Acid 0.008% And Sodium Hypochlorite 0.002%With Neutral Ph - 60Gm , Microbial Antiseptic Solution Poly Hexamethylene Biguanide - 100Ml , Hyaluronicacid Sodium Salt Gel - 50Gm , Phmb Impregnated Antimicrobial Dressing - Size 10X10 Cm And Absorbent Pad 5 X 5 Cm , Phmb Impregnated Antimicrobial Dressing - Size 10X25 Cm And Absorbent Pad 5 X 20 Cm , Antimicrobial Nano Crystaline Silver Dressing. Rayon Polyster Mesh Sandwiched Between Polyethylene Layers Binded With Ultrasonic Welds. Size 10Cm X 10 Cm , Antimicrobial Nano Crystaline Silver Dressing. Rayon Polyster Mesh Sandwiched Between Polyethylene Layers Binded With Ultrasonic Welds. Size 15Cm X 15 Cm , Antimicrobial Nano Crystaline Silver Dressing. Sustained Release Of Silver 70-100 Ppm For 3 Days Should Allow Fewer Dressing Changes. Size 20 Cm X 20 Cm , Antimicrobial Nano Crystaline Silver Dressing. Sustained Release Of Silver 70-100 Ppm For 3 Days Should Allow Fewer Dressing Changes. Size 15 Cm X 15 Cm , Tulle Gras Paraffin Gauze Dressing Medicated 10 Cm X 10 Cm , Tulle Gras Paraffin Gauze Dressing Chlorhexidine Medicated 15 Cm X 30 Cm , Partially-Hydratedamorphous Hydrogel15gms , Amorphous Hydrogel Wound Dressing Antimicrobial Antibacterial Gel With Nano Silver - 15 Gms , Amorphous Hydrogel Wound Dressing Antimicrobial Antibacterialgel With Nano Silver - 50 Gms , Cmc Sodium Wound Dressing Gel-15 Gms , Transparent Polyurethane Surgical Drape Size 40 Cm X 42 Cm , Transparent Polyurethane Surgical Drape Size 30 Cm X 28 Cm , Waterproof & Bacteria Proof Post-Operative Film Dressing For Post Surgical Wounds & Minor Trauma Wounds Size 9.5 Cm X 8.5 Cm , Waterproof & Bacteria Proof Post-Operative Film Dressing For Post Surgical Wounds & Minor Trauma Wounds Size 15.5 Cm X 8.5 Cm , Transparent Film Roll. Thin Waterproof Polyurethane Film With High Mvtr With Low Allergy Water Based Acrylic Adhesive That Minimizes The Risk Of Skin Irritation Or Sensitivity, Film Is Highly Conformable And Extensible To Fit To Awkward Dressing Areas, Unique And Novel Roll Format Enables Rapid And Economical Use- Size:10 Cm X 10 Cm , Stainless Steel Suture 5-0/ 6-0 (Pack Of 12 Nos) , Synthetic Absorbable Sutures (Polyglycolic Acid/Polyglactin 910) -4/0 With 16Mm 5/8 Circle Cutting 45Cm (Pack Of 12 Foils) , Absorbent, Low Adherent Post Operative Dressing With Adhesive Coated Backing Material. - Size: 15 Cm X 8 Cm , Absorbent, Low Adherent Post Operative Dressing With Adhesive Coated Backing Material. - Size: 25 Cm X 10 Cm , Negative Pressure Wound Therapy Dressing. Subatmospheric Pressure Therapy Pu Foam - Size: 10X 10 X 2.8 Cm And 0.4Ltr Fluid Cask With Gel , Negative Pressure Wound Therapy Dressing. Subatmospheric Pressure Therapy Pu Foam - Size: 10X 15 X 2.8 Cm And 0.4Ltr Fluid Cask With Gel , Negative Pressure Wound Therapy Dressing. Subatmospheric Pressure Therapy Pu Foam - Size: 23.8 X 15.8X 2.8 Cm And 1 Ltr Fluid Cask With Gel , Dressing Material For Negative Pressure Wound Therapy Dressing Kit Consister - 500Ml Capacity Large , Dressing Material For Negative Pressure Wound Therapy Dressing Kit Consister - 500Ml Capacity Medium , Dressing Material For Negative Pressure Wound Therapy Dressing Kit Consister - 500Ml Capacity Small , Vinyl Acetate Copolymer 250Ml/1000Mldisposable Exudate Collectionpouch Individually Sealed In Sterile Package, Used With 250Ml / 1000Ml Reusable Containers. The Securely Mounted Pouch Tube Consists Of 3 Active Ventilation Lumens And 1 Exdate Lumen. It Should Have Chemical Filter To Trap Moisture, Odour, To Monitor The Amount Of Infections Fluid Being Removed, To Solidify Infectious Fluid And Should Have Minimum Capacity , Advance Wound Care Dressing, Non-Woven Highly Absorbent, Hemostatic Gelling Fiber Composed Of 100% Natural Biopolymer With A Net Positive Charge, Gamma Sterilized And Moisture Proof Packing, Manufactured In India, Gmp And Iso 13485 Certified. Size: 10X10 Cm , Advance Wound Care Dressing, Non-Woven Highly Absorbent, Hemostatic Gelling Fiber Composed Of 100% Natural Biopolymer With A Net Positive Charge, Gamma Sterilized And Moisture Proof Packing, Manufactured In India, Gmp And Iso 13485 Certified. Size: 15 X 15 Cm , Microsutures Polymide Black Coloured 11/0 Needle Thickness 70-100 Microns Length 3.5 - 5Mm3.8 Circle135 Degreesmicro Taper Point(Pack Of 12 Nos) , Microsutures Polymide Black Coloured10/0 Needle Thickness 70- 100 Microns Length 3.5 - 5Mm3.8 Circle 135 Degrees Micro Taper Point (Pack Of 12 Nos) , Microsutures Polymide Black Coloured9/0 Needle Thickness 100-150 Microns Length 3.5 - 5Mm3.8 Circle 135 Degrees Micro Taper Point (Pack Of 12 Nos) , Microsutures Polymide Black Coloured8/0 Needle Thickness 100-150 Microns Length4 - 7 Mm3.8 Circle 135 Degrees Micro Taper Point (Pack Of 12 Nos) , Hydrophilic Non-Woven Gauze Roll, Impregnated With A Naturally Occurring Inorganic Mineral - Kaolin, Along With A Unique Direct Pressure Adhesive Bandage Packaged In A Foil Pouch For Aseptic Removal - 7.6 Cm X 3.7 Cm , Hemostatic Dressing For External Application, 4 Ply Non-Woven Gauze - Size:4 X 4 Inches, Impregnated With A Naturally Occurring Inorganic Mineral - Kaolin, With A X-Ray Detectable Strip Packaged In A Foil Pouch For Aseptic Removal.Fda & Ce Approved , Patient Pre-Operative Skin Preparation Solution 25 Ml In One-Step Sterile Applicator Container For Single Use With 2% Chg And 70% Ipa With Orange Tint Color For Visibility. Fda Approved. , Patient Pre-Operative Skin Preparation Solution 10 Ml In 0Ne-Step Sterile Applicator Container For Single Use With 2% Chg And 70% Ipa With Orange Tint Color For Visibility. Fda Approved. , Thromboembolism Stocking , Acellular Dermal Matrix, Flexible, More Collagen, Stronger, Non- Chemical Cross Linked, Conformable At Complicated Anatomic Areas, Easy To Use, Handle And Apply. Size (74X52x1mm), Usfda And Dcgi Approved , Acellular Dermal Matrix, Flexible, More Collagen, Stronger, Non- Chemical Cross Linked, Conformable At Complicated Anatomic Areas, Easy To Use, Handle And Apply. Size (74X52x2mm), Usfda And Dcgi Approved , Acellular Dermalmatrix, Flexible, More Collagen, Stronger, Non- Chemical Cross Linked, Conformable At Complicated Anatomic Areas, Easy To Use, Handle And Apply. Size (148X105x1mm) Usfda And Dcgi Approved , Acellular Dermalmatrix, Flexible, More Collagen, Stronger, Non- Chemical Cross Linked, Conformable At Complicated Anatomic Areas, Easy To Use, Handle And Apply. Size (52X37x1mm) , Usfda And Dcgi Approved , Acellular Dermalmatrix, Flexible, More Collagen, Stronger, Non- Chemical Cross Linked, Conformable At Complicated Anatomic Areas, Easy To Use, Handle And Apply. Size (52X37x2mm), Usfda And Dcgi Approved , Acellular Dermalmatrix, Fenestrated, Non- Chemical Cross Linked, For High Exudating Wounds, Easy To Use, Handle And Apply. Size (74X52x1mm), Usfda And Dcgi Approved , Acellular Dermalmatrix, Flexible, More Collagen, Stronger, Non- Chemical Cross Linked, For High Exudating Wounds, Easy To Use, Handle And Apply. Size (148X105x2mm), Usfda And Dcgi Approved , Acellular Dermalmatrix, Fenestrated, Non- Chemical Cross Linked, For High Exudating Wounds, Easy To Use, Handle And Apply. Size (74X52x3mm), Usfda And Dcgi Approved , Acellular Dermal Matrix, Fenestrated, Non- Chemical Cross Linked, For High Exudating Wounds, Easy To Use, Handle And Apply. Size (52X37x1mm) , Usfda And Dcgi Approved , Acellular Dermalmatrix, Fenestrated, Non- Chemical Cross Linked, For High Exudating Wounds, Easy To Use, Handle And Apply. Size (52X37x3mm), Usfda And Dcgi Approved , Acellular Dermalmatrix, Single Step Procedure For Dermal Regeneration, Non- Chemical Cross Linked, Room Tempreture Storage, Size(74X52x1mm), Usfda And Dcgi Approved , Acellular Dermalmatrix, Single Step Procedure For Dermal Regeneration, Non- Chemical Cross Linked, Room Tempreture Storage, Size(52X37x1mm), Usfda And Dcgi Approved , Dermal Regeneration Template Bilayer (Bovine Collagen And Glycosaminoglycan (Chondroitin-6- Sulfate) And Silicone Layer - Size: 2In X 2In (5Cmx5cm) , Dermal Regeneration Template Bilayer (Bovine Collagen And Glycosaminoglycan (Chondroitin-6- Sulfate) And Silicone Layer - Size: 4In X 5In (10Cmx12.5Cm) , Dermal Regeneration Template Bilayer (Bovine Collagen And Glycosaminoglycan (Chondroitin-6- Sulfate) And Silicone Layer - Size: 4In X 10In (10Cmx25cm) , Meshed Dermal Regeneration Template Bilayer - Mesh (Bovine Collagen And Glycosaminoglycan (Chondroitin-6-Sulfate) And Silicone Layer - Size: 2In X 2In (5Cmx5cm) , Meshed Dermal Regeneration Template Bilayer - Mesh (Bovine Collagen And Glycosaminoglycan (Chondroitin-6-Sulfate) And Silicone Layer - Size: 4In X 5In (10Cmx12.5Cm) , Meshed Dermal Regeneration Template Bilayer - Mesh (Bovine Collagen And Glycosaminoglycan (Chondroitin-6-Sulfate) And Silicone Layer - Size: 4In X 10In (10Cmx25cm) , 2 Octyl Cyanoacrylate Adhesive In A Special Aluminium Collapsible Tube Pack ( 2 X 1.75Gm) And Applicator Having Self Puncturing Cap And A Soft Elastomeric Tip (Soft Bristles) For Ease Of Application Along With Curved Mesh Design Of Length 30 Cm Skin Closure System , 2 Octyl Cyanoacrylate Adhesive Having 1 Ml (One Ml)In A Special Aluminium Collapsible Tube Pack And Applicator Having Self Puncturing Cap And A Soft Elastomeric Tip , Silk Protein Based Sterile Surgical Wound Dressing Sheet For Chronic & Acute Wounds. The Silkdressing Should Also Have Below Parameters : 1)Silk Content Should Be More Than 75% 2)Thickness Of Silk Should Be More Than 1.2 Mm 3)Moisturevapor Transmission Rate Should Be 800 G/M2/24Hr Size - 10X10 Cm , Silk Protein Based Sterile Surgical Wound Dressing Sheet For Chronic & Acute Wounds. The Silkdressing Should Also Have Below Parameters : 1)Silk Content Should Be More Than 75% 2)Thickness Of Silk Should Be More Than 1.2 Mm 3)Moisturevapor Transmission Rate Should Be 800 G/M2/24Hr Size - 15X15 Cm , Silk Protein Based Sterile Surgical Wound Dressing Sheet For Infected Wounds. The Silkdressing Should Also Have Below Parameters : 1)Silk Content Should Be More Than 75% 2)Thickness Of Silk Should Be More Than 1.2 Mm 3)Moisturevapor Transmission Rateshould Be 800 G/M2/24Hr. 4) 7 Days Of Silver Releaseand Silver Content Of 1.5Mg/Cm2size - 5X5 Cm , Silk Protein Based Sterile Surgical Wound Dressing Sheet For Infected Wounds. The Silkdressing Should Also Have Below Parameters : 1)Silk Content Should Be More Than 75% 2)Thickness Of Silk Should Be More Than 1.2 Mm 3)Moisturevapor Transmission Rateshould Be 800 G/M2/24Hr. 4) 7 Days Of Silver Releaseand Silver Content Of 1.5Mg/Cm2 Size - 20X20 Cm , Silk Protein Based Sterile Surgical Wound Dressing Sheet For Infected Wounds. The Silkdressing Should Also Have Below Parameters : 1)Silk Content Should Be More Than 75% 2)Thickness Of Silk Should Be More Than 1.2 Mm 3)Moisturevapor Transmission Rateshould Be 800 G/M2/24Hr. 4) 7 Days Of Silver Releaseand Silver Content Of 1.5Mg/Cm2 Size - 30X30 Cm , Hydrophobic Bacteria And Fungi Binding Wound Dressing Pad,Consists Of A Dacc Coated Wound Contact Layer Combined With An Absorbent Core-Size: 10X10 Cm , Hydrophobic Bacteria And Fungi Binding Wound Dressing Pad,Consists Of A Dacc Coated Wound Contact Layer Combined With An Absorbent Core-Size: 10X20 Cm , Non-Absorbent Bacteria And Fungi Binding Wound Contact Layer,Consists Of A Dacc-Coated 8 Folded Wound Contact Layer. Size: 7X10 Cm , Bacteria And Fungi Binding Absorbent Polyurethane Foam With Super-Absorbent Stripes Which Absorb And Lock Additional Wound Exudate With Wound Contact Surface Consists Of A Dacccoated Wound Contact Layer With A Silicon Fixation Border And Water-Repellent Outer Film, Yet Permeable To Oxygen And Vapour. Size: 10X10 Cm , Bacteria And Fungi Binding Absorbent Polyurethane Foam With Super-Absorbent Stripes Which Absorb And Lock Additional Wound Exudate With Wound Contact Surface Consists Of Adacccoated Wound Contact Layer With A Silicon Fixation Border And Water-Repellent Outer Film, Yet Permeable To Oxygen And Vapour. Size: 12.5X12.5 Cm , Bacteria And Fungi Binding Absorbent Polyurethane Foam With Super-Absorbent Stripes Which Absorb And Lock Additional Wound Exudate With Wound Contact Surfaceconsists Of Adacccoated Wound Contact Layer With A Silicon Fixation Border And Water-Repellent Outer Film, Yet Permeable To Oxygen And Vapour. Size: 15X15 Cm , Silicone Coated Absorbent Polyurethane Foam Dressing That Contains Super-Absorbent Stripes Which Absorb And Lock Wound Exudate. With Perforated Silicone Wound Contact Layer With A Silicon Fixation Border And Water-Repellent Outer Film, Yet Permeable To Oxygen And Vapour And If Necessary The Dressing Can Be Cut To Size.Size: 7Cmx9cm Oval , Silicone Coated Absorbent Polyurethane Foam Dressing That Contains Super-Absorbent Stripes Which Absorb And Lock Wound Exudate. With Perforated Silicone Wound Contact Layer With A Silicon Fixation Border And Water-Repellent Outer Film, Yet Permeable To Oxygen And Vapour And If Necessary The Dressing Can Be Cut To Size.Size: 12.5Cmx12.5Cm , Silicone Coated Absorbent Polyurethane Foam Dressing That Contains Super-Absorbent Stripes Which Absorb And Lock Wound Exudate. With Perforated Silicone Wound Contact Layer And Water-Repellent Outer Film, Yet Permeable To Oxygen And Vapour And If Necessary The Dressing Can Be Cut To Size.Size: 10Cmx10cm , Silicone Coated Absorbent Polyurethane Foam Dressing That Contains Super-Absorbent Stripes Which Absorb And Lock Wound Exudate. With Perforated Silicone Wound Contact Layer And Water-Repellent Outer Film, Yet Permeable To Oxygen And Vapour And If Necessary The Dressing Can Be Cut To Size.Size: 10Cmx20cm , Anatomically Heel Shaped Silicone Coated Absorbent Polyurethane Foam Dressing That Contains Super-Absorbent Stripes Which Absorb And Lock Wound Exudate. With Perforated Silicone Wound Contact Layer And Water-Repellent Outer Film, Yet Permeable To Oxygen And Vapour And If Necessary The Dressing Can Be Cut To Size. Size: 16Cmx24cm , Anatomically Heel Shaped Silicone Coated Absorbent Polyurethane Foam Dressing That Contains Super-Absorbent Stripes Which Absorb And Lock Wound Exudate. With Perforated Silicone Wound Contact Layer And Water-Repellent Outer Film, Yet Permeable To Oxygen And Vapour And If Necessary The Dressing Can Be Cut To Size And With Two Fixation Strips Are Placed In The Peel Pouch Meant For Fixation Of The Dressing To The Heel. , Knee High Open Toe Gradient Compression Stockings With A Decreasing Pressure Gradient From Distal To Proximal With Effective Moisture Wicking Technology Contains 40% Elastane And 60% Polyamide Of Innovative Nilit Aquarius Fibers Wick Away Moisture And Give A Feeling Of Comfort All Day Long - Extra Large , Knee High Open Toe Gradient Compression Stockings With A Decreasing Pressure Gradient From Distal To Proximal With Effective Moisture Wicking Technology Contains 40% Elastane And 60% Polyamide Of Innovative Nilit Aquarius Fibers Wick Away Moisture And Give A Feeling Of Comfort All Day Long - Large , Knee High Open Toe Gradient Compression Stockings With A Decreasing Pressure Gradient From Distal To Proximal With Effective Moisture Wicking Technology Contains 40% Elastane And 60% Polyamide Of Innovative Nilit Aquarius Fibers Wick Away Moisture And Give A Feeling Of Comfort All Day Long - Medium , Thigh High Open Toegradient Compression Stockings With A Decreasing Pressure Gradient From Distal To Proximal With Effective Moisture Wicking Technology Contains 40% Elastane And 60% Polyamide Of Innovative Nilit Aquarius Fibers Wick Away Moisture And Give A Feeling Of Comfort All Day Long With An Silicon Impregrantedthigh Band- Extra Large , Thigh High Open Toegradient Compression Stockings With A Decreasing Pressure Gradient From Distal To Proximal With Effective Moisture Wicking Technology Contains 40% Elastane And 60% Polyamide Of Innovative Nilit Aquarius Fibers Wick Away Moisture And Give A Feeling Of Comfort All Day Long With An Silicon Impregrantedthigh Band- Large , Thigh High Open Toegradient Compression Stockings With A Decreasing Pressure Gradient From Distal To Proximal With Effective Moisture Wicking Technology Contains 40% Elastane And 60% Polyamide Of Innovative Nilit Aquarius Fibers Wick Away Moisture And Give A Feeling Of Comfort All Day Long With An Silicon Impregrantedthigh Band- Medium , Compression System With Two Components, A Medical Stockingwith 76% Polyamide And A Compression Liner With 79% Polyamide And 5% Silk, Provide A Nominal Compression Of 40 Mmhg* At The Ankle With Decreasing Pressure Gradient From Distal To Proximal -Large , Compression System With Two Components, A Medical Stockingwith 76% Polyamide And A Compression Liner With 79% Polyamide And 5% Silk, Provide A Nominal Compression Of 40 Mmhg* At The Ankle With Decreasing Pressure Gradient From Distal To Proximal - Extra Large , Compression System With Two Components, A Medical Stockingwith 76% Polyamide And A Compression Liner With 79% Polyamide And 5% Silk, Provide A Nominal Compression Of 40 Mmhg* At The Ankle With Decreasing Pressure Gradient From Distal To Proximal - Medium , Leg Wrap Withshort Stretch Adjustable Compression Band System With 50% Overlapping Wraps Contains 82% Polyamide And 18% Elastane Along With Non-Compressive Linerscontains 96% Polyamide And 4% Elastane , Foot Wrap Withshort Stretch Adjustable Compression Band System With 50% Overlapping Wraps Contains 82% Polyamide And 18% Elastanealong With Non-Compressive Linerscontains 96% Polyamide And 4% Elastane , Knee Wrap Withshort Stretch Adjustable Compression Band System With 50% Overlapping Wraps Contains 82% Polyamide And 18% Elastane With Non-Compressive Linerscontains 96% Polyamide And 4% Elastane , Multipurpose Tube Holder For Foley Catheters , Polyurethane Foam Mattress 23 Density 72X36 Mm (In Rolls) , Microcuff Endotracheal Tube (Oral, Curved) Forpediatrics -Size 4 Mm , Laparotomy Drape , Craniotomy Drape , Surgeon Gown (Large Size) Which Is A Fully Wrap Around Variety And Can Be Tied In Front, With Water, Alcohol Resistance. Outer Layer Spun Bound Repellant Layer With Inner Two Layers With Antibacterial Property (Melt Blown), And Innermost Layer For Fabric Strength (Spun Bound) Soft Elastic Wrist Cuff. Adjustable Neck Line Needed. Low Linting. Sample Absolutely Required. Must Meet Or Exceed Enl3795 Standards Or Else Will Not Be Considered. Quote Separately For Tape Covered Double-Stitched Seam Type Gown As Well As The One With Ultrasound Bonded Seam , Endotracheal Tube With Polyurethane Cuff (Size: 5.0, 5.5, 6.0,6.5) (Pack Of 10) , Endotracheal Tube With Polyurethane Cuff (Size: 2.5, 4.5)(Pack Of 10) , Oxygen Mask Without Nebulizer - Adult , Oxygen Mask Without Nebulizer - Pediatrics , Dial Flow (I.V. Infusion Dial Regulator) Flow Rates From 20 To 250Ml / Hr; Stable Flow Rates Upto 72 Hrs; Reliable And Accurate Flow Control; Dial With Ridges For Easy Grippingand Adjustment , Nrbm Face Mask With Reservoir Bag - Adult , Bacterial Filter , Oral Airway , T-Piece Connector , Catheter Mount , Ventilator Circuit , Burette Set , Microscope Cover - Medium Compatible With Leica M525 Mc1 , Microscope Cover - Medium Compatible With Carl Zeiss , Glycolic Acid Peels For Scar Treatment 20% - 100Ml , Glycolic Acid Peels For Scar Treatment 35% - 100Ml , Glycolic Acid Peels For Scar Treatment 50% - 100Ml , Glycolic Acid Peels For Scar Treatment 75% - 100Ml , Tissue Expanders With Injection Port And Stainless Steel Connector Of Various Sizes And Shapes - Round 150 Cc , Tissue Expanders With Injection Port And Stainless Steel Connector Of Various Sizes And Shapes -Round 210 Cc , Tissue Expanders With Injection Port And Stainless Steel Connector Of Various Sizes And Shapes - Round 310 Cc , Tissue Expanders With Injection Port And Stainless Steel Connector Of Various Sizes And Shapes - Round 400Cc , Tissue Expanders With Injection Port And Stainless Steel Connector Of Various Sizes And Shapes - Rectangular 170 Cc , Tissue Expanders With Injection Port And Stainless Steel Connector Of Various Sizes And Shapes - Rectangular 250 Cc , Tissue Expanders With Injection Port And Stainless Steel Connector Of Various Sizes And Shapes - Rectangular 260 Cc , Tissue Expanders With Injection Port And Stainless Steel Connector Of Various Sizes And Shapes - Rectangular 300 Cc , Tissue Expanders With Injection Port And Stainless Steel Connector Of Various Sizes And Shapes - Rectangular 350 Cc , Tissue Expanders With Injection Port And Stainless Steel Connector Of Various Sizes And Shapes - Elliptical 150Cc , Tissue Expanders With Injection Port And Stainless Steel Connector Of Various Sizes And Shapes - Elliptical 250 Cc , Tissue Expanders With Injection Port And Stainless Steel Connector Of Various Sizes And Shapes - Elliptical 125 Cc , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 1.5 X 2H With Gap , Titaniumlow Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 1.5 X 4H With Gap , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 1.5 X 4H Without Gap , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 1.5 X 6H With Gap , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 1.5 X 6H Without Gap , Titanium Low Profile Plates (Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 1.5 X 4H- L Right , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 1.5 X 4H- L Left , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 1.5 X 5H- L Lt & Rt , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Orbital Plate Short Bar 0.6 Mm Thicknessscrew 1.5 Mm4/6 Holes , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 0.6 Mm 8 Holed Without Gap , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 0.6 Mm 12 Holed Without Gap , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 0.6 Mm 16 Holed Without Gap , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 0.6 Mm 24 Holed Without Gap , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 0.8 Mm 10 Holes , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 0.8 Mm 12 Holes , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 0.8 Mm 16 Holes , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - L Plate Right Angle Short 1Mm 6 Holes Left , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - L Plate Right Angle Short 1Mm 6 Holes Right , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - L Plate Right Angle Long1mm6 Holes Right , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - L Plate Right Angle Long 1Mm6 Holes Left , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - L Plate Right Angle1mm Long5 Holes Right , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - L Plate Right Angle1mm Long5 Holes Left , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - Mini Plate4 Holes , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - Mini Plate 6 Holes , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - Mini Plate 8 Holes , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - Mini Plate 12 Holes , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - Mini Plate16 Holes , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - Mini Plate 20 Holes , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - Mini Plate With Bar 2 Holes , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - Mini Plate With Bar 4 Holes , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - Mini Plate With Bar 6 Holes , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - Y Plate 1 Mm 4 Holes Short , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - Y Plate 1 Mm 4 Holes Long , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - Double Y Platebroad 1 Mm6 Holes , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - T Plate 1 Mm 4 Holes , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - X Plate 1 Mm5 Holes , Titanium Reconstruction Plates (Plate Thickness 2Mm, Screw Diameter 2Mm) - Reconstruction Plate With Angleright 16 Holes , Titanium Reconstruction Plates(Plate Thickness 2Mm, Screw Diameter 2Mm) - Reconstruction Plate With Angleleft 16 Holes , Titanium Reconstruction Plates(Plate Thickness 2Mm, Screw Diameter 2Mm) - Reconstruction Plate With Angleright 20 Holes , Titanium Reconstruction Plates(Plate Thickness 2Mm, Screw Diameter 2Mm) - Reconstruction Plate With Angleleft 20 Holes , Titanium Reconstruction Plates(Plate Thickness 2Mm, Screw Diameter 2Mm) - Reconstruction Plate With Angleright 24 Holes , Titanium Reconstruction Plates(Plate Thickness 2Mm, Screw Diameter 2Mm) - Reconstruction Plate With Angleleft 24 Holes , Titanium Reconstruction Plates(Plate Thickness 2Mm, Screw Diameter 2Mm) - Reconstruction Plate - Straight - 16 Holes , Titanium Reconstruction Plates(Plate Thickness 2Mm, Screw Diameter 2Mm) - Reconstruction Plate Straight - 20 Holes , Titanium Reconstruction Plates(Plate Thickness 2Mm, Screw Diameter 2Mm) - Reconstruction Plate - Straight - 24 Holes , Titanium Screws For Kls Martin System1.5 X 4Mm (To Be Supplied With Screwdriver) , Titanium Screws For Kls Martin System1.5 X 6Mm(To Be Supplied With Screwdriver) , Titanium Screws For Kls Martin System1.5 X 8Mm (To Be Supplied With Screwdriver) , Titanium Screws For Kls Martin System1.5 X 10Mm (To Be Supplied With Screwdriver) , Titanium Screws For Kls Martin System1.5 X 12Mm (To Be Supplied With Screwdriver) , Titanium Screws For Kls Martin System 2Mm X 4Mm(To Be Supplied With Screwdriver) , Titanium Screws For Kls Martin System 2Mm X 6Mm(To Be Supplied With Screwdriver) , Titanium Self Drilling Screws 1.5 Mm , Length 4 Mm (Pack Of 1 Unit) , Titanium Self Drilling Screws 1.5 Mm , Length 5 Mm (Pack Of 1 Unit) , Self Drilling Screws 1.5 Mm Length 8 , Self Drilling Screws 2 Mm Length 4 , Self Drilling Screws 2 Mm Length 6 , Self Drilling Screws 2 Mm Length 8 , Titanium Midfacial (Outer Diameter 1.5Mm) Self-Tapping Screw-6 Mm Length (Pack Size - 1 No) , Titanium Mandible (Outer Diameter 2Mm) Self-Tapping Screw-6 Mm Length (Pack Size - 1 No) , Titanium Mandible (Outer Diameter 2Mm) Self-Tapping Screw-8 Mm Length (Pack Size - 1 No) , Titanium Reconstruction (Outer Diameter 2.3/2.4Mm) Self-Tapping Screw-10 Mm Length (Pack Size - 1 No) , Titanium Reconstruction (Outer Diameter 2.3/2.4Mm) Self-Tapping Maxi Screw-12 Mm Length (Pack Size - 1 No) , Breast Implant Insertion Device- Funnel Constructed Of A Flexible, Transparent, Polymeric Filmthat Accommodates A Variety Of Gel Breast Implant Shapes And Sizes , External Mandibular Distractors Unidirectional , External Mandibular Distractors Bidirectional , Intraoral Mini Distractors For Mandible Right 10Mm(Titanium) , Intraoral Mini Distractors For Mandible Right 15Mm (Titanium) , Intraoral Mini Distractors For Mandible Right 20Mm (Titanium) , Intraoral Mini Distractors For Mandible Right 25Mm (Titanium) , Intraoral Mini Distractors For Mandible Left 10Mm (Titanium) , Intraoral Mini Distractors For Mandible Left 15Mm (Titanium) , Intraoral Mini Distractors For Mandible Left 20Mm (Titanium) , Intraoral Mini Distractors For Mandible Left 25Mm (Titanium) , Intraoral Mini Distractors Vertical For Alveolar 2+2 Holes 3+3 Holes (Titanium) , Intraoral Mini Distractors For Maxilla Left (Titanium) , Intraoral Mini Distractors For Maxilla Right (Titanium) , Drill Bits 1.2/1.3 Mm Flute With Stop/Guard - Short , Drill Bits 1.2/1.3 Mm Flute With Stop/Guard - Long , Drill Bits 1.4/1.5 Mm Flute With Stop/Guard - Short , Drill Bits 1.4/1.5 Mm Flute With Stop/Guard - Long , Drill Bits 1.6 Mm Flute With Stop/Guard - Short , Drill Bits 1.6 Mm Flute With Stop/Guard - Long , Drill Bits 1.8 Mm Flute With Stop/Guard - Short , Drill Bits 1.8 Mm Flute With Stop/Guard - Long , Drill Bits 2.3 Mm Flute With Stop/Guard - Short , Drill Bits 2.3 Mm Flute With Stop/Guard - Long , Drill Bits 1.2/1.3 Mm Flute , Drill Bits 1.4/1.5 Mm Flute , Drill Bits 1.6 Mm Flute , Drill Bits 1.8 Mm Flute , Drill Bits 2.3 Mm Flute , Electric Dermatome Blades For Zimmer Dermatome , Acellular Dermal Matrix For Grafting/Implant Size: 2X2cm - Thick , Acellular Dermal Matrix For Grafting/Implant Size: 4X6cm - Thick , Acellular Dermal Matrix For Grafting/Implant Size: 8X16cm - Thick , Microscope Handle Drapes (180 X 330) , Sheathed Microtip Cautery Tips 4 Cm Straight (3/32”) Sleeve , Sheathed Microtip Cautery Tips 3 Cm Straight (3/32”) Sleeve , Bipolar Forceps Curved Type Bend 4 Tip 2 Mm For Bipolar Diathermy , Bipolar Forceps Straight 5 Tip 2Mm For Bipolar Diathermy , Bipolar Forceps Straighttip Bend 6Tip 2Mmfor Bipolar Diathermy , Bipolar Rf Cable For Bipolar Diathermy , Varispeed Battery Pack For Resorbable Implant System Strykar Delta System , Plates & Meshes For Resorbable Implant System Strykar - Straight Plate, 14 Holes, 1.4 Mm Thick , Plates & Meshes For Resorbable Implant System Strykar - Straight Plate, 21 Holes, 1.4 Mm Thick , Plates & Meshes For Resorbable Implant System Strykar - Straight Plate, 2 X 21 Holes, 1.4 Mm Thick , Plates & Meshes For Resorbable Implant System Strykar - Straight Plate, 2 X 21 Holes, 0.5 Mm Thick , Plates & Meshes For Resorbable Implant System Strykar - Straight Plate, 3 X 21 Holes, 0.5 Mm Thick , Plates & Meshes For Resorbable Implant System Strykar - Delta System, Ladder Plate, 2X 5 Holes , Plates & Meshes For Resorbable Implant System Strykar - Delta System Resorb Straight Plate 14 Holes , Plates & Meshes For Resorbable Implant System Strykar - Mesh 55 X 55 X 1.0 Mm , Plates & Meshes For Resorbable Implant System Strykar - Mesh 55 X 55 X 1.4 Mm , Plates & Meshes For Resorbable Implant System Strykar - Delta System Mesh- 55 X 55Mm , Screws Sizesfor Resorbable Implant System Strykar Delta Implant- Delta System, 1.7 X 4Mm Screw, Pkg. 10 , Screws Sizesfor Resorbable Implant System Strykar Delta Implant- Delta System, 1.7 X 5Mm Screw, Pkg. 10 , Screws Sizesfor Resorbable Implant System Strykar Delta Implant- 1.7 X 4 Mm, Pkg. 4 , Screws Sizesfor Resorbable Implant System Strykar Delta Implant- 1.7 X 5 Mm, Pkg. 4 , Screws Sizesfor Resorbable Implant System Strykar Delta Implant- 1.7 X 6 Mm, Pkg. 4 , Screws Sizesfor Resorbable Implant System Strykar Delta Implant- 2.2 X 4 Mm, Pkg. 2 , Screws Sizesfor Resorbable Implant System Strykar Delta Implant- 2.2 X 6 Mm, Pkg. 2 , Screws Sizesfor Resorbable Implant System Strykar Delta Implant- 2.6 X 4 Mm, Pkg. 2 , Screws Sizesfor Resorbable Implant System Strykar Delta Implant- 2.6 X 6 Mm, Pkg. 2 , Screws Sizesfor Resorbable Implant System Strykar Delta Implant- 2.6 X 8 Mm, Pkg. 2 , Screws Sizesfor Resorbable Implant System Strykar Delta Implant- 2.6 X 10 Mm, Pkg. 2 , Plate Holders & Cuttersfor Resorbable Implant System Strykar - 1.7 Mm Bone Tap , Plate Holders & Cuttersfor Resorbable Implant System Strykar - 2.2 Mm Bone Tap , Self-Holding Screws Drivers/Driver Bitsfor Resorbable Implant System Strykardelta System - 1.7 Mm Screwdriver Blade, 80 Mm , Taps (Ranging From 1.3 Mm To 4 Mm)For Resorbable Implant System Strykar Delta System - Self-Drilling Tap 1.7 Mm, 3 & 4 Mm, Dent , Taps (Ranging From 1.3 Mm To 4 Mm)For Resorbable Implant System Strykar Delta System - Self-Drilling Tap 1.7 Mm, 5 & 6 Mm, Dent , Taps (Ranging From 1.3 Mm To 4 Mm)For Resorbable Implant System Strykar Delta System - Self-Drilling Tap 2.2 Mm, 4 Mm, Dent , Taps (Ranging From 1.3 Mm To 4 Mm)For Resorbable Implant System Strykar Delta System - Self-Drilling Tap 2.2 Mm, 6 Mm, Dent , K- Wire 0.8 Mm Dia6 Length , K- Wire 1.2 Mm Dia6 Length , K- Wire 1.5 Mm Dia6 Length , K- Wire 1.6 Mm Dia6 Length , K- Wire 1.0 Mm Dia12 Length , K- Wire 1.2 Mm Dia12 Length , K- Wire 1.5 Mm Dia12 Length , Adsons Fine Toothed Forceps With 2Mm Fine Tip (Comfort Of Surgeon For Prolonged Handling Will Be Used As Selection Criteria) , Beaver Handles Round, Knurled, Stainless 10.0 Cm L X 0.50 Cm D , Beaver Handles Round, Knurled, Stainless 13.0 Cm L X 0.50 Cm D , Fine Toothed Forceps , Fine Tip Right Angled Forceps , Kilner Dott Mouth Gag With Three Blades (Set Of 2) - Pediatric Size , Mc Donalds Dissecting Forceps (For Lip) Fine - 1Mm , Skin Graft Blade For Humbys Knife , Ssg Handle (Humbys) , Skin Hook (Single) , Skin Hook - Fine (Single) , Scalpel Blade Remover , Thudiccum Nasal Speculum (All Sizes Each) , Zygoma Elevator , Langenbeck Retractor , Non-Stick Bipolar Cable , Non-Stick Bipolar Forceps Fine Tips - Small , Non-Stick Bipolar Forceps Fine Tips - Medium , Non-Stick Bipolar Forceps Fine Tips - Large , Non-Stick Bipolar Forceps Fine Tips - Angled , Proctoscope - Small , Proctoscope - Medium , Proctoscope - Large , Bayonet Forceps , Dissecting Forceps (Toothed)-12 Cm , Dissecting Forceps (Non-Toothed)-12 Cm , Mosquito Forceps - Straight - 12 Cm , Mosquito Forceps - Curved - 12 Cm , Iris Scissors - Straight -12 Cm , Iris Scissors - Curved -12 Cm , Acrylic -Heat Cure-Clear (Pack 450Gm Powder & 275Ml Liquid) , Acrylic -Heat Cure-Pink (Pack 450Gm Powder & 275Ml Liquid) , Acrylic -Self Cure-Clear (Pack 400Gm Powder & 400Ml Liquid) , Acrylic -Self Cure-Pink (Pack 400Gm Powder & 400Ml Liquid) , Alginate Impression Material (Dustless) Pack Of 750Gm , Carborundum Discs (For Mandrel Mount) - Pack Of 10 , Cold Mount Seal (Pack Of 450Ml) , Dappen Dish (Pack Size - 1 No.) , Dental Stone (Pack Of 3 Kg) , Die Stone (Pack Of 3 Kg) , Disc Mandrel (Pack Size - 1 No.) , Modelling Wax Sheet No.2 (Pack Of 10 Sheets) , Mouth Mirror With Handle (Pack Size - 1 No.) , Plaster Of Paris (Type Ii) (Pack Of 5 Kgs) , Polishing Buff For Dental Lathe (Pack Size - 1 No.) , Pumice Powder For Polishing Dentures (Pack Of 2 Kg) , Sandpaper Mandrel (Pack Size - 1 No.) , Soft Putty Impression Material (Pack Of 450Ml Soft Putty And 180Ml Light Body) , Stainless Steel Wire- 26 Guage (Pack Size - 1 No.) , Stainless Steel Wire- 32 Guage (Pack Size - 1 No.) , Vulcanite Trimmer (Tc) (Pack Size - 1 No.) , Micromotor Straight Handpiece For Use With Surgical Burs And Cutters Should Carry Standard/Ce Certified.Warranty - 2 Years (Pack Size - 1 No.) , Adams Plier (Pack Size - 1 No.) , Cheek Retractor - Clear (Pair Of 2) , Plier Stand - Stainless Steel (Pack Size - 1 No.) , Tweed Loop Forming Plier (Pack Size - 1 No.) , Elastics - Red (Pack Of 1000) , Elastics - 3/16-4.5 Oz. (Pack Of 1000) , Orthodontic Plastic Model Bases (Pack Size - 1 No.) , Orthodontic Stone (3Kg Pack) , Stainless Steel Wire - 0.7Mm (Spool Of 500Gms) , Anodised Aluminium Tray With Mat And Continuous Holders - Dimensions:9X7x1.25 , Micro Jewellers Forcepsstraight - Matte Finish 6 Length(Comfort Of Surgeon For Prolonged Holding, Ability Of Tip To Hold Both Microneedle And Microsuture Will Be Used As Selection Criteria) , Micro Jewellers Forceps Angled - Matte Finish 6 Length, Less Than 5Mm Angled Arm With Less Than 1Mm Tip(Comfort Of Surgeon For Prolonged Holding, Ability Of Tip To Hold Both Microneedle And Microsuture Will Be Used As Selection Criteria) , Micro Jewellers Forcepscurved - Matte Finish 0.2Mm Tip(Comfort Of Surgeon For Prolonged Holding, Ability Of Tip To Hold Both Microneedle And Microsuture Will Be Used As Selection Criteria) , Micro Needle Holder - Curved - 6 Length 0.6 Mm Wide Jaw- Castroveijo Type Without Lock (Comfort Of Surgeon For Prolonged Holding, Ability Of Tip To Hold Both Microneedle And Microsuture Will Be Used As Selection Criteria) , Micro Needle Holder Castroveijo Type Without Lock Straight - 15 Cm , Vessel Clamps (Single Pair) - 2A , Vessel Clamps (Single Pair) - 2V , Vessel Clamps (Single Pair) - 3A , Vessel Clamps (Single Pair) - 3V , Vessel Clamps (Single Pair) - 4A , Vessel Clamps (Single Pair) - 4V , Tenotomy Scissors - 5/6 Curved , Tenotomy Scissors Long - 10-12 Curved , Tenotomy Scissors Long - 8 Curved , Titanium Vessel Dilator, Angled, 0.2Mm Tip , Titanium Vessel Dilator, Straight, 0.2Mm Tip , Titanium Vessel Dilator, Short Model , Micro Ring Forceps, 6 , Micro Vessel Dilator, Long Model, Straight, Matt Finish , Micro Vessel Dilator Forceps, Parallel Flattened With Round Handle, Straight, 5/6 Inch Length 0.6-1Mm Wide Tip (0.2Mm Tip) , Micro Scissors 5/6 , Straight, Blunt Tip, Round Handle Castroviejo Type , Micro Scissors 5/6 , Curved, Blunt Tip, Round Handle Castroviejo Type , Micro Scissors 5/6 , Straight, Sharp Tip, Round Handle Castroviejo Type , Micro Scissors 5/6 , Curved, Sharp Tip, Round Handle Castroviejo Type , Mixter Right Angled Forceps (Set Of 3) , Titanium Micro Forceps With Platform, 15 Cm Long , Sterilizer Box With 1 Silicon Mat , Ss Beaker With Silicon Mat , Orthopedic T-Handle , Insulated Bipolar Forceps, Adson, Fine Tip 5 (Autoclavable And Reusable, Non-Stick) , Insulated Bipolar Forceps, Adson, Fine Tip 6 (Autoclavable And Reusable, Non-Stick) , Insulated Bipolar Forceps, Bayonet, Fine Tip 6 (Autoclavable And Reusable, Non-Stick) , Insulated Bipolar Forceps, Adson, Fine Tip 5 (Autoclavable And Reusable) , Insulated Bipolar Forceps, Fine Tip 6 (Autoclavable And Reusable) , Insulated Bipolar Forceps, Bayonet, Fine Tip 6 (Autoclavable And Reusable) , Debakey Medium Vascular Size Forceps 6 , Bulldog Clamps, Atraugrip Jaws, Straight - 1Mm/2Mm Tip , Bulldog Clamps, Atraugrip Jaws, Angled - 1 Mm/2 Mm Tip , Bulldog Clamps, Atraugrip Jaws, Curved - 1 Mm/2 Mm Tip , Vessel Anastomotic Coupler- 1 Mm , Vessel Anastomotic Coupler- 1.5 Mm , Vessel Anastomotic Coupler- 2 Mm , Vessel Anastomotic Coupler- 2.5 Mm , Vessel Anastomotic Coupler- 3 Mm , Vessel Anastomotic Coupler- 3.5 Mm , Vessel Anastomotic Coupler- 4 Mm , Bulldog Disposable Vascular Clamps-Small , Bulldog Disposable Vascular Clamps-Medium , Liga Clips Micro Clips , Liga Clips Medium , Liga Clips Small , Coupler Forceps , Vessel Measuring Gauge , Fine Suction Nozzle - Size : 2 And 3 , Alar Retractor , Vessel Dilator - 0.2 Mm Tip Straight , Vessel Clamp Applicator , Micro Clamps Applicators (Forceps), 6 Long, Matt Finish (Should Be Compatible With The Vessel Clamps Provided) , Pediatric Mosquito Artery , Needle Holder Medium & Fine Tip (1Mm/2Mm) , Needle Holder Fine -12 Cm , B.P. Handle No. 3 , Head Base Ring Gel Pad - Adult Size , Head Base Ring Gel Pad - Pediatric Size , Head Base Gel Pad- Adult Size , Head Base Gel Pad- Pediatric Size , Head Neck Base Gel Pad- Adult Size , Sacral Pad- Adult Size , Heel Pad- Adult Size , Horseshoe Gel Pad Without Base - Adult Size , Knee/Arm Rest Gel Pad - Adult Size , Knee/Arm Rest Gel Pad - Pediatric Size , Gel Prone Head Rest , Chest Roll Gel Pad (Dome Positioner Prime)- Adult Size , Chest Roll Gel Pad (Dome Positioner Prime)- Pediatric Size , Universal Gel Pillows - Adult Size , Universal Gel Pillows - Pediatric Size , Neonatal Roll - Should Contain Different Sizes , Pediatric Roll- Should Contain Different Sizes , Human Acellular Matrix Preserved In Propriety Glycerol Based Solution With More Than 97% Of Donor Dna Removed & Sterility Assurance Level Of 10-6. Facilitating Recipient Cellular Infiltration And Revascularization. Biohospitable & Ready To Use Without Rehydration.Thickness 0.2-1Mm. Meshed Size (Cm) 2X2cm , Human Acellular Matrix Preserved In Propriety Glycerol Based Solution With More Than 97% Of Donor Dna Removed & Sterility Assurance Level Of 10-6. Facilitating Recipient Cellular Infiltration And Revascularization. Biohospitable & Ready To Use Without Rehydration.Thickness 0.2-1Mm. Meshed Size (Cm) 3X3cm , Human Acellular Matrixpreserved In Propriety Glycerol Based Solution With More Than 97% Of Donor Dna Removed & Sterility Assurance Level Of 10-6. Facilitating Recipient Cellular Infiltration And Revascularization. Biohospitable & Ready To Use Without Rehydration. Thickness 0.2-1Mm. Meshed Size (Cm) 4X4cm , Human Acellular Matrixpreserved In Propriety Glycerol Based Solution With More Than 97% Of Donor Dna Removed & Sterility Assurance Level Of 10-6. Facilitating Recipient Cellular Infiltration And Revascularization. Biohospitable & Ready To Use Without Rehydration. Thickness 0.2-1Mm. Meshed Size (Cm) 5X7cm , Human Acellular Matrixpreserved In Propriety Glycerol Based Solution With More Than 97% Of Donor Dna Removed & Sterility Assurance Level Of 10-6. Facilitating Recipient Cellular Infiltration And Revascularization. Biohospitable & Ready To Use Without Rehydration. Thickness 0.2-1Mm. Meshed Size (Cm) 6X7cm , Human Acellular Matrixpreserved In Propriety Glycerol Based Solution With More Than 97% Of Donor Dna Removed & Sterility Assurance Level Of 10-6. Facilitating Recipient Cellular Infiltration And Revascularization. Biohospitable & Ready To Use Without Rehydration. Thickness 0.2-1Mm. Meshed Size (Cm) 4X8cm , Human Acellular Matrixpreserved In Propriety Glycerol Based Solution With More Than 97% Of Donor Dna Removed & Sterility Assurance Level Of 10-6. Facilitating Recipient Cellular Infiltration And Revascularization. Biohospitable & Ready To Use Without Rehydration. Thickness 0.2-1Mm. Meshed Size (Cm) 5X9cm , Human Acellular Matrixpreserved In Propriety Glycerol Based Solution With More Than 97% Of Donor Dna Removed & Sterility Assurance Level Of 10-6. Facilitating Recipient Cellular Infiltration And Revascularization. Biohospitable & Ready To Use Without Rehydration. Thickness 0.2-1Mm. Unmeshed Size (Cm) 2X2cm , Human Acellular Matrixpreserved In Propriety Glycerol Based Solution With More Than 97% Of Donor Dna Removed & Sterility Assurance Level Of 10-6. Facilitating Recipient Cellular Infiltration And Revascularization. Biohospitable & Ready To Use Without Rehydration.Thickness 0.2-1Mm. Unmeshed Size (Cm) 4X4cm , Human Acellular Matrixpreserved In Propriety Glycerol Based Solution With More Than 97% Of Donor Dna Removed & Sterility Assurance Level Of 10-6. Facilitating Recipient Cellular Infiltration And Revascularization. Biohospitable & Ready To Use Without Rehydration. Thickness 0.2-1Mm. Unmeshed Size (Cm) 5X7cm , Human Acellular Matrixpreserved In Propriety Glycerol Based Solution With More Than 97% Of Donor Dna Removed & Sterility Assurance Level Of 10-6. Facilitating Recipient Cellular Infiltration And Revascularization. Biohospitable & Ready To Use Without Rehydration.Thickness 0.2-1Mm. Unmeshed Size (Cm) 6X7cm , Human Acellular Matrixpreserved In Propriety Glycerol Based Solution With More Than 97% Of Donor Dna Removed & Sterility Assurance Level Of 10-6. Facilitating Recipient Cellular Infiltration And Revascularization. Biohospitable & Ready To Use Without Rehydration.Thickness 0.2-1Mm. Unmeshed Size (Cm) 4X8cm , Disposable Negative Pressure Wound Therapy Kit With Multilumen Tubing And Peri Wound Protection Layer- Size: Small 1) Should Contain Hydrophobic Pu Foam Size: 11Cm X 8Cm X 3Cmadhesive Drapes 2) Should Contain Multilumen Tubing, Connector, Clamp And Tube Holder 3) Should Contain Repositionable Peri-Wound Protection Layer , Disposable Negative Pressure Wound Therapy Kit With Multilumen Tubing And Peri Wound Protection Layer- Size: Medium 1) Should Contain Hydrophobic Pu Foam Size: 17Cm X 15Cm X 3Cm Adhesive Drapes 2) Should Contain Multilumen Tubing, Connector, Clamp And Tube Holder 3) Should Contain Repositionable Peri-Wound Protection Layer , Disposable Negative Pressure Wound Therapy Kit With Multilumen Tubing And Peri Wound Protection Layer- Size: Large 1) Should Contain Hydrophobic Pu Foam Size: 26Cm X 15Cm X 3Cm Adhesive Drapes 2) Should Contain Multilumen Tubing, Connector, Clamp And Tube Holder 3) Should Contain Repositionable Peri-Wound Protection Layer , Negative Pressure Wound Therapy Dressing With Instillation 1) Containing Multilayer Hydrophobic And Hydrocellular Foam Dressings-Size: Small (7.5Cm X 10Cm X 1.6Cm)X1 And (7.5Cm X 10Cm X 1Cm)X1 And Adhesive Drapes 2) Should Contain Multi-Lumen Tubing, Connector, Clamp And Tube Holder 3) Should Contain Repositionable Peri-Wound Protection Layer , Negative Pressure Wound Therapy Dressing With Instillation 1) Containing Multilayer Hydrophobic And Hydrocellular Foam Dressings-Size:Medium (12.5 X 18 X 1.6Cm)X1 And (12.5 X 18 X 1Cm)X1 And Adhesive Drapes 2) Should Contain Multi-Lumen Tubing, Connector, Clamp And Tube Holder 3) Should Contain Repositionable Peri-Wound Protection Layer , Negative Pressure Wound Therapy Dressing With Instillation 1) Containing Multilayer Hydrophobic And Hydrocellular Foam Dressings-Size: Large ( 26Cm X 15Cm X 1.6Cm)X1 And (26Cm X 15Cm X 1Cm)X1 And Adhesive Drapes 2) Should Contain Multi-Lumen Tubing, Connector, Clamp And Tube Holder 3) Should Contain Repositionable Peri-Wound Protection Layer , Negative Pressure Wound Therapy Cansiter 500Ml And Instillation Head Connector For Instillation Therapy System- 1) Should Contain 500Ml Container With Multilumen Tubing & Clamp 2) Should Contain Instillation Flow Tracker /Irrigation Head/ Casette , Dynamic Incision Management Kit (Size: 4.5Cm X 20Cm) Compatible With Palm Size Dynamic Incision Management System 1)Should Contain Hydrophobic Pu Foam Peel And Place Dressing 2)Low Adherent Soft Silicon Contact Layer With Additional (Adhesive) Fixation Strips 3)Should Be Compatible With Palm Sized Negative Pressure Incision Wound Management Device (Light Weight Device Upto 200G) With Atleast 4 Pressure Settings (-50Mmhg To -125Mmhg) 4)Should Be Compatible With 100Ml-150Ml Canister , Dynamic Incision Management Kit (Size: 4.5Cm X 25Cm) Compatible With Palm Size Dynamic Incision Management System 1)Should Contain Hydrophobic Pu Foam Peel And Place Dressing 2)Low Adherent Soft Silicon Contact Layer With Additional (Adhesive) Fixation Strips 3)Should Be Compatible With Palm Sized Negative Pressure Incision Wound Management Device (Light Weight Device Upto 200G) With Atleast 4 Pressure Settings (-50Mmhg To -125Mmhg) 4)Should Be Compatible With 100Ml-150Ml Canister , Dynamic Incision Management Kit (Size: 4.5Cm X 30Cm) Compatible With Palm Size Dynamic Incision Management System 1)Should Contain Hydrophobic Pu Foam Peel And Place Dressing 2)Low Adherent Soft Silicon Contact Layer With Additional (Adhesive) Fixation Strips 3)Should Be Compatible With Palm Sized Negative Pressure Incision Wound Management Device (Light Weight Device Upto 200G) With Atleast 4 Pressure Settings (-50Mmhg To -125Mmhg) 4)Should Be Compatible With 100Ml-150Ml Canister , Dynamic Incision Management Kit (Size: 4.5Cm X 35Cm) Compatible With Palm Size Dynamic Incision Management System 1)Should Contain Hydrophobic Pu Foam Peel And Place Dressing 2)Low Adherent Soft Silicon Contact Layer With Additional (Adhesive) Fixation Strips 3)Should Be Compatible With Palm Sized Negative Pressure Incision Wound Management Device (Light Weight Device Upto 200G) With Atleast 4 Pressure Settings (-50Mmhg To -125Mmhg) 4)Should Be Compatible With 100Ml-150Ml Canister , Dynamic Ulcer Management Kit (Size: 14Cm X 12Cm) Compatible With Palm Size Dynamic Incision Management System 1)Should Contain Hydrophobic Pu Foam Peel And Place Dressing 2)Low Adherent Soft Silicon Contact Layer With Additional (Adhesive) Fixation Strips 3) Should Be Compatible With Palm Sized Negative Pressure Incision Wound Management Device (Light Weight Device Upto 200G) With Atleast 4 Pressure Settings (-50Mmhg To -125Mmhg) 4) Should Be Compatible With 100Ml-150Ml Canister , Dynamic Ulcer Management Kit (Size: 15Cm X 17.5Cm) Compatible With Palm Size Dynamic Incision Management System 1)Should Contain Hydrophobic Pu Foam Peel And Place Dressing 2)Low Adherent Soft Silicon Contact Layer With Additional (Adhesive) Fixation Strips 3) Should Be Compatible With Palm Sized Negative Pressure Incision Wound Management Device (Light Weight Device Upto 200G) With Atleast 4 Pressure Settings (-50Mmhg To -125Mmhg) 4) Should Be Compatible With 100Ml-150Ml Canister , Container With Gel For Palm Size Dynamic Incision Management System (150Ml) 1) Transparent Container With Gel To Collect Exudate 2) Should Be Compatible With Palm Sized Negative Pressure Incision Wound Management Device (Light Weight Device Upto 200G) With Atleast 4 Pressure Settings (-50Mmhg To -125Mmhg) 3) Should Be Compatible With Dynamic Incision Management Kits , Mini Sagittal Saw Compatible With Stryker Handpiece For Craniotomy , Three Pin Head Rest For Craniotomy , Mayfield Horseshoe Headrest - Adult For Craniotomy , Mandible Bone Holding Reduction Clamp Serrated With Ratchet (Basic Bone Plating Instrument Set) , Straight Cutting Pliers - 6 Length, 2/3 Mm Wide Tip(Basic Bone Plating Instrument Set) , Bone Elevator Hoffmann Type 6 Mm (Basic Bone Plating Instrument Set) , Bone Elevator Hoffmann Type 8 Mm(Basic Bone Plating Instrument Set) , Fine Osteotome - Curved 2 Mm (For Rhinoplasty) , Fine Osteotome - Curved 4 Mm (For Rhinoplasty) , Fine Osteotome - Straight 2 Mm (For Rhinoplasty) , Fine Osteotome - Straight 4 Mm(For Rhinoplasty) , Neiverts Guarded Osteotome - Right (For Rhinoplasty) , Neiverts Guarded Osteotome - Left (For Rhinoplasty) , Guarded Osteotome Straight (For Rhinoplasty) , Guarded Osteotome Curved (For Rhinoplasty) , Joseph Bone Rasp - Cross-Serrated (For Rhinoplasty) , Joseph Bone Rasp - Double Action (For Rhinoplasty) , Cottles Glabella Rasp (For Rhinoplasty) , Mcindoes Double-Ended Periosteal Elevator (For Rhinoplasty) , Aufritch Nasal Dorsal Retractor (For Rhinoplasty) , Aschs Septal Forceps (For Rhinoplasty) , Walshams Nasal Forceps - Adult (For Rhinoplasty) , Walshams Nasal Forceps- Paediatric (For Rhinoplasty) , Tessier Osteotomes Straight 2 Mm(For Osteotomy) , Tessier Osteotomes Straight 5 Mm (For Osteotomy) , Tessier Osteotomes Straight 10Mm (For Osteotomy) , Tessier Osteotomes Straight 15 Mm (For Osteotomy) , Tessier Osteotomes Curved 2 Mm(For Osteotomy) , Tessier Osteotomes Curved 5 Mm(For Osteotomy) , Tessier Osteotomes Curved 10 Mm (For Osteotomy) , Fine Chisels Straight 2 Mm (For Osteotomy) , Fine Chisels Straight 4 Mm (For Osteotomy) , Fine Chisels Straight 6 Mm (For Osteotomy) , Fine Chisels Curved 2 Mm (For Osteotomy) , Fine Chisels Curved 4 Mm (For Osteotomy) , Fine Chisels Curved 6 Mm (For Osteotomy) , Pterygoid Osteotome 5 Mm (For Osteotomy) , Pterygoid Osteotome 10 Mm (For Osteotomy) , Pterygoid Osteotome Curved (Lefort) 1Mm, 2Mm , Bone Cutting Forceps Double Action Curved (For Osteotomy) , Arm Boardcompatible With Dr Lite Model 7000 Sb , Arm Rest For Lateral Position Compatible With Dr Lite Model 7000 Sb , Silicon Head Ring - Adult , Silicon Head Ring - Pediatrics , Fine Tendon Hook , Cats Paw Skin Retractor. , Roberts Artery Forceps , Babcock 6 Tissue Holding Forceps , Pds Plate , Russian Artery Forceps , Microinstrument Set Sterlising Case ( 20 Cm X 12 Cm) , Vessel Loop (Fine) , Micro Clip Applicator
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 34
8.
Defence #11167640 AOC
Tender For Provision Of Single Men Barracks Including Cook House For Agniveers At Brc, Danapur.; 1 SCHEDULE A Part-I (Building/Structures) (To be quoted by the tenderer) 2 Item No 01 A : Design and construction of 180 ORs SM BarrackComplete allspecified in soil bearing capacity report, design basis report, drawings and tender documents. 3 Item No 01 B: Design and construction of Dinning Hall Complete allspecified in soil bearing capacity report, design basis report, drawings and tender documents. 4 Item No 01C : Design and construction of Cook House Complete allspecified in soil bearing capacity report, design basis report, drawings and tender documents. 5 Sch A Part-II (Internal Electrification)Lump sum price worked out by the contractor for (Internal Electrification) as listed in Schedule A Part-II against the lump sum price inserted by the MES. 6 Sch A Part-III (External Electric Supply)Lump sum price worked out by the contractor for (External Electric Supply) as listed in Schedule A Part-III against the lump sum price inserted by the MES. 7 Sch A Part-IV(External Water supply)Lump sum price worked out by the contractor for (External Water supply) as listed in Schedule A Part-IV against the lump sum price inserted by the MES. 8 Sch A Part-V(Road, Path Curvert)Lump sum price worked out by the contractor for (Road, Path Curvert)as listed in Schedule A Part-V against the lump sum price inserted by the MES. 9 Sch A Part-VI (Air Conditioning)Lump sum price worked out by the contractor for (Air Conditioning) as listed in Schedule A Part-VI against the lump sum price inserted by the MES. 10 Sch A Part-VII(Refrigeration System)Lump sum price worked out by the contractor for (Refrigeration System) as listed in Schedule A Part-VII against the lump sum price inserted by the MES. 11 Sch A Part-VIII((FIRE FIGHTING SYSTEM(DOWN COMMER) & FIRE ALARM SYSTEM)Lump sum price worked out by the contractor for ((FIRE FIGHTING SYSTEM(DOWN COMMER) & FIRE ALARM SYSTEM) as listed in Schedule A Part-VIII against the lump sum price inserted by the MES. 12 Sch A Part-IX(Demolition of Bld (B/R) Lump sum price worked out by the contractor for (Demolition of Bld (B/R)as listed in Schedule A Part-IX against the lump sum priceinserted by the MES. 13 Sch A Part-X(Sewage Disposal) Lump sum price worked out by the contractor for (Sewage Disposal)as listed in Schedule A Part-X against the lump sum priceinserted by the MES. 14 Sch A Part-XI(Area Drainage)Lump sum price worked out by the contractor for (Area Drainage) as listed in Schedule A Part-XI against the lump sum price inserted by the MES. 15 Sch A Part-XII(Site Clearance) Lump sum price worked out by the contractor for (Site Clearance)as listed in Schedule A Part-XII against the lump sum priceinserted by the MES. 16 Note for Srl No 2 to 15The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 2 to 14by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule 17 Schedule A Part-XIII (Miscellaneous items of works) 18 INTERNALELECTRIFICATION 19 Item No 02 : Materialand labour for point wiring complete with 1.5 sqmm PVC insulated, FRLSH type, ISI marked,conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20 mm dia medium grade(MMS/HMS) andincluding cutting, chasing work at any height and all accessoriesconcealedinwalls / roofs / floors / ceiling etc. 20 flush mountingMS box with top,bottom,side/back wall knockout for conduitentry from any direction made out of 1.60mm thick suitable for fixing of andincludingwhite/Silver/Dark bronzecolour modular blankingplate as per number of switch modules flush mountedfor fixing of modular switches,sockets,fan regulators, blank plate etc and including above mentioned colourmodular plate cover of required modules andincluding 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade with putty for smooth finishing complete all as specified and directedfor the following:- 21 (a) One light point controlled by one switch. 22 (b) Onefan point controlled by one switch and oneregulator. 23 (c) Oneexhaust fan point controlled by one switch . 24 (d) One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board . 25 (e) One 5 pin 6 amps socket point controlled by one 6 amps switch on same board . 26 (f) One bell/buzzer point controlled by one bell push. 27 (g) One light point controlled by two 2 way switches. 28 Item No 02 : All as per item No.1(d) & (e) above,but point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all as specified and directed for the following:- 29 (a) One 6 pin 16/6 amps socket outlet point controlled by one 16 amps switchon independent board. 30 (b) One 6 pin 16/6 amps socket outlet point controlled by one 16 amps switch on same board. 31 Item No 03 :All as per item No.1 (d) above ,but point wiring with 4.0 sqmm and earth conductor of size 4 sqmm complete all as specified and directed. 32 Item No 04 : Supply & fixingand sheet metal enclosurewith acrylic door type, double door ,415 volts AC,VTPNDB, 4 way,8+12 modules, flush mounting with 200amps copper busbar, 2 neutral/earth bars links and MCCB incomer,and MCB SPN/SP/TPNas outgoing and complete forIP43&54 DBs protection complete all as specified and as directed. Note for item No.22 to 32- MCCB/MCB DBs and MCBs/MCCBs both are used same make only 33 Item No 05: Material and labour for Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres belowground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipeof 15 mm diafrom earth electrode up to test point or up to 7.5mtr whichever is less by means of GIbolts, nuts, check nuts and washersall as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM,RCC cover 1:2:4 type B1 of size 45X45X6CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required valueincluding removing old item completeall as specified and directed. 34 External Electric supply 35 Item No 06 :Supply, installation, testing and commissioning of step down copper wound transformer of capacity 315 KVA (Energy Efficient LEVEL 3 ), outdoor type, plinth platform of min size 2.4 x 2.4 x 1.5 Mtr (Solid PCC Block) complete with standard fittingts and accesswories, HT 11 KV 3 phase, Lt 433 volts, 3 phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:1180 (Part-I)-2014 (latest edition) with amendment no. 1,2,3 & 4 (Level 3). oil cooling with fins vector group: DYN 11, incl initial oil fitting complete all as specified incl the following accessories:- 36 a) three numbers porcelain bushing HT, 11KV with Brass bushing Rod, Nuts, bolts and washers etc inside cable end box b) One cable box LT side consisting of 4 numbers porcelain with brass bushing rods complete with nuts and washers suitable for runs of 3.5 core LT UG cables c) Oil conservator with filter type drain valve and oil level guage 37 d) Dehydrating breather with fast feel of dehydrating agent e) Explosion Vents f) thermometer pocket on tank cover g) Rating Plate on terminal marking plate h) Earthing arrangement i) Oiil drain filter valve j) Oil Drain Valvek) Lifting Hook 38 l) Oil conservator with filling hole and capm) Air release valve plugn) Four plate solid cast steel detachable rollerso) Buchholz relay p) Earth Bushing for neutral Outside the cable box for neutralq) Suitable size of channel on foundation for fixing the transformer with jint and stopper(r) Plateform for mounting of transformer made up of PCC 1:2:4, 20 mm graded stoen aggregate, solid block and making all faces fare using extra cement as per manufacturer design of required length, width and hight in and including providing of 02 nos ISMC 100 chanel embe3dded in PCC of wuitable length as directed at site by the engr in charge in and including earth work complete. 39 Note: (i) Anything missed out above but technically required for proper operation of transformer is deemed to be included in the quoted rate. 40 Item No 07 : Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm complete all as specified and as directed. 41 Item No 08 : Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sqmm 3½ core complete all as specified and as directed. 42 Item No 09 : Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sqmm 3½ core complete all as specified and as directed. 43 Item No 10 : Supply and fix cable jointing kit for 1.1 KV grade cable for straight through/ end terminal joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 95 sqmm,Indoor/Outdoor type complete all as specified and as directed. 44 Item No 11 : Supply ,fabrication, installation and testing of LT out door type factory made CPRI Approved ,feeder piller box of made out of 3.15 mm thick CRCA sheet dully supported with mild steel angle iron of size 40X40X5mm vertical legs frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incomming existing cable of any size drawing / digging out cable from loops in trenches inclusive of necessary excavation and earthwork as required and relaying the cables including the following fitment accessories all complete as specified and as directed. 45 Incoming (a)MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 35 KA breaking capacity, rating 400 Amps including all fixing accessories with both ends spreader links-01 No. (b)Digital voltmeter of range (0-500) volts, flush mounting type of size 96mm x 96mm (4”x4”) square dial with selector switch – 01 No.(c)Digital Ammeter of range (0-250) Amps, flush mounting type of size 96mm x 96mm (4”x4”) square dial with selector switch – 01 No.(d)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts,AC -01 set (set of three). 46 Outgoing(a)MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 36 KA breaking capacity, rating 250 Amps including all fixing accessories with both ends spreader links-01 No. 47 (b)MCB,4 pole, 415V, C series rating 200Amp Amps including all fixing accessories with both ends spreader links-02 No. (01 + 01 spare) 48 (c ) Copper strip busbar of 600 Amps current carrying capacity with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 nos. 49 (d)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No. 50 Item No 12 :M&L for Shifting of existing VCB from existing location near pump house No:2 over head tank to proposed building approx 300 Mtr with the help of crane including necessary T&P including Servicing, comprising of overhauling and refixing the same after repairs: (a) Tripping off the breaker, lowering the breaker with raising/lowering handle and pulling out the breaker complete from the panel along with the trolley for servicing/inspection.(b) Servicing/Inspecting/checking of automatic safety shutter operation for serviceability and replacement of spares if required. 51 (c) Servicing/Inspecting/checking ofcircuit spoutand cicuit spout connections for RYB phases and replacement of spares if required.(d) Dismantling and checking of cross bar assembly, fixed contacts and current carrying parts of the breaker, trolley, insulated assembly and checking lamination with clamps, epoxy spout, isolator assembly etc. (e) Setting, reassembling, cleaning, adjustment of fixed contacts, main contact, arcing contacts and chamber baffle pot assembly, moving contact for proper setting of auxiliary contacts operating mechanism. (f)Servicing/Inspecting/checking ofsecondary sockets/busbar earthing plugs/earthing sockets and replacement of spares if required. 52 (g)Checking, setting and adjustment of lowering and raising operation of the breaker trolley. (h)Lubrication and greasing of all moving parts of the trolley, stopper bolt for proper operating and closing of shutter gear, isolation resistance of trolley of with vacuum interrupter assembly. (j) The inspection of HT switch gear shall involve:-(i) Inspection of truck & hoist assembly.(ii) Inspection of tank assembly & barriers.(iii) Inspection of assembly & components of solenoid assembly.(iv) Inspection of assembly & components of dependent mechanism.(v)Inspection of assembly & components of spring box mechanism.(vi)Inspection of motor mechanism spring charge assembly (vii)Inspection of assembly of trip unit & related components.Notes: (i) The rate quoted shall be deemed to include for necessary T&P, nuts, bolts, washers, gasket, insulation tape, compound and any damaged parts etc. to put in to the VCBs and panels in serviceable condition, testing and commissioning all as specified and as directed by the Engineer-in-Charge. 53 Item No 13 : M&L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure. 54 Item No 14 : M&L Costruction of a 18 sqm room with a height of 3.5 mtrs, designed to house a vaccum circuit breaker (VCB). The costruction will include foundation work, walls, roofing , flooring, plastering and miscellaneous items like windows and doors. complete all as specified and as directed. 55 External Water Supply 56 Item No 15 : M & L for Construction of brick masonry valves pits , of the following internal dimension complete with 3015mm thick MS sheet cover angle iron frame duly painted with locking arrangement including all necessary excavation and earth work PCC wok complete. 57 (a) 900mm x 900mm x 900mm 58 (b) 600mm x 600mm x 600mm 59 Item No 16 : Refixing MS/ GI/ CI DI pipe any type and connections in new or old position including cleaning internally and externally, any grade / make (in trenches) including all type of new fittings i.e. sockets, Tee, union, elbow etc complete all as specified and as directed. 60 (a)100 mm dia 61 (b) 150 mm dia 62 Item No 17 : Supply and fixing in replacement ductile iron pressure pipes, class K7, centrifugally cast with spigot and socket ends as per following conforming to IS 8329/2000 with cement mortar lining inside the pipes with outside zinc coating suitable for push-on joint (rubber gasket D jointing) in any length including DI specials as required at site confirming to IS 8329/2000 and all jointing materials and making good for distrubed surfaces of roads, pathways etc while laying the pipe line at site, site clearance for the route of pipe line, welding, excavation of pipe line, connections etc complete all as specified and as directed. (a) 150 mm dia 63 Refrigeration System 64 Item No 18 : Supply and fix refrigerator, electric driven (single phase), capacity upto to 195 Litres .BEE 5 star rated complete all as specified and directed. 65 Item No 19 :Supply and installation of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA. 66 Water cooler 67 Item No 20 : Supply, installation and Commissioning water cooler, Electric driven,(single phase 230 volts) having approx storage capacity of 120 Litres and nominal cooling capacity of 60 Litres per hour complete all as specified. 68 Item No 21 : Supply and installation of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of ± 2.5% and of capacity 2 KVA complete all as specified. 69 Air Conditioning 70 Item No 22 : Supply and installation of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified. 71 Hot Water Supply 72 Item No 23 : Supply and fix Water heater storage type, electric,capacity 50 litres.BEE 5 star rated 73 Item No 24 : Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece complete all as specified and directed. 74 Dessert Cooler 75 Item No 25 : Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 4000 CuM per hour (or nearest size).Steel body type complete all as specified and directed. 76 Electric Chimney 77 Item No 26 : Supply, installation testing and commissioning commercial kitchen chimney stainless steel body with filter size 96 X 30 including 1 HP exhust fan, Air outlet duck of chimney G.P sheet 0.50 mm thick of size 22 X 22 X 15 ft long complete all as specified and directed. 78 FIRE FIGHTING SYSTEM(DOWN COMMER) & FIRE ALARM SYSTEM 79 Item No 27 : Supply only of fire extinguiser ISI marked CO2 type Fire Extinguisher 4.5 KG capacity conforming to IS : 15683 :2006 (old IS : 2878) made from seamless cylinder conforming to IS : 7285 duly approved by chief controller of explosive , Nagpur fitted with ISI Marked Controlled valve conforming to IS : 3224 , high pressure 1 mtr long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket, , suitable for operating between 30 degree centrigrade to + 55 degree centigrate, Fire Rating Class - 138. 80 Item No 28 : Supply only of stored pressure fire extinguiser ISI marked powder type Fire Extinguisher 4 KG capacity suitable for Class A, B, C Fire consisting with discharge hose and nozzle of welded cylinder, squeeze lever discharge valve fitted with pressure indicating guage, internal discharge tube, discharge nozzle suspension bracket conforming to IS : 15683 :2006 (old IS : 2878) duly charged with ISI Marked Mono Ammoniumphosphate base ABC powder conforming to IS : 14609 and pressurized with Nitrogen Gas, suitable for operating between 30 degree centrigrade to + 55 degree centigrate, Fire Rating Class - 1A & 13B 81 Item No 29 : Supply only of Fire bucket iron body red colour 10 L capacity for dry sand stored type ISI MarkedIS : 2546 :2006, complete all as specified and as directed. 82 Item No 30 : Supply only of Fire Extinguisher Mechanical Foam type ISI Marked Foam (AFFF) type Fire Extinguisher 9 ltrs capacity fitted with Forged Brass squeeze lever discharge valve, conforming to IS : 15683 :2006, complete with initial refill consisting of ISI Marked CO gas cartridge of 60 gms capacity conforming to IS 4947 and ISI Marked AFFF conforming to IS : 4989, suitable for operating between + 50 degree centrigrade , Fire Rating Class - 3A & 34B 83 Sewage Disposal 84 Item No 31 : M&L for DWCPE (SN8) pipes 180 OD/163 ID, laid and jointed complete complete all as specified and directed for the following internal dia of pipes. 85 Item No 32 : Construction of Conventional RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design mix in walls, Base slab, Baffle walls and roof slab including beams etc with Vent shaft, manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users conventional type. 86 Item No 33 : Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.6 M dia X 3.0 M effective depth. 87 SCHEDULE A(Schedule of credit)Schedule of Credite Rs 50001.00 (Minus) inserted by the MES.(Note : Credit amount shall be deducted manually to arrive net bid amount)
Contract Date: Jun 27, 2026 Contract Value : 10.28 Crore
Statutory Bodies & Commissions/Committees No of Bidders 10
Contract Date: Ref. Documents Contract Value : 6.17 Lakh
Boards / Undertakings / PSU No of Bidders 1
West Bengal View Result →
14.
Water Resources and Irrigation #10783464 Price Bid
Repair Maintenance Of Lwss Mangarh Under Division Tehsil Pacchad Distt. Sirmour Sh Supply, Errection Commissioning Of Pumping Machinery Centrifugal Pump Along With Allied Accessories Rm Lwss Mangarh Gp Mangarh In Tehsil Pacchad Distt. Sirmour Supply And Errection Of 60 Hp Induction Motor, Cables And Electrical Items-Supply, erection, testing & commissioning of submersible/ mono submersible pumping set of reputed make such as KSB/BS/ Johnston/Kirloshker/Worthington/Oswal/Sabar Brand conforming to latest relevent BIS code. The pump should be fittedwith free flow impellers of bronze /suitable alloy as per BIS 5659 or latestwith up to date ammendments suitable for raw/clear water having characterstics as mentioned in item 5(A) greased packed bearings& shell with wound stator on motor side & with shaft protection sleeve on pump sideensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to a submersiblesquirrel cage electric induction motor of Kirloskar/NGEF/Jyoti / Crompton/Havels make conforming to relevent BIS code with up to date ammendments totallydust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber chamber & grease packed lubricated bearings& provided with stainless steel thrust bearing plate to withstand non vertical loads withminimum wear & tear. It should also be fitted with a device to take up expansion ofwater with the heating of motor. The Pump set shuold include water level guard , errection clamps, tubler pie fited with outlet of tank with suitable arrangement welding/connecting to GI pipe (GI pipe for pump will be issued by the department free of cost) cable clips. & depth guage etc & suitable for operation of data given below. 2 Note:- Out of the 2 Nos. Pumps, 1 No. pump set will run and other will act as stanfd by:- 3 Total Head420 Mtr 4 Capacity of each pump set 5 LPS 5 Dia of Rising Main100 MM dia 6 Length of R/Main (in meter) 2280 Mtrs 7 Providing and Fixing double flanged cast steel sluice valve ofleader/KSB/ Kirlosker make of50 mm capable of with standing the normal seat presure as per IS 5312-1884P-1 with upto date ammedement forclass ASA-300 as per direction as per direction of Engineer-in-Charge including entire carriage of matrial up to all leads and lifts. 8 Providing and Fixing double flanged swing type cast steel refluxe valve ofBir/leader/KSB/Kirlosker/Kartar/Behl/Kirlosker//Kilbum/Gled/Kartar valve/ Fouress make 50 mm for rising main and capable of with standing the normal seat presure as per IS (API-6D) with upto date ammedement forclass ASA-300 as per direction as per direction of Engineer-in-Charge including entire carriage of matrial up to all leads and lifts. 9 Providing and fixing of suitable direct on line/oil immersed star delta starter/ATS/stator rotor stator of standard make such as MEI/Kilburn/Jyoti/Larson & Turbo/Havell/L& T standard confirming to BIS 8544-1979 latest with up to date amendment for squirrel cage slip ring motor (make to be specified by the tendrer) mounted on p[anel board with magnetic type over load release & dashpot, time lag under voltage release with initial oil filling. 10 Supplying, errection, testing commisioning of 60 HP AC induction motor make Marathon/Kirlosker/Bhel/Cropton/Jyoti/(STP type 2900 RPM 60HP) suitable to operation on 415 volts(+) (-) 10% 50 cycle/second 3 phase AC electric supply , the motor should be suitable to coupled with existing pump set complete with suitable coupling on common base plate including cost of nuts & bolts etc. as required complete in all respect. 11 Providing & fixing MS sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post suitable height and size ISA 40x40x6mm duly painted comparising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board should be subject approval of Engineer in charge. 12 Ammeture AC supply 100 mm dia circullar dial Auto electric/AE/IMP/ Havells make suitable range for above motor with selector switches confirming to BIS 1248 - (P-II) 1983 latest with up to date amendments. 13 Voltmeter AC supply 100 mm dia circullar dial Auto electric/AE/IMP/ Havells make suitable range for above motor with selector switches confirming to BIS 4064-1978 latest with up to date amendments. 14 ICTP switches with HRC fuse of Kilburn/Larsen & Turbo Satbdard/Siemen Havells make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with up to date amendments immidiately after the poer meter of HPSEB. 15 Busbar chamber having three copper bars of suitable rating for full length equal to width of board of three live phases and one copper bar of half rating of full length for netural confirming to BIS 8084-1976 and 1353-1985 read with 5578-1985 all latest with up to date amendments. 16 ACB/MCB oil circuit breaker of suitable capacity of kilburn/L&T/MEI/GEC standard make on incoming feeder for motor offered by the tendrer conforming to BIS 250-1985 latest with up to date amendments with initial oil filling whenever required & neutral linked under voltage release. 17 Three phse indiacating lamps complete with toggle switches for indivdual motors conforming to BIS 3452 pari 1 & II latest with upto date amendments. 18 Hour run meter of reputed make of four digit capacity confirming to BIS-722 (latest eddition)/ recommendations. 19 Providing and fixing of 95mm2 single core copper of L&T/Havels/Alcon/Eon/make including carriage of material up to all leads & lifts.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Himachal Pradesh View Result →
15.
Educational and Research Institute #10680797 Price Bid
supply of tool machinery goods- 1 Connecting screw driver 2 Neon tester 3 Insulated combination pliers 4 Electrician knife 5 Soldering Iron Changeable bits 6 De- soldering pump 7 Soldering Iron 8 Optical Drives 9 Post error debugging card 10 PCI slot Testing tool 11 Network Management Software 12 Wireless Network Adapter 13 Router 14 LAN Cards 15 WI-FI LAN Card 16 Power Meter 17 Media Convertor 18 24 port UTP jack panel 19 NVR 20 POE adapters kit 21 IP Camera Outdoor 22 Analog camera with dvr 23 SMPS 24 Blu-Ray driveand player Dell/ hp/ toshiba 25 Digital Camera 26 Network storage 27 Card Reader 28 SMPS Trainer kit 29 Foot rule steel tape 30 Steel Measuring Scale 31 MARKING KNIFE 32 Try Square 33 Bevel Square 34 Carpenter marking gauge 35 Carpenter mortise gauge 36 Hand Saw 37 Metal smoothing plane Anant 38 Screw driver 39 Contraction measuring scale 40 Wi Fi Router 41 Switch 42 DVD or Blu-Ray Writer 43 Network Rack 44 Screw Driver Set 45 Mini Dongle for Bluetooth devicesConnection 46 Patch Panel 47 Punching Tool 48 Tally 49 Box drawing instrument 50 Protractor celluloid 51 Scales plotting box wood 6 metric scales 52 Set square transparent 53 Set square celluloid 54 T-Square 55 Template- Architects and builders 56 Telescopic Alidade 57 Levelling staff straight pieces 58 Transit Theodolite with stand with all accessories 59 Digital theodolite 60 Instrument for total station 61 DLP projector 62 First aid box 63 Screen for projector 64 Air conditioner 65 Document Camera Visualiser 66 Smart board-inter active board 67 Measuring Steel Tape 68 Combination Plier Insulated 69 Screw Driver Insulated 6mm X 150 mm 70 Electrician screw driver thin stem insulated handle 4mm X 100 mm 71 Heavy Duty Screw Driver insulated 72 Electrician Screw Driver thin stem insulated handle 73 Punch Centre 74 Knife Double Bladed Electrician 75 Neon Tester 76 Steel Rule Graduated both in Metric and English Unit 77 Hammer cross peen with handle 78 Connecting screwdriver 79 Neon tester 500 V. 80 Screw Driver Set 81 Soldering iron 82 Electrician knife 83 Tweezers 84 Digital Multimeter 85 Soldering Iron Changeable bits 86 De- soldering pump electrical heated manual operators 87 Precision set of screw drivers 88 Precision set of screw drivers 89 Precision set of screw drivers 90 Tweezers Bend tip 91 Steel measuring tape 92 Tools maker vice 93 Crimping tool pliers 94 Magneto spanner set 95 File flat second cut 96 File flat smooth 97 Plier - Flat Nose 98 Round Nose pliers 99 Hammer ball pen 100 Allen key set Hexagonal set of9 101 Tubular box spanner set of 6Nos 102 Magnifying lenses 103 Continuity tester 104 Hacksaw frame adjustable 105 Chisel Cold Flat 106 Hand Drill Machine Electric with Hammer Action 107 Bench Vice 108 Bench Vice 50 mm 109 DC Regulated Variable Programmable DC Power Supply 110 LCR meter Digital Handheld 111 Analog multimeter 112 Clamp meter 113 Dimmer starter 114 Autotransformer 115 Milli Ammeter AC 116 Op Amp trainer 117 Digital IC Trainer 118 Digital IC Tester 119 Digital and Analog Bread Board Trainer 120 POWER ELECTRONICS TRAINER with at least 6 nos of onboard applications 121 Electronic circuit simulation software with 6 user licenses 122 Different types of electronic and electrical cables connectors sockets terminations. 123 DSO colour 124 PAM PPM PWM trainer kit 125 AMFM Commercial radio receivers 126 Sensor trainer kit containing Various sensors like Thermocouple RTD Thermocouple  load cell strain gauge LVDT smoke sensors speed sensor Limit Switch Photo sensors Optocouplor Proximity Sensor 127 Fiber optic communication trainer 128 Seven segment DPM 129 LCD based DPM 130 SMPS of different make 131 UPS trainer 132 Mobile phone Trainer 133 Cell phone power source with charger chords for different cell phones 134 LCD TV Trainer kit 135 LCD TV 136 LED TV Trainer kit 137 LED TV 138 Home theatre system 139 Solar Training Kit Simulator 140 LED lighting system 141 Trammel 142 Steel Rule with metric British graduation 143 Compressor unit 144 Try Square 145 Pocker. 146 Caliper inside spring type 147 Mallet. 148 Caliper hermaphrodite spring type 149 Carrier for mounting components such as PB relay boxes. 150 Caliper outside spring type 151 Aviation Snips straight Cut 152 Cut section model for pneumatic components 153 Divider spring type 154 Planishing hammer. 155 Scriber 156 Centre Punch 157 Screw driver 158 Depthmicrometer. 0-25 mm 159 Stake grooving. 160 Hammer ball peen With handle 161 Comparators Gauge - Dial Indication with Stand and Bracket 162 Hammer ball peen With handle. 163 File flat - second cut 164 Engineer s try square knife- edge 165 File flat smooth 166 File half round second cut 150 mm 167 Vernier Bevel protector 168 Carbide Wear Block 169 Carbide Wear Block 170 Dot punch 171 Spirit Level metal Type - 2 172 Arm strong type tool bit holder 173 Combination Set 174 Arm strong type tool bit holder 175 Arm strong type tool bit holder 176 Stillson wrenches 177 Micrometer inside with extension rods 178 Vernier caliper 179 Adjustable pipe chain tonge to take pipes 180 Adjustable spanner 181 Screw pitch gauge Metric 182 Surface plateC.IGranite with Stand and Cover 183 Marking table Mild steel 184 Universal scribing block 185 V-Block pair with clamps 186 Punch letter set 187 Portable hand drill Electric 188 File knife edge smooth 189 File feather edge smooth 190 File triangular smooth 191 File round second cut 192 File square second cut 193 File flat second cut safe edge 194 File half round second cut 195 File round bastard. 196 File hand second cut 197 File card 198 Oil Can 199 Wooden handle forged Soldering Iron copper bit 200 Blow Lamp 0.50 liters. 201 Spanner adjustable 202 Double Ended tubular Box spanner set with Tommy bar 203 Glass magnifying 204 Clamp C 205 Hand Reamer set Tapar pin straight flute 206 Machine Reamer parallel Helical flute 207 Scraper flat 208 Scraper triangular 209 Scraper half round 210 Pipe wrench 211 Adjustable pipe die set BSP 212 Machine vice - Swivel Base 213 Machine vice - Swivel Base. 214 Sleeve drill Morse 215 Vice bench 216 Wing compass 217 Power tools for fastening 218 Different Profile gauges Plate type - For demonstration 219 Knurling tool Diamond 220 Knurling tool straight 221 Knurling tool Diagonal 222 Indexable boring bar with inserts 223 Machine maintenance mannual for Lathe Pedestal grinder Drill machine Power saw 224 Temperature gauge 225 Dowel pin straight 226 Standard Tap screws 227 Lapping plate 228 Caps screws 229 Drill gauges 230 Cast Iron Globe Valve Flanged type 231 C.I. Sluice Gate valve flanged type 232 Stop cock 233 Slip-on Forged steel Flange 234 Pipe threading die with handle 235 Pulleys for V-belt or Flat belt 236 V-belt and Flat belt 237 Packing gasket 238 Washer clutch keys jib cotter circlip 239 Bearing different types 240 Lifting sling 241 Bearing extractor 242 Pulley extractor 243 File half round bastard 244 REFRIGERATOR ( 365 LTR ) DOUBLE DOOR 245 GAS TANDOOR WITH SKEWER ROTI SET ( 12 SKEWERS ) COMMERCIAL 246 BAIN MARIE 2 PAN WELL 55.5 X 70 X 20 CM 247 CHINESE GAS BURNER DURA STEEL 60 X 24 X 30 248 SALAMANDER AVON REFRIGERATION 600 X 510 X 550 MM 249 ELECTRONIC GEYSER 25 LTR( HAVELLS, ADONIA )DIGITAL TYPE 250 DOUGH KNEADING MACHINE ( 5KG CAP )1000 WATT, STAND MIXER 251 WATER BOILER ( ELECTRICAL 15 LTR)2000 WATTS 252 MIXER CUM GRINDER FOOD PROCESSOR 1 NOX 1000 WATT,WITH 7 ACCESSORIES 253 WOK CHINESE KADAI 16 DIA METER 254 PRESSURE COOKER ( 5 LTR ) CAP 255 EGG CUTTER STAINLESS STEEL 256 STEAK HAMMER ALUMINUM 257 MS CUPBOARD INTERIO 2 DOOR WITH 3 SELVES 7 X 3 X 3 258 HAND BLENDER 250 WATT 259 SIZZLER PLATES ( 17-18 DIA) HEAVY FINE QUALITY 260 COFFEE URNS , ( 40 CUP CAPACITY) 261 CHINESE CHOPPER 262 MS CHOPPER 600WATT 263 KITCHEN KNIFE, BIG CARTINI 8 BLADE 264 VEGETABLE KNIFE 13 CM BLADE, MEYER CERAMIC KNIFE 265 BREAD KNIFE 8 BLADE 266 PASTA MACHINE , 150 WATT 267 WATER PURIFIER REVERSE OSMOSIS 6.5 LTS UV + UF 268 SODA MAKER MACHINE HEAVY DUTY INDUSTRIAL MODEL KVR - 8 FLAVOR 269 ESPRESSO MACHINE COFFEE GRINDER 1300 WATT 270 MINIBAR FRIDGE 271 LED 42” HD DISPLAY 272 MUSIC SYSTEM WITH DVD PLAYERS CONCEALED SPEAKER, 5.1 CHANNEL 273 ELECTRIC OVEN 20 LTRS (IFB, WONDER CHEF,HAVELLS) 274 DISPLAY FOOD CABINET OSHAM SLIDING DOOR ,814X 641 X 831 MM W X D X H 275 ROOM SERVICE TROLLEY HOME CENTRE MONTOYA TYPE 276 CARAFE BOROSIL SMALL WITH STRAINERS, 350 ML 277 CARAFE BOROSIL LARGE WITH STRAINERS , 700ML 278 SOUP FLASK TERMOSTEEL ( 500 ML ) 279 WATER FLASK THERMOSTEEL FLIP LID FLASK 1000ML SILVER 280 PASTA TROLLEY GOLDEN LINE 4 CASTOR WHEEL 281 EPABX SYSTEM + AVS MACHINE S- TECH CS432, 4 MAIN TRUNK LINES & 32 EXTENSION 282 SAFE DEPOSIT LOCKER / FORTE 40 BIOMETRIC SAFE 283 UMBRELLAS , CITIZEN 3 FOLD 284 STEEL CUPBOARD WITH UNBREAKABLE GLASS , INTERIO 4 SHELVES 7.5 X 3 X 2.5 285 FRIDGE WITH CABINET 275 LTR 286 VACUUM CLEANER WET & DRY 287 WASHING MACHINE 8KG FULLY AUTOMATIC 5 X 1400 RPM , INBUILT HEATER 288 WATER HEATER 25 LTRS HSE-SES , 2000 WATT 289 CARPET EXTRACTOR, CARPET CLEANER MACHINE 1100 , W PRO E X 25 290 HIGH PRESSURE JET CLEANER , KK PWIN 165 1800 WATT , 165 BAR 291 LUGGAGE RACK MINT WOOD H 27.5 X W 28.5 X D 12.8 292 HEAVY BOTTOM PAN 10 LTR NON STICK CANEROLI 40 CM 293 COOKER ( 2 LTR ) CLASSICS 2L ALUMINUM 294 MANDOLIN GRATER ADJUSTABLE SS 4 BLADES WITH HANDLE 295 PROBE THERMOMETER ( 75 - 100 DEGREE CELCIUS ) ST 9283B LCD , DIGITAL MULTISTEM THERMOMETER 296 CAKE STAND ( SS ) 13 TOP 297 HEAT PROOF GLOVES GRIPWELL KELVES PALM LEATHER HEAT RESISTANT GLOVES 298 GRINDING STONE FINE GRINDER STONE 10 299 PIZZA CUTTER STAINLESS STEEL 300 COOKIE CUTTER ( 5 SHAPES ) ALLAMWAR 12 PCS STAINLESS STEEL CUTTER SET 301 SANDWICH GRILLER / TOASTER SW X 400 700 WATT ( 302 JUICER MACHINE PHILIPS HR 1863/20 , 2 LTR 303 ROLLING BASE WOODEN 10 304 FRYING PAN NON STICK GRANITE FRY PAN ( 280 MM) BLACK 305 FRYING PAN LARGE NON STICK FRY PAN 240 MM0 306 CLEVER STAINLESS STEEL 2 IN 1 VEGETABLE SCISSORS 307 Steel rule 308 Outside spring caliper 309 Inside spring caliper 310 Hermaphrodite caliper 311 Divider spring 312 Centre Punch 313 Hammer 314 Cold chisel flat 315 File flat bastard 316 File flat 317 File flat smooth 318 Screw Driver 319 Scribing blockuniversal 320 Screw driver heavy duty 321 Spindle blade screw driver 322 Solid parallels in pairs different sizes in Metric 323 Oil stone 324 Punch letter set 325 Punch number set 326 Drill Chuck 327 File Half round 328 File triangular smooth 329 Reamer 330 Reamer adjustable 331 Tool bits holder Armstrong R.H. 332 Table chuck 333 Machine vice 334 Compound angle vice standard sine 335 Universal Machine Vice 336 Shaper tool holder turret type to suit the machine 337 Base chuck forslotter to suit the machine 338 Milling Cutter Side and face cutter 339 Milling Cutter Side and face cutter Adison 340 Milling Cutter Adison 341 Milling Cutter -Side and face cutter adison 342 Milling Cutter - Double Angle Unequal. adison 343 Milling Cutter - Double Angle Unequal. adison 344 Milling Cutter - Single Angle.. adison 345 Milling Cutter - Slitting Saw Cutter adison 346 Milling Cutter - Slitting Saw Cutter. adison 347 Milling Cutter - Shell End Mill.Parallel Shank end mills adison 348 Milling Cutter - Parallel Shank end mills. adison 349 Milling Cutter -mills. Parallel Shank end mills.. adison 350 Milling Cutter - Parallel Shank end mills… adison 351 Milling Cutter - Parallel Shank end mills.... adison 352 Milling Cutter - T Slot Cutter with Parallel Shank adison 353 Micrometer outside. 354 Micrometer depth gauge 355 Digital micrometer 356 Vernier Caliper 357 Direct reading vernier caliper 358 Combination set 359 Vernier bevel protractor 360 Telescopic gauge 361 Centre punch 362 Divider spring joint 363 Caliper odd leg spring joint 364 Wrench adjustable 365 Spanner double ended 366 Pipe wrench 367 Plumbing hammer weight 368 Four way reversible valve 369 Tape measuringgraduation in mm 370 Voltmeter ACDC portable precision grade Digital Panel board type 371 Rule steel 372 Drawing Board 373 Easel a Type stand 374 Hack Saw with Frame 375 Chisel Knife 376 Chisel Knife- 8mm 377 Chisel Knife- 10mm 378 Chisel Knife 20mm 379 Chisel Knife- 30mm 380 Diamond Glazier Knife 381 Paint Tin Opener 382 Shave Huck Knife 383 Glider Knife 384 Paint Burner Acetylene Gas 385 Screw Driver 386 Mild Steel Panels 387 Sink Stainless steel 388 Suction feed spray gun with accessories 389 Infra red lamp 390 Pneumatic Polishing Machine with Pads 391 Pipe vice 392 Pipe wranch 10 393 Pipe wranch 16 394 flat file- smooth finish 395 Circuler cut file 396 Raft cut 397 Pipe dai set metric Inches 398 Gun Spray with Gravity Feed Cup with Complete accessories with Complete accessories 13ltr 399 Gun Spray with Gravity Feed Cup with Complete accessories.. 400 Conventional Spray Gun For Pressure Feed 401 Pencil Hardness Tester 402 Air Compressor single Phase 1 HP 403 File - Flat - Bastard 404 File - Flat - Safe Edge 405 Cooling tower 406 File flat roughdouble cut 407 File half round fine double cut 408 File round finedouble cut 409 File flat fine double cut 410 File square finedouble cut 411 File triangular fine double cut 412 Try square 413 Divider spring joint 414 Caliper spring joint in side 415 Caliper odd legspring joint 416 Hammer ball pane 417 Cold Chisel flat and cross cut 418 Engineers rule 419 Tape measuring 420 Pliers flat nose 421 Line tester 422 Tweezers 423 Oil can 424 Surface Gauge universal 425 Bench vice 426 Hack saw tubular metal frame adjustable 427 Snip sheet metal straight nose 428 Snip sheet metal curved nose 429 Wooden mallet Nylon mallet 430 Round Punch 6mm 431 Round Punch 432 Round Punch 4mm 433 Screw driver plastic handle 434 Screw driver plastic handle Flat tip 435 Philips screw driver 436 Soldering ironexchangeable copper tip 437 Knife foldedstainless steel - 438 Tenon saw 439 Firmer chisel 440 Fire buckets 441 Quick couplesprocess tube adopter 442 Flaring tool set single type for tube. 443 Swaging tool punch type set of size for tube. external type for copper tube 444 Pipe cutter miniature for copper tube 445 Pinch of tool for copper tube 446 Ratchet spanner 447 Capillary plug gauge 448 Piercing pliers 449 Spanner double ended 450 Wrench adjustable 451 Wrench adjustable length 250mm 452 Valve key handleTreated as consumable 453 Hollo Punch hole for cutting gasket 454 Scissor gasketcutting stainless steel 455 L-Allen key 456 T-Allen key set 457 Pipe cutter withbuilt in reamer and space cutter for copper tube 458 Lapping plate 459 Hammer ball peen 460 Tap set withmatching drills 461 Tap set withmatching drills V to 462 Piercing Valve 463 Feeler gauge 464 Tape measuringgraduation in mm 465 Ammeter ACDCportable precision grade Digital Panel board type 466 Multi meter digital type 467 C.R.O Single beam 468 C.R.O Dual trace Double beam 469 A.F.O Oscillators 470 Pressure gauge 471 Compound gauge Digital type 472 Electronic leak detector 473 Sling psychro meter mounted on aluminum back 474 Stop watch 475 Multi meter 476 Sensor thermometer digital 477 filler guage 478 Wire gauge 479 Dial thermometer 480 Compressors testers for small hermetic compressors 481 Precision set of T5 T6 T7 screwdrivers- 482 Jacket stripper Coring tool for 500 series cable 483 Center conductor cleaner 484 Universal drop trimmer for RG 6/11 cables 485 F - connector tool for RG 6/11 cables 486 F connector compression tool for RG 6/11 cables 487 Solar Training Kit Simulator With built in meters for DCV DCA AC Multifunction Meter for ACI ACV Power Frequency Protection Circuits BS-10 terminals formaking the connection Single Dual axis tracking system Charge Controller PWM based MPPT Charging Stage Bulk Absorptions and Float 488 LED lighting system Measurement of Power Voltage Current Power Factor and Light output performance of different lighting products like LED CFL at variable inputvoltages 0 to 245V variable AC 489 PLC Systems with digital IP OP modules and software 6 Digital Inputs 24V DC. 4 Digital Outputs 24V DC 2K Words of memory 256 words of register. Powerful features like built in Floating Point Sub Routines etc.One RS232 C communication facility for PC interface. Three channels can be configured as follows Pulse width modulation output or Pulse train outputor High speed counter input. 490 Electronic Pneumatics Trainer kit 491 CRO dual trace 20 MHZ ( Component testing facilities ) 492 Steel wire Brush 50mmx150mm 493 carborundum 15 x 5 x 4 cm smooth 494 Straight edge gauge 2 ft. 495 Straight edge gauge 4 ft. 496 Surface gauge with dial test indicator plunger type i.e. 0.01 mm 497 Tachometer Counting type 498 Taps and Dies complete sets 5 types 499 Taps and wrenches - Metric 500 Temperature gauge 0- 100 deg c 501 Thread pitch gauge metric BSW 502 Timing lighter 503 Universal puller for removing pulleys bearings 504 V Block 75 x 38 mm pair with Clamps 505 Vacuum gauge to read 0 to 760 mm of Hg 506 Valve Lifter 507 Valve spring compressor universal 508 vernier caliper 0-300 mm with least count 0.02mm 509 Vice grip pliers 510 Voltmeter 50VDC 511 Hand Shear Universal 250mm 512 Solid Parallels in pairs Different size in Metric 513 Spanner Clyburn 15 514 Spanner T. flocks for 515 Spark lighter 516 Spark plug spanner 14mm x 18mm x Size 517 Spirit level 2V 250 05 518 Spring tension tester 519 Stake grooving. 520 Spanners socket with speed handle T-bar ratchet and universal upto 32 mm set of 28 pieces with box 521 Steel tool box with lock and key folding type 400x200x150 mm 522 Wire cutter and stripper 523 Car Jet washer with standard accessories 524 Chaser hard WV 9 to 40 T.P.I. set of 11 external. 525 Chaser hand WW 9 to 40 T.P.I. set of 11 internal. 526 Chisel 10 cm flat 527 Chisels cross cut 200 mm X 6mm 528 Circlip pliers Expanding and contracting type 15cm and 20cm each 529 Clamps C 100mm 530 Clamps C 150mm 531 Clamps C 200mm 532 Compression testing gauge suitable for diesel Engine 533 Connecting rod alignment fixture 534 Copper bit soldering iron 0.25 Kg 535 Cylinder bore gauge capacity 20 to 160 mm 536 DC Ohmmeter 0 to 300 Ohms mid scales at 20 Ohms 537 Depth micrometer 0- 25mm 538 Dial gauge type 1 Gr. A complete with clamping devices and stand 539 Dividers 15 cm Spring 540 Drift Punch Copper 15 Cm 541 Drift copper 10 x 15 12 mm 542 Drill point angle gauge 543 Drill twist 1.5 mm to 15 mm various sizes by 0.5 mm 544 230 V 25 watts Electric Soldering Iron 230 V 60 watts 545 Electric testing screw driver 546 Engineers square 15 cm. Blade 547 Engineers stethoscope 548 Equipment puncture in box 549 File flat 20 cm bastard 550 File half round 20 cm second cut 551 File Square 20 cm second cut 552 Files assorted sizes and types including safe edge file 20 Nos 553 Glow plug tester 554 Granite surface plate 1600 x 1000 with stand and cover 555 Grease Gun 556 Grover- 34mm. 557 6mm Grover 558 Growler 559 Hacksaw frame adjustable 20-30 cm 560 Hammer Chipping 0.25 Kg 561 Hammer copper 1 Kg with handle 562 Hammer Mallet 563 Hammer Plastic 564 Hand operated crimping tool i for crimping up to 4mm and ii for crimping up to 10mm 565 Hand reamers adjustable 10.5 to 11.25 mm 11.25 to 12.75 mm 12.75 to 14.25 mm and 14.25 to 15.75 mm 566 Hand vice 37 mm 567 High rate discharge tester cell tester 568 Left cut snips 250mm 569 Magneto spanner set with 8 spanners 570 Magnifying glass 75mm 571 Marking out table 90X60X90 cm 572 Multi Scan Tool 573 Multimeter digital 574 Oil Stone 15 cm x 5 cm x 2.5 cm 575 Oscilloscope 20MHz 576 Outside micrometer 0 to 25 mm 577 Outside micrometer 25 to 50 mm 578 Pat melting 579 Philips Screw Driver set of 5 pieces 100 mm to 300 mm 580 Pipe cutting tool 581 Pipe flaring tool 582 Piston Ring groove cleaner 583 Pliers side cutting 15 cm 584 Poker 585 Portable oil monitoring Indicator 586 Power Supply 0-12 v lamp 587 Radiator pressure cap 588 Rear axle assembly- gear box steering box assembly of the diesel engine 589 Right cut snips 250mm 590 Rivet sets snap and Dolly combined 3mm 4mm 6mm 591 Scriber 15 cm 592 Scriber with scribing black universal 593 Set of stock and dies - UNC UNF and metric 594 Shear Tin Mans 450 mm x 600mm 595 Sheet Metal Gauge 596 Soldering Copper Hatchet type 500gms 597 Sher Tinmans 300mm 598 Shovel 599 Ammeter 300A 60A DC with external shunt 600 Angle plate adjustable 250x150x175 601 Angle plate size 200x100x200mm 602 Arbor press hand operated 2 ton capacity 603 Auto Electrical test bench 604 Battery charger 605 Belt Tensioner gauge 606 Spanner ring set of 12 metric sizes 6 to 32 mm. 607 Blow Lamp 1 litre 608 AC alternator slip ring puller 609 Allen Key set of 12 2mm to 14mm pieces 610 Air blow gun with standard accessories 611 Alternator for tractor different type Mico , Bosch, tux 612 Hands file 20 cm. Second cut flat 613 Caliper outside spring joint 614 Caliper inside spring joint 615 Caliper odd-leg firm joint 616 Steel Rule 617 Scriber 618 Hammer ball peen 619 Centre punch 620 Prick punch 621 Divider spring joint 622 Safety goggles clear glass Good quality 623 Marking table CI 624 Bench vice 125 mm jaw 625 V - Block 626 Pliers flat nose 627 Micrometer Outside 628 Micrometer Inside 629 Vernier Bevel Protractor 630 Vernier Micrometer 631 Universal Dial Test Indicator - Plunger Type 632 Vernier Height Gauge 633 Plain Ring and Plug Gauge 634 Drill Twist Set 635 Reamer machine 636 Combination Drill Centre Drill 637 Tool Bit assorted sizes on holder 638 Chalk Board on mobile stand 639 Desk 640 Hand Chaser 641 Hand Chaser 642 Revolving Centrer to suit Lathe tailstock 643 Tool Cemented carbide assorted shaped External for steel turning 644 Machine Chase 645 Coventry Die head 646 Lathe Mandrels Diff. Types 647 Coventry Type Die Head Self opening 648 Stainless steel rule 649 Hack saw frame 650 File half round 651 File flat 652 Try square 653 Earth clamp 654 Electrode holder ESAB 655 Oxygen Gas Pressure regulator double stage ESAB 656 Acetylene Gas Pressure ESAB 657 CO2 Gas pressure regulator with flow meter ESAB 658 Argon Gas pressure regulator ESAB 659 First Aid box ESAB 660 Flash back arrester torch mounted ESAB 661 Flash back arrester cylinder mounted ESAB 662 Screw Driver 663 Screw Driver 664 Terminal screw Driver 665 Hammer Ball peen 666 Neon tester pencil bit type 667 Small crimping tools assorted 668 Spanner set DE 669 Screw driver set set of 5 670 File half round 2nd cut 671 File round 2nd cut 672 Soldering iron TONY 673 Neon tester 674 Spade 675 Sickle 676 Khurpa 677 Kasola 678 Trifali 679 Zindra 680 Dori (Nylon rope) 681 Wheel hand hoe 682 pH meter 683 Electrical conductivity meter 684 Flame photometer 685 Spectrophotometer 686 Atomic absorption spectrophotometer 687 Shaking apparatus 688 Distillation unit 689 Ammonia distillation unit (with heaters) 690 Gas connection 691 Sampling tools (augers) 692 Refrigerator 693 Gas cylinders with regulators 694 Gas cylinders with regulators 695 Gas cylinders with regulators 696 Incubator (with temperature control) 697 Infrared soil moisture estimation unit 698 Electric oven 699 Soil cores 700 Soil infiltratormeter 701 GPS system with mobile phone 702 Table top centrifuge 703 Auto Titrator 704 Battery charger
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 6
17.
Rural Development #10648791 Price Bid
Precision Instruments Supply And Installation Of Precision Instruments For The Upgradation Of Priority Gitis Across Uttarakhand , Supply And Installation Of The Following Items As Per The Delivery Schedule Stipulated In The Rfq Document , Bevel Gauge , Bore Gauge , Bore Gauge With Dial Indicator , Caliper Hermaphrodite Spring Type , Caliper Inside 15 Cm Spring , Caliper Inside Spring , Caliper Inside Spring Joint , Caliper Inside Spring Type , Caliper Odd-Leg Firm Joint , Caliper Outside , Caliper Outside Spring Joint , Caliper Outside Spring Type , Caliper Spring Joint In Side , Caliper Transfer Inside , Caliper, Odd Leg, Spring Joint , Calipers Outside 15 Cm Spring , Calipers Outside Spring , Calliper Inside With Spring , Callipers Outside With Spring , Centre Gauge , Centre Gauge Com. , Centre Gauge-55° & 47.5° , Centre Gauge-60° , Combination Set-200 Mm , Combination Set-300 Mm , Comparators Gauge - Dial Indication With Stand And Bracket. , Cylinder Bore Gauge Capacity , Cylinder Bore Gauge Capacity 20 To 160 Mm , Depth Gauge Micrometer , Depth Micrometer , Depth Micrometer. 0-25 Mm , Dial Gauge Type 1 Gr. A ( Complete With Clamping Devices And With Magnetic Stand ) , Dial Test Indicator , Dial Test Indicator – Puppitast Type , Dial Test Indicator On Stand , Dial Test Indicator Plunger Type-Range , Dial Test Indicator-Lever Type- Range , Dial Vernier Caliper , Dial Vernier Caliper With Metric , Dial Vernier Caliper. ( Universal Type ) , Different Profile Gauges ( Plate Type ) - For Demonstration , Digital Micrometer , Digital Micrometer Outside. , Digital Vernier Caliper-Measure Range-0-200 Mm. , Digital Vernier Caliper-Measure Range-0-300 Mm , Direct Reading Vernier Caliper , Divider 150 Mm Spring Type , Divider Spring Joint , Divider Spring Type , Divider Spring-Size:150Mm , Divider Spring-Size:200Mm , Dividers 15 Cm Spring , Dividers Spring , Dividers With Spring , Dividers-Size:200Mm , Dividers-Size:250Mm , Engineer’S Square , Engineer’S Square 15 Cm. Blade , Engineers Rule , Engineers Square 15 Cm. Blade , Engineers Square-Size- 150 Mm4mm Thick , Engineers Square-Size- 700 Mm , Engineers Try Square ( Knife-Edge ) , Feeler Gauge 20 Blades ( Metric ) -Set Of 20 , Feeler Gauge 20 Blades ( Metric ) -Set Of 25 , Feeler Gauge Leaf Type, 26 Blades, Eng. & Metric , Feeler Gauge-Set Of 25 , Feeler Gauge-Set Of 26 , Gauge - Radius Set-1-7- & 7.5-15-Mm , Gauge - Radius Set-1Mm To 25 Mm , Gauge Blocks , Gauge Feeler , Gauge Feeler / Thickness , Gauge Plug , Gauge Screw Pitch , Gauge Slip Box , Gauge Snap Go And Not Go , Gauge Telescopic Set. , Gauge, Wire Imperial Stainless Steel Marked In Swg & Mm , Granite Surface Plate With Stand And Cover , Hermaphrodite Caliper , Inside Calliper , Inside Micrometer Range , Inside Micrometre , Inside Spring Caliper , Inside Spring Caliper-Size: 150 Mm , Level Spirit Wooden , Limit Plug Gauges-10Mm, 15Mm, 20Mm , Limit Plug Gauges-Size: 5 To 25 Mm , Magnetic Stand With Magnetic Base , Magnetic V-Block , Metric Screw Pitch Gauge-Range , Micrometer - Inside - , Micrometer - Outside -0-25 Mm , Micrometer - Outside -25-50 Mm , Micrometer Depth Gauge , Micrometer Inside With Extension Rods. , Micrometer Inside-Measuring Range:0-25Mm , Micrometer Inside-Measuring Range:25-50 Mm , Micrometer Outside , Micrometer Outside Measurement-Accumechanic , Micrometer Outside Measurement-Range ( Mm ) :0-25 Mm , Micrometer Outside-0-25 Mm , Micrometer Outside-25-50 Mm , Micrometer Outside-50-75 Mm , Micrometer Outside-Range ( Mm ) :50-75 Mm , Micrometer Outside-Range ( Mm ) :0-25 Mm , Micrometer Outside-Range ( Mm ) :75-100 Mm , Odd Leg Calliper , Optical Bevel Protractor , Out Side Micrometer-Measuring Range: Up To 25Mm , Outside Calliper , Outside Micrometer 0 To 25 Mm , Outside Micrometer 25 To 50 Mm , Outside Micrometer 50 To 75 Mm , Outside Micrometer 75 To 100 Mm , Outside Micrometer-With Ratchet Stop & Lock, Range ( Mm ) :0-25 Mm , Outside Micrometer-With Ratchet Stop & Lock. Range ( Mm ) :75-100 Mm , Outside Micrometre-With Ratchet Stop & Lock.Range ( Mm ) : 25-50 Mm , Outside Micrometre-With Ratchet Stop & Lock. Range ( Mm ) :50-75 Mm , Outside Micrometre-With Ratchet Stop & Lock; Type: Digital Type; Range ( Mm ) :0-25 Mm , Outside Spring Caliper-150 Mm , Outside Spring Caliper-200 Mm , Pin Gauge Set , Plain Ring And Plug Gauge , Plastic Feeler Gauges-Set Of 25 , Plug Gauge , Protractor With Blade , Radius Gauge , Radius Gauge Leaf Type , Ring Gauges , Rule Steel-24 Inches , Rule Steel-300Mm , Screw Pitch Gauge , Screw Pitch Gauge For Metric, Standard & Fine Pitches , Screw Pitch Gauge Metric , Screw Pitch Gauge To Cover Above Threads , Screw Thread Micrometer Interchangeable , Screw Thread Micrometer With Interchangeable. Pitch Anvils For Checking Metric Threads 60. , Scriber , Scriber With Scribing Black Universal-Height: 300Mm , Scribing Block Universal , Sheet Metal Gauge-28 Blades , Sheet Metal Gauge-Size: Swg1 To Swg 36 , Sine Bar 200 Mm , Sine Bar With Centers , Sine Bar With Stopper Plate , Sine Bar-Size-125Mm , Sine Bar-Size-200Mm , Slip Gauge , Slip Gauge As Johnson Metric Set. , Slip Gauge Box ( Workshop Grade ) - , Slip Gauge Box ( Workshop Grade ) - 87 Pieces Per Set , Slip Gauge Metric Set , Spirit Level 2 V 250, 05 Metre , Spirit Level Metal Type - 2 , Spirit Level Precision Metallic-Accumechanic , Spirit Level Precision Metallic-Base Length: 200 Mm , Spirit Level-Length: 150 Mm , Spirit Level-Length: 300 Mm , Spring Scale , Sprit Level , Stainless Steel Rule , Standard Wire Gauge , Steel Measuring Scale , Steel Rule 15 Cm Inch And Metric , Steel Rule 30 Cm Inch And Metric , Steel Rule Graduated Both In Metric And British Unit , Steel Rule Graduated Both In Metric And English Unit , Steel Rule With Metric & British Graduation , Steel Rule-300Mm , Steel Rule-60 Cm , Steel Rule-Size: 150 Mm , Steel Square , Straight Edge , Straight Edge Gauge-2 Feet , Straight Edge Gauge-4Feet , Straight Edge Steel- 500 Mm , Straight Edge Steel-1000 Mm , Straight Edge Steel-300-500 Mm , Straight Edge-Single Beveled-Size , Surface Gauge Universal , Taper Gauge , Telescopic Gauge- 8-150Mm , Telescopic Gauges , Thread Pitch Gauge Metric , Thread Pitch Gauge Metric, Bsw , Try Square Hardened Blade , Try Square-Size:150 Mm , Try Square-Size:200 Mm , Universal Dial Test Indicator , Universal Dial Test Indicator - Plunger Type , Universal Scribing Block. , Universal Surface Gauge , Universal Vernier Caliper-Range , Universal Weld Measuring Gauge , V- Block , V Block 75 X 38 Mm Pair With Clamps-75 X 38 Mm , V Block Size: 150X100x100mm Pair With Clamps , V’ Block Pair With Clamps-Size: 150X100x100mm , V-Block Pair With Clamps-Size: 150X100x100mm , V-Block-Approx , Vernier Bevel Protractor , Vernier Bevel Protractor Blade With Acute Angle Attachment , Vernier Bevel Protractor Blade With Acute Angle Attachment , Vernier Caliper 0-300 Mm With Least Count 0.02Mm , Vernier Caliper Outside, Inside And Depth , Vernier Caliper-Measuring Range:0-150 Mm , Vernier Caliper-Measuring Range:0-200 Mm , Vernier Caliper-Measuring Range:0-300 Mm , Vernier Caliper-Range , Vernier Calliper , Vernier Calliper 0-300 Mm With Least Count 0.02 Mm , Vernier Gear Tooth Caliper , Vernier Height Gauge-Measuring Range:0-250 Mm , Vernier Height Gauges-Measuring Range:0-300 Mm , Vernier Hight Gauge , Vernier Micrometer-Range ( Mm ) :0-25 Mm , Vernier Micrometer-Range ( Mm ) :0-1 Inch , Vernier Micrometer-Range ( Mm ) :25-50 Mm , Wing Compass , Wing Compass. , Wire Gauge , Wire Gauge ( Metric ) -Circular , Wire Gauge ( Metric ) -Disk Type , Wire Gauge ( Metric ) , Wire Gauge, Metric Standard. , Wire Gauges , Wire Type Strain Guage ( Load Cell / Cantilever Bear )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttarakhand View Result →
18.
Rural Development #10604732 Price Bid
Supplying And Erecting Led Street Light ( Hightmast ) At Lonwadi Tal . Niphad Dist . Nashik , 8-3-1 Supplying And Erecting 12 . 5 M ( Clear Hight ) Hight Mast ( Top-150Mm , Bottom-360Mm ) With Lowering And Raising Motorizedunit , Lantern Carriage Assembly Suitable For Max . 6 Nos . Luminariesand Its Control Gear Box , Lightning Finial , Arrangement Forf . Xingavation Light And Foundation Bolts On Provided Foundation As Pespecification No . Oh-Pl / Hm ( Excluding Luminries And Cg , 16-3-10 Providing And Casting Of M-20 Grade Reinforced Cement Concrete ( Rcc ) Foundation Suitable For 11M And 12 . 5 M Hight Octogonal / Conical G . I . Pole Considring The Safe Soil Bearing Capacity At Site As 10T / Sqm At 1 . 5M Depth Including Supply Of Steel , Concrete , Excavation And Fixing Provided Nut Bolts With Help Of Temples As Per Desing In An Approved Manner , 8-3-32 Supplying And Erecting Outdoor Stand Mounted Feeder Pillar For High Mast Of The Same Manufacture With 32A Tpn Mcb Incomer , Single Dial Timer Switch , 25 A Tp Conctactor For Automatic Switching Of Luminaries 2 No 9A Constactors And Raise / Lower Push Button , And Provision For Temination Of Incoming Minimum 35 Sq . Mm And Outgoing Minium 16 And 2 . 5 Sq . Mm Cables Complete Erected Inmin . 14 Guage Crca Sheet Box With Supporting , 9-1-4 Providing Pipe Type Earthing With 40Mm . Dia . G . I . Pipe Or 20Mm Dia . G . I . Rod Complete With All Materials As Per Speficiation No . Ea-Ep , 1-4-1 Supplying , Erecting Maines With Isi Mark Pvc Unarmoured Cable 2X2 . 5 Sq 1100 V Grade Aluminum Pvc Insulated And Pvc Sheated Wires G . I . Bearer Wire No . 8 , 7-3-9 Supplying And Erecting Frp Box Of Six=Ze 250Mm X 200Mm X 100Mm , 2 . 7Mm Thick Complete On Pole As Per Specification No . Cb-Sb , 7-1-4 Supplying Erecting And Terminating Pvc Armoured Cable 2 Core 10Sq Mm Aluminium Conductor With Continuous 5 . 48Sq . Mm ( 12Swg ) G . I . Earth Wire Complete Erected With Glands And Lugs , On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No . Cb-Lt / Al , 16-1-1 Making The Trench In Soft Soil Of Suitable Width And Depth As Per Is For Laying Provided L . T Cable Up To 25 Sq . Mm . Complete . As Per Specification No . Cw-Exn-Ctr , Supplying And Erecting Iron , Sheet Metal Work Consisting Of Crca Sheet , Vatious Sections Of Iron , Plates , Chequered Plates , Rods , Bars Ms Pipe Etc For Panel Board Or Any Other Purpose Complete With Bening Cutting Drilling And Welding Complete Ere4cted At The Position With Necessary Material Duly Painted With One To Match The Switches Or As Per Direction By The Authority ( 6-1-19 ) , 2-9-18 Supplying And Erecting Led Flood Light Fitting 120 W Including Lamp With Pf> . 95 , Class Ip 65 Or Above Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium As Alloy And Heat Sink Extrded Alluminum Complete Per Specification No . Fg-Odp / Fl
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
19.
Rural Development #10567841 Price Bid
Providing Erecting Various Different Electrical Material For Street-Light N Other At Gp ( Gp Fund ) , Providing And Supplying various electronic Material For Street Light At Grampanchayat Lonikalbhor , Supplying And Erecting Modulartype Switch6a / 10A Isimark Approved Make Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Making Cement Concrete Foundation Including Excavation ( 60 X 60 X 150 ) Cm Deep In 1:3:6 Cement Concrete 20 X 25 Mm Stone Metal, ( 45 X 45 X 45 ) Cm / 45 Cm Dia. X 45 Cm Height Plinth Duly Plastered, With Necessary Curing And Finishing Complete. ( Above 6 M To 9 M Poles ) , Supplying And Erecting Steel Tubular Swaged Pole 139.7 X 114.3 X 88.9 Mm. Dia With 4.5X3.65X3.25 Mm Thickness ( 4 + 1.5 + 1.5M ) Length Respectively And Total 7 M Long With Pole Cap, , Supplying And Erecting Steel Tubular Swaged Pole 139.7 X 114.3 X 88.9 Mm. Dia With 4.5X3.65X3.25 Mm Thickness ( 4.5 + 1.75 + 1.75M ) Length Respectively And Total 8 M Long With Pole Cap, , Supplying And Erecting Steel Tubular Swaged Pole 165.1 X 139.7 X 114.3 Mm Dia With 4.5 X 4.5 X 3.65 Mm. Thickness ( 5 + 2.5 + 2.5 M ) Length Respectively And Total 10 M Long With Pole Cap , 9M ( Clear Height ) Fixed Typr High Mast ( Top-100Mm, Bottom-200Mm Withexagonal / Round Bracke And Foundation Bolts Suitable For Max. 4 Nos Flood Light Fixtures , Supplying And Erecting Street Light Bracket For Erection Of Single Fitting On Tubular Welded Pole With 40 Mm. Dia 1.0 M Long “B” Grade G.I. Pipe Along With Pole Cap Of 125Mm Dia 600 Mm Long Duly Welded As Per Specification No. Fg-Bkt / Bpc , Supplying, Tpmcb 40A To 63A In Provided Distribution Board , Supplying, Erecting & Marking Dpmcb 40A To 63A, B- Series ( For Lighting ) In Provided Distribution Boardas Per Specification No. Swswr / Mcb , Dp Switch Isi Mark , Supplying And Erecting Programmable Digital Almanactimer Microcontroller Based With Real Time Clock To Operate On Derived Switching “On” & Switching “Off” Street Light As Per Daily Sunset And Sunrise Respectively , 1.25 Mm Crca Sheet Metal Enclosures With 20A. , Supplying Pvc Insulated Pvc Round Sheathed 1.5 Sq.Mm ( 30 No. X 0.25 Mm Dia. ) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv , Supplying And Erecting Pvc Insulated Pvc Round Sheathed 2.5 Sq.Mm ( 50 No. X 0.25 Mm Dia. ) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv , Supplying And Erectingled Street Light Fitting Suitable For 26W To 36W Led Street Light, Including Lamp, With Pf > 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Alluminium Alloy And Heat Sink Bajaj Make Make Make , Supplying And Erecting Led Street Light Fitting Suitable For Above 40W To 48W Lamp, Including Lamp, With Pf > 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Nobajaj Make Make. Make Fgodf / Fls2. , Supplying And Erecting Led Street Light Fitting Suitable For 60W Lamp, Including Lamp, With Pf > 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete As Per Specification Bajaj Make Makemake No Fg Odf / Fls-2. , Supplying And Erecting Led Street Light Fitting Suitable For Above 70W- 75 Lamp, Including Lamp, With Pf > 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj Make Makemake No Fg-Odf / Fls2 , Supplying And Erectingled Street Light Fitting Suitable For 90 W Led Street Light, Including Lamp, With Pf > 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Alluminium Alloy And Heat Sinkbajaj Make Make . , Supplying And Erecting Led Street Light Fitting 100W, Including Lamp, With Pf > 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj Make Make No Fg-Odf / Fls-2. , Supplying And Erecting Led Street Light Fitting 120 W, Including Lamp, With Pf > 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj Make Make No Fg-Odf / Fls-2. , Supplying And Erecting Led Street Light Fitting 150 W, Including Lamp, With Pf > 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj Make Make No Fg-Odf / Fls-2 , Supplying And Erecting Led Flood Light Fitting Of 120W, Including Lamp, With Pf > 0.95, Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specificationbajaj Make Make No Fg Odf / Fls-2 , 2-5-17 Supplying And Erecting Led Flood Light Fitting Of 150W, Including Lamp, With Pf > 0.95, Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specificationbajaj Make Make No Fg-Odf / Fls-2 , 2-5-18 Supplying And Erecting Led Flood Light Fitting Of 150W, Including Lamp, With Pf > 0.95, Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj Make Makeno Fg-Odf / Fls-2 , Supplying And Erecting Street Light Bracket Made From 40 Mm. Dia ‘B’ Class G.I. Pipe, 0.6M. In Length Along With Pole Cap Of 300 Mm Length And 80 Mm Dia Duly Welded With Provided Leads As Per Specificationjno. Fg-Bkt / Bpc ( 2-9-2 ) , Single Arm Bracket , Double Arm Bracket , Supplying And Erecting Street Light Wall Bracket Made From 25 Mm. Dia ‘B’ Class G.I. Pipe 1.2 M In Total Length Complete As Per Specification No. Fg-Bkt / Wb ( 2-9-3 ) , Supplying & Layingpvc Armoured Cable 4Core 6Sq Mm , Supplying & Layingpvc Armoured Cable 4Core 10 Sq Mm7-1-15 , Supplying & Layingpvc Armoured Cable 2Core 10 Sq Mm , Supplying & Layingpvc Armoured Cable 2Core 6 Sq Mm , Supplying & Layingpvc Armoured Cable 4Core 16 Sq Mm , Supplying & Layingpvc Armoured Cable 4Core 25 Sq Mm , Supplying, Erecting & Marking Spmcb 6A To 32A, B- Series ( For Lighting ) , Supplying, Erecting & Marking Dpmcb 6 A To 32 A Bseries ( For Lighting ) , Supplying, Erecting & Marking Tpmcb 6 A To 32Amp In Provided Distribution Board , Supplying, Erecting & Marking Fpmcb 40A To 63A In Provided Distribution Board , Flexible Wire 1.5 Sq.Mm X 2 Core Copper , G.I Wire ( 08 Guage ) , G.I Wire ( 10 Guage ) , G.I Wire ( 06 Guage ) , Supplying And Erecting Mains With Isi Mark Wp2 X 2.5 Sq Mm. 1100 V. Grade Aluminium Pvc Insulated Pvc Sheathed Wires On G.I. Bearer Wire , Supplying And Erecting Mains With Isi Mark Wp2 X 10.00 Sq Mm. 1100 V. Grade Aluminium Pvc Insulated Pvc Sheathed Wires On G.I. Bearer Wire , 25 Amp, 32 Amp Three Phase L / T Contactor , Insulation Tape , Supplying And Laying ( Including Excavation Of Suitable Width & Depth Up To 90 Cm ) 50 Mm Outside Dia. Double Wall Corrugated Pipes ( Dwc ) Of Hdpe For Enclosing Cable Below Ground / Road Surface, To Required Depth Complete. , Light Poles Painting In Silver Colour , 26W Led Light To 100W Led Light Repairing , Old Pole Shifting, Rework And Foundation Work Per Pole Etc. , Driver For Out Door Led Fittings Upto 26W-45W , Driver For Out Door Led Fittings Upto 66W-75W , Driver For Out Door Led Fittings Upto 76W- 100W , Providing & Erecting 6 M High ( Clear Height ) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 130 Mm A / F, Top 70 Mm A / F On Provided Foundation As Per Specification Bajaj Make Make No. Oh- Pl / Opl , Providing & Erecting 7 M High ( Clear Height ) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 130 Mm A / F, Top 70 Mm A / F On Provided Foundation As Per Specificationbajaj Make Make No.Oh- Pl / Opl. , Providing & Erecting 9 M High ( Clear Height ) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 155 Mm A / F, Top 70 Mm A / F On Provided Foundation As Per Specification Bajaj Make Makeno. Oh- Pl / Opl , Providing & Erecting 10 M High ( Clear Height ) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 175 Mm A / F, Top 70 Mm A / F On Provided Foundation As Per Specification Bajaj Make Make No. Oh-Pl / Opl , Providing & Erecting 12 M High ( Clear Height ) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 240 Mm A / F, Top 90 Mm A / F On Provided Foundation As Per Specificationbajaj Make Make No. Oh-Pl / Opl , Service Wire 2.5 Sq.Mm Isi Mark 2 Core , Service Wire 6 Sq.Mm Isi Mark 2 Core , Service Wire 10 Sq.Mm Isi Mark 2 Core , Frp Box Of Size 300 X200 X125 Mm 2.7Mm Thickness , 12W Led Bulb , 14W Led Bulb , 18W Led Bulb , 16 Amp Kitkat Fuse , 63 Amp Kitkat Fuse , Procelain Reel , Retrofit T8 Led 18 / 20 Tube Light , Lamp Holder China Clay , Lamp Holder ( Pendent ) , Isi Mark G.I Pole B Grade 80 Mm Dia 6 Mtr Long With Pole Cap, Base Plate. , 1000W Halogen Set , Supplying & Erecting Street Light Control Panel Outdoor Type, For Single Phase 2 Wire System Having In Built Astronomical Adjustable Programmable Timer With Minimum 5 Years Battery Backup, 2 Pole Contactor Upto 60 A, With Maintenance Mode To Switch On Street Lights During Time Of Repairs With Energy Consumption Data Recording For Analysis And Lcd Display For Energy Monitoring With Numeric Key Pad In Provided Box Complete. , Quattz Electronic Time Switch , Supplying & Erecting Crimping Type Aluminium Lugs For Cable Upto 16 Sq Mm Complete , Supplying & Erectingms Pole Bracket For Guarding / Lt Oh Line, Fabricated From Angle Iron 50X50x6 Mm And 550 Mm Long For Necessary Nos. Of Provided Insulators And Erecting On Pole With 50X6mm Clampcomplete As Per Specification No. Oh -Pl / Bkt , Providing Pair Of Duly Tested Rubber Hand Gloves As Per Is:4770 Suitable For Working Upto 22Kv Supply. , Supplying And Erecting Insulated D.P. Switch Surface Type / Flush Type 32A 240Vwith Indicator Lamp & Fuse , Supplyingh.C. Pattern Porcelain Fuse Bridge Swith Base & Hc Type Fuse Links240v 32A , Supplying, Erecting & Terminating Xlpe Armoured Cable 3½ Core70sq. Mm. Aluminium Conductor , Supplying, Erecting & Terminating Xlpe Armoured Cable 3½ Core95sq. Mm. Aluminium Conductor , Supplying, Erecting & Terminating Xlpe Armoured Cable 3½ Core120sq. Mm. Aluminium Conductor Withcontinuous , Supplying, Erecting & Terminating Xlpe Armoured Cable 3½ Core150sq. Mm. Aluminium Conductor Withcontinuous , Supplying, Erecting & Terminating Xlpe Armoured Cable 3½ Core240 Sq. Mm. Aluminium Conductor Withcontinuous , Supplying, Erecting & Terminating Xlpe Armoured Cable 3½ Core300 Sq. Mm. Aluminium Conductor Withcontinuous , Supplying, Erecting & Terminating Xlpe Armoured Cable 3½ Core400sq. Mm. Aluminium Conductor Withcontinuous , Supplying & Erecting Crimping Type Coper Lugs For Cable Upto 1.5 To 6Sq Mm Complete… , Supplying And Erecting Two Pole Power Contactor 250V 32A For Time Switch Complete Erected On Wooden Block / Provided Box, With Necessary Materials. , Supplying & Erecting Mains With2x1.5 Sq.Mm F.R Copperpvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole , Supplying & Erecting Mains With 2X4 Sq.Mm F.R Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places. As Per Specification No:Gma / Bw , Supplying And Erecting Mains With Isi Mark Wp2 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg 1-4-3 , Water Proof Tape , Cable Joint Kit Upto 25 Sq. Mm Cable , Cable Joint Kit Upto 35Sq. Mm To 95 Sq Mm Cable , Cable Joint Kit Upto 120Sq. Mm To 185 Sq Mm Cable , Street Light Pole Box Frp , Cement Street Light Pole Clamp With Nut Bolt , M.S. Street Light Pole Clamp With Nut Bolt , Servicing And Primary Maintenance Of Street Light Pole 1 Visit Per Month Pole Included And Also Call Basis. Checking All Wire Connections, Nut Bolt Tighting, Lugs Connection. Old Light Changing & Service Wire Conection Labour Works Etc. , Servicing And Primary Maintenance For Street Light Pole. , Supply &Fixing Of Shakle Hardware With Nut Bolt , Supply And Installation Of Mini Feeder Pillar With Stand , Rcc Road Cheasling Charges With Tractor Breaker ( 1 Hours ) , Tree Triming For Overhead Line , Supplying & Erecting Street Light Control Panel Outdoor Type, For Three Phase 4 Wire System Having In Built Astronomical Adjustable Programmable Timer With Minimum 5 Years Battery Backup, 4 Pole Contactor Upto 60 A, With Maintenance Mode To Switch On Street Lights During Time Of Repairs With Energy Consumption Data Recording For Analysis And Lcd Display For Energy Monitoring With Numeric Key Pad In Provided Box Complete , Supplying, Installing, Testing And Commissioning Of Solar Panel Comprising High Efficiency Poly- Crystalline / Multi Crystalline Photovoltaic Cell 100Wp, 12V With Necessary Clamps And Module Frame On Existing Structure Complete. Specification No. Esd-Sol / Cell , Supplying And Erecting Approved Makebattery With Capacity Of 12 V 40 Ah With Duty Cycle 10-12 Hrs Suitable To Charge On Pv Cell With Necessary Wiring Connections Erected In Powder Coated Protection Box With Stand And Nut Bolts As Per Specification No.Esd-Sol / Bat 4-3-17 , Servicing And Primary Maintenance Of Solar Light Pole 1 Visit In Month Included And Also Call Basis. Checking All Wire Connections, Nut Bolt Tighting, Lugs Connection, Timer Working Condition And Panel Cleaning , Supplying, Installing, Testing And Commissioning Solar Street Light Pole Comprising Of 9 W Led Fitting, 12V 18Ah Maintenancefree Lithium Battery, Min. 40 Wp Spv Module, Ms Powder Coated Battery Box Weather Proof, Mounted On 75 / 80 Mm Dia. B-Grade Gi Pole Of 6 M. Height Along With Brackets, Foundation, Earthling And Necessary Accessories Complete. Specification No. Esd-Sol-Stl ( With 5 Years Warrantee ) , 4-3-13 Supplying, Installing, Testing And Commissioning Solar Street Light Pole Comprising Of 12W X 2 Nos. Led Fittings, 12V Min. 100Ah Maintenance Free Lithium Battery, Min. 120Wp Spv Module, Ms Powder Coated Battery Box Weather Proof, Mounted On 75 / 80 Mm Dia. B-Grade Gi Pole Of 6 M. Height Along With Brackets, Foundation, Earthling And Necessary Accessories Complete. Specification No. Esdsol-Stl , Supplying, Installing, Testing And Comm Issioning Solar Led Mini Hi – Mast 20 W X 5 Nos. Led Luminaries, 2 Nos. X 150 Ah 12 V Lithium Battery, Min. 400 Wp Spv Modules, Mounted On Gi Octagonal Pole With Bottom Of 130 Mm A / F, Top 70 Mm A / F 6 Mtr Height Along With Brackets, Foundation, Earthling And Necessary Accessories, Waterproof Battery Box, Suitable Solar Inverter, Timer Setting Arrangement, Gi / Powder Coated Module Structure, With First 6 Hr. Full Intensity Light Output And Following 6 Hr. With Half Intensity Light Output Along With Solar And Local Electrical Power Supply Charging Facility Complete. ( With 5 Years Warrantee ) , Supplying, Installing, Testing And Commissioning Solar Street Light Pole Comprising Of 7W X 2 Nos. Led Fittings, 12V 36 Ah Maintenance Free Lithium Battery, Min. 100 Wp Spv Module, Ms Powder Coated Weather Proof And Anti-Theft Battery Box. Pole Height 5 M. 16 Lux At 4 M. Complete. Specification No. Esd-Sol-Stl ( With 5 Years Warrantee ) , Providing Rental Basis Hydraulic Bucket Vehicle Of Highth 13 Mtr. And Weight Capacity 200 Kg With Driver, Oprator And Disel Etc. For Per Day Basis.. , Providing & Erecting 8 M High ( Clear Height ) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 135 Mm A / F, Top 70 Mm A / F On Provided Foundation As Per Specificationbajaj Make Make No. Oh- Pl / Opl , Providing & Erecting 11 M High ( Clear Height ) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 210 Mm A / F, Top 90 Mm A / F On Provided Foundation As Per Specificationbajaj Make Make No. Oh-Pl / Opl , Supplying And Erecting Outdoor Stand Mounted Feeder Pillarfor Highmast Of The Same Manufacturer With 63A Tpn Mcb Incomer, Single Dial Timer Switch, 45A Tp Contactor Forautomatic Switching Of Luminaries, 2 Nos 9A Contactors And Raise / Lower Push Button, And Provision For Termination Of Adequate Size Of Incoming And Outgoing Cables Erected In Min. 14 Swg Crca Sheet Box Powder Coated With Supporting Angles, Self-Lock, Gasket And Slanting Top Erected With Cc Foundation Complete , Supplying And Erecting 12.5 M ( Clear Height ) High Mast ( Top 150Mm, Bottom- 360Mm ) With Lowering And Raising Motorized Unit, Lantern Carriage Assembly Suitable For Max. 6 Nos. Luminaries And Its Control Gear Box, Lightning Finial Arrangement For Fixing Aviation Light And Foundation Bolts On Provided Foundation As Per Specificationbajaj Make Make No. Oh-Pl / Hm ( Excluding Luminaries ) . , Upplying And Erecting 16 M ( Clear Height ) High Mast ( Top 150 Mm, Bottom- 410Mm ) With Lowering And Raising Motorized Unit, Lantern Carriage Assembly Suitable For Max. 12 Nos. Luminaries And Its Control Gear Box, Lightning Finial Arrangement For Fixing Aviation Light And Foundation Bolts On Provided Foundation As Per Specification Bajaj Make Makeno. Oh-Pl / Hm ( Excluding Luminaries ) . , Making Cement Concrete Foundation Including Excavation ( 60 X 60 ) Cm X Deep 1 / 6 Of Pole Length In 1:3:6 Cement Concrete 20 X 25 Mm Stone Metal, 45 Cm X 45 Cm X 45 Cm / 45 Cm Dia. X 45 Cm. Height Plinth Duly Plastered, With Necessary Curing And Finishing Complete. ( For Above 9 M Poles ) , Supplying And Erecting Mini Feeder Pillar Triple Pole With 200A Fpmccb As Incomer And 2 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A Consists Of Aluminium Bus Bar 500 V 200 A Complete Erected In 14 Gauge Crca Sheet Box With Supporting Angles, Self-Locks, Gasket And Slanting Topto Be Erected On Provided Foundation As Per Specification No. Sw-Swr / Mfp , Supplying And Erecting Mini Feeder Pillar Triple Pole With 300A Fpmccb As Incomer And 3 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A Consists Of Aluminium Bus Bar 500V 300A Complete Erected In 14 Gauge Crca Sheet Box With Supporting Angles, Self-Locks, Gasket And Slanting Topto Be Erected On Provided Foundation As Per Specification No. Sw-Swr / Mfp , Supplying & Erecting Street Light Control Panel In Powder Coated Crca 14 / 16 Swg Sheet, Outdoor Type, Single Phase, 240 V Consisted Of Suitable Rating Contactor, 24 Hrs Digital / Astronomical Time Switch With Minimum 5 Years Battery Backup, Spn Mcb 63 A Auto / Manual Selector Switch, On / Off Push Buttons, Indicator Lamps, Control Wiring, Metering Device, Etc For Automatic Operation & Overcurrent, Short Circuit, Earth Fault Protection Of Street Lights Upto The Max Load Of 12 Kw On Provided Iron Frame / Cc Foundation Complete. , Providing Earthing With Galvanized Iron Earth Plate Size 60 X 60 X 0.6 Cm Complete With All Materials, Testing & Recording The Results As Per Specification No. Ea-Ep , Providing Pipe Type Earthing With 40Mm. Dia. G.L. Pipe Or 20 Mm Dia. G.L. Rod Complete With All Materials As Per Specification No. Ea-Ep , Supplying And Erecting Regular / Standard Model Ceiling Fan Of 600Mm. Sweep Complete Erected In Position As Per Specification No. Fg-Fn / Cf , Supplying And Erecting Regular / Standard Model Ceiling Fan Of 900 / 1050 Mm. Sweep Complete Erected In Position As Per Specification No. Fg-Fn / Cf , Supplying & Fixing Anchor Type Fastener Fan Hook, With 2 Nos. Of 10 Mm Dia X 75 Mm Long With Necessary Materials For Ceiling Fan. , Providing And Erecting Heat Shrinkable Outdoortermination Kit For 11 Kv ( Ue ) / 22 Kv ( E ) Xlpe Ht Cable 3X Up To 95 Sq. Mm. With Necessary Material As Per Specification No. Cb Jt / Ht , Providing And Erecting Heat Shrinkable Outdoor Termination Kit For 11 Kv ( Ue ) / 22 Kv ( E ) Xlpe Ht Cable 3X240 To 400 Sq. Mm. With Necessary Material As Per Specification No. Cb Jt / Ht , Supplying , Erecting & Terminating 3 X 95 Sq. Mm. Aluminium 22 Kv ( E ) , Xlpe Armoured Cable On Wall / Ceiling Or Laid In Provided Trench / Pipe In An Approved Manner As Per Specification No.Cb-Ht , Supplying , Erecting & Terminating 3 X 300 Sq. Mm. Aluminium 22 Kv ( E ) , Xlpe Armoured Cable On Wall / Ceiling Or Laid In Provided Trench / Pipe In An Approved Manner As Per Specification No. Cb-H , Gst 12 % Charges
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Maharashtra View Result →
20.
Public Administrative Department #10486209 Price Bid
Supply For Chlorine In Aduthurai Town Panchayat , 1. Preparation Tank & Storage Tank : Type: 500 Litres;Cylindrical Vertical Flat Bottom; Size : (Id X Height X Thk)Mm Std;Lifting Hook Suitable Lifting Device Shall Be Provided On Skid; Usable Capacity : Preparatiion & Storage 525 Ltr;Liquid / Solution To Be Handled : Chlorine Designpressureatm+Full Of Liquid; Quantity : 01 Nos.2. Dosing Pump/Transfer Pump : Model : Mmdp-1;Type : Mechanical Diaphragm Type Offered Capacity 0-75 Lph, Spm/Ratio 100/15:1 ; Aphragm Ptfe Flow Control Manually; Turn Down Ration 10:1; Efficiency/Accuracy 97%/+_3% Suction Flanged Type Discharge Pressure 4.0 Kg/Cm2; Prv Set Pressure 5.0 Kg/Cm2; Connection Suction 15 Nb; Connection Discharge 15 Nb; Material Of Wetted Parts Pp ; Qty. 02 Nos [1W +1S].3. Pump Drive Motor : Type : Squirrel Cage Induction Motor Iec Xone-Ie2; Supply System :Ph, Induction, Ac, 415V= 10%, 50Hz+_5%; Mounting/Deg Protection : B 3 (Foot Mounted) / Ip 55; No Of Poles / Rpm: 4 Poles/ 1440 Rpm; Insulation Class / Temp Rise: Class F / Limited To Class B; Method Of Cooling : Tefc; Applicable Standards : Is 325; Rating : 0.5 Hp; Motor Frame Type : As Per Din / Iec 34-7; Duty Class : Si : 100% Continuouns Operation Noise Level (Less Than) : 85;Db (A) At A Distance Of 1 Mtr. 4.Motor – Pump Shaft Coupling :Type : Love Joy/Suitable Flexible Coupling; Qty : 01 Nos.5.Fitting : As Per Ansi 16.11 B;Type : 15 Nb (Sw) , 6. Flanges : As Per Ansi 16.5 B;Size : 15 Nb Swrf # 150; Material Of Construction : Pp/Upvc; Inlet Terminal Flanges / Tank;Flanges 15 Nb Swrf # 150;Outlet Terminal Flanges / Companion Flanges 15 Nb Swrf # 150;Qty At Actual.7. Pulsation Dampner : Type : Volumebottle Type; Capacity 1.5 Lit; Moc Pp/Upvc; Qty 01 Nos. 8. Pressure Gauge With Isolation Valve :Type Bourdon Sensing Type Mounting Direct Bottom;Dial Size 100 Mm; Mocss ; Accuracy 1.6%; Range 0-14 Kg/Cm2; Qty 01 No. 9. Nrv : Type Lift Check Type;End Connection 15 Nb Sw Moc Pp/Upvc;Qty 01 Nos.10. Prv : Type Spring Loaded Connection 15 Nb 300 #; Prv Set Pressure 5.0 Kg/Cm2;Moc Pp/Upvc; Qty 01 Nos.11.Strainer :Flitration Rating 40 Mesh; Size 15 Nb Moc Pp/Upvc; Qty 01 No; 12.Level Guage : Type Transparent Tubular Type; Moc Pp; End Connection 15 Nb 150 # Flanged; Qty 1 Nos. 13.Ball Valve : Type : Ball Valve For Suction & Discharge Material Of Construction : Pp/Upvc; End Connection : Sw; Size 15 Nb Sw # 150; Qty At Actual.14. Piping Within The Skid : Size / Rating Of Pipe : 15 Nb Seamless Sch40/80 Suction Moc : Pp/Upvc;Discharge Moc : Pp/Upvc. 15.Gaskets : Material Of Construction : Spiral Wound Gasket Cs Outer Inner Ss ; Qty At Actual. 16.Fastners : Make Standard Material Of Construction : Ms Galvanised; Qty At Actual. , 17.Skid / Base Frame : Base Frame A Common Base Frame For Tank, Pump And Lifting Lugs, Supports Shall Be Provided; To And Above Scope Of Supply; Stool For Pump Pump Shall Rest Not Less Then 300 Mm; Foundation Bolt M-12 X 150 Mm; Material Of Construction : Cs (Is:2062); Primer / Zomc Rich Epoxy Finish / High Built Epoxy Frame Shall Be Painted With 2 Coats Of Epoxy Primer And 2 Coats Of Epoxy Paint; Colour – Blue Std. 18.Agitator With Control Panel Set 0.5 Hp – 01 No
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
21.
Health and Family Welfare #10433257 Price Bid
Supply Of Machine, Equipment And Others , List Of Machine And Equipments , Laproscopic Hd Camera Brand - Karl Storz/Conmed/Olympus Technical Specification Resolution: 1920X1200 Pixes / 1900X1000 Pixes Cable Length: 300 Cm , Ultrasonic Harmonic Scalpel Brand - Johnson Technical Specification Dimensions: (Hxwxd) 5.3 14.5X15.2 Voltage: 100-240 Vac Frequency: 50/60 Hz Rated Current: 3 Amp , Ultrasonic Harmonic Scalpel Brand - Valley Lab Technical Specification Macrobipolar/Bipolar: 473 Khz Sinusoid, 100% Duty Cycle. Seal: 473 Khz Sinusoid Pulsed , Hand Instruments For Laproscopy Brand- Karl Storz/ Olympus Technical Specification I) Veress Needle: It Should Be With Spring Action Blunt Style -12 Cm: 1 No 10 Cm: 1 No 8 Cm: 1 No Ii) Trocar And Cannula:10 Mm: 2 Nos 7 Mm: 1 No. 5 Mm 6 Nos It Should Consists Of Trocar, Cannula With Insufflation And Multifunctional Valve And Must Have Pyramidal Tip. Iii) Reducer/Reduction Sleeve 5 Mm. 1 No Iv) Telescopes: 10 Mm- 0°- 1 Nos -30? - 1 Nos5 Mm-30? 1 Nos Rigid Rod Lens System Provides Good Resolution And The Better Dept Perception. It Should Have Uniform Image Brightness And Autoclavable. The 300 Forward Oblique Angle And Permits For Greater Latitude For Viewing Underlying Areas Under Difficult Anatomical Conditions. V) Suction Cannula: 10 Mm - 1 No 5 Mm -1 Nos Vi) Laparoscopic Scissors: Curved (Monopolar Metzenbaum Dissector 5Mm Diameter): 1 Nos Straight (Bipolar):1 Nosperitoneal Scissor: 1 Nosvii) Unipolar Forceps (Hook & Spatula): 2 Nos Viii) Bipolar Forceps : 2 Nos Ix) Atraumatic Forceps: Maryland Dissector Forceps: : 2 Nos. Fenestrated Forceps: : 2 Nos. X) Needle Holder (Flat Jaw) With Handle : 2Nos Xi) Monopolar Cable (Reusable):1 Nos. Xii) Bipolar Cable (Reusable): 1 Nos Xiii) Allis (Double Row Of Teeth) Grasper: 1 Nosxiv) Aspiration Needle: 1 Nos. Xv) Reducer/ Reduction Sleeve (5Mm): 1 Nos Xvi) Grasping Forceps (Toothed & Rachet 5Mm): 2 Nos Xvii) Laparoscopic Knot Pusher: 1 Nos Xviii) Clip Applicator (Reusable): 5Mm -: 1 Nos : 10 Mm: Ino Xix) Uterine Manipulator: 1 Nos Xx) Clips( Medium & Large) Xxi) Drilling Needle:1 Nos Xxii) Infiltration Needle: 1 Nos Xxiii) Biopsy Forceps (Toothed Punch Biopsy): 1 Nos Xxiv) Myoma Fixation Screw: 2 Nos Xxv) Tissue Morcellator With Base Unit & Accessories: 1 Nos , Dual Wavelenght Laser Brand- Zeiss Technical Specification Laser Type: Diode, Semiconductor Wavelength : 1470Nm+635Nm Max Power: 15 Watts/1470Nm+5Mv/635 Aiming Beam : 635Nm/1, 4Mw Max Or 515Nm/2, 5Mw Max Operation Mode : Continuous Or Modulated Pulsed Time : 0.05Ms-1000Ms Beam Delivery : Sma905 Connector Optic Fiber Compatible : Optic Fibers Having A Core From 200Um To 1000Um, Na=0.22~0.48 Beam Emission Initiation : Footswitch Controller :Microprocessor Display : 10.1 Ips With Touch Panel Medical Approved Cooling :Internal, Air And Thermoelectric Cooling Power Supply Of The Laser: Dc 24V/8.33A From The Separate Ac Power Supply Of Ac Adapter : Single Phase 100-240Va; 50-60Hz, Max 90W Ac Adapterdc 24V/8.33A Medical Approved Laser Dimensions: 27Cm*24,5Cm X 9Cm Laser Weight: 2.75Kg Laser Case Dimensions : 53Cm X 38Cm X 23Cm Weight Of Laser With Cases : 9Kg Environmental Conditions During Work : From +10 To 24°C Degree, Relative Humidity From 30% Up To 60% Cass Of Medical Deviceiib Laser Safety Class 4 Electric Safety Class I Type B Housing Protection Degree Ip20b , Hd Camera Set Brand- Karl Storz/ Olympus Technical Specification (I) Hopkinsa® Forward-Oblique Telescope 30A, Diameter 4 Mm, Length 30 Cm, A Utoclavable, Fiber Optic Light Transmission Incorporated, Color Code Ed :1 Nos (Ii) Telecam C3 : 1 Nos (Iii) Image1 St™ Hx One-Chip Full Hd Camera Head, 50/60 Hz, Fixed Focus, Prog Ressive Scan, Soakable, Gas-And Plasmasterilizable, Focal Length F = 16 Mm, 2 Freely Programmable Camera Head Buttons, For Use With Image1 X-Link Tc301, Tele Pack + And Tp101 : 1 Nos (Iv) Medical Grade Surgical Monitor - Fhd : 1Nos (V) Cold Light Fountain Power Led 175 Scb, With Integrated Karl Storz-Scb, High-Performance Led And One Karl Storz Light Outlet, Power Supply 11-240 Vac, 50/60 Hz Including: 400 A Mains Cord 20090170 Scb Connecti G Cable : 1Nos (Vi) Fiber Optic Light Cable, With Straight Connector, Extremely Heat-Resi Stant, With Safety Lock, Diameter 4. 8 Mm, Length 250 Cm :1 Nos , T U R P Set Brand-Olympus Technical Specification (1) Cystoscope-Urethroscope Sheath, 22 Fr :1 Nos (2) Telescope Bridge, With 1 Lockable Channel, For Use With Cystoscope Sheaths : 1Nos (3) Working Element, E 1 Working Element (Also For Use With Optical Urethrotome) 2 Cutting Loops2 Coagulat Ng Electrodes 2 High Frequency Cords 1 Protection Tube . The Thumb Support Is Movable. In Rest Position Th Electrode Is Inside The Sheath.:1 Nos (4) Resectoscope Sheath, 26 Fr, 1 Nos (5) Schmiedt Visual Obturator, : 1 Nos (6) Cutting Loop Angled, 24/26 Fr., Units Of 6 : 1Nos Ellik Evacuator:1 Nos (7)Urethrotome Sheath, 21 Fr. Urethrotome Sheath And 2 Luer-Lock Cones.:1 Nos (8) Obturator, For Urethrotome Sheath, 21 Fr.1 Nos Sachse Cold Knife, Straight, Not To Be Used With Hf Current This Artic Le Is Only Available In Units Of 6 :1 Nos , Flexible Cystoscope Brand-Olympus Technical Specification Cysto-Urethro-Fiberscope, With Contrapositive Deflection Mechanism, De Flection Of Distal Tip 210°/140, Direction Of View 0°, Angle Of View 10, Working Channel Inner Diameter 7 Fr., Sheath Size 15.5 Fr., Worki G Length 37 ??, Consisting Of: 11272 Cu1 Cystourethro-Fiberscope 2767 A Case 27023 Fe Grasping Forceps 27023 Ze Biopsy Forceps 13242 Xl Lea Age Tester 11025 E Pressure Compensation Cap 27651 B Cleaning Brush 27 14 Y Lueradaptor , Echocardiography Brand-Ge Healthcare/ Philips / Siemens Healthcare/Bpl Technical Specification A) 2D, M-Mode, Colour M-Mode B) Colour Flow Doppler Imaging C) Fully Steerable Pulsed Doppler D) Fully Steerabie Continuous Wave Recall E) Digital Cine Replay Of All Imaging And Doppler Modalities. F) On Screen Cine Storage & Image Recall G) Digital Image Storage And Patient Archive With True Scanner Frame Rates. H) Full Measurement And Analysis Capabilities. Both On Line And Offline Preferable. I) Imaging Frequencies From 1 Mhz To 15 Mhz J) Review Of Stored Ultrasound Images. K) User Adjustable B Colorization Maps, Gain Settings, Colour Doppler Baseline, Angle Correction And Other Important Parameters With Live/Frozen/Archived Images/Loops. , 12 Lead Ecg Machine (Brand - Bpl/Maestros) Technical Specification Electrocardiograph Should Have Capability Of Recording 12-Lead Ecg And Should Have The Following Features: 1. Should Have Simultaneous Acquisition Of 12 Leads 2. Should Have A Display To Preview The Ecg Waveform Before Printing 3. Should Have 7 Inch Or More Display With High Resolution Screen 4. Should Be Compact, Portable And Easy To Operate 5. Should Have Keyboard For Manual Entry Of Patient Data 6. Should Have Provision For Providing Hospital Name On The Printed Record7. Should Work On Li-Ion Battery8. Should Have A Frequency Response Of 0.01-300 Hz 9. Should Have Sampling Frequency Of 15,000 Hz Or More10. The Device Should Weigh Less Than 5.5 Kgs With Battery11. Should Have A Special Arrhythmia Triggered Mode Of Printing12. Should Have Pacemaker Detection Facility 13. Should Be Able To Record On Different Modes Of Sensitivity: 2.5,5,10,20 Mm/Mv & Agc14. Should Have Different Recording Speeds: 5, 10, 12.5, 25 And 50 Mm/Sec15. Should Have Different Filters Available For Smoothing Of Waveform16. Should Have Ac Filter, Emg Filter: 25 Or 35 Or 45 Hz Or Off17. Should Have Anti-Drift Filter18. Should Have Different Print Formats: 3/6/12, 3X4 With Rhythm Leads, 6X2, 12X119. Should Have A Large Storage Of 700 Ecgs Or More20. In Case Of Error In Lead Connections, The Machine Should Display The Change In Color Of Particular Lead.21. Should Be Able Transfer Data Directly In Pdf Format To Usb22. Should Be Able To Printout Records On Thermal Paper As Well Z-Fold23. Should Have Facility Of Printing In Automatic/ Manual/ Rhythm/ R-R Mode Of Printing24. Should Have Facility For Interpretations And Measurements25. Should Provide Detailed Printout Of Patient Data26. Should Have Paper Of Minimum Width Of 210Mm27. Should Have The Capability To Generate Any Number Of Ecg Copies For Distribution28. Should Be Able To Connect To Pc 29. Should Be Able To Operate To A Maximum Of 4 Hours On A Newly Charged Battery30. Should Have Direct External Printer Connectivity31. The Unit Should Be Portable And Should Be Able To Carry With Help Of A Handle.32. The Product Should Be Ce Certified33. The Manufacturer Should Be Iso Certified34. The Device Should Be Provided With Standard Accessories:A) Ecg Cable (Adult)-1 Nob) Gel Bottle- 1 Noc) Chest Electrodes (Set Of 6)- 1 Nod) Limb Electrodes (Set Of 4)- 1 Noe) Z-Fold Paper - 1 Packf) User Manual-1 No , Multipara Patient Monitor(Brand - Drager/Penlon/ Bpl) Technical Specifications For Multipara Monitor 1. Multiparameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,(Massimo),Nibp (Suntech) Temperature.3. Optional Parameter Etco2, Dual Ibp, Agm 4. Should Have12-Inchcolor Lcd Display.5. Should Have Dual Modes Of Operation: Rotary Knob.6. Should Display 7 Waveforms Or More7. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen.8. Ecg: Should Be Able To Monitor Ecg Through 5-Lead Patient Cab Should Have Manual St Analysis Window ,Should Detect 20 Arrhythmias And Generate Alarms. , The Priority Of Arrhythmia Alarms Can Be Configurable, Should Measure Pvc &Pac Should Be Able To Monitor Heart Rate From 10-300 Bpm Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etcshould Have Pacemaker Detection Facility Respiration: Measurement Range Of 0 To 150 Breaths Per Minshould Have Gain Selection: ×0.25, ×1, ×2, ×4 Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S Should Have Apnea Detection Facility Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 10 Spo2: Should Have Massimo Technologyshould Have Measurement Range Of 0~100 % Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph Should Be Able To Select Sat Sec To Avoid False Alarm 11. Nibp: Must Be Of Suntech Medicaltechnology For Clinical-Grade Blood Pressure Measurement Have Auto, Manual, And Stat Modes Of Operation For Nibp. Should Have A Measuring Range Of 0-280 Mmhg Should Have 2 Channels For Temperature Monitoring Should Have Data Storage Capabilities:72 Hours Of Trend Data Storage. , Bp Machine Brand - Pagoda/ Omron/ Platinium/ Dr Trust/Bpl Technical Specification Should Be Able To Measure Blood Pressure And Pulse Rate In Adult As Well As Pediatric Patients. Should Be Based On Oscillometric Measurement Technology, Using Dynamic Linear Deflation Method. Should Have Backlight Lcd Display With Easy To View Readings In Dim Light. Pressuremeasurement Range Should Be 60 To 250Mm Hg Systolic, And 40 To 200Mm Hg Diastolic. Pressure Display Accuracy Of +/- 3 To 5 Mm Hg Pulse Rate Measurement Range Of 40 To 200 Per Minute Pulse Measurement Accuracy Of Within 5% Should Include Ac Adapter (Input Range 100-240V And Output Voltage Dc 6V), Preferably With Rechargeable Battery (3.6V To 4.8V, 1900 To 2400Mah) Cuff (22 To 32 Cm Size) Should Be Supplied With Standard Adult Size Single Button Operation For Start And Stop Functions With Auto-Inflation Of Blood Pressure Cuff. , Ventilator Brand - Drager/Bpl/Medisys Technical Specification 1. The Ventilator Should Be High-Endventilator Suitable For Ventilating To Adult And Pediatric Application. Should Have Advanced Microprocessor Control System With Individual Selection Of Various Ventilation Parameters. 2. The Unit Should Be With Altitude Compensation For Volume And Btps Correction For Monitoring3. The Unit Should Be Of Wall Independent Gas Delivery System. Demonstration Of The Equipment Is A Must Demonstration Of The Equipment Is A Must4. Should Have Facility For Invasive And Non-Invasive Ventilation;5. The Ventilator Should Have 12” Or More Lcd Screen With Touch Facility For Display Of Waveforms. Should Have Brightness Modes Like Day/Night-Mode. The Real Time Display Of All Parameters/Waveforms Should Be Clearly Visible From All Angles6. Should Have Modes Of Ventilation Equipped With Newer Modes Of Ventilation:A) Assist/ Controlb) Volume Control Modes: Vcv, Vc-Simv, Plvc) Pressure Control Modes: Pcv, Pc-Simv, Bi-Level, Bilevel-St, Pc-Aprvd) Spontaneous Ventilation Modes: Psv, Cpap, Bilevel /Similar, Bilevel St / Similare) Prvc/Pcv-Vg/Dynamic Bilevel/Or Its Equivalent Modef) Closed Looplung Protective Mode- Asv/Nava/Wobov/Alpv/Smart Care (At Least 1 Of The Mentioned Mode Is Mandatory)G) Should Have Pav (Proportional Assist Ventilation) / Pps (Proportional Pressure Support)/ Paps (Proportional Adaptive Pressure Support)H) Cpr (Resuscitation Mode),I)Niv In All Pressure Modes7. Hfot /Nasal Cpap Breathing Therapy Should Be Capable Of Adjusting The Range Up To 60Lpm8 A) Apnea Backup Ventilation In All Modes8 B) It Should Have Weaning Analyzer Tools : Sat & Sbt9. Should Have In-Built Nebulizer With Capability To Deliver Fine Particle Size Of To Be Used In Line10. Should Have Facility To Measure And Display The Following Parameters:A) Airway Pressure (Peak & Mean)B) Tidal Volume (Inspired & Expired)C) Minute Volume (Expired)D) Spontaneous Minute Volumee) Total Frequencyf) Fio2 Dynamicg) Intrinsic Peep, V Trap & Time Constant (Rcexp)H) Resistance & Compliance11. Automatic Compliance And Leakage Compensation For Circuit And Et Tube 12. Should Have Facility Of Logbook, For Events And Alarms With Date & Time 13. Should Have Following Setting & Monitored Parametersa) Tidal Volume; Pre-Set Range For Both Pediatric & Adult Modes To Be Providedb) Inspiratory Pressure (Up To 100Cm Of H2o);C) Respiratory Rate 1 To120 Bpm;D) Apnea Back Up Rate;E) Peep: 0-50 Cmh2of) Inspiratory Flow: 0-120 Lpmg) Max Peak Flow : 280 Lpm Or Betterh) O2 Concentration: 21-100%I) Pressure Support: 1-(100-Peep) Cmh20j) Fio2 Setting Range Between 21% And 100%;K) Pressure Flow & Volume Curves;L) Loop For V-Flow, Flow-P, Flow-Paw And At Least 5 Storage Spaces For Reference Loopsm) I: E Ratio: 150:1 To 1: 299N) Ramp Time: Up To 3 Seco) Inspiratory Time: 0.2 To 15Sp) Pause Time; Exp/Insp Holdq) Pressure Trigger: Up To -10Cmh2o And Flow Trigger Up To 20 Lpm;R) I Flow/T Plateaus) Resistance & Compliance (Cdyn & Cstat)T) Leakageu) P Plateau 14. Should Have Weaning Parameters;Rsbi,Vt Spont, R Spont ,Vt/Ibw15. Should Have Weaning Parameters;Rsbi,Vt Spont, R Spont ,Vt/Ibw16. Facility To Calculate Lower And Upper Inflection Point (P/V Flex Points)Should Have Recruitment Manoeuvre17. Should Have Automatic Suction Routine & O2 Flush18. Should Have A Dedicated Bronchoscopy Function To Allow & Compensate Ventilation While Performing Bronchoscopy19. Should Have Trend Of 7 Days And Above With Facility To Transfer Through Usb Interface20. Alarms Should Be User Friendly, Audio And Visual With Text Message, System Alarm Should Be For:A) Pressure Changes (High/Low)B) Tidal Volume Changesc) Minute Volume Changesd) High Peepe) High/Low O2 Concentrationf) Power Failure And Low Batteryg) Patient Disconnectionh) Apnea 21 A) The Ventilator Should Have Facility For Co2 Monitoring. Should Have Inbuild Etco2 Interface & Software To Accommodate External Optional Volumetric Etco2 In Future21 B) Should Be Upgradable To :Metabolic Monitoring (Indirect Calorimetry).Price To Be Quoted As Optional.22. The Ventilator Should Not Weigh More Than 12 Kgs 23. Ventilator Should Have In Built Non- Consumable Paramagnetic Oxygen Sensor That Shouldnot Require Change For At Least 5 Years.24. Flow Sensor Should Be Differential Pressure Technology, Or Ultrasonic.Flow Sensor Must Be At Expiratory End. Should Be Maintenance Free, Reusable And Autoclavable.The Flow Sensor, Inspiratory Port, Expiratory Port Should Be Easily Removable Without Using Any Tools & Should Be Autoclavable.25. Should Have Usb /Serial Interface For Communications With Networked Devices26. The Ventilator Should Have On Screen Help Menu For Alarm, Ventilation Mode & Ventilator Settings. The On Screen Help Menu Should Guide User On Solving The Alarms; Providing Information On Ventilation Modes & Settings. 27. Should Support Dual Limb Circuits Of Any Make And Not Ventilator Model Specific Circuits28. The System Should Have Inbuilt Rechargeable Battery With Backup With Minimum 2 Hours29. Power And Gas Requirements: A) Power Input To Be 220-240Vac, 50Hz (100-240 Vac) B) Gas Input (Air And Oxygen) - 29-100 Psi (29-87 Psi)30. The Ventilator Should Be European Ce Certified Or Us Fda Approved, And The Manufacturing Company Should Be Iso Certified.Accessories/Consumables To Be Supplied With Main Unit I. Icu Ventilator With Trolley – 1Nosii. Reusable Adultcircuit - 1 Nos Iii. Hinged Support Arm – 1 Nosiv. Hme Filters—5Nosv. Bacterial Filters-5Nos Vi. Hepa Filetr-1Nos Vii. Test Lung -1Nos Viii. High Pressure Oxygen Inlet Hose – 1Nos , Projector With Screen Brand - Epson / Benq / Lg Cinebeam Technical Specification Ce Marked, Power Supply: 220-240 V Ac, 50/60 Hz, Transparent Lcd Panel Display System, Minimum 5200 Hours Lamp Life, Min. 5800 Lumens Brightness, Contrast Ration 10000: 1, Aspect Ratio 16: 10, Resolution Xga (1024 X 786) With Hdmi And Vga In, Lan & Usb Support, Wireless Support, Light Weight, Remote Control Etc. , Phaco Emulsifier Machine Brand-Alcon Legion / Zeiss Technical Specification 1. Operating Frequency Should Be Approx. 40 Khz 2. Handpiece: Ultralight Ultrasound 4 Crystal Piezoelectric Hand Piece. 3. Us Modes: Continuous, Pulse, Single Burst, Multi Burst, Continuous Burst, Automated Programmable Modulation (Apm) 4. Automated Ultrasound Power On Demand: Ultrasound Management Technology That Automatically (De)Activates Ultrasound Us Delivered Only When Needed Ept Up To 50% Less & Better Followability. 5. Type Of Infusion: Iop Controlled, Synchronized Fluid Exchange System That Directly Measures And Simultaneously Controls Both Infusion And Aspiration Volumes In Real-Time. It Actively Compensates For Incision Leakage. Quattro Controlled Forced Infusion. 6. Display: 24 Inches Touch Screen. 7. Iop Range: 30-120 Mmhg 8. Vacuum Range 0 To 700 Mmhg 9. Aspiration Flow Rate 0 To 120 Cc/Min 10. Aspiration Control Modes: Vacuum Controlled Mode, Flow Control Mode 11. Chamber Stability: Irrespective Of Type Of Cataract, Surgical Conditions, Leakage (0 -12 Ml/Min) It Keep Chamber Stable & Maintain Targeted Iop Throughout Procedure. 12. Iop Recovery Time After Occlusion Break 200-250Ms For Vacuum In Range Of 200 -600Mmhg. 13. U/S Tips: Coaxial Phaco With Incision Size 2.2 Mm 14. Vitrectomy: Pneumatic Cutting Device15. Type Of Vitrectomy Cutter: 23G Anterior Vitrectomy Cutter16. Anterior Vitrectomy Range:Cut Rate 30 To 5000 Cuts Per Minute. 17. Actuation Medium For Vitrectomy: Compressed Air From Internal Source 18. Diathermy: Bipolar With Fixed And Linear Control Via Foot Pedal. 19. Type Of Diathermy Handpiece: Diathermy Forceps And Diathermy Pencil Eraser. 20. Instrument Tray Arm Length: Should Be 800Mm Or More. 21. Dual Linear Footswitch 22. Should Be Usfda And Ce Approved 23. Online Ups Should Be Providedaccessories: Phaco Hand Piece(Coaxial) -2 Coaxial Handpiece Tip I – 2 I/A Bi Manual Hand Piece – 2Phaco Tip (2.2 Mm)- 10 Phaco Sleeve (Silicone)(2.2Mm) – 10 Test Charnber- 10 Tubing And Cassettes (Disposable) – 100 Diathermy Cable With Forceps – 2 Phaco Wrench-2 Vit Cutter- 23 G; Single Use – 6Sterilization Container/ Tray , Autorefractometer & Keratometer (Ark) Brand-Zeiss- Visuref 150 Technical Specification (A)Device Data.(A) Refraction(1) Sphere -25.00D To +22.00D (In Steps Of 0.12D/0.25D)(Ii) Axix 0 To 180*) (B) Keratometer(A) Corneal Curvature 5.00 To 10.20Mm (In Steps Of 0.01Mm)(B)Corneal Redraction-33.000 ?? 67.50D (In Steps Of 0.12D/0.25D)(C) Corneal Astigment-0.00D To-15.00D50d (In Steps Of 0.12D/0.25D)(D)Axis 0 To 180* (In Seps Of 1*) (E) Corneal Diameter (2.00 To 1200Mm (In Steps Of 0.10Mm) , Humphrey Fied Analyzer ( Hfa3) Brand-Zeiss Technical Specification • High Quality Goldman Standard Automated Full Field Perimetry Of International Standard With Bowl Size Radius = 30Cm. • Computer & Monitor Should Be Integrated In The Perimeter (No External Computer). • Stimulus Size I, Ii, Iii, Iv & V.• Background Illumination 31.5Asb.• Maximum Temporal Range 80Deg.Suitable For Central 30, Neurological Tests As Well As Full Field Testing. • Central Field Test Patterns 30-2, 24-2,10-2, Macula.• Peripheral Field Test Pattern 60-4, Nasal Step, Custom Test. • Threshold Test Strategies Full Threshold, Sita Standard, Sita Fast , Full Threshold, Fast Pack, Sita - Swap.• Screening Field Test P-60, Ff-80, Ff-120, Ff-240,Nasal Step For Periphery .• Screening Test Strategies Two Zone, Three Zone And Quantify Defects.• Glaucoma Hemi Field Test, Heijl –Krakau Blind Spot Monitor• Video Eye Monitoring, Gaze Tracking Monitoring System, .. Vertex Monitoring And Head Tracking. • Touch Screen On Crt Monitor, Keyboard & Provision Of External Monitor & Keyboard.•Internal Hard Disk Drive.• Stimulation Duration 200Ms, Wavelength Broad Band Visible Light• Stimulus/Background Colour White On White.• Swap (Blue On Yellow) Perimetery. • Auto Pupil Measurement. • Kinetic Testing & Custom Kinatic Testing. • Motorised Chinrest, Motorised Table, Laser Jet Printer • Glaucoma Progression Analysis ( Gpa ) Software For Monitoring Disease Progression. With Visit Wise Graph &Visual Field Index (Vfi).• Releye Monitor.• Forum Software For Archiving & Offline Analysis Of Patient Data & Gpa Analysis Etc.• Hfa Dicom Gateway. , Laser Dcr Brand-Medfin Technical Specification Applicationsdacryocystorhinostomy Amplifying Medium Diode Ergonomics Tabletop Wavelength-980Nm Average Power -8W Weight -1.2Kg (2.65Lb) , Automatic Tourniquet System With Hose Cuffs Brand - Zimmer Biomet (Model Ats-5000) Number Of Ports Dual Port Number Of Potential Cuffs Dual Cuff Dual Cuff Mounting Options Table Or Pole Mount Table Or Pole Mount Battery Type And Life Lithium Ion 6 Hrs Lithium Ion 6 Hrs User Interface Touchscreen Touchscreen International Alarm Standard 60601-1-8 Compliant Compliant Display 10.1” Color 7.0 Color Minimum/Maximum Pressure 20/600 Mmhg 50/600 Mmhg Pressure Accuracy ±3 Mmhg (20–600 Mmhg) ±4 Mmhg (50-600 Mmhg) Limb Occlusion Pressure (Lop) Allows For Patient Specific Pressure, Which Allows For The Minimum Pressureto Be Used.Yes Noline Occlusion Detection (Acoustic Reflectometry)A Kinked Pneumatic Tube Can Prevent An Inflated Cuff From Deflating, Resulting In Unintentional Tourniquet Pressure. This Alarm Alerts Or Staff That There Is An Occlusion In The Line To The Cuff.Yes , Battery Opreated Heavy Duty Drill & Saw Brand -Manman/Biotech Specifications--- Drill And Reamer Hand Piece Attachments, Oscillating/S Reciprocating Saw Hand Piece Charger And Sterilization Handpiece For Drilling & Reamingtrigger Type Single Modes Available - Reverse & Forward Modedrill Speed 1000 Rpm Approxdrill Torque 4 Nm (35+ In Lbs)Ream Torque 16.5 Nm (145+ In. Lbs)Weight Of Hp With Batteries 1250 Gms Drilling And Reaming Attachments Hudson/Zimmer/Trinkle Reamer Attachment - Yesao Reamer Attachment - Yesao Type Drill Attachment With Quick Coupling - Yesjacobs Chuck With Minimum 6 Mm - Yeskeyless Chuck -Yes Wire Driver Attachment - Yespin Driver Attachment - Yes Dhs Reamer Attachment With Quick Coupling - Yesoscillating/Sagital Saw Hand Pieceergonomic Pistol Grip Design For Maximum Comfort And Control Yes Weight Of Hp With Batteries.- 1350 Gmssaw Speed - 15000+ Cpmcutting Arc - Between 4 To 5 Degreenoise Level - 60-85 Dblspecial Blades Each For Tkr And Thr (Nos) - 10 Battery Specifications Type Of Battery Lithium Ion (Li-Ion) Number Of Batteries 2 , Electric Cautery Machine Brand - Shalya/Enertech/Eclipse/Valley Lab 1) Unit Should Have Microprocessor-Controlled Tissue Feedback Technology 2) Unit Should Have No Of Bipolar Modes Available 3) Unit Should Have Pure Sinusoidal Output Waveform In Hf Power Output In Cut And Bipolar Modes. 4) Type Of Display Should Be Lcd Touch Screen 5) It Should Adjust Power Level Automatically Depending On Tissue Type. 6) It Should Have Two Monopolar Output Channels. 7) Bipolar Current Meter Bipolar Current Meter 8) Unit Should Deliver Two Coagulation Output At A Time With Independent Control Over Each Output For On & Off. 9) Both Channels Should Work By Foot And Hand Control. 10) It Should Complete Self Testing During Power On. 11) Power Efficiency 98 Or More Than 98 12) Availability Of Advance Cutting Modes For Regular Open Surgery 13) It Should Accept Disposable And As Well As Reusable Patient Plate. 14) Unit Should Have Tissue Feedback, Pulsed Interval-Controlled Pulse Cut Function. 15) It Should Accept Dual Area And Single Area Patient Return Electrode. Should Give Green Indication If Dual Area Patient Plate Applied To Patient & Red Indication With Alarm Tone If The Patient Plate Is Not Applied. 16) Bipolar Should Work Without Patient Plate Or Patient Plate Error Condition. 17)Bipolar Should Have Auto Facility To Start & Stop Working Without Footswitch. 18) Unit Should Have Adjustable Delay Activation In Auto-Bipolar. 19)It Should Have Randomized Spray Coagulation For Larger Area Coverage.20)It Should Be Upgradeable For Argon Delivery Module From The Same Oem.21) Unit Should Be Useful For Underwater Procedures. 22) It Should Have Alarm Facility After Completion Of Bipolar Coagulation. 23) Unit Should Have Time Out Function For Automatic Stop The Hf Output If Prolong Unintended Activation. (Optional)24) Unit Should Have Touch Key Pad For Power And Mode Selection.25) System Should Give Error For Faulty Handswitch Of Footswitch In Monopolar & Bipolar.26) Unit Should Give Error For Faulty Keypad. 27) It Should Have No Of Segments Of Display 3. 28) Unit Should Operate From 180 V To 265 V Without Using External Stabilizer. 29) It Should Have Independent Foot Switch For Monopolar Two Paddle. 30) It Should Have Independent Foot Switch For Bipolar Single Paddle. 31) Unit Should Have Facility To Connect Either Monopolar & Bipolar Footswitch.32) Unit Should Have Remote Power Setting Facility From Sterile Field With Conventional Hand Switching Pencil. 33) It Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification. 34)Manufacturer Iso 9001: 2008 & En Iso 13485:2012 Certified Company.35) Warranty Must Be 3 Years Or Higher 36) It Should Be Supplied With Following Reusable And Autoclavable Accessories: -1. Patient Return Electrode …………………….1 No.2. Hand Switching Pencil………………………. 1 No.3. Foot Switching Pencil…………………………1 No.4. Bipolar Forceps …………………………………1 No.5. Cable For Bipolar Forceps……………………1 No.6. Monopolar Footswitch ………………………1 No.7. Bipolar Footswitch ……………………………1 No. 8. Universal Adaptor …………………………….1 No.Set Of Electrode (Angled, Ball And Needle).1No10. Trolley With Lockable Castor Wheel Should Be Supplied1. Unit Should Be Eu Ce (4 Digit Notified Body Certified)2. All Sockets Should Be Of Blinking Light Type When In Use To Identify The Used Mode 3. Availability Of Test Report From Central Govt/ Nabl/Ilac Accredited Lab Covering All Parameters. And Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification. , Arthroscopy Set (Brand- Smith +Nephew / Karl Storz) Arthroscopy Set 30° (Arthroscopic, Sheath And Obturator) Wide Angle, Direct View 4K High Definition Arthroscope. Light Guide Insertion On Definitione Direction View With A J-Lock Fixation For Cannula.Working Length Of Not More Than 160Mm Optimal Centre-To-Edge Resolution For Enhanced Picture Quality Angle Of View: 30 Degree Diameter: 4Mm Arthroscopies Should Be Supplied With Compatible Cannulas High Flow, Double Valve, Fully Rotatable With Fenestrated Tip & Conical And Blunt Tip Obturator, Sheath- 5.95 To 6.0Mm, High Flow Diagnostic Cannula, Double Valve, Fully Rotatable Cannula With Fenestrated Tip. Trocar-4.5Mm Conical Obturator To Fit With Cannula. Arthroscopy Set 70° (Arthroscopic, Sheath And Obturator) Wide Angle, Direct View 4K High Definition Arthroscopic Light Guide Insertion On Opposite Side Of The Direction Of View With A J-Lock Fixation For Cannula. Fully Rotatable With Fenestrated Tip & Conical And Blunt Tip Obturator. Sheath- 5.95 To 6.0Mm, High Flow Diagnostic Cannula, Double Valve, Fully Rotatable Cannula With Fenestrated Tip. Trocar-4.5Mm Conical Obturator To Fit With Cannula. Arthroscopic Power Shaver System: Input Voltage Of 100 To 240V, 50/60 Hz Power Consumption Not More Than 350Va. Two Separate Receptacles For Motor Drive And Powered Instrumentation. Shaver Should Have 2 Modes Of Oscillation For Aggressive Cutting Shaver Should Have Button For Flush Lavage Of Joints On Footswitch. Autoclavable Ultra-Light Hand Piece With Suction Facility, With 3 Hand Control Buttons And Replaceable Cable Long 10Ft (3 M). Maximum Torque Should Not Be Less Than 32Oz.In And Weight Should Not Be More Than 212 Gms Pedal Style Footswitch With 3 Operating Modes I.E. Forward, Reverse And Oscillation. On-Line Lcd Display For Speed And Direction Referral. Should Communicate With The Fluid Management System Once Connected With The Cable. Camera Control Unit: System Must Have Inbuilt 4K Uhd Camera Console, Led Light Source & Wifi Enabled Image Management System With Recording Via Usb Port Along With Recording In App Through In Built Wifi. Camera Resolution Must Be 3840*2160 (Native) 4K Camera Head: Camera Head Should Have 4K, 3 Chip Mos Video Sensor Technologymust Have Transport Shock And Vibration Compliance With Ista 3Avideo Field Rate 60 Hz Must Have C-Mount Autoclavable Coupler With 19.5 Mm Coupler Length Opt For 4Mm Scopes Must Have Digital Zoom Video Data Transmission High-Speed, Low-Voltage Differential Serial (Lvds), Digital Transmission Via 12-Foot Camera Cablevideo Output Format Full Uhd 2160P, 100% Compatible With Smpte St-425-5 When Used With The Ccu Altitude: 3000 Meters Maximum 4K Monitor: Monitor Should Have Resolution 4096 * 2160 Pixels Monitor Should Support Picture Size (Diagonal) 789.06 Mm (31 1/8 Inches) 1387.8 Mm (54 3/4 Inches) Monitor Should Support Effective Picture Size 698 * 368.1 Mm (27 1/2 * 14 1/2 Inches)Monitor Should Support Pixel Pitch 0.1704 X 0.1704 Mm Monitor Should Have Aspect Ratio Of 17:09Monitor Should Have Pixel Efficiency Of 0.9999 Size Is -125Mb 1300 Seconds Video / Gigabyte Storage 10000 Images/Gigabyte Storage Airprintt Is Required. , Fess Instruments Set Nus Surgery Fess & Dcr Surgery Instruments Brand -Kalelkar / Besco Blakesley Forceps 0 Blakesley Forceps 45Blakesley Forceps 90° Thrucut Forceps 0Thrucut Forceps 45° Thrucut Forceps 90 Maxillary Sinus Forceps 30, 90, 120Hewiser Forceps Tubular Rotatable Kerrison Punch Straight Kerrison Punch Curved Backbiting Forcep Tubular Rotatable Stammberger Ostrum Punch (Mushroom Forceps)Giraffe Forceps Upturned 55, 70, 90, 110 With Vertical Or Horizontal Opening Fronntal Sinus Bougie Set Of 4Sickle Knife Sharp/Blunt Ball Probe Double Ended Right Angledball Probe With J Hook Double Endedantrum Curette Oval Or Round Cup Suction Canulla 45 Or 90° , Micro Ear Surgery Instrument Set (Ear Surgery Instruments) (Stapedectomy Instruments) Brand -Kalelkar / Besco Technical Specification Sickle Knife , Circular Knife Flag Knife , Sickle And Flag Knife Double Ended , Sickle And Circular Knife Double Ended Circular And Flag Knife Double Ended , House Curette Double Ended, Elevator Pick Straight/Curved/Right Angled , Fisch Perforator 0.3 Mm To 0.8 Mm. Hand Burr , Piston Depth Guage , Stapedectomy Instruments , Piston Cutting Jig Piston Autoclaving Box , Teflon Pistonspistion Crimper Micro Ear Scissor Belluchi Operative Ear Speculam Set Of 4 Black Slotted Or Plain Endural Retractor 2X2endural Retractor Left/Right Plester Micro Suction Canulla 116 To 24Gmicro Suction Canulla Adaptor Silicone Suction Tubecartilage Slicer , Tonsillectomy Instruments Set Brand -Kalelkar / Besco Technical Specification Davis Boyles Mouthgag With 5 Blades Davis Boyles Mouthgag With 5 Slotteddraffin Bipod Stand With Plate Tonsil Holding Forceps Tonsil Dissector Cum Pillar Retractortonsil Dissection Forceps Tonsil Artery Forceps Straighttonsil Artery Forceps Curvedtonsil Artery Forecps Negustonsil Scissor Tonsil Snare Tonsil Snare Wire +Quincy Foreps +Adenoid Curette With Cage + Adenoid Currette Without Cage + Younker Suction Canulla +B.P.Handle No 7 + Negus Knot Tier +Thrroat Instruments Tracheatomy Surgery Instruments + Tracheatomy Tube Chevalier Jackson/Fuller + Mosquito Artery Forceps + B.P.Handle No 3 + B.P. Blade No 11 + Fine Scissor 4 +Tracheal Dilating Forceps + Kilner Catpaw Retractor +Skin Hook + Single Hook Retractor +Double Hook Retractor , Nasal Surgery Instruments Set (Septoplasty Instruments) Brand -Kalelkar / Besco Technical Specificationkillians Nasal Speculam 2 To 3.5 + St. Clair Thomson Nasal Specularm Set Of 4 B.P. Handle No 3+Freersdouble Ended Mucopericondrial Elevator + Symes Double Ended Mucopericondrial Elevator + Howarth Double Ended Mucopericondrial Elevator Symes Double +Suction Elevator + Lucs Forceps Round Or Heart Shape + Jensen Middleton Septum Cutting Forceps + Jensen Middleton Septum Punch Forceps + Turbinectomy Scissor + Ballenger Swivel Knife Bayonet Shape + Tilleys Nasal Gouge Bayonet Shape With V Cut Or. Plain + Hammer (Mallet) + Submucosal Diathermy+ Needle/Ball Probe + Nasal Packing Forceps + Spring Scissor + Catspaw Retractor + Tongue Depressor + Rhinoplasty Surgery Instruments + Raps + Cricoid Hook + Jenkins Chisel + Alar Retractor + Aufritch Nasal Retractor + Ash Septum Forceps + Walsham Septum Forceps + Gillies Osteotome + Nasal Packing Forceps + Silver Nasal Chisel With Guard Left/Right + Skin Hook + Cottle Retractor + S.M.R Instruments + Killians Nasal Speculam 2 To 3.5 + St. Clair Thomson Nasal Speculam Set Of 4 + Freers Double Ended Mucopericondrial Elevator + Symes Double Ended Mucopericondrial Elevator + Howarth Double Ended Mucopericondrial Elevator + Suction Elevator + Turbinectomy Scissor + Ballenger Swivel Knife Bayonet Shape + Tilleys Nasal Gouge Bayonet Shape With V Cut Or Plain + Hammer (Mallet) , Micro Laryngeal Surgery Instruments Set Brand -Kalelkar / Besco Laryngoscope Mls Black Finish Adult/Child/Paediatric With Fiber Optic Carrier Chest Supportlaryngoscope Distending Operating Type Laryngoscope For Filling With Endoscopemls Forceps Cup Type Straight/Left/Right/Upward/Downward Mls Forceps Serrated Type Straight/Left/Right/Upward/Downwardmls Scissor Straight/Left/Right/Upward/Downward Mls Vocal Cord Spreader Mls Mini Larygeal Forceps Triangular End Mld Needle Holdermls Ssickle Knife Mls Circular Knifemls Flag Knifemls Probe 45°, 90°Mls Curettemls Handle For Use With Straight Instumentssuction Tube With Thumb Control Insulated Probe For Coagulationbronchoscope/Esophagoscope & Instrumentsbronchoscope Negue Type Any Size With Fiber Optic Carrier Esophagoscope Any Size With Fiber Carrierhypopharyngoscope (Esophageal Speculam) With Fiber Optic Carrier Forceps Alligator Grasping Single Actionforceps Peanut Soft Tissue Single Actionforceps Cub Biopsy Type Single Action Forceps Patterson Type Single Actionforceps Universal Biopsy & Grasping Single Actionforceps Alligator Grasping Double Actionforceps Peanut Soft Tissue Double Actionforceps Cup Biopsy Type Double Actionforceps Patterson Type Double Actionforceps Universal Biopsy &Ngrasping Double Action Suction Tube Rigid With Thumb Conntrol , Mastoid Surgery Instruments Set Brand -Kalelkar / Besco B.P. Handle No 4 Kilner Catspaw Retractormollison Mastoid Retractor 3X3 Mollison Mastoid Retractor 4X4mahadevaiah Modified Mastoid Retractor Left/Right Jensen Retractorjolls Retractor Periosteal Elevatoroperative Ear Speculam Set Of 4 Black Slotted Or Plain Micro Suction Canulla 11G To 24Gmicro Suction Canulla Adaptor Mastoid Suctioncanulla Set Of 4 With Thumb Grip Sickle Knifecircular Knifeflag Knife House Curette Double Ended Elevator Adsons Toothed Forceps Adsons Non Toothed Forceps Needle Holder 6 Fine Scissor 4Micro Ear Crocodile Serrated Forceps Micro Ear Crocodile Cup Forceps Micro Ear Crocodile Scissors Malleus Nipper Ball Probe 45 Degree/90 Deegre Vien Graft Pressossicle Holding Forceps , Fiberoptic Flexible Video Laryngoscopy System Brand -(Penlon / Karl Storz) Specification 1) It Should Be Very Portable And Light Weight Device With Minimum Display Size Should Be 4 Inch With High Resolution Anti Reflective Display. 2) Should Have 180 Degree Horizontal Screen Rotation With Vertical Movement For Betterclinical Assistance. 3) It Should Be A Lithium Ion Rechargeable Battery-Operated Device With Low Battery Indicator. 4) Minimum Operation Item Should Be 130 Mins. 5) It Should Have Led Light Source At The Tip Of The Blade With Minimum 2 Megapixel Cmos Camera For Better View. 6) It Should Have Channelled And Without Channelled Blade Option. 7) Should Have 4Gb Inbuilt Memory For Continuous Recording & Image Capturing. 8) Blades Sizes Should Be Size 1,2, 3, 4,5 . 9) Blade Should Be Affordable, Sterile Which Connect Laryngoscope Handle With Lock. 10) Battery Life Cycle Should Be Minimum 300 Times. 11) It Should Have Iso & Conformity To Ce. , Fiber-Optic Video Bronchoscope(Brand - Karl Storz /Olympus ) Specification Fiber-Optic Video Bronchoscope Required With Video Illumination To Visualize And Document The Operational Area On Screen. It Should Consist Of Following Features: Monitorscreen 8 To 12 Inch In Size For Display With Touch Screen To Control Features With Hdmi Output For Connecting To A Big Screen Which Can Display Picture Simultaneously On Both Screens.Monitor Should Have Two Ports To Connect Two Video Endoscopes At One Time And Pictures Can Be Swapped Using Touch Screen. Monitor Should Be Chargeable, To Be Supplied With Charger And Should Have Facility To Be Used While Charging. Monitor Resolution Should Be Minimum 1920 X 1200 Pixels In 16:9 Format.Integrated Recording Of Video & Still Images Should Be Possible On Data Card Or Usb Drive With Jpeg And Mpeg Format Which Can Be Easily Transferred To The Computer/Laptop. Documented Videos & Still Images Should Be Easily Recalled On The Monitor. Monitor Should Have A Facility To Connect Flexible Scope Directly Without Any Special Coupler Or Accessory. Monitor Should Have Picture-In-Picture & Side-By-Side Mode To View Images From Flexible Video Scopes. Monitor Should Be Splash Proof According To Ip 54 And Should Be Shock Resistant.Monitor Should Have Lithium-Ion Rechargeable Batteries And Run For At Least 100 Mins. When Fully Charged. Soft Bag From Same Manufacturer Should Be Supplied To Place The Monitor And System Can Also Be Operated Without Taking Monitor Out From The Bag. Same Monitor Should Be Compatible With All The Below Mentioned Scopes Of Same Manufacturing Principal Company .Reusable Fiber Optic Video Bronchoscope.Single Use Flexible Intubation Video Endoscope A Fiber Optic Bronchoscope Is A Medical Device Used To Visualize The Airways During Bronchoscopy, A Procedure Where A Thin, Lighted Tube Is Inserted Into The Lungs To Examine Them. The Specifications Of A Fiber Optic Bronchoscope Typically Include Its Outer Diameter, Working Length, Field Of View, Angulation Capabilities, And The Diameter Of Its Working Channel. Key Specifications:Diameter: Bronchoscopes Come In Various Sizes, With Outer Diameters Ranging From 2.5 To 10 Mm. Smaller Diameters (E.G., 4.9 Mm) Are Suitable For Smaller Patients, While Larger Diameters May Offer Better Image Quality And Suction Capabilities. King Length: The Working Length, Which Is The Distance From The Distal End Of The Bronchoscope To The Insertion Point, Typically Ranges From 30 Cm To 60 Cm. View: This Refers To The Angle Of Vision That The Bronchoscope Offers. A Wider Field Of View (E.G., 110-120 Degrees) Allows For A Broader View Of The Airways. Angulation: The Ability To Bend The Tip Of The Bronchoscope Allows For Maneuvering Into Various Airways. Up And Down Angulation Capabilities Are Typically Around 180 Degrees And 130 Degrees Respectively King Channel Diameter: The Working Channel Is The Passage Through Which Instruments Like Forceps For Biopsies Or Suction Devices Can Be Passed. It Is Typically 1.2-2.3 Mm In Diameter Other Notable Specifications: 26/25 All Above Equipment Should Be From Same Manufacturers And Usfda & Ce Approved , Anaesthesia Workstation Complete With Anaesthesia Gas Delivery System, Vaporiser, Circle Absorber System With Built In Anaesthesia Ventilator & Withmultipara Monitor Brand - -Drager/Penlon/Bpl General • Should Have Provision For Delivery Of Oxygen, Nitrous Oxide And Medical Air • The Machine Should Be Capable Of Delivering Low Flow Anaesthesia. • The Anaesthesia Machine With Circle Absorber, Ventilator And Vaporiser Should Be From Same Manufactureranaesthesia Machine Should Be Ce Notified Body Approved. • Anaesthesia Machine Should Be Cdsco Approved. Vaporizer Should Be Us Fda Approved.Should Have Independent Attachments For Connecting Central Gas Supply And Pin Indexed Cylindershould Have Non-Interchangeable Pipeline Hose Inlet Connection To Pipelines For Medical Oxygen, Nitrous Oxide, And Medical Air Should Have Large Size Pressure Gauges, For Easy Visibility, Colour Coded, Two Each For Oxygen And Nitrous Oxide; One For Airanaesthesia Machine Frame Shall Be Manufactured In Strong But Lightweight Material.The Machine Shall Have A Maximum Of Four Castors/Wheels For Manoeuvrability With Front Two Castors Having Brakesshould Have Minimum Two Non-Lockable And Spacious Drawers For Storing Accessoriesthe Frame Shall Have Gcx Compatible Channels Incorporated For Mounting Other Accessories. • The Option For An Integrated Independent Oxygen Flow Meter For Oxygen Delivery Is Mandatory. Frame Shall Accommodate Up To Two Backup Cylinders One Each For Oxygen And Nitrous Oxideon Activation Of The System On/Off Switch Gas Flow And Vaporization Shall Immediately Be Availableshould Have Selector Switch For Selecting Open And Close Circuit Operation • The Common Gas Outlet Shall Be Mounted At The Front Of The Machine (Not Rear Or Side) To Be Easily Accessible In The Event Of An Emergency And For Use Of Alternate Breathing Circuits • The Option For Illumination Of The Writing Table/Work Surface Is Mandatory • The Frame Should Have Integrated Power Outlets To Supply A Minimum Of Three External Devices • Should Have Top Shelf, Manoeuvring Handle And Footrest • Machine Should Have Table Topwork Space To Keep Drugs. • The Unit Should Have A Battery Back-Up Facility For The Ventilator In The Event Of Power Loss. Minimum 90 Minutes Battery Backup Required. • Input Power :100 – 240 Vac Gas Flow • Antistatic And Cascaded Dual Flow Tubes Should Be Available For All Gases (O2, N2o& Air) To Allow Suitable Resolution And Accurate Control At Low Total Fresh Gas Flows. • The Flow Range Shall Be 150Ml-10 Lpm • Should Have N2o Cut Off Facility If O2 Supply Fails. • Should Have Oxygen Failure Alarm Both Visual And Audible. • Should Have Oxygen Flush Facility Bypassing Vaporiser. O2 Flush Switch Should Be Conveniently Placed For Easy Accessibility. O2 Flush Switch Should Be Non-Lockable. • The Unit Shall Have A Mechanical Anti-Hypoxic Device (Ahd) System To Control The Ratio Of Oxygen And Nitrous Oxide. A Completely Mechanical Ahd System, That Requires No Electricity, Is Mandatory • The Mechanical Ahd System Must Limit Minimum Oxygen Levels To Approximately 25% • Should Have Minimum Mandatory Oxygen Flow Of 100 Ml When Switched On • It Shall Be Possible To Deliver Air With Only Basal Flow Oxygen Independent Of The Abovementioned Hypoxic Control. • Gas Flow Shall Be Controlled Mechanically Only • Visual Display Of Individual Gas Flows Is Mandatory, This Shall Be By Physical Means Such As Glass Flowmeters Independent Ofelectrical Power • Flow Meters Should Have The Option Of Backlight Illumination • In The Event Of Complete Power Loss And Battery Failure It Shall Still Be Possible To Set The Fresh Gas Flow Accurately For Each Gas, Manually Ventilate (With Bag) And Continue To Keep The Patient Anaesthetized. • Anaesthesia Machine, Vaporizer And Ventilator Should Be From Same Oem. • Provide Isoflurane And Sevoflurane Vaporizer With Themachine. Vaporizers • The Unit Should Accommodate At Least Two Vaporizers For Anaesthetic Agent Delivery. • The Manifold Should Only Accept Vaporizers With Approved Back Bar Connections And Prevent Usage Of More Than One Vaporizer Simultaneously. Preferably Selectatec Compatible Back Bar. • Vaporizers Supplied With The Unit Shall Be Routine Maintenance Free For The Life Of The Product • Vaporizers Supplied With The Unit Shall Be Manufactured From Lightweight Materials To Aid In Fitting & Removal • Should Have An Operating Flow Range Of0.2 – 15 L/Min And Nominal Capacity 250 Ml Ventilator • Ventilator Shall Cater For A Diverse Range Of Patient Groups From Neonates To Adult Patients With Restrictive Airways • Ventilator Should Be Pneumatically Driven And Controlled Electronically • Ventilator Shall Have A Large 8.4” Colourtft Display, For Exclusive Use Of Ventilator Control And Monitoring. • Control Ofthe Ventilator User Interface Shall Be By Touch Screen And Rotary Dialventilator Shall Have The Following Ventilation Abilities, Volume Control (Vcv), Pressure Control Ventilation (Pcv), Simv-V And Simv-P ,Spont/Pressure Support Ventilation (Psv),Manuaassisted Modes Of Breathing Shall Be Flow Triggered. Ventilator Shall Compensate For Fresh Gas Flow And Compliance Of The Entire Circuit. Should Have User Adjustable Alarms For Major Parameters Such As Tidal Volume, Minute Volume,Fio2,Airway Pressure, Frequency Apnea Alarms Must Be User Adjustableto Allow For All Operating Conditions And Phases During Anaesthesia Ventilator Should Have The Ability To Display Patient Spirometry Loop Ventilator Should Also Display Waveforms For Flow, Volume And Airway Pressure Stem Absorber & Not Remoted Via Tubes Or Channelsvolume Measurement Sensors Should Not Be Disposable Typeventilator Parameterstidal Volume- 10Ml-1600 Mlfrequency- 4-100 Bpm I:E Ratio- 4:1 To 1:10 Inspiratory Pause - 0-60% Of Ti Peep - Off, 3-30 Cmh2o Pressure Limit - 5-70 Cmh2o Minute Volume-0.5 To 60 Lpm Breathing System • The Breathing System Designed So That It Can Be Removed & Replaced As A Complete Unit Without The Use Of Tools • All Parts Of The Breathing System That Are In Contact With Patient Gas Shall Be Latex Free And Autoclavable Except For Non Autoclavableremovable Part Like O2 Sensor And Pressure Manometer. • Bag/Vent Switch Shall Be Integrated On The Absorber And Should Activate Ventilator In Vent Mode And Vice Versa (One Step Operation). • Breathing System Should Have Heater System To Avoid Water Condensation. • Should Have Quick Release Canister For Sodalime , Capacity Minimum 1.5 Litre • The Breathing System Absorber Canisters Shall Have A Bypass System To Allow For Canister Change Mid-Case Without Loss Of Ventilation Pressure. The Requirement For An Automatic Bypass Without Extra Input From The User Is Mandatory • The Ventilator Bellows Shall Be Clearly Visible And Be Of Upright Design.The Bellows Should Ascend On Expiration To Provide A Quick Visual Indicator For Assisted Breathing, Spontaneous Breathing And System Leaks. • Same Bellows Shall Be Used For Adult And Pediatric Application • Should Have Provision For Fio2 Monitoring Cell And Fio2 Value Should Be Monitored On The Main Screen. • A Bag Arm With Positional Adjustment Shalmulti Parameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,( Massimo),Nibp (Suntech) Temperature,Dual Ibp, Agm ( Massimo) Mainstream. 3. Should Have 12-Inch Color Lcd Display. 4. Should Have Dual Modes Of Operation: Rotary Knob. 5. Should Display 7 Waveforms Or More 6. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen. 7. Ecg: ? Should Be Able To Monitor Ecg Through 5-Lead Patient Cable ? Should Have Manual St Analysis Window ? Should Detect 20 Arrhythmias And Generate Alarms. ? The Priority Of Arrhythmia Alarms Can Be Configurable ? Should Measure Pvc & Pac ? Should Be Able To Monitor Heart Rate From 10-300 Bpm ? Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etc ? Should Have Pacemaker Detection Facility 8. Respiration: ? Measurement Range Of 0 To 150 Breaths Per Min ? Should Have Gain Selection: ×0.25, ×1, ×2, ×4 ? Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S ? Should Have Apnea Detection Facility ? Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 9. Spo2: ? Should Have Massimo Technology ? Should Have Measurement Range Of 0~100 % ? Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph ? Should Be Able To Select Sat Sec To Avoid False Alarm 10. Nibp: ? Must Be Of Suntech Medical Technology For Clinical-Grade Blood Pressure Measurement ? Should Have Auto, Manual, And Stat Modes Of Operation For Nibp. ? Should Have A Measuring Range Of 0-280 Mmhg 11. Should Have 2 Channels For Temperature Monitoring 12. Should Have Data Storage Capabilities: O 72 Hours Of Trend Data Storage. O 2000 Sets Of Nibp Measurement Data. O 200 Alarm Events O Physiological Alarms Can Be Reviewed With 16 Sec Of Associated Waveform Along With Other Parameter Values. Even Print Out These Waveforms With Optional Recorder O 7 Leads Of Ecg Waveform Disclosure At Least Of 1-Hour O Should Have Facility To Transfer The Trend Data To Usb 13. The Monitor Should Have Drug Dose Calculator And Oxy-Crg View Screens 14. Snapshot Facility With Usb Transfer. 16.Should Have Alarm Settings For All Parameters. 17.Should Have Color Coded Alarms And Alarms Priority Can Be Configurable. 18. Should Have Cns Connectivity Of Same Make. 19.Monitor Should Be Able To Directly Connect With Hospital Information System (His 20.Should Have Standby And Night Mode 21.Should Have Li-Ion Battery 22.Battery Should Have 3.5 Hrs Of Operation 23.Monitor Should Be Ce Certified 24.Manufacturer Should Be Iso Certified 13485:2016 , Bi-Phasic Defibrillator Brand - Bpl/Maestros Technical Specifications For Bi-Phasic Defibrillator • The Machine Should Have Facility For Ecg Monitoring, Bi-Phasic Defibrillation,With Facility To Print Ecg Through In-Built Thermal Printer,• Should Be Extremely Light-Weight (Less Than 10 Kgs) • Should Have Monitoring Facility Through Color Tft Display With Screen Size At Least 7” Or Better. • Should Have Both Synchronous And Asynchronous Mode. • The Defibrillator Should Be Biphasic Technology Based Having Energy Selection Of 2-300 Joules• It Must Be Capable Of Monitoring Ecg Through Ecg Cables, Multi-Function Electrodes And External Paddles. • The Machine Should Be Able To Defibrillate Adult, Paediatric Patients. • The Machine Should Have Ecg Wave Form Display On Bright Screen Along With Other Vital Numeric Information. • Should Be Able To Monitor Ecg• Should Have Facility For Auto Testing When Switched On And During Operations. • The Machine Should Be Compact, Portable With Built In Rechargeable Battery. • Should Have External Pacemaker With Fixed Or Demand Mode. • Should Be Able To Deliver A Maximum Of 300J In Aed Mode • Should Have A Minimum 2 Hours Battery Capacity For Monitoring And 1 Hour Battery Capacity For Giving Minimum Of 100 Shocks.• Energy Selectiononfront Panel Button And External Paddle Buttons • Charge Control On Front Panel Button And External Paddle Buttons • Charge Indicator Charging Tone, End Of Charge Tone, Led In Charge• Shock Control Buttons On The External Paddles • Should Have External Defibrillator Adult And Paediatric Paddles.• Charging Time - Less Than 8 Seconds At 300 J With A New And Fully Charged Battery • The Machine Should Have User Selectable Alarm Settings• The Machine Should Store At Least 24 Events For Viewing Or Recording.Ecg: • Should Be Able To Monitor Ecg Through 5-Lead Patient Cable • Should Be Able To Display Lead I,Ii,Iii, Avr, Avl, Avf And One Of The Chest Leads• Should Be Able To Monitor Heart Rate From 15-300 Bpmgeneral Specifications• The Machine Should Work On Mains As Well As Rechargeable Battery. • The Device Should Be Manufactured From An Iso Certified Organization• Machine Should Be Supplied With Standard Accessories• System Should Be Easy To Operate With Facility To Give Print Command, Charge And Energy Selection On Both External Paddles And On The Main Unit.• Should Have Upgradable Facility For Masimo Etco2.• Should Have Upgradable Facility For Spo2.• Should Have Upgradable Facility For Nibp.• Should Have Upgradable Facility For Pacer Also. , Multi Para Monitor With P, Nibp, Ecg Facility (Brand - Bpl/Maestros/Drager)) Technical Specifications For Multipara Monitor 1. Multi Parameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,( Oxyset+), Nibp (Suntech) Temperature. 3. Optional Parameter Etco2, Dual Ibp, Agm 4. Should Have 12-Inch Color Lcd Display. 5. Should Have Dual Modes Of Operation: Rotary Knob. 6. Should Display 7 Waveforms Or More 7. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen. 8. Ecg: ? Should Be Able To Monitor Ecg Through 5-Lead Patient Cable ? Should Have Manual St Analysis Window ? Should Detect 20 Arrhythmias And Generate Alarms. ? The Priority Of Arrhythmia Alarms Can Be Configurable ? Should Measure Pvc & Pac ? Should Be Able To Monitor Heart Rate From 10-300 Bpm ? Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etc ? Should Have Pacemaker Detection Facility 9. Respiration: ? Measurement Range Of 0 To 150 Breaths Per Min ? Should Have Gain Selection: ×0.25, ×1, ×2, ×4 ? Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S ? Should Have Apnea Detection Facility ? Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 10. Spo2: ? Should Have Nellcor Technology ? Should Have Measurement Range Of 0~100 % ? Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph ? Should Be Able To Select Sat Sec To Avoid False Alarm 11. Nibp: ? Must Be Of Suntech Medical Technology For Clinical-Grade Blood Pressure Measurement ? Should Have Auto, Manual, And Stat Modes Of Operation For Nibp. ? Should Have A Measuring Range Of 0-280 Mmhg 12. Should Have 2 Channels For Temperature Monitoring 13. Should Have Data Storage Capabilities: O 72 Hours Of Trend Data Storage. 2000 Sets Of Nibp Measurement Data. O 200 Alarm Events O Physiological Alarms Can Be Reviewed With 16 Sec Of Associated Waveform Along With Other Parameter Values. Even Print Out These Waveforms With Optional Recorder O 7 Leads Of Ecg Waveform Disclosure At Least Of 1-Hour O Should Have Facility To Transfer The Trend Data To Usb 14. The Monitor Should Have Drug Dose Calculator And Oxy-Crg View Screens 15. Snapshot Facility With Usb Transfer. 16.Should Have Alarm Settings For All Parameters. 17.Should Have Color Coded Alarms And Alarms Priority Can Be Configurable. 18. Should Have Cns Connectivity Of Same Make. , Fully Functional Automatic Dental Chair With Inbuilt Suction And Compressor (Brand- Confident / Chamundi) Programmable Dental Chair, Unit Fitted With Floor Mount Light With Led(Faro, Maia) Operating Light Having, On/Off And Intensity Control By Non-Touchsensor Monitor Mounting Arm High And Low Vacum Motorized Crs Suction System Autocalvable 2 Nos Beecool Ii Light Cure Cordless-1 No Modular Trolley System Over The Patient Airotor Points- 2 Nos Supreme Micromotor 35,000Rpm With Digital Display Of Speed Three Way Syringe- 1 Nos Supreme Optic Scaler With Five Scaling Tips With Endo Chuck 1 No Ss Instrument Tray X-Ray Viewer Multi Function Foot Control Comfort Dental Operators Stool Compressor Monobloc Oil-Free Medical Grade Airotor Air Compressor 1.5/2 Hp With Radiator Cooler, Condensor, Silicon Column Filter For Moisture, Dust Filter Microbial Filter Fitted On Ms Tank. , Dental Aerotor(Brand - Nsk) Push Button With Led Light , Dental Micromotor Contrangle(Brand - Nsk) Latch Type , Dental Micromotor Straight With Led Light (Brand - Nsk) , Round, Straight Surgical Bur For Straight Hand Piece Micromotor Carbide Burs(Brand - Nsk/Prima) , Round, Straight, Inverted Cone And Tapered Fissure Burs For Aerotor Diamond Fg (Brand- Dent Ark) , Rotary Files Niti Files Sx, S1 S2 F1 F2 And F3 (Brand- Dent Ark /Nsk) , Ultraound Color Doppler System (Brand -Samsung Hs30/ Ge Logiq / Mindray Mx7 (3D,4D)/Bpl) Technicalspecification 1. The Units Should Be Latest State Of The Art Digital Color Doppler With Broadband Beam Forming For Cardiac, Abdominal,Vascular And Ob/Gynapplication. The Models With Following (Or Higher) Specifications Need To Be Quoted. 2. The Machines Should Be Usa Fda And European Ce Certified And Should Be Latest In Technology And Launched In 2016 Or Later. The Manufacturing Company Should Be Iso Certified. 3. They Should Have At Least 750000 Digital Processing Channels For High –Resolution Imaging. 4. Imaging Modes : 2D, M- Mode, Color Flow Imaging, Pulse Doppler, Power Doppler, Continuous Wave Doppler And Directional Color Flow Mapping, 3D/4D Imaging Modes 5. The Machine Should Be Supplied With Dedicated 3D/4D Package 6. The Machines Should Have Facility For Simultaneous Dual/ Duplex/ Triplex Mode Display 7. Tissue Harmonic Imaging Should Be Available On All The Transducers. 9. Machines Should Be Capable Of Advanced Real Time Compound Imaging. 10. Should Have Frame Rate 1500 Fps Or More 11. Scanning Depth Should Be 40 Cms Or More 12. High Dynamic Range Of 250 Db Or More. 13. The Machines Should Have 256 Grey Shades (8 Bit) Or More. 14. One Touch Image Optimization Should Be Available In 2D Mode With One Button Automatic Adjustment Of Tgc And Receiver Gain And Compression Curve Based On The Range Of Detectable Tissue Signals. 15. There Should Be One Button Automatic Adjustment Of Doppler Prf, Baseline, Dynamic Range And Gain In Doppler Mode. 16. Pulsed Wave Doppler Should Be Available On All Imaging Transducers With Adjustable Sample Volume Size, Simultaneous Or Duplex Mode Of Operation, Simultaneous, 2D, Colour Doppler, Pulsed Doppler, High Prf Capability In All Modes Including Duplex And Triplex And Automatic Adjustment Of Scale And Baseline. The System Should Have Option To Adjust The Color Flow Mode For High Or Low Flows In One Touch. 17. Machines Should Support Broad Band/ Wide Band High Density Probes Spanning With Frequency Range From 1-20 Mhz (+/- 1 Mhz). The System Should Support Latest Technology Single Crystal Probe Or Matrix Array Probes For Better Resolution And Penetration. 18. Automatic Doppler Analysis Should Be Available With Automatic Real Time Calculation Of At Least Sixof Following User Selectable Parameters Peak Systolic Velocity End Diastolic Velocity, Mean Diastolic Velocity, Volume Flow, Time Average Mean Velocity, Time Average Peak Velocity, Resistive Index, Pulsatility Index, Systolic/ Diastolic Ratio, Acceleration/ Deceleration Times. 19. The Machine Should Have Up To 500000 Images Storing Facility And Cine Loop Review Facility With Memory Up To Minimum Of 25,000 Frames 20. The Machines Should Have Facility Of Direct Storage And Retrieval Of B/W And Color Images (Both Frozen And Cine Loop) In The Inbuilt Hard Disk Drive. In Built Hard Disk Storage Should Be Equal To Or More Than 1Tband Solid State Device In Addition With Capacity 120Gb. 21. The Machines Should Support Four Or More Transducers With Universal Ports Allowing Any Transducer To Be Connected To Any Port. 22. Machines Should Have A High Resolution Fully Articulating Non-Interlaced Flicker Free, Anti-Glare Led Display Of 21 Inches Or More With Resolution 1,920X 1,080 Or Better.In Addition, The Machine Should Have 10” Or More Touch Control Panel For Easy Access. 23. The System Should Have Image Enhancement Options Like Speckle Reduction, Spatial Compounding And Filtered Tissue Harmonics. The System Should Have Adaptive Blending Color To Maintain The 2D Resolution While Working In Color Mode. 24. Zoom Facility (Upto 8 Times Or More Magnification) With High Resolution Results And Pan Capacity In Both Real Time And Frozen Images. 25. The System Should Have Cd-Dvd And Usb Archival (Dicom And Pc Format).There Should Be 4 Or More Usb Ports. 26. Machine Should Be Offered With The Following Broadband Probes (I) Cardiac Package Along With Adult Phased Array Transducer With Frequency Ranging 1.0 - 5.0Mhz (+/- 1.0Mhz). (Ii) Convex Transducer Frequency Ranging ( C1-6Ct) Mhz. (Iii) Liner Transducer Frequency Ranging (L3-12T ) Mhz (Iv) Tvs Transducer Frequency Ranging (Ec3-10T) 27. Online 1Kva Upsand Color Inkjet Printer 28. Preference Would Be Given To Products Manufactured In India, Japan, Korea, Europe, Us. , Laproscopic Surgery Set With Hysteroscope And Resectoscope (Brand Ethicon/ Mindray Medical Pvt Ltd/ Karl Storz/ Conmed/Olympus) Unit And Camera Head The System Should Have The Full Hd Resolution-1920 X1080 Internal Medical Grade Recorder For Capturing Full Hd Videos And Full Hd Stills With Storage Capability Internal Of 50 Gb Or External Medical Grade Recorder Should Be Provided From The Same Manufacturer. System Should Have The Facility Of Controlling The Recording Device From The Camera Head. Video Scopes Can Be Connected To The Same. The Camera System Should Be Able To Provide With 1080 P Lines For Hd Resolution Image. Technical Specifications: Image Sensor: 1 Xcmos Agc: Microprocessor Controller Weight: 130Gm Focal Length: 16Mm Control Buttons: 3 (2 Of Them Freely Programmable) Input: Keyboard Input For Character Generator. Power Supply:-100-240 Vac 50/60 Hz Certified To: Iec 601-1, 601-2-18, Csa 22.2 No. 601, Ul 2601 And Ce According To Mdd, Protection Class1/Cf 2 High-Definition Medical Grade Monitor Led Crystal Display. Max. Resolution Of 1920X1080. Screen Diagonal - 27Inches Desk Top With Pedestal. Should Have The Facility Of Pip Mode. Accessories External 24Vdc Power Supply, Mains Cord, Pedestal. Certified To: En 60601-1, Protection Class Ipx 1 Led Light Source With Fiber Optic Cable Color Temperatures 6400K External Light Source Light Outlets - 1 Light Intensity Adjustment: - Continuously Adjustable Manually From Light So Should Be Supplied With Light Cable, Diameter 4.8Mm, Length 250Cm. Certified To :- Iec 601-1 & Ul 544 Ce According To Mdd, Protection Class 1/C Telescopes Forward Oblique 30 Degree Telescope, Diameter 10 Mm, Autoclavable, Length Optic Light Transmission Incorporated. Forward Oblique 30 Degree Telescope, Diameter 5 Mm, Autoclavable, Length 2 Optic Light Transmission Incorporated Co2 Insufflator Technical Specifications: Gas Flow: 0-400 L/Min Cv 625 Laprascopy Set Pressure: 0-30 Mmhg (4000Pa). High Flow Mode (0 To 40 L/Min.) Sensitive Mode Pressure 15 Mm Hg & Flow 15 L/Min For Sensitive Application Electronic Control And Colour Touch Screen, Following Data Are Displayed On Touch Screen: -Insufflation Mode. Set Value Pressure (0-30 Mmhg). Current Patient Pressure. Set Value Gas Flow (0-40 L/Min). Current Gas Flow. Gas Consumption (0-999 1). Reusable Insufflation Tube For Co2 Gas Up To Patient Body. High Flow Mode With Flow Performance Up To 40 L/Min. Easy And Intuitive Use With User Friendly Color Touch Screen 7 Inch For Easy And Precise Setting Of Set Values For Pressure And Flow And Of Insufflation Mode, As Well As For Clear Display Of Corresponding Set Values And Actual Values. Optical And Acoustic Alarm Signals In The Event Of Patient Overpressure Should Have Hose Pipe. Equipment Cart From The Same Manufacture Should Be Quoted With 4 Or More Helves Isolation Transformer Co2 Cylinder Holder Laparoscopic Instruments- Detailed Description • Veress Pneumoperitoneum Needle With Spring Blunt Stylet, Luer-Lock, Length 13 Cm & 15 Cm –2 Nos • Trocar, Size 11 Mm, Color Code: Green, Consisting Of: Trocar Only, With Pyramidal Tip Cannula Without Valve, With Insufflation Stop-Cock, Length 10.5 Cm Multifunctional Valve, Three Part Dismantel, With Washers Pack Of 10 – 4 Nos • Trocar, Size 6 Mm, Consisting Of: Trocar Only, With Pyramidal Tip Cannula Without Valve, With Insufflation Stop-Cock, Length 10.5 Cm Multifunctional Valve, Three Part Dismantel With Washers Pack Of 10 – 4 Nos • Reduction Sleeve, 11/5 Mm – 1 Nos • Reducer 11/5 Mm– 1 Nos • Telescope, Diameter 10 Mm, Length 32 Cm, Autoclavable, Variable Direction Of View From 0°-90, Adjustment Knob For Selecting The Desired Direction Of View, Fiber Optic Light Transmission Incorporated- 1 Nos •Injection Needle, Luer-Lock, Diameter 1. 2 Mm, Size 5 Mm, Length 36 Cm - 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 3 6 Cm, Right Angled, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Insert, And Outer Tube, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Long, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting- And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Alligator Jaws, Double Action Jaws, Consisting Of: Plastic Handle Without Ratchet, With Larger Contacact Area, Insert And Outer Tube, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Siz E 5 Mm, Length 36 Cm, With Connector Pin For Unipolar Coagulation, Atraumatic, Jaws With Multiple Teeth, Fenestrated, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Atraumatic, Jaws With Multiple Teeth, Fenestrated, Long, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, 2 X 4 Teeth, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle With Manhes Style With Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Bowel Grasper, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area Outer Tube, Insulated., Three Parts Dismantle 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Cleaning, Single Action Jaws, Atraumatic, Fenestrated, Curved, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet Metal Outer Sheath, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Atraumatic, Fenestrated, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Insert And Outer Tube, Three Part Dismantel. 1 Nos • Three Plece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Heavy, Double Action Jaws, Consisting Of: Plastic Handle, With Manhes Style Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel – 1 Nos • Three Plece Scissor, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Deaning, Double Action Jaws, Curved, Length Of Blades 15 Mm, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Insulated, Without Ratchet Metal Outer Sheath, Insulated Scissors Insert For Use With Trocars Size 6 Mm Three Part Dismantel 1 Nos • Single Use Scissor Insert Pack Of 10 (1X10) 1 Nos • Three Piece Laparoscopic Hook Scissors, Rotating, Size 5 Mm, Length 36 Cm, Jaws Not Crossing With Connector Pin For Unipolar Coagulati On, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Outer Tube, Insert, Three Parts Dismantel 1 Nos • Three Plece Laparoscopic Autoclavable Grasping And Dissecting Forceps, Single Action Jaws, Fenestrated, 360 Degree Rotational Sheath, Size 5 Mm, Length 36 Cm, Long, Ergonomic Metal Handle With Plastic Finger Rings With Larger Contact Area At The Finger Ring To Avoid Pressure Sores, Can Be Dismantled With The Press Of A Button. 1 Nos • Suction And Irrigation Tube, Anti-Reflex Surface With Two-Way Stopcock, For Single Hand Control, Size 5 Mm, Length 36 Cm 1 Nos • Olsen Suction Or Irrigation Tube, With Protection Basket, With Trumpet Valve, Size 10Mm Length 36Cm. 1 Nos • Dissecting-Electrode, L-Shaped, Size 5 Mm, Length 36 Cm, With Connector Pin For Unipolar Coagulation, Consisting Of: Outer Tube, Insulated Plastic Handle Electrode L-Shaped With Trumpet Handle 1 Nos • Coagulating And Dissecting Electrode, L-Shaped, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Working Length 36 Cm 1 Nos • Coagulating And Dissecting Electrode, Spatula-Sheaped, Blunt With Connector Pin For Unipolar Coagulation, Size 5 Mm, Working Length 36 Cm 1 Nos • Macro Needle Holder, Ergonomic Axial Handle With Disengage Able Ratchet, Ratchet Release On The Right Side, Left Curved Jaws, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm 1 Nos • Macro Needle Holder, Ergonomic Pistol Handle With Disengage Able Ratchet, Ratchet Release On The Right Side, Right Curved Jaws, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm 1 Nos • Dismantling Needle Holder, Ergonomic Pistol Grip With Disengage Able Ratchet, Ratchet Release On The Left Side, Jaws Curved Left, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm Consisting Of: Insert, Outer Tube, Handle 1 Nos • Unipolar Hf Cord With 4Mm Banana Plug And Length 300 Cm 1 Nos • Clip Applicator, For Use With Ethicon Titanium-Clips Lt-300 (Medium Large), Dismantling, Rotating, With Ratchet To Lock The Jaw Part Holding The Clip, Size 10 Mm, Length 36 Cm, Consisting Of: Metal Handle, With Ratchet Metal Outer Tube Insert, Three Part Dismantel, 1 Nos • Claw Forceps, Rotating, Size 10 Mm, Length 36 Cm, 2 X 3 Teeth, Single Action Jaws, Consisting Of: Metal Handle, With Manhes Style Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Claw Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, 2 X 3 Teeth, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area Outer Tube 1 Nos • Rotatable Bipolar Grasping Forceps, Rotating, Dismantling, With Connector Pin For Bipolar Coagulation, Double Action Jaws, Especially Suitable For Dissection, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet, Color Code: Light Blue Outer Sheath Forceps Insert, Three Part Dismantel. – 1Nos • Rotatable Bipolar Grasping Forceps, Rotating, Dismantling, With Connector Pin For Bipolar Coagulation, Double Action Jaws, Fine Atraumatic Serration, Fenestrated, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet, Color Code: Light Blue Outer Sheath Forceps Insert, Three Part Dismantel. – 1 Nos • Bipolar Hf Connecting Cable Length 300 Cm, Compatible With All Standard Cauteries – 1 Nos • Fascial Closure Instrument For Sub Cutaneous Ligature Of Trocar Incisions – 1 Nos • Myoma Fixation Instrument, Screw Shaped, 5 Mm. – 1Nos • Dismantling Fan Retractor, Distendable, Size 5 Mm, Length 36 Cm.- 1 Nos • High Frequency Needle, For Splitting And Coagulation, Insulated, Retractable, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 31 Cm. 1 Nos • Single Use Scissor Insert Pack Of 10 (1X10) - 1 Nos • Uterine Manipulator: Uterine Manipulator For Providing Tissue Tension Needed For Anatomical Surgery. The Manipulator Should Have Application In Tlh, Lash, Lavh And Hysterectomies For Malignant Pathologies 1 Nos • Sterilization Tray For 2 Telescopes (Same Manufacturer) • Sterilization Tray For Instruments (Same Manufacturer) Hysteroscopy Set Hysteroscope Sheath For Diagonostic Continuous Irrigation Size 6.1-6.3Mm Outer Sheath And 5.1-5.3 Mm Inner Sheath For Use With 4Mm Hysteroscope Telescope. Hysteroscope Sheath For Operative Continuous Irrigation Size 5.9-6.1Mm Outer Sheath With Operating Channel 5Fr, Leur Lock Adaptor And 5.3-5.5Mm Inner Sheath For Use With 4Mm Hysteroscope Telescope. With Stopcock & Leur Lock Adaptor And Inflow And Outflow Channe Semi Rigid Instruments For Use With Operating Hysteroscope Scissors Semi Rigid, Blunt Tips, 5 Fr., Length 36-40Cm, Single Action Jaws Scissors Semi Rigid, Pointed Jaws, 5 Fr., Length 36-40Cm, Single Action Jaws, Semi-Rigid Biopsy- And Grasping Forceps Semi Rigid, 5 Fr., Length 36-40Cm, Double Action Jaws Tenaculam Grasping Forceps Semi Rigid, 5 Fr., Length 36-40Cm, Double Action Jaws Bipolar Vaporization Electrode, Semirigid, 5 Fr., Needle Electrode Angled 90°, Length 42Cm Bipolar High Frequency, Should Fit In Most Of The Standard Electrosurgical Unit Having Bana Plug One Side, Length Should Be Not Less Than 250Cm Telescope 12, Enlarged View, Diameter 4 Mm, Length 30 Cm, Autoclavable, Fiber Optic Light Transmission Incorporated Bipolar Working Element To Be Used With 26 Fr Resectoscope Sheath: Motion By Means Of A Spring. The Thumb Support Is Movable. Return Of The Loop Is Control By The Thumb And In Rest Position The Electrode Should Rest Inside The Operating Sheath, To Be Used With 4Mm Hysteroscopy Telescope. Should Work In Saline Bipolar Cutting Loop 24 Fr Should Work In Saline Cutting Electrode 24Fr, Bipolar, Pointed, Should Work In Saline Coagulating Electrode 24Fr, Bipolar, Ball End Should Work In Saline Continuous Flow Resectoscope Sheath 26 Fr., For Bi-Polar, Including Connection Tubes For And Outflow, 2 Luer-Lock Adaptors, 26Fr, Oblique Beak, Rotating Inner Tube, With Ceramic Insulation, For Use With Working Element. Should Work In Saline Obturator, For Use With The Resectoscope Sheath. Fluid Management System (Irrigation & Suction Unit) Pressure Regulated Suction And Irrigation System For Use In Laparoscopy And Gynaecology Unit Should Have Touch Screen As User Interface. Unit Should Have Feature Of Automatically Fixing Maximum Parameters For Laparoscopy And Hysteroscopy Mode By The Choice Of Tubing Unit Should Have Feature Of Simultaneous Display Of Set Values And Actual Values Enabling User For Continuous Monitoring Of Suction And Irrigation Parameters Unit Should Have Feature Of Use Of Disposable/Reusable Cassette Tubing Set For Laparoscopy/Hysteroscopy Procedures. Unit Should Be Supplied With Glass Suction Bottle 5 Lite Unit Should Have Pressure Settings: Hysteroscopy Mode: 0-200 Mmhg Laparoscopy Mode: 100/300/500 Mmhg Unit Should Have Flow Settings: Hysteroscopy Mode: 200/400/600 Ml/Min Laparoscopy Mode: 0-1300Ml/Min Suction Pressure Regulated: Hysteroscopy Mode: 0.1-(-)0.8Bar (-80Kpa) Laparoscopy Mode: 0.1-(-)0.8Bar(-80Kpa) Power Supply: 100-240Vac, 50/60Hz Certified To: Iec 601-1, Ce Nach Mdd Certified To: Iec 601-1, Ce Acc. To Mdd Note: - All The Above Items Should Be Usfda And European Ce Certified And From Same Manufacturer For Better Compatibility And Maintenance , Integrated Electrosurgical Unit And Vessel Sealer Brand -Ensurge/ Hti Digital / Kls Martin / Enertech/Shalya Specifications For Integrated Electrosurgical Unit And Vessel Sealer 1) Advanced Electro Surgical Unit With Vessel Sealing System Have Mono Polar Cut & Coagulation, Bipolar And Vessel Sealing Technology, All Integrated In Single System 2) Type Of Display Should Be Lcd Touch Screen 3) Display Size Should Be 5” Or More 4) Unit Should Have Microprocessor-Controlled Tissue Feedback Technology. 5) The System Should Have Capability To Convert Electrical Energy To Radio Frequency Energy Thus Providing Radio-Frequency Seal 6) Number Of Tissues Sensed Per Sec Should Be 4000 Or Higher 7) Vessel Fusion System Must Be Able To Seal Artery, Veins Along With Tissue Bundle Up To & Including 7Mm In Diameter & Sealed Vessels Should Be Able To Withstand At Least 3 Times The Systolic Blood Pressure. 8) Low Frequency Leakage Should Be 50 Or Higher (In Ma) 9) High Frequency Leakage (Rf) Must Be Less Than 100Ma In Mono Polar And Vessel Sealing Mode And Less Than 70Ma In Bipolar Mode 10) Should Be Provided With Rs 232 Data Input Port For Software Upgrade Facility 11) System Must Have Recall Facility To Recall The Last Setting Used By User Before Turning Off The Power Directly Or Through User Programs. User Can Use Pen Drive With Their Setting To Recall The Setting Saved By Them. 12) System Should Have Bipolar Resection Including Under Water Cutting. 13) The System Should Be Provided With Twin Monopolar Socket (Only One Socket To Be Activated At A Time) With Independent Power Setting 14) 5 Or More Numbers Of Cutting Modes Available In Monopolar 15) Maximum Power Should Be 400W Or Higher 16) Maximum Power Of Blend Mode For Cutting With Homeostasis Should Be Not Less Than 250W 17) Fulgurate/Forced Mode, Spray Mode, Soft Mode Of Monopolar Coagulation Should Be Available. 18) Unit Should Be Supplied With 4 Or More Nos. Of Monopolar Coagulation Modes 19) Coagulation Mode Power (Monopolar) Should Be 150W Or Higher 20) Coagulation Mode Power (Bipolar) Should Be 120W Or Higher 21) Number Of Bipolar Cutting Modes Should Be Or Greater Than 5 22) Maximum Power For Ligation Not Less Than 100W 23) Maximum Power For Resection Not More Than 300W 24) Equipment Should Have On Screen Review Of Error Codes And Diagnostics. 25) System Should Have Patient Plate Contact Quality Monitoring System Giving Audio-Visual Alarm And Deactivating Output If Contact Between Patient And Patient Plate Is Not Proper To Eliminate The Risk Of Patient Burns. It Should Be Mandatory, Should Have Contact Quality Monitoring With Split Style Patient Return Electrode And Deactivates Output If Contact Between Patient And Patient Return Electrode Is Not Proper To Eliminate The Risk Of Patient Burns, Manufacturing By Same Oem 26) Auto Bipolar Start And Stop Along With User Configurable Auto Start Facility Should Be Available 27) Power Output Of Vessel Sealing System (Vss) Not More Than 150W 28) Vessel Sealing System Should Be Able To Seal Vessels Or Tissue Bundles Faster Than Any Conventional Devices (Preferably Within 2-4 Seconds) 29) Product Should Be Ce Certified (4 Digit Notified Body). 30) It Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification & Iso 9001: 2008 & Iso 13485:2003 Certified Company. 31) Warranty Of The Unit Should Be 5 Years 32) It Should Be Supplied With All Following Accessories, Should Be Reusable And Autoclavable: - O Patient Return Electrode --- 1 No. O Cable For Return Electrode --- 1No. O Hand Switching Pencil --- 1 No. O Foot Switching Pencil --- 1 No. O Double Pedal Footswitch With Toggle Function (Common/Individual For Monopolar, Bipolar And Vessel Sealing) - 3 No. O Universal Adaptor --- 1 No. O Bipolar Forceps --- 1 No. O Cable For Bipolar Forceps --- 1 Nos. O Set Of Electrode (Angled, Ball And Needle) ------ 1No. O Reusable Sealing Clamp With Cable--- 1 No. O Curved Jaw Vessel Sealer 5 Mm, 32 To 37 Cm -- 1 No. O Autoclavable Reusable Cutting Instrument – 1 No. Additional Terms & Conditions: 1. Vessel Sealing Laparoscopy Instruments Should Have Both Hand And Foot Activation Mode And Should Be Eu Ce (4 Digit Notified Body Certified) Or Usfda Approved. 2. All Sockets Should Be Of Blinking Light Type When In Use To Identify The Used Mode. 3. R.F. Frequency Should Be In Between 350-500Khz For All Modes. 4. It Should Have Bipolar Rf Scalpel Mode For Dissection & Desiccation. Rf Bipolar Scalpel Instruments Should Have Hand Control Button For Coagulation & Cut. 5. Equipment Should Be Usfda Approved/ Eu Ce (4 Digit Notified Body Certified). It Should Have Iec-60601-1- 1, Iec 60601-2-2 Safety And Des , Ctg Machine Brand - Bpl/Maestros/Bistos Specification Foetal Monitor With Display And Printer Should Have 12.1” High Resolution Colour Tft Display With Tiltable Screen For Better Viewing. Should Display Fhr, Toco, Foetal Movementin Numeric Values . Should Display 2 X Fhr And Toco Graphs In Different Colours. Should Have The Facility For Data Save With Play Back & Print Facility Should Have Facility To Monitor Information Of Last 25 Hours Should Have Special High Sensitive Watertight Probe For Better Durability Should Have The Low Ultrasound Power For The Safety Of The Foetus Should Have Automatic Foetal Movement Detection Should Have Event Marking Facility By Mother And User Thermal Printer With Minimum 152Mm Paper Width Is Essential For Broader Printouts Standard Configuration Should Be Fhr, Toco, And Foetal Movement Should Have Volume Control For Fhr Beep Sound And Alarm. Should Have Alarm Setting For Weight Should Be Less Than 4 Kg For Easy Portability. Should Have Foetal Stimulator Built In To Fhr Probe And Activation Key Should Be There On The Front Panel. Stimulation Should Be Recorded On The Recording Paper And Should Be Displayed On The Screen. Built In Rechargeable Li-On Battery For Backup Should Work With Input 200 To 240Vac 50 Hzsupply Central Monitoring System Software Upgradability Should Be Possible (Optional) Should Be Supplied With The Following Standard Accessories: Power Cord- 01 Fhr Probes – 01 Nos Toco Probe -01 Patient Event Marker Belts – 02 Nos Gel – 1 Bottle Thermal Paper- 02 No , Digital Video Colposcope Brand - Bpl/Maestros/Bistos Specification 1. Should Have Led Cold Lighting System Reproduces An Original View Of Tissue. 2. Led Lights Are Replaceable. 3. Should Have Advanced And Fast Auto-Focusing System To Ensure Clear Image. 4. Should Have Remote Capture Control And User-Friendly Keyboard Layout For One Handed Operation. 5. Should Have Electronic Green Filter That Enhances Vascular Image Display Without Compromise Of Illumination. 6. Should Have Working Distance Of 6.7 - 11.8 (170 - 300 Mm). 7. Should Have Magnification Of 1X - 36X. 8. Should Have Resolution Of 3,80,000 Pixels Or More 9. Should Have Horizontal Resolution Of > 470 Lines. 10. Should Have Field Of View Of 0.4 - 5.9 (10 - 150 Mm). 11. Signal/Noise Ratio Should Be = 50 Db. 12. Should Have Signal Output Of S-Video, Pal/Ntsc. 13. Should Have Acetic Acid And Iodine Reaction Test Timer To Precisely Detect Low/High Grade Cin. 14. Should Have Real-Time Display Of Magnification. 15. Should Have Powerful Colposcopic Findings Gallery For Comparison Analysis. 16. Should Have R-Way Evaluation Program Supports Cervical Disease Diagnosis Guidance For Clinical Users. 17. Should Have Dicom 3.0 Supportive. 18. Should Be Manufactured By An Iso Certified Company , Vessel Sealing Device For Open Surgery Shaft Length-23Cm Curved Tip (Box Of 6)(A) Curved Jaw Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology. Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A} Curve Jaw Vesselsealer B) Should Be Able To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. C) Sealing Should Withstand 3 Times Systolic Pressure. D) Scaling Length 20 Mm; Cutting Length 18 Mm, Shaft Length 23 Cm; Shaft Diameter 5 Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. Technical Specification For , Vessel Sealing Laparoscopic Surgery, Shaft Diameter-5Mm, Length-37 Cm Jaw Type Curved Jaw Double Action With Contoured Tips, Shaft Rotation 350 Degrees, Jaw Surface-Textured Ceramic Stops.Jaw Aperture-13Mm Seal Plate Length- 20.3(Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Blunt Tip Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Sealing Length 20 Mm; Cutting Length 18 Mm, Shaft Length 37 Cm D) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness:Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. E) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Instrument For Open Surgery, Instrument Length 20.6Cm-21 Cm, Curved Jaw, Hand And Foot Switching(Box Of 6). Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Exact Open Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Instrument Length Should Be 21 Cm. D) Curved Jaw In 28 Degrees, Seal Length 19.3Mm, Cut Length: 18.5Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Device Laparoscopic Surgery. Shaft Diameter-5 Mm, Maryland Jaw Curved Device Length 37Cm (Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Curved Jaw Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec B) Sealing Should Withstand 3 Times Systolic Pressure. Scaling Length 20 Mm; Cutting Length 18 Mm, Shaft Length 37 Cm; Shaft Diameter 5 Mm C) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation D) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Device For Open Surgery With Shaft Length 18.8 Cm, Jaw Type-Curved Jaw (Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Small Jaw Open Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Instrument Length Should Be 18.8 Cm. D) Curved Jaw In 28 Degrees, Seal Length 16.5Mm, Cut Length: 15.5Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Ethelene Oxide Sterlization Machine ( Brand - Steri Techno Fab/ Map Industries) 1) Eto Gas Sterilizer Should Be Fully Automatic Type With Software-Controlled Operation System For Low Temperature Sterilization Of Heat And Moisture Sensitive Medical And Surgical Items. 2) The Chamber Should Be Preferably Rectangular With Capacity Of 250 Litters Or 9 Cu. Ft. & Dimension 48”(L) X18”(W)X18”(H). 3) The Operating System Should Be Programming Logical Controller Based And Should Have Touch Screen Human Machine Interface From Where User Should Operate And Observe The Cycle . 4) The Inner Surface Should Be Smoothly Finished To Minimize Gas Deposits. 5) Manufacturer Should Provide The Test Report To Prove Conformity To Specification And Ability Of Eto Unit To Achieve Complete Pathological/Microbiological Elimination. The Test Of Report Has To Be Attached With Technical Bid Document. 6) Surface Heaters Should Mount On The Chamber For Uniform Temperature In Chamber Throughout Cycle. 7) Less Noisy And Vibration Proof Vacuum Generator Should Be Provided For Vacuum Instead Of Vacuum Pump. 8) The Machine Should Be Provided With Plc Based Automation Along With Lcd Hmi Which Allows The Operator For: (A) Change And Set The Parameters (B) Run The Cycle According To Pre-Selected Cycles. (C) Monitor Various Phases / Individual Parameters During The Process. (D) View On/Off Status Of The Various Components Of The Machine While The Cycle Is In Progress. 9) It Should Have Password Protection For Unauthorized Access & Analogue Input Of Process Pressure/Vacuum. 10) It Should Have Digital/Analogue Input For Temperature & Temperature Should Be Indicated In The Sterilization Area, By The Use Of A Temperature Sensor. 11) One Pressure/Vacuum Sensor For Display Of The Current Pressure/Vacuum, That The Load Should Be Subjected To, At All Times During The Process. 12) The Software Should Provide & Maintains Total Records Required For Process Parameters During The Sterilization Cycle. These Records Are Necessary For Meeting Ce Or En 1422 Norms Of Sterilization. 13) All The Fittings For The Accessories And The Main Vessel Should Be Fabricated From Ss 304 Stainless Steel. All The Valves Used In The Process Lines Should Be Ss 304/Brass/Teflon Construction Ball Valves. (All Standard Makes) 14) Pressure Testing And Vacuum Testing As Per Specified Standards. (1.5 Times The Working Pressure) 15) Automatic Operations As Well As Manual Operations In Case Of Technical Problems Should Be In Plc/Hmi. 16) Machine Should Not Open During Sterilization Process, It Should Be Open Only After Complete Cycle Of Sterilization. 17) It Should Be Plc Based Automation System. Plc Should Be Honeywell Or Siemens. System Should Be 21 Cfr Compliances. 18) Automation Should Be 7’’ Touch Screen Display Of Schneider Or Proface Or Equivalent. 19) The Construction Of Chamber Should Be Of Ss316 Grade Stainless Steel. 20) There Should Be Interlocks With Door Mechanism So Cycle Should Start Only After Closing Of Door. 21) Cartridge Puncture Operation Should Be Automatic Into The Chamber No Need Of Manual Puncturing. 22) In Case Of Cartridge Puncture There Should Be Alarm System. 23) One Complete Cycle Should Be Containing All Phases. Time Based Parameter Should Be Mention In Non-Editable Data Sheet. 24) Temperature, Pressure, Humidity, And Other Parameters Should Be Display In Hmi Screen. 25) It Should Be Noise Proof And Vibration Proof Vacuum Generator Should Be Provided For Vacuum Instead Of Vacuum Pump. 26) It Should Be In Built Aeration Phase To Remove Residual Gas Out From Sterile Item. 27) Pre-Requisite Sequence Phases Should Define To Run Cycle In Auto Mode. 28) Pre-Sterilization Phases Should Define To Create Proper Condition For Sterilization (I.E. Humidity& Temperature). 29) Post-Sterilization Phases Should Define To Remove Residual Gas From The Product. 30) Machine Should Have Manual Override Operating Facility. 31) Accessories Needs To Be Supplied With Machine: - ? Suitable Air Compressor Of 1 Hp Capacity. Air Compressor Should Be Oil Free And Less Noisy As Compared To The Traditional Oil-Based Compressor. ? 1 Nos Wire Mesh Type Basket For Loading & Un-Loading Of Sterilization Materials. ? Manual Sealing Machine Suitable Medical Use Sealing. Machine Should Operate On 240 V/50 Hz Operated And Make In India Product. Eto Gas Cartridge Of 1 0 0 Grams- 1 0 Nos. Eto Cartridge Should Be Of Same Make Of Machine. Bidder Must Have To Attach Msds Sheet Of Eto Gas Cartridge With Bid Document. 32) The Manufacturer Shall Have Below Listed Certification To Prove His Eligibility And Copy Of The Certificates Should Be Enclosed With The Offer. ? Iso 9001:2015 For Quality Management System. ? Ce Certificate For Eto Sterilizer & Eto Cartridge Compliance With The Requirement Of Directive Council Directive On Medical Devices 93/42/Eec As Amended 2007/47/Ec. ? Quality Management System For Medical Devices Iso 13485:2016 For Eto Sterilizer & Eto Cartridge. ? Risk Management To Medical Devices Iso 14971:2007 For Eto Sterilizer & Eto Cartridge. ? Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use - Part 2-040: Requirements For Sterilizers And Washer Disinfectors Used To Treat Medical Materials Iec 610102-040:2020 & Iec 61010-1- 040:2020. ? As Eto Gas Toxic And Carcinogenic Properties Environment Management System Certificate. ? Medical Electrical Equipment Iec– Part 1-2: Requirement For The Basic Safety And Essential Performance Of Multifunction Patient Monitoring Equipment. ? Iso 45001:2018 For Occupational Health And Safety Management System. ? Iso 20857:2010 And Rohs Directive (2011/65/Eu) On The Restriction Of Use Of Certain Hazardous Substances In Electrical And Electronic Equipment. ? Fda & Who-Gmp Certificates To Prove Standard Of Manufacturing Practice , Ot Light ( Brand - Shalya/Mattrix/Surgident) Description Of Function Led Surgical Lights Illuminate The Surgical Site For Optical Visualization Of Small Low Contrast Objects At Verifying Depths In Incisions And Body Cavities. 1. General Requirements 1.1. The Light Shall Adopt Led Technology To Create A Homogenous Light Patch Without Emitting Any Infrared Rays. 1.2. The Light System Shall Be Dual Light Heads, One Major And One Satellite. 1.3. Light Should Have Electronic Focusing From Control Panels Without Any Motorized Or Mechanical Movement Of Light Panels. 1.4. All Dome Should Have 2 Colour Led Lamps, White (Cool White) & Amber (Warm White) To Achieve High Cri And Get The Required Shade Of Light As Per Different Surgical Requirements. 1.5. High Power Leds Of 5Watts & Above Should Be Used To Provide High Lumen To Watt Ratio Which Leads To Lesser Energy Consumption And Low Heat At Surgical Area <2 Deg. 1.6. Lights Should Have Higher Watts Leds To Achieve High Lumen To Watt Ratio Which Leads To Lesser Energy Consumption And Low Heat At Surgical Area. 1.7. Pulse Width Modulation-Controlled Led Driving To Ensure Less Heating Of Led Which Increases Life Of Leds And No Change In Light Colour Output And Light Colour Temperature Throughout Life. 1.8. The Major System Shall With Automatic Illumination Control System With Sensors On The Light Head. When Some Part Of Led Is Masked By Surgeon’S Head Or Shoulders, The Remaining Led’S Will Become Brighter Automatically To Compensate For The Losing Illumination. 1.9. Light Intensity Shall Be Adjustable Between 30% -100% And Should Have Low Intensity Light For Endoscopy Mode. Light Intensity, Light Field Diameter And Color Temperature Should Be Controlled From Electronic Touch Control Panel Mounted On Light Arm And Wireless Wall Mount Electronic Touch Control Panel. It Should Also Have Provision To Control The Intensity, Electronic Focus, Depth From Sterile Field Though Capacitive Touch Control Handles. 1.10. The Light Head Shall Be Of Petalled / Winged Shape To Avoid Obstruction To Laminar Flow On Surgical Field. 1.11. The Color Temperature Shall Be Synchronized & Controlled By Either Light Head Control Panel. 1.12. The Light Shall Be Mountable To Ceiling From Single Center With 360-Degree Rotation Of All Arms. Spring Arms Shall Be Rotatable At Least 360 Degrees Around Its Own Axis. Each Dome Head Should Be Rotatable With 360 Degree At Connecting Joint With Spring Arm And At Least 300 Degrees Around Its Own Axis. This Feature Should Be Applicable With A Camera Mounted Dome Also. 1.13. The Maximum Movement Angle Of The Spring Arm Shall Be At Least Up 45°And Down 50 1.14. The Thickness Of The Light Head Shall Be No More Than 70 Mm. 1.15. Each Led Shall Be Replaceable Individually To Save Cost In Case Of Failure, Instead Of Replacing The Module With Several Leds. 1.16. The Surgical Light Should Be Complete With All Components For Celling Mount And Electrical Feed-In, Including Finalized Installation. 1.17. Detachable & Auto Cleavable Handle (3 Nos.) For Each Light Should Be Provided. 2. Technical Requirements Of Both Domes: 2.1 It Should Have 2 Colour Led Lamps, White ( Cool White) & Amber( Warm White) 2.2 The Central Illuminance Should Be 160,000 Lux 2.3 Light Field Diameter Should Be Adjustable From 150Mm To 300Mm 2.4 D10: 300Mm & D50 :160Mm 2.5 Color Temperature (K), Adjustable From 3500-5000K 2.6 Color Rendering Index Ra Should Be 95 Or More And R9 Should Be 93 Or More 2.7 Depth Of Illumination (L1+L2) As Per Iec 60601-2-41 (Ver 2003) Should Be 650Mm And As Per Iec 60601-2-41 (Ver 2008) Should Be 1200Mm. 2.8 Dimming Range Should Be Between 25-100% 2.9 Endoscopy Mode Illumination Should Be Less Than 5% Of 160,000 Lux 2.10 Number Of Led Bulbs The Light Head Should Not Be More Than 70 2.11 Led Service Life Should Be Minimum 60000Hrs 2.12 Light Head Dimension Should Be 700Mm (=/- 20Mm) 2.13 Max. Power Consumption Of All Light Sources Should Be Less Than 100W At Maximum Setting. 2.14 Power Supply Should Be 100-240V Ac, 50-60Hz 2.15 One Dome Should Be Ready For The Wireless Camera Attachment. 3.Standards • Iso 9001:2008 • Iso 13485:2003, • European Ce With 4 Digit Notified Body / Eu Ce With Eu Free Sale Certificate /Us Fda Registered . • Should Compliance With: Iec 60601-1, Iec 60601-2, Iec 60601-2-41, Certificate From Any Nabl Accredited Lab / Any Lab From Country Of Origin For Imported Brands , Suction Machine (Electrical) (Brand -Supreme / Goley) Type: Electrical Pump Type: Oil Immersed Rotary Vane Capacity: High Vacuum Voltage: 220 Vac, 50 Hz, 1 Ph Number Of Wheels: 04 (Antistatic) Air Flow: 35 Ltrs/Min Current: 1.8A Noise (Decibel): 30~35 Dba Power Consumption: 370W Weight: 25 Kgs Flow Rate: 35 Lpm Vacuum Gauge: 100Mm Reservoir Volume: 5000Ml Tubing: Non-Collapsible Suction Tubing Max Vacuum: -720Mmhg Motor:½Hp, Fhp 100% Copper Winding Rpm: 1440 Jars: Polycarbonate 2X2.5 Liters Capacity Filter: Bacterial Filter Autoclavable /Reusable Suction Machine Should Be Is I Marked , Fully Automated Biochemistry Analyser Brand (Erba Transia/ Meril) Random Access System With Stat Capability. Analytical Principle Spectrophotometry & Photometry, Turbidometry Principles. Assay Type End Point, Rate, Fixed Point, Kinetic, Ise (Optional). On Board Parameter - Present. Programmable Tests - Present. On Board Cooling For Reagent Present. Through Put - 200 Test/Hour Or More, Continuous Loading Facility. Sample Types Serum, Plasma, Urine & Other Body Fluids. Sample Volume 0-70 Micro Litres (Approx). Sample Quality Analysis, Clot Detection & Probe Crash Protection - Present. Reagent Volume 10 Microlitre To 300 Microlitre (Approx.). Total Reaction Volume 90 Microlitre To 350 Microlitre. Reaction Cuvettes - Permanent Glass Cuvettes With On Board Laundry. Possibility Of Replacement Of Individual Cuvette. Photometric Range 0-3.0 Od. 15. Wavelength-340-800 With Minimum & Standard Wavelengths (340, 405, 505, 546, 578, 600, 700 Nm) Calibration Autocalibration, Cooled Calibration Position, History Of Graphical Calibration Data Stored. Quality Control At Minimum 4 Level Qc Plot Westgard Rules, Twin Plot, Levey Jennings Graph, Cooled Qc Position. Data Storage Of Patient Present Proper System Of Storage Minimum Water Consumption. Warranty 5 Years Warranty Power Back Up Facility For Instrument. Autopipettes To Be Provided With Instrument 10 Micro Litre (Fixed) 01 Nos. 1000 Micro Litre (Fixed) 01 Nos. 0-100 Micro Litre (Variable) 01 Nos. 0-500 Micro Litre (Variable) 01 Nos. 100-1000 Micro Litre (Variable) 01 Nos. Demo Kit With Instrument Reagents Kits Provided With Instrument: Creatinine, Urea Uric Acid, Triglyceride, Sugar Cholesterol, Tp, Albumin, Sgpt, Sgot, Alkaline Phosphatase, Bilirubin Instrument: Usfda Registered And Ce Ivd Approved , Cbc Machine Brand -(Accurex / Erba/ Meril) Measurement Principle Electrical Impedance For Counting Rbc Wsc & Plateletscolorimetric Estimation Of Hgb At 540 Nm Parameterswbc, Ly#, Mid, Gr, Ly%, Mid%, Gr, Rbc, Hgb, Hct, Mcv, Mch, Mchc, Rdw-Cv, Rdw-Sd, Plt, Mpv, Pdw, Pct, P-Lcr, P-Lcc Throughput- 60 Samples/Hour Micro-Aperturewbc: 100 ?M Rbc/Plt:68 ?M Sample Typewhole Blood Or Pre-Diluted Sample Sample Volumewhole Blood (Venous Blood): 10 ?Lpre-Diluent (Capillary Blood) : 20 ?L Chamberdual Chamber: Rbc/Platelets & Wbc/Hgb Reagents- 3 Reagent System: Diluent, Detergent & Lyse (Non-Cyanide) Measurement Range Linearity Range Acceptable Limits Wbc0x10/L-10.0×109/L<= Plus/Minus 0.3 * 10 ^ 9 / L 10.1×109/L-99.9×109/L 0X102/L-1.00×102/L <= (Plus/Minus 5)%<= Plus/Minus 0.05 * 10 ^ 12 / L Rbc 1.01X102/L-9.99X102/L<= (Plus/Minus 5)% Quality Control - 4 Qc Options: L-J, X-B, X-R & X Qc Graphs Plotted With 31 Data Points Data Memory - Upto 100,000 (With Histogram) Display - 10.4 Inch Color Lcd With 640 * 480 Resolution Printer Built-In Thermal Printer Interface:Support Rs-232C, Standard Network Port And Usb; Keyboard And Mouse Operating Environment - Temperature: 15°C-35°C Electrical Specification-Fuse Specification: 250V/3A Humidity: = 85% Rh Frequency: 50/60 Hz Low: 1 X 3Ml/Normal: 1 X 3Ml/High: 1X3 Ml , Sthetoscope Brand- Bpl/Littman , Pulse Oxymeter Brand - Dr Trust /Beurer/ Bpl Specification Finger Chamber With Smart Spring System Accommodates A Wide Range Of Finger Sizes Pop-Up Menu To Setup Alarm Limits For Spo2 And Pulse Rate Low Battery Indicator Pule Rate: Yes Auto Power-Off: Yes Bright, Large Display For Better Visibility In Daylight Anti-Movement Feature Sturdy, Portable And Light-Weight Very Easy To Operate With Single Switch Operation Warranty ( Only Checking Warranty ) , Nebulizer Machine ( Brand -Bpl/Dr Trust) Operation Mode Table Top Size Compact Application Clinical Purpose, Hospital Medicine Cup Capacity 50 Ml Particle Diameter 1-5 Um , Pns ( Pereferal Nerve Stimulator For Nerver Block) Brand- B Braun / Vygon Sas/ Stimuplex Hns/2 Should Be Suitable To Identify Peripheral Nerves And Giving Percutaneous Stimulation In Neuro Muscular Block. - Should Have A Percutaneous Monopolar/Bipolar Stimulating Handle For Localization Of Nerves Without Puncturing The Nerve Which Should Be Autoclavable. - Should Have Selectable Stimulation Intensity Ranging From 0-60Ma In Steps 0.1Ma With Stimulating Handle And Stimulation Impulse Width From 0.3Ms, 0.5Ms And1.0Ms - Should Continuously Measure & Display Actual Current Passing Through The Patient And Selected Current -Should Have Pause Function To Interrupt Stimulation Without Delivering Impulses Test Function -Should Automatically Switch Off With A Acoustic Warning If Not Operated Over A Period Of 20 Mins -Should Have Lcd Display For Stimulation Current, Impulse Pattern, Pulse Width, Impulse Amplitude. - Should Have Analog And Digital Display Of Selected Current And Actual Current. - Should Have Membrane Touch Pads For Choosing Stimulation Function -Should Be Small (Pocket Size) & Light Weight. Should Be Ce Certified Or Usfda Certified , Nerve Locator With Needle Brand- B Braun / Vygon Sas/ Stimuplex Hns/2 Separate Output For Nerve Stimulator - Mapper And Locator For Safety. Automatic Switch Over From Mains Power Adaptor To Rechargeable 9Vbattery With Low Battery Warning Indicator. Feather-Touch Keypad For Easy Operation, Simple Setting And Extended Reliability. Variable Current Range As Per The Selected Mode(Impedane:0 To 5 Kohm). User Programmable Pulse Width And Frequency. Alphanumeric Lcd Display With Back Light. Automatic Shutdown For Power Saving. Audio And Back Light On-Off Option. Alarm: Audio-Visual-Alarm Is Activated If Flow Of Oxygen Falls Below 1Lpm. , Percussion Hammer Ss 304 , Tuning Fork 128 Hz Satinless Steel , Laryngoscope A Laryngoscope Is A Device Used In Medical Procedures To Visualize The Trachea By Inserting A Blade With A Small Light Into The Patients Mouth , Oxygen Concentrator Brand- Philips/Bpl/Deck&Mount 1. Flow Rate :-0-5L/Min 2. Purity 93+3% 3. Outlet Pressure(Mpa):-0.04-0.07 4. Sound Level :-<50 Dba , High Flow Nasal O2 Cannula (Brand- Drager / Niceneotech ) High-Flow Nasal Oxygen (Hfno) Therapy Delivers Heated And Humidified Oxygen At High Flow Rates (Up To 60 Liters Per Minute) Through A Nasal Cannula , Electric Needle And Syringe Destroyer Hub Cutter Stainless Steel With Auto-Cut Protection , Clinical Thermometer(Digital) , Medical Labrotary Refrigrator ( Brand- Remi / Vav Intruments) Capacity 600 Litres Temperature Range 2°C To 8°C Internal Configuration Adjustable Shelves And Storage Bins For Optimal Space Utilization Cooling Type Uniform Cooling For Consistent Temperature Distribution Display & Controls Digital Display With User-Friendly Controls Power Supply Energy-Efficient Performance , Refrigrator Domestic Single Door Godrej/ Kelvinator/ Bluestar Capacity 200 Litres To 265 Liters Temperature Range 2°C To 8°C , Wieghing Scale Mannual , Knee Hammer , Sahli,S Heamoglobinometer , Artery Forcef Staright 6 (Brand - Jj Instrument) , Double Hook Retractor Standard Size (Brand - Jj Instrument) , B.P Handleno 3 (Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 4 Mosquito(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 6 Medium(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 8 Long(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 9 Long(Brand - Jj Instrument) , Allies Forceps Big (Brand - Jj Instrument) , Allies Forceps Medium (Brand - Jj Instrument) , Allies Forceps Small (Brand - Jj Instrument) , Mayo Scissior Str 5 ½ Sttilette Edge(Brand - Jj Instrument) , Mayo Scissiorcvd 6 ¼ Sttilette Edge(Brand - Jj Instrument) , Scissors Straight 6 Medium(Brand - Jj Instrument) , Scissors Straight 5 Small(Brand - Jj Instrument) , Scissors Straight 8 Big(Brand - Jj Instrument) , Steinman Pin Introducer Ss(Brand - Jj Instrument) , Towel Clip 6 Big(Brand - Jj Instrument) , Towel Clip 4 Small(Brand - Jj Instrument) , Wire Cutter 9 Standard Size(Brand - Jj Instrument) , Detnal Wire Standard(Brand - Jj Instrument) , Langenbeck Retractor Medium(Brand - Jj Instrument) , Langenbeck Retractor Small(Brand - Jj Instrument) , Langenbeck Retractor Big(Brand - Jj Instrument) , Cats Paw Retractor Standard Size(Brand - Jj Instrument) , K-Wire Cutter With Tungsten Carbide Tip 7 Standard(Brand - Jj Instrument) , Hintermann Distractor Medium(Brand - Jj Instrument) , Mippo Wire Passer For Long Bone Large(Brand - Jj Instrument) , Wire Bender Standard Size(Brand - Jj Instrument) , Kocher Clamp 8 Standard Size(Brand - Jj Instrument) , Glucometer (Brand-Dr Trust / Dr Morphen/Accucheck/Accurex) Fast Result In 5 Seconds Small 0.5Ul Blood Sample Size Large Memory. 10 Lancets Minimum Blood Sample: 0.5 Microlitre ; It Features A Large Display Screen That Can Store Up To 300 Test Results , Vortex Mixture (Brand -Remi /Borosil/ Benchmark) Type Of Product Cyclomixer Shaking Movement Orbital Orbital Diameter (Mm) 4 Motor Type Shaded-Pole Motor , Bio Saftey Cabinet Type-Ii A Microflow (Brand - Microflow / Thermofisher) Specification Material Of Construction (Main Body) Crca/Gi Powder Coated/Stainless Steel 304 Material Of Construction (Work Table) Stainless Steel 304 Dimensions External (Wxdxh) -1950 X 900 X 2250 Mm Internal (Wxdxh) - 1830 X 610 X 610 Mm Average Air Velocity - 90 ± 20% Fpm Hepa/Ulpa - Efficiency 99.997%/99.999% Class Level - Iso 3/5 (Class 100) Noise Level - 65 ± 5 Db Electrical - 230 V, 50 Hz, Single Phase Special Features - Motor Driven Front Door, Alarm, Hepa Filter Blockage, Timer For Uv Light, Power Socket Inside The Cabinet Pressure Sensor Monitoring, Digital Airflow Verification, Interior Eye Level Display, Display Parameters Including Down Flow Air Velocity, Total Operating Hours. Standards Us Fed Std 209 E, Iso 14644-1, Iest-Rp-Cc-002-2, Bsi Certifications- Ce & Iso , Co2 Incubator (Brand - Remi / Thermofisher) Specification Chamber Volume (150 Liters) Sensor Infrared Co2 Heating Method Air-Jacketed, Pid Control Co2 Range 0~20% V/V Co2 Control Resolution ± 0.1% (Ir Sensor) Temperature Range Rt+5~55°C Temperature Stability ± 0.1°C Humidity Method Natural Vaporization > 95% Co2 Recovery (Door Open 30S, Recovery To 5%) = 3 Min Temperature Recovery (Door Open 30S, Recovery To 37°C) = 8 Min Shelves 2 3 Interior Dimension (Mm) (W X D X H) 400 X 450 X 500 480 X 530 X 610 Exterior Dimension (Mm) (W X D X H) 590 X 687 X 790 670 X 767 X 880 Supply:220-240 Volts, 50 Hz Single Phase , Binocular Microscope - Olympus( Model Ch21i) / Magnus (Model- Pzb 22) (Specification) Optical System: - High Contrast Finite Colour Corrected Optical System Magnification:- 40X To 1000X Visual Magnification. Stand: Aluminium Die-Cast Stand With Hand Rests For Enhanced Comfort And Stability. Observation Head: - Sidentopf Binocular/Trinocular Head, 360° Rotatable, Interpupillary Distance 53-75Mm, With Dual Diopteric Adjustment. Eye-Piece: - Wide Field 10X F.O.V 22Mm, Anti-Fungal & Anti- Reflection Hard Coated (Optional 10X/18Mm). Nosepiece: - Reverse Angle Quadruple Nosepiece (Ball Bearing Type) With Precise Click Stops. Objective: - Qusp Series High-Contrast Flat Shield Plan Din Achromatic Objective 4X, 10X, 40X (S) And 100X Oil, (S), Anti-Fungal & Anti-Reflection Hard Coated. Mechanical Stage: - Rack-Less X Axis Double Plate Stage, Size 190 X 125Mm (+-5Mm) With Cross Travel 90 (X) X 50Mm (Y) On Ball Bearing With Co-Axial Controls. Hard Coated Surface For Scratch Resistance. Double Specimen Holder Clip. Focusing Control: - Co-Axial Coarse And Fine Focusing On Gear Systems For Smooth Operation. Fine Adjustment 0.2Mm/Rotation With Maximum 2-Micron Scale Increment. Condenser: - Sub-Stage Moveable Abbe Condenser, Centerable, Na 1.25 With Aspheric Lens. Iris Diaphragm And Special Frosted White Filter, Swing-In, And Swing-Out Filter Holder. Light Source: Led 3.5W 3V Illumination With Variable Illumination Control Universal Power Supply 110V-240V, Ce Approved. Supply With: Power Cable, Immersion Oil, Spare Bulb (In Led Only) User Manual, Vinyl Dust Cover, Cleaning Cloth, And 01 Units Fuses Optional Accessories: - Wooden Carrying Case, Pointers & Micrometre Reticules , Penta Head Microscope(Brand- Micron/Magnus/Weswox) Optical System- Infinite Optical System Viewing Head Inclination 30 Degree, Ipd: 48-75. 01 Piece Trinocular Head, Inclined At 30°, 360° Rotatable, Phototube With 100:0/50:50 Light Split With Sliding Prism. 04 Piece Compensation Free Binocular Head, Inclined At 30°, 360° Rotatable With Diopter Adjustment. Eyepiece-10 Pairs Of Wide Field Eyepiece Wf10x/22Mm Nosepiece- Inverse Quintuple Nosepiece. Objective Plan Achromatic Objective 4X Plan Achromatic Objective 10X Plan Achromatic Objective 20X Plan Achromatic Objective 40X Plan Achromatic Objective 100X Condenser - Swing Out Condenser N.A.0.9/1.25 Focusing-Coaxial Coarse And Fine Adjusting System With Tightness Adjustment And Upper Limited, Coarse Adjustment Range 30Mm. Fine Adjustment Precision: 0.002Mm Attachment- Multi Head Attachment And Support Stand. Stage- Ceramic Coated Double Layers Mechanical Stage Of 185X142 Mm With Capacity To Hold Two Slides At A Time With Slide Catcher On Left And Motion Control On Right Hand Side Illumination- External Illumination, Led 12V 100W Pointer - Multi Colored Ponters With Intensity Controllable Led Colored Indicator (Blue, Green And Red Led) Pointer 360 Rotatable, Brightness Adjustable, Arrow Control Sticks And Color Selection Dial. Video Adapter C Mount 0.5X Camera - 8Mp Hd Camera 4K Resolution With Removable Hd Card With Sd Card And Compatible Software. Display-43 Inch Hd Display Connected To Penta Head Camera For Live Display With Suitable Stabilizer For Display. Certifications - Ce(Notified), Ios 9001 (Iaf Accredited), Ios 13485 Warranty: 1 Year , All In One Pc ( Brand- Hp/Dell/Lenovo) All-In-One Pc 13Th Gen Intel Core I5 27 (68.6Cm) Fhd 16Gb Ram, 1Tb Ssd, Intel Uma Graphics, 710 White Wireless Keyboard And Mouse Combo (Windows 11 Home, Mso 21, Shell White, 6.72 Kg) 27-Cr0407in , Desktop ( Brand- Hp/Dell/Lenovo) 13Th Gen Intel Core I5 27 (68.6Cm) Fhd 16Gb Ram, 1Tb Ssd, Intel Uma Graphics, Wired Keyboard And Mouse Combo (Windows 11 Home, Mso 21) 27-Cr0407in , Air Conditioner( Brand- Hitachi/ Bluestar/ Daikin/ Carrier) Ac 1.5 Ton05star Smart Inverter Ac With Installation & Extra Wire /Pipe , Air Conditioner( Brand- Hitachi/ Bluestar/ Daikin/ Carrier) Ac 2 Ton05star Smart Inverter Ac With Installation & Extra Wire /Pipe , Lithium Battery 1500Wh Battery 48W 120Ah ( Brand- Luminous /Amaron) , Executive Premium Office Chair, Leather “Adjustable Arms Ergonomic Chair Must Behigh Back ( Brand- Godrej) , Office Table4x3 Feet( Brand- Godrej) , Mid Back Office Chiar ( Brand- Godrej) , Revolving Stool ( Brand - Aliza /Godrej) 3 Leg Ss Top Powder Coated Thicknessminimum- 14 Gauge , Steel Almirah W X H X D: 91.44 Mm X 197.866 Mm X 485.140 Feet For Office Use(Brand- Godrej) , Xerox Machine (Hp/Canon/Ricoh) Print Duplex, Copy, Scan, A3 Black And White Laserjet Printer, Enterprise Departments/ Distributed Workforce, Laser Printers Print Speed Is Up To 22 Pages Per Minute (Ppm) For Black And White Printing , Imcubator Electrical 23 Lts Thermostat , Centrifuge Machine Clinical ( Brand - Remi /Benchtop) , Salters Baby Wieghing Machine , Oto Scope , Chloroscope , Horrock,S Appratus Portable , Sound Level Meter Decible Meter With Lcd Display , Water Depth Sampler , Vaccine Carrier , Mosquito Catching Kit , Craft Water Testing Kit
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
22.
Heavy Industries and Public Enterprises #10390733 AOC
Vertical Extension & Other Development Works at Academic Block Annex-2 Palayad Campus, Kannur University, Kannur, Kerala under PM-USHA scheme- 1 Civil work -General Structural work 2 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge25 mm average thickness 3 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter 4 Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. 5 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar 6 Core Cutting of RCC slabs(12cm Maxi.thickness) by using mechanical core cutting equipment of required diameter of the pipe in full depth etc to the satisfaction of engineer in charge including all cost and conveyance materials and labours charge etc complete (dia 80-200mm) 7 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 8 Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work ( Payment shall be made on the cross sectional area of R.C.C. or R.B work) as per direction of Engineer-in-charge. 9 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within alead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia 10 Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock 11 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 12 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 13 Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) 14 Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. 15 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 16 Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum). 17 Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 18 Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 19 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 20 Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts 21 Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) 22 Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges 23 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. 24 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more 25 Block work & Finishing Work 26 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 27 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 28 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) 29 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 30 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) 31 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 32 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats 33 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 34 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work 35 Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections. 36 Teracotta Clay Jali work, For Building work, minimum 7.5 cm thick as per approved design and pattern of Engineer in charge in super structure above plinth level upto floor V level with cement mortar 1:4 (1 cement : 4 coarse sand) with neat finish, polishing work all complete. 37 Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with Zinc coating of 120 gms/ (both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wallwith suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre.The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channelof 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufactures specification and direction of engineer in charge all complete.75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG),plaster board conforming to IS : 2095 : (part 3) 1996 (Board with BIS Certification marks) 38 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 39 For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 40 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides 41 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness 42 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm 43 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in- charge. 44 Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm 45 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 46 Joinery 47 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 48 Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer- in-charge. 49 Providing and fixing factory made uPVC white colour casement/casement cum fixedglazedwindowscomprisingofuPVCmulti-chamberedframe,sashand mullion(whereeverrequired)extrudedprofilesduly reinforcedwith1.60+/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriatedimension,EPDMgasket,stainlesssteel(SS304grade)friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mmsizeforfixingframetofinishedwall,plasticpackers,plasticcapsand necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)Note: For uPVC frame, sash and mullion extruded profilesminus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm). 50 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness 51 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood 52 Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin - charge using Anjili/ Jack wood 53 Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc 54 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 55 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm 56 Providing and fixing CP Brass Handle 450mm in all types of doors with the necessary fittings and arrangements all complete. 57 Providingand fixing chromium plated brass handles with necessary screws etc. complete:200 mm 58 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality, with necessary screws etc complete as per direction of Engineer- in- charge. 59 French spirit polishing:Two or more coats on new works including a coat of wood filler 60 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6 mm for diagonal braces and central cross piece 61 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1800X2250 mm. 62 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1000X2200 mm. 63 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately) 64 Providing and fixing SS H handle having min 45 cm length in toughed glass door including all necessary screws etc. complete. 65 Providing and fixing of glass door SS Patch Lock with out handle in toughened glass door including all necessary screws etc. complete 66 Fixing 12 mm thick frameless toughened glass partition of approved brand and manufacture, including top & bottom fixing arrangement and making necessary holes etc. for fixing required fittings, all complete as per direction of Engineer-in- charge. 67 Providing and fixing 3M Fasara frosted etching film of thickness 25 microns self- adhesive of approved colour, shade, and quality with cutting as per approved design and pattern, including cleaning of glass and making surface smooth for fixing of film to the surface, all completed as per the direction of the engineer in charge. 68 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover 69 Providing and fixing ball bearing for rolling shutters. 70 Sanitary and CP Fittings 71 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 72 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 73 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 74 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap 75 Providing and fixing ceramic urinal partitions of standard size as per direction of Engineer-in Charge and of approved shade 76 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore 77 Providing and fixing uplasticised PVC connectionpipe with brass unions: 30 cm length15 mm nominal bore 78 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:150 mm diameter 79 Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore 80 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore 81 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm 82 Providing and fixing white vitreous china laboratory sink with C.I brackets, C.P. brass chain with rubber plug 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required:Size 600x450x200 mm 83 Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in- charge. 84 Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. 85 Flexible pipe32 mm dia 86 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with C.P. brass screws and washers complete. 87 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 88 Providing and fixing SS grating of approved quality and colour. Rectangular type with openable lid150 mm nominal size square 100 mm diameter of the inner hinged grating. 89 Providing and fixing disabled friendly bathroom kit with all accessories including wash closet with soft close seat cover and cistern with twin flush setting, wash basin of min dimensions 510mm x 400mm with all necessary fittings including Angle cock, Connection pipe, waste pipe, Spatula Lever basin mixer, Wall mounted 600mm long, Wall mounted grab bar 600 mm long and wall mounted hinged rail 750 x 750, Health Faucet with angle cock. Recommended Makes : CERA , Hindware, Jaguar or equivalent . 90 Plumbing 91 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall32 mm nominal outer dia pipes 92 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall40 mm nominal outer dia pipes 93 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall50 mm nominal outer dia pipes 94 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes 95 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes 96 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore 97 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore 98 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore 99 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore 100 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall 101 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall 102 Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall 103 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow 104 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee 105 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63x50 mm dia Reducer 106 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 107 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 6Kgf/cm2 108 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2 109 Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall 110 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend 111 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee 112 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl 113 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia End cap 114 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow 115 Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall 116 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend 117 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee 118 Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl 119 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap 120 Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow 121 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer 122 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore 123 Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 124 Yard Plumbing 125 Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2 126 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling 127 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):With common burnt clay F.P.S ( non modular) bricks of class designation 7.5 128 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Single pushfit Coupler110 mm 129 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionBend 87.50110 mm bend 130 Tile and Granite work 131 Providing and laying Matt Finished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 1200 x 600 mm. 132 Providing and laying Matt finished Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, ofapproved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 1200x600 mm 133 Providing and laying Anti Skid matt vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. 134 Providing and laying premium vitrified bathroom wall tile in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. 135 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm 136 Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining ( veneer work), backing filled with a grout of 12 mm thick average in cement mortar 1:3 ( 1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 ( 1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade ( To be secured to the backing by means of cramps, which shall be paid for separately).Area of slab over 0.50 sqm 137 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade. Area of slab over 0.50 sqm 138 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 139 Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work 140 Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 141 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 142 Providing and fixing 12 mm thick gang saw cut, mat /rough finished granite, machine cut for steps, ramps or inclined plate form with raking and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 143 Structural steel 144 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 145 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 146 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 147 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 148 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 149 False ceiling 150 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board 151 Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit. 152 Rainwater Harvesting ,Fire Tank,Septic Tank 153 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock 154 Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock 155 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 156 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 157 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level 158 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 159 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm 160 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm. 161 Supplying and fixing C.I with frame for manholes: 600mm x 600mm ( heavy duty) the weight of the cover and frame shall not be less than 208 kg 162 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 163 Providing and placing on terrace (at all floor levels) Stainless Steel 304as per IS 5522:1992 of capacity 5000 Litreswith suitable fixing arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 164 Providing and fixing of Fire Rated door 1200x2100mm- Hollow metal fire doors at all levels from ISO 9001-2015 certified Manufacturer. Fire door should be as per NFPA 80 and NFPA 252. All fire doors should be tested at UL for 120 minutes and should pass both UL10B and UL10C. Doors shall be made from pressed galvanized steel confirming to IS277 as per following specification.Frame:Door frame shall be single rebate grooved profile of size 125 x 55 mm made out of 1.6 mm (16 gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self-tabs. Frames to have in build grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate ANSI UL labeled hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff and the gaps shall be sealed with silicon sealant.Shutter: Door leaf shall be 46 mm thick fully flush double skin door without vision lite. Door leaf shall be manufactured from 1.2 mm (18 gauge) minimum thick galvanized steel sheet.The infill material shall be resin bonded honeycomb core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI standard. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf.Door and frames shall be finished Pure Polyester Powder coated and shall have passed minimum 500 hours of salt spray test.Vision glass: The glass shall be 5mm clear fire rated glass of equal rating and not exceeding size of 114 sq. inches.Door Hardware: Stainless steel Ball bearing Hinges 3 Nos, Minimum 90Kg hydraulic surface applied rack and pinion door closers, Mortice Sash Lock with cylinder. One Side Handle and Other Side with 2 point Panic Bar. 165 Road Work 166 Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30 167 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. 168 Water proofing 169 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 170 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) 171 Landscaping 172 Supplying of Flowering Shrubs (Heliconiya st. Vincent red, Ixora bush, Cana durf etc..) 173 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removalof unsaverieable material?s as per direction of officer in charge (including cast of plant & water )Cost of plantation per trees plants (for 100 nos.=427.45/100) 174 Providing and Laying Landscaping of outdoor area with buffalo grass and small plants with all necessary levelling and filling as required. 175 Signage 176 Providing and fixing in position the signage board made out of 3 mm opaque PVC foam board of computerised cut, PVC non reflective self adhesive vinyl painted foam board of required size and colour. 177 Providing and fixing non lit Signages made of CNC Cut Stainless Steel projected letters and fixing it at site with all necessary fitting arrangements and accessories as per the design and requirement on instructions of the engineer in charge. 178 Furniture 179 Two tiered reagent racks (MS with powder coating) with granite top of 150 mm depth for side workbenches. The two tier should be placed at a minimum spacing of 300 mm. The item should be in compliance with IS 4209 (2013), NABL etc. The Length should be customized as per lab workbench and vertical posts must be placed at appropriate spacing. 180 Supply and Installation of Sink Module with SinkEach sink module should have a minimum dimension of 900 mm (L) x 900 mm (W) x 900 mm (H) and made of MS as per IS 1730 shall be designed with a single cabinet (with 2 shutter, SS304 hinges for easy and noiseless opening and closing mechanism). This module should include a sink made of 5 mm thick polypropylene with black color body. Minimum Dimension of the sink: 450 mm (L) x 600 mm (W). Sink should include PVC tap connection-15mm diameter (Goose neck type), grating etc. The sink module shall be portable and provided with 18mm thick granite table top (with cut out for providing sink). Item to be inclusive of all necessary fitting arrangement.The item should be in compliance with IS 4209 (2013), NABL, WHO etc. 181 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 750 mm D 182 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 890mm D 183 Supply, Installation, Testing and Commissioning of Eye wash with Brass inject mould with epoxy powder coated body with auto released Valve and cup shaped water dispenser with min 1/2 HP power pressure booster pump 184 Counter Height Stools :Supply and erection of counter height stools ( bar stools ) of following specifications : Revolving adjustable Chrome plated steel body chairs with resistance to the corrosion. Cushion Seat with Lift mechanism for Adjustment of height. Minimum height 750mm before expansion. Medium Back rest and arm rest. Item shall be of reputed make. 185 Office Chair: Non-revolving executive chair with fixed armrest providing natural resting for arms. Seat with PU cutted foam backed fabric, back rest with mesh type fabric, Upholstery: Heavy duty rubber backed fabric in BLACK ( Size -55x60 cm) 186 Executive Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 187 Revolving Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 188 Cabinet/Wardrobe: Providing and fixing Cabinet/Wardrobe unit with 18 mm thick Multi wood board with one side decorative and other side balancing lamination. cupboard shutters edge to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickel plated bright finishing M.S. piano hinges conforming to IS:3818 marked with fixing chromium plated brass 50 mm cupboard or wardrobe knobs, special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. Depth of shelves to be 300-600mm and shelves to be fix with proper support and bracket holders. as per layout drawing approved by Engineer in charge. Make laminate: Greenlam/ Merino / Century. Only front elevation will be measured. 189 Supply and erection of Airport type 3 seater waiting chair with powder coated chromium finish having minimum dimensions 1675mm length X 710mm width X 775mm total height and 400mm seat height . Seat: High quality cold rolled 1.2mm thick steel perforated sheet pressed and welded to form the shape. Arm & Leg: High quality 1.2mm thick MS Tube / Sheet . Cross bar: High quality cold rolled 2mm thick steel sheet pressed and welded to form the shape. 190 Table of size Min 2300x600mm Made of minimum 18mm BWR ISI (303 Grade) plywood (Century, Greenply, Fineply or equivalent). On top and all sides with 1mm thick hot press (3M or Henkel) laminates (Brand MERINO, Associates or equivalent) of approved colour and pattern as per the design. The table is provided with 1 drawer, 1 Storage, 1 key board locks, handles, mini fix, dowels and screws. Exposed edges to be finished with 0.8 mm edge band as per specified colour. 191 Supply of wooden table with one drawer and Cupboard unit made of hard wood varnishing/painting all complete. Size: 1200x600x750mm 192 Providing & supply of Conference Table with executive chair of 13 Pax with the following specifications.Table top size :3600 x 1200mm. Table Tops –made of 25mm thick MDF with waterfall top edges finished in PVC Membrane using unique wrap around technology for better aesthetics & long lasting use. Under structure – Legs made of 25 mm thick standard Black matt colour post formed panels interconnected with 18mm thick standard Black matt colour pre-laminated modesty panels, with height adjustable levelers to take care of uneven floors. Wire Management & Concealed wire management to take care of basic wiring requirements both horizontally & vertically. For closed configurations, liftable top cover, made of 12mm MDF finished in PVC Membrane, is provided to access the horizontal wire carrier. Vertical wire management is through flexible vertical wire manager, popup grommet with power & RJ45 Socket. Designed for Flexibility through modular Construction, PVC Membrane Finish Tops for seamless surface, Post formed Legs for safe use, Provision for easy wire management, Upgradeable / reconfigurable for future needs. 13 Nos Revolving adjustable type Medium height Back Office Chair with arm rest with back tilt and swivel mechanism constructed out of mild steel and high quality plastic. 193 Supply of wooded Chairs with armrest of Hard Wood Plank Seat and Reaper Back. 194 Supply of Wooden Bench and Desk made up of Mahagani of minimum size - Bench Size :1 83x30X46cm Desk Size :183x41x75 cm 195 Supply and installation of steel podium made of SS304 with min dimensions 500mm X 450 mm X 1200mm and having a sloped top surface, and having a decorative/ plain front face all made of SS 304 as per the design and approvals of the architect/ Engineer - In - Charge 196 Wiring-General Electrical work 197 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 198 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 199 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire 200 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 201 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 202 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 6 Sq.mm + 1 x 6 sq.mm earth wire 203 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 204 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 205 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 16 sq. mm + 1 X 6 sq. mm earth wire 206 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 207 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 208 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 209 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm 210 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm 211 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm 212 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair 213 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 214 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 215 Fixtures 216 Supply and Fixing suitable size modular GI box with cover in front on and providing and fixing 1 no RJ 45 including connections as required. 217 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). 218 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 219 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet 220 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) 221 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet 222 Supply and Installation of surface/recess mounted LED 2x2 luminaire with CRCA housing suitable with fully diffused diffuser for general lighting. The luminaire should have CRI > 80 and CCT of both 6500K/5700K, Cool White Light. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3700 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 36 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro or equivalent 223 Supply, conveyance and Installation of compact, 2 feet,10-15W,LED tube light with high lumen giving soft glare free light including all required mounting accessories, frames complete. (Philips/WIPRO/Havells or equivalent) 224 Supply, Installation of surface mounted LED Tubelight. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 30 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 25k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make - Philips, Crompton, Wipro, Havells 225 Supply, Installation of surface/recess mounted LED Round/Square luminaire with CRCA housing suitable with fully diffused diffuser for general lighting in office areas. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 110 lumen/watt and Minimum system wattage of 10 -15 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro 226 Supply, conveyance and Installation of compact 10-15W LED Bulkhead Light giving soft glare free, Cool White light & complete with electronic driver including all required mounting accessories, frames, complete ( Make: Philips/WIPRO/Havells or equivalent) 227 Supply, Installation, Testing and Commissioning of 1400 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 228 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 229 Supplying, conveyance and Installation of 150-250 mm sweep,1350 rpm, 3 - 5 blade BLDC Exhaust Fan including frames and all mounting accessories complete.Recommended Make: Atomberg Efficio/Crompton Brisk Air 230 Supplying, conveyance and Installation of BLDC Type Wall Fan having 3 blade, 400 mm sweep, Speed 1350 rpm, Air Delivery 70 CMM minimum, Wall Mount Fan including frames and all mounting accessories complete. Recommended Make: Atomberg Renesa/V-Guard ENVIRO WF BLDC/Havells Platina 231 Supply, Installation, Testing and Commissioning of 450 mm sweep, 900 rpm heavy duty exhaust fan with louver in existing opening including making good the hole to suite the size of above fan complete with connections using 3 core 1.5sqmm multi core pvc sheathed copper conductor cable etc as required. 232 SITC of skirting light fitting with white LED 3 module along with suitable size modular metal box with inner and outer plates with all accessories. 233 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). 234 Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. lCD 235 Supply and installation of 2 Nos. 4 ft MS powder-coated hanging rods for tube lights, including supply and laying of 1.5 sqmm copper PVC insulated FRLS wire (3 runs: Phase, Neutral, Earth), necessary hardware (ceiling clamps, saddles, junction box, connectors), complete mounting, terminations, testing, and labour charges — complete in all respects. 236 Network and CCTV System 237 Supply of 16 ports Network Switch, Rack-mountable 10/100/1000 Mbps, Switching capacity 35.7 Mbps Features: Flow control, Layer 2 switching, auto-negotiation, auto- uplink (auto MDI/MDI-X), Weighted Round Robin (WRR) queuing, Quality of Service (QoS) Power: AC 120/230 V (50/60 Hz) complete. Make D-Link/TP Link/Cisco or equivalent 238 Supply Installation Testing and Commissioning of 32 channel embedded Linux NVR (Network Video Recorder), must connect 32 channel IP cameras, Should support min 2 SATA HDD and each should support Min 2TB and must record video simultaneously, (Recording Type: Continuous, Motion Detection, Alarm, Smart Event, Event Motion Detection, Alarm, Smart Event), Video Compression H.265(HEVC)/H.264+/H.264, 2 Year Warranty, Image quality should be maintained throughout the warranty period. Make: CP Plus/Hikivision/Dahua or equivalent 239 Network Switch for CCTV. 16 Port PoE Switch 1000BASE-T Copper Ethernet PoE+ connections, 10M/100M/1G RJ-45 copper ports, 1000BASE-X Fiber SFP ports, 16 port Auto sensing 10/100/1000 Mbps PoE, minimum CPU memory 512 MB with 2 SFP/combo ports, Energy Efficient Ethernet (IEEE 802.3az) Make: CP Plus/Netgear or equivalent 240 Supply, Conveyance and Installing of 2MP IP Dome/Bullet Camera having Progressive Scan True Day and Night Colour IR Camera having effective pixel of 2 MP, Video frame rate of 2MP @30FPS, Minimum illumination of 0.01 [email protected], 0 lux@IR On, 20 M IR Range, 24 IR LED, AWB, AGC, BLC, 2D Noise reduction, with 3.6mm board lense, 12 VDC, PoE IP67 rated weatherproof performance. 1 year warranty. Make: Bosch/CP Plus/Honeywell or equivalent 241 Supply and fixing of 6U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete 242 Supply Installation Testing & Commissioning of 16 Port Loaded Cat 6 - U/UTP Modular Toolless Patch Panel having a metal structure enabling them to be durably fixed to the uprights of the 19 chassis. Include rear cable manager to hold cables without need for cable ties. The termination of I/0s shall be without any manual crimping tools. 243 Supply and fixing of 4U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete. 244 Supply and connecting 2 meter long CAT6 cable Patch cord having RJ45 connectors crimped at both ends, to the existing outlets as required. Make: D-Link/TP-Link or equivalent 245 Supply and Installation of LED Color display of minimum 32 inch screen, complete, UHD display Make: LG/Samsung/Panasonic or equivalent. 246 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable 247 Supply, Installation and Integration of Dual Band WiFi Access Point on false ceiling along with accessories, having Fast Wireless Speed, simultaneous 2.4GHz 300Mbps and 5GHz, 867Mbps Dual Band connections for 1.2Gbps of total available bandwidth, Superior Coverage of Four Fixed External antennas provide stable wireless connections and optimal coverage, App Control, Interface of 1× 10/100 Mbps WAN Port and 4× 10/100 Mbps LAN Ports having Working Modes (Router Mode / Access Point Mode). Make: TP-Link/Netgear/DLink or equivalent 248 UPS 249 Supply, Installation, Testing and Commissioning of True on-line Double Conversion 10 KVA UPS system with 3:3 Crest Factor Three Phase Input Three Phase Output. Inversion shall be Microprocessor controlled with instantaneous sine wave Control using IGBT. UPS shall have standard display features, alarms, safeties, etc Input Voltage range : a) Phase – Three Phase with ground b)Voltage range 190 VAC – 470 VAC c)Input Frequency :50/60 Hz d)Power Factor : 0.95 or above e)THD : less than 5% with full load Bypass f) Voltage Range – 200VAC – 240 VAC ) Frequency range – 45-55 Hz/55-65 Hz Output Voltage Range h)Voltage Range – 200VAC – 240 VAC i)Frequency range – 50/60 Hz j)Voltage distortion – linear load <= 2% k)Voltage distortion – nonlinear load <= 5% l)Output waveform – pure sinewave m) Crest Factor – 3:1 Minimum Back up time : Continuous 30 Minutes at full load Rectifier shall be Full wave Type (Shall fully meet the specified input power requirements) Battery Type: Sealed Lead Acid Maintenance Free DC Voltage : 96V DC System, Battery Nos and capacity shall be designed for optimum storage space. Installation &Commissioning Required Breakers also needs to be provided in input and output side for the UPS. Make: Liebert Vertiv/APC by Schneider/Numeric by Legrand 250 Cable Trays 251 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.375 mm width X 50 mm depth X 2.0 mm thickness 252 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness 253 Fan Clamp 254 Providing and fixing 16 mm S.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 255 DB and Switchgear 256 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) 257 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 258 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 259 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door 260 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 261 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural 262 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole 263 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 264 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 265 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps 266 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 267 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 268 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts C curve TP MCB complete with connections, testing and commissioning etc. as required. 269 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 270 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral 271 Earthing and Lightning Arrestor 272 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re- filling etc. as required. 273 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 274 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. 275 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 276 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 277 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 278 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 279 Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. 280 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube,having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 281 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 282 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 283 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 284 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG) 285 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) 286 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG) 287 Street Lights 288 Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 289 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps 290 Water Purifier 291 Supply and Installation of Water Purifier having Multi-Stage Filtration: RO (Reverse Osmosis), UV (Ultraviolet), UF (Ultrafiltration), Storage Capacity: 7-9 Liters, Purification Features: RO: Removes dissolved impurities, heavy metals, and salts.UV: Kills bacteria, viruses, and other microorganisms. UF: Filters out fine particles and microorganisms. Mineral Booster: Adds essential minerals to enhance water taste.TDS Controller: Adjusts Total Dissolved Solids for taste preference. ActiveCopper: Infuses copper ions into the water for added health benefits.Aqua Taste Booster: Enhances the taste and maintains optimum pH level. In-Tank UV Disinfection: Keeps stored water pure.Smart Display/Indicators: Alerts for filter change, UV fail, water level, and service needs. Super Fine Sediment Filter: Removes fine and coarse particulate impurities. Water Level Indicator: Monitors the purified water level in the storage tank. Make: Aquaguard Aura 7L/ Bluestar Aristo 7L/Kent Grand Plus ZWW 9-Litre/ LG 8L 292 LT Cabling and Termination 293 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 294 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 295 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp 296 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 297 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp 298 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm 299 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm) 300 Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 400 sq mm 301 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm) 302 LT Panels 303 Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work. General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall befl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 400A 3kA 4 Pole MCCB - 1no Ics = 100% Icu rating Digital Voltmeter 0- 500V with selector switch & Digital ammeter (0-400A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 400A. Out going : 250A ,50kA 4 Pole MCCB - 2no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 304 Lift panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 40A ,16-25kA TP MCB - 6 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list.Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 305 Sub Panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required. Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch &Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 32A ,16-25kA 4 Pole MCCB - 4 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 306 SSB2- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 250A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-250A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 250A. Out going : 1) 63A ,16-25kA 4 Pole MCCB - 8 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 307 Transformer 308 Supply , Installation, Testing and commissioning of 500 kVA outdoor unitized substation with an 11kV/433V dry-type cast resin transformer and a 630A VCB typically includes a compact prefabricated design conforming to IEC62271-202 standards, offering IP53/IP23 protection, and featuring compartmentalized construction to prevent accidental entry into energized areas. The substation is designed to withstand electrical impulses, thermal, and dynamic stresses, ensuring reliable and robust performance with low power loss and noise levels. The installation involves placing the substation on a prepared concrete plinth, connecting high-tension (HT) and low-tension (LT) cables, and ensuring proper earthing and safety measures. The commissioning process includes testing the transformer, switchgear, and protection systems to verify operational integrity. Make: Unipower/Intrans/Voltamp 309 MSB and APFC Panel 310 Supplying, installation, testing & commissioning of cubical type MAIN SWITCH BOARD suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having front surface area 6 sq.mtr (Approx.) fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 630 Amp capacity extensible type TPN aluminium alloy bus bars of height conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :- Interlocking:Electrical through advance contacts in MCCB/ ACB’s (incomers & bus couplers) and mechanical (castel key) interlocking should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possibility of accidentally approaching two supplies at one bus section.Interlocking b(I) Incoming : 2 Nos 800 Amps (DG and MAINS) each four pole ACB of fault breaking capacity 50 KA (Ics=Icu upto 433 V manually operated, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS 1397- 2 : 1993 as amended up-to-date complete with following accessories for each MCCB(a) Independent manual spring closing mechanism- 1 No.(b) Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection- 1 set.(c) Digital* type Voltmeter (0-500 V), with selector switch & back up HRC fuses/MCBs-1 set. (d) Digital* type Ammeter (0-.600 Amp), with selector switch and one set of 3 nos. CT’s of ratio. 800/5A Class I accuracy and 15 VA burden- 1set. (Ratio to be fi lled up).(e) 3 Nos. Phase indication LED lamps with 2 Amp back up HRC fuse, breaker ‘ON’ indicating light with 2 A HRC fuse, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.(f) Shunt trip coil 220 V A.C. (II) Bus Bars :TPN aluminium bus bars of minimum of 800 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec (II) Outgoing :(1) (a) 4 Nos. 250 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 250/5 Amps Nos. (c) Digital* type ammeter (0- 400 Ap) with selector switch set. (2) (a) 1 Nos. 200 Amp4 Pole MCCB for (Ics = 35 kA upto 433 V) (b) CT’s of ratio 200/5 Amps set (c) Digital* type ammeter (0- 250 Amp) with selector switch set. (3) 3 Nos 160 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 160/5 Amps set (c) Digital* type ammeter (0- 200 Amp) with selector switch set. The switchgears/measuring instruments shall be as per the Choice of the Engineer in charge. The panel shall be mounted on required structural steel supports and frames for mounting, the price quoted shall be inclusive of the same. The panel shall have suitable provision for connecting to the incoming cables of 3R x 400 sqmm XLPE Aluminium cables and shall be provided with necessary earth leakage relays as per the Inspectorate Norms. The panel shall be as per the IS standards and shall conform to all norms of EB/Inspectorate/CEA. Make of Switchgear : ABB/L & T/Schneider Electric/Siemens/Legrand 311 Design, Manufacture, Supply, Installation, Testing and Commissioning of Automatic Power correction Panel having Incomer: 250A, TPN MCCB, Digital Multifunction meter for V,A,F,PF With CTs CL:1 with RYB Indication lamps-1 Set 250A Aluminium bus bar with heat shrinkable insulation sleeves-1 set, Intelligent power factor controller with control MCBs etc. complete The panel shall comprise of suitable combination of capacitor banks upto a total of 100 kVAR and shall be designed as per the standards of Electrical Inspectorate/CEA. 312 DG and AMF Panel 313 Supply, Installing, Testing and Commissioning of & Silent Type& Diesel Generating set having CPCB IV+ acoustic enclosure having Prime Power Rating of 500 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor and consisting of the followings: Diesel engine radiator cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories. Engine mounted Instrument Panel fitted with and having digital display and necessary indication coupled to Synchronous alternator rated at 500 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor. Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. Daily service fuel tank of 440-460 litres capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. Dry exhaust manifold with hospital exhaust silencer and catalytic convertor. 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (lead acid type) as required as per specifications. Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications. 314 Design, Fabricating, Supply, Installing, Testing & Commissioning of automatic mains failure control including auto by-pass panel, suitable for 500 KVA silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH & provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required, all complete and inter locking including the following: (a) 1 Nos. 630 Amp., 50 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50-100% having adjustable OL & SC. Set at 350A (b) Auto/Manual/Test/Off selector switch (c) 2 Nos. over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay. (d) 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering(e) Energy analyser unit to indicate current voltage frequency power factor and KWH(f) Indicating lamps for load on mains and load on set(g) Fuse for instruments(h) Battery charger, complete with transformer/ rectifi er, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.(i) Main supply failure monitor(j) Supply failure timer(k) Restoration timer(l) Control unit with three impulse automatic engine start/stop and failure to start lockout.(m) Impulse counter with locking and reset facility.(n) ON/OFF/Control circuit switch with indicator(o) Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning. AMF Panel shall be connected to Main Switch Board incomer with necessary interlocking arrangement to prevent simultaneous switching on of power supplies. All integration between Main Switchboard and AMF Panel is under contractor scope. 315 HT Cable 316 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium powercable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 300 sq mm 317 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm 318 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm 319 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm 320 Air Conditioning Works 321 Supply, Installation, testing and commissioning of 3 x 3 Cassette type Air Conditioner of following capacity and specifications: Consisting of ceiling-mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of energy-efficient suitable rotary compressor for operation on single-phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation, with R-32/R-410A or equivalent refrigerant and fixing of room (fan coil) unit on ceiling, standard 5 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1 dia drain PVC pipe with insulation up to 5 m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. (Make: Voltas, Blue Star, Daikin, Hitachi, Carrier or equivalent). Minimum 2 TR 3 Star rated (inverter type AC) as per BEE 322 Supplying additional copper piping of required size and connecting the same to the available piping and extension of the same through 100mm PVC duct inside false ceiling. 323 Electrical Dismantling Works 324 Dismantling of existing outdoor transformer and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 325 Dismantling of existing DG set 100 kVA, AMF panel etc and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 326 Electrical Works- Fire 327 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm 328 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 329 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 330 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 331 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) 332 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) 333 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm) 334 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 335 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 336 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 337 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 338 First Aid Hose reel &Wet Riser system 339 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.a.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585b.20 mm nominal internal dia gun metal globe valve & nozzle. c.Drum and brackets for fixing the equipmets on wall.d.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m 340 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 341 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way-100 mm dia M.S. Pipe 342 Supply and fixing of Air release valve SS body of 25 mm dia (UL Listed). 343 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 344 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 345 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) 346 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304) 347 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel 348 Hose Box - Supply, Installation, Testing and Commissioning of Hose Box -Double door - (cabinet) to accommodate Two pieces of 63 mm dia fire hose along with one pair of 63 mm dia male & female couplings and one branch pipe. The cabinet is made of MS sheet, painted in approved red colour with glass fronted hinged doors and lock &key (UL Listed). 349 Supply and Installation of Fire Brigade Draw-out Collecting head of CI Body having gunmetal 63mm dia instantaneous male draw out confirming to IS:903 suitable to fit on 100mm dia pipe with necessary flanges, rubber gasket, nut & bolts and other items. 350 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 351 Fire extinguishers 352 Supply &installation of ISI ABC type fire extinguisher of 4 kgs. Make SAFEX/ MINIMAX / CEASEFIRE or equivalent(UL Listed) 353 Supply &installation of CO2 type fire extinguisher of 4.5 kgs. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 354 Supply & installation of water mist type fire extinguisher of 9 liters. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 355 Supplying & Installing of Clean agent based automatic modular fire extinguisher (ceiling mounted) suitable for A,B,C class fires & electrical fires, Capacity- 5Kg 356 Supplying & Installing of Mechanical Foam (Stored Pressure) Type fire extinguisher of 9L capacity with mounting clamp. ISI approved. Make : SAFEX/MINIMAX/CEASEFIRE or equivalent 357 Fire Pumps & Fire Panel 358 Electric driven Main Fire Pump: Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.1620 lpm at 56 m Head 359 Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads. 1620 lpm at 56 m Head 360 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)a.Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325.c. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. As required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 56 m Head 361 Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector switch & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING (Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.Jockey Pump63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROLControl for diesel engine comprising - Automatic/Manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller.Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification 362 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 150mm 363 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 80mm 364 Supply and Installation of 12V DC, 200Ah maintenace free battery suitable for Diesel Engine driven fire pump operation with required connect cable set, battery stand. 365 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 100mm 366 Signages 367 Supply and fixing in position Exit Signages photo luminescent type with indication arrows and letters Exit/Fire Exit/ Staircase/FIRE/Fire Station/Fire Fighting Equipment/Fire Duct/ Fire Extinguisher/ Floor/Fire Command Centre/Fire Pump Room/ No Smoking / Danger/ Call point / Sounder Identification Numbers (Ground/ 1st/2nd)/ In case of the fire do not use lift, use stairs and other mandatory signages recommended by Fire Departments having dimension 30 cm x 15 cm complete inculding fixing mechanism. 368 Supplying and Installing in position the signages approved by Kerala state fire service - of minimum size 1ft x 1.5ft made out of PVC rigid sheet 3mm thick with computer cut PVC non- reflective self adhesive imported vinyl painted on the front of PVC rigid sheet complete with wall mounting arrangements with mirror screws. with lettering- ASSEMBLY AREA 369 Signboards: Supply and Installation of Fire Escape Plan with fire fighting equipment location, exit in A3 Foam sheet with plastic lamination with necessory accessories to fix it on wall. 370 Supply and fixing in position & Fire Order& signage in suitable size made of high quality PVC foam sheet with photo luminescent lamination to make it glow automatically in the dark, with suitable arrangement to fix it on wall. 371 Supplying & fixing in position Assembly Point sigange in suitable size on aluminium composite panel with suitable stand to fix it on open area outside building. Assembly Point 372 Terrace pump 373 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)a.Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325.c. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head 374 Design, Supply, Installation, Testing, and Commissioning of an Automatic Terrace Fire Pump Panel, including:- IP54-rated enclosure with powder-coated CRCA sheet steel.- 32A 16kA MCCB, 15 HP-rated pump 3P contactor, overload relay, and pressure switch for automatic pump operation.- Auto/Manual selector switch, START/STOP push buttons, hooter, timer, and protection features (dry-run, phase failure, etc.).- Indicators (Power ON, Pump Running, Fault, Low Pressure), meters (Voltmeter, Ammeter with selector switches).- Copper wiring, termination, and provision for cable glands.- Installation, onsite calibration, and full functional testing for pressure-based automation. 375 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 376 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 377 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 378 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 379 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100mm dia 380 Pressure Guage-Supply, Installation, Testing and Commissioning of pressure guage, 4 & dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 381 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations (UL Listed).20 mm dia Make : Kartar/ Atom 382 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 383 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 384 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 385 Above Ground Piping 386 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia 387 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia 388 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia 389 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :250 mm dia (wall thickness 6.3 mm) 390 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150 mm dia 391 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :200 mm dia (wall thickness 6.3 mm) 392 Supply and Installation of 80mm dia M.S. &C& Class Diesel Engine exhaust pipe duly insulated with 50mm thick Glass wool with 1mm thick aluminium sheet cladding with bellows, flexible joint, necessary support, making hole in brick wall for pipe installation.Pipe dia 80mm 393 Underground piping 394 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 150 mm. Make - TATA / JINDAL 395 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 200 mm. Make - TATA / JINDAL 396 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (1m below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 100 mm. Make - TATA / JINDAL 397 Valves, measuring devices & switches 398 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required:200mm dia 399 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required80 mm dia 400 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 401 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required150 mm dia 402 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80mm dia 403 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150mm dia 404 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.150mm dia 405 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. 406 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 407 Pressure Gauge-Supply, Installation, Testing and Commissioning of pressure gauge, 4 dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 408 Supply and fixing of Air release valve Brass body of 25 mm dia (UL Listed) following IS standards, with required pressure rated. 409 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 410 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 411 MOEFA system, Automatic Detection & Fire Alarm System 412 Supplying, installing, testing and commissioning approved make Microprocessor based Multi-loop, Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 trouble events including1000 alarm log history events, Self Programmable alphanumeric keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 Loops. Each loop shall have a capacity of minimum 125 detectors & 125 other devices exculding 20% spare. The panel shall work in degrade mode in case of CPU failure, Products not having this feature may offer Redundant CPU. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition with the charging capacity of 200AH. The panel shall be capable of self programing without any dependancy on dongle or programming software. Quoted rate shall include supply of necessary software & hardware for progamming the panel with all necessary licence. Panel shall have Modbus over IP protocol for future integration with BMS. However, for present arrangement FA system will be standalone with 24x7 monitoring. The panel shall be capable of connecting to the cloud platform/solution. Complied to meet UL864, 10th Edition 6 Loop Networkable Addressable Fire Alarm Control Panel(Make: Honeywell or Equivalent) 413 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 414 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 415 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 416 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. 417 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 418 Supplying, Installation, testing & commissioning of external power supply unit provides regulated and filtered 24 VDC power for hooter operation.Battery backup with built in charging. 419 CABLING & WIRING Supplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 420 Miscellaneous 421 Preparation of initial and final drawings, submission to Panchayath, Municipality, KSEB, Electrical Inspectorate, Kerala Water Authority, State Pollution Control board, Fire Department, Factories and Boilers and other agencies if any for getting approval, sanction and No Objection Certificate for building permit and completion from Fire Department and other department. Quoted rate shall be excluding statutory fee (All statutory fees shall be borne by Client-actual statutory fees shall be reimbursed on submission of original bill/challans from authorities).
Contract Date: Jul 17, 2025 Contract Value : 11.48 Crore
Boards / Undertakings / PSU No of Bidders 1
23.
Health and Family Welfare #10357309 Price Bid
Tender For Who-Gmp Certified Medicine And Isi/Iso/Ce Certified Material, Pathological Items And Equipments , Name Of Items , Tab 5-Fluro Uracil500 Mg , Tab Abacavir 300 Mg , Tab Aceclofenac + Paracetamol + Serrapeptidase 100 + 325 +10Mg , Tab Aceclofenec 100Mg , Tab Acetazolamide 250 Mg , Tab Acetylsalicylic Acid (Aspirin) 25 Mg , Tab Acetylsalicylic Acid 150 Mg , Tab Acyclovir 200 Mg , Tab Acyclovir 800 Mg , Tab Albendazole 400 Mg , Tab Allopurinol300 Mg , Tab Allopurinol 100 Mg , Tab Alprazolam 0.25 Mg , Tab Amiodarone 100 Mg , Tab Amlodipine + Atenolol , Tab Amlodipine 10 Mg , Tab Amlodipine 5 Mg , Tab Amoxycillin+Clavulanic Acid (Amoxycillin 500 + Clavulanic Acid 125Mg) , Tab Artemether (A) + Lumefantrine (B) 20 Mg (A) + 120 Mg (B)1X6 , Tab Artemether (A) + Lumefantrine (B) 80 Mg (A) + 480 Mg (B) , Tab Artemether (A) + Lumefantrine (B)Oral Liquid 80 Mg (A) + 480 Mg (B)/5 M , Tab Ascorbic Acid (Vitamin C)100 Mg 100 Mg , Tab Aspirin 75 Mg , Tab Atenolol 50 Mg , Tab Atenolol100 Mg , Tab Atorvastatin 10 Mg , Tab Atorvastatin 40 Mg , Tab Azithromycin 250 Mg , Tab Azithromycin 500 Mg , Tab Baclofenbaclofen 40 Mg , Tab Betahistine 8 Mg , Tab Betamethasone 0.5 Mg , Tab Bicalutamide 50 Mg , Tab Bisacodyl 5Mg , Tab Bisacodylsuppositories 5 Mg , Tab Calcium Carbonate . 500 Mg , Tab Calcium Leucovorin50mg , Tab Calcium With Vitamin D3calcium Equivalent To 500 Mg & Vit. D3 250 Iu , Tab Capeciine500 Mg , Tab Carbamazepine 200 Mg , Tab Carbamazepine 200 Mg , Tab Carbimazole 10 Mg10strip , Tab Carboplatin450 Mg , Tab Cefixime 200 Mg , Tab Cefixime 50 Mg , Tab Cefpodoxime + Clavunate 200+125Mg , Tab Cefpodoxime- 200 Mg , Tab Cetirizine 10 Mg , Tab Cefadroxil 250 Mg , Tab Cefadroxil 500 Mg , Tab. Cefuroxime( 250 Mg) , Tab. Cefuroxime( 500 Mg) , Tab. Cefuroxime 500Mg + Clavunate 125Mg , Tab Chloroquine 250 Mg , Tab Chlorpromazine 100 Mg , Tab Chlorthalidone12.5Mg , Tab Chlorthalidone25mg , Tab Cinnarizine 25 Mg , Tab Ciprofloxacin 250 Mg , Tab Ciprofloxacin 500 Mg , Tab Ciprofloxacin + Tinidazole(250 Mg + 300 Mg) , Tab Ciprofloxacin+ Tinidazole (500Mg & 500Mg) , Tab Ciprofloxacin + Tinidazole(500Mg+600Mg) , Tab Cisplatin50 Mg , Tab Clarithromycin 250 Mg , Tab Clarithromycin 500 Mg , Tab Clofazimine 100 Mg , Tab Clofazimine 50 Mg 4 , Tab Clomiphene Citrate50 Mg , Tab Clonazepam 0.5 Mg , Tab Clopidogrel 75 Mg , Tab Clotrimazole (Vaginal )Pessary 500 Mg (With Applicator)Single , Tab Clozapine 25 Mg , Tab Clozapine 50 Mg , Tab Cyclophosphamide500 Mg , Tab Dapsone 100 Mg , Tab Deferasirox 250Mg , Tab Deferasirox 500 Mg30 , Tab Deferiprone500mg , Tab Deriphylline Sr 300 Mg , Tab Dexamethasone 0.5 Mg , Tab Diazepam 5 Mg , Tab Diclofenac 50 Mg , Tab Diclofenac 100Mg(Sr Tablet) , Tab Diclofenac 50Mg +Paracetamol 325Mg+Chlorzoxazone 500Mg , Tab Diclofenac 50Mg + Paracetamol 500Mg + Chlorzoxazone 250Mg(50Mg+500Mg+250Mg) , Tab Diclofenac Sodium + Paracetamol +Serratiopeptidase(50 Mg +325 Mg + 10 Mg) , Tab Dicyclomine 500 Mg , Tab Dicyclomine Hydrochloride 20 Mg , Tab Diethylcarbamazine 100 Mg , Tab Digoxin 0.25 Mg , Tab Digoxin 250 Mg , Tab Diloxanide Furoate 500 Mg , Tab Diltiazem 60 Mgl , Tab Diltiazemsr90 Mg , Tab Diltizem 30 Mg , Tab Diphenylhydantoin 30 Mg , Tab Dispersablehydroxyurea100 Mg , Tab Disulfiram 250 Mg , Tab Docetaxel120 Mg , Tab Domperidone 10 Mg , Tab Donepezil 5 Mg , Tab Doxorubicin50 Mg , Tab Drotaverine 40 Mg , Tab Empagliflozin25 Mg , Tab Enalapril Maleate 10 Mg , Tab Epirubicin100 Mg , Tab Erlotinib 150 Mg , Tab Escitalopram 10 Mg , Tab Ethamsylate250 Mg , Tab Ethinylestradiol (A) + Levonorgestrel (B) 0.03 Mg (A) + 0.15 Mg (B) , Tab Ethinylestradiol 0.01 Mg , Tab Ethinylestradiol 0.05 Mg , Tab Etophylline+Theophylline 100 Mg (Etophylline 77+Theophylline 23 )Mg , Tab Etoposide100 Mg , Tab Exemestine 25 Mg , Tab Ferric Carboxymaltose250mg , Tab Ferrous Ascorbate(100Mg. Elemental Iron+Folic Acid 1.5 Mg) , Tab Finofibrate160 Mg , Tab Finofibrate 40 Mg , Tab Fluconazole 150 Mg , Tab Flunarizine 5 Mg , Tab Fluoxetinecapsule 20Mg , Tab Folic Acid 5Mg , Tab Furazolidone 100 Mg , Tab Furusemide 40 Mg , Tab Gefitnib 250 Mg , Tab Gemciine1.4 Mg , Tab Glibenclamide 5 Mg , Tab Gliclazide 80 Mg , Tab Glimeperide 1 Mg , Tab Glimeperide 2 Mg , Tab Gutta Percha (Gp)30/Bottel , Tab Haloperidol 5 Mg , Tab Hydrochlorothiazid 12.5 Mg , Tab Hydrochlorothiazid 50 Mg , Tab Hydrochlorothiazide 25 Mg , Tab Hydroxychloroquine 200 Mg , Tab Hydroxyzine25 Mg , Tab Ibuprofen 400Mg , Tab Imatinib Mesylate400 Mg , Tab Imipramine 25 Mg , Tab Iron & Folic Acid Sugar Coatediron And Folic Acid Sugar Coateddried Ferrous Sulphate Ip Eq. To 45 Mg Ferrous Iron And 400 Mcg Folic Acid Ip (Pink Colored ) - , Tab Iron & Folic Acid Sugar Coatediron Folic Acid Sugar Coated (Blue ) Ferrous Sulphate Ip Equivalent To60 Mg Elemental Iron & 500 Mcg Folic Acid Ip , Tab Iron & Folic Acid Sugar Coatediron Folic Acid Sugar Coated (Red ) Ferrous Sulphate Ip Equivalent To60 Mg Elemental Iron & 500 Mcg Folic Acid Ip , Tab Isosorbide -5-Mononitrate 20 Mg , Tab Isosorbide Dinitrate 5 Mg , Tab Itraconazole/Capsule 100 Mg , Tab Ivermectin 12 Mg , Tab Ketorolac10 Mg , Tab Labetalol 100 Mg , Tab Lenalidomide 25 Mg , Tab Letrozole 2.5Mg , Tab Levetiracetam 250 Mg , Tab Levodopa (A) + Carbidopa (B) 100 Mg (A) + 10 Mg (B) Cr , Tab Levodopa (A) + Carbidopa (B) 100 Mg (A) + 25 Mg (B) Cr , Tab Levodopa (A) + Carbidopa (B) 250 Mg (A) + 25 Mg (B) , Tab Levofloxacin 250 Mg , Tab Levofloxacin 500 Mg , Tab Levonorgestrel 0.75 Mg , Tab Levocetirizine Tab 5Mg , Tab Levocetirizine + Monteleukast(5 Mg + 10 Mg) , Tab Levocetrizine 10 Mg, Montelucost 20 Mg , Tab Levocetrizine Hcl 5Mg + Ambroxol Hcl 75 Mg , Tab Levothyroxine 100 Mcg100per Bottle , Tab Levothyroxine 50 Mcg100per Bottle , Tab Linezolid 600 Mg , Tab Lithium Carbonate 300 Mg , Tab Loperamide 2 Mg , Tab Lorazepam 1 Mg , Tab Losartan10 Mg , Tab Mebeverine 200 Mg10 X 15 , Tab Medroxy- Progesterone 10 Mg , Tab Mefenamic Acid 250Mg + Drotaverine 80Mg , Tab Metformin + Gliclazide 500+80Mg , Tab Metformin 500 Mg , Tab Metformin-Sr1000mg10x15 , Tab Methotraxate50 Mg , Tab Methyl Ergometrine Maleate 0.125 Mg , Tab Methyldopa 250 Mg , Tab Methylprednisolone 16 Mg , Tab Methylprednisolone 4 Mg , Tab Metoclopramide 10 Mg , Tab Metoprololsr25 Mg , Tab Metoprololsr/Plain50 Mg , Tab Metronidazole 400 Mg , Tab Mifepristone 200 Mg1 Per Pack , Tab Misoprostal 100Mcg , Tab Misoprostal 200 Mcg4in 1 Pack , Tab Misoprostol 200Mcg (Oral/ Vaginal) , Tab Montelukast 5 Mg , Tab Morphine 10 Mg , Tab Morphine+I469sr/30 Mg , Tab Multivitamin Sugar Coated Nfi Formula Sugar Coated Vit A 2500 Iu , Vit C 50Mg, Calcium Pantothenate- 1Mg,Vit B1 2 Mg Vit B6 0.5 Mg Vit D3 200 Iu Vit , Tab Nicotinamide 50 Mg7 , Tab Nifedipine 10 Mg , Tab Nitroglycerine (Glyceryl Tri Nitrate)Sub-Lingual0.5 Mg10 , Tab Norfloxacin 400 Mg , Tab Norfloxacindispersible100mg , Tab Ofloxacin200 Mg , Tab Ofloxacin400mg , Tab Ofloxacin + Ornidazole(200Mg And 500Mg , Tab Ofloxacin 200Mg +Tinidazole 600Mg(Tab) , Tab Olanzapine 5 Mg , Tab Olanzapine10 Mg , Tab Ondansetron 4 Mg , Tab Ormeloxifene 30 Mg , Tab Oxaliplatin100 Mg , Tab Paclitaxel260 Mg , Tab Paracetamol 500Mg , Tab Paracetamol 650Mg , Tab Penicillin V (Phenoxymethyl Penicillin)250 Mg , Tab Phenobarbitone 30 Mg , Tab Phenobarbitone 60Mg , Tab Phenytoin/ Diphenylhydantoin 100Mg , Tab Povidone Iodinevaginal Pessary 200Mg10 X 10 , Tab Prednisolone 10Mg , Tab Prednisolone 20 Mg , Tab Prednisolone 20Mg , Tab Prednisolone 30Mg , Tab Prednisolone 40Mg , Tab Pregabalin 150 Mg , Tab Primaquine 15 Mg , Tab Primaquine 2.5 Mg , Tab Primaquine 7.5 Mg , Tab Propranolol 10 Mg , Tab Pyridoxine 10 Mg , Tab Pyridoxine 100 Mg , Tab Pyridoxine 40 Mg , Tab Quinine 300 Mg , Tab Rabeprazole 20 Mg , Tab Ramipril 2.5 Mg , Tab Ranitidine 150 Mg , Tab Riboflavin 5 Mg7 , Tab Risperidone 2 Mg , Tab Salbutamol 4 Mg , Tab Sitagliptin 50 Mg , Tab Sodium Valproate 500 Mg , Tab Sorafenib 200Mg , Tab Spironolactone 25 Mg , Tab Sucralfate 20 Mg , Tab Sulfamethoxazole And Trimethoprim800mg +160Mg , Tab Sulfamethoxazole+ Trimethoprim (Pediatric S) 400 Mg+80 Mg , Tab Sulfamethoxazole+Trimethoprim200mg +40 Mg , Tab Sulfasalazine 500 Mg , Tab Sumatriptan 25 Mg , Tab Sunitinib/Capsule50 Mg , Tab Sitagliptin 50 Mg +Metformine500mgs , Tab. Deferiprone 500Iu , Tab Tamoxifen 10 Mg3 , Tab Tamoxifen20 Mg , Tab Tapentadol 100 Mg , Tab Telmisartan 40 Mg , Tab Temozolamide 250 Mg , Tab Thiamine 100 Mg7 , Tab Thinylestradiol (A) + Levonorgestrel (B) 0.03 Mg (A) + 0.15 Mg (B) With Ferrous , Tab Tinidazole 300 Mg , Tab Tramadol 50Mg , Tab Tranexamic Acid 500Mg , Tab Trihexyphenidyl 2 Mg , Tropicacyl Plus Eye Drop , Tab Verapamil 40 Mg , Tab Vincristin1 Mg , Tab Vitamin. B Complex Nfi (Prophylactic) B1 2 Mg, B2 2Mg, B6 0.5 Mg, Niacinamide 25 Mg, Calcium Pantothenate 1 Mg , Tab Warfarin 1 Mg , Tab Warfarin 2 Mg , Tab Warfarin 5 Mg , Tab Zinc Sulphate Dispersible 10Mg , Tab Zinc Sulphate Dispersible 20Mg10 X 10 , Tab Zoledronic Acid4 Mg , Tab Zolpidem10 Mg , Cap Amoxycillin 250 Mg10 X 10 , Cap Amoxycillin 500 Mg10 X 10 , Cap Ampicillin 250 Mg10 X 10 , Cap Ampicillin 500 Mg10 X 10 , Cap Cephalexin 250 Mg10 X 10 , Cap Cephalexin 500 Mg10 X 10 , Cap Clindamycin 150 Mg10 X 10 , Cap Cloxacillin 125 Mg10 X 10 , Cap Cloxacillin 500 Mg10 X 10 , Cap Cycloserine 125 Mg10 X 10 , Cap Doxycycline 100Mg10x10 , Cap Hydroxyurea 500 Mg , Cap Nifedipine 5 Mg10 X 10 , Cap Pomalidomide 2 Mg , Cap Rifampicin 150Mg , Cap Rifampicin 300Mg , Cap Rifampicin 450Mg , Cap Rifampicin 600Mg , Inj Acyclovirinj 250 Mg/Vialvial , Inj Adenosineinj 3 Mg/ Ml -2 Ml Amp , Inj Adrenalineinj 1 Mg/ Ml1 Ml Amp , Inj Amikacininj 100 Mg/2 Ml2 Ml Vial , Inj Amikacininj 500 Mg/2 Ml Vial2 Ml Vial , Inj Aminophylline Inj 25 Mg/ Ml10 Ml Vial , Inj Amiodaroneinj 50 Mg/ Ml3 Ml Amp , Inj Amoxycillin+Clavulanic Acid (Amoxycillin 500 + Clavulanic Acid 100 Mg)/ , Inj Amphotericin B 50 Mgvial/Ampoules , Inj Ampicillininj 500 Mg/Vialvial , Inj Anti D Immunoglobulin For Iv/Im Use (Monoclonal)Inj 150Mcg1 Ml Vial , Inj Anti D Immunoglobulin For Iv/Im Use (Monoclonal)Inj 300Mcgpfs/Vial , Inj Anti Snake Venominj Polyvalent 10 Ml (Lyophilized)10 Ml Vial , Inj Antitetanus Immunoglobulinsinj 250 Iu/Vialvial , Inj Artesunateinj 60 Mg /Vialvial , Inj Artesunatepowder For Injection 120 Mg , Inj Atracurium 10 Mg/ Ml2.5 Ml Amp , Inj Atropine 0.6 Mg/ Ml2 Ml Amp , Inj Bendamustineinj 100 Mg , Inj Benzathine Penicilline12 Lakh Iu/Vialvial , Inj Benzathine Penicilline6 Lakh Iu/Vialvial , Inj Betamethasone 4 Mg/Ml1 Ml Amp , Inj Betamethasone Sodium Phosphateinj 4 Mg/ Ml1 Ml Amp , Inj Biphasic Isophane Insulininsulin Biphasic Aspart 30:70 100 Iu/Ml (Firm Has To Supply Compatible Pen Along With Cartridges As And When Required Without Any , Inj Bleomycininj 15 Mg , Inj Bortezomib 2 Mg , Inj Bupivacaine Hcl 0.5% 20 Ml Vial , Inj Caffeine Citrateinj 20 Mg/ Ml3 Ml Vial , Inj Calcium Gluconateinj 10%10 Ml Vial , Inj Carboprost (15-Methyl Pgf2a)Inj 250Mcg1 Ml Amp , Inj Cefotaximeinj 1Gm/Vialvial , Inj Cefotaximeinj 250 Mg/Vialvial , Inj Cefotaximeinj 500 Mg/Vialvial , Inj Ceftazidimepowder For Injection 1Gm , Inj Ceftazidimepowder For Injection 250 Mg , Inj Ceftriaxoneinj 1 Gm/Vialvial , Inj Ceftriaxoneinj 250 Mg/Vialvial , Inj Ceftriaxoneinj 500 Mg/Vialvial , Inj Chloroquineinj 40 Mg/ Ml5 Ml Amp , Inj Chlorpheniramineinj 10 Mg/ Ml10 Ml Vial , Inj Ciprofloxacininj 200 Mg/100 Ml100 Ml Ffs Bottle , Inj D-10 (Dextrose 10%)Iv Fluid (Dextrose 10%)500 Ml Ffs Bottle , Inj D-25 Injection (Dextrose)Iv Fluid (Dextrose 25%)100 Ml Bottle , Inj D-25 Injection (Dextrose)Iv Fluid (Dextrose 25%)500 Ml Bottle , Inj Decarbazine 200 Mg10 Mg /Ml , Inj Desferrioxamineinjection 500 Mgvial , Inj Dexamethasoneinj 8 Mg/2 Ml2 Ml Vial , Inj Dextrose 5%Iv Fluid(Dextrose 5%)500 Ml Ffs Bottle , Inj Dextrose With Salinei/V Fluid (Dextrose 5% + Saline 0.9%)500 Ml Ffs Bottle , Inj Diazepam 5 Mg/ Ml2 Ml Amp , Inj Diclofenac 25 Mg/ Ml3 Ml Amp , Inj Dicyclomine Hydrochloride 10 Mg/ Ml2 Ml Amp , Inj Diltiazeminjection 5 Mg/Ml , Inj Dobutamineinj 50 Mg/ Ml5 Ml Amp , Inj Dopamineinj 40 Mg/ Ml5 Ml Amp , Inj Doxorubicininj 50 Mg , Inj Drotaverine 40 Mg/2 Ml2 Ml Amp , Inj Drotaverineinj 40 Mg/2 Ml2 Ml Amp , Inj Duvadilan 5Mgvial , Inj Enoxaparin Inj 40 Mg Equivalent To-4000 Iuvial/Pfs , Inj Erythropoietininjection 10000 Iu/Ml , Inj Erythropoietininjection 2000 Iu/Ml , Inj Esmolol 10 Mg/Ml , Inj Etophylline +Theophylline 220 Mg/2 Ml (169.4+50.6 Mg)2 Ml Amp , Inj Fentanyl50 Microgram/Ml2 Ml Amp , Inj Ferric Carboxymaltose50mg/Ml20 Ml Vial , Inj Fluphenazineinjection 25Mg1ml Vial/ Ampoules , Inj Fulvestrantinj 500 Mg , Eye Drop Flurbiprofen+Methylcellulose , Inj Furusemideinj 10 Mg/ Ml2 Ml Amp , Inj Gentamicininj 40 Mg/ Ml2 Ml Amp , Inj Glucose (A) + Sodium Chloride (B)Injection 5% (A) + 0.9% (B)500Ml Ffs , Inj Glycopyrolate 0.2 Mg/ Ml1 Ml Amp , Inj Haloperidolinj 5 Mg/ Ml1 Ml Amp , Inj Heparin Inj 1000 Iu5 Ml Vial , Inj Hepatitis B Immunoglobulin100 Iu/Vialvial , Inj Human Chorionic Gonadotropininjection 10000 Iuvial Of 1 Ml Injection , Inj Human Chorionic Gonadotropininjection 5000 Iuvial Of 2 Ml Injection , Inj Hyaluronidase 1500Iu , Inj Hydrocortisoneinj 100 Mg/Vialdry Powder 100Mg/Vial , Inj Hydroxyethyl(6% Saline Solution For Infusion)Starch 6%Ip , Inj Hyoscine Butylbromide20mg /Ml1 Ml Vial/Amp , Inj Ifosfamideinj 1 Gm , Inj. Deferoxamine500mg/Vial , Inj Insulin Solubleinj 40 Iu/ Ml10 Ml Vial , Inj Irinotecaninj 100 Mg , Inj Iron Sucroseinj 100 Mg/5 Ml5 Ml Amp , Inj Iv Human Immunoglobin 5% Iv Ig(5Mg/100Ml Each), , Inj Ketamine 10 Mg/ Ml10 Ml Vial , Inj Labetalolinj 20 Mg/4 Ml4 Ml Amp , Inj Labetalolinjection 5 Mg/Ml , Inj Lignocaine 2% 30 Ml Vial , Inj Lignocaine+Adrenaline 2% + 0.005 Mg/ Ml30 Ml Vial , Inj Lorazepaminj 2 Mg/ Ml1 Ml Vial , Inj Magnesium Sulphate 500 Mg/Ml , Inj Mannitolinj 20%100 Ml Ffsbottle / 350 Ml Ffs Bottle , Inj Medroxy- Progesteroneacetateinjection 150 Mg1 Ml / Vial , Inj Mephentermine 30 Ml Vial Mg/Ml10 Ml Vial , Inj Meropenem500 Mgvial , Inj Methyl Ergometrine Maleate 0.2 Mg/ Ml1 Ml Amp , Inj Methylprednisoloneinjection 1000 Mg/Mlvial , Inj Methylprednisoloneinjection 500 Mgvial Of 4 Ml , Inj Metoclopramideinj 5 Mg/ Ml2 Ml Amp , Inj Metronidazole 500 Mg/100 Ml100 Ml Ffs Bottle , Inj Midazolam 1 Mg/ Ml 5 Ml Amp/ 10Ml Vial , Inj Morphine 10 Mg/ Ml1 Ml Amp , Inj Morphineinjection 15 Mg/Mlvial , Inj Naloxoneinj 0.4 Mg/ Ml1 Ml Amp , Inj Neostigmine 0.5 Mg/ Ml1 Ml Amp , Inj Nitroglycerine (Glyceryl Tri Nitrate)Inj 25 Mg/5 Ml5 Ml Amp , Inj Noradrenalineinj 2 Mg Base/2 Ml Amp.2 Ml Amp , Inj Ondansetroninj 2 Mg/ Ml2 Ml Amp , Inj Oxytocin Injection 5Iu/Mlinjection 5 Iu/Ml1 Ml Ampule , Inj Pantoprazoleinj 40 Mg/Vialvial , Inj Paracetamol150 Mg/ Ml2 Ml Amp , Inj Pemetrexedinj 500 Mg , Inj Pentazocine 30Mg/Ml1 Ml Ampule , Inj Pheniramineinjection 22.75 Mg/Ml2 Ml Vial , Inj Phenobarbitoneinj 200 Mg1 Ml Amp , Inj Phenytoininj 50 Mg/ Ml2 Ml Amp , Inj Phytomenadione 10 Mg/Ml10 Mg Ampule , Inj Pioglitazone15mg , Inj Piperacillin +Tazobactam 4.5 Gm/Vialvial , Inj Pralidoxime (Pam)Inj 25 Mg/ Ml20 Ml Amp , Inj Premix Insulin30:70 Injection (Regular:Nph)2 , Inj Premix Insulin30:70 Injection 40 Iu/Ml , Inj Promethazine 10 Mg/Mlone Injection 1 Vial , Inj Promethazine 50 Mg (25Mg/ Ml)2Ml Vial/Ampoules , Inj Propofal 10 Mg/Ml1 Ml /Vial , Inj Protamine 50 Mg/5 Ml , Inj Quinineinj 300 Mg/ Ml2 Ml Amp , Inj Rabies Immunoglobulin300 Iu/2 Ml2 Ml Vial , Inj Rabies Vaccine (Cell Culture) Id/Iminj 2.5 Iu/ Ml1 Ml Vial , Inj Ranitidineinj 50 Mg/2 Ml2 Ml Amp , Inj Ringer Lactatei/V 0.24 % V/V Of Lactic Acid ( Eq. To 0.32% W/V Of Sodium Lactate), 0.6 % W/V Sodiumloride, 0.04 % W/V Potassium Chloride And 0.027 % , Inj Risperidone50 Mgvial Of 2 Ml , Inj Rituximabinj 500 Mg , Inj Sodium Bicarbonate Inj7.5% W/V10 Ml Amp , Inj Sodium Chloride - Hypotonicinj N/2(0.45%)500 Ml Ffs Bottle , Inj Sodium Chloride - Isotonicinj 0.9% Isotonic(Equivalent To Na+154 M Mol/L, Cl+154 M Mol/L)100 Ml Ffs , Inj Sodium Chloride - Isotonicinj 0.9% Isotonic(Equivalent To Na+154 M Mol/L, Cl+154 M Mol/L)500 Ml Ffs , Inj Streptokinaseinjection 15 Lac/Vialvial , Inj Succinyl Choline 50 Mg/ Ml10 Ml Vial , Inj Surfactant Suspension 25 Mg/Ml100 Ml Vial , Inj Thiamineinjection 100 Mg/Ml1 Ml/Vial , Inj Thiopentone 0.5Gm Powder/Vial20 Ml Vial , Inj Topotecaninj 4 Mg , Inj Tramadol 50 Mg/ Ml2 Ml Amp , Inj Tranexamic Acid 500 Mg/5 Ml.5 Ml Amp , Eye Drop Tropicamide And Phenyephrine , Inj Trastuzumabinj 440 Mg , Inj Urokinase(5 Laciu)Vial , Inj Vancomycinpowder For 1 G , Inj Vancomycinpowder For Injection 250 Mg , Vvancomycinpowder For Injection 500 Mg , Inj Vecuronium 2 Mg/ Ml2 Ml Amp , Inj Verapamil 5 Mg/2 Ml , Inj Vinblastininj 10 Mg , Inj Vinorelbineinj 10 Mg , Inj Vitamin B12 ,Injection500 Mcg/Ml(30 Ml Amp/ Vial) , Inj Vitamin K11 Mg/0.5 Ml0.5 Ml Amp , Inj Water For 2 Ml Amp , Inj Water For 5 Ml Amp , Drop Atropine1% Eye Drops5 Ml Vial , Drop Boro-Spirit Ear Drops-0.183 Gm Boric Acid In 2.08 Ml Of Alcohol , Drop Carboxy Methyl Celluslose 10 Ml , Drop Carboxymethyl-Cellulosedrops 0.5%10 Ml/Vial , Drop Ciprofloxacineye / Ear Drop 0.3%5 Ml Vial , Drop Combo Ear Drop- Chloramphenicol 5% W/V+Clotrimazole 1%+Lignocainehydrochloride 2%Combo Ear Drop- Chloramphenicol 5% , Drop Dexamethasonedrop(0.1%, 5Ml),Eye 5Ml Eye Drop , Drop Fluconazoleeye3 Mg/Ml(10 Mlvial),Eye Drop10 Ml , Drop Gentamicin Ear(0.3%)5 Ml Vial , Drop Homatropine 2% , Drop Lantanoprost0.005%(5Ml),Eye 5Ml , Drop Moxifloxacin0.5% W/V(5 Ml),Eye 5Ml , Drop Moxifloxacin+Prednisolone Eye Drop , Drop Moxifloxacin+Dexamethasone Eye Drop , Drop Normal Salinenasal Drops: Sodium Chloride Drops 0.05% W/V , Drop Paracetamol- 125Mg/Ml15 Ml Bottle With Dropper , Drop Pilocarpine 4%5 Ml Bottel , Drop Pilocarpinedrops 1%5 Ml Bottel , Drop Pilocarpinedrops 2%5 Ml Bottel , Drop Phenyl Mercuric Nitrate And Sodium Chloride 5 , Drop Phenyl Mercuric Nitrate And Sodium Chloride 6 , Drop Gatifloxacin(0.3% ), Eye Drop , Drop Prednisolonedrops 1%10 Ml Bottel , Drop Sodium Aminosalicylate Granules10 Gm , Drop Timolol0.5% Eye Drops5 Ml Vial , Drop Tropicamidedrops 1%5 Ml Drop , Drop Wax Solvent Ear Benzocaine2.7% W/V10 Ml Bottel Drop , Drop Wax Solvent Ear Drops: Paradichloro- Benzene2 % W/V10 Ml Bottel , Drop Xylometazolinenasal Drops 0.05 %, , Drop Xylometazolinenasal Drops: Adult (0.1%) , Inhaler Halothane 250 Ml Bottle , Inhaler Isoflurane 250 Ml Bottle , Inhaler Oxygen , Inhaler Ipratropium Inhalation (Mdi/Dpi)20 Mcg/Dose Ipratropium Respirator Solution , Inhaler Tiotropium Inhalation(Dpi) 18 Mcg/Dose , Inhaler Tiotropium Inhalation(Dpi) 9 Mcg/Dose , Inhaler Salbutamol Inhaler 100Mcg/Dosemetered Dose Container , Ointment Hydrocortisone 0.5% , Ointment Hydrocortisone 1% , Ointment Povidone Iodine5% Ointment15 Gram Tube , Ointment Acyclovir3% -5Gm Tube , Ointment Gum Paint Tannic Acid 2% , Ointment Betamethasone 0.05% 15 Gm , Ointment Aceclofanac + Linsed Oil + Methyl Salicylate + Menthol 30Gm , Syp Dextromethorphan 10 Mg/5 Ml100 Ml Pack Bottle , Syp Albendazole200mg/5 Ml10 Ml Bottle , Syp Ambroxol Hcl 15Mg + Terbutaline Sulphate 1.25Mg + Guaiphenesin 50Mg 5Ml ((Additional Composition Of Menthol Also Acceptable) 100Ml Bottle), Syrup , Syp Ambroxol Hcl 15Mg + Terbutaline Sulphate 1.25Mg + Guaiphenesin 50Mg , Syp Amoxycillin+Clavulanic Acid (Amoxicillin 200Mg+ Clavulanic Acid , Syp Azithromycinsyp 200Mg/5Ml15 Ml Bottle , Syp Bromhexine Syp 4Mg/5Ml50 Ml Bottle , Syp Caffeine Oral Liquid 20 Mg/Ml , Syp Carbamazepine Oral Liquid 100 Mg/5 Ml , Syp Cefixime + Clavunate 50+31.25Mg , Syp Cefixime Oral Suspension 100Mg/5Ml10 Ml Bottle , Syp Cefpodoxime + Clavunate 30Ml , Syp Cephalexinsyp 125Mg/5Ml30 Ml Bottle , Syp Cetirizinesyp 5Mg/5Ml30 Ml Bottle , Syp Chloroquinesyp 160Mg /10Ml(50Mg/5Ml Base)60 Ml Bottle , Syp Chlorpheniramine Maleate (Paracetamol 125Mg + Phenylpherine 5Mg + Cpm 0.5Mg + Sodiym Citrate 60Mg + Menthol 1Mg) , Syp Codeineoral Solution 15 Mg/5 Ml60 Ml Bottle , Syp Diphenhydramine 100Ml , Syp Diethylcarbamazine Oral Liquid 120 Mg/5 Ml , Syp Domperidone1mg Per 1Ml Suspension30 Ml Bottle , Syp Doxycyclinedry50 Mg/5 Ml , Syp Gum Paint (Tannic Acid)2% W/V15 Ml Bottle , Syp Hydroxyzine 10 Mg/5 Ml , Syp Iron & Folic Acidsyp Iron Each 1 Ml Contains 20Mg Elemental Iron+Folic Acid , Syp Lactulosesolution 10 Gm /15 Ml100 Ml Bottle , Syp Levosalbutamol50mcg/Dose , Syp Levosulbutamol 100 Mcg , Syp Levocetirizine + Monteleukast((2.5 Mg + 4 Mg) / 5 Ml, 30 Ml Bottle) , Syp Levocetirizine + Monteleukast 2.5 Mg + 4 Mg / 5 Ml(60 Ml Bottle,Suspension),Suspension , Syp Metronidazoleoral Suspension 200 Mg/5Ml60 Ml Bottle , Tab. Isoniazid 150Mg , Tab. Isoniazid 300Mg , Tab. Pyrazinamide 500Mg , Tab. Pyrazinamide 400Mg , Tab. Pyrazinamide 500Mg , Tab. Pyrazinamide 750Mg , Syp Montelukast Syrup60 Ml Bottle , Syp Multivitamin With Protein 200 Ml , Syp Ondansetronsyp 2Mg/5 Ml30 Ml Bottle , Syp Ofloxacin + Ornidazole (50 Mg + 125 Mg) / 5Ml 30 Ml Bottle(30 Ml),Suspension , Syp Paracetamol 125Mg/5 Ml60 Ml Bottle , Syp Pediatric Solution Like Isolyte P, N/2 & N/5Pediatric Solution Like Isolyte P, N/2 , Syp Potassium Chlorideoral Solution 100Mg/Ml200 Ml Bottle , Syp Promethazinesyp 5Mg/ 5Ml60 Ml Bottle , Syp Salbutamol Syp 2Mg/5Ml60 Ml Bottle , Syp Sodium Valproate Each 5Ml Contains 200Mg200 Ml Bottle , Syp Sucralfate 1Gm/5Ml100ml Bottle , Syp Sulfamethoxazole+Trimethoprimoral Liquid ( 200Mg +40 Mg) / 5 Ml50 Ml Bottle , Syp Vitamin A 100000 Iu/Ml With Marked Spoon For 1Ml &2Ml100 Ml Bottle , Tube Atropine1% Eye Ointment3 Gram , Tube Atropinesulphate 1%, , 3 Gm , Tubebenzoyl Peroxidegel 5% , Tube Betamethasone Dipropionateointment 0.05%15 Gram , Tube Chloramphenicoleye Ointment 0.5%4G/5G , Tube Ciprofloxacineye Ointment 0.3%3/3.5 Gram , Tube Clotrimazole Cream2%W/W15 Gram , Tube Diclofenac 0.01 , Tube Diclogenac + Linseed Oil 3% + Methyl Salicylate 10% + Menthol 5% , Tube Duvadilan10 Mg10x50 , Tube Framycetin Sulphate1% Cream30 Gram , Tube Fusidic Acidcream/Ointment 2%5 Gram , Tube Lignocaine 2% 30 Gram , Tube Miconazolecream 2% W/W15 Gram , Tube Mupirocincream/Ointment 2%5 Gram , Tube Povidine-Iodine Germicidegargle 20% W/V , Tube Salicylic Acidointment 6% 30 Gm , Tube Silver Sulphadiazine Cream Usp 1% 25 Gram , Tab / Cap. Cycloserine 100Mg , Tab. Linozolid 600Mg , Protin Powder , Combo Pack Artesunate + Sulphadoxine + Pyrimethamine (Age Group 15 Or Above)Tab Artesunate 200 Mg(3Tab) + Sulphadoxine 750 Mg(2Tablets) + Pyrimethamine , Combo Pack Artesunate + Sulphadoxine + Pyrimethamine (Age Group 9 To 14 Years)Tab Artesunate 150Mg (3Tab)+ Sulphadoxine 500Mg (2 Tab)+Pyrimethamine 25Mg , Combo Pack Artesunate + Sulphadoxine + Pyrimethamine(Age Group Between 1-4 Years)Tab Artesunate 50 Mg (3 Tab) + Sulphadoxine 500 Mg(1 Tab) + Pyrimethamine 25 Mg , Combo Pack With Mifepristone + Misoprostol(1 Tablet Of Mifepristone 200 Mg And 4 Tablets Of Misoprostol 200Mcg)Combi Pack , Budesonide Nebulising Suspension Containing Budesonide 0.5 Mg/2 Ml2 Ml , Jelly Glycerin Oral Liquid , Oral Suspension Amoxycillin125 Mg/5 Ml30 Ml Bottle , Oral Suspension Chlorpheniramineoral Liquid 2 Mg/5 Ml , Oral Suspension Ibuprofen 100Mg/5Ml60 Ml Bottle , Oral Suspension Valproateoral Solution 200Mg/5Ml100 Ml Bottle , Bleaching Powder Containing Not Less Than 30% W/W Of Available Chlorine (As Per I.P)Containing Not Less Than 30% W/W Of Available Chlorine (As Per I.P) , Glucose Packet 75 Mg For Ogtt Testglucose Packet 75 Mg For Ogtt , Reduced Osmolarity Ors Pkt. Who Formulao.R.S. Glucose- 75Meq,Sodium- 75M Eq Or M Mol /L,Chloride - 65Meq Or M Mol/L, Potassium- 20Meq Or M Mol/L , Citrate- 10M Mol/L Osmolarity -245M Osm/L,Dextrose 13.5G/L Sodium Chloride 2.6G/L Potassium , Hydrogen Peroxide Solution 6% , Povidone Iodine Solution 5%,100 Ml Bottle , Adult Brief Daiper Set- Made Of Ultra Absorbent Material With Leakage Barrier & Having Soft, Flexible Leg Elastic. With Wetness Indicator. Made Up Of Woodpulp, Sap, Absorbent Nonwooven Fabric. The Set Contatin Two Pcs Of Medium Daiper {Nominal Size 81Cm-111Cm} For Waist Size 31-44 & Three Pcs Of Large Daiper {Normal Size 85Cm-128Cm} For Waist Size 34-50 , A V Fistula Sterilized Twin Needle(17 G (Two Needle Pack)),Consumable , A.V Fistula Needle - 16 No , A.V Fistula Needle - 17 G , A.V. Blood Line (Post Haemodialysis Tubing) , A.V. Blood Line (Post Haemodialysis Tubing) , A.V. Blood Line (Post Haemodialysis Tubing) High Quality , A.V. Blood Line (Post Haemodialysis Tubing) High Quality , Abdominal Belt(32 Inch Each),Consumable , Abdominal Belt(34 Inch Each),Consumable , Abdominal Belt(36 Inch Each),Consumable , Abdominal Belt(38 Inch Each),Consumable , Abdominal Drain Set 28 No , Abdominal Drain Set 32 No , Abdonel Belt Lsstandard Quality , Absolute Alcohol (Ethanol)(1X500 Ml = 500 Ml),Consumable , Absorable Surgical Suture Rb Needle Size No 1-0,30 Mm Length -70 Cm , 12 Foils Per Packet , Polyglycolic Acid (Pga) , Absorbable Gelatine Sponge Ip 80Mm X 50Mm X 10Mm , Absorbable Surgical Suture Braided Polyglycolic Acid 3/8 Circle Reverse Cuttingg(12Mm 45 Cmspatulated Needle),Consumable , Absorbent Cotton Roll 100 Gm Each Consumable , Absorbent Cotton Wool Ip 500 Grms (Each)(Roll),Consumable , Acetic Acid - Solution(3% 100 Ml Bottle),Consumable , Acetone Detection Kit , Acetone Detection Kit(100 Gm),Powder , Acetone Solution Pack Of 2.5 Ltr , Acralic Board (Sainaj Board Acralic Sheet) , Acralic Board (Sainaj Board Acralic Sheet) , Ad Syringe(0.1 Ml),For Vaccine , Ad Syringe(0.5 Ml),For Vaccine , Adhesive Plaster Usp 7.5 Cm X 10 Mts/Roll Cloth Based , Adhesive Plaster Usp 7.5 Cm X 5 Mts/Roll Cloth Based , Adhesive Roll 1 Inch X 5 M / Roll Cloth Based , Adhesive Tape 7.5Cm X10(Mtr/Roll),Consumable , Advanced Rf Energy Hand Instruments Of 12Mm Shaft Diameter For Open Procedureswith Shaft Lengths(22Cm And Should Be Both Hand & Foot Activated),Consumable , Advanced Rf Energy Hand Instruments Of 5Mm Shaft Diameter For Laparoscopic Procedures With Shaft Lengths (35Cm And Should Be Both Hand & Foot Activated With Curved Tip),Consumable , Advanced Rfenergy Hand Instrument Of 5Mm Shaft Diameter For Laparoscopic Procedure With Shaft Length 35Cm With 55Degree Articulation And Should Be Both Hand(Foot Activated),Consumable , Advanced Rfenergy Hand Instrument Of 5Mm Shaft Diameter For Laparoscopic Procedure With Shaft Length 45Cm And Should Be Both Hand(Foot Activated With Curved Tip),Consumable , Advanced Rfenergy Hand Instrument Of 5Mm Shaft Diameter For Open Procedure With Shaft Length 14Cm And Should Be Both Hand And( Foot Activated),Consumable , Advanced Rfenergy Hand Instrument Of 5Mm Shaft Diameter For Open Procedure With Shaft Length 25Cm And Should Be Both Hand And(Foot Activated),Consumable , Advanced Rfenergy Hand Instrument Of 5Mm Shaft Diameter For Open Procedure With Shaft Length 35Cm And Should Be Both Hand And(Foot Activated),Consumable , Albumin600 Ml(Model Ba 400 System (Mfg Bybio System)),Consumable , Albumin600 Ml(Model Ba 400 System ,Consumable , Alchlol Absouite 500Ml (Ethanol) 99.9% , Alcohal Based Hand Sanitizer(500Ml Bottle With Dispenser),Consumable , Alcohal Based Hand Sanitizer(500Ml Bottle With Dispenser),Consumable , Alkaline Phosphatase (Alp) Dea 300 Ml(Model Ba 400 System (Mfg Bybio System)),Consumable , Alkaline Phosphatase Kit (Kinetic) 10X2.2Ml 44 Test/Kit Consumable , Alkaline Phosphate Kinetic 2*25 Ml(Semi Auto End Point),Consumable , Alkaline Phosphate(100 Ml (5 X 20)),Consumable , All Human (Bovine Aprotinin Free) Fibrin Sealant(1 Ml),Consumable , All Human (Bovine Aprotinin Free) Fibrin Sealant(2 Ml),Consumable , All Out Refill , All Out With Refill , Almehra Iron 6X3x1.5”, 22 Gauge , Alphacypermetherin 5% Wdp , Alt/Gpt 600 Ml , Alumeium Bartan , Aluminium Potassim Sulphate (Each),Consumable , Ambu Bag / Adult Each -1700Ml, With Oxygen Connecting Tube ,Should Be Supplied With A Carry Pouch , Ambu Bag Should Be Complete With Required Autoclavable Valves And Other Accessories,(Should Have Silicon Rubber Bellow To Withstand Autoclave At 134 Deg.C),Consumable , Ambu Bag / Resuscitator Silicon 200-250 Ml Infant Size-Each, With Oxygen Connecting Tube ,Should Be Supplied With A Carry Pouch , Ambu Bag Should Be Complete With Required Autoclavable Valves And Other Accessories,(Should Have Silicon Rubber Bellow To Withstand Autoclave At 134 Deg.C) Should Be Multiple Times Autoclavable), Consumable , Aminoacid (Essential) Infusion(10% 100Ml Ffs Bottle),Bottle , Ammonium Sulphate (Analar (Gr/Ar) (1X500 Gm = 500Gm), Consumable , Anc Table 6X3x3 Of Iron , Anteriar Veginal Wall Retractor , Anti A Sera Igm(10 Vial),Consumable , Anti Abd Grouping Serum 3X10mlconsumable , Anti B Sera Igm(10 Vial),Consumable , Anti Malaria Larva Oil Harbal Based , Anti-D (Polyvalent)(1X10 Ml),Consumable , Antiseptic Concentrate For Floor Clening Pack Of 50 Litt. Can , Apit(2X4 Ml),Consumable , Apo-A(100 Tests),Consumable , Apo-B(100 Tests),Consumable , Asdesive Lable For Sputam Container , Aso Kit(25 Test/Packet),Consumable , Ast/Got 600 Ml , Attandent Bed Powder Coted 84Lx24Wx18H , Auramine O , Auto Clave (Poratable) Single Drum Aluminum Seamless Construction Made Of Albminium Alloy With Turning On Lid Highly Polished. It Comes With One Stop Cock (Continus Bleeding Valve) Safety Valve And Pressure Guage Size 12X12X12X20 , Auto Cleanser For Cbc Machine(2 Liter),Consumable , Auto Dill Solution For Cbc Machine(20 Liter),Consumable , Auto Lyser Solution For Cbc Machine(500Ml),Consumable , Auto Pippets Fixed Volume 10 Micro Liters Each Syring , Auto Pippets Fixed Volume 10 Micro Liters Each Syring , Auto Pippets Fixed Volume 1000 Micro Liters Eachsyring , Auto Pippets Fixed Volume 1000 Micro Liters Eachsyring , Auto Pippets Fixed Volume 20 Micro Liters Each , Auto Pippets Fixed Volume 20 Micro Liters Each Syring , Autoclave Ss , Double Walled Size (12X22) With Stand (Manual) Isi Marked , Autoclave Ss , Double Walled Size (16X24) With Stand (Manual)Isi Marked , Autoclave Ss , Electric Operated Size (12X14)With Stand , Autoclave Ss , Electric Operated Size (12X20) With Stand , Autoclave Ss , Eletric Operated Size (12X22)With Stand , A-V Blood Lines With Av Pressure Transducer Protector For All Machines Types And Dialysers (Acceptable For Fitting To All Standard Dialysers), Set , A-V Blood Lines With Av Pressure Transducer(Acceptable For Fitting To All Standard Dialyzers ) With Side Tubing- (For Heparinization And Av Pressure Monitoring) Ce And Iso Certificate Essential With Protector For All Machines Types And Dialysers(Post-Pump Tubing Sets Options Medical Grade Clear Tubing Guarded Access Ports For Reduced Infection Risks Parts Of Superior Quality, Each),Consumable , A-V Blood Lines With Av Pressure Transducer(Acceptable For Fitting To All Standard Dialyzers ) With Side Tubing- (For Heparinization And Av Pressure Monitoring) Ce And Iso Certificate Essential With Protector For All Machines Types And Dialysers(Post-Pump Tubing Sets Options Medical Grade Clear Tubing Guarded Access Ports For Reduced Infection Risks Parts Of Superior Quality, Each),Consumable , Axjust Cooler Plastic Body Standard Size , B.B Silk (12 Foils/Pkt)(3/8 Rcut Needle 45 Mm Length 76 Cm, Size 2/0)),Consumable , B.B Silk Size-3/0 (12 Foils/Pkt)(3/8Cir Rcut Needle 26Mm Length 76 Cm),Needle , B.B Silk With 1/2 Cir Rb Needle Size:1/0 20 Mm Length 75 Cm Non Absorbable Surgical Sutures Usp Surgical Material , B.B Silk With 1/2 Cir Rb Needle Size:2/0 30 Mm Length 75 Cmsurgical Material , B.B. Silk 6 Reels X 25 Mts Length 25 Mts. Black Braided Silk Without Needle In Reels Non Absorbable Surgical Sutures Usp 3-0(6 Reels Is Per Box Rate Should Be Quoted For 6 Reels),Consumable , B.B. Silk 6 Reels X 25 Mts Length 25 Mts.Black Braided Silk Without Needle In Reels Non Absorbable Surgical Sutures Usp-, 2-0(6 Reels Is Per Box Rate Should Be Quoted For 6 Reels ),Surgical Material , B.B. Silk 6 Reels X 25 Mts Size:1/0(6 Reels Is Per Box Rate Should Be Quoted For 6 Reels),Surgical Material , Babcock- Laparoscopic 10Mm A Traumatic Babcock, Straight 360 Degree Rotating With Insulated Shaft, A Traumatic Jaws With Ratchet Mechanism, Plastic Grip(36 Cms Length, Independently Moving Jaws),Consumable , Babcock- Laparoscopic 5Mm A Traumatic Babcock, Straight 360 Degree Rotating With Insulated Shaft, A Traumatic Jaws With Ratchet Mechanism, Plastic Grip(36 Cms Length, Independently Moving Jaws),Consumable , Baby Diapers Small (10 Diaper Per Pkt) Standard Company , Baby Feeding Spoon , Baby Feeding Spoon Feeding Of Milk , Baby Oxygen Maskall Sizes , Baby Shuit , Baby Towile , Baby Tray Ss 15X18Of Ss With Cover Pack Of Of Ss With Cover , Bag Cayring (Bag) , Bag For Carrying Kit/Material During Home Visit , Balanced Salt Solution 500 Mlbottle(Each),Consumable , Barium Chloride 10% (500 Ml Bottle) , Barraquer Wire Speculum, Large(Num),Consumable , Basic Carbol Fuchsin For Afb Staining 25 Gm/Pkt , Basic Fuchine 25Gm (Dye Content 85% To 88%) , Basic Fuchisin(Sep.Chemical Name: Pararosaniline Hydrochloride,Chemical Structure: C20h20c1n3 Mol Wt:337.86, Dye Content: Approx 85%-88% &Dye Content Must Be Mentioned) Colour Metallic Green. , Battery 70D 26 Rmf For Vehicle , Bed Pan Female With Cover (Made Of Stainless Steel) , Bed Pan Male With Cover (Made Of Stainless Steel) , Bed Side Bench , Bed Side Locker Ss , Bedside Locker Standard Size Ss Top , Benedicts Qualitative Reagent(1X5 Lit),Consumable , Bilirubin (Direct) As 300 Ml ,Consumable , Bilirubin (Total) 600 Ml,Consumable , Bilrubin Total & Direct Auto 3X100ml (Span/Tulip/Erba) , Bio Hazard Labels , Bio Metric Attance Machin Menul Operated , Bio Metric Attance Machine Online Operated , Biochemistry Calibrator 5X5 Ml Consumable , Biochemistry Control Serum L1 5X5 Ml , Biochemistry Control Serum L2 5X5 Ml (Consumable , Biomedical Waste Collection Plastic Bag(Yellow)(450X450 Mm 55 Micron 100/Pkt),Consumable , Biomedical Waste Collection Plstic Bag(Black 750 X 900 Mm 55 Micron 100/Pkt),Bag , Biomedical Waste Collection Plstic Bag(Black 900 X 900 Mm 55 Micron 100/Pkt),Bag , Biomedical Waste Collection Plstic Bag(Blue 750 X 900 Mm 55 Micron 100/Pkt),Bag , Biomedical Waste Collection Plstic Bag(Blue 900 X 900 Mm 55 Micron 100/Pkt),Bag , Biomedical Waste Collection Plstic Bag(Red 750 X 900 Mm 55 Micron 100/Pkt),Bag , Biomedical Waste Collection Plstic Bag(Red 900 X 900 Mm 55 Micron 100/Pkt),Bag , Biomedical Waste Collection Plstic Bag(Yellow 750 X 900 Mm 55 Micron 100/Pkt),Bag , Biomedical Waste Collection Plstic Bag(Yellow 900 X 900 Mm 55 Micron 100/Pkt),Bag , Bio-Membrane( ),Consumable , Black Disinfectant Fluid90% Pure Pack Of 20 Litt , Black-Braided Silk With 1/2 Cir Cutting Needle 30Mm Length 75 Cm(1/0 12 Foils/Pkt),Consumable , Black-Braided Silk With 1/2 Cir Rb Needle 20 Mm Length 75 Cm 1/0 13 Foils/Pkt , Black-Braided Silk With 1/2 Cir Rb Needle 30 Mm Length 75 Cm 2/0 12 Foils/Pkt , Blanket For Baby , Blankets For Neonates , Bleaching Powder 25Kg Bag , Bleaching Powder Gr-Ii Is 1065/1989 With Upto Datepacked In 25 Kg Hdpe Bags Isi Marked Stable Consumable , Blood Culture Media Mycobacterium Spp(Bact/Alert Mp (Plastic)),Each , Bowelss Size 20 , Blood Administrations Set Adult , Blood Bag Refrigerator For 150 Bags Isi Mark Standard Company , Blood Bag Refrigerator For 300 Bags Isi Mark Standard Company , Blood Bag Refrigerator For 60 Bags Isi Mark Standard Company , Blood Bag Warmer , Blood Bag With Acd/Cpd Solution (Disposable Sterilised) With Needle(100 Ml),Bag , Blood Bag With Acd/Cpd Solution (Disposable Sterilised) With Needle(350 Ml),Bag , Blood Bank Refrigerator , Blood Cell Counter Key(Key),Consumable , Blood Culture Media Aerobic For Adult(Bact/Alert Fa Plus),Each , Blood Culture Media Aerobic For Pediatric(Bact/Alert Pf Plus),Each , Blood Culture Media Fungus- Bottles Per Year, Fungus Can Be Tested By All Quoted Bottles. In The Same Bottle Bacteria And Fungus Can Be Tested.; Fungus Can Be Tested By All Quoted Bottles. In The Same Bottle Bacteria And Fungus Can Be Tested.(-),Consumable , Blood Gluose (God/Pod) Semi Auto End Point(1000 Ml),Consumable , Blood Grouping Anti Sera A Monoclonal(10 Ml Vial),Consumable , Blood Grouping Anti Sera B Monoclonal : Antisera Should Be Transparent With More Than One Year Shelf Life At 2-6 C , It Should Give +++ Agglutination At 1.256 Dilution In 3-4 Sec With B Positive Cells 10 Ml , Blood Grouping Anti Sera B Monoclonal(10 Ml Vial),Consumable , Blood Grouping Anti Sera D Monoclonal :-Antisera Should Be Transparent With More Than One Year Shelf Life At 2-6 C, It Should Give +++ Agglutination At 1.256 Dilution In 3-4 Sec With D Antigen Positive Cells. 10Ml Vail (Eryclone Anti-D Igm) , Blood Grouping Anti Sera D Monoclonal(10 Ml Vial ,Consumable , Blood Transfusion Chair , Blood Urea (Bun) Uv(1000 Ml),Consumable , Blood Urea Reagent Kit(200Ml (2X100ml)),Consumable , Blood Urea(Arba),Consumable , Blood Vessel Introducers Needles 16G, Sterilized, Set , Bloting Paper(Paper),Consumable , Boiling Flask 2Lt , Boiling Flask 5Lt , Bottel Plastic 2Lt , Bovine Albumin (22% W/V)(1X5=5 Ml),Consumable , Bowel Baual Ss Size 8 Powder Coated , Bowl Plastic 50X30 , Bp Stument Cell , Bp Stument Marcury Isi Mark , Brain Thromboplastin For Prothrombin Time (Pt Reagent) 5Ml (Liquiplastin) , Broom Stick For Sputum Smear Prepration (8 Inches) , Brown Tap (2 Inches) , Bubble Cpap Machine , Bucket Brackets (For Hanging Set Of Single Fire Buckets) With Out Fire Bucket , Bucket Brackets (For Hanging Set Of Three Fire Buckets) With Out Fire Bucket , Burn Cage (Bed Cradle) , Cabinate Plain (Cr Sheet 1.00 Mm) Size 1675X840x480 Mm (Iron) , Cabinate Plain (Cr Sheet 1.00 Mm) Size 1980X915x480 Mm (Iron) , Cabinet Full Size (78X3619) Sheet Gauge 20 (Iron) , Calcium Arsenazo 600 Ml,Consumable , Capillary Tube 100 Piecesconsumable , Capillary Tube Biluribin Pack Of 100 Pieces , Carbol Fuchsin For Zn Stain (500Ml Bottle) (Becon) , Carbol Fuchsin For Zn Stain (500Ml Bottle) (Ranbaxy) , Carbol Fuchsin For Zn Stain (500Ml Bottle) (Star) , Carbolic Acid (Phenol) - Spc. Chemical Structure C6h50h, Molecular Wt: 94.11, Melting Point : 40 Digree C 2, Purity : 99.5% , Carbondioxide Gas In Medium Size Cylinder(B Type),Miscellaneous , Carbondioxide Gas In Small Size Cylinder(A Type),Miscellaneous , C-Arm Macchine , Cartain Complete(Cloth Silk With Ring And Stiching) , Catgut Chromic Size:2/0 Length 150 Cm , Catgut Chromic With 1/2 Cir Rb Needle 30 Mm Length 70Cm No. 1 -0, 12 Foils Per Packet , Catgut Chromic With 1/2 Cir Rb Needle 40 Mm Length 75Cm No. 1 Consumable , Catgut Chromic With 1/2 Cir Rb Needle 40 Mm Length 75Cm No. 2 Consumable(Each),Consumable , Cathetor Tray Ss With Cover 16X3 , Cassette(14 Inch X 17 Inch),Consumable For X-Ray , Cassette(8 Inch X 10 Inch),Consumable For X-Ray , Cc Camera 1/4 Ccd, 3.6 Mm Board Lens 380 Tvl 2 Lux Color Plastic/Dust Proof Metal Body Camera 2 Way Audio. Make;- Impex/Sparsh/ Grovers/Hinum/Vantage/Alpha/Vision. Model:-Cc-31/Bma-231/Hevs-209-3G/Hl110/Va- 2W380/Al-Col-106/Vaccs 200 , Cc Camera, 1/4 Ccd, 3.6 Mm Board Lens 380 Tvl 2 Lux Color Plastic/Dust Proof Metal Body Camera With Supply. Make;- Impex/Sparsh/ Grovers/Hinum/Vantage/Alpha/Vision. Model:-Cc-30/Bmc-430/Hev 20 01 /Hl109/Va-Ccs- Tvl2380/Al-Col-105A/Vaccs380s , Cc Camera, 1/4 Ccd, 3.6 Mm Board Lens 380 Tvl 2 Lux Color Plastic/Dust Proof Metal Body Camera. Make;- Impex/Sparsh/ Grovers/Hinum/Vantage/Alpha/Vision. Model:- Cc-72/Bmc-429/Dy-3723 Lph/Hl108/Va-Tvl380/Al-Col-104/Vaccs380 , Cc Camera, 10.1 Mega Pixle Cmos Sensor, Integreated Cleaning System, 2.5 Lcd Screen With 230K Pixle, 1600 Viewing Angle, High-Precision 9 Point Af System, Picture Style Image Processing Parameters, Digic Ii Image Processor With 0.2 Sec Start Up - (Each) , Cc Camera, 16 Channel Color Digital Video Recorder, 500 Gm Hdd, Full Triplex, Real Time Display (30 Frame Per Second) Make:- Impex/Sparsh/Grovers/Hinum/Vvantage/Alpha/Vision. Model:-Dv-62/Mcd-62/Dvr-29- Hk/Hl205dvr/Va-Hd500/Al-4C/B2616v , Cc Camera, 16 Channel Mono Chrome Duplex Multiplexer With Osd, Time Date And Alarm Facility, Make:-Impex/Sparsh/ Grovers/ Hinum/Vvantage/Alpha/Visionmodel:-M-41/Mx-16/Cplm-30-3/Hl202mx/Vaad16/Al-Mux- 16B/Vaad 16 , Cctv Cable, 3 Core + Coaxialfor 2 Way/Silent Camera, Make:- Impex/Sparsh/Grovers/Hinum/Vvantage/Alpha/Vision/Isi Model:-C-32/Cc-3/Alc-3C/Isi , Cd/Dvd Player , Ceiling Shadowless Lamp Double Dome Isi Marked , Ceiling Shadowless Lamp Single Domeisi Marked , Cell Clean For 5-Part Hematology Analyser All Model Consumable , Cell Pack For 5-Part Hematology Analyser All Model,Consumable , Cell Pack, Reagent Pack For Cell Counter((Erma And Mindrug) Complete Set),Consumable All Instement , Centeral Oxygen Supply For 10 Bedcomplete Fitting , Centeral Oxygen Supply For 30 Bedcomplete Fitting , Centeral Oxygen Supply For 5 Bed Complete Fitting , Central Venous Catheter Kit Single Lumen 18 G , Central Venous Catheter Kit(Single Lumen),Kit , Centrifuge Machine -12 Tube With Digital Display & Timer & Rpm , Centrifuge Machine -8 Tube With Digital Display & Timer & Rpm , Cervical Collar/Each-Soft, Medium Sized , Cervical Cotter , Chair Cushion Foam Thickness 3 With Cotton Cover Box Type , Chikungunya Card Test 1 Gg + 1 Gm (25 Test/Kit) , Chikungunya Card Test 1 Gg + 1 Gm (30 Test/Kit) , Children Toys 1- Jsvy] /Kkxs Ls [Khpus Okys F[Kyksus 2- Fcfymax Cykwdl] 3- Ckwdj Lcth ,Oa Qyksa Ds Vkdkj Okys Iykflvd F[Kyksus Vkfn 4- >Qu&>Qu 5- Iykflvd Ckwy , Chloroquine Solution 4 % Pack Of 5Ltr , Cholesterol600 Ml Consumable , Cholesterol Hdl Direct 160 Ml,Consumable , Cholesterol Kit End Point Enzymatic Kit 50 Test/Kit , Cholesterol Kit End Point Enzymatic Kit 5X20ml 200 Test/Kit , Cholestreol Kit Pack Of 10X10ml (Span/Tulip/Erba) , Chromic Catgut (12 Foils/Pkt)(Size:1/0 Length 150 Cm),Consumable , Chromic Catgut No 1.0 Round Dody, 40 Mm 12 Foils/Pkt , Chromic Size - 1, (12 Foils/Pkt)(1/2 Cir Rb Needle 40 Mm, Length 76 Cm),Needle , Chromic Size - 1, 12 Foils/Pkt(1/2 Cir Rb Needle 45 Mm, Length 100 Cm),Needle , Chromic Size - 1/0 (12 Foils/Pkt)(3/8 Cir Rb Needle 40 Mm, Suture Length 76 Cm),Needle , Chromic With 1/2 Cir Rb Needle 30 Mm Length 76Cm, 2-0 Usp, Absorbable Surgical Suture Surgical Material 12 Foils/Box , Chromic With 1/2 Cir Rb Needle 40 Mm Length 76 Cm (With Needle) ) Absorbable Surgical Sutures Usp,(Size 1, 12 Foils/Pkt),Surgical Material , Chromic With 1/2 Cir Rb Needle Size:1/0, 30 Mm Length 76Cm Absorbable Surgical Suture Surgical Material , Chromic With Cd Rb Needle 30 Mm Length 76 Cm Size:2/0 Absorbable Surgical Suture Surgical Usp, 12 Foils/Boxmaterial , Chromic With Cd.Rb Needle Absorbable Surgical Suture (12 Foils/Pkt)(40 Mm Length 76 Cm Size:1/0),Surgical Material , Chromic With St Rb Needle (12 Foils/Pkt)(60 Mm Length 76 Cm Size:2/0),Consumable , Cidex – 5Lter (2% Glutaldyhide) , Cidex Tray 10X5x3 , Cidex Tray 17X5x39 , Cidex Tray 26X53 , Cidex Tray 36X5x3 , Citric Acid Analar/Gr/Ar (1X500 Gm = 500Gm),Consumable , Cleanac-3 4000 Pack Size 5L(Cell Counter (Model No- Mek-6420P-Japan)),Consumable , Close Wound Drainage Device Under Negative Pressure(Closed Wound Suction Unit) Size 200 Ml(Catheter Size 18, Each),Consumable , Coagulometre Single Chanel , Coline 500Ml , Collagen Drysheet(20X40cm Sheet),Consumable , Collagen Drysheet(10X10cm Sheet),Consumable , Collagen Drysheet(15X30cm Sheet),Consumable , Collagen Wet(6X6 Cm),Sheet , Collection Vail 2Ml Pack 100 , Collection Vail 5Ml Pack 100 , Colorometre Digital , Colour Vision Chart , Complete Delivery Kit-1Plastic Desposable Gown (Non Woven Plastic Laminated,Leak Proof)-2(4*4),(2).Disposable Goggles For Protection Of Eyes-2 (Free Size),(3).Face Mask-2 Free Size,(4).Plastic Disposable Cap(Non Woven Plastic Laminated,Leak Proof)(1Pair,(5).Long Gloves Elbow Length-2Pairs(6 1/2 And 7),(6)Disposable Shoe Covers,Till Calf(Plastic)-2Pair(Free Size)As Per Attached Specification),Consumable [987797] , Computer Table (Size 4X2.6) With All The Fitting Of Parts , Computer Table 4’X2’ With All Fitting Of Parts , Con. (Hno3) Nitric Acid (2.5 Liter),Consumable , Conc Hcl (1X500 Ml = 500 Ml),Consumable , Conc Washing Solution500 Ml All Model Consumable , Conical Flask 2.5 Ltr , Conical Flask Cap. Of500ml Flat Bottal , Conical Flask Cap. Of 100Ml Flat Bottal , Conical Flask Cap. Of 2.5 Lit Falt Bottal , Coombs Ahg Sera 5Ml(Each),Consumable , Coombs Serum (Anti Human Globulin) (Polyvalent)(1X5=5 Ml),Consumable , Corrugated Drainage Sheet, Sterile, Multichannel, Single Use(2 Inch X 6 Inch (Pvc)-Piece),Consumable , Cotton Based Crape Bandage 10Cm X 4M (Box Of 10 Bandages) , Cotton Based Crape Bandage 15Cm X 4M (Box Of 10 Bandages) , Cotton Delivery Belt , Cover Slip With Isi Marked Size:18X18mm(+/- 1.00Mm),Thikness 0.13.. To 0.17Mm(Pkt Of 50 Pieces),Consumable , Cpap Machine , Cpk-Mb Kit (Kinetic) 25 Test/Kit , Cpk-Mb Kit (Kinetic) 25 Test/Kit , Creatinin Kit , Creatinine600 Ml(Model Ba 400 System),Consumable , Creatinine Calorimeter For Semi Auto Kinetic 4X60ml 480Test/Kit , Creatinine Kinetic Pack 2X50ml (Span/Tulip/Erba) , Cresent Knife(1 Each),Consumable , Crp (Hs)(100 Tests),Consumable , Crp Test Kit (Latex/Card) (25 Test/Kit) , Curved Scissors- Laparoscopic 5Mm Size, 360 Degree Rotating With Insulated Shaft, Non Ratchet , Plastic Grip(36 Cms Length, Monopolar Pin Provision For Usage With Electro Surgical Unit, Independently Moving Jaws),Consumable , Cushined Chair With Out Arm Size 865X410x450x500 Mm , Cushioned Chair With Arm Size 900X455x500x560 Mm , Cushioned Chair Without Arm Size 865X410x450x500 Mm , Cut Needle 48 Mm Stainless Steel Length(45 Cm Size 6),Needle 1/2 Ccs , Cvp Line Complete Set , Cvp Line Complete Set , Cyanemeth Solution For Hb 5 Litre , Cyanemeth Solution For Hb(Mfg By Beacon Diagnostic)(5 Lit Can),Consumable , Cylinder Brush , Cytochrome Stain With Buffer (500 Ml),Consumable [710030] , Cytoplasam Stain A&B Rapid Pap Pack Of 500Ml , D-Dimer(10X3 Ml),Consumable , D-Dimer(10X3 Ml),Consumable , Deaver Retractor Abdominal Central Oxygen Supply Complete Per Mtr , Dead Body Cover Standarad Quality , Defbrillator Biphasic, Features : Offers Variable Energy Level Selection, (2,3,5,7,10,20,30,50,70,100,150,200 Joules), Battery Capacity - 50 Shocks On Single Charge. Adult &Pediatric Paddles Support, Compact & Ligh Weight : Approx 5.0Kgs Max, Ecg Through Paddle , Dengurapid Test Card-Single Test , Dengu Card- Antigen(25 Card/Pkt),Consumable , Dengue Card Test 100 Test Kit , Dengue Card Test 100 Test Kit , Dental X-Ray Film Digital 1X150 , Dental X-Ray Film Size 31 X 41 Mm (150 Films / Pkt) , Desert Cooler 24” Exhaust Fan All Body Gi Sheet 22 Gauge , Desirepoly Bag Colour Sutable Forapprox 35Ltr Dustbeen , Desire Poly Bag Colour Sutable Forapprox 10Ltr Dustbeen , Desire Poly Bag Colour Sutable Forapprox 60Ltr Dustbeen , Desired Bio Hezard Poly Bag Capacity Of 30 Ltr , Desired Bio Hezard Poly Bag Capacity Of 50 Lit / 30 Lit. , Desired Bio Hezard Poly Bag Capacity Of 50 Ltr , Developer Powder (22.5 Ltr) For X-Ray , Developer Single Bath Liquid Concentrated Of Consistent Quality. It Sould Have Favoutable Contrast/Fog Ratio And Good Shelf Life - (5 Ltr Can To Make 22.5 Liters Working Solution) , Developer Single Bath Liquid Concentrated Of Consistent Quality. It Sould Have Favoutable Contrast/Fog Ratio And Good Shelf Life-2 Lit Can( To Make 9 Liters Working Solution) (Bromodex Mp Developer Concentrate) 9Ltr Packing , Developer Single Bath Liquid Concentrated Of Consistent Quality. It Sould Have Favoutable Contrast/Fog Ratio And Good Shelf Life-3 Lit Can( To Make 13.5 Liters Working Solution) (Bromodex Mp Developer Concentrate) 13.5 Ltr Packing , Diagnostic Strips For Urine Sugar/Albmin Packing: 100 Strip/Pkt , Dialysis Starting Kit Disposable:A)Sterile Tray With Top(Disposable),Size Not Less Than 30X30cm B) Sterile Drape Size Not Less Than 45X45 Cm 1No C) Cotton Ball 6 No D)(D) Cotton Gauze Pieces 1,E) Artery Forceps-1 No (Disposable)),Consumable , Dialysis Starting Kit Disposable:A)Sterile Tray With Top(Disposable),Size Not Less Than 30X30cm B) Sterile Drape Size Not Less Than 45X45 Cm 1No C) Cotton Ball 6 No D)Cotton Gauze Pieces 1 , Diamond Marke Pencil , Digital Ball Watch Standard Company , Digital Thermometer , Digital Wrist Watch , Digital X Ray Film (Pack Of 100)),Film Size4 Inch X 17 Inch D , Digital X Ray Film -10X12 (150 Films/Pkt) , Digital X Ray Film -11X14 (150 Films/Pkt) , Digital X Ray Film -8X10 (150 Films/Pkt) , Digital X-Ray Film Size 14 X 17((100 Sheet Per Packet)),Film , Digital X Ray Film(Dihl(Pack Of 150)),Film 10 Inchx 12 Inch , Digital X-Ray Filimdigital X Ray Film(Dihl(Pack Of 150)),Size Of Film 8 Inch X 10 Inch , Digtital Thrmometer , Digtital Wrist Watch , Dim/.Wt. W215xh285xd150 Mm/2.85Kg Protable Pa Amplifier Systems Wa 320Dpr 20 Watts (Power Output 25 W Max Input – 2Xmic 2.5Mv,1Xaux 125Mv Tone Controls Bass + 4Db At 200 Hz, Treble+ 5Db At 10Khz Power Supply : Ac Mains, Dc 12V Car Battery,Dry Cells (8Xum-1) , Dimension W200xh240xd145mm , Dionised Water 5 Ltr Cane(Each),Consumable , Disinfectant Renaclean Cold Sterilant (5 Ltr Can) , Disinfectant Renasteril Hot Disinfectant (5 Ltr Can) , Disposable Appronpvcconsumable Full Size , Disposable Bed Sheet 60X90 , Disposable Cresent Knife(2.2Mm),Consumable , Disposable Cup For Urine-Sputum 30Ml 80 To 90 Mm Diameter 100/Pkt , Disposable Dust Mask - Jl246c Equivalent To N-95 Mask , Disposable Examination Gloves Made Of Natural Rubber Latex, Pre-Powdered, Non-Streile Medium , Disposable Examination Gloves Made Of Natural Rubber Latex, Pre-Powdered, Non-Streile Small , Disposable Examination Gloves Made Of Natural Rubber Latex, Pre-Powdered, Non-Streile, Size:- Large , Disposable Keratom Knife(2.8Mm),Consumable , Disposable Keratom Knife(3.2Mm),Consumable , Disposable Needle, 24G Surgical Material , Disposable Needles 22Gconsumable , Disposable Needles 23 No , Disposable Needles 26G X 1/2Consumable , Disposable Paper Gloves Size 7 Inches Consumable , Disposable Paper Gloves Size 7,1/2 Inches Consumable , Disposable Pricking Lancet (Pkt Of 200 Units)(Packet),Consumable , Disposable Pricking Lancet 100 Unitsconsumable , Disposable Scalp Vein Set Size 20 No , Disposable Scalp Vein Set Size 22 No(Each),Consumable , Disposable Sharp Collection Containers 1.5 L , Disposable Sharp Collection Containers 5 Ltr , Disposable Sideport Knife(Num),Consumable , Disposable Spinal (L.P.) Needle(25G),Surgical Material , Disposable Spinal Needle 18 No. , Disposable Spinal Needle 22 No. , Disposable Spinal Needle 23 No. , Disposable Sterile Gloves B.I.S Specification Gloves, Surgical Rubber, Made Of Hypoallergic Latex 100%, Electronically Tested Sterilized 6 Inch / Pair(Pair),Surgical Material , Disposable Sterile Gloves B.I.S Specification Gloves, Surgical Rubber, Made Of Hypoallergic Latex 100%, Electronically Tested Sterilized 7 Inch / Pair , Disposable Sterile Gloves B.I.S Specification Gloves, Surgical Rubber, Made Of Hypoallergic Latex 100%, Electronically Tested Sterilized6.5 Inch / Pair(Pair),Consumable , Disposable Sterile Gloves Bis Specification Gloves, Surgical Rubber,Made Of Hypoallergic Latex 100%,Electronically Tested Sterilize No 7Inch/Pair(Pair),Consumable , Disposable Sterile Gloves Isi Marked Surgical Rubber Hypoallergenic Latex 100% Powder Free 7 1/2 Inc , Disposable Sterile Gloves Isi Marked Surgical Rubber Latex 100% Powder Free 6 Inches , Disposable Sterile Gloves Isi Marked Surgical Rubber Made Of Hypoallergenic Latex 100% Powder Free 7 Inches , Disposable Sterile Hypodermic Syringe 10Ml(Each),Consumable , Disposable Suction Catheter Assorted Covering All Sizes 10,12,14,16,18Consumable , Disposable Surgeon Cap(Box Of 100 Caps) , Disposable Syringe (For Vitamin K Inj)(1Ml With Needle 26G),Consumable , Disposable Syringe With Needle(20Ml Each),Needle , Disposable Syringe With Needle(2Ml Each),Syrings , Disposable Syringe With Needle(3Ml Each),Syrings , Disposable Syringe With Needle(5Ml Each),Needle , Disposable Three Layer Surgical Mask(Box Of 100 Mask) , Distilled Water (1X5 Lit),Consumable , Dialyzers Multiple Use Made Of Polysulphone Or Polyethersulfone Low/Middle Flux, Hi Performance Dialyser Performance Enhanced Technology With Hi Biocompatibility Housed In Medical Grade Polycarbonate Openable Ends For Easy Cleaning Caps(For Dialysate Inlet Utlet For Safer Storage Openable Caps(Red And Blue)Hi Quality Sterilisation Procedure Using Gamma Radiation And Should Meetings Standards Of European Ce/Iso13485:2003Sterlised),Consumable , Dj Stent For Ureter 6 Fr , Dj Stent For Ureter 8 Fr , Dm Water Pack Of 5 Litt Can , Domestic Hut 8.5 X 6 X 13 , Domestic Hut 8.5 X 6 X 13 , Door Matte Big Size Jooth (Sandard Quality) , Door Matte Big Size Plastic (Sandard Quality) , Door Matte Medium Jooth (Sandard Quality) , Door Matte Medium Plastic (Sandard Quality) , Double Blood Bag 450 Ml Cpda(Each),Consumable , Double Lumen Hoemodialysis Catheter With Pur Ext Tube , Double Lumen Polyurethane Cvp Catheter 4 To 5 Fr(Length 8 To 13 Cm, Each),Consumable , Dpx(1 X 250 Lit),Consumable , Dpx(1 X 250 Lit),Consumable , Drabkin Solution For Hb (1X5 Lit),Consumable , Drabkin Solution For Hb (1X5 Lit),Consumable , Draw Sheet Bleach 45 X 45 , Dressing Drum (Made Of Ss) (Size:-11X9) Standard Qualtiy , Dressing Drum (Made Of Ss) (Size:-9X9) Standard Qualtiy , Dressing Drum Ss Size 11X15 Standard Qualtiy , Dressing Drum Ss Size 6X6 Standard Qualtiy , Dressing Drum Ss Size 9X11 Standard Qualtiy , Dressing Trolley - Frame Work Made Of 1 Vertical M.S Pipe , Two S.S Shelves Over With S.S Railling On All Four Sides , The Trolley Fitted S.S Bucket And Bowl And Mounted On 4 Dia Castors.Over All Size 30Lx18Wx32H, Finish Pre Treated And Epoxy Powder Coated, Also Available In Complete S.S , Drop Bottle Plastic 500Ml , Droper 2Ml , Dura Patch (G.Patch)(10X12),Consumable , Dura Patch (G.Patch)(8X10),Consumable , Dustbin Foot Operated Plastic, Size 10Ltr, Isi Mark , Dustbin Without Foot Operated ,Size 5 Ltr,.Isi Mark , Dusting Powder, 10 Gm ( Neomycin Sulphate 5 Mg, Baccitracin 250 Unit, Sulphacetamide Sodium 60 Mg) , E.D.T.A. Vacunater With Needle(3 Ml),Consumable , Ea- 50 (Modified) (For Cytology)(1X125 Ml),Consumable , Ecg Paper (Chemical Coated)(80Mmx 20 Mtr Each),Consumable , Ecg Paper(Chemical Coated) 50Mm X 30 Mtr. Roll , Ecg Paper(Wax Coated) (50Mm X 30 Mtr, Roll),Consumable , Ecg Paper(Wax Coated) Heavy Quality 50Mm X 30 Mtr/ Roll , Economical & Compact , Edta K3 Vial Each , Edta Powder(250 Gm),Consumable , Edta Solutions K3 (150 Ml) , Edta Solutions K3 (500 Ml) , Edta Vial With Safty Cap (2Ml.) Capsule , Edta Vial With Safty Cap (2Ml.) Capsule , Ehrilichs Aidehyde Reagen (2X250 Ml),Consumable , Ehrilichs Aidehyde Reagen (2X250 Ml),Consumable , Electolyte Analyzer 3 P-Ise Based Technology Easy Selection Through Fuction Icon Of Key 100 Result Memory And Quality Contorol Option , Electric Geyser 10 Ltr Capacity Isi Marked , Electric Geyser 15 Ltr Capacity Isi Marked , Electric Led Troch Chargable , Electrolyte Solution A 250 Ml (250Ml) , Electrolyte Solution A 250Ml(250Ml),Consumable , Electronic Baby Weighing Machine Capacity 20Kg Resolution : 10 Gm Pan/Platform : 550Mmx300mm (Min) , Elisa Reader - 0.000-3.5 Abs Mesurent Range, 500 Test Programe & 10000 Result Store, Bichromatic Optic System With Plate Shaker, External Mouse For Easy Handing Large Touch Screen, Whole Plate Reading In Just 5 Sec , Elisa Reader & Washer Printer , Elisa Washer - 48 User Programmable Wash Protocoles, 8 Way/12 Way Manifold, Auto Calibration, Washes Flat Round & V-Bottom Well, Well Depth Detection , Emergency Cart , Emergency Drug Trolley/Crash Cart , Emergency Light Big Size , Empty Bottel 500Ml With Cap , Empty Bottle Droping 150 Ml , Endotracheal Tube Internal With Radioopaque Line(Dia 2.5 Mm To 5 Mm, Each),Consumable , Endotracheal Tube No 5.5(Uncuffed),Each , Endotracheal Tube No 6.0(Uncuffed),Each , Endotracheal Tube, Soft Cuff Towards The Distal End Kink Resistant Inflation Tube Murphy Eye At Distal End With Polished Smoothness Standard 15 Mm Connector Sterile, Single Use Curved Shaped Blister Pack-Suiting The Shape Of Product(Size 4 , Each),Tube , Endotracheal Tube,Soft Cuff Towards The Distal End Kink Resistant Inflation Tube Murphy Eye At Distal End With Polished Smoothness Standard 15 Mm Connector Sterile, Single Use Curved Shaped Blister Pack-Suiting The Shape Of Product(Size 3),Tube , Endotracheal Tubes Size 7 Cuffed Should Have Low Pressure High Volume Cuff And Radio Opaque Blue(25 Each),Consumable , Endotracheal Tubes Size 8 Cuffed Should Have Low Pressure High Volume Cuff And Radio Opaque Blue(25 Each),Consumable , Endotracheal Tubes Size 9 Cuffed Should Have Low Pressure High Volume Cuff And Radio Opaque Blue(25 Each),Consumable , Endotreheal Tube Size 4 Cuffed -Piece, Should Have Silicon Tube With Radio Opaque Blue Line , Enema 100 Ml (Sodium Acid Phosphate 10 Gm, Sodium Phosphate 8 Gm / 100 Ml) , Enema Appratus 1000 Ml Stainless Steel And Rubber Connection Tube Standard Qualtiy , Environmental Desontamintation System , Eosin 2% Solution (1X250 Ml),Consumable , Esbachs Reagent (125 Ml),Consumable , Ethanol (Abosolute Alcohol 99.9% (500Ml) , Eye Drape Disposable Towel (Size-70*70Cm Area 08*08),Consumable , Face Shield Protector Safaqi( ),Consumable , Factor Ix Deficient Plasma (Less Than 1%)(10X1 Ml),Consumable , Factor Vii Deficient Plasma ( Less Than 1%)(10X30 Ml),Consumable , Falcon Tube Plastic Contianers With Air Tight Cap , Fauchets Reagents (125 Ml),Consumable , Fdp Kit(4 Ml),Consumable , Feeding Tube (Catheter)(10 G, Each),Consumable , Female Reprodective System Complete , Femoral Catheters Single Lumen Set Adult(Size - 6F To 8F, Length 13 Cm To 15 Cm, Each),Consumable , Femoral Catheters Single Lumen Set Pediatric(Size - 3F To 4F, Length 13 Cm To 15 Cm Or Less),Consumable , Femoral Catheters Single Lumen Size Adult (Set Of 12 Different Sizes), Set , Femoral Catheters Single Lumen Size Size Pediatrics((Set Of 12 Different Sizes), Set),Consumable , Field Stain A 500Ml [5410005] , Field Stain B 500Ml [5410023] , Filter For Complete Pulmonary Function Testing (Including Dlco) With Body Box(100 Filters Per Pack, Consumable , Filter For Complete Pulmonary Function Testing (Including Dlco) With Body Box(100 Filters Per Pack, Make- Medisoft Sa),Consumable , Filter Paper No.1 Whatman , Filter Paper Sheet((Whatmann No 01) Pack Of 100 Sheets , Finish- Pre Treated And Epoxy Powder Coated , Finite Pump , Finite Pump , Fire Exjesting Cylander Abcd Type 5 Kg Complete , Fire Exjesting Cylander Refling For 5 Kg , Fistula 16G, Single Sterilizedsingle Needle Packing , Fistula 17G, Single Sterilizedsingle Needle Packing , Fistula Sterilized Twin Needle(16 G (Two Needle Pack)),Consumable , Fixer Powder (Bromex Acid Fixer With Hardner) ( 22.5 Ltr/Pkt) , Fixer: It Shall Be Powder Fixer To Produce Clean Radiographs Available In Pack Size Size:- 13.5 Ltr , Fixer: It Shall Be Powder Fixer To Produce Clean Radiographs Available In Pack Size Size:- 9 Ltr , Flask Glass Flat Bottam 1000Ml , Flask Glass Flat Bottam 500Ml , Flask Pyrex 500Ml , Flask White Glass Borosil 1000Ml , Flask White Glass Borosil 500Mg , Floor Cleaning 1000 Ml Isi Mark , Floor Cleaning Liquid Cleaning 5 Lit , Floride Vial With Sp Pack Of 100 , Flouride Solution (Pot.Oxalate 5% Flouride 1%) Pack Of 150Ml , Flow Regulator (Dial Flow)(Each),Consumable , Foetal Stethoscope Of Sk Sheal , Foldable Iol Sterile Lens Pc+14D(Lens-2),Pc+16D(Lens-3),Pc+18D(Lens-5),Pc+19D(Lens- 5),Pc+19.5D(Lens-5),Pc+20D(Lens-15),Pc+20.5(Lens-15),Pc+21D(Lens-13),Pc+21.5D(Lens- 11),Pc+22D(Lens-11),Pc+22.5D(Lens-5),Pc+23D(Lens-5),Pc+24D(Lens-3),Pc+26D(Lens-2)(100 Lens Per Box),Lens , Foleys Catheter Size 12-2 Way Consumable , Foleys Catheter Size 14-2 Way , Foleys Catheter Size 14-3 Way , Foleys Catheter Size 16-2 Way(11 Each),Consumable , Foleys Catheter Size 18- 2 Way , Foleys Catheter Size 20-2 Way(12 Each),Consumable , Foleys Catheter Size 22-2 Way(13 Each),Consumable , Foleys Catheter Size 24-2 Way(14 Each),Consumable , Foleys Urinary Catheter 2 Way Size 8 , Foleys Urinary Catheter 3 Way Size 16 , Foleys Urinary Catheter 3 Way Size 18 , Foleys Urinary Catheter 3 Way Size 20 , Foleys Urinary Catheter 3 Way Size 22 , Foleys Urinary Catheter Pediatrics Size 10 , Foleys Urinary Catheter Silkolatex 2 Way Sterile, Non Toxic Size 10 , Foleys Urinary Catheter Silkolatex 2 Way Sterile, Non Toxic Size 10 , Foleys Urinary Catheter Size 16 2 Way , Foleys Urinary Catheter(3 Way Size 12),Surgical Material , Foot Operated Sanitizer , Foot Sanitizer , Foot Step Double Steel Iron Standard Qualtiy , Forcepartery Sp Wells Cvd. 20 Cm/8” Standard Qualtiy , Forcepkocher Artery Cvd 8 “ Standard Qualtiy , Forcepkocher Artery Str 8 “ Standard Qualtiy , Forcep Allis Tissue 4 ?5Th20 Cm/8” Standard Qualtiy , Forcep Artery Mosquito Cvd 12.5Cm/5” Standard Qualtiy , Forcep Artery Sp Wells Cvd. 15 Cm/6” Standard Qualtiy , Forcep Dis Sectionplain Ss 17.5 Cm Standard Qualtiy , Forcep Dis Section Plain Ss 20 Cm Standard Qualtiy , Forcep Hysterectomystandard Qualtiy , Forcep Intestinalsize 16 Cm Standard Qualtiy , Forcep Intestinal Size 12.5 Cm Standard Qualtiy , Forcep Mousquito Str+Cvdsize: 12.5 Cm , Forceps Teeth Size 12.5 For Dressings.Steel , Forcepsplain Size 10 For Dressing S.Steel , Forcepsplain Size 12.5 For Dressings.Steel , Forcepsplain Size 17.5 For Dressings.Steel , Forcepsplain Size 25For Dressings.Steel , Forcepsteeth Size 10 For Dressings.Steel , Forcepsteeth Size 15 For Dressings.Steel , Forcepsteeth Size 25 For Dressings.Steel Standard Quality , Forceps Plain Size 15 For Dressings.Steel , Forceps Plain Size 20For Dressings.Steel , Forceps Teeth Size 17.5 For Dressing S.Steel , Forceps Teeth Size 20 For Dressings.Steel , Formaldehyde (Formalin)34% Acq 450 Ml Bottle , Formaldehyde 40% (Conc. Formaline)(1 X 30 Lit),Consumable , Formalin Chamber Internal Trays Sterdization Size 21X8X8.5Standard Quality , Formoline Solution 450Ml , Fouchets Reagent (100 Ml Bottle) , Fram Work Made Of Aluminum Tubes , Freedge 165 Litre , Freedge 220 Litre , Freq Resp.100-10 00Hz + 3Db , Full Bio Chemistry Analizer -200 Test/Hour, Staff Function, 60 Sample Positin With Refrigeration , On Board Wash Saction , 8 Interference Filters And 2 Position For Aptional, Photometric Range 0-3 Abs , Funnel , Funnel , G6pd Deficiency Test Kit - 10 Test , G-6Pdh (Quantitative Uv Kinetic (Liquistat Pack Of 15X1.1Ml (Span/ Tulip/ Erba) , Gauze Swab/Pad 4 Layer 10Cmx10cm , Gauze Swab/Pad 6 Layer 10 Cmx 10 Cm , Gauze Swab/Pad 6 Layer 20 Cmx 20Cm , Gentian Violet (Gram Stain) 100Ml Bottle , Giemsa Stain (Merck / Span) (125 Ml),Consumable , Glacial Acetic Acid (2.5 Liter),Consumable , Glass Beaker Cap.1000Ml , Glass Beaker Cap.500Ml , Glass Rod Size 12 Inch. , Glass Slide 75Mm X 25Mm 1.1 Mm [6120086] , Glass Slide 75Mm X 25Mm 1.35 Mm [987700] , Glass Slide With Isi Mark-At Least 75Mm X 25 Mm- Thickness At Least 1.1Mm,Detail Specifications-I-With Smooth Edges, Without Any Scrathtches. Ii-Glazed Glass.Iii-No Visual Or Chromatic Abbretions(50 Slides/Packet),Consumable , Glass Test Tube 12 X 100 (Medium Size) Heavy Quality 100/Pkt , Glass Test Tube 12 X 75(Small Size) Heavy Quality 100/Pkt , Glass Test Tube 5 Without Edge [987879] , Gloter Aldhiygde Solution Packge 1 Ltr , Gloves Latex Autoclavable 8 No (Pair) Made Of Natural Latex Micro Rough Finish For Better Grip , Gloy Size Board , Glucometer , Glucometer Cell , Glucometer Sprips (1X100) , Glucometer Strip (1X100) , Glucometer Strips 1 Should Be Able To Use Capillary Blood Samples 2 Should Have Expiry As Printed On The Label Of The Supplied Box(3 All Strips Should Have At Least One Year Expiry Date From The Date Of Supply 1 Glucometer Free With Each 1 Thousand Strips Rate Should Be Quoted For ,Consumable , Glucose600 Ml(Model Ba 400 System Consumable , Glucose Kit (God/Pod)(350Ml),Digonstic , Glutaraldehyde Solution 2% In 5 Litre Can (2 Strips/Vials Per Each Can)(5 Litre Can),Consumable [700591] , Gold Chloride (1X1 Gm),Consumable [710056] , Goods Carrying Vehicle. (Size 48X24X24) Four Wheeler , Gpt (Ast) Kinetic (Liquistat) Pack Of 10X10ml , Gram Iodine (Gram Stain) (100Ml Bottle)(Bottle),Consumable , Gram Iodine (Gram Stain) 125 Ml , Gram Staining Kit (Crystal)(125Ml X 4),Consumable , Grasper- Laparoscopic 5Mm Straight 360 Degree Rotating With Insulated Shaft, Toothed A Traumatic Grasper With Ratchet Mechanism, Plastic Grip(36 Cms Length, Independently Moving Jaws),Consumable [720068] , Gynec Sheet 80 X 48 Standard Pvc Quality , Gypsona 4” , Gypsona 6” , Haby Gum Boot , Haematoxyline Solution (Harris)(1X125 Ml),Consumable , Haemoglobi Pippate(Pippate),Consumable , Haemoglobin Tube(Tube),Consumable , Haemoglobino Meter (Sahilmathard) , Half Volume Pt And Aptt Testing , Hand Sanitizer With Pump(500Ml),Bottle , Hand Wash Liquid Cleaning Standard Company , Handpiece(Blue),Consumable , Handpiece(Transducer),Each , Hb Colour Scal Book , Hb Electrophoresis(200 Test),Consumable , Hba 1 C (Glycosylated Hb)(100 Tests),Consumable , Hba Ag Elisa 96 Kit 1X96(Each),Consumable , Hba Ag Rapid Card Test(Each),Consumable , Hbnc Kit Complete - , Hbs Antigeng Kit Card(Pack Of 10 Card Test With 10 Dropper, 1 Buffer Solution, 10 Pricking Lancet And 10 Alcohol Swab),Digonstic , Hbsaganigine Kit Card(Pack Of 10 Card Test With 10 Dropper, 1 Buffer Solution 10 Pricking Lancet And 10 Alcohol Swab) J Mitra/ Span/ Tulip , Hbv Elisa Test Kit Pack Size : 96 Wells Per Kit(Rate Should Be Quoted For 1Kit Containing 96 Wells),Consumable , Hbv Rapid Test Kit Quantity Is In No. Of Test Card Only(And Rate Should Be Quoted For One Test Card),Consumable , Hcl N/10 (500 Ml Bottle) , Hcv Kit Card Test(25 Test / Kit),Digonstic , Hcv Rapid Test Card Single Test (J Mitra/ Span/ Tulip) , Hdl Kit 50 Test [987882] , Hdl Kit Ppt(2X50ml 200 Test/Kit),Consumable [987760] , Hdl/Ldl Standard(1X1 Ml),Consumable [710063] , Hdpe Jar 5 Litt With Cap , Heamstrips (Oc , Hematology Cell Counter Reagents Dilutent (20 Ltr) , Hematology Cell Counter Reagents Rinse Solution (20 Ltr) , Hemoostasi Analyzer , Hemotocyto Meter,Consumable , Hiv 1&2 Test Cards , Hiv 1+2 (Rapid) Per Card (J Mitra/ Span/Tulip) , Hiv 1+2 (Rapid) Per Card J Mitra , Hiv Rapid Test Card Single Test (J Mitra/ Span/ Tulip) , Hospital Bed Ss With Mattress , Hot Air Oven 14X14X14 , Hot Water Bagstandard Company , House Hold Referigerator Double Door Isi 265 Litt , Hub Cutter- Non Electric Lockable Safety Portable Box For Disposal Of Hypodemic Needles.Consumable , Human Albumin 20%(50 Ml Vial Ffs Glass Bottle),Bottle , Hydrochlorid Acid(Hcl) N/10 (500 Ml Bottle) , Hydrogen Peroxide (Conc.) H2o2 (500 Ml),Consumable , I.V Stand 4 Legs Base , I.V. Cannula With Injection Valve(Size 24 G),Consumable , Ice Gel Pack (200&500Gm) , Id Wrist Band(Identification For Mother/Child Specific Colour)(Wrist Band/No),Consumable , Immersion Oil (Refractive Index Of 1.48. It Should Be Colourless,Odourless, Transparent, Free From Fluorescence In Day Light With Realtive Density Of 0.827 To 0.890, Visosity Of 110To Gravity Of 76-0.78 At 15.5 C , Immersion Oil Lens (All Type) , Incubater B.O.D , Incubator , Incubator Digital Microbiological , Indicator Sol, For Ph (Litmus Sol) (1X500 Ml = 500 Ml),Consumable , Infant Feeding Tube (Catheter) Size: 3G , Infant Feeding Tube (Catheter) Size: 4G , Infant Feeding Tube (Catheter) Size: 8G(Each),Consumable , Infant Feeding Tube Size: 5G , Infant Feeding Tube Size: 6G , Infant Feeding Tube(10 G Each Piece, Each),Consumable , Infant Feeding Tube(7G Each Piece, Each),Consumable , Infant Mucus Extractor Sterile Pvc(Each),Surgical Material , Infant Weing Scal With Bag , Infantometer , Infusion Pump Features :- Front Load Of Yringe , Automatic Detection Of Syring, Bolus And Purge Facilty , Self Illutrative Contorl Panel , Syring Capacity , 10Ml-300Ml/Hr.20Ml-500Ml/Hr , Input – Mic-1:3Mv, Mic-2:3Mv, Aux: 100Mv 800Mv Rec. Output 800Mv Tone Controls Bass : + 6Db At 80Hz, Treble :+ 6Db At 8Khz Power Req. 220-240V Ac 50/60Hz, 12V Car Battery 12V.3.5Ah Rechargeable Battery Dim/.Wt. W215xh285xd150 Mm/4.65Kg , Input Channels : Built –In Microphone , Instrument Tray Ss With Cover 10X8 Standard Company , Instrument Tray Ss With Cover 15X12 Standard Company , Instrument Trays With Cover Ss Size: 10 X 12 Standard Company , Instrument Trays With Cover Ss Size: 7 X 11 Standard Company , Instrument Wash 500Ml With Spray Pump , Insulated Container , Insulin Syringe(Each),Consumable , Intra Venous Set (Adult) With Airway And Needle Standard Company , Intra Venous Set (Child) With Airway And Needle Standard Company , Intracath Cannula For Single Use (Intravascular Catheters) Bis(Gauze 22, Length 25),Consumable , Inverter Battery 500 Watt 150 Ah Isi Mark , Inverter With Battery 1000 Va [One Battery Required]Isi Mark Standard Companywith Installation , Inverter With Battery 1500 Va [Two Battery Required]Isi Mark Standard Companywith Installation , Invertor Batteryisi Mark 150 Vah , Iol - Made By Repated Company, Eto Sterlized, Powernon Foldable Iol Sterile Lens Pc+14D (2), Pc+16D (3) Pc+18D (5), Pc+19.5D (5), Pc+20D (15), Pc+20.5D(15), Pc+21D (13), Pc+21.5D (10), Pc+22D (10), Pc+22.5D (5), Pc+23D(5), Pc+24D(3), Pc+26D (2), Ac+19D (2) (No), Single Price(Standard Company) , Iron Bed Size 5X2.6 , Iron Box 5’X2.5’X2.5’’ , Iron Box 6’X3’X3’’ , Iron Stand With Belding Work , Isoflurane(250 Ml Amber Color Bottle),Inhalation , Isopropyl Alcohol (Propanol)(1 X 2.5 Lit),Consumable , Iv Cannula Size With Inj.Valve (Port)(18G ), Consumable , Iv Cannula Size With Inj.Valve (Port)(22G ), Consumable , Iv Cannula With Inj Valve(18G),Consumable , Iv Cannula With Inj Valve(20G),Consumable , K Wire(Length 375Mm Size:1.6Mm Roll),Consumable , K Wire(Length 375Mm Size:1.8Mm Roll),Consumable , K3 Blood Vaccutainer Edta-100 Tubes/Pkt , Keratome 3.2 Keratome Round Stock 3.2Mm Full Handle Knives E.T.O. Sterile Angled Bevel Up 45 Deg( ),Consumable , Knife Blade All No Pack Of 100 , Kit For Total Protein (Including Albumin And Total Protein) 100Ml Bottle , Lab Coat , Labour Room Tray 12”X10” , Labour Room Tray 15”X12” , Labour Table 3 Fold Ss With Foam Mattress, , Labour Table Manul , L-Alanyl L-Glutamine Solution For Infusion (20%W/V)(Each),Consumable , Larrynoscope Set With Four Blades (Adult) , Larrynoscope Set With Four Blades (Infant) , Larrynoscope Set With Four Blades (Paediatric) , Latex Based Baloon Capacity (30-50Ml) Foleys Catheter(Size 14-3 Way),Consumable , Latex Based Baloon Capacity (30-50Ml) Foleys Catheter(Size 16- 2 Way Each),Consumable , Latex Based Baloon Capacity (30-50Ml) Foleys Catheter(Size 18- 2 Way, Each),Consumabl , Latex Based Baloon Capacity (3Ml) Foleys Urinary Catheter Peadiatrics(2 Way Size 8, Each),Consumable , Latex Based Baloon Capacity (3Ml) Foleys Urinary Catheter Peadiatrics(Size 10 , Each),Consumable , Latex Examination Gloves (Large) (100/Pkt)(Packet),Consumable , Latex Examination Gloves (Small) (100/Pkt)(Packet),Consumable , Latex Examination Gloves(Medium),Consumable , Lcd Projecter , Ldh Kit Pack (50 Ml Bottle),Consumable [700603] , Lead Letter 0-9 Sets (100 Clips/Pkt) , Leishman Stain (500 Ml Bottle),Consumable , Leishmann Stain Sol With Buffer Tablet Ph (1X5 Lit),Consumable , Lens Cleaning Paper , Lenstip(1 Each),Consumable , Lenstip(1 Each),Consumable , Life Boy Soap , Life Boy Soap 100Gm , Light Weight Composite Mesh : Polypropylene Andpolyglycolic Acid Partially Absorbable Composite Mesh With Large Pore Size 6 X 11 Cm , Liquid Hand Wash , Liquid Hand Wash Solution With Dispenser Consumable(500 Ml),Consumable , Liquid Paraffin 50Ml(Bottle ),Consumable , Liquid Senitzed (Hand Antiseptic) , Liquor Ammonia (500 Ml),Consumable , Long Body Suit -Non Woven Fabrie , Long Line Silicon Catheter, G-24, Fr-2, L-30Cm , Low-Profile Titenium Chemo Port With Cilicon Catheter (9.6 Fr, 6.6Fr, 3.9Fr,) Length -60Cm,Guide Wire, Peel-Away Desilet,Hubsite Needle(22G*20Mm) , Lugols Iodine Pack Of 100Ml , M-30-D-Diluent(20Ltr),Consumable , M-30-R-Rinse(20Ltr),Consumable , Macconckeys Agar(500Grm),Consumable , Macconckeys Agar(500Grm),Consumable , Mackintosh Double Colour Water Proof Rubber Marked Isi Hospital Rubber Sheeting Is:4135-1974 Packing And Making : As Per Clause No 4.1 And 4.3 / Mtr , Macro Porous Tissue Separating Multi Layered Partially Absorbablemesh With Oxidized Regenerated Cellulose, Polydioxanone And Soft Polypropylene Mesh(Size 15 Cm X 15 Cm),Consumable , Macro Porous Tissue Separating Multi Layered Partially Absorbablemesh With Oxidized Regenerated Cellulose, Polydioxanone And Soft Polypropylene Mesh(Size 15 Cm X 20 Cm),Consumabl , Malaria Antigen Pv/Pf Single Test , Malaria Rapid Stain Kit (Jsb I&Ii) One Minute Stain For Blood Parasite) Pack Of 2X500ml , Male Reprodective System Complete Standard Company , Malleable Splirls (X-Ray Through The Splints Fixing Of Splint Is By Zipper Or Belt Distal End Left Open To Expose Toes Should Be Washable And Reusable) , Mammanatallie Standard Company , Manometer And Flo Meter For Oxygen Cylinder , Maryland Dissector- Laparoscopic 5Mm Curved Maryland Dissector With Tapering End, 360 Degree Rotating With Insulated Shaft, Non Ratchet , Plastic Grip(36 Cms Length, Monopolar Pin Provision For Usage With Electro Surgical Unit, Independently Moving),Consumable , Masson Trichrome Staining Kits(100 Test),Consumable , Match Box , Mattres Cover Complete Size L.6.5Fxw3.5Fxt5.5F Inch , Mattress Coir With Foam Topping Plain Cloth Cover Size 72X36x4 Thik With Ragzine Cover , Medical Nitrous Oxide Gas In Jambo Size Cylinder(D Type),Miscellaneous , Medical Nitrous Oxide Gas In Medium Size Cylinder(B Type),Miscellaneous , Medical Nitrous Oxide Gas In Small Size Cylinder(A Type),Miscellaneous , Medical Oxygensteel /Aluminium Cylinder (10 Litres Water Cap) With Gas Specific Pin System(10 Liters),Inhalation , Medical Oxygen Gas Ip In Jambo Size Cylinder(D Type),Miscellaneous , Medical Oxygen Gas Ip In Medium Size Cylinder(B Type),Miscellaneous , Medical Oxygen Gas Ip In Small Size Cylinder(A Type),Miscellaneous , Medical X-Ray Film-Polyester Based Imaging Film 30.5 Cm X 30.5Cm (12X12) Size:- 50 Sheets In One Packet , Medical X-Ray Film-Polyester Based Imaging Film 35.6 Cm X 43.2Cm (14X17) Size:- 50 Sheets In One Packe , Medical X-Ray Film-Polyester Based Imaging Film 35.6Cm X 35.6Cm (14X14) Size:- 50 Sheets In One Packet , Medigard Hand Scrub [987893] , Messuring Cylinder 1Ltr With Spout , Mesuring Cylinder Pack Of 100Ml , Mesuring Cylinder Pack Of 1Lit With Spout , Mesuring Cylinder Pack Of 500Ml , Methanol(Acetone Free) For Leishman Staining (1X2.5Lit) , Methanol Pack Of 5Ltr , Methylaled Spirit , Methylate Spirit (Sep.Chemical Name Ethanol Denatured+5% Isopropyl Alcohol+5%Methanol, Molecular Structure : C2h50h Molecular Wt: 46.07 Purity : 90% , Methylene Blue 25Gm Dye Content 82% , Methylene Blue Pack Of 500Ml/Gram (Dye Content+42% Sepc.Chemical Name: Methylthionine Chloride, Chemical Structure: C16h18c1n3s,Molecular Wt: 319.9, Dye Content: Approx 82% (Should Be Available On The Container) , Metresses 3X6 With Raxine Cover 4 Densit , Micro Drip Set , Micro Pipet 1000 Fix And Variable Each , Micro Tips Big Pack Of 1000 Pices , Micro Tips Big Pack Of 500 Pices , Micro Volume Drip Set , Microalbumin Urine(100 Tests),Consumable , Micronthik Bag 10 Lit. , Micronthik Bag 30 Lit. , Micronthik Bag 5 Lit. , Micronthik Bag 50 Lit. , Micropiptte 100-1000 , Microscope With Digital Display And Having Magnification , Microsurgery Speciality Gloves(Size 6.5),Lens , Microtips (2-200 Ul) 1X1000(Each),Consumable , Milkiwhitegel Based Sanitizer1.Ethinol (Cas-64-17-5) 58-62% 2. Benzoil Coline Chloride 0.52% 1 % 3. Ph Neutral Contact Time 15 Sec 4.(Pack Size L& 500 Ml With Dispensor),Consumable , Mindray Bc 5300, Auto Hematology Analyzer Part -5(M- 53Diluent),Consumable , Mindray Bc 5300, Auto Hematology Analyzer Part -5(M- 53Leo (Ii) Lyes),Consumable , Mindray Bc 5300, Auto Hematology Analyzer Part -5(M- 53Lh Lyes),Consumable , Mixed Oxidant Disinefction Genration System , Mixi Isi Mark , Mobile Operatinglight Single Dom , Mobile Operating Light Double Dom , Mobile Operating Light Four Dom , Mobile Operating Light Three Dom , Modular Automitic Blood Culture System , Mopping Pad , Motorcycle Pa Amplifier Set (Mpa-40S) (Spc. Power Output16 W Rms At 10% Thd/22W Rms Max, , Motorized Ot Table With Chair For Ophthalmology , Mtp Cannulas Standard Company , Mva Kit (Mannual Vaccum Aspiration Kit) , Mva Kit (Mannual Vaccum Aspiration Kit) Consumable , N-95 3M Disposable Raspirator(Without Valve Ffp2),Consumable , N-95 3M Inv Disposable Raspirator(With Valve Ffp2),Consumable , Nah2 Po4 (Anhydrous) Analar / Gr/Ar (1X500 Gm = 500Gm),Consumable , Nasal Catheters Child Size Disposable Nasal Prongs , Nebulization Mask - Kit (Pediatrics) , Nebulization Mask-Kit (Adult) , Nebulize Compressor. Piston Model, Fitted With Small Fan, Nices Less 60 Decible, Nebulizer Chamber Autoclave, Particle Size Between 0.5 To 5 Micron Suitable For Adult And Pediatric Patient. Resptrable Particle Above 60, Tor 300 Mg/Min , Needle And Syringe Destroyer Electrically Operated , Needle And Syringe Destroyer Manually Operated , Needle Holder Laparoscopic 5Mm Straight Reusable Needle Holder With Ratchet Mechanism With High Quality Tungsten Plated Jaws For Enhanced Needle Grip(36 Cms Metal Shaft),Consumable , Needle Hypodermic Size 23 G , Needle Hypodermic Size 24G , Needle Hypodermic0insulin (Metallic Non0sterile) Needle , Neomycin And Sulfacetamide Sprinkling Powder 5 Gm(Each),Consumable , Neonatal Infant Weighing Scal With Sling , Neonatal Urine Collector Bag 50 Ml , Neubauers Chamber(Each),Consumable , Nibp (Non Invasive Blood Pressure) Multi Channel Monitor) , Nitrous Oxide Cyilnder , Non -Contact Rapid Temperature Measurment System-Screen 2.8 Inch Tft Screen, Infrared Resolution Size 160X120, Frame Rate 9Hz, Temperature Measurment Range 30 Dig.C-45Dig.C, Accuracy + 0.5Dig.C, Distance 1M. Measuring , Storage - Take And Store Photos To Sd Card , Software Pc Analysis Software, Battery - Rechargeable 3.7V/5000Mah Lithium Battery. 22650 Single Cell, Battery Working Hrs- Up To 6Hrs.To Escort Your Continucous Work, Weather Proof, Nycocard Reader -Up To 2M, Tripod Mounting Hole 1/4 Inch, Hba1c, Microabumin, D-Dimer, C-Reactive Proteins , Non -Invasive Ventilaor (Sponteneous And Timed) , Non Tuch Thermo Meter , Nuclear Stain Rapid Pap Pack Of 500Ml , Nutrient Agar(500 Grm),Consumable , Nylon Suture Spatulated Micropoint Reverse Cutting Needle, Double Armed Suture Size 9-0(12 Foils/Pkt),Suture , Obsteric Labour Talbe Mechacally :- Sep- Frame Work Made Of Heavy Ms Crca Tubular Pipe.Stainless Steel Top In Two Section , Back Rest Section Adjustable On Retched System, Trendleburg Position Adjustable On Screw Mechanism By Handle. Supplied With Waste Collecting , S.S Bowl On S.S Bracket And I.V Rod , Height Adjustable A Pair Of Leg Holders With Straps, Complete With Self Locking Traction Handle I.V Rod , Overall Size 72 Lx27Wx30H Cms.Finish Pre Treated And Epoxy Powder Coated.Also Available In Complete S.S , Occult Blood Test Kit (Haem Test Kit) (1 X 100 Strips),Consumable , Og6 (For Cytology)(1X125 Ml),Consumable , Operating Microscope For Ent (Imported) , Ophthalmo Scope Direct , Ophthalmo Scope In Direct , Orthopaedic Speciality Gloves(Size 7),Consumable , Orthopaedic Speciality Gloves(Size 7),Consumable , Overall Size 48Lx24Wx24H , Oxalic Acid , Oxidisedcellulose Absorbable Hemostate( 2X3),Consumable , Oxidisedcellulose Absorbable Hemostate(2X14),Consumable , Oxidisedcellulose Absorbable Hemostate(4X8),Consumable , Oxidised Regenerated Cellulose Absorbable Hemostate(1X2),Consumable , Oxidised Regenerated Cellulose Absorbable Hemostate(2X4),Consumable , Oxidised Regenerated Cellulose Absorbable Hemostate(4*4),Consumable , Oxygen Conentrator , Oxygen Cylinder (It Should Be A Standard ‘J’ Type Molybdenum Steel Cylinder To Fill Medical Oxygen The Capacity Should Be Of 5000 To 6000 Liters (5To6m3) At A Pressure Of 1800-2000Ibs/Inch2, A Pressure Regulator Capable Of Reducing The Pressure To Appropriate Level To Run Either A Ventilator Or Provide Oxygen Therapy With A Flow Meter Should Be Provided , Oxygen Cylinder Flow Meter , Oxygen Cylinder Gauze-1 , Oxygen Cylinder Gauze-2 , Oxygen Cylinder Gawge Valum , Oxygen Cylinder Jumbo Size Complete Set , Oxygen Cylinder With Instrument Set For Oxygen Delivery B Type,Make-Everest Kanto Cylinder Limited;(Model- Everest;Country Of Origin-India),Consumable [75001] , Oxygen Cylinder With Instrument Set For Oxygen Delivery D Type,Make-Everest Kanto Cylinder Limited;(Model- Everest;Country Of Origin-India),Consumable [75002] , Oxygen Humidifier , Oxygen Inhelation Mddial Oxygen Steel Aluminium Cylinder 10 Ltr( ),Consumable , Oxygen Mask Adult (Standard Size) Standarad Company , Oxygen Mask Paediatric (Standard Size) Standarad Company , Oxygen Nasal Cannula(Neonatal),Consumable , Oxygen Nasal Canula (Neonatal) 7 White Colour Tubing And Threaded Nut(25 Pcs/Pkt),Consumable , P.P.T 1.5 Tu Tubercullin Vial 5 Ml , P.P.T 10 Tu Tubercullin Vial 5 Ml , P.P.T 2 Tu Tubercullin Vial 5 Ml , P.P.T 5 Tu Tubercullin Vial 5 Ml , Paediatric - Double Lumen Catheter Set 6.5 F - 8.5 Fr, 13Cm (Curved), Kit , Paediatric - Double Lumen Catheter Set 6.5 F - 8.5 Fr, 13Cm (Straight), Set , Paediatric Drip Set(Set),Digonstic , Paediatric Epidural Set(19G Needle, Metal Stylet,22G Catheter,0.22Micron Epidural Catheter Lor Syringe , Paper Adhesive Microporous Surgical Tape 3 Inch X 5 M / Roll (10 Roll/Pkt)(3 Inch X 5 M / Roll (10 Roll/Pkt)),Consumable , Paper Adhesive Plaster 1 X 9.0Mts , Paper Adhesive Plaster 1/2 X 9.0Mts , Paper Adhesive Plaster Microporous Surgical Tape 1 Inch X 9 M / Roll , Paper Adhesive Plaster Microporous Surgical Tape 2 Inch X 5M /Roll , Paper Adhesive Plaster Microporous Surgical Tape 4 Inch X 9 M / Roll , Paper Adhesive Plaster Microporous Surgical Tape 6 Inch X 10 M / Roll , Paper Adhesive Plaster Microporous Surgical Tape 6 Inch X 5M /Roll , Para Film Sealing Film (Parafilm 100Mm Widht, 58M Length, For Use Between 40 Dgree C To 50Dgree C , Paraffin Strips , Patch Buprenorphine(10Mcg),Consumable , Patch Buprenorphine(20Mcg),Consumable , Patented Ball Method Technology For Extermely Reproducible And Realiable Result , Patented Ball Method Technology For Extermely Reproducible And Realiable Result , Patient Bed Powder Coted Size 84Lx36Wx24H , Patient Gown Standard Size , Patient Stool , Paracaine Eye Drop , Pediatric Chamber Set 100 Ml , Peledi , Ph Meter Digital For Water , Phenol Crystal 500Ml Purity 99.5% , Phenyal 40% /Phanolic Solution 40% , Phenyl - As Per Schedule O (Grade 1) 10 Lt Jar(Isi Marked),Consumable , Phenyl 40% , Photo Therapi Unit Double Surface , Photo Therapi Unit Single Surface , Pipete Graduated 0.2Ml , Pipett Graduated 2.0 Ml To 10Ml , Pistol Grip Curved Coagulating Shears With Ergonomic Handle In The Following Shaft Lengths 23 Cm. Can Seal Blood Vessels Upto And Including(5Mm In Diameter),Consumable , Pistol Grip Curved Coagulating Shears With Ergonomic Handle In The(Folloeing Shaft Lengths 36 Cm Can Seal Blood Vessels Upto And Including 5 Mm In Diameter),Consumable , Plain Disposable Vial 3Ml(Each),Consumable , Plain Vial With Screw Cap (12X75),Consumable , Plain Vial With Screw Cap(12 X 75),Consumable , Plaster Of Paris Bandage 10 Cm X 2.7 Mtr / Roll(Roll),Bandage , Plaster Of Paris Bandage Bp 10 Cm X 2.7 Mts/Roll Standard Company , Plaster Of Paris Bandage Bp 15 Cm X 2.7 Mts/Roll Standard Company , Plaster Of Paris Pack Of 5Kg , Plastic Bottle(300Ml),Consumab Empty With Cap , Plastic Bottle(500 Ml),Consumable Empty With Cap , Plastic Box 9X3.5’X3’’ , Plastic Box 9X6’X6’’ , Plastic Box Supirior Quality 10X7x4 , Plastic Box Supirior Quality 9X6x4 , Plastic Bucket Black 20 Ltr , Plastic Container With 2Lt Cap , Plastic Tanki 500 Ltr. For Water (3 Layerd, Standard Quality, Manu.By Reputed Company) , Plastic Thaila 18 Lengthx 16 Widex 8 Thickness , Platelet Dilution Fluid (100 Ml Bottle) [700193] , Poliglactinsuture1-90Cm (Vicryl) , Poliglactin Suture1-110Cm (Vicryl) , Poly Bag Black 16X18’’ , Poly Propylene Mono Filament Sterile Precut With 1/2 Cir Rb(Needle 30 Mm Length 70 Cm Non Absorbable Surgical Sutures Usp Size 1/0),Surgical Material , Polycarbonate Goggle- Material Plastic(Uv-Protection, Lens Thickness 1-2 Mm, Weight-40-50G),Consumable , Polyethylene High Pressure Extension Tube, Length - 100Cm , Polyethylene High Pressure Extension Tube, Length - 150Cm , Polyethylene High Pressure Extension Tube, Length - 200Cm , Polyglactin 30 Mm 1/2 Circle Round Body 90 Cm Size 1/0(12 Foils/ Pkt),Consumable , Polyglyconic Suture 110 Cm Vicryl No.2-0 Pack Of 12 Foils , Polyglyconic Suture 190 Cm Vicryl No.1 Pack Of 12 Foils , Polyglyconic Suture 190 Cm Vicryl No.1-0 Pack Of 12 Foils , Polypropylene Size - 1, (12 Foils/Pkt)(1/2 Cir Rb Needle 45 Mm, Length 90 Cm ),Needle , Polypropylene Size-2/0 (12 Foils/Pkt)(1/2 Cir Rb Needle 25Mm, Length 45 Cm),Needle , Polythine Whit Standard Quality(Weghting Capicty 500Gm To 20Kg) , Poocha Long Cloth Standar Size , Popete Stand Glass Large Size , Post Operative Bag With Window Size 100 Mm(1 Each),Consumable , Post Operative Bag With Window Size 70 Mm(1 Each),Consumable , Postmartem Gloves , Postmartem Set , Potassium Permanaganate , Powder Developer Suitable For Processing Medical X-Ray Films. One Developer Box Shall Contain Part A And Part B Which Are Mixed At The Time Of Preparation Of Solution Of Specific Capacity Size:- 13.5 Ltr , Powder Developer Suitable For Processing Medical X-Ray Films. One Developer Box Shall Contain Part A And Part B Which Are Mixed At The Time Of Preparation Of Solution Of Specific Capacity Size:- 9.0 Ltr , Ppe (Personal Protective Equipment)(Full Body Suit With Shoe Cover Free Size, Gloves, Face Sheeled, Goggle Consumable , Ppe Kit Consumable , Pregnancy Detection Kit Ce Marked/Isi Marked 30 Test/ Kit , Pregnancy Test Card For Urine Test Single Cared , Pregnancy Test Card(10 Card Pack,Consumable , Pregnancy Test Strips For Urine Pack Of 100 Strips , Pregnant Stage And Reprodective Dumy , Presure Cukker 05Lrt , Presure Cukker 07Rt , Presure Cukker 10Lrt , Prinking Needle Pack Of 100 Pices , Prinking Needle Pack Of 200 Pices , Procedure Table , Protable Pa Amplifier Systems Wa 620 Dpr 25 Watts (Power Output 25 W Max Input – Mic-1:3Mv, Mic- 2:3Mv, Aux: 100Mv 800Mv Rec. Output 800Mv Tone Controls Bass : + 6Db At 80Hz, Treble :+ 6Db At 8Khz Power Req. 220-240V Ac 50/60Hz, 12V Car Battery 12V.3.5Ah Rechargeable Battery , Protable Pa Amplifier Systems Wa 625Dpr 25 Watts (Power Output 25 W Max , Protection Suit And Gloves( ),Consumable , Protein (Total) 600 Ml(Model Ba 400 System Consumable , Protein Electrophorosis In Blood (Serum) ,Urine ,Csf(200 Test),Consumable , Protien& Albumine (Total) Biuret And Bcg , Protien (Urine) Ba 400 Biosystems Diagnostics Pvt Ltd(240 Ml),Consumable , Pt Kit (Time) (Ist 1.00 - 1.20)(2X4 Ml),Consumable , Ptah Staining Kits(100 Test),Consumable , Public Addressing System , Pulse Oximeter Finger Tip , Pulse Oximeter Table Top , Purified /Distilled Water- Laboratory Grade , Pyrethrum Extract 2%(25 Litre Drum) , Quick Diff Staining Kits For Pap Smear(100 Test),Consumable , Ra Factor 50 Test Kit Qualicative [987764] , Rapid Ra 25 Test , Rbc Dialuation Fluid (500 Ml Bottle),Consumable , Reaction Rotor 10 Pc(Model Ba 400 System Consumable , Reagent Bottel Glass 5Lit , Reagent For Hdl Cholestrol Test(100 Ml (4 X 25)),Consumable , Refling Oxygen Cylande Jumbo Large , Refling Oxygen Cylander Medium , Refling Oxygen Cylander Small A Type , Refrigerant Compressor (Copeland Usa Maneurop ) , Refrigeratedwater Bath , Refrigerated Chillers With Cooling Tank System (2 Tr, Air Cooled Water Chiller) , Reseant Bottle 1000Ml Empty , Reseant Bottle 500Ml Empty , Resusciatation Set With Infant & Neonatal Mask , Retinoscope , Revolving Computer Chair , Revolving Stool 4 Leg , Ria Vail 12X75mm Pack Of 100 , Rib Belt Large(Mfg By - Precious Life Care),Each , Rib Belt Medium(Mfg By - Precious Life Care),Each , Rib Belt Small(Mfg By - Precious Life Care),Each , Rna Extraction Kit - Icmr Certified Kit(250 Test),Consumable , Rolled Bandage 7.5Cm Ͻ 5M , Rolled Bandaze 10 Cm X 5 Mtr. , Rolled Bandaze 15 Cm X 5 Mtr. , Rolled Bandaze 5 Cm X 5 Mtr. , Rolled Bandaze 7.5 Cm X 5 Mtr. , Room Coolersize-21X19X36Isi Mark 16 Fan & Pump With Gi Sheet Body , Room Heater Hot Air Blower 2 Kw , Rpr Rapid Card Test Kit (50 Test/Pkt) , Rpr Test Kit(100 Test),Kit , Rpr Test Kit(100 Test),Kit , Rubber Bands All Assorted Sizes , Ryles Tube (Pvc) Size : Adult16-18 ) , Ryles Tube (Pvc) Size : Children: 10-12 , Ryles Tube(Size 14 Each Piece),Consumable , S Direct Billirubin(1000 Ml),Consumable , Salt Testing Kit(As Per Attached Specification , Kit),Consumable , Sanitary Napkins ,Consumable , Scessior Stainless Steel 8: , Scessior Stainless Steel 9: , Schiotz Tonometer , Schirmer Strip For Ophthalmic Use , Scissor Dressing Str/Cur Ss 12.5 Cm , Scissor Dressing Str/Cur Ss 15 Cm , Scissor Dressing Str/Cur Ss 17.5 Cm , Scissor Mayo Str/Cur Ss 16 Cm , Scissor With Round Trap , Scissors Mayo Fine. Cvs 16.5 Cm/6.5” , Scissors Mayo Fine. Str 16.5 Cm/6.5” , Scissors Str + Cvd Size 10 Cm Cutical , Seenk Jhadoo (Standard Size) , Self Adhesive Drainable Stoma Bag For Colostomy & Illeostomyâ - Double Layered Self Adhesive With Flex Patern, Transparent Drainable Stoma Bag With Built In Filter And Velcro Outlet(Size 76 Mm),Consumable 1-Pc , Seman Diluting Fluid 100 Ml. , Semi Auto Analyzer Ce Certified Minimum 1 Year Free Service Warrenty Remi/Erba/ Ranbaxy , Sencer Senitizer , Senior Executive Chair Foam With Leather Standard Company , Senstivity Disk , Serological Water Bath With Digital Temprature Display Size 605X300x150mm , Serum Amylase(100 Ml),Consumable , Serum Creatinine (100 Ml Bottle (2 X 50 Ml))(Consumable),Consumable , Serum Electrolite Na+ K+ Kit Analizer(50 Test Per Kit),Consumable , Serum T3 Kit, Elisa(96 Test Kit Each),Consumable , Serum T4 Kit, Elisa(96 Test Kit Each),Consumable , Serum Tsh Kit, Elisa(96 / Pkt),Consumable , Sessior 8 Inch Steal , Sevoflurane 20Cc(Each),Consumable , Sgot Kit (Kinetic) 5X20ml 200 Test/Kit , Sgot(25 Ml),Consumable , Sgpt Kit Lyphozyme 5X20 Ml , Sgpt Test Kit Reagent , Sgpt(100 Ml (4 X 25)),Consumable , Shadowlessceiling Light: 28 Dome With Seven Reflector Each Fitted With A Halogen Bulbe And Spherical Filter Glass Ensuring Shadow Free Corrected And Cool Light With A High Intensity Of Illumination (Major Ligh Of 1,20,000 Lux And Satelite Of 75000 Lux , Shadowless Lamp Microsope , Shallis Hemoglobinometer , Sics Blade-Cresent(15 Degree),Consumable , Sics Blade-Sideport(Sideport Entry Knife),Consumable , Silent Disel Generator 15Kvax12kv Dg Set , Silent Disel Generator 20Kvax16kv Dg Set , Siliver Foil , Silk No 1 Cutting Needle 1X12(1X12),Consumable , Simcoe I/A Cannula,Direct,(Num),Consumable , Single Umbilical Catheter With Leur Lock(Fr-3 To Fr 3.5 , L-40 Cm),Consumable , Single Umbilical Catheter With Luer Lock Stopcock Fr-2, L-40 Cm , Single Umbilical Catheter With Luer Lock Stopcock Fr-3, L-40 Cm , Single Umbilical Catheter With Luer Lock Stopcock Fr-4, L-40 Cm , Single Umbilical Catheter With Luer Lock Stopcock Fr-5, L-40 Cm , Slide Box Plastic Cap 100 Slide , Slide Box Plastic Cap 50 Slide , Slide Box Wooden Cap 50 Slide , Slide Holder (Made For Metal) , Slide Rack (Metal) For 25 Slides , Slide Stain Horigontal Cap 50 Slide , Slide Stain Vertical Cap 50 Slide , Slides For Microscopes. (Sep.Glass Slides Plain Size = 76Mmx26mmx1.3Mm, Clean, Scratch Free With Smooth Edges, Uniform Refractive Index, Pack Of 50 , Slit Lamp With Stand , Snellens Vision Box Roted , Sodium Citrate 3.8% - 500 Ml , Sodium Hydroxide (Naoh) (Analar / Gr/Ar) (1X500 Gm = 500Gm),Consumable , Sodium Hypochlorite 5% Solution(5 Ltr),Solution , Sodium Hypochlorite Solution 100 Ml Bottle , Sodium Hypochlorite(0.03 5 Ltr),Solution , Sodium Metabisuiphite (Na2s2o3) (Analar (Gr/Ar) (1X500 Gm = 500Gm),Consumable [710044] , Sodium Nitroprusside (100 Gm),Consumable [710034] , Sodium Pottassium Pack Of 500Ml , Soft Board 3X4 With Cover , Soft Board 4X5 With Cover , Soft Roll 4” , Soft Roll 6” , Solar Home Light System With Structure (Mne) Specification 2 Noof Cfl Rating 12V 40 Ah 7W Battery Capacity , Solar Inverter 850 Kva. Double Bettery Syestem. , Solar Led Street Lightning System Along With Mounting Pole , Spaculam , Speaker Output4 Voicecoll) , Spectra Optia Platelet Kit, Model : 10400(Packing Size : 6 Kits),Consumable , Sphygmomaw Meter , Spinal (L.P.) Needle Disposable 24Gconsumable , Spinal (L.P.) Needle Disposable 26Gconsumable , Spinal Needle G-22 L-120 Mm*0.71/Piece , Spinal Needle G-23 With Metal Stylet. , Spinal Needle G-27 L-120 Mm*0.40/Piece , Spine Board (Should Be In Plastic Material At High Strength And Waterproof. It Should Be 4 Rules For The Quick And Total Fixing Of The Head Immobilizer And Two Cavities Waherthe Board Lays On The Floor.When The Base Is Blocked In The Traditional Way, That Allow A Avoid Damaes Of Rip-Off Straps During The Usage Of Accommodation In The Ambulance It Should Be Handles For The Transport, Supplied With 3 Belts With Rapit Unhooking Buckle Should Have Maximum Radio Transparemcy To Make Exams Without Compromise Patient Condition.) , Spoon , Spring Balance Capacity 15 Kgs (For Baby Weighing) , Sprit Lamp (Steel) , Sputum Cup With Caps Pack Of 100Ml , Spuum Containersep.(Cups Made Of Special Medical Grade Polypropylene, Thin Plastc, Transulucent, Diameter- 4Cm,Capacity-30Ml, Srewable Cap Should Also Be Made Of Special Medical Grade Polypropylene And Should Be Air Tight. Leak Proof. , Stain (1X25 Gm = 25 Gm),Consumable , Stainic Rack(Each),Consumable , Staining Kit Reticulin(100 Test),Consumable , Staining Rod Steel (60Cm) , Stainless Steel Wire 30G , Steam Stock System & Mositure Trap , Steel Troch With 3 Cell , Sterilant Cold Disinfectant For Dialysis Containing Peracetic Acid Hydrogen Peroxide Acetic Acid(5 Ltr Can),Consumable , Sterilant Hot Disinfectant For Dialysis Containing 21% (Approx) Citric Acid, Malic Acid, Lactic Acid(5 Ltr Can),Consumable , Sterile Hypodermic Syring With Needle 20 Ml , Sterile Hypodermic Syring With Needle(5 Ml),Syrings , Sterile Hypodermic Syring With Needle, Mfg By Ph Health Care Pvt Ltd(10Ml),Consumable , Sterlium 500 Ml , Sterlizer Electrically Operated (Size 10X5X3) Isi Marked , Sterlizer Electrically Operated (Size 12X6X4) Isi Marked , Sterlizer Electrically Operated (Size 8X5X3) Isi Marked , Sterlizer Electrically Operated With Automatic Cut Off Ss 12X6X4 , Sterlizer Electrically Operated With Automatic Cut Off Ss 20X6X4 , Stethescope Super Quality , Stethoscope Litman Type , Stop Wathc Digital , Strecher Folding , Stretcher Trolley 4 Wheel 79X24X30 Without Handle , Stretcher Trolley 6 Wheel 79X24X30 Without Handle , Strip For Albumin Urine And Suger , Strip For Malaria Antigen, P Vivex, P Falciparum (50 Tests) , Suction Machine Portable , Suction Catheter Assorted 10 No/Each , Suction Catheter Assorted 9 No/Each , Suction Catheter, Sterile(Size Fg 20 (Disposable, Sterile Each)),Consumable , Suction Catheter, Sterile(Size Fg 22 (Disposable, Sterile Each)),Consumable , Suction Catheter, Sterile(Size Fg 6 (Disposable, Sterile Each)),Consumable , Suction Derice Apparatus , Sugar Albumin Strip , Sulfolyser For 5-Part Hematology Analyser All Model (Pack Size 5000 Ml),Consumable , Sulfur Powder , Sulphosalicylic Acid 3% W/V Pack Of 500Ml , Sulphuric Acid ( H2so4, Molecular Wt.98.08, Minimum Assay: 98% Colour: Clear , Sumag( ),Cream , Surface And Fogging Disinfectant Stabilised H202,10-11%W/V With Diluted Silver Nitrate Sol. 0.01%W/V(5 Litre Can),Each , Surface And Fogging Disinfectant Stabilised H202,10-11%W/V With Diluted Silver Nitrate Sol. 0.01%W/V(5 Litre Can),Each , Surface Disinfectant 10 Minute Aldehyde Free Disinfectant Containing Potassium Mono Per Sulphate Powder((5Kg Packet)),Powder , Surface Disinfectant 10 Minute Aldehyde Free Disinfectant Containing Potassium Mono Per Sulphate Powder((5Kg Packet)),Powder , Surgical Blade Isi Marked, Size 11(100 Per Packet),Surgical Material , Surgical Blade Isi Marked, Size 15(100/Pkt),Surgical Material , Surgical Blade Isi Marked, Size 22(100/Pkt),Surgical Material , Surgical Blade Isi Marked, Size 23(100/Pkt),Surgical Material , Surgical Blade Isi Marked, Size 24(100/Pkt),Surgical Material , Surgical Spirit(100Ml),99.9 %Bottle , Surgical Spirit(100Ml),Bottle , Surgical Spirit(450 Ml 99.5 %,Consumable , Surical Alumenium Waking Stick , Suter(8/0 (01 Box)),Consumable Pack Of 12 Foils , Suture Needle , Suture Needles Curved 1/2 Circle Round Bodyassorted Size 11-15 , Suture Needles Curved 1/2 Circle Round Bodyassorted Size 1-5 , Suture Needles Curved 1/2 Circle Round Bodyassorted Size 16-20 , Synthetic Absorbable Suture 1 With 1/2 Circle Taper Cut Needle (H) Size :1 40Mm Length 90Cm Polyglycolic Acid (Pga) (12 Foils Per Pkt) , Synthetic Absorbable Suture 2/0 With 1/2 Cir Rb Needle Size:2/0 30Mm Length 90Cm-Polyglycolic Acid (Pga) 12 Foils / Pkt , Synthetic Absorbable Suture 2/0 With 1/2 Cir Rb Needle Size:2/0 40Mm Length 90Cm-Polyglycolic Acid (Pga) Pack Of 12 Foils , Synthetic Absorbable Suture 3/0 With 1/2 Cir Cutting Needle Size:3/0 36Mm Length 70Cm -Polyglycolic Acid(Pga) 12 Foils / Pkt , Synthetic Absorbable Suture 3/0 With 1/2 Cir Rb Needle Size:3/0 20Mm Length 70Cm-Polyglycolic Acid (Pga) Pack Of 12 Pc , Synthetic Absorbable Suture 3/0 With 1/2 Cir Rb Needle Size:3/0,40Mm Length 90Cm-Polyglycolic Acid (Pga) Pack Of 12 Pc , Syring Needle Distroyer Electric Standard Company , Syring Needle Distroyer Menualstandard Company , System For Delivering Saturated Atomized Steam For Decontamination Of Surfaces , Tasla Iron Standard Size , Test Tube 12 X 100 (Medicm Size) 100/Pkt , Test Tube 12 X 75 (Small Size) 100/Pkt(12 X 75 (Small Size) 100/Pkt),Tube , Test Tube 15X125 [987819] , Test Tube Medium (12X100) 100Eack/Pkt(Each),Consumable , Thema Col Box (25Cmx21cm) , Thematic Apperception Test With Cards And Manual , Therma Coal Box(Size 9X6x6) , Thermometer Guaze With Automatic Display , Thermometer Manually For Fever Tamprature , Three Layer Surgical Mask Pack Of 100Pc , Thrombin Time Kit(10X3 Ml),Consumable , Thyroxine(T3),Pack Of 96Test , Thyroxine(T4),Pack Of 96Test , Thread Real For Suture Cotton , Tips For Auto Pippetes 10 To 100 Micro Litres , Tissue Paper Roll(Each),Consumable , Tissue Roll Paper (13Cm) , Tmt Graph Paper A4 Size, 100 Piece/Pkt , Toilet Brush Super Quality , Tooke Corneal Knife(Num),Consumable , Torch 3Cell Steel Body , Torch With Cells , Torch With Three Cell Isi Market Medium , Torch With Two Cell Isi Market Medium , Total Protein (100 Ml),Consumable , Total Protein Lysozyme 1X50 Ml , Total Protein Test Kit(100 Ml Bottle),Consumable , Tourniquet With Belt(Mfg By Precious Life Care Pvt Ltd)(Good Quality Pairs),Consumable , Towel Mayo Forcep Size 8 To 15 , Triglycerides (Enz.End Point) Liquisat) Pack Of 10X10ml , Trolley For Patient Ss , Tsh (Elisa) Pack Of 96Test , Tube Sealer Electric , Tuberculin Syringe , Two Step Slit Lamp , Typhoid Test Card Single Test For Widdal , Tyvek Suit Kit - 1 Pcs Full Body Cover, 1 Pcs 3Layer Mask, 1Pcs Gloves, 1 Pair Shoe Cover, 1 Pair Of Goggles(60 Gsm Non Wooven Fabric),Consumable , Uero Bag 2Letrs Capacity , Umbical Cord Clamps- Plastic Material (Box Of 100 Clamps) Consumable , Urea (Liqustat) Pack Of 10X10ml , Uric Acid (End Point) Pack Of 10X10ml , Urinary Drainage Bag (Paediatric)(100 Ml / Pc, Each),Consumable , Urinary Drainage Bag 2 Litre Cap With Non Return Valve (Eo Sterile) , Urinary Drainage Bag Cap With Non Return Valve (Eo Sterile)(2 Litre, Each),Consumabl , Urine Caontainer Sterile 30Ml Pack Of 100 , Urine Container 5Ml Disposable (50 Per Pkt) , Urine Container Size Of The Container Shall Be 30Ml Disposable (50 Per Pkt),Consumable , Uristic For Albumin/Suger Urine Pack Of 100 Strips , Urosticks(50/Pkt),Consumable , Utility Gloves , V.P Shunt Medium Pressure (Venticular Peritonial Shunt, (Venticular Catheter 15Cm Length, 1 Distilled Catheter 75 L, Struit Stylet)(Each),Consumable , V.P.Shunt(Low Pressur),Consumable , V.P.Shunt(Medium Pressur),Consumable , Vaginal Speculam Sims , Vaginal Speculam Ss Cusco Large , Vaginal Speculam Ss Cusco Medium , Vaginal Speculam Ss Cusco Small , Vaseline White/Yellow(1/2 Kg),Consumable , Vdrl (Rpr) 1X100 Sd Strip For Syphlis , Vdrl Kit (Strip) 50 Test/Kit),Consumabl , Ventilator Neoatal & Pediatric - Volume Cycle Ventilator, Microprocessor Based Assisted Controled Short Term For Prolonged Ventilation Can Be Provide, Volume Delivery 20 Ml To 2000 Ml Cmv, Simv, Asb, Peep, Cpap Modes Easy To Handle And Operational, Electrically Operated, Air Compresson Should Be Provided Along With The Ventilator Miounted On Same Trolley, Nebulizer & Humidifier Both Adult And Pediatric, Ups System And/ Or Battary Backup For Compressor And Ventilator, Adult, Pediatric And Neonatal Breating Cicuits (Each) Alarms Display Facillity, Fio2 Dispaly Digital Display- All Set Parameter Should Be Display Automatically , Vineland Adaptive Behavior Scale (Indian Adaption) With Manual , Viscoelastic Material - Made By Reputed Company Guaranted Eto Sterlized, Prefilled Glass Syring 2Ml , Viscoelastic Material - Made By Reputed Company Guaranted Eto Sterlized, Prefilled Glass Syring 3Ml , Viscoelastic Material - Made By Reputed Company Guaranted Eto Sterlized, Prefilled Glass Syring 5Ml , Viscoelastic Material - Made By Reputed Company Guaranted Eto Sterlized, Prefilled Heavy Dencity 10000 Glass Syring 2Ml , Viscoelastic Material - Made By Reputed Company Guaranted Eto Sterlized, Prefilled Heavy Dencity 10000 Glass Syring 3Ml , Viscoelastic Material - Made By Reputed Company Guaranted Eto Sterlized, Prefilled Heavy Dencity 10000 Glass Syring 5Ml , Visiter Chair Three Seater Mettalic With Handle (Ss) , Vtm - Hi - Media With 2 Swab : (For Swine Flu) Vtm Standard Kit(3Ml Vial With 2 Regular Swabs) , W/V Available Iodine In A Non-Oxynol With Solubleiodine Suractant Base With Sodium Iodide(Less Than 1% W/V And Surfactant Less Than 5% W/V500 Ml), Consumable , Wall Fan -18 Complete & Instaltion Charge (Standardisi/Iso Reputed Company) , Wall Thermometer , Warm Bag , Warm Sleeping Bag For Neonates , Wash Bottel Plastic 500Ml , Washing Machine Have Appliance 7Kg , Waste Matarial Drum Swing Model 30 Ltr. , Waste Matarial Drum Swing Model 60 Ltr. , Water Bath Rectangular Thermostatic (Double Walled)- Spec.In Is A Double Bath With Inner Chamber Made Of Stainless Steel And Outer Wall Made Of M.S Duly Powder Coated Paint.The Gap Beteween Outer And Inner Wall Is Filled With Special Glass Wool Insulation.The Conecntric Ring Can Be Removed To Accommodate Containers Of Various Sizes. Temperature From Ambient To 100 Digree+1Digree C Is Controlled By Improted Thermostant. 355X405x100mm (12 Holes Of 75Mm Dia) 14 Ltrs., Urnie Analyzer ;-Long Life Light Illminator Measuring System With 4 Wavelenght Improves The Sensitivity Accuracy And Precision Of The Result . Use Can Edit Sample Id/Patient Name . Automatically Detects The Test Strip. Can Be Connected With Exeternal Barcode Reader&Urine Sediment Analyzer. Sutable Strip Uts-8,10,11,&11 Ma , Water Cooler 150X150ltr Isi Market , Water Cooler 20X40 Ltr Isi Market , Water Cooler 40X80 Ltr Isi Marked , Water Cooler 60X120ltr Isi Marked , Water Cooler With Dispenser (20 Litre) Isi Mark , Wbc Dialuation Fluid(Mfg- Precious Life Care Pvt Ltd)(500 Ml Bottle),Consumable , Wbc Diluting Fluid 500Ml , Wbc Pipet , Weghing Machine , Weighing Machine (1Gm To100gm) , Weighing Machine Pediatrics , Weight3.00Kg , Wheel Chair With Hand, Foot And Neck Rest Ss, , Whitacre - Pencil Point Spinal Needle 25 G With Introducer , White Petrollium Jelly 1Kg , White Petrollium Jelly 20 Kg , Widal 4X5 Ml [987811] , Widal Slide Test(4X5m1 With Control),Consumab , Widdal 2X2 Tube Test Kit For Typhoid , Widdle Reapid Test Cardsingle Test , Widdle Reapid Test Card Antigen Pack Of 50Ml , Wiper Medium Size , Wiper Standard Size , Wooden Stick/Broom Stick (8Inches) , X-Rayfilm (Dihl),Consumable 8 Inchx 10 Inch , X-Ray Cassets With Screen Size 10X12 , X-Ray Cassets With Screen Size 12X15 , X-Ray Cassets With Screen Size 8X10 , X-Ray Cassets(6.5X8.5),Consumable , X-Ray Cassets(8X10),Consumable , X-Ray Chest Stand , X-Ray Developer Powder (13.5 Liter),Consumable , X-Ray Film 10 X 12 50 Sheets/Pack , X-Ray Film 10X12(50 Sheet/Pack),Consumable , X-Ray Film 12 X 12 50 Sheets/Pack , X-Ray Film 12 X 15 50 Sheets/Pack , X-Ray Film 12X15(50 Sheet/Pack),Consumable , X-Ray Film 14 X 14 50 Sheets/Pack , X-Ray Film 14 X 17 50 Sheets/Pack , X-Ray Film 6.5 X 8.5 50 Sheets/Pack , X-Ray Film 8 X 10 50 Sheets/Pack , X-Ray Film 8X10(50 Sheet/Pack),Consumable , X-Ray Film Digital 11X14 , X-Ray Film Digital 14X17 , X-Ray Film Digital 8X10 , X-Ray Film Fixer(Powder To Make 13.5 Liters-Pkt),Consumable , X-Ray Film Fixer(Powder To Make 9 Liters-Pkt),Consumable , X-Ray Film-Polyster Based Imaging Film 35.6Cmx43.2Cm (14X17)(Size-50 Sheet In One Packet),Consumable , X-Ray Fixer 13.5 Lit , X-Ray Fixer 22.5 Lit , X-Ray Flimpack Of 1X50 Size 10 Inchx 12 Inch(Dihl),Consumable , X-Ray Flimpack Of 1X50 Size 14 Inchx 17 Inch(Dihl),Consumable , X-Ray Grid 12X15 , X-Ray Grid 8X10 , X-Ray Half File Glomer 6X15 , X-Ray Half File Glomer 6X17 , X-Ray Hanger Size 10X12 , X-Ray Hanger Size 12X15 , X-Ray Hanger Size 6.5X8.5 , X-Ray Hanger Size 8X10 , X-Ray Hangers(10X12),Consumable , X-Ray Hangers(12X15),Consumable , X-Ray Hangers(6.5X8.5),Consumable , X-Ray Hangers(8X10),Consumable , X-Ray Lead Number (A To Z & 0 To 9) , X-Ray Led Aprin Standard Size , X-Ray Led Gloves , X-Ray Steel Ka Tank 13.5 Lit. , X-Ray Steel Ka Tank 19 Lit. , X-Ray Table For Patient Examine , X-Ray View Box Double , X-Ray View Box Single , X-Ray View Box With Auto Sensor (Four Film) , X-Ray View Box With Auto Sensor (One Film) , X-Ray Film-Polyster Based Imaging Film 30.5Cmx30.5Cm (12X12)(Size-50 Sheet In One Packet),Consumable , X-Ray Film-Polyster Based Imaging Film 35.6Cmx35.6Cm (14X14)(Size-50 Sheet In One Packet),Consumable , 2Tu Ppd Vial 5Ml , Xylene (Sulphur Free)(1 X 2.5 Lit),Consumable , Zipper Ploy Bag 4X4 , Zipper Ploy Bag 4X6 , Zipper Ploy Bag 9X6 , Zipper Poly Bag (Size 5”X3”) , Zipper Poly Bag (Size 6”X5”) , Zipper Polybag 10X8’’ , Zipper Polybag 8’X6’ , Poly Bag Black 16X18’’ , Air Conditioner Window 1.5 Ton 3 Star , Air Conditioner Window 2 Ton 3 Star , Air Conditioner 1 Ton Split 3 Star , Air Conditioner 1.5 Ton Split 3 Star , Air Conditioner 2 Ton Split 3 Star , Stabilizer For Ac , Office Almirah , Laser Printer , Laser Printer All In One , Inkjet Printer , Desktop I3 Windows 11 , Desktop I5 Windows 11 , Public Place Seater Bench Ss Without Backrest , Ultrasound Unit (1 Mhz) For Physiotherapy , Foot Drop Splint , Cock Up Splint , Finger Splint , Tens Machine , Display Board With Glass , Laptop I5 Window 11 , Shoulder Wheel , Finger Exerciser Web , Shoulder Pully T-Type , Spiro Meter With Disposal Mouth Piece , Lower And Upper Extremity Static Cycle , Iron Rack , Industrial Rack , Exicutive Revolving Chair , Zip Lock Polythene Pp Pouche 12 To 19 Inch , Zip Lock Polythene Pp Pouche 6 To 9 Inch , Straight Plastic Brush , Centrifuge Tube 50Ml , Card Bord Box Small , Laminar Air Flow , Filter Paper , Biohazard Polythene Bag , Three Seater Chair , Cupboard (Closed Rack) , Water Cooler 60Ltr , 8.0 Silk Suture , Dispovan Syringes 10Ml , Dispovan Syringes 05 Ml , Blood Transfusion Set , Iol Non Foldable Lenses , Black Gogles , Micropore Paper Tape 4 Inch , Micropore Paper Tape 1 Inch , Cotton Bundles , Sterile Pad , K Wires 1 1.5, 2, 2.5 Mm , Hand Drill , Hydrolic Ot Table , English Plier , Bone Holding Forcep For Radius Ulna Bone , Bone Holding Forcep For Humerus Bone , Bone Holding Forcep For Femur Bone , Tbw Ss Wires No. 18, 20,22 No. , Patella Holding Forcep Large , Patella Holding Forcep Small , Plate Holding Forcep Small , Plate Holding Forcep Medium , Plate Holding Forcep Large , K-Wire Cutter Medium , K-Wire Bender Steel , T Handle & Ss Chuck Small , T Handle & Ss Chuck Large , Wire Passser Small , Retractor Right Angle Medium , Retractor Right Angle Small , Retractor Right Angle Large , Bone Spikes Small , Bone Spikes Medium , Hohmann Retractor , Bone Cutter Small , Lenz Bone Holding Forcep , Towel Clips Small , Towel Clips Medium , Steel Drill Bits 2.7Mm 3.2Mm 3.5 Mm Steel , Screw Driver For 3.5 Mm Screws , Canullated Drill Bit For4mm Screws , Canullated Tap For4mm Screws , Steel Hammer Heavy , Bone Punch , Currete Straight , Currete Curved , Osteotome Small , Osteome Medium , Osteotome Large , Bone Gauze Small , Bone Gauze Medium , Bone Gauze Large , Electric Drill Set Man Man , Canulated Reamers For Femur , Hooks For K Nail Retractor , Reamers For Radius Ulna Nailing , Extractor For Radius Ulna Nailing , Drill Sleev For 2.7 & 3.2 Mm Drill Bits , Hoilow Mill , Zigli Saw , Eletric Torniquet , Pneumatic Tourniquet , Radient Warmer , Ambu Bag Pediatric , Suction Machine Foot Oprated , Suction Machine Electric , Thermameter , Hub Cutter , Oxygen Tube , Oxygen Hood , Oxygen Mask , Stethpscope , Laringoscope , Laringoscope Blade 0 No , Laringoscope Blade 1 No , Tourch , Infentometer , Measuring Tape , Diamond Marker , Tissue Roll , Marker Pen Red Black , Auramine -O , Hydrochloride Acid , Broom Stick , Zipper Polythene , Measuring Cylinder 1000Ml , Measuring Cylinder 500Ml , Methnol , Apron Coton , Bio Hazard Lables , Amber Coloured Bottle 250Ml , Brown Tape , Slide Box For 100 Slide , Beaker 500Ml , Glass Ware For Stain Preparation Meassuring Cylinder-Graduated 100Ml , Glass Ware Round Flate Bottom Flask-1 Lit , Stainless Steel Scissors , Water Bath Digital , Hand Wash 1000Ml , Laminar Air Flow , Towel , Rack Steel , Lens Paper , Ppd Vial 2 Tu , Ppd Vial 5 Tu , Distilled Water , Spirit Lamp Steel , Phenyl 40% , Tri Sodium Citrate , Di Sodium Hydrogen Phosphate , Potassium Di Hydrogen Phosphate , N-Acetyl L-Cystein , Glass Slide , Cryo- Vial Sterilr With Cap 1.5Ml , Tips 200 ?L Sterile With Box , Tips 1000?L Sterile With Box , Tips 1250?L Sterile With Box Long 1Ml , Bags For Waste Bin Black 30L , Bags For Waste Bin Red 30L , Bags For Waste Bin Blue 30L , Disposable Laboratory Coat Large White Colour , Disposable Laboratory Coat Medium White Colour , Disposable Laboratory Coat Large Blue Colour , Disposable Laboratory Coat Medium Blue Colour , Storage Box With Lid For 0.2 Ml Pcr Tube , Steel Rack For 50 Ml Conical Tube , Plastic Rack For 50 Ml Conical Tube 24 Position , Sodium Hypochloride , Pasteur Pipette Individually Packed Sterile 3Ml , 50 Ml Pptubes For Centrifuge , Pcr Tube 0.2 Ml , Falcon Tube Stand , Refrigrator 322 Liter , Ups Double Battery , Ceiling Fen , Delivery Table , Labour Table Mettres , Almirah , R O Machine , Auto Clave Drum Large , Auto Clave Drum Medium , Auto Clave Drum Small , Kidney Tray , Dental Chair , Uv Chamber , Ultrasonic Scale , Compressor For Dental Chair , Glass Bed Sterilize , Aerotor , Xtracton Forcip Set , Elevator Set , Diagnostic Instrument Set For Dental , Glass Slab , Restrotiv Instrument Set , Enoo Motor , Rbg Size 2 Digital Infra Oral Xray Sensor With Desktop , Aerotor Burs , Artery Forcip , Episiopomy Ceizer , Bowl , Thumb Forcip , Delivery Tray , Office Table , Plane Seizer , Stich Cutter , Needle Holder , Spung Holder , Chittle Forcip , Cord Cutting Seizer , Tooth Forcip , Non Tooth Forcip , Knife Holder , Bp Insturment Digital , Cidex Tray , Mezenba Seizer , Ot Fogging Machine , Weight Machine Adult , Office Chair , Nebulizer , Foot Step , Plastic Chair , Invertor With Battery , Rivolving Chair , Patient Stool , Drug Cart , Stadiometer , Examination Table , Fetal Dopler , Thermometer , Flying Catcher , Autoscope , Bio Waste Bucket , Digital Wall Clock , Equipment Tray , Fire Extinguisher , Three Buckt Trolly , Crash Card Trolly , Delivery Set , Epigiotomy Set , Mtp Medicine Set , Multipera Monitor 5 Pera , Ot Table , Ot Table Hydrolic , Ot Light Celing , Spot Light , Hb Meter , Exhaust Fen , Suction Machine Electric , Finger Print Scaner Machine , Plastic Tub , R O Machine 60 Liter , R O Machine 80Liter , Kmc Chair , Electric Water Geyser 10 Ltr.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
Madhya Pradesh View Result →
24.
Civil Aviation #10292373 Price Bid
Tender For Up gradation Of Low Side Hvac System At Amritsar Airport.; 1 Supply, Installation, Testing and commissioning of factory built floor mounted chilled water double skin type horizontal air handling unit (for chilled water centralised AC plant) made of 25 mm thick panels consisting of pre plasctized G.I. casing of thickness 0.8 mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators, cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.5 mm) cooling coil of following row deep, filter section with 50 mm thick metal viscous/ washable synthetic type air prefilters, belt drive package with TEFC drive motor of efficiency class IE 3 suitable for 415 ± 10 % volts, 50 Hz , 3 Phase AC supply suitably designed for variable frequency drive applications, drain connections, stainless steel (18 G) drain pan with PUF insulation, 150 mm dia. dial type pressure guages (2 nos.) and industrial type thermometers (2 nos.) at the inlet and outlet of coil, auto purge valve wherever required, necessary vibration isolation arrangement etc. complete as per specifications and of following capacities. 2 40900 CFM (8 Row deep) 3 39300 CFM (8 Row deep) 4 30950 CFM (8 Row deep) 5 29623 CFM (8 Row deep) 6 35000 CFM (6 Row deep) 7 31700 CFM (6 Row deep) 8 31500 CFM (6 Row deep) 9 30700 CFM (6 Row deep) 10 23700 CFM (6 Row deep) 11 18500 CFM (6 Row deep) 12 12000 CFM (6 Row deep) 13 5000 CFM (6 Row deep) 14 Supply, Installation, Testing and commissioning of factory built floor mounted chilled water double skin type Vertical type air handling unit (for chilled water centralized AC plant) made of 43± 2 mm thick panels consisting of Pre-coated G.I. Sheet casing of thickness 0.6 mm outside layer and 0.6 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection molding machine with 40±2 kg /M³ of density , complete with blower section with blower suitable for static pressure as required, cooling coil section with aluminum finned copper tubes (tube thickness not less than 0.41 mm) cooling coil of following row deep, filter section with 50 mm thick metal viscous/ washable synthetic type Pre filters having efficiency 90% down to 10 micron, belt drive package with TEFC drive motor of efficiency class IE 3 suitable for 415 ± 10 % volts, 50 Hz , 3 Phase AC supply suitably designed for variable frequency drive applications, drain connections, stainless steel (18 G) drain pan with PUF insulation, vibration isolation arrangement etc. complete as per specifications and of following capacities.AHU Coil shall be AHRI Certified. Bidder has to submit the AHRI certificate along with technical data sheet approval. AHU Motor & blower shall be compatible to operate with VFD.Outlet velocity of air should not be more than 9.26 m/s.The Face velocity ofcoils should not be more than 500 . AHU should have protection like LimitSwitch, Door Lamp, Inspection Glass etc. 15 10000 CFM (6 Row deep) Vertical 16 Supply, installation, balancing and commissioning of fabricated at site/factory GSS sheet metal rectangular/roundducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 17 Thickness 0.63 mm sheet 18 Thickness 0.80 mm sheet 19 Thickness 1.00 mm sheet 20 Thickness 1.25 mm sheet 21 Supply, fixing, testing and commissioning of following insulated valves as per specification 22 Butterfly valve (Manual) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilledwater/hot eater circulation as specified. 23 32 mm dia. 24 65 mm dia. 25 80 mm dia. 26 100 mm dia. 27 Balancing valve with built in measuring facility with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. 28 32 mm dia. 29 65 mm dia. 30 80 mm dia. 31 100 mm dia. 32 3 way motorized valve, CI body, brass seating, S.S 304 spindle, spring loaded packing with teflon rings and rubber seal, PN-16 rating and flange end connection max temperature 90°C with 24V AC/DC linear motion electric actuator, IP-64 rated. 33 32 mm dia. 34 65 mm dia. 35 80 mm dia. 36 100 mm dia. 37 Y - Strainer of ductile CI Body flanged ends with stainless steel strainer for chilled/ hot water circulation including insulation as specified. 38 32 mm dia. 39 65 mm dia. 40 80 mm dia. 41 100 mm dia. 42 Supplying, fixing, testing and commissioning of fire dampers in supply air duct / main branch and return air path as and where required of required sizes i/c control wiring. The damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as requried and as per specifications. 43 Fire damper 44 Actuator 45 Supply & Fixing of new waterproof/fire retardant canvass connection for new AHUs complete with GI frame and hardware. 46 SITC of 15mm Automatic Air purge valve. 47 SITC of 15mm Ball Valve. 48 SITC of Dial type pressure gauge along with the syphon tube and ball cock. 49 SITC of mercury-in glass thermometer. 50 Supply and Installation testing of Digital thermostat for AHUs Temperature control. 51 Supply, laying , connecting , fixingand testing of Chilled water MS ERW class C pipe complete with all fitting duly insulated as mentioned their in for closed cell elastomeric insulation 30 to 40 kg /cum density& 26 G Aluminum cladding laidunderground/flooretccompleteallasspecifiedanddirectedforthe following pipes : - 52 150 mm -32 mm thick insulation 53 125 mm -32 mm thick insulation 54 100 mm -25 mm thick insulation 55 80 mm -25 mm thick insulation 56 65 mm -25 mm thick insulation 57 32 mm-25 mm thick insulation 58 Supply,layingandfixingofdrainpipeofGITubingMediumgradewithall fittingsforcableprotectionlaidintrenchesorfixedtowall/laidinflooring, complete all as specified and directed. 59 25 mm 60 32 mm 61 Supply & Fixing of closedcellelastomericnitrilerubberhavingthermalconductivitynot exceeding0.037W/mKatmeantemperatureof20°CasperEN12667, moisturediffusionresistancefactoror‘µ’valueofminimum7,000forbase insulation material without the foil as per EN 12086, fire performance such that it passes Class O as per BS476 Part 7 for surface spread of flame , density without the foil between 40 to 55 kg/cum. The insulation material shall be dust & fibre free. The Aluminum foil shall be 60 microns thick and its weight shall be 193 gsm as per EN ISO 2286-2, tensile strength 90 N / 15 mm as per EN ISO 527-3withelongation>10%asperENISO527-3,completeforfollowing thickness of insulation all as specified and directed. 62 19 mm thick thermal insulation 63 Supply,Installation, TestingandCommissioning ofAcousticlininginside ducts/plenum using open cell nitrile rubber foam having micro-ban anti- microbial/ anti fungal product protection and of 160-180 kg / m³ density as per ASTM D3575, class 1 rating As per BS476,PART-7, cut to required sizes and tobestucktotheinsideofductsurfaceswithadhesiveasapprovedbythe manufacturer. (Rubber based solvent). as per specifications 64 10mm thick sound board 65 Supply,installation,testingandcommissioningofGIvolumecontrolduct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. 66 SITC of Aluminum Construction Supply air grill with aluminum VCD 67 SITC of Aluminum Construction Return air grill without VCD 68 Supplying,fixingtestingcommissioningofAluminumSupplyairdiffusersof powder coated with aluminum volume control dampers with anti smudge ring & removable core. 69 Supplying,fixingtestingcommissioningofAluminum Returnairdiffusersof powdercoatedwithoutvolumecontroldamperswithantismudgering& removable core. 70 Supplying,installation,testingandcommissioningof 300 mmdiaJetdiffuser with volume control dampers for supply air as per specifications,complete all as specified and directed. 71 Supplying, fixing, testing and commissioning of powder coated extruded aluminumsection freshairgrillinweathermakerroomwithvolumecontrol dampers complete as required as per site condition. 72 Supply, fabrication, installation and testing of flexible connection constructed of fire resistant double resin sleeve as per approved shop drawings and specifications, complete all as specified and directed. 73 SITC of Aluminum Construction damper for existing grill 74 SITCofAirbalancingof AHUforproperAirflowthroughNADCAcertified Agency VendorhastosubmittheReport&NADCAcertificateofagency before starting of work. 75 AHU No 1 - 39300 CFM 76 AHU No 2 - 29623 CFM 77 AHU No 3 - 23 700 CFM 78 AHU No 4 & 5 - 30700 CFM 79 AHU No 6 - 31500 CFM 80 AHU No 7 - 40900 CFM 81 AHU No 8 - 30950 CFM 82 AHU No 9 & 10- 35000 CFM 83 AHU No 11 - 18500 CFM 84 AHU No 12 & 13 - 12000 CFM 85 AHU No11 - 31700 CFM 86 AHU No 13 - 5000 CFM 87 Robotic Duct Cleaning :Removing refixing and cleaning of inside surface of supply & return air ducts, grills & diffusers of HVAC system by busing high power vacuum having HEPA filter, air compressor,robotic camera, air hammer, special nozzles,air sweep with all other required accessories and inspection of duct duct before and after cleaningusingcolourvideominimumat4placeineachAHUandmopping withtherecommendedchemicaldisinfectantsuchasKorsole/Microbac forte Sokrena or Equivalent inside the surface if supply air duct.Note:AllthecleaningworkshouldbecarriedoutbyNADCAcertified approvedagencyonly.ContractorhastosubmittheNADCAcertificateof agency before starting ofexecution activity.Mode of Measurement : Mode Of Measurement : Carpet area of Air conditioning space, AHU room and the area where duct is fixed . 88 Supply and laying of 3 c x 1.5 Sqmm PVC insulated flexible control cable . 89 SITC of wall mountable LT panel made of 1.6 mm thick mild steel CRCA steel confirming to IP 43 having suitable size of Al. Bus bars suitable for 3 Phase , 4 wire , 50 Hz AC supply system with following switchgear and accessories –Incomer :(i) 80 A, 415 V, Ics = Icu = 25 kA, 50 Hz FP MCCB with adjustableoverload settings,adjustableshort-circuitsettingsandThermalMagneticbasedtrip. Incomer have one multifunction meter along with Indicating light.Outgoing :(i) AHU starter shallbe design with VFD (matching with AHU motor capacity . Suggested>22kwto<=30KW) ofcapacityasperapprovedTDSofAHU motor with bypass starter arrangement.Thereshould be Auto manual selector switch for VFD & by pass starter along withindicatinglightpushbuttononoff & ManualVFDFrequencycontrol switch/Regulator to control the VFD speed manually.(ii)6AMPDPMCBwithcontactor,toggleswitch,indicatinglightshallbe provided for 3 way valve & Fire Damper Actuator/Humidifier- 3 nos. 90 SITC of wall mountable LT panel made of 1.6 mm thick mild steel CRCA steel confirming to IP 43 having suitable size of Al. Bus bars suitable for 3 Phase , 4 wire , 50 Hz AC supply system with following switchgear and accessories –Incomer :(i) 63 A, 415 V, Ics = Icu = 25 kA, 50 Hz FP MCCB with adjustableoverload settings,adjustableshort-circuitsettingsandThermalMagneticbasedtrip. Incomer have one multifunction meter along with Indicating light.Outgoing :(i) AHU starter shallbe design with VFD ( matching with AHU motor capacity . Suggested>15kwto<=22KW) ofcapacityasperapprovedTDSofAHU motor with bypass starter arrangement.Thereshould be Auto manual selector switch for VFD & by pass starter along withindicatinglightpushbuttononoff & ManualVFDFrequencycontrol switch/Regulator to control the VFD speed manually.(ii)6AMPDPMCBwithcontactor,toggleswitch,indicatinglightshallbe provided for 3 way valve & Fire Damper Actuator/Humidifier- 3 nos. 91 SITC of wall mountable LT panel made of 1.6 mm thick mild steel CRCA steel confirming to IP 43 having suitable size of Al. Bus bars suitable for 3 Phase , 4 wire , 50 Hz AC supply system with following switchgear and accessories –Incomer :(i) 63 A, 415 V, Ics = Icu = 25 kA, 50 Hz FP MCCB with adjustableoverload settings,adjustableshort-circuitsettingsandThermalMagneticbasedtrip. Incomer have one multifunction meter along with Indicating light.Outgoing :(i) AHU starter shallbe design with VFD ( matching with AHU motor capacity . Suggested>7.5kwto<=15KW) ofcapacityasperapprovedTDSofAHU motor with bypass starter arrangement.Thereshould be Auto manual selector switch for VFD & by pass starter along withindicatinglightpushbuttononoff & ManualVFDFrequencycontrol switch/Regulator to control the VFD speed manually.(ii)6AMPDPMCBwithcontactor,toggleswitch,indicatinglightshallbe provided for 3 way valve & Fire Damper Actuator/Humidifier- 3 nos. 92 SITC of wall mountable LT panel made of 1.6 mm thick mild steel CRCA steel confirming to IP 43 having suitable size of Al. Bus bars suitable for 3 Phase , 4 wire , 50 Hz AC supply system with following switchgear and accessories –(i) 32 A, 415 V, Ics = Icu = 16 kA, 50 Hz FP MCCB with adjustableoverload settings,adjustableshort-circuitsettingsandThermalMagneticbasedtrip. Incomer have one multifunction meter along with Indicating light.Outgoing :(i) AHU starter shallbe design with VFD ( matching with AHU motor capacity . Suggested>3.7kwto <=7.5KW) of capacityas perapprovedTDS of AHU motor with bypass starter arrangement.Thereshould be Auto manual selector switch for VFD & by pass starter along withindicatinglightpushbuttononoff & ManualVFDFrequencycontrol switch/Regulator to control the VFD speed manually.(ii)6AMPDPMCBwithcontactor,toggleswitch,indicatinglightshallbe provided for 3 way valve & Fire Damper Actuator/Humidifier- 3 nos. 93 SITC of wall mountable LT panel made of 1.6 mm thick mild steel CRCA steel confirming to IP 43 having suitable size of Al. Bus bars suitable for 3 Phase , 4 wire , 50 Hz AC supply system with following switchgear and accessories –Incomer :(i) 16 A, 415 V, Ics = Icu = 10 kA, 50 Hz FP MCCB with adjustableoverload settings,adjustableshort-circuitsettingsandThermalMagneticbasedtrip. Incomer have one multifunction meter along with Indicating light.Outgoing :(i) AHU starter shallbe design with VFD ( matching with AHU motor capacity . Suggested <=3.7 KW) of capacity as per approved TDS of AHU motor with bypass starter arrangement.Thereshould be Auto manual selector switch for VFD & by pass starter along withindicatinglightpushbuttononoff & ManualVFDFrequencycontrol switch/Regulator to control the VFD speed manually.(ii)6AMPDPMCBwithcontactor,toggleswitch,indicatinglightshallbe provided for 3 way valve & Fire Damper Actuator/Humidifier- 3 nos. 94 Supplying & installing following sizes of perforated Galavanised Iron cable tray with perforation more than 17.5 % in convenient sections, joined with connectors,suspendedfrom ceilingwithGI suspendersincludingGI Bolts& nuts etc. as required 95 300 mm x50mm x 1.6mm 96 100 mmX 50 mm X 1.6 mm 97 SITC of MS iron for support including one coat of red oxide & one coat of black paint . 98 SITC of GI strip of size 25 mm x 3 mm as earth lead fixed to wall on batten or recess or chases or buried in ground or drawn in cable tray for loop earthing etc complete all as specified and directed. 99 Providing and fixing 8 SWG dia G.I. wire on surface or in recess for loop earthing as required. 100 Dismantling of existing AHU of following CFM and shifting the dismantled material to AAI stores as directed by EIC. 101 29000 CFM 102 24500 CFM 103 23000 CFM 104 19167 CFM 105 18500 CFM 106 13530 CFM 107 12000 CFM 108 Supply of following sqmm, 1.1 KV grade, XLPE insulated, PVC sheathed, armoured, aluminum conductor power cable conform to IS 7098 (part -1) with up to date amendments etc complete as required. 109 4 C x 10 sqmm 110 4 C x 6 sqmm 111 3.5 C x 35 sqmm 112 3.5 C x 25 sqmm 113 3 C x 35 sqmm 114 3 C x 25 sqmm 115 3 C x 10 sqmm 116 3 C x 4 sqmm 117 Supply of 4 C x 4 sqmm, 1.1 KV grade, XLPE insulated, PVC sheathed, armoured, copper conductor power cable conform to IS 7098 (part -1) with up to date amendments etc complete as required. 118 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface/existing cable tray as required. - upto 35 Sq. mm. 119 Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE Al. conductor cable of 1.1 kV grade as required. 120 4 C x 10 sqmm (25 mm) 121 4 C x 6 sqmm (25 mm) 122 3.5 C x 35 sqmm (32 mm) 123 3.5 C x 25 sqmm (28 mm) 124 3 C x 35 sqmm (28 mm) 125 3 C x 25 sqmm (25 mm) 126 3 C x 10 sqmm (22 mm) 127 3 C x 4 sqmm (22 mm) 128 Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class ‘O’insulation applied by suitable rubber based adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. 129 Chilled water piping of nominal size - 200mm dia. (32mm thick nitrile rubber) 130 Chilled water piping of nominal size - 150mm dia. (32mm thick nitrile rubber) 131 Chilled water piping of nominal size - 100mm dia. (32mm thick nitrile rubber) 132 Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping in ground (with necessary fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class ‘O’insulation applied by suitable rubber based adhesive complete including exavation & providing cement concrete blocks as supports,etc. as per specifications and as required complete in all respect 133 Chilled water piping of nominal size - 200mm dia. (32mm thick nitrile rubber) 134 Chilled water piping of nominal size - 150mm dia. (32mm thick nitrile rubber) 135 Supplying and fixing aluminium sheet cladding on 200mm dia. (32mm thick nitrile rubber) ofchilled water piping complete as per specifications and as required complete in all respect. 136 Supplying and fixing aluminium sheet cladding on 150mm dia. (32mm thick nitrile rubber) ofchilled water piping complete as per specifications and as required complete in all respect.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 8
25.
Drinking Water Supply and Sanitation #10254164 Price Bid
Providing And Installation Of Electro Mechanical Equipments And Allied Works For Arsenic Removal Plant At Sonada Zone-I Piped Water Supply Scheme Block_ Krishnanagar-I Dist. - Nadia Under Emd, Phe Dte-2 Supply, Delivery And Storage At Site Of Horizontal Split Casing Centrifugal Pumping Machineries With Baseplate, Flexible Coupling, Coupling Guard, Foundation Bolt Etc. Having The Following Specification And As Pernit. : ( Pumps Suitable For Plc Operated Unmaned Operation Facility ) ( For Pumping Water From Cwr To Ohr ) Discharge :- 34 M3 Per Hour Generated Head :- 40 Mwc H-Q-P Curve Of Pumps In Test Bed Has To Be Submitted During The Delivery. 3 Supply, Delivery And Storage At Site Horizontal Foot Mounted Induction Motor Suitable For The Pump Duty Mentioned Above ( Item No- 1 ) With Adequate Margin As Specified In The Nit. Routine Test Certificate Of Induction Motor Has To Be Submitted During Delivery 4 Supply, Delivery And Storage At Site Of Monoblock Vacuum Pumping Machinarywith The Following Specification And As Pernit. : A ) Vacuum : Upto 600 Mm Of Hg B ) Air Flow Rate :1.8 To20.5M3 / Hr 5 Supply, Delivery And Storage At Site Lift Type 80 Mm Foot Valve Combined With Stainer As Per Is : 4038 Pn-0.6 And As Per Detail Given In The Nit . :-N.B. : Test Certificate To Be Produced For Each Valve ( At Suction Side Of Pump ) 6 Supply, Delivery And Storage At Site Of Ci Doble Flanged Single Door Swing Check80 Mm Dia N.R.Vas Per Is : 5312, Part-I, Pn-1.0 And As Per Detail Given In Nit. :-N.B. : Test Certificate To Be Produced For Each Valve. ( At Delivery Side Of Pump ) 7 Supply, Delivery And Storage At Site 80 Mm Diacast Iron Actuator Operated Wafer Type Butterfly Valvegenerally Conforming To Is:13095 And Pn-1.0. And As Per Detail Given In Nit. :-N.B. : Test Certificate To Be Produced For Each Valve ( At Delivery Side Of Pump ) 8 Supply, Delivery And Storage At Site 80 Mm Diadouble Flanged Cast Iron Manually Operated Non-Rising Spindle Sluice Valve Generally Conforming Tois:14846 Pn-1.0.And As Per Detail Given In Nit. :-N.B. : Test Certificate To Be Produced For Each Valve. ( At Common Delivery Header ) 9 Supply, Delivery And Storage At Site 80 Mm Diacast Iron Kinetic Double Orifice Air Released Valve As Per Relevant Is, Pn-1.0.And As Per Detail Given In Nit. :-N.B. : Test Certificate To Be Produced For Each Valve. ( At Common Delivery Header ) 10 Supply, Delivery And Storage At Site Ms Dismantling Joint Dn 80 Mm Pn 1.0 ( For Delivery Side & Common Header Ofpump ) 11 Supply, Delivery And Storage At Site Bourdon Type Pressure & Compound Gauges, 150 Mm Dia Cast Aluminium Dial With , Ss Internal, Dn 15 Gi Impulse Line With Three Way Cock. 12 A ) Pressure Guages ( 0 - 15 Kg / Cm2 ) 13 B ) Compound Guages ( +1 To -1 Kscg ) 14 Supply, Delivery And Storage At Site Of 80 Mm Dia , Thickness 5.4Mm And 80 Mm Dia 5.4 Mm Thick Ms Black Pipe Conforming To Is:3589 Gr.330 ( For Suction, Delivery & Delivery Header ) Along With Necessarybends, Fittings Viz. Flanges, Bolts, Nuts, Gaskets , Concentric Enlarger50 X 80 Mm Etc. As Reqd. To Make The Installation Complete In All Respect Andas Pernit. 15 Supply Delivery And Storage At Site Of Ultrasonic / Radartype Continuous Level Measuring Unit With Provision Of 4 To 20 Ma Analogue Signal, Indicator And Recorder For Continuous Level Monitoring As Well As 5 Nos. Relay Out Put For Sensing High, Low, Low - Low Level In Suction Sump As Per Specification Given In Nit. 16 Supply, Delivery And Storage At Site20 Mm Dia, G.Ipipes ( Medium Duty ) , Water Storage Pvc Tank , Bends, Sockets, Tees, Fittings, And Other Specials, Gaskets , Solenoide Valve , Gate Valve For Auto & Manual Operation Etc. As Reqd. To Make The Piping Arrangement Of Vacuum Pumpcomplete In All Respect As Pernit. ( For Priming Arrangement ) 17 Supply, Delivery And Storage At Site 2 Mm. Thick Crca Sheet Steel Enclosed Cubical Type Indoor Floor Mounted415 Volt Mccpanelhaving Required Feeders With Plc As Per Specification Given In Nit. 18 Supply, Delivery And Storage At Site 2 Mm. Thick Crca Sheet Steel Enclosed Cubical Type Indoor Wall Mounted415 Volt Power Distribution Board Having Required Feedersas Per Specification Given In Nit. 19 Supply, Delivery And Storage At Site 1.1 Kv Grade35 Mm2 3½Core Xlpe Insulated Cupper Armoured Cable As Per Technical Specification Of Nit. ( From Cut Out To Pdb Panel ) ) 20 Supply, Delivery And Storage At Site 1.1 Kv Grade50 Mm2 3½Core Xlpe Insulated Aluminiun Armoured Cable As Per Technical Specification Of Nit. ( For Pdb Panel To Mcc Panel ) 21 Supply, Delivery And Storage At Site 1.1 Kv Grade25 Sq.Mm 3½Core Xlpe Insulated Aluminiun Armoured Cable As Per Technical Specification Of Nit. ( For Voltage Stabilizer To Mcc Panel ) 22 Supply, Delivery And Storage At Site 1.1 Kv Grade 6 Sq. Mm.3Core Xlpe Insulated Aluminiun Armoured Cable As Per Technical Specification Of Nit. ( Formcc Panel To Motor. ) 23 Supply, Delivery And Storage At Site1.1 Kv Grade 2.5 Sq. Mm.12Core Pvc Insulated Armoured Copper Controlcable As Per Technical Specification Of Nit. ( Formcc Panel To Actuator. ) 24 Supply, Delivery And Storage At Site1.1 Kv Grade 2.5 Sq. Mm.2Core Pvc Insulated Armoured Copper Controlcable As Per Technical Specification Of Nit. ( For Solenoid Valve Connection ) 25 Supply, Delivery And Storage At Site1.1 Kv Grade 4Sq. Mm.2Core Pvc Insulated Armoured Coppercable As Per Technical Specification Of Nit. ( For Vaccume Pump Connection ) 26 Earthing & Lightning Protection For Pump House And Electrical Installation As Per Iss And Ie Rules And As Per Technical Specification Of Nit. ( Earth Pit 2 Nos+ 2 L / A ) 27 Supply, Delivery At Site And Storeage Of Gi Perforated Cable Tray At Pump House For Laying Of Incoming & Outgoing Power And Control Cables To And From Mcc Panelhaving Proper M.S. Structural Support As Per Nit Specification And Direction Of Eic. 28 Supply Delivery At Site And Storage Of Illumination Arrangement Like Suitable Size Wire, Switch , Switch Board , Tube Light Fitting , Exhaust Fan , Ceilling Fan , Led Outdoor Fixturecomplete As Per Specification Of Nit. 29 Supply Delivery At Site And Storage Of Safety Equipment Like Suitable Capacity Fire Extinguisher , Sand Bucket , Fire Bracket, Rubber Mats, Shock Treatment Chart And First Aid Box, Chair , Table, 415 Volt Danger Board Complete As Per Specification Of Nit. 30 Supply Delivery At Site And Storage Of Suitable Capacity Power Correction Arrangement As Per Specification Of Nit. 31 Supply Delivery At Site And Storage Of Disinfection Arrangement With Flow Rate 100 Lph As Per Specification Of Nit. 32 Part-B 33 Installation Of All Items As Mentioned In Sl.No.1 To 15 & 23 To 28 ( Part-A ) Including Construction Of Pump Foundations, Pipe Supports, Valve Supports, Laying Of Cables With Necessary Jointing Materials, Earthing Arrangement Of Motors, Starters, Including Supply Of All Erection Items Viz. Rubber Gaskets, Nuts & Bolts Etc., Including Cost Ofwelding Etc. As Required For Complete Installation Including Making Slope Of Floor And Arrangement Of Removing Gland Leckage Wateras Per Hydraulic Standard & Ie Rules In Compliance With Specification Of Nitand Upto Entire Satisfaction Of Eic. 34 Painting Of The Installation ( Viz.Pumps, Valves, Pipe Lines Etc.By Two Coats Of Epoxy Paint ( Colour To Be Decided By Eic ) Over A Coat Of Primer As Per Nit Specifiaction & Direction Of Eic. 35 Testing & Commissioning Of The Entire Installation I.E.Pumps, Motors, Valves Etc. As In Part A ( Sl No. 1To 28 ) As Per Direction And To The Entire Satisfaction Of E.I.C. 36 Operation And Maintenance Of The Entire Installation In High Lift Pumping Stations On 24 Hrs. Basis Including Guarding For A Period Of 90 Days Are To Be Provided With Supply Of Skilled, Semi-Skilled And Un-Skilled Personnel Including Watch And Ward Personnel From The Date Of Commissioning. During Maintenance Period Supply Of All Consumable Materials Sundrys And Lubricants Are To Be Supplied. Charges Of Electrical Energy During Maintenance Period Will Be Born By The Department. 37 Supervision Charges For Electrical Installation By Licensed Electrician As Per Ie Rules, 1956 Read With Latest Amendments With Overhead Expenditures.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
West Bengal View Result →
26.
Drinking Water Supply and Sanitation #10254160 Price Bid
Providing Electro-Mechanical Equipments And Allied Works For Arsenic Removal Plant At Uttar Tajpur Phase-Ii Piped Water Supply Scheme, Block Karimpur-Ii, Dist. Nadia Under Emd, Phe Dte.-2 Supply, Delivery And Storage At Site Of Horizontal Split Casing Centrifugal Pumping Machineries With Baseplate, Flexible Coupling, Coupling Guard, Foundation Bolt Etc. Having The Following Specification And As Pernit. : ( Pumps Suitable For Plc Operated Unmaned Operation Facility ) ( For Pumping Water From Cwr To Ohr ) Discharge :- 45 M3 Per Hour Generated Head :- 40 Mwc H-Q-P Curve Of Pumps In Test Bed Has To Be Submitted During The Delivery. 3 Supply, Delivery And Storage At Site Horizontal Foot Mounted Induction Motor Suitable For The Pump Duty Mentioned Above ( Item No- 1 ) With Adequate Margin As Specified In The Nit. Routine Test Certificate Of Induction Motor Has To Be Submitted During Delivery 4 Supply, Delivery And Storage At Site Of Monoblockvvacuum Pumping Machinarywith The Following Specification And As Pernit. : A ) Vacuum : Upto 600 Mm Of Hg B ) Air Flow Rate : 1.8 To 20.5 M3 / Hr 5 Supply, Delivery And Storage At Site Lift Type 100 Mm Foot Valve Combined With Stainer As Per Is : 4038 Pn-0.6 And As Per Detail Given In The Nit . :-N.B. : Test Certificate To Be Produced For Each Valve ( At Suction Side Of Pump ) 6 Supply, Delivery And Storage At Site Of Ci Doble Flanged Single Door Swing Check80 Mm Dia N.R.Vas Per Is : 5312, Part-I, Pn-1.0 And As Per Detail Given In Nit. :-N.B. : Test Certificate To Be Produced For Each Valve. ( At Delivery Side Of Pump ) 7 Supply, Delivery And Storage At Site 80 Mm Diacast Iron Actuator Operated Wafer Type Butterfly Valvegenerally Conforming To Is:13095 And Pn-1.0. And As Per Detail Given In Nit. :-N.B. : Test Certificate To Be Produced For Each Valve ( At Delivery Side Of Pump ) 8 Supply, Delivery And Storage At Site 80 Mm Diadouble Flanged Cast Iron Manually Operated Non-Rising Spindle Sluice Valve Generally Conforming Tois:14846 Pn-1.0.And As Per Detail Given In Nit. :-N.B. : Test Certificate To Be Produced For Each Valve. ( At Common Delivery Header ) 9 Supply, Delivery And Storage At Site 80 Mm Diacast Iron Kinetic Double Orifice Air Released Valve As Per Relevant Is, Pn-1.0.And As Per Detail Given In Nit. :-N.B. : Test Certificate To Be Produced For Each Valve. ( At Common Delivery Header ) 10 Supply, Delivery And Storage At Site Ms Dismantling Joint Dn 80Mm Pn 1.0 ( For Delivery Side & Common Header Ofpump ) 11 Supply, Delivery And Storage At Site Bourdon Type Pressure & Compound Gauges, 150 Mm Dia Cast Aluminium Dial With , Ss Internal, Dn 15 Gi Impulse Line With Three Way Cock. 12 A ) Pressure Guages ( 0 - 15 Kg / Cm2 ) 13 B ) Compound Guages ( +1 To -1 Kscg ) 14 Supply, Delivery And Storage At Site Of 100 Mm Dia , Thickness 5.4Mm And 80 Mm Dia 5.4 Mm Thick Ms Black Pipe Conforming To Is:3589 Gr.330 ( For Suction, Delivery & Delivery Header ) Along With Necessarybends, Fittings Viz. Flanges, Bolts, Nuts, Gaskets , Eccentric Reducers , Concentric Enlarger Etc. As Reqd. To Make The Installation Complete In All Respect Andas Pernit. 15 Supply Delivery And Storage At Site Of Ultrasonic / Radartype Continuous Level Measuring Unit With Provision Of 4 To 20 Ma Analogue Signal, Indicator And Recorder For Continuous Level Monitoring As Well As 5 Nos. Relay Out Put For Sensing High, Low, Low - Low Level In Suction Sump As Per Specification Given In Nit. 16 Supply, Delivery And Storage At Site20 Mm Dia, G.Ipipes ( Medium Duty ) , Water Storage Pvc Tank , Bends, Sockets, Tees, Fittings, And Other Specials, Gaskets , Solenoide Valve , Gate Valve For Auto & Manual Operation Etc. As Reqd. To Make The Piping Arrangement Of Vacuum Pumpcomplete In All Respect As Pernit. ( For Priming Arrangement ) 17 Supply, Delivery And Storage At Site 2 Mm. Thick Crca Sheet Steel Enclosed Cubical Type Indoor Floor Mounted415 Volt Mccpanelhaving Required Feeders With Plc As Per Specification Given In Nit. 18 Supply, Delivery And Storage At Site 2 Mm. Thick Crca Sheet Steel Enclosed Cubical Type Indoor Wall Mounted415 Volt Power Distribution Board ( Pdb ) Having Required Feedersas Per Specification Given In Nit. 19 Supply, Delivery And Storage At Site 1.1 Kv Grade35 Mm2 3½Core Xlpe Insulated Cupper Armoured Cable As Per Technical Specification Of Nit. ( From Wbsedcl End Cut Out To Pdb Panel ) ) 20 Supply, Delivery And Storage At Site 1.1 Kv Grade50 Mm2 3½Core Xlpe Insulated Aluminiun Armoured Cable As Per Technical Specification Of Nit. ( For Pdb Panel To Airp Mcc Panel ) 21 Supply, Delivery And Storage At Site 1.1 Kv Grade 25 Sq. Mm. Xlpe Insulated Aluminiun Armoured Cable As Per Technical Specification Of Nit. ( For Pdb To Low Lift Mcc Panel . ) 22 Supply, Delivery And Storage At Site 1.1 Kv Grade 6 Sq. Mm.3Core Xlpe Insulated Aluminiun Armoured Cable As Per Technical Specification Of Nit. ( For Mcc Panel To Motor ) 23 Supply, Delivery And Storage At Site1.1 Kv Grade 2.5 Sq. Mm.12Core Pvc Insulated Armoured Copper Controlcable As Per Technical Specification Of Nit. ( Formcc Panel To Actuator. ) 24 Supply, Delivery And Storage At Site1.1 Kv Grade 2.5 Sq. Mm.2Core Pvc Insulated Armoured Copper Controlcable As Per Technical Specification Of Nit. ( For Solenoid Valve Connection ) 25 Supply, Delivery And Storage At Site1.1 Kv Grade 4 Sq. Mm.2Core Pvc Insulated Armoured Coppercable As Per Technical Specification Of Nit. ( For Vacuum Pump Connection ) 26 Earthing & Lightning Protection For Pump House And Electrical Installation As Per Iss And Ie Rules And As Per Technical Specification Of Nit. ( Earth Pit 2 Nos+ 2 L / A ) 27 Supply, Delivery At Site And Storeage Of Gi Perforated Cable Tray At Pump House For Laying Of Incoming & Outgoing Power And Control Cables To And From Mcc Panelhaving Proper M.S. Structural Support As Per Nit Specification And Direction Of Eic. 28 Supply Delivery At Site And Storage Of Illumination Arrangement Like Suitable Size Wire, Switch , Switch Board , Tube Light Fitting , Exhaust Fan , Ceilling Fan , Led Outdoor Fixturecomplete As Per Specification Of Nit. 29 Supply Delivery At Site And Storage Of Safety Equipment Like Suitable Capacity Fire Extinguisher , Sand Bucket , Fire Bracket, Rubber Mats, Shock Treatment Chart And First Aid Box, Chair , Table, 415 Volt Danger Board Complete As Per Specification Of Nit. 30 Supply And Delivery At Site And Storage Of Suitable Capacity Power Corection Arrangement As Per Specification Of Niet 31 Supply And Delivery At Site And Storage Of Suitable Capacity Disinfection Arrangement With Flow Rate 100 Lph As Per Specification Of Niet 32 Part-B 33 Installation Of All Items As Mentioned In Sl.No.1 To 28 ( Part-A ) Including Construction Of Pump Foundations, Pipe Supports, Valve Supports, Laying Of Cables With Necessary Jointing Materials, Earthing Arrangement Of Motors, Starters, Including Supply Of All Erection Items Viz. Rubber Gaskets, Nuts & Bolts Etc., Including Cost Ofwelding Etc. As Required For Complete Installation Including Making Slope Of Floor And Arrangement Of Removing Gland Leckage Wateras Per Hydraulic Standard & Ie Rules In Compliance With Specification Of Nitand Upto Entire Satisfaction Of Eic. 34 Painting Of The Installation ( Viz.Pumps, Valves, Pipe Lines Etc.By Two Coats Of Epoxy Paint ( Colour To Be Decided By Eic ) Over A Coat Of Primer As Per Nit Specifiaction & Direction Of Eic. 35 Testing & Commissioning Of The Entire Installation I.E.Pumps, Motors, Valves Etc. As In Part A ( Sl No. 1To 28 ) As Per Direction And To The Entire Satisfaction Of E.I.C. 36 Operation And Maintenance Of The Entire Installation In High Lift Pumping Stations On 24 Hrs. Basis Including Guarding For A Period Of 90 Days Are To Be Provided With Supply Of Skilled, Semi-Skilled And Un-Skilled Personnel Including Watch And Ward Personnel From The Date Of Commissioning. During Maintenance Period Supply Of All Consumable Materials Sundrys And Lubricants Are To Be Supplied. Charges Of Electrical Energy During Maintenance Period Will Be Borne By The Department. 37 Supervision Charges For Electrical Installation By Licensed Electrician As Per Ie Rules, 1956 Read With Latest Amendments With Overhead Expenditures.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
West Bengal View Result →
27.
Drinking Water Supply and Sanitation #10254155 Price Bid
Providing Electro-Mechanical Equipments And Allied Works For Arsenic Removal Plant At Ghoralia Zone-Ii Phase-Ii Piped Water Supply Scheme, Block Santipur, Dist. Nadia Under Emd, Phe Dte-2 Supply, Delivery And Storage At Site Of Horizontal Split Casing Centrifugal Pumping Machineries With Baseplate, Flexible Coupling, Coupling Guard, Foundation Bolt Etc. Having The Following Specification And As Pernit. : ( Pumps Suitable For Plc Operated Unmaned Operation Facility ) ( For Pumping Water From Cwr To Ohr ) Discharge :- 28 M3 Per Hour Generated Head :- 40 Mwc H-Q-P Curve Of Pumps In Test Bed Has To Be Submitted During The Delivery. 3 Supply, Delivery And Storage At Site Horizontal Foot Mounted Induction Motor Suitable For The Pump Duty Mentioned Above ( Item No- 1 ) With Adequate Margin As Specified In The Nit. Routine Test Certificate Of Induction Motor Has To Be Submitted During Delivery 4 Supply, Delivery And Storage At Site Of Monoblock Vacuum Pumping Machinarywith The Following Specification And As Pernit. : A ) Vacuum : Upto 600 Mm Of Hg B ) Air Flow Rate :1.8 To20.5M3 / Hr 5 Supply, Delivery And Storage At Site Lift Type 80 Mm Foot Valve Combined With Stainer As Per Is : 4038 Pn-0.6 And As Per Detail Given In The Nit . :-N.B. : Test Certificate To Be Produced For Each Valve ( At Suction Side Of Pump ) 6 Supply, Delivery And Storage At Site Of Ci Doble Flanged Single Door Swing Check80 Mm Dia N.R.Vas Per Is : 5312, Part-I, Pn-1.0 And As Per Detail Given In Nit. :-N.B. : Test Certificate To Be Produced For Each Valve. ( At Delivery Side Of Pump ) 7 Supply, Delivery And Storage At Site 80 Mm Diacast Iron Actuator Operated Wafer Type Butterfly Valvegenerally Conforming To Is:13095 And Pn-1.0. And As Per Detail Given In Nit. :-N.B. : Test Certificate To Be Produced For Each Valve ( At Delivery Side Of Pump ) 8 Supply, Delivery And Storage At Site 80 Mm Diadouble Flanged Cast Iron Manually Operated Non-Rising Spindle Sluice Valve Generally Conforming Tois:14846 Pn-1.0.And As Per Detail Given In Nit. :-N.B. : Test Certificate To Be Produced For Each Valve. ( At Common Delivery Header ) 9 Supply, Delivery And Storage At Site 80 Mm Diacast Iron Kinetic Double Orifice Air Released Valve As Per Relevant Is, Pn-1.0.And As Per Detail Given In Nit. :-N.B. : Test Certificate To Be Produced For Each Valve. ( At Common Delivery Header ) 10 Supply, Delivery And Storage At Site Ms Dismantling Joint Dn 80 Mm Pn 1.0 ( For Delivery Side & Common Header Ofpump ) 11 Supply, Delivery And Storage At Site Bourdon Type Pressure & Compound Gauges, 150 Mm Dia Cast Aluminium Dial With , Ss Internal, Dn 15 Gi Impulse Line With Three Way Cock. 12 A ) Pressure Guages ( 0 - 15 Kg / Cm2 ) 13 B ) Compound Guages ( +1 To -1 Kscg ) 14 Supply, Delivery And Storage At Site Of 80 Mm Dia , Thickness 5.4Mm And 80 Mm Dia 5.4 Mm Thick Ms Black Pipe Conforming To Is:3589 Gr.330 ( For Suction, Delivery & Delivery Header ) Along With Necessarybends, Fittings Viz. Flanges, Bolts, Nuts, Gaskets , Concentric Enlarger50 X 80 Mm Etc. As Reqd. To Make The Installation Complete In All Respect Andas Pernit. 15 Supply Delivery And Storage At Site Of Ultrasonic / Radartype Continuous Level Measuring Unit With Provision Of 4 To 20 Ma Analogue Signal, Indicator And Recorder For Continuous Level Monitoring As Well As 5 Nos. Relay Out Put For Sensing High, Low, Low - Low Level In Suction Sump As Per Specification Given In Nit. 16 Supply, Delivery And Storage At Site20 Mm Dia, G.Ipipes ( Medium Duty ) , Water Storage Pvc Tank , Bends, Sockets, Tees, Fittings, And Other Specials, Gaskets , Solenoide Valve , Gate Valve For Auto & Manual Operation Etc. As Reqd. To Make The Piping Arrangement Of Vacuum Pumpcomplete In All Respect As Pernit. ( For Priming Arrangement ) 17 Supply, Delivery And Storage At Site 2 Mm. Thick Crca Sheet Steel Enclosed Cubical Type Indoor Floor Mounted415 Volt Mccpanelhaving Required Feeders With Plc As Per Specification Given In Nit. 18 Supply, Delivery And Storage At Site 2 Mm. Thick Crca Sheet Steel Enclosed Cubical Type Indoor Wall Mounted415 Volt Power Distribution Board Having Required Feedersas Per Specification Given In Nit. 19 Supply, Delivery And Storage At Site 1.1 Kv Grade35 Mm2 3½Core Xlpe Insulated Cupper Armoured Cable As Per Technical Specification Of Nit. ( From Cut Out To Pdb Panel ) ) 20 Supply, Delivery And Storage At Site 1.1 Kv Grade50 Mm2 3½Core Xlpe Insulated Aluminiun Armoured Cable As Per Technical Specification Of Nit. ( For Pdb Panel To Mcc Panel ) 21 Supply, Delivery And Storage At Site 1.1 Kv Grade25 Sq.Mm 3½Core Xlpe Insulated Aluminiun Armoured Cable As Per Technical Specification Of Nit. ( For Voltage Stabilizer To Mcc Panel ) 22 Supply, Delivery And Storage At Site1.1 Kv Grade 6 Sq. Mm.3Core Xlpe Insulated Aluminiun Armoured Cable As Per Technical Specification Of Nit. ( Formcc Panel To Motor. ) 23 Supply, Delivery And Storage At Site1.1 Kv Grade 2.5 Sq. Mm.12Core Pvc Insulated Armoured Copper Controlcable As Per Technical Specification Of Nit. ( Formcc Panel To Actuator. ) 24 Supply, Delivery And Storage At Site1.1 Kv Grade 2.5 Sq. Mm.2Core Pvc Insulated Armoured Copper Controlcable As Per Technical Specification Of Nit. ( For Solenoid Valve Connection ) 25 Supply, Delivery And Storage At Site1.1 Kv Grade 4Sq. Mm.2Core Pvc Insulated Armoured Coppercable As Per Technical Specification Of Nit. ( For Vaccume Pump Connection ) 26 Earthing & Lightning Protection For Pump House And Electrical Installation As Per Iss And Ie Rules And As Per Technical Specification Of Nit. ( Earth Pit 2 Nos+ 2 L / A ) 27 Supply, Delivery At Site And Storeage Of Gi Perforated Cable Tray At Pump House For Laying Of Incoming & Outgoing Power And Control Cables To And From Mcc Panelhaving Proper M.S. Structural Support As Per Nit Specification And Direction Of Eic. 28 Supply Delivery At Site And Storage Of Illumination Arrangement Like Suitable Size Wire, Switch , Switch Board , Tube Light Fitting , Exhaust Fan , Ceilling Fan , Led Outdoor Fixturecomplete As Per Specification Of Nit. 29 Supply Delivery At Site And Storage Of Safety Equipment Like Suitable Capacity Fire Extinguisher , Sand Bucket , Fire Bracket, Rubber Mats, Shock Treatment Chart And First Aid Box, Chair , Table, 415 Volt Danger Board Complete As Per Specification Of Nit. 30 Supply Delivery At Site And Storage Of Suitable Capacity Power Correction Arrangement As Per Specification Of Nit. 31 Supply Delivery At Site And Storage Of Disinfection Arrangement With Flow Rate 100 Lph As Per Specification Of Nit. 32 Part-B 33 Installation Of All Items As Mentioned In Sl.No.1 To 15 & 23 To 28 ( Part-A ) Including Construction Of Pump Foundations, Pipe Supports, Valve Supports, Laying Of Cables With Necessary Jointing Materials, Earthing Arrangement Of Motors, Starters, Including Supply Of All Erection Items Viz. Rubber Gaskets, Nuts & Bolts Etc., Including Cost Ofwelding Etc. As Required For Complete Installation Including Making Slope Of Floor And Arrangement Of Removing Gland Leckage Wateras Per Hydraulic Standard & Ie Rules In Compliance With Specification Of Nitand Upto Entire Satisfaction Of Eic. 34 Painting Of The Installation ( Viz.Pumps, Valves, Pipe Lines Etc.By Two Coats Of Epoxy Paint ( Colour To Be Decided By Eic ) Over A Coat Of Primer As Per Nit Specifiaction & Direction Of Eic. 35 Testing & Commissioning Of The Entire Installation I.E.Pumps, Motors, Valves Etc. As In Part A ( Sl No. 1To 28 ) As Per Direction And To The Entire Satisfaction Of E.I.C. 36 Operation And Maintenance Of The Entire Installation In High Lift Pumping Stations On 24 Hrs. Basis Including Guarding For A Period Of 90 Days Are To Be Provided With Supply Of Skilled, Semi-Skilled And Un-Skilled Personnel Including Watch And Ward Personnel From The Date Of Commissioning. During Maintenance Period Supply Of All Consumable Materials Sundrys And Lubricants Are To Be Supplied. Charges Of Electrical Energy During Maintenance Period Will Be Born By The Department. 37 Supervision Charges For Electrical Installation By Licensed Electrician As Per Ie Rules, 1956 Read With Latest Amendments With Overhead Expenditures.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
West Bengal View Result →
28.
Defence #10169790 Price Bid
Tender For Procurement Of Tata Spare Parts, Tata Spares Part : , Clutch Releaser Brg , Assy Clutch Release Brg With Sleev , Oil Seal , Sliding Sleeve , Tapper Roller Bearing (Rear Hub Outer) , Tapper Roller Bearing (Rear Hub Outer) , Taper Roller Bearing Outer ( 70X 125 X33.250 ) , Taper Roller Bearing , Taper Roller Brg , Synchronising Ring With Sleeve 5Th Speed , Synchronising Ring (5Th Speed Gear) , Helical Gear 2Nd Speed , Helical Gear 4Th Speed , Steering Pump , Vane Pump , Clutch Release Bearing , Clutch Release Brg , Oil Seal (To Hubs Inner) , Coller Bushing 47.2 Mm Long , Shifting Sleeve , Rear Axle Shaft , Mainshaft , Hekicalgear3rd Speed , Rear Hub Greasing Kit , Synchronsing Sleeve4th And 5Th Speed , Element Air Cleaner(Primary)Sfc 410 Fltg , G/Box Housing Cover Frt Top , Synchronising Body 4Th And 5Th , Reverse Gear On Main Shaft , Counter Shaft , Gear Rear , Element Air Cleaner(Safety) , Assy Ball Joint Rh Thd , Assy Universal Joint (For Zf P/Strg) , Head Lub Oil Filter With Adopter , Assy Clutch Master Cylinder , Thermostat , Assy Auxiliary , Water Pump Assy , Pump Water , Kit Brake Lining Set Front (Std) , Core Cooler , Brake Drum Spigotted , Assy Stub Axle Std , Assy Drag Link , Pump Lucricating Oil , Power Stg Pump 80Bar (Rane) , Assy Ball Joint Lh Thd , Assy Clutch Master Cylinder , Drag Link Kit , Repair Kit Turbocharger , Set Of Brake Linings W/O Rivets(Wheel Set)Rear Std , Assy Universal Joint , Assy Crank Shaft , Assy Oil Filter (Purolator) , Housing Fly Wheel , Oil Seal , Oil Seal Valve Stem , Seal Valve Stem , Gear Flywheel Ring , Oil Seal (C R Seals) , Gear Fly Wheel Ring , Gear Fly Wheel Ring , Gear Fly Wheel Ring , Oil Seal , Oil Seal , Kit Oil Seal , Valve Guide Seal Exhaust(Chicago Rawhide) , Oil Seal (Hand Beake Shaft) , Oil Seal , Oil Seal ( Cr Seals ) , Oil Seal (Inner )135X170x15 , Concord Brg(Bimetal)Normal 1 , Synchronising Cone , Oil Seal(Outer ) 125X150x12 , Assy Ball Joint , Sealing Ring , Assy Housing Block , Gasket Therm Hsg Cyl Hd , Oil Seal Cam Shaft Rear (Cover) , Sealing Ring , Oil Seal , Seal O Ring (Big) , Shaft Seal , Gasket Exh Manifold Pipe , Gasket , Gasket Tube To Tc , Brake Lining Std , Oil Pump Drive Shaft , Repair Kit (Minor)M/C , Fulcrurn Pin , Fuel Line (Fuel Filter To Fip) , Fuel Flexible Pipe (From Fuel Filler To Fip) , Assy Refilling Container Complete , Gasket(Turbine Inlet) Sankar , Repair Kit Major Master Cylinder Consisting Of , Retainer Oil Seal Dana , Oil Sump Gasket , Fuel Line (Feed Pump To Fuel Filter) , Drive Gear , Oil Seal , Brake Lining Std , Major Repair Kit Clutch Booster 70 Dia , Drain Cock , Slave Cylinder , Gear Fly Wheel Ring , Pully (3 Grooved) , Water Pump Repair Kit , Sealing Ring , Water Pump Kit (Minor) , Kit Repair Water Pump , Sealing Ring , Set Of Brake Linings W/O Rivets(Wheel Set)Rear Rs I , Kit Brake Lining Set Front(R/Si) , Wheel Set Brake Lining Frt R/S Ii , Dual Brake Valve , Water Pump Assy , Water Pump Kit (Major) , Tube Injector Kit (1 2 3) , Fuel Line Nls Filter To F1 , Ball Joint Assy (Lowre) , Assy Tie Rod , Oil Seal , Assy Fuel Line , Tube Injector Kit(4 5 6) , Assy Hub Front , Assy Bkt Shac , Kit Lining Set(Rear)(R/Si)M/S Bil , Set Of Brake Linings W/O Riverts (Wheel Set) Front Std , Caliper Brake Rh W/Shim , Oil Sealinstallation Tool , Dual Brake Valve , Kit Caliper(With Piston) , Assy Fuel Filter ( Lucas) , Brake Drum(Front) , Wheel Set Brake Lining Frt R/S 1 , Assy Oil Pump(Shorter Version) , Assy Oil Filter Complete(Spin On 138 Ht) , Assy Exhaust Brake Unit , Kit Rear Lining Set (Std) , Brake Shoe Lining And Roller Assy , Assy Steering Wheel Without T Emblem , Wheel Cylinder Assy 50.8 Mm , Hand Brake Valve , Tie Rod End Rh , Assy Pressure Valve Cap (14Psi) , Front Brake Overhaul Kit Minor , Clutch Slave Cylinder , Assy Pressure Valve Cap (7Psi) , Thermostst(Caltherm 120Lph) , Oilseal , Thermostate(78 Sot Gasket Cover To Thermostate Hsg) , Seal Kit (Valve Sleeve) Comprises Of , Oil Seal(Crank Shaft Front) , Rack Pad Adjuster , Pressure Line 6Th Cyl , Seal O Ring (Small) , Oil Seal , Assy Cap , Oil Seal 39X57x9 , Washersealing , Oil Seal , `O` Ring , Side Seal(M.B.Cap Rear) , Sealing Ring Rubber , Rubber Seal (Seal Holder To Joint , Gasket (For Top Cover) , Gasket ( Water Pump ) , Gasket Water Pump Nls , Rear Axcel Shaft (Through Headned) , Gasket Water Pump Nls , Shifter Fork (Reverse) , Gear Speedometer Drive , Shifting Fork (For Second And Third Gear) , Selector And Shifter Shaft , Bush King Pin , Oil Seal , Oil Seal , Assygear Shifting Lever Knob , Reverse Indicator Switch , Reverse Light Switch , Shifter Fork (1/23/4 Speed) , Drive Shaft , Counter Shaft , Synchronising Ring (5Th Speed) , Shiffer Sleeve , Synchroring 5Th Speed , Gear Front , Needle Cage Double Row , Bearing Housing , Transmission Housing Cover Front , Gear Shift Lever Assy (With Bushes) , Magnetic Drain Plug , Bearing Ball , Thrust Washer , Taper Roller Bearing 92.075X50 8X24.6 (28580/28521) , Tappet Roller Brg For Counter Shaft (40X90x25.25) , Brg Taper Roller , Four Point Ball Bearing , Angular Contact Ball Bearing [Skf][100X45x25] , Taper Roller Bearing Inner 80X140x35.25) , Taper Roller Brg ( 95X145x39) M/S Abc , Tapper Roller Bearing (Pinion) (65X145x39.75) , Tapered Roller Brg(Hyp Pinion) , King Pin Lower , Bearing Cyl Roller , Cylinderical Roller Brg , Brg Taper Roller For Differantial , Bearing Cyl Roller (For Tail Pinion) , Cylindrical Roller Thrust Bearing 100X75x 7.5 , Cylinderical Roller Brg , Four Point Ball Bearing (100X45x25) , Pulleyfan , Tapered Roller Thrust Bearing Normal (72.6X38.65X21.43) , Assy Fly Wheel , Main Shaft (Thrust Brg Arrgmt) , Taper Roller Brg Outer , Assy Flywheel , Assy Fly Wheel , Assy Helical Gear (5Th Speed) , Ring Gear , 6 Pk 1060 El Epdm Belt Samsons , Ring Gear , Seal Oil , Hose Rubber ( From Engine Outlet) , Assy Cl Rel Brg(Self Centering) Texspin , Seal Injector , Needle 2X13.8 Br 11 Is 4217 , Ball Brg (6204 2Rsr C3) , Needle Bush , Srdg Brg 20 Bc 02Xee/47X14 6204 2 Rs , Spring Pin (Rear Spring) , Oil Seal(Crank Shaft Rear) , Bearing Needle Cage , Bushing Unboard Std , Brg Assy W/O Race , Stop Light Switch , Bush , Sre Bearing , Cylindrical Roller Bearing , V Belt Nls 6Gr 1316 Mm , Taper Roller Bearing , Rpm Meter 24V 552H M/S Minda , Bearing Wheel Hub Inner , Front Spring Shackle With Bush , Assy Drag Link , Cylindericalroller Bearing , Bearing Taper Roller (133.35 X 85.725 X 30.163) , Tapper Roller Bearing Rear Hub , Taper Roller Brg (100X445x27.25) (Skf) , Assy Radiator Pipe With Hose , Hose Engine To Radiator , Assy Spring Shackle Rear , Ball Bearing , Srdg Ball Bearing 42X20x12 60042 Zr , Roller Cage (Double Row) , Roller Cage (Double Row) , Roller Cage Single Row , Poly Vee Belt (6 Groove) , Needle Bearing (Input Shft ) , Cylindrical Roller Bearing(Drive Pinion) , Roller Ring , King Pin (Upper ) , Srdg Ball Bearing (Skf 62110) , Brg Needle , Taper Roller Brg (Skf) , Spring Pin , Roller Cage (Double Row) , Poly V Belt 6 Pk 1255 L(Samsons) , Ball Bearing , Rubber Bush , D G Ball Brg(6202-2Rs 1/C3 Ht 22B) , D.G Ball Brg.( 6203-2Rs/C3htb) , Pivot Bush , Assy Drive Shaft Rh Inner , Cylindrecal Roller 4X8 , Bush , Twin Gear Counter Shaft 2/3Speed , Sewling Ring Assy , Rubber Hanger , Kit Brg Strap Bolt Dana , Assy Shackle (Rear Sprg.) , Rubber Bush , Set Piston W/O Rings Gr A , Set Of Piston Ring Std , Reston Ring Set Std , Steel Ball 11Mm Iii , Cylinder Head Gasket(Mls)Reinz Euro Iii , Engine Gasket Kit Upper , Bearing Block , Bever/Pinion Differential , Gasketcylinder Head , Rubber Support Front , Rubber Bush , Gasket Cyl Head , Assy Hose , Hose Flexible , Gear Flywheel (138 Teeth Bolt Type) , Gasketvalve , Rubber Mould (Wind Screen ) , Gear Camshaft , Gasket(Cyl Hd Cover) , Gasket Head Cover , Shifter Finger , Shifter Finger , Spider Differtial , Shaft Speedometer Drive , Assy Combi Screw (To Cover Timing Gear Housing) , Set Ofcon.Rod Bearing R/S-I Consistingof Bearing Con Rod (0.25 Mm Oversize) , Brass Pad(2Per Fork) , Cover Push Rod , Cover Push Rod , Set Of Connecting Road Brg R/S Ii , Gasket (Cover To Thermostat Housing) , Gasket Cover (Rh) , Clamp Hose , Oil Pump Gear (Driven) , Gasket Gear Cover , Bolt M8x55 Is-1364 , Repair Kit For Pistonring , Sleeve Salvage/Liner , Set Of Main Bearing 0.25 Mm Over Size(R/S-I) Consisting Of Three Items. , Gasket Inlet Manifold Cover , Hose Flexible , Gasket , Closing Ring , Shim 0.16Mm Thick , Oil Catcher , Boot , Con Rod Bearing Set Std , Link Rod (W/O Ball Joints) , Stud , Bracket(On Cyl. Block) , Tube Oil Gauge , Lever Shut Off Plate , Slinger Oil , Bearing Assy , Gasket , Packing Ring , Bearing Bush Ce , Sealing Ring , Blinker Glass Rh , Cup Moulding , Adapter Filter Head , Banjo , Assy Control Shaft With Lever , Ring Valve Seat Std-1 , Feed Pump Plunger(Blue) , Lever & Peg Assy , Oil Seal , Hose Pump , Major Kit Wheel Cyl , Suction Valve Seat , Lamp Interior , Cover Locker Wier , Slector Shaft , U Clamp (Rh) , Screw , Oring Rack Pad Adjuster , Front Spring Leaf 10Th , Impeller , Reducing Nipple , Assy Turnindicator , Gasket For Inspection Cover , Brush Assy , Hose Back Leak (270 Mm Length) , Dips Stick Liquid , U Clamp (Lh) , Rubberhose , Banjo Bolt , Piston (Plunger) , Assy Pull Road (Exhaust Manifold Side) , Piston , Adapter Oil Filter , Bal Brg (Skf) (62X25x17) , Oil Seal , Pad Spring , Assy Pipe , Amplifier Relay , Assy Hose , Injection Plug , Seal Ring , Assy Air Filter , Connector Banjo , Spring Housing , Rubber Buffer , Sealingring , Butting Ring 3.2Mm Thick , Handle(Door Inner Without Electro Plating) , Delivery Valve Holder , Spanner Adjustable A-300-Is-6149-G-2 , Assy Tube , Idling Spg , Connection Water Outlet , Capsule(Mico) , Gear For Drive Shaft , Connector , Clutch Plate Steel , Bearing Bush(Int Bracket) , Fuel Gauge , Centre Pin , Gasket (Shift Cyl) , Brake Shoe , Mtg Bkt Top , Plunger Spring , Gasket , Gaskt (Betweenupper & Lower Half) , Compression Valve Seat , O Ring Worm Cover , Screw For Inspection Cover , Screw For Inspection Cover , Ring Spanner 8X 9 , Hazard Warning Switch (Pec) , Suction Pipe (Air Filter) , Gasket , Fexing Bolt , Gasket Turbine Outlet , Set Of Gasket Kit , Seal Ring (Mico) , Gasket , Pinion Spring , Brush Spring , Shim 0.10Mm , Bearing Ball , Delivery Spring Valve , Shim 0.12Mm Thick , Woodruf Key (On Cam Shaft) , Rubber Grommet (In Brackets) (Brake House) , Setof Con Rod Bearing Std , Set & Connecting Rod Bearing Std , Ring , O Ring , Clampv Band , Hex Collar Bolt Dicor Euro Iii , Bush Bonnet Hinge , Bracket , Gasket Ring , Gasket Lub Cooler , Bracket (On Timing , Oil Tray In Rear Housing , Clamp Lower , Asy Oil Separator , Assy Wiper Arm , Gasket , Hoseflexible , Hose Flexible , Hose Flexible , Hose Flexible , Hose Plain , Hose Plain , Valve Pressure Relife , Ring Spanner 8.0 24X27 , Valve Exhaust(Euro Iii)Evl , Hoseplain , Hose Plain , Cover Lower , Kit Insert Exhaust Valve , Needle Brg , Bush Con Rod , Bush Con Rod , Cover(Rear Hub) , Gasket (Intake Mani.Cum. Head Cover Ssl) , Slider , Gasket Filter Head , Threaded Ring , Hub Bolt , Insert Valve Exhaust , Insert Valve Intake , Support Camshaft , Assy Gasket Oil Sump , Wheel Mounting Bolts , Butting Ring 6.95Mm Thick , Valve Exhaust , Valve Exhaust , Gasket Gear Housing , Valve Intake , Dipstick , Gasketvalve Cover , Gasket Valve Cover , Valve Intake , Compression Spring , Snapring2.83Mm Thick , Snapring 2.68Mm Thick , Scraper Ring , Compression Spring , Gasket (Benco Talbros) , Kit Insert Inlet Valve , Washer Sealing , Carrier , Rod Push , Valve Exhaust , Cartridge , Gasket Rr Cover Adp Hsg , Synchronising Cone , Nut M 12X1.5 Is-1364(Mig Pad To Engine Cross Member Front) , Screw Hex Head Cap , Seal Valve Steam , Seal Valve Steam , Bush Rod , Oil Seal , Ring Retaining , Spring Seat , Stud For Timing Belt Tensioner , Spring (For Accord) , Sealing Ring , Shim 0.10Mm Thick , Pressure Spring(Rev Ind Switch) , Spring , Nut Hexagon Flanmge , Collet Valve , Shim 0.5 Mm Thick , Dowel Pin M10x16 , Bolt M8x35 Is 1364 , Wood Ruf Key 8X13 Is : 2294 , Gasket Cover To Crank Case , Gasket (Exhaust Elbow To Turbo Charge) , Nut Hexflange Head Cap , Pin Cotter , Circlip A 28X2 , Plunger , Hose(Vent Tube To Radiator) , Stud , Valve Guide Inlet Std 15 S7d , Adapter Filter Head , Hose Clip , Shim 0.80 Mm Thick , Dowel Pin (12Hbx30 Is 2393)(For Connecting Clutch Housing) , Felt Washer (Sludge D/Screw) , Washer , Hose Clip 16 , Rubber Buffer Rear , Sealing Washer(Injector 4 Sp Dicor) , Hose Plain , Gasket (Cover Front On Hsg) , T Connector , Locking Plate , Valve Guide Std (Exhaust) , Lock Nut , Screw Hex Flange Head Cap , Hex Bolt For Clutch Housing , Lock (For Threaded Ring) , Gasket Front Cover , Hose Clip Screw Type , Hose Clip 21 Ts 17669 , Bushing , Screw. Hex Flange Head Cap , Washer Plain , Gasketflange , Gasket (Cooling W/Line Thermostat Housing With Flange) , Gasket Flange , Spanner De 8 X10 , Gasket(Air Intake Elbow) , Adapter , Pin , Screw Hex Flange Head Cap , Seal O Ring , Seal O Ring , Ring Retaining , Retainer Valve Spring , Bracket Lifting Engine Rear , Assy Hose (B1) , Thrust Washer (Cam Shaft To Cyl Block) , Nut M12x1.5 Is 1364 , Seal O Ring , Elbow Diff Lock Lines Tcone Below Substructur To Diff Lock , Stud Bm12x55 Is 1862 , Valve Spring(Inner) , Brace Fuel Pump , Stud Bolt(For Mtg Cyl Hd) , Plug Thrreaded , Washer Sealing , Ball End , Valve Spring , Hose Clamp Tb 54 , Hoseclamp Tb36 , Sleeve (For Cyl Block) , Hose Scoop To Tc , Sealrectangular Ring , Main Bearing Cap Bolt , Hose Tc Re Pipe To Sump , Vacuum And Pressure Cap , Valve Lock Half , Retainer Valve Spring , Screw Connecting Rod , Connecting Rod Bolt(Fully Threaded) , Clamp Hose , Hose (Scope To Tc) , Set Thrust Washer (Upper/Lower) , Nozzle Piston Cooling , Gasket , Connector Engine Vent , Seal O Ring , Hose (20X110) , Valve Guide Exhaust(Std) , Cover Access , Clamp Hose , Rubber Hose , Link Rod (224 Long ) , Seal Rectangular Ring , Rubber Hose (Overflow Line To Joint) , Clip , Thrust Spacer , Valve Seat Ring Exhaust Normal-1 , Adjusting Screw , Tube , Connector Female , Spacer Ring , Tube Fuel Supply , Assy Wheel Nut , Tube Fuel Supply , Tube Fuel Supply , Tube Oil Filter , Nuthexagon Flange , Hose Therm Bypass Pipe , Connecting Road Bearing Std 1 , Rubber Hose Moulded (Cover To Pipe) , Assy Engine Mtg Head Rear , Cylinder Liner , Rubber Hose ( Water Fill Pipe ) , Screw Banjo Connector M 10X1 X19 , Collar Screw , Dipstick , Ball Pin A 10 , Hose Rubber( Radiator Water Pump ) , Tube Oil Guage , Rubber Hose (Radiator To Engine) , Hose , Rubber Hose (Radiator To Eng) , Spacer , Rubber Hose Engine Vent , Dipstick , Sealing Ring (Mico) , Cover Valve , Hose Plain , Hose Plain , Gasket Rear Cover , Banjo Connector , Oil Seal Camshaft Front , Assy Throtle Valve , Cap Rubber Protective (On Gear Box Top) , Guard Plate 2.90Mm Thick , Valve Cover , Assy Hose , Hex Screw M6x20 Is 1364 P2 88 Ss 8451 , Hex Screw M8x25 Is 1364 P2 8.8 Ss 84 , Rubber Hose , Assy Hose , Tube Fuel Supply From Filter To Fip , Screw M16x1.5X40 , Hose Assy , Asd , Banjo Bolt , Liner (Ipl) , Hose Clamp Tb 126 , Fuse 50A Light Blue , Over Flow Valve , Centre Pin , Assy Bracket Rh(Eng Mount Rear On Frame) , Hoseelbow , Hose Plain , Assy High Pressure Hose , Breakhose 550 Mm Long , Hose (Pipe To Pipe) , Cover Intake Manifold , Assy Hose , Assy Pull Cable Engine , Engine Screw Driver 1.2 X8 X150 , Hose (Radiator Top) , Compression Ring , Rubber Hose , Hose(Radiator To Water Pump) , Rubberhose( Engine To Radiator ) , Spring Valve , Hose Flexible , Hose Flexible , Hose Flexible , Oil Seal (For Hub) , Thrust Washer Lower Std(Menon) , Repair Kit For Piston Consisting Of- Sixitem , Spanner For Wheel Nuts , Liquid Gasket , Hose Plain , Drive Square , Assy Bracket Top , Assy Timing Belt Tensioner Complete , Rubber Hose (Radiator To Thermostat , Rubber Elbow ( 12 Id X150x 150 ) , Set Of Main Bearing 0.75Mm Over Size (Rs-Iii) Consisting Of Three Items , Radiator Hose Outlet , Assy Hose , Hose Assy , Decarburising Gasket Subkit , Hose Straight , Spacer Pilot Taper Roller Bearing Of Main Shaft , Gasket Cylinder Head Std 0.15Mm Over Size , Nut For Pulley , Hose Aux Tank To Water Fill Pipe , Assy Exhaust Pipe(Manifold) , Bearing Set R/S 11 , Eng Gasket Subkit , Housing Thermostat , 4X4 Shaft Joint Assy , Engine Overhaul Gasket Kit Tc , Engine Gasket Kit Lower , Wrench For Hub Lock Nut , Gasket Exh Manifold , Connection Turbo Oil Drain , Cover Gear , Clamp Hose , Bearing Set R/Si , Major Repair Kit Consisting Of -16 Items , Rubber Hose(Radiator To Engine) , Stud , Platecylinder Block Stiffner( Bed Plate ) , Plate Cyl Block Stiffner(Bed Plate) , Pin Piston , Clamp Hose , Hose Elbow , Hose Elbow , Exhaust Valve , Assy Hose , Poly V Belt 6 Pk 1245 (Samsons) , Engine Overhaul Seal Kit Bs Iii , Set Of Con Rod Bearing R/S Iii Consisting Of , Set Of Con Rod Bearing R/S-Iii , Set Conrod Brg Normal , Spacer Fan , Assy Pump From Stg Pump To Stg G Box , U Clamp Rear Spring , Reducer Hose(Ontc) , Tube Oil Filler , Bolt Connecting Rod , Assy Hose , U Clamp , Rubber Hose , Mounting Pad Rear , Pin Timing , Poly V Belt(6 Pk 1360 El) , Poly V Belt(1360 Svl A/C Fan Samsons) , Rubber Hose Engine To Radiator Inlet , Capfiller , Manifold Fuel , Rubber Hose , Spacer Fan , Thrust Washer 2.05Mm Thick , Repair Kit Quick Release Valve , Compressionring , Braceair Compressor , Hose Clamp Tb 38 , Gasket , Flat Seal Ring (Mico) , Hose Int Cool Pipe Bottom , Hose Plain , Piston Pin , Connection Water Inlet , Valve Seat Ring Inlet Normal , Gasket , Rubber Hose , Thrust Washer 2.00 Mm Thick , Spherical Washer , Leakage Oil Line , Hose ( Radiator To Water Pump ) , Alternator (12V 55 Amp) , Assy Oil Ring Iii(G) , Pipe(Tc To Ic) , Screw Hex Head Cap M14x2.0X119 , Hose (102 1Dx120l) , Torqure Support Front , Rubber Hose (Cooling Water Line To Thermostar) , Assy Rubber Stoper (Bump) , Tube Fuel Supply , Tube Fuel Supply , 1St 3Rd 5Th 7Th 9Th And 11Th Rocker Arm Left With Bushing , 2Nd 4Th 6Th 8Th 10 & 12Th Rocker Arm Right With Bushing , 1St 3Rd 5Th 7Th 9Th 11Th Rocker Arm Left With Bushing , 2Nd 4Th 6Th 8Th 10Th 12Throcker Arm Right W/Bush , Screw M12x1.5X24 Banjo Connector , Assy P/Stg Crimp Pipe Stg G.B To Tank , Flat Collar Nut , Plunger Pressure Regulator , Bell End Amb10 Ts15624 , Gasket , Seal Rectangular Ring , Hub Bolt Front (M 20) , Plate Cover , Valve , Banjo Bolt , Thrust Washer (Idler Arm) , Intake Valve , Spring Valve , Spring Valve , Gasket , Gasket (Fip To Support) , Hose(To Assy Oil Separator , Sealing Ring Half (Set Of 2) , Bolt M12x1.5X40 , Dial Gauge Attachment , Ring Retaining , Clamping Nut , Seal Rectangular Ring , Seal Rectangular Ring , Plug Pipe , Assy Hose (To Air Pressure Gauge) , Spring (Brake Return) , Bracket Lifting Engine , Centre Bolt M12x187x11 Is 9484 , Locking Ring S10 Ts 15624 , Seal Benjo Connector 6.2 Mm , Plate Locking , Bolt M18x1.5X55 , Hose , Thrust Washer , Spring Compression , Dust Valve , Dust Valve , Center Bolt M 10 X75 X9 , Stood Bm12x40is1862 , Gasket Turbocharger , Gasket Turbo Charger , Teefemale Branch , Spacer Pump Support , Banjo Bolt , Bolt M18x1.5X65 , Hallow Screw , Housing Timing Pin , Brace Fuel Pump , Seal `O`Ring , Plug Pipe , Gasket , Tube Turbo Oil Drain , Seal O Ring , Bracealternator , Seal Rectangular Ring , Seal Rectangular Ring , Hose(Breather) , Thrust Washer Upper Std(Menon) , Retorn Spring , Main Bearing Upper Normal , Main Bearing Lower Normal , Spacer , Bolt , Sealing Washer 18X22 Is-3175 , Bush-Connecting Rod , Stud , Screw Twelve Point Cap M10x1.5X35 , Gasket(For Support) , Rubber Hose (Assy Pipe Elbow To Assy Pipe) , Rubber Hose (Thermostate Cover Yo Radiator) , Gasket , Gasket Oil Drain , Screw Twelve Point Cap , Rubber Mounting (Bottom) , Plug Expension , Screw Banjo Connector , Screw Banjo Connector M 12X1.5X24 , Hose , Hose Back Leak(35 Mm Length) , Screw Hexflange Head Cap M8x1.25X90 , Lock Retainer Valve Spring , Connecting Bushing(Unbored) , Seal Grommet , Stud Bm12x80 Is 1862 , Screw Hex Head Cap , Shim 0.40 Mm Thick , Screwhex Flange Head Cap , Pipe Union Bolt 8M12x1.5 Ts 16405 , Spring Compression , Pole Screw , Connecting Nipple Inner , Screwbanjo Connector , Gasket Timing Gear Housing , Clip Hose , Plug Expansion , Valve Spring Retainer , Lock Retainer Valve Spring , Seal O Ring , Hose Back Leak(60 Mm Length) , Assy Combi Screw , Nut , Anti Rattle Clip , Clip , Shim(2.40) , Hose Clip 17.Ts 17669 , Hose Back Leak(35 Mm Length) , Sph.Washer 8.4 Is 4297 Ss 8400 , Rubber Hose (6 Idx80 Long) , Dowel Ring M16x10 , Screw Round Head Cap M5x0.8X17 , Plug Expansion , Sealing Washer , Clamp , Dowel Sleeve (For Starter) , Wheel Bolt 45842-1 , Screw M 12X35 Is 1364 , Tappet Valve , Screw Hexflang , Seal Rectangular Ring , Screw Hex Flange Head Cap , Screw M 10X25 Is 1364 , Spacer Washer 0.2 Mm Thick , Hex Screw M8x18 Is 1364 P2 8.8 Ss 84 , Screwhex Flange Head Cap , Nut(Connecting Rod) , Rubber Bush , Seal Rectangular Ring , Dowel Ring , Screw Hexflange Head Cap , Screw , Gasket Connection , Connecting Nipple Iner , Bolt M10 X 85 Is 1364 , Screw Hexhead Cap , Washer Plain 1.65 Thick , Hose Clip 30A Is 4762 , Valve Spg Pressure And Suction Valve , Shim 0.05 Mm Thick , Bolt M6x60 Is1364 , Shim 0.20Mm Thick , Spacer Washer 0.1 Mm Thick , Key Plain Woddruff , Spring Washer B12 Is 3063(Mtg Pad To Eng Cross Member F) , Bright Washer 6.4 Is 2016 St Ss 8451 , Pin Cylindrical 8X16 Is 2393 , Spring Washer B6 Is 3063 Ss 8451 8C , Screw M6x12 Br1364 , Roller 4X12 11 Js 4217 , Shim 0.1Mm Thk , Snap Ring 2.68Mm Thk , Hose Clamp(50 Dia)(Jupitor) , Screw Connecting Rod Mj11x1.25X59 , Oil Seal , Washerplain , Isolatornoise , Gasketexhaust Main Fold , Isolator Noise , Screwflange Head Cap , Assy Pipe(Sig Pump To Power Stg Tank) , Kit Brake Lining Front Std (Per Axle ) , Assy 228 Dia Clpressure Plate , Gasket Connection , Cap , Washing Sealing (1/2) , Bushing(Oversize For No 1 Bore) , Eng Overhaul Gasket + Seal , Minor Repair Kit Consisting Of -8 Items , Valve Cone Half , Plugexpansion , Bush , Pump Water , Screw Plug , Plug Expansion , Gasket , Collet Valve , Valve Kit , Cartridge , Drain Valvewater Separator , Filter Assy , Assy Clutch Pressure Plate 310Mm Dia) , Assy Clutch Pressure Plate , Strainer Fuel , V Belt (1325 Mm) , Cl. Cover Assy.310 Dia-Luk India (Ph-Iii) , Strainerfuel , Straines Fuel , Pump Water , Assy Rubber Support Rear , Guide Valve Stem Inlet , Sealing Washer 16X20 Is - 3175 , Gasket Cap Cyl Hd Cover Tc , Valve Guide Seal , Sprocket(On Crankshaft) , Minor Repair Kit Cylinder Head , Cap Main Brg , Mandrel For Clutch Plate Alignment , Hand Priming Pump , Pipeair Inlet , Drift For Installing Spigot Bearing In Camshaft , Drift For Crank Shaft Rear Oil Seal , Major Reair Kit , Drift For Outer Race Of Taper Roller Bearing Of Drive And Main Shaft , Cover Air Compressor , Head Fuel Filter (Bottom) , Drift For Removal Of Liners , Drift For Removal Of Exhaust Valve Guides And Installation , Engine Overhaul Gasket Kit Tc Bs Iii , Set Of Bare Piston (Rs Ii ) , Piston , Eng O/H Gasket Kit , Puller For Revarse Shaft , Puller For Reverse Idler Shaft , Handle To Be Used With Drift , Drift For Oil Seal , Drift For Installation Of Oil Seal Front Cover , Bearing Set Upper And Lowerr/S 11(Binetal) , Drift For Crank Shaft Oil Seal , Valve Spring(Outer) , Support , Assy Adaptor For Fip Timing Checking(Mico) , Valve Inlet(Euro Iii)Evl , Drift For Installing And Removal Of Con Rod Bushes , Support Engine Suspension Front , Hand Priming Pump , Gasket(Push Rod Chamber Cover) , Set Thrust Washer U/L Std(Menon) , Tube Dip Stick , Drift For Installation Of Water Pump Bearing Outer Race , Vacuum Indicator , Valve Seat Ring Inlet(Cng) Normal , Gasket , Gasket (Cylinder Head Cover) , Guide Valve Stem Exhaust , Assy Timing Belt Idler , Collar Bushing 47.6 Mm Long , Release Lever Kit , Tab Washer(Mico) , Bush , Cartridge , Filter Fuel , Steering Pump(Direct Drive) , Steering Pump ( Direct Drive ) , Auto Slake Adjuster Straight , Sub Assy Clutch Housing , Assy Radiator Complete , Assy Radiator (Banco) , Assy Radiator Complete , Inter Cooler Tubular Type , Cartridge Lub Oil Filter , Assy Radiator Complete , Reservoir Viso F 27/4 , Caliper Brake Lh W/Shim , Clutch Release Yoke , Assy Steering Oil Reservoir , Filter Element Safety , Separator Fuel Water(Cartridge) , Cartridge Lub Oil Filter , Assy U.J. Steering , Manifoldexhaust , Pressure Cap , Return Spring(Brake Shoe) , Assy Centre Brg Bracket Greasable , Sleeve Wear (Rear) , Sleeve Wear(Front) , Connector Oilsection , Damper Vibration , Assy Pull Cable , Rubber Housing , Speedo Cable (Jis) 4300 Lg , Speedo Cable 3.2 Dia 4300 Mm Long , Speedo Cable 3.2 Dia 4300 Mm Long , Assy Relly Cable Eng Stop , Rubber Buffer(Upper) , Gasket(Carrier) , Rexehe Bellow , Pull Cable Accelerator , Release Lever Service Kit , Gasket Set , Assy Outer Handle Rh , Assy Outer Handle Lh , Stud,Camshaft Bearing Caps , Assy Accl Stopper , Bush (Stay Rod) , Gasket(In Between Cover To Hub) , Gasket , Gasket Cover Plate , Rubber Buffer(Radiator To Cab Bracket) , Delrin Bush , Gasket , Gasket , Prefilter Seive , Spanner Deac 9X11 , Hose(Radiator Pipe To Engine) , Gasket For Feed Pump , Gasket , Centre Bolt M12x246x11 Is 9484 , Rubber Bellow(On Release Fork) , Thin Castle Nut M 32X1.5 , Assy Engine Mount(Rear) , Assy Connecting Line , Door Handle Inner , Handle (Lh) , Assy Cap Radiator , Nut M18x1.5 (Is 1364) , Assy Wiper Arm , Head Fuel , Adaptor For Oil Pressure Transducer , Pipe (Engine To Radiator) , Assy Support Arm , Minor Repair Kit Clutch Booster 70 Dia , Bolt M12x1.5X45 Is 1364(Assy Support Towing Hook To End Cross Member) , Assy Refilling Container , Assy Sunvisor Rh , Assy Sunvisor Lh , Assy Hose , Assy Precleaner , Service Kit Minor Rear , Assy 228 Dia Clutch Cover Luk India , Element (Primary) , W/Cyl Assy 26.99 Dia M/S Bil 2966568 , Steering Spindle(Bottom) , Kit Pad (Consisting Of 4 Pads) , Steering Spindle Top , Tie Rod End Lh , Piston Rack Seal Kit , Assy Radiator , Cross Universal Joint , Kit Brake Lining Frt O/S I (Frtrear) , Brake Fluid Reservoir , O/S Hub Assy , Assy Fuel Pressure Line ( 1 & 2) , Assy 228 Dia Driven Plate (Wad) Luk India , Rear Brake Chamber/Acuator Assy , Trailer Control Valve , Minor Kit Wheel Cyl , Assy Hub Front , Kit Automatic Slack Adjuster , Cylinder Head , Assy Radiator , Spindle Wheel Bearing , Clutch Disc Repair Kit , Assy Air Filter , Assy Power Stg Gaer Box , Hand Brake Valve(Voss) , Kit Lining Set , Assy Steering Column Support , Assy Radiator Complete , Roller , Break Auide Container , Assy Oil Cooler , Clutch Disc 228 Dia , Pad Assy , Speedo Cable ( Jis) 3000 Mm , Return Spg , Gasket (Gear Box Hsg Cover Rear) , Service Kit Cam Shaft (Rear) , Assy Master Cylinder (38.1X75 Stroke) , Repair Kit For Clutch Disc , Mounting Pin ( Lower)) , Major Repair Kit For M/Cyl , Seal Kit (Trunior) Comprises Of , Repair Kit Minor Clutch M/Cyl , Gasket (Between Rr Axle & Cover) , Tube( On Rank Case) , Assy Tube , Assy Inner Handle Rh , Gasket , Assy Guide Channel Rh , Assy Guide Channel Lh , Spanner De 13 X 16 , Assy Rubber Mounting Top , Gasket (Hub) , Assy Spacer Block Complete , Assy Pull Cableaccelerator , Spacer Lh , Spring Brake Shoe Return , Mud Flap Outer Rh Wheels , Gasket , Link Rod (1004 Long ) , Pressure Spring Complete , Bush Fulerum Pin , Gasket (Coveer Gear Box Hsg Rear) , Assy Gear Shift Lever Knob (6 Speed) , Flange Gasket , First Aid Kit , Gasket , Kit (Cam Adjuster) , Rubber Cover , Security Ring , Rubber Buffer(Radiator Frame Mounting) , Reflex Reflector , Grease Nipple , Gaskrt (Front Cover Upper) , Assy Propeller Shaft Reaar (From Aux Gear Box To Per Axle) , Gear Box Housing , Gasket To Front Locking Cover , Shifting Fork (For First Gear) , U J Kit Assy , Engaging Gear (Reverse) , Gasket (In Between Over To Hub) , Gasket Push Rod Cover , Driven Shaft , Assy Winding Regulator [Rh] , Assy Winding Regulator [Lh] , Wind Shield Glass (Single Piece ) , Air Filter Element Tc , Glow Plug , Assy Cyl Head , Pump Fuel Transfer , Camshaft , Cam Shaft , Housing Gear , Seal Oil , Set Of Bare Piston R/S-I Consisting Of -Piston Pin Pistonring Retaining , Set Of Bare Piston R/S 1 , Cyl Head Gasket , Fuse 20A Yellow , Safety Cartridge , Side Indi . Lamp Lh , Side Indi . Lamp Rh , Lamp H4 12V 60/55W For Head Lamp , Lamp H4 12V 60/55W , Assy Blinkerlamp Rh , Assy Horn (100 Dia) 12V Low Tone Padmini , Starter Push Button , Assy Rear Shock Absorber , Water Temp Guage , Crank Shaft Gear , Drift For Installation Of Taper Roller Bearing , Assy Nozzle Holder , Assy Connecting Rod W/O Brg Shells , Puller For Front Wheel Hub Outer Bearing Outer Race , Fuel Pump Timing Tool (Extension) , Puller For Coupling Flange , Connecting Rod With Serreted (W/O Brg) , Puller For Helical Gear Of Oil Pump , Puller For Taper Roller Brg Drive Shaft , Drift Installation Of Taper Roller Bearing Of Main Shaft (Inner Race) , Assy Fuel Rail(Delphi) , Puller For Pilot Taper Roller Brg Main Shaft , Angle Indexing Tool , Assy Feed Pump , Fuel Lift Pump , Fuel Liftg Pump , Alternate With Pulley 90 Dia 35 Amp , Main Fold Exhaust , Asm Motor , Puller For Needle Roller Bearingsoil Seal And Spacer , Battery Cable Positive , Release Travel Setting Gauge , Assy Fuel Heater , Drift For Installation Of Liners , Assy Front Sprg , Injector Assy , 8 Ton Hydraulic Jack With Handle And Spacer Block , Fuel Feed Pump , T Map Sensor , Pivot Bush Frt Suspn , Puller , Drive Gear Fip , Pinion With Bearing [Steel] , Assy Rlease Cable Complete L H , Assy Blinker Lamp Lh , Assy Wiper Blade , Engaging Ring (Reverse Speed) , Shifter Finger , Assy Drive Shaf Lh Inner , Assy Gear 2Nd Stage , Synchronysing Sleeve (2Nd /3Rd) , Wiper Blade , Spacer Ring 7.76 Mm , Kit For Spare Bulb , Fuse 25A Natural , Wiper Motor 24V 17W(2 Speed) , Ring Pin (Std) , Locking Wire , Wind Screen Glass ( Laminated ) , Drive Shaft With Oil Seal Ring , Shifter Fork Upper , Fuse 10A Red , Assy Drive Shaft Outer , Wind Shield Glass , Assy Padding Door Lh , Assy Padding Door Rh , Assy Window Regulator Lh , Assy Window Regulator Rh , Assy Wiper Blade , Assy Coupling Flange (Assy Cover To Bracking Housing , Fuse 5A Light Brown , Shifting Fork For Reverse Gear , Door Glass Lh , Door Glass Rh , Shifting Lever , Butting Ring 7.30 Mm Thick , Rear View Mirror , Brg Wheel Hub Outer , Handle Outer Lh , Assy Rear View Mirror Outer Rh , Assy Rear View Mirror Outer (Lh) , Assy Lock Complete Rh , Assy Lock Complete Lh , Oil Pressure Gauge , Oil Pressure Gauge , Leaf 8Th(Lh) , Terminal Positive , Needle Bearing (Roller Shaft) , Leaf 7Th , Thrust Collar , Rubber Bellow ( Air Filter To Assy Pipe) , Shaft Water Pump , Bal Bearing (85X45x19)(Skf) , Sre Ball Bearing , Terminal Positive , Brush Set , Suction Valve Cap , Leaf 10Th , Nozzle , Pump Element , Air Filter Safety , Worm Adjustercover , Pivot Pin , Moulded Cover , Hoseair Intake , Insulator , Regulator And Brush Set , Rubber Hose (Due To Air Filter) , Assy Reserve Tank ( Aux Water Tank ) , De Bracket , Brake Shoe Rear With Brake Lining 10.3 Mm Thick Std , Plunger , Shifter Fork (1St/Rev) , Heat Sink Assy +Ve , Assy Control Mounting Bracket With Tube , Aux Water Tank Cover , Statar Assy , R P M Meter , Lead Assy Negative , Kit For Cooling Water Thermostat Consisting Of-Six Items , High Press Hose P/S Pump To Gb , Rpm Meter , Bearing Housing , Hose (Radiator To Water Pump ) , Cross Member Rear (Eng) , Clutch Plate Brass , Piston Rack Kit 80 Bar , Clutch Assembly , Slip Ring Assy , Assy Head Lamp (Lh) , Axle Shaft Gear , Transmission Housing , Assy Air Filter , Starter Motor(Lucas Tvs) , Assy Propeller Shaft Rear ( Aux Gear Box To Rear Axle ) , Armature Assy , Pulley , Leaf 5Th , Kit For Clutch (Diaphram) Consisting Of- Three Items , Assy Propeller Shaft Ft Complete , Armature Assy , Kit For Pressure Spring , Air Filter Primary , Assy Radiator Complete , Front Spring Assy Lh , Rotor Assy , Kit Fornozzle Holder Consisting Of -Two Items , Assy Propeller Shaft Rear Comp , Injector , Injector , Kit Connecting Rod Consisting Of - Four Items , Starter Motor 35M 127 (M/S Ltvs) , Solonid Switch , Kit For Cylinder Head & Cover Consisting Of- Thirteen Items , Spring Fixture , Wiring Harness Main , Assydistributor Pump , Assy Fip Complete , Clutch Housing (High Prdie Casting) , Assy Radiator , Fuel Injection Pump , Pump Fuel Injection (125 Hp) , Kit For Water Pump Consisting Of- Thirteen Items , Kit For Steering Gear Pump Mounting & Belt Adjustment Consisting Of-Four Items , Armature , Assy Hub With Stud & Hub Hole (W/O Brg) , Transfer Case Housing , Kit For Main Bearing Consisting Of - Eight Items , Fuel Injection Pump With Governor Feed Pump W/O Inj Timber , Rotor , Solenoid Switch , Sub Assy Clutch Housing , Ce Bracket Assy , Assy Propeller Shaft With Centre Bearing , Kit For Clutch Housing Consisting Of- Eighteen Items , Assy Propeller Shaft ( Gear Box Aux Gear Box ) , Assy Propeller Shaft ( Aux Gear Box To Front Axle ) , Glass Rh , Assy Rear Spring With Aux Spring , Assy First Leaf With Bush , Spray Fluid Refill Can , Piston Ring Expander , Cover , Speedometer (Ratio/0 80) , Brake Drum Rear , Rpm Meter 24V , Assy Head Lamp (Rh) , Drift For Outer Race Of Tapper Roller Brg , C E Shield With Bearing , Rectifier , Assy Aux Water Tank , Air Filter With Sound Deadening Pads , Fd Coil Assy , D E Bearing , Ball Bearing , Heat Sink Assy -Ve , Release Lever Rep Kit (Major) , Sre Bracket , Speedo Meter , Field Coil Auxiliary , Leaf 9Th , Pressure Control Valve , Fan , Locking Bolt , Pumpncartridge Kit Consisting Of -Six Items , Spanner For Crank Shaft , Regulator , Leaf 5Th (Rh & Lh) , Assy Hose With O Ring(Aspiration) , Element , Element , Terminal Negative , Speedometer 1.0.825 , Convoy Lamp , Air Pressure Guage , Leaf 10Th , Oil Pressure Guage , Assy Hose , Major Repair Kit , Assy Bazzle Rh , Leaf 11Th , Clutch Pressure Plate , Hub (Water Pump) , Oil Catcher (Rear Brk Drum Hub) , Assy Wiper Blade , Assy Handle With Out Lock , Wiper Blade Front (Co Driver Side) , Door Lock Front Rh , Dr Square Tmg Belt Tensr , Set Mb Shell(Upper/Lower Normal) , Go Nogo Gauge For Exhaust Valve Guides , Set Piston Rings Std , Holder For Coupling Flange , Extender Timing Pin , High Temp Buzzer Unit 12V , Wiper Arm , Assy Cable Complete , Rubber Moulding Wind Shield , Assy Suction Tube With Strainer , Belt `V` Ribbed , Fan Shroud , Air Pressure Gauge M/S Minda , Assy Hinge Top Rh (Door) , Assy Exhaust Pipe , Doorlock Front Lh , Assy Mudflap Rear , Assy Silencer With Pipe , Pipe To Ic To Engine Turbo Apriated , Engine Mounting Bracket Attachment(To Be Used With Eng Stand Pt No 2573 5890 2401) , Rubber Mould (Rear Window) , Mudguard Rh , Assy Bracket(Rh) Slave Cylinder Mounting , Glass Pane Rear Window , Assy Engine Hood Complete , Assy Propeller Shaft Rear (From Aux. Gb To Rear Axle) , Mudguard Lh , Assy Joint Cross Left , Rubber Moulding (Lh) , Assy Propeller Shaft Front (From Gear Boxto Auxgear Box) , Air Pressure Gauge , Assy Prop Shaft W/Centrebearing Front ( Length 90X1586 ) , Assy Propeller Shaft Front ( From Aux. Gbto Frt Axle) , Assy Propeller Shaft , Repair Kit For Accesories Wiper , Assy Propeller Shaft Front ( Aux Gear Box To Front Axle ) , Assy Intermediate Spindle , Assy Prop Shaft Rear Complete (Length 90X1154 ) , Assy Prop Shaft W/ Centre Bearing Middle (Length 90X808 ) , Propeller Shaft Front , Engine Bearing Tool , Glass Lh , Supporting Sleeve Right , Assy Silencer With Tail Pipe , Assy Propeller Shaft With Centre Brg , Speedometer Electronic (0 80 0 100)Minda , Assy Cable Complete , Supporting Sleeve Lh , Assy Cover Side Lh , Assy Pre Silencer , Assembly Suction Jack With 3 Pcs Handle , Assy Sealing Mould Rh (Outer) , Assy Bazzle Lh , Wipper Controller Ed , Assy Rear View Mirror Out Side , Wiper Timer 24V , Assy Sealing Mould Lh (Outer) , Cross , Electronic Speedometer , Assy Lock Lh , Assy Eng Mount Front Lh , Assy Eng Mount Front Rh , Assy Wiper Blade , Side Cover Gasket , Assy Wiper Blade , Shifter Shaft , Suction Hose Complete , Assy Lock Rh , Speed Sensor 12/24V (8 Pulse) Espeedo , Tappet Removal Tool Kit , Drift For Installing Neddle Roller Brg In Top Cover , Ball Bearing , Ball Bearing , Bush (Idler Arm) , Assy Air Filter , Seperator Fuel Water , Assy Water Pump(M/S Autolec Industries) , Cross Assy , Air Filter Element Safety , Filter Assy , Minorkit Caliper Kb X280 , Filter Wrench , Clutch Housing Lever Part , Assy Twin Pot Caliper Lh Brakes India , Housing , Assy Prop Shaft Complete (Front) , Assy Rear Brake Actuator (Scl) , Assy Radiator(Plastic Tank 560 Core) , Repair Kit (Major) Tmc B1 , Assy Wheel Cyl , Sleeve (Slack Adj End) , Repair Kit For Slane Cylinder , Repair Kit Minor Slave Cyl , Assy Fuel Filter , Oil Filter Cartridge , Clutch Master Cylinder (19.05 Dia) , Slack Adjuster , Assy Clutch Slave Cyl , Clutch Slave Cylinder , Assy Clutch Master Cylinder , Timing Belt(136 Teeth) , Fip Gear(Reduced Module) , Connecting Rod Brg Set R/S-I , Puller , Set Back Leak Hoses , Dial Indicator Assy And Sleeve , Drift For Installing Crankshaft Gear , Set Piston(4 Each) , Set Piston Rings Std , Box Spanner 27 Af , Kit For Oil Separator Consisting Of - Four Items , Inj Puller , Reamer For New Inlet Valve Guides 10 Dia , Ring Gear , Vibration Damper Lock , Set Ofbare Piston Std Consisting Ofthree Items , Set Of Bare Piston Std , Pressure Plate And Needle Roller Service Kit , Master Cylinder (Bi) , Assy Clutch Booster Dia 70 , Assy Raditor Tayatoyo , Assy Aux Water Tank , Cartridge Lub.Oil Filter , Fan Engine With Viscous , Assy Connecting Rod W/O Bearing Shells , Assy Cross Kit , Gasket Flange Exhaust Pipe , Repair Kit(Minor) Clutch Sleev Cylinder , Assy Handle (For Window Regulator) , Thermostat (78 Set) , Flasher Kit (Electronic) , Major Cliper Kbx281 , Major Kit Slave Cylinder , Assy Hp Line (Rail To Injector No 3) , Air Cylinder (Sundarm Cloxton) , Accelerator Cable , Assy Coupling Flange , Desiccant Cartridge , P Way System Protection Valve , Assy Tandem M/Cylinder , Assy Wheel Cylinder 44.45 Mm Dia , Assy Twin Pot Caliper Rh Brakes India , Master Cylinder (Bi) , Vane Pump New (Steering) , Steering Pump , Assy Spring Brake Actuator Type 16/56 , Assy Tie Rod , Universal Joint Yoke , Air Filter Assy , Brake Fluid Container , Drying And Distributor Unit , Assy Master Cylinder(Bi) , Bracket Belt , Rear Brake Overehaul Kit (Minor) , Speedo Cable 3000Mm Long Procal , Minor Rep Kit For Clutch M/Cyl Consisting Of-Seal Sealseal , Assy Air Cylinder , Wheel Brakecyl 38.1Mm Dia , Low Pr Switch , Onloader Valve Assy , Seal Kit (Steering Gear Box) Zf , Assy Clutch Master Cylinder , Repair Kit , Brake Disc , Kit Wheel Cylinder , Repair Kit (Major)M/C , Major Repair Kit For Master Cylinder , Kit Caliper W/O Piston , Assy Inner Handle Lh , Assy Hp Line (Rail To Injector No 2) , Assy Hp Line (Rail To Injector No 4) , Minor Repair Kit For M/Cyl Consisting Of , Bushing , Cylinder Block , Gasket Pushrod Cover , Crankshaft Normal With Pin , Joint Piece , Filter Insert (Stage -I) , Assy Pull Cable (Accel) , Pressure Protection Valve , Bearing Cyl Roller (For Tail Pinion) , Crown Wheel & Pinion 41/7 Ratio , Ignition Cum Steering Lock , Turbocharger , Fan(Viscous) 10 Blades , Pump Water , Fan Engine With Viscous , Sealing Washer A16x20din 7603 Cu , Assy Auxiliary Water Tank , Shift Fork 4/5 Speed , Guard Plate 3.40 Mm Thk , 4Th Gear On Counter Shaft , Reverse Idler Gear Shaft , Cold Start Pilot Kit , Assy Master Cylinder 25.4 Dia , Kit Decarb Gasket Tc , Service Indicator , Assy 310 Dia Clutch Disc , Leaf 10Th , Throwaway Filter , Fuel Gauge (Pricol) , Brush Assy , Axual Roller Brg , Tapper Roller Bearing Front Hub , Housing (Front Axle Joint Cross Left) , Spg Brake Chamber Repair Kit(Msp5/1) , Repair Kit (Msp/2/2&6/7) , Repair Kit (Msp 3/65) , Repair Kit Trailer Control Valve , Door Glass Lh , Door Glass Rh , Assy Window Regulator Lh , Assy Window Regulator Rh , Temperature Gauge M/S Minda , Air Dryer With Unloader Valve , Rep Kit Air Dryer Assy , Wiper Blade , Reverse Light Switch , Wiper Blade Front (Driver Co Driver ) , Lining Kit (Std) , 352 Dia Clutch Disc Assy (1.75Spline) , Cover Assy(1.75 Inch Spline Dia) , Element Fuel Water Seprator , Air Filter Element Primary , Gasket Kit Cyl Head(Air Compressor) , Repair Kit Piston Assy ( Air Compressor , Alternator 24 Volts 75 Amps , Alternator (12V 55 Amp ) , Shim 0.4 Mm Thick , Roller Cage Single Row , Handle Inner Rh , Gasket Kit Oil Sump , (Deleted) Alternator 12V 135 Amp , 17W Hi Power Wiper Motor , 2Nd Leaf , 3 R D Leaf Front Spring , 3.2 Dia Speedo Cable 3600L , 3Rd Leaf , Adjusting Eccentric With Hex Nut , Adjusting Fork , Air Pressure Gauge , Alternator 24 Volts 45 Amp , Assy6 Btaa 155H.P.Engine Completewit , Assy 240 Dia Cl Disc Luk Ind (F 810 Ds) , Assy 6Bt 5-9 125 Hp Engine Complete With , Assy Arm Wiper , Assy Battery Cable Negative , Assy Battery Cable Positive , Assy Blade Wipper , Assy Blinker Lamp R.H , Assy Blinker Lamp With Bulb Lh , Assy Canopy , Assy Clutch Disak 330 Dia (Double Ring) , Assy Clutch Pressure Plate 330 Dia , Assy Combination Switch , Assy Cyl Head With Valve(Mico Injector) , Assy Cylinder Head Complete , Assy Door Lock Lh , Assy Drive Shaft Left Complete , Assy Drive Shaft Right Complete , Assy G-600-6/6.58 Gear Bos Complete Rhd , Assy Fan (Emdet) , Assy Front Shock Absorber Gabriel , Assy Fuel Injection Pump (Lucas) Euro Ii , Assy Fuel Line (Fuel Feed Pump To Fuel F , Assy Fuel Water Seperator With Valve , Engine 697Na (Lowered) Engine Complete W , Assy Handle Outer (Door Lh) , Assy Head Lamp Lh (Lumax) , Assy Head Lamp With Bulb Rh (Motorised) , Assy Head Lamp With Halogen Bulb Lh , Assy Head Lamp With Halogen Bulb Rh , Assy Housing With Diaphragm Spg , Assy Joint Cross Right , Assy Lamp Warning Indicator-4 Bank 24V , Assy Lamp With Switch , Assy Link Rod , Assy Link Rod , Assy Motorised Head Lamp Complete 24V Lh , Assy Oil Filter(Spin On Type 4X4) , Assy Oil Separator , Assy Outer Handle Lh , Assy Outer Handle Rh , Assy Pick Head Bkt , Assy Pipe , Assy Radiator Block W/Filler Cap W/Vaccu , Assy Release Bearing (1.75 Dia) , Assy Release Cable Comp. (Centre Flap) , Assy Safety Belt Lh , Assy Service Indicator , Assy Side Ind.Lamp 24V-Lh , Assy Tail Lamp Lh , Assy Tail Lamp Rh , Assy Wiper Arm (Driver ) , Assy Wipper Arm And Blade Co-Driver , Battery Cut Off Switch , Bearing Needle , Beeper Alarm Unit , Blinker Glass Lh , Blinker Lh , Blinker Rh , Blinker Transmitter , Boot , Bracket (Shovel End) , Brake Actuator(Voss)24/75 , Brake Chamber Type 24 , Brake Shoe With Lining Std , Breakactuator (Voss Lh) 24/75 , Brg Drive End , Brush Box Assy , Brush Carrier Assy , Brush Carrier Assy , Brush Gear Assembly , Brush Set(4) , Bulb 12/3 21/5 W , Bulb F15 Wts 29201 , Bulb G12 V 10W Din 72601 , Bulb Rl 12V 21Din 72601 , Bush , Bush (For King Pin) , Butting Ring 3.10Mm Thik , Butting Ring 3.15Mm Thk , Butting Ring 3.20Mm Thick , Butting Ring 3.25Mm Thk , Butting Ring 3.5Mm Thick , Butting Ring 3.9Mm Thick , Butting Ring 7.00Mm Thick , Butting Ring 7.10Mm Thick , Butting Ring 7.20Mm Thick , Butting Ring 7.4 Mm Thick , Canopy (Top) , Centre Bolt M12x200 Is9484 , Centre Pin Filter Cover To Filter Hsg , Change Over Switch , Clamp , Clutch Release Bearing , Clutch Release Bearing (Self Centering ) , Combi Switch(Ms Harness) , Connecting Rod Brg Set Std-1 , Constant Mesh Gear Counter Shaft(Ratio 1 , Cover Electronic Blinker Glass Rh , Crank Shaft Normal , Crown Wheel & Pinion (41.7) , Cup , Diaphragm , Diaphragm , Diode Aux , Door Handle Outer Rh , Door Lock Lh , Door Lock Rh , Drain Hose , Drive Assy , Drive Engine Electrical Starter , Drive Shaft With Raito 1:8:98 , Dual Brake Valve , Dual Brake Valve(Voss) , Elbow Km 22X1 Sts-16558 , Elect Temp Gauge T , Eng Overhaul Seal Subkit , Assy Engine Complete W/O Starter Motor B , Engine Assy 6 Btaa 5.9 130Hp Bs Iii Engi , Engine Assy With Peripherals For Tata Su , Engine Comple With 3 Rvlineralternat , Engine Screw Driver 08 X 5.5X125 , Exhaust Flap , Fan Assy , Field Terminal , Filler Profile ( Wild Shield Glass ) , Fixing Bracket Assy , Flasher Kit , Flasher(24V) , Flasher(24V) , Follower , Front Spg Assy , Front Spring Leaf 2Nd , Fuel Flexible Pipe , Fuel Gauge , Fuel Water Seprator , Fuse Link 8 , Gasket , Gasket , Gasket , Gasket (Cover) , Gasket Between Cover & Hub , Gear Spur , Glass Regulator , Governor Plunger , Graduated Hand Brake Valve , Halogen Lamp 12V 60/55W , Halogen Lamp 24V 75/70 W , Head Lamp Bulb A 12V 45/40Wdin 72601 , Hex Head Bolt , Hexagonal Key 12 Is 3082 , Horn 12 V , Horn 24 V , Hose Assembly Nonmetalic , Housing (Front Axle Joint Cross Right , Hp Engine Complete With 3Rvliner Alter , Injection Nozzle , Joint Bushing(Top) , Joint Rubber(Bottom) , Key Woodruff Key , King Pin Upper , Kit Lining Set Std Non Asbestos , Kit Starter Motor Cinsisting Of , Knob Gear Shift Lever , L/D Screw Driver 0.4X2.5X50 , Lamp 12V 2W(Black Out Lamp Rear)Ts 29201 , Lamp 24 V-10W 24/1 , Lamp 24V 2 W , Lamp 24V 21Wd 24/1 T529201 , Lamp 24V-4W , Lamp Unit Vehicular , Leaf 6Th , Leaf 6Th (Front Spring) , Leaf 6Th (Lh) , Leaf 7Th , Leaf 8Th , Leaf 8Th , Leaf 9Th , Leaf 9Th(Lh) , Lining Std 12.2Mm Thick , Locator Negative , Lock Washer , Locking Plate , Low Oil Pressure Switch , Main Bearing Set Std 1 , Main Brg Set Std , Main Line Switch , Major Repair Kit Air Compressor , Map Reading Lamp , Master Cylinder Repair Kit , Minor Rep Kit (Tmc) , Nozzle Holder Without Injection Nozzle , Offr Drg 10 Vacuum Booster , Oil Bath Air Filter , Oil Filter , Oil Pressure Switch , Oil Seal , Oil Seal , Oil Seal(Fuel Load Stop) , Plate (Radiator Mtg)Rh , Plate Clutch ( Discclutch ) , Plunger , Power Steering Gear Assy , Pulley , Pump Fuel Injection (Rotary) , Pump Fuel Injection(Rotary) , Quick Release Valvevos W/Adaptor , Radiator Cap , Rear Sprg Assy (Lever) , Rectifier Assy , Reducer Oil Separator , Regulator , Relay , Relay 24V , Relay For Auxilliaries 12V E D , Relay Solehoid Engine Starter Electrical , Relay Starter Solenoid , Relay Valve 1 Del Port Plug , Relay Valve Frt Br Circuit , Relay With Resistor , Repair Kit Air Cylinder , Repair Kit Brake Chamber Type 24 , Repair Kit Drying And Distributtion Unit , Repair Kit Dual Brake Valve , Repair Kit Foot Control Valve , Repair Kit For Stack Adjuster , Repair Kit For Valve Pump , Repair Kit Frt Spring Brake Actuator , Repair Kit Spring Brake Actuator Type 24 , Rotor Assy , Rubber Bellow , Rubber Bellow(Dust Boot) , Rubber Bush , Rubber Hose (Air Filter End) , Rubber Hose (Engine To Radiator) , Rubber Hose Air Filter Outlet , Rubber Hose Engine To Radiator , Rubber Mould W/S Glass , Rubber Pad , Rubber Support Rear Lh , Rubber Support Rear Rh , Screen Filter Assy , Sealing Kit Zf Vane Pump , Shaft Sealing Ring , Shim 0.14Mm Thick , Shim 1.16 Mm Thk , Snap Ring 2.78Mm Thk , Snap Ring 2.88Mm Thick , Spacer Washer 3.35 Mm Thk , Spanner Double End 8X10 , Speedo Cable 3200 Mm Long , Spring Bush , Spring Pin ( To Fix Rear Spring Shackle , Starter Motor 12 Volts , Starter Motor 12V (Make Tvs Lucas Steel , Starter Motor 24 Volts , Starter Motor 24 Volts , Starter Relay 24V 50A , Starter Solenoid Switch , Stator Assy , Stator Assy , Stearing Mtdcombi Switch , Tail Light Vehicular , Tail Light Vehicular , Tapered Roller Brg(Outer) (75X130x41) , Tempe Transducer , Thrust Washer , Thrust Washer 2.30 Mm Thick , Tool Bag , Trailer Control Valve Voss , Un Loader Plunger , Valve , Valve , Valve Seat Ring Exhaust(Cng)Normal , Wheel Cyl With Citradelip 44.45 Mm Dia , Wheel Cylinder 44.45 Mm Dia (Bi) , Wheel Spanner 27X30 A/F , Wind Shield Glass Lh , Wiper Motor , Wiper Motor 17W , Woodruff Key , Assy Blinker Lamp (Lh) , Assy Handle(Winding Regulator) , Assy Blower , Master Cylinder Repair Kit(Api) Consisti , Assy Cab Lamp (With Buib-24 V) , Spring Brake Actuator W/Adoptor Type (12 , Assy Cab Complete(With Roof Hatch) , Assylamp Warning Indicator 4 Bank 24V , Rivet , Pressure Transducer , Crown Wheel And Tail Pinn (41/71Orlikon) , Stearingmtd Combi Switch , Assy Drive Shaft Right Complete , Assy Drive Shaft Left Complete , Rear Shock Absorber , Repairkit Consists Of 17 Items , Drying & Distri Unit Hi Pr Voss , Assy Side Ind.Lamp 24V-Rh , Electric Buzzer , Wiper Timer 24V , Elect.Temp Gauge 24 V (Backlit) , Blinker Lamp Rh 24V , Blinker Lamp Lh 24V , Wind Shield Glass(5.76 Thk) E Certified , Assy Clutch Disc Pressure Plate , Starter Motor 12 Volts , Rubber Hose , Head Fuel Filter , Rpm Meter 24V (Backlit 1200-2000) , Cartridge Fuze Link 10 Amp , Drive Assy , Armature Assy , Field Coil Assy , Oil Ring , Assy Steering Spindle , Temp Transducer , Assy 6Bt 5 9 125Hp Engine Complete With , Assy Gbs-40 Gear Box 8.02 1St Gear Ratio , (Deleted) Engine 697 Ina (Lowered) , Assy Rer Axle Comp Wt Dfrntl Lockr A 104 , Assy Rear Axle Compwith Differental Lo , Ball Socket Hd Comp , Cooling Water Tele Thermometer W/O Plug , Main Light Switch , Glow Plug Switch , Saloon/Out Side Mirror , Radial Seal Ring , Centre Bolt , Centre Bolt , Door Lock (Rh) W/O Locking Device , Door Lock (Lh) With Locking Device , Cover Clutch Housing Upper , Fuel Tank Cap , Castle Nut , Fuel Injection Pump W/Ksb Exptc (Mico) , Pump Fuel Injection(Rotary) , Pumpfuel Injector ( Rotary ) , Pump Fuel Injection(Rotary)Ve 6 , Bolt 083 Ts 17140 , Stud Am10x60 Is 1862 , Hex Nut M8x Is1363 , Wood Ruff Key4x6.5-Is 2294 , Worm Drive Hose Clip 100A Is 4762 , Felt Disc , Return Spring(Clutchrelease For Long T , Air Take Elbow , Clutch Master Cylinder With Bottle , Water Temprature Guage , Assy Tube (15X925) , Speedometer ( 0.84 ) , Alternator With Built In Regulator , Main Line Switch , Cylinderical Roller Brg , Assy Pto W/O Shift Lever , Gasket , Rubber Cap For Rev Ind Switch , Gear Boxhousing , Assy Gear First Speed , Cylinder Head Gasket , Assy Fly Wheel , Fuel Flexible Pipe From Feed Pump To Fue , Rubber Sleeve , Mounting Rubber Lh & Rh (For Front Suspe , Valve Seat Ring Inlet(Normal) , Assy Crank Shaft , Main Brg Set For Shaft Dia 87.75 Mm R/Si , Assy Piston Set ( For Cyl Bore 97.00 Mm , Cam Shaft With Cylinder Pin , Cam Shaft With Cyl Pin , Assy Fuel Filter With Strainer , Rubber Cuff/Hose (For Precleaner) , Piston Pin Circlip With Rings Std , Bracket For Alternator , Seal Kit , Repair Kit Hyd Brake Wheel Cyl Front , Assy Injector Euro Iii/Bs Iii , Claw(For D1 Cr Injector) , Assy Fip (Dicor) Rotary Type , Turbo Charger , Cogged V Belt 1135M Lg , Cylinder Head W/Valves , Valve Guide(Normal) , Roller Chain(Oil Pump) , Alternator With Double Groove Pulley 65 , Kit For Release Lever , Joint Rubber Upper , Joint Rubber(Lower & Upper) , Sealing Ring , Tenth Leaf , Joint Rubber , Friction Pad , Brake Shoe With Lining Std , Stop Washer , Repair Kit Dual Bake Valve , Zf Tank Assy , Steering Assy Complete , Major Seal Kit Steering Gear Box , Assy Power Steering Gear Box , Ammeter (Flat Rim) , Speedometer ( Li ) , Assy Head Lamp With Halogen Bulb Rh , Assy Hd Lamp Lh Withhalogen Bulb 24V , Tommy Bar , Heat Sink Assy(-Ve) , Starter Assy , Slip Ring End Shield , Negative Terminal , Lead Assy , Wood Ruff Key , Insul Washer , Heat Sink Assy , Brush Box Assy , Pulley , Fan Assy , Protective Cap Rubber , Assy Frt Axle Hsg W/Supporting Tube , U Clamp , U Clamp Rh , Assy Drive Shaft Right Complete , Assy Drive Shaft Left Complete) , Rear Axle Shaft , Gaiter , Assy Steering (Zf) , Exhaust Pipe Front Part , Battery Cable (Positive) , Battery Cable (Negative) , Air Pressure Gauge , Switch Key , Assy Hazard Warning Switch ( Push Pull , Assy Clip Locking (Shovel) , Clip Valve End , First Leaf With Bush , Front Spring Assy Rh , Bush , U Clamp , Centre Pin , U-Clamp , Gaiter , Spherical Washer , Bearing Slip Ring End , Assy Hub Rear , Rear Axle Shaft , Rubber Sleeve , Pr Transducer (Oil Pr-Switch) , Assy Indicator Lamp (Hand Brake) , Assy Blinker Lamp (Rh) , Low Air Pressure Switch , Puller For Front Wheel Hub , Wiper Arm , Wiper Motor 17W -Hi Power , Assy Spring Cab Mounting Rear , Rubber Buffer Upper , Brake Lining Front 13.3Mm Thick Std , Brake Lining Front , Assy Boot Rear , Accelerator Lever Assy , Relay With Resister 24V , Brake Lining Rr.Rs , Acessories Kit Wiper , Assy Housing W/Intermediate Flange , Flasher 24V , Assy Blinker Lamp L.H , Hazard Warm Switch , Assy Indicator Lamp (Low Air Pressure) , Graduated Hand Control Valve , Oil Pressure Gauge , Water Temp Gauge , Fuel Gauge 24V , Assy Blinker Lamp Lh With Bulb , Heat Sink Assy (Aux ) , Spacer Ring (Swivel Head) , Megnetic Valve , Magnetic Valve (24 V) , Rotor Final Assy , Push Pull Switch , Kit For Electrical Wind Shield Washer , Door Handle With Key Rh , Assembly Door Lock Rh , Assy Crown Wheel And Pinion(37/7) , Synchroring (1/2/3 Carbon Lining) , Fuel Gauge , Temperature Gauge With A/C Cut Off , Assy Tail Lamp , Knock Sensor 25348220 Delphi , Stator , Ecu ( Transfer Case ) , Assy 240 Dia Cl Cover Luk India , 352 Dia Clutch Dis Assy , Releasing Bearing Costing Service Kit , Assy Front Shock Absorber , Assy Rubber Bellow , Set Of Main Bearing(Std) , Assy Con. Rod , Clamp Hose , Air Compressor , Minor Repair Kit Air Compressor , Repair Kit Piston Ring , Turbo Charger , Starter Motor 12 V , Fan , Viscous Fan 22 Inch , Valve Delivery , Rod Seal-1 , Rod Seal-2 , Rod Seal-3 , Rod Seal-4 , O Ring , Sealing Washer , Wiper , Quard Ring , Sealing Washer , Sealing Washer , Gasket , Plunger Seat , Square Ring , Oil Seal , O Ring , O Ring , Sealing Washer , Sealing Washer , Ssk For Manual Valve Rotary , Gasket Pto , Gasket Pump , Shifling Shoe , Rlf Catridger , Oil Strainer , Gasket , O Ring , Copper Washer , Bonded Seal , Hose Clamp , Bonded Seal , Gasket Cyl Hd , Gasket Oil Filter Housing , Impeller , Wire For Locking (Releasing To Sleeve) , Bushing (To Rear Spring Shackle) , Rear Spring Pin , Stud Bolt , Pressure Spring , Pressure Spring , Assy Cyl Head With Valves , Cyl Head , Crown Wheel Assy , Protective Cap Rubber , Rubber Fastner , Wiper Blade , Valve Seat Ring Exh Std , Inj Timer Device Assy , Shifting Fork , Starter Motor 12V , Hose Clip Screw Type , Parking Bulb Hl 12V4w Din 72601 , Main Bearing Set Std , Delivery Hose Cavas 38 Mmx20mm With Gm C , Multy Cylinder Pump , Pump Element , Delivery Valve Assy , Governor Assy , Assy Engine Mounting Front , Passenger/Driver Fan 24V , Piston Pin , Leaf 7Th , Assy Main Line Switch , Wiring Harness Main , Assy Cable Set , Assy Main Cable Set (Front To Tail ) , Rubber Hose , Instrument Cluster(1:0. 80)M/S Minda , Ins Cluster Ms Ii L , Shim 1.24 Mm Thk , Rubber Sealing Ring , Assy Strainer Oil Pump , Assy Fan (Borg Warner) , Rep Kit L.S.E.Coil , Repair Kit Solonoid Switch Minor , Locking Ring , Diode Plate Assyve , Field Coil , Regulator Assy 12V , Armature , Rotor Assy 12V , Assy Wiper Blade(Driver) , Horn(Low Tone)24V , Assy Blinker Lamp With Bulb Rh , Assy Combi Switch (Pec) , Wiring Harness Stop Lt Swand Lp Sw , Repair Kit Graduated Hand Brake Valve , Temperature Tranducer , Assy Ball Joint Top Wish Bone , Oil Seal Hub Outer(110X129x9) , Assy Bracket Rh On Eng Mtg Rear , 352 Dia Clutch Cover Assy , Water In Fuel Ind 12V/24V , Repair Kit Relay Valve , Turbo Charger , Bearing Bushing , Lamp H4 24V 75/70W (For Motorised Head L , Assy Aux Gear Box Completewith 8 Bolt , Assy 6Bt (125 Hp) Engine Complete With 3 , Assy Gbs-40 Gear Box , Assy Gear Box Gbs-50 , Assy Engine 4Sp Dicor Bs Iii(Assy Engine , Assy Rear Axle Complete , Assy Aux Gear Box Complete , Assy Front Axle Withouthub-4.56 (Std) , Assy G-76-5/3.86 Gear Box Complete , Assy Front Axle(Live) Complete With Brak , Engine Complete With 3Rv Liner Alternato , Engine Assy 6 Bt-5.9-145 Hp Engine Compl , Engine (697 Turbo Charger) , Assy Gear Box G 600 6/8. 47 Complete , Break Bleeding Tube , Brake Bleeding Hose , Regulator , Tail Light(Lh) 4 Chamber Rectangular , Assy Filter Element (Lumax) , Rectifire Assy , Speedo Cable 3.2Mm Dia 3000Mm Long (I.I. , Rear Wind Shield Rh , Assy Water Pump , Nozzle , Key Ring , Switch Key Ring , Laminated Passenger Door Glass , Assy Water Tank 55 Ltrs , Lock Nut , Release Bearing Assy , Cylinder Head Gasket( 1.7Mm Thick) , Priming Pump Hand , Repair Kit (Msp 3/62) Hand Control Valve , Clutch Sleeve With Brg , Filter Element , Regulator Handle , Front Spring Leaf 8Th , Assy First Leaf With Bush , Third Leaf , Sealing Ring , Wheel Cylinder Repair Kit (Bi) , Friction Washer , Universal Joint , Gear Ring , Clutch Release Sleeve With Bearing , Rear Axle Shaft Gear , Yoke Universal Joint , Transfer Label , Fuel Filter , Terminal Negative , Distributor Head , Joint Bushing , Speaker (Ahuja Make ) , Music System Cassette Player(Ahuja Make) , Flag Red Post Dia 20Mm Welded On Both Si , Pole Screw , Oil Seal , Cover Electronic Blinker Glass Lh , Gasket , Blinker Lamp Lh , Bulb 21 W Ts-29201 , Horn Electrical , Injector , Seal Kit(Valve Sleeve) , Transmission Mechanical Vehicular/Assy G , C.E. Bracket Assy , Axle Assy Automotive Driving , Sealing Gasket 0.50Mm Thk , Clutch Release Bearing , Alternator Assy With Double Gnved Pully , Oil Seal , Lamp 24 V 2W , Solenoid , Spacer Ring Swivel Head , Sump Packing , Spanner Deac 08X10 , Radiator Engine Coolant , Shaft Straight , Shaft Straight , Screw Banjo Connector , Ball Pivot , Steering Lever Left , Steering Lever Right , Stud Bolt (For Mtg Cyl Hd) , Hex Nut , V Belt (Cogged 980 Ig) , Bushing , Prefilter Sleve (Mfr Part No. 1450-410-0 , Assembly Door Lock Rh , Solenoid Switch , Field Coil Assy , Starter Motor(Rf 78M45) , C E Bush , Hose Plain , Air Compressor (Top Port) , Flasher(24 V) , Assy Comb Switch , Cover Filter , Assy Head Lamp With Bulb 24 V Offer , Rubber Hose (T Connector To Radiator) , Field Coil Assy , Bearing Bush Ce , Pole Screw , Thrust Collar , Terminal , Assy Canvas Cover , Air Filter Element Primary , Solenoid Switch , Brush Set (Insul Brush) , Solenoid Switch , Brush Gear Assy , Stainless Steel Bolt M6x20 Long With Nyl , Push Tap , Gasket , Stainless Steel Brush 5Cm Widthx20cm Wit , Bearing Bush Inter Bkt , Filter Fuel , Suction Hose Cavas 38Mmx30m With Gm Coup , Driven Disc&Cover Assy , Gasket Rear Axle Housing Cover , Fuse 8Din 72581 , Repair Kit Hyd Brake Wheel Cylinder , Cartridge Lub Oil Filter , Brake Drum Rear , Armature Assy , Drive Assy , Relay With 6 Pin , Fan , Rep Kit(For Wheel Cyl) , Brake Shoe Rear With Brake Lining , Locking Washer , Nut Wheel M20x2.5 , Piston Cup , Bushing Sleeve , Assy Rectangular Head Lamp Rh , Bulb D 12/3-21/6 Ts 29 201 , Assy Tail Light Four Chamber Lh , Assy Rear View Mirror (Outside) Rh (Luma , Assy Rear View Mirror (Outside) Lh (Luma , Wiper Motor , Stop Light Switch (Pec) , Regulator And Brush Box Assy , Brg Bush , Ignition Key , Tool Bag , Inspection Lamp With 10 Mtr Long Cable E , Speedometer , Solenoid Operated Valve , Sealing Kit , Cab Lifting Bar , Assy Pipe (To Air Gauge 2) , Grab Handle Lh , Assy Pipe , Grease Gun , Timing Device Piston , C E Bearing , Pushing Electromagnet , Solenoid , First Aid Kit , Electronic Flasher Kit , Electric Buzzer , Triangle Kit Bag/Small , Banjo Bolt A8n 15011 , Pressure Line Cyl No. 5 , Pressure Line 4Th Cyl , Spring Assy Leaf , Pressure Line 2Nd Cyl , Pressure Plate Assy , Oil Seal , Slave Cyl Clutch , Governor Shaft , Needle , Cylindrical Roller Brg , Repair Kit Water Pump Major , Insp Lamp With 10M Cable Comp W/Single , Three Way Fuel Lock , Gasket Cyl Head , Main Leaf With Bush , Cylinder Roller Bearing , Filter Fuel , Filter Fuel , Assy Tail Lamp Lh , Assy Tail Lamp Rh , Assy Spare Wheel Lifting Unit , Thermostate , Solenoid Switch , Fluid Container (Clutch) , Assy. Nozzle , Seal Sealing Ring , Assy 6Bt Aa-5.9-155 Hp Engine Complete , Sppaner Deac 13X17 , Wiper Motor24v
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 1
Multi State View Result →
29.
Drinking Water Supply and Sanitation #10163068 Price Bid
Supply, Delivery, Installation And Trial Operation Of Electro-Mechanical Components And Allied Works At Ground Water Based Tubewell No-I , Ii And Arsenic Iron Removal Plant At Mabarakpur Piped Water Supply Scheme In The District Of Malda-3 Submersible Pump Directly Coupled With Water Proof Suitable Size Motor Having Following Specification:Pumpshaft- Stainless Steelimpeller- S.S / Gmoutlet Size-65 Mmmotorsubmersible Type 3 Phase, 50 Hz, 415V ± 10% , 2900 Rpmmotor Mustbe Suitable For Operation With Star-Delta Starter This Item Will Be Procured Based On Yield Test Report Of T / W And Best Efiiciency Point As Per Direction Of Eic. Test Certificate Along With Characteristic Curve Shoule Besubmitted At The Time Of Delivery. 4 For T / W No. I & Iidischarge Of Clear Water = ( Q ) = 33 M3 / Hr.Total Head ( H ) = 35 M. 5 1.1 Kv Grade 2.5 Sqmm 3 Core Water Proofflat Submersible Cable For Above Motor. 6 1.1 Kv Grade 16 Sqmm 4 Core Xlpe Insulated Al. Ar. Cable Cable Conforming To Is-7098 ( Part-1 ) 1988 With Upto Date Amendment. 7 Supply, Delivery And Storage At Site Of Wall Mounted 2 Mm. Thick Epoxy Painted Sheet Steel Enclosed Front Open Fully Panel For Fully Automatic Cum Manual Control Centre For Operation Of The Pump Motor In Dol Mode, Actuator With Dol Starter, Chlorinator With Dol Starter And Timer Operated Outdoor And Indoor Lighting And Also Spares Feeder As Per Approved Drawingand Nit Specification. 8 For T / W No. I & Iirange Of Pmcc Panel:5 Hp To 7.5 Hp Dol 9 Supply And Delivery Of The Following Valves, Pipes, Gauges Etc. At Site Of T / W No. I & Ii. 10 80 Mm Dia M.S. Seamless Column Pipe ( Black ) 6.8 Mm To 7.1 Mm Thick With 150 Mm Long Heavy Type Socket At One End. 11 3.00 Mtr. Long Excluding Socket Having 8 T.P.I. Thread. 12 1.5 Mtr. Long Excluding Socket One End Having A Thread Of 11 T.P.I. & The Other End Having A Thread Of 8 T.P.I. 13 Heavy Type Suitabledia Ms Suspension Clamp Along With Nuts Bolts And Washer. 14 Cast Iron Wafer Type Three Phase Actuator ( Rotork Range, Three Phase 415 V, Multiturn Electrically Actuated ) Operated Butterfly Valve Of Dia 80Mm ( P.N-1.0 ) As Per ( Is-13095 Ip-68 ) Test Certificates From Both The Manufacturer Are To Be Submitted At The Time Of Delivery 15 80Mm Dia Cidf Sluice Valve-1 No., Non Return Valve-1 No., Cidf 90° Bend-1No., Ci Flanged Tee-1No. Blank Flange-1No., Ci / Ms Flanged Short Piece 0.50 Mtr.-2 Nos, Ci / Ms Flanged Pipe 1 Mtr.- 2 Nos. Etc As Per Is Specification And Certification For Construction Of Delivery Pipe Line And Wash Out Line. 16 Heavy Type 250 Mm Dia Split Type Tube Well Cover With 12 Mm Thick Clamping Arrangement Including Holes Of Column Pipe, Air Pipe And Cable Entry With 2 Sets Heavy Type Suspension Clump, Nuts, Bolts And Washer As Per Departmental Design. 17 Depth Gauge 100Mm Dia With Steel Air Pipe Of Required Length With All Accessories For The Above Work Including Supply Of Good Quality Hand Pump. ( This Cost Includes 15 Mm. Dia G.I. Pipes And Specials ) 18 Pressure Gauge ( H.Guru / Febig ) 150Mm Dia ( 0-7Kg / Sq.Cm ) Brass Cock And Fitting Complete. ( This Cost Includes 15 Mm. Dia G.I. Pipes And Specials ) 19 50 Mm. Dia. Non Metalic Pipes ( Is:14930 ) And Specials For Protection Of Submersible Cable ( As Per Site Requirement ) 20 Anti Snapping Safety Device For Pump Set By Supplying Suitable Size Ms Clamps Two Sets And Nylon Rope Of Required Length Including Supplying Of Nuts, Bolts And All Other Materials. 21 100 Amps Porcelin Based Rewireable Type Male Female Kit Kat Fuse Unit 22 100 Amp 415 V Rewireable Type Tpn Main Switch. 23 Laying Of 16 Sq. Mm. 4 Core Al. Ar. Cable In Wall / Floor By Supplying Of All Necessary Materials As Per Ie Rules And As Per Direction 24 Installation Of The Materials ( To Be Supplied Under Above Sl No 1 To 3.01 & 5 To 6.13 ) Such As Pump Motor Set With Column Pipes, Valves, Panel, Fiting Fixing Pressure Gauge, Depth Gauge, Non-Return Valve & Drawing Delivery Out-Let & Washout Line With The Supplied Specials / Accessories By Providing Antisnapping Cage Of Suitable Size Including Supply Of Cable Gland, Sockets, Wooden Board, Control Cable Etc Including Brick, Sand, Cement Rod Etc As Required To Complete The Job As Per Direction And Up To The Entire Satisfaction Of The Eic. 25 Making Brick Pillar 0.25 Mtr X 0.25 Mtr. For Supporting Of Valves And Pipes With 12 Mm Thick Plaster And Net Cement Finish Complete. 26 Supply, Delivery Of M.S Kiosk Box Of 661Mm X 559 Mm ( Lxw ) Size Having Thickness Of 1.5 Mm With Angle Support At Four Legs Having Hight Of 661 Mm With Provision Of Locking Arrangement, Supply Of Lock, Cable Entry Point Incl Painting By One Coat Of Black Paint Over One Coat Of Primer All Complete. 27 Making Suitable Size Pump Foundation Including Erection Of Kiosk Box With Supplying Of Necessary Cement, Sand And Stone Chips Including Plastering And Net Cement Finish Complete. 28 Making Double Earthing Arrangement In Compliance With Ie Rules By G.I. Pipe Electrode Of 50 Mm. Dia 3 Mtr. Long 2 Nos For Panel And Pumping Machinery 25 Mm. X 6 Mm. G.I. Earth Strips From Earth Pit To Panel And All Other Accessories Required To Complete The Work. 29 Making Internal Electrification Of Pump House Consisting Of Two Bracket Point, One Tube Light Point, Two Bulk Head Point, One Fan Point And 1 No. 74 Watt Led Fixture With Arm Bracket At Outside And One Three Pin Plug Point Including Supply Of All Necessary Materials To Complete The Work As Per Ie Rules And As Per Direction ( All The Fittings And Lamp Should Be Led Type As Per Choice Of Eic ) 30 Supply And Delivery At Site 3 Phase Oil Cooledtype Servo Motor Operated Copper Wound Line Voltage Corrector Conforming To Is-9815 ( Pt.-1 ) -1994 Suitable For Un-Balanced Input Voltage Phase To Phase 200V.-500V Including First Filling Oil As Per Is-335 Where Applicable As Per Approved Drawingand Nit Specification. 31 For T / W No. Ii15 Kva 32 100 Amp 4 Pole On Load Change Over Switch 33 100 Amp Re Wireable Type Tpn Main Switch 34 100 Amp 4 Way Cu Basbar Chamber Box By 16 Swg Sheet Steel Enclosure Including Porcelain Chair Etc.With Painting As Per Direction Of E.I.C. 35 1.1 Kv Grade 415 V, 16 Sqmm, 4 Core Pvc Insulated Aluminiumarmoured Cable. 36 Making Brick Built Foundation With Supplying Of All Required Materials Suitable For The Above Voltage Stabilizer By ( 4:1 ) Cement Mortar Including Holding Down Foundation Bolts And 12 Mm Thick Plaster With Neat Cement Finish, Sloping All Complete As Per Direction Of Eic. 37 Fitting , Fixing Of Change Over Switch, Busbar Chamber And Main Switch As Mentioned In Item No. 17.02, 17.03 And 17.04 On The Iron Angle Frame Of Suitable Size Fixed At Suitable Position On Wall By Supplying All Necessary Fixing Materials All Complete As Per Direction Of Eic. 38 Installation Of The Above Voltage Stabilizer As In Item No.17.01 On The Foundation Including Making All Connection Complete As Per Direction. 39 Drawing And Connection Of Cable As In Item No. 17.05 On Wall / Surface From Change Over To Panel Via Voltage Stabilizer, Bus Bar And Main Switch Incl. S & Fitting-Fixing Of Required Nos. Of Ms Saddles With Earthing Attachment In 10 Swg Gi ( Hot Dip ) Wire, Making Holes Etc. As Necy. Mending Good Damages And Painting. 40 Making Joints Of The Cable By Supplying Compresion Type Gland Thimple, Socket Etc. As Per Requirement And As Per Direction Of Eic. 41 Double Earthing The Whole Installations Complying With Ir Rules Including Supplying Of All Necessary Earthing Materilas For Voltage Corrector Device To Complete The Job As Per Direction Of Eic. 42 Supply & Delivery Of Automatically Controlled 0-100 Lph Diaphargm Type Chlorinator For Accurate Dosing Of Chlorine Solution Into The Waterby Connecting Metering Pump ( Diaphragm Type ) Having Specification As Per Nit:- ( Including Making Provision For Inlet Line To The Actual Storage Tank Of Dosing Solution Of All Materials. ) [ Test & Warrantycertificatesare To Be Submitted At The Time Of Delivery ] 43 Installation Of Above Supplied Chlorinator Including Supplying Of Suitable Capacity Main Switch ( Havells ) Starter & Drawing Of Power Line By Supplying Pvccopper Wire & Continuous Earthing. This Include The Cost Of All Necessary Foundation ( At Least 200Mm Height ) With Concrete Mixture ( Sand, Cement, Stone ) And Neat Cement Finish By Supplying Of All Required Materials And Testing The Entire Set By Supplying Necessary Chemical For At Least 04 ( Four ) Hourstrial Runas Perentire Satisfaction Of The Eic. 44 Supply And Delivery At Site Of Calcium Hypochlorite Granules Minimum Cl Content 60%-65% In Air Tight Plastic Jar ( 25 Kg Each ) As Per Direction Of E.I.C. ( Make- Phe Approved ) . 45 Supply & Delivery Ofmoulded Chair. 46 Supply & Delivery Of The Moulded Table. 47 Supply, Delivery & Installation Of The Following Fan As Directed By Eic. A ) Ceiling Fan 1200Mm Sweep Or B ) Wall Mounting Fan 400 Mm Sweep Including Fan Clamp As And When Required. 48 Commissioning Of The Installation With Full Satisfaction Of Eic And Trial Run As Per Departmental Operation & Guarding By Engaging Skilled Staff For 3 Months. ( Tw No - Ii ) 49 Part-B:Arsenic Iron Removal Plant 50 Supply, Delivery And Storage At Site Of Horizontal Split Casing Centrifugal Pumping Machineries With Baseplate, Flexible Coupling, Coupling Guard, Foundation Bolt Etc. Having The Following Specification : ( Pumps Suitable For Plc Operated Unmaned Operation Facility And Pumping Water From Cwr To Ohr ) Discharge :- 70 M3 Per Hour Generated Head :- 40 Mwcthis Item Will Be Procured Based On Yield Test Report Of T / W And Best Efiiciency Point As Per Direction Of Eic.H-Q-P Curve Of Pumps In Test Bed Has To Be Submitted During The Delivery. 51 Supply, Delivery And Storage At Site Horizontal Foot Mounted Induction Motor Suitable For The Pump Duty Mentioned Above In Item No. 32.00 With Adequate Margin Conforming To Ie 3 Energy Efficient, 1440 Rpm, Ac, 3 Phase, 50 Hz. + / - 5%, 415 V + / - 10%, Class F Insulation With Temperature Rise Limit To Class B Insulation, Ambient Temperature 50 Degree Centrigade, Ip 55, S1 Duty As Per Technical Specification.Routine Test Certificate Of Induction Motor Has To Be Submitted During Delivery 52 Supply, Delivery And Storage At Site Of Monoblock Vacuumpumping Machinary With The Following Specification And As Pernit. :A ) Vacuum : Upto 600 Mm Of Hgb ) Air Flow Rate :1.8 To 20.5 M3 / Hr 53 Supply, Delivery And Storage At Site Lift Type 150 Mm Footvalve Combined With Stainer As Per Is : 4038 Pn-1.6 And Asper Detail Given In The Nit . :-N.B. : Test Certificate To Be Produced For Each Valve ( At Suction Side Of Pump ) 54 Supply, Delivery And Storage At Site 150 Mm Diadouble Flanged Cast Iron Manually Operated Non-Rising Spindle Sluice Valve Generally Conforming Tois:14846 Pn-1.0.:-N.B. : Test Certificate To Be Produced For Each Valve. ( At Suction Side Of Pump ) 55 Supply, Delivery And Storage At Site Of Ci Doble Flanged Single Door Swing Check100 Mm Dia N.R.Vas Per Is : 5312, Part-I, Pn-1.0. :-N.B. : Test Certificate To Be Produced For Each Valve. ( At Delivery Side Of Pump ) 56 Cast Iron Wafer Type Three Phase Actuator ( Rotork Range, Three Phase 415 V, Multiturn Electrically Actuated ) Operated Butterfly Valve Of Dia 100 Mm ( P.N-1.0 ) As Per ( Is-13095 Ip-68 ) Test Certificates From Both The Manufacturer Are To Be Submitted At The Time Of Delivery ( At Delivery Side Of Pump ) 57 Supply, Delivery And Storage At Site 150 Mm Diadouble Flanged Cast Iron Manually Operated Non-Rising Spindle Sluice Valve Generally Conforming Tois:14846 Pn-1.0.:-N.B. : Test Certificate To Be Produced For Each Valve. ( At Common Delivery Header ) 58 Supply, Delivery And Storage At Site 80 Mm Diacast Iron Kinetic Double Orifice Air Released Valve As Per Relevant Is, Pn-1.0. :-N.B. : Test Certificate To Be Produced For Each Valve. ( At Common Delivery Header ) 59 Supply, Delivery And Storage At Site Ms Dismantling Joint Dn 100 Mm Pn 1.0 ( For Delivery Side Ofpump ) 60 Supply, Delivery And Storage At Site Ms Dismantling Joint Dn 150 Mm Pn 1.0 ( For Common Header Ofpump ) 61 Supply, Delivery And Storage At Site Bourdon Type Pressure & Compound Gauges, 150 Mm Dia Cast Aluminium Dial With , Ss Internal, Dn 15 Gi Impulse Line With Three Way Cock.Pressure Guages ( 0 - 15 Kg / Cm2 ) 62 Supply, Delivery And Storage At Site Of150 Mm Dia , Thickness 5.4 Mm And 100 Mm Dia 5.4 Mm Thick Ms Black Pipe Conforming To Is:1239 Part-1 ( 2004 ) ( For Suction, Delivery & Delivery Header ) Along With Necessarybends, Fittings Viz. Flanges, Bolts, Nuts, Gaskets , 150 Mm X 100 Mm Ecentric Reducer, Concentric Enlarger80x100 Mm Etc. As Reqd. To Make The Installation Complete In All Respect. 63 Supply, Delivery And Storage At Site 20 Mm Dia, G.I Pipes ( Medium Duty ) , Water Storage Pvc Tank , Bends, Sockets, Tees, Fittings, And Other Specials, Gaskets , Solenoide Valve , Gate Valve For Auto & Manual Operation Etc. As Reqd. To Make The Piping Arrangement Of Vacuum Pump Complete In All Respect As Per Nit. ( For Priming Arrangement ) 64 Supply, Delivery And Storage At Site 2 Mm. Thick Crca Sheet Steel Enclosed Cubical Type Indoor Floor Mounted415 Volt Mccpanelhaving Required Feeders With Plc. Incomer ( 250 A ) - 1 No, Outgoing Feeder ( 25-35 Hp, S-D ) - 2 Nos, , Valve Actuator Starter-3 Nos, Cholrinator Starter ( 0.5 Hp, Dol ) - 1 No, Vacuum Pump Starter ( 1 Hp, Dol ) - 1 No, Blower Starter ( 7.5 Hp, Dol ) , Outdoor Lighting Feeder And Control Feeder And Genearl Feeder And Plc Feeder. 65 200 Amps, 415 V Porcelin Based Rewireable Type Male Female Kit Kat Fuse Unit With Extension Strip 66 Supply, Delivery And Storage At Site 1.1 Kv Grade50 Mm2 3½Core Xlpe Insulated Al. Armoured Cable 67 Supply, Delivery And Storage At Site 1.1 Kv Grade 6 Mm23core Xlpe Insulated Copper Cable. ( Frommcc Panel To Motor. ) 68 Supply, Delivery And Storage At Site 1.1 Kv Grade25 Mm2 4 Core Xlpe Insulated Aluminiun Armoured Cable. ( From Arp Pump House To Tube Well Site ) 69 Supply, Delivery And Storage At Site 1.1 Kv Grade6 Mm2 3Core Xlpe Insulated Al. Armoured Cable ( From Mcc Panel To Actuator For Power ) 70 Supply, Delivery And Storage At Site1.1 Kv Grade 1.5 Sq. Mm.12Core Pvc Insulatedcopper Controlcable ( From Mcc Panel To Actuator For Control ) 71 Supply, Delivery And Storage At Site Of Electromagnetic Type Flowmeter With Separate Transmitter With Suitable Length Interconnecting Cable For Measuring Flow Of Clear Water. Flow Sensing Element Shall Have Ip 68 Degree Of Protection. Flow Meter Shall Be Opearted At 220 V And Shall Have Flow Rate And Flow Totalisation ( Dn 150 Mm ) 72 Providing Earthing & Lightning Protection For Pump House And Electrical Installation As Per Iss And Ie Rules. ( Earth Pit 2 Nos+ 2 L / A ) 73 Supply And Fixing Of Gi Perforated Cable Tray At Pump House For Laying Of Incoming & Outgoing Power And Control Cables To And From Mcc Panel, Motor And Other Electrical Accessories Having Proper M.S. Structural Support As Per Direction Of Eic. 74 Supply Delivery At Site And Storage Of Indoor And Oudoor Illumination Arrangement Like Suitable Size Wire, Switch , Switch Board , Tube Light Fitting , Exhaust Fan , Ceilling Fan , Led Outdoor Fixturecomplete As Per Nit Specification. 75 Supply Delivery At Site And Storage Of Safety Equipment Like Suitable Capacity Fire Extinguisher , Sand Bucket , Fire Bracket, Rubber Mats, Shock Treatment Chart And First Aid Box, Chair , Table, 415 Volt Danger Board Complete. 76 Supply, Delivery And Installation Of Automatically Controlled 0-100 Lph Diaphargm Type Chlorinator For Accurate Dosing Of Chlorine Solution Into The Waterby Connecting Metering Pump ( Diaphragm Type ) As Per Nit Specification. 77 Supply Delivery And Installation Storage Of 50 Kva Power Correction Arrangement As Per Nit Specification. 78 Installation Of All Items As Mentioned In Sl.No.32 To 53 Including Construction Of Pump Foundations, Pipe Supports, Valve Supports, Laying Of Cables With Necessary Jointing Materials, Earthing Arrangement Of Motors, Starters, Including Supply Of All Erection Items Viz. Rubber Gaskets, Nuts & Bolts Etc., Including Cost Ofwelding Etc. As Required For Complete Installation Including Making Slope Of Floor And Arrangement Of Removing Gland Leckage Water As Per Hydraulic Standard & Ie Rules In Compliance Upto Entire Satisfaction Of Eic. 79 Painting Of The Installation ( Viz.Pumps, Valves, Pipe Lines Etc.By Two Coats Of Epoxy Paint ( Colour To Be Decided By Eic ) Over A Coat Of Primer As Per Direction Of Eic. 80 Testing & Commissioning Of The Entire Installation I.E.Pumps, Motors, Valves Etc. As In Sl No. 32 To 53 As Per Direction And To The Entire Satisfaction Of E.I.C. 81 Operation And Maintenance Of The Entire Installation In High Lift And Low Lift Pumping Stations On 16 Hrs. Basis Including Guarding For A Period Of 90 Days Are To Be Provided With Supply Of Skilled Personnel Including Watch And Ward Personnel From The Date Of Commissioning. During Maintenance Period Supply Of All Consumable Materials Sundrys And Lubricants Are To Be Supplied. Charges Of Electrical Energy During Maintenance Period Will Be Born By The Department. ( For Tw No.-I And Airp Site ) 82 N.B. Progressive Bills Shall Only Be Done After Third Party Inspection Agency Engaged By Phed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
West Bengal View Result →
31.
Road Transport and Highways #9858444 AOC
Bid Are Invited For Axes Felling 3 Kgs Forged Without Handle , Bucket Plastic 18 Ltr Cap , Borosil Glass Medium Size Set Of 06 Pcs , Chainsaw Ms Dash 382 Comma Petrol Driven With 18 Dash Inch Bar Lenght And Chain Guage 1Pt3 Mm , Cushioned Heavy Plastic Arm Chair Red Oblique Black , Chamcha 14 Inch Stainless Steel With Wooden Handle , Dining Chair With Cusion Wooden Of Good Quality , Dah Iron With Handle 20 Inch Meat Choper , Deep Freezer 402 Ltr , Dechi Stainless Steel 14 Inch With Lid , Dechi Stainless Steel 10 Inch With Lid And Handle Comma Stainless Steel , Dechi Stainless Steel 20 Inch With Lid And Handle , Dechi Stainless Steel 18 Inch With Lid And Handle , Donga Oblique Caseroll Stainless Steel With Lid 12 Inch Dia , Door Mat 27 Inch X 15 Inch Jute , Door Mat 27 Inch X 18 Inch Rubber Hole Mat , Dust Bin Big Size 30 Ltr Capacity Plastic , Elect Weighing Machine 10 Kgs , Circular Suspended Dial Type Spring Balance 100Kg , Exhaust Fan Heavy Duty 18 Inch 1400 Rmp , Hand Held Brush Cutter Petrol Driven , Hot Case Thermoware Four Pot Lunch Box , Inverter 1050 Va Oblique 12 V Output Voltage 230V , Inverter 1650 Va Oblique 24 V Comma Output Voltage 220 , Jug Stainless Steel 1 Ltr Cap , Kadahi 24 Inch Iron With Riveted Handle , Kadahi Iron 12 Inch With Riveted Handle , Kadahi Iron 18 Inch With Riveted Handle Round Type , Kadhai Aluminium 14 Inch With Riveted Handle , Karchi Stainless Steel 12 Inch Heavy Guage Food Grade 1Pt4Mm Thickness , Karchi Stainless Steel 14 Inch Heavy Guage Food Grade 1Pt4Mm Thickness , Karchi Stainless Steel 8 Inch Heavy Guage Food Grade 1Pt4Mm Thickness , Led Hd Tv 55 Inch 4K , Led Hd Tv 32 Inch , Lpg Domestic Stove Double Burner , Lpg Gas Stove Heavy Duty , Lpg Regulator , Mattress Twin Layered Coir Foam Mattress , Mug Plastic 1 Ltr , Pad Lock 75 Mm Comma 5 Levers Brass Comma Finish Electroplated , Parat Stainless Steel 16 Inch With Side Edges Mouled , Pick Axe , Plastic Chair With Arms , Pressure Cooker 05 Ltrs Capacity , Pressure Cooker 08 Ltrs Capacity , Pressure Cooker 20 Ltrs Capacity , Rat Trap Material Iron , Ro 50 Lph Uv System With Pre Filter , Service Tray , Steel Charpoy Bed Size 78 Inch X 36 Inch , Steel Almirah Small 48 Inch X36 Inch X18 Inch , Steel Almirah Big78 Inch X 36 Inch X 19 Inch , Stainless Steel Tumbler Comma 300 Ml Capacity , Stainless Steel Rice Spoon 8 Inch , Tea Container Insulated Kettle With Tap 20 Ltr Cap , Tea Thermos Stainless Steel 05 Ltrs Cap , Tea Thermos Stainless Steel 10 Ltrs Cap , Thermos Steel Body 2 Ltr Cap , Thermos Steel Body 1Pt5 Ltr Cap , Tea Pan With Cool Handle , Tea Strainer With Comfortable Handle , Tiffin Carrier 3 Layer Container Stainless Steel , Torch Heavy Duty Re Dash Chargable , Water Purifier Ro Plus Uv 20Lph Cap , Water Storage Tank 1000 Ltr , Water Storagetank 2000 Ltrs , Water Storage Tank 500 Ltrs , Sofa Set Big Size 3 Plus 1 Plus 1 One Seater
Contract Date: Ref. Documents Contract Value : 32.87 Lakh
Government Departments No of Bidders 9
Arunachal Pradesh View Result →
32.
Health and Family Welfare #9834942 AOC
Tender for Re Tender For Supply, Installation And Qualification Of Weighing Balance @ Homco, Valiya Kalavoor , Calibration , Pressure Guage , Vaccum Guage , Vaccum Indicator , Vaccum Transmitter , Compound Guage , Digital Pressure Indicator , Digital Pressure Switch , Pressure Transmitter , Temperature Guage , Temperature Sensor , Temperature Controller , Temperature Indicator , Differential Pressure Guage , Differential Pressure Switch , Differential Pressure Indicator , Differential Pressure Transmitter , Thermo Hygrometer , Digimatic Caliper , Dial Guage , Digital Timer , Stop Watch , Temperature And Relative Humidity Sensor , Screw Guage , Table Top Weighing Balance Upto 1 Kg , Weighing Balance Up To 200 Kg , Air Velocity Sensor , Hour Meter , Rpm Indicator , Rpm Controller , Slip Guage , Temperature Mapping (7 Days) , Rm Store Under Test (25 No. Of Sensors) , Rm Store Approved (25 No. Of Sensors) , Dispensed Material Store (20 No. Of Sensors) , Packing Material Store (35 No. Of Sensors) , Fg Store Alcoholic Product (45 No. Of Sensors) , Fg Store Non-Alcoholic Product (45 No. Of Sensors) , Return Goods Store(15 No. Of Sensors) , Oos- 1 (Rm) (12 No. Of Sensors) , Oos- 2 (Pm) (12 No. Of Sensors) , Unlloading Bay (20 No. Of Sensors) , Released Goods For Despatch (15 No. Of Sensors) , Under Test Sample(16 No. Of Sensors) , Control Sample Area (25 No. Of Sensors) , Media Storage Room (20 No. Of Sensors) , Sorting For Dilution (40 No. Of Sensors) , Sorting For Mother Tincture(40 No. Of Sensors) , Granules Quarantine (18 No. Of Sensors) , Inspection Cum Quarantine (20 No. Of Sensors) , Quarantine Ppm Day Store (15 No. Of Sensors) , Quarantine Dilution (20 No. Of Sensors) , Quarantine Mother Tincture (20 No. Of Sensors) , Herb Store -1 (30 No. Of Sensors) , Herb Store-2 (30 No. Of Sensors) , Onsite Calibration Cgharges (Master Transportation)
Contract Date: Mar 18, 2026 Contract Value : 36.37 Lakh
Cooperative No of Bidders 5
33.
Defence #9749550 AOC
Tender For Provision Of Deficient Married Accommodation At Air Force Station Phalodi Boq (11 Aug 2025).; 1 NOTE: Schedule ‘A’ Part I to XII under Ser No. 1.00to 12.00 are prepriced by MES. Bidders shall insert their lumpsum amount in the green coloured field under Col-6 only. 2 Lump sum price worked outfor BUILDINGS/ STRUCTURES as listed in Sch A Part I. 3 Lump sum price worked out for EXCAVATION, EARTH WORK AND SITE CLEARANCE as listed in Sch A Part II 4 Lump sum price worked out for INTERNAL ELECTRIFICATION as listed in Sch A Part III 5 Lump sum price worked out for INTERNAL WATER SUPPLY as listed in Sch A Part IV 6 Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch A Part V 7 Lump sum price worked out for AREA DRAINAGE as listed in Sch A Part VI 8 Lump sum price worked out for ROAD/ PATH as listed in Sch A Part VII 9 Lump sum price worked out for FENCING/GATE as listed in Sch A Part VIII 10 Lump sum price worked out for EXTERNAL ELECTRIFICATION/STP as listed in Sch A Part IX 11 Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch A Part X 12 Lump sum price worked out forRAIN WATER HARVESTING as listed in Sch A Part XI 13 Lump sum price worked out for HOT WATER SUPPLY as listed in Sch A Part XII 14 SCHEDULE A PART - XIII MISCELLANEOUS ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signifies this fact only. Bidder shall insert their rates in Green filed under Col-6. 15 SITE CLERANCE & DEVELOPMENT 16 M & L for Surface excavation n.exc30 cm deep and averaging 20cm deep and getting out top layer arqanie soil without disturbing or destroy its texture and remove the same to a location specified and stored properly for relaying after the completion of building work exc 50m but n exc 250m complete all as specified and as directed 17 Relaying the soil excavated in Item no 13 to building site for landscaping and gardening complete all as specified and directed 18 S&F colour coaded plastic dustbins of 120 Litre capacity each in Green/Blue/Red in colour as directed by GE , made of high grade UV resistant polyethylene, suitable for segregation of biodegradable, recyclable, hazardous and sanitary waste bins to be durable , Light weight, weatherproof, easy to clean with tight fitting lids and clear identification lables complete all as specified and directed..Note :-Labelling on dustbin are as follows:a) Green color waste bin :- Bio degradable wasteb) Blue color waste bin :- Reusable/ Recycle waste c)Red color waste bin :- Land Fill waste 19 INTERNAL ELECTRIFICATION 20 S & F for wall mounted LED box type tube light fitting 4 x 20 watts industrial commercial interior batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouputboxtype fitting, 230 volts and intregrated electronic driverconnector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. 21 S & F forLED tube light fitting with aluminium housing 2 feet x 10 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cableof suitable sizefrom ceiling rose to fittingwith warranty option of 5 years from date of installationcomplete all as specified and as directed. 22 S & F forLED tube light fitting with aluminium housing 2 feet x 5 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cableof suitable sizefrom ceiling rose to fittingwith warranty option of 5 years from date of installationcomplete all as specified and as directed. 23 S & F for Decorative wall mounted luminaire made out of Nickle finesh square base with bend pipewith unbreakable globe glass suitable for LED bulb and provosion of LED bulb 10 watts complete all as specified and as directed. 24 S & F for ceiling fan, 230 Volts, 1200 mm sweep with mian air delivary 210 CFM, service value of the fan shall be greater than 6.1 (5 star rated) as per BIS with blades, down rod & other necessary accessories with brushless direct current motor (BLDC)with remote system and electrical connections from ceiling rose to fan teriminal complete all as specified and directed. 25 S & F for energy efficient exhaust fan of 225 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existing wall for fan base compelte all as specifiedand directed.(Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be includedin overall rate quoted). 26 S & F for energy efficient exhaust fan of 300 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existingwall for fan base compelte all as specifiedand directed.(Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be includedin overall rate quoted). 27 Supply, installation, commissioning and testing indoor type LT wall mounting Bldg panel board of suitable sizefactory made TTA panel, weather, dust & vermin proof indoor, double door, front openable, locking arrangements made out of 2.00 mm thick mild steel CRCA sheet including required comparment for fixing of four (12) Nos single phase smartmeter, MCCB and MCB and porviding glass view for reading of meter and providing rubber/ PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/ sleeves with maintained the colour code and copper strip/ wire busbar of suitable size to MCCB input and MCCB/ MCB output of suitable length for connection of cable from main busbar, angle iron 50 mm x 50 mm x 5 mm thick supporting frame including applying two coats of powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfacesfor 3 phase 4 wire system 415/ 440 volts grade including internal wiring connections for all outgoing / incomming cable,earthing teminals , danger plate, suitable PCC platform complete all as specified and directed 28 INCOMING(a) Copper strip busbar of suiable of capacity 200 Amps rating wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos.(b)MCCBIP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 100 Amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links -01 No.(c) Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch – 01 No(d)LED Neon indicator lamp (RYB) with holder,230/250 volts,AC -01 set (set of three) Make :- AE/L&TOUTGOING(a) MCB, Single pole & neutral, 40 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 12 Nos (Officers Accn)(b) MCB, single pole & neutral, 10 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 1 No (Stair case lighting)(c) Slot for fixing the three phase smart prepaid meter - 13 Nos (Cost of Smart meter cost will be paid seperately under respective itemly) 29 Supply, installation, commissioning and testing indoor type LT wall mounting Bldg panel board of suitable sizefactory made TTA panel, weather, dust & vermin proof indoor, double door, front openable, locking arrangements made out of 2.00 mm thick mild steel CRCA sheet including required comparment for fixing of four (07) Nos single phase smartmeter, MCCB and MCB and porviding glass view for reading of meter and providing rubber/ PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/ sleeves with maintained the colour code and copper strip/ wire busbar of suitable size to MCCB input and MCCB/ MCB output of suitable length for connection of cable from main busbar, angle iron 50 mm x 50 mm x 5 mm thick supporting frame including applying two coats of powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfacesfor 3 phase 4 wire system 415/ 440 volts grade including internal wiring connections for all outgoing / incomming cable,earthing teminals , danger plate, suitable PCC platform complete all as directed 30 INCOMING(a) Copper strip busbar of suiable of capacity 120 Amps rating wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos.(b)MCCBIP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 63 Amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links -01 No.(c) Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch – 01 No(d)LED Neon indicator lamp (RYB) with holder,230/250 volts,AC -01 set (set of three) Make :- AE/L&TOUTGOING(a) MCB, Single pole & neutral, 40 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 06 Nos (Officers Accn)(b) MCB, single pole & neutral, 10 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 1 No (Stair case lighting)(c) Slot for fixing the three phase smart prepaid meter - 07 Nos (Cost of Smart meter cost will be paid seperately under respective itemly) 31 M & L for maintenance free Chemical earthing of technology with copper bonded steel rod 3 mtr long 25.0 mm dia with 250-micron Copper bonded coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 holes of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material- polymer body & cover dimensions- 308 mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed. 32 Note:-(i) Earthing is to be done infront of the Engr-in-Charge.(ii)Test Results of earthing to be submitted by the contractor for all earthings.(iii)The Contractor shall have to give written guarantee for maintenance earth resistance of less than 1.0 Ohm for the period of 10 9ten) years after certified date of completion and shall bdeposited 2000/- per earthing as security deposit for a period of Ten (10) Years.(iv)Failing to maintain resistance of earthing less than 01.0 ohm , new earthing to be provided by the contractor with out any extra cost.(v)Necessary earth work, excavation shall be carried out in any type of soil strata, retuning, filling in and making good surronding area complete. 33 Supply and Installation of Smart Single Phase Meter of different makes (Not more than 33 % of a particular make) including polycarbonate boxes with transparent cover to view meter display with the following specifications:(a) AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 5A-60A, with 3200 impulses per KWh,LED forPhase presence & LED for Relay status, conforming to IS-16444 standard with inbuilt 865-867 MHz 6 Low PAN Mesh Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LCD based display only with compatible IP54 compliant polycarbonate box for outdoor mounting with optical port Provision on meter box. Meter Should support the following data : 15/30 min instantaneous data for Voltage, Current, Power factor, Power, Cumulative energy and frequency, monthly billing data & antitamper features. Load survey data for 45 days with 30 min integration period for kWh, Voltage, Current, frequency etc.Meter should have connect / disconnect functionality operable from prepaid billing software & shall show balance on displayThe meter should support open communication protocol DLMSwith the softwareNote :-(a) It should run the meter in both prepaid and postpaid mode(b) The meters should carry 5 year warranty.(c) OEM shall have own NABL accredited lab for testing meters as per IS 16444 and certification shall be provided during sample approval(d) The meter cost would include DCU/ Gateway and repeater cost for RF commuication meters 34 Supplying, Fixing, Commissioning and testing of configuration of cloud based prepaid software forwith following modules: (i) Meter Data Management Module: The meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. The system would support offline meter data entry.The meter data management system would capture and provide the following data:(a) 30min instantaneous data from all the meters for seven parameters- Cumulative Energy,Power, Current, Voltage, Power factor and Frequency.b) Monthly and quarterly billing survey data for cumulative energy and max demand, Load Survey Data, Tamper Events(ii) Communication module: The system should provide communication of energy data and bills via print, email.(iii) Meter Master Data : The system would support meter data repository. The system should support meter replacment process.(iv) Excel Export : The system would support export of metering and billing data in excel formatNote:- (i). Software will be compatible with all makes of smart meter & shall be CERT-IN certified from CERT approved vendors for any cyber security related threat & complying as per ENC guidelines.(ii) It shall also include recurring SMS charges, Email gateway integration charges, payment gateway charges for online meter recharge etc & shall be included in quoted rate for 2 years DLP period.(iii) Provision for comprehensive operation including periodic charges of telecom operator, smart meter billing from completion of work till the competion of defect liability period of 2 years.(iv) The software would be hosted on MEITY GCC approved server. 2 years hosting costs would be included. 35 INTERNAL WATER SUPPLY 36 S & Fchromium plated fancy type Angle cock with wall flange quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 37 S & FChromium plated fancy type two way Angle cock with wall flange quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 38 S & FChromium plated fancy type Bib cock with Aerator quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 39 S & FChromium plated fancy type Pillar cock with Aerator quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 40 S & FChromium plated fancy type Sink cock(wall mounted) with Aerator long shunk quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 41 S & F Chromium plated fancy type Wall Mixer 3 In 1 (flow rate 6 liter per minute) with flange Provision For Overhead Shower with 115mm Long Bend Pipe On Upper Side, Connecting Legs & Wall Flangescomplete all as specified and directed.Make - Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 42 SEWAGE DISPOSAL 43 Supply, laying and testing of 150mm internal diameter of double wall corrugated (DWC) high density polythylene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked(with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS 16098-2013 Part-2 complete all as specified and as directed. Note : Bedding of pipe shallbe provide as per theconstruction methods ,andshall be strictly compiled as per clause No A-4 of Annex A of IS 16098 Part II 44 Supply, laying and testing of 200mm internal diameter of double wall corrugated (DWC) high density polythylene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked(with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS 16098-2013 Part-2 complete all as specified and as directed. Note : Bedding of pipe shallbe provide as per theconstruction methods ,andshall be strictly compiled as per clause No A-4 of Annex A of IS 16098 Part II 45 SEWAGE TREATMENT PLANT(STP) 46 Supplying, Design , Construction, Hydraulic testing , Commissioning and giving satisfactory trialsSTP of capacity 10KLD consisting of PMF Technology based along with the following accessories to the desired capacity of 10 KLD rated net outputcomplete as turnkey jobwith all involved electrical and mechanical componentsfor satisfactory performance of plant andrequired treated outlet waterparameters as per E-in-Cs Br Policy No 05/ 2023 dated 04 May 2023 complete all as specified and directed(a) Construction RCC tanks of following sizes:-(i) Septic tank of size - 3.70 Mtr x 1.80 Mtr x 1.50 Mtr - 01 No(ii) PMF tank of size - 4.20 Mtr x 2.80 Mtr X 1.20 Mtr- 01 No(iii) Filter Feed tank of size- 1.70 Mtr x 0.80 Mtr x 1.50 Mtr - 01 No(iv)Treated Water tank of size- 1.70 Mtr x 0.80 Mtr x 1.50 Mtr - 01 No(v)Chamber between PMF & FFT of size- 0.45 Mtr x 0.45 Mtr x 0.45 Mtr - 01 No(vi) Manhole Chanber made out of brick work im CM 1:6 suitable size with FRP Manhole Covers of size - (600 mm x 600 mm) - 05 Nos 47 (b) Supply & laying of Stone course aggregate of following sizes:-(i) 8 size (200 mm) - 2.60 Cu mtr(ii)4 size (100 mm)- 2.60 Cu mtr(iii)2 size (50 mm) -2.60 Cu mtr(iv)Coarse Sand - 2.60 Cu mtr(c) Supply & laying of Bacterial Culture ( suitable for degrading sewage-1200.00 KG(d) Supply & plantingof saplings Canna Indica - 60 Nos(e) S & F for Non-clog submersible Raw sewege Pump, Single phase, 230 Volts, 50 Hz of discharge capacity 0.63 cum/ Hr @ 10 Mtr head complete- 02 Nos (01 W+ 01 S) (f) S & F for Submersible opern well pump set, Single phase, 230 Volts, 50 Hz for fresh treated water application discharge capacity 0.63 cum/ Hr@ 25 mtr head complete- 02 Nos (01 W+ 01 S) (g) Supply and install for heavy duty chemical dosing system plunger type suitable to injet solution with suitable capacity, working pressure10 Kg/cm2, comprising dosing pump coupled with 3 phase electric motor of suitable capacity, 1440 rpm assembly with Agitator in one motor , Agitator with stainless steel sweepblade duly FRP coated, FRP tank suitable capacity, complete unit mounted on heavy duty MS fabricated frame duly anti corrosive paint complete with chemical grade PVC NRV along with control panel for dosing pump suitable made of power coated MS fabricated box consting of LED indicater, digital Voltmeter, single phase preventor, high voltage, low voltage protection complete - 01 Job 48 (h) S & F for of PSF (Pressure sand filter) of size 250 mmin dia and height 1.30 mtr made out of FRP material suitable for withstand of 2.50 kg/cm2 pressure with multi port valve and interlinking piping - 1 Job(j) S & F for for ACF (Activated Carbon Filter) ofsize 250 mmin dia and height 1.30 mtr made out of FRP material suitable for withstand of 2.50 kg/cm2 pressure with with multi port valve and interlinking piping - 01 Job(k) S & F for UPVC Pipe of sizes 25 mm dia & 40 mm dia suitable with stand the pressure 6 kg/cm2 as required- 01 Job(l) S & F for copper conductor multistranded 3 core cable PVC insulated sheathed calble of size 2.5 Sqmm for motor connections from starter panel to motor control connector as required- 01 JobNote:-Components/ units/ Equipment/ accessory for PMF Technology based STP is as perdesign and indicative . However OEM can add/ alter/ omit the given components as per their design to achieve desired capacity and treated outlet water parameter with same technology as per E - in- Cs Branch New Dehli guidelines/ policies . 49 Supplying, Design, Construction, Hydraulic testing , Commissioning and giving satisfactory trials for Chop Whoop Winding Process MBBR/ JOHKASOU based FRP Underground Package STP along with the following accessories to the desired capacity of 30 KLD rated net output, complete as turnkey job with all involved electrical and mechanical components complete all as specified and directed for satisfactory performance of plant and required treated outlet water parametersas per E-in-Cs Br Policy No 05/ 2023 dated 04 May 2023Note:- The STP shall be designed based on the inlet & outlet parameters of E-in-Cs Branch above policy.(a)Chop Whoop Winding Process MBBR/ JOHKASOU based FRP Underground Package STP inclusive of Solid Separation, Anoxic Zone, MBBR Aeration Zone & Final Sedimentation zone Tank of size 8440 mm (L) x 2430 mm (dia) Tank- 01 No(b)Chop Whoop Winding Process based FRP Underground Intermediate Water Storage Tank 10 KL of size 4310 mm (L) X 1830 mm (dia) Tank- 02 Nos(c) With socket provision on tanks as per the design of UPVC return sludge pipe 50mm dia, PVC inlet outlet pipe 150mm dia, PVC interconnection pipe of 150mm dia, UPVC 80 mm dia, FRP Straps, Turn Buckle Wire Rope, Concrete Deadman & Eye Bolts per the diameter & length of the tank, Manhole cover as per the drawing, PVC air vent nozzle of dia 50mm, manhole cover of size 550mm dia, etc- 01 Job.(d) S & F for On-Ground LLDPE Treated Water Storage Tank of 10 KL Capacity of size2550 mm dia x 2510 Height- 01 No(e)Supply installation, testing and commissioning of cubical type Relay Based Control Panel out door type madeout of 3.15 mm thick CRCA sheetof suitable size suitable for 415V, 3 Phase, 4 wire, 50 Hz AC with necessary MCCB for incoming , copper busbar, MCB for out going & necessary DOL stater etc- 01 Job 50 (f)Twin lobe rotary Air compressor capable of delivery 56 Cum /Hr suitable volume of free air at 0.27 - 0.37 kg/sq.cm, discharge Pressure 0.2 - 0.3 kg/cm2g, Noise Level at 1.5 m distance: <70-80 (DBA),Body rotter made out of EN19 with FG260 & FG-260(CI), Silencer Fabricated with MS material.driven through V belt or directly coupled though flexible coupling to a TEFC motor of suitable capacity 1440 RPM, 415 Volts, 3 Phase,50 Hz, Pressure guages-01 No,150 mm NRV -01 No, Butterfly shut off valve, air filter, cleaner etc including 3 core copper cable multistranded connection of suitable size from starter to air compressor assembly complete all as specified and directed. 02 Nos (1W + 1S)(i)UPVC pipes 80 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing works complete all as specified- 01 Job(g) Sludge Recycling Pumpof non clog submersible sewage pump set suitable to handle domestic sewage water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set suitable with Flow Rate 9.0 m3/hr, Head 10 Mtr (1.0 HP) for operation at 415Volts frequency 50Hz, 3 Phase- 01 No (1W) (For Sludge recycling in Solid Separation zone)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor type shall be a squirrel cage induction motor with F class insulation. (ii)UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrangements complete all as specified- 01 Job(h) Pressure Sand Filter Capacity 3.0 cum/hr made out ofFRPSide Mounted of Size: 21 x 62,workingPressure 10 PSI, Filter Media, Pebbles & Filtering Sand, PVC Piping 50 mm Size (UPVC), Multiport Valve (Manual)-01 Job 51 (j)Activated Carbon Filter Capacity: 3.0 cum/hr, made out ofFRPSide Mounted of Size: 21 x 62, workingPressure 10 PSI, Filter Media: Activated Carbon 900 - 1100I/V,PVC Piping 50 mm Size (UPVC), Multiport Valve (Manual)-01 Job(k)Chlorine (Sodium Hypochlorite) Dosing Pump of Capacity 0-6 LPH, PTFE Diaphragm, single phase 230 Volts, 50 Hz including with HDPE Chlorine Dosing Drum of Capacity 100 Ltrs and necessary connections etc- 01 Job(l) Filter feed pump of non clog submersible sewage pump set suitable to handle domestic sewage water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set with Flow Rate 3.0 m3/hr, Head 15-20Mtr (1.0 HP), suitable for operation at 415 Volts, 50Hz , 3 Phase- 02 Nos (1W+1S) (For pumping into PSF & ACF Filters)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor type shall be a squirrel cage induction motor with F class insulation. (ii) UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrangementscomplete all as specified- 01 Job(m)Raw sewage Water transfer Pump of non clog submersible sewage pump set suitable to handle domestic sewage water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set with Flow Rate 9.0 m3/hr, Head 10-15 Mtr (1.0 HP) suitable for operation at 415 Volts, 50Hz , 3 Phase- 02 Nos (1W+1S) (For pumping from Raw Sewage Collection tank into the Bar Screen Chamber)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor (k) Ctype shall be a squirrel cage induction motor with F class insulation. (ii)UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrandements complete all as specified- 01 Job 52 (n) Treated Water transfer Pump of Monoblock pump set suitable to handle domestic treated water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set with Flow Rate 9.0 m3/hr, Head 10-15 Mtr (1.0 HP) suitable for operation at 415 Volts, 50Hz , 3 Phase (1W+1S) (For pumping from treated water zone to reuse)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor type shall be a squirrel cage induction motor with F class insulation. (ii)UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrandements complete all as specified- 01 Job(o) Fine bar Screen with chamber (manual) of SS 304 for screening 5 to 6 mm particles of size 1.0 Mtr x 1.0 Mtr at inlet of MBBR tank- 01 Job 53 Note : - (i)The Package STP tank shall be made from 100% FRP Material through Chop Whoop Winding Process with compliance and certification/approval in UL 1316 from the UL LLC that is Underwriters Laboratories LLC.(ii)The FRP tanks shall be made using Isopthalic Unsaturated Polyester Resin.(iii) The Sewage Treatment Plant system shall have a valid certificate of a Green product from a reputed Government or Third party having authority to certify like CII, IGBC, Assocham or any other body having competence in issuing such certificates.(iv)The shell thickness of the tank shall be between 6.50 mm to 7.50 mm (±0.5 mm) & Dish end thickness must be 11 mm and above made only from 100% FRP material(v)Technology must be empanelled in CPHEEO Sewage Manual.(vi)Minimum Hydraulic Retention time of the total Package STP system/tank must be 22.00 hours.(vii)Minimum sludge handling should only be once a year(viii)STP must function from minimum load of 5 - 10% to 100%. (Minimum load to Peak Load)(ix)The STP must have an anoxic zone for denitrifuication(x)Minimum volume of Intermediate Water Storage tank in FRP MOC must be 10 KL(xi)Minimum volume of Treated Water Storage tank in LLDPE MOC must be 10 KL 54 Material and Labour for Motor ControlLT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. Motor Control LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) complete including the following accessories:-. 55 IN COMING:-(i)Copper strip busbar of 60 Amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos(ii) On load change over Switch TPN of capacity 32Amps - 01 No (iii) 4 Pole MCB of capacity 5-32 Amps 10 KA breaking capacity C curve-01 No(iv)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three) (v)Digital Multifunctional meter , flush mounting type with CT’sand selector switch – 01 set.OUT GOING :-(b) MCB SPN 5-32 Amps 10 KA breaking capacity C curve-04 Nos(c) DOL starter single phase with suitable relay range conforming to IS -1347(Part IV) suitable for discharge capacity 6.4 LPM ( 0.38 Cumt/Hr)at 10/25 Mtr head, 0.50 HP, including overload relay, auto timer, indicating lamps (LED) etc complete -04 Nos 56 Supply and laying fordouble wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 (Part I and II) for protection of underground cables of size nominal outer dia 63 mm & nominal inner dia 50 mm dia with all fittings laid in trenches / road/ nallah or fixed along wall for cable protection all as specified. 57 HOT WATER SUPPLY 58 Supply and installation,commissioning and testing at roof top of building Solar water heating system (Flate Plate Collector) based on indirect transfer of heat of capacity 100Ltr per day with electrical back up of 2 KWas per manufacturers recommednations includinghot water storage tank of capacity 300 ltrs and of 20 guage thickness stainless steel plate (having insulation of rock wool ) mineral wool 100 mm thick & cladding with aluminium sheet 24 SWG complete all as specified and directed. 59 ROAD/ PATH 60 Material and labour for providing and painting 2.5 mm thick road marking strip (retro reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser,propane tank heater and profile shoe heater, driven by experienced operator on road surace including all cost of material, labour, T&P, cleaning of road surface of dirt, seals, ils, grease and foreign material etc. complete all as specified and directed. 61 EXTERNAL ELECTRIFICATION 62 Supply and fixingfor Cable route indicator / Marker made up of PCC Block in cement mortar 1:3:6 ( 20 mm graded aggregrate ) of size 900 x 300x 100 mm thick with DANGER/ 11 KV CABLE/ MES embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work ( as required / ordered at site) complete all as specified and as directed. 63 S upply and fixingfor Cable route indicator / Marker made up of PCC Block in cement mortar 1:3:6 (20 mm graded aggregrate) of size 900 x 300x 100 mm thick with DANGER/ LT 433 VOLTS CABLE/ MES embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work (as required/ ordered at site) complete all as specified and as directed. 64 Supply, installation, Testing and commissioning of Outdoor type (IP 54), 03 way RMU (Ring Main Unit) 11 KV, 630 Amps, 21kA-3 Sec,IP54 SF6 insulated, One side Extensible,consisting of One No (01) motorised vacuum circuit breaker (Incomer) and Twor Nos (02) motorised vacuum circuit breaker (Outgoing) & Metering Panel Bus PT with Top LV, Battery & Battery charger, Ethernet switch & LIU (Configuration VVV+M), inside robotically welded stainless steel 304 (Non Ferrite non Magnetic Grade) tank having min thickness 2.5 +/- 0.5mm with IP 67 degree of protection and enhanced BIL of 75 kVp internally to manager voltage surges and Air Insulated Metering Module of Class-0.5. RMU should be provided with internal busbars, as well as earthing busbars of electrolytic grade copper, padlock provisions & complete with all accessories. The complete RMU must be type tested for Internal arc21KA for 1 sec with AFLR Classification for Gas tank & Cable Chamber as per IEC 62271-200. HT RMU shall preferably have on-site-repairability features such as site replaceable bushing/ coupling/ mechanism and gas refilling to have very less downtime in the event of bushing breakage and restoration can be done at site immediately without sending the RMU to OEM Works, the Vaccum Interrupter must RMU manufacturers own make. The earthing busbar shall be provided inside each cable compartment for solid earthing of cable shields. The outer hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protectioncomplete all as specified and as directed. The unit shall include the following with all necessary standard fitting as required at site.-Make of RMU shall be limited to : ABB/ SIEMENS/ SCHNEIDER INFRASTRUCTURE(Channel partner/ System Integrator/ Authourized Partner/ License partner make RMU shall not be accepted.) 65 (a) Vacuum Circuit Breaker consist of following accessories :-(i)Microprocessor based Numerical Protection Relay for Circuit Breakers - REF615, Feeder Protection and Control Relay, Protections 50, 51, 50N, 51N, 46, 49, 67, 67N, 32, 27, 59, 25, 81U, 81O, 95 Measurement for 3I,I0,3U,U0,Kw,KVA,PF,Hz,Kwh, 16 DI + 10 DO, One front RJ45 Port, One Rear RJ45 Port for IEC-61850 Protocol, Drawout Type with CT Shorting feature, Graphical LCD Display(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator on the gas tank.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO amd suitable for 10,000 mechanical operation.(v)CT shall be minimum 50-100/1A ,2.5VA , 5P10 - 3 Nos. for protection(vi)CT shall be minimum 50-100/1A ,2.5VA , Class 0.5 - 3 Nos. for metering(vii)Right angle boot to be provided in each module(viii)2 x12 Volts, 26 AH Battary with Charger - 1 Set(ix)Bus VT shall be 11KV/V3/110V/V3 ,20VA , Class 0.5 - 3 Nos. for metering(x)Auxiliary VT shall be 11KV/230 ,500VA for AC supply input to Battary Charger.(xi)Capacitive voltage indication fixed type system as per IE(xii)Interlocked Cable box for front termination of the cable suitable upto 3 core 120 Sqmm,11 KV XLPE cable (IP3X). Safety interlocked to prevent access to cable termination in live-condition. 66 (xiii)Right angle boots (push on type)(xiv)Cable covers with self Interlocking mechanism between doors, earth switch, disconnector & VCB.(xv)Necessay interclocking arrangement for safety and operations(xvi)One No. Operationg Handle for Manual Operation and one no. manometer(xvii)Safety Interlocks Shall be provided as per relevant IEC/IS Standards and Manufacturers directions.(xviii)Above switchgear shall confirm to all relevant IEC/IS Standards. 67 Supply, installation, commissioning and testing of transformer of capacity 315 KVA, confirming to IS 1180 (Part-1)- 2014 with latest amendment No 4, BEE 3 star rated, EEL 3, step down Outdoor type complete with standard fittings, HT 11 KV 3 phase LT 433 vols, 3 phase, 4 wire corrugated 7 position off circuit tape links of rating + 7.5 to -7.5% @ 2.5% by means of hand operated off load tap changer including necessary control wiringtransformer copper wound, double wound, oil immersed naturally cooled with external cooling tubes core type delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector symbol Dyn -11 (vector group with neutral brought on secondary side (LV side) and the maximum temperature rises should not exceed 40 degree centigrade in oil and 45 degree centigrade in HV/LV winding ring measured by resistance after continuous full load run in ambient temp as per IS -2026 per transformer, IS-3639 for fitting & accessories, IS-2099 for high voltage porcelain bushings and the transformer shall be comprised with the following standard fitting with on load tappings on HT side to vary secondary voltage within limit all as per IS -1180 complete all as specified and as directed wit latest policy for following:- 68 Note 01:- (i)Three Nos porcelain bushing suitable for 11 KV on HV side, complete with copper rods, nuts and washers with cable end box.(ii)Four Nos porcelain bushing suitable for 433V on LV side, complete with copper rods, nuts and washers with cable end box.(iii)Monogram plate.(iv)Oil conservator with filter and drain plug.(v)Prismatic/transparent oil gauge.(vi)De-hydrating breather with first fill of dehydrating agent (silica gel).(vii)Thermometer pocket.(viii)Air release plug.(ix) Inspection cover(x) Lifting lugs for complete transformer(xi)Top cover lifting lugs(xii) Jacking lugs(xiii) Top filter valve(xiv)Instruction plate(xv)Drain cum bottom filter valves(xvi)Earthing terminal and stud(xvii)Off load tap changer (xviii)Rating and Diagram plate(xix) Buchholz relay with alarm & trip contacts.(xx)Bi directional roller wheel -04 Nos. 69 (xxi)Marshalling box for termination of all alarm & trip controls of the transformer.(xxii)WTI (Winding temperature indicator) with alarm & trip contact(xxiii)Oil surge relay.(xxiv)Shut off valve for buchholz relay.(xxv) OTI (Oil temperature indicator) dial type of 150 mm with alarm and trip contact capillary type.(xxvi)Two earthing terminals on tank cover to facilitate fixing of 50x6 mm galvanised iron earth strip for earthing of body.(xxvii) Necessary PCC foundation/ block masonry platform as directed by OEM. (xxviii)First filling of new and unused transformer oil, IS-335 marked.Note 02 :- (a)The rates include for supplying transformers with standard fittings and installing complete including all jointing materials, connecting with electrical system, earthing, testing and commissioning. (b) The transformer will have its initial oil filling to appropriate level (cost of oil including testing with desired dielectric strength included in supplied and installed rates, cost of PCC foundation shall be included as per manufacturer drawing) 70 Supply, fixing, installing and commissioning of octagonal Galvanised street light pole 9 mtr long, top dia 70 mm, bottom dia 155 mm, sheet thickness 3 mm and base plate dimensions 260 x 260 x16 mm thickness with door locking arrangement for provision ofterminal plate consisting ofMCB TPN 10 Amps, with necessary electrical connections including 04 Nos foundation with J type foundation bolts -04 Nos of sizeas per manufacturer design should be hot dipped galvanized andGI single arm bracket (Ornamental type) complete with door locking arrangement complete all as specified and directed.Note:- Necessary Excavation of Soil, RCC foundation as per manufacture recommendation including foundation bolts etc deemed to be included in quoted rate. 71 Supply ,fabrication, installation and testing of LT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) .All extension link/ inter connection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:- (Transformer main LT Panel) 72 Note:- Rate of earthwork and PCC work etc are deemed to be inclusive in this item.IN COMING:a)Copper strip busbar of 1000 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nosb)4 pole MCCB 500 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.(c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider.(d)Digital Ammeter of range (0- 250) Amps, flush mounting type with CT’s of ratio 250/5 and selector switch – 01 set.(e)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. 73 OUTGOING:- (a)4 Pole MCCB 125 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No (MWO/ WO accn Bldg Panel No 1)(b)4 Pole MCCB 160 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 04 Nos (for Sgt Accn Panel No 2, 3, APFC panel & Spare)(c)4 Pole MCCB 32 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No(d)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter - 01 No. 74 Supply ,fabrication, installation and testing of LT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) .All extension link/ inter connection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:- (forMWO/WO Accn LT Bldg Panel No1)Note:- Rate of earthwork and PCC work etc are deemed to be inclusive in this item. 75 IN COMING:-a)Copper strip busbar of 250 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nosb)4 pole MCCB 125 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.(c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider.(d)Digital Ammeter of range (0- 250) Amps, flush mounting type with CT’s of ratio 250/5 and selector switch – 01 set.(e)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. 76 OUTGOING:- (a)4 Pole MCCB 63 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 03 Nos (forMWO accn Bldg supply- 2 Nos & Spare)(b)4 Pole MCCB 32 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 01 No (Street light)(c) Multifunctional Digial type Astronomical function Time switch (Astro type having longitude and latitude of Indian cities memory) 240 volts AC Single Phase - 01 No(d) Power contractor 4 Pole, 32 Amps,415 Volts, 50 Hz - 01 No (e)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter - 01 No. 77 Supply ,fabrication, installation and testing of LT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) .All extension link/ inter connection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:-(for Sgt accn Bldg Panel No 2 & 3) 78 Note:- Rate of earthwork and PCC work etc are deemed to be inclusive in this item.IN COMING:- a)Copper strip busbar of 400 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nosb)4 pole MCCB 160 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.(c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider.(d)Digital Ammeter of range (0- 250) Amps, flush mounting type with CT’s of ratio 250/5 and selector switch – 01 set.(e)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. 79 OUTGOING:- (a)4 Pole MCCB 100 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 03 Nos ( Sgt Accn bldg supply- 02 Nos & Spare)(b)4 Pole MCCB 32 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 01 No(e)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter - 01 No. 80 Material and labourfor Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure for cable protection and making good as existing complete all as specified and as directed. 81 Material and labourfor maintenance free Chemical earthing of technology 3 mtr long20 mm dia with 250-micron Copper coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 holes of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material- polymer body & cover dimensions- 308 mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed. 82 Note:- (i) Earthing is to be done infront of the Engr-in-Charge.(ii)Test Results of earthing to be submitted by the contractor for all earthings.(iii)The Contractor shall have to give written guarantee for maintenance earth resistance of less than 1.0 Ohm for the period of 10 9ten) years after certified date of completion and shall bdeposited 2000/- per earthing as security deposit for a period of Ten (10) Years.(iv)Failing to maintain resistance of earthing less than 1.0 ohm , new earthing to be provided by the contractor with out any extra cost.(v)Necessary earth work, excavation shall be carried out in any type of soil strata, retuning, filling in and making good surronding area complete. 83 EXTERNAL WATER SUPPLY 84 Supply, Laying, jointing & testing of 150mm dia (6) Ductile iron (DI), pressure pipes with spigot and socket ends, centrifugally cast, class K-7, with cement mortar lining in inner side as per IS:8329/ 2000 (latest revision) and other relevant standards and metallic zinc coating followed by a finishing layer ofepoxy paint in outer side,suitable for push on joint(rubber gasket joint) including rubber gasket in any length with inside cement mortar lining laid in trenches/ over masonry pillarcomplete all as specified and as directed 85 Supply, Laying, jointing & testing of 100mm dia (4) Ductile iron (DI), pressure pipes with spigot and socket ends, centrifugally cast, class K-7, with cement mortar lining in inner side as per IS:8329/ 2000 (latest revision) and other relevant standards and metallic zinc coating followed by a finishing layer ofepoxy paint in outer side,suitable for push on joint(rubber gasket joint) including rubber gasket in any length with inside cement mortar lining laid in trenches/ over masonry pillarcomplete all as specified and as directed.Notes foraboveItems No 53 & 54 :- (i) Excavation & Earthwork, shall be measured and paid separately. (ii) The necessary Exise duty exemption certificate from Deputy Commissioner of respective district shall be arranged by the GE for DI pipe.The contractor shall quote the rates against these items considering Exise exemption. (iii) The quoted rate shall also be deemed to include for provision of joints and jointing material for laying pipes. For jointing ofpipe fittings or taking branch connection, provision of joints and jointing material shall be measured and paid separately. (iv) . Before laying of pipe line contractor has to submit layout diagram as per level difference and ensure proper alignment of the pipe. 86 Material and Labour for Ductile iron fitting for spigot socket pipe such as bends (any type, radius and angle) tapers any type (straight, bend increasing, decreasing or double socket etc). Tee pieces single branch. Y junction, double branch, cross (All socket or socket and spigot) collars, restrained joint, mechanical joint, caps & plugs 80 mm to 250 mm dia bore including cutting and jointing new positions complete all as specified and as directed 87 Material and Labour forcutting CI pipes 150 / 80mm in position for insertion and including provision of Tee branches etcfor 80/50 mm dia pipe line complete all as specified and directed 88 Material and labour for construction of brick masonry valve pit of internal size 90cm x 90cm x 90cm suitable for gate valves/ sluice valve upto 150 mm including necessary excavation and earth work, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 50mmx50mmx6mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock complete all as specified and directed.Note:- (i) Brick wall shall be 23 cm thick built in cement mortar (1:6)(ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450 mm from top shall be 20 mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds(iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls (iv) PCC coping shall be 15 cm thick in cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC(v) Three coats of white wash to internal surfaces of valve pit shall be provided(vi) Depth of valve pit shall be reckoned from the top of PCC in foundation 89 Material and labour for construction of brick masonry valve pit of internal size 60cm x 60cm x 70cm suitable for gate valves/ sluice valve upto 150 mm including necessary excavation and earth work, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock complete all as specified and directed.Note:- (i) Brick wall shall be 23 cm thick built in cement mortar (1:6)(ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450 mm from top shall be 20 mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds(iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls (iv) PCC coping shall be 15 cm thick in cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC(v) Three coats of white wash to internal surfaces of valve pit shall be provided(vi) Depth of valve pit shall be reckoned from the top of PCC in foundation 90 RAIN WATER HARVESTING 91 Supply and Fixing 150mm bore PVC slotted pipes double socketed in any length with suitable joints, laid in bore hole for recharge pit and like complete all as specified and directed 92 Boring 300mm dia for Bored cast in situ piles 16 metres in any kind of soil/soft rock and getting out and disposal of spoil to a distance 50 metres using suitable method complete all as specified and directed 93 FIRE FIGHTING SYSTEM 94 Supply and Fixing for 3 kg light-weight squeeze grip CO2 type fire extinguisher, conforming to IS 15683: 2006, with CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed Make: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 95 Supply and Fixing for 5 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directedMake: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 96 Supply and Fixing for 9 litre mechanical foam type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted with gunmetal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directedMake: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 97 Supply and Fixing for 9 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directedMake: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 98 Supply and Fixing for Galvanized mild steel Fire bucket (Filled with dry sand & water) conforming to IS 2546: 1974 round bottom type enamel painted, white inside & Red out side and Letter FIRE in black out side and handle with mounting bracket complete as specified and directed 99 Supply and Fixing for Galvanized mild steel Fire hook bracket with 3 mtr bamboo handle painted with red colourcomplete as specified and directed 100 Supply and Fixing for Galvanized mild steel Fire Beater bracket with 3 mtr bamboo handle painted with red colourcomplete as specified and directed
Contract Date: Mar 11, 2026 Contract Value : 14.98 Crore
Statutory Bodies & Commissions/Committees No of Bidders 5
35.
Defence #9618268 AOC
Tender For Special Repair To Bldg No Ts-02 (01 To 04) Or Md Accn At Mandir Line Of Static Wksp Eme Under Ge (Awc) Mhow; 1 Demolition of un-reinforced Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. 2 Demolition of cement concrete (reinforced) as in roof, floors (other than ground floor) beams, staircase, landing, chajjas and similar suspended work complete. 3 Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) and rubbish of the premises complete all as specified and directed. 4 M&L for Scratch free, double charged, vitrified ceramic tiles9 to 10mm thick (square or rectangular) area of each tile not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layerin CM 1:6 complete all as specified and as directed. 5 M&L for Coloured Non Skid ceramic joint freetiles 7 to 8 mm thick (Square/ Rectangular) area of each tile exceeding 0.06 Sq. M but not exceeding 0.18 Sq. M, in floors etc,including 15 thick screed bedset and jointed in neat cement slurry and pointedin white or coloured cement to match the shade of the tile complete all as specified and as directed. 6 S&F Glazed ceramic tiles in vertical surface 450 x 350x 7 mm thick ,including 10 mm thick secreed bed set and jointed in neat cement slurry and pointed in white or cloured cement complete all as specified and as directed.Note : Rate includes for cuttingfor offsetsetc) complete all as specified and as directed. 7 M&L for Hard core of guage n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed. 8 M & L for 75 mm thick PCC 1:3:6 type C2 (Using 40mm graded granite stone aggregate) as in plinth protection finishd even and smooth with out using extra cement complete all asspecified and directed. 9 M&L for 50 mm thick cement concrete type B-1, 1:2:4 (using 20mm graded aggregate) surface finished even and smooth without using extra cement complete all as specified and directed. 10 Material and Labour Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;complete all as specified and directed. 11 M&L for Pre Cast Cement Concrete 1:2:4 type B1 (using 20 mm graded aggregate) as in Kitchen platform and Cover slab for manholes etc set in cement mortor 1:4 including use and waste necessary form work (Reinforced shall be measured and paid seprately) all as specefied 12 M&L for cement concrete Type C21:2:440 mm graded stone aggegate as in footingscolumns ,beams walls CM1:4 including use and waste necessary form work (Reinforced shall be measured and paid seprately) all as complete all as specified and directed. 13 M & L for Form work to sides of foundation / slabs / base of columns plinth beams and similar work with fair finished surface complete all as directed. 14 M&L for mild steel TMT bars 10mm dia and over, cut to length bent to shap required including cranking, bending spirally for hooping for columnshooking ends and binding with and including mild steel wire (annealed not less than 0.9 mm dia or securing with clips complete all as specified and directed. 15 Description all as per ser item No. 14.00 above but 5mm dia and over upto and incl 10 mm dia in spacers, stirrups and binders complete all as specified and directed. 16 M&L for granite slabs 20mm thick machine cut bedded laid over cement screed 15mm thick in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of slab incl grinding moulding rounding chamfering and polishing complete all as specified and directed. 17 M&L for machine cut Cudappastone slab flooring 20-25mm thick laid over and including 20mm thick screed bed in CM 1:6and jointed with grey cement slurry mixed with pigments to match the shade of the slab including rubbing and polishing with beeswax polish complete all as specified and as directed. 18 M&L for Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed. 19 Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc complete all as specified and directed. 20 M & L for brick work with sub-class `B bricks, straight or curved burnt clay brickson plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and directed. 21 M&L for brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1: 4 complete all as specified and directed. 22 Taking down cement plaster on wall of any description incl racking out joints for key, scrubbing with water etc. complete all as specified and directed. 23 M & L for rendering 15mm thick in cement mortor 1:4 on concrete or brick wall surfaces, finished even and smooth without using extra cement, mixed with WPC @ at 3% by weight of cement (IWPC measured and paid separately) complete all as specified and directed. 24 Supply only integral water proofing compound. 25 M & L for rendering 10mm thick in cement mortor 1:6 on Brick wall surfaces, finished even and smooth without using extra cement complete all as specified and directed. 26 M&L for 15 mm thick cement plaster in cement mortar 1:6 on brick or concrete surface etc. on wall finished even and smooth without using extra cement, all as specified . 27 Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundation etc or for shafts wells, cesspits, manholes, pier holes etc not exc 10sqm on plan and getting out in hard/dense soil complete all as specified and directed. 28 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with all kind of soil complete all as specified and directed. 29 M&L for removing excavated surplus soil n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed. 30 M&L for PCC type D2 1:4:8 (using 40mm graded stone aggregate) as in foundations, filling and mass Concrete complete all as specified and directed. 31 Taking down chowkats with shutters (without taking off shutters from the frameexc 1.5 Sqm and n.exc 4 Sqm each complete all as specified and directed. 32 Description all as per ser item No. 31.00 above in before but n exc 1.5 Sqm complete all as specified and directed. 33 S&F Pressed steel frames 125x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified and directed. 34 S&F pressed steel door frames of size 105 x 60mm, made of 1.25mm thick sheet, for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate,etc complete all as specified as directed. 35 S&F IInd class hardwood panelled shutters of 40mm thick (any number of panesl) with panels of timber flat on both sides (feathered edged0 or of veneeered particle boad medium density, wood particle board with commercial face veneers, complete all as specified and as directed. 36 Providing“RAJSHRI” Brand Factory Made 35 mm thick 100% Solid WPC ( Wood polymer Composite ) Laminated Flush Door Shutter of required size comprising ofvirgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cbmmanufactured by RAJSHRI an ISO 9001 - 2015 Certified Company, having good screw holding capacity ( Screw Withdrawal strength of 50 N ( Face ) & 1100 N ( Edge ), Minimum Compissive of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutterand fixing stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws,incl chowkhtas All as per direction of Engineer -In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company :For WC/Bathroom/Toilet/Kitchen/Balcony Doors. 37 Providing30 mm thick RAJSHRI BRAND FACTORY MADE WIRE MESHSOLID WPCDOOR SHUTTER consisting ofDensity 500 Kg /CbmManufactured by an ISO-9001-2015 certified Company , Door to be panelled with SS mosquito Mesh and XTN aluminium Mesh for additional strength and safety purpose.(confirming as per IS:4020). The door should be water proof, termite proof, fire retardant and having screw holding capacity. Door to be fixed to frame with 3 nos. M.S powder coated butt hingessize 100mm*25mm*2mm and 32mm long steel screws drilled suitable to pass through both the walls of the M.S tube.Other hardwares should be fixed with 19*6mm size steel screws etc. Complete as per direction of Engineer-in -charge, manufacturers specification & drawings. 38 Material and labour Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specificationall as directed. 39 Material and labour Factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside complete all as specifed and as directed. 40 Material and labour Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed withn wooden beading or with nuts and bolts to existing steel windows/wooden windows complete all as specifed and as directed. 41 S & F powder coated aluminium ventilator cross section conforming to IS 63.5x38.10x1.5mm consisting of two partions upper portion shall have louvers with 3mm thick pin headed glass and aluminium wire cloth 0.30mm nominal dia of wire and average width of aperture 1.56m fixed with aluminium beads and securing on outer face of frame and lower portion of ventilation shall be fixed with 3mm thick pin headed glass with IDPE rubber gasket including aluminium beads, including preparation of jombs all around in CM 1:3 finishing even and smooth complete all as specified and directed. 42 S & F Powder coated aluminium sliding glazedwindows with three track shutter sliding (two shutters glazed and one shutterwire mesh) shall be following specification complete all as specified and as directed by Engr-in-charge.(i)Windows frame of cross section 101mm x 44mm x 1.5mm thick.(ii)Three way track for sliding shutters of cross section91.8mm x 31.75mm x1.1mm thick.(iii)Sliding shutter frame of cross section40 x 18 x 1mm thick.(iv)4 mm thick tintedglass superior quality.(v) IDPE Rubber guasket for fixing of glass.(vi)Locking cleats per shutter -01 Nos.(vii)Sliding rollers per shutter - 02 Nos.including satety steel grill(viii) Aluminium wire cloth 0.30mm nominal dia of wire and average width of aperture 1.56mm for shutters 01 Nos. 43 M&L for 5.5mm thick sheetglassn exc 0.50sqm in area to be fixed in Alluminiumwindows complete all as specifed and as directed. 44 S&F 300mm length, aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specifed and as directed. 45 S&F 250 mm length, aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specifed and as directed. 46 S&F100 mm size of Butt hinges, medium weight cold rolled mild steel complete door etc complete all as specified and directed. 47 S&F aluminium anodised barrel tower bolts of extruded section with 100 mm long bolt, all as specified . 48 S&F aluminium anodised barrel tower bolts of extruded section with 200 mm long bolt, all as specified . 49 S&F aluminium anodised barrel tower bolts of extruded section with 150 mm long bolt, all as specified . 50 S&F Extruded aluminium alloy handles fabricated type anodised 150mm size complete all as directed and specifiedand as directed. 51 S&F Extruded aluminium alloy handles fabricated type anodised 100mm size complete all as specified and as directed. 52 M&L for floor door stopper of brass body and tongue, anodised, with hard drawn steel spring, 140mm long, fixed in floor complete all as specified & as directed. 53 S&F hasp and staple 125mm, safety type, aluminium anodised with alu hinge pin incl bolt to hinge plate and fixed with screws all as specified and as directed. 54 M&L for 2nd Class hardwood plain fillets, square or triangular in section, clean swan, secured with nails or brads, croos sectional area exc 13 Sqcm but Not Exc 25 Sqcm complete all as specified and directed. 55 Material and labour Second class hard wood Plain fillets square, rectangular or triangular in section clean swan, Exc 6 & n exc 13 sq. cm secured with mails brads,Wooden Barear 25X40mmcomplete all as specifed and as directed. 56 Material and labour 19mm thick Particles boards, medium density, flat pressed, single layer type or three layer, BWR grade complete all as specified and directed. 57 S&F in repairs 18/19mm thick prelaminatedparticle board interior grade / sprelaminated one side with decorative choice lamination and other side balancing white lamination fixed with nails to timber frame work complete all as specified and directed. 58 Extra over rates of block board or veneered particle board of (18/19mm ) for external teak wood lipping 6mm thick fixed with nails complete all as specified and directed. 59 S & F Continuous (piano) hinges,mild steel, bright finish or electro galvanised, Width of flaps (when open) in 30 mm etc complete all as specified and directed. 60 S & F 75mm thick Extruded aluminium alloy handles, fabricated type,anodised, etc complete all as specified and directed. 61 S & F brass 2-levers locks for cupboard, grade I of size 50mm complete all as specified and directed. 62 S & F 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finished and brass polished complete all as specified and directed. 63 S&F fanlight magnetic catch with 14mm catch cast brass and fixed to cupboard shutters all as specified and as directed 64 S& F 18 mm thick factory made PVC sheet one side pre laminated sheet kitchen cabinet shutter/cupboard shutter.The 18mm thick sheet shutter bent at 90 degree and finish all edges at level for making edge lipping bending for 0.5 mm thick PVC sheet lipping at all four edges using bodning etc complete all as specified and directed. 65 S&Ffactory made PVC shelf/partition of required size consisting of panel of 12 mm thick celuka PVC ply and for supporting the hold of shelf/partition and shall provide 3 edges in size 18mm x 18mm as per required length the front side of the edge visible in the fronth of the self / partition to be edge lipped by 18mm width x 1 mm thick PVC sheet of density 600kg/cum manufactured by ISO 9001-2015 Certified company using solvent cement etc complete all as specified and as directed. 66 S&F stainless steel shelf closing hinges 75 mm size for PVC door shutters complete all as specified and directed 67 S&F 50 x 15 mm size magnet door catcher for closing for PVC door shutter complete all as specifid and directed . 68 S& F 100 mm size MS mat/glossy finish handle complete all as specfied and directed . 69 S&F modular type stainless steel cutlery basket size 20 x 19 x 4 inches (dia of wire not less than 3.00 mm) of any shape withside sliding roller clip and silding rails on both side fixed with steel screws incl all fixing arrangements complete all as specified and directed. 70 Description all as per ser item No. 69.00 above but cup and saucer basket size 20 x 17 x 4 inches complete all as specified and directed. 71 Description all as per ser item No. 69.00 above but plain basket size 20 x 19 x 6 inches complete all as specified and directed. 72 Description all as per ser item No. 69.00above but grain basket size 20 x 17 x 6 inches complete all as specified and directed. 73 Description all as per ser item No. 69.00 above but thali basket size 20 x 19 x 8 inches complete all as specified and directed. 74 Description all as per ser item No. 69.00above but plain basket size 20 x 17 x 8 inches complete all as specified and directed. 75 M & L forform work to sides of concrete foundation including rafts, footings, foundation beams, bases of columns etc for fair finished surface complete all as specified. 76 S&F Harrison rails ,mildstainless steel curtain rod cromium platedwith brackets 25mm dia including necesary SS clamp complete all as specified & asdirected. 77 Taking down 15mm bore steel tubing and connections in any position, Complete all as specified and directed. 78 Taking down 20mm bore steel tubing and connections in any position, Complete all as specified and directed. 79 Cutting chases, pinning in, making good to facings where required & pointing in cement mortar 1:3 for concealed water tubing, etc.& making good, cutting not exc 10 cm grith 80 Supplying and fixing of 16mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including provision of special fittings ( Unions, elbow, Tee, Male threaded brass adaptor, Female threaded brass adaptor, Tank adaptor etc), complete all as specified 81 Supplying and fixing of 20mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including provision of special fittings ( Unions, elbow, Tee, Male threaded brass adaptor, Female threaded brass adaptor, Tank adaptor etc), complete all as specified 82 M&L for 20 mm bore GI Tubing medium grade with all fittings fixed to wall/ ceiling or in floor complete as specified and directed. 83 S&F in repair rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 2000 ltrs capacity hoisted and fixed in position all as specified including dismantling old500 ltr water tank complete all as specified and directed. 84 S&F 20 mm dia brass ball valve, high pressure with polythene float and fly-nut complete, screwed for iron pipe or brass ferrule fixed in repair complete all as specified and directed. 85 S&F in repair 20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 86 S & Fin repair 15mm bore Bib taps, chromium plated cast copper alloy but fancy type, screwed down, screwed for iron pipe or for brass ferrule complete allas specified and directed. 87 S&F in repairs 15 mm diafancy type stop valves/ angle cock chromium plated screwed down, high pressure,screwed both ends for iron pipe or for unions and fixed complete allas specified and directed. 88 S&F Long body CP Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. 89 S&F angular stop valves, cast copper alloy, screwed down, high pre-ssure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. 90 S&F Bib taps, cast copper alloy with crutch or butterfly handle, sc-rewed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. 91 S&F Brass CP wall mixer for mixing hot & cold water screwed down for iron pipe and fixedcomplete all as specified and as directed. 92 S&F Brass CP Tubular towel rail, 20mm dia, D type, 60cm long between flanges fixedcomplete all as specified and as directed. 93 S&F chromium plated shower roses 125mm sizes with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed. 94 M&L for Health faucet (ABS Bpdy) mild steel chromium plated suitable for 15mm dia pipe 1.25 M long flexible tube and ABS wall Hook including making connection and fixed in position with two way tap complete all as specified and as directed. 95 S&Fin repairs stainless steel Kitchen sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mmincluding necessary PVC outlet pipe and coupling complete all as specified and directed. 96 S & F in repair stainless steel plate rack 31 X 36 X 10 made up of 1mm thick sheet (Non magnetic) complete all as specified and directed. 97 S&F in repairs Vitreous China squatting pan , Orissa pattern size 580 X 440 mm white with intgrel footrest (excluding flushing cistern 10 ltr capacity & flush pipe) with 110mm dia PVC SWR P or S trap, fixing of cistern, complete including provision of cement concrete all as specified and directed. 98 S&F in repairs for vitreous china wash basin, white, flat back size 550 x 400mm including 01 Nos cast copper alloy 15mm CP fancy type pillartap, 01 Nos 32mm waste coupling , one pair of MS bracket, cuttingfor and pinning in ends of brackets complete all as specified and directed. 99 Supply and fix in repairs PVC valveless syphonic action type flushing cistern 10 lit capacity low level white with inlet, ball valve, float and handle including brackets and32mm PVC flush pipe complete all as specified and directed. 100 S&F in repairs PVC connection 15mm dia, 45 Cms long with brass ferrules on both ends fixed complete all as specified and directed. 101 S & F brass chromium plated tubular towel rail 20 mm dia ‘D’ type 60 cm long between flanges ofbrass chromium plated complete all as specified and directed. 102 Supply and Fix in repairs PTMT Shelf of weight not less than 300 gms with soap dish (tray) fixed with and including Chromium plated brass screws and wooden / plastic cleats etc., complete all as specified and as directed. 103 S&F in repairs 600mmx450mm belvelled edge looking mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood with PVC / alluminium frame and fixed to wooden plugs with chromum plated brass screws, cup washers, complete all specified and directed. 104 S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed. 105 S&F in repair 550mmx350mm PVC Cabinet Mirror with shelves of selected quality glass and fixed on walls to wooden plugs with chromium plated brass screws, cup washers complete all specified and directed. 106 S & FPVC( SWR ) pipes 110mm dia single socketed , in any lengthwith rubber ring joints as rainwater, soil waste and vent pipe (with all fittings) fixed to wall or laid in trenches incl taking down existing pipe complete all as specified and directed. 107 S & FPVC( SWR ) pipes 75mm dia single socketed , in any lengthwith rubber ring joints as rainwater, soil waste and vent pipe (with all fittings) fixed to wall or laid in trenches incl taking down complete all as specified and directed. 108 S&F in repair PVC (SWR) bends any radius 110mm bore complete all specified and directed. 109 S&F in repair PVC (SWR) bends with access door any radius 110mm bore complete all specified and directed. 110 S&F PVC (SWR) junction single (single T) equal or unequal with access door of bore 110mm complete all specified and directed. 111 S&F PVC(SWR) vent cowl 110mm bore complete all specified and directed. 112 S&F PVC (SWR)bends any radious 75 mm dia complete all specified and directed. 113 S&F PVC (SWR)bends with access door any radious 75 mm dia complete all specified and directed. 114 S&F PVC (SWR) junction single (single T) equal or unequal of bore75mm complete all specified and directed. 115 S & F in repairs PVC (SWR) Floor trap/Nahani trap plain or multi with stainless steel grating incl joinig to waste pipe with solvent cement joint dia of outlet 75 mm bore complete all as specified and directed. 116 S&F PVC (SWR) junction single (single T) equal or unequal with access door of bore75mm complete all specified and directed. 117 S&F in repair PVC (SWR) floor trap 75mm dia outlet, plain with grating including jointing with solvent cement complete all specified and directed. 118 S&F for PVC waste pipe for urinal/WHB with fitting etc 50 mm dia. 60mm long complete all specified and directed. 119 S & FPVC( SWR ) pipes 110mm dia single socketed , in any lengthwith rubber ring joints as rainwater,(eves gutter fitted in roof forcollecting of rain water).stack clamps out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stays to wall or roof ,welding etc complete all as specified and directed. 120 Dismantling of old ceilling boarding, wooden sacntling any description fixed in any position with nails complete all as specified and directed 121 Dismantling of Eves gutters , wooden sacntling any description fixed in any position with nails complete all as specified and directed. 122 Providing and fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum ) False ceiling tiles of size 595 x 595 mm of approved texture, design and patterns having moisture contents less than 2% humidity resistance of 99% NRCO.50 to .75 as pe IS8225:1987, Noncombustible as per BS 476 (Part 4)-1970 and light reflectance of 85% (Minimum) to be laid in true horizontal level suspended on interlocking metal T Grid of hot dipped galvanized iron section of 0.33 mm thick ( galvanised @ 120 gms per sqm including both sides ) comprising of main T runners of size 15 x 32 mm of length 3000mm, cross -T of size 15 x 32 mm of length 600mm to form grid module of size 600 x 600mm, suspened from ceiling using galvaized mild steel items ( galvanizing @ 80 grams per sqm) i..e 50mm long, 8mm outer diameter M-6 dash fastener 6mm dia fully threaded hanger rod upto 1000mm length and L-swhape level adjuster of size 85x25 x 2mm galvanised iron permieter wall angle of size 24 x 24 x 0.40mm of length 3000mm to be fixed on periphery wall/ partition with the help of plastic rawl plugs at 450 mm ceneter to centre and 50mm long dry wall wood screws. The kwork shall be carried out as per specifications, drawing and as per directions complete all as specified and directed. 123 Dismantling of AC sheets / Galvolume sheet / GI Sheet of corrugated or semicorrugated etc. sheets in roof coverings complete all as specified and directed. 124 Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. 125 M&L for MS framed structure roof trusses (framed), trussed, purlins, crane gantriesand fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats of Grade Fe 410 -W (Gde- E- 250) quality- A etc. complete all as specified and directed. 126 S&F Pre-painted galvalume aluminium zinc coating GI based profilesteel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa, hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) as in roof covering/ cladding to wall,including flashings , ridges, valley etc fixed with self tapping screws as specified 127 S&F Pre-painted galvalume aluminium zinc coating GI based plainsteel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa, hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. 128 S & F for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc. complete, drilled for fixing of steel sheeting or other covering doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, Fe 410-W (Gde-E-165) quality-A, etc complete all as specified and directed. 129 S & F Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, Thickness of sheet 1.60 mm, etc complete all as specified and directed. 130 M & L for preparation of newlyuntreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. 131 Material and labour Preparation new paintedwooden surfaces of any description over 10 cms width or girth not otherwise described and applying two coat of synthetic enamel paint complete all as specified and directed. 132 M&L for complete removal of existing treatment and preparation of old surfaces and applying two coat Acrylic emulsiondisptember with roller over applying minimum 1mm thick white wall care putty over prepared surface to achieve the surface even and smooth for painting complete all as specified and directed (Note:-Contractor shall furnish gaurantee of four year against service rendered) Note:- primer and emulsion paint shall be carred out through air less spray machine (Mechanical means) 133 M&L for preparation of newly plastered surfaces and applying two coat Acrylic emulsiondistember with roller over applying minimum 1mm thick white wall care putty over prepared surface to achieve the surface even and smooth for painting complete all as specified and directed (Note:-Contractor shall furnish gaurantee of four year against service rendered) Note:- primer and emulsion paint shall be carred out through air less spray machine (Mechanical means) 134 M&L for complete removal of existing treament and preparation of wall, washing, scrubbing down and stopping old treatment and painted surface of plastered / decorated surface and applyingtwo coat of Premium Acrylic smooth exterior paint and including priming coat of exterior primer and incl one coat of wall putty complete all a specified and as directed.(Note : painting will be done by brush / spray / roller of building upto the height) all as per directed by Engr -in-Charge) (Note :Rate shall be included for necessary scaffolding and safety measures where required at site ) 135 M&L for new/Old plastered / decorated surface and applyingtwo coat of Premium Acrylic smooth exterior paint and including priming coat of exterior primer and incl one coat of wall putty complete all a specified and as directed.(Note : painting will be done by brush / spray / roller of building upto the heightall as per directed by Engr -in-Charge) Note :Rate shall be included for necessary scaffolding and safety measures where required at site ) 136 M&L for HDPE Double Wall Corrugated pipe 150 mm internal bore laid in trenches & jointed as specified, and including demolition and breaking up drain pipes, complete all as specified and directed. 137 M&L for concrete bed to drain pipes 100mm dia bore using plain cement concrete (1:3:6) type C2(using 40mm graded stone aggregate) including packing under and haunching against the sides of pipes after they are laid and tested in complete all as specified and directed. 138 Taking down copper /aluminium point wiring (light, fan, bell,socketor power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc.Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces ofwalls, floors etc complete all as specified and directed. 139 Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface all as specified and directed at site. 140 Taking down carefully copper/aluminium Sub main wiring of any size fromsurface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. 141 Taking down existing geyser of any capacity after disconnecting all necessary electrical and water supply connections and deposit to MES store yard of AGE E/M No II complete all as specified and as directed. 142 Taking down existing single phase electric energy meter of any capacity after disconnecting all necessary electrical connections and deposit to MES store yard of AGE E/M No II complete all as specified and as directed. 143 M&L point wiring with 1.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC conduit (medium grade) concealed in wall / ceilingwith and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, conceiled on walls and fixed by neans of brass screws incl modular cover plates and cover frme any size/module,for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for the following complete for One light / fan /bell controlled by one, one way switch 5/6 Amps all as specified and as directed . 144 Description all as per ser item No. 143.00 above ,but for one 3 pin, 5/6 amps socket outlet point on independent boardcontrolled by one, one way 5/6 amps switch complete all as specified and directed. 145 Description all as per ser item No. 143.00 above , but for one 3 pin, 5/6 amps socket outlet point on same boardcontrolled by one, one way 5/6 amps switch complete all as specified and directed. 146 M&L point wiring with 2.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC conduit (medium grade) concealed in wall / ceilingwith and including 2.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, conceiled on walls and fixed by neans of brass screws incl modular cover plates and cover frme any size/module,for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one 15A socket point independentcompleteincl taking down of old unsv point wiringall as specified and directed. 147 S&F in replacement of Ceiling rosethree terminals surface bakelite type, AC, 50 HZ, 230V complete all as specified and directed. 148 S & F modular switch1 way 6 A , 1 modulecomplete all as specified and directed. 149 S & Fmodular socket 6 Amps 2/3 pin combined2 module complete all as specified and directed. 150 S & Fswitch modular type 16 A, 1 module complete all as specified and directed. 151 S & F socketmodular type multipurposes 6/16 A, 2 module complete all as specified and directed. 152 S & Fmodular bell push type 6 A ,1 module complete all as specified and directed. 153 S & Fbell multi music type AC 230 volts single pole complete all as specified and directed. 154 S&F surface /wall mounted LED batten fiitng slim channel type poly carbonate bodyT-8 tube light luminare with system efficiency 120 lumens per watts. High quality polycarbonate end cap in white finish and snap fitted to the housing completeall as specified and directed.integrated electronic driver complete with all connectedaccessories all as specified and directed. 155 M&L for Modular angular holder with LED Bulb 9 watts complete all as specified and as directed complete all as specified and directed. 156 S & FLED bldg security light fitting30wattmade up of pressure die cast aluminium housing with acylic cover as diffuser with IP-66 protection complete incl mounting pipe made of GI tubing 40 mm size 1M length bend into size with mounting brackets nut bolt and washers all as specified and directed. 157 S&F MCB DB SPN 8 way ,IP-43, IK 09, double door type with metal doorwith 200 Amps rated bus bar ,230 volts, 50 Hz complete all as specifed and directed. 158 Supply & FixMCB SPN 32 Amps current rating C series 10 KA breaking capacitycomplete all as specified and directed. 159 Supply & FixMCB SP 6 to 32 Amps current rating C series 10 KA breaking capacitycomplete all as specified and directed. 160 Supply and fixing TV socket outlet complete all as specified and as directed. 161 M & L sub main wiring with 2 runs of 06 sqmm main wire along with 1 run of 6 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC concealed / surface conduit (medium grade) wherever necessary with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good disturbed surfaces complete all as specified and directed.Note:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length. 162 Taking down existingexhaust fan/ceiling fan of any sweep after disconnecting necessary connection from ceiling rose to fan and deposit to MES store yardcomplete all as specified and as directed 163 S & Fexhaustfannon metalic single phase 230 volt of size 250 mmsweep with louverincl necessary altrationall as specified and as directed 164 S & Fexhaustfanmetalic single phase 230 volt of size 380 mmsweep with louverincl necessary altrationall as specified and as directed 165 S & F for ceiling fan, 230 Volts, 50Hz, 1200 mm sweep with down road, canopy, blades, BLDC motor etc and service value of the fan shall be greater than 6.1 as per BIS with necessary accessories and electrical connections from ceiling rose to fan teriminal includingwritting the MES Number with synthetic enamel paintcomplete all as specified and as directed. 166 Supply , fixingrigid non metallic PVC conduit fixed conceiled/on wall wherever necessary with all connectedaccessories20 mm dia forcable TV connectionscomplete all as specified and as directed 167 Supply, installation, commissioning and testing indoor type LT wall mounting Panel Board of minimum size 1.00 m (height) x 1.00 m (breath) x 0.30m (depth) factory made CPRI approved panel, weather, dust & vermin proof indoor, double door, front openable, including four compartment for fixing of 4 Nos single phase meter and MCB and providing glass view for reading of meter and providing rubber/ PVC gasket of suitable size all sides of door, withCopper strip busbar of size 25 x 5 mm wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrographic insulators with nuts & bolts at both ends= 04 Nos. , made out of 2.00 mm thick mild steel CRCA sheet with suitable size angle iron supporting frame including applying two coats of Powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces suitable for 3 phase 4 wire system 415/440 volts grade including complete internal wiring with 2.5 sqmm copper wire and connections of all outgoing / incoming existing cable of any size complete incl galvalume sheetfor protection of LT panel from rain/water all as directed 168 INCOMMING:-(a)MCCBIP 44 and IP 66/67 protection Ics =100% lcu, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 160 Amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links -01 No. (b) Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch – 01 Nos(c) DigitalAmmeter (0- 500)Amps, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch and CTs – 01 Nos(d) LED Neon indicator lamp (RYB) with holder,230/250 volts,AC -01 set (set of three) 169 OUTGOING :-(a) MCB SPN 40 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 04 Nos(b) Fixing only serviceable existing electric meter- 04 Nos 170 Replacement of Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground vertically to a depth not less than 2.25 meters deep below ground levelwith top edge of the plate not less than 1.5 Mtrs below normal ground level connect to galvanised earth lead wire of 4.0 sqmm size by means of bolts, nuts, check nuts and washers of galvanized iron or steel up to 7.5 meter length including connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40 mm thick RCC cover 1:2:4 mix with 6mm dia nominal reinforcement @ 150 mm c/c both ways etc completeall as shown in electrical plate No 5, connected to earthing test point complete including testing on completion all as specified. 171 supply and fix electric water heater storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 ltrs BEE 5 star rated complete with all accessories such as safey valve, thermostat, NRV, connecion pipe etc. 172 Supply only single phase energy meter AC 230 volt, 50 HZ, digital display from 10A to 30A all asspecified and directed by Engr-in-Charge 173 Supply and laying and testing Cable XPLE insulated, screened , PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy duty) 1100 volts grade with stranded aluminium conductor of16 sqmm4 core all as specified and as directed. 174 Excavation in trenches, n. exc. 1.5 m wide and n.exc 1.5 m in depth ;for foundation, etc or for shaft, well, cesspit, manhole, pier holes etc.n. exc. 10 sq m on plan and n. exc. 1.5 m in depth and getting out soft/loose soil all as specified and as directed. 175 M&L fine sand cushioningfor cable protection in layers incl punning all as specified and directed.Note : Punned down thickness shall only be measured. 176 Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm all as specified and as directed. 177 S & F tubes, light grade,galvanised, with all fitting of size 40 mm laid in trenches for cable protection all as specified and directed. 178 Returning, filling in, trenches including spreading, levelling watering and well ramming in layers not exceeding 25 cm Soft / loose soil all as specified and as directed. 179 Removing excavated soil to a distance not exc 50 m and depositing where directed at a level not exc1.5m above the starting point all as specified and as directed. 180 M&L for LED ceiling fitting 33 to 36 watts, 2 ft x 2 ft fittings suitable for aluminium grid ceiling, lumen out put ≥ 122 lumen/ watt,THD < 10% environmental friendly, new generation, aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source,incl inbuilt drivers suitable for Grid ceiling complete with atration of aluminium frame work wherever necessary during installation all as specified and directed.
Contract Date: Feb 20, 2026 Contract Value : 40.41 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Madhya Pradesh View Result →
36.
Defence #9609242 AOC
Tender For Repair, Maintenance And Replacement Of Ht Cables, Gods, Vcbs, Rmus, Transformers And Connected E And M Items At Af Stn Suratgarh; 1 Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of cables, erection of poles,struts, stays etc and getting out all as specified and as directed by Engineer-In-Charge. 2 All as per item No. 1 here-in-before but in PCC/floor/road 3 All as per item No. 1 here-in-before but depth exceeding 1.5 metre and not exceeding 3 metre 4 Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, filling back in trenches after cables have been laid and tested, poles,stays,struts have been erected and tested complete all as specified. 5 Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all asspecified. 6 M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding techniqueand necessary machine or manually without damage nearby electric cable, water pipe line etc including HDPE pipe of 100 mm dia suitable for 0.4 mpa working pressure and sealing the end of pipe complete all as specified and directed. 7 M&L for laying GI Tubing light grade 100 mm dia for cable potection in road/ floor all as specified and directed 8 Supplying and laying ofsize 90 mm dia (OD-90 mm & ID-75 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc direct in ground (90 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 9 Supplying and laying ofsize 120 mm dia (OD-120 mm & ID-103 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (90 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 10 Taking out HT/ LT cable of any size/ description from trenches/ floors/ road/ wall/ pipe/ pole and removing & reusefrom site incl making good the disturbed surfaces to match with existing surface all as directed. 11 Relaying/ Labour only for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to panel board/ VCBat existing places or provided by MES forcarrying to other location, upto 33000/11000 volts grade heavy duty cable with XLPE/PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed of size upto 300 sqmm 3 core obtained from item No.10above with required aluminium cable lugs, heat shrink joints specified and directed.Note:The cableJoints and protection pipe and Earth work (if cable laying new rout)shall be meausred seperatly. 12 Supply, laying in trenches/ with pole, jointing and testing of HT 11 KV rated XLPE insulated, PVC bedded earth system stranded aluminium conductor cable 3 core, 95 Sqmm inclusive all incoming and out-going electric connections, complete all as specified and as directed. 13 All as per item No 12 above but of size 3 core 120 sqmm 14 All as per item No 12 above but of size 3 core 150 sqmm 15 All as per item No 12 above but of size 3 core 300 sqmm 16 S&F in replacement cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed. 17 All as per item No 16 above but joint of size 120 to 185 sqmm 18 All as per item No 16 above bu joint of size 240 to 300 sqmm 19 S&F in replacement cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed. 20 All as per item No 19 above butjoint of size 120 to 185 sqmm 21 All as per item No 19 above butjoint ofsize 240 to 300 sqmm 22 S&F in replacement cable jointing kit for 11 KV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed. 23 All as per item No22 above but straight through joint of size 120 to 185 sqmm 24 All as per item No 22 above but straight through joint ofsize 240 to 300 sqmm 25 S&F in replacement cable end termination, outdoor, heat shrinkable type joint complete with jointing material and accessories suitable for 33 KV, 3 core 300 sqmm, XLPE armoured aluminium conductor cable complete all as specified and directed. 26 All as per item No 25 above but indoor type joint 27 All as per item No 25 above but straight through type joint 28 Supply and fixing cable route indicator for HT UG cable of 11000 Volts bolted with 40x6mm flat iron member of height 0.90m and 80mm dia CI plate, embeded in PCC 1:3:6 type C-2 of size 20cm x20cm x30cm block complete all as specified and as directed by Engineer-in-Charge. 29 Supply and fixing pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 150mm height, 150mm dia for working pressure 11000 Volts grade of HT line including taking down existing cracked/unserviceable pin type insulator complete all as specified and directed. 30 S&F in replacement pin type, porcelain, vitreous, white, brown or green insulator/ polymer including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, for 33KV grade complete incl taking down old/unsv all as specified and directed. 31 Supply and fixing disc type insulators, porcelain vitreous white brown or green, 145mm hight and 255mm dia ball and socket type, single disc assembly for tension with tension clamps for conductor having working pressure 120 KN for11000 Volts /33000 volts (use suitable string ) with highest voltage capacity 12 KV including taking down existing cracked/unserviceable disc type insulator complete all as specified and directed. 32 Taking down old U/S GO switch any type and size from HT 2/4 poles structures. 33 S & FGang operated switch outdoor type 11000 Volts, 200 Amp capacity tripple pole machenically operated suitable for operation from ground level and for vertical mounting complete with HT insulators 9 Nos., channel, knife blades, GI pipe medium grade 25 mm dia for operating mechanism worked from ground level , locking arrangement with handle all as specified. 34 S & FGang operated switch outdoor type 11000 Volts, 400 Amp capacity tripple pole machenically operated suitable for operation from ground level and for vertical mounting complete with HT insulators 12 Nos. with dropout fuse set, channel, knife blades, GI pipe medium grade 40 mm dia for operating mechanism worked from ground level, locking arrangement with handle all as specified. 35 All as per item No 34 but for 33 KV 400 Amp, operating horizontal direction incl taking down old/unsvall as specified and directed 36 S&F in replacement expulsion fuse unit single pole mounted on insulator & steel frame complete with fused barrel (drop out fuse) suitable for 11 KV for current rating upto 20 Amp incl taking down old/unsv fuse unit complete all as specifed and directed. 37 S&F in replacement HT 33 KV outdoor type dropout fuses double stack channel type complete with insulator of rating up to 400 Amps incl taking down old/unsvcomplete all as specified and directed. 38 Repairing / Servicing the Air break isolating switch HT 11 KV 200/400 Amps by replacingthe defective major spares parts including provn of minor bolts nuts etc all as specified and directed.Note: Major spare parts will be measured & paid seperately under relevant items of Sch-A 39 Supply only Male contact/ moving Contact Blade 40 Supply only Female contact/Fix Contact Jaw 41 Supply only Tinned copper Flexible jumper 200A/400 A 42 Supply only MS jumper carrier 43 Supply only Back Connector plate 44 Supply only Petroleum Jelly 45 Dismantling/ Taking down old unserviceable lightning arrestor 11 KV from HT 2/4 poles structures. 46 M&L for HT 11 KV lightening arrestor expulsion type having discharge capacity of 65 KA, suitable for 11 KV HT line includng making connection with existing GI earth wire. 47 S&F of lightning arrestors expulsion type complete with all fittings, suitable for 33 KV grade transmission class, discharge capacity 65KA including brackets, clamps, nuts washers and connecting to 4 mm dia GI earth wire including taking out old unservicable lightining arrester allcomplete all as specified and directed. 48 Supply and fixing of Jumper for HT OH Lines 33/11 KVbus system to GOD and GOD to DO Fuse unit with jumper made of aluminium conductorinsulated with colour coding, (Red Green , Blue) with all conneted item i.e nut bolt, U G clamps etc up to length of size 3 to 5 Mtr all as specified and directed by Engineer -in-charge. 49 Dismantling concrete poles/ struts of any size complete all as specified and directed. 50 Demolition of concrete (coping of PCC/ GI pole/ Road) of any description and in any position 51 Supply and erecting in true vertical position steel tubular swaged pole, 11 metre long, complete with mild steel base plate 6mm thick of size 300mm x 300mm, B-118 finial taper plug, bolts, nuts, washers and screws, type 410 SP-55 including drilling of holes of required size and nuts for fixing of cross arms, painting with two coats of aluminium paint over a coat of red oxideand two coats of black bituminous paint for portion embedded in concrete, painting five black and white bands at lower portion of pole each of 300 mm height at 300mm spacingcomplete all as specified and directed.(Note : Excavation, earth work and PCC in foundation of poles, coping etc shall be measured and paid separately under respective items of Sch A). 52 PCC 1:2:4 (nominal mix) type B-2 using 40mm graded crushed stone aggregate, as in coping of poles and the like complete including weathering, slightly rounded or chamfered angles and throating all as specified and directed. 53 PCC 1:3:6 (nominal mix) type C-2 using 40mm graded crushed stone aggregates, as in foundation filling and mass concrete for poles and stay/installation paths complete all as specified and directed. 54 M&L for PCC 1:2:4 type B1 using 20mm graded aggregate in coping of size (0.65x0.55x0.45) Mtr for PCC/RCC/Steel tubular pole complete with 10mm thick cement plaster CM 1:4 on coping surface complete all as specified and directed. 55 M & L for scrapping of old painted surfaces of electric pole covered by dust and other depositedmaterials by cleaningwith wire cup brush on drill /grinderfromsteel tubular pole of length upto 11 metres including cross arms,bracing, clamps etc and painting with one coat of Epoxy zinc phosphate primer and including two coats of synthetic enamal paint upto 1.50 mtr height having alternative existing strip (white and black or Red and yellow )of 30 cm height each, all as specified & directed by Engineer-in-Charge. 56 M & L for scrapping existing deteriorated complete removal of old paint bywith wire cup brush on drill /grinderfrom the steel tubular 2 pole structure of 9.0-11.0 mtr height above ground levelwithout removing accessories and preparation of surfaces for repainting the poles with and including two coats of synthetic enamal paint upto 1.50 mtr height having alternative existing strip (white and black or Red and yellow )of 30 cm height each, including one coat ofEpoxy zinc phosphate primer to the remaining part of pole (i.e above 1.50 mtr height) and its cross arms, bracing, support and all steel members complete all as specified and directed. 57 All as per Ser item No. 56 above but for 4 pole structure. 58 All as per Ser item No. 56 above but for 6 pole structure. 59 Dismantling ACSR or AAC conductor complete all as specified and directed. 60 Supply andfixing aluminium conductor, steel reinforced (ACSR) of following sizes as in overhead conductor including fixing aluminium tapes for binding complete all as specified and directed: -(a) 6/1 x 3.0- Ferret (b) 6/1 x 2.59- Weasel(c) 6/1 x 2.11- Squirrel Note: The weight of the conductor shall be determined as stipulated in Preamble (b) & (c)on Page 384 of SSR-2010 Part-II (Rates). 61 M& L for Stringing of ACSR conductor any size to HT/LT over heads lines, streching properly to achieve proper sag including binding to insulators using GI/aluminium binding wire all as specified and as directed by Engineer-in-Charge. 62 M& L for Stringing of GI cradle Guaredconductor any size to HT/LT over heads lines, streching properly to achieve proper sag including binding to insulators using GI/aluminium binding wire all as specified and as directed by Engineer-in-Charge. 63 M&L for restraining of GI wire of any size on pole after disconnecting all binding on cross arms and redoing all bindings providing required T&P all as specified and directed 64 Supply and fixing PVC moulded LT Line separator suitable for 4 lines OH system. Make- Denson/Mex-well/JB/Jaipuriya brothers 65 Surface excavation over the areas around the substations not exceeding 45 cm depth and averaging 30 cm deep and getting outspoil inhard & dense soil including levelling the surface. 66 M&L forscreened river sand/ tibba filling on the levelled ground surface/ducts in sub stations/below 2 pole & 4 pole structures etc 67 M&L stone aggregate of size 35 to 40mm spreading over sand layerin the substation areas including proper leveling all as directed and shown at site. 68 M&L stone aggregate of size 20 to 25mm spreading over sand layer in the sub stations areas including proper levelling all as directed . 69 M&L taking out spreadedaggrgate of any size &sieving the aggrgate & dust/ sand & relaying the aggregate after sieving in the sub stations 70 M&L brick work with sub class B brick straight cured on plan exc 6m mean radious built in cm 1:4 71 Rendering/cement plastering 15mm thick on fair faces of brick work or concrete surfaces in Cement mortor 1:4 finished even and smooth without using extra cement 72 S & F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk),forming holes of Fe 410-W (Gde E- 250) quality without any attachmen use for cable duct cover at substncomplete all as directed. 73 M&L for replacement of earth pit chamber of size 300 x300 mm (internal dimensions) and 450x450mm(External)with PCC 1:3:6 type C-1 , RCC 1:2:4 type B-1 reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover 50 mm thick with 12 mm dia MS hook of suitable size and shape for lifting and MS angle iron frame 50 x 50 x 4 mm including GI funnel with wiremesh complete all as specified. 74 Material and labour for fixing of display Board of 60cmx30cm forearth pit made out of 2 mm thick MS sheet welded on angle iron legs 0.75 mtr long (02Nos) of size 40x40x6mm duly embeddedin PCC block 1:2:4, type B-1, using gradedcrushedstone aggregate, of size 23x23x30cm fixed in ground including necessary earthwork. Display Board shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in- Charge. The following is to be written on the board:- (a) Earth Pit No. -(b)Connected To -(c) Checked on -(d) Next due date.-(e) Ohmic Value 75 Cutting and uprooting grass, vegetation shrubs, bushwood undergrowth, roots and trees not exceeding 30 cm girth (measure one metre above ground level) in and around electrical sub stations, two/four pole structures and removing rubbish to a distance upto 50 metres outside the periphery of the area, complete all as specified and as directed by Engr-in-Charge. 76 Supply and fixing of synthetic insulating matsuitable for 11 KV installation of size 1.00 m x 2.00 m and 25mm thick (ISI marked) complete all as specified and directed. 77 Supply and fixingEarthing dischard rod(ISI Marked), extendable upto 18 feet height with rubber hand grip and suitable size copper wire suitable for working with 11 KV HT lines complete all as specified and directed. Make: Jaipuria/Rashtriya Electricals 78 Supply and fixAluminium thimble/lugs suitable for 50 sqmm to 95 sqmm XLPE cable all as specified and directed. 79 Supply and FixAluminium thimble/lugs suitable for 120 sqmm to 185 sqmm XLPE cable all as specified and directed. 80 Labour for disconnecting LT/HT cable of any size from structure/pole/transformer for finding fault, M&L for defect rectification LT/HT cable laid in trenches or any location by liacting fault with the help of electronic fault machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. The entire repair work to be completed with in 12 hours of instruction from Engr-in-charge as specified. Note:- Complaint will be notified to contractor on mobile phone at any time between 0800 to 2200 Hrs and has to be rectified with in 12 hours after notification, failing to which Rs500/- per day complaint will be recoverd. fault locating with electronic fault locator, excavation and earth work, disconnecting and reconnecting both end of cable, relaying of sand and protective cable covers are deemed to be included in the quioted rate all as specified and directed by Engineer-in-charge.Note: joint kit will be measured seperately in appropriate item in this schedule 81 Labour only for disconnecting LT/HT cable of any size from pole (height 7.5 to 9 mtr) /transformer/panel and re-connecting ofcable at both endafter removing carbon /burnt insulation part of cable by cutting refixing cable withnew cable lugs . The entire repair work to be completed with in 06 hours of instruction from Engr-in-charge all as specified. Note:- Complaint will be notified to contractor on mobile phone at any time between 0800 to 2200 Hrs and has to be rectified with in 06 hours after notification, failing to which Rs 500/- per daywill be recoverd per complaint. 82 M&L for earthing complete with GI earth plate 600x600x6mm thick electrode and 32x6 mm GI strip as earthing lead buried directly in ground (Earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground connected to GI strip earth lead by means of bolts, nuts, check , nuts and washers of galvanised iron or steel all as shown on electrical plate no. 3 including 40 mm dia medium grade GI protection pipe, 20mm dia GI medium grade watering pipe, funnel, wire mesh , charcoal dust, PCC pit and 50mm thick RCC cover, earth work in any type of soil connected to earthing test point complete all as specified and as directed.Note: GI stripbeyond 7.5Mtr length from earth electrode shall be measured and paid separately). 83 All as per item No 82 above but with 4 mm dia GI wire as earthing lead andGI protection pipe 20mm dia medium grade. 84 M&L for earthing complete with copper earth plate 600x600x3.15mm thick electrode and 20x3 mm copper strip as earthing lead buried directly in ground (Earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground connected to copper strip earth lead by means of bolts, nuts, check , nuts and washers of copper all as shown on electrical plate no. 3 including 40 mm dia medium grade GI protection pipe, 20mm dia GI medium grade watering pipe, funnel, wire mesh , charcoal dust, PCC pit and 50mm thick RCC cover, earth work in any type of soil connected to earthing test point complete all as specified and as directed.Note : Copper strip & GI pipe 40mm dia beyond 7.5mtr length from earth plate shall be measured & paid separately under respective item) 85 S&F earthing strip 32x6mm GI fixed to wall/pole/buried in ground /drawn in pipe complete. 86 S&F earthing strip 20x3.0 mm copperfixed to wall/pole/buried in ground /drawn in pipe complete. 87 S&F GI wire 4mm dia iron fixed to wall/pole/buried in ground /drawn in pipe complete. 88 S & F Danger notice plate for HT poles size 1.6 mm thick mild steel sheet vitreous enemelled white letter figures and converntionl skull and bones maked in red colour with MS clamp of flate iron 25X3mm size, bolts, nuts, size of plate 25 X20 Cm complete all as directed by Engineer-In-Charge. 89 Dismantling unserviceable any size of cross arms from pole /structures/anti-climbing device etc complete allas specified and directed. 90 M&L for MS work confirming to Fe-410-O or Fe-310-O as in cross arms, support, bracings, stiffeners, clamps channels fabricated from structural steel including nuts, bolts and washers welding, bending cold or hot drilling holes for bolts in any shape or size all as directed including two coats of aluminium paint over a coating of red oxide primer all as directed by Engineer-In-Charge. 91 M&L for anti climbing devices, spike type fabricated out of MS bars (Round, square and flat) including nuts, bolt, washers and welding in two halves made to shape to suit the cross section of the pole including painting etc complete all as specified and as directed. 92 Cutting/trimming of tree branches under OH LT/HT electric line including cleaning upto 3.00 mtr horizontal distance on both sides of OH electric line from ground level of the poles including removing all creepers smal bushes etc of under OH line upto 60 mitre each span complete all as specified and directed.Note: Materials/T&P like Axies, Daw, rope and the like will be provided by the contractor without any extra cost to the Govt. 93 M&L for stay assembly complete with MS stayplate 300x300x6mm thick galvanized stay rodnot less than 20mm dia, 2.15 M long galvanized stay bow, galvanized thimble,stay clamp etc. all as shown in electrical plate No1of SSR part-I.Note:- Excavation,earthwork,cement concrete loop type insulators and stay wire shall be measured and paid separately under relevant items. 94 M&L for Galvanised stay strand, size 7/4mmcomplete. 95 M&L for loop insulator, vitreous, porcelain, white, brown or green, large size with overall dimensions 50x140mm clearance of hole 25.5 mm complete. 96 Overhauling/ servicing /calibration of HT VCB 400/630 Amps 33 KV of any make by carrying out following job:-(i) Taking out VCB trolly from the panel board.(ii) Removal of dirt,dust & carbon particles by air blower(iii) Cleaning of all moving & fixed contacts of VCB with dry cloth & CRC solution and greasing of moving contacts & gears.(iv) Checking and setting of VCB ON/OFF operation mechanism through TNC & push button and triping relay and adjust the trip setting.(v)Checking tightness of all control wires.(vi) Checking leakage in vacuum interrupter by Hi-Pot test.(vii) Assembly of trolly and testing complete.(viii) Servicing shall be got carried out by authoised rep of the VCB manufacturer and the service engineer submit a service report of each VCB with detais of settings perameter.Note: Spare parts shall be undertaken through authorised service centre of OEM as directed by the Engineer-in-charge. 97 Overhauling/ servicing /calibration of HT VCB 400/800 Amps 11 KV of any make by carrying out following job:-(i) Taking out VCB trolly from the panel board.(ii) Removal of dirt,dust & carbon particles by air blower(iii) Cleaning of all moving & fixed contacts of VCB with dry cloth & CRC solution and greasing of moving contacts & gears.(iv) Checking and setting of VCB ON/OFF operation mechanism through TNC & push button and triping relay and adjust the trip setting.(v) Checking tightness of all control wires.(vi) Checking leakage in vacuum interrupter by Hi-Pot test.(vii) Assembly of trolly and testing complete.(viii) Servicing shall be got carried out by authoised rep of the VCB manufacturer and the service engineer submit a service report of each VCB with detais of settings perameter.Note: Spare partsshall be undertaken through authorised service centre of OEM as directed by the Engineer-in-charge. 98 Supply and fixing in replacement microprocess numerical relay for 33/11 KV VCB tripping system ( 03 Over Current/02 O/C , 01 Earth Fault and high set instantaneous protection in single unit) suitable for opration on 24V DC-110V DCall as per Model No CGI14N/CGI4C of Make: Crompton Greaves or equivalent in AREVA(Note:ifExisting relays are of Electromagnetic type, hence any modification in the wiring,and panel sheet enclosure is deemed to be inclusive in the scope of work). 99 Supply and fixing in replacement Ammeter for HT panel Square dial of size 100 mm digital type complete all as specified and as directed.Make : AE/Rishabh (Note: Existing meter analough type and large in size, hence any modification in the wiring,and panel sheet enclosure is deemed to be inclusive in the scope of work). 100 Supply and fixing in replacement voltmeter for HT panel Square dial of size 100 mm digital type complete all as specified and as directed.Make : AE/Rishabh(Note: Existing meter analough type and large in size, hence any modification in the wiring,and panel sheet enclosure is deemed to be inclusive in the scope of work). 101 M & L for Vaccum Interrupter type WL-33379 or as per exixtingsuitable for 11 KV VCB Panelcomplete all as specefied and directed. 102 M & L for Isolating contact assembly 400/800 Amps with complete set of contact (set of six) suitable for 11 KV VCB Panelcomplete all as specefied and directed. 103 Supply and fixing in replacement indicator lamp assembly 24V DC in (Red,Yellow, White, Green & Blue colour) for HT panels complete all as specified and as directed. 104 Supply install, testing and commissioning in replacementof Power packunit input voltage 90-270 Volts and out put voltage 24 Volts DC having4-digit degital Volt & Ammeter, High resolution D/A, A/D converter , Digital interface as standard function etc. including taking out US battery bank unitcomplete all as specified and as directed 105 Supply install, testing and commissioning in replacement of Power packunit input voltage 110 Voltage and out put voltage 24 Volt DC having4-digit degital Volt & Ammeter, High resolution D/A, A/D converter , Digital interface as standard function etc. including taking out US battery bank unit complete all as specified and as directed 106 Supply and fix Motor cut off switch complete all as specified and directed 107 Supply and fix ZZ Switch complete all as specified and directed 108 Supply and fix HRC Kit kat fuse 2A, 4A,6A ,10A & 20 A complete all as specified and directed 109 Supply and fix Closing coil 24V DC complete all as specified and directed. 110 Supply and fix Tripping coil 24V DC complete all as specified and directed 111 Supply and fix of Multifunction meter (V,A,P,PF) for 11 KV VCB as per existing sample complete all as specified and directed. 112 Supply and fix of Big gear and small gear set complete all as specified and directed. 113 Supply and fix of TNC switch 11 KV/33 KVpanel complete all as specified and directed. 114 Supply and fix Segment gear complete all as specified and directed. 115 Supply and fix of 11 KV Spring charging motor 220V AC/DC complete all as specified and directed. 116 Supply and fix Motor & Gear assembly 110V DC and 220 ACfor 11 KV VCB Panelcomplete all as specefied and directed. 117 M&L for painting to VCB,Fire stand post ,duct plate etc atinstallations with two coats of synthetic enamel paint after making the suface free from oil/grease/rust and applying a coat of red oxide primer complete including writing details as per directed like as SM Nos/feeder detail etc. all as specified and as directed. 118 S & F in repair Aux relay Buch/WTI/OTIfor 11 KV VCB panel ,Auxiliary supply 24Volt DC as per existing complete all as specified and directed. 119 S & F Cast resin type 11KV VCB three phase current transformer having ratio 100+50/5+5Aas per IS: 2705 having protection core class 5P10, burden of 15VA and metering core class CL1.0 and burden of 15VA, breaking capacity of 13.1 KV for 1.0 second 120 S & f 11KV VCB three phase indoor oil cooled PT of ratio 11KV/RT 3/10V/RT 3/110/RT 3 class 0.5-3, burden 100VA, insulation level 35/75 KV, voltage factor 1.2 cont and 1.9 for 30 sec, conforming to IS-3156 121 S&F in replacement HT fuse wire upto 60 amp asper site requirement mounting on insulator of 2 Pole/4 Pole structure complete with fused barrelfor 11 KV complete all as specifed and directed. 122 Disconnecting, opening of HT Capacitor bank of any description and any make of rating 11 KV indoor capacitor switching APFC paneland outdoor capacitor bank type with automatic/manual control having output 2400 KVAR (Step rating proposed : 400 KVAR x 2+800 KVAR x 2 desired 0.99) for servicing / overhauling, taking out and removing unserviceable / defective parts including cleaning & servicing, greasing, oiling of the parts etcand replacement of unserviceable parts with new one, reassembling the HT Capacitor Bankafter overhauling/ servicing and its testing complete all a specified and directed. Note:Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch A as supply only 123 Spply only HT HRC Fuses suitable for 11 KV, 400 KVAR complete all as specified and directed. 124 Spply onlyHT HRC Fuses suitable for 11 KV, 800 KVAR complete all as specified and directed. 125 Spply only NDVR Relay suitable for 400 KVAR step complete all as specified and directed. 126 Spply only Contactor coil 127 Spply only Copper bus bar 50x10 mm length 1 mtras per site requirement 128 Dismantling and taking down by removing HT and LT connection of indoor /outdoor type 11/0.433 KV transformer of capacity up to 200 KVA from existng platform/4 Pole/inside sub station Lowering the same carefully and shifting to other location within Air force station(both tech & resdential) as directed by Engineer-in-charge with and including re-installation by means of arrangement and testing and including additional/alterationfoundation according manufactures complete all as specified and directed . Note : (a) Installation of transformer , testing and connecting the both HT/LT cables , commissioning of transformer after checking voltage and loading at full load shall deemed to be included in quoted rates .(b) Contractor shall provide necessary tripod, chain & pulley, T&P, etc for transportation, the rent and foundation for additional/alteration shall deemed to be included in the quoted rate. 129 All as per srl item No128, abovebut capacity of transformer more than200 KVA andupto 500KVA complete all as specified and directed . 130 Repair to distribution transformer step down 11/0.433 KV indoor/outdoor type of capacity 100 KVA to 250 KVA, after dismantling the transformer carefully, opening the top cover of transformer for inspection /repair, draining out the transformer oilfrom the housing complete, taking out the core and winding by disconnecting the internal connections, removing the carbon/sludge deposit in transformer housing core, replacement of unserviceable rubber bushes and washers, replacement of tap changer winding and thimbles, replacement of silica gel, replacement of top cover gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable LT & HT bushes, cutting the burnt out winding and re-winding the same with suitable size of super enamelled copper/aluminium wire as per existing guage, insulating the winding connection by using fire proof sleeve and fire proof tape, varnishing the coil, keeping the coils in electric oven chamber for 24 hrs to remove the moisture, painting of complete transformer body from outside and inside, marking of MES/SM Number etc, replacement of conservator tank glass, re-installing the core and winding inside properly, making the all connection with suitable copper lugs, filling of new transformer oil, reinstalling the top cover after cleaning and painting of housing, conservator tank, expulsion vent etc, Meggering the LT and HT side of the Transformer and testing complete all as specified and directed by Engineer-in-Charge. Note :- (i) Winding wire for making of coils, HT/LT bushes, new transformer oilwill be measured & paid seperately(ii) Contractor is required to submit test report for repaired transformer duly signed by Engineer-in-Charge before installation. 131 All as per Srl item No 130 above but of capacity 11 / 0.433 KV, above 250 KVA upto 630 KVA complete all as directed. 132 S & F in replacement brass terminal rod with nuts , boltswasher and bushing suitable for HT and LT side of the transformer of any make and capacity upto 200 KVA complete all as specified and directed . 133 All as per srl item No132, abovebut capacity of transformer more than200 KVA andupto 630KVA complete all as specified and directed . 134 S & F in replacement tap changing switch suitable for operation on 11/0.433 KV distribution transformer with tappings on 2.5% , 5% and 7.5% on requirement basis for upto 630 KVA capacity transformer complete all as specified and directed . 135 Supply and Filling in replacement superior quality silica jel inside the breather assembly and fixing properly with transformer complete all as specified & directed. 136 S & F in replacementoil valve for drain out/filling in screwed both ends with iron wheel head suitable for transformers up to 200 KVA capacity complete all as specified anddirected. 137 All as per srl item No 136, abovebut capacity more than 200 KVA andupto 630 KVA complete all as specified and directed . 138 M & L for fabrication HT / LT side box covers made of bakelite sheet10 mm thickness with proper nuts bolts incl cutting sheet to required size , drilling holes for nuts/bolts etc complete allas specified and directed. 139 S & F in replacement oil temperature gauge 0 -120 degree analogue dial type for transformer complete all as specified & directed 140 M & L for filteration and dehydration of transformer oil by dehydration machine to achieve the die-electric strength/ insulation value upto65 KV/40KV (RMS) atstandardgap of electrodes 2.5 mm for one minute in 33 KV/11 KV transformer capacity 3 MVA TO 5 MVA including insulation testing of oil with help of suitable equipments before and after dehydration including BDV Test compete all as specified and directed.Note:(i) Contractorwill have to arrange the dehydration machine and transformer oil dielectric strength testing equipmentas mentioned and same shall be deemed to be included in the item rate quoted.(ii) Test result of transformer oil before and after dehydartion is required to submit by contractor duly signed by all concerned. (iii) The contractor shall ensure that the conservator tanks are full to its level before commencement of dehydration process. (iv) Additional quantity of transformer oil if any required for making the oil level upto the requirement in transformer shall be measured and paid separately as supply and filling but its cost of heating shall be deemed to be included in the rate quoted for above item. 141 Supply and filling transformer power oil meeting IEC 60296-2003-11, 3rd edition standard specification and ASTMD 1275B test requirements for corrosive sulpher of BDV not be less than 70 KV at 2.5mm gap for reduced level of transformer due to evaporation/ leakage/losses due to dehydration in HT33 KV transformer/HT 11 KV AVR transformer/11 KV distribution transformer all as as specified and directed. 142 Supply only super enameled copper conductor wire of suitable gauge and size as per requirement for rewinding of 33/11/0.433 KV power/distribution transformer complete all as specified and directed . 143 Supply only super enamelled aluminium conductor wire of suitable gauge and size as per requirement for rewinding of 11/0.433 KV distribution transformer complete all as directed. 144 Supplying and fixing in replacement, Porcelain Transformer bushing on LT (440 Volt) side, including brass stems conical bush and gasketafter disconnecting electrically and mechanically for indoor/outdoor transformer of capacity upto 160 KVA andre-connecting electrically and mechanically, testingcomplete all as specified and directed. Note.The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transforer oil,opening of top cover by unscrewing nut, bolts washers andsuitable size pad type bus bar almuminium and nut bolt washers. 145 All as per Serial item No144 here-in-before butcapacity 200 KVA to 315 KVA 146 All as per Serial item No 144 here-in-before but capacity 400 KVA to 630 KVA 147 Supplying and fixing in replacement, Porcelain Transformer bushing on HT (11 KV) side, including brass stems conical bush and gasketafter disconnecting electrically and mechanically for indoor/outdoor transformer of capacity upto 160 KVA andconnecting electrically and mechanically, testingcomplete all as specified and directed. Note.The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transforer oil,opening of top cover by unscrewing nut, bolts washers andsuitable size pad type bus bar almuminium and nut bolt washers and reconnection 148 All as per Serial item No 147 here-in-before but200 KVA to 315 KVA 149 All as per Serial item No 147 here-in-before but 400 KVA to 630 KVA 150 Supplying and fixing in replacement,all unserviceable gasketafter disconnecting electrically and mechanically for indoor/outdoor transformer of capacity upto 200 KVA andre-connecting electrically and mechanically, testingcomplete all as specified and directed. Note.(i) The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transforer oil,opening of top cover by unscrewing nut, bolts washersetc. (ii)Joint shall be leak proof and any leakage noticed after repair work shall be rectified by the contractor without any extra cost to the deptt. 151 All as per Serial item No 150 here-in-before butmore than 200 KVAand up to 630 KVA 152 S & F in replacement, Silica Gel Breather assembly including vent pipe and Silica Gel for indoor/outdoor transformers,capacityupto 200 KVA complete all as specified and directed. 153 All as per Serial item No152 here-in-before butcapacity more than 200 KVA and upto 630 KVA 154 Supply and fixing in replacement 3mm thick Sheet glass (each not exceeding 0.9 Sqm) ordinary quality and glazing with oil putty on cabin of OTI and WTI gauge of transformer upto capacity 630 KVA complete all as specified and directed. 155 Supply and fixing in replacement thermometer of transformer upto capacity 630 KVA complete all as specified and directed. 156 M & L for cleaning and preparation of steel surfaces of existing dull painting of transformer outdoor type including radiators, cooling ducts, vent pipes, condensor etc and applying two coats of synthetic enameled paint (heat resistant type)according to to IS colour code by spray machine including writing MES /SM No. in capital letters of suitable size on body for capacity upto 160KVA transformer outdoor/indoor complete all as specified and directed 157 All as per item No: 156 but capacity above 200 KVA and upto 630 KVA. 158 Repair to distribution Power transformer 33/11 KV outdoor type of capacity 3 MVA to 5 MVA , after dismantling the transformer carefully, opening the top cover of transformer for inspection /repair, draining out the transformer oilfrom the housing complete,replacement of unserviceable rubber bushes and washers, replacement of tap changer winding and thimbles, replacement of silica gel, replacement of all gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable HT bushes, painting of complete transformer body from outside and inside, marking of MES/SM Number etc, replacement of conservator tank glass, filling of new transformer oil, reinstalling the top cover after cleaning and painting of housing, conservator tank, expulsion vent etc, Meggering the Transformer and TTRtesting with complete all as specified and directed by Engineer-in-Charge. Note :- Transformer oil /Winding wirewill be measured & paid seperately(ii) Contractor is required to submit test report for repaired transformer duly signed by Engineer-in-Charge before installation. 159 Supply and fix inreplacement WTIrelay suitable for 3.15 MVA /5 MVA transformer control panel completeall as specified and directed by Engr-in-charge. 160 Supply and fix inreplacement OTI relay suitable for 3.15 MVA/ 5 MVA transformer control panel complete incl taking down unsv all as specified and directed by Engr-in-charge. 161 Supply and fixinreplacement Mastertripping relay with display suitable for 3.15 MVA/5 MVA transformer control panel complete incl taking down unsvall as specified and directed by Engr-in-charge. 162 Supply and fixinreplacement Differntial protectionrelay with display suitable for 3.15 MVA/5 MVA transformer control panel complete incl taking down unsvall as specified and directed by Engr-in-charge. 163 Supply, fixing and testingin replacement Buchholz relay with display suitable for 3.15 MVA/5 MVA transformer control panel complete incl taking down unsvall as specified and directed by Engr-in-charge. 164 Supply and fix inreplacement Over/Under voltage protectionrelay with display suitable for 3.15 MVA/5 MVA transformer/ 33 KV VCBcontrol panel complete with testing and calibrationincl taking down unsvall as specified and directed by Engr-in-charge. 165 Supply & Fixmarshaling box complete with all sensor/Meter/indicatorfor protection of winding temprature , oil temprature etc suitable for 5 MVA/3MVA Transformeror as per existing incl connection andtaking down unsv all as specified and directed. 166 M&L for overhauling of the 11 kV Automatic Voltage Regulator (AVR) involves a comprehensive inspection, cleaning, testing and restoration process to ensure reliable performance and accurate voltage regulation. The scope includes the following :-(a) Initial Inspection: Visual and mechanical inspection of the AVR and associated components to assess overall condition and identify faults or degradation.(b) Dismantling: Safe removal and disassembly of the AVR unit including checking connections, terminals and internal assemblies.(c) Cleaning: Removal of dust, oil, moisture, and other contaminants using appropriate cleaning agents and techniques.(d) Component Testing: Electrical testing of control circuits, sensing mechanisms and regulating components to detect wear, drift or failure.(e) Replacement of minorParts: Replacement of defective or worn-out components such as resistors, capacitors, relays, or control cards with compatible, high-quality spares. 167 (f) Reassembly and Calibration: Reassembling the AVR and performing calibration to manufacturer specifications for optimal voltage regulation performance.(g) Final Testing: Functional testing under simulated or actual load conditions to verify stability, response time and output regulation.(h) Reporting: Preparation of a detailed service report including findings, actions taken, test results and recommendations.Note :- (i) Restore the AVR to its original working condition with improve efficeincy andreliable operation of the 11 KV system.(ii) The above work shall be carried out by the authorised manufacturer and rate for the same are included in this item. Nothing shall be paid extra on this account. Note :- Following Major spare parts will be measured & paid seperately 168 Supply only AVR Carbon roller assemblycomplete all as specified and directed 169 Supply only tag and tail assey AVRcomplete all as specified and directed 170 Supply only B4c limitt switchcomplete all as specified and directed 171 Supply only PCB sensing relaycomplete all as specified and directed 172 Supply only Motor 40 KG with Gearcomplete all as specified and directed 173 Supply only Delta change flip flopcomplete all as specified and directed 174 Supply only TDR 240 V AC complete all as specified and directed 175 Supply only Aux Contactorcomplete all as specified and directed 176 Supply, installation, testing and commissioning of 11 kV, 630 Amp, 3 Pole, Outdoor Type Load Break Switch (LBS) with manually operated gang mechanism, suitable for breaking load current under normal service conditions, complete with insulators, arcing horns, operating mechanism, earth blades, padlocking arrangement and all other necessary accessories for safe and efficient operation ,The LBS shall be mounted on hot dip galvanized steel support structure duly fabricated with base frame, operating pipe, crank and handle, including providing and casting of cement concrete foundation in 1:3:6 type C-2 (using 40 mm graded stone aggregate) with necessary excavation, formwork, curing and finishing smooth, including grouting of bolts and painting of steel structure with two coats of aluminium paint over one coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge.
Contract Date: Feb 16, 2026 Contract Value : 31.31 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
37.
Rural Development #9577286 AOC
Gpm_E-Tender_2022-23_05 To Purchase Of Electrical Material For Year 2022-23 At Grampanchayat Manjari Khurd Tal Haveli Dist Pune , Electrical Material , 9 Amp Mcb , Spmcb 6A To 32A, B- Series ( For Lighting ) , Dpmcb 6 A To 32 A Bseries ( For Lighting ) , Tpmcb 6 A To 32Amp , Dpmcb 40A To 63A B- Series ( For Lighting ) , Tpmcb 40A To 63A , Two Pole Power Contactor 250V 32A For Time Switch Complete , Dp Switch Isi Mark , Pvc Insulated Pvc Round Sheathed 1.5 Sq.Mm ( 30 No. X 0.25 Mm Dia. ) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv , Pvc Insulated Pvc Round Sheathed 2.5 Sq.Mm ( 50 No. X 0.25 Mm Dia. ) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv , Led Street Light Fitting Suitable For 26W To 36W Led Street Light, Including Lamp, With Pf > 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Alluminium Alloy And Heat Sink Bajaj Make , Led Street Light Fitting Suitable For Above 40W To 50W Lamp, Including Lamp, With Pf > 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per , Led Street Light Fitting Suitable For 60W Lamp, Including Lamp, With Pf > 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete , Led Street Light Fitting Suitable For Above 70W- 75 Lamp, Including Lamp, With Pf > 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete , Led Street Light Fitting Suitable For 90 W Led Street Light, Including Lamp, With Pf > 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Alluminium Alloy And Heat Sink , Led Street Light Fitting 100W, Including Lamp, With Pf > 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Odf / Fls-2. , Led Street Light Fitting 120 W, Including Lamp, With Pf > 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Odf / Fls-2. , Led Street Light Fitting 150 W, Including Lamp, With Pf > 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete , Led Flood Light Fitting Of 120W, Including Lamp, With Pf > 0.95, Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete , Led Flood Light Fitting Of 150W, Including Lamp, With Pf > 0.95, Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete , Street Light Bracket Made From 40 Mm. Dia ‘B’ Class G.I. Pipe, 0.6M. In Length Along With Pole Cap Of 300 Mm Length And 80 Mm Dia Duly Welded With Provided Leads , Single Arm Bracket , Double Arm Bracket , G.I Wire ( 06 Guage ) , G.I Wire ( 08 Guage ) , G.I Wire ( 10 Guage ) , G.I Wire ( 12 Guage ) , Flexible Wire 1.5 Sq.Mm X 2 Core Copper , Service Wire 2.5 Sq.Mm Isi Mark 2 Core , Service Wire 6 Sq.Mm Isi Mark 2 Core , Service Wire 10 Sq.Mm Isi Mark 2 Core , 2 X 1.5 Sq Mm. Fr Copper Pvc Sheathed Wires , 25 Amp, 32 Amp Three Phase L / T Contactor , Insulation Tape , 50 Mm Outside Dia. Double Wall Corrugated Pipes ( Dwc ) Of Hdpe For Enclosing Cable Below Ground / Road Surface, To Required Depth Complete. , Light Poles Painting In Silver Colour , Old Pole Shifting, Rework And Foundation Work Per Poleetc. , Pcb For Led Fittings Upto 26W-45W , Pcb For Led Fittingsupto 66W-75W , Pcb For Led Fittingsupto 76W- 100W , Driver For Out Door Led Fittings Upto 26W-45W , Driver For Out Door Led Fittings Upto 66W-75W , Driver For Out Door Led Fittings Upto 76W- 100W , 6 M High ( Clear Height ) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 130 Mm A / F, Top 70 Mm A / F O , 7 M High ( Clear Height ) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 130 Mm A / F, Top 70 Mm A / F , 9 M High ( Clear Height ) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 155 Mm A / F, Top 70 Mm A / F , 10 M High ( Clear Height ) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 175 Mm A / F, Top 70 Mm A / F , 12 M High ( Clear Height ) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 240 Mm A / F, Top 90 Mm A / F , Ms Pipe Pole B Grade 80 Mm Dia 6 Mtr Long With Pole Cap, Base Plate. , Mstubular Swaged Pole6 M Long With Pole Cap, , Mstubular Swaged Pole7 M Long With Pole Cap, , Mstubular Swaged Pole8 M Long With Pole Cap, , Mstubular Swaged Pole9 M Long With Pole Cap, , Frp Box Of Size 300 X200 X125 Mm 2.7Mm Thickness , 12W Led Bulb , 14W Led Bulb , 18W Led Bulb , 100 W Bulb , 200 W Bulb , 16 Amp Kitkat Fuse , 63 Amp Kitkat Fuse , Procelain Reel , Retrofit T8 Led 18 / 20 Tube Light , Lamp Holder China Clay , Lamp Holder ( Pendent ) , Quattz Electronic Time Switch , Cement Street Light Pole Clamp With Nut Bolt , M.S. Street Light Pole Clamp With Nut Bolt , Providing Rental Basis Hydraulic Bucket Vehicle Of Highth 9 Mtr. And Weight Capacity 200 Kg With Driver, Oprator And Disel Etc. For Per Day Basis.. , Supplying And Erecting Outdoor Stand Mounted Feeder Pillarfor Highmast Of The Same Manufacturer With 63A Tpn Mcb Incomer, Single Dial Timer Switch, 45A Tp Contactor Forautomatic Switching Of Luminaries, 2 Nos 9A Contactors And Raise / Lower Push Button, And Provision For Termination Of Adequate Size Of Incoming And Outgoing Cables Erected In Min. 14 Swg Crca Sheet Box Powder Coated With Supporting Angles, Self-Lock, Gasket And Slanting Top Erected With Cc Foundation , Making Cement Concrete Foundation Including Excavation ( 60 X 60 X 150 ) Cm Deep In 1:3:6 Cement Concrete 20 X 25 Mm Stone Metal, ( 45 X 45 X 45 ) Cm / 45 Cm Dia. X 45 Cm Height Plinth Duly Plastered, With Necessary Curing And Finishing Complete. ( Above 6 M To 9 M Poles ) , Making Cement Concrete Foundation Including Excavation ( 60 X 60 ) Cmx Deep 1 / 6 Of Pole Length In 1:3:6 Cement Concrete 20 X 25 Mm Stone Metal, ( 45 X 45 X 45 ) Cm / 45 Cm Dia. X 45 Cm Height Plinth Duly Plastered, With Necessary Curing And Finishing Complete. ( Above 9 M Poles ) , Providing Pipe Type Earthing With 40Mm. Dia. G.L. Pipe Or 20 Mm Dia. G.L. Rod Complete With All Materials , 1.25 Mm Crca Sheet Metal Enclosures With 20A. , 16 M ( Clear Height ) High Mast ( Top 150 Mm, Bottom- 410Mm ) With Lowering And Raising Motorized Unit, Lantern Carriage Assembly Suitable For Max. 12 Nos. Luminaries And Its Control Gear Box, Lightning Finial Arrangement For Fixing Aviation Light And Foundation Bolts , 12.5 M ( Clear Height ) High Mast ( Top 150Mm, Bottom- 360Mm ) With Lowering And Raising Motorized Unit, Lantern Carriage Assembly Suitable For Max. 6 Nos. Luminaries And Its Control Gear Box, Lightning Finial Arrangement For Fixing Aviation Light And Foundation Bolts On Provided Foundation As Per Specificationbajaj Make Make No. Oh-Pl / Hm , Pvc Armoured Cable 4Core 6Sq Mm , Pvc Armoured Cable 4Core 10 Sq Mm , Pvc Armoured Cable 2Core 10 Sq Mm , Pvc Armoured Cable 2Core 6 Sq Mm , Pvc Armoured Cable 4Core 16 Sq Mm , Pvc Armoured Cable 4Core 25 Sq Mm , Fpmcb 40A To 63A In Provided Distribution Board , Xlpe Armoured Cable 3½ Core70sq. Mm. Aluminium Conductor , Xlpe Armoured Cable 3½ Core95sq. Mm. Aluminium Cable , Xlpe Armoured Cable 3½ Core120sq. Mm. Aluminium Cable
Contract Date: Nov 03, 2022 Contract Value : 2.48 Lakh
Government Departments No of Bidders 4
Maharashtra View Result →
38.
Defence #9519801 AOC
Tender For Improvement To Lt Network Panels Along With Associated Earthing And Allied Works At Af Stn Bagdogra; 1 Demolition and removal of existing brick tiles or terracing tiles, single layer on roofsincluding wire brushing and cleaning top surface of cement concrete, including flashings and junction of parapets, etc and removing debris/rubbish materials out side MoD land, complete all as secified and as directed. 2 Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings including ridges,complete all as specified and as directed 3 Dismantling plain or corrugated steel sheeting any gauge thickness inclding Nainital or similar pattern roof coverings, complete all as specified and as directed 4 Dismantling of wrought iron or mild steel work of any description or otherwise provided, complete all as specified and as directed. 5 Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified and directed. 6 Demolition of (Un reinforced) Cement Concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and directed. 7 Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) andrubbish off the premises complete all as specified and directed. 8 Taking down chowkhats or frame with shutters without taking of shutters from frames not exc. 1.5 Sqm each inclding making good disturbed portion, complete all as specified and directed. 9 Taking down chowkhats or frame with shutters without taking off shutters from frames exc 1.5 Sqm but not exc 4.00 sqmeach including making good disturbed portion, complete all as specified and directed. 10 Demolition of brickwork built in cement mortar or cement lime mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as per specified and directed. 11 Taking down cement plaster of any description on brick work or stone masonry walls including rackingout joints, hacking for key, scrubbing down with water etc complete all as specified and directed. 12 Dismantling of existing water tanks of steel/PVC/AC of capacity exceeding 250 liters but not exceeding 500 litres, complete all as specified and as directed. 13 Taking down 15mm dia bore steel tubing and connections including cleaning for re-fixing or removal from site, complete all as specified and directed. 14 Taking down 20mm dia bore steel tubing and connections including cleaning for re-fixing or removal from site, complete all as specified and directed. 15 Dismantling of Rolling Shutter including all accessories etc., complete all as specified and directed. 16 Demolition and breaking updrain pipes (Salt glazed stone ware orconcrete) of 150mm dia (Internal), set in cement mortar, including taking out from trenches if required with demolition of concrete bed and removing from the site, complete all as specified and as directed. 17 Dismantling and breaking updrain pipes (Salt glazed stone ware orconcrete) of 100mm dia (Internal), set in cement mortar, including taking out from trenches if required with demolition of concrete bed and removing from the site, complete all as specified and as directed. 18 Taking out of MCBs for existing DBs and refixing to the same in new 4 way TPN DBs, complete all as specified and as directed. 19 M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.50 mm graded stone aggregate, rough finished as in levelling course on roof, complete all as specified and directed. 20 M&L for preparation of concrete surface by cleaning of roof surfaces with wire brushes and applying 15 mm thick plaster in CM (1:4) mixed with water proofing compound as per manufacturers instruction, on roof slab, finished even and smooth without using extra cement, complete all as specified and directed. Notes : WPC shall be measured and paid seperately. 21 M&L for water proofing treatment to roof slabs by applying one coat of bituminious/polymerized primer confirming to IS -3384 @0.30 litre/Sqm, by lying actetic polypropylene (APP) modified membrane prefabricated, reinforced with non-woven polyester, of 3.0 Kg/Sqm(minimum) 3mm thick with minimum 100mm side overlaps and minimum 150mm end laps and applying one coat of bituminious aluminium paint over APP membrane, complete all as specified and directed.. 22 M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated/semi corrugated/Trapezoid steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and as directed 23 M&L for Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed 24 S&F steel workin tubular trusses(Square/ rectangular) including special shaped washer etc. complete using ERW or induction butt welded tubes comfirming to IS-1161- 1998grade St-240, complete all as specified and as directed. 25 S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required hooks (stay) heavy for large gates, hook and pintle hinges large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. 26 M&L for preparation of new steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coat of redoxide primer, complete all as specified and as directed 27 M&L for preparation of old painted steel / iron surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed. 28 S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm longNon asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws, complete all as specified and directed. 29 M&L for 75mm thick PCC 1:3:6 type C2 (using 40mm graded aggregate) as in plinth protection/ path/ paving etc. laid in panels, finishing the top surface even and smooth without using extra cement, complete all as specified and directed. 30 Roughening surfaces of old concrete floor by picking, scrubing, sweeping clean and washing down with water to remove dust, etc.complete all as specified and directed. 31 M&L for machine cut kota stone slab 20-25mm thick as in flooring laid & jointed with cement slurry mixed with pigment to match the shade of the slab including cutting, rubbing and polishing including 20mm thick screed bed in CM 1:4, complete all as specified and directed. 32 M&L for kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over on vertical surface of wall and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including 10mm thick rendering in CM (1:4), complete all as specified and directed. 33 M&L for Vitrified Ceramic tiles light shade 8-10 mm thick, area of each tiles not exc 0.36 Sqm, in floors, set and jointed in neat cement slurry and pointed in white or coloured cement including 15mm thick screed bed in CM 1:6complete all as specified and directed. 34 M&L for Vitrified Ceramic tiles light shade 8-10 mm thick, area of each tiles not exc 0.36 Sqm, in skriting/vertical surface, set and jointed in neat cement slurry and pointed in white or coloured cement including 10mm thick rendering in CM 1:4, complete all as specified and directed. 35 M&L for non skid coloured ceramic floor tiles of size exc. 0.11 but n.exc.0.18 sqm each, 7-8 mm thick laid in floor set, jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6, complete all as specified and directed. 36 M&L for colour glazed ceramic wall tiles of size 450x300x7mm thick on vertical surfaces on vertical surface of wall, set and jointed in neat cement slurry and pointed in white or coloured cement to match including rendering 10mm thick in CM (1:4)complete all as specified and directed. 37 S&F powder coated aluminium (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified and directed. 38 S&F 4 mm thick one side frosted sheet glass ordinary quality and glazing in square n.exc 0.5sqm in each pane fixed withneoprene rubber gasket in aluminium frame, complete all as specified and directed. 39 S&F powder coated aluminium (minimum thickness of powder coating 50 micron) door shutters, aluminium section weighing not less than 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, powder coated aluminium fittings such as handles - 02 Nos, 100mm long hinges - 03 Nos, sliding bolt - 01 Nos, tower bolt - 02 Nos in each door, powder coated aluminium snap beading and rubber gasket, screws etc., complete all as specified and directed. Note:Glass shall be measured seprately. 40 M&L for 5.5 mm thick sheet glass ordinary quality and glazingeach pane fixed with neopunerubber gasket in aluminium frame work, complete all as specified and directed. 41 S&F Solid PVCdoor frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet reinforced with M.S. tube, suppling & fixing in opening as per specification & drawings, complete all as specified and directed. 42 S&F factory made solid PVC moulded door shutters with particle board core 28 to 30 mm thick (stiles), with 2,4 or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm Plain colour PVC Sheet on back face ,supplying & fixing in frame at site as per specification & drawing, complete all as specified and as directed. 43 S&F 1.25 mm thick pressed steel frame of size 105X 60 mm for door with one ore more rebate includings necessary fixing lugs, stainless steel hinges, locks strike plate etc., complete all as specified and as directed. 44 M&L for PCC 1:3:6 type C1 (using 20 mm graded aggregate) for holdfast blocks, complete all as specified and as directed. 45 S&F factory made 35mm thickflush shutters solid core construction with block board and plywood face pannel commercial type on both faces, complete all as specified and as directed. 46 S&F for 100mm long mild steel (cold rolled) butt hinges, medium weight, complete all as specified and directed. 47 S&F 150mm long extruded aluminium alloy handles, fabricated type anodised, complete all as specified and directed. 48 S&F 300 mm long aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixing with accessories, complete all as specified and directed. 49 S&F 150mm long aluminium anodised barrel tower bolt ofextruded section, complete all as specified and directed. 50 S&F aluminium (extruded section body) door closer hydraulically regulated, designation No 3, universal type, suitablefor door shutters 851 mm to 1000 mm in width and of weight between 61 to 80 kg and fixed, complete all as specified and directed. 51 M&L for welded steel wire fabric weight not exceeding 4 kg per square metre supplied and fixed complete to wood or steel members, complete all as per specified and directed. 52 M&L for brickwork with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6, complete all as specifed and directed. 53 M&L for 15 mm thick rendering in CM (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement on wall, complete all as specified and directed 54 M&L for preparation of new plastered wall surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over 1.5mm thick wall care putty, complete all as specified and directed. 55 M&L for 15 mm thick rendering in CM (1:4) onfair faces of brick work or concrete surfaces finished even and smooth without using extra cement, complete all as specified and directed. 56 M&L for 5mm thick rendering in cement mortar 1:3 on fair faces of concrete surfaces without using extra cement on ceiling, complete all as specified and directed 57 M&L for preparation of new plaster surface of ceiling and applying two coats of white wash, complete all as specified and directed. 58 M&L for preparation of newly plastered surfaces of wall and applying two coats of Weather Proof Exterior Emulsion paintover a coat of suitable primer on walls, complete all as specified and directed. 59 M&L for complete removal of existing treatmentand applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over prepared surfaces, complete all as specified and directed. 60 S&F 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I, complete all as specified and directed. 61 S&F ball valve 20mm high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, complete all as specified and directed. 62 S & F in repair 20mm bore gate valves with iron wheels head screwed both ends for iron pipe and fixed, complete all as specified and directed. 63 M&L for cutting chasing pinning in making good to facing where required for concealed water tubing etc n. exc 10 cm girth in brick wall, complete all as specified and directed. 64 S&F 15mm bore unplasticised PVC pipes of pressure rating 10 kgf/Sq cm fixed to wall or ceiling or laid in floors including fittings etc., complete all as specified and directed. 65 S&F 20mm bore unplasticised PVC pipes of pressure rating 10 kgf/Sq cm fixed to wall or ceiling or laid in floors including fittings etc., complete all as specified and directed. 66 S&F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, complete all as specifed and directed. 67 S&F in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed 68 S&F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, complete all as specifed and directed. 69 S&F in repair 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed. 70 S&F in repair PVC (SWR) vent cowl 110mm bore, complete all as specifed and directed. 71 S&F in repair 110 mm bore PVC (SWR) bends any radius, complete all as specifed and directed. 72 S&F in repair PVC (SWR) Bend radius any radius 75mm bore, complete all as specifed and directed. 73 S&F in repair PVC (SWR) junction single, (single T) equal or unequal 110mm bore, complete all as specified and as directed 74 S&F in repair PVC (SWR) junction single, (single T) equal or unequal 75 mm bore, complete all as specified and as directed 75 S&F in repair PVC (SWR) floor trap plain with gratinghaving dia meter of out let 75mm including jointing with solvent cement to waste pipe fixed in cement concrete type B-1 (1:2:4), complete all as specified & as directed. 76 S&F in repairs sheet glass shelf glass assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long fixed with chromium plated brass screws, complete all as specified and as directed 77 S&F in repairs CP soap dish size 160X160X90mm fixed to wall with screw complete all as specified and directed. 78 S&F in repairs 20 mm dia aluminium anodised tubular towel rail, D type, 60 cm long between flanges fixed with brass screws complete all as specified and directed. 79 S&F in repairs 15 mm bore chromium plated fancy type angle valve with elegant knob screwed down high pressure, with crutch or butterfly handle screwed for iron pipe or for unions, complete all as specified and directed. 80 S&F in repairs 15 mm bore chromium plated fancy type bib taps with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed. 81 S&F in repairs 15 mm bore chromium plated fancy type pillar tap for WHBs with capstan heads, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed, complete all as specified and directed. 82 S&F in repairs, PVC connection 15mm dia and 450 mm long with 2 Nos PTMT nuts with washers, complete all as specified and directed. 83 S&F in repairs PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic actiontype with inlet ball valve and float, handle with & including bracket andPVC flush pipe 32 mm borecomplete all as specified. 84 S&F in repairs 600 mm x 450 mmsize beveled edge mirror of selected quality glass, 5.50 mm thick, mounted on 6mm thick AC pain buildingboard or commercial plywood and fixed to wall with wooden plugs and chromium plated brass screws & cup washers complete all as specified and as directed. 85 S&F in repairs vitreous china, Sqatting pan, Orissa Pattern, size 580 mm x 440 mm white, withintegral foot rests (excluding flushing cistern and flush pipe) and including 100mm bore ‘P’ or ‘S’ trapand provision of cement concrete bedding and connected to existing flush pipe, complete all as specified and as directed. 86 S&F in repair vitreous china wash hand basin (flat back) of size 550x400mmincluding one number chromium plated waste fittings, 32 mm dia, brass with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed, with & including 32 mm dia PVC waste pipe with connector,including cutting for and pinning in ends of brackets complete all as specified and as directed. 87 Excavation in trenches not exc. 1.5m wide and not exc 1.5m in depth for foundation or for taking out or laying pipe linesetc and getting out in soft/loose soil, complete all as specified and as directed. 88 S&F in repair 25 mm outer dia medium weight pipe made out of stainless steel 304 grade, includingdecorative ornamental knobs at both ends and one set of ornamental decorative Stainless steel clamps tofixed towalls, complete all as specified. 89 S&F stainless steel 304 grade clamps with ends/stops etc.including other accessoriesfor fixingarrangements of25mm mm dia curtain rodto wall, complete all as specified and as directed. 90 S&F Stainless steel 304 grade ornamental knobs for side of curtain rods includingfixingarrangements, complete all as specified and as directed. 91 S&F powder coated aluminium sliding window shutters 25 mm thick with frames (consisting of two nos glazed shutters and one no gauze shutter)3 track sliding shutters, duly fitted with neoprene beading glazing clip, locking device, heat absorbing glass 5 mm nominal thickness in glazed shutters, stainless steel wiremesh of 0.254mm nominal dia of wire and 0.95mm average width of aperature in gauzed shutter, complete all as specified and as directed. 92 S&F fabricatedpowder coated anodized aluminium grill of size 75x75 mm, using 6mm dia bars fixed to outer portion of chowkhat using U/V section runners, complete all as specified and as directed 93 M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel painting over a coat of pink primer, complete all as specified and as directed. 94 M&L for preparation of old wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. 95 S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5sqm in each pane, complete all as specified and as directed. 96 M&L for complete removal of existing treatment of surfaces and applying two coats of oil bound distemper over 1.5mm thick wall putty, complete all as specified and directed. 97 S&F Steel rolling shutters, thickness of laths 1.25mm, with ball bearing, as specified including top cover, anchoring rod, hasp and staple, 2 lever locks and one shop coat of primer; erected in position complete push but gear operated type with bevel gear box and crank handle, complete all as specified and directed. 98 S&F Ball bearing for rolling shutters, complete all as specified and directed. 99 Supply only intergral water proofing compound, complete all as specified and directed. 100 M&L for cement concrete 1:4:8type D-2(using 40mm graded aggregate) as in foundations, filling and mass concrete, complete all as specified and directed. 101 S&F Mild steel framed work such as framed guard bar conforming to Fe 290,Gde-E-165, complete all as specified and directed. 102 M&L for surface dressing n. exc 15 cm deep in any type of soil, complete all as specified and directed. 103 M&L for hardcore of broken stone or aggregate of gauge n. exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed. 104 M&L for75 mm thick PCC (1:4:8) type D2 using 40 mm graded stone aggregate as in sub base etc., complete all as specified and as directed. 105 M&L for designed, pre painted coloured chequered cement concrete tiles of 300x300x25mm size set, jointed & pointed in neat cement slurry with grey cement and pigments , laid over 20mm thick screed bed in CM 1:6 finished with pigments match the shade of tiles, complete all as specifeid and directed. 106 M&L for sand cushioning to receive interlocking tiles including spreading, levelling in layers, complete all as specifeid and directed. 107 M&L for machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 grade with grey cement andpigment, complete all as specifeid and directed. 108 M&L for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in coping/kerb stone etc., complete all as specified and as directed. 109 M&L for excavating in post holes (or similar holes) each n.exc 0.5Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25CM, in soft and loose soil, complete all as specified and as directed. 110 M&L for cement concrete 1:2:4 type B-2 (using 40mm graded aggregate) as in foundations, filling and mass concrete in post, pillars, complete all as specified and as directed. 111 Supply only 4mm dia Chain link MS galvanised fencing, weight not exceeding 4kg per sqm, complete all as specified and directed.Note :- Weight of chainlink fencing shall be ascertained by BOO. 112 Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire, complete all as specified and directed. 113 M&L for mild steel framed work as in doors, gates of angle iron, flat ironor other section with gusset plates, rails, braces, hold fast, pin and pintol hinges, sliding bolt etc. complete, drilled for fixing of steel sheeting or other covering doors etc. to beprepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitting (exclusive of steel sheeting or other covering, running rails and guides ) and hanging; also fastening and fixing, complete all as specified and as directed. 114 S&F mild steel works as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to e-290 Gde E-165,complete all as specified and as directed. 115 Supply only mild steel round bar 10 mm dia and over for tying chain link fencingetc., complete all as specified and directed. 116 Supply screw bolts (machine made) with hexagonal or square head at one end and rounded the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5 cm but n.exc 10 cm and dia of shank 11 to 15mm and fixed in position, complete all as specified and directed. 117 M&L for 0.80mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, complete all as specified and directed. 118 M&L for preparation of new or untreated steel and iron surfaces of any description not exc.10 cm in width or girth and applying two coatsof synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. 119 S&F in repairs, Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured), complete all as specified and as directed 120 M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregates as in concrete bed to drain pipes including packing under and haunching against the side of pipes,laid, jointed and tested for 150mm bore pipe, complete all as specified and as directed 121 M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregates as in concrete bed to drain pipes including packing under and haunching against the side of pipes,laid, jointed and tested for 100mm bore pipe, complete all as specified and as directed 122 M&L for salt glazed stone ware (SGSW) drain pipe, 150mm dia (Internal), grade ‘A’ laid in trenches and jointed including testing, complete all as specified and as directed. 123 M&L for salt glazed stone ware (SGSW) drain pipe, 100mm dia (Internal), grade ‘A’ laid in trenches and jointed including testing, complete all as specified and as directed. 124 Removing excavated materials (soil) to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified and as directed. 125 Returning, filling in,soft/loose soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and as directed. 126 M&L for soakage well including excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size of 1.80m dia and 3.00 m deep,complete all as specified and as directed. 127 M&L for 5500 ltr capacity LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc.,complete all as specified and as directed. 128 Taking down/up XLPE cable of 10 sqmm to 16 Sqmm 2 core complete with bricks & GI pipe complete all as specified and directed. 129 M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts Earthed, grade cross sectional area 16 Sqmm 4 Core, complete all as specified and as directed. 130 M & L for Earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the galvanised iron strip 32 x 6 mm, by means nut bolt, nuts, check nuts and washer of the GI Earth strip protected by provision of GI light grade pipe 40 mm, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh andearth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion, complete all as specified and as directed.. 131 Supply, installation, testing and commissioning of 11 KV Compact Substation (CSS) out door type plinth mounted, enclosure having construction of Powder Coated/ Galvanised sheet steel of 1.6 mm thickness for non load bearing and 2.0 mm for load bearing partition sheets, and door with HRCA 4.00 mm base frame. The enclosure shall have IP54 degree of protection for HT< switchgear components and IP34 degree of protection for Transformer component. Each components will be provide with corrosion resistance and all side openable hinged door and lock and key arrangements. Heavy lifting lugs with all equipments load. Necessary danger plates outside of the CSS. The compartment illumination lamp with door operated switch shall be provided for all the compartment including necessary foundation and earth work as per manufacturers recommendation and as per the site conditions (drawing and specifications of the foundation recommended by the manufacturer to be approved by GE before commencement of thework, thequoted ratesare deemedto beinclusive ofthe same). The CSSis comprising of the followings :- 132 (Srl Item No. 131.00 Contd...)HT SWITCHGEAR:-11 KV, Non -extensible 2 WAY (1 LBS+ 1 VCB) Non- Extensable RMU compact switchgear consisting of 1 nos direct Module (LBS) and 1 No 630 Amps VCB fixed operated Manual and spring charging & closing, electrolyte grade copper busbar 11 KV/630 Amps VCB in SF6 insulated stainless steel enclosure with series trip, self-powered microprocessors numerical over current and earth fault relay protection, HT cable/Bus Bar , and one metering module with necessary CTs and PT and digital panel mounted multifunction meter with class 1.0 accuracy, comprising the following:- (Complete unit is to be installed inside CSS, protection accessories , Enclosure : Metal Clad, IP-54 Protection. Protection Relay: Self Powered Alfa numeric LCD display type. Internal arc tested for 1 sec, Fully compartmentalized sheet steel enclosure with automatic safety shutters, GI foundation bolts with provision of cable terminating facilities with powder coated smooth glossy finish and as per follows: -Rated Voltage - 12 KV , Rated Frequency - 50 Hz., Rated continuous current rating - 630 Amps. , Rupturing capacity of VCB --350 MVA, Rated Interrupting Current - 21 KA. , Rated making current for VCBs- 52 KA. , Rated making current for Isolators - 62 KA. , Rated short time current for 3 sec - 21 KA , Operating duty - O-3min-CO -3min.-CO , Power frequency withstand voltage - 28 KV , Impulse withstand voltage - 75 KV , Busbar rating - 120% of continuous current., Operation: Spring closing mechanism - DC motor operated with 24-volt supply, Breaker Closing - Manual & Electrical through TNC switch., Shunt Trip coil - 24 V DC, Safety Interlock Locking faciality - Required., Breaker panel indication - ON (Red) OFF (Green)Accessories: 1 No. Self Powered Relay, Mechanical counter, Space Heater with Thermostat, Fuse and ON/OFF Switch, Aux relays for remote trip/indication for PC interface etc, cubicle illumination lamp LED 5 watt retrofit type 230 V AC, T-N Switch, Anti pumping contractor etc. In addition to the above all standard fittings to be provided as per IS normsMimic Diagram: An operating mimic diagram shall be provided on the front side of each cubicle.Note: - Circuit breaker complete will be obtained directly from the OEM and not from the authorised system assemblers of OEM. The installations, calibration and testing of SF-6 circuit breakers will be conducted in the presence of authorised representative of OEM by the Contractor. Power pack of 230V AC, 24DC of minimum 30min backup for RMU is included in the item rate and rating of battery as described by OEM. 133 (Srl Item No. 131.00 Contd...) 11KV/0.433KV OIL TYPE TRANSFORMER OF 500KVAOil filled Type 3 phase, 50 Hz, Dyn11, ONAN type Sealed type Copper wound Transformer with Off Load Tap Changing Arrangement on HV side in steps of 2.5% , +5% to -10% having cable end boxes on HV side suitable for 3 Crore X 300 Sq. mm. XLPE cable of 11 kV grade on HT side and Busduct inLV side complete with all accessories like buchholz relay, Oil temperature indication, windingtemperature indication and alarm etc preferbly DMCR Protection Relay i/c first filling of filtered dehydrated K Class natural Ester Oil bioTransol (as per IS 16659) and confirming to IS 1180 and losses shall be as EEL-2 confirming to IS-1180 Part-I:2014 as per latest 4th amendment in Mar 2021 & 100%loadi/c as per specification below complete in all respects as required at site including first filling of transformer oil. Design ambient to be considered as 50 Deg C. All the balance parameter like temp rise, Basic insulation level, flux density etc shall be strictly in accordance with IS 1180 Part - 1 only. Heat Run Test is the mandotary test for each Transformer Standard: The equipment shall confirm to the latest edition of applicable standards as follows. In case ofconflict between applicable standards and this specification, this specification shall govern.• IS 2026 Standard for Oil filled Transformer• IS:3639 for Fittings and Accessories• IS:2099 for Bushings > 1000 V• IS:7421 for Bushings < 1000 V• IS:1271 for Electrical Insulation classified by Thermal stability• IEC 62770 Natural Ester Oil• CBIP Guidelines. oil Insulation class : K class. It should also exhibit safety against fire hazards 134 (Srl Item No. 131.00 Contd...)CORE : Transformer shall be double wound, core type with low loss, non-ageing, high permeabilityPRIMEGRADE, CRGO with M4 Grade or Better, perfectly insulated and clamped to minimize noiseand vibrations. Followings should be Mandatory for any manufacturer: -a. Transformer shall be of BOLTLESS core design 135 (Srl Item No. 131.00 Contd...)LT PanelLT panel- Separate compartment for LT network inside the CSS made with 2.0mm CRCA sheet with necessary angle iron frame, dust and vermin proof, with separate openable door for LT side with necessary locking arrangement, opening for LT AL Busbar/cable entry, opening for natural air ventilation/cooling, necessary suitable range of panel mounting Multifunction Meter (6400NG), CTs etc as required with ACB 4 pole Icu=Ics=Icw(1sec) = 50kA @ 440V AC 50 Hz of breaking capacity 50KA, with EDO type, Microprocessor based overcurrent, short-circuit and earth fault release of capacity 800 Amps -01 Nos ( Main incomer of LT) and including the followings LT distribution ( i.e. LT out going).LT Outgoing: -(i) MCCB 4 pole 415-volt 50 Hz of breaking capacity 36KA, 250 Amps, Ics=100% Icu TMD overload and short circuit protection with Encapsulated double break roto technique ensures outstanding current limiting capability - 3 Nos.(ii) MCCB 4 pole 415-volt 50 Hz of breaking capacity 36KA, 200 Amps, Ics=100% Icu TMD overload and short circuit protection with Encapsulated double break roto technique ensures outstanding current limiting capability - 3 Nos.(iii) MCCB 4 pole 415-volt 50 Hz of breaking capacity 36KA, 160 Amps, Ics=100% Icu TMD overload and short circuit protection with Encapsulated double break roto technique ensures outstanding current limiting capability - 2 Nos.(iv) Pre dispatch inspection at OEM factory premises shall be carried out by rep of Accepting Officer. The cost for the same is deemed to be included in quoted rates. Note :- The civil work for foundation of CSS shall deemed to be included in quoted rates. 136 M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 Sqmm 3 Core complete all as specified and as directed. 137 M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmmcomplete all as specified and as directed. 138 Disconnecting and shifting of transformer of capacity 200 to 315 KVA form one sub station to another sub station by mechanically and reconnect the same, complete all as specified and directed 139 Supply,installation, commissioningandtesting complete with all accessories of transformer of 33 KV capacity 5 MVA step down, outdoor floor mounted, double copper wound,3 Phase, 50 Hz, AC,Oilimmersed, ONAN confirming to IS-2026 and IEC62770 including cooling fans, external cooling tubes/radiator cores type havingvoltage ratio 33000/11000 volts (corresponding to principal tapping ) winding delta connecting on Primary side (HV Side) and star connected on secondary side (LV side) in accordance with vector symbol Dyn11 (vector Group) with neutral brought out on LV side and looping on HV side for contact output so as to alter/vary secondary voltage by (+) 5 to (-) 15% in equal steps of 1.25% to be changed by means of (OLTC) on load Tap Changer with RTCC and AVR. Supply ,installation of RTCC panel with AVR and marshaling box . Transformer shall be of BOLTLESS core design. Transformer shall be double wound, core type with low loss, non ageing, high permeability PRIME GRADE, CRGO with m4 grade or Better, Perfectly insulated and clamped to minimize noise and vibrations. 140 (Srl Item No. 139.00 Contd...)The transformer shall confirm to the latest edition of applicable standard as follows :-(i) IS-2026, for tests and tolerance of guarnteed Particulars. (ii) IS-3639 for Fitting and accessories. (iii) IS2099 for Bushing >1000V. (iii) IS-7421 for Bushing <1000 V (v) IS-1271 for Electrical insulation classified by Thermal stability. (a) Winding (iv) HV Winding -Layer/disc winding(i) LV Winding-Helical/Disc widing(b) Insulation Level (i) HV-170 (ii) LV-70 (c) Insulation level (Power frequency with Stand KVrms)(i) HV 70 (ii) LV-28 141 (Srl Item No. 139.00 Contd...)(d) Tapping Range -(+)5% to (-) 15% @1.25%(e) Tape Changer Type -On load Tap Changer +RTCC+AVR. (f) Temperature Rise (Oil/Winding) -50/55 Degree Centigrade(g) Hot spot temperature over a maximum yearly weight average ambient temp of 32 Degree Centigrade-98 Degree Centigrade(h) Termination HV/LV-Cable Box(j) Short Circuit thermal withstand time-02 seconds (k) %impedance at 75 °C clurrent and frequency (Subject to IS Tolrance) at 5 MVA base % 7.35(l) Load loss at rated current and 75 degree C (KW) (subject to IS Tolerance )at 5 MVA base -70(m) % load at which Max Efficency occurs %-33.81(n) Regulation at full load 0.8 PF%.-5.75The transformer should have following fitting and accessories :-(a) Cable Boxes on 11 KV secondary side for single core XLPE cable 3 Core 185 Sqmm(b) Outdoor 33 KV bushing insulator for connection through openconductor with sleeves.(c)Oil conservator with filling hole and cape drain valve and oil level guage.(d) Dehydrating breather wth connecting pipe first fill of dehydrating agent and oil seal.(e) Explosion relief vent mounted on tank with double diaphragm and equilliser pipe connection to conservator air space (Pressure release device)(f) Air relief plug.(g) Shut off valve between the conservator and buchholz relay.(h) Drain valve with threaded adopter. 142 (Srl Item No. 139.00 Contd...)(j) Filter valve with threaded adopter (Top and bottom).(k) Wheels (l) Rating plate and terminals marking plate.(m) Extra bushing for neutral out side the LV Side (n) Hand hole sufficient size to assess the interior of the tank.(o) First filling of the transformer oil.(p) Cover Lifting eyes.(q)Double float Buchholz relay with trip and alarm contacts.(r) 150mm dial type thermometer for winding temperature indicator having range0-12 centigrade vapor pressure type with maximum reading pointer/Max temperature indicator and resetting devicewith alarm/trip contact and additional contact for switching on the cooling fan.(s) Dial type thermometer for oiltemperature indicator with 02 sets of contacts for alarm and triphaving range 0-12 centigrade vapor pressure type with maximum reading pointer/Max temperature indicator and resetting devicewith alaram/trip contact .(t) Shut off valve between cooling tubes and tank.(u) Pressure Release Valve (PRV) with one set of trip contact.(v) Magnetic Oil gauage (MOLG) with one set of trip contact.(w) Earthing terminal for connecting earthing leadNOTE:-(i) The oil temperature and winding temperature guages shall be housed in a marshaling box made up of MS sheet as per manufacturer recommendations with hinged door and having glass front side of the box and provision for entry of cables and compression glands.(ii) The civil work for foundation of CSS deemed to be included in quoted rates.(iii) Pre dispatch inspection at OEM factory premises shall be carried out by rep of Accepting Officer. The cost for the same is deemed to be included in quoted rates. 143 Supplying , transporting, erectioning, testing and commissiong of 33 KV, 350MVA, 630 A, 50Hzvoltage class outdoor type Vaccum Circuit Breaker for use on system voltage 33 KV. The circuit breaker and accessories shall conform to IEC-62271-100 or IS 13118 and other relevant IEC/IS standard. The circuit breaker shall be complete with terminal connection, operating mechanism, control cabinets, piping, interpole cable accessories like gland, terminal block, lugs, 02 Nos level pressure switch scale. necessary steel support structure for CB and control cabinetThe circuit breaker shall be required to performs as per technical parameters given below:- 144 (Srl Item No. 143.00 Contd...)(a) Installation - Outdoor, 3-phase, Live-Tank, Porcelain Clad, Switchyard Breaker(b) Rated Voltage - 36 KV(c) Rated Current - 630A or higher(d) Power frequency with stand voltage (KV rms)- 70 KV(e) 12/50 microsecond lighting impuls with stand voltage (KV Peak)-170 kVp(f) Rated short circuit current breaking capacity (3 Sec ) at rated voltage specified 31.5 KA(g) Control Voltage incl. trip/close coil - 30V DC (h) Spring Charging Voltage - 230VAC(j) Symmetrical interrupting capacity (KA/RMS) 31.5 KA for 3 sec(k) Rated short circuit Making Current (KAP)-80A(l)Out of phase breaking capacity (KA rms) as per IEC(m) Rated operating duty as per IEC(o) Temp rise over the design ambient temperature -As per IEC 62271-100(n)Operating Mechanism -Spring (o) Creepage distance as per IEC-900mm (p) No of trip/close coil 30 V DC-02 Nos(q) Tripping system - 30 V DCNote:-(i) Cost of supply and fix of Outdoor type Terminal Kiosk (TK) havingterminals/disconnecting-links for termination of CT/PT wiring including PT secondary fuses complete all as required at site are deemed to be included in the quoted rate.(ii) Cost of construction of foundation including construction material and necessary earth work as per manufacturer design for breaker TK complete all as required at site are deemed to be included in the quoted rate. 145 (Srl Item No. 143.00 Contd...)(2) 33KV control & relay panel indoor type for Vaccum Circuit Breaker.The panel shall be with back access double door arrangement, dust and vermin proof , IP -4X class protection and made 2mm , CRCA MS sheet powder coated finsh over one coat of red oxide primer both side operating type, including internal wiring using 1.1kV FRLS insulated multistrand cable (2.5sqmm for CT/PT and control circuit, numbered and colour coded as per IS-5578/1984 having suitable entry for cable consisting of the following:-(A) Main, Numerical Protection Relay with LCD displaying mimic bay for ON/OFF control and monitoring of feeder current. Built in as of 11 KV VCB panel relay disturbance recorderand event logger to monitor the Sequence of Events (SoE) using upto 800 event codes. The relay shall be communicable SCADA system.(i) Over current and earth fault protection with minimum pickup at low set of 5% and 1% respectively(ii) Transient/intermittent earth fault protection(iii) Phase discontinuity protection(B) Flush mounted auxillary relays for:-(i) Trip Circuit Supervision(ii) Master Trip(iii) Fuse fail (PT) supervision operated (iv) DC supervision scheme(v) Overvoltage/ undervoltagereay within max value settings with reset(C) Metering(i) Metering Equipment incl. 01 x Digital Voltmeter (Acc.Cl.0.5), 01 x Digital Ammeter (Acc.Cl.0.5), 01 x Tri-Vector-Meter (Acc.Cl.0.5). (ii) 01no. Multi-Function-Meter (Acc.Cl.0.5) shall be provided with LCD display for measuring current, voltage, power, power-factor and energy-parameters, Total Harmonic Distortion and Max. Demand Indication, same shall be communicable on ModBus via RS485 port. 146 (Srl Item No. 143.00 Contd...)(D) Indicating Lamp. (i) Bus-01 Isolator ON/OFF. (ii) Bus-02 Isolator ON/OFF. (iii) Line Isolator ON/OFF/EARTH(iv) CB auto trip. (v) CB ON. (vi) CB OFF. ii) CB Spring Charge. iii) Trip circuit healthy. x) DC Available LED with push-button(x) R-Y-B Phase LED Indication(E) Semaphore indicator. (i) Circuit Breaker ON, OFF. (ii) Bus-01 Isolator ON, OFF. (iii) Bus-02 Isolator ON, OFF. (iv) Line Isolator ON, OFF, EARTH(F) Control switches/Push Buttons(i) Trip-Neutral-Close Switch for Circuit Breaker Control - 01no. (ii) MCB for AC isolation - 01no. (iii) MCB for DC isolation - 01no.(iv) Heater switch with thermostat - 01no. (v) 3-pin socket with ON/OFF switch - 01no.(vi) CFL Lamp with ON/OFF switch - 01no.(G) 08-Window Annunciator with hooter and Mute, Acknowledge, Reset and Test buttons for:- (i) OC Trip Alarm(ii) EF Trip Alarm (iii) Line Differential Trip Alarm (iv) PT Fuse Failure Alarm. (v) Trip Circuit Failure. (vi) Spare.(H) Test Terminal Block for CT(j) Thecost of construction of foundation as per manufacturer design,necessary PCC work, demolition of floors/walls of substation including foundation frame (supplied by OEM) for control panel as required at site are deemed to be included in the quoted rate.(k) Power pack of 230V AC, 24 DC of minimum 30min backup.(l) Pre dispatch inspection at OEM factory premises shall be carried out by rep of Accepting Officer. The cost for the same is deemed to be included in quoted rates. 147 Supply and installation of 33 KV, single phase, out door oil cooled CT of ratio 400/5-5 Amp, class 1.0 / 5P10, burden 15 VA ,complete all as specified and directed 148 Supply and installation of 33 KV single phase out door oil cooled PT of ratio 33 KV/rt3/110 V/rt3/110V/rt3, Class 0.5-3, Burden 50 VA – 50 VA, complete all as specified and directed 149 Supply and fixing lightning arrestor HT 33 KV, 10 KA,station class, complete all as specified and directed. 150 Supply and fixing HT 33 KV out door type gang operated air-break switch suitable for horizontal or vertical mounting fixed type complete with 9 insulators and with earth switch upto 400 Amps, complete all as specified and directed. 151 Supply ,install ,testing and commissioning of outdoor type floor mounted metal clad 11 kV ,VCBhaving rupturing capacity 350 MVA of rating upto 630 Amp. with 1 way - ICOG, totally enclosed fully interlocked draw out type breaker as per IEC 62271-100 & IEC 62271-200, as amended upto date and additional specification, having capacities as mentioned below, single break, trip free mechanism, manual/spring charging and auto/ manually closing breaker suitable for use on 11 KV, 3 phase, 50Hz AC supply with short circuit fault level of 25 kA for 0.1 sec , Panel shall be full internal arc tested i.e. in all three chambers at 25 kA for 0.1 sec for safety purpose (AFLR). complete with self contained, fully interlocked, breaker featured with mechanical on/off indicator with hand trip device, spring release coil, S/T coil and auxiliary switch of 6 NO+ 6 NC and equipped with following switch gears and accessories including in the connection suitable for upto 3C x 1R X 185 sqmm XLPE 11 KV cable (cable entry from Bottom side) end termination. Panel shall have micro processor based numerical relay with O/L, S/C,instantaneous, E/F. Arc flash protection to operate on Current and light for faster tripping in Cable, Bus Bar and Breaker Chembar. Panel shall have made with Aluzinc frame.The HT panel shall be compatible for applications and shall be complete with compatible hardwares. And all meters should be provided with RS 485 port with modbus. Endurance Class of VCB should be E2-M2-C2 and Number of fault breaking should be 10,000 Nos for reliability & Ease in operation. Rack-in & Rack-Out operation should be floor rolling design Make of Vacuum interrupter, circuit breaker, Panel, relays & meters shall be same. There must be a viewing window on VCB chamber door and same must be as per Internal arc test report. The basic insulation level of entire panel shall be 28 KV(RMS) / 70KV(Peak). For easy access of document like catalogue, O&M and drawing there should be QR code, pre- configured on the product Approved.Incommer - 1 Nos1 No. Vacuum Circuit Breaker - 630 A, 11 KV, 50 Hz, 3 phase, 25 kA for 0.1 sec, Breaker comes as completely sealed pole assembly to ensure long term performance Breaker control switch. 152 (Srl Item No. 151.00 Contd...)03 No. 11 KV/√3/110V/√3/110V/√3 class 1.0/3 P 50VA accuracy with 1 No. voltmeter (0- 36KV), digital type, selector switch for voltmeter and MCB for HT metering upt 11KV on incomer.1 No. 0-800A digital Ammeter with selector switch. 1 No. Trivector / MFM meter, communicable RS 485 port for MODBUS TCP- IP protocol 1 No. micro processor based with Modbus TCP-IP communication protocol numerical relay 1 set of dual core dual ratio 3CTs 125- 75/1A/1A of suitable burden and accuracy class 0.5 for metering and class 5P10 for protection.Master Trip circuit relay.Restricated earth fault protection shall be part of main protection relay. Over current IDMT & Instantaneous numerical relay with communication port suitable for Modbus TCP-IP . For the same one core of PS class to be added in CT Alarm annunciator for all i/c, tie breaker, buscoupler and outgoing HT VCBwith 12 windows with ACK, rest, test push button for transformer faults and electrical faults.Suitable space for termination upto 1No. 3 C x 185 sqmm XLPE cable outgoing feeder.1 Panel HT Board complete as required, as per single line diagram and specification. Indication Lamp shall be as required Wireless thermal sensors on Bus Bar Joints and Cable termination should be provided along with wireless Climatic sensors Suitable arrangment to capture the data and through PLC and gateway should be visible on HMI of panel, and these date should be possible to view on BMS/SCADA (if availble) Cable Box to be provided for ICOG Panel. Power pack of 230V AC 24 DC of minimum 30 minutes backup.Note :- (i) PCC platform/plinth shall be constructed as per OEM recommandation and rate for the same shall deemed to be included in quoted rates. (ii) Pre dispatch inspection at OEM factory premises shall be carried out by rep of Accepting Officer. The cost for the same is deemed to be included in quoted rates. 153 Supply, install, testing and commissioning of 11 KV, 3ph, 50Hz, indoor type, totally enclosed metal clad switch gear, floor mounted, complete with Vacuum circuit breaker having rupturing capacity 350 MVA, 630amp, insulation level-12KV/28KV/ 75KVP, SC rating-26.3 KA for 3 Sec. IEC Ref- 62271-200 or latest updated, overload and earth fault protection, ampmeter, voltmeter and of current rating not less than 800 Amps including necessary connection with existing cables including following details specification all as specified and directed.:-(i) (a)Digital numerical relays for earth fault, over current protection and models as directed by OEM .(b) high speed trip relays.(c ) Closing coil, trip coils of 110V, DC(d) VCB will be horizontal break and horizontal draw out type.(e) VCB panel shall be suitable for local/remote control.(f) The panel will be provided with LED indicators as specified by OEM(g) Spring charging motor 0f 230V, AC(h) Auxiliary relay for transformer protection haaving buchholz alarm, Oil Temp alarm & Wdg Temp alram for Transformer feeder only(j) Relay setting after commissioning of VCB according to load/fault condition with secondary injection.(k) Provn of space heater and thermostat for heating(l) 03 No. PT 11 KV/√3/110V/√3/110V/√3 class 1.0/3 P 50VA(m) 3 Nos CT 125-75/1-1A, class1.0/5P10: 5 VA(n) Make of vaccum interupeter, circuit breaker, panels and relays shall be same make.(o) Power pack of 230V AC , 24 DC of minimum 30 minutes backup.Note :- (i) PCC platform/plinth shall be constructed as per OEM recommandation and rate for the same shall deemed to be included in quoted rates. (ii) Pre dispatch inspection at OEM factory premises shall be carried out by rep of Accepting Officer. The cost for the same is deemed to be included in quoted rates. 154 M&L for MS cross arm, bracing, supports, clamps and back plates fabricated from structural steel sections including MS nuts. Bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including applying two coats of aluminium paint over one coat of red oxide zinc chrome primer all as specified and directed 155 M&L for Aluminium Conductor Steel Reinforced (ACSR) (sizes as ordered) and fixing on Electric Poles with binding to Insulators with Aluminium Binding Wire as in OH Conductors including Stringing, Tightening, complete all as specified and directed 156 Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 240 sq mm, complete all as specified and directed. 157 Disconnecting and shifting of transformer of capacity 63 KVA with 33/0.433 KV bus bar form existing location to near by location by mechanically and reconnect the same, complete all as specified and directed. 158 Supply and fixing armoured copper control cable of 4 Sqmm, 4core for 33kV and 11kV VCB Circuit wiring with transformer complete all as specified all as specified and directed. 159 Supply and fixing armoured copper control cable of 2.5 Sqmm 10 core for 33KV and 11KV VCB Circuit wiring with transformer, complete all as specified and directed. 160 Supply and install steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP - 55 (11.0 metres long) including applying two coats of black bituminous paint internally and externally upto planting depth and applying two coats of aluminium paint over a coat of red oxide primer, externally from top of coping complete all as specified and as directed. (Note :- Excavation, PCC foundation and coping shall be measured and paid separately.) 161 Disconnecting and shifting of control panel form existing location to near by location, complete all as specified and as directed. 162 Supply and fixing cable jointing kit for 11 KV grade cable for indoor termination, cold shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 240 sqmm, complete all as specified and directed. 163 Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination, cold shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 240 sqmm, complete all as specified and directed 164 Supply and layinggravel 63 mm, complete all as specified and directed. 165 Supply and fixing post insulators for 33 KV, complete all as specified and directed. 166 Supply and fixing pin insulators for 33 KV , complete all as specified and directed. 167 Supply and fixing disc insulators for 33 KV, complete all as specified and directed. 168 M&L earthing complete with copper earth plate electrode 600mmx600mmx3.15mm thick,thick burried directly in ground vertically to a depth not less than 3.0 mtr deep below GL with top edge of the plate not less than 2.5 mtr below normal GL and connected to earth plate . Earth plate surrounded by 15 cm thick packed layers of charcoal dust and common saltupto 1.5 meter depth all around the earth plate and connected to earth leadof copper strip 20x3.15 mm by means of bolts, nuts, check nuts and washers of GI or steel and thimbles and other end of the earth wire connected to DB and protected by galvanized iron or steel pipe light grade 40 mm bore and water pipe 20mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of2009 and also including making test point for testing of earthingmade out ofgun metal or phosphorous bronge size 75x75x25 mm complete .Note : 1. RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmmin lieu of CI cover.2. Charcoal dust and commonsaltupto 1.5 meter depth shall be filled in layers of 15 centimeters all around the earth plate. 3.On testing after completion of earthing if desired earth resistance is not achieved , the earthing will be redone at no extra cost to obtain the desired earth values.(3) The cost ofGI earth lead & G Ipipe of 7.50 mtr length for protection of GI wire and excavation work for pit shalldeemed to be included in this item.Note:- Earthing test will be carried out and if desired result item not achieved the earthing will be redone to achieve desired result without any extra payment. 169 Supply and fixing copper strip of size 20x3mm, complete all as specified and directed. 170 M&L Sand Cushioning (dry) in Trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed.(NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be Measured and Paid for). 171 M & L for Cement concrete in foundations, filling and mass concrete PCC 1:5:10 type E2 (40mm graded), complete all as specified and directed. 172 Supply and Fixing of MCB TPN40 Amps, 415 Volts, 50 Hz with 10 KA C curve complete with connection testing and commissioning, complete all as specified & directed. 173 M&L for HDPE Double wall corrugated duct pipe of size 77mm OD and 63mm ID for cable protection laid in trenches complete all as specified and directed. 174 Supply and laying un-reinforced precast cement concrete cable covers, class HV, flat, type-1 of size 300mm x 180mm x 40mm in trenches for cable protection, embossed with ELECTRIC on the top surface complete all as specified and as directed. 175 Supply and fixing electric water heater storage type steel body with MS inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, PVC hot and cold, plug top etc. complete all as specified and directed. 176 Supplying and laying of CPVC pipes 16 mm dia SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all asspecified and directed. 177 Supply and fixing of 15mm bore bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed. 178 Supply and fixing of 15mm bore stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed. 179 M&L for Point wiring with 4.0 Sqmm (36/0.30mm)PVC insulated andunsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FRLS type drawn through and including PVC concealed conduit (ISI marked) of adequate size and its accessories with sunk cast iron/pressed steel terminal boxes of size 1.6mm thick, with 3mm thickplastic laminated sheet cover of adequate size for AC point wiring and Geyser point wiring incl 4.0 Sqmm (nominalarea) copper conductor cable (multistrand), FRLS type, PVC insulated and unsheathed with colour code earth wire connected to common earth dolly at one end and metalic bodies of AC point and Geyser point at other end complete as per site requirement and all as specified & directed.Note:-Unit rate include for cutting chases for conduits and sinking for boxes andmaking good to wall, floors etc. 180 Supply and fixing sheet metal encloures with plug socket single pole and neutal with two pin and earth plug and with one MCB of 20 Amps (SP), for AC point and Geyser point, complete all as specified and directed. 181 Supply and Fixing MCB SP 20 Amp rating 240V, 10KA C curve for AC point and Geyser pointcomplete with connection testing and commissioning, complete all as specified & directed. 182 Supply and fixing 4 ways TP&N distribution board sheet metal enlosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCBs 415 volts, 200 Amp rated bus bar with front openable cover suitable for, complete all as specified & directed. 183 Supply and Fixing of MCB TPN32 Amps, 415 Volts, 50 Hz with 10 KA C curve complete with connection testing and commissioning, complete all as specified & directed. 184 Material & Labour in replacement of Earthing complete withgalvanised steel earth plate electrode 60cmx60cmx6 mm thickness burried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to and incl galvanised earth lead wire of 4.00mm dia by means of nuts & bolts, check nuts and washers of galvanised incl PCC pit of 1:2:4 type B-1, cover reinforced with XPMweightnot less than 4 Kg/Sqm and 6mm dia bar handle, earth pit angle iron frame of size 25mm x 25mm,excavation and earth work in anytype of soil, charcoal dust, salt, light grade GI watering pipe 20mm dia with funnel and wire -mesh and medium grade GI protection pipe of 15mm bore from top edge of earth plate upto main distribution board complete allto as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected main switch board all as specified and testing on completion. 185 SCHEDULE OF CREDITNote :- Amount of Rs. 3,68,536.20 indicated in Tender Documents as Schedule of Credit shall be deducted from the total quoted amount of BOQ.
Contract Date: Feb 10, 2026 Contract Value : 4.02 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
West Bengal View Result →
39.
Public Administrative Department #9512351 AOC
15Th Finance Commission (Tied Grant Iind Installment) In Vadakku Valliyur Special Grade Town Panchayat Errection Of Liquid Based Chlorinator In Vadakku Valliyur Town Panchayat , Supply ,Erection , Testing And Commissioning Of Liquid Bassed Chlorine Dosing System For Water Supply Under Following Specifications. , Preparation Tank & Storage Tank Make: Ma Tech Type:Cylindrical Polyethylene Chemical Storage Tank Size:(Id X Height X Thk) Mm : Std. Usablecapacity : 1000 Ltrs. Preparation & Storage Liquid/Solution To Be Handled: Sodiumhypochloritesolution (Bleaching Liquid). Material Of Construction: Pp/Lldpe. Design Pressure : Atm+ Full Of Liquid Testing: Leakage Test: Water Fill Up Quantity : 02 Nos. , Dosing Pump/Transfer Pump Make: Ma Tech / Milton Roy / Xeeed Pump Model : Mmdp-1 Type : Mechanical Diaphragm Type Offered Capacity : 0-75 Lph Spm/Ratio: 100/15:1 Diaphragm: Ptfe Flow Control: Manually Turn Down Ratio: 10:01 Pump Standard : Mfgstd Efficiency/Accuracy : 97%/+_3% Suction: Flanged Type Discharge Pressure : 10.0 Kg/Cm2 Prvset Pressure: 5.0 Kg/Cm2 Connection Suction : 15 Nb Connection Discharge: 15 Nb Material Of Wetted Parts : Pp , Pump Drive Motor Make: Cgl/Bbl Type: Squirrel Cage Induction Motoriec Zone-Ie 2. Supply System : 3Ph.Induction, Ac, 415V±10%,50Hz+_5% Mounting/Degprotection: B3(Foot Mounted) /Ip55 Noofpoles/Rpm: 4Poles/1440Rpm Insulation Class/Temprise : Class /Limited To Class Methoed Of Cooling : Tefc Applicable Standards : Is325 Rating: 0.5Hp Motor Frame Type : Asperdin/Iec34-7 Duty Class: S1:100% Continuous Operation Noise Level(Less Than): 85Db(A) At A Distance Of1mtr. Qty : 02Nos. Qty.: 02 Nos. [1W+ 1S] , Motor-Pump Shaft Coupling Make : Rathi Couplings/Equivalent Type: Love Joy/Suitable Flexible Coupling Qty : 02 Nos. , Fitting Make : Reputed & Approved Iso-9000 Certified Supplier Type: 15Nb(Sw) Material Of Construction: Pp , Flanges (Asperansi16.5B) Size : 15Nbswrf#150 Material Of Construction: Pp/Upvc Inlet Terminal Flanges /Tank Flanges: 15Nbswrf#150 Outlet Terminal Flanges/ Companion Flanges: 15Nbswrf#150 Qty : Actualaspersiterequirement , Pulsation Dampner Make : Ma Tech Type : Volume Bottle Type Capacity : 1.5 Ltr. Moc : Pp/Upvc Qty : 01 No. , Pressure Gauge With Isolation Valve Make : Waree/Wika/Std Type : Bound On Sensing Type Mounting : Direct Bottom Dial Size : 100Mm Moc : Ss Accuracy : 1.60 % Range : 0–14 Kg/Cm2 Qty : As Per Site Requirement , Nrv Make : Ma Tech Type : Lift Check Type End Connection : 15Nbsw Moc : Pp/Upvc Qty : As Per Site Requirement , Prv Make : Ma Tech Type : Spring Loaded Connection : 15Nb300# Prv Set Pressure : 5.0Kg/Cm2 Moc : Pp/Upvc Qty : As Per Site Requirement , Strainer Make : Ma Tech Flitration Rating : 40Mesh Size : 15 Nb Moc : Pp/Upvc Qty : As Per Site Requirement , Level Guage Make : Ma Tech Type : Transparent Tubular Type Moc : Pp End Connection : 15Nb 150# Flanged Qty : As Per Site Requirement , Hoses : Braidedhosesuitableforpp / Pvc / Upvctubing Connectors Standardreputedbrand. Qty : As Per Site Requirement , Ball Valve Make: Astral/Finolex/Std Type: Ball Valve For Suction & Discharge Material Of Construction: Pp/Upvc End Connection: Sw Size : 15Nbsw#150 Qty : As Per Site Requirement , Piping With In The Skid Size/Rating Of Pipe: 15Nb Seamless Sch40/80 Suction Moc: Pp/Upvc Discharge Moc: Pp/Upvc , Gaskets Material Of Construction:Spiral Wound Gasket Scouter Inners Qty : Actual Aspersiterequirement , Fastners Make : Standard Material Of Construction: Ms Galvanised Qty : Actual Aspersiterequirement , Skid/Base Frame Supplyand Installationofmsframedkiosk (Shed)Ofsize 10 X 10Madeup Ofmsanglesnotlessthan32 X 32 X 6Mmformainframe,25 X 25 X 6Mm Forsubframesand Necessaryfastenerscoveredwithmadrassheet And Covered Withwindowsallsidesforventilation Purpose Anddoorwith 1/4Of Openwith Weld Messand3/4Coveredbymadrassheetincludingnecessaryelectricalwiringforlightsandplugpointsandasdirectedbythedepartmentengineers. A Common Base Frame For Tank, Pump And Lifting Lugs, Supports Shall Be Provided To And Above Scope Of Supply. Stool For Pump : Pump Shall Rest Not Less Than 300Mm Foundation Bolt : M-12X150mm Material Of Construction: Cs(Is:2062) Primer/Zinc Rich Epoxy Finish/High Built Epoxy : Frame Shall Be Painted With 2 Coats Of Epoxy Primer And 2 Coats Of Epoxy Paint, Colour – Bluest. Agitator With Control Panel Set : 0.5 Hp- 01 No , Starter : Fullyautomaticpanelstarterwithstandardconnectors,Mcbsindicationlampsselectorswitch,Automanualswitch,Singlephasecumphasereversalpreventerdryrunpreventerand Allnecessarywiringandstd. Specialsasperstd. , Sensor : Standard Flowsensorhavingsensingwithss 316Springactuatedtong,Outermsbodyforauto Operation. , Frpmoldeddryrunsensor : Frpmoldeddryrunsensorhavingmagneticsensorof5 Voltoperatedswitchwith3 Corex 1.5 Sq.Mm Flexiblepvcsheathedinsulatedcoppercableofabove5 Meterlengthfixedonthechlorinetanktosense Todry Run Level. , Chlorineliquid : Sodiumhypochloriteliquidsolution(Bleachingliquid)Concentrationpower4 To6 % (Grade - I)Is 11673 -1992Fordrinkingwaterchlorinationusagetometeringpumpsetsofinitialfillingforcontinuousandproperrunningofchlorinesystemstoaquantityof 2000Ltrs. As Initial Filling With The Scope Of This Work.
Contract Date: Feb 10, 2026 Contract Value : 7.75 Lakh
Local Bodies No of Bidders 2
40.
Housing Urban and Rular Development #9502542 Technical Bid
Tender For Electrical Work At Thdc Singrauli . - INTERNAL WIRING 2 Point wiring in PVC conduit, with modular type switch :- 3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 4 Group C 5 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 6 Group C 7 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 8 Power plug wiring in PVC conduit (2 x 4 Sq.Mm.) :- 9 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 10 Circuit / Sub main wiring in PVC conduit :- 11 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 12 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. 13 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. 14 2 x 10 sq.mm. + 1 x 6 sq.mm. Earth wire 15 4 x 10 sq.mm. + 2 x 6 sq.mm. Earth wire 16 S/F light plug point Modular Type Accessories :- 17 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 18 S/F power plug point modular Type Accessories :- 19 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 20 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. 21 DISTRIBUTION BOARDS & MCBs 22 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as Required. 23 Single pole 24 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 25 Supplying and Fixing Following way, Horizontal Type Three Pole and Neutral, Sheet Steel, MCB Distribution Board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 26 6 Way (4 + 18), Double Door 27 8 Way (4 + 24), Double Door 28 Supplying and fixing following way, Single Pole and Neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 29 8 way , Double door 30 12 way , Double door 31 S/F DP MCB Isolator 32 Supplying and fixing following Rating, Double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as Required. 33 40 Amps 34 S/F 4P MCB Isolator 35 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as Required. 36 63 Amps 37 S/F DP (RCCB) 38 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as Required. 39 40 Amps 40 TELEPHONE, TELEVISION & DATA SYSTEM (socket,wiring & conduting only) 41 S/F MODULAR BOXES, BASE & COVER PLATE :- 42 Supplying and Fixing Following Size/ Modules, GI Box Alongwith Modular Base & Cover Plate for Modular Switches in Recess etc. as Required. 43 1 or 2 Module (75 mm x 75 mm) 44 S/F MODULAR TYPE SWITCH / SOCKET :- 45 Supplying and Fixing Following Modular Switch/ Socket on The Existing Modular plate & Switch Box including connections But Excluding Modular Plate etc. as required. 46 Telephone Socket outlet. 47 TV Antenna socket outlet. 48 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 49 25 mm. 50 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, Unarmored Telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 51 2 Pair 52 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 53 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 54 1 run of cable 55 LIGHTINGFIXTURESANDFANS 56 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 57 Installation, testing and commissioning of pre-wired, fluorescent fitting /compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as Required. 58 Installation of Exhaust fan in the existing opening, including making good the damage, Connection, Testing, Commissioning etc. as Required. 59 Upto 450 mm sweep 60 Fixing Louvers / Shutters for Exhaust Fan: 61 Extra for Fixing the Louvers/ Shutters Complete with Frame for a Exhaust Fan of all sizes. 62 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing 63 CABLE & ACCESSORIES 64 LT CABLE LAYING 65 Laying of One Number PVC Insulated And PVC Sheathed / XLPE Power Cable of 1.1 kV Grade of Following Size Direct in Ground Including Excavation, Sand Cushioning, Protective Covering and Refilling the Trench etc. as required. 66 Upto 35 sq. mm 67 Above 35 sq. mm and upto 95 sq. mm 68 Above 95 sq. mm and upto 185 sq. mm 69 Above 185 sq. mm and upto 400 sq. mm 70 LT CABLE JOINTING & END TERMINATION 71 Supplying and Making End Termination With Brass Compression Gland and Aluminium lugs for Following Size of PVC Insulated and PVC Sheathed / XLPE Aluminium Conductor Cable of 1.1 kV Grade as Required. 72 3½ X 25 sq. mm (28mm) 73 3½ X 35 sq. mm (32mm) 74 3½ X 50 sq. mm (35mm) 75 3½ X 95 sq. mm (45mm) 76 3½ X 120 sq. mm (45mm) 77 3½ X 150 sq. mm (50mm) 78 3½ X 185 sq. mm (57mm) 79 3½ X 240 sq. mm (62mm) 80 MISCELLANEOUS ITEMS 81 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 82 EARTHING 83 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. 84 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.. (NEUTRAL EARTHING) 85 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 86 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 87 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 88 11KV HT Board, 250 KVA Transformer, 200 KVA DG Set, HT Cable & Accessories 89 H V CABLE LAYING 90 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 91 Above 120 sq. mm and upto 400 sq. mm 92 Supply and making Indoor cable end jointing with cast resin compund, including lugs and other jointing materials for following size of 3 core, XLPE aluminium conductor cable of 11KV grade as required. 93 3 C x 240 Sq.mm 94 Supply and making Outdoor cable end jointing with cast resin compund, including lugs and other jointing materials for following size of 3 core, XLPE aluminium conductor cable of 11KV grade as required. 95 3 C x 240 Sq.mm 96 Supply and Making Straight Through Cable Jointing With Cast Resin Compund, Including Ferrule & Other Jointing Materials for Following Size of 3 core, XLPE Aluminium conductor cable of 11KV grade as required. 97 3 C x 240 Sq.mm 98 RCC Hume pipes 99 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 100 250 mm dia 101 300 mm dia 102 100 mm dia 103 Manholes 104 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design. 105 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 106 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 107 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 108 HDPE PIPES 109 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 110 200 mm dia (OD-200 mm & ID-175 mm nominal) 111 CABLE TRAYS 112 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. (Cable Tray Bends as per Requirement) 113 150 mm width X 50 mm depth X 1.6 mm thickness 114 300 mm width X 50 mm depth X 1.6 mm thickness 115 450 mm width X 50 mm depth X 2.0 mm thickness 116 600 mm width X 50 mm depth X 2.0 mm thickness 117 EXTERNAL LIGHTING 118 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. 119 Above 4.5 metre and upto 6.5 metre 120 Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape , Hole Seeling to be done complete as required. 121 32 mm dia 122 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering. 123 Upto 35 sq. mm 124 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. 125 Upto 35 sq. mm 126 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 127 3 core 2.5 sq.mm (for6/4 Mtr Poles) 128 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 129 63 mm dia (OD-63 mm & ID-51 mm nominal) 130 TELEPHONE, TELEVISION & DATA SYSTEM (socket,wiring & conduting only) 131 Supplying & Fixing Modular Type Computer jack RJ 45 ISI mark 1 Module on existing Mounting plate and box Complete with all accessories as required. 132 Light Fixtures and Fans 133 Supply of 40W LED Recessed Light Fixture Aesthetically designed 2x2 LED Flat panel light which provides soft-light and glare free symmetrical illumination complete with all accessories as required. 134 Supply of Surface Mounted Energy Efficient, LED Luminaires 12W LED DOWN LIGHT (Round/Square) Sutaible for 220v Single Phase Supply complete with driver circuit including making connections etc as required. 135 Supply of Recess Mounted Energy Efficient, LED Luminaires 12W LED DOWN LIGHT (Round/Square) Sutaible for 220v Single Phase Supply complete with driver circuit including making connections etc as required. 136 Supply of Recess Mounted Energy Efficient, LED Luminaires18W LED DOWN LIGHT (Round/Square) Sutaible for 220v Single Phase Supply complete with driver circuit including making connections etc as required. 137 Supply, of Linear & Compact 10W Mirror Light with Decorative Grey Caps, Polycarbonate Body & Ribbed Opal Diffuser. 138 Supply of LED LuminairesBATTEN20W LED Tube Light of Box Type Prewired Indoor Luminairewith Energy Efficient Electronic Ballast, with End Caps Complete as Required. 139 Supply of Bulk Head Luminaire, heat resistant Glass cover suitable for 10W to 15W LED complete as Required. 140 Supply of Following sweep exhaust fan with guard suitable operation on single phase 230 V, 50Hz. AC Supply, with lowers /shutters in the existing opening. 141 300 mm Sweep 900 rpm 142 Supply & Fixing of 400mm Wall Mounted Fan with all accesseries as required complete for installation. 143 DISTRIBUTION PANELS 144 MAIN LT PANEL 145 NOTE:- MCCBs Wherever Specified shall have Rotary Handle. 146 Suppy , installation, testing, Design, manufacture, supply inspection, handling, assembling, affecting proper connections, testing and commissioningof2mm CRCA sheet steel fabricated cubical type Main L.T. Panel (Totally Type Test Assembled - TTA) floor mounting, dust & vermin proof, front operatedconstruction, enclosure class - IP 52,As per IEC 61439 after proper treatment with 9 tank process with top/bottomremovable gland plates, as required, double compression type cableglands,earth bus, hinged and lockable doorsto achieve dust and vermin proofcomplete with all inter connectionssmall wiring by min. 2.5 sq. mm. FRLS copper wires, ckt labels etc.The panel feeders shall be suitable for terminating suitable nos. 3.5 / 4 core armoured aluminium cable as required. Panel Should Be Internal Arc tested at 50ka for .3 sec as per IEC61641. 147 (Under no case temperature of main LT panel shall be more at any point of the panel. To avoid heating necessary exhaust fans shall have to be provided along with top louvers). 148 Degree of protection IP-42 149 The internal control wiring shall fuse less. All control wiring and metering protection shall be by MCBs. 150 Colour: Siemens Gray Powder Coated or as per approved shade. 151 INCOMER 1 FROM 250 KVA OUTDOOR TRANSFORMER 152 1 Nos. 400 amps four pole MCCB of fault breaking capacity 50 KA (Ics=Icu)fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicator and frame earthing contact ,confiming to IS 13947-21993 as amended upto date complete with following Accessories. 153 1 set of 3 CTs of ratio 400/5A, Class 1.0 accuracy 15 VA burden for APFCR. 154 Independent manual spring closing mechanism - 1 No. 155 Microprocessor release (EMI and EMC certified) for over current, earth fault and short circuit protection - 1Set . 156 Multifunction meter with selector switch with suitable CTs and back up MCBs. 157 3Nos. Phase indicatingLED lamps with 2 Amp backup MCB, breaker ON/OFF/Trip indication light with 2A MCB , test terminal block set, MCB , circuits as per standatd practice , auxiallry contact for positive interlocking of the breakers as required. 158 Shunt trip coil 220 Volt AC. 159 INCOMER FROM DG SET (200 KVA) - 1 Nos 160 1 Nos. 400 amps four pole MCCB of fault breaking capacity 50 KA (Ics=Icu)fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicator and frame earthing contact ,confiming to IS 13947-21993 as amended upto date complete with following Accessories . 161 1 set of 3 CTs of ratio 400/5A, Class 1.0 162 Independent manual spring closing mechanism - 1 No. 163 Microprocessor release (EMI and EMC certified) for over current, earth fault and short circuit protection- 1Set . 164 Multifunction meter with selector switch with suitable CTs and back up MCBs. 165 Protection releaseswith LSIG and Over voltage ,under voltage,Reverse power protection Relay & Metering & Accessories for each D G set incomers 166 3 Nos. Phase indicatingLED lamps with 2 Amp backup MCB, breaker ON/OFF/Trip indication light with 2A MCB , test terminal block set, MCB , circuits as per standatd practice , auxiallry contact for positive interlocking of the breakers as required . 167 Shunt trip coil 220 Volt AC. 168 1 nos battery charger with DC voltmeter and ammeter suitable for the DG sets (200 KVA) 169 INTERLOCKING 170 Interlocking logic electrical Interlocking betweenincomers and bus coupler and it should have auto start and auto trip facility for Automatic Operation of The Breakers Wit Manual Over Rid Facility 171 BUS COUPLER 172 One Number 400A 50KA 4 poleMCCB as Bus Coupler with ON/OFF Indication. 173 BUS BAR 174 500 A TPN Aluminium bus bar with heat Shrink Sleeve 175 OUTGOINGs 176 All the MCCBs Shall be Equiped/Provided with all accessories & Inbuid protection releas & MCCBs Shall be Thermal Magnetic upto 250A & Above Microprocessor Based with inbuiltO/L & S/C release. 177 1 Nos. 200 AMPSTP MCCB (Capacitor Panel) 178 1 No. 125A 36KA4P MCCB. (Ground Floor Panel) 179 1 No. 125A 36KA4P MCCB. (First Floor Panel) 180 1 No. 125A 36KA4P MCCB. (UPS Panel) 181 1 No. 100A 36KA 4P MCCB (Lift Panel) 182 1 No. 100A 36KA 4P MCCB (Fire Fighting) 183 1 No. 100A 36KA 4P MCCB (Plumbing) 184 1 No. 125A 36KA4P MCCB. (External Lighting) 185 2 No. 125A 36KA4P MCCB (Spare) 186 2 No. 100A 36KA4P MCCB (Spare) 187 Other items such as 188 1 set of control wiring 189 1 Set of designation plates 190 NOTE :- Adequate Quantity of Fire Suppression system with Pneumatic gas cylinder and Heat Sensitive Pneumatic tubing to be used in panel as perthe current fire norms & SURGE PROTECTION DEVICES Type 1 ( Class B), 4 Mode, spar type suitable for 10/350µs surge,3Nos. phase to earth and 1Nos. neutral to earth with impulse Current Iimp. ≥ 50KA Per mode & In ≥ 25kA per Mode. 191 Complete Panel as Above and complete 192 AUTOMATICPOWERFACTORCORRECTIONPANEL(CAPACITOR PANEL) - 90 KVAR- INNOVATION CENTER BLOCK 193 Supplying, Installation, Testing and Commissioning of cubicle type capacitior panel suitable for 415 & 3 phase 50 HZ A.C. supply System fabricated in compartmentalised design from CRCA Sheet Steel of2 mm thick for frame work and cover, 3 mm thick for gland plates i/cpowder coating in approve shade having 500 AMP capacityTPN Aluminium bus bar DMC/SMC bus bar supprot entire pannel should have common Al. earth bar for size 50 mm x 5 mm i/c Providing & fixing following switch gear mounting there on fans,grills for propor ventillation complete with gaskets & inner connection i/c connection with existing CTS in the main CT Panel complete as reqd. The panel board shall be of dust and verm proof with degree of protection IP 42) 194 a) 200 Amps TP MCCB with Microprocessor Based release and E/F proctection with time dely(Ics=100% Icu) - 1 No. 195 b) 250A, 4 strip Tinned Aluminium busbar -1 Set 196 c) Micro processor based automatic Power factor control relay i/c power factor metre in 8 steps 197 d) Multi functional meters with suitable CTS and protection MCBS 1 set. 198 e) 3 Nos. Phase indieating right (lamp) with MCBs protection. 199 OUTGOINGS- 200 1 Set - 63 Amp TP MCB 10 KA and Capacitor duly switching contactor for 20 KVAR capacity auto mannual selector switch start/stop puch button on/off indicatting lamp with protection MCB & delay timer complete i/c 20 KVAR mixed dielectric with 7% detuned filter copper reactor type capacitor bank with inter Connection 201 7 Set - 40 Amp TP MCB 10 KA and Capacitor duly switching contactor for 10 KVAR capacity auto mannual selector switch start/stop puch button on/off indicatting lamp with protection MCB & delay timer complete i/c 10 KVAR mixed dielectric with 7% detuned filter copper reactor type capacitor bank with inter Connection 202 complete panel as above and complete 203 GROUND & FIRST FLOOR PANEL (TYPICAL) 204 SITC of cubicle LT pannel suitable for 415V, 3 phase, 4 wire 50 HZ Ac supply system, fabricated in conmpartmentalized (preferbly) design from CRCA sheet of 2mm thick for frame work and covers, 3mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having suitable Amp capacity extensible type TPN aluminium alloy bus bars of high conductivity, DMC/SMC bus bar supports, , bottom base channel of MS section not less than 50mm x 50mm x 5mm thick,entire pannel shall have a common copper earth bar 25mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AI. bus bars and control wiring with 2.5 sq.mm. FRLS PVC insulated copper conducter S/C cable, cable alleys, cable gland plates in two half. i/c providing following switch gears :- 205 INCOMER : 125 AMP 36KA FP MCCB 206 BUS BAR :160 AMP,500 Volts, 3 phase 50 HZ4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. 207 OUT GOINGS: 208 63 AMP 4P MCB Including 1 no. of Indication Lamp (DBs) - 6 209 63 AMP 4P MCB with1 no. of Indication Lamp (Spare) - 2 210 40 AMP DP MCB with1 no. of Indication Lamp (Spare) - 1 211 complete panel as above and complete 212 UPS PANEL 213 SITC of cubicle LT pannel suitable for 415V, 3 phase, 4 wire 50 HZ Ac supply system, fabricated in conmpartmentalized (preferbly) design from CRCA sheet of 2mm thick for frame work and covers, 3mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having suitable Amp capacity extensible type TPN aluminium alloy bus bars of high conductivity, DMC/SMC bus bar supports, , bottom base channel of MS section not less than 50mm x 50mm x 5mm thick,entire pannel shall have a common copper earth bar 25mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AI. bus bars and control wiring with 2.5 sq.mm. FRLS PVC insulated copper conducter S/C cable, cable alleys, cable gland plates in two half. i/c providing following switch gears :- 214 INCOMER : 160 AMP 25KA FP MCCB (Including BY Pass Switch for 50 KVA UPS) 215 BY PASS Switch for UPS 160 AMP FP- 1 no. 216 BUS BAR :200 AMP,500 Volts, 3 phase 50 HZ4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. 217 OUT GOINGS: 218 63 AMP 4P MCB Including 1 no. of Indication Lamp (DBs) - 7 219 40 AMP DP MCB Including 1 no. of Indication Lamp (DBs) - 2 220 63 AMP 4P MCB Including 1 no. of Indication Lamp - 2 221 100 AMP 4P MCCB Including 1 no. of Indication Lamp - 1 222 63 AMP 4P MCB with1 no. of Indication Lamp (Spare) - 1 223 40 AMP DP MCB with1 no. of Indication Lamp (Spare) - 2 224 complete panel as above and complete 225 LIFT PANEL 226 Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out ofCRCA sheet steel , floor mounted totally enclosed switchbaord suitable for use of 415 volts , 3 phase, 50 HZ completewith aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing Provision which connected to the nearest earth grid. 227 INCOMER :100 AMP FP MCCB 228 BUS BAR : 125 AMP, 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.8 sq mm / amp. 229 The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature. 230 OUT GOINGS: 231 1 No 63 AMP 4P MCB(Lift) 232 1 No 40 AMP DP MCB(Machine Room DB) 233 1 No 40 AMP DP MCB(Spare) 234 1 No 63 AMP 4P MCB(Spare) 235 complete panel as above and complete 236 EXTERNAL LIGHT FEEDER PILLAR 237 Design,Manufacture, Supply, Installation,Testing and CommissioningofPanelFabricated out of 16 SWG CRCA sheet steel,IP 54, wall / floor mounting type with rain canopyThe sheet steel shall undergo minimum 7 tank treatment followed by finishing powder coating of min 60 micron thickness. the board includes415 /240 V electrolitic Aluminium Bus Bar, removable gland plates, cable glands,including connection with outgoing feeders completeinall respect, Panel Should Have Double Earthing Provision Which Connected to the Nearest Earth Grid. 238 INCOMER: 239 1 no. 125A, 25KA 4P MCCB with microprocessor based releases, ON indication, 1 no. multifunction meter (showing all power parameters), with Selector Switch, Matching Cast Resin CTs. + 3 Nos 63A DP MCB For each Phase.with 3 Nos Astronomical Weekly programmabletime switch (SST- 1min) ON Phase for automaitc switching of landscape light fixtures at sun set and sun rise or twilight (auto on/ auto off and auto mode) with manual override faiclity with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site. 240 BUS BAR 241 TPN Aluminium bus bar with heat Shrink Sleeve rated for 125A. 242 OUTGOING 243 18 nos 16A DP MCB 244 2 nos 40A DP MCB 245 1 nos 40A 4P MCB (SPARE) 246 Other items such as 247 1 Set of control wiring 248 1 Set of designation plates 249 All Items complete as above 250 CABLE & ACCESSORIES 251 Supplying of Following Sizes of 1.1 KV Grade MulticoreAluminium Conductor XLPE Power Cable Insulated armoured cable conforming to IS:7098 (Part - I) or as per Relevant IS Code complete with all Amendments etcand should be NABL certified as required. 252 3.5 C X 240 Sq.mm Al. XLPE arm. 253 3.5 C X 185 Sq.mm Al. XLPE arm. 254 3.5 C X 150 Sq.mm Al. XLPE arm. 255 3.5 C X 120 Sq.mm Al. XLPE arm. 256 3.5 C X 95 Sq.mm Al. XLPE arm. 257 3.5 C X 50 Sq.mm Al. XLPE arm. 258 3.5 C X 35 Sq.mm Al. XLPE arm. 259 3.5 C X 25 Sq.mm Al. XLPE arm. 260 MISCELLANEOUS ITEMS 261 SITC of CO2 Fire Extinguishers 4.5 kg capacity complete in all respect ISI : 15683 marked. As per Safety plus extinguisher fire carbondioxide 4.5kg, duly charged, portable and complete as per defence specification (safetyplus SPEC 4.5) 262 UPS 263 UNINTERRUPTED POWER SUPPLY (UPS) - 50 KVA 264 Supply of 50 Kva Online UPS, IGBT UPS(Transformer-less Design). 265 Supply of SMF Batteries (12Volt VRLA, 120 Ah, 28 Numbersto provide 30 Min Backup in total for 50 kva UPS at 0.8PF and ECV=1.7V. 266 Fully rated Inbuilt static switch at the inverter output and 100% rated Inbuilt static switch at the static bypass line integrated in UPS module. 267 Supply of Local Accessories (like Cabling Between UPS and the Battery onsidering Cable Routing ,Battery Interlinks , Battery Rack etc). 268 Backfeed protection at Mains & Bypass (Inbuilt / External). 269 Installation and Commissioning of 50 kVA UPS, Battery and Accessories. 270 Supply , installation , testing and commissioning 160A FP MCCB of25KA breaking Capacity in metal sheet enclosure with ON/OFF, TYB Indication lamps for Incoming of UPSComplete in All Respect as Required. 271 SUB STATION - 11KV HT BOARD, 250 KVA TRANSFORMER, 200 KVA DG SET, HT CABLE & ACCESSORIES 272 11KV SINGLE VCB PANEL BOARD 273 11KV SINGLE PANEL HT VCB (Indoor Type) - ONE INCOMERS CUM OUTGOING 274 Design, Manufacture and Supply of 1 Panel, 11 kV HT VCB Switch Board with Following Accessories : 275 Incoming Cum Outgoing 276 Indoor Type - 630A, 11kV, 350MVA for 3 Sec., TP, Horizontally isolated, horizontally drawout type, motorised spring charged, closing mechanism, motor voltage 230V AC, shunt tripping & Closing coil Voltage 24V DC, Electrically Operated, Trip Free, Dust & Vermin Proof, Vacuum Circuit Breaker (VCB) With Mechanical & Electrical OFF/ON Indicators & Provided with Following -1 No. 277 CT chamber with double wound single phase, cast resin CT, 15VA burden with core-1 for metering (CL-1) and core-2 for protection (CL-5P10) and of 60/5/5A ratio - 3Nos. 278 IDMT relay with 3 elements for over current (50-200%) and 1 element for earth fault protection(10-40%). - 1 Set 279 Anti Pumping Relay - 1 Set. 280 Master Trip Relay - 1 Set. 281 Trip circuit supervision relay - 1 Set. 282 Potential Transformers, 3 Phase, 3 Limb,Drawout Type, Resin Cast 11000/(Root 3)/110/(Root 3) Ratio Class 1 Accuracy, 100 VA Burden, with HV fuse on primary side and MCB/ MPCB on secondary side. - 1 Set 283 6 Windows Annunciator with Hooter - 1 Set 284 1 Window for over current trip - 1 Set 285 1 Window for earth fault trip - 1 Set 286 1 Window for master trip relay - 1 Set 287 1 Window for Emergency Stop Push Button - 1 Set 288 2 Windows Spare - 1 Set 289 Digital Ammeter with inbuilt selector switch - 1 Set 290 Digital Voltmeter with inbuilt selector switch - 1 Set 291 A set of breaker ON/OFF/Trip/DC control supply healthy/Trip circuit healthy/ Spring Charged VCB in test / VCB in service & R,Y,B phase indication lamps. - 1 Set 292 Emergency stop push button -1 Set 293 Limit switches with 6 NO/ 6 NC breaker auxiliary contacts - 1 Set 294 Control:- T-N-C (Trip, Neutral, Close) breaker control switch with indication arrangement. - 1 Set 295 All control wiring with protection & test terminal block as required. - 1 Set 296 Space heater with thermostat for moisture absorption. - 1 Set 297 Suitable for connection to 3C x 240 sq.mm. Cross linked polythelene(XLPE) 11kV cables or as called for. - 1 Set 298 Cable box for 3C x 240 sq.mm 11kV XLPE Al. conductor cable. - 1 Set 299 HT Danger Plate - 2 Set 300 Incoming as described above. 1 Sets 301 Powerpack as Required to Be Included (220V/24V DC), 7AH Battery for Each Breaker Module. 302 SINGLE PANEL 11KV HT VCB PANEL AS DESCRIBED ABOVE 303 11KV TRANSFORMER(11 KV /0.433 KV) (250 KVA) 304 11KV TRANSFORMER(11 KV /433 V) (250 KVA) 305 Supply Installtion, Testing and commissioning of outdoorOil cooled Outdoor Type Transformer11 KV/433 Volt Rating 3 phase, Double Wound with copper Winding.(as per IS : 1180 (part 1) : 2014Level 2 (AMENDMENT 4)/ Equivalent IEC Standard , OLTCin Steps (+10% to -10% @ 1.25%), Insulation Class : Class A , Temperature Rise : 40 Deg.c in Oil , 45 deg.c by Resistance, 50 deg.c by Ambient , Dyn 11 Vector Group and other Standard Accessories as Required Including Followings : 306 PLEASE NOTE THE TRASNFOREMR SHALL BE IN COMPLINACE WITH NEW REGUALTION IS 1180 or Equivalent IEC Standard FOR LOSSES AND EFFICIENCY and ammended upto date 307 Civil work shall be paid extra as per actual. 308 Cable Termination box with disconnecting facility for 11 KV 3C-240 sq mm XLPE cable at 11 KV side 309 ON Load Tap Changer on HV side+10% to -10% @ 1.25%. 310 Standard Fittings , Accessories /Spares :- 311 Rating and Terminal Marking Plate - 1 312 Earthing Terminals - 2 313 Lifting Lugs - 2 314 Drain Valve with Blanking Plate - 1 315 Filter Valve with Blanking Plate - 1 316 Conservator - 1 317 Conservator Oil Filling Hole With Cap - 1 318 Oil Level Indicator with Min. Marking - 1 319 Dehydrating Breather - 1 320 Conservator Drain Plug - 1 321 Air Release Device - 1 322 Pressure Relief Valve - 1 323 Thermometer Pocket - 1 324 Rollers uni directional - 4 325 Radiators Detachable - 4 326 HV Cable Box- 1 327 LT Cable Box - 1 328 Seperate Neutral Terminal - 1 329 ON Load Tap Changer - 1 330 OTI with alarm and trip contacts 331 Buchholz relay with alarm & trip contact 332 Current Transformer 333 Radiator Valve 334 Marshalling Box 335 WTI with alarm & trip contact 336 WTI Pocket 337 Drain Valve with Blanking Plate (OLTC) 338 Filter Valve with Blanking Plate (OLTC) 339 OLTC Surge Relay 340 RTCC Indoor 341 AVR 342 250 KVA (11/433V) AS DESCRIBE ABOVE 343 DIESEL GENERATOR SET - 200 KVA DG SET :- 344 200 KVA DG SET 345 Supply, intastallation, Testing & Commissioning of200 KVA Capacity Radiator cooled DG Set with Suitable StandardAMF Panel & suitable capacity engine directly coupled withalternator for 415 volt, 3 phase, 50 Hz, 4 wire, Generation system complete with accessories, Fuel Oil Tank & Control Panel etc as Required and sound proof acquastic enclosurefor the DG SET (75 db @ 1m) , including supply,fixing of antivibration pads suitable for 200 KVA DG Set as per standards of Engine manufacture, provision of conrol cablefrom engine to control panelto engine. Provision of pipe fuel pipe line of suitable size from fuel tank to engine and over flow pipe engineto fuel tank complete gatevalve and fitting leader maker etc. Supply , Intallation of starting batteries of suitableAH as recommended by manufacterer Heavy duty complete as required at site complete with stand and battery charger residentials silencer sutaible for diesel engine exhaust pipe line complete complete flange, bend, flexible pipe all as required and as directed by Engineer Incharge. 346 Diesel Engine (CPCB-4 NORMS COMPLANT) 4 Stroke, Radiator Cooled, Diesel Engine Model Developing Output Prime 160 KW Having Following Arrangement :- 347 Flywheel With Starter Ring for Generating Set 348 Air Filter , Lube Oil Cooler Assembly with Accessories. 349 Exhaust Air Manifold 350 Exhaust Bellow 351 Fuel Fiter 352 Diesel engine pre heating arrangement 353 Lube Oil Filter 354 Exhaust Gas Turbo Charger with After Coller 355 Day Tank For fuel with Markings 356 ECP Panel mounted on a Separate Frame. 357 Radiator with Pusher Type Fan, With Fan Guard, Coolant Pump. 358 12V Electrical Starting System with Starter Motor and Battery Charging Alternator. 359 Engine Mounting Supports 360 ALTERNATOR Rated at 200 KVA, 415 Volts, 3 Phase, 4 Wire, 0.8 P.F (lag), 50HZ, 1500 RPM, IN Accordance with IS 4722 /IEC 60034 as per following Specification. 361 Rating: Suitable for an over-load of 10% for 1 hour in every 12 hours operation. 362 Voltage Regulation: Provided with Fast Response Thyristor Type Electronic automatic voltage regulator, which holds output voltage within desired limits. (+/- 1%). 363 Excitation: Self Excited - Self Regulated. 364 Alternator Loading: Suitable for Taking Rated load Immediately After Machine Reaches Rated Voltage and Speed. 365 Vibration: Suitable for Direct Coupling with Engine and Mounted on Common M.S. Channel Base Frame. 366 Enclosure: Screen protected drip proof enclosure with IP – 23 degree of protection. 367 Cooling: Air Cooled type with radial fan mounted on Rotor. 368 Winding and Insulation: Insulation class H as defined in IEC – 60034-1 369 ACCESSORIES :- 370 MS Base Frame Suitable for Mounting of the Offered Engine and Alternator. 371 Day Fuel Tank of Standard Capacity as per Rating Complete Fuel Gauge, Inlet/Outlet Connections, Drains Plug, Etc. 372 Residential Silencer (1.5 Meter with 750 mm diaApprox) Including Insulation of Silencer. 373 2 Nos 12 Volts DC Battery of Suitable Capacity with Leads. 374 1 Set of AVM Pads Fitted in Base Frame. 375 TOTAL FOR 200 KVA DG SET 376 Supply of H.T. Cable 377 Supply & Testing of following 11 KV (E) grade multicore Aluminium conductor XLPE insulated cable, insulation screening withextruded semi conducting compound in combination with copper tape armoured cores laid up, inner sheath of PVC tape, galvanised steel flat strip armoured and overall PVC sheathed cable conforming to IS: 7098 (Part - II) and complete with all latest amendments etc. complete as required. 378 3 C x 240 Sq. mm11 KV (E) 379 Supply , Installation, Testing & Commissioning of Integrated Post Top Lantern With 40W LED Lampincluding Pole &connection with 3 x 2.5 sq.mm single core PVC insulated copper conductor cable from junction box to fixture as required. 380 Supply , Installation, Testing & Commissioning of 50 W LED withcomplete with pot optic reflector connection with 3x2.5sq.mm single core PVC insulated copper conductor cable from junction box to fixture as required. 381 Supply, Installation, Testing and Commissioning of 200x160x98 (KVPC) Polycarbonate thermoplastics enclosure - junction box with I.P - 65 Protection with Terminals &cable hinged cover of approved design complete having gasket of internally embedded & made of polyeutherene & should be weather proof, rust proof, dust proof, water proof - box shall be tested as per IEC - 60670-2/60670-22. the box shall have self threaded holes & provision for mounting din rail. with 2 Nos cable gland including supplying & fixing crimping 2 nos lugs & 1 nos 32A connector 6 way for looping the incoming & outgoing cables and also connection of the street light one 6A SP MCB Including Connection of 2x6 sqmm Cable etc as Required. 382 Supplying of 6 mtr long hot dip Galvanized octagonal Pole with top of the pole 70 mm dia (A/F) and bottom of the pole 130 mm dia (A/F) made out of 3mm sheet with MS base plate of size 200mm (NS) x 200mm (NS) x 16mm (NS) on precast RCC foundation complete with suitable size openinginside the pole with flush weather proof door with locking facility preferably with LN key having proper arrangement with Accommodating of 1 Nos. 6 Amp.,10 KA MCB & neutral link4 way connector suitable for 25 Sqmm cable complete with electrically safe including inside cable termination with thimbles i/c wiring from pole box to fitting with 3x1.5 sq.mm. FRLS PVC insulated copper conductor wire, earth connection, din channel, earth stud and other accessories pertaining to this pole (But without street light fitting) etc as reqd.including providing & laying in position suitable RCC foundation as required for 6 mtr. octagonal hot dip Galvanized Pole as per Manufacturers drawing with 1:1.5:3 concrete (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) including excavation of all kind of earth such as all type of soil/soft rock or hard rock etc. as per existing site condition i/c providing, cutting, bending and placing reinforcement & IncludingJ typefoundation bolts , anchor plate and templates in position as per manufacturer Standard and Providing PVC Pipe for Cable Entry and Exits Including Disposal of Surplus Malba / Softrock / Hardrock Stone etc.as Required. 383 Supplying of Following sizes 1100 volt grade XLPE insulated PVC sheathed aluminium conductor armoured cables as per specification in existing laid in ground including cost of digging upto required depth, 150 mm sand all around the cable, brick protection and back filling, clamped to wall with suitable clamps including saddles fixing bolts, Connection Testing and commissioning as Required. 384 2x6 sqmm 385 Supplying of Following sizes 1100 volt grade XLPE insulated PVC sheathed aluminium conductor armoured cables as per specification in existing trenches/pipes, cable trays, ducts, clamped to wall with suitable clamps including, saddles fixing bolts, connecting testing and commissioning as Required. 386 2x6 sqmm 387 Supply, Installation, Testing and Commissioning of 120w Flood Light, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light, suitable for highlighting architectural facade and general purpose lighting. 388 SOLAR POWER SYSTEM 389 Supplying, installation, testing and commissioning of Grid interactive roof top solar photo voltaic power generation system including space frame 390 (SCHEDULED ITEMS - AS PER DSR (E&M) 2022 391 (A) Supplying , installation , testing and commissioning of electric driven terrace pump suitable for automatic opeartion and consisiting of the following, complete in all respects as required:( Terrace pump) 392 (B) Horizontal type, multistage, centifugal, split casing pump of cast iron body & bronze impeller with stainless shaft, mechanical conforming to IS:1520 393 © Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 hz, AC supply with IP55 clas of protection for enclosure, horizontal foot mounted type with class-F insulation, conforming to IS-325. 394 (d)M.S fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. 395 (E)Suitbalecement concrete foundation duly plastered and with anti vibration pads. 396 Discharge : 450 liter per minute 397 Head : 35 meter 398 Providing, laying, testing & commissioningof C class heavy duty MS pipe conforming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flangers, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 399 100 mm dia 400 Providing, laying, testing & commissioning of B class medium duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc, and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 401 100mm dia 402 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type-A) with blank Gunmetal/Stainless Steel cap and chain as required: 403 Single headed Stainless steel. 404 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. 405 100 MM NB 406 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required 407 100 NB 408 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange 409 100 mm dia. 410 Supplyinig and fixing 63 mm dia , 15 mm long RRL hose pipe with 63 mm dia male and female couplings duly bound with GIwire , rivets etc.confirming to IS 636 (type-A) as required: 411 Supply, fixing first aid Hose Reel with MS costruction spray painted in post office red , conforming to IS 884 complete with the following as required 20 mm nominal internals diawater hoseThermo plastic (Textile reinforced) type -2as per IS 12585) 20 mm nominal internal dia gun metal globe valve & nozzle Drum and brackets for fixing the equipments on wall .connections from riser with 25 mm dia stop gun metalvalve & M.S . Pipe and socket.40 M 412 Supplying and fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confirming to IS 903 Suitable for instantaneous connection to interconnect hose pipe coupling as required:Stainless steel (Grade 304) 413 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 414 2 way-100 mm dia M.S. Pipe 415 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. 416 TOTAL- A(SCHEDULED ITEMS - AS PER DSR E&M 2022) 417 (NON SCHEDULED ITEMS - AS PER MARKET RATES) 418 Supply & erection of ISI marked portable fire extinguishers, confirming to IS:15683, wall mounted type, wall brackets complete in all respect as per standard item with all accessories, delivery hose & nozzle whereever required, including fixing on walls as per the directions ofEngineer-in-charge. 419 Water CO2type. 9 Lt. capacity 420 D.C.P.Type 6 kg. capacity 421 ABC dry powder Type 6 kg. capacity 422 CO2 gas type. 6.5 kg. cap. -Trolley mounted 423 Providing & fixing neoprene rubber double flangedrubber expansion joint(anti vibration bellow) of standard length as per manufacturers specifications. suitable for hydrostatic test pressure of 21 kg/sqcm including all necessary fittings i.e. rubber gasket, nuts, bolts, washers etc complete as required. 424 100 mm dia. 425 150 mm dia. 426 Providing & fixing standard carbon steel fireman axe with rubber insulated handle tested to 20000 Volts. 427 Supply, fixing, testing & commissioning of 25 mm dia inspecting and testing assembly with gun metal valve, sight glass, by pass valve and connection to the drain line as required to complete the system. 428 Providing and fixing of cast iron body 100 mm dia Draw out connection in Under ground water storage tankwith heavy class MS suction pipe of required length,foot valve, suction coupling in conformity with local regulations complete in all respects. 429 Providing and fixing weather proof standard fire hose cabinet (750 mm x 600 mm x 250 mm)outdoor typemade of not less than 16 SWG MS sheethaving glassed hinged door (5 mm thick glass) including necessary locking arrangement with handle for housing two nos.15 meter long fire hose pipes, branch pipeas required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coat of fire red colour). The cabinet shall be mounted onself standing mounted type MS Angle iron frame as required. The words FIRE HOSE to be painted on the box. 430 Providing and fixing standard fire hose cabinet door with frame (900 mm x 2000 mm ) or (suitable to fit in the duct made of not less than 16 SWG MS sheethavingglass hinged door (5 mm thick glass) including necessary locking arrangement with handle as required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coats of fire red colour). The door shall be fixed in the masonry wall or as required. The words FIRE HOSE to be painted on the box. 431 Supply, installation and testing of cylindrical type flanged pressurevessel tank, 450 mm dia, 2 m long and of 10 mm thick M.S., common for a set of fire pumpsincluding flanged connection, suitable supporting legswith MS plate of size 75x75x5 mm at the bottom and grouted in CC foundation. The air vessel tank shall be provided with air release valve, stop cock, safety valve, pressure gauge, 50 mm dia drain valve, suitable length of connecting pipe and valve from delivery header to vessel tank, suitable pressure switches to operate all pumps (1 nos each), tested to min 25 KG/cm2complete including painting with synthetic enamel paint of approved shade with all accessories as per direction of the Engineer-in-charge. (For Pump House) 432 Providing & fixing 100 mm dia dial pressure gauge including making connections with MS pipecomplete in all respects. 433 PART-A EQUIPMENT 434 OUTDOOR UNITS (HEAT PUMP TYPE) 435 Supplying,installing,testingandcommissioningofaircooled variable refrigerant volume / Flow modular typeairconditioning system with R410a refrigerant. The PCB Chamber of outdoor unit should be refrigerant cooled suitable for 415±10% 3 Phase, 50 cycles. The unit shall consist of indoor and out door units withindividual controllerasperdetailgiveninspecifications andhaving followingitems:(Theseitemsareto be giveninIndian rupeeswithcustomduites,inlandfrt,clearanceetconSitebasis) 436 Modular type outdoor units equippedwith highlyefficient 100% inverter type hermitically sealed scroll compressors, minimum two comprossors for and above 14 HP modules, with special precoated heat exchanger, low noise condenser fan housed in compact housing duly powder coated and manufacturer of compressor and outdoor unit should be same. The Unit should have automatic refrigerant charge function. The static pressure of the outdoor unit shall be more then78Patoavoidhotairrecirculation.The unitshallbeabletooperateuptoto45°Cin coolingmode.The unit shall also have feature to automatically modulate the evaporative temperature between 6 deg C to 11 deg C with respecttoloadforbettercomfortandenergy efficiency etc complete as reqd. The units should have free phase technology for countinued operation. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping .The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 of following capacitites: 437 Cost of R 410 A Gas should be inclusive 438 The outdoor unit should include all loading, unloading, transportation, power cabling/wiring from near the indoor and outdoor units respectively. 439 The outdoor unit should include all loading, unloading, transportation, power cabling/wiring,( Y/T joints which is required for ODU Zone requirement Modules) from near the indoor and outdoor units respectively. Outdoor Units-Heat Pump , Fully Gas Charged and Aluminum fins within the ODU (condensing) unit shall be coated with polysiloxane based coating. 440 The Vendor should considere the deration on ODU election as per Singroli MP Ambient conditions 441 18 HP Outdoor unit VRV/VRF Zone-01 442 16 HP Outdoor unit VRV/VRF Zone-02 443 22 HP Outdoor unit VRV/VRF Zone-03 444 26 HP Outdoor unit VRV/VRF Zone-02 445 INDOOR UNITS 446 Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ±10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree CDB and 19 Degree C WB temperature. 447 Ceiling Mounted Cassette Unit 448 300-318 CFM / 0.63-0.80 TR 449 310-335 CFM / 1.0 TR 450 600-670 CFM / 1.2-1.3 TR 451 812-830 CFM / 1.6-2.0 TR 452 850-865 CFM / 2.5-2.8 TR 453 1130-1165 CFM / 3.1-3.2 TR 454 Ceiling Mounted HSP Ductable Unit 455 1130 -1150 CFM / 3.0-3.40 TR 456 1200-1377 CFM / 3.95-4.0 TR 457 1600-2050 CFM / 4.5-5.5 TR 458 2047-2295 CFM / 6.36-7.1 TR 459 REMOTE CONTROLLERS 460 Supply, installation, tesing and commissioning of Imported Remote controllers (Corded) for operation of ductable indoor units and AHUs. 461 Touch screen controller for indoor units controller - VRV 462 Supply, installation, testing and commissioning of touch screen controller (Which is controlled 45 nos. indoor units in terms of ON/Off Status, temp. Status, Fan Speed, ODU On/Off Status etc.) with all accessories and controls. 463 REFNUTS /T/ Y-JOINTS 464 Supply, installation, tesing and commissioning of Imported fittings Y-joints insulated, distributer and headers for all Indoor units at both the ends floors layout as per layout drawings.All interconnecting joints, Y Joints withpolysiloxane based coating 465 REFRIGERANT PIPING 466 Supply, installation, testing and commissioning of Interconnectingrefrigerantpipe work with (13/ 19mm thick) cross linked closed cell Oxide Acetate Foam tubular insulation between each set ofindoor & outdoor units asper specifications, allpiping inside the room shall be properly supported with hangersandv All interconnecting Copper piping, joints, U bends withoxycoat dual barrier coating shall run incable tray. (Note: Ref. Piping Length may be review as per site routing) 467 06.35 mm with 13 mm thick cross linked closed cell Oxide Acetate Foam insulation 468 09.52 mm with 13 mm thick cross linked closed cell Oxide Acetate Foam insulation 469 12.70 mm with 13 mm thick cross linked closed cell Oxide Acetate Foam insulation 470 15.88 mm with 13 mm thick cross linked closed cell Oxide Acetate Foam insulation 471 19.05 mm with 13 mm thick cross linked closed cell Oxide Acetate Foam insulation 472 22.22 mm with 19 mm thick cross linked closed cell Oxide Acetate Foam insulation 473 28.58 mm with 19 mm thick cross linked closed cell Oxide Acetate Foam insulation 474 34.92 mm with 19 mm thick cross linked closed cell Oxide Acetate Foam insulation 475 41.30 mm with 19 mm thick cross linked closed cell Oxide Acetate Foam insulation 476 TRANSMISSION & CONTROL WIRING 477 Supply, installation, testing, termination and commissioning of control cum transimission wiring (should be shielded cable in PVC Pipe) of 2C x 1.5 Sqmm Cu between indoor unit and out door unit and indoor units and its remote controller. 478 2C x 1.5 Sqmm Cu Cable or as per Manufacturer OEM 479 Perforated GITray with hangers & supports for copper piping (250 mm wide) 480 Refrigerant-410a 481 Supply , charging & Leackage testing of refrigerant -410a in additionalcopper piping circuit. 482 CONDENSATE DRAIN PIPE 483 Supplying, fixing,testing and commissioning offollowing PVC pipes for condensate drain duly insulated with Fire rated Class O kinny foam /Nitrile Rubber & vapour barrier duly secured with adhesive tape as per specification ,cut to required length and installed with all joints , including the necessary fittings. (For all the AHU/FCU units upto the main header in the shaft dor vertical risers) 484 65mm dia 485 50mm dia 486 40mm dia 487 30mm dia 488 25 mm dia 489 TOTAL CARRIED OVER TO SUMMARY ( PART-A EQUIPMENTS) 490 PART-B VENTILATION 491 Propeller fan 492 Supply,installation,testing and commissioning of Certified Propeller fan of the following capacity of approved make and specification. Fan shall be supplied with aluminum gravity louver & bird screen and Speed Regulator. 493 200 mmdia propeller fan,with single phase motor 494 300 mmdia propeller fan,with single phase motor 495 450 mmdia propeller fan ,with single phase motor 496 Inline fan 497 Supply, installation, testing and commissioning ofCertified Circular/Rectangular swing type Inline fan with fiire retardent Canvas connection Speed Regulatorof the following capacity of approved make and specification. 498 100-300 CFM,5-7 mm SP WG with Single phase motor 499 350-400 CFM,10-12 mm SP WG with Single phase motor 500 600-800 CFM,10-12 mm SP WG with Single phase motor 501 Tube Axial Flow fans 502 SITC of Long case Tube axial flow fans, as per specifications and approved makes suitable for three phase operation respectively Normal/Smoke case. 503 SITC of AMCA Certified (For Air and Sound Performance) tube axial flow fan of different capacity as mentioned below in standard M.S.contruction. Entire fan model & AMCA Seal shall apear in techncial submittal of fan. All the fans are synthetic enamelled panited/hot dip galvanized with minimum 220 GSM Zinc Coating and complete with bird screen at inlet. The electric motor coupler shall be squirrel cage induction motor (IE-2 type) confirming to IS - 325-IP - 55 with class `F insulation.Fan efficiency should not be less than 70 %, noise level should not be more than 85 db @ 3 m distance when measured in hemisperical reverberant room conditions. Fans should be as per specification and drawings. (As per Vent. Fan Schedule ) (Makeup Air & Pressurization Fans with St. Press. of 40 mmWG/Make Up Air Fan at 30mm WG) 504 6000 CFM (For Stairwell/Liftwell Pressurization) 505 6500 CFM (For Smoke Extract,with H Class insulation) 506 AIR SIDE WORKS 507 Site Fabricated Duct - GI duct 508 Supply,Installation,balancing and commissioning of fabricated at site GSS sheet metal ducts (rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter,vanes, hangers, Gripple supportsetc.) in accordance with the approved shop drawings and specifications , and shall also confirm to the BIS specifications.The duct shall be fabricated at site for to suit pieces. 509 0.63mm (24 gauge) GSS 510 0.8 mm (22 gauge)GSS 511 Factory Fabricated Duct - GI duct 512 Supply,Installation,balancing and commissioning of factory fabricated GSS sheet metal ducts (rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter,vanes, hangers, Gripple supportsetc.) in accordance with the approved shop drawings and specifications , and shall also confirm to the BIS specifications.The duct shall be fabricated at site for to suit pieces. 513 0.63mm (24 gauge) GSS 514 0.8 mm (22 gauge)GSS 515 Supply, Fabrication, Installation and testing of Insulated Al. Flexible ducts in accordance with the approved shop floor drawings and specifications and shall also confirm to the BIS specifications. 516 200 mm Dia. 517 150 mm Dia. 518 Grilles/Diffusers 519 Supplying and fixing of Extruded aluminium supply and return air grilles/diffusers/louvres with dampers, supply air plenum etc. duly powder coated as per specifications and drawings. 520 Aluminium supply air grilles with damper. 521 Aluminium return air grilles without damper. 522 Aluminium supply air square diffuser with damper 523 Aluminium return/exhaust air square diffuser without damper. 524 Aluminium return/exhaust airValve circular/squirell diffuser without damper. 525 Fresh Air/Exhaust Air Louvers 526 Supplying and fixing ofextruded aluminium louvres with frame bird screeen , mounting arrangement etc. as per specifications and drawings. 527 Fresh Air/Exhaust Louvers 528 Supply,Installation,Testing and commissioning of doble layer canvas connection with 1/2 hr. fire ratingasper specification. 529 MECHANICAL INSULATION 530 DUCT LINE ACOUSTIC TREATMENT 531 Supply and installation of cross linked open cell Oxide Acetate( AccoIsolate) Foam Acoustic insulation on ducts having density of 30 to 60Kg/ M³ ,having K value 0.029 W/m ° K at 0°C Deg temp and temp range of-70°C to +100°C and fire rating Class O as per BS 476 Part 6 fromCBRI,Roorkee and CFC/HCFC free as per US EPA 5021 A(2014 ). • Smoke & Toxicity index of material shall be passed as per IMO MSC 307 ( 88 ) 2010 Anexx 1 Pt 2 andas per the approved specifications. 532 15mm thick Oxice Acetate Acco IsolateAcoustic open cell insulation on one side for Duct acoustic insulation 533 DUCT LINE THERMAL INSULATION 534 Supply and installation of cross linked closed cell Oxide Acetate( Thermo Isolate) Foam Thermal insulation on ducts having density 0f 30 ±3Kg/ M³ ,having K value 0.029 W/m ° K at 0°C Deg temp and temp range of-70°C to +100°C and fire rating Class O as per BS 476 Part 6 fromCBRI,Roorkee and CFC/HCFC free as per US EPA 5021 A(2014 ). • Smoke & Toxicity index of material shall be passed as per IMO MSC 307 ( 88 ) 2010 Anexx 1 Pt 2 andas per the approved specifications. 535 25 mm thick insulation oxide acetatefoam with 2 coat layer of 7 mile cloth with starbond or eql. adhesive on Exposed supply air duct 536 13 mm thick insulation oxide acetatefoam laminated with aluminium foil supply air duct 537 9mm thick insulation oxide acetatefoam laminated with aluminium foil supply air duct 538 EXPOSED ROOF INSULATION 539 Supply and installation of cross linked closed cell Oxide Acetate( Thermo Isolate) Foam Thermal insulation on ducts having density 0f 30 ±3Kg/ M³ ,having K value 0.029 W/m ° K at 0°C Deg temp and temp range of-70°C to +100°C and fire rating Class O as per BS 476 Part 6 fromCBRI,Roorkee and CFC/HCFC free as per US EPA 5021 A(2014 ). • Smoke & Toxicity index of material shall be passed as per IMO MSC 307 ( 88 ) 2010 Anexx 1 Pt 2 andas per the approved specifications. 540 19mmthick oxide acetate insulation for underceck plain 541 TOTAL CARRIED TOSUMMARY(Mechanical Insulation works) 542 ASSOCIATED ELECTRICAL WORKS 543 Therates for the distribution boards from the Breakers andinstrumentsshall also include the following : 544 Wiring forlight / Fan points with 1.5 sq. mm PVC insulatedcopper conductor1100 Volt grade strandedflexible FRLS wiresofapproved makein1.6mmthick25mmdiaMS conduitincluding costof providing & fixing saddles, hangers, supports, cutting chases and filling chases for recessed conduiting, and including the cost of providing and fixing a6 amp240Volt ModularPlatetypeswitchesof approved quality,colour, makeanddesign with mouldedcover platein zinc chromate passivated MS box and including the cost of running 1.5 sq. mm PVC insulated copper earth wire for loop earthing etc. complete 545 TPN ACB’s / MCCB’s shall mean 3 pole ACB’s / MCCB’s with adequatesize of neutral link. 546 All MCB’s shall be of minimum 10 KA breaking capacity and MCCB s shall be not lessthan 25KA 547 The breaking capacity of MCCB’s are mentioned panel wise. All MCCB’s shall be with thermalmagnetic microprocessorreleasesas per BOQand following : 548 i.MCCB rating upto 250 Amps with thermal magnetic releases. 549 ii. MCCB above 250 Amps with microprocessor releases. 550 All MCB’s used for protection ofresistiveand lightlyinductive loadshallbetype “B”characteristic and inductive(motor)loadshall be of type “C” characteristic. 551 Degree of protection for following type of distribution panel enclosureshall be as per IS:13947-1993. 552 i.IP 42 for indoor panels. 553 ii. IP 55 for ODU panel. 554 AllMCCB’sshall beprovidedwithoperatingmechanismfordoorinterlock. 555 All hinged door shall be earthedthrough2.5 sq mm tinnedbraidedcopper wire. 556 Providing cableclamps/ supportswithin distributionboardscablealley. 557 Current density of aluminium shall be 1sq mm for 1.0 Amps for ratedcurrent of bus bars. 558 Model, current capacity location and frame size of switchgear shall be writteninside of thepanel doors with paint / permanent marker asapproved shop drawings / site requirment. 559 All meter shall be digital type and all starter shall be as per Type-2 Coordination chart 560 Current Transfomer shall be resin cast. 561 All Panel Shall be BMS Compitable 562 AHU/Fan Panel 563 Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of following LT panels fabricated out of 14 guage CRCA sheet steel in cubical formationwith reinforecment of suitable size angle iron and channel T iron flats. All steel material used in the construction of panels shall be powder coated. A solid busbar shall be provided at the bottom of the panel with two connecting eyes for termination. The boards shall be suitable for 415 volts, 50 Hz, 3 phase , 4 wire supply system. All the hardware used in the fabrication of the panel shall be galvanized with zinc passivation. The panel shall be compartmentalized to accommodate one feeder in each compartment. A vertcal cable alley of suitable width shall be provided to serve on or two vertical feeder sections. Also the opening between the busbar chamber and the feeder section shall be shrouded with bakelite / hylam sheet with min.3 mm thickness. 564 The panel drawing shall be approved before taking up the fabrication and compitable BMS if in future required. (ALL AHU PANEL WITH 565 In All panel Each starter should have remote control and interlocking facilities including auto manual switch, NO/NC contacts for control and must have auto manual operation suitable to take signal from fire alarm panel for automatic operation of fan in case of fire.All smoke /vent. fan panel the starters shall have suitable facility to operate with fire sensing control modules. 566 Vent. Fan Panel- MCC -1 567 Incoming 568 1 no. 63 amp MCCB 569 Phase indicating lights with control fuses. 570 Breaker ON/OFF/TRIP indicating lights. 571 Bus Bars 572 100 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves. 573 Outgoings 574 3 nos. 6-10 A,TP MPCB(With DOL Starter) 575 The base frame shall be 75 mm x 5 mm. 576 Panel as described above and in drawings. 577 METER BOARD / SUB PANELS 578 Supplying, Installation, Testing and Commissioning of dust, damp and vermin proof free floor standing / wall mounted factory built sheet steel enclosed modular construction extendable panel, suitable for operation on 415 + 10% volts, 50 Hz AC 3 phase 4 wire system fabricated out of suitable sized square tubular section and covered with 2.0mm thick CRCA sheet, hinged doors of 2mm thick CRCA sheet, duly painted complete with aluminium bus bars, interconnection with solid copper conductor wires / aluminium strips, neutral links, earth bus etc. necessary metering protections & indications and mounted with the following as per drawing and technical specifications attached etc. complete as required. 579 ODUs Panel-01-TERRHVAC 580 Same as above item but outdoor Panel with following accessories. 581 INCOMING: 582 1 No. 200 amps, 415VTPN MCCB with overcurrent and short circuit releases, all indication, push button etc. 583 Coloured (Red, Yellow, Blue) phase indicating lamp - 1 set 584 (0 - 200 A) CT operated Ammeter with selector switch& 3 nos. CTs ratio 200/5A , 15VA burden & accuracy class of 1.0 - 1 set 585 0-500 V Voltmeter with selector switch - 1 set 586 BUSBAR: 587 250 Amp. TPN, 35 kA Al. Bus Bar 588 OUTGOINGS: 589 80A, TPN ELCB with 300mA- 3 Nos. (Incl. 1No. Spare) 590 40A, TPN ELCB with 300mA- 5 Nos. (Incl. 1No. Spare) 591 ODU Panel Described as above/As per Manufacturer ODU Configuration. 592 Spcl. Note : All Above mentionedpanel SITC as per actual GA dwgs. equipments and final config,. Of ODUs. 593 CABLING (POWER ) 594 Power Cabling and Earthing: 595 Spcl. All Cables Should be fire survival Cables (FRLS) 596 Supply, installation, testing & commisioning of LPCB approved mineral insulated copper conductor cables, construction as per BSEN 60702-1:2002 suitable for withstanding 950 deg under fire conditions as per BS 6387 CWZ and 850 deg under fire conditions on one single sample as per BSEN 50200. Cable should be manufactured with seamless copper tube and should be HFLS sheathed. (Tagging to be provided with aluminium strips on both the ends as approved). 597 3Cx10 Sqmm 598 3Cx06 Sqmm 599 3Cx04 Sqmm 600 4Cx06 Sqmm Cu 601 4Cx10 Sqmm Cu 602 Control Cabling 603 Supply, installation, testing & commisioning ofCopper conductor , PVC insulated, PVC sheathed armoured cable of 1.1 KV grade (Which is Interconnecting wiring for the fire alarm system with the AHU and the smoke dampers and AHU to Control Consol Panel). 604 8C x 1.5 Sqmm 605 Supply, installation, testing & commisioning of cable termination of above cables with copper lugs & flameproof brass compression glands on both the ends with inhibting compound etc. complete as required. 606 3Cx10 Sqmm 607 3Cx06 Sqmm 608 3Cx04 Sqmm 609 4Cx06 Sqmm Cu 610 4Cx10 Sqmm Cu 611 Supplying and installing following size of perforated G.I. cable trays, G.I. bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with suitable suspenders including G.I. bolts & nuts, painting of suspenders etc. complete as required. 612 100 mm. Width x 50mm. Depth x 1.6mm. Thickness. 613 150 mm. Width x 50mm. Depth x 1.6mm. Thickness. 614 225 mm. Width x 50mm. Depth x 1.6mm. Thickness. 615 Providing and fixing following size of G.I. strip / G.I. wire on surface or in recess for loop earthing alongwith the existing surface/ recessed conduit/ submain wiring / on cable tray/ on surface including G.I. clamps etc. complete as required. 616 6 SWG G.I. wire 617 Electrical work i.e. 618 3 Pin socket switch for Cassette, fcu, inline fan, propeller fan etc. near to the each unit. 619 Isolator Switch (Weather Proof) near to the each ODU. 620 Copper wiring /earthing from Isolator switch to M/C (chillers, pump, AHU , Fan etc.) 621 All DOL Starter Panel and Power cable for Fans/AHU 622 RCC Foundation for chiller, pumps, panels/outdoor units etc.. 623 Spcl. Note:The work includes design, supply, fabrication, erection, testing & commissioning of the complete air conditioning system with items specified above. 624 Supply Installation , Testing & Commissioning of 8 Passangers, 544 Kg. 1mps. Automatic Elevator, with VVVF and Microprocessor based Simplex Collective Selectivewith/without Provision ofattendant control. Separate Landing Push Button Box for all Landings with scrolling indicator. with provision of Attendant control, having 2 stops , 2 Openings with SS Cabin (Hair Line Finish) havingCross flow fan for Ventillation , having sleek (SS hair Line finish-PVC) and LED small Circular lighting all complete. 625 Other Features 626 Battery Operated Emergency Light And Alarm Bell 627 Call Register Signal And Vf Door Operator 628 False Ceiling In Car 629 Vandal Proof S.S. Button With S.S. Cover 630 Firemans Switch 631 Infra Red Door Screen 632 Full Car Operating Panel 633 3 Way Intercom / Press And Speak Phone 634 Push Button - Orange L E D Illumination 635 Dot Matrix Led D & P Indicators In Car & Landings -Orange Colour 636 Automatic Rescue Device 637 Minor Builders Work 638 Scaffolding 639 Floor Annunciator With Music 640 Braille Buttons 641 Sill Support 642 Lift License 643 Overload Warning Indicator With Audio Announcement 644 Pit Ladder 645 Auto Light & Fan Switch Off (Pod) 646 SUB HEAD - I: CIRCUIT CUM POINT WIRING 647 SWITCH CONTROL LIGHT POINTS 648 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 649 Group C 650 MCB CONTROL LIGHT POINTS 651 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points) 652 Primary point controlled by one MCB. 653 Same as item above but Secondary point. i.e. Points to be looped with Primary pointwith 2.5 sqmm wire and Point wiring 654 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 655 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 656 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 657 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 658 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 659 2 x 10 sq. mm + 1 x 10 sq.mm earth wire 660 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 661 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 662 Supplying and fixingsuitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required. 663 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 664 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 665 Telephone socket outlet 666 SUBHEAD -II - FITTINGS & FIXTURES 667 Supply, Installation, Testing and Commissioning of 18/20W Wall/Surface mouted 4 ft. LED 668 Supply, Installation, Testing and Commissioning of 40W LED POST TOP LANTERN 669 Supply, Installation, Testing and Commissioning of 40W LED GATE LIGHT 670 Supply, Installation, Testing and Commissioning of9W (Nominal)Wall Bracket Light 671 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 672 SUBHEAD - III - DISTRIBUTION BOARDS 673 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 674 12 way, Double door 675 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 676 Single Pole 677 Single Pole Neutral 678 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 679 40 A 680 63 A 681 Supplying and fixing following rating, double pole, (single phaseand neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 682 40 A 683 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Madhya Pradesh View Result →
41.
Health and Family Welfare #9493177 Technical Bid
The Approval Of Rates (Rate Contract) For Veterinary Equipment, Machineries Etc For Financial Year 2025-26 The Supply Of Veterinary Equipments, Machineries And Instruments Etc. For A.I., Surgical, Pathological, Laboratory And Hospital Use. For Departments Of Animal Husbandry, Government Of Uttar Pradesh For The Financial Year - 2025-26 , A.I. Kit - Artificial Insemination Gun Universal Autolocking Type With Container–02 Pcs, Insulated Cover For Keeping A.I. Gun Warmer At Required Temp-2 , A.I. Sheath Universal–200Pc, Clinical Thermometer Dual Scaleflat Body-1Pcs, Long Stem Thermometer 0-50 0 C In Plastic Case –1 Pcs., A.I. Sheath Container Plastic With One End Closed And Other With Screw Cap For 50 Sheath – 2Pcs, Straw Cutter For Cutting Strawuniform – 2 Pcs, Thawing Kidney Tray 12” Ss – 1 Pcs, Straw Tweezer Minimum 8” Straw Grooved Edges For Holding The Without Crushing Made Up Of Ss – 1Pcs, Straw Tweezer Minimum 8” Straw Grooved Edges For Holding The Without Crushing Made Up Of Ss – 1 Pcs, A.I. Apron Washable With Cotton Bidding Stitched On All Corner It Shouldprovided With Neck And Waist Ties With One Pocket On Front – 1 Pcs, A.I. Disposable Gloves 100 Pcs In A Pkt – 1 Pkt, Hand Gel With Moisturiser Containing Ethanol And Tricllosan 50 Ml.- 1 Pcs , Disposable Boot Cover Ldpe Made With Elastic – 100 Pair , Long Forceps For Holding /Lifting The Material 450 Mm. -1 Pcs , Dipstick For Measuring The Level Of Nitrogen 0-100 Folding B Type In A Sutiable Cover – 1 Pcs , Wide Mouth Flask Ss Inside An Outside 500 Ml. Capacity Screw Cap- 1 Pcs , Dial Thermometer 0-110Ocsteel Make -1 Pcs , Instant Accurate Unbreakable Thaw Monitor 35-37Oc With Different Colour Indication-01 Pcs , A.I.Gununiversal Technical Specification For Universal A.I. Gun For Bovine For 0.25Ml And 0.5Ml Straws – Type: Universal Fora.I. Gun For Mini And Medium Straws Comptibility : Suitable For 0.25Ml Straw For Split And Unsplit Sheaths Iso Certifications : Manufactured Under Iso 9001:2000 Standerds Length Of Gun : Total Length Of Gun 444-447 Mm, Length Of Gun Without Mandairn/ Stylet 436-437Mm Diameter : Internal = 3.18 Mm External = 3.62 To 3.65Mm Composition Of Gun, Adherence : Stainless Type 304H With 0.04 To 0.08% Carbon Physical Quality : Rust Proof, Even After Sterlization At High Temperature , Animal Sling, Large Animal Sling Is Composed Of 4 Legs (Approx. 6 Feet) Of 2 Inch Iron Pipes Of Length. These Pipes Are Welded On Top By Square Of 26*26 Inches Of Similar Diameter Pipe. Legs Of Two Opposite Sides Are Welded Transversely With A Similar Diameter Pipe Located At 3 Feet And 3 Inch Height From Ground. The Other Two Straight Side Are Kept Open. A 1.5 Ton Chain Pulley Is Welded On One Of The Transverse Pipe. The Wire Of Chain Pulley Reaches To A Rectangular Welded Pipe Of 410*2 Size Through Five Pulleys Of 4 Size. The Edge Of This Pipe Have Many Hooks To Attach A Strong Synthetic Cloth (56*53). This Cloth Has Five Holes To Accommodate The Limbs And Udder/Sheath Of The Animal. This Cloth Has Five Strips, Put Of Which To On Either Ends. These Strips Are Attached With Iron Rings At Their Respective Ends. Animals Legs Are Taken Out Of The Holes Of The Cloth And Cloths Rings Are Attached To The Rectangular Pipe Through Hooks. The Chain Pulley Is Used To Put Animal In Comfortable Position By Either Pulling Up Or Keeping Down. The Entire Device Is Portable And Can Easily Be Shifted Through Wheels. (As Per Enclosed Line Diagram) , Artificial Vagina With Metal Valve, 35 Cm. , Automatic Thawing Unit Electric 37° C , Automatic Vaccinatorbottle And Vial Attachment, Pressure Dose Adjustment From 0.5Ml To 5Ml, Luer Lock Needle Nozzle With Spare Service Kit. , Bacteriological Incubator Double Walled, Inside Chamber Made Of S.S. -304, Thermostatically Controlled, Temperature 37 Degree C+3 Degree C, Inner Glass Door,Built In L Shape Thermometer, 2 Pilot Lamps,On/Off Switch And Perforated Trays. 450Mm X450mm X450mm, Ce Certified , Bio Degradable Waste Bin Set Of 3 Having 20Ltr Capacity. Colour Red , Yellow And Blue With Trolley , Calf Pullerss 316/304. The Main Body Of The Device Should Be Attached To The Front End By A Hinge To Ensure Convenient Up And Down Movement With Operational Length 1200Mm Approx. Main Body Dimension 30X30mm, Front End Of Device U Shaped And Detachable From Body. Coparsises A Circular Tube With A Diameter Of 25Mm, Fexbility Provision Of The Device Should Be 275Mm To 400Mm Approx. The Device Should Have A Provision To Connect With An Obstetric Chain. Seperate Detachable Handle Of 200Mm With Twin Lock Mechanism.Ce Approved , California Mastitis Test Kitcomplete Kit Made Of Polypropylene With 4 Mixing Chambers And Full Grip Handle Including Reagent, Reagent Dispenser And Test Colour Standard Chart , Castrator (Emasculator), 19 Length Made Up Of Ss Non Magnetic Steel 304 Grade With Knee Support And Spanner For Tighting Of Bolts In Case Of Play , Cattle Crush Tubular, Made Of G.I. Pipe With Outside Diameter 60Mm, Height Of Front & Back Pillar 1980 Mm, Length & Breadth Of Cattle Crush Be 1830 X 877 Mm Respectively. All Four Pillars Should Be Provided Holes At 75Mm Distance From Bottom And Be Provided With Round Bars Of 12Mm Diameter & 300 Mm Long, Side Pillars Be Joined By 2 Tubular Beams Having 60 Mm Outside Diameter, The Insided Distance Between The Two Beams Being 477 Mm. The Two Sides Of Beams Should Be Supported By Two G.I. Pipers Of 48 Mm Diameter. Lower Side Beam At 1223 Mm Heightand Upper Side Beam At 1700 Mm Height. Circular 1 Inch Painted Marking On All Four Pillars At The Height Of 450Mm Frombelowto Indicate Ground Fill / Fixation. Cattle Crush Should Also Be Provided With An Adjustable Gate To Open Sides. Gate Should Consist One Sliding G.I. Pipe On Two Horizontal Pipe Of 60Mm Outer Diameter To Secure The Neck Of Animal. Two Extra G.I. Pipe 1.2 Mtr. Long Of 60Mm Outer Diameter Should Be Provided For The Backsides. Two Metalic Loops On Each Side Vertical Rear Pillar To Control Cattle From Backside Be Provided. All The G.I. Pipes Used Should Be Of Isi Mark A Class With Visible Isi Mark On Every Meter Of Pipe. All The Joints Should Be Electrically Welded. (Note-Weight Of The Cattle Crush Should Comply With The Norms Of The Isi Mark, A Class Gi Pipe Standard Of Specified Diameters With Variable Maximum/Minimum Permissible Limits). , Chuck With Key (Orthopaedic) S.S. -304, 20Cm , Clinical Centrifuge 8X15ml Swing Out Head, Rectangular Body, Fitted With Transparent Lid, Easy Locking System, Step Less Speed Regulator, 60 Minutes Timer And Speed Meter, Maximum Speed 5000 Rpm. , Clinical Thermameter Oc Isi Marked , Cryo Boxmadeup Of Autoclavable Holding 50 Vials (2.5 Ml) , Cryovials 2.5Ml Sterilized , Crystoscope (As Per Ivri Specification) , Dehorning Saw With Detachable Blades 45 Cm , Dipstick Fiber Sheet, 1 Mt. , Disposal A.I. Gloves, Made Of Ldpe Material, Length 34 Inch And Should Be Made Of Less Than 20 Micron Film. Lab Test Report Is Must For Film Used , Dog Muzzels -Standard , Dressing Forceps (S.S.-304) 15Cm , Dressing Forceps (S.S.-304) 25Cm , Easy Drencher Big Drencher Probe For Volume Drenching Of Mature Cattle, 2.5Ltr Capacity Wide Neck For Easy Filling Of Drenching Products 70Mm Diamater Good Hand Grip For Easy Handling In Drenching Big Drenchers Can Be Used For Calf With 300Mm Long Probe For Small Calf , Electric Dehorner 30 Cm Length , Elisa Plate 96Wells, Polysrerine , Enema Pump (Veterinary) Reedis Standard , Faecal Sample Collection Containers Individually Packed 70 Ml Capacity , Made Up Of Transparent / Clean Plasticwith Screw Capped Lid , Firing Iron Set (Conical,Line,Pin) , Forceps S.S. -304 15Cm , Forceps S.S. -304 17.5Cm , Forceps S.S. -304 20Cm , Formalin Chamber With 100 Formalin Tablets Non Corrosive,Standard, 20X 8X 8 , Full Rubber Apron, Standard , Gerlach/ Buhner Vulva Suture Instrument Ss -304,18 Cm , Goat A.I Kit A.I Sheath Individual Pack (Pkt Of- 50) A.I Sheath Container Plastic - 01 Small Vaginal Speculum - 01 Head Torch- 01 Straw Cutter- 01 Liquid Paraffin 500Ml- 01 Carbolic Soap 120 Gm- 04 Medicated Spirit 500Ml- 01 Absorbent Cotton 500Gm- 01 Cover Bag- 01 , Grays Mouth Gags For Dogs Ss-304, 11Cm , Grays Mouth Gags For Dogs Ss-304, 14Cm , Grays Mouth Gags For Dogs Ss-304, 16Cm , Hog Catcherstandard , Hoof Trimming Set (Consisting Of Hoof Cutter450-500Mm Length With Sharp Blade , Set Of 2 Hoof Knife With Wooden Handle And Ss Blade,Hoofrasp Made Up Of Mild Steel 20 Cm) , Instrument Tray S.S. -304With Lid 250Mmx300mm , Instrument Tray S.S. -304With Lid 350Mmx300mm , Insulated Sample Carrier Wide Mouth Vacuum Flask Made Of S.S. Inside And Out Side With Carrying Strap. Capacity 500Ml , Intra Medullary Bone Pins Assorted Size , Ln2 Pouring Spout, Fitted With Insulated Jet And Spl. Grade Rubber Stopper For Neck Locking , Long Forcep (Ss-304) 45 Cm , Metal Catheter For Bitch Standard , Mouth Gag Forcattle Standard , Non Electric Autoclave Vertical (Portable) (Ss-304) Size-450 Mm Height And 300 Mm Dia, Made Of Ss-304 Grade, Ss-304 Lid, Thick Bottom For With Standing Direct Flame Heat, Jointless Rubber Gasket. Should Be Fitted With Pressure Guage, Steam Release Cock, Safety Valve, Solid Iron Stand To Support Autoclave , Ointment Slab Porcelain 20 Cmx20 Cm , Operation Table For Small Animals-1- Operation Table For Small Animals Suitable For General Surgery Ss Hydraulic O.T. Table, Five Section Ss Top And Heavy Base And Column. All Sections Covered With Mattresses. Height Adjustable Range ( In Mm ): 75Mm To 1000Mm, Trendelenburg: 30 Degree, Max. Load 120 Kg , Table Lenght 1830Mm, Table Width 497Mm, Height Adjustable,Back Rest Up 80 Degree/Dowm 25 Degree, Lateral Tilt 20/20 Degree , Head Rest Up 20 Degree/Down 60 Degree, Trendelenburg Reverse 25 Degree , Orthopedic Saw, (Ss-304) 30 Cm With Adjustable Blades , Otoscope And Opthalmoscope Set Otoscope And Opthalmoscope Set Of Good Quality And For Veterinary Use.It Should Be Batteries Operated And Easy To Handle, Otoscope Head With 4X Magnification, 3 Specula Of Size 80Mmx6mm, 58Mmx5mm, 80Mmx4mm With One Spare Bulb, One Opthalmoscope Head. , Plaster Cutting Saw S.S. 4Cm Wide 20 Cm. , Plastic Box, Made Of Pp Material, Boilable150mmx135mmx130mm , Portable Electric Sterilizer(Ss 304), 30Cmx15cmx20cm-1500 Watt , Post Mortem Kit For Poultry-Scissors Mayos Ss, 20Cm-2, Scissors Mayos Ss, 15Cm-2, Long Forceps Ss 20Cm-2, Magnifying Glass, 6Cm Dia-2, Bone Cutter Ss, 20Cm-1, B.P. Handle Ss, No. 3 &4 Standard-2, B.P. Blade Ss Each-24. (Items Of Ss Should Of Be Ss-304 Material) , Postmortem Set : Comprising Postmortem Saw (All Metallic Saw 25Cm S.S.), Postmortem Knife 30Cm S.S., Set Of Hooks-23, Compass S.S.-25Cms, Chisel S.S. 15Cms-2, Hammer S.S.- 25Cms, Scalpel S.S.(05 Cms, 10Cms, 15Cms, 20Cms)-4, Scissors S.S. Straight 15Cms, 20Cms, Scissors S.S. Curved 15Cms, 20Cms, Thumb Forceps 15Cms, 20Cms, In A Canvas Bag.(Items Of Ss Should Of Be Ss-304 Material) , Postmortem Tray 18X10 Metalic , Ppe Kitdangri: 1 Disposable Free Size. Full Sleeves, Made Up Of Non Woven Fabric (Spun Bonded, Poly Propylene Material Not Less Then 90 Gsm) Cuff With Elastics Zipper Infront Hood Attached Covering Sides Of Face And Neck. Hand Gloves: One Pair Disposable, Isi Mark, Size 10 No. Shoe Cover :One Pair Disposable, Made Up Of Polyester Woven Fabric With Protective Rubber Coating Preferably Tetoron With Thick Padded Foot Base And Can Be Used Under Field Condition. Face Mask: 1 With Hepa Filter 3M-N95 Standard. Disposable 1 Protective Glasses : Disposable With Clear Glasses, Zero Power Eye Fitting And Elastic Band Holder. Note: Kit Must Be Disinfected By Gamma Irradiation And The Irradiation Certificate Required , Rubber Arm Sleeves With Latex Gloves No.8 , Rubber Arm Sleeves With Latex Gloves No.9 , Rubber Glovesfull Arm Sleeves , S.S. Tray 350X400mm(Ss-304) , S.S.-304 Jar With Lid 2 Kg. Capacity , Sample Container Plastic 100 Ml (Radiation Sterile) , Sheep Balling Gun Ss -304,31.5 Cm , Sheep Shearing Machine, Portable Sheep Shearing Machine With Drive And Hand Piece Rotary Speed 50 Hz, 220-240 V With Motor Power 280 W To 700 W And Rpm 2800 To 3500,Motor Weight 8 Kg To 12 Kg. - 1 No.Accessories For Sheep Shearing Machine :- (A) Combs (80 Mm To 90 Mm) - 20 Nos., (B) Cutters Four Teeth With Minimum Thickness Of 4 Mm - 20 Nos. , Grinder Unit For Sheep Shearing Machine;Portable Light Weight (20 - 25 Kg) Grinder With Motor Of 350 W Or Above And Speed 1200 To 2400 Rpm - 1 No. Accessories For Grinder Unit :-Emery Cloth/Paper Of 60 Grit - 20 Nos., Small Service Kit Of Hand Piece - 1 Set , Other Accessories For Sheep Shearing Machine : Small Service Kit Of Hand Piece - 1 Set , Other Accessories For Sheep Shearing Machine : Chicken Feet For Hand Piece - 1 Set , Other Accessories For Sheep Shearing Machine : Inner Gut Core Spring Of Flexible Drive - 1 No. , Single Pan Weighing Balance 100 Gm Cap. Electric Operated Calib. 0.0001Gm , Spatula Pvc 20 Cm , Sperm Processor/Sperm Warmer (Portable Frozen Semen Thawing Unit) Portable Frozen Semen Thawing Unit : Body Made Up Of Abs Plastic (Acrylonitrily Butadiene Styrene Plastic) Work On 230 V By Converting It To 12 V & Maintining The Temperature At 370 C + 0.20 Cwith Dual Temperature Display System (Set Temperature And Ongoing Temperature). Dry Both Having 6-7 Hours Battery Backup After Full Charging. Thawing Aluminium Alloy Block Must Hold Four Straws. Product Weight 500 Gm (0.5 Kg) Only. Instrument Provided With Solar Charging Pannel, Four Wheeler/Two Wheeler Charging Unit Also In The Same Port. Product Should Be Iso Nd Ce Accredited , Sprayer, Hand Operated Knapsack Sprayer Piston 08 Liters Capacity Tank. Pp Materia , Sprit Lamp With Tripod Stand S.S.(Ss-304) , Stomach Tube For Horseshape And Dimension Of Stomach Tube Should Be 16Mmx3400mm; Made Of Flexible Plastic; Optimum Rigidity And Good Reaction To Heat And Cold;A Round And Opened End With Lateral Eyes, Clear Tubes With A Funnel End; Shall Have Good Slide And Easy To Clean; Shall Be Covered By A Suitable Rust Proofing Material And Then Wrapped In Non-Absorbent Paper. , Straw Tweezer Made Of Special Grade Plastic Material To Avoid Heat Loss, For Handing Straws Of French Medium/Mini And German Pattern , Surgical Diathermy For Veterinary Suitable For Veterinary Diathermy. Output Frequency-Monopolar Generator 500+25Khz. Input Voltage 220-240 Volts Ac 50Hz , Surgical Table, Surgical Table Made Up Of Stainless Steel Size 6Ft X 3Ft Having Provision Of Drainage And Washing System Of Table After The Operations.Having Provision Of Iv Stand On All Side Of Table With One Iv Stand That Can Be Used In All Side And Having Storage Drawer On The Back Of Top Of Table That Can Used Wisely 18X30 Drawer Size With Handle On Both Side And Tying O Ring For Tying Belt In Length Side 2 Dia , Suture Needles Traumatic/ Atraumatic/ Curved/Straight , Swab Holder S.S. -304 , Tail Docking Machine 55 Cm , Taylor Percussion Hammer 18Cm Ss -304,With Hard Plastic Head , Tooth Cutter For Large Animals Ss-304 , Tooth Rasp Standard , Trocar And Canula For Large Animal- Trocar 10X150mm With Wooden Handle Along With Canula , Trocar Canula For Sheep 15 Cm , Urinary Catheters Nielsen Urinary Catheter For Cow- Length-44 Cm, Dia-5Mm-Ss-304 , Vaginal Dilator For Bitch -Standard , Wash Basin With Tank Ss-304 On Stand 90Cm Height& 5 Liter Tank Capacity , Water Bath Circulator , Acrylic Body, Digital Display 390X120x160mm , Weingart Rumenotomy Set .Weingart Frame-1, Vulsellum Forceps-2, Weingart Tenaculum-6 , Wire Saw With Handles
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 18
Uttar Pradesh View Result →
42.
Agriculture #9489718 Technical Bid
Supply Of Spares For Air Conpressor And Service , Spares For Ingersollrand Make Air Compressor Model 8 X 5 Esv-1 Lub , Valve Discharge Complete , Channel & Spring Set Discharge , Channel & Spring Set Suction , Cap Screw , Lock Washer , Valve Inlet Complete , Plunger Unloader , ‘O’Ring , Springplunger , Piston Ringset (C.I.) , Cap Screw Gauge Hex Head , Gasket Set Complete , Seal For Oil Pump (Lub.) , Oil Lubricator Complete , Auxillary Valve , Stop Plate Discharge , Stop Plate Suction , Ht Bolt D-7,D-8,D-9,D-10,D-14, D-11, D-13 , Flat ‘O’ Ring U/L , Glass Lubricator , Flat ‘H’ Screw , Cylinder Block 8 , Oil Seal Crank Shaft , O Ring For Oil Chamber , Valve Seat Plate (Discharge) , Air Scraper Ring , Oil Scraper Ring , Star Washer Piston Ring , Air Filter Element , Oil Pressure Gauge 63 Mm , Plunger Cover U/L , Oil Pump Housing , Oil Stainer , Rubber Star Coupling For Lubricator , Crank Shaft Bearing Right Side , Crank Shaft Bearing Left Side , Crank Shaft Centre Bush , Crank Shaft Oil Seal , Guide Holder , Air Pressure Ring , Oil Pressure Ring , Wheel Mounting Sleeve , U/L Repair Kit , Discharge Valve Mounting Bolt With Washer , Suction Valve Mounting Bolt With Washer , Wheel Mounting Sleeve , U/L Repair Kit , Discharge Valve Mounting Bolt With Washer , Suction Valve Mounting Bolt With Washer , Oil Filter , Port Plate Up Site , Port Plate Down Side , Hex Bolt Port Plate , Fau Kit , Oil Scrapper , Packing Ring , Oil Seal , Complete Assembly Valve (Suction) , Complete Assembly Valve (Discharge) , Brass Connector With Nit , Spares For Ingersollrand Make Air Compressor Model 9.5 X 7 Esv-1 Lubricated , Channel & Spring Setdischarge , Channel & Spring Set Suction , Discharge Valve Complete , Unloader Fre Air Complete , Cap Screw , Lock Washer , Plunger , Spring , ‘O’ Ring , Plate Seat , Platestop , Air Filter , Dowel Pin , Machine Screw , Gasket Set , Oil Filter , Ht Bolt D-7,D-8,D-9,D-10,D-14 , Lubricator , Oil Scrapper Set , Auxilarry Valve , Piston Ring C.I. , Suction Valve , Rubber Star Coupling , Valve Seat Plate Discharge , Valve Seat Plate Suction , Star Washer , Air Scraper Ring , Valve Plate Screw , Oil Stainer , Oil Pump Housing , Plunger U/L Complete With Cover , Unload Flat O Ring , Crank Shaft Oil Seal , Air Pressure Ring , Oil Pressure Ring , Guide Holder (D) , Guide Holder (S) , U/L Rubber O Ring , U/L Teflon O Ring , Valve Seat Plate (Suction) , Air Filter , Oil Filter , Pump Shaft Oil Seal , Oil Pressure Gauge (6 Kg/Cm) , Lubricator Coupling , Gasket Set , U/L Repair Kit , Bottom Colling Rubber O Ring , Suction Valve Cover , Guide Holder Diaphragm , Packing Ring , Complete Assembly (Suction) , Complete Assembly (Discharge) , Valve Assembly Hex Bolt Port Plate , Valve Assembly Hex Bolt (Short & Long) , Valve Chamber Plate Hex Bolt , Brass Connector With Nit , Spares For Ingersoll Rand Make Air Compressor Model11 X 7 Esv-1 Lubricated , Discharge Valve Complete , Seat Valve , Plate Seat , Guide , Dowel , Plate Stop , Channel & Spring Set(Discharge) , Machine Screw , Machine Screw , Lock Washer , Inlet Valve Complete , Seat Valve , Plate Seat , Guide , Dowel , Channel & Spring Set (Suction) , Machine Screw , Plunger , Spring , Plunger U/L , Screw For Suction Valve , Spring Lift , Pistion Ring Set , Screw F.H.D. Cvr , Screw F.H.D , Lock Washer , Screwx12a , Reducer , Wing Nut , Aux. Valve Complete , Washer Star Head , Discharge Valve Carb.. , Plate Stop , Air Filter , Guide Holder (Discharge) , Gasket Set , Screw Guide Holder , Ring Piston Set , S.S.Screw For Discharge Valve , Screw For Suction Valve , Valve Seat Plate (Discharge) , Air Scraper Ring , Oil Scraper Ring , Chamber Filter , Cover Gasket O Ring , Suction Valve Cover Rod , Piston Ring , Guide Holder , Screw For Valve Plate , Screw For Cover , Valve O Ring , Valve Copper Gaskit O Ring , Valve Cover Copper Gaskit O Ring , Guide Holder (Suction) , Valve Seat Plate (Suction) , Gasket Set Metallic , Valve Seat Plate (Suction) , Packing Ring , U/L Repairing Kit , Hex Bolt Valve Cover , Spares For Ingersollrand Make Air Compressor Model 7 X 5 `V-1 Lubricated , Inlet Valve Complete , Channel & Spring Set (Discharge) , Cap Screw Hex-Hd , Spring , ‘O’ Ring , Discharge Valve Complete , Plate Stop (Discharge) , Guide Valve , Dowel , Lock Washer , Lock Washer Star , Nut X Headjam , Plate Seat (Discharge) , Guide Holder (Discharge) , Gasket Set , Flat ‘O’ Ring U/L , Rubber ‘O’ Ring U/L , Oil Ring Scrapper , Coupling (Set Of 2 Nos) , Lubricator , Air Scraper Ring , U/L Valve (7 Kg/Cm² Pressure) , Head H.T.Bolt End , Head H.T.Bolt Outer , H.T. Bolt D-11, D-13 , Piston Ring (C.I.) , Auxillary Valve , Pump Oil Seal , Air Pressure Ring , U/L Spring , Channel & Spring Set (Suction) , Plate Stop (Suction) , Guide Holder (Suction) , Plate Seat , Gland Copper Gaskit , U/L Teflon O Ring , Main Bearing , Cr Bearing , U/L Repair Kit , Oil Seal For Crank Shaft , Air Filter Complete , Fau Kit , Packing Ring , Oil Filter , Star Coupling , Oil Seal , Brass Connector With Nit , Head Bolt , Spares For Ingersollrand Make Air Compressor Model 8 X 7 Esv-1Non-Lubricated , Channel & Spring Set Inlet , Channel & Spring Set Disch.. , Ring & Spring Packing Set , Ring Oil Scrapper Set , Ring Oil Scrapper Set , Ring Piston Set , Gasket Set Complete , Cap Screw Cage Pau , Cap Screw Plate Seat , Cap Screw Seat Valve , Cap Screw- Stp-Val Dis.. , Cap Screw-Stp-Plt In Vlv.. , Lock Washer Star , Oil Filter , Valve Discharge Complete , Valve Inlet Comlete , Unloader Fre Air Complete , Cage Unloader , Plunger Unloader , Spring Unloader , ‘O’ Ring , Ring Piston , Cap Screw Valve Seat , Teflon Guide , Guide Holder Teflon , Wear Ring , Piston Ring , Ring And Spring Set , High Tension Bolt D-7 , Do But D-7 , High Tension Bolt D-9 , Top Cover Bolt , Wear Ring , Rubber ‘O’ Ring U/L , Flat ‘O’ Ring U/L , Flat ‘H’ Screw , Bottom ‘H’ Screw , Oil Scrapper Set , Auxillary Valve , Gasket Set , Piston Ringteflon , Wear Ring Teflon , Valve Discharge , Valve Seat Plate , Valve Stop Plate Suction , Air Scraper Ring , Oil Scraper Ring , Oil Seal For Crank Shaft , Housing Rubber , Channel Strip Teflon , Air Pressure Teflon Ring (Discharge/Suction) , Lubricator Oil Pump , U/L Repair Kit , Air Filter , Spares For Model 244 Ingersoll Rand Make , Connecting Rod Lp & Hp , Gasket Set , Piston Lp & Hp , Crank Pin Bush , Valve Plate Lp & Hp , Finger Strip Lp & Hp , Piston Ring L.P./H.P. , Valve Pattin L.P./H.P. , Valve Plate L.P./H.P. , Air Filter Complete , Safty Valve Size 1/2 , Non Return Valve Size 1 , Pressure Switch , Model Kirloskar Eh 100 , Discharge Valve Complete , Suction Valve Complete , Gasket Set , Piston Ring Set , Auxilary Valve , Lock For(Suction) Fork , Main Bearing Set , C.R. Bearing Set , Rubber ‘O’ Ring U/L , Tie Bolt Complete With Washer Nut And Socket , Lanten , Valve U/L Plunger , Valve O Ring , Oil Pressure Guage 2 Dial , Valve Unloader , Lock Pin For Connecting Rod , Oil Pressure Limit Switch , Gaskit For Cylinder , Gaskit For Head , Suction Filter , Lock For Suction Valve , Copper Ring For Valve (L.P.) , Copper Ring For Valve (H.P.) , Rubber Ring (L.P.) , Gaskit For Valve (H.P.) , Piston Ring C.I. (Pressure Ring) , Nrv Valve With Body , Cylinder Standard , Pressure Regulator 7 Kg , Oil Filter , Valve Repairing Kit (Suction) , Valve Repairing Kit (Discharge) , Diaphragm Unloader Assembly , Spares For Air Compressor Model Ir 4X4X2¾ , Piston Ring Set , Gaskit Set Complete , Oil Seal , Air Filter , Servicing Charges Of Above Air Compressors
Contract Date: Ref. Documents Contract Value : Ref. Document
Cooperative No of Bidders 1
Uttar Pradesh View Result →
44.
Agriculture #9483520 Technical Bid
Compititive Ebidding For Supply Of Hardware Items For Season 2025-26 , Hardware Items , Rubber Oil Seal Metallic & Non Metallic Mykoda/Oskomake , All Type Of Gun Metal Valves Serewed & Flanged From 3/8” To 2” Make Zoloto/Leader , Ss Ball Valvesscrew End Isi Mark , Size- 3/8” , Size- ½” , Size- ¾” , Size- 1” , Seamless Pipe Size ½” To 10” With Ibr Test Certificate Msl Make , Teflonrod ( White) , 1” X 12” , 1 ½X 12” , 2” X 12” , Metalon Sheet 1Mtr X 1 Mtr X 1 ½” Thik. , Nylon Wire Brush 20Mm , Metlenrod , 65Mm X 300Mm (Solid) , 75Mm X 300Mm (Solid) , 90Mm X 300Mm (Solid) , 100Mm Od X 70Mm Id X 300Mm Length (Hollow) , 110Mm Od X 80Mm Id X 300Mm Length (Hollow) , 120Mm Od X 70Mm Id X 340Mm Length (Hollow) , Flat Belt Dunlop / Goodyear Make , 2” X 4 Ply , 4” X 4 Ply , 5” X 8 Ply , 6” X 8 Ply , Rubber House Pipe Double Ply , Size ½” , Size ¾” , Size 1” , Wire Braded Flexible Pipe With Both End Connectors , Size ¼” X ¼ Mtr , Size ¼” X ½ Mtr , Size ¼” X 1Mtr , Size ¼” X 1 ½ Mtr , Size ¼” X 1 ½ Feet , Size 3/8” X ¼Mtr , Size 3/8” X ½ Mtr , Size 3/8” X 1 Mtr , Size 3/8” X1½ Mtr , Size 3/8” X 1 ½ Feet , Size ½” X ½ Mtr , Size ½” X 1 Mtr , Size ½” X1½ Feet , Hydraulic Rubber Hose Pipe With Both End Connectors , Size¼” X 2 Feet , Size3/8” X ½ Mtr , Size3/8” X 1Mtr , Size 3/8” X 1 ½ Feet , Size 3/8” X 4 Feet , Size½” X 2 Feet , Size ½” X 2 ½ Feet , Size ¾” X 3 ½ Feet , Oil Fiter Hydroline Make , Size Sc-050 , Size Sc3 -015 , Size Sc3- 010 , Steel Wire Hand Brush 6” X 2” , Brake Liner 6” Wide X 10Mm Thick , Thermometer 0-110°C , Painting Brush , Size 2” , Size 3” , Size 4” , Size 5” , Size 6” , Redoxide Primer British Paint/Asian Make ( 20 Litr Drum) , G.P Thiner 20 Litr Drum , Brass Strip 25Mm X 25Mm X 1.5 Mtr Long , Brass Rod ½” To 2” , Dunlop Make Rubber Adhesive 786 1 Kg Packing , Araldite Ciba-Giegy Make , 36Gm Set , 72Gm Set , 180 Gm Set , 100 Gm Set , Dendrite Tube 25Ml , M-Seal Mahindra / Pidlite/Astral , M-Seal Phataphat 30Gm Set , Boiler Gauge Glass Bishop Make , Size ¾” X 16” ½” , Size ¾” X 22 ½”Boiler Gauge B-9Glass , Klinger Make Gasket For B9 Glass , Rubber Cone ¾” For Gauge Glass National/Leades Make , Sleeve 3/4” For Gauge Glass Leader Make , Mica Sheet For B- Gauge Glass , Manila Rope ¾” & 1” , Pvc Rope ¾” & 1” Garware Make /Trishul Make , White Asbestos Rope1/8 , White Asbestos Rope3/8 , White Asbestos Rope1/2 , White Asbestos Rope3/4 , Solenoid Valve With Coil Rotex Make , Model No – 3012 Two Way , Model No- 3013 One Way , General Items , Aluminum Rivet ¼” X 2” /1/4” X 2 ½ , Hydex Ci Coupling M-48 Complete Set Dyna Make , Teflon Tap ¾” X 10 Mtr , Holdtite Compound 500 Ml Pidlite Make , Restolene Pidlite Make 50Ml , Gasket Shellac Compound 25Ml , Blue Tube 25Ml Atlas Make /Camel Make , Piano Wire 250 Gm Roll , Brasso 100 Ml , Graphite Powder , Stag Jointing Paste, Type B-Red, 500Gram , Emery Tape(Rough 2) , Emery Tape(Fine 2) , Emery Cloth(Rough) , Emery Cloth(Fine) , Hexsaw Blade 1/2 X12 Miranda Make , Shellac Compound(250/25Gm) , Thread Locker/Loctite (No. 112) 250Ml Anabond Make , Grinding Wheels Ag4 Dewalt/Bosch Make , Grinding Wheelsag7 Dewalt/Bosch Make , Buffing Wheels4 Dewalt/Bosch Make , Buffing Wheels7 Dewalt/Bosch Make , Ci Pulley Wk 1500M/C Od-310Mm, Bore-97Mm, Spc/C Groove-05 Grooves On Conversion , Ci Flange Coupling 8 With Bush Complete Set , Copper Pipe Od-6Mm , Needle Valve 1/2 , Brass Ferulls Id-6Mm , Oil Packet Ss 12 , Cotton Waste , Markeen Cloth , Angle Grinder 4 , Angle Grinder 7 , Cast Steel Gear Couplings , Gc-102 , Gc-103 , Gc-104 , Gc-105 , Gc-106 , Gc-107 , Gc-108 , Gc-109 , Gc-110 , Bearing Sleeves Of All Sizes Jmc Make , Copper Flatsheet , Graphite Crucible Double Kabootar Make , 80No , 100 No , Wire Braded Rubber Hose Pipe ¾” For Steam , Diamond Make Simplex Chain 2 ½ Pitch , 1”Pitch , 2” Pitch , 2 ½” Pitch , 3” Pitch , Full Link Coupler 2 ½” Pitch , Half Link Coupler 2 ½” Pitch , Love Joy Ci Coupling Set , L-70 , L-75 , L-90 , L-100 , L-110 , C.I Tyre Coupling Set Complete , Px-50 , Px-60 , Px-70 , Px-80 , Px-90 , Px-100 , Px-110 , Px-120 , Px-140 , Ph-140 , Ph-176 , Ph-190 , Ph-218 , Spare Coupling Tyres , Px-50 , Px-60 , Px-70 , Px-80 , Px-90 , Px-100 , Px-110 , Px-120 , Px-140 , Ph-140 , Ph-176 , Ph-190 , Ph-218 , “Usha” Martin Make Steel Wire Rope ¾”/6/36” Hemp Core With Test Certificate (305Mtr) , High Tensile Bolt/Nut “Unbrako”Make , “Indef” Make Chain Blocks With Test Certificate With10 Mtr Lift , Capacity 1 Ton , Capacity 2 Ton , Capacity 3 Ton , Capacity 5 Ton , Capacity 10 Ton , Wire Braded Rubber Hose Pipe ¾” For Steam , Spares For Sugar Weighing & Bagging Machine , Janatics Make Solenoid Valve With Coil 3/2 Way , Load Cell, Capacity 110Kg, , Pu Tube Size Id-6Mm, Od-8Mm , Pu Tube Sizeid-8Mm, Od-10Mm , Air Filter Regulator Size 1/4 Bsf , Straight Connector 1/4 , Tee Connector- Push Type 1/4 X 8Mm , Temp., Pressure, Vaccum Guages , Temp Gauge Range 0-150 Degree C Dial Size 6”. Stem Dia-8 Mm (Probe Type) Connection -1/2” Bsp (M) Make- Hguru/ Bomber Mounting –Direct Bottom , Temp Gauge Range 0-100 Degree C Dial Size 6”. Wired Type- 8Mtr Connection -1/2” Bsp (M) Make- Hguru/ Bomber Mounting –Direct Bottom , Temp Gauge Range 0-200 Degree C Dial Size 6”. Wired Type- 8Mtr Connection -1/2” Bsp (M) Make- Hguru/ Bomber Mounting –Direct Bottom , Vacuum Gauge Range 0- 760 Mmhg Dial Size 6”. Connection: ½” Bsp (M). Make- Hguru/ Bomber Mounting –Direct Bottom , Temp Gauge Range 0-600 Degree C Dial Size 6”. Wired Type- 8Mtr Connection -1/2” Bsp (M) Make- Hguru/ Bomber Mounting –Direct Bottom , Temp Gauge Range 0-200 Degree C Dial Size 6”. Stem Dia-8 Mm (Probe Type) Connection -1/2” Bsp (M) Make- Hguru/ Bomber Mounting –Direct Bottom , Temp Gauge Range 0-600 Degree C Dial Size 6”. Stem Dia-8 Mm (Probe Type) Connection -1/2” Bsp (M) Make- Hguru Mounting –Direct Bottom , Pressure Gauge Range 0-4Kg/Cm2 Dial Size 6”. Connection -1/2” Bsp (M) Make- Hguru/ Bomber Mounting –Back Nut , Pressure Gauge Range 0-60Kg/Cm2 Dial Size 6”. Connection -1/2” Bsp (M) Make- Hguru/ Bomber Mounting –Back Nut , Circular Exhaust/Steam Pressure Graph Paper , Lock For Bearing Sleeve H309 , Lock For Bearing Sleeve H307 , Inner Circlip Lock 9 , Inner Circlip Lock 7 , Plumber Block Sn513 Heavy Duty , Plumber Block Sn518 Heavy Duty , Plumber Block Sn515 Heavy Duty , Plumber Block Sn522 Heavy Duty , Plumber Block Sn613 Heavy Duty , Plumber Block Sn615 Heavy Duty , Plumber Block Sn622 Heavy Duty , Plumber Block Sn526 Heavy Duty , Grub Allen Key Bolt 10 X 50Mm , T.S. Drill 15/16” , T.S. Drill 7/16” , Measuring Compass Combination Of Inside & Outside Size 8”(200Mm) , Vernier Caliper 300Mm(Mitsubishi) , Electric Impact Wrinch,750 Watt, 230V, 50Hz Make-Dewalt Model Dw-292 , Circlip 19Mm Internal , Circlip 21Mm App. External , Circlip 60Mm App. Internal , Bearingba 1816 , Bearing Axk 7095 , Bearing Axk 5070 , Bearing Axk 81114 , Flexible Hand Grinder For 2” Wheel Sf-2 Model Along With Shaft Rally Wolf Make 10 Fd Accessories , Dendrite Tube 20 Ml , Trippler Hydraulic Hose Pipe Sae 100R At, 5/8” With Capacity Of 250Bar ,Length 32” , Teflon Rod 20Mm Dia X 300Mm Length , Teflon Rod 35Mm Dia X 300Mm Length , Ferrule 6Mm(Brass) , Spring Washer Bbbb Make Good Quality , Size 18Mm , Size 3/8”(100 Piece Pack) , Size ¼”(100 Piece Pack) , Size 5/8” (100 Piece Pack) , Wooden Hand Wire Brush 3” X 6” Good Quality , Gm Globe Valve Screw End Tested At 500Lbs Per Square Inch Pressure In Following Size Sant Make , Size ½” , Size 3/4” , Size 1” , Size 3/8” , Gm Globe Valve Flange Type Sant Make , Size ½” , Size 1” , Hose Pipe Clamp 1” , Loctite 609 50Ml , Loctite 641 50Ml , Tap Set 16Mm Itt Make , Tap Set 14Mm Itt Make , Emery Paste Rough 500Gm , Emery Paste Fine 500Gm , Anabond 666 250Ml , Hand Drill Machine (Pistal Drill M/S) , Lock-Plier For Circlip Taparia Make , Flexible Pipe Size ½” X 1.5 Mtr , Gun Metal Strip For Plough Key Size 16Mm X 25Mm X 1.5Mtr , Grinding Wheel For Flexible Hand Grinder Size 2” , Thread Locker 641 250Ml , Split Pin Champion Make , Size ¼” X 2” (100 Piece Pack) , Size ¼” X 2 ½” (100 Piece Pack) , Size ¼” X 3” (100 Piece Pack) , Circlip Having Bore/Id -19Mm , Circlip Having Od -60Mm , Bearing Ucp208 , Cutting Wheelbosch Make Ag-4 , Cutting Wheelbosch Make Ag-7 , Siliconbrazing Rod Size 3Mm , Buffing Wheel Ag-4 , Stainless Steel Plate ,Grade 304 Plain Sheet Size- 4Feet X 8Feet X 3Mm Thickness , Klinger Makeb-9 Borosilicate Gauge Glass Imoported
Contract Date: Ref. Documents Contract Value : Ref. Document
Cooperative No of Bidders 3
Uttar Pradesh View Result →
45.
Heavy Industries and Public Enterprises #9468585 Technical Bid
Tender For Construction Of Entrance Gate Security Hut, Including Beautification 2 N, Bus Shelter-1 N, Upgradation Of Cfc Building 1 N, Ev Charging/Smart Vehicle Parking Civil Works 1 N, Integrated Command, Control N. Center 1 In Upsida Ia Pratapur, Udyogpuram. - Construction of Entrance Gate Security Hut, Including Beautification 2 N, Bus Shelter-1 N, Upgradation of CFC Building 1 N, EV Charging / Smart Vehicle Parking (Civil Works) 1 N, Integrated Command, Control N. Center – 1 In Upsida I.A. Pratapur, Udyogpuram In Meerut (U.P.). Sl. No. Item Description 1 CARRIAGE OF MATERIALS By Mechanical Transport including loading, unloading and stacking of Earth up to 1 km 2 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.All kinds of soil 3 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 4 Supplying chemical emulsion in sealed containers including delivery as specified. 5 Chlorpyriphos emulsifiable concentrate of 20% 6 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: 7 With Chlorpyriphos E.C. 20% with 1% concentration 8 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 9 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 10 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 11 Providing and laying Cement concrete 1:4:8 (1 cement : 4coarse sand : 8 graded stone ballast 40 mm nominal size) including supply of all materials.labour and T&P etc. required for proper completion of the work and curing complete. also including cost of formwork in foundation 12 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth 13 T.M.T.-FE-500 steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and wastage & over lapping & hooks. 14 Up to Plinth Lvl- 15 Above Plinth Lvl- 16 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately). 17 All works upto plinth level 18 All works above plinth level upto floor V level 19 Add for using extra cement in the items of design mix over and above the specified cement content therein. 20 Centering and shuttering including strutting, propping etc. and removal of form for 21 Foundations, footings, bases of columns, etc. for mass concrete 22 Suspended floors, roofs, landings, balconies and access platform 23 Shelves (Cast in situ) 24 Lintels, beams, plinth beams, girders, bressumers and cantilevers 25 Columns, Pillars, Piers, Abutments, Posts and Struts 26 Stairs, (excluding landings) except spiral-staircases. 27 Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 28 Edges of slabs and breaks in floors and walls 29 Under 20 cm wide 30 Weather shade, Chajjas, corbels etc., including edges 31 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at alllevels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan areato be measured). 32 Suspended floors, roofs, landings, beams and balconies (Plan area to be measured) 33 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 34 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 35 Cement mortar 1:4 (1 cement : 4 coarse sand) 36 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in : Cement mortar 1:6 (1 cement :6 coarse sand) 37 Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry 100 mm/ 125/150 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. 38 Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry with 150mm/200mm/230mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 39 Providing and fixing 18mm thick gang saw cut (premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels. 40 Granite of any colour and shade 41 Area of slab upto 0.50 sqm 42 Area of slab over 0.50 Sqm.( For Counter) 43 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-inCharge. 44 Granite work 45 Extra for fixing marble / granite stone over and above corresponding basic item, in facia and drops of width upto 150mm with epoxy resin baesd adhesive including cleaning etc. complete. 46 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/Stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edge etc. complete. 47 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : 48 Float glass panes 49 4 mm thick glass pane (weight not less than10kg/sqm). 50 Providing and fixing of Flush doors commercial quality conforming to I.S. 2202 part-I (1983) including fixing of wooden cleats and stoppers and including fixing and adjustment of hinges, bolts locks, handles spring fitting with necessary screws to be supplied departmentally. 35 mm thick 51 (a) Single leaf 52 Providing and fixing of flush door shutters commercial quality conforming to IS : 2202 Part I (1983) including fixing fixing of wooden cleats & stoppers and including fixing and adjustment of hinges, bolts locks, handles, springs and other fittings but excluding their supply and including painting with two coats of black Japan paint on all iron fitting if necessary. Fitting with necessary screws to be supplied departmentally. 53 35 mm thick 54 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 55 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured):(Rectangular or Squre) 56 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). 57 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 58 2nd class teak wood 59 50x12 mm 60 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding 61 Providing and Fixing door frame fabricated from sections roll formed out of 1.2mm thick galvanized steel (Base steel as per IS 513) with zinc of 120 gms/sq.mtr. The overall size of the section should be 105x60mm with rebate of 37mm for shutter. The frame section should be cut to length and metre joined with corner brackets made of CRCA electroplated.The frame should be provided with (a) 3 Nos. of M.S. powder coated 4” Butt hinges of 2mm thickness welded to the frame. (b) 6 Nos. of 1.2mm thick CRCA electroplated stiffeners should be welded to frame.(c) 6 Nos. of 8” M.S. hold fasts with split end tail welded to stiffener plates.(d) One no. aldrop receiver.(e) Each frame should be provided with 25x50mm tie rod at bottom. All welded places should be treated with protective coat of zinc rich primer.The entire frame should be provided with a coat of etched primer. 62 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 63 Providing and fixing aluminium Sliding Door Bolts ISI marked anodised transparent or dyed to required colour or shade with necessary screws etc. complete300x16mm 64 250x16 mm 65 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 66 (a) 250 mm x 10mm 67 (b)150x10 mm 68 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm 69 100 MM 70 Providing and fixing aluminium hanging floor door stopper, ISI marked , anodised transparent or dyed to required colour and shade with necessary screws etc. complete. Single rubber stopper 71 Twin rubber stopper 72 Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete. 73 Providing and fixing aluminium casement stays, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 74 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 75 1. mm thick 76 Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and lnline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all comers, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing confonning to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.Wire mesh I Glazing of plain/ toughened/ laminated/ double glass unit with I without high perfonnance coatings as per design requirements and confonning to IS: 3548 & IS: 16231 shall be paid separately.Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for :(i)Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3(ii)Sites with structure height more than 20m for all wind speeds 77 Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.Using R2 series with frame (40 mm & above) x (40 mm & above) & sash (25 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook (Height upto 1.2 metre). 78 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 79 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) 80 Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 81 10 x 140 mm 82 Providing & fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing & making curvature (wherever required) & fitting the same with necessary stainless steel nuts & bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Eng-in-charge. (weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 83 Providing & Fixing of window made of pre painted steel ( base Steel as per IS -513of 0.58 mm thick D quality galvanizedas per IS 277 with Zink of 120 GSM ) primer coated with epoxy primer of 5-7 microns thick , finish painted with a polyester paint of 12 -16 microns thick and back coatedwith 5-7 microns thick alkyd backer .section of outerframe should be of72 x 55 mm , centre mullion should be of72 x 50 mm , section for fixed glass beadingshould be of12 x 12 mm and sectionfor shutter should be of47 x 20 mm , outer frame and mullion section to have rebate forglazed shutters , flymesh shutters and 20 mm provision for gaurd bars / grill fly mesh shutters section should be of 20 x 40 mm. The section are to be cut to length mitre jointed with corner bracket , centre mullion to be fixed with mullion cap .Elixir or equivalent stay, handles 2nos of heavy dutystain less steel pivot hinges shall be provided per shutter. The windows should be paneled with 4 mm thick plain float glass and S.S. Mesh for fly mesh shutter (304 grade). Rubber Gaskets are provided all around the glass. The above frames should be fixed to the concrete/masonry wall by means of self expanding screws. Including 10mm squareguard bars with 6” (152.4mm) pitch, complete for finish item of work 84 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 85 40 mm thick with 20 mm nominal size stone aggregate 86 25mm Thick Kota Stone Slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mix with pigment to match the shade of slab includig rubbing and polishing complete with base of cement morter. 87 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete 88 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. 89 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 90 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 91 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),ointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. (Size of tiles 600x600mm) [Flooring] 92 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 93 Double charge vitrified tile polished finish of size 94 Size of Tile 600 x 600 mm 95 Glazed Vitrified tiles Matt/Antiskid finish of size 96 size Size of Tile 600x600 mm 97 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. (Size of tiles 600x600mm) 98 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm 99 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge 100 Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 101 Painting top of roofs with bitumen of approved quality@ 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : 102 With residual type petroleum bitumen of grade VG -10 103 10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: 104 With common burnt clay F.P.S.(non modular) brick tile of class designation 1O 105 Providing and laying gola 75x75mm in cement concrete M15 grade including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design in 75x75 mm deep chase. 106 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 107 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 108 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) 109 15 mm thick plinth plaster [1 cement : 4 coarse sand] 110 6 mm thick plinth plaster [1 cement : 3 FINE sand] 111 Extra for plastering done on moulding, cornices or architraves including neat finish to line and level: 112 In two coats 113 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. 114 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 115 French spirit polishing :Two or more coats on new works including a coat of wood filler 116 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer 117 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 118 Finishing walls with Acrylic smooth exterior paint of required shade: - New work (Two or more coats applied @ 1.43 Itr/10 sqm overand including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 119 Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work 120 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead 121 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 400 mm dia piles 122 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. 123 Note: 1. Initial and Routine Load Test shall not be carried out byDynamic method of testing. 124 Note: 2. Testing agency shall submit the design of loading platformfor the approval of Engineer-in-charge 125 Single pile upto 50 tonne Safe capacity 126 Initial test (Test Load 2.5 times the Safecapacity) 127 Routine test (Test Load 1.5 times the Safecapacity 128 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 129 For fixed portion 130 Powder coated aluminium (minimum thickness of powder coating 50 micron) 131 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 132 With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) 133 Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/ structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600 134 Upto 5mm depth and 5 mm width 135 Providing and laying water proofing treatment in sunken portion of WCs,bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry 136 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. 137 (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth ofapproved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 138 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 139 Providing and fixing EV CHARGING as per attached quotation 140 Supply and installation of TRICOLOR FLYING HIGH MAST POLE SIZE 30M. 141 PART B(PLUMBING WORKS ) 142 Sanitary Fixtures & CP Brass Fittings 143 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting,of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres),including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. 144 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), havingwater inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. 145 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 146 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 147 White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap 148 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : 149 Kitchen sink with drain board 510x1040 mm, bowl depth 200mm. 150 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 151 Providing and fixing P.V.C. Waste pipe for sink or wash basin including P.V.C. waste fittings complete. 152 Semi rigid pipe 153 40 mm dia. 154 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 155 Providing and fixing toilet paper holder : 156 C.P. brass 157 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 158 15 mm nominal bore 159 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 160 15 mm nominal bore 161 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 162 Providing and fixing uplasticised PVC connection pipe with brass unions : 163 45 cm length 164 15 mm nominal bore 165 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 166 Providing and fixing C.P. cast brass twin coat hooks fixed to PVC rawl plug with SS screws Jaquar model. No. AKP-35761P or approved equivalent. 167 Providing and fixing health faucet with 1 m long flexible tube and wall hook including all fittings Jaquar model No.ALD-CHR-593N or approved equivalent. 168 Providing and fixing 15mm C.P brass Sink Mixer Jaquar Model. No. CON-309KN or approved equivalent.) for kitchen sink with swinging spout complete. Including cutting and making good the walls wherever required . 169 Providing and fixing Grab Bar Jaquar Model No. AKP-35701P or approved equivalent,Including cutting and making good the walls wherever required 170 Providing and fixing 150 litre/ hr. cooling and storage capacity,fully stainless steel electric storage type water cooler ( Blue Star model No. SDLX 15150 or equvalant) with inlet hose connection inbuilt float valve. 2 Nos. outlet foucet, drain tray with waste and pipe up to fllor trap heavy compressor and wire up to socket, 3 pin plug etc complete in all respect. 171 Supplying, installation, testing and commissioning of skid mounted fully automatic Reverse Osmosis System of output capacity 50 litres / hour designed at a minimum Flux at inlet complete as required. 172 Providing and fixing vertical storage type hot water heater fixed to wall with anchor bolts & nuts, 15mm CP brass angle stop cock and 15mm CP brass non-return valve complete including making connections with 15mm dia CP connecting pipes on inlet and outlet, suitable length of power cable and 15 amps plug (Venus or approved equivalent). 173 Capacity 25 Litres Model 25 GV 174 Providing and fixing fully automatic Hand dryer Euronics Model-EH 26 NW or equvalant ,including all fittings complete in all respect. 175 Providing and fixing Air Purifier Euronics Model-EA 24 or equvalant ,including all fittings complete in all respect. 176 Soil, Waste, Vent & Rain Water Pipes 177 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : form work. 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 178 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 179 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 180 Providing and fixing SWR uPVC pipes (Type-B) confirming to IS 13592 : 1992 complete with all fittingse.g. plain or door bends, junctions, cowls, offsets, access pieces etc. jointing with rubber rings and solvent cement including fixing the pipes on wall face with galvanized iron holder bat clamps or suspended below ceiling with galvanized iron hangers/supports and fasteners all as approved by the engineer in charge including Cutting holes inwalls, floors excavation, refilling and disposal of surplus earth wherever required and making good . The rates shall be inclusive of painting of all supports and clamps with a coat of red oxide primer and two or morecoats of synthetic enamel paint of approved colour and Qualitytogivean even shade including surface preparation.(Sample ofholder bat clamps,hangers / supports to be approved by the Engineer-in-Charge.) 181 110 mm OD 182 Providing and fixinguPVC agricultural pipes conforming to IS:4985 (6 kg/sqcm) including all fittings, e.g. couplings, tees, bends, reducers and screwedadoptors jointing with solvent cement joint as per manufacturers recommendations. [for Waste Connections Pipes] 183 40 mm OD 184 63 mm OD 185 Providing and fixing uPVCP-Trap with extension piece including setting with cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 hand stone ballast 20 MM nominal size) the inlet from floor level to trap rim to be grouted and cemented neat manner including cutting and making good the floor & wall wherever requiredcomplete in all respects 186 110 mm inlet and 110 mm outlet. 187 Providing and fixing in position 110x63 mm OD uPVC reducing elbow including fix to floor with cement mortar. 188 Providing and fixing 110 mm OD uPVC inlet fitting/ Extension Piece with 2 or 3 inletsof 40 to 63 mm OD, fixed to uPVC trap with solvent cement joint and set in cement concrete as per drawing complete. 189 Providing and fixinguPVC agricultural pipes conforming to IS:4985 (6 kg/sqcm) including all fittings, e.g. couplings, tees, bends, reducers and screwedadoptors jointing with solvent cement joint as per manufacturers recommendations. [for Rain Water Pipes] 190 160 mm OD 191 110 mm OD 192 Providing and fixing of GI clamps with EPDM rubber lining Zinc plated for support of vertical rain water pipes, embedded in walls with anchor fastner etc. including cost of cutting holes and making good the walls complete in all respects. 193 For 100 mm dia Pipe 194 For 160 mm OD Pipe 195 Providing and fixing in position 125x125 mm stainless steel grating for floor trap/floor drain including fix to floor with cement mortar. 196 Water Supply System 197 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 198 Concealed work including cutting chases and making good the walls etc. 199 20 mm nominal outer dia .Pipes. 200 25 mm nominal outer dia .Pipes. 201 32 mm nominal outer dia .Pipes. 202 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 203 Internal work - Exposed on wall 204 20 mm dia nominal bore 205 25 mm dia nominal bore 206 32 mm dia nominal bore 207 40 mm dia nominal bore 208 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 209 20 mm dia nominal bore 210 25 mm dia nominal bore 211 32 mm dia nominal bore 212 40 mm dia nominal bore 213 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 214 20 mm dia nominal bore 215 25 mm dia nominal bore 216 32 mm dia nominal bore 217 40 mm dia nominal bore 218 Providing and fixing forged brass ball valve of brass body with hard chrome plated steel ball inside PTFE (Teflon) seat & ring with chrome plated centre handle with female BSP threads complete in all respects. 219 20 mm nominal bore 220 25 mm nominal bore 221 32 mm nominal bore 222 40 mm nominal bore 223 Providing and fixing Thermoflex or Kaiflex thermal insulation tubing a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification. 224 6 mm thick (Concealed Pipes) 225 For 20 mm dia Pipe 226 Providing and fixing forged brass single acting air release valve with screwed inlet 25 mm dia. 227 Providing and fixing threaded end brass digital water meter complete in all respect. 228 32 mm dia. 229 Providing and fixing of Single phase electrical actuator operated wafer type rubber lined butterfly valve with by pass arrangement as per drawing attached including level controller, 3 nos. normal butter fly valves,necessary control and Power cables ( Maximum 10 M. Length of each type) and control panel installed on OH tank filling line near the tanks complete in all respects. 230 32 mm dia. 231 Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. 232 Sewerage System 233 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 234 All kinds of soil 235 Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m. 236 All kinds of soil 237 Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. 238 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 239 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : For Bed Concrete of Sewer Lines. 240 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) 241 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 242 180x150 mm size P type 243 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 244 Providing, laying and jointing HDPE Double Wall Coil (DWC) SN-8 Grade pipes confirming to IS: 16098including all fittings wherever required e.g., tees, bends of any degree, couplings, adapters, plugs, unions etc. and jointing as manufacturer recommondation etc. including testing of joints etc. complete. 245 150 mm dia. 246 200 mm dia. 247 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 248 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 249 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 250 Extra for depth for manholes : 251 Size 90x80 cm 252 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 253 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 254 Part-C (Fire Fighting System) 255 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) 256 Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 257 Suitable HP squirell cage induction motor TEFC typesuitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325. 258 M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. 259 Suitable cement concrete foundation duly plastered and with anti vibration pads. 260 450 LPM at 35 m Head 261 Providing laying, testing & commissioning of C class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 262 100 mm dia. 263 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 264 25 mm dia 265 80 mm dia 266 100 mm dia 267 Providing, laying, testing & commissioning of B class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 268 80 mm dia. 269 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : 270 Single headed Stainless steel 271 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts,washers, gaskets conforming to IS 13095 of following sizes as required : 272 80 mm dia 273 100 mm dia 274 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 275 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : 276 100 mm dia 277 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 278 100 mm dia 279 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : 280 Stainless Steel (Grade 304) 281 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 282 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 283 20 mm nominal internal dia gun metal globe valve & nozzle. 284 Drum and brackets for fixing the equipmets on wall. 285 Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 286 40 m 287 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable fornstantaneous connection to interconnect hose pipe coupling as required : 288 Stainless Steel (Grade 304) 289 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 290 2 way - 100 mm dia M.S. Pipe 291 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 292 Providing and fixing MS partly glazed single/double hung lockable shutter fabricated from MS section as required with5 mm thick glass for fire station complete including stove enamelled painting of door and frame and words Fire Hydrant written on glass, suitable to accommodate 2 Hydrant landing valves, 1 fire hose reel, 2 nos.15m long 63 mm dia hose,1-branch pipe, 1no. fire mans axe, fire extiguishers 2 nos, including suitably mounted on a raisedmasonry platform as required. (Approx.size 0.90 m x 2.1m ) 293 Providing and fixing dial type pressure gauge with isolation cock and pipe at hydrant station. Dial diameter 100 mm caliberation, 0-15 kg 294 Providing andfixing resilient rubber neoprene lined single archvibration eliminators with unit control suitable for raw water upto 450C temperature workingpressure 25 kg andtestpressure 37.5 kg/cm2. 295 100 mm dia 296 Design, manufacture, supplying,fixing in position, testing and commissioning of the following front operated cubicle type, front access 2mm thick mild steel sheet, free standing, dust and vermin proof, switchboard with IP42 protection with hinged and lockable doors complete with interconnections, tinned copper crimping lugs, bonding to earth and painting, suitable for use at 415 volts, 3 phase 4 wire 50 Hz system and suitable for a fault level of 25 MVA symmetricalat 415 volts. 297 MCC for Fire Fighting Pumps at Terrace 298 INCOMING: 299 a) One 100 amp. TP +NL M.C.C.B. with rotary handle of breaking capacity 25 KA 300 b) One-Volt Meter (0-500 V) with selector switch 301 c) One Set indicating lamps 302 BUS BARS OUTGOING 303 a) 100 Amp TPN BUS BAR (Aluminium). 304 b) One - 63 Amp.TP +NL M.C.C.B. with rotary handle of breaking capacity 35KA 305 c) One FullyAutomatic D.O.L Starter suitable for Jockey Pump Motor 15 KW with over loadrelay,timer push buttons and Auto/Manual selector switch 306 d) One panel type Amp. meters onefor each motor with ASS. CTS etc. 307 e) One sets of On/Off - neon indicating lamp. 308 i) All interconnecting power &control wires/cables suitable size within thepanel andfrom panel to motors , pressure switches, level switches, cable Tray, pipes etc. includingbrass glands terminationwithin fire pump house and earthing as per specifications. 309 Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. 310 Capacity 4.5 Kg. 311 Providing and fixing ABC Powder type fire extinguishers consisting of welded M.S. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. 312 Capacity 6.0 Kg. 313 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 314 20 mm 315 25 mm 316 32 mm 317 FOR TV & TELEPHONE 318 Supply and fixing of following sizes of 25mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 319 Supply and fixing of following sizes of 32mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Uttar Pradesh View Result →
46.
Drinking Water Supply and Sanitation #9443546 Technical Bid
tender for Operation And Maintenance Of Jhansi Augmentation Water Supply Scheme 110 Mld And Jhansi Babina Water Supply Scheme 45 Mld Operation And Maintenance Of Jhansi Augmentation Water Supply Scheme 110 Mld And Jhansi Babina Water Supply Scheme 45 Mld For 1 Year The Scope Includes Oandm Of Intake Works Raw Water Mains Wtp Clear Water Mains And Other Ancillary Components, 1 Part-A (Civil work) 2 Skilled Operating Staff for Operation and Watch & Ward of 45 mld and 110 mld WTP 3 Providing of skilled operating stafffor opening and controllingsluice valve at CP tank (Head work Matateela ) in three shift at 45 MLD02 in each shift 4 1st shift(02 nos in each shift@ Rs 420 each) 5 2 nd shift(02 nos in each shift@ Rs 420 each) 6 3rd shift(02 nos in each shift@ Rs 420 each) 7 Providing of Skilled Petroling staff for Raw Water GravityMain pipe lineMatateela head work toBabina wtp - 20.0 km approx (1x3= 3 for 365 days @ Rs 420 each for 8 hours foreach shift) 8 Clear Water GravityMainBabina to Elite CircleJhansi 27.50 km approx(1x3= 4 for 365 days @ Rs 420 each for 8 hours foreach shift) 9 Providing of skilled operating stafffor Back wash operatingsluice valve,air sluice valve,in three shift at WTP 45 MLD plant(2 Nosin each shift x 3= 6 nos for 365 days=2190 nos) 8 hours foreach shift 10 Providing of skilled operating stafffor Back wash operatingsluice valve,air sluice valve,in three shift at WTP 110 MLD plant (2 Nosin each shift x 3= 6 nos for 365 days=2190 nos) 8 hours foreach shift 11 Providing of Skill stafffor maintinance of Chlorinator plant and PAC Doasing Machine works at 45 mldWater Tretment Plant (1 Nosin each shift x 3= 3 nos for 365 days=1095 nos) 8 hours foreach shift 12 Providing of Skill stafffor maintinance of Chlorinator plant and PAC Doasing Machine works at 110 mldWater Tretment Plant (1 Nosin each shift x 3= 3 nos for 365 days=1095 nos) 8 hours for each shift 13 CleaningofAlgae&othersuspendedmaterialfromInletChannelscreem , CLF , filter bed , settle water channelbymanuallabourandDisposalofAlgae &other suspended material from Inlet Channel to suitable place With in 8 km for 45 mld .(2x365 days=730 ) 8 hours foreach shift 14 CleaningofAlgae&othersuspendedmaterialfromInletChannelscreem , CLF , filter bed , settle water channelbymanuallabourandDisposalofAlgae &other suspended material from Inlet Channel to suitable place With in 8 km for 110 mld ..(2x365 days=730 ) 8 hours foreach shift 15 Horticulture works at Head Work (Matateela) and water treatment plant Campus Babina and other related works for45 mld and 110 mld WTP 16 Maintenance of the entire garden features in the garden area i.e. feeding of water,lawn trees, shrubs, hedge, flower beds, creepers etc. including hoeing, pruning replacement of plants gap filling, watering, mowing of lawn, clipping of hedge, removal of garden waste, applyinginsecticide,pescticide,fertilizer&Manures per month including all T&P as per the direction of ingineer incharge 17 Operation & Maintenance of Laboratory 18 Providing Lab Technicion/chemist (MSC Qualified) for Water test and maintain quality of dinking water as per CPHEO GUDE of turbidity, PH Value of water, Dosing of PAC, Jar test, Chlorine (Pre and Post) etc. at 45 MLD. WTP and 110MLD. WTP at BABINA . (1x 365 Days = 365 days) 19 Providing of labour for collection of water sample from bulk consumer located at different location weekly (2 nos x 4nos x12months = 96 days 20 Providing of labour for water meater reading and distribution of water bills for bulk consumer located at different location weekly (4 nox12 = 48 days) 21 Providing of labour for water meater readinglocated at Bijoli(2 no x365 days = 730 Nos) 22 Supply and installation of Laboratorary Equipment as per latest modle and specification including transportation,fright charges, loading and unloading complete asthe direction of engineer incharge complete . 23 Hot air oven 60 Lt (Make - Lefco India, Thermo Fisher) 24 Auto Clave 50 L(Make - Lefco India, Thermo Fisher) 25 Incubator 112 L (Make - Lefco India, Thermo Fisher) 26 Jar floculator (Make - Lefco India, Thermo Fisher) 27 Digital Balance Up to fourth decimal place(Make-Dhona,) 28 Digital Burette (Thermo Fisher) 29 Fluoride Ion Meter (Make -Thermo Fisher) 30 Ph meter(Make -Thermo Fisher) 31 Conductivity Meter(Make -Thermo Fisher) 32 Turbidity meter(Make -Hach) 33 Double Distillation Apparatus (Make -Borosil) 34 Filtration Assembly with Vacume pump (Make -Borosil) 35 UV Double Beam Spectrophotometer LI126 (Make Elico,Thermo Fisher) 36 UV Leminar air flow (Make - Lefco India, Thermo Fisher) 37 Water Bath 12 holes 38 Bunsen Electric Hot palte 10x12 inch ractangular 39 Refrigerator (LG 408 Lt frost free double door 3 star convertible Modle No- GLT412VESX) 40 Flume Hud (Make - Lefco India, Thermo Fisher) 41 Glasswares 42 Flask flat Bottom -1000ml Borosil with NABL 43 Flask Conical -250ml,Borosil with NABL 44 Flask Conical -100ml Borosilwith NABL 45 Flask Volumetric -1000ml BorosilClass A with NABL 46 Flask Volumetric -500ml BorosilClass A with NABL 47 Flask Volumetric-250ml BorosilClass A with NABL 48 Flask Volumetric -100ml BorosilClass A with NABL 49 Flask Volumetric - 50ml Borosil Class A with NABL 50 Pipettes Volumetric -50ml BorosilClass A with NABL 51 Pipettes Volumetric-25 ml BorosilClass A with NABL 52 Pipettes Volumetric -20 ml Borosil Class A with NABL 53 Pipettes Volumetric- 10 ml Borosil Class A with NABL 54 Pipettes Volumetric -5 ml BorosilClass A with NABL 55 Pipettes Graduated-25 ml BorosilClass A with NABL 56 Pipettes Graduated -10 ml BorosilClass A with NABL 57 Pipettes Graduated -5ml BorosilClass A with NABL 58 Measuring Cylinder -250ml Borosil Class A with NABL 59 Measuring Cylinder -100ml BorosilClass A with NABL 60 Measuring Cylinder -50ml BorosilClass A with NABL 61 Burette- 50ml BorosilClass A with NABL 62 Burette-25ml Borosil Class A with NABL 63 Reagent Bottle -2000ml Borosilwith NABL 64 Reagent Bottle -1000ml Borosilwith NABL 65 Reagent Bottle -500ml Borosilwith NABL 66 Reagent Bottle -250ml Borosilwith NABL 67 Reagent Bottle -125ml Borosilwith NABL 68 Test Tube Size -150x18mm Borosilwith NABL 69 Test Tube Size- 125x15mm Borosil with NABL 70 Funnel Size -7.5 cm Borosil with NABL 71 Beaker -1000ml Borosilwith NABL 72 Beaker -500ml Borosilwith NABL 73 Beaker -250ml Borosilwith NABL 74 Beaker -100ml Borosilwith NABL 75 Porcelin Basin white with NABL 76 Nesseler Cylinder -100ml Borosil with NABL 77 Nesseler Cylinder -50ml Borosil with NABL 78 Petridish Size- 100mm Borosilwith NABL 79 Fermantation Tube Borosilwith NABL 80 Watch glass Borosilwith NABL 81 Burette stand Poly lab with NABL 82 Desiccator -150 mm Borosylicate with NABL 83 Chemicals 84 Silver Nitrate AR (Merck)-25 gram 85 Potassium Chromate AR (Merck)-500 gram 86 EDTA disodium AR (Merck)-100 gram 87 Eriochrome Black T AR (Merck)-25 gram 88 Magnesium Sulphate AR(Merck)-500 gram 89 Ammonium Hydroxide 25% AR (Merck)-2.5 lit 90 Murexide (Ammonium Purpurate) AR (Merck)-5 gram 91 Ethylene Glycol (Absolute) AR (Merck)-500 gram 92 Sodium Chloride AR (Merck)-500 gram 93 Phenolpthalein Indicator AR (Merck)-125 ml 94 Methyl Orange AR (Merck)-25 gram 95 CDTA AR (CDH) -100 gram 96 Hydrochloric Acid AR (Merck)-2.5 lit 97 Sulfuric Acid 98% AR (Merck)-2.5 lit 98 Acetic Acid glacial AR (Merck)-2.5 lit 99 Ammonium AcetateAR (Merck)-500 gram 100 Hydroxylamine Hydrochloride AR (Merck)-250 gram 101 1-10 Phenanthroline AR (Merck)-5 gram 102 Ethyl Alcohal AR (Merck)-500 ml 103 Barium Chloride AR (Merck)-500 gram 104 Glycerol AR (Merck)-500 ml-500 gram 105 Potassium Permanganate AR (Merck) 106 Sodium Hydroxide AR (Merck)-500 gram 107 Beef Extract (Merck)-500 gram 108 Lactose (Merck)-500 gram 109 Agar - Agar (Bact.) (Renkam)-500 gram 110 Sodium Chloride (Merck)-500 gram 111 Peptone Bacteriological(Renkam)-500 gram 112 Sodium Tourocholate (Loba)-500 gram 113 Nuteral Red Indicator (Fisher)-25 gram 114 Sodium Hydroxide (Merck)-500 gram 115 Magnese Sulfate (Merck)-500gram 116 Extran (Merck) MA01-500ml 117 Ortho - Tolidine Solution (Qualigen)-500 ml 118 Sodium Azide (Merck)-100gram 119 Strach-500 gram 120 Providing on Sweeper for cleaning of road, drains, quarters and other units at Water treatment plant Campus at babina (3 Nos x 365 Daysat WTP Campus) 121 Providing on Sweeper for cleaning of road, drains, quarters and other units atmatateela Campus head water works (1 No x 365 Days= 365days) 122 Providing ofhelper for cwr Jhansi for watch and ward of bulk consumer maintinace purpose in three shift(5nos x 365 days = 1825 Nos) 123 Bitumen roadTYPE AConstruction of bitumen road as per UPPWD specification including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-GSB G-1 (One coat) (90-40 mm) = 12.5 cmG -2 (one coat) (45-63 mm) = 7.5 cmG - 3 (one coat) (22.5 - 53 mm) = 7.5 cmBM (One coat)= 7.5 cmSDBC (One coat)= 2.5 cm 124 TYPE BConstruction of bitumen road as per UPPWD specification including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-Bitumen Road (SDBC + Tack coat)SDBC (One coat)= 2.5 cmTack coat with bituminous emulsion (MS)= 0.25 kg/sqm(30% consider for over dismantling of existing road) 125 Cement Concrete Road 126 C.C. Interlocking Tiles Road Type AConstruction of 80 mm tihck C.C. Interlocking Tile road including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-PCC = 100 mm,1:4:8 (cement, coarse sand & stone ballast of 20-40 mm)Sand= 50 mm thick local sand lair for preparation of surfaceTiles = 100% new 127 Filter Media for 110 mld & 45 mld 128 Supply & fixing as per specification provided by department of Filter media for Filter beds effective size of 0.45mm to 0.70 mm of 80 CM height over graded gravel as per drawingattatched on tender document. 129 Supply of supporting media gravel of size 3 mm to 6 mm of 20 cm heightas per drawingattatched on tender document. 130 Removal of old filtration media sand and supporting media gravel from the filter bed and filling the new filtration media sand and supporting media gravel as per direction of site incharge including supply of labour material and T&P etc complete 131 (Chemical for 45 mld and 110 mld WTP ) 132 Supply of Bleaching powerat site of 110 MLD and 45 MLD W.T.P Babina including carting , loading , unloading etc. complete. 133 Lumpsump provision for repairing of leakage at different locationin differentdia of Raw water and Clear Water gravity main pipelinein the water supply system located fron matateela to jhansi (including Carting of material from central store such hiring of pump set, deisel, jointing material, cememt sand,Lead wool, cico no -2 etc which is required at site)For 45 mld and 110 mld WTP 134 For 110 mld WTP - 1400 mm dia PSCpipe in Gravity main ( Running pipe line )Matateela to Babina - 20.0 km approx 135 For 110 mld WTP - 1300 mmdia PSCpipe in Gravity main ( Running pipe line ) Babina to Hansri 22.50 km approx 136 For 110mld WTP - 1200 mm dia PSCpipe in Gravity main ( Running pipe line ) Hansri to Jal nigam Colony Jhansi5.0 km approx 137 For 45 mld WTP - 42 dia PSCpipe in Gravity main ( Running pipe line ) Matateela to Babina - 20.0 km approx 138 For 45 mld WTP - 33 dia PSCpipe in Gravity main ( Running pipe line ) Babina to MES Jhansi 24.0 km approx 139 For 45 mld WTP - 21 dia PSCpipe in Gravity main ( Running pipe line ) Babina to MES Jhansi 1000 m approx 140 For 110 mld WTP - 250 dia ACpipe in Gravity main ( Running pipe line )sale tax road to Medical college Jhansi 7 km approx 141 For 110 mld WTP - 200 dia DIpipe in Gravity main ( Running pipe line ) CWR to IGFRI Campus Jhansi 9.0 km approx 142 For 110 mld WTP - 150&125 mm dia DIpipe in Gravity main ( Running pipe line ) CWR to Army aviation Jhansi 5.0 km approx 143 Part B (E & M works) 144 E&M Operation and Maintenance Staff at Head Works Matatila 145 Providing of Skilled eletrician for maintinance of electrical equipments and other related eletrical works atMatatila head works01 in each shift 8 hours 146 1st shift 147 2 nd shift 148 3rd shift 149 Providing of Skilled mechanic for maintinance of mechanical equipments and other related eletrical works atMatatila head works01 in each shift 8 hours 150 1st shift 151 2 nd shift 152 3rd shift 153 Providing of Skilled operator for operation ofpumps , DG set and associated mechanical & electrical equipmentsatMatatila head works01 in each shift 8 hours 154 1st shift 155 2 nd shift 156 3rd shift 157 Providing of Skilled helper for electrician and mechanicatMatatila head works01 in each shift 8 hours 158 1st shift 159 2 nd shift 160 3rd shift 161 Routine, periodically and breakdown maintinance of all equipments, associated accessories installed at verious units at Matatila head works including supply,opening and refixing,fright charges, transportation , loading unloadingall T&P etc. complete as per the direction of engineer incharge. 162 Matatila Head works 163 Routine maintinance and servicing of 320 KVA D G set including all necessary spares, oil, Filters, Diode and lubricant as per norms 164 Repairing and Overhauling of 650 LPS discharge kirlosker make pumps with following works. Model MF 40-45 165 Dismantling, carting and re-installation of pump set including testing on load at site with all labour and T&P 166 Supply and fixing of new ball bearing-6415 and oil seal. 167 Supply and fixing of new thrust bearing-51320M 168 Fabrication, Supply and fixing of fully balanced new pump shaft made of SS 410 as per sample. 169 Reconditioning of pump shaft with rematling, machining and balancing complete in all respect. 170 Reconditioning of pump impeller with rematling, machining and balancing complete in all respect. 171 supply and fixing of New impeller for pump as per sample and zise 172 Supply and fixing of new shaft sleeve, chuck nut made of SS 410 as per sample. 173 Supply and filling of lubricating oil in every 6 months 174 Supply and fixing of new Fastners 175 Supply and filling of Glande packing as per size and sample. 176 Supply and fixing of new Glande plate with stud and nut. 177 Repairing & maintenance of kirloskar make induction motor with following works 178 Dismantling, carting and re-installation of motor including testing on load at site with all labour and T&P 179 Rewinding of 75 KW, 736 rpm, 3 Phase induction motor with F-class insulated copper wire, nomax paper, sleeves, varnishing etc. complete with all material and T&P. 180 Rewinding of 55 KW, 736 rpm, 3 Phase induction motor with F-class insulated copper wire, nomax paper, sleeves, varnishing etc. complete with all material and T&P. 181 Supply and fixing of new ball bearing-NU318C3 182 Supply and fixing of new ball bearing-6318C3 183 Fabrication, Supply and fixing of new rotar shaft as per sample and material. 184 Reconditioning of rotar shaft with rematling, machining and balancing complete in all respect. 185 Reconditioning of bearing housing with rematling, machining and balancing complete in all respect. 186 Routine Greasing of induction motor bearings with high temprature Jelly grease in every 30 days intervals 187 Supply and fixing of new Fastners 188 Supply and fitting of motor connection plate with suitable size of lugs as per sample etc. complete. 189 Repairing and Maintenance of 600mm size sluice valve with following works 190 Dismantling, carting and re-installation of sluice valve with all labour and T&P 191 Supply and fixing of spendle for sluice valve made of SS 304 as per size and sample 192 Supply and fixing of Bush for sluice valve made of gun metal as per size and sample 193 Supply and fixing of Disc and body sheet for sluice valve made of gun metal complete with all maching and finishing 194 Supply and fixing of Glande plate with Studs 600mm size sluice valve as per sample 195 Supply and filling of Glande packing as per size and sample 196 Repairing and rewinding of exhaust fan size 450mm with replacing of barings etc. complete. 197 Repairing and rewinding of exhaust fan size 600mm with replacing of barings etc. complete. 198 Complete wiring of H.T panel room with 1.5 and 2.5 Sq.mm multi strands copper conductor wire PVC insulated including Caping casing,power board, 5 Amp. switch and socket as per direction of engineer incharge with all labour, T&P and materials 199 Supply and fixing of dial gauge type pressure guage with cock at outlet of pump set 200 Servicing and overhauling of HOT crane including replacement of warmout parts with all labour and T&P 201 Routine Servicing of HT Panel 202 supply & fixing of Lov joy coupling for pumpset model C-2955 203 supply and fixing of power & control card for 110 KW Soft starter as per sample 204 Maintinance of all campus lighting, Head work Matatila andother building etc. includingsupply, fixing fright charges all T&P all complete as per the direction of engineer incharge (Brand name Syska, Philips,Bajaj,Havells) 205 LED Bulb 206 Supply and Fixing of 9 Watt 207 Supply and Fixing of 20 Watt 208 Supply and Fixing of 30 Watt 209 Supply and Fixing of 40 Watt 210 Supply and Fixing of 50 Watt 211 LED Tube light 212 Supply and Fixing of 22 Watt 213 Supply and Fixing of 36 Watt 214 LED StreetFlood light 215 Supply and Fixing of 50 Watt 216 Supply and Fixing of 100 Watt 217 Supply and Fixing of 1200mm size 218 E&M Operation and Maintenance Staff at 110 MLD & 45 MLD WTP Babina 219 Providing of Skilled eletrician for maintinance of electrical equipments and other related eletrical works at110 MLD & 45 MLD WTP Babina01 in each shift 8 hours 220 1st shift 221 2 nd shift 222 3rd shift 223 Providing of Skilled mechanic for maintinance of mechanical equipments and other related eletrical works at110 MLD & 45 MLD WTP Babina 01 in each shift 8 hours 224 1st shift 225 2 nd shift 226 3rd shift 227 Providing of Skilled operator for operation ofpumps , DG set and associated mechanical & electrical equipmentsat 110 MLD & 45 MLD WTP Babina01 in each shift 8 hours 228 1st shift 229 2 nd shift 230 3rd shift 231 Providing of Skilled helper for electrician and mechanic110 MLD & 45 MLD WTP Babina02 in 1st shift and 01 in other shifts 8 hours 232 1st shift (02Nos@Rs 350/- = Rs 700/-) 233 2 nd shift 234 3rd shift 235 Routine, periodically and breakdown maintinance of all equipments, associated accessories installed at verious units of 45 mld 110 mld WTP including supply,opening and refixing,fright charges, transportation , loading unloadingall T&P etc. complete as per the direction of engineer incharge. 236 110 MLD & 45 MLD WTP Babina 237 Rewinding and repairing of flash mixture induction motor having capacity of 5 hp, 3 phase with replacement of bearingsincluding Loading-unloading, Transportation etc. complete with testing on load 238 Repairing and overhauling of Grear box of flash mixture including replacement of warmout parts, bearings, Dismentaling, Loading, Carting and reinstallation etc. complete with testing on load 239 Repairing and Overhauling of Sluice Gate 1100x1300 mm size at flash mixer with following works 240 Dismentaling, carting, refitting and testing with all labour and T&P required at site 241 Fabrication, Supply and fixing of new threaded spindle shaft made of SS:316 as per size and sample 242 Fabrication, Supply and fixing of new bush made of Gun metal and wage piece as per size and sample 243 Fabrication, Supply and fixing of new fix and moving sheet made of Gun metal as per size and sample 244 Repairing and Overhauling of Sluice gate 1300x1500 mm size with following works :- 245 Dismentaling, carting, refitting and testing with all labour and T&P required at site 246 Fabrication, Supply and fixing of new threaded spindle shaft made of SS:316 as per size and sample 247 Fabrication, Supply and fixing of new bush made of Gun metal and wage piece as per size and sample 248 Fabrication, Supply and fixing of new fix and moving sheet made of Gun metal as per size and sample 249 Filter Bed No-8 @13.75 mld each 250 Repairing and Overhauling of Sluice Gate 450x450 mm size at Filter Bed Inlet with following works :- 251 Dismentaling, carting, refitting and testing with all labour and T&P required at site 252 Fabrication, Supply and fixing of new threaded spindle shaft made of SS:316 as per size and sample 253 Fabrication, Supply and fixing of new bush made of Gun metal and wage piece as per size and sample 254 Fabrication, Supply and fixing of new fix and moving sheet made of Gun metal as per size and sample 255 Repairing and Overhauling of Sluice Gate 600x450 mm size at Backwash Outlet with following works :- 256 Dismentaling, carting, refitting and testing with all labour and T&P required at site 257 Fabrication, Supply and fixing of new threaded spindle shaft made of SS:316 as per size and sample 258 Fabrication, Supply and fixing of new bush made of Gun metal and wage piece as per size and sample 259 Fabrication, Supply and fixing of new fix and moving sheet made of Gun metal as per size and sample 260 Repairing and Overhauling of 500mm dia size sluice valve at Backwash water inlet with following works. 261 Dismantling, carting and re-installation of sluice valve with all labour and T&P 262 Supply and fixing of spendle for sluice valve made of SS 316 as per size and sample 263 Supply and fixing of Bush for sluice valve made of gun metal as per size and sample 264 Supply and fixing of Disc and body sheet for sluice valve made of gun metal complete with all maching and finishing 265 Supply and fixing of Glande plate with Studs as per sample 266 Supply and filling of Glande packing as per size and sample 267 Repairing and Maintenance of 200mm dia size Sluice valve at Backwash Air Inlet with following works :- 268 Dismantling, carting and re-installation of sluice valve with all labour and T&P 269 Supply and fixing of spendle for sluice valve made of SS 316 as per size and sample 270 Supply and fixing of Bush for sluice valve made of gun metal as per size and sample 271 Supply and fixing of Disc and body sheet for sluice valve made of gun metal complete with all maching and finishing 272 Supply and fixing of Glande plate with Studs as per sample 273 Supply and filling of Glande packing as per size and sample 274 Repairing and Maintenance of 300mm dia size Sluice valve at Filter Water Outlet with following works :- 275 Dismantling, carting and re-installation of sluice valve with all labour and T&P 276 Supply and fixing of spendle for sluice valve made of SS 304 as per size and sample 277 Supply and fixing of Bush for sluice valve made of gun metal as per size and sample 278 Supply and fixing of Disc and body sheet for sluice valve made of gun metal complete with all maching and finishing 279 Supply and fixing of Glande plate with Studs 600mm size sluice valve as per sample 280 Supply and filling of Glande packing as per size and sample 281 Repairing and Maintenance of 100mm dia size Sluice valve for Chamber cleaning with following works :- 282 Dismantling, carting and re-installation of sluice valve with all labour and T&P 283 Supply and fixing of spendle for sluice valve made of SS 304 as per size and sample 284 Supply and fixing of Bush for sluice valve made of gun metal as per size and sample 285 Supply and fixing of Disc and body sheet for sluice valve made of gun metal complete with all maching and finishing 286 Supply and fixing of Glande plate with Studs 600mm size sluice valve as per sample 287 Supply and filling of Glande packing as per size and sample 288 Clarifloculator -1&2 289 Rewinding and repairing of 5 hp motor 3 phaseInduction motor including replacement of bearings, Dismentaling, Transportation, Refitting with testing on load 290 Repairing and Overhaulig of Gear box coupled with 5 H.P. Induction motor including replacement of warmout parts, Dismentaling, Loading, Carting and reinstallation etc. complete with testing on load 291 Repairing of Desludging Valve 300 mm dia Weidge Piece brass & Gun metal 292 Repairing of Desludging Valve 300 mm dia Spendle brass & Gun metal 293 Tefloan CLF wheel 294 Repairing and Overhauling of Swam make Air Blower with following works :- 295 Dismantling, carting and re-installation of Air blower with all labour and T&P 296 Repairing and Overhualing of 2500 cum/hrs capacity Air Blower including replacement of bearings, damaged parts complete with testing on load 297 Rewinding and repairing of 60 hp, 3 Phase induction motor of air blower including Dismentaling, Loading, Carting and reinstallation etc. complete with testing on load 298 Replacement of bearing no. 6313 299 Repairing and Overhauling of 483.33 LPS discharge kirlosker make backwash pumps with following works. Model No. 35-40 300 Dismantling, carting and re-installation of pump set including testing on load at site with all labour and T&P 301 Supply and fixing of new ball bearing-6412 and oil seal. 302 Supply and fixing of new thrust bearing-51314M 303 Fabrication, Supply and fixing of fully balanced new pump shaft made of SS 410 as per sample. 304 Reconditioning of pump shaft with rematling, machining and balancing complete in all respect. 305 Reconditioning of pump impeller with rematling, machining and balancing complete in all respect. 306 Supply and fixing of new shaft sleeve, chuck nut made of SS 410 as per sample. 307 Supply and filling of lubricating oil in every 6 months 308 Supply and fixing of new Fastners 309 Supply and filling of Glande packing as per size and sample. 310 Supply and fixing of new Glande plate with stud and nut. 311 Repairing & maintenance of kirloskar make induction motor of 150 HPfor Backwash pump with following works 312 Dismantling, carting and re-installation of motor including testing on load at site with all labour and T&P 313 Rewinding of 110 KW / 150 HP, 980 rpm, 3 Phase induction motor with F-class insulated copper wire, nomax paper, sleeves, varnishing etc. complete with all material and T&P. 314 Supply and fixing of new ball bearing-NU319C3 315 Supply and fixing of new ball bearing-6319C3 316 Fabrication, Supply and fixing of new rotar shaft as per sample and material. 317 Reconditioning of rotar shaft with rematling, machining and balancing complete in all respect. 318 Reconditioning of bearing housing with rematling, machining and balancing complete in all respect. 319 Routine Greasing of induction motor bearings with high temprature Jelly grease in every 30 days intervals 320 Supply and fixing of new Fastners 321 Supply and fitting of motor connection plate with suitable size of lugs as per sample etc. complete. 322 Chlorine OHT feeded pump 323 Rewinding and repairing of 5 hp 3 Phase motor with F class insulated copper wire, nomax paper, glass lead etc. including Dismentaling, Loading, Carting and reinstallation etc. complete with testing on load 324 Repairing and Overhauling of 4.17 LPS, 18 mtr. head, 2900 RPM end suction horizontal centrifugal pump with replacement of bearings, reconditioning of pump shaft, bearing housing etc. complete including Dismentaling, Loading, Carting and reinstallation etc. complete with testing on load 325 Supply,, Installation,, Testing and commissioning of PAC Doasing pump 326 Repairing and rewinding of exhaust fan size 450mm with replacing of barings etc. complete. 327 45 mld WTP 328 Flash Mixture 329 Rewinding and repairing of flash mixture 7.5 hp mortor 3 phaseincluding Loading Transportation etc. complete with testing on load 330 Repairing and Overhauling of flash mixture Grear box with replacement of warmout parts including Dismentaling, Loading, Carting and reinstallation etc. complete with testing on load 331 Clarifloculator -1&2 332 Rewinding and repairing of gear fan motor 5 hp motor 3 phaseincluding Loading Transportation etc. complete with testing on load 333 Repairing of Gear box of gear fan motor including Dismentaling, Loading, Carting and reinstallation etc. complete with testing on load 334 Rewinding and repairing of main drive 5 hp motor 3 phaseincluding Loading Transportation etc. complete with testing on load 335 Repairing of Gear box of main drive including Dismentaling, Loading, Carting and reinstallation etc. complete with testing on load 336 Repairing of Desludging Valve 300 mm dia Weidge Piece brass & Gun metal 337 Repairing of Desludging Valve 300 mm dia Spendle brass & Gun metal 338 Tefloan CLF wheel 339 Filter Bed No-5 @ 9.0 mld each 340 Repairing and Overhauling of Sluice Gate 500x500 mm size at Backwash Outlet with following works :- 341 Dismentaling, carting, refitting and testing with all labour and T&P required at site 342 Fabrication, Supply and fixing of new threaded spindle shaft made of SS:316 as per size and sample 343 Fabrication, Supply and fixing of new bush made of Gun metal and wage piece as per size and sample 344 Fabrication, Supply and fixing of new fix and moving sheet made of Gun metal as per size and sample 345 Repairing and Overhauling of 500mm dia size sluice valve at Backwash water inlet with following works. 346 Dismantling, carting and re-installation of sluice valve with all labour and T&P 347 Supply and fixing of spendle for sluice valve made of SS 304 as per size and sample 348 Supply and fixing of Bush for sluice valve made of gun metal as per size and sample 349 Supply and fixing of Disc and body sheet for sluice valve made of gun metal complete with all maching and finishing 350 Supply and fixing of Glande plate with Studs as per sample 351 Supply and filling of Glande packing as per size and sample 352 Repairing and Maintenance of 300mm dia size Sluice valve at Filter Water Outlet with following works :- 353 Dismantling, carting and re-installation of sluice valve with all labour and T&P 354 Supply and fixing of spendle for sluice valve made of SS 304 as per size and sample 355 Supply and fixing of Bush for sluice valve made of gun metal as per size and sample 356 Supply and fixing of Disc and body sheet for sluice valve made of gun metal complete with all maching and finishing 357 Supply and fixing of Glande plate with Studs 600mm size sluice valve as per sample 358 Supply and filling of Glande packing as per size and sample 359 Repairing and Maintenance of 300mm dia size Sluice valve for Raw Water Inlet with following works :- 360 Dismantling, carting and re-installation of sluice valve with all labour and T&P 361 Supply and fixing of spendle for sluice valve made of SS 304 as per size and sample 362 Supply and fixing of Bush for sluice valve made of gun metal as per size and sample 363 Supply and fixing of Disc and body sheet for sluice valve made of gun metal complete with all maching and finishing 364 Supply and fixing of Glande plate with Studs 600mm size sluice valve as per sample 365 Supply and filling of Glande packing as per size and sample 366 Back Wash Pump motor 367 Rewinding and repairing of Back wash motor 15 hp motor 3 phaseincluding Loading Transportation etc. complete with testing on load 368 Repairing of Backwash pump of 15 hp including Dismentaling, Loading, Carting and reinstallation etc. complete with testing on load 369 Rewinding and repairing of Back wash motor 12.5 hp motor 3 phaseincluding Loading Transportation etc. complete with testing on load 370 Repairing of Backwash pump of 12.5 hp including Dismentaling, Loading, Carting and reinstallation etc. complete with testing on load 371 Repairing and rewinding of exhaust fan size 450mm with replacing of barings etc. complete. 372 Repairing and rewinding of Ceiling fan with replacing of barings etc. complete. 373 ForGardening, Colony and Block Supply 374 Rewinding and repairing of 7.5 hp 3 Phase motor including Dismentaling, Loading, Carting and reinstallation etc. complete with testing on load 375 Repairing of Backwash pump of 7.5 hp including Dismentaling, Loading, Carting and reinstallation etc. complete with testing on load 376 supply and fixing of power & control card for 110 KW Soft starter as per sample 377 supply and fixing of power & control card for 45 KW Soft starter as per sample 378 Repairing and overhauling ofgarvity feed type Chlorination system complete at 110 & 45 MLD WTP Babinacapacity complete with all required spare parts 379 Supply and fixing of variable friquency drive (VFD) panel with all protective devices suitable to operate 150 HP backwash pumping plant as per relevant IS code 380 Maintinance of all campus lighting, 45 mld 110 mld WTP Babina and laboratory house and other building etc. includingsupply, fixing fright charges all T&P all complete as per the direction of engineer incharge (Brand name Syrya, Syska, Philips,Bajaj,Havells) 381 LED Bulb 382 Supply and Fixing of 9 Watt 383 Supply and Fixing of 20 Watt 384 Supply and Fixing of 30 Watt 385 Supply and Fixing of 40 Watt 386 Supply and Fixing of 50 Watt 387 LED Tube light 388 Supply and Fixing of 22 Watt 389 Supply and Fixing of 36 Watt 390 LED StreetFlood light 391 Supply and Fixing of 50 Watt 392 Supply and Fixing of 100 Watt 393 Supply and Fixing of 1200mm size
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
47.
Housing Urban and Rular Development #9443208 Technical Bid
Tender For Renovation Work In The Existing Building Of Tb Ward At Medical College, At-Jhansi (U.P.), 1 Renovation Work in The Existing Building of TB Ward at Medical College, at-Jhansi (U.P.) 2 T.B. & CHEST DEPTT. BUILDING 3 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil 4 Cement concrete with 4 CM guage approved stone ballast approved coarse sand and cement in the proportion of 8:4:1 including supply of all material labour and tools and plants etc required for proper completion for the work. 5 R.C.C.Raft foundation and footingwithapproved stoneballast. (Using1:1.5:3Mix concrete) 6 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 7 R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in lighter beam excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. 8 R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in slab excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. 9 Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work(whennot includedin anover all rates )wroughttorequired shape as necessary including bending for proper completion of thework andincluding supply of steel itswastage bendhooks andauthorisedover lappingshallbe measured upto floor two level. 10 Mild steel or iron workofheavy sizes and sections suchas holding down bolts,holdfasttierods,gratings etc. ( when notincludedinan overall rates) wroughttorequiredfromincludingsupply ofsteel , bolts, nuts and wastages etc their fixing required for completion of the work 11 Providing And Fixing of g.i. tata sheet for shed including all laobur and material etc complete.(0.80mm thick) 12 Providing and laying of 8Omm interlockingconcrete block pavement laid in stone dust baso and tiI joint w;th fine sand. Joint filled after labting and dressing base including supply of att materiat, tabour, T&p etc required for proper comptetion of the work. 13 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade.Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture : (M.S. works). 14 Providing and fixing mineral fibre falseiling tiles at all heights of size595X595mm of approved texture, design and pattern. The tiles shouldhave Humidity Resistance (RH) of 99%, Light Reflectance ? 85%,Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance asper (BS 476 pt - 6 &7)in true horizontal level suspended on interlockingT-Grid of hot dipped all round galvanized iron section of 0.33 mm thick(galvanized @120 gsm) comprising of main T runners of 15x32 mm oflength 3000 mm, cross T of size 15x32mm of length 1200 mm andsecondary intermediate cross T of size 15x32 mm of length 600 mmto form grid module of size 600x600 mm suspended from ceiling usinggalvanized mild steel item (galvanised@80gsm) 50 mm long 8mmouter diameter M-6 dash fasteners, 6 mm diameter fully threadedhanger rod up to 1000 mm length and L-shape level adjuster of size85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’.The system should rest on periphery walls /partitions with the help ofGI perimeter wall angle of size24x24X3000 mm made of 0.40 mmthick sheet, to be fixed to the wall with help of plastic rawl plug at 450mm centre to centre & 40 mm long dry wall S.S. screws. The exposedbottom portion of all T-sections used in false ceiling support systemshall be pre-painted with polyester baked paint, for all heights. Thework shall be carried out as per specifications, drawings and as perdirections of the engineer-in-charge 15 Cast cement concrete door sills, chaukhals boundry posts, shclves and similar small work with cemenl, approved coa,sc sand and 2 cm. {3/4) g;ugc apr ov.d ston. batast in the proponaon ol 1 : 2 :4 , cxctuding supply of rernrorcemenr and rts brnding but rnclu.lin9 its fixing and binding thc same with 24 B.W.c.c.l_ bjnding wire, and including the cost ol binding wire, noutds and a[ orher,materials, labour and T&P eic requi.ed tor proper completion ol the work 16 Supply and fixing of 100 mm dla A.C down pipe complote with rose heads bends M.S Clamps 2.5 cm x 3 mm fixed to walls by 15 cm Long 6 mm dia nail and including repair of plaster pointing etc if damaged during fixing of the pipes including cost of all material labour, tools a d plant etc required for propcr completion of work.As ilemabove but for 150 mm dia PVC pipe 17 Supply and fixing of 100 mm dla A.C down pipe complote with rose heads bends M.S Clamps 2.5 cm x 3 mm fixed to walls by 15 cm Long 6 mm dia nail and including repair of plaster pointing etc if damaged during fixing of the pipes including cost of all material labour, tools a d plant etc required for propcr completion of work.As ilemabove but for 100 mm dia PVC pipe 18 Supply and fixing of 100 mm dla A.C down pipe complote with rose heads bends M.S Clamps 2.5 cm x 3 mm fixed to walls by 15 cm Long 6 mm dia nail and including repair of plaster pointing etc if damaged during fixing of the pipes including cost of all material labour, tools a d plant etc required for propcr completion of work.As ilemabove but for 75 mm dia PVC pipe 19 Supply and fixing of 100 mm dla A.C down pipe complote with rose heads bends M.S Clamps 2.5 cm x 3 mm fixed to walls by 15 cm Long 6 mm dia nail and including repair of plaster pointing etc if damaged during fixing of the pipes including cost of all material labour, tools a d plant etc required for propcr completion of work.As ilemabove but for 50 mm dia PVC pipe 20 Supplyand lixing of4 cm (1 1/2) rhick C p teek wood do and window shutters with panets oI haavy quality gatvanized iron wire gauge 2-5 mm. or 2 nm. or 1.5 nrnr (t/10 or 1/12 or 1/6 ioch) mesh orany oiher size wirh necessary beading, inctudjng supply and fixing of woodon cleals aod srops and including tiiirg and adjustment of hinges bolls, tocts, hanrlles, spring ard/or otier flthgs tul excluding Iheirsuppry and inctrrding two coats of black Japan oi alliron necessary. 21 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides 22 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) Ground Floor 23 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) Ground Floor 24 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand)Ground Floor 25 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) Ground Floor 26 12mm thick plaster in 1:3 on ceiling and soffitsof stairs upto floor two level.Ground Floor 27 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 28 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm Ground Floor 29 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm Ground Floor 30 Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade.Area of slab over 0.50 sqm Ground Floor 31 Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade.Ground Floor 32 Providing edge double moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite workGround Floor 33 Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm Ground Floor 34 Supply & fixing 6mm thick China white glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry, jointing and polishing complete, including supply of all materials labour and T & P etc required for proper completion of the work. Ground Floor 35 Providing & fixing ISI marked flush door shutters conforming IS: 2202 decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters(a) 35mm thick including ISI marked stainlesssteel butt hinges with necessary screws.Both side laminated. (i) Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) (ii)Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). (a) Single leaf 36 Angle iron Chaukhats 37 Z-section 38 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Internal wall surface) Ground Floor 39 Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm (Asian Paint or equivalent) Ground Floor 40 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.Ground Floor 41 Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. 42 Providing and fixing Stainless steel 304 grade sliding door bolts, of 16mmx250mm solidrod with required nuts, screws, keeper, etc. all itemto s.s. 304 grade only and supplied along with material test certificate. (OZ-ALD-01(16x250mm) 43 Providing and fixing Stainless steel 304 gradetower bolts (barrel and plate type) with required nuts, screws, keeper, etc. all itemto s.s. 304 grade only and supplied along with material test certificate.(a) 300 mm x 10mm . 44 (b) 250 mm x 10mm . 45 Providing and fixing Stainless steel 304 grade handles with platefixed with S.S. screws,etc. complete of size 10mm 125mm all itemto s.s. 304 grade only and supplied along with material test certificate. 46 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqmof cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface withtrowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water fora minimum period of two weeks for curing and for final test. All above 47 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes 48 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. 49 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. 50 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar 51 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar 52 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead.Of area beyond 3 sq. metres : 53 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 54 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm 55 Disposal of malba 56 Boundary wall with 1.80 Mtr. 57 SITC OF 1.5 TR TYPE HIWALL SPLIT AC ONE TO ONE ( ONLY COOLING INVERTER TYPE ) 5 STAR , RATED , 1 PHASE COOLING ONLY, WITH WIRELESS REMOTE 58 INTERNAL W/S AND SANITATION (TB BLOCK-2) 59 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid 60 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 61 Providing and fixing Stainless Steel AISI 304(18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40mm including painting of fittings and brackets, cutting and making good the walls wherrerever required. Kitchen sink with drain board510x1040 mm bowl depth 250mm 62 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe40 mm dia 63 Providing and fixing uplasticised PVC connection pipe with brass unions : 30 cm length 15 mm nominal bore 64 45 cm length 15 mm nominal bore 65 Providing and fixing CP Brass 32mm/40mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 66 Providing and fixing 600 x 450mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete in all respect. 67 Providing and fixing toilet paper holder. C.P. brass 68 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 69 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 70 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore 71 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards andweighing not less than 690 gms. 15 mm nominal bore 15 mm nominal bore 72 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore 73 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore 74 Providing & fixing C.P. hand spray with lever control (health faucet) and flexible hose 1 m long connection with C.P. holder for hand spray complete in all respects. (Angle valve to be provide under item no. 18 and measure with that item.) 75 Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm 76 Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Coupler 110 mm 77 Bend 87.5 degree 110 mm Bend 78 Shoe (Plain) 110 mm Shoe 79 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 80 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. 81 Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : 110mm dia pipe. 82 Providing, fixing, jointing and testing,uPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. Internal Toilet (Soil, Waste & Rain Water Pipe) 110 mm dia. 83 Providing and fixing SWR PVC trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 110mm x 110mmX110mm 84 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Bend without door (87.5°) 110mm 85 Bend without door (45°) 110mm 86 Y Fitting without door 110mm 87 Single Tee without door 110 mm 88 Coupler 110mm 89 Vent Cowl 110mm 90 Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc.For Wash basin & Urinal 50mm dia. Pipe 91 40mm dia. Pipe (for wash basin & sunken toilet spout) 92 Elbow (90°) 50mm 93 Elbow (90°) 40mm 94 Elbow (45°) 50mm 95 Elbow (45°) 40mm 96 T fitting 50mm 97 T fitting 40mm 98 Coupler 50mm 99 Coupler40mm 100 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm dia nominal bore 101 20 mm dia nominal bore 102 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 25 mm dia nominal bore 103 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc Internal work - Exposed on wall / Terrace 20 mm dia nominal bore 104 25 mm dia nominal bore 105 32 mm dia nominal bore 106 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 20 mm dia nominal bore 107 25 mm dia nominal bore 108 32 mm dia nominal bore 109 Providing and fixing gun metal gate valve with wheel of approved quality. 20mm dia nominal bore 110 25mm dia nominal bore 111 32mm dia nominal bore 112 Providing , checking, storing, fixing in positionof approvedqualityScrewed ends Brass float valvewith brassballfloatandPTFE seat suitable forBody test pressure of 15Kg/sqcm of the following sizes:32mm dia nominal bore 113 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Fire Tank 114 Domestic Tank 115 INTERNAL W/S AND SANITATION (TB BLOCK-1) 116 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid 117 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 118 Providing and fixing uplasticised PVC connection pipe with brass unions : 30 cm length 15 mm nominal bore 119 45 cm length 15 mm nominal bore 120 Providing and fixing CP Brass 32mm/40mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 121 Providing and fixing 600 x 450mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete in all respect. 122 Providing and fixing toilet paper holder. C.P. brass 123 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 124 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 125 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (For bath) 15 mm nominal bore 126 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms 127 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter 128 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore 129 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore 130 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore 131 Providing & fixing C.P. hand spray with lever control (health faucet) and flexible hose 1 m long connection with C.P. holder for hand spray complete in all respects. (Angle valve to be provide under item no. 18 and measure with that item.) 132 Providing & fixingstorage type electric hot water heater 25 Litre made out of heavy gauge steel jacket finished with rust proof baked-on glossy white enamel paint, inside glass lined heavy gauge copper tank, 25 mm thick polyurethane foam insulation, thermostatically controlled immersion heater with pilot neon lamp, replaceable magnesium anode bar, suitable for 8.0 bar maximum working pressure, cold water inlet and hot water outlet pipe, suitable length of electrical cable and 15 amp 3 pin plug top, complete in all respect including testing etc.(Horizontal/Vertical) 133 Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm 134 Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Coupler 110 mm 135 Bend 87.5 degree 110 mm Bend 136 Shoe (Plain) 110 mm Shoe 137 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 138 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. 139 Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : 110mm dia pipe. 140 Providing, fixing, jointing and testing,uPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. Internal Toilet (Soil, Waste & Rain Water Pipe) 110 mm dia. 141 Providing and fixing SWR PVC trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 110mm x 110mmX110mm 142 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Bend without door (87.5°)110mm 143 Bend without door (45°) 110mm 144 Y Fitting without door 110mm 145 Single Tee without door 110 mm 146 Coupler 110mm 147 Vent Cowl 110mm 148 Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc.For Wash basin & Urinal 50mm dia. Pipe 149 40mm dia. Pipe (for wash basin & sunken toilet spout) 150 Elbow (90°) 50mm 151 40mm 152 Elbow (45°) 50mm 153 40mm 154 T fitting50mm 155 40mm 156 Coupler50mm 157 40mm 158 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm dia nominal bore 159 20 mm dia nominal bore 160 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 25 mm dia nominal bore 161 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc Internal work - Exposed on wall / Terrace 20 mm dia nominal bore 162 25 mm dia nominal bore 163 32 mm dia nominal bore 164 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 20 mm dia nominal bore 165 25 mm dia nominal bore 166 32 mm dia nominal bore 167 Providing and fixing gun metal gate valve with wheel of approved quality. 20mm dia nominal bore 168 25mm dia nominal bore 169 32mm dia nominal bore 170 Providing , checking, storing, fixing in positionof approvedqualityScrewed ends Brass float valvewith brassballfloatandPTFE seat suitable forBody test pressure of 15Kg/sqcm of the following sizes:32mm dia nominal bore 171 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Fire tank 172 Domestic Tank 173 INTERNAL W/S AND SANITATION (CHEST OPD) 174 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid 175 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 176 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe40 mm dia 177 Providing and fixing uplasticised PVC connection pipe with brass unions : 30 cm length 15 mm nominal bore 178 45 cm length 15 mm nominal bore 179 Providing and fixing CP Brass 32mm/40mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 180 Providing and fixing 600 x 450mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete in all respect. 181 Providing and fixing toilet paper holder. C.P. brass 182 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 183 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 184 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore 185 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore 186 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore 187 Providing & fixing C.P. hand spray with lever control (health faucet) and flexible hose 1 m long connection with C.P. holder for hand spray complete in all respects. (Angle valve to be provide under item no. 18 and measure with that item.) 188 Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion.110mm 189 Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.Coupler 110 mm 190 Bend 87.5 degree 110 mm Bend 191 Shoe (Plain) 110 mm Shoe 192 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 193 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. 194 Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : 110mm dia pipe. 195 Providing, fixing, jointing and testing,uPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. Internal Toilet (Soil, Waste & Rain Water Pipe) 110 mm dia. 196 Providing and fixing SWR PVC trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 110mm x 110mmX110mm 197 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Bend without door (87.5°) 110mm 198 Bend without door (45°)110mm 199 Y Fitting without door 110mm 200 Single Tee without door 110 mm 201 Coupler 110mm 202 Vent Cowl 110mm 203 Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. For Wash basin & Urinal 50mm dia. Pipe 204 40mm dia. Pipe (for wash basin & sunken toilet spout) 205 Elbow (90°) 50mm 206 40mm 207 Elbow (45°) 50mm 208 40mm 209 T fitting 50mm 210 40mm 211 Coupler50mm 212 40mm 213 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm dia nominal bore 214 20 mm dia nominal bore 215 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 25 mm dia nominal bore 216 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc Internal work - Exposed on wall / Terrace 20 mm dia nominal bore 217 25 mm dia nominal bore 218 32 mm dia nominal bore 219 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 20 mm dia nominal bore 220 25 mm dia nominal bore 221 32 mm dia nominal bore 222 Providing and fixing gun metal gate valve with wheel of approved quality. 20mm dia nominal bore 223 25mm dia nominal bore 224 32mm dia nominal bore 225 Providing , checking, storing, fixing in positionof approvedqualityScrewed ends Brass float valvewith brassballfloatandPTFE seat suitable forBody test pressure of 15Kg/sqcm of the following sizes:32mm dia nominal bore 226 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Domestic Tank 227 Providing and fixing fire extinguisher of carbon dioxide type consisting of brand new high pressure steel cylinder bearing IS: 7285 mark and having the approval of controller of explosives Nagpur, wheel type valve bearing IS:3224 mark internal discharge tube, 1 meter long high pressure discharge hose, non conducting horn, suspension bracket, fully charged bearing IS: making fixed to wall as directed. 4.5kg capacity cylinder. 228 ABC type extinguisher with cylinder fully charged with 6 Kg. capacity. 229 INTERNAL ELECTRIFICATION (TB BLOCK-2) 230 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 231 Wiring for group controlled (looped) light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed midium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 232 Wiring for light/ Power plug with 2X4 sq. mm FRLS PVC insuleted copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1Nos. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthingas required. 233 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire 234 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire 235 4 x 10 sq.mm. + 2 x 6 sq.mm. earth wire 236 4 x 16 sq.mm. + 2 x 6 sq.mm. earth wire 237 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 238 Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required.5/6 amps switch 239 15/16 amp switch 240 3 pin 5/6 amp socket outlet 241 6 pin 15/16 amp socket outlet 242 Telephone socket outlet 243 TV antenna socket outlet 244 DATA outlet 245 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. 246 Supplying and drawing telephone wire following pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. 2 Pair 247 10 Pair 248 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.2 run of cable 249 Installation, testing and commissioning of ceiling fan,including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 250 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 251 Installation of exhaust fan in the existing opening , including making good the damage, connection, testingcommissioning etc. as required. (a): Up to 450mm sweep 252 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 253 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25mm 254 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM(tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin,nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan 255 Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. 256 Supply ofrecess/Surface mounting round 8 watt, cut out Min 125mm, Height Min 40mm, LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set, suitable for 24Hr continuous Operation,complete in all respec. 257 Supply of LED Tube Light 20 watt Polycarbonate tube light complete including tube etc suitable for both surface & surface complete in all respects. 258 Supply of 7W Bulkhead light fixture with specification complete as per architectural design 259 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way Double door (4 + 18) 260 Supplying and fixing of following ways surface/ recess mounting,vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way Double door (4 + 12) 261 Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door TPN MCBDB 262 Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. 263 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 264 Supplying and fixing 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A 4P 265 40A 4P 266 Supplying and fixing 415 volts, 25ka,MCCB complete with connections, testing and commissioning etc. as required. 100A 4P 267 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 268 Suplly and burring of safe Earthing Electrode T-39 Cu Copper Coated, Length 2000mm, outer pipe 76.3mm X 3.2 inner pipe 42.4mm X 2.6mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50kgs activated soil (BFC) capable of reucing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame withhinged cover & mansonry housing.(From electrode terminal to switch board, cost of 25x3 copper strip will be extra) Make: As approved in U.P.P.W.D & C.P.R.I. all respects. 269 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 270 Supplying following 1.1kV grade, heavy duty XLPE insulated, FRLS type armoured /Unarmured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete as required. 25 sqmm3.5 core 271 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3½ X 25 sq. mm (28mm) 272 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm 273 Supply, Installation, Testing and Commissioning of 250mm size PVC exhaust fan suitable for 230V, 50 Hz AC including modifying and finishing for hole/opening for the size of fan, MS louver/ shutter complete with frame for Ex.fan including its connection with 3x1.5 sq mm FRLS copper conductor wire with PVC sleeve, loop earthing, making the good damage complete as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge. 274 S/f of 10 pair Telephone Tag Block for Floors and building with Krone connectors , with connection and punching of same 275 INTERNAL ELECTRIFICATION (TB BLOCK-1) 276 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 277 Wiring for group controlled (looped) light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed midium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 278 Wiring for light/ Power plug with 2X4 sq. mm FRLS PVC insuleted copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1Nos. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthingas required. 279 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire 280 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire 281 4 x 10 sq.mm. + 2 x 6 sq.mm. earth wire 282 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 283 Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required.5/6 amps switch 284 15/16 amp switch 285 3 pin 5/6 amp socket outlet 286 6 pin 15/16 amp socket outlet 287 Telephone socket outlet 288 TV antenna socket outlet 289 DATA outlet 290 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. 291 Supplying and drawing telephone wire following pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. 2 Pair 292 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.2 run of cable 293 Installation, testing and commissioning of ceiling fan,including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 294 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 295 Installation of exhaust fan in the existing opening , including making good the damage, connection, testingcommissioning etc. as required. (a): Up to 450mm sweep 296 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 297 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25mm 298 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM(tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin,nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.1200 mm sweep ceiling fan 299 Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. 300 Supply ofrecess/Surface mounting round 8 watt, cut out Min 125mm, Height Min 40mm, LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set, suitable for 24Hr continuous Operation,complete in all respec. 301 Supply of LED Tube Light 20 watt Polycarbonate tube light complete including tube etc suitable for both surface & surface complete in all respects. 302 Supply of 7W Bulkhead light fixture with specification complete as per architectural design 303 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way Double door (4 + 18) 304 Supplying and fixing of following ways surface/ recess mounting,vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way Double door (4 + 12) 305 Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. For 6 way, Double door TPN MCBDB 306 Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. 307 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 308 Supplying and fixing 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A 4P 309 Supplying and fixing 415 volts, 25ka,MCCB complete with connections, testing and commissioning etc. as required. 100A 4P 310 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 311 Suplly and burring of safe Earthing Electrode T-39 Cu Copper Coated, Length 2000mm, outer pipe 76.3mm X 3.2 inner pipe 42.4mm X 2.6mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50kgs activated soil (BFC) capable of reucing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame withhinged cover & mansonry housing.(From electrode terminal to switch board, cost of 25x3 copper strip will be extra) Make: As approved in U.P.P.W.D & C.P.R.I. all respects. 312 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 313 Supplying following 1.1kV grade, heavy duty XLPE insulated, FRLS type armoured /Unarmured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete as required. 25 sqmm3.5 core 314 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3½ X 25 sq. mm (28mm) 315 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm 316 Supply, Installation, Testing and Commissioning of 250mm size PVC exhaust fan suitable for 230V, 50 Hz AC including modifying and finishing for hole/opening for the size of fan, MS louver/ shutter complete with frame for Ex.fan including its connection with 3x1.5 sq mm FRLS copper conductor wire with PVC sleeve, loop earthing, making the good damage complete as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge. 317 S/f of 10 pair Telephone Tag Block for Floors and building with Krone connectors , with connection and punching of same 318 INTERNAL ELECTRIFICATION (CHEST OPD) 319 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 320 Wiring for group controlled (looped) light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed midium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 321 Wiring for light/ Power plug with 2X4 sq. mm FRLS PVC insuleted copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1Nos. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthingas required. 322 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire 323 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire 324 4 x 10 sq.mm. + 2 x 6 sq.mm. earth wire 325 4 x 16 sq.mm. + 2 x 6 sq.mm. earth wire 326 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 327 Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required.5/6 amps switch 328 15/16 amp switch 329 3 pin 5/6 amp socket outlet 330 6 pin 15/16 amp socket outlet 331 Telephone socket outlet 332 TV antenna socket outlet 333 DATA outlet 334 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. 335 Supplying and drawing telephone wire following pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. 2 Pair 336 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.2 run of cable 337 Installation, testing and commissioning of ceiling fan,including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 338 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 339 Installation of exhaust fan in the existing opening , including making good the damage, connection, testingcommissioning etc. as required. (a): Up to 450mm sweep 340 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 341 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25mm 342 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM(tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin,nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan 343 Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. 344 Supply ofrecess/Surface mounting round 8 watt, cut out Min 125mm, Height Min 40mm, LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set, suitable for 24Hr continuous Operation,complete in all respec. 345 Supply of LED Tube Light 20 watt Polycarbonate tube light complete including tube etc suitable for both surface & surface complete in all respects. 346 Supply of 7W Bulkhead light fixture with specification complete as per architectural design 347 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way Double door (4 + 18) 348 Supplying and fixing of following ways surface/ recess mounting,vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way Double door (4 + 12) 349 Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. For 6 way, Double door TP 350 Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. 351 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 352 Supplying and fixing 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A 4P 353 63A 4P 354 Supplying and fixing 415 volts, 25ka,MCCB complete with connections, testing and commissioning etc. as required. 160A 4P 355 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 356 Suplly and burring of safe Earthing Electrode T-39 Cu Copper Coated, Length 2000mm, outer pipe 76.3mm X 3.2 inner pipe 42.4mm X 2.6mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50kgs activated soil (BFC) capable of reucing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame withhinged cover & mansonry housing.(From electrode terminal to switch board, cost of 25x3 copper strip will be extra) Make: As approved in U.P.P.W.D & C.P.R.I. all respects. 357 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 358 Supplying following 1.1kV grade, heavy duty XLPE insulated, FRLS type armoured /Unarmured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete as required. 3½ X 35 sq. mm 359 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3½ X 25 sq. mm (28mm) 360 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm 361 Supply, Installation, Testing and Commissioning of 250mm size PVC exhaust fan suitable for 230V, 50 Hz AC including modifying and finishing for hole/opening for the size of fan, MS louver/ shutter complete with frame for Ex.fan including its connection with 3x1.5 sq mm FRLS copper conductor wire with PVC sleeve, loop earthing, making the good damage complete as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge. 362 RAIN WATER HARVESTING 363 Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m. In all kind of soil upto 1.5m depth 364 In all kind of soil upto 1.5m to 3.0m. depth 365 In all kind of soil upto 3.0m to 4.5m. depth 366 In all kind of soil upto 4.5 m to 6.0m. depth 367 Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. 368 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) 369 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 370 Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform. 371 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more. 372 12mm cement plaster on rough side of single or half brick wall mix1:3 (1 cement : 3 Coarse sand) 373 Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar 374 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter 375 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. Drilling of 300mm dia bore hole manually. 376 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia 377 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 378 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 379 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge. 380 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 381 Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m. In all kind of soil upto 1.5m depth 382 In all kind of soil upto 1.5m to 3.0m. depth 383 Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand:4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. 384 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) 385 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 386 Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform. 387 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more. 388 12mm cement plaster on rough side of single or half brick wall mix1:3 (1 cement : 3 Coarse sand) 389 Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar 390 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter 391 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm. 392 Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) Depth not exceeding 1.5 meter 393 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150 mm.dia. RCCPipes 394 250 mm.dia. RCCPipes 395 300 mm.dia. RCCPipes 396 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete.150 mm.dia. RCCPipes 397 250 mm.dia. RCCPipes 398 300 mm.dia. RCCPipes 399 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With common burnt clay FPS (non modular) bricks of class designation 7.5 400 Providing orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 401 FIRE FIGHTING WORK (TB BLOCK-2) 402 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for nclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head. 403 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required 1.2 Meter high and 250 mm dia. 404 Supply, Installation, testing and commissioning of pressure switches for Hydrant / Diesel Engine Driven Pump / Jockey Pumps, diaphragm type, adjustable range from 0-9 bar and a regulation range of 0.1 - 1.5 bar direct mounted SNAP acting type made from die cast aluminium with epoxy powder coated finish and SS316 diaphragm and other wetted parts, including necessary wiring upto control panel & other materials as required as per specifications. 405 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm dia 406 25 mm dia 407 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required 100 mm dia 408 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required 100 mm dia 409 Supply, Installation, Testing and Commissioning of 100 mm dia Bourden type, Stainless Steel dial type Pressure Gauge including brass isolation valve and siphon pipe having calibration of 0 - 16 Kg / cm2 . 410 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange 100 mm dia 411 Supplying and Fixing of Fire Mans axe with heavy insulated rubber as per standard conforming to IS 926. 412 Providing & fixing double flanged Metallic expansion with M.S. fixed flanges (PN-1.6) joint (suitable for system test pressure) of standard length as per manufacturers specs including rubber gaskets, flanges, nuts, bolts and washers complete as required as per specifications. 100 mm dia 413 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following asrequired. 20 mm nominal internal dia water hose thermoplastic(Textile reinforced) type -2 as per IS: 1258520 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metalvalve & M.S. Pipe and socket 40M 414 Supplying, installation, testing and commissioning ofweather proof M.S door and glass fire door size 2100 mmx 900mm fabricated from 1.6mm thick M.S. sheets and M.S angle 40mmx40mmx6mm complete with glass, locking arrangements to accommodate the following: - 415 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way-100 mm dia M.S. Pipe 416 Providing and fixing fire extinguisher of carbon dioxide type consisting of brand new high pressure steel cylinder bearing IS: 7285 mark and having the approval of controller of explosives Nagpur, wheel type valve bearing IS:3224 mark internal discharge tube, 1 meter long high pressure discharge hose, non conducting horn, suspension bracket, fully charged bearing IS: making fixed to wall as directed. 4.5kg capacity cylinder. 417 ABC type extinguisher with cylinder fully charged with 6 Kg. capacity. 418 FIRE FIGHTING WORK (TB BLOCK-1) 419 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for nclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head. 420 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required 1.2 Meter high and 250 mm dia. 421 Supply, Installation, testing and commissioning of pressure switches for Hydrant / Diesel Engine Driven Pump / Jockey Pumps, diaphragm type, adjustable range from 0-9 bar and a regulation range of 0.1 - 1.5 bar direct mounted SNAP acting type made from die cast aluminium with epoxy powder coated finish and SS316 diaphragm and other wetted parts, including necessary wiring upto control panel & other materials as required as per specifications. 422 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100mm dia 423 25 mm dia 424 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required 100 mm dia 425 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required 100 mm dia 426 Supply, Installation, Testing and Commissioning of 100 mm dia Bourden type, Stainless Steel dial type Pressure Gauge including brass isolation valve and siphon pipe having calibration of 0 - 16 Kg / cm2 . 427 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange 100 mm dia 428 Supplying and Fixing of Fire Mans axe with heavy insulated rubber as per standard conforming to IS 926. 429 Providing & fixing double flanged Metallic expansion with M.S. fixed flanges (PN-1.6) joint (suitable for system test pressure) of standard length as per manufacturers specs including rubber gaskets, flanges, nuts, bolts and washers complete as required as per specifications.100mm dia 430 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following asrequired. 20 mm nominal internal dia water hose thermoplastic(Textile reinforced) type -2 as per IS: 1258520 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metalvalve & M.S. Pipe and socket 40M 431 Supplying, installation, testing and commissioning ofweather proof M.S door and glass fire door size 2100 mmx 900mm fabricated from 1.6mm thick M.S. sheets and M.S angle 40mmx40mmx6mm complete with glass, locking arrangements to accommodate the following: - 432 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way-100 mm dia M.S. Pipe 433 Providing and fixing fire extinguisher of carbon dioxide type consisting of brand new high pressure steel cylinder bearing IS: 7285 mark and having the approval of controller of explosives Nagpur, wheel type valve bearing IS:3224 mark internal discharge tube, 1 meter long high pressure discharge hose, non conducting horn, suspension bracket, fully charged bearing IS: making fixed to wall as directed.4.5kg capacity cylinder. 434 ABC type extinguisher with cylinder fully charged with 6 Kg. capacity. 435 EXTERNAL ELECTRICAL WORK 436 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing. 437 Supply and burring of Safe Earthing Electrode T-39 AAlloy Coated, Length 3000mm, outer pipe 76.3mm x 3.2 inner pipe 42.4mm x 2.6mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonry housing.d. 438 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 439 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 440 Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130 mm and base plate 12 mm thik) having 3mm thikness with Single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P complete in all respect. 441 Supply and fixing of LED street light fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 watt. Confirming to IP 66 and above protection complete in all respect. 442 Supply and fixing of 20 Amp DP MCB (10KA) (C curve) for poles 443 Supply and fixing of Bakelite sheet 3 mm thick of suitable size & connector 444 Supplying following 1.1kV grade, heavy duty XLPE insulated, FRLS type armoured /Unarmured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete as required. 3.5C x 120 sqmm aluminium conductor, A2XWY. 445 2C x 10 sqmm aluminium conductor, A2XWY. 446 2C x 6 sqmm aluminium conductor, A2XWY. 447 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle) 448 Above 95 sq. mm and upto 185 sq. mm(clamped with 1mm thick saddle) 449 Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3½ X 120 sq. mm (45 mm) 450 2 X 10 sq. mm (19mm) 451 2 X 6 sq. mm (19mm) 452 Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.90 mm dia (OD-90 mm & ID-76 mm nominal) 453 63 mm dia (OD-63 mm & ID-51 mm nominal) 454 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.100 mm dia 455 150 mm dia 456 Making of following size of Cable Chamber made of 230 mm thick brick work in cement mortar (1 cement : 6 sand) with PCC 100 mm thick PCC base plastering of inner and outer surface with cement mortar including providing of Heavy Duty C.I Cover complete with digging, refilling and removal of surplus soil complete as required. 900 mm x 800 mmx 1000 mm deep 457 600 mm x 600 mmx 800 mm deep 458 SITC OF MAIN PANEL FEEDER PILLARDesign, Supply, installation, testing and commissioning of indoor/outdoor floor mounted/ wall mounted, IP43/IP65, IEC 61439/IS 8623, factory built, modular, sectionalised, compartmentalized, extendable type HT/LT cubicle panel of suitable size suitable for operation on 33/11/0.433/0.415kV, 50 Hz AC 3 phasesupply system fabricated from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates with stiffeners wherever required, having vibration free structure chemically treated with seven tank process or better before painting for surface treatment and powder coated in approved shade, with suitable electrolytic grade high conductivity bus bars extensible, DMC/ SMC (whichever is superior) bus bar supports, with short circuit withstand capacity as mentioned ,bottom base channel of section not less than 100mmX 50mmX 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common earth bar of required size at the rear with 2 Nos. earth stud, connections and interconnection with solid conductor wires / copper strips, neutral links, control wiring with 1.5 sqmm. & 2.5sqmm. PVC insulated FRLS copper conductor S/C cable for voltage & current respectively, including providing and fixing following switch gears as per SLD ,technical specifications etc.complete in all respect so as to fulfill all as required. Panel described as above 459 EXTERNAL WATER SUPPLY & DRAINAGE WORK 460 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm. 461 Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) Depth not exceeding 1.5 meter 462 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150 mm.dia. RCCPipes 463 250 mm.dia. RCCPipes 464 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete.150 mm.dia. RCCPipes 465 250 mm.dia. RCCPipes 466 Providing and fixing square-mouth S.W. gully trap SP-1 complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm size P type With common burnt clay FPS (non modular) bricks of class designation 75 467 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: 100 mm diameter 468 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With common burnt clay FPS (non modular) bricks of class designation 7.5 469 Extra for depth for manholes:Size 90x80cmWith common burnt clay FPS (non modular) bricks of class designation 7.5 470 Providing orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 471 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :-Pipes, cables etc, not exceeding 80 mm dia. 472 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 25 mm dia nominal bore 473 32 mm dia nominal bore 474 40 mm dia nominal bore 475 50 mm dia nominal bore 476 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :- 25 mm dia nominal bore 477 32 mm dia nominal bore 478 40 mm dia nominal bore 479 50 mm dia nominal bore 480 Providing and filling sand of grading zone V or coarser grade alround the G.I. pipes in external work. 25 mm dia nominal bore 481 32 mm dia nominal bore 482 40 mm dia nominal bore 483 50 mm dia nominal bore 484 Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 25 mm dia nominal bore 485 32 mm dia nominal bore 486 40 mm dia nominal bore 487 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required:- 50 mm dia 488 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore 489 Constructing masonry Chamber 60 x 60 x 75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 fine sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and180 mm deep (inside) with chain lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. With F.P.S. bricks 490 Constructing brick masonry surface drain with bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 20 mm nominal size) and 25 mm thick cement concrete 1:2:4 (1 cement 2 coarse sand 4 graded stone aggregate12.5mm nominal size) for filling haunches including 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) with a floating coat ofneat cement inside thedrain, its top and exposed side and 12mm thick external plaster with cement mortar 1:6 (1 cement : 6 coarse sand) including connection to existing drain and disposal of surplus earth. 30 cm drain 45 cm average depth 491 45 cm drain 60 cm average depth 492 SEPTIC TANK & SOAK PIT (02 No.) 493 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge. In all kind of soil upto 1.5m depth 494 In all kind of soil upto 1.5m to 3.0m. depth 495 In all kind of soil upto 3.0m to 4.5m. depth 496 Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 40mm nominal size) 497 Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand) 498 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 499 Suspended floors, roofs, landings, balconies and access platform. 500 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 501 12mm cement plaster on rough side of mix 1:3 (1 cement : 3 coarse sand) 502 Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 503 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 504 Providing & fixing 75mm dia vent pipes. 505 Providing & fixing of 75mm dia cast iron terminal guard. 506 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter 507 M.D. -2.5- Circular shape 450mm internal diameter 508 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks 509 GST Extra as per applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
48.
Agriculture #9433700 Technical Bid
Compititive Ebidding For Supply Of Hardware Items For Season 2023-24 , Hardware Items , Rubber Oil Seal Metallic & Non Metallic Mykoda/Oskomake , All Type Of Gun Metal Valves Serewed & Flanged From 3/8” To 2” Make Zoloto/Leader , Ss Ball Valves Isi Mark , Size- 3/8” , Size- ½” , Size- ¾” , Size- 1” , Seamless Pipe Size ½” To 8” With Ibr Test Certificate Msl Make , Teflonrod ( White) , 1” X 12” , 1 ½X 12” , 2” X 12” , Metalon Sheet 1Mtr X 1 Mtr X 1 ½” Thik. , Nylon Wire Brush 20Mm , Metlenrod , 65Mm X 300Mm (Solid) , 75Mm X 300Mm (Solid) , 90Mm X 300Mm (Solid) , 100Mm Od X 70Mm Id X 300Mm Length (Hollow) , 110Mm Od X 80Mm Id X 300Mm Length (Hollow) , Flat Belt Dunlop / Goodyear Make , 2” X 4 Ply , 4” X 4 Ply , 5” X 8 Ply , 6” X 8 Ply , Rubber House Pipe Double Ply , Size ½” , Size ¾” , Size 1” , Wire Braded Flexible Pipe With Both End Connectors , Size ¼” X ¼ Mtr , Size ¼” X ½ Mtr , Size ¼” X 1Mtr , Size ¼” X 1 ½ Mtr , Size ¼” X 1 ½ Feet , Size 3/8” X ¼Mtr , Size 3/8” X ½ Mtr , Size 3/8” X 1 Mtr , Size 3/8” X1½ Mtr , Size 3/8” X 1 ½ Feet , Size ½” X ½ Mtr , Size ½” X 1 Mtr , Size ½” X1½ Feet , Hydraulic Rubber Hose Pipe With Both End Connectors , Size¼” X 2 Feet , Size3/8” X ½ Mtr , Size3/8” X 1Mtr , Size 3/8” X 1 ½ Feet , Size 3/8” X 4 Feet , Size½” X 2 Feet , Size ½” X 2 ½ Feet , Size ¾” X 3 ½ Feet , Oil Fiter Hydroline Make , Size Sc-050 , Size Sc3 -015 , Size Sc3- 010 , Steel Wire Hand Brush 6” X 2” , Brake Liner 6” Wide X 10Mm Thick , Thermometer 0-110°C , Painting Brush , Size 2” , Size 3” , Size 4” , Size 5” , Size 6” , Redoxide Primer British Paint/Asian Make ( 20 Litr Drum) , G.P Thiner 20 Litr Drum , Brass Strip 25Mm X 25Mm X 1.5 Mtr Long , Brass Rod ½” To 2” , Dunlop Make Rubber Adhesive 786 1 Kg Packing , Araldite Ciba-Giegy Make , 36Gm Set , 72Gm Set , 180 Gm Set , 100 Gm Set , Dendrite Tube 25Ml , M-Seal Mahindra / Pidlite/Astral , M-Seal Phataphat 30Gm Set , Boiler Gauge Glass Bishop Make , Size ¾” X 16” ½” , Size ¾” X 22 ½”Boiler Gauge B-9Glass , Klinger Make Gasket For B9 Glass , Rubber Cone ¾” For Gauge Glass National/Leades Make , Sleeve 3/4” For Gauge Glass Leader Make , Mica Sheet For B- Gauge Glass , Manila Rope ¾” & 1” , Pvc Rope ¾” & 1” Garware Make /Trishul Make , White Albestos Rope1/8 , White Albestos Rope3/8 , White Albestos Rope1/2 , White Albestos Rope3/4 , Solenoid Valve With Coil Rotex Make , Model No – 3012 Two Way , Model No- 3013 One Way , General Items , Aluminum Rivet ¼” X 2” /1/4” X 2 ½ , Hydex Ci Coupling M-48 Complete Set Dyna Make , Teflon Tap ¾” X 10 Mtr , Holdtite Compound 500 Ml Pidlite Make , Restolene Pidlite Make 50Ml , Gasket Shellac Compound 25Ml , Blue Tube 25Ml Atlas Make /Camel Make , Piano Wire 250 Gm Roll , Brasso 100 Ml , Graphite Powder , Stag Jointing Paste, Type B-Red, 500Gram , Emery Tape(Rough 2) , Emery Tape(Fine 2) , Emery Cloth(Rough) , Emery Cloth(Fine) , Hexsaw Blade 1/2 X12 Miranda Make , Shellac Compound(250/25Gm) , Thread Locker/Loctite (No. 112) 250Ml Anabond Make , Grinding Wheels Ag4 Dewalt/Bosch Make , Grinding Wheelsag7 Dewalt/Bosch Make , Buffing Wheels4 Dewalt/Bosch Make , Buffing Wheels7 Dewalt/Bosch Make , Ci Pulley Wk 1500M/C Od-310Mm, Bore-97Mm, Spc/C Groove-05 Grooves On Conversion , Ci Flange Coupling 8 With Bush Complete Set , Copper Pipe Od-6Mm , Needle Valve 1/2 , Brass Ferulls Id-6Mm , Oil Packet Ss 12 , Cotton Waste , Markeen Cloth , Angle Grinder 4 , Angle Grinder 7 , Cast Steel Gear Couplings , Gc-102 , Gc-103 , Gc-104 , Gc-105 , Gc-106 , Gc-107 , Gc-108 , Gc-109 , Gc-110 , Bearing Sleeves Jmc Make , Copper Flatsheet , Graphite Crucible Double Kabootar Make , 80No , 100 No , Wire Braded Rubber Hose Pipe ¾” For Steam , Diamond Make Simplex Chain 2 ½ Pitch , 1”Pitch , 2” Pitch , 2 ½” Pitch , 3” Pitch , Full Link Coupler 2 ½” Pitch , Half Link Coupler 2 ½” Pitch , Love Joy Ci Coupling Set , L-70 , L-75 , L-90 , L-100 , L-110 , C.I Tyre Coupling Set Complete , Px-50 , Px-60 , Px-70 , Px-80 , Px-90 , Px-100 , Px-110 , Px-120 , Px-140 , Ph-140 , Ph-176 , Ph-190 , Ph-218 , Spare Coupling Tyres , Px-50 , Px-60 , Px-70 , Px-80 , Px-90 , Px-100 , Px-110 , Px-120 , Px-140 , Ph-140 , Ph-176 , Ph-190 , Ph-218 , “Usha” Martin Make Steel Wire Rope ¾”/6/36” Hemp Core With Test Certificate (305Mtr) , High Tensile Bolt/Nut “Unbrako”Make , “Indef” Make Chain Blocks With Test Certificate With10 Mtr Lift , Capacity 1 Ton , Capacity 2 Ton , Capacity 3 Ton , Capacity 5 Ton , Capacity 10 Ton , Wire Braded Rubber Hose Pipe ¾” For Steam , Spares For Sugar Weighing & Bagging Machine , Janatics Make Solenoid Valve With Coil 3/2 Way , Load Cell, Capacity 110Kg, , Pu Tube Size Id-6Mm, Od-8Mm , Pu Tube Sizeid-8Mm, Od-10Mm , Air Filter Regulator Size 1/4 Bsf , Straight Connector 1/4 , Tee Connector- Push Type 1/4 X 8Mm , Temp., Pressure, Vaccum Guages , Temp Gauge Range 0-150 Degree C Dial Size 6”. Stem Dia-8 Mm (Probe Type) Connection -1/2” Bsp (M) Make- Hguru/ Bomber Mounting –Direct Bottom , Temp Gauge Range 0-100 Degree C Dial Size 6”. Wired Type- 8Mtr Connection -1/2” Bsp (M) Make- Hguru/ Bomber Mounting –Direct Bottom , Temp Gauge Range 0-200 Degree C Dial Size 6”. Wired Type- 8Mtr Connection -1/2” Bsp (M) Make- Hguru/ Bomber Mounting –Direct Bottom , Vacuum Gauge Range 0- 760 Mmhg Dial Size 6”. Connection: ½” Bsp (M). Make- Hguru/ Bomber Mounting –Direct Bottom , Temp Gauge Range 0-600 Degree C Dial Size 6”. Wired Type- 8Mtr Connection -1/2” Bsp (M) Make- Hguru/ Bomber Mounting –Direct Bottom , Temp Gauge Range 0-200 Degree C Dial Size 6”. Stem Dia-8 Mm (Probe Type) Connection -1/2” Bsp (M) Make- Hguru/ Bomber Mounting –Direct Bottom , Temp Gauge Range 0-600 Degree C Dial Size 6”. Stem Dia-8 Mm (Probe Type) Connection -1/2” Bsp (M) Make- Hguru Mounting –Direct Bottom , Pressure Gauge Range 0-4Kg/Cm2 Dial Size 6”. Connection -1/2” Bsp (M) Make- Hguru/ Bomber Mounting –Back Nut , Pressure Gauge Range 0-60Kg/Cm2 Dial Size 6”. Connection -1/2” Bsp (M) Make- Hguru/ Bomber Mounting –Back Nut , Circular Exhaust/Steam Pressure Graph Paper
Contract Date: Ref. Documents Contract Value : Ref. Document
Cooperative No of Bidders 5
Uttar Pradesh View Result →
49.
Agriculture #9433011 Technical Bid
Supply Of Air Compressor Spares And Servicing , Spares For Ingersollrand Make Air Compressor Model 8 X 5 Esv-1 Lub , Valve Discharge Complete , Channel & Spring Set Discharge , Channel & Spring Set Suction , Cap Screw , Lock Washer , Valve Inlet Complete , Plunger Unloader , ‘O’Ring , Springplunger , Piston Ringset ( C.I. ) , Cap Screw Gauge Hex Head , Gasket Set Complete , Seal For Oil Pump ( Lub. ) , Oil Lubricator Complete , Auxillary Valve , Stop Plate Discharge , Stop Plate Suction , Ht Bolt D-7, D-8, D-9, D-10, D-14, D-11, D-13 , Flat ‘O’ Ring U / L , Glass Lubricator , Flat ‘H’ Screw , Cylinder Block 8 , Oil Seal Crank Shaft , O Ring For Oil Chamber , Valve Seat Plate ( Discharge ) , Air Scraper Ring , Oil Scraper Ring , Star Washer Piston Ring , Air Filter Element , Oil Pressure Gauge 63 Mm , Plunger Cover U / L , Oil Pump Housing , Oil Stainer , Rubber Star Coupling For Lubricator , Crank Shaft Bearing Right Side , Crank Shaft Bearing Left Side , Crank Shaft Centre Bush , Crank Shaft Oil Seal , Guide Holder , Air Pressure Ring , Oil Pressure Ring , Wheel Mounting Sleeve , U / L Repair Kit , Discharge Valve Mounting Bolt With Washer , Suction Valve Mounting Bolt With Washer , Wheel Mounting Sleeve , U / L Repair Kit , Discharge Valve Mounting Bolt With Washer , Suction Valve Mounting Bolt With Washer , Oil Filter , Port Plate Up Site , Port Plate Down Side , Hex Bolt Port Plate , Fau Kit , Spares For Ingersollrand Make Air Compressor Model 9.5 X 7 Esv-1 Lubricated , Channel & Spring Setdischarge , Channel & Spring Set Suction , Discharge Valve Complete , Unloader Fre Air Complete , Cap Screw , Lock Washer , Plunger , Spring , ‘O’ Ring , Plate Seat , Platestop , Air Filter , Dowel Pin , Machine Screw , Gasket Set , Oil Filter , Ht Bolt D-7, D-8, D-9, D-10, D-14 , Lubricator , Oil Scrapper Set , Auxilarry Valve , Piston Ring C.I. , Suction Valve , Rubber Star Coupling , Valve Seat Plate Discharge , Valve Seat Plate Suction , Star Washer , Air Scraper Ring , Valve Plate Screw , Oil Stainer , Oil Pump Housing , Plunger U / L Complete With Cover , Unload Flat O Ring , Crank Shaft Oil Seal , Air Pressure Ring , Oil Pressure Ring , Guide Holder ( D ) , Guide Holder ( S ) , U / L Rubber O Ring , U / L Teflon O Ring , Valve Seat Plate ( Suction ) , Air Filter , Oil Filter , Pump Shaft Oil Seal , Oil Pressure Gauge ( 6 Kg / Cm ) , Lubricator Coupling , Gasket Set , U / L Repair Kit , Bottom Colling Rubber O Ring , Suction Valve Cover , Guide Holder Diaphragm , Spares For Ingersoll Rand Make Air Compressor Model11 X 7 Esv-1 Lubricated , Discharge Valve Complete , Seat Valve , Plate Seat , Guide , Dowel , Plate Stop , Channel & Spring Set ( Discharge ) , Machine Screw , Machine Screw , Lock Washer , Inlet Valve Complete , Seat Valve , Plate Seat , Guide , Dowel , Channel & Spring Set ( Suction ) , Machine Screw , Plunger , Spring , Plunger U / L , Screw For Suction Valve , Spring Lift , Pistion Ring Set , Screw F.H.D. Cvr , Screw F.H.D , Lock Washer , Screwx12a , Reducer , Wing Nut , Aux. Valve Complete , Washer Star Head , Discharge Valve Carb.. , Plate Stop , Air Filter , Guide Holder ( Discharge ) , Gasket Set , Screw Guide Holder , Ring Piston Set , S.S.Screw For Discharge Valve , Screw For Suction Valve , Valve Seat Plate ( Discharge ) , Air Scraper Ring , Oil Scraper Ring , Chamber Filter , Cover Gasket O Ring , Suction Valve Cover Rod , Piston Ring , Guide Holder , Screw For Valve Plate , Screw For Cover , Valve O Ring , Valve Copper Gaskit O Ring , Valve Cover Copper Gaskit O Ring , Guide Holder ( Suction ) , Valve Seat Plate ( Suction ) , Gasket Set Metallic , Valve Seat Plate ( Suction ) , Spares For Ingersollrand Make Air Compressor Model 7 X 5 `V-1 Lubricated , Inlet Valve Complete , Channel & Spring Set ( Discharge ) , Cap Screw Hex-Hd , Spring , ‘O’ Ring , Discharge Valve Complete , Plate Stop ( Discharge ) , Guide Valve , Dowel , Lock Washer , Lock Washer Star , Nut X Headjam , Plate Seat ( Discharge ) , Guide Holder ( Discharge ) , Gasket Set , Flat ‘O’ Ring U / L , Rubber ‘O’ Ring U / L , Oil Ring Scrapper , Coupling ( Set Of 2 Nos ) , Lubricator , Air Scraper Ring , U / L Valve ( 7 Kg / Cm² Pressure ) , Head H.T.Bolt End , Head H.T.Bolt Outer , H.T. Bolt D-11, D-13 , Piston Ring ( C.I. ) , Auxillary Valve , Pump Oil Seal , Air Pressure Ring , U / L Spring , Channel & Spring Set ( Suction ) , Plate Stop ( Suction ) , Guide Holder ( Suction ) , Plate Seat , Gland Copper Gaskit , U / L Teflon O Ring , Main Bearing , Cr Bearing , U / L Repair Kit , Oil Seal For Crank Shaft , Air Filter Complete , Fau Kit , Spares For Ingersollrand Make Air Compressor Model 8 X 7 Esv-1Non-Lubricated , Channel & Spring Set Inlet , Channel & Spring Set Disch.. , Ring & Spring Packing Set , Ring Oil Scrapper Set , Ring Oil Scrapper Set , Ring Piston Set , Gasket Set Complete , Cap Screw Cage Pau , Cap Screw Plate Seat , Cap Screw Seat Valve , Cap Screw- Stp-Val Dis.. , Cap Screw-Stp-Plt In Vlv.. , Lock Washer Star , Oil Filter , Valve Discharge Complete , Valve Inlet Comlete , Unloader Fre Air Complete , Cage Unloader , Plunger Unloader , Spring Unloader , ‘O’ Ring , Ring Piston , Cap Screw Valve Seat , Teflon Guide , Guide Holder Teflon , Wear Ring , Piston Ring , Ring And Spring Set , High Tension Bolt D-7 , Do But D-7 , High Tension Bolt D-9 , Top Cover Bolt , Wear Ring , Rubber ‘O’ Ring U / L , Flat ‘O’ Ring U / L , Flat ‘H’ Screw , Bottom ‘H’ Screw , Oil Scrapper Set , Auxillary Valve , Gasket Set , Piston Ringteflon , Wear Ring Teflon , Valve Discharge , Valve Seat Plate , Valve Stop Plate Suction , Air Scraper Ring , Oil Scraper Ring , Oil Seal For Crank Shaft , Housing Rubber , Channel Strip Teflon , Air Pressure Teflon Ring ( Discharge / Suction ) , Lubricator Oil Pump , U / L Repair Kit , Air Filter , Spares For Model 244 Ingersoll Rand Make , Connecting Rod Lp & Hp , Gasket Set , Piston Lp & Hp , Crank Pin Bush , Valve Plate Lp & Hp , Finger Strip Lp & Hp , Piston Ring L.P. / H.P. , Valve Pattin L.P. / H.P. , Valve Plate L.P. / H.P. , Air Filter Complete , Safty Valve Size 1 / 2 , Non Return Valve Size 1 , Pressure Switch , Model Kirloskar Eh 100 , Discharge Valve Complete , Suction Valve Complete , Gasket Set , Piston Ring Set , Auxilary Valve , Lock For ( Suction ) Fork , Main Bearing Set , C.R. Bearing Set , Rubber ‘O’ Ring U / L , Tie Bolt Complete With Washer Nut And Socket , Lanten , Valve U / L Plunger , Valve O Ring , Oil Pressure Guage 2 Dial , Valve Unloader , Lock Pin For Connecting Rod , Oil Pressure Limit Switch , Gaskit For Cylinder , Gaskit For Head , Suction Filter , Lock For Suction Valve , Copper Ring For Valve ( L.P. ) , Copper Ring For Valve ( H.P. ) , Rubber Ring ( L.P. ) , Gaskit For Valve ( H.P. ) , Piston Ring C.I. ( Pressure Ring ) , Nrv Valve With Body , Cylinder Standard , Pressure Regulator 7 Kg , Oil Filter , Valve Repairing Kit ( Suction ) , Valve Repairing Kit ( Discharge ) , Diaphragm Unloader Assembly , Servicing Charges Of Above Air Compressors
Contract Date: Ref. Documents Contract Value : Ref. Document
Cooperative No of Bidders 3
Uttar Pradesh View Result →
50.
Power #9432779 Technical Bid
Supply Of Spares Supply Of Different Types Of Press / Temp Elements For 2X500 Mw, Dtps, Anpara ( Sonebhadra ) . , Temp Gauge 0-100 Deg C Type: Inert Gas Temp Gauge ( Gas Tg ) Dial Size:150Mm Range : As Per Given Measurement Case: Die Cast Aluminum -Ip65 Bourdon: Ss 316 Movement :Ss 304 Stem, Bulb, Connection : Ss 316 Bulb Dia:12 Mm Entry: Mounting Bottom - Surface Tg Connection:1 / 4 Inch Npt ( M ) Capillary:10M-Ss 316 Capillary With Ss 304 Armour Compensation: Case , Temperature Gauge ( 0-100° C ) Type: Inert Gas Temp Gauge ( Gas Tg ) Dial Size:150Mm Range : As Per Given Measurement Case: Die Cast Aluminum -Ip65 Bourdon: Ss 316 Movement :Ss 304 Stem, Bulb, Connection : Ss 316 Bulb Dia:12 Mm Entry: Mounting Bottom - Surface Tg Connection:1 / 4 Inch Npt ( M ) Capillary:10M-Ss 316 Capillary With Ss 304 Armour Compensation: Case Compensation Zero Adjustment: Micrometer Screw On Pointer Adjustable From Front Window: Shatterer Proof Glass Bore Dia: ( Bulb Dia+1 ) Mm Il ( Mm ) , El ( Mm ) : Il-175Mm, El 50Mm Instrument Connection On Thermowell: ¼ Inch Npt ( F ) Tip Dia:25Mm , Temperature Gauge ( 0-100° C ) Type: Inert Gas Temp Gauge ( Gas Tg ) Dial Size:150Mm Range : As Per Given Measurement Case: Die Cast Aluminum -Ip65 Bourdon: Ss 316 Movement :Ss 304 Stem, Bulb, Connection : Ss 316 Bulb Dia:12 Mm Entry: Mounting Bottom - Surface Tg Connection:1 / 4 Inch Npt ( M ) Capillary:10M-Ss 316 Capillary With Ss 304 Armour Compensation: Case Compensation Zero Adjustment: Micrometer Screw On Pointer Adjustable From Front Window: Shatterer Proof Glass Bore Dia: ( Bulb Dia+1 ) Mm L ( Mm ) , El ( Mm ) :Il- 80Mm, El 50Mm Instrument Connection On Thermowell: ¼ Inch Npt ( F ) Tip Dia:25Mm , Temperature Gauge ( 0-100° C ) Type: Inert Gas Temp Gauge ( Gas Tg ) Dial Size:150Mm Range : As Per Given Measurement Case: Die Cast Aluminum -Ip65 Bourdon: Ss 316 Movement :Ss 304 Stem, Bulb, Connection : Ss 316 Bulb Dia:12 Mm Entry: Mounting Bottom - Surface Tg Connection:1 / 4 Inch Npt ( M ) Capillary:10M-Ss 316 Capillary With Ss 304 Armour Compensation: Case Compensation Zero Adjustment: Micrometer Screw On Pointer Adjustable From Front Window: Shatterer Proof Glass Bore Dia: ( Bulb Dia+1 ) Mm L ( Mm ) , El ( Mm ) :Il- 200Mm, El 50Mm Instrument Connection On Thermowell: ¼ Inch Npt ( F ) Tip Dia:25Mm , Temperature Gauge ( 0-100° C ) Type: Inert Gas Temp Gauge ( Gas Tg ) Dial Size:150Mm Range : As Per Given Measurement Case: Die Cast Aluminum -Ip65 Bourdon: Ss 316 Movement :Ss 304 Stem, Bulb, Connection : Ss 316 Bulb Dia:12 Mm Entry: Mounting Bottom - Surface Tg Connection:1 / 4 Inch Npt ( M ) Capillary:10M-Ss 316 Capillary With Ss 304 Armour Compensation: Case Compensation Zero Adjustment: Micrometer Screw On Pointer Adjustable From Front Window: Shatterer Proof Glass Bore Dia: ( Bulb Dia+1 ) Mm L ( Mm ) , El ( Mm ) :Il- 125Mm, El 50Mm Instrument Connection On Thermowell: ¼ Inch Npt ( F ) Tip Dia:25Mm , Temperature Gauge ( 0-100° C ) Type: Inert Gas Temp Gauge ( Gas Tg ) Dial Size:150Mm Range : As Per Given Measurement Case: Die Cast Aluminum -Ip65 Bourdon: Ss 316 Movement :Ss 304 Stem, Bulb, Connection : Ss 316 Bulb Dia:12 Mm Entry: Mounting Bottom - Surface Tg Connection:1 / 4 Inch Npt ( M ) Capillary:10M-Ss 316 Capillary With Ss 304 Armour Compensation: Case Compensation Zero Adjustment: Micrometer Screw On Pointer Adjustable From Front Window: Shatterer Proof Glass Bore Dia: ( Bulb Dia+1 ) Mm Il ( Mm ) , El ( Mm ) :Il- 225Mm, El 50Mm Instrument Connection On Thermowell: ¼ Inch Npt ( F ) Tip Dia:25Mm , Temp. Gauge 0-500 Deg C Type: Inert Gas Temp Gauge ( Gas Tg ) Dial Size:150Mm Range : As Per Given Measurement Case: Die Cast Aluminum -Ip65 Bourdon: Ss 316 Movement :Ss 304 Stem, Bulb, Connection : Ss 316 Bulb Dia:12 Mm Entry: Mounting Bottom - Surface Tg Connection:1 / 4 Inch Npt ( M ) Capillary:10M-Ss 316 Capillary With Ss 304 Armour Compensation: Case Compensation Zero Adjustment: Micrometer Screw On Pointer Adjustable From Front Window: Shatterer Proof Glass Bore Dia: ( Bulb Dia+1 ) Mm L ( Mm ) , El ( Mm ) :Il- 175Mm, El 80Mm Instrument Connection On Thermowell: ¼ Inch Npt ( F ) Tip Dia:25Mm , Temp. Gauge 0-500 Deg C Type: Inert Gas Temp Gauge ( Gas Tg ) Dial Size:150Mm Range : As Per Given Measurement Case: Die Cast Aluminum -Ip65 Bourdon: Ss 316 Movement :Ss 304 Stem, Bulb, Connection : Ss 316 Bulb Dia:12 Mm Entry: Mounting Bottom - Surface Tg Connection:1 / 4 Inch Npt ( M ) Capillary:10M-Ss 316 Capillary With Ss 304 Armour Compensation: Case Compensation Zero Adjustment: Micrometer Screw On Pointer Adjustable From Front Window: Shatterer Proof Glass Bore Dia: ( Bulb Dia+1 ) Mm Il ( Mm ) , El ( Mm ) :Il- 150Mm, El 190Mm Instrument Connection On Thermowell: ¼ Inch Npt ( F ) Tip Dia:25Mm , Temp. Gauge 0-500 Deg C Type: Inert Gas Temp Gauge ( Gas Tg ) Dial Size:150Mm Range : As Per Given Measurement Case: Die Cast Aluminum -Ip65 Bourdon: Ss 316 Movement :Ss 304 Stem, Bulb, Connection : Ss 316 Bulb Dia:12 Mm Entry: Mounting Bottom - Surface Tg Connection:1 / 4 Inch Npt ( M ) Capillary:10M-Ss 316 Capillary With Ss 304 Armour Compensation: Case Compensation Zero Adjustment: Micrometer Screw On Pointer Adjustable From Front Window: Shatterer Proof Glass Bore Dia: ( Bulb Dia+1 ) Mm Il ( Mm ) , El ( Mm ) :Il- 100Mm, El 190Mm Instrument Connection On Thermowell: ¼ Inch Npt ( F ) Tip Dia:25Mm , Temp Gauge 0-300 Deg C Type: Inert Gas Temp Gauge ( Gas Tg ) Dial Size:150Mm Range : As Per Given Measurement Case: Die Cast Aluminum -Ip65 Bourdon: Ss 316 Movement :Ss 304 Stem, Bulb, Connection : Ss 316 Bulb Dia:12 Mm Entry: Mounting Bottom - Surface Tg Connection:1 / 4 Inch Npt ( M ) Capillary:10M-Ss 316 Capillary With Ss 304 Armour Compensation: Case Compensation Zero Adjustment: Micrometer Screw On Pointer Adjustable From Front Window: Shatterer Proof Glass Bore Dia: ( Bulb Dia+1 ) Mm Il ( Mm ) , El ( Mm ) :Il- 125Mm, El 50Mm Instrument Connection On Thermowell: ¼ Inch Npt ( F ) Tip Dia:25Mm , Temp Gauge 0-300 Deg C Type: Inert Gas Temp Gauge ( Gas Tg ) Dial Size:150Mm Range : As Per Given Measurement Case: Die Cast Aluminum -Ip65 Bourdon: Ss 316 Movement :Ss 304 Stem, Bulb, Connection : Ss 316 Bulb Dia:12 Mm Entry: Mounting Bottom - Surface Tg Connection:1 / 4 Inch Npt ( M ) Capillary:10M-Ss 316 Capillary With Ss 304 Armour Compensation: Case Compensation Zero Adjustment: Micrometer Screw On Pointer Adjustable From Front Window: Shatterer Proof Glass Bore Dia: ( Bulb Dia+1 ) Mm Il ( Mm ) , El ( Mm ) :Il- 100Mm, El 50Mm Instrument Connection On Thermowell: ¼ Inch Npt ( F ) Tip Dia:25Mm , Temp Gauge 0-300 Deg C Type: Inert Gas Temp Gauge ( Gas Tg ) Dial Size:150Mm Range : As Per Given Measurement Case: Die Cast Aluminum -Ip65 Bourdon: Ss 316 Movement :Ss 304 Stem, Bulb, Connection : Ss 316 Bulb Dia:12 Mm Entry: Mounting Bottom - Surface Tg Connection:1 / 4 Inch Npt ( M ) Capillary:10M-Ss 316 Capillary With Ss 304 Armour Compensation: Case Compensation Zero Adjustment: Micrometer Screw On Pointer Adjustable From Front Window: Shatterer Proof Glass Bore Dia: ( Bulb Dia+1 ) Mm Il ( Mm ) , El ( Mm ) :Il- 175Mm, El 105Mm Instrument Connection On Thermowell: ¼ Inch Npt ( F ) Tip Dia:25Mm , Temp Gauge 0-300 Deg C Type: Inert Gas Temp Gauge ( Gas Tg ) Dial Size:150Mm Range : As Per Given Measurement Case: Die Cast Aluminum -Ip65 Bourdon: Ss 316 Movement :Ss 304 Stem, Bulb, Connection : Ss 316 Bulb Dia:12 Mm Entry: Mounting Bottom - Surface Tg Connection:1 / 4 Inch Npt ( M ) Capillary:10M-Ss 316 Capillary With Ss 304 Armour Compensation: Case Compensation Zero Adjustment: Micrometer Screw On Pointer Adjustable From Front Window: Shatterer Proof Glass Bore Dia: ( Bulb Dia+1 ) Mm Il ( Mm ) , El ( Mm ) :Il- 150Mm, El 65Mm Instrument Connection On Thermowell: ¼ Inch Npt ( F ) Tip Dia:25Mm , Temp Gauge 0-120 Deg C Type: Inert Gas Temp Gauge ( Gas Tg ) Dial Size:150Mm Range : As Per Given Measurement Case: Die Cast Aluminum -Ip65 Bourdon: Ss 316 Movement :Ss 304 Stem, Bulb, Connection : Ss 316 Bulb Dia:12 Mm Entry: Mounting Bottom - Surface Tg Connection:1 / 4 Inch Npt ( M ) Capillary:10M-Ss 316 Capillary With Ss 304 Armour Compensation: Case Compensation Zero Adjustment: Micrometer Screw On Pointer Adjustable From Front Window: Shatterer Proof Glass Bore Dia: ( Bulb Dia+1 ) Mm Il ( Mm ) , El ( Mm ) :As Il-150Mm, El 50Mm Instrument Connection On Thermowell: ¼ Inch Npt ( F ) T , Temp Gauge 0-120 Deg C Type: Inert Gas Temp Gauge ( Gas Tg ) Dial Size:150Mm Range : As Per Given Measurement Case: Die Cast Aluminum -Ip65 Bourdon: Ss 316 Movement :Ss 304 Stem, Bulb, Connection : Ss 316 Bulb Dia:12 Mm Entry: Mounting Bottom - Surface Tg Connection:1 / 4 Inch Npt ( M ) Capillary:10M-Ss 316 Capillary With Ss 304 Armour Compensation: Case Compensation Zero Adjustment: Micrometer Screw On Pointer Adjustable From Front Window: Shatterer Proof Glass Bore Dia: ( Bulb Dia+1 ) Mm Il ( Mm ) , El ( Mm ) :Il- 250Mm, El 50Mm Instrument Connection On Thermowell: ¼ Inch Npt ( F ) Tip Dia:25Mm , Pressure Gauge 0 To 4 Kg / Cm Nominal Size: 100 Mm; Accuracy: Class 1 ( According En837-1 ) ; Protection Rating: Ip 65 ( En 60529 ) ; Service - Conveying Air; Mov Ement: Stainless Steel; Window: Instrument Glass; Window Gasket: Elastomer; Dial: Aluminium, White; Pointer: Aluminium, Black ; Temperature: Ambient : -20 ... +70°C; Type- Field Mounted; Overrange -130% ; Dial Size- 6; Process Connection- 1 / 2 Npt ( M ) Bottom Connection ; Accuracy- ± 1 %Of Fsd ; Case Material - Ss304 With Bayonet Bazel Weatherproof To Ip-65 With Blow Out Disc; Dial- Aluminium White Background, Black Marking < ( >&< ) > Zero Stop; Scale- Linear, 270 Degree Arc, Graduated In Metric Unit; Sensing Element- Ss316 Bourden ; Movement Material - Ss304; Socket Material - Ss316; Pointer- Aluminium, Black Painted With Micro Adjustable Facility , Pressure Gauge Ar-150; 0-10 Kg / Cm2 Specifications : Nominal Size: 100 Mm; Accuracy: Class 1 ( According En837-1 ) ; Protection Rating: Ip 65 ( En 60529 ) ; Service - Conveying Air; Mov Ement: Stainless Steel; Window: Instrument Glass; Window Gasket: Elastomer; Dial: Aluminium, White; Pointer: Aluminium, Black ; Temperature: Ambient : -20 ... +70°C; Type- Field Mounted; Overrange -130% ; Dial Size- 6; Process Connection- 1 / 2 Npt ( M ) Bottom Connection ; Accuracy- ± 1 %Of Fsd ; Case Material - Ss304 With Bayonet Bazel Weatherproof To Ip-65 With Blow Out Disc; Dial- Aluminium White Background, Black Marking < ( >&< ) > Zero Stop; Scale- Linear, 270 Degree Arc, Graduated In Metric Unit; Sensing Element- Ss316 Bourden ; Movement Material - Ss304; Socket Material - Ss316; Pointer- Aluminium, Black Painted With Micro Adjustable Facility , Pressure Gauge 0-20 Kg / Cm2 Specifications : Nominal Size: 100 Mm; Accuracy: Class 1 ( According En837-1 ) ; Protection Rating: Ip 65 ( En 60529 ) ; Service - Conveying Air; Mov Ement: Stainless Steel; Window: Instrument Glass; Window Gasket: Elastomer; Dial: Aluminium, White; Pointer: Aluminium, Black ; Temperature: Ambient : -20 ... +70°C; Type- Field Mounted; Overrange -130% ; Dial Size- 6; Process Connection- 1 / 2 Npt ( M ) Bottom Connection ; Accuracy- ± 1 % Of Fsd ; Case Material - Ss304 With Bayonet Bazel Weatherproof To Ip-65 With Blow Out Disc; Dial- Aluminium White Background, Black Marking < ( >&< ) > Zero Stop; Scale- Linear, 270 Degree Arc, Graduated In Metric Unit; Sensing Element- Ss316 Bourden ; Movement Material - Ss304; Socket Material - Ss316; Pointer- Aluminium, Black Painted With Micro Adjustable Facility , Pressure Gauges ( 0-2.5 ) Kg / Cm2 Specifications : Nominal Size: 100 Mm; Accuracy: Class 1 ( According En837-1 ) ; Protection Rating: Ip 65 ( En 60529 ) ; Service - Conveying Air; Mov Ement:Stainless Steel; Window: Instrument Glass; Window Gasket: Elastomer; Dial: Aluminium, White; Pointer: Aluminium, Black ; Temperature: Ambient : -20 ... +70°C; Type- Field Mounted; Overrange -130% ; Dial Size- 6; Process Connection- 1 / 2 Npt ( M ) Bottom Connection ; Accuracy- ± 1 %Of Fsd ; Case Material - Ss304 With Bayonet Bazel Weatherproof To Ip-65 With Blow Out Disc; Dial- Aluminium White Background, Black Marking < ( >&< ) > Zero Stop; Scale- Linear, 270 Degree Arc, Graduated In Metric Unit; Sensing Element- Ss316 Bourden ; Movement Material - Ss304; Socket Material - Ss316; Pointer- Aluminium, Black Painted With Micro Adjustable Facility , Pressure Gauge 0-25 Kg / Cm2 Specifications : Nominal Size: 100 Mm; Accuracy: Class 1 ( According En837-1 ) ; Protection Rating: Ip 65 ( En 60529 ) ; Service - Conveying Air; Mov Ement: Stainless Steel; Window: Instrument Glass; Window Gasket: Elastomer; Dial: Aluminium, White; Pointer: Aluminium, Black ; Temperature: Ambient : -20 ...+70°C; Type- Field Mounted; Overrange -130% ; Dial Size- 6; Process Connection- 1 / 2 Npt ( M ) Bottom Connection ; Accuracy- ± 1 %Of Fsd ; Case Material - Ss304 With Bayonet Bazel Weatherproof To Ip-65 With Blow Out Disc; Dial- Aluminium White Background, Black Marking < ( >&< ) > Zero Stop; Scale- Linear, 270 Degree Arc, Graduated In Metric Unit; Sensing Element- Ss316 Bourden ; Movement Material - Ss304; Socket Material - Ss316; Pointer-Aluminium, Black Painted With Micro Adjustable Facility , Pressure Gauge 0-4 Kg / Cm² Specifications : Nominal Size: 100 Mm; Accuracy: Class 1 According En837-1 ) ; Protection Rating: Ip 65 ( En 60529 ) ; Service - Conveying Air; Movement: Stainless Steel; Window: Instrument Glass; Window Gasket: Elastomer; Dial: Aluminium, White; Pointer: Aluminium, Black ; Temperature: Ambient : -20 ... +70°C; Type- Field Mounted; Overrange -130% ; Dial Size- 6; Process Connection- 1 / 2 Npt ( M ) Bottom Connection ; Accuracy- ± 1 %Of Fsd ; Case Material - Ss304 With Bayonet Bazel Weatherproof To Ip-65 With Blow Out Disc; Dial- Aluminium White Background, Black Marking < ( >&< ) > Zero Stop; Scale- Linear, 270 Degree Arc, Graduated In Metric Unit; Sensing Element- Ss316 Bourden ; Movement Material - Ss304; Socket Material - Ss316; Pointer- Aluminium, Black Painted With Micro Adjustable Facility , Pressure Gauge 0-6 Kg / Cm2 Specifications : Nominal Size: 100 Mm; Accuracy: Class 1 ( According En837-1 ) ; Protection Rating: Ip 65 ( En 60529 ) ; Service - Conveying Air; Mov Ement: Stainless Steel; Window: Instrument Glass; Window Gasket: Elastomer; Dial: Aluminium, White; Pointer: Aluminium, Black ; Temperature: Ambient : -20 ... +70°C; Type- Field Mounted; Overrange -130% ; Dial Size- 6; Process Connection- 1 / 2 Npt ( M ) Bottom Connection ; Accuracy- ± 1 %Of Fsd ; Case Material - Ss304 With Bayonet Bazel Weatherproof To Ip-65 With Blow Out Disc; Dial- Aluminium White Background, Black Marking < ( >&< ) > Zero Stop; Scale- Linear, 270 Degree Arc, Graduated In Metric Unit; Sensing Element- Ss316 Bourden ; Movement Material - Ss304; Socket Material - Ss316; Pointer- Aluminium, Black Painted With Micro Adjustable Facility , Pressure Gauge 0-16 Kg / Cm2 Specifications: Nominal Size: 100 Mm; Accuracy: Class 1 ( According En837-1 ) ; Protection Rating: Ip 65 ( En 60529 ) ; Service - Conveying Air; Mov Ement: Stainless Steel; Window: Instrument Glass; Window Gasket: Elastomer; Dial: Aluminium, White; Pointer: Aluminium, Black ; Temperature: Ambient : -20 ... +70°C; Type- Field Mounted; Overrange -130% ; Dial Size- 6; Process Connection- 1 / 2 Npt ( M ) Bottom Connection ; Accuracy- ± 1 %Of Fsd ; Case Material - Ss304 With Bayonet Bazel Weatherproof To Ip-65 With Blow Out Disc; Dial- Aluminium White Background, Black Marking < ( >&< ) > Zero Stop; Scale- Linear, 270 Degree Arc, Graduated In Metric Unit; Sensing Element- Ss316 Bourden ; Movement Material - Ss304; Socket Material - Ss316; Pointer- Aluminium, Black Painted With Micro Adjustable Facility , Press Gauge 0-280 Kg / Cm2 1 / 4 Inch Bsp, Center Back Entry, 63Mm Dial Size , Liquid Filled , Pressure Gauge 0-280 1 / 4 Inch Bsp, Bottom Entry, 63Mm Dial Size , Liquid Filled , Solid Front Bourdon Sensing Pressure Guage 0-250 Pecifications: Nominal Size: 100 Mm; Accuracy: Class 1 ( According En837-1 ) ; Protection Rating: Ip 65 ( En 60529 ) ; Service - Conveying Air; Mov Ement: Stainless Steel; Window: Instrument Glass; Window Gasket: Elastomer; Dial: Aluminium, White; Pointer: Aluminium, Black ; Temperature: Ambient : -20 ... +70°C; Type- Field Mounted; Overrange -130% ; Dial Size- 6; Process Connection- 1 / 2 Npt ( M ) Bottom Connection ; Accuracy- ± 1 %Of Fsd ; Case Material - Ss304 With Bayonet Bazel Weatherproof To Ip-65 With Blow Out Disc; Dial- Aluminium White Background, Black Marking < ( >&< ) > Zero Stop; Scale- Linear, 270 Degree Arc, Graduated In Metric Unit; Sensing Element- Ss316 Bourden ; Movement Material - Ss304; Socket Material - Ss316; Pointer- Aluminium, Black Painted With Micro Adjustable Facility , Pressure Gauge 0-200 Pecifications: Nominal Size: 100 Mm; Accuracy: Class 1 ( According En837- 1 ) ; Protection Rating: Ip 65 ( En 60529 ) ; Service - Conveying Air; Mov Ement: Stainless Steel; Window: Instrument Glass; Window Gasket: Elastomer; Dial: Aluminium, White; Pointer: Aluminium, Black ; Temperature: Ambient : -20 ... +70°C; Type- Field Mounted; Overrange -130% ; Dial Size- 6; Process Connection- 1 / 2 Npt ( M ) Bottom Connection ; Accuracy- ± 1 %Of Fsd ; Case Material - Ss304 With Bayonet Bazel Eatherproof To Ip-65 With Blow Out Disc; Dial- Aluminium White Background, Black Marking < ( >&< ) > Zero Stop; Scale- Linear, 270 Degree Arc, Graduated In Metric Unit; Sensing Element- Ss316 Bourden ; Movement Material - Ss304; Socket Material - Ss316; Pointer- Aluminium, Black Painted With Micro Adjustable Facility , Pressure Gauge Ar-150; 0-60 Kg / Cm2 Pecifications: Nominal Size: 100 Mm; Accuracy: Class 1 ( According En837-1 ) ; Protection Rating: Ip 65 ( En 60529 ) ; Service - Conveying Air; Mov Ement: Stainless Steel; Window: Instrument Glass; Window Gasket: Elastomer; Dial: Aluminium, White; Pointer: Aluminium, Black ; Temperature: Ambient : -20 ... +70°C; Type- Field Mounted; Overrange -130% ; Dial Size- 6; Process Connection- 1 / 2 Npt ( M ) Bottom Connection ; Accuracy- ± 1 %Of Fsd ; Case Material - Ss304 With Bayonet Bazel Weatherproof To Ip-65 With Blow Out Disc; Dial- Aluminium White Background, Black Marking < ( >&< ) > Zero Stop; Scale- Linear, 270 Degree Arc, Graduated In Metric Unit; Sensing Element- Ss316 Bourden ; Movement Material - Ss304; Socket Material - Ss316; Pointer- Aluminium, Black Painted With Micro Adjustable Facility , Pressure Gauge Glycerin Filed Ss In Casing Dia Size 4 100 Mm Range 0 To 25Kg / Cm2 Specifications : Nominal Size: 100 Mm; Accuracy: Class 1 ( According En837-1 ) ; Protection Rating: Ip 65 ( En 60529 ) ; Service - Conveying Air; Mov Ement: Stainless Steel; Window: Instrument Glass; Window Gasket: Elastomer; Dial: Aluminium, White; Pointer: Aluminium, Black ; Temperature: Ambient: -20 ... +70°C; Type- Field Mounted; Overrange -130% ; Dial Size- 6; Process Connection- 1 / 2 Npt ( M ) Bottom Connection ; Accuracy- ± 1 %Of Fsd ; Case Material - Ss304 With Bayonet Bazel Weatherproof To Ip-65 With Blow Out Disc; Dial- Aluminium White Background, Black Marking < ( >&< ) > Zero Stop; Scale- Linear, 270 Degree Arc, Graduated In Metric Unit; Sensing Element- Ss316 Bourden ; Movement Material - Ss304; Socket Material - Ss316; Pointer- Aluminium, Black Painted With Micro Adjustable Facility , Glycerin Filed , Pressure Gauge Glycerin Filed Ss In Casing Dia Size 4 100 Mm Range 0 To 6 Kg / Cm2 Specifications : Nominal Size: 100 Mm; Accuracy: Class 1 ( According En837-1 ) ; Protection Rating: Ip 65 ( En 60529 ) ; Service - Conveying Air; Mov Ement: Stainless Steel; Window: Instrument Glass; Window Gasket: Elastomer; Dial: Aluminium, White; Pointer: Aluminium, Black ; Temperature: Ambient : -20 ... +70°C; Type- Field Mounted; Overrange -130% ; Dial Size- 6; Process Connection- 1 / 2 Npt ( M ) Bottom Connection ; Accuracy- ± 1 %Of Fsd ; Case Material - Ss304 With Bayonet Bazel Weatherproof To Ip-65 With Blow Out Disc; Dial- Aluminium White Background, Black Marking < ( >&< ) > Zero Stop; Scale- Linear, 270 Degree Arc, Graduated In Metric Unit; Sensing Element-Ss316 Bourden ; Movement Material - Ss304; Socket Material - Ss316; Pointer- Aluminium, Black Painted With Micro Adjustable Facility , Glycerin Filed , Pressure Gauge Glycerin Filed Ss In Casing Dia Size 4 100 Mm Range 0 To 60 Kg / Cm2 Specifications : Nominal Size: 100 Mm; Accuracy: Class 1 ( According En837-1 ) ; Protection Rating: Ip 65 ( En 60529 ) ; Service - Conveying Air; Mov Ement: Stainless Steel; Window: Instrument Glass Window Gasket: Elastomer; Dial: Aluminium, White; Pointer: Aluminium, Black ; Temperature: Ambient : -20 ... +70°C; Type- Field Mounted; Overrange -130% ; Dial Size- 6; Process Connection- 1 / 2 Npt ( M ) Bottom Connection ; Accuracy- ± 1 %Of Fsd ; Case Material - Ss304 With Bayonet Bazel Weatherproof To Ip-65 With Blow Out Disc; Dial- Aluminium White Background, Black Marking < ( >& < ) > Zero Stop; Scale- Linear, 270 Degree Arc, Graduated In Metric Unit; Sensing Element- Ss316 Bourden ; Movement Material - Ss304; Socket Material - Ss316; Pointer- Aluminium, Black Painted With Micro Adjustable Facility , Glycerin Filed. , Differential Pressure Guage ( Dad-00706 ) Range: 0 To 1.6 Bar , Mill Thrust Pad Temp. Rtd Along With Transmitter, Range:0-100 0C El: 310, Head Mounted Transmitter, , Pressure Gauge Ar-150; 0-10 Kg / Cm2specification : Pressure Gauge 0-200 Pecifications:# Nominal Size: 100 Mm; Accuracy: Class 1 ( According En837-1 ) ; Protection Rating: Ip 65 ( En 60529 ) ; Service - Conveying Air; Movement: Stainless Steel; Window: Instrument Glass; Window Gasket: Elastomer; Dial: Aluminium, Hite; Pointer: Aluminium, Black ; Temperature: Ambient : -20 ... +70°C; Type- Field Mounted; Overrange -130% ; Dial Size- 6; Process Connection- 1 / 2 Npt ( M ) Bottom Connection ; Accuracy- ± 1 %Of Fsd ; Case Material - Ss304 With Bayonet Bazel Weatherprof To Ip-65 With Blow Out Disc; Dial- Aluminium White Background, Black Marking < ( >&< ) > Zero Stop; Scale- Linear, 270 Degree Arc, Graduated In Metric Unit; Sensing Element- Ss316 Bourden ; Movement Material - Ss304; Socket Material - Ss316; Pointer Aluminium, B Ack Painted With Micro Adjustable Facility , Pressure Gauge 0 To 25 Kg Cm2specification : Pressure Gauge 0-200 Pecifications:# Nominal Size: 100 Mm; Accuracy: Class 1 ( According En837-1 ) ; Protection Rating: Ip 65 ( En 60529 ) ; Service - Conveying Air; Movement: Stainless Steel; Window: Instrument Glass; Window Gasket: Elastomer; Dial: Aluminium, Hite; Pointer: Aluminium, Black ; Temperature: Ambient : -20 ...+70°C; Type- Field Mounted; Overrange -130% ; Dial Size- 6; Process Connection- 1 / 2 Npt ( M ) Bottom Connection ; Accuracy- ± 1 %Of Fsd ; Case Material - Ss304 With Bayonet Bazel Weatherpro F To Ip-65 With Blow Out Disc; Dial- Aluminium White Background, Black Marking < ( >&< ) > Zero Stop; Scale- Linear, 270 Degree Arc, Graduated In Metric Unit; Sensing Element- Ss316 Bourden ; Movement Material - Ss304; Socket Material - Ss316; Pointer Aluminium, B Ack Painted With Micro Adjustable Facility , Pressure Gauge Glycerin Filed Ss In Casing Dia Size 4 100 Mm Range 0 To 25Kg / Cm2 Specifications : Nominal Size: 100 Mm; Accuracy: Class 1 ( According En837-1 ) ; Protection Rating: Ip 65 ( En 60529 ) ; Service - Conveying Air; Mov Ement: Stainless Steel; Window: Instrument Glass; Window Gasket: Elastomer; Dial: Aluminium, White; Pointer: Aluminium, Black ; Temperature: Ambient: -20 ... +70°C; Type- Field Mounted; Overrange -130% ; Dial Size- 6; Process Connection- 1 / 2 Npt ( M ) Bottom Connection ; Accuracy- ± 1 %Of Fsd ; Case Material - Ss304 With Bayonet Bazel Weatherproof To Ip-65 With Blow Out Disc; Dial- Aluminium White Background, Black Marking < ( >&< ) > Zero Stop; Scale- Linear, 270 Degree Arc, Graduated In Metric Unit; Sensing Element- Ss316 Bourden ; Ovement Material - Ss304; Socket Material - Ss316; Pointer- Aluminium, Black Painted With Micro Adjustable Facility , Glycerin Filed , Pressure Gauge Glycerin Filed Ss In Casing Dia Size 4 100 Mm Range 0 To 10 Kg / Cm2 Specifications : Nominal Size: 100 Mm; Accuracy: Class 1 ( According En837-1 ) ; Protection Rating: Ip 65 ( En 60529 ) ; Service - Conveying Air; Mov Ement: Stainless Steel; Window: Instrument Glass; Window Gasket: Elastomer; Dial: Aluminium, White; Pointer: Aluminium, Black ; Temperature: Ambient: -20 ... +70°C; Type- Field Mounted; Overrange -130% ; Dial Size- 6; Process Connection- 1 / 2 Npt ( M ) Bottom Connection ; Accuracy- ± 1 %Of Fsd ; Case Material - Ss304 With Bayonet Bazel Weatherproof To Ip-65 With Blow Out Disc; Dial- Aluminium White Background, Black Marking < ( >&< ) > Zero Stop; Scale- Linear, 270 Degree Arc, Graduated In Metric Unit; Sensing Element- Ss316 Bourden ; Movement Material - Ss304; Socket Material - Ss316; Pointer- Aluminium, Black Painted With Micro Adjustable Facility , Glycerin Filed , Temperature Gauge ( 0-120° C ) Application:-Metal,
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 5
Uttar Pradesh View Result →
TenderDetail
Loading tenders