View Bid Results For Development Mechanism Tenders

We found 303 Bid Results related to development mechanism tenders. You can find Contractor details who won development mechanism tenders along with contract details in Bid awards announcements section.

Filters
Stage
211
71
21
Tender Publishing Platform
67
236
State / UT
25
61
48
34
22
21
18
17
13
9
8
7
6
5
5
4
4
4
3
3
3
2
2
2
1
1
Contract Value
100
67
77
58
Publish Date
0
0
0
0
0
Sector
22
77
46
39
32
23
20
12
9
6
6
5
5
4
4
3
3
3
2
1
1
1
1
Ownership
5
149
80
44
29
1
Within keyword
Active filters:
Showing 1–7 of 303 tenders matching your filters
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
2.
Railways #11404973 AOC
Supply Of Eot Crane 50/10 Ton Capacityeot Crane 50/10 Ton Capacity,Cost Of Electric Over Head Travelling Crane Capacity -50/10 Ton With Remote Control And Ds L Length Of 140 Mts And All Spares And Accessories As Per Detailed Technical Specification Enclosed. [ Wa Rranty Period: 24 Months After The Date Of Delivery ] ] , Cost Of Any Other Accessories Treated As Concomitant Accessories. ] , Camc Charges For 5 Years After Completion Of Warranty Period. Refer Respective Bid Docume Nt. [ Warranty Period: 2 Years, Amc Period: 5 Years, Rate Of Discounting: 10 % ] ] At (Location) Sse/Els/Ajj, Sr Tamil Nadu 1.00 Numbers 4 6579Ns02 Essential Non Stock --- Yes Tpi Agency Inr (Grp1) Spares (Y) Cost Of Dsl (Type And Length Of Dsl As Specified In Schedule-L) ] Consignee Sse/Els/Ajj, Sr Tamil Nadu 1.00 Set Inspection Details Stage Inspection Not Required Page 1 Of 15 Run Date/Time: 27/05/2025 11:07:29Stores/Southern Rly Tender Document Tender No 16255008 Closing Date/Time 30/06/2025 14:30 5 6579Ns03 Essential Non Stock --- Yes Tpi Agency Inr (Grp1) Spares (Y) Cost Of Spares As Per Schedule-Iv & Additional Spares And Items As Specified In Schedule-I. ] Consignee Sse/Els/Ajj, Sr Tamil Nadu 1.00 Set Inspection Details Stage Inspection Not Required 6 6579Ns04 Essential Non Stock --- Yes Tpi Agency Inr (Grp1) Spares (Y) Cost Of Maintenance Tools As Per Schedule-V ] Consignee Sse/Els/Ajj, Sr Tamil Nadu 1.00 Set Inspection Details Stage Inspection Not Required 7 6579Ser1 Essential Non Stock --- Yes Consignee Inr (Grp1) Services (Y) Cost Of Installation & Commissioning Of Crane And Dsl (Length Of Dsl As Specified In Schedule -L). ] At (Location) Sse/Els/Ajj, Sr Tamil Nadu 1.00 Numbers 8 6579Ser2 Essential Non Stock --- Yes Consignee Inr (Grp1) Services (Y) Cost Of Preventive Maintenance During 1St & 2Nd Year Of Warranty Period ] At (Location) Sse/Els/Ajj, Sr Tamil Nadu 1.00 Numbers 3. T And C F.O.R Description Destination Delivery Period Description Delivery /Completion Rate Of Supply For All Items Commencement : Within 4 Months Of Issue Of Contract, However, Delivery Completion : Within 6 Months Thereafter Period Shall Not Exceed No. Of Days As Mentioned In Delivery Schedule Chart Of Para 7 Of Section Iv Of Respective Bid Document Part Ii. However, The Delivery Period Indicated Being Tentative, May Vary At The Time Of Placement Of Order. Payment Terms S.No Description Payment Terms 1 1) 60% Payment: Upon Receipt Of The M&P, Duly Pre-Inspected By A Third -Party Inspection (Tpi) Agency, Receipted At The Site By The Consignee In Good Condition And Submission Of A Joint Receipt Note. 2) 20% Intermediate Payment: After Successful Installation And Commissioning And Submission Of A Joint Commissioning Note. 3) Final 20% Payment: After Commissioning Of The M&P At The Consignees End For A Minimum Period Of 30 Days, Upon Submission Of A 10% Warranty Bank Guarantee And A Proving Test Certificate Statutory Variation Clause S.No Description Page 2 Of 15 Run Date/Time: 27/05/2025 11:07:29Stores/Southern Rly Tender Document Tender No 16255008 Closing Date/Time 30/06/2025 14:30 1 Statutory Variation In Taxes And Duties, Or Fresh Imposition Of Taxes And Duties By State/ Central Governments In Respect Of The Items Stipulated In The Contract (And Not The Raw Materials Thereof), Within The Original Delivery Period Stipulated In The Contract, Or Last Unconditionally Extended Delivery Period Shall Be To Railways Account. Only Such Variation Shall Be Admissible Which Takes Place After The Submission Of Bid. No Claim On Account Of Statutory Variation In Respect Of Existing Tax/Duty Will Be Accepted Unless The Tenderer Has Clearly Indicated In His OffEr The Rate Of Tax/Duty Considered In His Quoted Rate. No Claim On Account Of Statutory Variation Shall Be Admissible On Account Of Misclassiï¬Cation By The Supplier/ Contractor. Standard Governing Conditions S.No Description 1 The Bidder Agrees To Supply The Tendered Stores At The Rates Quoted By Him In Accordance With The Latest Version Of Irs Conditions Of Contract (Attached As Irs Conditions Of Contract To This Tender Document For Ready Reference) And Southern Railway Tender Conditions (Attached As Sr Tender Conditions To This Tender Document For Ready Reference). 4. Eligibility Conditions Special Eligibility Criteria S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Supply To Be Strictly As Per Speciï¬Cations Normal Applicable To Yes Yes Not Allowed Documents Uploaded With This Tender. All Bidders Please Refer Bid Document Part Ii. 2 The Bidder / Manufacturer Should Have Normal Applicable To Yes Yes Allowed Supplied At Least 3 (Three) Eot Cranes All Bidders (Mandatory) During The Last 5 (ϬVe) Years (Reckoned From The Original Closing Date Of The Tender) In The Contracts Concluded By Railways / Cofmow. 3 Preferably Manufacturers Should Normal Applicable To Yes Yes Allowed Participate. Participating Traders/Agents All Bidders (Optional) Must Attach Authorization Letter Issued By The Oem Or Oem Authorized Stockiest Along With Their OffEr. Authorization Letter Should Preferably Be Tender Speciï¬C. In Case Of General Authorization Letter, It Must Clearly Indicate The Validity Period/Expiry Date. OffErs With General Authorization Letter Silent On Validity Period/Expiry Date Will Not Be Considered For Placement Of Order And That OffEr Is Liable To Be Ignored. (Please Refer Para 3.4 Of Part B Of Sr Tender Conditions). 4 Procurement Of The Item Is Restricted To Normal Applicable To Yes Yes Not Allowed Local Suppliers With Minimum Local All Bidders Content Of 20% (Class-I Or Class-Ii Local Supplier As Deï¬Ned In Railway Board Letter No.2020/Rs(G)/779/2/Pt.1 Dated 25.09.2020 With Latest Amendments, If Any) Only And The Vendors Who Do Not Qualify To Be Local Suppliers (I.E.), Non- Local Suppliers With Local Content Less Than 20%) Should Not Quote In The Tender As Their OffErs Shall Not Be Considered For Any Ordering. In Case Any Vendor Who Does Not Qualify To Be A Local Supplier For The Tendered Item Participates In The Tender, It Does So At Its Own Risk And Cost And Railways Shall Not Be Liable For Any Loss Or Damage Caused To The Vendor. OffEr Of The ϬRm Shall Be Summarily Rejected In Case Of Non-Compliance Of Above Declaration. For More Details, The Tenderer Shall Refer Para 16.0 Of Part B Of Sr Tender Conditions Attached To This Tender Document. Page 3 Of 15 Run Date/Time: 27/05/2025 11:07:29Stores/Southern Rly Tender Document Tender No 16255008 Closing Date/Time 30/06/2025 14:30 5 Earnest Money Deposit (Emd) Shall Be Normal Applicable To Yes Yes Not Allowed Deposited By All Vendors For Tenders With All Bidders Estimated Value Above Rs.25 Lakhs Subject To The Applicable Exemptions. The Para 2.1 Of The Part A Of Sr Tender Conditions With Regard To Emd Exemption Is Superseded As Below And The Conditions Mentioned Here Below Will Prevail Over That Of In Para 2.1 Of The Part A Of Sr Tender Conditions Attached To This Tender Document: Emd Amount Shall Be Mentioned In All Tenders Irrespective Of The Nature Of Tender As Per The Emd Amount Mentioned In Clause 2.3 Of Part A Of Sr Tender Conditions Or As Decided By The Purchaser Under The Policy. There Shall Be No Exemption From Submission Of Emd For Any Tender Or By Any Tenderer Subject To Provisions Under Clause 10.4.3 Of Part A Of Sr Tender Conditions Except Following : (I) Emd Shall Normally Not Be Called Against Tenders With Estimated Value Up To Rs.25 Lakhs (Including Single Tenders, Global Limited Tenders) Except Cases Where Competent Authority Incorporates The Condition To Call For Emd. Ii) Public Sector Undertakings (Psus) A. Psus Owned By Ministry Of Railways And B. Psus For The Group Of Items That Are Manufactured By Them. Iii) Mses Registered Under Udyam Registration Shall Be Eligible For Exemption From Payment Of Emd Irrespective Of Relevance Of Product Category For Which They Are Registered With Udyam. However, Traders/Distributors/Sole Agent/Works Contract Are Not Exempted From Payment Of Emd As They Are Excluded From The Purview Of The Policy. Iv) Other Railways, Indian Ordinance Factories And Govt. Departments. V) In Exceptional Cases, Where Emd Exemption Is Speciï¬Cally Incorporated In Tender Conditions. Vi) Vendors Registered With Southern Railway For The Trade Group/Trade Groups Of The Tendered Item . Vii) Regular And Development Vendors Appearing On The Approved Vendor Lists Of Rdso/Pus/ Core Etc., For Those Speciï¬C Item For Which They Are On The Approved List, Subject To Approval Status Being Valid On The Date Of Tender Closing. Viii) Vendors Registered With Railways For Supply Of Medicine, Medical Equipments And Consumables Shall Be Exempted From Submission Of Emd For These Items. Ix) In Tenders Issued Against Pac, Oem In Whose Favour Pac Has Been Issued Shall Be Exempted From Submitting Emd. Kvic And Acash Shall Be Exempted From Emd For Items Supplied By Them. In Case Of Submission Of Earnest Money Deposit In The Form Of Bank Guarantee, Please Refer Annexure- 6 Of Sr Tender Conditions For The Proforma For Bg. Page 4 Of 15 Run Date/Time: 27/05/2025 11:07:29Stores/Southern Rly Tender Document Tender No 16255008 Closing Date/Time 30/06/2025 14:30 6 All The Tenderers Shall Have To Submit Normal Applicable To Yes Yes Allowed Clause-Wise Compliance Of Speciï¬Cation All Bidders (Mandatory) Mentioned In Bid Document Part I & Part Ii (A&B) And Drawings Enclosed Along With This Tender Or Product Catalogue For The Make And Model OffEred Should Be Submitted By The Tenderer, Spelling Out Deviations, If Any, To Ascertain Technical Suitability. An OffEr, Whose Technical Suitability Cannot Be Ascertained, May Be Liable To Be Ignored. 7 Inter - Se Position Of Offers Would Normal Applicable To Yes Yes Not Allowed Be Determined Based On The Sum Of All Bidders Basic Cost Of The Equipment, Cost Of Any Other Accessories Treated As Concomitant Accessory, Cost Of Dsl, Cost Of Spares As Per Schedule - Iv Of And Additional Spares And Items As Specified In Section I, Cost Of Maintenance Tools As Per Schedule V, Cost Of Installation & Commissioning Of Crane And Dsl,Cost Of Preventive Maintenance For 2 Years And Camc Charges For 5 Years After Completion Of Warranty Period. 8 Firms Have To Quote All The Line Items. It Is Normal Applicable To Yes Yes Not Allowed Mandatory To Submit OffErs Against All All Bidders These Items, Otherwise OffEr Will Not Be Considered For Inter-Se Ranking. However, Please Note That Cost Of Optional Accessories Shall Not Be Included In The Basic Price Of The Machine For Inter-Se Ranking. 5. Compliance Conditions Check List S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Have You Quoted Cost Of Basic Machine, Normal Applicable To No No Not Allowed Concomitant Accessories/Equipment, All Bidders Essential Spares, Optional Accessories,Essential Services, Amc Service, Training Etc. It Is Mandatory To Submit OffErs Against All These Items, Otherwise OffEr Will Not Be Considered For Inter-Se Ranking. 2 Have You Attached Documents To Prove Normal Applicable To No No Not Allowed Your Eligibility And Past Performance As All Bidders Per Tender Requirement? 3 Have You Attached Certiï¬Cation Of Local Normal Applicable To No No Not Allowed Content From Statutory Auditor/ Cost All Bidders Accountant? 4 Have You Quoted Warranty Oblications As Normal Applicable To No No Not Allowed Per Tender Requirement? All Bidders 5 Have You Quoted Delivery Period Correctly Normal Applicable To No No Not Allowed And Precisely? All Bidders 6 Have You Uploaded Annexure A As In Normal Applicable To No No Not Allowed Section Vi And Other Required Documents, All Bidders Complete In All Respect? 7 Have You Submitted All Supporting Normal Applicable To No No Not Allowed Documents Required? All Bidders Page 5 Of 15 Run Date/Time: 27/05/2025 11:07:29Stores/Southern Rly Tender Document Tender No 16255008 Closing Date/Time 30/06/2025 14:30 8 Have You Read The Security Deposit (Sd) Normal Applicable To No No Not Allowed Condition At Para 10 Of Part A Of Sr All Bidders Tender Conditions Attached With This Tender Document And Uploaded Relevant Document For Seeking Exemption From Submission Of Sd? If Not, Are You Ready To Pay Security Deposit? 9 Are You Coming Under Mse Status Given Normal Applicable To No No Not Allowed As Per Guidelines Issued By Railway Board All Bidders For Purchase Preference Vide Letter No. 2010-Rs [G] -363-1 Dt. 05.07.2012 Or Latest. If Yes,Have You Attached Valid Documents (Udyam Registration Certificate) Towards Being Mse? 10 Have You Furnished The Statement Of Normal Applicable To No No Not Allowed Deviations?[Preferably Nil] All Bidders 11 Have You Quoted The Discount If Any In The Normal Applicable To No No Not Allowed Specified Column Only In Ireps? All Bidders 12 Have You Furnished Bank Account Details Normal Applicable To No No Not Allowed Such As Name Of The Bank And Address, All Bidders Account No., Micr, Ifsc Code And Type Of Account To Facilitate Eft Payment? 13 Please Check Our Website Before Normal Applicable To No No Not Allowed Submitting OffEr, Whether Any All Bidders Corrigendum To The Tender Has Been Issued Or Not. 14 Firm To Indicate Make-Model-Brand Normal Applicable To No No Not Allowed Offered, If Any. All Bidders 15 Have You Kept Your OffEr Valid For 120 Normal Applicable To No No Not Allowed Days? All Bidders Commercial-Compliance S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 In Case Of Road Delivery, The Date Of Normal Applicable To Yes Yes Not Allowed Delivery At Destination [Consignees End] All Bidders Shall Only Be Treated As Delivery Date Irrespective Of F.O.R. / F.O.T. Condition Mentioned Elsewhere In The Contract / Tender. 2 Tenderers May Note That Their OffEred Normal Applicable To Yes Yes Not Allowed Delivery Schedule Should Clearly Indicate All Bidders The Starting Time, Quarterly Rate Of Supply And ϬNishing Time. For OffErs With Vague Delivery Schedule Like -02 To 12 Months- Or Like -06 To 10 Months-, Delivery Period Shall Be Given As Per The Requirement Best Suited To This Oï¬Ƒce Within The Quoted Range. 3 The Bidder Conï¬Rms That Rates And Other Normal Applicable To Yes Yes Not Allowed ϬNancial Terms Quoted In Relevant All Bidders Columns Of ϬNancial Bid Will Only Be Ruling Terms For Acceptance, And Such Terms Quoted Anywhere Else Should Be Ignored. However, Break Up Of Cost Of Individual Items As Per Schedule- Iv And Additional Spares And Items As Speciï¬Ed In Schedule- L Is To Be Attached Separately. If Break-Up Of Cost List Is Not Uploaded, Whole Offer Will Be Ignored. Page 6 Of 15 Run Date/Time: 27/05/2025 11:07:29Stores/Southern Rly Tender Document Tender No 16255008 Closing Date/Time 30/06/2025 14:30 4 Whenever Tender Is Ϭ‚Oated With Purchase Normal Applicable To Yes Yes Not Allowed Restriction From Sources Approved By All Bidders Nominated Authorities And There Exists A Suspected Cartel Situation By Approved Sources Or The Rates Available From Approved Source/Sources Are Adjudged Unreasonably High, Despite Fair EffOrts As Permissible, The Purchaser Reserves The Right To Place Orders On ϬRm(S) Outside The Approved Vendor List, Without Any Restrictions.(Please Refer Para 4.0 Of Part B Of Sr Tender Conditions Document Attached To This Tender Document For Further Details.) 5 Hsn Code 8426 Normal Applicable To Yes Yes Not Allowed [A] All The Bidders/Tenderers Should Ensure All Bidders That They Are Gst Compliant And Their Quoted Tax Structure/Rates Are As Per The Gst Law. Firms Must Indicate Its Gst Registration Number Along With Their Offer. [B] In Case The Successful Tenderer Is Not Liable To Be Registered Under Cgst/Igst /Utgst/Sgst Act, The Railway Shall Deduct The Applicable Gst From His/Their Bills Under Reverse Charge Mechanism (Rcm) And Deposit The Same To The Concerned Tax Authority. [C] The ϬRm Should Indicate The Tariff Code (Hsn Code) For Claiming Gst For The Tendered Item. [D] The OffEr Shall Be Evaluated Based On The Gst Rate As Quoted By Each Bidder And Same Will Be Used For Determining The Inter-Se Ranking. While Submitting OffEr, It Shall Be The Responsibility Of The Bidder To Ensure That They Quote Correct Gst Rate And Hsn Number. [E] It Shall Be The Responsibility Of The Bidders To Quote Correct Hsn Number And Corresponding Gst Rate. The Purchaser Shall Not Be Responsible For Any Misclassiï¬Cation Of Hsn Number Or Incorrect Gst Rate, If Quoted By The Bidder. [F] Wherever, The Successful Bidder Invoices The Goods At Gst Rate Or Hsn Number Which Is DiffErent From That Incorporated In The Purchase Order, Payment Shall Be Made As Per Gst Rate Which Is Lower Of The Gst Rate Incorporated In The Purchase Order Or Billed. [G] Vendor Is Informed That She/He Would Be Required To Adjust Her/His Basic Price To The Extent Required By Higher Tax Bill As Per Invoice To Match The All Inclusive Price As Mentioned In The Purchase Order. [H] Any Amendment To Gst Rate Or Hsn Number In The Contract Shall Be As Per The Contractual Conditions And Statutory Amendments In The Quoted Gst Rate And Hsn Number, Under Svc. 6 Please Refer Para 15.0 Of Part - B Of Sr Normal Applicable To Yes Yes Not Allowed Tender Conditions Attached With This All Bidders Tender Document For Details Regarding Benefits Of Mse As Per Public Procurement Policy. 7 For Public Procurement (Preference To Normal Applicable To Yes Yes Not Allowed Make In India) Policy, Please Refer Para All Bidders 16.0 Of Part- B Of Sr Tender Conditions Attached To This Tender Document. Page 7 Of 15 Run Date/Time: 27/05/2025 11:07:29Stores/Southern Rly Tender Document Tender No 16255008 Closing Date/Time 30/06/2025 14:30 8 Bidder Shall Accept The Following Normal Applicable To Yes Yes Allowed Declaration [Land Border Condition] By All Bidders (Mandatory) Quoting Yes Against Conf. Allowed Or Complied Column For Compliance Of Oï¬Ƒce Memorandum Of Department Of Expenditure, Ministry Of Finance Om No. F.No.6/18/2019-Ppd Dated 23.07.2020. If Such Certiï¬Cate Given By A Bidder Whose Bid Is Accepted Is Found To Be False, This Would Be A Ground For Immediate Termination And Further Legal Action In Accordance With Law. I/We Have Read The Clause Regarding Restrictions On Procurement From A Bidder Of A Country Which Shares A Land Border With India. I/We Certify That This Bidder Is Not From Such A Country Or , If From Such A Country, Has Been Registered With The Competent Authority. I/We Hereby Certify That This Bidder, Fulfills All Requirements In This Regard, And Is Eligible To Be Considered. (Where Applicable, Evidence Of Valid Registration By The Competent Authority Shall Be Attached.) 9 1) Bidders Are Instructed Not To Indulge In Normal Applicable To Yes Yes Not Allowed Any Anti-Competitive Practices. As Per The All Bidders Provisions Of Competition Act,2002, Railways Can Make A Reference To The Competition Commission Of India For Making An Enquiry In Case Of Suspected Anti Competitive Behavior By The Bidders. 2) Collusive Bidding, Bid Rotation, Bid Suppression, Complementary Bidding, Market Allocation And Sub-Contracting Arrangements Fall Under The Purview Of Bid Rigging Which Would Cause Appreciable Adverse EffEct On Competition. 3) Competition Commission Of India Can Impose Heavy Penalties Such As: Penalty Upto 10% Of The Average Turnover For The Last Three Preceding ϬNancial Years Upon Each Of Such Enterprises Which Are Parties To Bid-Rigging And Can Even Order The Parties To Cease And Desist. 10 A) For : Destination. By Road. Normal Applicable To Yes Yes Not Allowed Accordingly, The ϬRms Are Advised To All Bidders Quote On For Destination Basis By Road And Offers With Deviations Are Liable To Be Ignored. B) Door Delivery Shall Be Made To The Consignees Along With Delivery Challan Postal Address Of The Consignee Is: Electric Loco Shed, Arakkonam, Southern Railway Chennai: 631001. Tamilnadu. Southern Railway Gst No. 33Aaagm0289c1zq. Page 8 Of 15 Run Date/Time: 27/05/2025 11:07:29Stores/Southern Rly Tender Document Tender No 16255008 Closing Date/Time 30/06/2025 14:30 11 Failure Consequences: In Case The ϬRm Normal Applicable To Yes Yes Not Allowed Fails To Execute The Contract Within The All Bidders Original Delivery Period, The Purchaser Will Be Entitled To Impose Liquidated Damages For Extension Of Delivery Period. For Any Reason, If The Supplier Fails To Supply Goods And/Or Service As Per The Conditions Of Contract, As Amended From Time To Time, Purchaser Shall Have The Right To Levy Damages From The Supplier For Failing To Comply With The Contractual Conditions, Not By The Way Of Penalty, An Amount Equal To Security Deposit Of The Defaulted Order Amount. These Damages Shall Be Treated As Recoveries Outstanding Against The Vendor And Dealt With Accordingly. 12 Tenderers To Acknowledge Having Read Normal Applicable To Yes Yes Not Allowed And Also Accept The Irs Conditions Of All Bidders Contract, Sr Tender Conditions, Special And Other Conditions Speciï¬Ed In This Tender Document/Attached To This Tender Document. Page 9 Of 15 Run Date/Time: 27/05/2025 11:07:29Stores/Southern Rly Tender Document Tender No 16255008 Closing Date/Time 30/06/2025 14:30 13 Security Deposit Shall Be Taken From All Normal Applicable To Yes Yes Not Allowed Vendors For Contract Value Above Rs.25 All Bidders Lakhs. Security Deposit Is 5% Of Total Value Of Contract Subject To Max Rs. 50 Lakhs For Contract Value Above 25 Lakhs And Up To Rs.50 Crore. Subject To The Applicable Exemptions. Security Deposit From Successful Tenderers Should Be Received In Purchase Oï¬Ƒce Within 21 Days From The Date Of Communication Of Acceptance With Respect To The Purchaser. There Shall Be No Exemption From Submission Of Security Deposit For Any Tender Or By Any Tenderer Except Following: A) The Store Contract Cases Of Value Upto Rs.25 (Twenty Five) Lakh, B) Other Railways And Government Departments In Terms Of Railway Boards Letter No. 2004/Rs(G)/779/11 Dated 24.07.2007 C) Indian Ordinance Factories In Terms Of Railway Boards Letter No.92/Rss(G)/363/1 Dated 08.04.1993 D) Psus Owned By Ministry Of Railways And Psus For The Group Of Items That Are Manufactured By Them In Terms Of Railway Boards Letter No.2003/Rs(G)/779/5 Dated 10.09.2004 E) In Tenders Issued Against Pac, Oem In Whose Favour Pac Has Been Issued Shall Be Exempted From Submitting Sd. Kvic And Acash Shall Be Exempted From Sd For Items Supplied By Them. F) Vendors Registered With Railways For The Trade Group Of The Item Tendered Shall Be Exempted From Sd For Orders Valued Up To Their Monetary Limit Of Registration. G) Vendors Appearing On The Approved Vendor Lists Of Rdso/Pus Core Subject To Approval Status Being Valid On The Date Of Tender Closing H) Vendors Registered With Railway For Supply Of Medicine, Medical Equipments And Consumables Shall Be Exempted From Submission Of Sd For These Items. (Please Refer Para 10.0 Of Part A Of Sr Tender Conditions Enclosed To This Tender Document For Further Details On This Clause). Page 10 Of 15 Run Date/Time: 27/05/2025 11:07:29Stores/Southern Rly Tender Document Tender No 16255008 Closing Date/Time 30/06/2025 14:30 14 (A) Free Delivery To Consignee. Supply Of Normal Applicable To Yes Yes Not Allowed Machine Shall Be Made As Per The All Bidders Milestone Chart Given In Sl .No.7 (Delivery Schedule Chart) Of Technical Speciï¬Cation Enclosed. (B) Bill Payment: After Successful Completion Of Purchase Order, ϬRm Has To Submit The Bill On-Line Through Ireps Portal Only For Payment. In This Regard, The Following Documents Have To Be Uploaded Based On The Crn (R-Note) Issued By Railway (A) Invoice, Gst Declaration( I.E.Self Declaration Regarding Aggregate Annual Turnover In A ϬNancial Year: Less (Or) More Than 50 Crores / Less(Or) More Than 100 Crores/Less (Or) More Than 500 Crores. If More Than 500 Crores, E-Invoice Is Required To Be Uploaded.), Rnote, Neft Mandatory. (B) Warranty/Guarantee Certiï¬Cate, Rites Certiï¬Cate, Test Report, Dealership Certiï¬Cate (Or) Proof Of Purchase From Authorized Dealer, Calibration Certiï¬Cate, Commissioning Report Whichever Is Applicable. 15 Packing Instructions: Use Re-Usable Steel Normal Applicable To Yes Yes Not Allowed Cage (Or) Wooden Box (Or) Gunny Bags All Bidders (Jute Bags) (Or) Carton Box (Or) Polythene Bags>50 Micron Only And Use Railway Parcel Transportation. Please Refer Para 1400 Of Section I Of Bid Document Part I. 16 Please Enter The Percentage Of Local Normal Applicable To No Yes Allowed Content In The Material Being OffEred. All Bidders (Optional) Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. The Deï¬Nition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. General Instructions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Railway Is Not Bound To Accept The Lowest Normal Applicable To No No Not Allowed Or Any Tender Or To Assign Any Reason For All Bidders Doing So And Railway Reserves The Right To Accept/Cancel Any Tender In Respect Of The Whole Or Any Portion Of The Items Specified In The Schedule Annexed (Or Tender Schedule) And The Contractor Shall Be Required To Supply The Same At The Rate Quoted. 2 1. For Any Queries Against This Tender, Normal Applicable To No No Not Allowed Please Contact Dycmm/Ic/Sr At All Bidders 9003060762. 2. Any Technical Clariï¬Cation Regarding Drawing/Speciï¬Cation Can Be Obtained From The Oï¬Ƒce Of The Pcme/Sr/Mas. Dy.Cme/Planning/Mas Mobile No. 9003060403 And Mail Id [email protected]. Drawing (S) / Speciï¬Cation (S) Can Also Be Obtained From The Above Oï¬Ƒce After Payment Requisite Cost. Page 11 Of 15 Run Date/Time: 27/05/2025 11:07:29Stores/Southern Rly Tender Document Tender No 16255008 Closing Date/Time 30/06/2025 14:30 3 Vendors May Please Note That Giving Normal Applicable To No No Not Allowed Intimation Regarding The Tender In Open All Bidders Tender Cases Or Giving Limited Tender Enquiry Does Not Guarantee The Suitability Of OffEr For Placement Of Purchase Order. Railway Reserve The Right To Place Purchase Order Subject To Fulï¬Lment Of Technical/Commercial Eligibility Conditions/Tender Conditions. 4 All Other Terms & Conditions As Per Irs Normal Applicable To No No Not Allowed Condition And Gcc All Bidders Other Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 A) Inspection By Tpi (Third Party Normal Applicable To No No Not Allowed Inspection Agency). Firm To Indicate All Bidders Complete Works Address Where Inspection Will Be Conducted. The Tenderer Shall Refer Annexure 13 Of Sr Tender Conditions For Further Details Regarding Tpi Clause. Please Note That OffErs With Inspection/Visual Inspection By Tpi Against Test Certiï¬Cate/Guarantee Certiï¬Cate /Work Test Certiï¬Cate Is Liable To Be Ignored. For Further Details Regarding Tpi Clause, The Tenderer Shall Refer Annexure 13 Of Sr Tender Conditions Attached To This Tender Document. Alternatively, Tenderers May Please Refer The Attachment Tpi Conditions Enclosed To This Tender Document For Ready Reference Of Bidders Regarding Tpi Clause. B) Bidder Shall Indicate Place Of Inspection For Pre-Dispatch Inspection Duly Enclosing The Documentary Evidence. Note:- Any Request For Change In Place Of Inspection Shall Only Be Entertained With Documentary Evidence. 2 No. Of Stages Of Inspection: 3; Description Normal Applicable To No No Not Allowed Of Stage-1 Inspection: Raw Material All Bidders Inspection As Per Tender Schedule (As 100% Of Po Qty.), Description Of Stage-2 Inspection: Manufacturing And Fabrication Inspection As Per Tender Schedule (As 100% Of Po Qty.), Description Of Stage-3 Inspection: Final Product Inspection At Firms Premises As Per Tender Schedule (As 100% Of Po Qty.), However, Final Inspection By Consignee At Consignees Premises As Per Clause 9 Of Bid Document Part Ii. 3 Marking : Manufacturer To Mark Their Normal Applicable To Yes Yes Not Allowed Name And Month Of Manufacture As Per All Bidders Drawing, Wherever Indicated, Or At A Location Where It May Not Get Obliterated In Service On The Item Being Supplied By Them Against The Purchase Order. Supplies Received Without This Are Liable To Be Rejected By Consignee. 4 I/We Agree To Supply The Tendered Stores Normal Applicable To Yes Yes Not Allowed At The Rates Quoted By Me/Us In All Bidders Accordance With The Irs Conditions Of Contract, Sr Tender Conditions, Special And Other Conditions Speciï¬Ed In This Tender Document/ Attached With This Tender Document. Page 12 Of 15 Run Date/Time: 27/05/2025 11:07:29Stores/Southern Rly Tender Document Tender No 16255008 Closing Date/Time 30/06/2025 14:30 5 Machine Should Have Warranty Of 24 Normal Applicable To Yes Yes Not Allowed Months From Date Of Successful All Bidders Commissioning. 6 No Developmental Order Will Be Placed For Normal Applicable To Yes Yes Not Allowed The Tendered Item. All Bidders 7 Post Warranty Camc Will Be Concluded By Normal Applicable To Yes Yes Not Allowed End-User Consignee At Their End After All Bidders Warranty Period, If Required. 8 Sd Bank Guarantee Is To Be In Favour Of Normal Applicable To Yes Yes Not Allowed Sr.Dfm/Mas. Format For Bank Guarantee All Bidders Is Available In Uploaded Document Conditions For Electronic Tenders . Contract Will Be Executed By President Of India Acting Through Principal Chief Materials Manager. Signature, Name And Address Of Two Witnesses Is Mandatory. 9 In Case Of Any Contradiction Between The Normal Applicable To Yes Yes Not Allowed Conditions Specified In The Main All Bidders Tender Document/Nit/Electronic Sor & Appended Annexures, The Condition Of Main Tender Document/Nit/Electronic Sor Will Supersede The Condition Specified In The Annexure. Special Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Insurance Charges Should Be Quoted In Normal Applicable To No No Not Allowed Other Charges Column Against The All Bidders Particular Items. No Separate Line Has Been Provided For Insurance Charges. 2 Either Along With The Third Party Normal Applicable To No No Not Allowed Inspection Or Separately, The Complete All Bidders Crane Assembly And All Its Accessories Such As Chains, Lifting Tackles As Mentioned In Schedule I Of Section V Should Be Inspected By A Competent Person Certiï¬Ed By The Director Of Industrial Safety And Health Of The Manufacturer S State. The Certiï¬Cates For The Entire Crane Assembly And The Accessories As Mentioned Above As Issued By The Competent Person In The Appropriate Format Should Be Sent To The Consignee Along With The Crane. The Validity Of Such Certiï¬Cates Should Not Have Expired At The Time Of Supply. These Certiï¬Cates Should Be Accompanied By The Credentials Of The Competent Person Also. The Validity Of His Or Her Certiï¬Cation Should Be Current On The Date Of Issue Of Certiï¬Cates By Him Or Her. Only The ϬRst Time Inspection And Certiï¬Cates Are To Be Arranged By The Supplier. Subsequent Inspections And Issue Of Certiï¬Cates Will Be Arranged By The Consignee. Technical-Compliances S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading Page 13 Of 15 Run Date/Time: 27/05/2025 11:07:29Stores/Southern Rly Tender Document Tender No 16255008 Closing Date/Time 30/06/2025 14:30 1 Bidders Must Submit Their Technical Bids Normal Applicable To Yes Yes Allowed As Per Format Annexure A. Tenderers Are All Bidders (Mandatory) Required To Submit Complete Details Including Values, Write-Up, Drawings, Sketch, Brochure Etc. As Per Requirement Speciï¬Ed In Respective Clauses Mentioned Therein. In Case Of Incomplete / Sketchy Information, The Technical OffEr Being Incomplete Is Liable To Be Rejected. Tenderers Should Clearly Indicate Compliance. 2 In The Bid Documents, Normal Applicable To Yes No Not Allowed (I) Is 3177:1999(Or Latest)And Duty Class All Bidders Iv Is To Be Read As Is 3177:2020 Duty Class M8: And (Ii) Is 807:2006 Is Be Read As Is 807:2006(Amendment -1,Oct-2014& Amendment - 2 Of Nov.2020). In Case Any Of These Speciï¬Cations Is Revised Or Upgraded Then The Latest Version Shall Take Precedence. 3 All Mechanical Equipment ( Gear Normal Applicable To Yes Yes Not Allowed Shaft, Couplers, Wheels) Drawings, All Bidders Drive Manuals, Operating Instruction And Maintenance Manual, Cable Index To Be Provided At The Time Of Supply. 6. Documents Attached With Tender S.No. Document Name Document Description 1 5380219.Pdf Leadingparametersfor50_10Toneotcrane_1.Pdf 2 5380252.Pdf Eotcranespec_1_Part1.Pdf 3 5380253.Pdf Eot Crancspec1-Part2 4 5381175.Pdf Tpi Guidelines 5 5381173.Pdf Irs Conditions 6 5401870.Pdf Sr Tender Conditions 7 5380242.Pdf Eotcranespec_2_2.Pdf 7. Responsiveness S.No. Description I/We Have Carefully Gone Through The Irs Conditions Of Contract (Included And Uploaded Along With The Bid Document) Particularly Para 2500 Pertaining To Code Of Integrity, Misdemeanor And Penalties. I/We Hereby Certify That No Other Sister Concerns Or Aï¬Ƒliates (Such As Having Common Partner/Director/Promoter/Owner/Holding Company Decision Control Etc.) Have Participated In This Tender Which Can Give Rise To A ConflIct Of Interest Or Fall Under Anti-Competitive Practices. We Understand That The 1 OffErs Of All Such Sister Concerns Including Ours Are Liable To Be Rejected As Per Relevant Provisions Of Irs Terms And Conditions. I/We, Aï¬Ƒrm That We Shall Abide By The Code Of Integrity In General, With Speciï¬C Reference To ConflIct Of Interest [Para 2502 (E)], Anti Competitive Practices [Para 2502(C)] And Obligation To Proactive Disclosures [Para 2503]. I/We Understand That We Are Fully Responsible For The Above Declaration And It Shall Not Be The Railways Responsibility To Verify The Same. I/We Are Aware That We Shall Be Liable For All Consequences Of Violation Of Code Of Integrity, If Detected, At Any Stage. 2 Validity Of Offer:-120 Days, No Deviation From The Offer Validity Period Stipulated In The Tender Is Permitted. The Tenderers In Their Bid Shall Indicate The Details Of Their Gst Jurisdictional Assessing Officers (Designation, Address & Email Id). In Case Of A Contract Award, A Copy Of Purchase Order Shall Be Immediately Forwarded By Purchaser To The Gst Jurisdictional Assessing Officer Mentioned In Tenderers Bid This Tender Complies With Public Procurement Policy (Make In India) Order 2017, Dated 15/06/2017, Issued By Department Of Industrial Promotion And Policy, Ministry Of Commerce, Circulated Vide Railway Board Letter No. 2015/Rs(G)/779/5 Dated 03/08/2017 And 27/12/2017 And Amendments/ Revisions Thereof. As A Tender Inviting Authority, The Undersigned Has Ensured That The Issue Of This Tender Does Not Violate Provisions Of Gfr Regarding Procurement Through Gem. Page 14 Of 15 Run Date/Time: 27/05/2025 11:07:29Stores/Southern Rly Tender Document Tender No 16255008 Closing Date/Time 30/06/2025 14:30 Digitally Signed By Cmm/M ( Baba Tulajaram Lalge ) , Cost Of Dsl (Type And Length Of Dsl As Specified In Schedule-L) ] , Cost Of Spares As Per Schedule-Iv & Additional Spares And Items As Specified In Schedule-I. ] , Cost Of Maintenance Tools As Per Schedule-V ] , Cost Of Installation & Commissioning Of Crane And Dsl (Length Of Dsl As Specified In Schedule -L). ] At (Location) Sse/Els/Ajj, Sr Tamil Nadu 1.00 Numbers 8 6579Ser2 Essential Non Stock --- Yes Consignee Inr (Grp1) Services (Y) Cost Of Preventive Maintenance During 1St & 2Nd Year Of Warranty Period ] At (Location) Sse/Els/Ajj, Sr Tamil Nadu 1.00 Numbers 3. T And C F.O.R Description Destination Delivery Period Description Delivery /Completion Rate Of Supply For All Items Commencement : Within 4 Months Of Issue Of Contract, However, Delivery Completion : Within 6 Months Thereafter Period Shall Not Exceed No. Of Days As Mentioned In Delivery Schedule Chart Of Para 7 Of Section Iv Of Respective Bid Document Part Ii. However, The Delivery Period Indicated Being Tentative, May Vary At The Time Of Placement Of Order. Payment Terms S.No Description Payment Terms 1 1) 60% Payment: Upon Receipt Of The M&P, Duly Pre-Inspected By A Third -Party Inspection (Tpi) Agency, Receipted At The Site By The Consignee In Good Condition And Submission Of A Joint Receipt Note. 2) 20% Intermediate Payment: After Successful Installation And Commissioning And Submission Of A Joint Commissioning Note. 3) Final 20% Payment: After Commissioning Of The M&P At The Consignees End For A Minimum Period Of 30 Days, Upon Submission Of A 10% Warranty Bank Guarantee And A Proving Test Certificate Statutory Variation Clause S.No Description Page 2 Of 15 Run Date/Time: 27/05/2025 11:07:29Stores/Southern Rly , Cost Of Preventive Maintenance During 1St & 2Nd Year Of Warranty Period ] At (Location) Sse/Els/Ajj, Sr Tamil Nadu 1.00 Numbers
Contract Date: Jun 29, 2026 Contract Value : 95.30 Lakh
Government Departments No of Bidders 1
3.
Educational and Research Institute #11299551 Price Bid
Tender For Supply Of Library Books , Library Books (Refer Nit) , Industrial Safety And Human Behaviour Kaila 9788174734532 , Engineering Mechanics Vela Murali Bks456005 , Earthquake Resist Design Structural Shashikant Dugg Bks643652 , Surveying And Levelling Subramanian 9780198085423 , Practical Railway Engineering, 2Nd Ed Clifford Bonnett 9780000990136 , Geographic Information Systems Gis For Disaster Management 2Ed Brain 9781032552460 , Design Of Structural Elements Chanakya 9781138046436 , Wind Loading Of Structures 3Rd Edition John D. Holmes 9780367241803 , Structural Analysis 3/Ed Menon 9788184877342 , Concrete Pipes And Pipelines Joshi Bks426990 , Strength Of Materials Basavarajaiah 9788173714580 , Geotechnical Engineering Debashis Moitra 9788173719905 , Textbook Of Environmental Studies For Undergraduate Courses 3 Ed Bharucha 9789389211788 , Intelligent Transportation Systems Srinivasa Kumar 9788195400928 , Transportation Engineering Srinivasa Kumar 9789389211160 , Structural Analysis With Finite Elements Hartmann 9788132208945 , Strength Of Materials Vol 1 Binu Sukumar 9789388005029 , Geospatial Technology Dwivedi 9789380381480 , Heavy Metal And Metalloid Contamination Of Surface And Underground Water Gupta A. 9781032728582 , Fundamentals Of Environmental Engineering Danny D Reible 9781566700474 , Computer-Aided Highway Engineering S Goswami 9781032728483 , Fundamentals Of Hydrology Davie 9781032251936 , Highwall Mining : Applicability, Design & Safety Porathur J. L. 9781032728919 , Environmemtal Pollution Control Engineering 4Ed Rao 9788122472288 , Plane Surveying 3Ed Chandra 9788122438802 , Design Of Reinforced Cement Concrete Vol 1 Structural Elements Bhavikatti 9788122440515 , Strength Of Materials, 2/Ed Jindal 9789352861521 , Fundamentals Of Hydraulic Engineering Sy Houghtalen 9789332507593 , Geotechnical Engineering Coduto,Yeung 9789332587427 , Strenth Of Materials Jindal 9788131759097 , Dynamics Of Structures 2Nd Ed Jain 9789357059350 , Finite Element Method With Cd Eldho Desai Shah 9788131724644 , Soil Mechanics And Foundation Engineering Purushotama Rai 9788131790816 , Engineering Mechanics - Statics & Dynamics Shames Rao 9788177581232 , Dynamics Of Structures In Si Unites 5Ed Chopra 9789353945251 , Elementary Engineering Hydrology Deodhar 9788131708057 , Environmental Studies Basak 9788131721186 , Introduction To Finite Elements In Engineering 5/E Tirupathi 9781009461818 , Strength Of Materials Rao 9781108454285 , Plumbing Engineering Nikhil Anthony 9788119365128 , Fundamental Of Ground Improvement Engi Prof.Dr.R.K. Khit 9788195916948 , Surveying And Levelling : Part - 1 Kanetkar Kulkarni Bks644037 , Surveying And Levelling : Part - 2 Kanetkar Bks644038 , A Textbook Of Strength Of Materials Rajput 9789355010704 , Building Construction Bhavikatti 9789325960794 , Fundamental Of Reinforced Concrete Chandra Bks498526 , Irrigation Engineering And Hydraulic Structures Sharma Bks535826 , Surveying I Anne Mary 9788183717304 , Highway Engineering Subramanian 9788183716888 , Strength Of Materials Bansal Bks534222 , Reinforced Cement Concrete Design (Reinforeced Concrete Structures) Punima 9788131809426 , Building Construction Rangwala Bks502124 , Civil Engineering Drawing Rangwala Bks440591 , Soil Mechanics & Foundation Engineering Modi 9788189401306 , Engineering Materials Rangwala Bks385325 , Bridge Engineering Rangwala Bks554100 , Harbour Dock And Tunnel Engineering Srinivasan Bks502125 , Solid Hazardous Watse Management 2Ed Rao 9789389354621 , Textbook Of Remote Sensing And G.I.S 4Ed Reddy 9789381075975 , Reinforced Concrete Design P.B Sharma 9789391910419 , Energy Environment Ecology And Society Anil Kumar 9788178002576 , Solved Problems In Geotecnical Engineering Sharma 9789395038478 , Highway Engineering Suganthi Bks411034 , Highway And Railway Engineering Santhanam Bks638485 , Construction Materials & Tech Mathankumar Bks638450 , Prefabricated Structures Soundrarajan Bks638488 , Structural Analysis-I Santhanam Bks479564 , Green Building Design Molykutty Bks503088 , Irrigation Engineering Basak 9780074635384 , Estimating Construction Costs Peurifoy 9780071239455 , Design Of Steel Structure Duggal 9780070260689 , Concrete Technology Gambhir 9781259062551 , Engineering Mechanics Timoshenko 9781259062667 , Flow In Open Channels Subramanya 9789353166298 , Reinforced Concrete Design 4Ed Pillai 9789354601026 , Surveying Vol - Ii 5Th Edn Duggal 9789353167523 , Surveying And Levelling Basak 9789332901537 , Prestressed Concrete 6Ed Krishna Raju 9789387886209 , Fluid Mechanics White 9789355322043 , Strength Of Materials Rattan 9789385965517 , Surveying Vol - 1 Duggal 9789353167509 , Environmental Studies-3Ed Joseph 9789352605170 , Construction Planning, Equipment Peurifoy 9780070706996 , Fluid Mechanics Fundamentals And Applic Cengel 9789353166212 , Schaums Outline Of Finite Element Analysis Buchanan 9789389691375 , Wind Energy Theory And Practice 3Ed Ahmed Bks662294 , Bituminous Road Construction In India Kandhal 9789391818821 , Mechanics Of Composite Structures Vasiliev 9781138582101 , Satellite Towns In Neometropolitan Development In India Amit Chatterjee 9789811932052 , Sustainable By Design Walker 9781032973685 , Management Of Quality In Construction Ashford 9781138607163 , Disaster Managament 2/Ed Pandey 9789357461610 , Remote Sensing And Image Interpretation Thomas Lillesand 9789354642104 , Composite Structures Of Steel And Concrete 3Ed Johnson 9788126539819 , Strength Of Materials 2Nd/Ed Debabrata Nag 9788126534876 , Reasoning Ability And Quantitative Aptitude Tcy Online 9788126559008 , Green It Strategies And Applications Using Envir Intell Bhuvan Unhelkar 9781032054025 , Bioenergy For Sustainability And Security Behera 9789381891438 , Textbook Of Engineering Geology Annadurai 9789385259937 , Structural Dynamics Mukhopadhyay 9788180520907 , Matrix And Finite Element Analysis Mukhopadhyay 9788180520754 , Irrigation Engineering & Hydraulic Structures Suresh 9789383656899 , Strength Of Materials 2Ed Vendateshan 9789383656646 , Concrete Technology Job Thomas 9788131526682 , Steel Design Segui 9788131526651 , A First Course In The Finite Element Methods Logan 9789353507855 , Civil Engineering Materials Sivakugan Tuladhar 9789386650382 , Soil And Water Conservation Engineer Fangmeier 9788131524985 , Principles Of Foundation Engineering 9Th Ed Das 9789355738110 , Elements Of Civil Engineering Balasubramanya 9789387511576 , Soil Mechanics & Foundation Engineering Huat Prasad 9788131529591 , Principles Of Foundation Engineering Das 9789386650955 , Analysis Of Structures On Elastic Tsudik 9788131518953 , Strength Of Materials : Mechanics Gupta 9789355737717 , Steel Design With Mt Segui 9789386650887 , Prestressed Concrete Structures, 6Ed Dayaratnam 9788120417915 , Fundamentals Of Reinforced Cement Concrete Designs Gahlot 9789385915611 , Instrumental Methods Of Analysis Willard 9788123909431 , Tb Of Soil Mechanics And Foundation Engineering:Geo Technical Engg Murthy 9788123913629 , Civil Engineering Through Objective Type Questions 3Ed Gupta 9788123907970 , Advanced Reinforced Concrete Design 3Ed Raju 9788123929606 , Design Of Reinforced Concrete Structures 4Ed Dayaratnam 9788120414198 , Structural Dynamics Paz 9788123909783 , Modern Prestressed Concrete Libby Bks465269 , Textbok Of Solid Wastes Managemnt Khan 9788123909448 , Analysis & Design Of Substructures, 2Ed Swami Saran 9788120417007 , Building Repair And Maintance Management Gahlot 9788123912431 , Advanced Foundation Engineering Murthy 9788123915067 , Modern Construction Management 7Ed Harris 9788126572298 , Groundwater Hydrology Rushton 9788126539772 , Textbook Of Highway And Traffic Engineering Saxena 9788123924175 , Airport Engineering Saxena 9788123915500 , Construction Dewatering And Groundwater Control 3Ed Powers 9788126541669 , Quality Management Of Cement Concrete Construction (Pb) Gahlot 9788123916989 , Tb Of Water Supply And Sanitary Engineering Husain 9788120416833 , Design Of Bridges 5Ed Raju 9788120417984 , Essentials Of Bridge Engineering 6Ed Victor 9788120417175 , Building Construction Handbook Chudley 9789381269169 , Design And Construction Of Concrete Shell Roofs Ramasamy 9788123909905 , Strength Of Materials, Vol-Ii:Advanced Theory And Problems Timoshenko 9788123910772 , Construction And Project Managment 2Ed (Pb 2018) Krishnamurthy 9789386217790 , Water And Wastewater Calculations Manual 2Ed Lin 9789353162863 , Design Of Stell Structures Abu-Saba 9788123905389 , Prestressed Concrete Problems And Solutions Raju 9788123925424 , Water Resources And Irrigation Engineering Ganesaguru Bks588955 , Dam Engineering Asthana 9789381891469 , Sedimentary Rocks In The Field A Colour Guide Stow 9781874545699 , Soil Mechanics Basic Concepts & Engineering Aysen 9780415383936 , A Tb Of Fluid Mechanics And Hydraulic Machines Bansal Bks493063 , Intelligent And Sustainable Cement Production Chatterjee A.K. 9781032728445 , Total Quality Management 5Ed Besterfield 9789353066314 , Matrix Methods Of Structural Analysis Kothandaraman 9789357059190 , Hydraulics And Fluid Mechanics Hydraulic Machine Modi , Seth Bks291963 , Limit State Design Of Steel Structures Duggal 9789353164874 , Schaums Outline Of Reinforced Concrete Everard 9789389538656 , Earthquake Resistant Design Of Structures Agarwal Bks344533 , Building Materials Varghese 9788120350915 , Total Quality Management 2Ed Mukerjee 9788119364299 , Principles Of Geotechnical Engineering 10 Th Ed Das 9789355738103 , Building Materials Products Properties And Systems Gambhir 9780071077606 , Gate 2025 Civil Engineering - Guide By Gkp C L Educate 9789356817593 , Gate 2025 Mechanical Engineering Guide Gkp 9789356817746 , Engineering Design Dieter 9789355322258 , Economics And Principles Of Management Vinoth Kumar 9788194244646 , Vector Mechanics For Engineers Dynamics Beer 9789353166656 , Aviation Maintenance Management Kinnison 9780071076838 , Theory Of Machines S S Rattan 9789353166281 , Turbomachinery Dubey 9789353161156 , Engineering Mechanics 4/E Kumar 9780070681811 , Modern Compressible Flow: With Historica Anderson 9789355320070 , Programming In Matlab Patel Mittal 9789332524811 , Finite Element Analysis Moaveni 9788131760642 , Non Conventional Energy Resources Sobh Nath Singh 9789332543577 , Additive Manufacturing And 3D Printing Technology Awari Thorat 9781041049562 , Practical Guide To Vehicle Refinishin Woodstock 9781032963570 , The Internet Of Mechanical Things The Iot Framework Sami Salama Hussen 9781041038573 , Energy Storage Systems And Components Alfred Rufer 9781041049470 , Metal Cutting Theory & Practice Stephenson 9780824758882 , Classical Mechanics Problems And Solutions Carolina C Llie 9781032983608 , Product Design Baxter 9781032967882 , Thermal Measurements & Inverse Tech Orlande 9781439845554 , The Induction Machines Design Handbook Boldea Bks331229 , Modeling And Control Of Engineering Systems Clarence W. De Silva 9781420076868 , Fundametals Of Production Planning And Control Chapman 9788131717394 , Applied Thermodynamics For Engineering Technologist 5Ed Eastop 9788177582383 , Classical Mechaincs Goldstein 9788131758915 , Introduction To Robotics Saha 9789355326461 , Thermodynamics-Basc And Applied Ganesan 9789353161279 , Ethics In Engineering 5/Ed Martin 9789355325075 , Digital Marketing Chaarlas 9788119243983 , Non Conventional Energy Resources Khan 9789352601882 , Supply Chain Logistics Management Bowersox 9789353162580 , Mechanical Metallurgy Appuraj Thiyagrajan Deiter 9781307834840 , Schaums Outline Of Continuum Mechanics Mase 9789389691283 , Schaums Outline Of Statics And Mechanics Of Materials Nash 9789389691399 , Maleev & Hartmans Machine Design 6Ed Grover 9788123926322 , Mass Transfer Theory And Applications Narayanan Bks440952 , Manual Of Fire Safety Prakash 9788123919904 , Gpropulsion Systems For Space Applications Satyanarayana 9789395038553 , Mechanics Of Materials Si Version 5Ed Philpot 9789354643293 , Introduction To Robotics 3/Ed Niku 9789357461306 , Advanced Mechanics Of Materials 6Ed Boresi 9788194726395 , Design And Analysis Of Experiments Douglas & Montgomery 9788126540501 , Machine Component Design Robert C.Juvinall 9788126559732 , Callisters Materials Science And Engineering, 2Nd Ed Balasubramaniam 9788126541607 , Process Dynamics And Control 4Ed Dale Seborg 9789354248429 , Engineering Optimization Theory And Practice 5Ed Rao 9789357461238 , Principles Of Modern Manufacturing Si Version Groover 9788126573059 , Convective Heat And Mass Transfer South Asian Edi Mostafa Ghiassiaan 9781107511811 , Continuum Mechanics Jog C S 9781108437141 , Singers Engineering Mechanics Statics & Dynamics ( Si Units ) 3Ed Vijay Kumar 9788178002194 , Analytical Mechanics Fowles 9788131501115 , Thermal Sciences Potter Scott 9788131529461 , Physical Metallurgy Principles Abbaschian 9788131520697 , Additive Manufacturing Technology Hari Prasad 9789353500481 , Computational Fluid Dynamics & Heat Ghosh Dastidar 9788131533079 , Internet Mrketing With Mt Zahay 9789355734570 , Mechanical Vibrations Theory And Applications Kelly 9788131526033 , Mechanics Of Materials, Enhanced Edi Goodno--Gere 9789355737847 , Fundamentals Of Mechatronics Jouane 9788131526026 , Mechanics Of Materials Strength Of Materials Pilli/Bala 9789386668509 , Workshop Manufacturing Practices Ai Juneja 9789387994614 , The Finite Elements Methods - Its Basis & Fundamentals 7/Ed Zienkiewiez 9789351071587 , Automation And Collaborative Robotics (Dp) Mathews 9781484277102 , The Robotic Process Automation Handbook : A Guide To Implementing Ri Systems Taulli 9781484275306 , Materials Selection In Mechanical Design 5Ed Ashby 9789351073864 , Industry 4.0 : The Industrial Internet Things Gilchrist 9781484249703 , The Finite Element Method A Practical Course 2Ed Liu 9789351071594 , Elasticity-Theory, Applications & Numerics 2Ed Sadd 9789351072270 , Energy Resources And Their Utilisation R.K. Khitoliya 9789394917040 , Workshop Theory And Practice Delilah Sam 9788119365098 , New Persp. In Hybrid Vehicle Technology Samual Rodrigues 9788119365418 , Natural Gas Engineering Selvin 9788119365197 , Machine Shop Theory Samual Rodrigues 9788119205639 , Applied Mechanics Laboratory Samual Lobo 9788119365760 , Robotics: Emerging Opportunities Adrian Dsilva 9788119523702 , Advances In Hypersonic Vehicles Samual Rodrigues 9788119365500 , Machine Elements Samual Rodrigues 9788119205691 , Work And Energy Parth Chavda 9788119365234 , Design Thinking : A Comprehensive Textbook Tiwari 9789357468640 , Welding Technology Sanfras Monteiro 9788119523023 , Combustion Engineering Samual Rodrigues 9788119205943 , Fluid Machinery Noel Vincent 9788119365029 , Renewable Energy Roy 9789384007157 , Engineering Graphics Using Autocad 7/Ed {Pb} Elanchezhian C 789387938564 , Introduction To Micromachining 2Ed Jain 9788184873610 , A Systems Approach To Automotive Technology Erjavac 9788131512111 , Emotionally Intelligent Design Pavliscak 9789352138029 , Mechanics Of Solids Binu Sivakumar 9789380381671 , Mechanics Of Solids Christian Johnson 9789385983085 , Jet Engines Jaganathan 9789380381497 , Essentials Of Management, 11Ed Koontz 9789353168148 , Disaster Management Subramanian Bks481407 , Engineering Fluid Mechanics Kumar Bks613447 , A Textbook Of Fluid Mechanics Rajput Bks648302 , A Textbook Of Thermal Engineering ( Lpspe ) Khurmi Bks613483 , Materials Science And Engineering Raghavan 9788120350922 , Engineering Economics 2Nd Ed Panneerselvam Bks661039 , A Tb Of Theory Of Machine Gupta R Khurmi Bks408347 , Energy Security And Sustainability Shukla A. 9781032728926 , Mechanical Engineering Jain Bks554131 , Engineering Materials And Metallurgy Annamalai 9789386235046 , Kinematics Of Machinery Baskar Bks462932 , Thermal Engineering Swaminathan Bks638475 , Engineering Materials And Metallurgy Baskar Bks638439 , Lean Manufacuring Kalyana Chakravarthy Bks638464 , Elements Of Mechanical Engineering Singh Bks448529 , Fundamentals Of Manifacturing Engineering Singh 9789380156002 , Strength Of Machine Elements Ghorpade 9789384726003 , Observability Engineering Achieving Production Excellence Majors 9789355422996 , Research Methodology 5Ed Kothari 9789389802559 , The Automotive Body Vol 2 Morello 9788132208884 , Kinematics Of Machines Kumar 9789388005425 , Essentials Of Heat And Fluid Flow In Porous Media Narasimhan 9789382127215 , Analysis Of Composite Structures Decolon 9789380931463 , Theory Of Elasticity Chandramouli 9789380381633 , Principles Of Composite Material Mechanics 3Ed Gibson Bks380369 , Introduction To Combustion Engineering Basic And Applied Amitava Sarkar 9789357053129 , Textbook Of Finite Element Analysis Seshu Bks414440 , Engineering Thermodynamics Savithiri Bks442773 , Automobile Engineering Vol-Ii Kirpal Singh 9788180142512 , An Introduction To Mechanical Engine 4Ed Wickert Lewis 9789353507473 , Welding Engineering & Technology Parmar Bks53191 , Manufacturing Technology Vol 1-Foundry Forming Rao 9789353160500 , Manufacturing Technology Singh 9789381162385 , Dynamics Of Machines Balaguru 9789386668608 , Unconventional Machining Vivekanandhan Bks613041 , Basic Civil And Mechanical Engineering Shanmugam 9789355329547 , Engineerin Drawing 2Ed Shah / Rana 9788131710562 , Materials For Engineers And Technicians 7Ed Bolton 9781032973722 , Fuel Cell Technology Handbook Hoogers Bks333321 , Robots And Robotics Miller 9789387572966 , Non Destructive Testing And Materials Vivekanandhan Bks476859 , Engineering Mechanics Nelson 9780070146143 , Engineering Tribology 4Ed Stachowiak 9789351071679 , Materials Selection In Mechanical Design 5Ed Ashby 9789351073864 , Automobile Engineering Ayyappan Karthikeyan Bks464418 , Thermal Engineering Swaminathan Bks638475 , Automobile Engineering Babu Singh Bks587323 , A Textbook Of Production Technology Sharma Bks479783 , A Textbook Of Mechatronics Rajput Bks554009 , Automobile Engineering Jain 9780070445291 , Engineering Mechanics Statics & Dynamics Khanchani 9788180521089 , Basic Mechanical Engineering Prabhu 9788183715737 , Powder Metallurgy Ramakrisnan 9789381714485 , Additive Manufacturing Technology Hari Prasad 9789353500481 , Switching And Finite Automata Theory Jha 9780521176804 , Introduction To Mechanics 2Nd Ed Mahendra K Verma 9788173719813 , Basic And Applied Thermodynamics - A Ready Recknor Bhat 9789388005074 , Basic Refrigeration And Airconditioning 4Ed Ananthanarayanan 9781259062704 , Engineering Mechanics Applied Mecha Gupta 9789353505240 , Mechatronics Sathish Kumar Bks476759 , Automobile Engineereing Vol I Singh Bks247106 , Process Planning And Cost Estimating Selvakumar Bks480422 , Non Conventional Energy Resources Sawhney 9788120346093 , Non Conventional Energy Resources Sobh Nath Singh 9789332543577 , Introduction To Micromachining 2Ed Jain 9788184873610 , Vector Mechanics For Engineers Statics/Dynamics (Sie) Beer 9789353166625 , Fluid Mechanics &Hydraulics Rev &Updated Edn Ukarande 9789381162538 , Mechanical Measurements - Revision 6Ed Beckwith 9789353945633 , Vibration Monitoring Testing And Instrumentation C W.De Silva 9781032292137 , A Treatise On Turbomachines Gopalakrishnan Bks321517 , Construction Materials Vs Karthikeyan Bks476834 , Design Of Machine Elements Bhandari 9789390177479 , Mechanical Vibrations Bhava 9788131732489 , Design Of Transmission Systems Baskar Bks476758 , Engineering Materials And Metallurgy Baskar Bks638439 , Manufacturing Technology Vivekanandhan Bks638476 , Design Of Machine Elements Arunraja Bks638441 , Mechanical Vibrations Nag 9788126530908 , Power Plant Engineering Dhanasekar Bks505300 , Statistical Quality Control A Modern Introduction 6Ed Montgomery 9788126525065 , Additive Manufacturing Technologies Shiva Ahuj Shukla 9789357462419 , Hydraulics And Pneumatics Dixon Bks638479 , Engineering Principles Of Ground Modification Hausman 9789351341871 , Engineering Thermodynamics 6Ed Nag 9789352606429 , Refrigeration And Air Conditioning Arora 9789390385843 , Enterprise Resource Planning 4Th Edn Leon 9789353167820 , Foundations Of Material Science And Engg 6Th Edn Smith 9789355322173 , Shigleys Mechanical Engineering Design Budynas 9789390219636 , General Studies Paper - I ( 2025 ) Mhe 9789355327796 , Erp Demystified 3/Ed Leon 9789383286676 , Heat And Mass Transfer 6Ed Cengel 9789390185283 , Engineering Noise Control: Theory And Practices 4Ed Bies 9780415487078 , Rapid Prototyping And Engineering Applications Frank W.Liou 9781138569577 , Strength Of Materials Vol Ii Binu Sukumar 9789388005418 , Mechatronics A Foundation Course Clarence W.De Silva 9781138569553 , Design And Analysis Of Randomized Algorithms Hromkovic 9788132231592 , Metrology And Measurements Annamalai 9789388005463 , Fluid Mechanics And Machinery Molykutty 9789391549725 , Micro Electro Mechanical System Design Allen 9780824758240 , Micromachining Of Engineering Materials J Mcgeough 9781032419794 , Gas Turbine Combustion-3 Rd Ed Lefebvre 9781138569584 , Ergonomics Laboratory Exercises Joseph Gallwey 9781032973005 , Introduction To Biofuels Mousdale 9781439812075 , Environmental Engineering Charles Monteiro 9788119205509 , Power Plant Engineering Lijo Thomas 9788119365036 , Industrial Engineering Richard Carvalho 9788119205523 , Design & Operation Of Heat Exchanger Gerhard Rott 9788119365425 , Hydro Power Gerhard Rott 9788119205912 , Air Conditioning And Ventilation Systems Lijo Thomas 9788119365401 , Materials Science And Engineering Raghavan 9788120350922 , Automation And Collaborative Robotics (Dp) Mathews 9781484277102 , Design Management : Create, Develop And Lead Effective Design Teams Picchi 9781484283615 , Heat And Mass Transfer 2Ed Karwa 9789811926099 , Testing Of Metallic Materials 2Ed Suryanarayana 9788178001340 , Introduction To Engineering Materials 2/Ed Murray George 9781032530772 , Mechanics Of Composite Materials 2/Ed Jones R.M 9781138571075 , Reliability Evaluation Of Enginnering Systems 2Ed Billinton 9788181285522 , Workshop Practice Manual 6/Ed Reddy 9788178003078 , Finite Element Analysis 2D Lakshmi Narasai 9789389354225 , Engineering Mechanics Pb Lakshmi 9789390211609 , Engineering Mechanics 2Ed Harbola 9788131518298 , Environmental Science And Engineering Rajesh Gopinath 9789387511569 , Materials Science And Engineering Periodical Renewal Gilmore 9788131520451 , Environmental Science With Mt 16 Th Ed Miller 9789355738899 , Fluid Mechanics Munson Huebsch 9788126553433 , Engineering Mechanics: Dynamics, Si Version Meriam Bolton 9788126565375 , Engineering Mechanics Statics And Dynamcs James Meriam Kraige 9789354248566 , Engineering Fluid Mechanics Elger 9788126564491 , Engineering Mechanics Applied Mecha Gupta 9789353505240 , Machine Design Data Book Ramana 9789387593879 , Heat Transfer Alan 9789332575066 , Theory Of Machines 3Ed Bevan 9788131729656 , Introduction To Enviromental Engineering And Science Masters 9789332549760 , Heat And Mass Transfer Mayilsamy 9788131733837 , Engineering Thermodynamics 4Ed Rogers 9788131702062 , Operations Research :An Introduction-10Th Ed Hamdy Taha 9789352865277 , Engineering Mechanics - Statics & Dynamics Shames Rao 9788177581232 , Automation, Production Systems, And Computer - Integrated Manufacturing 5Th Ed Groover 9789361592959 , Introduction To Materials Science For Engineers 9E/D Shackelford 9789357059978 , Fundamentals Of Engineering Drawing Luzadder 9789332549982 , Engineering Materials Properties And Selection 9Ed Budinski Naraimhulu 9789332574045 , Thermodynamics Rajadurai Bks471287 , Environmental Science And Engineering Kaushik 9788122436471 , Engineering Optimization 4Ed Rao 9789395161800 , Cad/Cam/Cim 5Ed Radhakrishnan 9789395161855 , Finite Element Analysis With Ansys Workbench Tickoo 9789355513007 , Industrial Waste Management Mathankumar Bks480053 , Metrology And Measurements Vivekanandan Bks638442 , Finite Elements Analysis Baskar Bks534307 , Environmental And Agriculture Kavitha Bks638465 , Energy Materials Bandarenka A.S 9781032530789 , Digital Twin Ranjan Ganguli 9781032934198 , Industry 5.0 The Future Of The Industrial Economy Uthayan 9781032600130 , Quantum Computation Helmut Bez 9781032983738 , Wind Electrical Systems Bhadra, 9780195670936 , Metal Fatigue In Engineering Stephens 9788126539215 , Introduction To Industrial Internet Of Things And Industry 40 Sudip Misra 9781032146751 , Sustainable Manufacturing For Industry 4.0 Jayakrishna K. 9781032728728 , Reverse Supply Chains: Issues And Analysis Gupta S.M. 9781032729039 , Industry 5.0 The Future Of The Industrial Economy Uthayan 9781032600130 , Gas Turbine Heat Transfer Cooling Je-Chin Han, Sandip Dutta 9781439855683 , First Course In Aerial Robots And Drones (A) Bestaoui Sebbane 9781032963518 , Handbook Of Induction Heating Rudnev 9780824708481 , Fracture Mechanics (Forth Ed) T.L Anderson 9781032292120 , Fire Safety Engg Design Of Structures, 2Ed Purkiss 9788131220085 , Future Energy Improved Sustainable And Clean Opitons Letcjer 9788131220849 , Introduction To Finite Elements In Engineering 5/E Tirupathi 9781009461818 , Fundamentals Of Gas Dynamics Babu 9781910390009 , Fundamentals Of Propulsion Babu 9788180522529 , Engineering Metrology 3Rd Ed Narayana Bks396066 , Engineering Mechanics Kumaravelan Bks315205 , General Aptitude For Competitive Examinations Pattanaik Bks670722 , Dictionary Of Heat Power Engineering Ramalingam 9789386923035 , Environmental Pollution Principles Narayana Bks353570 , Production Processes Luqman 9788123918983 , Tractors And Their Power Units, Hb Lijiedahal 9788123905013 , Metal Cutting Principles Shaw 9788123901367 , Sheet Metal Press Tools Design And Making A Practical Approach Luqman 9788123925134 , Solid State Physics Wahab 9788184877786 , Practical Non - Destructive Testing, 3Ed Baldev Raj 9788173197970 , Mechanics Of Machines, 3Ed Ramamurti 9788173198922 , Handbook On Quality And Productivity Improvement Of Concrete Nayak 9788184876390 , Environmental Studies 4Ed Rajagopalan 9789354978944 , Finite Element Methods Dhanraj 9780198073901 , Fluid Dynamics Raisinghania Bks320511 , Entrepreneurship 11/Ed Hisrich 9789390113309 , Thermodynamics 9Th Ed Cengel 9789353165741 , Cad / Cam : Computer - Aided Design & Manufacturing Groover 9788177584165 , Engineering Vibration, 4/E Inman 9789332518483 , Thermodynamics 9Th Ed Cengel 9789353165741 , Schaums Outline Of Mechanical Vibration Graham Kelly 9789389538861 , Enterprise Resource Planning Singla 9789360531485 , Machine Drawing 51Ed Bhatt 9789385039560 , Heat Treatment : Principles And Techniques 3Ed Rajan 9788119364077 , Total Quality Management 2Ed Mukerjee 9788119364299 , Heat Treatment : Principles And Techniques 3Ed Rajan 9788119364077 , Operations Research Panneerselvam 9789354437892 , Design Thinking Teun Den Dekker 9781032786018 , Aeroplane Ramalingam 9788193103159 , Faqs In Control Systems Engineering Pattanaik 9789394639003 , Mass Transfer - Theory & Practice Begum/Anantharaman 9788120341692 , Total Quality Management 5Ed Besterfield 9789353066314 , Production &Operations Management 3Ed Panneerselvam Bks477079 , Manufacturing Technology Vol 2-Metal Cutting Rao 9789353160524 , Engineering Drawing Agrawal 9789353167448 , Cad / Cam : Computer - Aided Design & Manufacturing Groover 9788177584165 , Engineering Mechanics : Statics & Dynamics Kottiswaran Bks307984 , Power Plant Engineering Hegde 9789332534100 , Hydraulics And Fluid Mechanics Hydraulic Machine Modi , Seth Bks291963 , Fundamentals Of Heat And Mass Transer Kothandaraman Bks481435 , Alternative Fuels For Ic Engines Krishnasamy 9789364441995 , Mechatronics Electronic Control Systems In Mechanical And Electrical Eng Bolton 9789357052849 , Manufacturing Technology Vol 2-Metal Cutting Rao 9789353160524 , Fundamentals Of Heat And Mass Transer Kothandaraman Bks481435 , Mechatronics Electronic Control Systems In Mechanical And Electrical Eng Bolton 9789357052849 , Production &Operations Management 3Ed Panneerselvam Bks477079 , Engineering Drawing Agrawal 9789353167448 , Mass Transfer - Theory & Practice Begum/Anantharaman 9788120341692 , Industrial Robotics Control Frigeni 9781484294154 , Gate 2025 Production And Industrial Eng Gkp 9789356818170 , Engineering Vibration, 4/E Inman 9789332518483 , Fundamentals Of Engg Heat And Mass Transfer-5Ed Sachdeva 9789386070968 , Internet Of Nanothings And Wireless Body Area Networks Fadi 9781032599144 , Modern Machining Processes Pandey 9789386761835 , Materials Science For Mechanical Engineering Palanisamy 9789386923059 , Materials Science For Mechanical Engineering Palanisamy 9789386923059 , Textbook Of Fluid Dynamics Chorlton 9788123908816 , Engineering Mechanics : Statics & Dynamics Kottiswaran Bks307984 , Robotics Rajmohan Bks480419 , Hmt Data Book Kothandaraman 9788812243594 , Design Data (Data Book) Psg Bks58578 , Digital Signal Processing 2Ed Paulo Diniz 9781108406703 , 8086 Microprocessor And Applications 3Ed Kani 9789354661327 , Wireless Telecommunication System & Network Mullett 9788131520123 , Operational Amplifiers & Linear Integrated Circuits Lal Kishore 9788177585667 , Mobile Computing Principles Bfar 9780521696234 , Microprocessors & Programmed Logic 2Ed Short 9788131709160 , Design With Pic Microcontroller Peatman 9788177585513 , Digital Systems Design With Access Code Nagoor Kani 9789354667688 , Introduction To Biomems Folch 9781032568225 , Introduction To Biomedical Equipment Technology 4Ed Carr 9788177588835 , Antennas & Wave Propagation Raju 9788131701843 , Raspberry Pi For Dummies Cook 9789357460422 , Digital Signal Processors : Architectures --Op Kuo 9788131717936 , Principles Of Electromagnetics, 6Ed Sadiku 9780199461851 , Advanced Digital Design With The Verilog Michael.D.Ciletti 9789332584464 , Neural Networks Kumar 9781259006166 , Embedded System 2Nd Ed Peckol 9789357463966 , Microprocessor And Peripherals Chowdhury Bks405737 , Networks & Systems Roy Choudhury 9789389802535 , Microcontroller Theory And Application With The Pic Rafiquzzaman 9788126548354 , Digital Signal Processing For Anna University Kani 9789354661006 , Digital Signal Processing 3Ed Kani 9789354661167 , Analog And Pulse Circuits Lakshmaiah D 9789389354201 , Electronic Devices And Circuits Orient 9789386235305 , Quantum Chemistry 7 Ed Levine 9789332558533 , Engineering Circuit Analysis 9/Ed Hayt 9789390185139 , Gate 2025 Electronics And Communication Eng.Guide Gkp 9789356819306 , Chip Design For Submicron Vlsi : Cmos Layout And Simulation Uyemura 9788131501955 , Microelectronics Neamen 9789354601637 , Neural Networks And Learning Machines Haykin 9789332570313 , Electronic Circuits : Fundamentals And Applications 5Ed Tooley 9781032726687 , A Course In Digital Signal Processing Pucca Bundh Porat 9788126534913 , Signals And System Apte 9781316615393 , Digital Design 6Ed Mano 9789353062019 , Principles Of Signal Processing And Liner System Lathi 9780198062288 , Fiber Optic Communications 5Ed Palais 9788131717912 , Circuits And Networks Sudhakar 9789339219604 , Introduction To Communication Systems Madhow 9781316608241 , Analog Communication Rao 9780070704800 , Arduino Based Embedded Systems Singh 9781032964058 , Next Generation Wireless Lans 2Nd Ed Perahia 9781107414617 , Arm Microprocessor System Tahir 9781138387539 , Digital Communication Mutagi Bks478677 , Advanced Microprocessors & Peripherals Bhurchandi 9781259006135 , Vlsi Design Chitra 9788183716598 , Television And Video Engineering Salai Thillai 9788183712194 , The Design Of Cmos Radio Frequency Integrated Circuits Lee 9780521613897 , Network Security : Private Communication In A Public World Charlie Kaufman 9788196874339 , Sensors And Transducers Patranabis 9788120321984 , Neuro Fuzzy And Soft Computing Jang Sun Mizutani 9789332549883 , Network Analysis Channa Venkatesh 9788131533215 , Circuits Carlson 9788131505861 , Op Amps And Linear Integrated Circuits : Concepts And Applications Fiore 9788131512340 , Mobile Computing Principles Bfar 9780521696234 , Instrumental Methods Of Analysis Willard 9788123909431 , Vlsi Circuits And Embedded Systems Hasan Babu 9781032906003 , Computer Organization And Embedded System-6 Th Ed Hamacher 9789339218317 , Network Analysis And Synthesis, 2Ed Singh 9789353166724 , Handbook Of Biomedical Instrumentations Khandpur 9789355328021 , Security And Privacy In Internet Of Things Lots Hu Fei 9781032707150 , Television & Video Engineering Veeralakshmi 9789380156699 , Power Quality Sankaran 9781138569249 , Introduction To Microcontroller Programming For Power Electronic Control Applications Rossi 9781032972183 , Communications System Laboratory Preetham Kumar 9781138603288 , Digital Signal Processing And Its Applications Senthil Kumar 9788195268726 , Multimedia Enabled Sensors In Iot Fadi 9781032599205 , Novel Wearable Antennas For Communication And Medical System Albert Sabban 9781041049579 , Internet Of Things Using Single Board Computers : Principles Of Iot And Python Programming Kanagachidam Baresan 9781484299258 , Handbook Of Optical Communication Networks Ilyas 9781498798037 , Communications System Laboratory Preetham Kumar 9781138603288 , Digital Watermarking And Steganography 2Nd Edition Shih 9781032972121 , Propagation Handbook For Wireless Communication System Design Crane 9780849308208 , The Internet Of Things In The Cloud Honbo Zhou 9781498770354 , Arduino Based Embedded Systems Singh 9781032964058 , 5G Mobile Communications Concepts And Technologies Saad Asif 9781032663159 , Electronic Devices 10Ed Robert Floyd 9789354493935 , Semiconductor Physics And Devices, 3Ed Sze 9789354243226 , Digital Fundamentals 11Ed Floyd 9789332584600 , Electronic Devices And Circuits--11 Ed Boylestad Nashelsky 9789332542600 , The 8051 Microcontrollers & Embedded Systems 2Ed Mazidi 9788131710265 , A System C Primer 2Ed Bhasker 9788178001418 , Household Electricity And Appliances P.B Bhagava 9789390211265 , Image Processing Analysis And Mach Sonka 9789386858146 , Verilog Hdl 2Ed +Cd Palnitkar 9788177589184 , Modern Semiconductor Devices For Integration Hu 9788131730249 , Analog Integrated Circuit Design Isv 2Nd Ed Chan Carusone 9788126543939 , Textbook Of Digital Electronics Vasudevan 9789381714539 , Microwave Engineering 4Ed Das 9789390113347 , Analysis Of Microcontrollers For The Students Kothari 9789381714294 , Digital Signal Processing : For C.S.I.T Palani 9789380618388 , Fundamentals Of Digital Images Processing Jain 9789332551916 , Signals And Systems Sreenivasa Reddy 9789389354041 , Satellite Communications Pratt 9789354243035 , Analog Signals And Systems Kudeki 9788131787984 , Embedded Systems Handbook 2Ed System Design And Verification Zurawski Bks331222 , Vlsi Design And Eda Tools 2Nd Ed Sarkar 9788183714976 , Vlsi Design Das 9780198094869 , 8085 Microprocessor Pramod Borole 9789382127581 , Fundamentals Of Communication Systems Proakis 9788131705735 , Short Range Wireless Communication 3Ed Bensky 9789351073994 , Introduction To Fiber Optics Ghatak Ajoy 9781316644010 , The Definitive Guide To Arm Cortex M3 And Cortex M4 Processors Yiu 9789351071754 , Rf Circuit Design Ludwig 9788131762189 , Electric Circuits For Be/Betch 2Ed Kani 9789354663925 , Control Systems Nagoor Kani 9789389239010 , Digital Logic Circuits Nagoor Kani 9789354669989 , Microwave And Rf Design Steer 9789380381305 , Electrical Measurement And Measuring Instruments Rajput Bks543993 , Digital Signal Processing 3Ed Kani 9789354661167 , A Handson Course In Sensors Using The Arduino And Raspberry Pi Ziemann Volker 9781032791470 , Signal And Systems Simplified 2Ed Nagoor Kani 9789354661013 , Basic Electrical And Electronics Engineering 2/Ed Bhattacharya 9789332586505 , Ad Hoc Wireless Networks : Architectures & Protocols Murthy 9788131706886 , Ad Hoc And Wilreless Sensor Network Athawale 9789356066137 , Digital Circuits Design Kothari 9789332543539 , Solid State Electronic Devices Streetman 9789332555082 , Wireless Communication Goldsmith 9780521704168 , Probability And Stochastic Processes 3Ed Yates 9789354243455 , Signals, Systems And Inference Oppenheim 9789356064676 , Electromagnetic Field And Waves Salivahanan 9788119896677 , Analog Design For Cmos Vlsi Systems Maloberti 9788181284341 , Vlsi Design Michael 9780849318764 , Cognitive Sensors And Iot Fadi 9781032599236 , Digital Design & Computer Organization Farhat 9780849311918 , Digital Intergrated Circuits Evegni 9780849330575 , Introduction To Iot With Machine Learning And Image Processing Using Raspberry Pi Ambaji Kulkarni 9781032966885 , Basic Electrical And Electronics Engineering Murugan 9789384726072 , Adaptive Antenna Arrays Chandran 9788181289322 , Networks Lines & Fields 2Ed Ryder 9789332559516 , Data Compression : The Complete Reference Salomon 9788184898002 , Electric Circuits Bell Bks321194 , Digital Signal Processing Oppenheim 9789332550339 , Iot Standards With Blockchain : Enterprise Methodology For Internet Of Things Upadrista 9781484284278 , An In Depth Guide To Mobile Device Forensics Chuck Easttom 9781032785905 , Digital Signal Processing Oppenheim 9789332550339 , Digital Modulation & Coding Wilson 9788131721438 , Fundamentals Of Mobile Computing 2Ed Pattnaik Bks534717 , Introduction To Iot With Machine Learning And Image Processing Using Raspberry Pi Ambaji Kulkarni 9781032966885 , Biomedical Instrumentations And Measurements Cromwell 9789332556911 , Artificial Neural Networks For Engineers And Scientists Chakraverty S. 9781032729121 , Digital Communication Bhattacharya 9780070591172 , Signals And Systems 2/Ed Oppenheim 9789332550230 , Fundamentals Of Modern Vlsi Devices Yuan Taur 9781316649794 , Digital Systems:Principles&Design(Anna) Rajkamal 9789332535916 , Principles Of Cognitive Radio Vincent 9781107439900 , Digital Signal Processing 4Ed Proakis 9788131710005 , Op Amps And Linear Integrated Circuits Gayakwad 9789353949037 , Microwave And Radar Engineering Rao 9788131799444 , Introduction To Pspice Using Orcad For Circuits And Electronics Rashid 9789332555174 , Basic Electronics Saha 9781316632932 , Linear Integrated Circuits Salivahanan 9789353163808 , Principles Of Electronic Communication Orient 9789386235107 , Optoelectronic Devices And Optical Fiber Communication Chakrabarti 9789354667947 , Introduction To Vlsi Design Flow Sneh Saurabh 9781009200813 , Antennas And Wave Propagation Kraus 9789352606184 , Network Analysis Revised 3Ed Van Valkenburg/ Rathode 9789353433123 , Communication Systems : Analog And Digital, 3Rd Singh 9781259004605 , Internet Of Things The : How Smart Tvs Sm Miller 9789332552456 , Microwave Devices & Circuits 3Ed Liao 9788177583533 , Fundamentals Of Mobile Computing 2Ed Pattnaik Bks534717 , 5G Mobile And Wireless Communication Technology Pauline Cullen 9781009590921 , The Intel Microprocessors : 8086/8088,80186/80188,80286,80386,80486,Pentium, Pentium Pro Processor, Pentium Ii - 8Ed Brey 9788131726228 , Circuits Analysis Theory And Practic Robbins 9788131519028 , Medical Instrumentation 5Ed : Application And Design : An Indian Adaptation Webster 9789354249150 , Microwave Engineering, An Indian Adaptation Theory And Techniques Pozar 9789388991087 , Wireless Communications 2Ed Molisch 9789354248795 , Controll System Eng. 8/Ed Norman 9789357463980 , Signals, Systems, And Transforms, 4/E Phillips 9789332518490 , Antenna Theory And Applications 4Ed Balanis 9789354248474 , Gate 2025 Electronics And Communication Eng.Guide Gkp 9789356819306 , Introduction To Analog And Digital Communication 2Ed Haykin 9789354644337 , Digital Image Processing Gonzalez 9789353062989 , Power Electronics (An Indian Adaption) Ned Mohan 9789354640278 , Dorfs Introduction To Electric Circuits Wiley India Edition Richard 9788126573493 , Electronic Devices 10Ed Robert Floyd 9789354493935 , Communication Systems 5Ed Haykin 9789354640896 , Modern Control Engineering Ogata 9789332550162 , Electric Circuits With Mt Kang 9789386650344 , The Intel Microprocessors : 8086/8088,80186/80188,80286,80386,80486,Pentium, Pentium Pro Processor, Pentium Ii - 8Ed Brey 9788131726228 , Modern Digital Electronics-5Th Edtion Jain 9789355321770 , Analog And Digital Electronics Roth 9789353502355 , Introduction To Communication Systems Madhow 9781316608241 , Voip Handbook Application Technologies Ahson 9781420070200 , Embedded Systems Handbook 2Ed Network Embedded System Zurawski Bks331227 , Matlab: An Introduction With Applications 6Ed Amos Gilat 9789357462174 , Fiber Optic Communication Systems 5Ed Agrawal 9789357461245 , Crc Handbook Of Modern Telecommunications 2Ed Morreale Bks331221 , Mathematical Aspects Of Signal Processing Sircar 9781107175174 , Rf And Microwave Semiconductior Device Handbook Golio 9780849315626 , Electronic Systems Maintenance Handbook, Second Edi Whitaker Bks322864 , The 8051 Microcontroller Ayala 9788131502006 , Digital Systems Design Using Vhdl W/ Roth 9788131518304 , Fundamentals Of Engineering Electromagnetics Cheng 9789332535138 , Basic Electronics-2Ed Kothari 9789352606467 , Power Electronics Essentials & Applications Umanand 9788126519453 , An In Depth Guide To Mobile Device Forensics Chuck Easttom 9781032785905 , Automotive Embedded Systems Handbook Navet Bks335190 , Wavelet Analysis With Applications To Image Process Prasad 9780849331695 , Primer On Wavelets And Their Scintific Applications Walker 9781032963617 , Face Detectin And Recognition: Theory And Practice Datta A.K. 9781032728964 , Fiber Optics & Optoelectronics Khare 9780195669305 , Mobile Cellular Telecomm 2E Lee 9780070635999 , Cmos Vlsi Design : A Circuits And Systems Perspective, 3Ed Weste 9788131762653 , Antennas Blake 9789380381268 , Mobile Communications, 2Ed Schiller 9788131724262 , Introduction To Wireless Systems Black 9788131726389 , Ad Hoc And Wilreless Sensor Network Athawale 9789356066137 , Linear Integrated Circuits Sathishkumar Bks476847 , Linear Integrated Circuits Dhanasekar Bks638493 , Embedded And Real Time Systems Ramprabu Bks476848 , Transmission Lines And Rf Systems Shanmugaraja Sivakumar Bks490771 , Transmission And Distribution Gayathri Bks476751 , Wireless Communication Santhosh Krishna Bks638491 , Digital System Design Edwindhas Bks638462 , Power Quality & Distributed Generation Jayaprakash 9788184876987 , Digital Signal Processing Antoniou 9780070636330 , Power System Engineering 3 Ed Kothari 9789353165116 , Digital Integrated Circuit 2/Ed Rabeay 9789332573925 , Principles Of Electronic Materials Kasap 9789390113866 , Digital Logic Circuits With Vhdl And Verilog Programs Nagoor Kani 9789354669606 , Principles Of Electronic Materials Kasap 9789390113866 , Wireless Communications : Principles Rappaport 9789356066212 , Communication Networks Fundamentals Leon 9780070595019 , Interoperability In Iot For Smart Systems Roy M. 9781032728100 , Basic Elec & Linear Circuits Bhargava 9781259006463 , Brain Computer Interface Eeg Signal Processing Panigrahi 9781032851181 , Learning Basics And Electronic Science Through Mcqs Priya 9789394639249 , Fundamentals Of Logic Design Roth 9789360535650 , Engineering Circuit Analysis 10E/D Hayt 9789364441094 , Programmable Logic Controllers 6Th Ed Petruzella 9789355325860 , Modern Wireless Communication Haykin 9788131704431 , Signals And Systems 5Ed Ramesh Babu Bks505218 , Digital Signal Processing Ramesh Babu Bks503977 , Digital Image Processing 2Ed Sridhar Bks643706 , Digital Logic Circuits With Vhdl And Verilog Programs Nagoor Kani 9789354669606 , Wireless Communications : Principles Rappaport 9789356066212 , Digital Integrated Circuit 2/Ed Rabeay 9789332573925 , Brain Computer Interface Eeg Signal Processing Panigrahi 9781032851181 , Internet Of Nanothings And Wireless Body Area Networks Fadi 9781032599144 , Phyiscs For Electronics & Information Science Palanisamy 9789386923134 , Vlsi Design Sathyah Bks665018 , Basic Elec & Linear Circuits Bhargava 9781259006463 , Communication Networks Fundamentals Leon 9780070595019 , Linear Integrated Circuits Salivahanan 9789353160487 , Wireless Communications : Principles Rappaport 9789356066212 , Linear Integrated Circuits Salivahanan 9789353160487 , Digital Logic & Computer Design Mano 9789332542525 , Digital Electronics Bignell 9788131520710 , Design Of Analog Cmos Integrated Circuit-2Ed Razavi 9789387067844 , Fundamentals Of Logic Design Roth 9789360535650 , Engineering Circuit Analysis 10E/D Hayt 9789364441094 , Digital Electronics Bignell 9788131520710 , Design Of Analog Cmos Integrated Circuit-2Ed Razavi 9789387067844 , Applied Machine Learning Gopal 9789354601590 , Essentials Of Digital Signal Process Using Matlab Ingle/Proakis 9788131517727 , Arm System On Chip Architecture Furber 9789332555570 , Smart Grid In Iot Enabled Spaces Fadi Ai Turjman 9781032598543 , Power Plant Engineering Nag 9789354600050 , Mathematical Analysis A Straightforward Binmore 9781107526235 , Algebra 2Nd Edition Michael Artin 9789353432751 , Discrete Mathematics Dhami 9780199452798 , Statistics And Numerical Methods 10Ed Vijayakumari 9789356062733 , Algebra, 3Ed Sahai 9788173198250 , Algebraic Topology M J Greenberg , J R Harper 9780367475604 , Algebra, 4Ed Sahai 9788184876208 , Concept Of Modern Algebra Pandey 9788184877069 , Friendly Introduction To Number Theory Silverman 9789353433079 , Elementary Differential Equations 8Ed Richard 9789332571617 , Introduction To Graph Theory West 9789332549654 , Linear Algebra Ubaidullah 9789391549893 , Higher Algebra Barnard 9789385923326 , Sequences And Series Arumugam 9789388005128 , Modern Analysis Arumugam 9789388005111 , Intorduction Topology And Modern Analysis Simmons 9789387465916 , Higher Algebra Hall Knight 9788174731043 , Analytical Geometry Veerarajan 9789388005142 , Transforms And Partial Diffrential Equations 3Rd Ed Muthucumaraswamy 9789391549473 , Multilevel Analysis: Techniques And Applications 3/E Hox 9781032938035 , Thomas Calculus 15Ed Hass 9788119896608 , Calculus Vil I 2Ed ( An Indian Adaptation) Apostol 9789354642630 , Calculus 10Ed Saturmino Salas Einar Hille Ga 9789390421961 , Introduction To Linear Regresion Analysis, 6Ed Montgomery 9789357461283 , Matrices Advanced Calculus & Complex Stewart 9789360534509 , Operations Research Mote 9788126556380 , Topology 2Ed James Munkres 9789353432775 , Linear Algebra 5Ed Friedberg 9789390168132 , Multivariate Calculus Joshi Bks498996 , Mathematical Analysis 6Ed Malik Bks413195 , Stochastic Processes 5Ed Medhi 9789389802245 , Human Resource Management Aswathappa 9789355323675 , The Elements Of Complex Analysis 3Ed Choudhary 9789388818780 , Probability And Statistics For Engineering Devore 9789353506247 , Operations Research Panneerselvam 9789354437892 , The Elements Of Complex Analysis 3Ed Choudhary 9789388818780 , Optics 8Ed Ghatak 9789355328595 , Outline Of Beginning Physics Schaum 9789389538984 , Outline Of Astronomy Schaum 9789389538939 , Introductory Nuclear Physics 3/Ed Krane 9789354640834 , Physics Vol 2 5Ed David Halliday Resnick 9789354640438 , Physics For Scientists And Engineers Serway 9789355739223 , Non Conventional Energy Source Math 9789388005081 , Nuclear Physics Theory And Experiments 3Ed Roy 9788122449884 , Gravitation : Foundations And Frontiers (South Asian Edition) Padmanabhan 9780521178761 , Electricity And Magnetism Murugeshan 9789352837342 , Introductory Nuclear Physics Wong 9788126546060 , Modern Physics Murugeshan Bks367126 , Introduction To Electrodynamics South Asia Ed - 4/Ed David J. Griffiths 9781108822909 , Theoretical Astrophysics Vol 2 Padmanabhan 9781107400603 , Heat Thermodynamics And Statistical Physics Lal Subramanian Bks460942 , Classical Dynamic Of Particles Thornton 9788131518472 , Materials For Engineers And Technicians 7Ed Bolton 9781032973722 , Statistical Mechanics 2Ed (An Indian Adaption) Kerson Huang 9789354247736 , Atomic And Molecular Spectroscopy Rita Kakkar 9781108413206 , Laser Fundamentals Silfvast 9780521138475 , Engineering Chemistry 2E : Fundamentals And Applications Shikha Agarwal 9781108724449 , Organic Name Reations Sanjay Bari 9789389354737 , Basics Of Environmental Science Khosla 9788184874013 , Environmental Chemistry Singhu 9788122427318 , Biomaterials Principles And Applications Joon Park 9781032934167 , Organic Reaction Mechanisms Ahluwalia Bks366263 , Organic Synthesis Concepts And Methods 3Ed Pb 2014 Jurgen Hinri 9788126547227 , Engineering Chemistry Palanna 9789352605774 , Engineering Chemistry 2Nd Ed Wiley 9788126543205 , A Textbook Of Engineering Chemistry Dara Bks561640 , Engineering Chemistry Vairam & Kalyani 9788126543342 , Chemical Applications Of Group Theory Albert Cotton 9788194726364 , Environmental Science And Engineering Yuganath 9788183717014 , Environmental Science Isv 8Th/Ed Botkin, Killer 9788126534142 , Chemical Reaction Engineering 3Ed (An Indian Adaptation) Octave Levenspiel 9789354244605 , Outline Of Thermodynamics Schaum 9789389538540 , Textbook Of Chemical Engineering Thermodynamics Narayanan 9788120347472 , Communication Skills, 3Ed Sanjay Kumar 9789354978555 , English For Science & Technology-I Chellammal 9781009224796 , English For Science & Technology-Ii Francis 9781009251181 , Effective Technical Communication Rizvi 9789352605781 , Research Methodology Vinod 9789352863518 , Placement Interviews Skills For Success Anandamurugan 9780070700956 , Prowess Orient 9789354421242 , Research Methodology Panneerselvam 9788120349469 , Academic Writing A Handbook For Students Stephen Bailey 9781138615533 , Design Thinking In Technical Communication Jason C K Tham 9781041004356 , Principles Of Scientific And Technical Mohapatra 9789355327482 , Critical Thinking Idea Innovation And Creativity Richard H Mccuen 9781041000846 , Literature For Language Skills 2Ed Mahanand 9789388005470 , Academic Writing P.B Ajay Semalty 9789390211739 , Teaching English Through Folktales Mahanand 9789391549077 , An Introduction To Literary Studies Mario Klarer 9781032785974 , Heritage Of Tamils Muthuramalingam 9789391549718 , A Short History Of English Literature Saintsbury 9788174733054 , The English Language Wrenn 9788174733368 , An Introduction To The Study Of English Litetrature Hudson 9788174731197 , Rabindranath Tagores Ideational Challenges Bidyut Chakrabarty 9789356400122 , English Literature Long Bks476291 , Test Of Reasoning 7Th Edn Thorpe 9789389811513 , Science And Technology 8Ed Agarahri Ravi 9789355326324 , Excel Reasoning Arun Sharma 9789355329455 , Aptipedia Aptitude Encyclopedia 2 Ed Wiley 9788126569502 , Excel Quantitative Apititude Arun Sharma 9789355327970 , Verbal Ability And Reasoning For Competitive Examinations Anand Lalit Singh 9788126554294 , Intermediate Engligh Grammer With Answers, 2Ed Murphy 9788185618517 , Design Thinking Teun Den Dekker 9781032786018 , Spotting Errors Lakshminarayanan Bks670723
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
4.
Public Administrative Department #11290947 Technical Bid
Tender for Cartage Of Malva, Silt, Sludge Kankar And Other Disposable Organic Material Etc. All Complete With Labour T&P Including Cartage Of 8 Km. (Chapter No.3 Si.No.8) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (1 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (2 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (3 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Earth Work In Filling In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 8Km. Form The Foundation Trenches Including Royalty@ 9.00 Per Cum. (Chapter No.4 Pwd.Sch.-253(A)+ Cptr No. 3 1 To 8 Km.) , Earth Work In Excavation In Foundation In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Earth Work In Excavation In Foundation In Ordinary Soil Mixed With Moorum Shingle Kankar Requiring The Use Of Special Tools And Plants Such A Pick Axes Subbals Etc. Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Extra For Earth Work In Embankment Mechanically Compacted To 98% Proctor Density Ln Ordinary Soil, Excavation To Be Done Form Of Regular Pits Not Exceeding 0.5Mtr In Depth And Work In Embankment To Be In 20Cm Layer Including Ramming And Dressing Pulverization Surfacing Including Supply Of Labour, T&P, Roller And Water Sprinkle , Back Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth: Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50M And Lift Upto 1.5 M Incl. Cost Of All Labor Complete As Per Specifications , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 1.50M To 3M. , Supply & Fixing 3.5Kg And Or As Specified By The Manufacture, Harderner In Trexim Concrete Per Sqm. , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 3.00M To 4.50M. , Cleaning Jungles Including Uprooting Of Trunk Vegetation Grass, Bushes, Wood Trees And Sapling Of Girth Upto 30Cm Measured At A Height Of 1 Meter Above Ground Level And Removal Of Rubbish Upto A Distance Of 50 Meters Out Side The Periphery Of Area Cleared. , Removal Of Silt For Nala/Nali In Liquid Mud Or Faul Position With Special T&P Including Lead 30M And Lift Up To 3.00M Etc. All Complete. (As Per Attached Sanctioned Rate Analysis) , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 4.50M To 6.00M. , Earth Work In Cutting Or In Embankment In Ordinary Soil Excavation To Be In The Form Of A Regular Pits Not Exceeding 0.50M In Depth And Earth Work In Embankment To Be In 20Cm Layers Including Ramming And Dressing The Surface To Required Lavels And Slops And Also Including 1.5 M Lift And 30 M Lead. The Earth In Form Of Cutting (B) To Be Used As Spoil Banks Within 50M Distance As Directed By The Engineer-In-Charge Etc. All Complete. (4-Chapter Si.No.3) , Sand Filling In Plinth Including Supply Of Necessary Quality Of Local Sand From A Distance Not Exceeding 8 Kms From The Site Of Work And Including Watering Dressing Etc.Required For Proper Completion Of Work (Chapter No.4 Si.No.6 ) , Providing And Laying Cement Concrete In 1:5:10 (1 Cement :5 Fine Sand 10 Stone Ballast 40 Mm Gauges) And Curing Complete, Including Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.1) , Providing And Laying Cement Concrete In 1:4:8 (1 Cement:4 Coarse Sand :8 Graded Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors (5-Chapter Sr.No.2) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand :6 Gladed Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.3) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand:6 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors. (5-Chapter Sr.No.5) , Providing And Laying Cement Concrete In 1:2:4 (1 Cement: 2 Coarse Sand :4 Graded Stone Aggregate 40 Mm Noffrinal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors..(5-Chapter Sr.No.6 Si.No..4.1.3) , Providing And Laying Cement Concrete In 1:1.5:3 (1Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors. (5-Chapter Sr.No.7) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement -All Work Up To Plinth Level: 1:2:4 (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete , Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Up To Plinth Leuel:1:2:4 In Raft Foundation (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Trp To Plinth Level : 1:1.5:3 (1 Cement:1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) Ch-S Si No- 5,1.2 , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete,Slab Including The Cost Of Centering, Shutterang, Finishing And Excluding Reinforcement - Above Plinth Level Upto Fifth Floor Lable : 1:1.5:3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Upto Plinth Level , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Above Plinth Level Upto Fifth (V) Floor Lable , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Balconies, Shelves, Chajjas, Bands, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Including The Cost Of Centering, Shuttering, Finishing Exlcuding Reinforcement, With 1:1.5:3 In Heavier Beam (1 Cement: 1.5 Coarse Sand(Zone-Lll) : 3 Graded Stone). , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Work Up To Plinth Level (5-Chapter S.I. No.-16) , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Works Above Plinth Level Upto Floor V Level (5-Chapter S.I. No.-16) , Class-150 (Non Modular) Brick Work In 1:6 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work.. ( Chapter No. 06 Sr.No. 1) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Foundation And Plinth Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapter No. 06 Sr.No. 2) , Class-150 (Non Modular) Brick Work In 1 :4 Cement And Fine Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Only 80Mm Thick Wall). (Chapter No. 06 Sr.No.3) , Class-150 (Non Modula0 Brick Work In L:3 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Chapter No. 06 Sr.No.4) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. (Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand Mortor In Super Structure Above Plinth Level Upto Floor Five Level For Wall Thickness More Than 12Cm. Including Supply Of All Material, Labour And Tools And Plants Etc. All Complete. {Chapter No.6 Si.No.2+6} , Add Extra To Ltem No. 1 To 4 Above For Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 12Cm And Less. (Chapte No. 06 S.I. No. 2+4) , Add Extra To Ltem No. 1 To 4 Above But In Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 8Cm And Below. (Chapte No. 06 S.I. No. 2+4) , Providing And Laying Damp-Proof Course 40 Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.1} , Providing And Laying Damp-Proof Course 25 Mm Thick With Cement Concrete 1:2.4 (1 Cement : 2 Coarse Sand :4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.2} , Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Vg-10 Of Approved Quality Using 1.7K9 Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With Piece Of Cloth Lightly Soaked In Kerosene Oil.. {Chapter No.07 Si.No.3} , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (A) 35Mm Thick. (Chapter No.9 Si.No.1-9.21.1) , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (2) 30Mm Thick. (Chapter No.9 Si.No.1-9.21.2) , Providing & Fixing 1.00 Mm Thick Decorative High Pressure Laminated Sheet Of Plain/Wood Grain In Gloss/Matt/Suede Finish With High Density Protective Surface Layer And Reverse Side Of Adhesive Bonding Uality Conforming To Is : 2046 Type S, Including Cost Of Aadhesive Of Approved Quality. , Providing And Fixing Factory Made Panel Pvc Door Shutter Consisting Of Frame Made Out Of M.S. Tubes Of 19 Gauge Thickness And Size Of 19 Mm X 19 Mm For Styless And 15X15 Mm For Top & Bottom Rails. M.S. Frame Shall Have A Coat Of Steel Primers Of Approved Make And Manufacture. M.S. Frame Covered With 5 Mm Thick Heat Moulded Pvc C Channel Of Size 30 Mm Thickness, 70 Mm Width Out Of Which 50 Mm Shal Be Flat And 20 Mm Shalll Be Tapered In 45 Degree Angle On Both Sides Forming Styless And 5 Mm Thick, 95 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered In 45 Degree On The Inner Side To Form Top And Bottom Rail And 115 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered On Both Sides To Form Lock Rail And Lock Rails Shall Be Top, Bottom And Lock Rails Shall Be Provided Both Sides Of The Panel. 10 Mm (5 Mm X 2) Thick, 20 Mm Wide Cross Pvc Sheet Be Provided As Gap Insert For Top Rail & Bottom Rail. Paneling Of 5 Mm Thick Both Side Pvc Sheet To Be Fitted In The M.S. Frame Welded/Sealed To The Styles & Rails With 7 Mm (5 Mm + 2 Mm) Thick X 15 Mm Wide Pvc Sheet Beading On Inner Side, And Joined Together With Solvent Cement Adhesive. An Additional 5 Mm Thick Pvc Strip Of 20 Mm Width Is To Be Stuck On The Interrior Side Of The C Channel Using Pvc Solvent Adhesive Etc. Complete As Per Direction Of Engineer-In-Charge, Manufacturers Specification & Drawing.30 Mm Thick Pre Laminated Pvc Door Shutters , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Ls: 1868, Minimum Anodic Coating Of Grade Ac 15) , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item): With Float Glass Panes Of 4.0 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 5.5 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 8.0 Mm Thickness , Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is : 6315 , Having Brand Logo Embossed On The Body/ Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors ,Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor . Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Entineer-In-Charge. With Stainless Steel Cover Plate Minimum 1.25 Mm Thickness. , Providing And Tixing Factory Made Upvc White Colour Casement/ Casement Cum Frxed Glazed Door Comprising Of Upvc Multi-L Chambered Frame. Sash And Mullion (Where Ever Required) Extrlcled Profiles Dl,Ly Reinforced With 1.60 T 0 2 Mm Thick I Galvalized Mild Steel Section Made From Roll Forming Process Of Iequrred Length {Shape & Size According To Upvc Profile), I Ldvc Extruded Glazing Beads Of Appropriate Dimension. Epdi\/L Gasket. Znc Alloy (White Powder Coated) 3D Hrnges And One Handle On Each Side Of Panels Along With Zinc Plated Mild Steel Rnulti Point Locking Having Transmission Gear, Cylinder With Keeps And One Sicle Key, G.L Fasteners 100 X I Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Mullion (If Required) Shall Be Also Fusion Weldecl Including Drilling Of Holes For Fixing Hardwares And Drainage Of Water Etc. Afier Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Of Approvecl Quality, All Complete As Per Approved Drawing & Cllrection Of Engineer-In-Charge. (Single I Double Glass Panes And Sllicon Sealent Shall Be Paid Separately) Note: For Upvc Frame, Sash And Mullion Extruded Profiles Minus 5% Tolerance In Dlrnension I.E. In Depth & Width Of Profile Shall Be Acceptable Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. Casement Door With 3D Hinges Made Of (Big Series) Frame 67 X 64 Rm & Sasn 67 X 1 10 Mm Both Having Wall Thickness Of 2.3 I 0.2 ^Rr Ancl Single Glazing Bead / Double Glazing Bead Of Lappopiate D.Mersion. (Area Of Door Upto L2 00 Sqm). , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Structural Steel Work In Single Section, Fixed With Or Withoul Connecting Plate, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required Heavy Size Such As Trusses Built , Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2 Mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6 Mm, With 40Mm Dia Steel Pulleys, Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Apptying A Priming Coat Of Approved Steel Primer.(Chapter No.10 Si.No.4-10.3) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pjpe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\4.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover (Upto 10.00 Sqm).(Chapter No.10 Si.No.4-10.5) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pipe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\Il.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X,1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover Extra For Providing Mechanical Device Chain And Crank Operation For Operating Rolling Shutters. Exceeding 10.00 Sqm And Upto 16.80 Sqm/Above In The Area , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc, Complete. Hot Finished Welded Type Tubes , Supply And Fixing Stainless Steel (Grade 304) Ralling Made Of Hollow Tubes, Channels, Plates Etc. Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Steel Nuts And Bolts Complete. I/C Fixing The Ralling With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts Fasteners Etc.). (Chapter No.10 Si. No. 14 New) , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Galvanised M.S. Wire Gauze With 0.63 Mm Dia Wire And 1 .4 Mm Aperture On Both Sides , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Stainless Steel (Grade 304) Wire Gauze Of 0.5 Mm Dia Wire And 1.4 Mm Aperture On Both Sides , Painting Top Of Roofs With Bitumen Of Approved Quality @ 17Kg Per 10 Sqm Impregasted With A Cost Of Coarse Sand At 60 Codm Per 10 Sgm, Including Cleaning The Slab Surface With Keroseme Oil Complete : With Residual Type Petroleum Bitmen Of Grade Vg-10 , Providing And Laying Integral Cement Based Water Proofing Itreatment Including Preparation Of Surface As Required For Itreatment Of Roofs, Balconies, Terraces Etc Consisting Of Lfollowing Operations: (A) Applying A Slurry Coat Of Neat Cement Lusing 2.75 Kg/Sqm Of Cement Admixed With Water Proofing Lcompound Conforming To Ls. 2645 And Approved By I E Ng Ineer-In-Charge Over The Reinforced Cement Concrete Slab Including Adjoining Walls Lupto 300 Mm Height Including Cleaning The Surface Before Llreatment. B) Laying Brick Bats With Mortar Using Broken Bricks/Brick Bats 125 Mm To 115 Mm Size With 50% Of Cement Mortar 1:5 (1 L Cement : 5 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Over 20 Mm Thick Layer Of Cement Mortar Of Mix 1:5 (1 Cement :5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Ofjunctions Of Walls And Slabs. (C) After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Using 2.75 Kg/ Sqm Of Cement Admixed With Water Proofing Compound Conforming To Lb : 2645 And Approved By Engineer-In-Charge (D) Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix L:4 (1 Cement :4 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Includlng Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finjshing The Surface With Lrowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep (E) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test.All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge :Wth Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65Mm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 1.00 Mm Thick With Zinc Coating Not Less Than 275 Gm/Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 80 Mm Thick With Zinc Coating Not Less Than 275 Gm/ Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 0.63 Mm Thick With Zinc Coating Not Less Than 275 Gm/ M , Providing And Laying Six Courses Water Proofing Teatment With Bitumen Felt Over, Roofs Consisting Of First, Third And Llfth Course Of Blown Bitumen 85/25 Or 9O/15 Conforming To Ls : 702 Applied Hot @ 1.45, L.2O And 1.45 Kg Per Square Metre Of Area Respitively, Second And Fourth Courses Of Roofing Felt Lype 3 Grade I Conforming To Ls : 1322 (Hessian Based Self Flnished ;Itumen Felt) , Sixth And Final Course Of Stone Grit 6 Mm And Down Size Or Pea Sized Gravel Spread At 6 Cubic Decimeter Per Sqm Iniluding Preparation Of Surface But Excluding Grading, Complete. , 10 Cm Thick (Average) Mud Phaska Of Damped Brick Earth On Roofs Laid To Slope Consolidated And Plastered With 25 Mm Thick Mud Mortar Mixed With Bhusa @ 35 Kg Per Cum Of Earth And Gobri Leaping With Mix 1:1 (1 Clay: 1 Cow Dung) And Covered With Flat Tile Bricks, Grouted With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement And Finished Neat: With Common Burnt Clay F.P.S.(Non Modular) Brick Tile Of Class Designation 10 , Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineerin-Charge) 0 50 Mm (+ 0.05 %) Total Coated Hickness With Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Icrons Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge, The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roollng Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete :Ridges Plain (500 - 600Mm) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Ls: 12823 Grade Ltype Ll, In Anelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer-In-Charge.Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side , Providing And Fixing 12 Mm Thick Panelling Or Panelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows (Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured). Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40 Mm Thick. I\4Arine Plywood Conforming To Ls: 710 , Providing And Fixing Tiled False Ceiling Of Specilled Materials Of Size 595X595 Mm In Lrue Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanlzed @ 120 Grams/ Sqtn, Both Side Inclusive) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick (Minimum) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet, 1200 Mm Long Spaced Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel Lo Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting/Making, Opening For Services Like Diffusers, Grills, Iight Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gl Slotted Cleats Of Size 27 X 37 X 25 X1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gl Adjustable Rods With Galvanised Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T- Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. Gl Metal Ceiling Lay In Plain Tegular Edge Global White Color Tiles Of Size 595X595 Mm, And 0.5 Mm Thick With 8 Mm Drop; Made Of G Lsheet Having Galvanizing Of 100 Gms/Sqm (Both Sides Inclusive) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns (Minimum), Including Factory Painted After Bending , Providing And Fixing False Ceiling At All Heights With Integral Densified Calcium Silicate Reinforced With Fibre And Natural Filler False Ceiling Tiles Of Size 595X595mm Of Approved Texture, Design And Patterns Having Nrc (Noise Reduction Coefficient) Of 0.50 (Minimum) As Per Ls 8225:1987, Light Reflectance Of 85%(Minimum). Non Combustible As Per Bs:476 (Part-4), Fire Performance As Per Bsi476 (Part 6 &7), Humidity Resistance Of 100%, Thermal Conductivity 0.043 W/M K As Per Astm 518:1991,In True Horizontal Level Suspended On Inter- Locking Metal T-Grid Of Hot Dipped Galvanised Iron Section Of 0.33Mm Thick (Galvanized @ 120 Grams Per Sqm Including Both Sides) Comprising Of Main T Runners Of Size 24X38 Mm Of Length 3000 Mm, Cross - T Of Size 24X32 Mm Of Length 1200 Mm And Secondary Intermediate Cross-T Of Size 24X32 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600 Mm, Suspended From Ceiling Using Galvanised Mild Steel Items (Galvanizing @ 80 Grams Per Sqm) I.E. 50 Mm Long, I Mm Outer Diameter M-6 Dash Fasteners, 6 Mm Dia Fully Threaded Hanger Rod Upto1000 Mm Length And L-Shape Level Adjuster Of Size 85X25x25x2 Mm. Galvanised Iron Perimeter Wall Angle Of Size 24X24x0.40 Mm Ol Length 3000 Mm To Be Fixed On Periphery Wall / Partition With The Help Of Plastic Rawl Plugs At 460 Mm Center To Center And 40 Mm Long Dry Wall S.S Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-Incharge. With 15 Mm Thick Tegular Edged Light Weight Calcium Silicate False Ceiling Tiles. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:6 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of 1:4 Cement & Fine Sand (Not Less Than In 1.25 Fm) Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:3 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:4 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 20 Mm Cement Plaster 1:3 (L Cement:3 Coarse Sand) Linished With A Floating Coat Of Neat Cement. , 20Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding Bomm. Ln Girth And Finished Even And Smooth , 6Mm Thick Celling Plaster 1:3 (1 Cement :3 Fine Sand) Cement & Fine Sand In F.M Not Less Than 1.25, 1:3 Including Chipping Of Reinforced Cement Concrete Surface Before Celing Plaster. The Cost Of Including At Material, Labor T&P And Scafolding Etc Complete. (Chapter No.13 Si.No.13) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Morlar1:4 (1 Cement: 4 Coarse Sand) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement: 4 Coarse Sand). Including 50Mm Thick Base With Concrete 1:4Rb Complete As Per E/L , Marble Tiles Stone Slabs 18 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With : Marble White Dhungriquality , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With: White Alebeta White Stone , Kota Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1: 4 (1 Cement: 4 Coarse Sand) : 25 Mm Thick , Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , 40 Mm Thick Fine Dressed Stone Flooring Over 20 Mm (Average) Thick Base Of Cement Moftar 1:5 (L Cement: 5 Coarse Sand)With Joints Finished Flush.Red Sand Stone , Prividing & Laying Ceramic Non Skid Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming Tq Ls : 15622 Of Approved Make In Colours Such As White, Lvory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Ioints With White Cement And Matching Pigment Etc., Complete. , Providing & Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming To Ls : 15622 (Thickness To Be Specified By The Manufacturer )Of Approved Make In Atl Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-Incharge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Morta|L:3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 33Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Providing And Laying Vitrified Tiles 500X500mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providing And Laying Vitrified Tiles 600X600mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providlng And Laying Polished Granite Jet Black Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge.{Chapter No.14 Si.No.27} , Stone Work (Machine Cut Edges) For Wall Llning Etc. (Veneer Work) Upto10 Metre Height, Backing Filled With A Grout Of Avercge 12 Mm Thick Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Polnting In White Cement Mortar 1:2 (1 White Cement R 2 Stone Dust) Wlth An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Plns Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Flne Dressed With Rough Backing. 30 Mm Thick , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. Including Curing The Cost Of All Material, Labour, T&P Etc. Complete. (Chapter No.15 Si.No.1) , Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Ofwork. , Finishing Walls With Water Proofing Cement Paint Of Required Shade : New Work (Two Or More Coats Applied @ 3.84 Kg/10 Sqm) Supply Of All Labour Material And T&P Requlred For Proper Completion Of Work. , Finishing Walls With Textured Exterior Paint Of Required Shade New Work (Two Or More Coats Applied @ 328 Ll Lo Sqm) Over And Including Priming Coat Of Exterior Primer Applied @ 2.20K9/10 Sqm Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade ; New Work (Two Or More Coat Applied @ 1.67 Llth) Sqm Over And Including Priming Coat Ofexterior Primer Applied @ 2 20 Kg/10 Sqm) Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/L0 Sqm Over An Under Coat Of Primer Applled @ O.B0 Ltr/10 Sqm Of Approved Brand And Manufacture. Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacturb Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Paint Of The Two Coat Over Primer Coat Wood Surface And Etc. All Complete.(15-Chapter Si.No.8+10+11) , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Upto 10 Cm In Width , Applying Priming Coat: With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood) Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Of Work , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade Two Or More Coats On New Work Includlng Cost Of All Materials, Labour T&P Etc. Required For Proper Completion Of Work Wood And Steel , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..One Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..Two Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Sudace Smooth Including Necessary Repairs To Scratches Etc. Complete. , Distempering With Lst Quality Acrylic Distember (Ready Mix) Having Voc Content Less Than 50 Grams/ Litre Of Approved Brand And Manufacture To Give An Even Shade:Old Work (One Or More Coats) , White Washing Wth Lime On Undecorated Wall Surface (One Coat) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , White Washing Wth Lime On Undecorated Wall Surface (Three Or More Coats) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , Colour Washing Such As Green, Blue And Other Coloures Or Buff To Give An Even Shade New Work Colour Washing (Two Coats) With A Base Coat Of White Washing With Limes Including Cost Of All T&P Other Complete Work. , Removing White Or Colour Wash By Scrapping And Sand Papering And Pteparing The Surface Smooth Including Necessary Repairs To Scratches Etc Complete , Demolishing Cement Concrete Manually Including Disposal Of Materialwithin 50 Metres Lead , Dismantling Reinforced Cement Concrete Or Reinforced Brick Work Including Stacking Of Materials As Directed By E/Ic With In A Distance Of 60 Meters (200 Feet). (17-Chapter Pwd. No.694) , Demolishing R.B. Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-Incharqe. , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge In Cement Mortar. (17-Chapter Si.No.6) , Demolishing Stone Rubble Masonry Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Eng;Neer-In-Charge : Ln Lime Mortar , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead Of Area 3 Sq. Metres And Below , Dismantling Steel Work In Single Sections Including Dismembering And Stacking Within 50 Metres Lead In: R.S. Joists , Dismantling Stone Slab Flooring Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead. (17-Chapter Si.No.16) , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Wlthin 50 Metres Lead. , Dismantling Of Old Interlocking Tiles Pavement Including Staking Of Serviceable Material And Disposal Of Unserviceable Material Within Lead Of 50M As Per Direction Of Engineer In Charge. (Ns) , Random Rubble Masonry 1:6 (1 Cement: 6 Coarse Sand), With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size).Upto Plinth Level With , Random Rubble Masonry 1:6 (1 Cement : 6 Coarse Sand), With Hard Stone In Superstructure Above Plinth Level And Upto Floor Five Level, Including Leveling Up With Cement Concrete 1:6:12 (L Cement:6 Coarse Sand:12 Graded Stone Aggregaie 20 Mm Nominal Size) At Window Sills, Ceiling Level And The Like , 30 Mm Red Sand Stone Sun-Shade (Chisel-Dressed) Supported On Red Sand Stone Brackets, Fixed In Walls With Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Finishing Complete. , Providing And Fixing Red Sand Stone Jali 40 Mm Thick Throughout In Cement Mortar 1R3 (1 Cement : 3 Coarse Sand), Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment, Matching The Stone Shade, Jali Slab Without Any Chamfers Etc , Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) Including Pointing In White Cement Mortar 1:2 (1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Fine Dressed With Rough Backing. 30 Mm Thick (Chapter No.18 Si.No.7) , Supply And Fixing 500 Liter Pvc. Sintex Water Tank Etc. All Complete. (19-Chapter Sr.No.2(C)) , Laying Brick Soling Layer On Prepared Sub-Grade With Brick On End Edging According To Lines, Graded And Cross-Section Shown On The Drawing Filling Joints With Sand And Earth, Spreading 25 Mm Thick Layer Of Earth Over Brick Soling, Watering And Rolliing The Same With Three Wheel Road Roller 80-100 Kn As Per Technical Specification Clause 412 , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Constuction Of Un-Reinforced, Plain Cement Concrete Avement Thickness As Per Disign, Over A Prepared Sub Base With 43 Grade Cement Or Any Other Type As Per Clause 1501.2.2 M-30 (Grade), Coarse And Fine Aggregate Conforming To Is 383, Maximum Size Of Coarse Aggregate Not Exeeding 25Mm, Mixed In A Concrete Mixer Of Not Less Than 0.2 Cum Acapacity And Apporopriate Weigh Batcher Using Approved Mix Design, Laid In Approved Fixed Side Formwork (Steel Channel, Laying And Fixing Of 125 Micron Thick Polythene Film Wedges, Steel Plates Including Levelling The Formwork As Per Drawing), Spreading The Concrete With Shovels, Rakes, Compacted Using Needle, Screed And Plate Vibrators And Finished In Continous Aperation Including Provision Of Contraction, Expansion, Construction And Constructionl Joints, Applying Debonding Strips, Primer, Sealant, Dowel Bars, Near Approaches To Bridge/Culvert And Construction Joints, Admixtures As Approved, Curing Of Concrete Slabs For 14 Days, Curing Comound (Where Apecified) And Water Finishing To Lines And Grade As Per Drawing And Technical And Technical Sepcification Clause 1501. (For Agra). (Chapter No.20 Si.No.12) , Construction Of Un-Reinforced, Plain Cement Concrete Pavement Over A Prepared Sub Base With Approve Grade Cement @ 400 Kg Per Cum, Coarse And Fine Aggregate Conforming To Ls 383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed In A Batching And Mixing Plant As Per Approved Mix Design, Transported To Site, Laid With A Fixed Form Or Slip Form Paver, Spread, Compacted And Finished In A Continuous Operation Including Provision Of Contraction, Expansion, Construction And Longitudinal Joints, Joint Filler, Separation Membrane, Sealant Prim Er, Joint Sealant, Debonding Strip, Admixtures As Approved, Curing Compound, Finishing To Lines And Grades As Per Drawing For Agra , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work.80 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Coloured) , Re-Laying Of I Shaped Precast Interlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50Kg) Including 25Mm Thick Loacal Sand Base Levelling And Ressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Comlete Work. Including Vat (Chapter No.20 Si.No.19 New Item) , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe. (Lnternal Work - Exposed On Wall) 32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 40Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 50Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 15 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 20 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 25 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 32 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 40 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 62.50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 75 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 100 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 150 Mm Nonrinal Dia Pipes , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 15 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 20 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 25 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 32 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 40 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 50 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 15 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 20 Mm Dia Nominal Bore , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 60X60x75 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 90X90x100 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 120X120x100 Cm Lnside , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Ls : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Lsl Marked White Solid Plastic Seat And Lid , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required One Urinal Basin With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Two Urinal Basins With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Three Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Four Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require: (White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C. P. Brass Pillar Taps) {Chapter No.24 Si.No.5A} , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630X450 Mm With A Single 15 Mm C.P. Brass Pillar Tap , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 550X400 Mm With A Pajr Of 15 Mm C.P. Brass Pillar Taps , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Flat Back Wash Basin Size 550X400 Mm With Single 15 Mm C.P. Brass Pillartap , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.6A) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350 Mm With White Pvc Automatic Flushing Cistern, With Fittings, Standard Size C.P. Brass Flush Pi Pe, Spreaders With Unions And Clamps (All In C.P. Brass) With Waste Fitting As Per Ls:2556, C.L. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fittlngs And Cutting And Making Good The Walls And Floors Wherever Requlred:Range Of Two Half Stall Urinals With 5 Litre Pvc. Automatic Flushing Cistern , Constructing Brick Masonary Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 455X610mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (A) Inside Dimensions 455X610mm And 45Cm Deep For Single Pipe Line : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.6A) , Constructing Brick Massonry Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 600X850mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (C) Inside Dimensions 600X850mm And 45Cm Deep For Pipe Line With Three Or More Inlets : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.8C) , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) Hindi Letters , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) English Letters , Reinforced Cement Concrete M15 Grade Boundary Pillars/ Wheel Guard Of Standard Design As Per Irc:25-1967, Fixed In Position Including Finishing And Lettering But Excluding Painting , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.2 Metre High , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.8 Metre High , Deduction Of Cost Brick/Bats. (Chapter No.1 Sr.No.2(C)) , Deduction Cost Of Material Old Workable Bricks Etc. All Complete. , Road Delinator Delinealor Supply & Fixing Of M S Delineator Made Of L\Lild Steel With Pllre Polyester Powder Coating With The Minimum Thickness Of Powder Coating Of Not Less Than 40 Micron For Prolectlon Against Corlosion The Surface Should Be Concealed So That There Sholrld Not Be Any Exposed Surface Wilhout Powder Coating. Alternatively, These Metal Guide Poles Can Be Concealed With Thermoplastic Body. The Posts Shall Have Lan Ellipsoidal Or Circular Design Wilh The Height Of The Pole Shall Be 800 To 900 Mm Above The Ground With About 200 To 300 Mm Base Which Can Be Anchored Onto The Ground Mild Steel Guide Poles Shall Conform To Type Xl Sheeting Specifications As Per Lrc67 And Ast Ii D4956 Which Would Ensure To Obtainl Clear Visibility Of The Road Alignment During Nighl Time. The Relro Reflective Sheeting Shall Be Tested For Acertificale Of Having The Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Iiner Removal, Adhesion,Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdooa Weathering And Ils Having Passed These Tests Shall Be Obta Ned From Lnlernational/Government Laboratory / Lnslitute By The Manufacturer Of The Sheeinq And In Case The Cerliflcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condillon Within 3 Years Of Launching Of Product By The Manufaclure In Abroad. Alternatively, A Certillcate Conforming To Astlvl Specification (D4956 09) On Adficial Accelerated Weatherlng Requirements From A Reputed Laboratory In Lndia Can Be Accepted providing Sionally. Ln Such A Siluation, The Employer / Clienl, If So Desires, Collld Seek For A Performance Guarantee Which Would Be Released Alter Receipt Of Certiflcate Meeting The Requ Rement Of Three Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Report Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour. T&P, Transportation, Installation And Incidentals All Complete As Per D Recllon Of The Engineerincharge , Road Marking With Hot Applied Thermoplastic Compound With Reflectrosing Glass Beads On Bituminous Surface. Providing & Laying Of Hot Applied Thermoplastic Compound 2.5Mm Thick Including Reflecto Rising Glass Beads @ 250Gm/Sqm. Area, Thickness Of 2.5Mm Is Exclusive Of Surface Applied Glass, Beads As Per I.R.C. 35. The Finish Surface To Be Level Uniform And Free Form Steaks And Holes Composition Of Thermoplastic Material Shall Be As Per Table 800-3 Of Clause 803 Of Morth Including Cost Of Work As Per Direction E/Ic. (Chapter-28 Si.No.2) , Road Marking With Hot Appliod Ths.Moplastic Compound With Roflsctorlsing Glass Boads On Bituminous Surface. (Ropoated / Tranvers Bar) Providing And Laying Of Hot Applied Thermoplastic Compound 5 Mm Thick Lncludlng Reflectorising Glass Beads 0) 5Oo Gms Per Sqm Area, Thickness Of 5 Mm Is Exclusive Of Surface Applied Glass Beads As Per Irc:35-2015 The Llnished Surface To Be Level, Uniform And Free From Streaks And Holes , 6M Span Over Head Cantilever Structure With 300 Dia M S One Vertical Post Supply, Fxing & Erection Of Built Up Canllever Structure 6 M Span Comprising Of One Verllcal Posts Of 6.00 I!4 Helght Made Up Of 300 Mm Nb Heavy Class Ms Pipe As Verllcal Member Welded With 10 Mm I\,4S Plate At Top & 12 Mm M S Plate At Bottom. The Horizontal Truss Shall Comprise Of 50 Mm Dia Heavy Class M.S. Pipe And 40 Mm Dia Heavy M S Pipe As Bracing & 10 Mm Ms Plate At Bottom For Llxing To Vertical Post As Per Structure Design & Drawing Wilh One Of Steel Primer And Two Coats Of Synthetic Enamel Planl. The Work Includes Constrlrction Of Reinforced Cement Concrete Foundation Of Size 0.90X0.90X1 50 M Of Required Depth As Per Site Conditlon For Built Up Structure Including Earlh Work In Excavation 100 Mm Thick Lean Concrete In 113:6 Cement Coarse Sand And 40 Mm Gauge Stone Ballast And Reinforced Cement Concrete M25 Grade Concrete Including Supply And Fixing Of 25 Mm Dia Foundalion Bolts 600 Mm Long As Per Provision Of Structure Design Includlng Cost Of Reinforcemenl & Shuttering. The Lateral Vertical Clearances And Complete. Nstallaton Work Shall Be As Per Relevanl Clauses Of Mort&H Speciflcation Section 8Oo And Irc 67 2012 Complete In All Respect The Raies Shall Include Cost Of Deslgn Fabricalion, Supply, Kansportalion, Local Shifting Erection Of Signage Skucture Using Crane, Inclusive Of All Taxes Etc. All T&P Machine, Malerial And Labour Requiled For Proper Completion Of Work As Per Direclion Of Engineer-Ln-Charge. , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilhout Shank) , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilh Shank) , Flexible Median Marksr As Per Irc 79:2019: Flexible Lmedian N4arker (Flv4nl) Should Be Used For Improving Medlan Visib Lity Dlrring Dark Hours. , Use Of L/Edian ]Varker Provides Safely Againsl Colision Happening Wilh Med Ans During N Ght Lime , Or Sevete Weather Flexib E L\.4Edian Markers Shall Be Provided With Fluorescenl Yellow Colour Retro-Refleci Ve Sheeting Type Xl As Per Irc:87. Flexible Lt4edian Lmarker Shall Be Ol Lough, High Impact Resistant, Lnieclion Molded, Lhermoplastic Body With Propery Of Flexibility Io Provide High Durabilityand U Shape Structure Having Rebound / Bollnce Back Properly. The Sheeting Shall Be Of Type Xl Conforming To Lrcl67 And Ii Should Be On Both The Faces Whereby Providing Maximum Refleclivity At L,Anger Distances With Adequate Durabllity. The Logo Of The Manufacturer Shall Be Embossed On Either Side Of The Body During The Lnjection Molding Process. Fi\4M Shall Be Fixed By A Combination Bf Epoxy Adhesive And Grouting/ Drilling On Concrete Medians Or Property Conslructed Solid Medians Heighl: The Marker Height Shall Be A Minimum Of 180 Mm Width 120 Mm & Body Thickness: 6.5 Mm. The Shanks Shall Not Be Less Lhan 20 Mm And Depth Shall Not Be Less Than 30 Mm Reflective Area: Shall Not Be Less Than G0 Cm Square . Proof Of Lhe Same Report Shall Be Uploaded Which Quollng Lender. The Body Of Fn,4[,4 Shall Bounce Back To Ils Origlnal Position Of Afier 750 Number Of Hits Using Pendulum Of 1.8 Kg Conforming 40 Astm D256 Adhesion Between The Body And Outer Casing Body Of Fmi\4 Shall With Stand 50 Kg I Tensile Loads Conforming To Astm D63b Method. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer-Ln-Charge. , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Over 10 Cm. In Width , Linear Dstinoator Systsm (Lds) Supply & Fixing Of Linear Delineator System (Lds) Panels Made Of Micro Prismatic Retro Reflective Sheeting Type Xl Duly Laminated On Thin Aluminium Foil To A Unique Corrugated Shape To Provide Retro Reflection Across Wide Range Of Observaiions And External Angles. Eatch Lds Panel Should Be Of Nominal Lenglh Of 33 Inch And Each Ridge Shall Be Approximately 0.34 Inch High Each Lds Panel Is To Be Firmly Fixed On Existing Concrete/Brick Work With 16 Nos Fastner/ Screw , Retro-Roflectivesheeting Type-Lv With 4 Mm Thick Acm Single Side Providing & Flxing Of Reflective Signs With A Corrosion Resistant 4 Mm Thick Wlth 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Lace To Be Iully Covered With Hlgh Lntenslty Prlsmatic Sheetlng Type Lv As Per Irc-6712012 Relro Refleclive Sheeling With Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Elc Shollld Be As Per Morth Speciflcation No Bo1.3.7 .The Sheelng Shall Have A Pressure - Sensltive Adhesive Of The Aggressive - Tack Type Requiring No Heat , Solvent Other Preparation For Adhesion 10 A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acim (Aluminium Composite Materials) Shall Be Flxed On The Back Frame Nis Angle Wiih Riveting. Micro Prismalic Type Lv Retro Rellective Sheeting Conilrming 1O Astm 04956-09 Shall Be Pressure Lixed. The Retro Reflective Sheeting Shall Be Tested For A Cerlillcate Of Having The Sheeting Tesled For Coetllcient Of Retro Refleclion, Dayume Colour And Luminance, Shrinkage, Flexibilily, Liner Iemoval, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed Lhese Lesls Shall Be Obtained From Lnlemational/Government Laboratory/ Lnstitute By The Manufacture. Of The Sheetng And In Case The Certiflcate Is Oblalned From International Condilion, T Should Also Be Obtained From Lndian Condilion Within 3 Years Of Launching Of Producl By The Manufactllre In Abroad. Alternalively, A Cerliilcate Conforming To Astm Specification (D 4956-09) On Artiilcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, Lhe Employer/Client, If So Desires, Could Seek For A Petlotrnance Guarantee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirement Of Lhree Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo.T Shall Be Uploaded Whlch Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Lransportation, Installation And Lncidentals All Complete As Per Direction Of The Eng Neer-In-Charge. , Retro-Reflectivesheeting Type Iv With 4 Mm Thjck Acm Double Side: Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Lhlck With 0.4 To 0.5 Mm Both Side Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Tntensity Prismaiic Sheeling Type Lv As Per Irc-67:2012 Retro Reflective Sheeting With Back Frame Ms Angle Of 35X35x5 Mm Legends Letters , Numerals And Borders Elc Should Be As Per Morth Specification No801.3.7 The Sheeting Shall Have A Pressure - Sensitive Adhesive Of The Aggressive - Tack Type Requiring No Heai, Solvent Olher Preparation For Adhesion To A Smooth Clean Surface, Ln A Manner Recommended By The Sheeling Manufacturer. The Acn,4 (Aluminium Cornposite L\,4Aterials) Shall Be Ilxed On The Back Frame Ms Angle With Nveling. Micro Prismatic Type Lv Retro Refleclive Sheeting Conflrming Io Astm D4956-09 Shall Be Pressure Llxed. The Reko Reflective Sheeling Shall Be Tesled For A Cedificate Of Having The Sheeting Tested For Coemcient Oi Reko Reflection, Daytime Colour And Luminance, Shrinkage Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdoor Weatherlng And Its Having Passed These Tests Shall Be Obtained From Lnternallonal/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeting And In Case The Certificale Is Oblained From International Condition It Should Also Be Obta Ned From Lndian Condilion Wilhin 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certilicate Conforming 10 Astm Speciflcatlon (0 4958-09) On Aatiflclal Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepled Provisionally. Ln Sllch A Situation, The Employer/Client If So Desires, Could Seek For A Performance Guarantee Which Would Be Released Afler Receipl Of Cerlillcate Meeting The Requirement Of Lhree Years Outdoor Weathering Of The Sheeling As Per Irc 67I2012 & Proof Of The Same Repofl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installalion And Incidentals All Cornplete As Per Dlreclion Of The Engineer-In-Charge , Retro-Refle.Ctivesheeting Type-Xl With 4 Mm Thick Acm Single Side Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Thick With 0.4 To 0.5 Mm Both Slde Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Lntensity Prismatlc Sheeting Type Lv As Pet Irc-67:2012 Reko Reflective Sheeling With Back Frame L\,4S Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per L\Lorth Specification No_ 801.3.7 The Sheeting Shal Have A Pressure - Sensitive Adhesive Of The Aggressive Tack Type Requiring No Heal Solvent Other Preparation For Adhesion To A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acm (Alllminium Composite L\,4Aterlals) Shall Be Fixed On The Back Frame Ms Angle With Riveting. Micro Prismatic Type Lv Retro Reflective Sheeung Conflrming To Astlvl D4956-09 Shall Be Pressure Fixed. The Relro Reflective Sheeting Shall Be Tested For A Cefiilicate Of Having The Sheeting Tested For Coeificient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Iungus Resistance. 3 Years Outdoor Weathering And Lts Having Passed These Tests Shall Be Obtained From Lnlernational/Government Laboraiory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cefiificate Ls Obtained From Lnternational Condition. It Should Also Be Oblalned From Lndian Condition Wilhin 3 Years Of Launching Of Producl By The Manufacture In Abroad. Alternatively, A Certificate Conforming To Astii Speciflcation (D 4S5b-09) On Adiflcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Prcvisionally. Ln Such A Siluation, The Employer/Client, If So Desires, Could Seek For A Performance Guaranlee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirernent Of Three Years Outdoor Weathering Of Lhe Sheeting As Per Irc 67:2012 & Prooi Of The Same Reporl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpoftalion, Installation And Incldentals All Complete As Per Direction Oi The Engineer-Ln-Charge , Retro-Reflectlveshoeting Type-Xl With 4 Mm Thick Acm Double Side Providing & Rlxing Of Reflective Signs With A Colrosion Resistanl 4 Mm Thick With 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Face Lo Be Iully Covered With High Lntensity Prismatic Sheeling Type Lv As Per Irc-67:2012 Relro Retlective Sheeting Wlth Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specification No_ Bo1.3.7 .The Sheeting Shall Have A Pressure - Sensilive Adhesive Of The Aggressive - Tack Type Requiring No Heat, Solvent Other Preparation For Adhesion Lo A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer, The Acn,4 (Aluminlum Composite Materlals) Shall Be Fixed On The Back Fiame Ms Angle With Riveting. Micro Prismalic Type Lv Retro Reflective Sheeting Conflrming To Astm D4956 09 Shall Be Pressure Fixed. The Relro Refleclive Sheeting Shall Be Tested For A Ce(Iilcate Of Having The Sheeting Tested For Coefllcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Funqus Resistance. 3 Years Outdoor Weathering And Its Having Passed These Tests Shal Be Oblained From Lnternationa /Governmenl Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case Lhe Certillcate Ls Obtained From Internalional Condition, It Should Also Be Obtained From Lndian Condition Within 3 Years Of Launching Of Product By The Manufacture In Abroad Alternalively, A Ce(Iilcate Conforming To Astm Specification (D 4956-09) On Artiflcial Accelerated Wealhering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Sltuation, The Employer/Cllent, If So Deslres Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cedillcate Meeling The Requirement Of Lhree Years Outdoor Weathering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo( Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpo.Tation, Installation And Incidentals All Complete As Per Direction Of The Engineer-In-Charge , Bollard (Single Sido) Supply & Fixing Of Bollard Made(Single Side) Out Of2mm Thick Aluminium Sheet Face Lo Be Covered With High Intensity Prismatic Grade Type Lv Sheeting , Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specillcation No-801.3.7 . Welded Poly Shaped To Make It Monolithic Pillar Size 12Oo Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Is Fully Cover (Size Of Foundation 0.45X0.45X0.60M) , Bollard (Doublo Side) Supply 8, Fixing Of Bollad Made (Double Side) Out Of 2Mm Thick Aluminium Sheet Face To Be Covered With High Intensity Prismatic Grade Iype Lv Sheeting Legends , Letters , Numerals And Borders Etc Should Be As Per Morih Specification No-801.3.7. Welded Poly Shaped To Make It Monolithic Pillar Size 1200 Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Ls Fully Cover. (Size Of Foundalion 0.45X0.45X0.60M) , Solar Power Road Marker (Solar Studs) The Solar Studs Shalt Be Made Of Aluminium Alloy And Poly Carbonate Material Which Shall Be Absolutely Weather Resistant And Strong Enough To Support A Load Of 13,635 Kg Tested In Accordance With Ast[4 D4280. Lts Co]Our May Be While . Red , Yellow , Green Or Blue Or Combination As Directed By The Engineer . Its Water Resislance Shall Meet Lhe Requiremenls Of Lp 65 In Accordance Wilh 15:12063:1987 Category 2 For Protection Againsl Water Ingress The Dimensions Of Solar Sluds Shall Not Be Less Than 100 Mm X 100 Mm X 10 Mm Ltshall Have Super Bright Leds So As To Provide Long Visibillty From A Distance Of More Than B0o M. Lts Flashing Rate Shall Not Be Less Than1 Hz Lts Should Be Able To Glve The Prescribed Performance In The Temperrature Range Of - 40C To +55C Lts Life Shall Be Not Less Than 3 Years. The Rate Shall Include All Materials, Labour, Equipments, Fabrication, Transportation, Erecuon, Installation And Incidentals All Complete As Per Direclion Of The Englneer-In-Charge , Cast-Ln-Situ Cement Concreto M 20 Kerb Construction Of Cement Concrete Kerb With Top And Bottom Width 115 And 165 Mm Respectively, 250 Mm High In M 20 Grade Plain Cement Concrete On M-10 Grade Foundation 150 Mm Thick, Foundation Having 50 Mm Projection Beyond Kerb Stone, Kerb Stone Laid With Kerb Laying Machine, Foundation Concrete Tad Manually, Alt Complete As Per Clause 408. , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 90 Cm Equllateral Tringle With Dif,Lnitation Plate Size (20Cm X 60Cm , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Eqlrilateral Trinqle With Difflnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Circular With Difflnltation Plale (20Cm X 60Cm) . , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government B0 Mm X 60 Mm Reclangu annual repair With Difllnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Mm X 45 Mm Rectangular With Difllnitation Plale (2Ocm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm X 60 Cm Square With Difflnitation Plate (20Cm X 60Crn) , Direction And Place Identification Signs Up To 0.90 Sqm Size Board Providing And Erecting Directlon And Place Identification Retro Reflectorised S Gn As Per Irc-67 Made Of High Intensily G.Ade Sheeting The Relro Reflective Sheelng Shall Be Tested For A Certiicate Of Having The Sheeling Tested For Coefficient Of Reko Reflection. Daytime Colour And Luminance, Shrinkage, Flexibllity. Liner Removal Adhesion, Impacl Resislance, Specula. Gloss And Iungus Resistance, 3 Years Ouldoor Weathering And Its Having Passed These Tesls Shall Be Obtalned From Lnternational/Govemment Laboraiory/ Lnslitule By The Manufacturer Of The Sheeting And In Case The Certillcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condltion Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certiflcate Confonning To Ast[4 Specification (D4956 09) On Art Ficial Ccelerated Wealhering Requirements Faom A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer I Client, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Lhree Years Olrtdoor Weathering Of Lhe Sheeting As Per Irc 67 2012. Legends , Letters , Nurrerals And Borders Etc Should Be As Per Imorth Speciilcation No-801.3.7 Sheet Fixed Over Aluminium Sheetinq .2 Mm Thick Wilh Area Not Exceeding 0.9 Sqm.Supported On A Mild Steel Single Angle Iron Post 75X75x6 Mm Flrmly Fixed Lo The Ground By Rneans Of Property Designed Foundalion With N,4-15 Grade Cement Concrete 45X45x60 Cm.,Below Ground Lcvcl As Pcr Approvcd D.Awing. Complete. , Tree Plats Supply & Fixing Of Retro Reflective Tree Plate Having Size 15Cm X15cm, Conjisiing Type Xl Retro Reflective Sheeting Lixed Over 1.50 Mm Thick Aluminiu; Sh;Et Including Labour, Material T&P Etc For Proper Completion Of The Work. The Rate Shall Include All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 1000 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 750 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 500 Mm Helght , Aluminum-Backed Flexible Prismatic Sheeting Shall Be Made Of Yellow Colored Flexible Prismallc Sheeting With Non-Rnetallic Prismatc Lens Formed In A Lransparent, Synthelic Resin As Retro Leflective Elements. This Llexible Prlsmatic Sheeting Shall Have Black And Yellow Stripes With Aluminum Backed Flexible Prismatic Type Vl Sheeting Conforming To Astm: D4956 . Specifications And Standards Of Coefllcient Of Relro Refleclivity, Flexibility And Lmpact Resislance Applicable For Reboundable Devices This Flexible Prismatic Sheeting Shall Have Screen Printed Arrow/Slant Line Pattern In Black Colour In A Continuous Roll Format. Wldlh Of Object Marker Shall Be 300 Mm. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer In-Charge , 2.40 M Span Over Head Cantilever Structure With 150 Die Ms One Vertical Post (Double Side Retro Reflective Sign Boards) Supply, Fixing & Eraction Of Built Up Cantilever Structure 240 M Span O.PiiIng Oi One Ve.Tical Posts Of 7 30 N4 Heighl Made Up Of 150 Mm Nb Medium Class T\4S Pipe As Vertical Memberwelded With 10 Mm Ms Plate At Top & Lo Mm Lvls Plate At Boltom. Flxing To Vertical Post As Per Structllre Design & Drawing Wiih One Of Steel Primer And Two Coats Of Synthetic Enamel Plant And The R;Tro Reflective Sheetinq Shall Be Tesled For A Certifcale Of Having The Sheeting Tested Fo. Coemcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Olltdoor Wealhering And Ils Having Passed These Lests Shall Be Obtained From Lnternational/Government Laboraiory/ Lnstitute By The Manufactllrer Of The Sheeting And In Case The Certificate Is Obtained From Internatlonal Condilion, It Should Also Be Obtained From Lndian Condition Wilhin 3 Years Of Launchlng Of Product By The Manufacture In Abroad. Alternatively, A Cedificate Confonning Io Astm Speciflcation (0 4956 09) On Artificial Accelerated Weathering Reqllirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. N Such A Sltuation, The Employer / Client, If So Desiaes. Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerllllcate Meeting The Requirement Of Three Years Outdoor Weathering Ol Lne Sheeling As Pel Irc 67 2012 . Legenos . ,Etters . Numerdls And Borders Elc Sholllo Be Asperl\,4Orlh Specif,Calion No_801 37 The Work Includes Construction Of Reinforced Cement Concrete Foundation Of Size 0.60X0.60X1.20 M Of Required Depth As Per Site Condilion For Built Up Struclure Lncluding Earth Work In Excavation 100 Mm Thick Lean Concrete Ln 1:3:6 Cemenl Coarse Sand And 40 Mm Gauge Stone Ballast. Reinforced Cement Concrete Lm25 Includlng Supply And Fixing Of 25 Mm Dla Foundalion Bolts 600 Mm Long As Per Provision Of Slructure Design Including Cost Ot Reinforcement & Shuttering. The Lateral Vertical Clearances And Complete. Lnstallation Work Shall Be As Per Relevant Clauses Of Mort&H Specitlcation Seclion 800 And Irc 67 2012 Complete In A I Respect The Rates Shall Inclucle Cosl Ol Design Fabrication, Supply, Lransporlalion, Local Shifling Erection Of Signage Slructure Using Crane, Incluslve Of All Taxes Etc All T&P Machine, Material And Labout Required For Proper Completion Of Work As Per Direction Of Engineer-In-Charge , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 30X90 Cm (Lefrright) Object Hazard , Retro Rellectorisod Signs (Stajnless Steel Frame And Post With One Side Sings) Supply & Fixing Of Reflective Sign Board (Single Side) Of Size 1.50X1.20 M Retro Refleclive Sheeling Of Hip Grade Type-Lv, Lhe Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick, Acm Sheel Of Standard Make As Per Morth Specificaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Cm Cement Conclete Foundauon. The Stainless Steeljoint Welding Of Ss Pipe Work Shall Be Band And Grinder Property Including Bufflng So An To Give Uniiorm Shining At Weded Joinls. The Retro Reflective Sheellng Shall Be Lested For A Certiflcate Of Having Ihe Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Cololrr And Luminance, Shrinkage, Flexibility, Linet Removal, Adheslon, Impact Resistance, Specular Qloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Governmenl Laboratory/ Institute By Lhe Manufacturer Of The Sheeting And Ln Case The Cedillcate Is Obtained From Inlernational Condition, It Should Also Be Oblained From Lndian Condition Within 3 Years Of Launching Of Procluct By The Manufacture In Abroad Allernatively. A Certiflcate Confolrnlng To Astm Specilicalion (D 4956-09) On Artiflcial Acceleraled Weathenng Requirements From A Reputed Laboratory Ln Lndia Can Be Accepled Provislonally. Ln Slrch A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificale Meeting The Requirement Of Three Years Ouldoor Weathering Of The Sheeting As Per Irc 67I2012. Legends , Letters , Numerals And Borders Elc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Governmenl Repod Shall Be Uploaded While Quoting Tender. , Retro Reflectorised Signs (Stainless Steel Frame And Post With Both Side Sings) Slrpply & Fixing Of Reflecllve Sign Board (Sing E Side) Of Size 1.50X1.20 M Retro Reflective Sheeting Of Hip Grade Type-Lv, The Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick Acni Sheet Of Standard Make As Per Morth Speciilcaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Crn Cement Concrele Foundation The Stainless Steelioint Welding Of Ss Pipe Work Shallbe Band And Grinder Propefiy Including Butting So An To Give Uniform Shining At Weded Joints. The Relro Reflective Sheeting Sha I Be Tested For A Certificale Of Having The Sheeling Tested For Coefficient Of Retro Reflection Daytime Colour And Luminance, Shrinkage. Flexibiity, Llner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Reslstance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeling And Ln Case The Certiflcate Is Obtained Lrom Lnternational Condition, It Should Also Be Obtained From Lndian Condition Wlthin 3 Years Of Launching Of Product By The Manufacture In Abroad. Allernatively, A Cerlificate Conforming To Astm Specificalion (0 4956.09) On Artificial Accelerated Weathering Requlremenls From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificate Meeting The Requirement Of Three Years Outdoor Weather Ng Of The Sheeting As Per Irc 67I2012. Legends. Letters, Numerals And Borders Etc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Government Report Shall Be Uploaded Whlle Quoting Lender. , Type - A, W : Metal Beam Crash Barrier Providing And Erecting A W Metal Beam Crash Barrler Comprlsing Of 3 Mm Lhick Coffugated Sheet Melal Beam Ral 70 Cm Above Road/Ground Level Flxed On Ismc Series Channel Vertical Posl, 150 X 75 X 5 Mm Spaced 2 M Centre To Centre, 1.8 M High. 1.1 M Below Grolnd/Road Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fltlings To Conform To Lsi1367 And 15:1364. Metal Beam Rail To Be Fixed On The Vedical Post With A Spacer Of Channel Section 150 X 75 X 5 Mm, 330 Mm Long Complete As Per Clause 810 , Type - B, Thrie : Metal Beam Crash Barrier Providing And Erecting A Thrie Metal Beam Crash Barrier Comprising Of 3 Mm Thick Corrugated Sheet Melal Beam Rail,85 Cm Above Road/Ground Level, Fixed On Isi\Ic Series Channel Vertical Post, 150 X 75 X 5 Mm Spaced 2 M Cenlre To Cenke, 2 M High With 1.15 M Below Ground Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fittings To Conform Lo Lsl1367 And Ls:1364 Metal Beam Rail 10 Be Fixed On The Verlical Post With A Space Of Channel Seclion 150 X 75 X 5 Mm, 546 Mm Long Complete As Per Clause 810 , Anti-Termite Treatment The Soil Along With External Perimeter Of Building At The Rate Of 2.5 Litres Of Emulsion Per Square Metre Of The Perimeter Wall {Chapter No.08 Si.No.5} , Anti-Termite Treatment Of The Bottom And Sides Of Excavation At The Rate Of 5Litres Of Emulsion Per Square Metre Of Surface Area {Chapter No.08 Si.No.1} , Anti-Termite Treatment Of The Top Surface Of Filled Earth At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface{Chapter No.08 Si.No.3} , Anti-Termite Treatment Of The Soil Under Plinth Protection At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface {Chapter No.08 Si.No.4} , Anti-Termite Treatment Of The Backfill In Contact With Foundation At The Rate Of 7.5 Litres Of Emulsion Per Square Metre Of Vertical Surface (Area Of The Sub Structure In Contact With Backfill To Be Measured) {Chapter No.08 Si.No.2} , Treatment Of Existing Masonry Using Chemical Emulsion @ One Litre Per Hole At 300 Mm Interval Including Drilling Holes At 45 Degree And Plugging Them With Cement Mortar 1:2 (1 Cement :2 Coarse Sand) To The Full Depth Of The Hole : With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration {Chapter No.08 Si.No.6-2.35.4.1} , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration {Chapter No.08 Si.No.6-2.35.3.1} , Providing And Stacking 22.40-53Mm Guage Stone Aggregates Of Specific Sizes To Water Bound Macadam Specification Including Etc All Complete.(Ns) , Supply And Laying Stone Dust Etc All Complete. , Consolidation/Compaction Of Stone Ballast 10Cm Thick (Loose) Coat Including Repairing Of Patches Picking Up To Old Surface Spreading, Ballast Making Medhies To Retain Water And Carriage Of Metal Upto 30M Carriage Of Water Upto 200M Maintenance Of Barriers And All Labour T&P Including Road Roller Charges Etc. Required For Proper Completion Of Work The Stone Ballast Is To Be Supplied To The Contractor Free Of Cost At Site. , Scarifying The Existing Bituminous Road Surface To A Depth Of 150 Mm And Disposal Of Scarified Material With A Lift Upto 3 M And Lead Upto 1000 M As Per Technical Specification Clause 301.4 {Chapter No.20 Si No.16} , Providing And Applying Primer Coat With Ss1 Grade Bitumen Emulsion On Prepared Surface Of Granular Base Including Clearing Of Road Surface And Spraying Primer At The Rate Of 0.70 Kg/Sqm Using Mechanical Means. (As Per Attached Analysis) , Providing And Laying Dense Graded Bituminous Macadam With Higher Capacity Batch Type Hmp Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder @ 4.5 Per Cent By Weight Of Total Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification Clause No. 505 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , Providing & Applying Tack Coat With Bitumen Vg-10 Using Bitumen Pressure Distributor At The Rate Of 0.30Kg/Sqm. On The Prepared Primed Granular/Old Painted Surface. Cleaned With Air Compressor. Including All Taxes, Material, Labour, T&P Etc Required For Proper Completion Of The Work. (For Bituminous Surface). (Chapter No.20 Si No.9) , Providing And Laying Bituminous Concrete (Grading-Ii) With 100-120 Tph Hot Mix Plant Producing An Average Output Of 75 Tonnes Per Hour Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder Vg-30 As Per Approved Job Mix Formula Which Ever Is Higher Of Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification 5Th Revision Clause No. 509 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , S/L/J Of 20Mm Dia Pvc Cunduct Pipe Etc. All Complete. , Making Of Nala Bandha With Sand Bags. With Local Sand Including Etc. All Complete. (Atached Per Annalysis Rate). , Providing Of Nala Bandha For Diversion Of Nala Etc All Complete.(Ns) , Scraping Of Max Phalt Road Including Disposal Of All Scraped Material To A Distance Of 30Mtrs (100 Ft) As Directed By Engineer-In-Charge C.P. & T&P.Etc. All Complete. {Chapter No.20 Si No. 772(A)} , Dismentling Existing Damage Plaster Including Disposal Of Refuse As Directed By E/Ic With In A Distance Of 60 Meters Etc. All Complete. {Chapter No. 17 S.I. No.16 (706)} , Supply And Fixing Of Light Fitting Switch Board. (None Sheduled) , Fixing Of Gate, Grill And Jali Etc. All Complete. (None Scheduled) , Supply & Fixing Of Wiring Sub Main. , Supply & Fixing Of Plug Point 15Mm. , Supply And Fixing Oxided Iron Fitting Etc. All Complete (None Scheduled) , Supply/Fixing Of 16 Mm Pvc Pipe Adopter Suitable For Item No. , Supply/Fixing Of 20 Mm Cvc Pipe Adopter Suitable For Item No. , Supply & Fixing Of 27Watt. Cfl Etc. All Complete. , Supply And Fixing Cat Eye Including Supply Of All Material, Loabour, T&P Etc. All Complete. (Chapter No.28 Si.No.5B) , Supply And Fixing Wiring Of Light Point. (None Sheduled) , Making Connection Of Drain Of Sewer Line With Existing Man Hole Including Breaking Into And Making Good The Walls, Floors With Cement Concrete 1:2:4 Cement Plastered On Both Side With Cement Mortar 1:3 Finished With A Floating Coat Of Neat Cement And Making Necessary Channels With Cement Concrete 1:2:4 For The Drain Etc. All Complete. (Chapter No.25 Si.No.9) , Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Course Sand : 4 Graded Stone Of Size 20 Mm Nominal Size) Laid In One Layer Finished With A Floating Coat Of Neat Cement (40 Mm Thick Floor). (Si No. 665), Nbo 14.71) , Providing And Fixing Of Foot Steps Etc All Complete. (Ns) On Market Rate , Providlng And Fixing C.P. Brass Bib Cock Of Approved Quality Conforming To Ls:8931.15 Mm Nominal Bore , Supply & Fixing Of C.P. Brass Stop Cock (Conceled) Of Standerd Design Of Approve Quality Etc. All Complete. (Chapter No.21 Si.No.44) , Providing And Fixing Close Timbering In Trenches On Both Side & All Complete. (A) 0.00 To 3.00 M. (None Scheduled) , Providing And Fixing C.P. Brass Stop Cock (Concealed) Of Standard Design And Of Approved Make Conforming To Ls:8931..15 Mm Nominal Bore , Fixing Window Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Ls Standards And Weighing Not Less Than 690 Qms.15 Mm Nominal Bore , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 75Mm Diameter. (Chapter No.23 Si.No. 32(Ii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 110Mm Diameter. (Chapter No.23 Si.No. 32(Iii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 140Mm Diameter. (Chapter No.23 Si.No. 32(Iv)) , Rectangular Shape 1500X450 Mm Mirror With Plastic Moulded Frame. (Chapter No.22 Si.No.77) , Making Ornamental 2D Painting With Special Design Make By Specialist Painter Laying Of Two Coat Birla White Putty And Design By Asian Paint Including All Material Etc. All Complete. (Nn Approved) , Providing Of 8Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Fixing Door Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Supply And Fixing 6Mm (1/4) Thick Chine White Glazed Tiles In Flooring Or Dado Laid With 1:3 Cement And Approved Coarse Sand Mortar And Approved Coarse Sand Mortar Finished With White Cement Jointed And Polishing Complete Including Supply Of All Materials, Labor For Porper Completion Of The Work. (Chapter No.14 S.I. No. 628) , Supply & Fixing Of Pre-Cast M-30 Cement Concrete Grass Paver (Rubber Molded Coloured) Over 40Mm Thick Local Sand Bed, With 3Mm Thick Joints Filled With Local Sand Including Leveling, Tempering And Sweeping Etc., Interlocking Bricks Will Be As Description Given In Direction Issued By The Ircsc-03-2004 And Should Be Isi Marked All Complete. 80Mm Thick, Strength Should Not Less Than M-30. (Tiles I Shape Decided By Engineer-In-Charge With Isi Mark) {Chapter No.20 Si.No.17F) , Repairing Of Leakage And Damege Pipe Line Etc All Complete.(Ns) , Lettering & Painting Of Wall Etc. All Complete. , Red Sand Stone Work For Wall Lining Etc. (Veneer Work) 30Mm Thick In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Camping Jointing In White Cemnet Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching Complete. (Chapter No.18 Si.No.1 New) , Providing And Fixing White Vitreous China Wash Basin Size 630X450mm With Pair Of 15Mm C.P. Brass Pillar Taps Including Etc. All Complete. (Chapter No.24 S.I. No. 3(A)) , Cleaning Of The Site For Workable Etc. All Complete. (Non Scheduled) , Providing Of 32Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 1200X600x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 600X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x100mm Etc All Complete. (As Per Market Rate) , Fixing Of Reinforced Cement Concrete Slab Etc All Complete. (Ns) , Raising & Re-Fixing Of Manhole Including All Material Labor T&P Etc. All Complete. (Non Scheduled) , Supply & Fixing Reinforced Cement Concrete Menhole Cover Heavy Duty Size Etc. All Complete. (Non Scheduled) , Providing Laying Spreeding And Compacting 45-90Mm Stone Agreegate For W.M.M. Specification Etc. All Complete. (None Scheduled) , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing Of 3D Ornamental Wall Art Painting By Architect & Special Painter Including Scrapping Of Wall And Two Coat White Putting White Putty One Coat Primer All Labour Scaffolding Work & Labour T&P Etc. Painting By Asian Special Paint Etc. All Complete. (Rate Mr As Smart City, Agra) , Providing, Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes To Water Bound Macadam (22.40-53Mm) Specification Including Spreading In Uniform Thickness, Hand Packing, Rolling With 3 Wheeled Steel/ Vibratory Roller In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening/ Binding Materials To Fill Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density. , Providing & Laying 5Cm. Thick B.M. Laying By Paver Finisher Bitumen Of The @3.4%Kg By Weight And Stone Grit Etc. All Complete. (20-Chapter Analysis Rate) , Providing & Laying 2.5Cm. Thick S.D.B.C. Laying By Paver Finisher Bitumen Of The 5% By Weight Etc. All Complete. (20-Chapter Analysis Rate) , Supply & Fixing M/S Iron Work Display Board Including Painting, Lettering Etc. All Complete. (None Schedule) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.4A) , Supply And Fixing Of Precast Reinforced Reinforced Cement Concrete Benches (Pfrc) Ornamental Benches With 02 Year Warranty Etc All Complete. (None Scheduled) , S/L/F Supply Of 1000Mm Dia Np-3 Reinforced Cement Concrete Hume Pipe In Proper Position As Directed By E/I Including Catage Of Pipes Collars Upto 30M Distance Etc All Complete. (Chapter No.1 Si.No.31(E) ) , Reinforced Cement Concrete Work With Cement Approved Coarse Sand And 2Cm (3/4) Gauge Approved Stone Ballast In The Proportion 1:2:4 In Reinforced Cement Concrete Slab Excluding Supply Of Reinforcement And Its Bending But Including Its Fixing And Binding The Same With 24 Bwgi Binding Wire And Including Necessary Centring And Shuttering Etc. And Also Including Supply Of All Materials Labor And Tools And Plants Etc. Required For Proper Completion Of The Work. Strength Of The Concrete Shall Not Be Less Than M-150. (5-Chapter S.I. No.-284) , Supply & Fixing Granite Stone Work Display Board (Size 2.50Ft X 4.00Ft) Including Painting, Lettering Etc. All Complete. (None Schedule) , Installation Of 1.50 H.P. Isi Marked Sumbercible Pump Etc All Complete. (Attache As Per Santion Annalysis) , Cost Of Septik Tank Attache As Per Estimate & Details. , Plain Glass Best Quality, Cut To Size 5Mm Thick , Providing And Fixing Designer Dustbin (Market As Per Catlog Code No. Db-03). , Supply Of Planting Of Trees Amaltas, Jaarul, Arjun Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 110Mm Is:4984:2016 (As Per Market Rate) , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 160Mm Is:4984:2016 (As Per Market Rate) , Supply & Fixing Of Pre-Cast Reinforced Cement Concrete Drain Cover Different Size Etc All Complete. , Supply And Sowing Of Grass In Park Including One Year Mantinance Etc. All Complete. (None Scheduled) , Supplying And Stacking Of Good Earth At Site Including Royalty And Carriage Upto 8 Km Lead Complete (Earth Measure Dinstacks Will Be Reduced By 20% For Payment) .(Dar 2020 Hort-Basic Rates 2.2) Based , Supply And Fixing Of Light, Fitting Switch Board. (None Sheduled) , Supply And Fixing Of Chest Press Double. , Supply And Fixing Of Leg Press Double. , Supply And Fixing Of Triple Twister. , Supply And Fixing Of Shoulder Builder Double. , Supply And Fixing Of Air Walker. , Supply And Fixing Of Doublebar. , Supply And Fixing Of Rower. , Supply And Fixing Of Horse Rider. , Supply And Fixing Of Plastic Side With Iron Ladder 12 Feet Length. , Supply And Fixing Of See Saw Double Board Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Sliding With Swing Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Slide Ground Level Mgr Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Snack Climber Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Slide Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Nursery Combo Set Revolving Jhoola Etc All Complete. (None Scheduled) , Providing And Fixing Of Stainless Steel Water Cooler 4 Tap Etc. All Complete. (None Schedule) , Supply And Fixing Bansi Paharpur (Red/White) Bharra Sand Stone Fully Moulded, Engraved, Carved With Polishing And Dressing Including Clamp And Fashners Of Pillar Set With All Complete Work Etc. (None Schedule) , Supply & Fixing Of Rubber Moulded Cement Concrete Kerb Stone (Double Tapper) M-20 With Labour T&P Etc All Complete. , Supply And Installation And Jointing Of 500Mmx500mm Epdm Rubber Mat Flooring Of Thickness 24Mm Puling All Labour Material T&P Etc. All Complete (Rate As Per Jhs Jscl Mr). , Providing And Laying Autoclaved Aerated Cement Blocks Masonry With 150Mm/230Mm/300Mm Thick Aac Blocks In Super Structure Above Plinth Level Up T Floor Five Level With Reinforced Cement Concrete Band At Sill Level And Lintel Level With Approved Block Laying Polymer Modified Adhesive Mortar All Complete As Per Direction Of Engineer-In-Charge (The Payment Of Reinforced Cement Concrete Band And Reinforcement Shall Be Made For Separately). , Providing And Fixing Of Barricading Of 100Mm Average Ballies With In A Distance Of 1.50 Meter For 3 Rows Of 3Q. 3 Nosof Cross Ballies, Two Supporting Ballies Of 3 Meter Ballies And 2 Nos Perpendicular Ballies Tie With Moonj Rope Including Supply Of All Material Such As Ballies Rope T&P Required For Proper Completion Of Work And Also Including Labour Component (Material Will Be Property Of Contractor After Dismantling). , Providing & Fixing Of Green/White Shade Multipurpose Net/Cotton Cloth Proper Completion Of Work Etc All Complete. (Ns) , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Supply And Fixing Of Ward Up Big As Per Attach Photograph & Analysis. , Supply And Fixing Of Ward Up Small As Per Attach Photograph & Analysis. , Supply And Fixing And Installation Of See Saw Double Board Jhoola Isi Marked As Per Direction Of Engineer-In-Charge Etc. All Complete As Per Attach Photograph & Analysis. , Supply And Fixing Of Cast Iron Banches As Per Attach Photograph And Analysis And Direction Of Engineer-Incharge Etc. All Complete. , Complete De-Silting And Cleaning Of All Types Of Sewer Lines By Using Super Suction Machine And Taking Out Of Cebris/Silt Etc Including Safe Disposal Of Silt As Directed By The Deptt. Including Cost Of All Consumble Likes Disel Oil, Water Ret Provision Of Diversion Of Line If Required With The Help Of Sewage Pumps, Poser Backup From Gene Sets For Running Of Pumps. Night Lighting Etc Barricades Display Of Entire Operation Along With Sadequate Safely Equipments Must Be Used By Sewer Workers Size Fo Sewer Line To Be Desilted As Detail Above 1000Mm Dia. , providing and laying Gsb With Graded Stone Ballast With Stone Grit Size Stone Ballast With Hand Ramming Watering Including All Material Labor T&P Etc.All Complete (Ns) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Providing & Laying Of Polythene Etc. All Complete. , Supply & Fixing Of Factory Wired Intergal Led Flood Light Luminaries With Die Cast Aluminum Housing Built With Driver Set Suitable For 140W. To 150W. Confirming To Ip 65 Protection Complete In All Respect. Cat Aaa ( S.I No. 1454 Pwd Schedule 2018) , Providing, Laying, Spreading And Compacting Stone Aggregates 45-63Mm Of Specific Sizes To Water Bound Macadam Specification Including Spreading In Uniform Thickness, Hand Packing, Ro Ling With Smooth Wheel Roller 80-100 Kn In Stages To Proper Grade And Camber, Applying And Brooming, Stone Screen Ing/Bindin G Materials To Fill-Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density Grading 2 As Per Technical Specification Clause 405. (Labour , A Pre-Laminated Sheet, Often Referred To As A Prelam Sheet, Is An Engineered Myka Wood Work Product Where A Decorative Layer, Like Laminate Or Veneer, Is Pre-Attached To A Core Material Like Particleboard Or Mdf. These Sheets Offer A Durable And Aesthetically Pleasing Surface For Furniture, Interior Design, And Construction.(None Scheduled) , Same Is Ltme No-1 & Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters (Over All Area Of Door Shutter To Be Measured) , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration (Chapter No.8 Sr.No.6.1) , Supply And Fixing Of Advertisement Sign Board Size 4X3 As Per Direction Of Engineer-In-Charge Etc. All Complete , Supply Of Planting Of Trees Washington Palm, Amaltas, Cycus Revoluta, Ficus Benjamina Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Providing Of Rain Water Harvesting Drawing And Analysis Etc. All Complete (Details Attached). , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Drilling Of 200Mm Dia T/W Bore Suitable For 110Mm Dia Pipe All Complete With Labour T/P As Per Direction Of Engineer-In-Charge. , Suppply And Lowering Of 110Mm Dia 6 Kg/Cm2 Pvc Pipe (Phenolex Or Apb By E/I) All Complete. (Isi Marked Only) , Supply And Pouring Of Pea Gravel Suitable For T/W Bore All Complete. As Per Direction Of E/I (If Required) , S/L Of 1.50 H.P. Submersible Pump Set 65 Mt Head. (Pluga, Crompton, Ksb Etc.) I.S.I. Marked Etc All Complte. (Water Filled Only) , Supply & Fixing Of 100Mm Pvc Pipe Adopter Suitable For Item No.2 , S/L Of 1.50 H.P. Submersible Motor Controlled Starter Pannel All Complete. Crompton Make. (I.S.I. Marked Only) , Supply/Fixing Of 25Mm Gate Valve All Complete. Approved Make. , Supply/Fixing 4Sq.Mm 3 Core Copper Cable All Complete. , S/L Of 40Mm Dia Red Screen Ashirbad Pvc Pipe All Complete. , Supply/Fixing Of M.S. Clamp Made With 65X6mm X600mm Long M.S. Streep Suitable For 110Mm Dia Pvc Pipe For Holding All Complete. , Supply/Fixing Of 40Mm Dia G.I. Pipe B-Class Complete With Labour Charge. (Including All G.I. Fitting) , Supply & Fixing Of 25Mm Cpvc Etc. All Complete. , Development Of Bore Till The Discharge Is Free From Turbidity Of Compression Including Labour, Required For Proper Completion Of Work. , Supply And Fixing Of Precast Readymade Boundry Wall Hieght 8 Feet Etc All Complete. (As Market Rate) , Useable Brick (A) Class M-L50 , Useable Brick (B) Class M-100 , Useable Brick(C ) Straiqht Over Brunt , (D) Tiles, Bull Nose Drip Course Brick , Brick Ballast (A) Brick Ballast 40Mm Qauge , Brick Ballast (B) Class-150 Brick Ballast 25Mm Gauge , Brick Ballast (C ) Brick - Bats Of O.B.B./150 Bb , Fiy Ash Brick (Specification/Strength Should Not Be Less Than Bricks - M-{50) 230Mmx1 10Mmx75mm , Aac Block Autoclaved Aerated Concrete Block (Aac Block) Conforming To Ls : 2185 - 2005 (Part-3) Including Loading, Cartage Upto Site, Unloading, Stacking And Including All Levies And Royalties If Any But Excludinq G.S.T , Stone Ballast (Khera Thakur Quarry Bharatpur Rajsthan) 45-90 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 45-63 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 22.4-53 Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 20Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 19Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) Crushed Stone Dust 2.36Mm & Below , Stone Dust , 13.20Mm Guage , 11.20Mm Guage , 6.7Mm Guage And Below , Stone Boulder (From Khera Thakur Quarry) (A) 25-40 Kq , Stone Boulder (From Khera Thakur Quarry) (B) 40-60 Kq , Stone Boulder (From Khera Thakur Quarry) (C) Stone Bricks Dressed , Grit {District Gwalior(Mp) Quarry}(Berja,Chandrapura, Turak Pura,Parsen,Sumerpada Padampur Kheria, Bhileti & Bilara) District Bhind (M.P.)(Pali, Dirman & Piparsana) , (A) 45-63 Mm Guage Stone Ballast. , (B) 22.4-53 Mm Guage Stone Ballast. , (C) 20-40 Mm Guage Stone Ballast. , (D) 20 Mm Guage Stone Ballast. , (E) 19 Mm Guage Stone Ballast. , (F) 16 Mm Guage Stone Ballast. , (G) 13.20 Mm Guage Stone Ballast. , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured Rubber Moulded , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 (Plain) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 16 X6 (Designer) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 18 X6 , Coarse Sand (Excluding Actual Bulkaqe) , Fine Sand (Excludinq Actual Bulkaqe) , (L) Local Sand , Cement (L) Portland Cement (J.P., A.C.C., Birla, J.K.) O.P.C , Cement (Ll) Cement (P.P.C.) , Cement (Lll) White Cement (J.K. Or Birla Brand) , Green Net(Chapter- 1 Sl.No 44) , Tractor Trolley With Driver Including P.O.L. (Chapter-2 Sl.No 25)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 142
Uttar Pradesh View Result →
5.
Educational and Research Institute #11203813 Technical Bid
Tender For Selection Of System Integrator For Supply, Establishment, Operation And Maintenance Of Center Of Excellence On Digitalization Through Simulation At Government College Of Engineering, ,Amravati - Hardware Part , Battery Charge And Discharge Test System , Data Acquisition And Logging System , Thermocouple Rtd For Temperature Measurement , Battery Tester For Internal Resistance Testing , Electric Vehicle Bldc Motor Training System , Bldc Brushless Inner Rotor Brushless Dc Motor Coupled , Battery Characteristics Training System , Pmdc Motor Training System , Power And Transmission System Study Models For Ev Application , Pmsm Motor Coupled With Dc Generator Test Bench Setup , Switched Reluctance Motor Coupled , Pwm Charge Controller Training System , Sectioned Electric Vehicle Twowheeler Chassis , Sectioned Electric Vehicle Fourwheeler Chassis , Battery Resistance Spot Welding Machine , Dc Ac Clamp Meter , Noncontact Type Tacho Meter , Computing Workstations For Ev Design And Simulation , Multibody Dynamics Analysis Research Software Bundle For Ev 10 User , Power Train Gearbox Design Research Software Package , 1D3d Thermal Modelling Bms Modelling Electric Motor Ic Engine , Multiphysics Cae Research Software Package , Nmc Cell Size 18650 , Nmc Cell Size 26650 , Lfp Cell , Smart Bms Training System , Electric Vehicle Scanner , Diy Kits For 20 Students , Advanced Driver Assisting System Adas Training System For Emobility , Ac Ev Charger 10Kw , Dc Fast Charger 20Kw , Multifunction Installation Tester , Electric Vehicle Service Equipment Test Adapter Kit , Battery Tester With Inbuilt Printer , Digital Infrared Thermometer , Digital Multifunction Meter With Vfd Efdetection 3Phase Rotation , Vde Approved Insulated Tool Set For Ev , Electric Vehicle Safety Equipment , Ev Battery Assembly Testing Centre Setup , Ev Battery Pack Cell Equalizer , Regenerative Charging And Braking Training System , Ev Assembly Disassembly Kit , Three Phase Power Clampon Meter With Harmonics Measurement , Digital Insulation Multi Function Meter , Phase Sequence Indicator , Battery Quality Anaylyzer With Data Logger , Hybrid Display Module , Hybrid Trainer Module Motorized , Professional Wall Charts Approx 4 Ft 3 Ft , Professional Lab Layout And Design , Engineering Simulation Software Multiphysics Cae Research Software Includes Preprocessor And Post Processor 10 Users , 3D Cad Package 60 User , Professional Wall Charts , Professional Lab Layout And Design , Video Conferencing Setup , Electromagnetic Em Simulation , Integrated Circuit Ic Design Verification Academic Research Software , Soc Development Board With Software , Emcemi Test Equipment , Spectro Radiometer For Measurement Of The Luminous Flux Spectrum Color , 3D Printer For Prototyping , Professional Wall Charts Approx , Professional Lab Layout And Design , Revolving Chair With Arm Centre Pivot Mechanism , Computer Table , White Board With Stand , Revolving Office Chair With Arm Centre Pivot Mechanism For Faculty , Laboratory Wooden Table , Office Table For Faculty , Major Almirah With Glass Type Doors , Seminar Chairs With Desklet , Executive Office Table , Executive Office Chair , Sofa Set 321 Seater , Teapoycoffee Table , Visitors Chairs With Cushion , Major Almirah , Multi Function All In One Printer For Office And Lab , Necessary Electrification And Networking , Matting Area With Labour Work In Sq Ft , False Ceiling In Sq Ft , Window Sliding Door In Sq Ft , Window Curtains With Fitting In Sq Ft , Gypsum Plaster With Wall Putty In Sq Ft , Wall Coloring In Sq Ft , Air Conditioner 2 Ton , Cctv Camera , Interactive Board , Partitions Cubicles In Sq Ft , Training Support Part , Centre Incharge (Annual Cost) , Lab Operator (Annual Cost) Ev Lab , Faculty Training Ev Lab , Lab Operator (Annual Cost) Simulation Lab , Faculty Training Simulation Lab , Lab Operator (Annual Cost) Esdm Lab , Faculty Training Esdm Lab
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Maharashtra View Result →
6.
Drinking Water Supply and Sanitation #11202616 Technical Bid
Tender for Inspection Of Tubewell With Geo Scanning Borehole Camera With Display And Data Recorder To Find Out The Fault And Submission Of Suggestions Regarding Rectification Of Same To Obtain The Sand Free Water At Site Including Transportation, Lodging, And Boarding. Detailed Analysis With Videography And Submission Of Report, Video And Also Verifying The Depth/ Position Of Assembly Complete In All Respect To The Satisfaction Of Engineer-In-Charge. , Providing And Fixing Of Cast Iron (C.I.) D Plate Of Size 300Mm Dia X 10Mm Thickness Having Weight 7 Kg To Cover The Top Of Borehole Fastened With Nut And Bolts And Clamp Placed On Its Top For Holding The Pump Set And Gi Pipes Lowered In The Tubewell Complete In All Respect To The Satisfaction Of Engineer-In-Charge. , Labour For Making Filter On 219.10 Mm Dia Erw M.S. Pipe (Isi Marked) With Slot Length 62.50Mm And Slot Width 0.5Mm To 0.75Mm Around The Pipe By Gas Cutter Or Any Suitable Mechanism Including Cost Of All Consumable Items Complete In All Respect To The Satisfaction Of Engineer-In-Charge. , Providing And Fixing Of Reinforced Cement Concrete Ring And Cover Of Suitable Dia. To Avoid Intrusion Of Surface Runoff Of Rainfall Inside The Borehole, Including All Fixtures, Complete In All Respects.. , Providing And Fixing Of 2 I/D Nipple Made Out Of G.I. Pipe Class B And Welded With Flange Having Holes For Fasting With Pipe And Threaded At Other End With 8 Threads In One Inch (25Mm) Complete In All Respect To The Satisfaction Of Engineer-In-Charge. , Providing And Fixing Of Odex Casing Shoe Of Proper Size And Isi Make Complete In All Respect. , Providing And Fixing / Lowering 7 (180 Mm) Dia M. S Pipe Of Thickness 6.4Mm Of 6 Meter Long Marked Is 4270 As Required For Covering Loose Formation Of Soil During Drilling Process Including Enlarging The Existing Drilling Size At Any Depth To Cover The Loose Formation Of Bore Complete In All Respect , Drilling Of 300 Mm Dia Bore By Dth For Drilling According To Isi Specification No. 2800-1991 (Part-1) As Amended Upto Date And Modified To Extent Of The Specification Attached With This Schedule Of Items Of Work In All Kinds Of Soils 190Mm Dia Bore By Dth In Hard Rocky Strata Including The Cost Of All Consumable Store, Fuel, Oil, Soil Stabilizing Material And Transportation Of Rig And Other Accessories To The Site Of Proposed Bore And Back Complete In The Satisfaction Of The Engineer-In-Charge. , Resistivity Survey With Deep Penetration, Generator Operated, D.C. Resistivity Meter To Know The Type Of Sub Surface Strata At Different Depths. Quantity Of Water Likely To Be Available And Depth Of The Tubewell To Be Installed To Obtain Fresh Water In Required Quantity Including Transportation Of Equipments And Manpower, Submission Of Hard Copy Of Resistivity Survey With Relevant Technical Data Complete In All Respect To The Satisfaction Of Engineer-In-Charge. , Providing Clay Seal Of Thickness 4.0Mm Or Above Consisting Of Balls Of Local Lay Or Bentonite Mud To Be Placed In The Annular Space Around The Assembly The Clay Seal Should Be Provided At A Level Of Minimum 25.00M Above The Top Most Screens Depending On The Logging Result. , Providing And Fixing M.S Base Plate Of Thickness 10 Mm And Weight Upto 7 Kg To 10 Kg Complete In All Respect To The Satisfaction Of The Engineer-In-Charge. , Development Of Tubewell By Over-Pumping Unit Having Suitable Submersible Pump For Development Of Tubewell To Ensure Sand Free Discharge. All The Equipment Including Pol And Labour Required For Carrying Out Pumping Tests But Not Limited To The Following Shall Be Arranged By The Contractor At His Own Cost Complete In All Respect To The Satisfaction Of Engineer-In-Charge: I) A Suitable Pump And Prime Mover (Since Power Is Not Available At The Well Site). Ii) Measuring Devices For Time, Discharge And V-Notch Orifice Method Water Level Recorder (Digital Water Meter Recorder/ Steel Tape Engraved). Iii) The Contractor Shall Collected Water Sample In The Presence Of Sde/Je. This Water Samples Should Be Handed Over To Phed For Further Chemical Analysis In Public Health Lab , Providing And Fixing Of G.I Clamp 50Mm Wide And 10Mm Thick Suitable For Holding To 50Mm G.I Pipe Class B And Pumping Machinery Complete In All Respect To The Satisfaction Of Engineer-In-Charge. , Providing And Fixing Of 2 I/D Delivery Pipe Class B Isi Marked Of Approved Make Complete In All Respect To The Satisfaction Of Engineer-In-Charge. , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
7.
Housing Urban and Rular Development #11162283 AOC
Providing the manpower for electrical preventive and breakdown maintenance Day to day operation & maintenance of entire electrical installations including Sub-Station, compound lighting, DG operation, dusting and cleaning of fire detection sensors and others parts, operationof liftsetc at the Technician Studio, Kolkata-700033for the period of 12 months.- 1 Day to day operation & maintenance of entire electrical installations including Sub-Station, compound lighting, DG operation, dusting and cleaning of fire detection sensors and others parts, operationof liftsetc at the Technician Studio, Kolkata-700033 2 Skill Electrician: 03 Nos per day 3 Semi-Skill Electrician: 03 Nos per day 4 Un-Skill Electrician: 02 Nos. per day 5 Semi-Skill (Lift Operatror cum Attendent): 02 Nos. per day 6 SCOPE OF WORK:-1. The Scope of maintenance of electrical installation includes Routine, Preventive and Corrective Maintenance of L.T. Distribution lines to each floor of all the buildings/ blocks, entire wirings, BDB, PDB, VTPN, LT panels, Feeder Pillar Box, power & distribution cables, fittings & fixtures, Switch Boards, Power and Computer Points, Power outlet of all sorts of Air-conditioning Systems,resetting/ Switching off of Fire detection system during normal operation/ malfunctioning etc., Operation, configuration & repair / replacement of Timers for AC / Compound light, Compound Lighting including high mast, all glow sign and metal sign boards in the campus, Electrical Installations/ distribution up to Switch Board/ Panel of Lift Machine Room & Pump Room and / or Kiosk of Pump for Water Supply system, in the premises of above mentioned site. 7 2. Cleaning & checking of all the fittings & fixtures, Panels, TPN & SPN DBs, SFUs & other Electrical Installations, as well as the Compound Light installations in a regular interval to keep them in a tip-top condition at the cost of the agency and the same must be recorded in log book.3. The checking & repairing of the different types of light fittings, ceiling fans, exhaust fans etc. has to be done by the agency at his own cost (except rewinding of ceiling fans and exhaust fans) including dismantling and re-fixing of the same. (Major materials to be supplied by department). Especially, all the ceiling fans of entire worksite are to be inspected, at least once in 3(three) Months, in respect of Split Pin, Jam nut etc. to prevent unwanted falling of Ceiling Fans, failing which responsibility will be fixed up upon the agency. Split Pin, once taken out from the installation should not be re-used under any circumstances. Required number of Split Pin and Jam nut should be provided by the agency at their own cost. Building wise Fan register should be maintained as per Performa provided by the department, wherein each and every details of checking, replacement of spares, repairing etc. should be recorded against individual fan and every record should be signed by the attending Electrician / responsible person of the agency, duly countersigned by the concerned J.E. and A.E. 8 4. Measuring of various electrical parameters e.g. Current, Voltage, Temperature of different L.T. panel board, BDBs, Main switches etc., test of Insulation Resistance, Earth Resistance etc. are to be carried out every month and test results are to be recorded in Log book (preventive maintenance). Thermal Imaging Scanner should be used for measuring temperature of electrical equipment regularly to find out any abnormalities and printout of thermal image with date and time stamp should be provided to the concerned J.E. and A.E. In case, any abnormal reading is noticed, the same should be rectified/set right immediately by taking prompt, appropriate & effective measures/actions in consultation with concerned AE&JE. Thermal image should also be taken after rectification. The engaged agency will supervision overall maintenance works and examine Logbooks for any abnormality and sign the Logbook accordingly5. Switching On/Off of the common service lighting e.g. compound, corridors, staircases etc. and AC machines, Light, Fan etc in closed room like Library, Store, OPD, OT or these are not run beyond Office hours or off day will be the responsibility of the agency. 6.Cleaning of Sub-station rooms,LT Panel rooms,operation of HT switch gear & resetting the protective rekeys in case of any fault occurred will be the responsoibilty by the agency . 9 7. Operation of DG sets & checking and maintenance of AMF panel, Checking of Battery, checking of fuel level of DG Set, Lubricating oil etc, carrying & pouring of Fuel if necessary and maintaining separate log book for DG Set as per given Proforma. For Operation of DG Sets, experienced and skilled operator should be provided8.Llift operation cum attendent including regular cleaning of lifts etc as per direction of EIC.9. Regular dusting and cleaning of fire detection sensors and others parts including reset of fire alarms. 10 TERMS & CONDITIONS:-1. The agency has to depute manpower as directed by the EIC carrying out the maintenance work smoothly with due regard to the safety.Category of Staff:- i) Skilled Electrician --03 (Three) Nos per day ii) Semi-Skill Electrician--03(Three) Nos. per day iii) Un-Skill Electrician: 02 Nos. per dayiv) Semi-Skill (Lift Operatror cum Attendent): 02 Nos per day 11 2. The Maintenance Personnel, deputed by the agency havingvalid Voter Identity/ Adhaar Card and should possess valid Workman Permit/ License, as mentioned below, issued by Directorate of Electricity, Govt. of West Bengal.Category of Maintenance Personnel Mandatory Requirementa. Skilled Electrician Having Electrical/ Workman Permit i(b), ii & iv issued by Directorate of Electricity, West Bengal.b. Semi-Skilled Electrician Workman Permit i(b) and (ii) issued by Directorate of Electricity, West Bengal.c. Un-skilled Personnel/ Helper Basic knowledge of Electrical works.Also the Superviser of the company should have valid SCC Parts 1,2,3,4,5,6A,7A,7B ,9,11,12. 12 3. Agency must have to submit mandatorily the list of staff mentioning their Name, contact Mobile No., category, along with photo copy Valid Workman Permit, proper identity and address proof etc, in writing to the concerned JE & AE before commencing the work. All the photocopy should be attested and authenticated by the Agency.4) The agency will issue a photo Identity Card, duly signed by the agency and countersigned by the concerned JE / AE to all the Maintenance Staffs deployed including substitutes.They should always carry the said Photo Identity Card while on duty. The agency should also submit one copy of the said Identity Cards to the JE.5) The agency will maintain shift wise attendance register at call center to record the attendance of the staffs on duty which will be authenticated/ verified by the concerned Junior Engineer/ Officer- in-charge. 13 6) The agency shall have to prepare a Duty Roster of the Maintenance Staffs at the beginning of every month, or as directed from time to time. A copy of the said Duty Roster, duly signed by all staffs, should be submitted to the concerned JE and one copy should be available at the call centre.7)The agency will have to provide proper uniform for his maintenance staff at his own cost and clour of the dress will be decided by the EIC. No staff will be allowed for performing duty without proper uniform. 8) The agency, and all the electricians deputed at worksite must have Mobile Nos. and the same should be intimated to the E.I.C., A.E. & J.E concerned, in writing. The telephone call should be responded without delay. 14 9) The agency has to provide one GPS activated smart phone dedicated for call center. The cost of the handset and running cost i.e. phone bills have to be borne by the agency. No claim of payment against any telephone bill will be entertained by this department.10) The agency should have a close watch on the attendance of the Maintenance Staffs. In case of absence of any Maintenance Staffs, the agency shall have to arrange for suitable alternative within an Hour, failing which, the charges for that day will be deducted from the bill of the agency on pro-rata basis.The Executive Engineer,Electrical Constrution Division ,P.W.D. reserves the right to terminate the contract in case of absence of Maintenance Staffs for more than three consecutive days, without showing further reason. 15 11) In case of any Accident and or physical illness of the staffs of the agency, while on duty, no claim will be entertained by this department and all responsibilities thereof should be shouldered by the agency only. Minimum wages as per existing Labor Act should be paid to the Electrician(s) and Helper(s)12) The agency shall have to provide 500V Megger, Digital Multi meter, Earth tester and all other requisite tools and tackles sufficient for checking, testing and recording of health of all electrical installations. Other tools & tackles e.g. Crimping Machine, Line Tester, Screw Driver, Pliers, Stripper, Sockets of some common sizes etc. should also be available at site, in sufficient quantities, free of cost, under disposal of their maintenance staff.Deployed employee by the agency should have sufficient knowledge to operate The Thermal imaging Scanner or to be used by the direction of Assistant Engineer/ Junior Engineer.13) The space for sitting accommodation for the staffs of the agency inside worksite premises will be provided by the competent authority. 16 14) All the maintenance staff of the contractor should have proper & constant vigilance and check that, there is no sign of heating-up, burning smell, discoloration or sparking at any of BDBs, panel boards, rising main etc. due to overloading or loose termination. Care should be taken to check any highly unbalance in loading at any point.15) In case of power failure or development of any unfavorable situation the agency will have to communicate with the concerned Power Supply Company authority and extend help or cooperation to said authority in restoration of power supply. Meanwhile the agency will have to operate the switching mechanisms of interconnections among available sources at suitable locations to maintain power supplies at important locations by monitoring and/ or restricting electrical loads in consultation with the concerned Junior Engineers & Assistant Engineer.16) Routine checking and preventive maintenance and breakdown maintenanceof the electrical installations has to be carried out by the agency maintaining a register under signature of respective Junior Engineer and Assistant Engineer with a view to ensure uninterrupted power supply within worksite campus. 17 17) Materials required as replacement during maintenance of electrical installations e.g. Lamps, SFUs, SPNDB, TPNDB, Cables etc. will be supplied by the Department for which requisition of Materials, signed by the authorized representative of the agency, should be submitted to the concerned JE (Electrical) well in advance. A separate material stock register should be maintained by the agency where entries related to Issue, Consumption & present stock position of Materials should be made. However auxiliary items like fuse wires, screws, nuts, bolts, washers, insulating tape, Split pins of Ceiling Fans, dusters etc. will have to be supplied by the agency at his/ their own expense.18) The agency shall have to deposit all dismantled unserviceable materials such as fused lamps, defective condensers, starters, and timers, MCBs etc. to the concerned Section Office or any other locations within worksite premises by the agency by its own laborers / arrangements / tools and tackles as per the direction of the Assistant Engineer/ JE concerned. Fresh materials will be issued against respective defective materials. No materials should be taken out of the maintenance site without the permission and necessary challan of the site-in-charge/JE 18 19) Any major shut down or fault should be brought to the notice of JE/AE immediately in writing and over telephone for further course of action. The agency will also have to attend emergency calls immediately at the site with staff, tools etc. on demand. 19 20) In case of any breakdown caused by cable fault etc., if situation demands the agency will have to restore the power supply temporarily either with the materials available with this department or arranging the same temporarily and safely at his own cost till completion of original restoration work.21) Building wise Log book is to be maintained for Preventive Maintenance & Cleaning and Corrective Maintenance of Electrical equipment except Fan as per direction of E.I.C. Separate Building wise Register is to be maintained for Ceiling Fans. The daily record of the Log book is to be signed by the responsible person and verified & signed by concerned JE & AE and photocopy of the same should be sent to the Executive Engineer concerned through proper channel at the time of submission of bills. The Logbooks should be available at Call center and should be produced on demand. 20 21) The agency should be responsible for any damage in the installation due to mishandling or mal- operation by its staff and shall be liable for rectification / replacement, as the case may be, of the damaged installation/ equipment within time frame to be fixed by concerned A.E., failing which the said rectification/ replacement of affected equipment/ installation would be executed by external agency and the cost thereof would be recovered from the bill and the accused staff should be replaced immediately.22) Bills should be submitted quarterly with the certification of satisfactory performance of the concerned JE and AE. Photocopy of Logbook and Attendance Register should also accompany the Bill. Payment should be made as per PWD norms. 21 23) Any fault of electrical installations starting from LT supply end (except the installations of Power Supply Company) to light, fan, call bell, plug points etc. i.e. LT cables and all sub-panels, distribution boards, main switches, earthing attachments, compound lights etc. has to be detected, attended and restored by the agency by its own man power with the help of the materials(cables, main switches, DBs, wires, HRC fuses etc.) available from this department or as per the terms & conditions of this contract. 24) If any kind of incapability & negligence are noticed in observing all the above-said terms & conditions causing inconveniences to public service, is subject to unilateral penalty, be it detected on the spot or thereafter (even after payment). This Department also reserves the right to deduct the cost from the bills of the contractor on pro-rate basis as determined by the Engineer –In-Charge for any shortfall in observing above T&C. In that case, the above- said contract may be terminated without issuing any notice and Stringent & punishable action may be taken against the contractor. 22 25) The technitian of the agency should capable of Casing -caping /rigid conduit wiring to overcome the emergent situation .25) The contract may be terminated with one months’ notice on either side (both agency and tender awarding authority) . 26) At the time of Bill submission must submit payment acquaintance of staff wages ,ESI & PF in which signature of each staff with revenue stamp is necessary .27) Any upcoming / Ongoing project, which will be completed within stipulated period of Maintenance contract, automatically will come under maintenance contract .28) All the log-books should be available at the call center and to be produced to the Office of the AE/ JE on demand. 29) This Maintenance contract covers all the buildings, blocks, outdoor electrical gadgets within the premises ofTechnician Studio, Kolkata-700033 23 TERMS & CONDITIONS FOR OPERATION OF LIFTS:- 24 1. The agency has to depute manpower as directed by the EIC carrying out the lift operation smoothly with due regard to the safety.Category of Staff:- Semi-Skill (Lift Operatror cum Attendent): 02 Nos. 25 2. Day to day Attendent -cum -operation of passenger lift foras directed by the EIC.3. The lift operator/attendant should have a sound knowledge with valid lift operator license issued by the Licensing Board, Govt. of West Bengal.4. The operator/attendant should be obliging dutiful and polite to all while on duty. In case any irregularities of duty or complain against the operator/attendant if noticed, would be withdrawn forthwith and shall be replaced by new operator.5. The report is to be submitted periodically about the working of lift incl. all safety devices and Governor to the concerned JE/AE. 26 6. Agency must have to produce the list of the staff mentioning their Name, contact Mobile No.in writing with proper identity and address proof & their Valid lift operator license issued by the Licensing Board, Govt. of West Bengal along with photo copy to the concerned JE & AE before commencing the work. This should be treated as mandatory.7. The agency will have to provide proper dress for his staff and color of the dress will be decided by this department. No staff will be allowed for performing duty without proper dress.8. The agency will issue a photo Identity Card, duly signed by the agency and countersigned by the concerned JE / AE to all the operation Staffs deployed including substitutes. They should always carry the said Photo Identity Card while on duty. The agency should also submit one copy of the said Identity Cards to the JE 27 9. The agency shall have to prepare a Duty Roster of the operation Staff at the beginning of every month, or as directed from time to time. A copy of the said Duty Roster, duly signed by all staffs, should be submitted to the concerned JE.10. The agency must have separate contact telephone numbers with Mobile Nos. for his office and Supervisor deputed at worksite so that the agency may be communicated in case of any urgency and the same should be intimated to the E.I.C., A.E. & J.E concerned, in writing. The telephone call should be responded without delay.11. The lift enclosure to be kept clean (not sweepers works) regularly by the operator 28 12. The operational work of the lift is to be supervised directly under the supervision of technical staff of the contractors under the direct control of JE/AE concerned. The contractor shall be responsible for any damage to the lift due to mishandling; loss will be recovered from the contractors bill as per direction of EIC.13. The Log Book recording regarding functioning and breakdown of the lift is to be maintained at site by the contractor under supervisions of JE concerned. If any kind of trouble arises, it should be brought to the notice of JE, AE concerned immediately. The JE/AE would put their signature on log book making note on performance. 29 14. In case of any absence of operator, the lift is to be made operative within 2 hours by placing the new operator. In case of absence prorate deduction will be made from the contractors bill and the contract may be terminated if it exceeds 3 (three) days. In this respect Executive Engineer’s decision will be final.15. This department would not be held responsibility for any accident of the liftman on duty for any reasons. The contractor or their lift operators on duty would not claim any compensation in any shape from this department for such accident. 30 16. The Executive Engineer,Electrical ConstructionDivision, P.W.Dte. would have sole authority to cancel the contract without assigning any reason with a notice of one month only.17. Any conditional quotation offered would not be accepted.18. Any quotation offered with price variation clause would not be accepted.19. The payment will be made monthly/quarterly on submission of bill in triplicate by the agency with satisfactory report regarding performance by the concerned JE/AE. Copy of log book has to be enclosed with the bill. 31 20. Persons entrusted by the agency for operation of lift should wear photo Identity Card during duty hours.21. Documentary evidence in support of payment of minimum wages as per Labour Act to be produced to the Principal Employer i.e. Executive Engineer, Electrical Construction Division, P.W.Dte. in-charge of works.22. Rescue operation is in the scope of agency in case of exigency arises out of lifts getting stopped in between landing floors with passengers inside cage.23. No claim towards cost of uniform, PPE e.g. Hand Gloves, Mask, Goggles, protective body- ware etc. for the maintenance staffs should be entertained by this department. However, if any such equipment/ dress is available from the Hospital Authority for their statutory requirement, the same would be provided. BUT IN NO CASE IT SHOULD BE ENTERTAINED AS MANDATORY CLAIM.24.At the time of Bill submission must submit payment acquaintance of staff wages ,ESI & PF in which signature of each staff with revenue stamp is necessary .
Contract Date: Mar 09, 2026 Contract Value : 14.46 Lakh
Government Departments No of Bidders 4
West Bengal View Result →
8.
Educational and Research Institute #11106502 Technical Bid
axiom dual lat pulldown/low row with luxury trim and double stitched upholstery ph-oplr the axiom series lat pulldown/low row accommodates two exercises that target the entire back and rear shoulder muscle groups. the clean, inviting look is appealing to all exercisers. frame • fully welded 11-gauge steel frames • electrostatic powder coat finish for maximum durability tower • consistent low profile 53” (135 cm) tower • full front (or optional rear only) weight stack shrouds adjustments • visible, color contrasting, yellow adjustment handles. • latex free rubber over molded adjustment handles. weight plates • solid steel 15 lb (7.5 kg) weight plates • push / pull increment weight: 7.5 lbs (3.75 kg) • top weight plate is fitted with self-lubricated bushings • magnetic weight selector pin locks into place biomechanics • work-arm movements that correctly align with user joint movements, provide a natural, comfortable feel throughout the entire range of motion. • variable cams & machine design replicate the body’s natural strength profile instructional placards • qr coded / nfc chipped placards pictorially illustrate the muscles trained, proper machine set up & use, for easy to follow instructions regardless of language. size (l x w x h): 91” x 50” x 85” metric (cm): 231 x 127 x 216 recommended live area (l x w x h): 115” x 86” x 97” metric (cm): 292 x 218 x 246 weight: 452 lbs (205 kg) *weight stack (includes increment weight): 202.5 lbs (101.25 kg) max user weight: 300 lbs (136 kg) key features: • accommodates two exercises that target the entire back and rear shoulder muscle groups • comes standard with lat pulldown bar and neutral grip row handle • foot pegs provide additional user stability during row • angled thigh pads stabilize users without the need of an additional adjustment frame colour: standard colour upholstery colour: standard colour working arm colour: standard colour frame , hammer strength select standing calf hs-sc the hammer strength select standing calf is a fundamental part of the strength training progression. nine pad height positions accommodate all users, and contoured non-slip foot plates allow users’ ankles to move in a full range-of-motion. the 22 pieces in the hammer strength select line provide an inviting introduction to hammer strength equipment. • dimensions (l x w x h): 58 in x 45 in x 71.5 in (148 cm x 115 cm x 182 cm) • weight: 680 lb (309 kg) • weight stack weight in kgs: 195 frame colour: standard colour upholstery colour: standard colour working arm colour: standard colour frame , hammer strength plate loaded v-squat pl-vsq the plate-loaded v-squat is designed to have a natural squatting motion, while reducing back and knee strain through a curved arc of motion. it also employs a standard counter balance for lower starting resistance. •starting resistance: 54 lbs (24.5 kg) •dimensions (l x w x h): 91 in x 42 in x 81 in (232 cm x 107 cm x 206 cm) •weight: 530 lb (241 kg) frame colour: standard colour upholstery colour: standard colour working arm colour: standard colour frame , signature plate loaded incline press splip the signature series incline press uses horizontal grips to simulate a more traditional bench press, converging movements for a natural forward pressing motion, and iso-lateral movements for equal strength development. signature series plate-loaded enhances any facility and utilizes independent converging and diverging movements for an instinctively natural experience. •dimensions (l x w x h): 50 in x 62 in x 75 in (127 cm x 158 cm x 191 cm) •weight: 297 lb (135 kg) frame colour: standard colour upholstery colour: standard colour working arm colour: standard colour frame , axiom dual leg extension/leg curl with luxury trim and double stitched upholstery ph-oplce a selectorized station that effectively works complimentary leg muscle groups. designed to be intuitive and inviting for exercisers of all abilities. single-pin adjustment allows exercisers to simultaneously adjust seat and back pad roller pads adjust in 4 positions to accommodate varying tibia lengths hand grips provide user with additional stability during movement footprint (l x w x h)56 x 40 x 53 (metric cm: 142 x 102 x 135) recommended live area (l x w x h)98 x 64 x 77 (249 x 163 x 196) weight450 lbs (204 kg) weight stack(includes increment weight)202.5 lbs (101.25 kg) max user weight300 lbs (136 kg) frame colour: standard colour upholstery colour: standard colour working arm colour: standard colour frame , hammer strength plate loaded iso-lateral low row il-lr the plate-loaded iso-lateral low row was blueprinted from human movement. separate weight horns engage independent diverging and converging motions for equal strength development and muscle stimulation variety. it provides a unique path of motion that contrasts with the decline press. dimensions (l x w x h)50 in x 48 in x 66 in (127 cm x 122 cm x 168 cm) frame colour: standard colour upholstery colour: standard colour working arm colour: standard colour frame , signature plate loaded row splrow •dimensions (l x w x h): 55 in x 57 in x 54 in (140 cm x 145 cm x 138 cm) •weight:294 lb (134 kg) frame colour: standard colour upholstery colour: standard colour working arm colour: standard colour frame , axiom dual abdominal/back extension with luxury trim and double stitched upholstery ph-opabba the axiom series abdominal/back extension is a 8 work arm adjustments allow users a variety of start positions frame • fully welded 11-gauge steel frames • electrostatic powder coat finish for maximum durability tower • consistent low profile 53” (135 cm) tower • full front (or optional rear only) weight stack shrouds adjustments • visible, color contrasting, yellow adjustment handles. • latex free rubber over molded adjustment handles. weight plates • solid steel 15 lb (7.5 kg) weight plates • push / pull increment weight: 7.5 lbs (3.75 kg) • top weight plate is fitted with self-lubricated bushings • magnetic weight selector pin locks into place biomechanics • work-arm movements that correctly align with user joint movements, provide a natural, comfortable feel throughout the entire range of motion. • variable cams & machine design replicate the body’s natural strength profile instructional placards • qr coded / nfc chipped placards pictorially illustrate the muscles trained, proper machine set up & use, for easy to follow instructions regardless of language. size (l x w x h): 58” x 45” x 53” metric (cm): 147 x 114 x 135 recommended live area (l x w x h): 94” x 69” x 77” metric (cm): 239 x 175 x 196 weight: 519 lbs (235 kg) *weight stack (includes increment weight): 202.5 lbs (101.25 kg) max user weight: 300 lbs (136 kg) key features: • unique, workarm design allows for easy entry / exit • 8 workarm adjustments allow users a variety of start positions • two foot support positions better accommodate taller and shorter users • lumbar pad properly positions and supports users during exercise frame colour: standard colour upholstery colour: standard colour working arm colour: standard colour frame , life fitness multi adjustable bench ph-lbr-ma (smab) experience precision adjustments, effortless transport, and unrivaled comfort and style with the life fitness multi-adjustable bench. max user weight: 300 lbs (136 kg) max training weight: 500 lbs (227 kg) back adjustments: -10°, 0°, 15°, 30°, 45°, 60°, 70° seat adjustments: 0°, 15°, 30° weight: 110 lbs (50 kg) size: 58” x 29” x 17” (147 x 73 x 43 cm) frame colour: standard colour upholstery colour: standard colour , ramp up olympic junior 5ft bar ramp up olympic junior 5ft bar , ramp up olympic training barbell brs4004 (women) introducing the all new ramp up powerlifting training bar with single powerlifting knurl marks and centre knurling. with its 29mm shaft diameter and exceptional tensile strength, it offers minimal flex and whip, establishing itself as the ultimate workhorse for bench presses, squats, and deadlifts. get ready to revolutionise your training and elevate your performance to unparalleled heights. women bar, 2010mm length 25mm diameter 8 bearings. bar shaft and sleeve by hardened chrome , ramp up ez curl bar brs4007 (black) ramp up ez curl bar brs4007 (black) , ramp up cpu grips weight plate (brs1007) each plate is derived from heavy-duty iron with a solid, high-grade, low-bounce rubber cover surrounding the parameter. product type: regular cpu weight plate each weight features grip holes to provide a secure grip during use. the coating ensures a durable, reliable weight that will last through grueling workouts & the raised numbers help to easily identify weight sizes. weight plates can be used to perform muscle strengthening exercises and endurance training, and to increase flexibility and balance. a single weight plate can also be used for warm-up exercises.  ramp up cpu grips weight plate 5 kg (brs1007) - 4 nos , ramp up cpu grips weight plate (brs1007) each plate is derived from heavy-duty iron with a solid, high-grade, low-bounce rubber cover surrounding the parameter. product type: regular cpu weight plate each weight features grip holes to provide a secure grip during use. the coating ensures a durable, reliable weight that will last through grueling workouts & the raised numbers help to easily identify weight sizes. weight plates can be used to perform muscle strengthening exercises and endurance training, and to increase flexibility and balance. a single weight plate can also be used for warm-up exercises. , ramp up cpu grips weight plate (bmrs1007) each plate is derived from heavy-duty iron with a solid, high-grade, low-bounce rubber cover surrounding the parameter. product type: regular cpu weight plate each weight features grip holes to provide a secure grip during use. the coating ensures a durable, reliable weight that will last through grueling workouts & the raised numbers help to easily identify weight sizes. weight plates can be used to perform muscle strengthening exercises and endurance training, and to increase flexibility and balance. a single weight plate can also be used for warm-up exercises.  ramp up cpu grips weight plate 15 kg (brs1007) - 4 nos , ramp up cpu grips weight plate (brs1007) each plate is derived from heavy-duty iron with a solid, high-grade, low-bounce rubber cover surrounding the parameter. product type: regular cpu weight plate each weight features grip holes to provide a secure grip during use. the coating ensures a durable, reliable weight that will last through grueling workouts & the raised numbers help to easily identify weight sizes. weight plates can be used to perform muscle strengthening exercises and endurance training, and to increase flexibility and balance. a single weight plate can also be used for warm-up exercises.  ramp up cpu grips weight plate 20 kg (brs1007) - 4 nos , axiom dual multi press with luxury trim and double stitched upholstery ph-opmp the axiom series multi press is a triple-functioning design allows for chest press, incline press and shoulder press movements in a natural body position frame • fully welded 11-gauge steel frames • electrostatic powder coat finish for maximum durability tower • consistent low profile 53” (135 cm) tower • full front (or optional rear only) weight stack shrouds adjustments • visible, color contrasting, yellow adjustment handles. • latex free rubber over molded adjustment handles. weight plates • solid steel 15 lb (7.5 kg) weight plates • push / pull increment weight: 7.5 lbs (3.75 kg) • top weight plate is fitted with self-lubricated bushings • magnetic weight selector pin locks into place biomechanics • work-arm movements that correctly align with user joint movements, provide a natural, comfortable feel throughout the entire range of motion. • variable cams & machine design replicate the body’s natural strength profile instructional placards-------------• qr coded / nfc chipped placards pictorially illustrate the muscles trained, proper machine set up & use, for easy to follow instructions regardless of language. size (l x w x h): 68” x 54” x 62” metric (cm): 173 x 137 x 157 recommended live area (l x w x h): 92” x 78” x 86” metric (cm): 234 x 198 x 218 weight: 539 lbs (245 kg) *weight stack (includes increment weight): 202.5 lbs (101.25 kg) max user weight: 300 lbs (136 kg) key features: • triple-functioning design allows for chest press, incline press and shoulder press movements in a natural body position • a single-pin, gas-assisted mechanism allows for easy, light-weight seat and back pad position adjustments simultaneously for the different exercises. • work arm adjusts in 7 positions for multiple pressing angles to accommodate users size and preference. • multiple grip locations accommodate for different user sizes frame colour: standard colour upholstery colour: standard colour working arm colour: standard colour frame , life fitness cable motion dual adjustable pulley 2:1 - op-dap this multi-exercise machine offers nearly limitless strength training options. the axiom series dual adjustable pulley is a centerpiece for individual workouts, personal training sessions, and small group training. the inviting design with center positioned weight stacks has an open feel and narrow footprint to optimize valuable floor space. the axiom series dual adjustable pulley features an ergonomic pull-up bar that offers several grip positions, and 90 of cable that allows for a wide range of user-defined movements and strength training possibilities. the axiom series dual adjustable pulley includes: one pair of long adjustable handles, one ankle strap and a triceps rope. cable & pulleys • 7 x 19 strand construction, lubricated, nylon-coated cables. • 4.5-inch diameter fiberglass-impregnated nylon pulleys with sealed ball bearings. biomechanics • work-arm movements that correctly align with user joint movements, provide a natural, comfortable feel throughout the entire range of motion. • variable cams & machine design replicate the body’s natural strength profile size (d x w x h): 55” x 56” x 84” metric (cm): 140 x 142 x 213 recommended live area (d x w): 109” x 184” x 102” metric (cm): 277 x 467 x 259 weight: 718 lbs (326 kg) weight stack: standard: 2 – 165 lb (2 – 75 kg) stacks resistance ratio: 1:2 effective user resistance: key features: • 90” (228 cm) of cable travel to accommodate full body movements • ergonomic pull-up bar with neutral, chin up, and pull up grip positions • optimized weight stack position to minimize product width without sacrificing function • accessories included: one pair of long adjustable handles, one ankle strap and one triceps rope frame colour: standard colour upholstery colour: standard colour , life fitness sl powermill climber w apple watch connect - black onyx premium inpmsl the integrity sl console offers an intuitive cardio experience combined with a level of digital connection to fitness apps and wearables that exercisers have come to expect. connects to apple watch® wi-fi, ant+, and nfc compatibility 17 total workouts. elevation goal workouts let the exerciser take their mind off of the burn and allow them climb as high as they can. bluetooth® connection to heart rate straps, headphones and mobile devices an ac motor provides an extremely wide range of speeds. from 12 – 185 steps per minute, the motor’ offers options to all exercisers, whether they’re engaging in reconditioning or hiit workouts. accessory holder integrated smartphone accessory tray with removable cup holders transport wheels four wheels for easy mobility step space 205 sq. in. (0.132 sq. m) step width 20.75 (53 cm) step depth 9.875 (25 cm) step height 7.5 (19.05 cm) step-up height 10.5” (25.4 cm) handlebar design bullhorn resistance technology - drive system surestep system technology, 4.0hp motor/motor controller assembled dimensions 55.9 x 32.8 x 82.3 (143 x 84 x 210 cm) max user weight 400 lbs (181 kg) unit weight 473lbs (215kg) ceiling height required 9 (2.7 m) one floor climbed 16.25 steps safety dual braking system, & recovery modespm 12-185 resistance level 26 (0-25) entry / exit (auto-stop function) dual step-assist & auto-detect feature  slp-cnsl-enm-01 powermill sl console - 1 nos  inpmsl - (base - black onyx) - 1 nos , life fitness treadmill + sl console with apple watch connect - black onyx premium int-sl deck type dx3™ running surface width 22 (56 cm) running surface length 60 (152 cm) motor 4hp (8.0hp peak) ac motor------------------bluetooth®, ant+ and nfc work to provide connection to wearables, headphones, heart rate straps and more. this advanced console technology allows exercisers to workout the way the want. 22 total workouts. highlights include high-intensity and endurance intensity to help runners improve speed and endurance. exercisers can also challenge themselves with eight different fitness tests, including those used by the army, navy, marines and air force.  ph-intdsl-m-ecb (base - black onyx) - 1 nos  slt-cnsl-enm-01 - sl tread led console english metric - 1 nos  int-sl-blkhf-14 - 1 nos  intde-allhx-02 - (black base) - 1 nos  intde-basekit-5102 - 1 nos speed range 0.5 – 14mph (0.8 – 23 km/h) in 0.1 increments step-up height 8 (20 cm) incline 15% max user weight 400lbs (181 kg) length 82 (208 cm) width 36 (91 cm) height 56 (142cm) unit weight 434lbs (197kg) power requirements dedicated 120 volts/20 amp circuit (voltage may vary outside u.s.) life fitness integrity sl console the integrity sl console offers an intuitive cardio experience combined with a level of digital connection to fitness apps and wearables that exercisers have come to expect. get on and go functionality large led display connects to apple watch® the value of connection , life fitness upright bike + sl console w apple watch connect - aspc sl a comfortable cardio option for exercisers of all abilities. the aspire upright exercise bike has a streamlined design that efficiently pairs effective workouts with smart functionality. rooted in decades of proven durability. the generator drive system with poly-v belt resistance requires limited maintenance and also offers a smooth, quiet operation. large led display 17 to 22 workouts (depending upon base type) bluetooth® connection to heart rate straps, headphones and mobile devices wi-fi, ant+, and nfc compatibility connects to apple watch® step-over height - 21.14 (536.9 mm) max user weight- 400 lb (182 kg) drive system- generator drive system with 8-ribbed poly-v belt resistance system resistance levels - 26 resistance type - hybrid eddy current brake with brushless internal generator for low drag and high power capability belt drive - single stage drive with self-tensioning idlers for minimal mechanical drag and low maintenance dimensions - length 41.5 (105cm), width 24.5 (62cm), height 54.5 (138cm)  aspc-sl-cgcxn-12 - aspire upright bike sl base - 1 nos  slxb-cnsl-enm-01 sl bike/ct console - 1 nos , ramp up cpu dumbbell (brs2002) round urethane dumbbells are the epitome of durability, utility and aesthetics. you won’t have to worry about scratches after use and the irritating rubbery odor. manufactured with solid steel heads, surrounded by a thick, shock absorbent and an impact-resistant layer of urethane, these easy-rolling round dumbbells are recommended for fitness facilities where heavy usage takes place.  ramp up cpu dumbbell 15 kg - 1 pair  ramp up cpu dumbbell 20 kg - 1 pair  ramp up cpu dumbbell 22.5 kg - 1 pair  ramp up cpu dumbbell 25 kg - 1 pair  ramp up cpu dumbbell 27.5 kg - 1 pair  ramp up cpu dumbbell 30 kg - 1 pair  ramp up cpu dumbbell 32.5 kg - 1 pair  ramp up cpu dumbbell 35 kg - 1 pair  ramp up cpu dumbbell 37.5 kg - 1 pair  ramp up cpu dumbbell 40 kg - 1 pair  ramp up cpu dumbbell 42.5 kg - 1 pair  ramp up cpu dumbbell 45 kg - 1 pair , axiom dual lat pulldown/low row with luxury trim and double stitched upholstery ph-oplr the axiom series lat pulldown/low row accommodates two exercises that target the entire back and rear shoulder muscle groups. the clean, inviting look is appealing to all exercisers. frame • fully welded 11-gauge steel frames • electrostatic powder coat finish for maximum durability tower • consistent low profile 53” (135 cm) tower • full front (or optional rear only) weight stack shrouds adjustments • visible, color contrasting, yellow adjustment handles. • latex free rubber over molded adjustment handles. weight plates • solid steel 15 lb (7.5 kg) weight plates • push / pull increment weight: 7.5 lbs (3.75 kg) • top weight plate is fitted with self-lubricated bushings • magnetic weight selector pin locks into place biomechanics • work-arm movements that correctly align with user joint movements, provide a natural, comfortable feel throughout the entire range of motion. • variable cams & machine design replicate the body’s natural strength profile instructional placards • qr coded / nfc chipped placards pictorially illustrate the muscles trained, proper machine set up & use, for easy to follow instructions regardless of language. size (l x w x h): 91” x 50” x 85” metric (cm): 231 x 127 x 216 recommended live area (l x w x h): 115” x 86” x 97” metric (cm): 292 x 218 x 246 weight: 452 lbs (205 kg) *weight stack (includes increment weight): 202.5 lbs (101.25 kg) max user weight: 300 lbs (136 kg) key features: • accommodates two exercises that target the entire back and rear shoulder muscle groups • comes standard with lat pulldown bar and neutral grip row handle • foot pegs provide additional user stability during row • angled thigh pads stabilize users without the need of an additional adjustment frame colour: standard colour upholstery colour: standard colour working arm colour: standard colour frame , hammer strength select standing calf hs-sc the hammer strength select standing calf is a fundamental part of the strength training progression. nine pad height positions accommodate all users, and contoured non-slip foot plates allow users’ ankles to move in a full range-of-motion. the 22 pieces in the hammer strength select line provide an inviting introduction to hammer strength equipment. • dimensions (l x w x h): 58 in x 45 in x 71.5 in (148 cm x 115 cm x 182 cm) • weight: 680 lb (309 kg) • weight stack weight in kgs: 195 frame colour: standard colour upholstery colour: standard colour working arm colour: standard colour frame , hammer strength plate loaded v-squat pl-vsq the plate-loaded v-squat is designed to have a natural squatting motion, while reducing back and knee strain through a curved arc of motion. it also employs a standard counter balance for lower starting resistance. •starting resistance: 54 lbs (24.5 kg) •dimensions (l x w x h): 91 in x 42 in x 81 in (232 cm x 107 cm x 206 cm) •weight: 530 lb (241 kg) frame colour: standard colour upholstery colour: standard colour working arm colour: standard colour frame , signature plate loaded incline press splip the signature series incline press uses horizontal grips to simulate a more traditional bench press, converging movements for a natural forward pressing motion, and iso-lateral movements for equal strength development. signature series plate-loaded enhances any facility and utilizes independent converging and diverging movements for an instinctively natural experience. •dimensions (l x w x h): 50 in x 62 in x 75 in (127 cm x 158 cm x 191 cm) •weight: 297 lb (135 kg) frame colour: standard colour upholstery colour: standard colour working arm colour: standard colour frame , axiom dual leg extension/leg curl with luxury trim and double stitched upholstery ph-oplce a selectorized station that effectively works complimentary leg muscle groups. designed to be intuitive and inviting for exercisers of all abilities. single-pin adjustment allows exercisers to simultaneously adjust seat and back pad roller pads adjust in 4 positions to accommodate varying tibia lengths hand grips provide user with additional stability during movement footprint (l x w x h)56 x 40 x 53 (metric cm: 142 x 102 x 135) recommended live area (l x w x h)98 x 64 x 77 (249 x 163 x 196) weight450 lbs (204 kg) weight stack(includes increment weight)202.5 lbs (101.25 kg) max user weight300 lbs (136 kg) frame colour: standard colour upholstery colour: standard colour working arm colour: standard colour frame , hammer strength plate loaded iso-lateral low row il-lr the plate-loaded iso-lateral low row was blueprinted from human movement. separate weight horns engage independent diverging and converging motions for equal strength development and muscle stimulation variety. it provides a unique path of motion that contrasts with the decline press. dimensions (l x w x h)50 in x 48 in x 66 in (127 cm x 122 cm x 168 cm) frame colour: standard colour upholstery colour: standard colour working arm colour: standard colour frame , signature plate loaded row splrow •dimensions (l x w x h): 55 in x 57 in x 54 in (140 cm x 145 cm x 138 cm) •weight:294 lb (134 kg) frame colour: standard colour upholstery colour: standard colour working arm colour: standard colour frame , axiom dual abdominal/back extension with luxury trim and double stitched upholstery ph-opabba the axiom series abdominal/back extension is a 8 work arm adjustments allow users a variety of start positions frame • fully welded 11-gauge steel frames • electrostatic powder coat finish for maximum durability tower • consistent low profile 53” (135 cm) tower • full front (or optional rear only) weight stack shrouds adjustments • visible, color contrasting, yellow adjustment handles. • latex free rubber over molded adjustment handles. weight plates • solid steel 15 lb (7.5 kg) weight plates • push / pull increment weight: 7.5 lbs (3.75 kg) • top weight plate is fitted with self-lubricated bushings • magnetic weight selector pin locks into place biomechanics • work-arm movements that correctly align with user joint movements, provide a natural, comfortable feel throughout the entire range of motion. • variable cams & machine design replicate the body’s natural strength profile instructional placards • qr coded / nfc chipped placards pictorially illustrate the muscles trained, proper machine set up & use, for easy to follow instructions regardless of language. size (l x w x h): 58” x 45” x 53” metric (cm): 147 x 114 x 135 recommended live area (l x w x h): 94” x 69” x 77” metric (cm): 239 x 175 x 196 weight: 519 lbs (235 kg) *weight stack (includes increment weight): 202.5 lbs (101.25 kg) max user weight: 300 lbs (136 kg) key features: • unique, workarm design allows for easy entry / exit • 8 workarm adjustments allow users a variety of start positions • two foot support positions better accommodate taller and shorter users • lumbar pad properly positions and supports users during exercise frame colour: standard colour upholstery colour: standard colour working arm colour: standard colour frame , life fitness multi adjustable bench ph-lbr-ma (smab) experience precision adjustments, effortless transport, and unrivaled comfort and style with the life fitness multi-adjustable bench. max user weight: 300 lbs (136 kg) max training weight: 500 lbs (227 kg) back adjustments: -10°, 0°, 15°, 30°, 45°, 60°, 70° seat adjustments: 0°, 15°, 30° weight: 110 lbs (50 kg) size: 58” x 29” x 17” (147 x 73 x 43 cm) frame colour: standard colour upholstery colour: standard colour , ramp up olympic junior 5ft bar ramp up olympic junior 5ft bar , ramp up olympic training barbell brs4004 (women) introducing the all new ramp up powerlifting training bar with single powerlifting knurl marks and centre knurling. with its 29mm shaft diameter and exceptional tensile strength, it offers minimal flex and whip, establishing itself as the ultimate workhorse for bench presses, squats, and deadlifts. get ready to revolutionise your training and elevate your performance to unparalleled heights. women bar, 2010mm length 25mm diameter 8 bearings. bar shaft and sleeve by hardened chrome , ramp up ez curl bar brs4007 (black) ramp up ez curl bar brs4007 (black) , ramp up cpu grips weight plate (brs1007) each plate is derived from heavy-duty iron with a solid, high-grade, low-bounce rubber cover surrounding the parameter. product type: regular cpu weight plate each weight features grip holes to provide a secure grip during use. the coating ensures a durable, reliable weight that will last through grueling workouts & the raised numbers help to easily identify weight sizes. weight plates can be used to perform muscle strengthening exercises and endurance training, and to increase flexibility and balance. a single weight plate can also be used for warm-up exercises.  ramp up cpu grips weight plate 5 kg (brs1007) - 4 nos , ramp up cpu grips weight plate (brs1007) each plate is derived from heavy-duty iron with a solid, high-grade, low-bounce rubber cover surrounding the parameter. product type: regular cpu weight plate each weight features grip holes to provide a secure grip during use. the coating ensures a durable, reliable weight that will last through grueling workouts & the raised numbers help to easily identify weight sizes. weight plates can be used to perform muscle strengthening exercises and endurance training, and to increase flexibility and balance. a single weight plate can also be used for warm-up exercises. , ramp up cpu grips weight plate (bmrs1007) each plate is derived from heavy-duty iron with a solid, high-grade, low-bounce rubber cover surrounding the parameter. product type: regular cpu weight plate each weight features grip holes to provide a secure grip during use. the coating ensures a durable, reliable weight that will last through grueling workouts & the raised numbers help to easily identify weight sizes. weight plates can be used to perform muscle strengthening exercises and endurance training, and to increase flexibility and balance. a single weight plate can also be used for warm-up exercises.  ramp up cpu grips weight plate 15 kg (brs1007) - 4 nos , ramp up cpu grips weight plate (brs1007) each plate is derived from heavy-duty iron with a solid, high-grade, low-bounce rubber cover surrounding the parameter. product type: regular cpu weight plate each weight features grip holes to provide a secure grip during use. the coating ensures a durable, reliable weight that will last through grueling workouts & the raised numbers help to easily identify weight sizes. weight plates can be used to perform muscle strengthening exercises and endurance training, and to increase flexibility and balance. a single weight plate can also be used for warm-up exercises.  ramp up cpu grips weight plate 20 kg (brs1007) - 4 nos , axiom dual multi press with luxury trim and double stitched upholstery ph-opmp the axiom series multi press is a triple-functioning design allows for chest press, incline press and shoulder press movements in a natural body position frame • fully welded 11-gauge steel frames • electrostatic powder coat finish for maximum durability tower • consistent low profile 53” (135 cm) tower • full front (or optional rear only) weight stack shrouds adjustments • visible, color contrasting, yellow adjustment handles. • latex free rubber over molded adjustment handles. weight plates • solid steel 15 lb (7.5 kg) weight plates • push / pull increment weight: 7.5 lbs (3.75 kg) • top weight plate is fitted with self-lubricated bushings • magnetic weight selector pin locks into place biomechanics • work-arm movements that correctly align with user joint movements, provide a natural, comfortable feel throughout the entire range of motion. • variable cams & machine design replicate the body’s natural strength profile instructional placards-------------• qr coded / nfc chipped placards pictorially illustrate the muscles trained, proper machine set up & use, for easy to follow instructions regardless of language. size (l x w x h): 68” x 54” x 62” metric (cm): 173 x 137 x 157 recommended live area (l x w x h): 92” x 78” x 86” metric (cm): 234 x 198 x 218 weight: 539 lbs (245 kg) *weight stack (includes increment weight): 202.5 lbs (101.25 kg) max user weight: 300 lbs (136 kg) key features: • triple-functioning design allows for chest press, incline press and shoulder press movements in a natural body position • a single-pin, gas-assisted mechanism allows for easy, light-weight seat and back pad position adjustments simultaneously for the different exercises. • work arm adjusts in 7 positions for multiple pressing angles to accommodate users size and preference. • multiple grip locations accommodate for different user sizes frame colour: standard colour upholstery colour: standard colour working arm colour: standard colour frame , life fitness cable motion dual adjustable pulley 2:1 - op-dap this multi-exercise machine offers nearly limitless strength training options. the axiom series dual adjustable pulley is a centerpiece for individual workouts, personal training sessions, and small group training. the inviting design with center positioned weight stacks has an open feel and narrow footprint to optimize valuable floor space. the axiom series dual adjustable pulley features an ergonomic pull-up bar that offers several grip positions, and 90 of cable that allows for a wide range of user-defined movements and strength training possibilities. the axiom series dual adjustable pulley includes: one pair of long adjustable handles, one ankle strap and a triceps rope. cable & pulleys • 7 x 19 strand construction, lubricated, nylon-coated cables. • 4.5-inch diameter fiberglass-impregnated nylon pulleys with sealed ball bearings. biomechanics • work-arm movements that correctly align with user joint movements, provide a natural, comfortable feel throughout the entire range of motion. • variable cams & machine design replicate the body’s natural strength profile size (d x w x h): 55” x 56” x 84” metric (cm): 140 x 142 x 213 recommended live area (d x w): 109” x 184” x 102” metric (cm): 277 x 467 x 259 weight: 718 lbs (326 kg) weight stack: standard: 2 – 165 lb (2 – 75 kg) stacks resistance ratio: 1:2 effective user resistance: key features: • 90” (228 cm) of cable travel to accommodate full body movements • ergonomic pull-up bar with neutral, chin up, and pull up grip positions • optimized weight stack position to minimize product width without sacrificing function • accessories included: one pair of long adjustable handles, one ankle strap and one triceps rope frame colour: standard colour upholstery colour: standard colour , life fitness sl powermill climber w apple watch connect - black onyx premium inpmsl the integrity sl console offers an intuitive cardio experience combined with a level of digital connection to fitness apps and wearables that exercisers have come to expect. connects to apple watch® wi-fi, ant+, and nfc compatibility 17 total workouts. elevation goal workouts let the exerciser take their mind off of the burn and allow them climb as high as they can. bluetooth® connection to heart rate straps, headphones and mobile devices an ac motor provides an extremely wide range of speeds. from 12 – 185 steps per minute, the motor’ offers options to all exercisers, whether they’re engaging in reconditioning or hiit workouts. accessory holder integrated smartphone accessory tray with removable cup holders transport wheels four wheels for easy mobility step space 205 sq. in. (0.132 sq. m) step width 20.75 (53 cm) step depth 9.875 (25 cm) step height 7.5 (19.05 cm) step-up height 10.5” (25.4 cm) handlebar design bullhorn resistance technology - drive system surestep system technology, 4.0hp motor/motor controller assembled dimensions 55.9 x 32.8 x 82.3 (143 x 84 x 210 cm) max user weight 400 lbs (181 kg) unit weight 473lbs (215kg) ceiling height required 9 (2.7 m) one floor climbed 16.25 steps safety dual braking system, & recovery modespm 12-185 resistance level 26 (0-25) entry / exit (auto-stop function) dual step-assist & auto-detect feature  slp-cnsl-enm-01 powermill sl console - 1 nos  inpmsl - (base - black onyx) - 1 nos , life fitness treadmill + sl console with apple watch connect - black onyx premium int-sl deck type dx3™ running surface width 22 (56 cm) running surface length 60 (152 cm) motor 4hp (8.0hp peak) ac motor------------------bluetooth®, ant+ and nfc work to provide connection to wearables, headphones, heart rate straps and more. this advanced console technology allows exercisers to workout the way the want. 22 total workouts. highlights include high-intensity and endurance intensity to help runners improve speed and endurance. exercisers can also challenge themselves with eight different fitness tests, including those used by the army, navy, marines and air force.  ph-intdsl-m-ecb (base - black onyx) - 1 nos  slt-cnsl-enm-01 - sl tread led console english metric - 1 nos  int-sl-blkhf-14 - 1 nos  intde-allhx-02 - (black base) - 1 nos  intde-basekit-5102 - 1 nos speed range 0.5 – 14mph (0.8 – 23 km/h) in 0.1 increments step-up height 8 (20 cm) incline 15% max user weight 400lbs (181 kg) length 82 (208 cm) width 36 (91 cm) height 56 (142cm) unit weight 434lbs (197kg) power requirements dedicated 120 volts/20 amp circuit (voltage may vary outside u.s.) life fitness integrity sl console the integrity sl console offers an intuitive cardio experience combined with a level of digital connection to fitness apps and wearables that exercisers have come to expect. get on and go functionality large led display connects to apple watch® the value of connection , life fitness upright bike + sl console w apple watch connect - aspc sl a comfortable cardio option for exercisers of all abilities. the aspire upright exercise bike has a streamlined design that efficiently pairs effective workouts with smart functionality. rooted in decades of proven durability. the generator drive system with poly-v belt resistance requires limited maintenance and also offers a smooth, quiet operation. large led display 17 to 22 workouts (depending upon base type) bluetooth® connection to heart rate straps, headphones and mobile devices wi-fi, ant+, and nfc compatibility connects to apple watch® step-over height - 21.14 (536.9 mm) max user weight- 400 lb (182 kg) drive system- generator drive system with 8-ribbed poly-v belt resistance system resistance levels - 26 resistance type - hybrid eddy current brake with brushless internal generator for low drag and high power capability belt drive - single stage drive with self-tensioning idlers for minimal mechanical drag and low maintenance dimensions - length 41.5 (105cm), width 24.5 (62cm), height 54.5 (138cm)  aspc-sl-cgcxn-12 - aspire upright bike sl base - 1 nos  slxb-cnsl-enm-01 sl bike/ct console - 1 nos , ramp up cpu dumbbell (brs2002) round urethane dumbbells are the epitome of durability, utility and aesthetics. you won’t have to worry about scratches after use and the irritating rubbery odor. manufactured with solid steel heads, surrounded by a thick, shock absorbent and an impact-resistant layer of urethane, these easy-rolling round dumbbells are recommended for fitness facilities where heavy usage takes place.  ramp up cpu dumbbell 15 kg - 1 pair  ramp up cpu dumbbell 20 kg - 1 pair  ramp up cpu dumbbell 22.5 kg - 1 pair  ramp up cpu dumbbell 25 kg - 1 pair  ramp up cpu dumbbell 27.5 kg - 1 pair  ramp up cpu dumbbell 30 kg - 1 pair  ramp up cpu dumbbell 32.5 kg - 1 pair  ramp up cpu dumbbell 35 kg - 1 pair  ramp up cpu dumbbell 37.5 kg - 1 pair  ramp up cpu dumbbell 40 kg - 1 pair  ramp up cpu dumbbell 42.5 kg - 1 pair  ramp up cpu dumbbell 45 kg - 1 pair
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
10.
Public Administrative Department #10787946 Price Bid
Tender For supply of Medical Books 173 Nos , Medical Books For The Central Library Deparment Of Ltmg Hospital Sion , Ian Textbook Of Neurology 2 Vol Set , Peripheral Neuropathy2 Vol Set , Potter & Perrys Essentials Of Nursing Foundation , Ross & Wilson Anatomy & Physiology In Health & Illness , Lewiss Medical Surgical Nursing 2 Vol Set , Nursing Research & Statistics , Text Book Of Obstetrics , Wongs Essentials Of Paediatricnursing South Asia Edition , Blacks Medical Surgical Nursing Clinical Management Of Positive Outcome (Sae) , Management Of Nursing Service & Education , Microelectrode Recording In Movement Disorders Surgery , Dystonia Causes Symptoms And Treatment , Plastic Surgery 6 Vol Set , Greens Operative Hand Surgery 2 Vol Set , Plastic Reconstructive And Aesthetic Surgery 6 Vol Set , The Harriet Lane Handbook Sae John Hopkins Hospital , Iap Textbook Of Paediatrics , Illingworths The Development Of The Infants And Young Child Normal And Abnormal , Nutrition And Child Development , Paediatric Clinical Examination , Paediatric Intensive Care Protocols Of Aiims , Pg Textbook Of Paediatrics 3 Vol Set , Middletons Allergy Principle & Practice 2 Vol Set , Fannaroff And Martins Neonatal Perinatal Medicine 2 Vol Set , Parks Paediatric Cardiology For Practitioners , Perloffs Clinical Recognition Of Congenital Heart Disease , Fuhrman And Zimmermans Paediatric Critical Care , Lanzonskys Manual Of Pediatric Hematology , Atlas And Text Of Hematology 2 Vol Set , Paediatric Gastrointestinal And Liver Disease , Textbook Of Gastrointestinal Radiology 2 Vol Set , Sleisenger And Fordtrans Gastrointestinal And Liver Disease 2 Vol Set , Textbook Of Radiology & Imaging 2 Vol , Ct & Mri Of The Whole Body 2 Vol Set , Diagnostic Ultra Sound 2 Vol Set , Comprehensive Textbook Of Clinical Radiology 6 Vol Set , Youmans And Winn Neurological Surgery 4 Vol Set , Campbell Wash Wein Urology 4 Vol Set , Holcomb Ashcrafts Paediatric Minimally Invasive Surgery , Blumgarts Surgery Of The Liverbiliary Tract And Pancreas 2 Vol Set , Brenner And Rectors The Kidney 2 Vol Set , Comprehensive Clinical Nephrology , Kindey Transplantation: Principles And Practice , Handbook Of Dialysis Therapy , Coughlin And Manns Surgery Of Foot And Ankle 2 Vol Set , Principles And Practice Of Biostatistics , Epidemology And Management For Health Care , Mahajan’S Methods In Biostatistics For Medical Students And Research Workers , Community Medicine With Recent Advances , Iapsm Textbook Of Community Medicine , Exam Preparatory Manual For Undergraduates Community Medicine Psm , Textbook Of Community Medicine , An Introduction To Sociology , Gordis Epidemiology , Jekels Epidemiology Biostatistics Preventive Medicine And Public Health , Research Methodology For Health Professionals Including Proposal Thesis & Article Writingresearch Funding Andplagiarism , Practical Guide Qualitative Researchmethods In Health And Educational Research , Dk Tanejas Health Policies And Programmes In India , Essentials Of Community Medicine Practicals , Community Medicine Practical Manual With Viva , Bailey &Scotts Diagnostic Microbiology , Textbook Of Mycology , Essentials Of Hospital Infections , Cbme Pharmacology Skills Ospe Practical Doap , Rang & Dales Pharmacology , Braddomsphysical Med And Rehabilitation , Essentials Of Orthopaedics For Physiotherapists , Occupational Therapy In Mental Health , Pediatric Intensive Care Protocol , Therapeutic Exercise , Cohens Pathways Of The Pulp Sae , Ingles Endodontics Practice , Medical Emergencies Dentel Office , Text Book Of Oral And Maxillofacial Surgery , Contemporary Fixed Prosthodontics Sae , Anatomical Principles Of Endoscopic Sinus Surgery , Endoscopic Endonasal Surgery Sinyses & Beyond , Textbook Of Laryngology , Post Graduate Ophthalmology 2 Vol Set , Comprehensive Ophthalmology , Ophthalmology , Parsons Diseases Of Eye , Ocular Surface Disease Cornea Conjunctive And Tear Film , Volpes Neurology Of The New Born , Goldsmiths Assisted Ventilation Of The Neonate An Evidence Based Approach To New Born Respiratory Care , Shackelfords Surgery Of The Alimentary Tract 2 Vol Set , Smith & Aitkenheads Textbook Of Anaesthesia , A Practice Of Anaesthesia For Infants And Children , Litmans Basics Of Paediatric Anaesthesia , Smith Paediatric Anaesthesia , Kaplans Cardiac Anaesthesia , Ohs Intensive Care Manual , Principles Of Critical Care , Browns Atlas Of Regional Anaesthesia , Point Of Care Ultrasound , V V Pillay Modern Medical Toxicology , Forensic Medicine & Toxicology By Dr Pc Ignatus , Principles Of Forensic Medicine & Toxicology , Review Of Forensic Medicine And Toxicology , The Developing Human Clinical Embryology Sae , Human Genetics , Netters Atlas Of Human Anatomy , Textbook Of Clinical Neuroanatomy , Textbook Of Anatomy 3 Vol Set With General Anatomy , Atlas Of Anatomy (Sae) , Greys Anatomy For Students International Edition , Greys Anatomy The Anatomical Basis Of Clinical Practice , Abrahams And Mcminns Clinical Atlas Of Human Anatomy , Inderbir Singhs Textbook Of Human Histology , Inderbir Singhs Human Embryology , Larsens Human Embryology , Sontakkestextbook Of Histology , Davidsons Principles And Practice Of Medicine , Kumar And Clarks Clinical Medicine , Manual Of Practical Medicine , Hutchinsons Clinical Methods An Integrated Approach To Clinical Methods , Api Textbook Of Medicine 2 Vol Set , The Ecg Made Easy Intrernational Edition , Lpr Fundamental Of Medicalphysiology 2 Vol Set , Clinical Neurophysiology , Tietz Textbook Of Clinical Chemistry &Molecular Diagnostics , Williams Textbook Of Endocrinology , Bedside Clinics In Surgery , A Manual Of Clinical Surgery With Diagnostic Algorithms , Srbs Manual Of Surgery , Comprehensive Textbook Of Medical Physiology 2 Vol Set , Ghais Textbook Of Practical Physiology , Textbook Of Physiology , Clinical Anatomy 2 Vol Set , Dissection Manual With Regions & Applied Anatomy 3 Vol Set , Textbook Of Biochemistry For Medical Students , Ug Textbook Of Paediatrics , Endoscopic Ultrasound An Introductory Manual & Atlas , Mckee’S Pathology Of The Skin With Clinical Correlation 2 Vol Set , Deep Brain Stimulation And Epilepsy , Pediatric Brain Stimulation: Mapping And Modulating The Development , Deep Brain Stimulation Programming Mechanisms,Principles And Practice , Deep Brain Stimulation: A Casebased Approach , Pediatric Endocrine Disorders , Evidence Based Pediatric Oncology , Childhood Leukaemia , Drugs In Cancer Care , Liver Disease In Children , Walker’S Paediatric Gastrointestinal Disease Physiology, Diagnosis Management , Sherlock’S Disease Of The Biliary System , Schffs Disease Of The Liver , Cotton And William’S Practical Gastrointestinal Endoscopy The Fundamentals , Yamada Atlas Of Gastroenterology , The Kelalis Kings Belman Text Book Of Clinical Paediatric Urology 3 Vol Set , Atlas Of Fetal Surgery , Necrotizing Entrocolitis Oathogenesis Diagnosis And Treatment , Abram’S Urodynamic , Oxford Textbook Of Clinical Nephrology 3 Vol Set , Essentials Of Biostatistics And Research Methodology , Oxford Textbook Of Global Public Health , Oxford Textbook Of Medical Statistics , Research Methodology Methods And Techniques , Survey Methods In Community Medicine:Epidemiological Research, Programme Evaluation, Clinical Trials , Essentials Of Health Economics , Health Economics: An Introduction For Health Professionals , Koneman Colour Atlas Of Textbook Of Microbiology , Roitts Essential Immunology , Kuby Immunology , District Lab.Practice In Tropical Countries (Sae) 2 Vol.Set , Clinical Application Of Mechanical Ventilation , Principles & Practice Of Geriatric Medicine , Textbook Of Assisted Reproductive Techniques 2 Vol Set , Injuries Forensic And Medico Legal Aspects , Forensic Medicine & Toxicology Theory, Oral Practical , J.B.Mukherjee’S Forensic Medicine & Toxicology , Keith Simpson’S Forensic Medicine , Handbook Of Forensic Pathology , Endoscopic Ultrasonography
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 4
Maharashtra View Result →
11.
Railways #10737503 AOC
Supply Of Hydraulic Re-Railing Equipmenthydraulic Re-Railing Equipment,Supply Of Hydraulic Re-Railing Equipment With Concomitant Accessories And Additional Acces Sories (Pump Set With Petrol Engine-1 No, Portable Control Table-1 No, High Pressure Hoses-1 Set And Roller Carriage-1 No) As Per Technical Specification Attached. [ Warranty Period: 24 Months After The Date Of Del Ivery ] ] , Post Warranty Comprehensive Annual Maintenance Charges ( After 2 Years Free Warranty Period ) Firm To Quote Separately Ie Year 1 Tab ( For 3 Rd Year). Year 2 Tab ( For 4 Th Year) , Year 3 Tab ( For 5 Th Year) ,Year 4 Tab ( For 6 Th Year) And Year 5 Tab ( For 7 Th Year) [ Warranty Period: 2 Years, Amc Period: 5 Years, Rate Of Discounting: 10 % ] ] At (Location) Cws/Jtj, Sr Tamil Nadu 1.00 Numbers 3 6507Ns01 Essential Non Stock --- Yes Tpi Agency Inr (G1) Spares (Y) Spares For 2 Years Normal Operation And Maintenance With Price Breakup Of Individual Items As Per Clause 3 Of Part-1 (Annexure-B) [ Warranty Period: 30 Months After The Date Of Delivery ] ] Consignee Cws/Jtj, Sr Tamil Nadu 1.00 Set Inspection Details Stage Inspection Not Required 4 6507Ser1 Essential Non Stock --- Yes Consignee Inr (G1) Services (Y) Cost Of Installation & Commissioning Of Equipment ] At (Location) Cws/Jtj, Sr Tamil Nadu 1.00 Numbers Group G2-Sse/C&W/Art/Bbq Page 1 Of 14 Run Date/Time: 10/07/2025 11:56:48Stores/Southern Rly Tender Document Tender No 16255011 Closing Date/Time 11/08/2025 14:30 1 650700730054 Basic Non Stock --- Yes Tpi Agency Inr (G2) Machine (Y) Supply Of Hydraulic Re-Railing Equipment With Concomitant Accessories And Additional Acces Sories (Pump Set With Petrol Engine-1 No, Portable Control Table-1 No, High Pressure Hoses-1 Set And Roller Carriage-1 No) As Per Technical Specification Attached. [ Warranty Period: 24 Months After The Date Of Del Ivery ] ] Consignee Sse/Bbq, Sr Tamil Nadu 1.00 Set Inspection Details Stage Inspection Not Required 2 6507Ser2 Amc (Y) Non Stock --- Yes Consignee Inr (G2) Post Warranty Comprehensive Annual Maintenance Charges ( After 2 Years Free Warranty Period ) Firm To Quote Separately Ie Year 1 Tab ( For 3 Rd Year). Year 2 Tab ( For 4 Th Year) , Year 3 Tab ( For 5 Th Year) ,Year 4 Tab ( For 6 Th Year) And Year 5 Tab ( For 7 Th Year) [ Warranty Period: 2 Years, Amc Period: 5 Years, Rate Of Discounting: 10 % ] ] At (Location) Sse/Bbq, Sr Tamil Nadu 1.00 Numbers 3 6507Ns01 Essential Non Stock --- Yes Tpi Agency Inr (G2) Spares (Y) Spares For 2Years Normal Operation And Maintenance With Price Breakup Of Individual Items A S Per Clause 3 Of Part-1 (Annexure-B) [ Warranty Period: 30 Months After The Date Of Delivery ] ] Consignee Sse/Bbq, Sr Tamil Nadu 1.00 Set Inspection Details Stage Inspection Not Required 4 6507Ser1 Essential Non Stock --- Yes Consignee Inr (G2) Services (Y) Cost Of Installation & Commissioning Of Equipment ] At (Location) Sse/Bbq, Sr Tamil Nadu 1.00 Numbers 3. T And C F.O.R Description Destination Delivery Period Description Delivery /Completion Rate Of Supply For All Items Commencement : Within 2 Months Of Issue Of Contract, However, Delivery Completion : Within 3 Months Thereafter Period Shall Not Exceed No. Of Days As Mentioned In Delivery Schedule Chart Attached. However, The Delivery Period Indicated Being Tentative, May Vary At The The Time Of Placement Of Order. Payment Terms S.No Description Payment Terms 1 1) 60% Payment: Upon Receipt Of The M&P, Duly Pre-Inspected By A Third -Party Inspection (Tpi) Agency, Receipted At The Site By The Consignee In Good Condition And Submission Of A Joint Receipt Note. 2) 20% Intermediate Payment: After Successful Installation And Commissioning And Submission Of A Joint Commissioning Note. 3) Final 20% Payment: After Commissioning Of The M&P At The Consignees End For A Minimum Period Of 30 Days, Upon Submission Of A 10% Warranty Bank Guarantee And A Proving Test Certificate Statutory Variation Clause Page 2 Of 14 Run Date/Time: 10/07/2025 11:56:48Stores/Southern Rly Tender Document Tender No 16255011 Closing Date/Time 11/08/2025 14:30 S.No Description 1 Statutory Variation In Taxes And Duties, Or Fresh Imposition Of Taxes And Duties By State/ Central Governments In Respect Of The Items Stipulated In The Contract (And Not The Raw Materials Thereof), Within The Original Delivery Period Stipulated In The Contract, Or Last Unconditionally Extended Delivery Period Shall Be To Railways Account. Only Such Variation Shall Be Admissible Which Takes Place After The Submission Of Bid. No Claim On Account Of Statutory Variation In Respect Of Existing Tax/Duty Will Be Accepted Unless The Tenderer Has Clearly Indicated In His OffEr The Rate Of Tax/Duty Considered In His Quoted Rate. No Claim On Account Of Statutory Variation Shall Be Admissible On Account Of Misclassiï¬Cation By The Supplier/ Contractor. Standard Governing Conditions S.No Description 1 The Bidder Agrees To Supply The Tendered Stores At The Rates Quoted By Him In Accordance With The Latest Version Of Irs Conditions Of Contract (Attached As Irs Conditions Of Contract To This Tender Document For Ready Reference) And Southern Railway Tender Conditions (Attached As Sr Tender Conditions To This Tender Document For Ready Reference). 4. Eligibility Conditions Special Eligibility Criteria S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Supply To Be Strictly As Per Speciï¬Cations Normal Applicable To Yes Yes Not Allowed Document Uploaded With This Tender. All Bidders 2 Please Refer Attached Document Titled Normal Applicable To Yes Yes Allowed Special Conditions Of Tender All Bidders (Mandatory) 3 Preferably Manufacturers Should Normal Applicable To Yes Yes Allowed Participate. Participating Traders/Agents All Bidders (Optional) Must Attach Authorization Letter Issued By The Oem Or Oem Authorized Stockiest Along With Their OffEr. Authorization Letter Should Preferably Be Tender Speciï¬C. In Case Of General Authorization Letter, It Must Clearly Indicate The Validity Period/Expiry Date. OffErs With General Authorization Letter Silent On Validity Period/Expiry Date Will Not Be Considered For Placement Of Order And That OffEr Is Liable To Be Ignored. (Please Refer Para 3.4 Of Part B Of Sr Tender Conditions). 4 Procurement Of The Item Is Restricted To Normal Applicable To Yes Yes Not Allowed Local Suppliers With Minimum Local All Bidders Content Of 20% (Class-I Or Class-Ii Local Supplier As Deï¬Ned In Railway Board Letter No.2020/Rs(G)/779/2/Pt.1 Dated 25.09.2020 With Latest Amendments, If Any) Only And The Vendors Who Do Not Qualify To Be Local Suppliers (I.E.), Non- Local Suppliers With Local Content Less Than 20%) Should Not Quote In The Tender As Their OffErs Shall Not Be Considered For Any Ordering. In Case Any Vendor Who Does Not Qualify To Be A Local Supplier For The Tendered Item Participates In The Tender, It Does So At Its Own Risk And Cost And Railways Shall Not Be Liable For Any Loss Or Damage Caused To The Vendor. OffEr Of The ϬRm Shall Be Summarily Rejected In Case Of Non-Compliance Of Above Declaration. For More Details, The Tenderer Shall Refer Para 16.0 Of Part B Of Sr Tender Conditions Attached To This Tender Document. Page 3 Of 14 Run Date/Time: 10/07/2025 11:56:48Stores/Southern Rly Tender Document Tender No 16255011 Closing Date/Time 11/08/2025 14:30 5 Earnest Money Deposit (Emd) Shall Be Normal Applicable To Yes Yes Not Allowed Deposited By All Vendors For Tenders With All Bidders Estimated Value Above Rs.25 Lakhs Subject To The Applicable Exemptions. The Para 2.1 Of The Part A Of Sr Tender Conditions With Regard To Emd Exemption Is Superseded As Below And The Conditions Mentioned Here Below Will Prevail Over That Of In Para 2.1 Of The Part A Of Sr Tender Conditions Attached To This Tender Document: Emd Amount Shall Be Mentioned In All Tenders Irrespective Of The Nature Of Tender As Per The Emd Amount Mentioned In Clause 2.3 Of Part A Of Sr Tender Conditions Or As Decided By The Purchaser Under The Policy. There Shall Be No Exemption From Submission Of Emd For Any Tender Or By Any Tenderer Subject To Provisions Under Clause 10.4.3 Of Part A Of Sr Tender Conditions Except Following : (I) Emd Shall Normally Not Be Called Against Tenders With Estimated Value Up To Rs.25 Lakhs (Including Single Tenders, Global Limited Tenders) Except Cases Where Competent Authority Incorporates The Condition To Call For Emd. Ii) Public Sector Undertakings (Psus) A. Psus Owned By Ministry Of Railways And B. Psus For The Group Of Items That Are Manufactured By Them. Iii) Mses Registered Under Udyam Registration Shall Be Eligible For Exemption From Payment Of Emd Irrespective Of Relevance Of Product Category For Which They Are Registered With Udyam. However, Traders/Distributors/Sole Agent/Works Contract Are Not Exempted From Payment Of Emd As They Are Excluded From The Purview Of The Policy. Iv) Other Railways, Indian Ordinance Factories And Govt. Departments. V) In Exceptional Cases, Where Emd Exemption Is Speciï¬Cally Incorporated In Tender Conditions. Vi) Vendors Registered With Southern Railway For The Trade Group/Trade Groups Of The Tendered Item . Vii) Regular And Development Vendors Appearing On The Approved Vendor Lists Of Rdso/Pus/ Core Etc., For Those Speciï¬C Item For Which They Are On The Approved List, Subject To Approval Status Being Valid On The Date Of Tender Closing. Viii) Vendors Registered With Railways For Supply Of Medicine, Medical Equipments And Consumables Shall Be Exempted From Submission Of Emd For These Items. Ix) In Tenders Issued Against Pac, Oem In Whose Favour Pac Has Been Issued Shall Be Exempted From Submitting Emd. Kvic And Acash Shall Be Exempted From Emd For Items Supplied By Them. In Case Of Submission Of Earnest Money Deposit In The Form Of Bank Guarantee, Please Refer Annexure- 6 Of Sr Tender Conditions For The Proforma For Bg. Page 4 Of 14 Run Date/Time: 10/07/2025 11:56:48Stores/Southern Rly Tender Document Tender No 16255011 Closing Date/Time 11/08/2025 14:30 6 All The Tenderers Shall Have To Submit Normal Applicable To Yes Yes Allowed Clause-Wise Compliance Of Speciï¬Cation All Bidders (Mandatory) Mentioned In Bid Documents And Drawings Enclosed Along With This Tender If Any Or Product Catalogue For The Make And Model OffEred Should Be Submitted By The Tenderer, Spelling Out Deviations, If Any, To Ascertain Technical Suitability. An OffEr, Whose Technical Suitability Cannot Be Ascertained, May Be Liable To Be Ignored. 7 Inter - Se Position Of Offers Would Normal Applicable To Yes Yes Not Allowed Be Determined Based On The Total All Bidders Value Of The OffEr That Will Be Calculated Based On I. The Cost Of The Basic Equipment As Per Table 1 (Annexure-A) Ii. Cost Of Installation & Commissioning Of Equipment. Iii. Cost Of Spares For 2 Years Normal Operation And Maintenance As Per Clause 3 Of Part-1 (Annexure-B) Iv. Duties And Taxes As Quoted By The Bidder, Insurance And Freight. V. Cost Of Camc For 5 Years, Discount At The Rate Of 10% Per Year After 2 Years Of Warranty. 8 Firms Have To Quote Cost Of Basic Normal Applicable To Yes Yes Not Allowed Machine, Essential Spares, Essential All Bidders Services, Amc Service Etc. It Is Mandatory To Submit OffErs Against All These Items, Otherwise OffEr Will Not Be Considered For Inter-Se Ranking. 5. Compliance Conditions Check List S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Have You Quoted Cost Of Basic Machine, Normal Applicable To No No Not Allowed Essential Spares, Essential Services, Amc All Bidders Service, Training Etc. It Is Mandatory To Submit OffErs Against All These Items, Otherwise OffEr Will Not Be Considered For Inter-Se Ranking. 2 Have You Attached Documents To Prove Normal Applicable To No No Not Allowed Your Eligibility And Past Performance As All Bidders Per Tender Requirement? 3 Have You Attached Certiï¬Cation Of Local Normal Applicable To No No Not Allowed Content From Statutory Auditor/ Cost All Bidders Accountant? 4 Have You Quoted Warranty Oblications As Normal Applicable To No No Not Allowed Per Tender Requirement? All Bidders 5 Have You Quoted Delivery Period Correctly Normal Applicable To No No Not Allowed And Precisely? All Bidders 6 Have You Uploaded All The Annexure Normal Applicable To No No Not Allowed Complete In All Respect As Mentioned In All Bidders Bid Documents? 7 Have You Submitted All Supporting Normal Applicable To No No Not Allowed Documents Required? All Bidders 8 Have You Read The Security Deposit (Sd) Normal Applicable To No No Not Allowed Condition At Para 10 Of Part A Of Sr All Bidders Tender Conditions Attached With This Tender Document And Uploaded Relevant Document For Seeking Exemption From Submission Of Sd? If Not, Are You Ready To Pay Security Deposit? Page 5 Of 14 Run Date/Time: 10/07/2025 11:56:48Stores/Southern Rly Tender Document Tender No 16255011 Closing Date/Time 11/08/2025 14:30 9 Are You Coming Under Mse Status Given Normal Applicable To No No Not Allowed As Per Guidelines Issued By Railway Board All Bidders For Purchase Preference Vide Letter No. 2010-Rs [G] -363-1 Dt. 05.07.2012 Or Latest. If Yes,Have You Attached Valid Documents (Udyam Registration Certificate) Towards Being Mse? 10 Have You Furnished The Statement Of Normal Applicable To No No Not Allowed Deviations?[Preferably Nil] All Bidders 11 Have You Quoted The Discount If Any In The Normal Applicable To No No Not Allowed Specified Column Only In Ireps? All Bidders 12 Have You Furnished Bank Account Details Normal Applicable To No No Not Allowed Such As Name Of The Bank And Address, All Bidders Account No., Micr, Ifsc Code And Type Of Account To Facilitate Eft Payment? 13 Please Check Our Website Before Normal Applicable To No No Not Allowed Submitting OffEr, Whether Any All Bidders Corrigendum To The Tender Has Been Issued Or Not. 14 Firm To Indicate Make-Model-Brand Normal Applicable To No No Not Allowed Offered, If Any. All Bidders 15 Have You Kept Your OffEr Valid For 120 Normal Applicable To No No Not Allowed Days? All Bidders Commercial-Compliance S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 In Case Of Road Delivery, The Date Of Normal Applicable To Yes Yes Not Allowed Delivery At Destination [Consignees End] All Bidders Shall Only Be Treated As Delivery Date Irrespective Of F.O.R. / F.O.T. Condition Mentioned Elsewhere In The Contract / Tender. 2 Tenderers May Note That Their OffEred Normal Applicable To Yes Yes Not Allowed Delivery Schedule Should Clearly Indicate All Bidders The Starting Time, Quarterly Rate Of Supply And ϬNishing Time. For OffErs With Vague Delivery Schedule Like -02 To 12 Months- Or Like -06 To 10 Months-, Delivery Period Shall Be Given As Per The Requirement Best Suited To This Oï¬Ƒce Within The Quoted Range. 3 The Bidder Conï¬Rms That Rates And Other Normal Applicable To Yes Yes Not Allowed ϬNancial Terms Quoted In Relevant All Bidders Columns Of ϬNancial Bid Will Only Be Ruling Terms For Acceptance, And Such Terms Quoted Anywhere Else Should Be Ignored. 4 Whenever Tender Is Ϭ‚Oated With Purchase Normal Applicable To Yes Yes Not Allowed Restriction From Sources Approved By All Bidders Nominated Authorities And There Exists A Suspected Cartel Situation By Approved Sources Or The Rates Available From Approved Source/Sources Are Adjudged Unreasonably High, Despite Fair EffOrts As Permissible, The Purchaser Reserves The Right To Place Orders On ϬRm(S) Outside The Approved Vendor List, Without Any Restrictions.(Please Refer Para 4.0 Of Part B Of Sr Tender Conditions Document Attached To This Tender Document For Further Details.) Page 6 Of 14 Run Date/Time: 10/07/2025 11:56:48Stores/Southern Rly Tender Document Tender No 16255011 Closing Date/Time 11/08/2025 14:30 5 [A] All The Bidders/Tenderers Should Ensure Normal Applicable To Yes Yes Not Allowed That They Are Gst Compliant And Their All Bidders Quoted Tax Structure/Rates Are As Per The Gst Law. Firms Must Indicate Its Gst Registration Number Along With Their Offer. [B] In Case The Successful Tenderer Is Not Liable To Be Registered Under Cgst/Igst /Utgst/Sgst Act, The Railway Shall Deduct The Applicable Gst From His/Their Bills Under Reverse Charge Mechanism (Rcm) And Deposit The Same To The Concerned Tax Authority. [C] The ϬRm Should Indicate The Tariff Code (Hsn Code) For Claiming Gst For The Tendered Item. [D] The OffEr Shall Be Evaluated Based On The Gst Rate As Quoted By Each Bidder And Same Will Be Used For Determining The Inter-Se Ranking. While Submitting OffEr, It Shall Be The Responsibility Of The Bidder To Ensure That They Quote Correct Gst Rate And Hsn Number. [E] It Shall Be The Responsibility Of The Bidders To Quote Correct Hsn Number And Corresponding Gst Rate. The Purchaser Shall Not Be Responsible For Any Misclassiï¬Cation Of Hsn Number Or Incorrect Gst Rate, If Quoted By The Bidder. [F] Wherever, The Successful Bidder Invoices The Goods At Gst Rate Or Hsn Number Which Is DiffErent From That Incorporated In The Purchase Order, Payment Shall Be Made As Per Gst Rate Which Is Lower Of The Gst Rate Incorporated In The Purchase Order Or Billed. [G] Vendor Is Informed That She/He Would Be Required To Adjust Her/His Basic Price To The Extent Required By Higher Tax Bill As Per Invoice To Match The All Inclusive Price As Mentioned In The Purchase Order. [H] Any Amendment To Gst Rate Or Hsn Number In The Contract Shall Be As Per The Contractual Conditions And Statutory Amendments In The Quoted Gst Rate And Hsn Number, Under Svc. 6 Please Refer Para 15.0 Of Part - B Of Sr Normal Applicable To Yes Yes Not Allowed Tender Conditions Attached With This All Bidders Tender Document For Details Regarding Benefits Of Mse As Per Public Procurement Policy. 7 For Public Procurement (Preference To Normal Applicable To Yes Yes Not Allowed Make In India) Policy, Please Refer Para All Bidders 16.0 Of Part- B Of Sr Tender Conditions Attached To This Tender Document. Page 7 Of 14 Run Date/Time: 10/07/2025 11:56:48Stores/Southern Rly Tender Document Tender No 16255011 Closing Date/Time 11/08/2025 14:30 8 Bidder Shall Accept The Following Normal Applicable To Yes Yes Allowed Declaration [Land Border Condition] By All Bidders (Mandatory) Quoting Yes Against Conf. Allowed Or Complied Column For Compliance Of Oï¬Ƒce Memorandum Of Department Of Expenditure, Ministry Of Finance Om No. F.No.6/18/2019-Ppd Dated 23.07.2020. If Such Certiï¬Cate Given By A Bidder Whose Bid Is Accepted Is Found To Be False, This Would Be A Ground For Immediate Termination And Further Legal Action In Accordance With Law. I/We Have Read The Clause Regarding Restrictions On Procurement From A Bidder Of A Country Which Shares A Land Border With India. I/We Certify That This Bidder Is Not From Such A Country Or , If From Such A Country, Has Been Registered With The Competent Authority. I/We Hereby Certify That This Bidder, Fulfills All Requirements In This Regard, And Is Eligible To Be Considered. (Where Applicable, Evidence Of Valid Registration By The Competent Authority Shall Be Attached.) 9 1) Bidders Are Instructed Not To Indulge In Normal Applicable To Yes Yes Not Allowed Any Anti-Competitive Practices. As Per The All Bidders Provisions Of Competition Act,2002, Railways Can Make A Reference To The Competition Commission Of India For Making An Enquiry In Case Of Suspected Anti-Competitive Behavior By The Bidders. 2) Collusive Bidding, Bid Rotation, Bid Suppression, Complementary Bidding, Market Allocation And Sub-Contracting Arrangements Fall Under The Purview Of Bid Rigging Which Would Cause Appreciable Adverse EffEct On Competition. 3) Competition Commission Of India Can Impose Heavy Penalties Such As: Penalty Upto 10% Of The Average Turnover For The Last Three Preceding ϬNancial Years Upon Each Of Such Enterprises Which Are Parties To Bid-Rigging And Can Even Order The Parties To Cease And Desist. 10 A) For : Destination. By Road. Normal Applicable To Yes Yes Not Allowed Accordingly, The ϬRms Are Advised To All Bidders Quote On For Destination Basis By Road And Offers With Deviations Are Liable To Be Ignored. B) Door Delivery Shall Be Made To The Consignees Along With Delivery Challan Postal Address Of The Consignee Of Group G1 Is: Sse/C&W/Art/Jtj Postal Address Of The Consignee Of Group G2 Is: Sse/C&W/Art/Bbq Southern Railway Gst No. 33Aaagm0289c1zq. Page 8 Of 14 Run Date/Time: 10/07/2025 11:56:48Stores/Southern Rly Tender Document Tender No 16255011 Closing Date/Time 11/08/2025 14:30 11 Failure Consequences: In Case The ϬRm Normal Applicable To Yes Yes Not Allowed Fails To Execute The Contract Within The All Bidders Original Delivery Period, The Purchaser Will Be Entitled To Impose Liquidated Damages For Extension Of Delivery Period. For Any Reason, If The Supplier Fails To Supply Goods And/Or Service As Per The Conditions Of Contract, As Amended From Time To Time, Purchaser Shall Have The Right To Levy Damages From The Supplier For Failing To Comply With The Contractual Conditions, Not By The Way Of Penalty, An Amount Equal To Security Deposit Of The Defaulted Order Amount. These Damages Shall Be Treated As Recoveries Outstanding Against The Vendor And Dealt With Accordingly. 12 Tenderers To Acknowledge Having Read Normal Applicable To Yes Yes Not Allowed And Also Accept The Irs Conditions Of All Bidders Contract, Sr Tender Conditions, Special And Other Conditions Speciï¬Ed In This Tender Document/Attached To This Tender Document. Page 9 Of 14 Run Date/Time: 10/07/2025 11:56:48Stores/Southern Rly Tender Document Tender No 16255011 Closing Date/Time 11/08/2025 14:30 13 Security Deposit Shall Be Taken From All Normal Applicable To Yes Yes Not Allowed Vendors For Contract Value Above Rs.25 All Bidders Lakhs. Security Deposit Is 5% Of Total Value Of Contract Subject To Max Rs. 50 Lakhs For Contract Value Above 25 Lakhs And Up To Rs.50 Crore. Subject To The Applicable Exemptions. Security Deposit From Successful Tenderers Should Be Received In Purchase Oï¬Ƒce Within 21 Days From The Date Of Communication Of Acceptance With Respect To The Purchaser. There Shall Be No Exemption From Submission Of Security Deposit For Any Tender Or By Any Tenderer Except Following: A) The Store Contract Cases Of Value Upto Rs.25 (Twenty Five) Lakh, B) Other Railways And Government Departments In Terms Of Railway Boards Letter No. 2004/Rs(G)/779/11 Dated 24.07.2007 C) Indian Ordinance Factories In Terms Of Railway Boards Letter No.92/Rss(G)/363/1 Dated 08.04.1993 D) Psus Owned By Ministry Of Railways And Psus For The Group Of Items That Are Manufactured By Them In Terms Of Railway Boards Letter No.2003/Rs(G)/779/5 Dated 10.09.2004 E) In Tenders Issued Against Pac, Oem In Whose Favour Pac Has Been Issued Shall Be Exempted From Submitting Sd. Kvic And Acash Shall Be Exempted From Sd For Items Supplied By Them. F) Vendors Registered With Railways For The Trade Group Of The Item Tendered Shall Be Exempted From Sd For Orders Valued Up To Their Monetary Limit Of Registration. G) Vendors Appearing On The Approved Vendor Lists Of Rdso/Pus/Core Subject To Approval Status Being Valid On The Date Of Tender Closing H) Vendors Registered With Railway For Supply Of Medicine, Medical Equipments And Consumables Shall Be Exempted From Submission Of Sd For These Items. (Please Refer Para 10.0 Of Part A Of Sr Tender Conditions Enclosed To This Tender Document For Further Details On This Clause). 14 (A) Free Delivery To Consignee. Supply Of Normal Applicable To Yes Yes Not Allowed Machine Shall Be Made As Per The All Bidders Delivery Schedule Chart Enclosed. (B) Bill Payment: After Successful Completion Of Purchase Order, ϬRm Has To Submit The Bill On-Line Through Ireps Portal Only For Payment. In This Regard, The Following Documents Have To Be Uploaded Based On The Crn (R-Note) Issued By Railway (A) Invoice, Gst Declaration( I.E. Self Declaration Regarding Aggregate Annual Turnover In A ϬNancial Year: Less (Or) More Than 50 Crores / Less(Or) More Than 100 Crores/Less (Or) More Than 500 Crores. If More Than 500 Crores, E-Invoice Is Required To Be Uploaded.), Rnote, Neft Mandatory. (B) Warranty/Guarantee Certiï¬Cate, Rites Certiï¬Cate, Test Report, Dealership Certiï¬Cate (Or) Proof Of Purchase From Authorized Dealer, Calibration Certiï¬Cate, Commissioning Report Whichever Is Applicable. Page 10 Of 14 Run Date/Time: 10/07/2025 11:56:48Stores/Southern Rly Tender Document Tender No 16255011 Closing Date/Time 11/08/2025 14:30 15 Ca Certiï¬Cate Clause:- Tenderers Shall Normal Applicable To Yes Yes Not Allowed Provide A Certiï¬Cate From The Statutory All Bidders Auditor Or Cost Auditor Of The Company Or From A Practicing Cost Accountant /Chartered Account Giving The Percentage Of Local Content. The Bidder Shall Give Self-Certiï¬Cation For Local Content In The Quoted Item (Goods/Works/Services) At The Time Of Tendering. However, At The Time Of Execution Of The Project, For All Contract Above Inr 10 Crore, The Contractor/Supplier Shall Be Required To Give Local Content Certiï¬Cation Duly Certiï¬Ed By Cost/Chartered Accountant In Practice. For Cases Where It Is Not Possible To Provide Certiï¬Cation By Cost/Chartered Accountant At The Time Of Execution Of Project, The Supplier Shall Be Permitted To Provide The Certiï¬Cate For Local Content From Cost/Chartered Accountant After Completion Of The Contract, Within Time Limit Acceptable To The Procuring Entity. In Case The Contractor/Supplier Does Not Meet The Stipulated Local Content Requirement And The Category Of The Supplier Changes From Class-I To Class- Ii/Non-Local Or From Class-Ii To Non-Local, A Penalty Upto 10% Of The Contract Value May Be Imposed. However, Contract Once Awarded Shall Not Be Terminated On This Account. The Tenderer Shall Refer Para.16.1 Of Part.B Of Sr Tender Conditions Attached To This Tender Document. 16 The Tenderers Shall Submit A Copy Of Normal Applicable To Yes Yes Not Allowed Certiï¬Cate Stating That All Their Statements All Bidders / Documents Submitted Along With Bid Are True And Factual. Standard Format Of Certiï¬Cate To Be Submitted By The Bidder Is Enclosed As Annexure-I. Non-Submission Of Above Certiï¬Cate By The Bidder Shall Result In Summary Rejection Of His/Their Bid. It Shall Be Mandatorily Incumbent Upon The Tenderer To Identify, State And Submit The Supporting Documents Duly Self-Attested / Digitally Signed By Which They/ He Is Qualifying The Qualifying Criteria Mentioned In The Tender Document. It Will Not Be Obligatory On The Part Of Tender Committee / Accepting Authority To Scrutinize Beyond The Submitted Document Of Tenderer As Far As His Qualification For The Tender Is Concerned. 17 Please Enter The Percentage Of Local Normal Applicable To No Yes Allowed Content In The Material Being OffEred. All Bidders (Optional) Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. The Deï¬Nition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. General Instructions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading Page 11 Of 14 Run Date/Time: 10/07/2025 11:56:48Stores/Southern Rly Tender Document Tender No 16255011 Closing Date/Time 11/08/2025 14:30 1 Railway Is Not Bound To Accept The Lowest Normal Applicable To No No Not Allowed Or Any Tender Or To Assign Any Reason For All Bidders Doing So And Railway Reserves The Right To Accept/Cancel Any Tender In Respect Of The Whole Or Any Portion Of The Items Specified In The Schedule Annexed (Or Tender Schedule) And The Contractor Shall Be Required To Supply The Same At The Rate Quoted. 2 1. For Any Queries Against This Tender, Normal Applicable To No No Not Allowed Please Contact Cmm/M/Sr At 9003060762. All Bidders 2. Any Technical Clariï¬Cation Regarding Drawing/Speciï¬Cation Can Be Obtained From The Oï¬Ƒce Of The Pcme/Sr/Mas. Dy.Cme/Planning/Mas Mobile No. 9003060403 And Mail Id [email protected]. Drawing (S) / Speciï¬Cation (S) Can Also Be Obtained From The Above Oï¬Ƒce After Payment Requisite Cost. 3 Vendors May Please Note That Giving Normal Applicable To No No Not Allowed Intimation Regarding The Tender In Open All Bidders Tender Cases Or Giving Limited Tender Enquiry Does Not Guarantee The Suitability Of OffEr For Placement Of Purchase Order. Railway Reserve The Right To Place Purchase Order Subject To Fulï¬Lment Of Technical/Commercial Eligibility Conditions/Tender Conditions. 4 All Other Terms & Conditions As Per Irs Normal Applicable To No No Not Allowed Condition And Gcc. All Bidders Other Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 A) Inspection By Tpi (Third Party Normal Applicable To No No Not Allowed Inspection Agency). Firm To Indicate All Bidders Complete Works Address Where Inspection Will Be Conducted. The Tenderer Shall Refer Annexure 13 Of Sr Tender Conditions For Further Details Regarding Tpi Clause. Please Note That OffErs With Inspection/Visual Inspection By Tpi Against Test Certiï¬Cate/Guarantee Certiï¬Cate /Work Test Certiï¬Cate Is Liable To Be Ignored. For Further Details Regarding Tpi Clause, The Tenderer Shall Refer Annexure 13 Of Sr Tender Conditions Attached To This Tender Document. Alternatively, Tenderers May Please Refer The Attachment Tpi Conditions Enclosed To This Tender Document For Ready Reference Of Bidders Regarding Tpi Clause. B) Bidder Shall Indicate Place Of Inspection For Pre-Dispatch Inspection Duly Enclosing The Documentary Evidence. Note:- Any Request For Change In Place Of Inspection Shall Only Be Entertained With Documentary Evidence. 2 Marking : Manufacturer To Mark His Normal Applicable To Yes Yes Not Allowed Name And Date Of Manufacture As Per All Bidders Drawing, Wherever Indicated, Or At A Location Where It May Not Get Obliterated In Service On The Item Being Supplied By Them Against The Purchase Order. Supplies Received Without This Are Liable To Be Rejected By Consignee. Page 12 Of 14 Run Date/Time: 10/07/2025 11:56:48Stores/Southern Rly Tender Document Tender No 16255011 Closing Date/Time 11/08/2025 14:30 3 I/We Agree To Supply The Tendered Stores Normal Applicable To Yes Yes Not Allowed At The Rates Quoted By Me/Us In All Bidders Accordance With The Irs Conditions Of Contract, Sr Tender Conditions, Special And Other Conditions Speciï¬Ed In This Tender Document/ Attached With This Tender Document. 4 Machines Should Have Warranty Of 24 Normal Applicable To Yes Yes Not Allowed Months From Date Of Successful All Bidders Commissioning, Not From The Date Of Delivery As Mentioned Above In The Schedule Of Requirements. 5 No Developmental Order Will Be Placed For Normal Applicable To Yes Yes Not Allowed The Tendered Item. All Bidders 6 Post Warranty Camc Will Be Concluded By Normal Applicable To Yes Yes Not Allowed End-User Consignee At Their End After All Bidders Warranty Period, If Required. 7 Security Deposit Is To Be In Favour Of Normal Applicable To Yes Yes Not Allowed Sr.Dfm/Mas.Format Can Be Had From All Bidders Annexure 5 In The Document Tender Conditions For Electronic Tenders Uploaded. 8 Evaluation Will Be Group -Wise Normal Applicable To Yes Yes Not Allowed All Bidders Special Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Insurance Charges Should Be Quoted In Normal Applicable To No No Not Allowed Other Charges Column Against The All Bidders Particular Items. No Separate Line Has Been Provided For Insurance Charges. Technical-Compliances S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Bidders Must Submit Their Technical Bids Normal Applicable To Yes Yes Allowed As Per Format Annexure C And Other All Bidders (Mandatory) Annexures As Required In Bid Documents. Tenderers Are Required To Submit Complete Details Including Values, Write- Up, Drawings, Sketch, Brochure Etc. As Per Requirement Speciï¬Ed In Respective Clauses Mentioned Therein. In Case Of Incomplete / Sketchy Information, The Technical OffEr Being Incomplete Is Liable To Be Rejected. Tenderers Should Clearly Indicate Compliance. 6. Bidders Shall Confirm And Certify On The Behalf Of The Tenderer Including Its Constituents As Under: S.No. Description 1 I/We The Tenderer (S) Am/Are Signing This Document After Carefully Reading The Contents. 2 I/We The Tenderer(S) Also Accept All The Conditions Of The Tender And Have Signed All The Pages In Confirmation Thereof. I/We Hereby Declare That I/We Have Downloaded The Tender Documents From Indian Railway Website Www.Ireps.Gov.In . I/We Have Verified The Content Of The Document From The Website And There Is No Addition, No Deletion Or No Alteration To The 3 Content Of The Tender Document. In Case Of Any Discrepancy Noticed At Any Stage I.E. Evaluation Of Tenders, Execution Of Contract Or Payment, The Master Copy Available With The Railway Administration Shall Be Final And Binding Upon Me/Us. I/We Declare And Certify That I/We Have Not Made Any Misleading Or False Representation In The Forms, Statements And 4 Attachments In Proof Of The Qualification Requirements. I/We Also Understand That My/Our Offer Will Be Evaluated Based On The Documents/Credentials Submitted Along With The Offer 5 And Same Shall Be Binding Upon Me/Us. I/We Declare That The Information And Documents Submitted Along With The Tender By Me/Us Are Correct And I/We Are Fully 6 Responsible For The Correctness Of The Information And Documents, Submitted By Us. I/We Certify That I/We The Tenderer(S) Is/Are Not Blacklisted Or Debarred By Railways Or Any Other Ministry / Department Of 7 Govt. Of India From Participation In Tender On The Date Of Submission Of Bids, Either In Individual Capacity Or As A Huf/ Member Of The Partnership Firm/Llp/Jv/Society/Trust. Page 13 Of 14 Run Date/Time: 10/07/2025 11:56:48Stores/Southern Rly Tender Document Tender No 16255011 Closing Date/Time 11/08/2025 14:30 I/We Understand That If The Contents Of The Certificate Submitted By Us Are Found To Be Forged/False At Any Time During Process For Evaluation Of Tenders, It Shall Lead To Forfeiture Of The Emd And May Also Lead To Any Other Action Provided In The 8 Contract Including Banning Of Business For A Period Of Upto Two Year. Further, I/We And All My/Our Constituents Understand That My/Our Offer Shall Be Summarily Rejected. I/We Also Understand That If The Contents Of The Certificate Submitted By Us Are Found To Be False/Forged At Any Time After The 9 Award Of The Contract, It Will Lead To Termination Of The Contract, Along With Forfeiture Of Security Deposit And May Also Lead To Any Other Action Provided In The Contract Including Banning Of Business For A Period Of Upto Two Year. I/We Have Read The Clause Regarding Restriction On Procurement From A Bidder Of A Country Which Shares A Land Border With India And Certify That I Am/We Are Not From Such A Country Or, If From Such A Country, Have Been Registered With The 10 Competent Authority. I/We Hereby Certify That I/We Fulfil All The Requirements In This Regard And Am/Are Eligible To Be Considered (Evidence Of Valid Registration By The Competent Authority Is Enclosed) 7. Documents Attached With Tender S.No. Document Name Document Description 1 5446564.Pdf Irs Conditions 2 5446567.Pdf Sr Tender Conditions 3 5446589.Pdf Tpi Guidelines 4 5463672.Pdf Delivery Schedule Chart 5 5446667.Pdf Technical Specification 6 5453473.Pdf Annexure-I 7 5446617.Pdf Special Conditions Of Tender 7. Responsiveness S.No. Description 1 Validity Of Offer:-120 Days, No Deviation From The Offer Validity Period Stipulated In The Tender Is Permitted. I/We Have Carefully Gone Through The Irs Conditions Of Contract (Included And Uploaded Along With The Bid Document) Particularly Para 2500 Pertaining To Code Of Integrity, Misdemeanor And Penalties. I/We Hereby Certify That No Other Concerns Or Aï¬Ƒliates (Such As Having Common Partner/Director/Promoter/Owner/Holding Company Decision Control Etc.) Have Participated In This Tender Which Can Give Rise To A ConflIct Of Interest Or Fall Under Anti-Competitive Practices. We Understand That The 2 OffErs Of All Such Sister Concerns Including Ours Are Liable To Be Rejected As Per Relevant Provisions Of Irs Terms And Conditions. I/We, Aï¬Ƒrm That We Shall Abide By The Code Of Integrity In General, With Speciï¬C Reference To ConflIct Of Interest [Para 2502 (E)], Anti Competitive Practices [Para 2502(C)] And Obligation To Proactive Disclosures [Para 2503]. I/We Understand That We Are Fully Responsible For The Above Declaration And It Shall Not Be The Railways Responsibility To Verify The Same. I/We Are Aware That We Shall Be Liable For All Consequences Of Violation Of Code Of Integrity, If Detected, At Any Stage. The Tenderers In Their Bid Shall Indicate The Details Of Their Gst Jurisdictional Assessing Officers (Designation, Address & Email Id). In Case Of A Contract Award, A Copy Of Purchase Order Shall Be Immediately Forwarded By Purchaser To The Gst Jurisdictional Assessing Officer Mentioned In Tenderers Bid This Tender Complies With Public Procurement Policy (Make In India) Order 2017, Dated 15/06/2017, Issued By Department Of Industrial Promotion And Policy, Ministry Of Commerce, Circulated Vide Railway Board Letter No. 2015/Rs(G)/779/5 Dated 03/08/2017 And 27/12/2017 And Amendments/ Revisions Thereof. As A Tender Inviting Authority, The Undersigned Has Ensured That The Issue Of This Tender Does Not Violate Provisions Of Gfr Regarding Procurement Through Gem. Digitally Signed By Dy.Cmm/Traction ( Irene Neethu Singh Densingh ) , Spares For 2 Years Normal Operation And Maintenance With Price Breakup Of Individual Items As Per Clause 3 Of Part-1 (Annexure-B) [ Warranty Period: 30 Months After The Date Of Delivery ] ] , Cost Of Installation & Commissioning Of Equipment ] At (Location) Cws/Jtj, Sr Tamil Nadu 1.00 Numbers Group G2-Sse/C&W/Art/Bbq Page 1 Of 14 Run Date/Time: 10/07/2025 11:56:48Stores/Southern Rly , Supply Of Hydraulic Re-Railing Equipment With Concomitant Accessories And Additional Acces Sories (Pump Set With Petrol Engine-1 No, Portable Control Table-1 No, High Pressure Hoses-1 Set And Roller Carriage-1 No) As Per Technical Specification Attached. [ Warranty Period: 24 Months After The Date Of Del Ivery ] ] , Post Warranty Comprehensive Annual Maintenance Charges ( After 2 Years Free Warranty Period ) Firm To Quote Separately Ie Year 1 Tab ( For 3 Rd Year). Year 2 Tab ( For 4 Th Year) , Year 3 Tab ( For 5 Th Year) ,Year 4 Tab ( For 6 Th Year) And Year 5 Tab ( For 7 Th Year) [ Warranty Period: 2 Years, Amc Period: 5 Years, Rate Of Discounting: 10 % ] ] At (Location) Sse/Bbq, Sr Tamil Nadu 1.00 Numbers 3 6507Ns01 Essential Non Stock --- Yes Tpi Agency Inr (G2) Spares (Y) Spares For 2Years Normal Operation And Maintenance With Price Breakup Of Individual Items A S Per Clause 3 Of Part-1 (Annexure-B) [ Warranty Period: 30 Months After The Date Of Delivery ] ] Consignee Sse/Bbq, Sr Tamil Nadu 1.00 Set Inspection Details Stage Inspection Not Required 4 6507Ser1 Essential Non Stock --- Yes Consignee Inr (G2) Services (Y) Cost Of Installation & Commissioning Of Equipment ] At (Location) Sse/Bbq, Sr Tamil Nadu 1.00 Numbers 3. T And C F.O.R Description Destination Delivery Period Description Delivery /Completion Rate Of Supply For All Items Commencement : Within 2 Months Of Issue Of Contract, However, Delivery Completion : Within 3 Months Thereafter Period Shall Not Exceed No. Of Days As Mentioned In Delivery Schedule Chart Attached. However, The Delivery Period Indicated Being Tentative, May Vary At The The Time Of Placement Of Order. Payment Terms S.No Description Payment Terms 1 1) 60% Payment: Upon Receipt Of The M&P, Duly Pre-Inspected By A Third -Party Inspection (Tpi) Agency, Receipted At The Site By The Consignee In Good Condition And Submission Of A Joint Receipt Note. 2) 20% Intermediate Payment: After Successful Installation And Commissioning And Submission Of A Joint Commissioning Note. 3) Final 20% Payment: After Commissioning Of The M&P At The Consignees End For A Minimum Period Of 30 Days, Upon Submission Of A 10% Warranty Bank Guarantee And A Proving Test Certificate Statutory Variation Clause Page 2 Of 14 Run Date/Time: 10/07/2025 11:56:48Stores/Southern Rly Tender Document Tender No 16255011 Closing Date/Time 11/08/2025 14:30 S.No Description 1 Statutory Variation In Taxes And Duties, Or Fresh Imposition Of Taxes And Duties By State/ Central Governments In Respect Of The Items Stipulated In The Contract (And Not The Raw Materials Thereof), Within The Original Delivery Period Stipulated In The Contract, Or Last Unconditionally Extended Delivery Period Shall Be To Railways Account. Only Such Variation Shall Be Admissible Which Takes Place After The Submission Of Bid. No Claim On Account Of Statutory Variation In Respect Of Existing Tax/Duty Will Be Accepted Unless The Tenderer Has Clearly Indicated In His OffEr The Rate Of Tax/Duty Considered In His Quoted Rate. No Claim On Account Of Statutory Variation Shall Be Admissible On Account Of Misclassiï¬Cation By The Supplier/ Contractor. Standard Governing Conditions S.No Description 1 The Bidder Agrees To Supply The Tendered Stores At The Rates Quoted By Him In Accordance With The Latest Version Of Irs Conditions Of Contract (Attached As Irs Conditions Of Contract To This Tender Document For Ready Reference) And Southern Railway Tender Conditions (Attached As Sr Tender Conditions To This Tender Document For Ready Reference). 4. Eligibility Conditions Special Eligibility Criteria S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Supply To Be Strictly As Per Speciï¬Cations Normal Applicable To Yes Yes Not Allowed Document Uploaded With This Tender. All Bidders 2 Please Refer Attached Document Titled Normal Applicable To Yes Yes Allowed Special Conditions Of Tender All Bidders (Mandatory) 3 Preferably Manufacturers Should Normal Applicable To Yes Yes Allowed Participate. Participating Traders/Agents All Bidders (Optional) Must Attach Authorization Letter Issued By The Oem Or Oem Authorized Stockiest Along With Their OffEr. Authorization Letter Should Preferably Be Tender Speciï¬C. In Case Of General Authorization Letter, It Must Clearly Indicate The Validity Period/Expiry Date. OffErs With General Authorization Letter Silent On Validity Period/Expiry Date Will Not Be Considered For Placement Of Order And That OffEr Is Liable To Be Ignored. (Please Refer Para 3.4 Of Part B Of Sr Tender Conditions). 4 Procurement Of The Item Is Restricted To Normal Applicable To Yes Yes Not Allowed Local Suppliers With Minimum Local All Bidders Content Of 20% (Class-I Or Class-Ii Local Supplier As Deï¬Ned In Railway Board Letter No.2020/Rs(G)/779/2/Pt.1 Dated 25.09.2020 With Latest Amendments, If Any) Only And The Vendors Who Do Not Qualify To Be Local Suppliers (I.E.), Non- Local Suppliers With Local Content Less Than 20%) Should Not Quote In The Tender As Their OffErs Shall Not Be Considered For Any Ordering. In Case Any Vendor Who Does Not Qualify To Be A Local Supplier For The Tendered Item Participates In The Tender, It Does So At Its Own Risk And Cost And Railways Shall Not Be Liable For Any Loss Or Damage Caused To The Vendor. OffEr Of The ϬRm Shall Be Summarily Rejected In Case Of Non-Compliance Of Above Declaration. For More Details, The Tenderer Shall Refer Para 16.0 Of Part B Of Sr Tender Conditions Attached To This Tender Document. Page 3 Of 14 Run Date/Time: 10/07/2025 11:56:48Stores/Southern Rly Tender Document Tender No 16255011 Closing Date/Time 11/08/2025 14:30 5 Earnest Money Deposit (Emd) Shall Be Normal Applicable To Yes Yes Not Allowed Deposited By All Vendors For Tenders With All Bidders Estimated Value Above Rs.25 Lakhs Subject To The Applicable Exemptions. The Para 2.1 Of The Part A Of Sr Tender Conditions With Regard To Emd Exemption Is Superseded As Below And The Conditions Mentioned Here Below Will Prevail Over That Of In Para 2.1 Of The Part A Of Sr Tender Conditions Attached To This Tender Document: Emd Amount Shall Be Mentioned In All Tenders Irrespective Of The Nature Of Tender As Per The Emd Amount Mentioned In Clause 2.3 Of Part A Of Sr Tender Conditions Or As Decided By The Purchaser Under The Policy. There Shall Be No Exemption From Submission Of Emd For Any Tender Or By Any Tenderer Subject To Provisions Under Clause 10.4.3 Of Part A Of Sr Tender Conditions Except Following : (I) Emd Shall Normally Not Be Called Against Tenders With Estimated Value Up To Rs.25 Lakhs (Including Single Tenders, Global Limited Tenders) Except Cases Where Competent Authority Incorporates The Condition To Call For Emd. Ii) Public Sector Undertakings (Psus) A. Psus Owned By Ministry Of Railways And B. Psus For The Group Of Items That Are Manufactured By Them. Iii) Mses Registered Under Udyam Registration Shall Be Eligible For Exemption From Payment Of Emd Irrespective Of Relevance Of Product Category For Which They Are Registered With Udyam. However, Traders/Distributors/Sole Agent/Works Contract Are Not Exempted From Payment Of Emd As They Are Excluded From The Purview Of The Policy. Iv) Other Railways, Indian Ordinance Factories And Govt. Departments. V) In Exceptional Cases, Where Emd Exemption Is Speciï¬Cally Incorporated In Tender Conditions. Vi) Vendors Registered With Southern Railway For The Trade Group/Trade Groups Of The Tendered Item . Vii) Regular And Development Vendors Appearing On The Approved Vendor Lists Of Rdso/Pus/ Core Etc., For Those Speciï¬C Item For Which They Are On The Approved List, Subject To Approval Status Being Valid On The Date Of Tender Closing. Viii) Vendors Registered With Railways For Supply Of Medicine, Medical Equipments And Consumables Shall Be Exempted From Submission Of Emd For These Items. Ix) In Tenders Issued Against Pac, Oem In Whose Favour Pac Has Been Issued Shall Be Exempted From Submitting Emd. Kvic And Acash Shall Be Exempted From Emd For Items Supplied By Them. In Case Of Submission Of Earnest Money Deposit In The Form Of Bank Guarantee, Please Refer Annexure- 6 Of Sr Tender Conditions For The Proforma For Bg. Page 4 Of 14 Run Date/Time: 10/07/2025 11:56:48Stores/Southern Rly Tender Document Tender No 16255011 Closing Date/Time 11/08/2025 14:30 6 All The Tenderers Shall Have To Submit Normal Applicable To Yes Yes Allowed Clause-Wise Compliance Of Speciï¬Cation All Bidders (Mandatory) Mentioned In Bid Documents And Drawings Enclosed Along With This Tender If Any Or Product Catalogue For The Make And Model OffEred Should Be Submitted By The Tenderer, Spelling Out Deviations, If Any, To Ascertain Technical Suitability. An OffEr, Whose Technical Suitability Cannot Be Ascertained, May Be Liable To Be Ignored. 7 Inter - Se Position Of Offers Would Normal Applicable To Yes Yes Not Allowed Be Determined Based On The Total All Bidders Value Of The OffEr That Will Be Calculated Based On I. The Cost Of The Basic Equipment As Per Table 1 (Annexure-A) Ii. Cost Of Installation & Commissioning Of Equipment. Iii. Cost Of Spares For 2 Years Normal Operation And Maintenance As Per Clause 3 Of Part-1 (Annexure-B) Iv. Duties And Taxes As Quoted By The Bidder, Insurance And Freight. V. Cost Of Camc For 5 Years, Discount At The Rate Of 10% Per Year After 2 Years Of Warranty. 8 Firms Have To Quote Cost Of Basic Normal Applicable To Yes Yes Not Allowed Machine, Essential Spares, Essential All Bidders Services, Amc Service Etc. It Is Mandatory To Submit OffErs Against All These Items, Otherwise OffEr Will Not Be Considered For Inter-Se Ranking. 5. Compliance Conditions Check List S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Have You Quoted Cost Of Basic Machine, Normal Applicable To No No Not Allowed Essential Spares, Essential Services, Amc All Bidders Service, Training Etc. It Is Mandatory To Submit OffErs Against All These Items, Otherwise OffEr Will Not Be Considered For Inter-Se Ranking. 2 Have You Attached Documents To Prove Normal Applicable To No No Not Allowed Your Eligibility And Past Performance As All Bidders Per Tender Requirement? 3 Have You Attached Certiï¬Cation Of Local Normal Applicable To No No Not Allowed Content From Statutory Auditor/ Cost All Bidders Accountant? 4 Have You Quoted Warranty Oblications As Normal Applicable To No No Not Allowed Per Tender Requirement? All Bidders 5 Have You Quoted Delivery Period Correctly Normal Applicable To No No Not Allowed And Precisely? All Bidders 6 Have You Uploaded All The Annexure Normal Applicable To No No Not Allowed Complete In All Respect As Mentioned In All Bidders Bid Documents? 7 Have You Submitted All Supporting Normal Applicable To No No Not Allowed Documents Required? All Bidders 8 Have You Read The Security Deposit (Sd) Normal Applicable To No No Not Allowed Condition At Para 10 Of Part A Of Sr All Bidders Tender Conditions Attached With This Tender Document And Uploaded Relevant Document For Seeking Exemption From Submission Of Sd? If Not, Are You Ready To Pay Security Deposit? Page 5 Of 14 Run Date/Time: 10/07/2025 11:56:48Stores/Southern Rly Tender Document Tender No 16255011 Closing Date/Time 11/08/2025 14:30 9 Are You Coming Under Mse Status Given Normal Applicable To No No Not Allowed As Per Guidelines Issued By Railway Board All Bidders For Purchase Preference Vide Letter No. 2010-Rs [G] -363-1 Dt. 05.07.2012 Or Latest. If Yes,Have You Attached Valid Documents (Udyam Registration Certificate) Towards Being Mse? 10 Have You Furnished The Statement Of Normal Applicable To No No Not Allowed Deviations?[Preferably Nil] All Bidders 11 Have You Quoted The Discount If Any In The Normal Applicable To No No Not Allowed Specified Column Only In Ireps? All Bidders 12 Have You Furnished Bank Account Details Normal Applicable To No No Not Allowed Such As Name Of The Bank And Address, All Bidders Account No., Micr, Ifsc Code And Type Of Account To Facilitate Eft Payment? 13 Please Check Our Website Before Normal Applicable To No No Not Allowed Submitting OffEr, Whether Any All Bidders Corrigendum To The Tender Has Been Issued Or Not. 14 Firm To Indicate Make-Model-Brand Normal Applicable To No No Not Allowed Offered, If Any. All Bidders 15 Have You Kept Your OffEr Valid For 120 Normal Applicable To No No Not Allowed Days? All Bidders Commercial-Compliance S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 In Case Of Road Delivery, The Date Of Normal Applicable To Yes Yes Not Allowed Delivery At Destination [Consignees End] All Bidders Shall Only Be Treated As Delivery Date Irrespective Of F.O.R. / F.O.T. Condition Mentioned Elsewhere In The Contract / Tender. 2 Tenderers May Note That Their OffEred Normal Applicable To Yes Yes Not Allowed Delivery Schedule Should Clearly Indicate All Bidders The Starting Time, Quarterly Rate Of Supply And ϬNishing Time. For OffErs With Vague Delivery Schedule Like -02 To 12 Months- Or Like -06 To 10 Months-, Delivery Period Shall Be Given As Per The Requirement Best Suited To This Oï¬Ƒce Within The Quoted Range. 3 The Bidder Conï¬Rms That Rates And Other Normal Applicable To Yes Yes Not Allowed ϬNancial Terms Quoted In Relevant All Bidders Columns Of ϬNancial Bid Will Only Be Ruling Terms For Acceptance, And Such Terms Quoted Anywhere Else Should Be Ignored. 4 Whenever Tender Is Ϭ‚Oated With Purchase Normal Applicable To Yes Yes Not Allowed Restriction From Sources Approved By All Bidders Nominated Authorities And There Exists A Suspected Cartel Situation By Approved Sources Or The Rates Available From Approved Source/Sources Are Adjudged Unreasonably High, Despite Fair EffOrts As Permissible, The Purchaser Reserves The Right To Place Orders On ϬRm(S) Outside The Approved Vendor List, Without Any Restrictions.(Please Refer Para 4.0 Of Part B Of Sr Tender Conditions Document Attached To This Tender Document For Further Details.) Page 6 Of 14 Run Date/Time: 10/07/2025 11:56:48Stores/Southern Rly Tender Document Tender No 16255011 Closing Date/Time 11/08/2025 14:30 5 [A] All The Bidders/Tenderers Should Ensure Normal Applicable To Yes Yes Not Allowed That They Are Gst Compliant And Their All Bidders Quoted Tax Structure/Rates Are As Per The Gst Law. Firms Must Indicate Its Gst Registration Number Along With Their Offer. [B] In Case The Successful Tenderer Is Not Liable To Be Registered Under Cgst/Igst /Utgst/Sgst Act, The Railway Shall Deduct The Applicable Gst From His/Their Bills Under Reverse Charge Mechanism (Rcm) And Deposit The Same To The Concerned Tax Authority. [C] The ϬRm Should Indicate The Tariff Code (Hsn Code) For Claiming Gst For The Tendered Item. [D] The OffEr Shall Be Evaluated Based On The Gst Rate As Quoted By Each Bidder And Same Will Be Used For Determining The Inter-Se Ranking. While Submitting OffEr, It Shall Be The Responsibility Of The Bidder To Ensure That They Quote Correct Gst Rate And Hsn Number. [E] It Shall Be The Responsibility Of The Bidders To Quote Correct Hsn Number And Corresponding Gst Rate. The Purchaser Shall Not Be Responsible For Any Misclassiï¬Cation Of Hsn Number Or Incorrect Gst Rate, If Quoted By The Bidder. [F] Wherever, The Successful Bidder Invoices The Goods At Gst Rate Or Hsn Number Which Is DiffErent From That Incorporated In The Purchase Order, Payment Shall Be Made As Per Gst Rate Which Is Lower Of The Gst Rate Incorporated In The Purchase Order Or Billed. [G] Vendor Is Informed That She/He Would Be Required To Adjust Her/His Basic Price To The Extent Required By Higher Tax Bill As Per Invoice To Match The All Inclusive Price As Mentioned In The Purchase Order. [H] Any Amendment To Gst Rate Or Hsn Number In The Contract Shall Be As Per The Contractual Conditions And Statutory Amendments In The Quoted Gst Rate And Hsn Number, Under Svc. 6 Please Refer Para 15.0 Of Part - B Of Sr Normal Applicable To Yes Yes Not Allowed Tender Conditions Attached With This All Bidders Tender Document For Details Regarding Benefits Of Mse As Per Public Procurement Policy. 7 For Public Procurement (Preference To Normal Applicable To Yes Yes Not Allowed Make In India) Policy, Please Refer Para All Bidders 16.0 Of Part- B Of Sr Tender Conditions Attached To This Tender Document. Page 7 Of 14 Run Date/Time: 10/07/2025 11:56:48Stores/Southern Rly Tender Document Tender No 16255011 Closing Date/Time 11/08/2025 14:30 8 Bidder Shall Accept The Following Normal Applicable To Yes Yes Allowed Declaration [Land Border Condition] By All Bidders (Mandatory) Quoting Yes Against Conf. Allowed Or Complied Column For Compliance Of Oï¬Ƒce Memorandum Of Department Of Expenditure, Ministry Of Finance Om No. F.No.6/18/2019-Ppd Dated 23.07.2020. If Such Certiï¬Cate Given By A Bidder Whose Bid Is Accepted Is Found To Be False, This Would Be A Ground For Immediate Termination And Further Legal Action In Accordance With Law. I/We Have Read The Clause Regarding Restrictions On Procurement From A Bidder Of A Country Which Shares A Land Border With India. I/We Certify That This Bidder Is Not From Such A Country Or , If From Such A Country, Has Been Registered With The Competent Authority. I/We Hereby Certify That This Bidder, Fulfills All Requirements In This Regard, And Is Eligible To Be Considered. (Where Applicable, Evidence Of Valid Registration By The Competent Authority Shall Be Attached.) 9 1) Bidders Are Instructed Not To Indulge In Normal Applicable To Yes Yes Not Allowed Any Anti-Competitive Practices. As Per The All Bidders Provisions Of Competition Act,2002, Railways Can Make A Reference To The Competition Commission Of India For Making An Enquiry In Case Of Suspected Anti-Competitive Behavior By The Bidders. 2) Collusive Bidding, Bid Rotation, Bid Suppression, Complementary Bidding, Market Allocation And Sub-Contracting Arrangements Fall Under The Purview Of Bid Rigging Which Would Cause Appreciable Adverse EffEct On Competition. 3) Competition Commission Of India Can Impose Heavy Penalties Such As: Penalty Upto 10% Of The Average Turnover For The Last Three Preceding ϬNancial Years Upon Each Of Such Enterprises Which Are Parties To Bid-Rigging And Can Even Order The Parties To Cease And Desist. 10 A) For : Destination. By Road. Normal Applicable To Yes Yes Not Allowed Accordingly, The ϬRms Are Advised To All Bidders Quote On For Destination Basis By Road And Offers With Deviations Are Liable To Be Ignored. B) Door Delivery Shall Be Made To The Consignees Along With Delivery Challan Postal Address Of The Consignee Of Group G1 Is: Sse/C&W/Art/Jtj Postal Address Of The Consignee Of Group G2 Is: Sse/C&W/Art/Bbq Southern Railway Gst No. 33Aaagm0289c1zq. Page 8 Of 14 Run Date/Time: 10/07/2025 11:56:48Stores/Southern Rly Tender Document Tender No 16255011 Closing Date/Time 11/08/2025 14:30 11 Failure Consequences: In Case The ϬRm Normal Applicable To Yes Yes Not Allowed Fails To Execute The Contract Within The All Bidders Original Delivery Period, The Purchaser Will Be Entitled To Impose Liquidated Damages For Extension Of Delivery Period. For Any Reason, If The Supplier Fails To Supply Goods And/Or Service As Per The Conditions Of Contract, As Amended From Time To Time, Purchaser Shall Have The Right To Levy Damages From The Supplier For Failing To Comply With The Contractual Conditions, Not By The Way Of Penalty, An Amount Equal To Security Deposit Of The Defaulted Order Amount. These Damages Shall Be Treated As Recoveries Outstanding Against The Vendor And Dealt With Accordingly. 12 Tenderers To Acknowledge Having Read Normal Applicable To Yes Yes Not Allowed And Also Accept The Irs Conditions Of All Bidders Contract, Sr Tender Conditions, Special And Other Conditions Speciï¬Ed In This Tender Document/Attached To This Tender Document. Page 9 Of 14 Run Date/Time: 10/07/2025 11:56:48Stores/Southern Rly Tender Document Tender No 16255011 Closing Date/Time 11/08/2025 14:30 13 Security Deposit Shall Be Taken From All Normal Applicable To Yes Yes Not Allowed Vendors For Contract Value Above Rs.25 All Bidders Lakhs. Security Deposit Is 5% Of Total Value Of Contract Subject To Max Rs. 50 Lakhs For Contract Value Above 25 Lakhs And Up To Rs.50 Crore. Subject To The Applicable Exemptions. Security Deposit From Successful Tenderers Should Be Received In Purchase Oï¬Ƒce Within 21 Days From The Date Of Communication Of Acceptance With Respect To The Purchaser. There Shall Be No Exemption From Submission Of Security Deposit For Any Tender Or By Any Tenderer Except Following: A) The Store Contract Cases Of Value Upto Rs.25 (Twenty Five) Lakh, B) Other Railways And Government Departments In Terms Of Railway Boards Letter No. 2004/Rs(G)/779/11 Dated 24.07.2007 C) Indian Ordinance Factories In Terms Of Railway Boards Letter No.92/Rss(G)/363/1 Dated 08.04.1993 D) Psus Owned By Ministry Of Railways And Psus For The Group Of Items That Are Manufactured By Them In Terms Of Railway Boards Letter No.2003/Rs(G)/779/5 Dated 10.09.2004 E) In Tenders Issued Against Pac, Oem In Whose Favour Pac Has Been Issued Shall Be Exempted From Submitting Sd. Kvic And Acash Shall Be Exempted From Sd For Items Supplied By Them. F) Vendors Registered With Railways For The Trade Group Of The Item Tendered Shall Be Exempted From Sd For Orders Valued Up To Their Monetary Limit Of Registration. G) Vendors Appearing On The Approved Vendor Lists Of Rdso/Pus/Core Subject To Approval Status Being Valid On The Date Of Tender Closing H) Vendors Registered With Railway For Supply Of Medicine, Medical Equipments And Consumables Shall Be Exempted From Submission Of Sd For These Items. (Please Refer Para 10.0 Of Part A Of Sr Tender Conditions Enclosed To This Tender Document For Further Details On This Clause). 14 (A) Free Delivery To Consignee. Supply Of Normal Applicable To Yes Yes Not Allowed Machine Shall Be Made As Per The All Bidders Delivery Schedule Chart Enclosed. (B) Bill Payment: After Successful Completion Of Purchase Order, ϬRm Has To Submit The Bill On-Line Through Ireps Portal Only For Payment. In This Regard, The Following Documents Have To Be Uploaded Based On The Crn (R-Note) Issued By Railway (A) Invoice, Gst Declaration( I.E. Self Declaration Regarding Aggregate Annual Turnover In A ϬNancial Year: Less (Or) More Than 50 Crores / Less(Or) More Than 100 Crores/Less (Or) More Than 500 Crores. If More Than 500 Crores, E-Invoice Is Required To Be Uploaded.), Rnote, Neft Mandatory. (B) Warranty/Guarantee Certiï¬Cate, Rites Certiï¬Cate, Test Report, Dealership Certiï¬Cate (Or) Proof Of Purchase From Authorized Dealer, Calibration Certiï¬Cate, Commissioning Report Whichever Is Applicable. Page 10 Of 14 Run Date/Time: 10/07/2025 11:56:48Stores/Southern Rly Tender Document Tender No 16255011 Closing Date/Time 11/08/2025 14:30 15 Ca Certiï¬Cate Clause:- Tenderers Shall Normal Applicable To Yes Yes Not Allowed Provide A Certiï¬Cate From The Statutory All Bidders Auditor Or Cost Auditor Of The Company Or From A Practicing Cost Accountant /Chartered Account Giving The Percentage Of Local Content. The Bidder Shall Give Self-Certiï¬Cation For Local Content In The Quoted Item (Goods/Works/Services) At The Time Of Tendering. However, At The Time Of Execution Of The Project, For All Contract Above Inr 10 Crore, The Contractor/Supplier Shall Be Required To Give Local Content Certiï¬Cation Duly Certiï¬Ed By Cost/Chartered Accountant In Practice. For Cases Where It Is Not Possible To Provide Certiï¬Cation By Cost/Chartered Accountant At The Time Of Execution Of Project, The Supplier Shall Be Permitted To Provide The Certiï¬Cate For Local Content From Cost/Chartered Accountant After Completion Of The Contract, Within Time Limit Acceptable To The Procuring Entity. In Case The Contractor/Supplier Does Not Meet The Stipulated Local Content Requirement And The Category Of The Supplier Changes From Class-I To Class- Ii/Non-Local Or From Class-Ii To Non-Local, A Penalty Upto 10% Of The Contract Value May Be Imposed. However, Contract Once Awarded Shall Not Be Terminated On This Account. The Tenderer Shall Refer Para.16.1 Of Part.B Of Sr Tender Conditions Attached To This Tender Document. 16 The Tenderers Shall Submit A Copy Of Normal Applicable To Yes Yes Not Allowed Certiï¬Cate Stating That All Their Statements All Bidders / Documents Submitted Along With Bid Are True And Factual. Standard Format Of Certiï¬Cate To Be Submitted By The Bidder Is Enclosed As Annexure-I. Non-Submission Of Above Certiï¬Cate By The Bidder Shall Result In Summary Rejection Of His/Their Bid. It Shall Be Mandatorily Incumbent Upon The Tenderer To Identify, State And Submit The Supporting Documents Duly Self-Attested / Digitally Signed By Which They/ He Is Qualifying The Qualifying Criteria Mentioned In The Tender Document. It Will Not Be Obligatory On The Part Of Tender Committee / Accepting Authority To Scrutinize Beyond The Submitted Document Of Tenderer As Far As His Qualification For The Tender Is Concerned. 17 Please Enter The Percentage Of Local Normal Applicable To No Yes Allowed Content In The Material Being OffEred. All Bidders (Optional) Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. The Deï¬Nition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. General Instructions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading Page 11 Of 14 Run Date/Time: 10/07/2025 11:56:48Stores/Southern Rly Tender Document Tender No 16255011 Closing Date/Time 11/08/2025 14:30 1 Railway Is Not Bound To Accept The Lowest Normal Applicable To No No Not Allowed Or Any Tender Or To Assign Any Reason For All Bidders Doing So And Railway Reserves The Right To Accept/Cancel Any Tender In Respect Of The Whole Or Any Portion Of The Items Specified In The Schedule Annexed (Or Tender Schedule) And The Contractor Shall Be Required To Supply The Same At The Rate Quoted. 2 1. For Any Queries Against This Tender, Normal Applicable To No No Not Allowed Please Contact Cmm/M/Sr At 9003060762. All Bidders 2. Any Technical Clariï¬Cation Regarding Drawing/Speciï¬Cation Can Be Obtained From The Oï¬Ƒce Of The Pcme/Sr/Mas. Dy.Cme/Planning/Mas Mobile No. 9003060403 And Mail Id [email protected]. Drawing (S) / Speciï¬Cation (S) Can Also Be Obtained From The Above Oï¬Ƒce After Payment Requisite Cost. 3 Vendors May Please Note That Giving Normal Applicable To No No Not Allowed Intimation Regarding The Tender In Open All Bidders Tender Cases Or Giving Limited Tender Enquiry Does Not Guarantee The Suitability Of OffEr For Placement Of Purchase Order. Railway Reserve The Right To Place Purchase Order Subject To Fulï¬Lment Of Technical/Commercial Eligibility Conditions/Tender Conditions. 4 All Other Terms & Conditions As Per Irs Normal Applicable To No No Not Allowed Condition And Gcc. All Bidders Other Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 A) Inspection By Tpi (Third Party Normal Applicable To No No Not Allowed Inspection Agency). Firm To Indicate All Bidders Complete Works Address Where Inspection Will Be Conducted. The Tenderer Shall Refer Annexure 13 Of Sr Tender Conditions For Further Details Regarding Tpi Clause. Please Note That OffErs With Inspection/Visual Inspection By Tpi Against Test Certiï¬Cate/Guarantee Certiï¬Cate /Work Test Certiï¬Cate Is Liable To Be Ignored. For Further Details Regarding Tpi Clause, The Tenderer Shall Refer Annexure 13 Of Sr Tender Conditions Attached To This Tender Document. Alternatively, Tenderers May Please Refer The Attachment Tpi Conditions Enclosed To This Tender Document For Ready Reference Of Bidders Regarding Tpi Clause. B) Bidder Shall Indicate Place Of Inspection For Pre-Dispatch Inspection Duly Enclosing The Documentary Evidence. Note:- Any Request For Change In Place Of Inspection Shall Only Be Entertained With Documentary Evidence. 2 Marking : Manufacturer To Mark His Normal Applicable To Yes Yes Not Allowed Name And Date Of Manufacture As Per All Bidders Drawing, Wherever Indicated, Or At A Location Where It May Not Get Obliterated In Service On The Item Being Supplied By Them Against The Purchase Order. Supplies Received Without This Are Liable To Be Rejected By Consignee. Page 12 Of 14 Run Date/Time: 10/07/2025 11:56:48Stores/Southern Rly Tender Document Tender No 16255011 Closing Date/Time 11/08/2025 14:30 3 I/We Agree To Supply The Tendered Stores Normal Applicable To Yes Yes Not Allowed At The Rates Quoted By Me/Us In All Bidders Accordance With The Irs Conditions Of Contract, Sr Tender Conditions, Special And Other Conditions Speciï¬Ed In This Tender Document/ Attached With This Tender Document. 4 Machines Should Have Warranty Of 24 Normal Applicable To Yes Yes Not Allowed Months From Date Of Successful All Bidders Commissioning, Not From The Date Of Delivery As Mentioned Above In The Schedule Of Requirements. 5 No Developmental Order Will Be Placed For Normal Applicable To Yes Yes Not Allowed The Tendered Item. All Bidders 6 Post Warranty Camc Will Be Concluded By Normal Applicable To Yes Yes Not Allowed End-User Consignee At Their End After All Bidders Warranty Period, If Required. 7 Security Deposit Is To Be In Favour Of Normal Applicable To Yes Yes Not Allowed Sr.Dfm/Mas.Format Can Be Had From All Bidders Annexure 5 In The Document Tender Conditions For Electronic Tenders Uploaded. 8 Evaluation Will Be Group -Wise Normal Applicable To Yes Yes Not Allowed All Bidders Special Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Insurance Charges Should Be Quoted In Normal Applicable To No No Not Allowed Other Charges Column Against The All Bidders Particular Items. No Separate Line Has Been Provided For Insurance Charges. Technical-Compliances S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Bidders Must Submit Their Technical Bids Normal Applicable To Yes Yes Allowed As Per Format Annexure C And Other All Bidders (Mandatory) Annexures As Required In Bid Documents. Tenderers Are Required To Submit Complete Details Including Values, Write- Up, Drawings, Sketch, Brochure Etc. As Per Requirement Speciï¬Ed In Respective Clauses Mentioned Therein. In Case Of Incomplete / Sketchy Information, The Technical OffEr Being Incomplete Is Liable To Be Rejected. Tenderers Should Clearly Indicate Compliance. 6. Bidders Shall Confirm And Certify On The Behalf Of The Tenderer Including Its Constituents As Under: S.No. Description 1 I/We The Tenderer (S) Am/Are Signing This Document After Carefully Reading The Contents. 2 I/We The Tenderer(S) Also Accept All The Conditions Of The Tender And Have Signed All The Pages In Confirmation Thereof. I/We Hereby Declare That I/We Have Downloaded The Tender Documents From Indian Railway Website Www.Ireps.Gov.In . I/We Have Verified The Content Of The Document From The Website And There Is No Addition, No Deletion Or No Alteration To The 3 Content Of The Tender Document. In Case Of Any Discrepancy Noticed At Any Stage I.E. Evaluation Of Tenders, Execution Of Contract Or Payment, The Master Copy Available With The Railway Administration Shall Be Final And Binding Upon Me/Us. I/We Declare And Certify That I/We Have Not Made Any Misleading Or False Representation In The Forms, Statements And 4 Attachments In Proof Of The Qualification Requirements. I/We Also Understand That My/Our Offer Will Be Evaluated Based On The Documents/Credentials Submitted Along With The Offer 5 And Same Shall Be Binding Upon Me/Us. I/We Declare That The Information And Documents Submitted Along With The Tender By Me/Us Are Correct And I/We Are Fully 6 Responsible For The Correctness Of The Information And Documents, Submitted By Us. I/We Certify That I/We The Tenderer(S) Is/Are Not Blacklisted Or Debarred By Railways Or Any Other Ministry / Department Of 7 Govt. Of India From Participation In Tender On The Date Of Submission Of Bids, Either In Individual Capacity Or As A Huf/ Member Of The Partnership Firm/Llp/Jv/Society/Trust. Page 13 Of 14 Run Date/Time: 10/07/2025 11:56:48Stores/Southern Rly Tender Document Tender No 16255011 Closing Date/Time 11/08/2025 14:30 I/We Understand That If The Contents Of The Certificate Submitted By Us Are Found To Be Forged/False At Any Time During Process For Evaluation Of Tenders, It Shall Lead To Forfeiture Of The Emd And May Also Lead To Any Other Action Provided In The 8 Contract Including Banning Of Business For A Period Of Upto Two Year. Further, I/We And All My/Our Constituents Understand That My/Our Offer Shall Be Summarily Rejected. I/We Also Understand That If The Contents Of The Certificate Submitted By Us Are Found To Be False/Forged At Any Time After The 9 Award Of The Contract, It Will Lead To Termination Of The Contract, Along With Forfeiture Of Security Deposit And May Also Lead To Any Other Action Provided In The Contract Including Banning Of Business For A Period Of Upto Two Year. I/We Have Read The Clause Regarding Restriction On Procurement From A Bidder Of A Country Which Shares A Land Border With India And Certify That I Am/We Are Not From Such A Country Or, If From Such A Country, Have Been Registered With The 10 Competent Authority. I/We Hereby Certify That I/We Fulfil All The Requirements In This Regard And Am/Are Eligible To Be Considered (Evidence Of Valid Registration By The Competent Authority Is Enclosed) 7. Documents Attached With Tender S.No. Document Name Document Description 1 5446564.Pdf Irs Conditions 2 5446567.Pdf Sr Tender Conditions 3 5446589.Pdf Tpi Guidelines 4 5463672.Pdf Delivery Schedule Chart 5 5446667.Pdf Technical Specification 6 5453473.Pdf Annexure-I 7 5446617.Pdf Special Conditions Of Tender 7. Responsiveness S.No. Description 1 Validity Of Offer:-120 Days, No Deviation From The Offer Validity Period Stipulated In The Tender Is Permitted. I/We Have Carefully Gone Through The Irs Conditions Of Contract (Included And Uploaded Along With The Bid Document) Particularly Para 2500 Pertaining To Code Of Integrity, Misdemeanor And Penalties. I/We Hereby Certify That No Other Concerns Or Aï¬Ƒliates (Such As Having Common Partner/Director/Promoter/Owner/Holding Company Decision Control Etc.) Have Participated In This Tender Which Can Give Rise To A ConflIct Of Interest Or Fall Under Anti-Competitive Practices. We Understand That The 2 OffErs Of All Such Sister Concerns Including Ours Are Liable To Be Rejected As Per Relevant Provisions Of Irs Terms And Conditions. I/We, Aï¬Ƒrm That We Shall Abide By The Code Of Integrity In General, With Speciï¬C Reference To ConflIct Of Interest [Para 2502 (E)], Anti Competitive Practices [Para 2502(C)] And Obligation To Proactive Disclosures [Para 2503]. I/We Understand That We Are Fully Responsible For The Above Declaration And It Shall Not Be The Railways Responsibility To Verify The Same. I/We Are Aware That We Shall Be Liable For All Consequences Of Violation Of Code Of Integrity, If Detected, At Any Stage. The Tenderers In Their Bid Shall Indicate The Details Of Their Gst Jurisdictional Assessing Officers (Designation, Address & Email Id). In Case Of A Contract Award, A Copy Of Purchase Order Shall Be Immediately Forwarded By Purchaser To The Gst Jurisdictional Assessing Officer Mentioned In Tenderers Bid This Tender Complies With Public Procurement Policy (Make In India) Order 2017, Dated 15/06/2017, Issued By Department Of Industrial Promotion And Policy, Ministry Of Commerce, Circulated Vide Railway Board Letter No. 2015/Rs(G)/779/5 Dated 03/08/2017 And 27/12/2017 And Amendments/ Revisions Thereof. As A Tender Inviting Authority, The Undersigned Has Ensured That The Issue Of This Tender Does Not Violate Provisions Of Gfr Regarding Procurement Through Gem. Digitally Signed By Dy.Cmm/Traction ( Irene Neethu Singh Densingh ) , Spares For 2Years Normal Operation And Maintenance With Price Breakup Of Individual Items A S Per Clause 3 Of Part-1 (Annexure-B) [ Warranty Period: 30 Months After The Date Of Delivery ] ] , Cost Of Installation & Commissioning Of Equipment ] At (Location) Sse/Bbq, Sr Tamil Nadu 1.00 Numbers
Contract Date: Apr 22, 2026 Contract Value : 2.03 Crore
Government Departments No of Bidders 1
13.
Educational and Research Institute #10625357 Price Bid
Supply Of Instruments / Equipments=1.00 Flow Meter 1.01 Size : 40- 100 Mm 1.02 Flow Range : 25- 250Ml / Mnt 1.03 Volume Per Revolution : 0.309L 1.04 Greatest Pressure : 2.5 Mpa 1.05 Accuracy : ±0.2% 1.06 Repeatability : ≤0.05% 1.07 Standard Unit : Rise 2.00 Co2 Probe 2.01 Exact Application : Measurement Of Dissolved Co2 In Microalgae Culture 2.02 Measurement Range : 10 To 1000 Mbar Co2 2.03 Accuracy : ± ( 10 % Of The Reading + 10 Mbar ) 2.04 Operating Temperature :0 To 60 °C ( 32 To 140 °F ) 2.05 Mechanical Temperature Resistance : – 20 To 130°C ( – 4 To 266 °F ) 2.06 Operating Pressure : 0.2 To 2 Bar ( 3 To 30 Psia ) 2.07 Mechanical Pressure Resistance Max. : 3 Bar ( 42 Psia ) At 25 °C ( 77 °F ) 2.08 Response Time T90 : At 25 °C ( 77 °F ) < 120S 2.09 Steam Sterilizable And Autoclavable : Yes 2.10 Cable Connection : Ak 9 2.11 O2 Selective Membrane Material : Ptfe / Silicone 2.12 Shaft Diameter : 12 Mm 2.13 Available Lengths : 220- 320 Mm 2.14 Distance Between Sensor And Transmitter : 40Mm 2.15 Blind Transmitter : Ok 3.00 Palletizer Machine 3.01 Body Material : Hardened Mild Steel 3.02 Output Capacity : 20 To 50 Kg / Hr 3.03 Pallete Size Die : 8Mm To 10Mm 3.04 Motor Power Capacity : 3 To 5 Hp 3.05 Roller : 1 Set 3.06 Palletizer Mill Weight : 90 Kg 3.07 Palletizer Mill Size ( H X L X W ) : 36 X 48 X 24 3.08 Movement Of Palletizer Mill : Trolley On Wheels 3.09 Shape Of Hopper : Round 4.00 Shredder Machine 4.01 Cutting Mechanism : Twin Shaft 4.02 Shred Chamber ( Mm ) : 310×310 4.03 Shred Size ( Mm ) : 8×50-100 4.04 Shred Capacity : 200-300 Kg / Hr 4.05 Voltage : 415V 4.06 Power : 3 Hp 4.07 Hopper Volume ( Liters ) : 60 L 4.08 Waste Volume ( Liters ) : 180 L 4.09 Weight : 275 Kg 4.10 Running Cycle : Continuous 5.00 Soxhlet Appratus 5.01 Automatic Pc Compatible Solvent Extraction System ( Digital ) 5.02 • Fully Automatic Programmable Six Place Auto Sequencing Pc Compatible Solvent Extraction System 5.03 • Tft Graphic Touch Screen Display With Unique Wireless Mouse To Operate Directly Without Connecting To Pc. 5.04 • Icons To Represent Output Of Heating Process In Touch Screen Display 5.05 • Selectable Programs ( Customizable ) : Integrated Auto Sequencing Features With Intelligent Memory Programs Minimum 50 Programme With 10 Sequencing Steps With Inbuilt Datagger With User Id, Channel Name, Scan Rate, File Browse Feature To Download Stored Data With Inbuilt Software For Usable Csv And Excel Format 5.06 • Data Logger With Real Time Clock With Memory Stick For Data Storage With Separate Port In Mother Board Apart From Pc Port 5.07 • The Advanced Superior Pc Chart Software Performs Live Graphical Representation Of Time / Temperature Gradient On Touch Screen Display Directly. 5.08 • Temperature Range: 35°C ( Ambient ) To 300°C, Temperature Accuracy / Precision : + 0.5° C 5.09 • Temperature Controller Should Be Isolated Separately In A Control Tower To Protect Electronics From Solvent Area & Heat Zone For Safe Operation 5.10 • Measuring Range: 0.1 To 100% Fat / Oil 5.11 • Repeatability: + 1% Or Better 5.12 • Speed Of Extraction: 40 To 60 Minutes Depending On Application 5.13 • Auto Phase Change Of Extraction Includes Boiling, Condensation, Rinsing, Solvent Recovery & Predrying 5.14 • Inbuilt Airpump, Ss Manifold, Automatic Collection Of Recovered Solvent, Versatile Sizes Of Thimble ( Extra Thimble Should Be Provided ) 5.15 • Upgradeable Remote Control Module For Wireless Data Monitoring, Control And Transfer To Pc At A Distance Of 5-10 Feet. The Entire Display Screen Of Controller Should Wirelessly Appear In The Pc / Laptop Of User, To Monitor & Control From His Work Table. 5.16 • Electrical Requirement:230V / 50Hz. Ac Mains. 5.17 Refrigerated Water Cooling Circulating System 5.18 • Refrigerated Water Cooling Circulating System With Digital Display Of Temperature, 5.19 • Microprocessor Based Pid Temp. Controller, Temperature Range: 10°Cto 20ºc. 5.20 • Inbuilt Safety Features With Ce Certification To Fulfil All Statutory Requirement Of Good Laboratory Practice. Auto Over Temperature Protection / Auto Error Indication / Auto Sensor Break Protection, Over Load Protection. 5.21 • Ss Tank, Submergible Pump For Recirculation, Ms Powder Coating Housing 5.22 • The Instrument Should Be Approved Registered Brand & Shall Strictly Confirm To The Specifications With Relevant Brochure & Photograph As Per Specification. 6.00 Recirculating Chiller 6.01 Temperature Range: -10~100ºc 6.02 Precision:±0.2 6.03 Cooling Capacity At 20°C -800W 6.04 Interior Dimensions:150X160x150mm 6.05 Chamber Volume:4.5L 6.06 Electrical Requirement:220V 50Hz 6.07 Pump Flux:8L / Min 6.08 Power Consumption : 2300W 6.09 Microprocessor Temperature Controller 6.10 Audible And Visible Alarm For Temperature And Water Level 6.11 R134a Refrigerant, Imported Compressor With Interface To External Water Bath 6.12 Rs485 Connector To Connect Computer To Record The Parameters And The Variations Of Temperature. 7.00 Portable Gas Analyser ( Syn-Gas ) 7.01 Method Of Detection : Ndir Infrared Sensor For Co, Co2 And Ch4 Electrochemical Sensor For O2 & H2 7.02 Ranges Available O2 0-25.0%, 0-50.0%, 0-100.0% Co 0-10.0%, 0-50.0%, 0-100.0% Co2 0-10.0%, 0-50.0%, 0-100.0% Ch4 0-50.0%, 0-100.0% H2 0-5.0% 7.03 Resolution : 0.1% For All Gases 7.04 Accuracy & Repeatability : ± 2% Of Reading For All Gases 7.05 Drift : Less Than 2% Of Full Scale Per Month 7.06 Response Time ( T-90 ) : 20-30 Seconds To 90% Step Change 7.07 Ambient Temperature Range : 4 To 50°C 7.08 Power : 12V / 24V Dc Adaptor 7.09 Output Options : Rs 232 Interface For Data Logging 8.00 Sieve Shaker With Sieve 8.01 Heavy Duty ( Improved Model ) For 8 Inch Test Sieve 8.02 The Sieve Shaker Is Durable Constructed And Is Run By ¼ H.P. Electric Motor 220 Volts A.C. Through Reduction Gear. 8.03 Designed To Carry Upto 6 / 7 Test Sieve Of 200Mm Dia ( 8 Inch ) With One Set Lid & Pan. 8.04 It Produces Circular And Hammering Motion Is Given At Top. 8.05 It Reproduce Circular ( Revolution Approx.: 280 To 320 R.P.M And Tapping Approx.: 140 To 160 R.P.M. 8.06 No Foundation Required. 8.07 7 Nos. Of Test Sieve ( Dia 8 Inch ) Made-Up Of Brass With Different Sizes Such As 106 Μm, 150 Μm, 212 Μm, 250 Μm, 300 Μm, 500 Μm, 850Μm. 8.09 One Set Lid And Pan With Above Specification. 9.00 Moisture Analyser 9.01 Max. Capacity : 50 G 9.02 Readability ( Weight ) : 0.1 Mg 9.03 Readability Moisture : 0.0001% 9.04 Repeatability ( Sample 2G ) ( Sd ) : 0.05% 9.05 Repeatability ( Sample 10G ) ( Sd ) : 0.02% 9.06 Units Of Measurements : %M, %D, %R ( Ratio ) , Gm / Lt, %M Atro, %D Atro 9.07 Statistics : Method Wise For Each Individual 40 Methods Or Batch Wise For Each Individual 100 Batches For Last 999 Results 9.08 Technology : Infra Red Halogen 9.09 Temperature Range : Max. To 175°C ( Optional To 250ºc ) 9.10 Temperature Increment : Interval 1ºc 9.11 Heating Profile : Standard, Gentle, Rapid, Steps, High Temperature 9.12 Switch Off Criteria : Auto, Manual 9.13 Auto Method Development : Intelligent 9.14 Method Memory : 40 And Batch Memory : 100 9.15 Method Designation : Alpha Numeric 9.16 Serial Number : Yes 9.17 Compile : Yes ( Method Linking ) 9.18 Operating Temperature : 15ºc To 35ºc 9.19 Display : Graphical Lcd Display With Led Backlite 10.00 Filter Vacuum Pump 10.01 Wetted Parts 304 Stainless Steel, Free Air Capacity ( Lpm ) ≥28 Max Flow Rate ( Cfm ) ≥ 0.99 Max Flow Rate ( Litters / Min ) ≥28 Max Pressure ( Psi ) ≥ 60 Max Pressure ( Bar ) ≥4.14 Max Vacuum ( Mbar ) ≥ 500 Noise Level ( Db ) ≥ 68 Port Size ¼ Npt ( F ) 3 / 4 Hose Barb On Gauges Noise Level : 50.00 Db 10.02 Filtration Unit 10.03 Material Type: Glass Diameter: 50Mm Capacity: Upper Chamber-500 Ml, 1000Ml, Lower Chamber-500Ml Sintered Crucible Nylon 66 Membrane & Filter, Filterpaper Nontoxic, Unbreakable Polysulfone Funnel Is Used In Microbial And Particulate Analysis. Funnels Do Not Leak After Repeated Autoclaving Removal Membrane Support Plate Is Designed To Provide Maximum Flow Rate And Through Put. Filtration Assembly Made Of Borosilicate Glass With Fritted Glass Filter Base The Base Design Has An Integral Vacuum Connection Located Above The Filtrate Drip To Prevent Contamination Of The Vacuum Line From Droplets The Filtration Base Has A Silicon Stopper, Anodized Aluminum Spring Clamp Facilitates Analysis Of Particulate Or Biological Contamination Of Vacuum Filtering Liquid The Scaled Funnels Simplify Dosing And Analysis 11.00 Lambda 365 Double Beam Uv Spectrophotometer Compatible Accessories Kit 11.01 50 Mm Trans / Reflect Sphere High Sens Used For Measuring The Diffuse Reflectance ( Sce ) , Total Transmittance, Diffuse Transmittance And Performing Color Analysis. It Has A Spectral Range Of 230-1100 Nm ( Uv And Visible ) . Its Port Size Is 10.00 Mm And The Spectral Bandwidth Is 20Nm. 11.02 Powder Sampling Kit
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 9
14.
Banking and Finance #10607564 Price Bid
E-Tender For Procurement Of Equipments For Siep -1 Pre- Vocational Unit 2 Children Wall Bar -n(•tThe Size should be : 85*52*168cmn•tMust be Use full for children to do standing and sitting training with the help of wall bars and muscle strength training as well as trunks traction and extension training.) 3 Children PT Stool(adjustable) -n(•tMust be use full for Used for children PT training.n•tIt must have Wheelsn•tIt should have Blue Leather Sitting) 4 Finger Correcting Board -n(•tUsed to correct fingers flection contracture and adduction malformation.n•tIt should have 4 holes) 5 Finger Correcting Board(with universal wheel) -n(•tUsed to correct fingers flection contracture and adduction malformation.n•tIt should have 3 holesn•tIt Should have 3 or 4 Wheels) 6 Hydraulic children step trainer -n(•tSize Must be: 70*56*97cmn•tWeight not more than: 29kgn•tUse full for lower limbs range of motion and muscle power training.) 7 Training Quoit -n(•tIt must be Use full for hand-eye coordination and perceptionn•tIt must be Use full Cognition training.) 8 Word cognitive puzzle –n(•tWeight not more than : 3.3Kgn•tMaterial must be: wooden) 9 Cognition Toys – n(•tSize should be: 30*30*30cmn•tWeight not more than: 8.7kgn•tShape must contain following:n-tCube 5pcsn-tCylinder 5pcsn-tTriangular 5pcsn-tCuboid 5pcsn•tIt must be use full for perception function training.) 10 Intelligence develop assembly – n(Size must be: 32.2*28.7*23.5cm) 11 PHYSIO-OCCUPATIONAL THERAPY UNIT 12 Treadmill- 2HP Noiseless AC motor 13 Short wave diathermy- 500W with valve 14 Bolsters of different sizes 15 Puzzle - Body parts with two facial expressions with box, Animal, Birds, fruits, transports, Different shapes 16 Shoulder CPM 17 Lower extremity CPM 18 CP chair 19 Static cycle 20 Bed cycle 21 weighing scale 22 texture fruit tree 23 Ball pool (48X 48) 24 perdue peg board 25 exercise mats - 6X3 26 exercise frame - rope mess, pip ladder and rock climbing board 27 Trampoline (48 Inch) 28 Quadriceps Table with detachable backrest 29 Stethoscope 30 blood pressure appratus 31 Goniometer – 180 & 360 degree 32 Electronic stopwatch 33 Digital weighting machine 34 Treatment trolley 35 Stainless steel stools 36 Tables 37 Chairs 38 Waiting chairs 39 Cupboards 40 Computer 41 Printer & scanner 42 Muscle stimulator Combo- with Current -Galvanic, Interrupted Galvanic, Faradic, Surged Faradic and TENS 43 Micro control 4 channel tens 44 Weight cuff- 1/4 kg, 1/2 Kg, 1 Kg, 1.5 kg -n(•tStrengthens weak muscles through load resisting exercises of both upper and lower limbs. n•tLead shots filled cuff is double sewn and had long wrap around straps to hold weight cuff securely in Place. n•tA full set consists of 4 color coded cuffs i.e. Capacity: 250 gm, 500 gm, 1 kg, 1.50 kg) 45 Thera band- different colors and ranges – n(•tTheraBand Rubber Latex Less Bands should be supplied with 5 feet length, 4-inch width of different colour (Yellow, Red, Green, Blue, Black) - Set of 5n•tIt should be Latex Less, No Scent, No Powdern•tColour-coded Progressive Resistance system should allow users to recognize improvement as it happens – when the patient grows stronger they can move up to the next color, for strength training and physical therapy programs. Colour-coded levels should be increasing in difficulty from Yellow to Black) 46 Thera putty with different colors & ranges – n(The system should have following parameters:n•tColours options : Tan, Yellow, Red, Green, Blue, Greyn•tWeight must be: 100grams eachnHigh Resistance Level)n 47 Portable shoulder exerciser with pronation supination arrangement 48 Grip exerciser 49 Hand Gym Kit Board –n(Laminated exercise boards with storage drawer, have several holes to fix Pegs and springs. The unit permits active flexion and extension exercises of the finger and grip.nSpecification:nHand Gymkit Board consists, One finger Disc, One Roller, Three Spring loaded Knobes, 3 pegs to support finger and 3 Sets of Springs of different tensions) 50 Wrist roll -n(The unit should have following parameters:n•tOne piece SS roll with three different diameters i.e. 30mm, 40mm and 50mm to be fitted on a laminated board n•tBoard size: 25cm x 80cm long with adjustable friction control mechanismn•tControllable from zero to maximum for flexion and extension exercises of wrist and forearm) 51 Rope pulley handle set –n(Shoulder Pulley Unit with rope adjustment system (Wall Mounting)n•tShoulder Pulley unit should provide exercises of the Elbow and shoulder. n•tTubular steel constructed unit should come with Pulleys, Nylon Rope, Handles and Wall fixing frame.n•tPulleys: Two, Nylon pulley n•tHandles: Two, spring steel wire handle with plastic grip.n Rope/Cord: Interwoven Nylon cord of suitable length.) 52 Upper extremity work station -n(should have facility of peg board, pinch tree, pipe assemble unit PVC, 25 holes peg board, multi shape peg board, hand tool test frame, finger dexterity board, door latch board, dressing board set, shoulder deduction ladder, bilateral shoulder ladder, hand exercise board Velcro, hand gym board, trolley with lock) 53 Vestibulator with facility of Platform swing, flexion disc, frog swing, Lycra swing , Bolster swing rectangular 54 Vestibular board - 3.6 X 2.6 X 7 – n(Vestibular Board should be of large size for rocking the body on board stimulates balance control with Vestibular Responses. nThe top should be of thickly upholstered and covered with rexine and washable fabric cover) 55 Scooter board – n(•tBoard with 4 Wheels (90cm Long x 30cm wide): It should help the child to learn body control, shifting weight, changing directions and maintain balance. Wooden Scooter Board with foam padded top should be used in a sitting, kneeling or prone position for developing strength of the upper and lower extremities.n•tIt should have ply-wood base, supported on 25mm x 25mm angular iron frame.n•tIt should have high density Foam padded top is 25mm thick & to be covered with nylon fabric in two Colours.n•tIt should be fitted with (4) four, 50mm dia castors.n•tBoard Size should be: 90cm long x 30cm wide) 56 Wedges of different sizes – n(•tWedges with set of four size: A: 15x60x70cm; B: 20x60x70cm; C: 25x60x70cm; D: 30x60x70cm) 57 Post box with 25 plates -n(•tSorting, Matching & Posting Box unit should measure an individual basic level of function in the area of colour identification and Eye-hand co-ordination.n•tConstruction of the box should be Laminated Wooden with five multicolour plastic plates fixed at the top with five Slots to Post matching colour plates there in.n•tIt should have 25 well-polished plastics plates in 5 different colors to sort, match and post.n•tBox should come with five compartments to be fitted with sliding door to store plates and also works as posting box.n•tIt should be Natural polished finish with laminated tops & door.) 58 Door latch board –n (The frame set provides learning opportunity and progressive development of dexterity. nWith six laminated doors, opening in different directions. nEach door opens into a shelf where a reward or toy can be kept. nCommon hardware of different designs, generally used in the home is used to familiarize Patient. Size of laminated unit is 26x18x5 deep.)nnn 59 Floor seater – n(•tFloor sitter should be useful for the child who cannot sit up on his own, and who needs his shoulders and upper trunk supported.n•tThese Floor Sitters must offer support in seating a child at floor level. This must allow the child to be independent, with hands free for play, while maintaining optimal erect trunk alignment.n•tConstruction: It should have Wooden Corner Seat, with broad base that help to prevent tipping.n•tSeat & Back should have Sitter with foam padded Seat, Sides and Back support.n•tAccessories should include abductor block, hip positioning belt & removable tray should be integral part of the floor sitter.nSeater should be finished in natural wood polish. Seat & Back to be covered with multi-colour Rexene) 60 Stand in table with Standing Metal Frame – n(Basic standing frame, with comfortably supports weight- bearing parts of the body. nIt Helps to prevent atrophy of leg muscles, improves range of motion, helps improve circulation, lessens muscle spasms and contractions n Three straps should be provided for heel, ankle and pelvic support) 61 Tunnel – n(•tCrawling tunnel Non-folding, Aluminum sheet with windows on sides and inner area padded with foam should be suitable hospitals with multiple patients.n•tTunnel Set of three parts with windows on sides are padded with soft Eva foam inside. n•tIt should be made in three parts of 90cm long each, all the three tunnels should be fixed together to make a single tunnel of 2.75 meter length.n•tInside Diameter should be 50cm dia.) 62 Treatment Plinth– 63 Wooden blocks of different heights- set of 6– 64 Peanut ball– n(•tIt can help you achieve muscle and tension release for all parts of the body.n•tPeanut shape design, convenient to use.n•tSuitable for yoga, Pilates, etc., help you has better fitness effect.n•tMade of durable PVC material for long term using.n•tFeatures: Peanut Shape, Inflatable, Explosion-proof, Durable, Fitness Tooln•tSize: 45cm x 95cm/17.72 x 37.40 (Approx.) 65 Staircase– n(•tStep arrangement: FOUR 15cm steps on one side, leading to platform size 75cm x 75cm. First step moves into the second to make it a bus step of 30cm height. 7.5cm steps on the other side. Steps are 75cm wide & 23cm deep (approx.).n•tFitted with 2 sets of handrails at different height to accommodate Adults & children. n•tSteps and Platform are made of commercial board of 12 mm thickness & covered with non-slip matting. n•tSides & Supporting frame of Steps are made of commercial board of 18mm thickness with hardwood reinforcement. n•tHand Rails & supporting bars are made of solid hardwood. Stairs finished natural) 66 Parallel bars with platform-n(•tParallel Bars should have adjustable Height & Width with PVC. n•tOuter uprights of thick steel tubing0 of 50mm dia. with Powder coating finish. n•tPlatform: Tubular steel reinforced platform with incline on both ends & is covered with non-slip matting. n•tLength: about 10feet n•tAdjustments: Should be easily done by means of setting Pins at the required holes & should be stabilized by tightening the screws. n•tFinish: Working Parts are with powder coated / chrome plated finish & wooden parts with Natural polish finish.n•tCovered with non-slip matting.n•tPostural Training Mirror: Mirror should be of size 175cm x 53cm (approx.) and should be protected by hardwood polished frame with back covered by ply board. n•tStand: Mirror should be fitted on tubular stand with powder coated finish) 67 Suspension framenSuspension Frame (with Accessories) without Bedn(•tSuspension Frame set for complete Suspension with Slings & Ropes. n•tTop Mesh should facilitate suspension at any desired point in relation to the patient and as required in each individual case. n•tConstruction: Tubular steel frame with 6mm thick Rod-mesh at Top and on Upper Sides. n•tLegs should be fitted With Rubber/PVC Shoes.n•tSizes: Overall sizes 210cm long x 110cm (approx.) wide at the base, 50cm (approx.) wide at the top & 190cm (approx.) high.) 68 Stability Disc–n(It should have balance Cushion - an Inflatable cushion that must come with 2 different surfaces that introduce an element of stability to a workout, must be ideal for both balance and core training. The balance cushion must allow users to exercise and working to stay balance; with constant micro movements that will strengthen the core muscles and improve postures. It should have the benefits of using Balance Cushion. Strengthen core muscles and improve postures required. Diameter- 33 cm required. Colors required: - Lime Green(Spiky Surface), Blueberry (Smooth Surface)) 69 Vibrator (with 6 attachments) – n(•tThe unit should be able to vibrate against the body and stimulate the nerves for a relaxing feeling.n•tIt should give horizontal circular motion which effectively relieves muscular fatigue and pain.n•tIt should have following two speeds:n•tHigh with rpm 3500n•tLow with rpm 1500n•tIt should have cooling system for continuous use so that massage can be done for long time.n•tIt should have durable body for professional use.n•tIt should be heavy duty and the weight should be above 2.5 kg.nIt should have two handles for applying pressure on the chest/muscle group.) 70 Ramp and curb– n(CURBS AND RAMP (without handrails) Hardwood constructed training set consists of ONE ramp and THREE nested curbs stored below the ramp. The ramp graduates from 20mm to 200mm and is 84 X 44. The curbs are 40x 40x 6, 36x 36x 4 and 32x 32x 2 respectively. Natural wood finish with anti-slip safety mats on ramp and curbs without handrails) 71 Balls for ball pool– n(It should have brightly colored balls encourage movement plus give child visual & tactile feed-back and support. * Size of ball should be of 7cm or 8cm dia with different colors) 72 Ankle exerciser-n(Painted aluminum boot with strap to hold the foot is mounted ona laminated base with Stainless steel sheet bracket having two springs for ankle (Dorsi and Plantar flexion) exercises. nResistance can be increased further by tightening springs nut. nDegree of flexion can be measured and recorded) 73 Walker with 4 castors - non folding-n(Walking Aid Folding & Adjustable HeightnLight weight, painted aluminum tubular construction, folds easily and quickly. Height of frame is adjustable from 75 c.m. to 90 c.m. by slipping locking pins in proper notch. Fitted with soft PVC hand grips and shoes) 74 Circle balance disc-n(•tThe board should have encourages Balance and Neuromuscular Re-education, Rhythm, Coordination and Vestibular responses. Children can use it in kneeling or standing position.n•tTop Diameter should be 51cm round, cushioned top covered with rexine.n•tBase must be fitted with semi-circular base, 60mm height.n Hand-Holds must be of Two, Side holds to be provided for stability) 75 Board for lower extremity - standing exercise 76 Foot placement ladder– n(•tIt should be useful in early walking with balance training. n•tShould be of wooden floor ladder with adjustable dividers, n•tShould offer various walking patterns. n•tSteps should be of equal size and alternately placed for right-left progression.n•tBeams & Dividers should be made of Teak-wood with size 96 long x 27 wide.n•tBeams should be finished in natural wood. n Adjustable 16 Divider bars should be finished in different enamel colours) 77 Graded spring set– n(•tSuspension Springs should be made out of best steel wire, with chrome plated finish; the rope is fitted in the spring to avoid overstretching.n•tTension of the springs must be: A. 5 kg-7kg., B.8kg-10kg., C. 12Kg-15kg. D. 18kg-20kg., E. 22kg-25kg.n•tSet should consist of ONE spring each (A+B+C+D+E) with S hooks.n•tIt should be Suitable for Extension, Flexion and Suspension activities.n It should be Full Set of 5 springs) 78 Long Handle thick grip spoons-n(•tIt should have stainless Steel long handled spoons, with smooth spoon tips.n•tThe spoons must help child/baby to master fine motor skills.n•tThese spoons must be easy to clean and maintain.n It should have set of 05 pieces) 79 Tactile balls for grip-n(•tIt should have Bumpy sensation when these are squeeze by hands. Knobby surfaces and bright colours should promote sensory and tactile exploration and it must help develop fine motor skillsn•tIt should have soft and squeezable material easy for small hands to grab and promote hand-eye coordinationn•tIt should have soft, knobby surface to provide massage stimulation for little ones. n•tIt should be supplied with Set which includes (06) toys in assorted colours and shapes (Round, Square, Cone, Pyramid & Rectangle etc.).n•tIt should be BPA, Latex and Phthalate freen•tIt should be helpful to build and define childs gross motor skillsn It must be Capture childrens interests and Hearts) 80 Lotca battery test-n(•tIt should have the plan to provide the appropriate therapy. n•tThe DLOTCA (Dynamic Lowenstein Occupational Therapy Cognitive Assessment) battery must design to offer this type of critical assessment. n•tThe DLOTCA battery must measure the cognitive abilities of those with neurological impairments or injuries.n•tIt should have a set of minimum 28 sub-tests analyses the cognitive areas pertaining to: Orientation, Awareness, Spatial Perception, Visual Perception, Vasomotor Construction, Praxis and Thinking Operations. n•tThe DLOCTA should be supplied with full kit with the following Components: Instruction manual authored by top leaders in the occupational therapy field Test booklets and score sheets Card and shape sets for various sub-tests.nPegs and peg-boards must have followings…n•tTen 1 x 1 natural wood blocks.n•tFour 1 x 1 blue wood blocks.n•tTwo 1 x 1 orange wood blocks.n•tThree 1 x 1 green wood blocks.n•tOne 1 x 1 yellow wood block.n•tButter-fly puzzle. Photo book.n•tSafety scissors.n•tPencil, paper and envelope.n•tCarrying bag.n•tThe kit is compact for easy transportation weighingn•t8.5 pounds and measuring 4.5 x 10.5 x 16.5 inches.) 81 Minnesota test-n(•tIt should measure manual dexterity of the Arm and Hand for manipulative work, utilizing a broad range of shoulder motion.n•tTest should involve Turning, Placing or moving the discs in a prescribed manner. Requires unilateral & bilateral movements.n•tTests should include 60 two colored plastic cylinders, plastic board, record forms and carrying case) 82 Exercise frame - rope mess, pip ladder and rock climbing board 83 Tilt Table– 84 Wobble Board– n(•tAnti-Slip Wooden Wobble Balance Board for Fitness & Training Rehabilitation Exercisen•tHigh Quality Material And Durable: Consisting of quality wood and tough plastic base, highn•tStrength, enduring for daily training.n•tStrength Stability: The balance board also enhancing the muscle strength of waist and n•tAbdomen, beautifying the hip muscle.n•tRotatable: The can support 360 degree horizontal rotating when placing it on flat ground.n•tKeep Balance: Stimulating posture conditioning, strengthening the stability of the vestibular.n•tOrgans and improving the bodys balance.n•tWidely Usage: The balance board is suitable to be used for hemiplegia stroke and other post-balance rehabilitation training.n•tWarranty not applicable for this product) 85 Cryo Therapy Unit–n(•tTherapeutic device should be capable to produce a real deep thermal shock effect.n•tThe thermal shock is a physiological stress should produce by sudden or rapid temperature variations in the local tissues.n•tThe system should not only allow performing cry therapy or hyperthermia separately but also and above all thermal shock therapy in a dynamic and controlled way.n•tHyperthermia, transdermal cryothermica and thermal shock can be modulated in depth and intensity.n•tShould be equipped with a treatment head based on the technology of Peltier cells capable of generating heat or subtracting heat in a range from +45°C to -18°C.n•tA special sensor should transmit the target temperature and the local body temperature should appears on the LCD screen in real-time to inform the operator how the therapy is acting on the patient.n•tAll the functions should be visualized on a large color LCD in addition to the usual and traditional keys and buttons,n•tShould be possible to adjust every parameter on the touch screen.n•tThe versatile Windows CE operating system should ensure possible upgrading.n•tShould have availability of a wide range of preset protocols with body maps. n•tThe screen should show the body parts to be treated and the unit should suggest the parameter values to set after selection of pathology is chosenn•tShould have free memories for entering customized protocols.n•tTemperature: from +45°C to -18°Cn•tShould have Colour touch screen displayn•tCompact unit with dimensions: 41 x 42 x 18 cm or smallern•tLight Weight: Not more than 9 kgn•tSafety class: class I type B, class IIa) 86 Electrical traction with 3 fold Bed-n(•tThe traction unit should consist of set of mechanisms for relieving pressure on the skeletal system.n•tIt should have a large LCD display panel showing all parameters.n•tIt should have at least 8 different modes (a) Intermittent (b) Static (c) Progressive/ intermittent (d) Progressive/ Static (e) Progressive/ Regressive (f) Cyclic /Intermittent (g) Cyclic / Static (h) Cyclic tn•tIt should consist of automatic calibration of traction force to maintain correct traction force.n•tIt should have high/low force range of 1-90 kg/0-89 kg.n•tIt should be possible to apply cervical as well as lumber traction with the machine.n•tIt should have adjustable hold and rest time range of 0 –99 sec.n•tIt should have selectable ramp steps of 2-8 steps with selectable pause time of 2-20 sec. for each step.n•tIt should have 5 different pulling speeds.n•tIt should have memories storage of at least 30 treatment patterns.n•tIt should have timer of 90 minutes.n•tIt should be supplied with Fixed Height Traction bed (Indigenous).n•tShould be supplied complete with Traction Unit, Cervical Harness ,Pelvic Harness, Spreader Bar, Patient Switch) 87 Treatment couch– n(HIGH-LOW TREATMENT TABLE (Electrical)nElectric, variable height, three section table is suitable for all treatments, including manipulation both ends elevate so that the back or legs can be raised without turning the patient. One ends also lower -20 deg. for some postural drainage & manipulation techniques and more comfortable sitting. The foam padded top is 195 cm long and 70 cm wide. Table height is adjustable from 50 cm to 90 cm. Frame-work in light blue oven baked finished) 88 Pain Relief System -n(•tCombination therapy unit with Heat, magnetic force and micro vibrations.n•tThe system should be modern with touch button operation.n•tThe system should consist of two channel unit with 2 hot packs for simultaneous use.n•tIt should have flexible heating pads emitting dry heat so that it can be used over clothes in normal conditions.n•tThe heating pads should have four steps temperature control from 35º to 60ºC.n•tMaximum temperature should not exceed 65 deg for patient protectionn•tIt should provide vibrations through flexible heating pads which help in the stimulation of blood flow on painful areas.n•tThe system should have three different types of micro vibrations as below :notRipple wave: - 70 vibrations per secondnotRandom wave: - 120 vibrations per secondnotBig wave: - 60 vibrations per secondn•tIt should also provide Magnetic force for improving the blood flow.n•tMicro vibration should be from alternating magnetic fieldn•tIt should have digital timer of 30 minutes duration.n•tIt should be supplied with an imported trolley and should work on 240 V/50 Hz power supply.n•tIt should UL, and ISO 13485 approved for patient safety) 89 Wheel Chair for Children– n(The system should have following parameters:n1.tPediatric Wheelchair, Aluminum Chair frame, fixed armrest, Detachable footrest, Drop-back handle, solid castor, pneumatic rear wheel, Anti-tippers.n2.tLoading weight should be minimum 100 kg) 90 Club foot Passive exerciser & Therapy System – n(•tThe CPM should be for treatment of the idiopathic club foot which should restores or maintains ankle and subtalar mobility in addition to preventing fibrosis and periarticular soft tissue changes.n•tThe CPM should be used in the post-operative phase of treatment.n•tThree dimensional movements should be possible:n•tPlantar flexion to Dorsi-flexionn•tAdduction-Varus to Abduction-Valgusn•tPlantar flexion-Adduction-Varus to Dorsi-flexion-Abduction-Valgusn•tDigital controls should allow easy programming.n•tAt rest or working the machine should maintain a light axial traction which off-loads the pressures which are applied to the ankle mortise to avoid any deformation of the tibio-talar joint line.n•tThe machine should be equipped with a system which reverses the movement when abnormal forces are detected.n•tIt should be European CE approved) 91 Children Medical Cycle-n(•tUpright Ergometer for physical abilities such as workload etc. n•tIt should be able to work continuous work load range from 7-1000 watt.n•tIt should work for minimum five minutes at a peak load of 1000 watt for short period.n•tThe work load should be adjustable @ 1 watt increment.n•tIt should have 7 inch touch screen programmable LCD display to show various parameters such as distance, torque, power, energy and time on its control panel.n•tIt should provide workload in hyperbolic, linear and fixed torque modes.n•tIt must have eddy current electro-magnetic braking system.n•tIt should have USB interface.n•tWorkload accuracy should be = 5%.n•tIt should display distance, torque and time on its control panel.n•tIt should have Rotatable height adjustable handlebar redundant, rotate at 360 degrees for comfortable at every seating height. n•tIts seat should be sleeplessly adjustable.n•tIt should comply with MDD 93/42/EEC, incl. IEC.) 92 Ultrasound- 1 and 3 MHz Frequency – n(Digital Dual Pre Programmable Ultrasound therapy unit with constant digital LCD display adjustable treatment should be supplied having following parameters: n?tNominal Frequency: 1MHz & 3MHzn?tPower Density : 0-3W/cm2 (Approx.)n?tMix Acoustic output: 15W (Approx.)n?tUltrasonic Output : Continuous- 2.5 W/cm, Pulse- 3.5 W/cmn?tPulse Frequency: 8hz, 16hz, 50hz, 10hzn?tPulsed Ratios: 1:1,1:4,1:7,1:10n?tTimer: 0-99 minutesn?tVoltage:220 V,50Hz±10%nAccessories to be supplied:n•t1 pair - Ultrasound Head (1Mhz) & Wiren•t1 pair - Ultrasound Head (3Mhz) & Wire n•t1 pc - Main Cord) 93 Computerized Interactive Dynamometer System:-n(Computerized interactive dynamometer system should have following specifications;n•tThe system should comprise of user-friendly and easy-to-control rehabilitation robot to allow rehabilitation Training with dynamically changing resistance, diagnostics, patient evaluation and interactive games.n•tThe system should be upgradable to make use of reactive electromyography (EMG) for neuro exercise. n•tSingle joints or functional and dynamic joint movement should be trained with isolating extensions. n•tThe robotic system should be suitable to provide Kinesitherapy for orthopedic, neurological and cardiac patients of Adult and Pediatric age groups. n•tShould have dedicated exercise program for patients with severe paresis and muscle atrophy. n•tSystem should offer active exercises on all extension for Patients with innerved muscles but severe atrophy n•tThe device should offer exercises for dexterity training with dynamically changing resistance: concentric with elastic resistance and weight simulation.nn•tShould have inbuilt games and dynamic resistance exercises and to improve movement coordination. n•tShould have the facility to upgrade with games working with reactive electromyography n•tShould have tablet mounted on a retractable arm with height adjustable lifting column and preloaded Software application for quick setup and operationn•tShould be mounted on wheels with brakes for easy transportation and immobilization of the robot n•tEach extension should support a maximal applied weight of at least 30 kg. n•tThe rotation axis height of head should be at least 720-1070 mm and rotation limits should be at least 270 degree clockwise and anticlockwise with accuracy at least ±2 deg and Maximum torque: at least 60 Nm with measurement accuracy at least ±0.2 Nm.n•tShould be supplied with changeable extension parts for training and exercise of different joints including Shoulder, Elbow, Hip, Knee, Functional upper limbn•tShould include following extensions easy to mount in any orientation by plug and rotate method and automatic detection by the software: n•tElbow pronation/supination dynamic extension - n•tSteering wheel dynamic extension - n•tUpper limb universal extensionn•t Lower limb universal extension n•tThe system have facility for bioelectric measurements for diagnostic and reactive electromyography with clip electrode for EMG Measurement n•tSystem should have adjustable Range of motion, rotational torque and speed to suit different patient conditions. n•tThe software should provide summary and detailed extension specific information about all performed exercises after every training. n•tSystem Should allow following exercises and diagnosis :na.tContinuous passive motion nb.tProgressive Continuous Passive Motionnc.tSpring (Elastic) exercises:nd.tIsotonic exercises (weight lifting)ne.tDynamic reversalnf.tPrioperception – Hidden/Visibleng.tReactive electromyography trigger and hold nh.tReactive electromyography trigger and release ni.tEMG Biofeedback nj.tDiagnostic EMG nk.tThe software should have three primary game categoriesni.tOrthopedic – acting like concentric exercisesnii.tReactive EMG – acting like reactive electromyography trigger and holdniii.tIsometric EMG – acting like EMG biofeedbacknl.tAt least two games should be provided: Space shooter and Bubble.ni.tSpace shooter a game where the patients control the movement of a spaceship. nii.tBubble- a logic game where patients control the position of a bubble gun launching different color bubbles to form patterns. nThe system should meet the requirements of ISO60601-1-2 for electromagnetic compatibility, including immunity. Should have Class I protection against electric current, Medical device class: class IIa Applied part types: B, BF. ) 94 Lymphatic drainage system 95 BONE GROWTH STIMULATOR 96 Two Channel Combination Therapy With Dual Frequency Ultrasound-n(The Main unit should have:-n•t2 channels electrotherapy unit with 4 electrodes & 1 channel dual frequency ultrasound (1 or 3MHz).n•tColoured touch-screen large LCD for all parameters setting.n•tSimultaneous monitoring of 2 electrotherapy & one ultrasound channel with independent and combined n•tThe unit should operate on100 - 240 VAC 50 Hz.n•tWeight of equipment should be approximately 3.5 Kg for ease of moving.n•tIt should have body diagram with associated clinical programsn•tIt should also have port for attaching vacuum unit. n•tSafety class according to IEC 60601-1: Class 1, Type BFn•tUnit should be European CE approved.nElectrotherapy specifications:n•tDigital Timer: 1-60 minutesn•tIt should also have provision of I/T curve measurement n•tIt should also have setting range for AQ mode whenever vacuum unit is attached.n•tIt should have approximately 28 preset and 120 free program memories n•tVector Sweep 0°, 15°, 30° or 45°nIt should have following setting range:n-tParameter setting range for 2-Pole Interferential moden•tOutput mode: Constant, Sweepn-tParameter setting range for EMS moden•tOutput mode: Surge Independent, Surge Co-Cont., Surge Alternaten-tParameter setting range for Russian moden•tOutput mode: Surge Independent, Surge Co-Cont., Surge Alternaten•tCarrier frequency: 2.5 kHz n•tDuty: 10 to 100% (10% steps)n-tParameter setting range for Hi-Voltage moden•tOutput mode: Constant, Sweep, Burst, Surge Independent, Surge Co-Cont.,n•tSurge Alternaten•tPolarity: positive, negative, alternaten-tParameter setting range for TENS moden•tOutput mode: Constant, Sweep, Burst, Surge Independent, Surge Co-Cont., Surge Alternaten•tWaveform setting: Symmetrical waveform, asymmetrical waveformn•tPolarity: positive, negative, alternaten-tParameter setting range for Micro current moden•tPolarity: positive, negative, alternaten-tParameter setting range for Galvanic moden•tOutput mode: Continuous, Interruptedn•tPolarity: positive, negativen-tParameter setting range for Faradic moden•tPolarity: Positive, negativen•tFrequency: 20 to 250 Hz (10-Hz steps)n-tParameter setting range for Diadynamic moden•tOutput mode: DF, MF, CP, CP-ISO, LP, RSn•tPolarity: positive, negativen•tFrequency: 50 Hz or 100 HznUltrasound specifications:n•tBeam Non-uniformity Ratio (BNR) which prevents hot spots & tissue damage should be less than 5.0 and must be mentioned on the technical literature.n•tEffective Radiating Area (ERA) for large probe should be max. 5 cm2 & for small probe should be max. 1.0 cm2n•tFrequency: 1 & 3 MHz from same headn•tMode: Continuous & pulsed; duty cycle 5-50%n•tMax. Intensity: 3w/cm2in pulsed mode & 2 w/cm2 in continuous mode.n•tDigital Timer: 1-30 minutesn•tMemory capacity of: 18 preset & 10 free Programsn•tUS Probe should be IPX7 protected.nCombination Therapy:n•tIt should work in combination of Ultra sound and electrotherapy with dedicated single electrode of channel 2 as return electrode for electrotherapy and active as US probe.nIt should be supplied with following accessories:nUltrasound head large and small with probe holder, Electrode Cable – 2 pcs., Rubber Electrode, 60x50mm, 2pcs/pack – 2 Pack , Electrode Sponge A, 80x65mm, 2pcs/pack – 2 Pack, Strap (L), 80x1200mm – 2 pcs., Strap (S), 80x600mm – 2 pcs, Ultrasound gel (250 ml), Power Supply Cord (220-240V, Type F) – 1 pc., MCR (Micro current) Probe (2pcs/set to be used), HV/DC ProbenVacuum Unitn•tVacuum unit for enhancing the operability of electrotherapy units especially in abdominal & back regions. n•tThe unit should consist of 2 channel vacuum system for 4 vacuum electrodes.n•tIt should have blow out vacuum system which eliminates the need of water reservoir & reducing maintenance.n•tThe unit should have 2 vacuum modes: Continuous mode & int ermittent mode for patient comfort & skin massage.n•tThe unit should have vacuum strength up to 100 mm Hgn•tThe unit should operate on 100 - 240 VAC with 50 Hz frequency power supplyn•tMain unit should be supplied with:- 4 rubber electrode, 4 electrode sponge, 2 electrode cable, 4 straps (2 large and 2 small), 4 Vacuum electrode, 4 Electrode sponges for Vacuum electrode, Power supply cord.) 97 AUDIOLOGY & SPEECH THERAPY UNIT 98 Single Portable Unit -Pure tone Audiometer with facilities of free field audiometry & speech audiometry with-nFrequency range for AC- 125Hz to 8000HznFrequency range for BC- 250Hz to 6000HznDynamic range (1000Hz)- -10dB HL to 120 dB HLnShould be European CE/ANSI/ISI approved 99 Non-sedated diagnostic BERA with 2 channel and VEMP, ABR & SSR facilities and computer accessibility through USB portal 100 Video Oto-scope with computer accessibility 101 Acoustic booth 15’x12’x 7’ with inner partition, double door, magnetic seal, silenced ventilation 102 Visi-pitch with all accessories 103 Bio feedback system for stammering therapy with all accessories 104 Speech therapy materials (Local purchase) 105 Mattress 6’ x 6’ 106 Group Hearing aid with loop induction system 107 Mattress 6’ x 6’ 108 PSYCHOLOGY UNIT 109 Binet Kamat Intelligence Test (BKT) 110 Intelligence Scale for Indian Children 111 Bhatia Battery of Performance Intelligence Test 112 Diagnostic Test of Learning Disability (DTLD) 113 Diagnostic Test of Reading Disorder (DTRD) 114 Behavioural Checklist for Screening the Learning Disabled (BCSLD) 115 Swarup-Mehta Test of Thinking Strategies (TTS) 116 Thematic Apperception Test (TAT) 117 Non-Verbal Group Intelligence Test (NVGIT) 118 Rorschach Ink Blot Test 119 (DAP:IQ)Draw-A-person Intellectual Ability Test for Children Adolescents and Adults 120 Conduct Disorder Scale (CDS) 121 Revised Hamilton Rating Scale for Depression (RHRSD) 122 Indian Adaptation of the Multidimensional 123 Aptitude Battery - MAB – II 124 Child Sexual Behaviour Inventory (CSBI) 125 Teachers Job Satisfaction Scale 126 ADHD Symptoms Rating Scale (ADHD-SRS) 127 CHILD & ADOLESCENT SYMPTOM INVENTORY-4R (CASI-4R) 128 Multiscore Depression Inventory for Children (MDI-C) 129 Stop Watch [Timer] Racer Electronics [SWE] 130 Gifted and Talented Evaluation Scales 131 Test of Memory and Learning - Second Ed. (TOMAL-2) 132 Early Childhood Inventory-4 (ECI-4) 133 Slosson Full-Range Intelligence Test (S-FRIT) 134 Bender Visual-Motor Gestalt Test - Second Edition (BGT - II) 135 Stroop Color and Word Test (Children) 136 Personality Inventory For Children 2nd Ed. 137 Seguin Form Board Test with Manual & Answer Sheets. 138 Childhood Autism Rating Scale - Second Edition (CARS 2) 139 Children’s Color Trails Test (CCTT) 140 Intelligence Test for Adult 141 State-Trait Anger Expression Inventory-2™(STAXI-2) 142 Multi-dimensional Anxiety Questionnaire (MAQ) 143 Substance Abuse Subtle Screening Inventory (SASSI-3) 144 Suicidal Ideation Questionnaire (SIQ) 145 Relaxation Chair 146 ISAA & INCLEAN TOOLS for ASD 147 BLOOD DISORDER DISABILITY UNIT 148 Thalassemia Rapid test 149 Blood Gas Analyzer 150 Methylene Blue Chemical – 151 Urine Analyzer– 152 VISUAL UNIT 153 Hand held slit lamp 154 Direct Ophthalmoscope 2.8 v 155 Trial set power cotted/Stereo Acuity Test material 156 Trial frame for both adult and paediatric 157 Distance vision testing drum remote control motorised movement 158 VS-V Universal Vision Screener (for school going children also) 159 Tele Binocular Equipment 160 LED Vision Chart 161 Snellen Chart/Eye Testing Drum 162 Automatic Matrix Auto Refractometer R-20 for eye Examination 163 Near Vision Drum 164 Acuity Digital Vision Tester 165 Keratometer&Keratoscope tools 166 Brallier (Braille Type Writer) 167 Orbit Reader (Braille Embossed Reader) 168 Pen Scanner 169 Magnifiers for low vision (NIEPVD) 170 MAGIC software for low vision 171 Electronic Mobility Cane/White Cane 172 TEACHING LEARNING MATERIAL-n(N.B.-All TLM should be made of Nontoxic, Hygienic material ensuring safety of children. Toys should not have any sharp edges to prevent any possible injury to children.) 173 Rattle toys-(Age Group 0 to 3 Years) 174 Fruit Tray-(Age Group 0 to 3 Years) 175 Parts of body-(Age Group 0 to 3 Years) 176 Building Towers-(Age Group 0 to 3 Years) 177 Different Balls-(Age Group 0 to 3 Years) 178 Zig saw Puzzle-(Age Group 0 to 3 Years) 179 Dolls-(Age Group 0 to 3 Years) 180 Wooden Blocks-(Age Group 0 to 3 Years) 181 Drum-(Age Group 0 to 3 Years) 182 English Alphabets & Numbers- (Age Group 3 To 6 Yrs.) 183 Flash Card of Alphabets & Numbers- (Age Group 3 To 6 Yrs.) 184 Eye hand coordination (Beads)- (Age Group 3 To 6 Yrs.) 185 Abacus– (Age Group 3 To 6 Yrs.) 186 Shape, Size, Colour, Concept &. puzzle box – (Age Group 3 To 6 Yrs.) 187 Zig saw Puzzle– (Age Group 3 To 6 Yrs.) 188 Colour book with crayon holder– (Age Group 3 To 6 Yrs.) 189 Easel and Board– (Age Group 3 To 6 Yrs.) 190 Magic Slate– (Age Group 3 To 6 Yrs.) 191 Blowing toys– (Age Group 3 To 6 Yrs.) 192 Picture and Ward Cards - (Age Group 7 To 11 Yrs.) 193 Assembly Kit- (Age Group 7 To 11 Yrs.) 194 Number Cards- (Age Group 7 To 11 Yrs.) 195 Zig Shaw Puzzle - (Age Group 7 To 11 Yrs.) 196 Telling Time Kit - (Age Group 7 To 11 Yrs.) 197 Count and Match - (Age Group 7 To 11 Yrs.) 198 Puzzle body parts - (Age Group 7 To 11 Yrs.) 199 Coloring Books with Crayons– (Age Group 7 To 11 Yrs.) 200 Beads– (Age Group 7 To 11 Yrs.) 201 Magic Slate– (Age Group 7 To 11 Yrs.) 202 Duplicate Currency– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 203 General Knowledge Flash Cards– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 204 Mobile Phone– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 205 Calculator– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 206 Digital Watch– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 207 Number Cubes– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 208 Multiplication Tactile Board– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 209 Worksheet, Pen & Duster, Story Books– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 210 Coloring Books with Crayons– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 211 Kitchen Set– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 212 SPORTS MATERIALS 213 Recreational Gaming Play Station 214 Eye Convalescence System –with Bed 215 EMG Biofeedback With Pelvic Floor Rehabilitation For Urinary Incontinence
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
15.
Housing Urban and Rular Development #10593934 Price Bid
tender for Charges for Design, Development, Implementation, Operational Training & Support for 1 year for Additional New features in the already developed Software Modules and New Software Modules in “Nivesh Sarathi Portal” and Design, Development, Implementation, Operational Training & Support for 1 year for Land Bank Management Module for Invest UP. Sl. No. Item Description 1 Investment Facilitation Tracking Mechanism 2 User Management 3 Golden Card Issuance Mechanism 4 Customization with Upgradation of the existing Android & iOS Based Mobile App to incorporate the additional functionalities and modules 5 Development of New Software Modules in Nivesh Sarathi Portal: 6 Target for Ground Breaking Ceremony (GBC) and Global Investors Summit (GIS) 7 Intent-wise Query Redressal Mechanism 8 Integration of Nivesh Sarathi Portal with UP GIS Portal 9 MoUs for UP GBC & GBC 4 Project Status 10 Physical and Ground Verification of GBC Ready Projects 11 Key Performance Indicators (KPIs) Monitoring module for One Trillion Dollar Economy (OTDE) project 12 Module for on-ground verification of investments made under the GBC 1, 2 & 3 of GIS 2018 13 Integration with CM Dashboard (Darpan) 14 Third Party Services : 15 Security Audit of the above module from Cert-In Empanelled Agency (On Half Yearly Basis) 16 Annual maintenance charges of Additional New features for already developed Software Modules and New Software Modules in “Nivesh Sarathi Portal” : 17 AMC of Additional New Features for already developed Software Modules 18 Lead Management System / Query Redressal Mechanism 19 File Investment Intent/MoU Signing Mechanism 20 Investment Facilitation Tracking Mechanism 21 User Management 22 Golden Card Issuance Mechanism 23 Customization with Upgradation of the existing Android & iOS Based Mobile App to incorporate the additional functionalities and modules 24 AMC of New Software Modules in Nivesh Sarathi Portal 25 Target for Ground Breaking Ceremony (GBC) and Global Investors Summit (GIS) 26 Intent-wise Query Redressal Mechanism 27 MoUs for UP GBC & GBC 4 Project Status 28 Physical and Ground Verification of GBC Ready Projects 29 Key Performance Indicators (KPIs) Monitoring module for One Trillion Dollar Economy (OTDE) project 30 Module for on-ground verification of investments made under the GBC 1, 2 & 3 of GIS 2018 31 Integration with CM Dashboard (Darpan) 32 Third Party Services : 33 Security Audit of the above module from Cert-In Empanelled Agency (On Half Yearly Basis) 34 Design, Development of Land Bank Management System 35 Design, Development of Land Bank Management Module with following features:• Secure login for District Magistrate and Admin via Nivesh Sarathi Portal, with password recovery and notifications.• Provision for Admin to create, edit, and delete unique sector masters, visible to IDA and DM logins.• IDA users can push land details via an API, including plot identification, pollution index, plot size, rate, and allotment status.• DM users can input land details through a form, covering sub-division, location, village, land type, and plot specifics.• Admin access to all land details added by IDA & DM for review and utilization.• Personalized dashboards for users, with customization options and a public dashboard for investors/stakeholders.• Customizable report generation with filters for authority, district, pollution index, plot status, size, and rate.• Downloadable reports in CSV, Excel, and PDF formats.• Seamless integration with Nivesh Sarathi Portal for enhanced user experience and investment processing.• SMS and email alerts at necessary steps during login, password recovery, and data entry processes. 36 Third Party Services : 37 Security Audit of the above module from Cert-In Empanelled Agency (On Half Yearly Basis) 38 Following Additional Resource to be added in the existing Application Server for Land Bank Module :• Additional 4 cores • 12 GB RAM• Additional Disk Space of 1.5 TB• Additional Backup Space of 1.5 TB on Different DCFollowing Additional Resource to be added in the existing Database Server :• Additional 4 cores • 16 GB RAM 39 AMC of Land Bank Management System : 40 AMC of Land Bank Management Module with following features:• Secure login for District Magistrate and Admin via Nivesh Sarathi Portal, with password recovery and notifications.• Provision for Admin to create, edit, and delete unique sector masters, visible to IDA and DM logins.• IDA users can push land details via an API, including plot identification, pollution index, plot size, rate, and allotment status.• DM users can input land details through a form, covering sub-division, location, village, land type, and plot specifics.• Admin access to all land details added by IDA & DM for review and utilization.• Personalized dashboards for users, with customization options & a public dashboard for investors/stakeholders.• Customizable report generation with filters for authority, district, pollution index, plot status, size, and rate.• Downloadable reports in CSV, Excel, and PDF formats.• Seamless integration with Nivesh Sarathi Portal for enhanced user experience and investment processing.• SMS and email alerts at necessary steps during login, password recovery, and data entry processes. 41 Third Party Services : 42 Security Audit of the above module from Cert-In Empanelled Agency (On Half Yearly Basis) 43 Following Additional Resource to be added in the existing Application Server for Land Bank Module :• Additional 4 cores • 12 GB RAM• Additional Disk Space of 1.5 TB• Additional Backup Space of 1.5 TB on Different DCFollowing Additional Resource to be added in the existing Database Server :• Additional 4 cores • 16 GB RAM 44 Total 45 UPDESCO margin@10% 46 Total Cost including UPDESCO margin 47 GST@18% 48 Overall cost including taxes Table (A+B+C+D+E+F+G+H)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttar Pradesh View Result →
16.
Water Resources and Irrigation #10558790 Price Bid
Supplying, Installation, Testing & Commissioning of Mix-flow type Electric Pump Sets & equipments with all accessories etc. including development of Substation for New Pump House at Jahangirpuri drain near Gopalpur Regulator RD-1135m.- 1 Supplying, installation, testing and commissioning of totally enclosed fan cooled squirrel cage 3-Phase induction motor confirming to protection IP 55 Horizontal foot mounted suitable for open duct on 415+/- 10%, 3-Phase 50HZ +/- 5% AC supply with Ambient 50°C class F insulation 55 KW/75 HP , 6 Pole , 980 RPM with performance standard confirming to IS 12615 coupled with suitable size standard Coupling to MF 35x35 Size Pump set having 1400 m3/hr discharge at 10 mtr head and CI casing, SS Impeller, SS shaft, SS shaft sleeve with Gland packed shaft sealing complete with all standard accessories mounted on frame of suitable size with complete grouting or mounted on suitable cushyfoot vibration mounting pad completed etc. as required at site(Motor Make:- Kirloskar/Crompton/ A.B.B./ Siemens) (Pump Make:- Kirloskar/ Wilo/ Flowmore/KSB) 2 Supplying, installation, testing and commissioning of totally enclosed fan cooled squirrel cage 3-Phase induction motor confirming to protection IP 55 Horizontal foot mounted suitable for open duct on 415+/- 10%, 3-Phase 50HZ +/- 5% AC supply with Ambient 50°C class F insulation 75 KW/100 HP , 8 Pole , 740 RPM with performance standard confirming to IS 12615 coupled with suitable size standard Coupling to MF 40x45 Size Pump set having 2000 m3/hr discharge at 10 mtr head and CI casing, SS Impeller, SS shaft, SS shaft sleeve with Gland packed shaft sealing complete with all standard accessories mounted on frame of suitable size with complete grouting or mounted on suitable cushyfoot vibration mounting pad completed etc. as required at site(Motor Make:- Kirloskar/Crompton/ A.B.B./ Siemens) (Pump Make:- Kirloskar/ Wilo/ Flowmore/KSB) 3 Supplying , installation, testing and commissioning of Sound Proof Steel enclosure Water Cooled Engine coupled with Alternator 320KVA/256 KW silent DG Generator set including Base frame, Radiator/Heat Exchanger/Fuel Tank/ Control Panel /AMF panel, fuel piping foundation, all interconnections, loop Earthing, Silencer completed all as per CPWD/CPCB norms with standard accessories etc. as required.(Make:- Crompton Greaves/ Kirloskar/ Cummins or as approved by Engineer-in-charge) 4 M.S. Pipes:-Manufacturing , Supplying, erection & commissioning of Mild Steel ERW, (Electric Resistance welded) Pipe fabricated/manufactured out of Fe410 Mild Steel Grade 330 as per IS: 3589 of reputed & approved make , including painting with epoxy paint inside and outside surface with two coats of anticorrosive paint of approved brand and manufacture : all conforming to relevant IS codes: complete in all respect and with upto date amendments in relevant IS codes:(Pipe make:- Jindal/ Surya/ Tata or as approved by Engineer-in-charge)1200mm nominal dia pipes of 12mm thick complete as required at site. 5 350mm nominal dia pipes of 8mm thick complete as required at site. 6 400mm nominal dia pipes of 8mm thick complete as required at site. 7 450mm nominal dia pipes of 8mm thick complete as required at site. 8 MS Flanges:- Manufacturing, Supplying, fixing & welding of following sizes M.S. Flanges etc complete. as requiredat site. 1200mm dia. & 25mm thickness. 9 350mm dia. & 20mm thickness. 10 400mm dia. & 20mm thickness. 11 450mm dia. & 20mm thickness. 12 MS Bends:-Manufacturing, Supplying, fixing & welding of following sizes M.S. Bends etc. complete. as requiredat site. 1200mm dia. 13 350mm dia. 14 400mm dia. 15 450mm dia. 16 MS Dummy Flanges:-Manufacturing, Supplying & fixing of M.S. Dummy Flanges etc. of following sizes complete as required at site. 1200mm dia. & 25mm thickness. 17 350mm dia. & 16mm thickness. 18 400mm dia. & 25mm thickness. 19 C.I. Sluice Valves:-Providing & Fixing of following sizes Cast Iron Sluice gate Valve suitable for Pressure 1.0 PN complete in all respects as required at site. (Make: - Kirloskar/Kartar/Sant or as approved by Engineer-in-charge)350 mm nominal dia. 20 450 mm nominal dia. 21 C.I. Non Return Valves :-Providing & Fixing of following sizes Cast Iron Non Return Valve suitable for Pressure 1.0 PN complete in all respects as required at site. (Make: - Kirloskar/Kartar/Sant or as approved by Engineer-in-charge)350 mm nominal dia. 22 400 mm nominal dia. 23 Nut/Bolts/Washers:-Manufacturing & Supplying of Nuts,Bolts & Washers etc. of size 7/8 x 6 as required at site. 24 Rubber Gaskets:-Manufacturing, Supplying & Fixingof Rubber Gaskets of thickness 6mm or more for following sizes M.S. Pipelines Flanges as required at site.1200mm nominal dia. 25 350mm nominal dia. 26 400mm nominal dia. 27 450mm nominal dia. 28 Vaccum Pump:-Supplying, Installation, Testing and Commissioning of DV-50 Vaccum Pump sets having C.I. casing and C-40 shaft with 10 H.P. energy efficiency LV motor, 3 phase, 415volt 50hz, 1500RPM +/- 5%, TEFC induction motor mounted on suitable size M.S.base frame coupled on existing foundation withall accessories like ML 1.5 starter, anti vibration mounting pad, coupling, nut-bolts & packing etc. complete in all respect i/c providing, fitting & testing ofheavy class M.S. pipe of 50mm dia.of requiredlength with necessary Gate valve and mountings etc.for chargingof pump sets. ( Pump:- Kirloskar make or as approved by Engineer-in-charge) (Motor:- Kirloskar/Crompton /ABB or as approved by Engineer-in-charge) (Pipe make:- Jindal/ Surya/ Tata or as approved by Engineer-in-charge) 29 Supplying, installation, testing & commissioning of Energy efficient 630 KVA, 11/0.433 KV, 3 phase, 50Hz, Dyn11, outdoor ONAN type, copper wound Transformer with off load tap changing arrangement on HV side , Tapping range +5% to -10% in steps of 2.5%having Cable boxes on HV/LV side suitable for 3 x 240 Sq.mm. XLPE Cable of 11 KV grade with accessories, buckholz relay i/c first filling of filtered dehydrated oil and confirming to IS 335& Transformer losses as per IS 1180 level-2 & as per specification attached complete in all respects as required at site. • Max Continuous Rating = 630 KVA • Voltage Ratio = 11/0.433 KV• Tapping (Range/ Step) off Circuit Tap Changer = +5% to -10% in step of 2.5% off load • Insulation Class = A Class • Application of the Transformer = Distribution• Vector Group = Dyn 11• Temperature Rise at Rated Load over Ambient of 40°/50° C• Cooling = ONAN(Make:- Kirloskar/Schenider/ABB or as approved by Engineer-in-charge) 30 Supplying, Installation, Testing and Commissioning of Indoor Type Floor Mounted metal clad, 11KV VCB Panel with 1 No. VCB for ICOG System (Incoming-Outgoing System), Totally Enclosed. Horizontal drawout, Horizontal/Vertical Isolation type Breaker as per IS 13118 & as ammended upto date and additional specifications as mentioned below, manually charged and motorized /manually closing breaker suitable for use on 11 KV, 3 Phase, 50 Hz A.C. supply with short circuit fault level of 350 MVA, complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated but encapsulated Aluminium Bus Bars of 800 Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 4 NO+4NC and equipped with following switchgears and accessories i/c connections suitable for 3 x 95 sqmm XLPE 11 KV cable (cable entry frombottom/top/side) (MAKE:- Kirloskar/ L&T/ Crompton/Schenider)1. All CTs and PTs shall be cast resin type.2. 2. All PTs should be Fixed type.Detailed Specifications:-1 Nos. 800A TP Electrically drawout type Vacuum Circuit Breaker, 11KV, 20KA/3 seconds suitable for 630A TP, EDO, 18.4KA/1 second with following accessories:a)Spring Charge Motor, 240V A.C, Closing Coil 24V DC, Shunt Trip Coil 24V DC, Operation Counter with Mechanical ON/OFF Push Buttonb)Mechanical Indicator ON/OFF, Aux. Contacts 4NO + 4NC, Spring Charge/Discharge,Mechanical Spring Charging Device.c)Mechanical Emeregency Push Button2. 1 No. 11 KV / 110V PT class 0.5 accuracy and 100 VA burden with 1 No. voltmeter (0-15 kV), digital type, selector switch for voltmeter and protection fuses / MCB for HT metering up to 12 KV on incomer.3. 1 No. Microprocessor based numerical relay with O/L,E/F and S/C protection.4. 1 sets of 3 nos dual core dual ratio CTs 50/50/5/5A of 15 VA burden and accuracy class - 0.5 for metering and class 5P 10 for protection.5. Flush mounted Type High Speed Tripping Relay,6. Flush mounted Type DC Operated Auxiliary relay for Transformer Faults with Three Pair of Relay Element7. 1 Nos. Anti Pumping relay8. Annunciator Set 8 Window Type with Hooter for Fault Indication9. Supplying, Installation, Testing and Commissioning of Power pack with 220 volt AC input & 24 volt DC continuous output suitable for closing / tripping / indication of 1 No. HT Panel Boards with 2 Nos. 12 volts each maintenance free batteries of 100 AH each, charging unit, capacitor bank for emergency delivering for Trip system complete with suitable capacity of Ammeter & voltmeter i/c connections with 2.5 sqmm FRLS insulated copper conductor cable etc. as required. 31 Fabrication Supply Installation Testing and Commissioning of Main L.T Panel suitable for 415 Volt, 3 Phase 4 Wire System, 50Hz AC Supply. Panel Shall be fabricated out of 1.6MM thick CRCA Sheet for load bearing and non load bearing members, Gland Plate shall be fabricated out of 2MM thick CRCA Sheet. Panel shall be Powder coated with RAL 7032 Shade for Doors and Body and have suitable solid links for Incoming ond Outgoing of the ACB with Electrical Grade Aluminium of 1000 Ampere Capacity supported on DMC/SMC Bus Bar Supports. Earthing shall be done with 25 X 5MM G.I Strip running acroos the Panel Length. The Control Wiring for Metering and Display Instruments shall be done with PVC Insulated 1.1KV Grade multi stranded copper wire of 2.5 Sqmm. Proper Ventilation system for heat disipation shall be provided with Panel including ventialtion fan and louvers. The Panel Shall not be less than 1875 X 2000 X 750 m.m or Cm³(H,L&D) The Panel shall be fitted with the following switchgear & instruments as mentioned below:-Incoming:-a)1000A TP ACB, Manually Type with following protection features such as Overload and Shor Circuit protectionb)Digital Type Multifuntion Meter, bearing Cl 1 Accuracy without RS485 Portc)Phase Indication Lamps for R-Phase, Y-Phase and B-Phase, 240V A.Cd)ACB ON and OFF Indication Lampse)6A SP MCB, 10KA Breaking Capacity for Protection and Control Circuitf)1 Set of 1000/5 CT, CL-1.0, 15VA Burden Tape WoundOutgoing:-a)55KW Star Delta Starter with ML4 contractors and 200A TP MCCB 36KA Breaking Capacity with suitable Handle and Spreaders: 4 Nosb)30KW Star Delta Starter with ML3 contractors and 200A TP MCCB 36KA Breaking Capacity with suitable Handle and Spreaders: 4 Nosc)400A TP MCCB, 36KA Breaking Capacity having Thermal Magnetic Release with O/L and S/C Protection : 4 Nosd)200A TP MCCB, 25KA Breaking Capacity having Thermal Magnetic Release with O/L and S/C Protection : 1 Nos.e)125A TP MCCB, 25KA Breaking Capacity having Thermal Magnetic Release with O/L and S/C Protection : 1 Nos.f) 100A TP MCCB, 25KA Breaking Capacity having Thermal Magnetic Release with O/L and S/C Protection : 4 Nos. 32 Supplying, installation, testing & commissioning of Cubical Type Phase sequence corrector suitable for 415 Volt, 3 Phase 4 wire, 50 Hz AC supply system fabricated in compartmentalized design from 2mm thick CRCA sheet of size for frame work and covers, having Gland plate less than 3mm including cleaning and finishing complete with powder coating in approved shade, having links not less 600A capacity. the Bus Bar support (wherever required) with short curcuit withstand capacity of 31 MVA for 1 sec.Entire panel shall have a common Earth Bus of suitable size at the Rear with 2 Nos. Earth stud, solid connections from main Bus Bar to switch Gears with requires size of Aluminium Bus Bar (wherever required) and control wiring shall be done with 2.5 sq.mm PVC insulated copper conductor single core cables. Including providing and fixing the following switch Gear.A) Materiala) 580A Three Pole Power Contactors, AC3 Duty, Coil voltage 220 V A.C: 2 Nos. (Make:- ABB/L&T/C&S)b) LED type indication Lamps RYB (3 set) Aux. Supply: 220V A.Cc) Control Miniture Circuit Breaker (3 Nos.) SP, 10KA : 6Ad) Single Phase Digital Type Ampere Metre, 3 Phase 4 wire system, Flush type 96 Sq.mm. (1 Nos.) Class-1 accuracy, CT-Input-5A, Aux. Volt-220V,ACe) Ampere Selector Switch (1No.) Rating : 6Af) Single Phase Digital Type Volt Metre, 3 Phase 4 wire system, Flush type 96 Sq.mm. (1 Nos.) Class-1 Accuracy, Range:- 0-500 V, Aux. Volt:220V, A.Cg) Voltage Selector Switch (1No.) Rating : 6Ah) Current transformer 600/5A, Single Ratio, Single Core, 1Ø (3 Nos.) , Tape wound, CL-1.0 & 15VAi) LED type Indication LampsON/OFF (2 set) Aux. Supply: 220V A.Cj) Auto/ Manual selector switch (2 Nos.), Rating : 6Ak) Phase Sequence correction relay (1 Nos.) Aux Volt :220V, A.Cl) Audio Indication for Phase sequence Reversal(1 Nos.) Hooter : 220V A.C.m) On Delay Timer (1 Nos.) Aux Volt :220V, A.C 33 SITC of 200KVAR APFC Panel made out of 1.6mm Thick CRCA Sheet duly powder coated complete with suitable size of Al. Bus Bars & internal wiring with suitable size of Copper wire including Providing and Fixing following Switchgear and Metering instruments complete as required. Panel size shall not be less than 1575m.m or Cm³*1900*350.. the Capacitors Shall be Divided as per the mentioned Pattern for 200KVAR SystemA) MaterialMain Incomer:-a) 400A TP MCCB, Thermal based Release with O/L & S/C Protection: 1 Nos.b) Rotary Operating Mechanism: 1 Nos.c) Phase Spreaders: 1 Setd) 12 Stage APFC Relay, Microprocessor Based, with Different Display Parameters.e) Phase Indication Lamps, 220V-240V AC : 3 Nos.2) Outgoing:-a) 63A TP MCCB, Thermal Magnetic Release with O/L & S/C Protection, with ROH and Spreaders: 6 Nosb) 40A TP MCCB, Thermal Magnetic Release with O/L & S/C Protection, with ROH and Spreaders: 2 Nos.c) 25A TP MCCB, Thermal Magnetic Release with O/L & S/C Protection, with ROH and Spreaders: 2 Nos.3) 200 KVAR Capacitor, MPP and Cylindrical Type:-a) 25KVAR Capacitor Bank: 6 Nos.b) 15KVAR Capacitor Bank: 2 Nos.c) 10KVAR Capacitor Bank: 2 Nos.4) Capacitor Duty Contactors of Various Ratings for Capacitor Switching:-a) Capacitor Duty Contactors for 25KVAR Cap. Bank , MOC 25 or Equivalent : 6 Nosb) Capacitor Duty Contactors for 25KVAR Cap. Bank , MOC 15 or Equivalent : 2 Nosc) Capacitor Duty Contactors for 25KVAR Cap. Bank , MOC 10 or Equivalent : 2 Nosd) Side Mounting Block : 10 Nose) Push Button with Element Set for Manual Start & Stop of Capacitor Bank : 10 Setsf) Indication Lights for Capacitor ON Indication : 20 Nos.g) 4 Ventilation Fans with Louvers for Cross Air Ventilation : 1 Nosh) Auto/Manual Selector Switch for Auto/Manual mode of Operation : 1 Nos. 34 Copper Conductor LT Cables:-Supplying, Laying and fixing of following sizes P.V.C. insulated and P.V.C. sheathed/ XLPE CopperConductorarmoured Cable of 1.1 KV grade as per IS:1554 or amendment up-to-date on surface including connection making, taping etc. complete as required. (Make:- National/Grandlay/ Glouster/ Poly-Cab/ Havells/ Phinolex or as approved by the Engineer-in-charge)4C x 10 sqmm. 35 4C x 120 sqmm 36 4C x 150 sqmm 37 Aluminium Conductor LT Cables:-Supplying, Laying and fixing of following size P.V.C. insulated and P.V.C. sheathed/ XLPE AluminiumConductorarmoured Cable of 1.1 KV grade as per IS:7098 or amendment up-to-date on surface including connection making, taping etc. complete as required. (Make:- National/Grandlay/ Glouster/ Poly-Cab/ Havells/ Phinolex or as approved by the Engineer-in-charge)3.5C x 300 sqmm 38 3.5C x 150 sqmm 39 Aluminium Conductor HT Cables:-Supplying, Laying and fixing of following size P.V.C. insulated and P.V.C. sheathed/ XLPE AluminiumConductorarmoured Cable of 11 KV(E) grade as per IS:7098 or amendment up-to-date on surface including connection making, taping etc. complete as required. 3.5C x 300 sqmm(Make:- National/Grandlay/ Glouster/ Poly-Cab/ Havells/ Phinolex or as approved by the Engineer-in-charge) 40 Supply and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 x 16 sq. mm 41 4 x 35 sq. mm 42 4 x 10 sq. mm 43 Supply and making outdoor end jointing with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 11 KV grade as required.3C x 300 sq. mm 44 Supplying & fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth busbar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 6 way, Double door 45 8way, Double door 46 Supplying and fixing metal box of 100mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 47 Supplying, installation, testing & commissioning of energy efficient LED Flood light luminaries of system wattage 72 watt complete with mounting brackets & accessories i/c connections complete as required.(Make:- Bajaj/Philips/Crompton/Halonix) 48 Supplying and fixing followingpiano type switch/socket on the existing switch box/ cover including connections etc. as required. 5/6 amps switch 49 15/16 amp switch 50 3 pin 5/6 amp socket outlet 51 6 pin15/16 amp socket outlet 52 Supplying and fixing (two module) stepped type electronic fan regulator on the existing modular plate switch box including connection but excluding modular plate etc. as required. 53 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, , miniature circuit breaker suitable for inductive load of folloeing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole 54 Single pole and neutral 55 Wiring for light point/fan point/exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVS insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular plate, sitable GI Box and earthingthe point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Group C) 56 Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.2x2.5 sq.m + 1x2.5 sq.m earth wire 57 2 x 4 sq. mm +1 x 4 sq.mmearth wire 58 Supplying, installation, testing and commissioning ofHeavyduty following sizes exhaust fan 900 RPM totally enclosed heavy duty motor with die castaluminium rotor suitable for operation on 240 volts 50 Hz AC single phase Supply including installation of exhaust fan in the existing opening, making good the damages as required. .(Bajaj, Usha, Khaitan, Havells, Orient ) or as approved by Engineer-in-charge.450 mm Sweep 59 Supplying, installation, testing and commissioning of 1200 mm sweep AC electric ceiling fan capacitortype with double ball bearing complete with down rod, canopies, shackles, blades but without regulator suitable for operation on 230/240 volts, 50 Hz single phase AC supply including wiring the down rod of standard lenth up to 1 mtr with 2x1.5 sq. mm PVC insulated copper conductor with fan sheet etc. as required.(Make:- Bajaj/ Usha/ Khaitan/ Havells/ orientor as approved by Engineer-in-charge) 60 Supplying, installation, testing & commissioning of prewired Indoor decorative 18/20 watt LEDbatten extruded aluminum housing& opal diffuser. IP20 complete with all accessories including connection making etc. as required. (Make:- Bajaj/ Halonix/ Havell’s/ Crompton/ Phillipsor as approved by Engineer-in-charge) 61 Supplying and fixing of following size P.V.C. insulated sheathed /XLPE Aluminum conductor cable of 1.1 KV Grade armoured as per IS:7098 on surface as required. (National,Grandlay, Glouster, Poly-Cab, Phinolex or as approved by Engineer-in-charge). 2 x 10 sq.mm 62 Earthing with G.I earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. 63 Providing and fixing 25 x 5 mm G.I.strip on surface or in recess including connection etc. as required. 64 Providing and laying 6 SWG G.I wire on surface or in recess for loop earthing along with existing surface/recessed/conduit/submain wiring/cable etc. as required. 65 Supplying, Installation, Testing and commissioning of 7.5 Tonne capacity Single Girder E.O.T. Crane comprising of Main Girder, End carriages -02 nos with long travel motors – 02 Nos, 01 Nos 5 Tonne capacity Wire Rope Electric Hoist, pendant controlled along with brakes, limit switches and electric panel. All motors i.e. Hoisting/ Lowering, cross travel and long travel shall be compatible with VVVF drive and the speeds can be adjusted from zero to maximum speed. The complete system includes erection of columns, LT Girders, LT rail/ Sq Bar, 01 no DSL system (Shrouded type)(MAKE: - GLOBE/ WH BRADY/ GARLIC) 66 Supplying, Installation, Testing and commissioning ofNew Generation Energy Saving & Environment friendly long versatile pressure die cast aluminium IP 66 roadway luminaire with high power 150 Watt LED street lights complete with all accessories etc. as required.(Make:- Phillips/Bajaj/Crompton/Halonix/ Havells or as approved by Engineer-in-charge) 67 Supplying, Installation, Testing and commissioning ofNew Generation Energy Saving & Environment friendly long versatile pressure die cast aluminium IP 66 roadway luminaire with high power 100 Watt LED Flood lights complete with all accessories etc. as required.(Make:- Phillips/Bajaj/Crompton/Halonix/ Havells or as approved by Engineer-in-charge). 68 Fabrication & installation of S.S. Bar Screen/ Jaal inside Suction side of Pump Sump in slightly inclined position of required height with M.S. Platform etc. for ease of removal of foreign materials, hyacinth, jute, bags etc. from the suction side completed etc. as required at site.Construction, maintenance and subsequent removal of earthen bundies including cost of excavation earth filling of E.C. bags with earth, stitching and placing in position for care and diversion of all kinds of water entering or flowing in the drain and pumping out surface as well as under groung seepage water to keep the construction area completely dry for execution of entire work including its execution of work in or under water and or liquid mud wherever required with round the clock watch & ward/maintenance of earthen bundies to keep the working area/site dry complete as per specification & direction of Engineer-in-charge. 69 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500 D or more. 70 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. 71 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cementconcrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverableseparately). All works upto plinth level. 72 Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 73 Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as Nuts, Bolts,fasteners etc.).
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
17.
Drinking Water Supply and Sanitation #10523073 Price Bid
Tender For Interception & Diversion (I&D) & Stp For Existing Drain In Dhampur Town/Npp, Distt Bijnor - Civil Works of 7.2 MLD STP and 7 KLD Septage Co-Treatment Facilities 2 Design, Construction, Supply of all materials, Erection and Commissioning of 7.2 MLD STP and 7 KLD Septage Co-Treatment Facilities with all the civil,LT/HT panel room, sub station building, DG set foundation, admin buidling, laboratories, meter room and campus development [Construction of Internal Road (CC Road, 3.6m wide, area approx 2000sqm),fiiling of earth if required]fully furnished administrative building having fully functional testing laboratory, PLC/SCADA Rooms, Power Generation building, Blower building, sludge handling system & other building required for technology proposed. OCEMS system at inlet & outlet of STP and master control station (MCS) at STP. Conference room suitable for 15 people, 4 rooms with a attached toilet for supervisory staff and a toilet block, drinking water cooler, all office rooms and conference room (Air Conditioned)., staff quarters as per requirement and specification, external water supply (20KL tank including tube well and pumping arrangement,sanitation work) etc. all complete for STP with co-treatment facilities. STP shall be based on SBR Technology OR any proven technology. The effluent quality for agricultural uses (PH-6.5 TO 8.3, SS-30 mg/l, Oil&Grease-10 mg/l, BOD-10mg/l) , COD-30 mg/l , Residual chlorine-nil , TKN-10mg/l, Nitrate N-10 mg/l, F.C.-230 MPN/100 ml, Dissolved P-5 mg/l (preferable 2 mg/l). ) shall be maintained asper CPHEEO manuals. Latest NGT norms for effluent discharge shall be adhered. The cost is inclusive of (Peak flow 24.11 MLD) (civil works). 3 INTERCEPTOR SEWERExcavation below G.L. upto depth as specified for laying sewer and manhole ordinary soil (earth, sand, loam and clay) including cutting of joints pits ramming dressing) leveling, refilling of trenches in 20 cm layer watering and ramming the same including (8% reduction due to excavation already taken in manhole and SCC) 4 (a)0.00 to 1.50 m 5 (b) 01.50 to 03.00 m 6 (c) 03.00 to 04.50 m 7 Provide and fix close timbering in trenches for the depth as specified below G.L. consisting of 40 mm thick approved country wood plank for polling board 125 x 75 mm eucalyptus-Safeda-Sal Wood wallers and 100 mm dia ballies for shuttering at 1.5 m C/C including all labour etc , complete 8 (a)1.5 to 3 m 9 (b) 03.00 to 06.00 m 10 Same as item No. 3 but for open timbering (No timbering for depth <1.50m) 11 (a) 1.50 to 03.00 m 12 Timbering left in trenches (No timbering for depth <1.50m) 13 Open Timbering left in trenches (used timbering) 0-3m depth 14 Closed Timbering left in trenches(used timbering)0-3m depth 15 Closed Timbering left in trenches(used timbering)3-6m depth 16 Supply of following sizes of RCC spigotted and socketed non pressure pipes( Dia. In mm ) with structural strength as per IS 458 : 2003 and its latest amendment(s).NP3 17 600 mm dia 18 700 mm dia 19 Carting following sizes of R.C.C. Hume pipe NP3 Class Socket / spigot rubber ring jointing and specials from store to the work lowering and laying the same in to the trenches upto depth as specified below G.L. true to alignment600 mm dia pipe 20 01.50 - 0 3.00 m 21 03.00 - 04.50 m 22 700 mm dia pipe 23 01.50 - 0 3.00 m 24 Cement concrete work in bedding below G.L. at specified depth with cement, coarse sand and 20 mm gauge approved stone ballast (1:2:4) including supply of all materials, labour, T&P etc. required for the proper completion of work. 25 (c) 03.00 to 04.50 m 26 Filling granular material (well graded crushed rock or gravel maximum size 20mm) into the trenches for class B bedding (granular bedding) including watering compaction, labour T&P etc. for completion of work. 27 (b) 01.50 to 03.00 m 28 Supply (excluding cartage) of granular material (well graded crushed rock or gravel of maximum size 20mm)for class B bedding (granular bedding) 29 Construction of circular type brick masonry HD (HD25) manhole (with Extra Heavy Duty type manhole cover) with top slab made of cement concrete 1:1.5:3 with graded granite stone aggregate (12 mm nominal size), wall made of brick masonry using 1st class bricks having crushing strength between 100 to 149 kg/cm² in cement mortar 1:4 inside plastering 12 mm thick 1:4 finished smooth with neat cement, pinning, outside plaster 1:4 and making channels with cement concrete 1:2:4 graded granite stone aggregate (12 mm nominal size) complete with including Plastic Encapsulated M.S. foot Rest staggered at 0.375 mtr interval, including excavation, reinforcement. 30 1200mm internal dia., 3.30m deep 31 1500mm internal dia., 4.95m deep 32 Extra for every additional depth of 1 m or part there of in following size of circular manholes. 33 1200mm internal dia., 3.30m deep 34 1500mm internal dia., 4.95m deep 35 Dismantling/Cutting of Cement Concrete road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materialsas per direction of Engineer Incharge. 36 Reinstatement of Concrete road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materials as per direction of Engineer Incharge. 37 Providing and erecting temporary barricading at site as per drawing/ direction of Engineer-in-Charge which includes hiring of Ballies and arrangement for traffic diversion such as traffic signals during construction at site as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work). The rate is for unit length of pipe laying. 38 Disposal of Surplus Earth as per direction of Engineer Incharge. 39 Construction of Boundary Wall 2.0m ht. above plinth level 0.23m width with RCC Column @3m c/c with plinth beam and foundation avg. 2 m depth including reinforcement and RCC coping on top of wall with plaster (1:4) and painting (apex painting 3 coat) as per type design and drawing at the STP site 40 MS gate (3.6m wide with 1.50m wicket gate with 0.35 m x0.35m RCC piller) 41 Cnstruction of Intermediate Pumping Station (IPS) as per specification, accesory building & design approved by Engineer in Charge 42 Sewage Rising main from IPS Excavating trenches for pipes including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc., and disposing of surplus excavated soil as per direction of Engineer Incharge. 43 0.0 to 1.5 mtr. Depth (do - in all kindes of soil) 44 Supply of 400mm dia. DI K9 pipe and special for the pumping mains including all complete pipes conforming to IS : 8329- 400 mm 45 Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc.(400mm) 46 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete 150 mm 47 Carting of 400mm dia DI K9 pipe and specials from store to the work lowering the same in to the trenches upto depth as specified below G.L. inclduing testing of pipes etc. 48 Providing & Constructing masonry Chamber 1.5x1.5x1.5 m inside, in brick work in cement mortar 1:3 (1 cement : 3 coarse sand) for valve, withcast insitu RCCslab with necessary reinforcment.The valve chamber shall be plastered with CM 1:4, A levelling coars of M10shall be provided.The cost is inclusive of excavation , disposal and construction of valve chamber with moduar bricks plasting with cement mortar with all lead and lift etc., as per specification & drawing 49 Sluice valve, Air valve chambers 50 Dismantling/cutting of the BOE road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m. 51 Reinstatement of the BOE road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m. 52 Interception and diversion (I&D) Structure works 53 Cnstruction of Interception and Diversion Structure works as per specification, accesory building & design approved by Engineer in Charge 54 Treated Effluent line (400mm Dia DI K7) (STP to Disposal point (Khow river) 55 Excavating trenches for pipes including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc., and disposing of surplus excavated soil as directed, within a lead of 50 m.0.0 to 1.5 mtr. Depth do - in all kindes of soil 56 Supply of 400mm dia. DI K7 pipe and special for the pumping mains including all complete Pipes conforming to IS : 8329- 400 mm 57 Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc.all complete required for completion of work (400mm dia) 58 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. all complete required for completion of work150 mm 59 Carting of 400mm dia DI K7 pipe and specials from store to the work lowering the same in to the trenches upto depth as specified below G.L. inclduing testing of pipes etc. 60 Providing & Constructing masonry Chamber 1.5x1.5x1.5 m inside, in brick work in cement mortar 1:3 (1 cement : 3 coarse sand) for valve, withcast insitu RCCslab with necessary reinforcment.The valve chamber shall be plastered with CM 1:4, A levelling coars of M10shall be provided.The cost is inclusive of excavation , disposal and construction of valve chamber with moduar bricks plasting with cement mortar with all lead and lift etc., as per specification & drawing. 61 Sluice valve, Air valve chambers 62 Dismantling/cutting of BOE road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m. 63 Reinstatement of BOE road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m. 64 E/M WORKS 65 STP ( 7.2 MLD ) And Co Treat ment Plant ( 7 KLD ) 66 A. Design, Supply of all Materials, Erection, Testing,Commissioning and 3 month trial run Of Electrical, Mechanical & Instrumentation Equipments at STP (7.2 MLD )with all required electrical& mechanical works, PLC/SCADA work, electrification & street lighting work and Online Continuous Effluent Monitoring System (OCEMS) etc. all complete as per tender documentfor STP.The effluent quality for agricultural uses ( PH-6.5 TO 8.3,SS-30 mg/l, Oil & Greases -10mg/l, BOD- 10mg/l,COD-30 mg/l,Residual Chlorine-nil, TKN-10mg/l, Nitrate-10mg/l, FC-230MPN/100ml Dissolved P-5mg/l (preferable 2mg/l).) shall be maintained as per CPHEEO mannuals Latest NGT norms for effluent discharge shall be adhered. The rate is Considered for SBR Technology. The STP shall be capable to treat the raw sewage having minimum concentrationmentiond in CPHEEO mannual. Firm has to complete Design, Supply, Erection, Testing,Commissioning and 3 month trial run of Substation Work like HT Panel, Transformer & its associated equipments and DG Set Work with AMF Panelwith considering load of STP and MPS both.B. Design, Supply of all Materials, Erection and Commissioning and 3 month Trial Run of Co-Treatment Plant ( 7 KLD ) having manual screen with-SS 304 with bar size (50 mm x 10mm) and gaping 20 mm, Screw Pumps (2 Kl/h 1W+1S), Screw Press Machine (3 KL/H) with double cylinder having VFD for its operation , 1000 Lit. PVC tank for washing screw press machine. all type pipe and fittings, LT panel and cabling material,Dewatering Pumps (1W+ 1S), 2HP Blower with 6 Nos Diffusers etc complete. including Supply and 3 month trial run of 1 No. 1500 Lit. Cesspool Vehicle having 30 HP Reputed make Tractor (with Registration Certificate and insurance papers) 67 E./M. Works at MPS 68 Electrical Works 69 H.T.Panel( Comprising with 1 -I/C and 2 -O/G. (panels should be TYPE TESTED ASSEMBLY ( TTA) type only) 70 SITC of Indoor Type Floor mounted HT Panel with11 KV, 630/800 Amps 3 phase, 50 Hz Vacuum Circuit Breaker (VCB) Panel Fabricated by System Integrator of VCB Manufacturer as per IEC 62271-1,100,200 Standard made from Powder painted pre-fabricated, CRCA sheet steel /High quality Aluminium-Zinc (Aluzinc) coated sheet steel. Fabrication shall be done through CNC turret press and CNC bending machine having a rupturing capacity of 500 MVA, 26.3 KA breaking capacity for 3 sec, Internal arc type tested for 26.3KA for 1 sec with AFLR clasification with suitable capacity of bus bar connected with the incoming and outgoing panels as per given details- 71 Supply installation testing and commissioning of Incoming Panel comprising of following: - VCB 630/800 Amps . VI of VCB should be sealed for 30000 operation. VCBoperationg mechanism should be of M2 duty for minimum 10000 mechanicaloperation. - Closing & tripping coil of VCB should be of continious rating to achive minimal failure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement)- VT Ratio: 11KV/1.732/110V/1.732/110V/1.732, -Core 1: 0.5, 20VA should be floor mounted and to be connected from the back side of the panel.- Numerical relay (should be VCB manufacturers own make) having protections of 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input , programable 6 Digital Output and programable 4 nos. LED at HMI.- Ammeter with Selectorswitch and Volt meter with Selector switch- Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA,KVAR, PF, KWH, KVARH, KVAH, A,V etc.- Trip circuit supervision relay (feature of numerical relay)- LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) and 8/12 window Annunciator. (1set, included in STP costing) 72 Supply Installation Testing and Commissioning Outgoing Panel comprising of following: - VCB 630/800 Amps . VI of VCB should be sealed for 30000 operation. VCBoperationg mechanism should be of M2 duty for minimum 10000 mechanicaloperation. - Closing & tripping coil of VCB should be of continious rating to achive minimalfailure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement)- Numerical relay (should be VCB manufacturers own make) having protectionsof 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input ,programable 6 Digital Output and programable 4 nos. LED at HMI.- Ammeter with Selectorswitch and Volt meter with Selector switch- Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA,KVAR, PF, KWH, KVARH, KVAH, A,V etc.- Trip circuit supervision relay (feature of numerical relay)- LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) (2 sets, included in STP costing) 73 Providing & Laying XLPE insulated as per IS:7098/II/85 H.T.cable as per PWD specification for electrical Works for working voltage 11 K.V.(E) in existing RCC / Hume /Stoneware / PVC pipe/ open duct/cable trench, on existing cable trays or on surface etc. including making necessary connection, testing etc. (included in STP costing)3 core X 120sq.mm. armored HT Cable (From HT Panel to Transformers) -60 metersTrench making and covering of trench in all respect.- 60 metersSITC of 11 KV End Termination Kit Indoor type (3 core, 120sq.mm) - 4 sets11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage 45 KV - 2.5 SqmTransformer:Suitable capacitywith Off -LTC (+5% to - 10% @ 2.5%) : S I T C of star rated Copper wound distribution Transformer of suitable capacity rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & losses as defined as per IS 1180 part I 2014. including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect. (included in STP costing) -- 2 Nos. 74 L.T. Panel (panels should be TYPE TESTED ASSEMBLY ( TTA) type only)SITC of 0.415 kV L.T. control panel for pumping plant-L.T. control panel suitable to operatedon 415 ± 6 %volt , 3 Phase , 50 Hz, AC supply as per details given below-(A) 2 Nos incoming ACB panels and 1 outgoing ACB panel, each consisting of following items -(i) 4 pole Microprocessor based release Draw out type ACB (Motorised charging type) ,630 A Rating ,50 kA- 1 No.(ii)C.Ts of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Voltmeter with selector switch- 1 No. (v)Power factor meter(0.5 Lag&0.5Lead) - 1 No.(vi)Frequency meter-1 No.(vii)KWH meter - 1 No. (viii)2 Pole over current relay& one pole earth fault relay - 1 No.(B)Bus bar chamber having 3 Nos. bus bars for phase and 1 No. bus bar for neutral of suitable size – 1 No. (C) 6 Nos. composite panels for pumping plants, each consisting of following items –(i) 4 pole MCCB 63 A current rating, 50 KA short circuit breaking capacity With Microprocessor based release with adjustableadjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection -1 No.(ii)C.Ts. of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Automatic start / stop device according to level in the sump- 1 No.(v)Indicating lamps(Auto/manual/low level/ reverse rotation) - 1 Set (D) 3 Nos. outgoing panels for miscellaneousworks, each consisting of following items – (i) MCB of 40 A capacity- 1 No.(ii) C.Ts. of suitable ratio- 1 No. (iii) Ammeter with selector switch - 1 No.(iv) Indicating lamps- 1 Set (E)APFC Panel for total load.(F) 4 pole Microprocessor based release Draw out type (Motorised charging type) ,630 A Rating ,50 kA Panel for DG sets incoming - 1 NO (G) Bus coupler arrangement in panels 75 LT Cable laying and jointing 76 Power and control cable-Supply of 185 sq. mm 3.5 core cable - 2 Run required for power fromeach Transformer to each L.T. panel , 50 sq. mm X3 core-1 run cable for power from starters to Motor including lugging and jointing, laying, trench excavation and compaction as well as complete cabling of automation systemetc. complete in all respect. 77 Earthing 78 Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. 79 Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. B class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, BottomDia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge. 80 Supply & Laying of 50mmX6mm size GI earth strip in horizontal or vertical run in ground/surface/recess including riveting,soldering, saddles, Jointing shall be done by overlapping and with 2 set of GI nut bolt & spring washer spaced at 50cm making connection etc.(20meter for each earthing) 81 Charges of Electrical safety Clearance 82 Expenditure on B&L Form, Challan etc. 83 Proper fencing of substation portion as per I.E. rules. (Ref. Ongoing AMRUT Work Aligarh Sewarage) 84 STARTER PANEL 85 SITC of Compraising of Soft Starter, suitable to meet the basic requirement of motor protections and suitable to run 20 HP motor (To be fixed in composite panel of LT Panel) 86 Mechanical Works 87 PumpThesubmersible non clog pumpset should be single stage having two vanes enclosedimpellercoupled with submersible motor of 20 HP Rating 400 Volt ±10%,3 phase 50 Hz, solid handling capacity 125mm, suitable to pump raw sewage with an specific gravity 1.03 having following construction of material with 10 Met. cable as offered. (4W+2S)Casing-2% Ni Cl. IS.210 grade F.G.220 with hardness 275 BHN.Impeller-Stainless steel CF-8Mshaft-stainless steel AISI-410Discharge of pump= 3110 lpmTotal Head= 16 M or as per designSpeed=980Quantity of pumps. 88 Guid Rail System 89 Guide rail system (Automatic coupling system) for 20 HP submersible pump setscomplete for above pump set.(6 Sets, included in item no. 51.01) 90 Lifting Chain , MOC- alloy steel, lifting chain with oval ring @ 1m & with D/Bow shackle (6 Sets, included in item no. 51.01) 91 Main piping and Valves.Main piping and valves 200 mm dia delivery, 350 mm diacommon header line. 92 Valves.Confirming to IS 780/2906 or as applicable PN rating- 1.0Type of liquid to be handled-potable water 93 Material of constructionBody-CI,IS-210 grade FG 200Wedge-CI IS210 Grade FG200Spindle-Stainless steel AISI304Sheet and face Ring-SS ASTMA 743 Grade C.F.8 MChannel& Shoe-S.S.AISI,.304Drain& Air plug-S.S.AISI.304Bushing arrangement-Halprene on bronzeRivets-AISI:304Fasteners-MS 94 Motor Operated Sluice Valves 95 Sluice Valve 200 mm dia 96 Sluice Valve 350 mm dia 97 Reflux Valve 98 Reflux valve 200 mm dia N.B. 99 PipingsNote : Regarding the size of pipes, Tee, Bend etc, contrctor is required to designed them self and may got it approved by the department before execution of works along with layout drawing taking 200mm pipe 60m and 350 mm pipe 15m . 100 200 mm, K9 delivery pipes for all six pumping plant 101 350 mm, K9 common header pipes 102 Specials like bend, tee, D Joint etc. 103 Nut Bolt, Washer Rubber packing etc 104 INSTALLATION, TESTING & COMMISSIONING 105 Installation & Commissioning of all 6 Nos. Pump set,Piping & Valves as mentioned in above. 106 Level Transmitter (For Hi-Lo cut-off & alarms) 107 SITC of Radar type level transmitter shall be provided in the pump house for measuring the sewage level in wet sump. The indicator shall be digital type showing depth in meters and shall be capable for input to PLC or HMI touch sceen for display. 108 Electro magnetic flow meter 109 SITC of CE/UL certified Electro magnetic flow metersuitable to measure 0 to 30 MLD flow to be fitted in 350 mm dia main header line. 110 E.O.T. Crane 111 SITC of 3 Tonn E.O.T. crane providing, erecting and commissioning single girder electrically operated rectangular over head travelling crane with 6 m lift complete with wire rope hoist, class II duty, all three motions electrically operated by suitable rating motor IP 54, control panel and down pendent control block. 112 Chequerred plate and guards 113 SITC of 3mm thick M.S chequerred plate over all the run of cables trenches to cover properly and M.S. grill and M.S. guard over all pipes ducts and other point where required as per site condition (Ref. UP Jal Nigam, GM Gzb Rate) (3X0.75+3X0.9+7X0.6+1X0.9)X1=10.05sqmm. 114 PAINTING 115 Painting of all pumps piping and valves with two coat enamel paint. 116 LIGHT WIRING & Electrification (Ref. UP Jal Nigam E&M SOR, 2019) 117 Complete Internal Electrification of LT Panel room with 2 Nos. Exhaust Fan 118 Complete Internal Electrification of HT Panel room with 2 Nos. Exhaust Fan 119 IPS Campus with Solar Panel and LED Light of 3 sets. 120 D.G. SET AND ACCESSORIES 121 SITC of Radiator Cooled and Turbo charged Silent type suitable capacity DG set , engine ,alternator capable of developingat 415+6%, 50 Hz AC at 0.85 P.F. lagging and self exciting coupled with suitable BHP diesel engine through flexible coupling and mounted on common base plate complete with fuel tank inside the acousting system and inbuilt control panel, Governor, Manual & electric Start , Batteries with battry charger, Engine instruments panel,AVM pads, All controls for operationof DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessiblefrom outside. T , 3 Met exhaust pipe, D.G. set shall be mounted under open sky resting on the foundation as per design. (1 set, included in stp costing) 122 SITC of PLC Based Auto main failure (AMF) Panel forDG Set fabricated from CRCA sheet steel 2 mm Thick , Powder coated finish , Engine Start & Stop commands, control Relays , Ammeter & Voltmeter with selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, operator interface panel complete in all respect.(1 Set, included in stp costing) 123 Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. B class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 withperforated holes of 12 mm dia ,including all accessories like nut, bolts,reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required.(2 Job, included in stp costing) 124 Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance for value of 5 ohms or less as required. (2 Jobincluded in stp costing) 125 Supply & Laying 50 mm X 6mm sizeGI earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. (1 Job, included in stp costing) 126 Providing and Laying cable for DG Set to Panel ( armored aluminium )-(1 Job, included in stp costing) 127 Supplying and making one end termination with heavy duty brass compression gland (as per IS 12943- 1990) SIBG type, heavy duty aluminium lugs (as per IS 8309 - 1993 & IS 8337-1976 ) duly crimped with crimping tool, PVC tape as per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade for 3.5 core X 185 sq mm. (4 Jobs, included in stp costing) 128 SCREENS AND GATES: 129 Rising type thimble mounted CI Sluice Gates of reputed make at IPS 130 Stainless steel Manual Bar Screen having bar size 50mmx10mm with (20 mm gaping) at mid year peak discharge (1w+ 1s) 131 Packing and Frieght 132 Installation, Testing and Commissioning 133 AUTOMATION OF MPS 134 CE& UL certified PLC/RTU with redundant CPU & power supply in IP 54 enclosure suitable to communicate with GSM based modem unit with redundant CPU & power supply with annalog & digital paramter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification including full developed version of scada software with customization of software with laptop/desktop etc to monitor and control the ips from remote places. 135 GSM/GPRS based wireless communication with 4G modem for RTU/PLC capable to transfer & gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification. 136 CE/UL certified intellignet Smart Energy Meter 137 Auto phase reversal unit with inbuilt time delay & enclosure (confirm to IEC-60947-1 & IEC-60947-b-1) 138 160 AMP rating 139 Electronic sensor type pressure measuring device suitable for pressure measurements of sewage flow in delivery and common header line. The material of construction of housing and other parts in contact with sewage shall be of stainless steel. These shall be of required protection category and complete with signal transmitting device and digital pressure indicator. 140 CE/UL Certified Surge protector for control panel. 141 CE/UL Certified 7 HMI touch screen suitable to communication with PLC/RTU for local display & control ofp rocess parameters. 142 Security Survillance IP Camera with recorder 143 Installation, commissiong & testing of above automation work 144 Expenditure on Operation & Maintenance of MPS including automation, Diesel Consumption & Electricity Consuption During 3 month Trial and Run Period 145 E./M. Works at IPS Dhampur 146 Electrical Works 147 H.T.Panel( Comprising with 1 -I/C and 2 -O/G .(panels should be TYPE TESTED ASSEMBLY ( TTA) type only)SITC of Indoor Type Floor mounted HT Panel with11 KV, 630/800 Amps 3 phase, 50 Hz Vacuum Circuit Breaker (VCB) Panel Fabricated by System Integrator of VCB Manufacturer as per IEC 62271-1,100,200 Standard made from Powder painted pre-fabricated, CRCA sheet steel /High quality Aluminium-Zinc (Aluzinc) coated sheet steel. Fabrication shall be done through CNC turret press and CNC bending machine having a rupturing capacity of 500 MVA, 26.3 KA breaking capacity for 3 sec, Internal arc type tested for 26.3KA for 1 sec with AFLR clasification with suitable capacity of bus bar connected with the incoming and outgoing panels as per given details- 148 Supply installation testing and commissioning of Incoming Panel comprising of following: - VCB 630/800 Amps . VI of VCB should be sealed for 30000 operation. VCBoperationg mechanism should be of M2 duty for minimum 10000 mechanicaloperation. - Closing & tripping coil of VCB should be of continious rating to achive minimal failure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement)- VT Ratio: 11KV/1.732/110V/1.732/110V/1.732, -Core 1: 0.5, 20VA should be floor mounted and to be connected from the back side of the panel.- Numerical relay (should be VCB manufacturers own make) having protections of 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input , programable 6 Digital Output and programable 4 nos. LED at HMI.- Ammeter with Selectorswitch and Volt meter with Selector switch- Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA,KVAR, PF, KWH, KVARH, KVAH, A,V etc.- Trip circuit supervision relay (feature of numerical relay)- LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) and 8/12 window Annunciator. 149 Supply Installation Testing and Commissioning Outgoing Panel comprising of following: - VCB 630/800 Amps . VI of VCB should be sealed for 30000 operation. VCBoperationg mechanism should be of M2 duty for minimum 10000 mechanicaloperation. - Closing & tripping coil of VCB should be of continious rating to achive minimalfailure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement)- Numerical relay (should be VCB manufacturers own make) having protectionsof 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input ,programable 6 Digital Output and programable 4 nos. LED at HMI.- Ammeter with Selectorswitch and Volt meter with Selector switch- Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA,KVAR, PF, KWH, KVARH, KVAH, A,V etc.- Trip circuit supervision relay (feature of numerical relay)- LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) 150 Providing & Laying XLPE insulated as per IS:7098/II/85 H.T.cable as per PWD specification for electrical Works for working voltage 11 K.V.(E) in existing RCC / Hume /Stoneware / PVC pipe/ open duct/cable trench, on existing cable trays or on surface etc. including making necessary connection, testing etc. 151 3 core X 120sq.mm. armored HT Cable (From HT Panel to Transformers) 152 SITC of 11 KV End Termination Kit Indoor type (3 core, 120sq.mm) 153 11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break DownVoltage 45 KV 154 Transformer: 315 KVA with Off -LTC (+5% to - 10% @ 2.5%) : S I T C of star rated Copper wound distribution Transformer of 315 KVA rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & losses as defined as per IS 1180 part I 2014. including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect. 155 L.T. Panel (panels should be TYPE TESTED ASSEMBLY ( TTA) type only) 156 SITC of 0.415 kV L.T. control panel for pumping plant-L.T. control panel suitable to operatedon 415 ± 6 %volt , 3 Phase , 50 Hz, AC supply as per details given below-(A) 2 Nos incoming ACB panels and 1 No outgoing ACB panel, each consisting of following items -(i) 4 pole Microprocessor based release Draw out type ACB (Motorised charging type) ,630 A Rating ,50 kA- 1 No.(ii)C.Ts of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Voltmeter with selector switch- 1 No. (v)Power factor meter(0.5 Lag&0.5Lead) - 1 No.(vi)Frequency meter-1 No.(vii)KWH meter - 1 No. (viii)2 Pole over current relay & one pole earth fault relay - 1 No.(B)Bus bar chamber having 3 Nos. bus bars for phase and 1 No. bus bar for neutral of suitable size – 1 No. (C) 3 Nos. composite panels for pumping plants, each consisting of following items –(i) 4 pole MCCB 400 A current rating, 50 KA short circuit breaking capacity With Microprocessor based release with adjustableadjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection -1 No.(ii)C.Ts. of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Automatic start / stop device according to level in the sump- 1 No.(v)Indicating lamps(Auto/manual/low level/ reverse rotation) - 1 Set (D) 2 Nos. composite panels for pumping plants, each consisting of following items –(i) 4 pole MCCB 100 A current rating, 50 KA short circuit breaking capacity With Microprocessor based release with adjustableadjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection -1 No.(ii)C.Ts. of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Automatic start / stop device according to level in the sump- 1 No.(v)Indicating lamps(Auto/manual/low level/ reverse rotation) - 1 Set (E) 3 Nos. outgoing panels for miscellaneousworks, each consisting of following items – (i) MCB of 40 A capacity- 1 No.(ii) C.Ts. of suitable ratio- 1 No. (iii) Ammeter with selector switch - 1 No.(iv) Indicating lamps- 1 Set (F)APFC Panel for total load.(G) 4 pole Microprocessor based release Draw out type (Motorised charging type) ,630 A Rating ,50 kA Panel for DG sets incoming - 1 NO (G) Bus coupler arrangement in panels 157 LT Cable laying and jointing 158 Power and control cable-Supply of 240 sq. mm 3.5 core cable - 2 Run required for power fromeach Transformer to each L.T. panel , 240 sq. mm X3 core-1 run cable for power from starters to 67 KW Motors & 35 sq. mm X3 core-1 run cable for power from starters to 15 KW Motors including lugging and jointing, laying, trench excavation and compaction as well as complete cabling of automation systemetc. complete in all respect. 159 Earthing 160 Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. 161 Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. B class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge. 162 Supply & Laying of 50mmX6mm size GI earth strip in horizontal or vertical run in ground/surface/recess including riveting,soldering, saddles, Jointing shall be done by overlapping and with 2 set of GI nut bolt & spring washer spaced at 50cm making connection etc.(20meter for each earthing) 163 Charges of Electrical safety Clearance 164 Expenditure on B&L Form, Challan etc. 165 Proper fencing of substation portion as per I.E. rules. (Ref. Ongoing AMRUT Work Aligarh Sewarage) 166 STARTER PANEL 167 SITC of Compraising of Soft Starter, suitable to meet the basic requirement of motor protections and suitable to run 90 HP motor (To be fixed in composite panel of LT Panel) 168 SITC of Compraising of Soft Starter, suitable to meet the basic requirement of motor protections and suitable to run 20 HP motor (To be fixed in composite panel of LT Panel) 169 Mechanical Works 170 Large PumpsThesubmersible non clog pumpset should be single stage having two vanes enclosedimpellercoupled with submersible motor of 90 HP Rating 400 Volt ±10%,3 phase 50 Hz, solid handling capacity 125mm, suitable to pump raw sewage with an specific gravity 1.03 having following construction of material with 10 Met. cable as offered. (2W+1S)Casing-2% Ni Cl. IS.210 grade F.G.220 with hardness 275 BHN.Impeller-Stainless steel CF-8Mshaft-stainless steel AISI-410Discharge of pump= 5750 lpmTotal Head= 40 M or as per designSpeed=980Quantity of pumps. 171 Guid Rail System 172 Guide rail system (Automatic coupling system) for 90 HP submersible pump setscomplete for above pump set.(3 Sets, included in item no. 94.01) 173 Lifting Chain , MOC- alloy steel, lifting chain with oval ring @ 1m & with D/Bow shackle (3 Sets, included in item no. 94.01) 174 Small Pumps 175 Thesubmersible non clog pumpset should be single stage having two vanes enclosedimpellercoupled with submersible motor of 20 HP Rating 400 Volt ±10%,3 phase 50 Hz, solid handling capacity 125mm, suitable to pump raw sewage with an specific gravity 1.03 having following construction of material with 10 Met. cable as offered. (1W+1S)Casing-2% Ni Cl. IS.210 grade F.G.220 with hardness 275 BHN.Impeller-Stainless steel CF-8Mshaft-stainless steel AISI-410Discharge of pump=2500 lpmTotal Head= 17 MSpeed=980Quantity of pumps. 176 Guid Rail System 177 Guide rail system (Automatic coupling system) for 20 HP submersible pump setscomplete for above pump set. (2 Sets, included in item no. 98.01) 178 Lifting Chain , MOC- alloy steel, lifting chain with oval ring @ 1m & with D/Bow shackle (2 Sets, included in item no.98.01) 179 Main piping and Valves. 180 200 mm dia delivery for small pumps and250 mm dia delivery for large pumps, 350 mm diacommon header line. 181 Valves.Confirming to IS 780/2906 or as applicable PN rating- 1.0Type of liquid to be handled-potable water 182 Material of constructionBody-CI,IS-210 grade FG 200Wedge-CI IS210 Grade FG200Spindle-Stainless steel AISI304Sheet and face Ring-SS ASTMA 743 Grade C.F.8 MChannel& Shoe-S.S.AISI,.304Drain& Air plug-S.S.AISI.304Bushing arrangement-Halprene on bronzeRivets-AISI:304Fasteners-MS 183 Motor Operated Sluice Valves 184 Sluice Valve 200 mm dia 185 Sluice Valve 250 mm dia 186 Sluice Valve 350 mm dia 187 Reflux Valve 188 Reflux valve 200 mm dia N.B. 189 Reflux valve 250 mm dia N.B. 190 PipingsNote : Regarding the size of pipes, Tee, Bend etc, contrctor is required to designed them self and may got it approved by the department before execution of works along with layout drawing . 191 200 mm, K9 delivery pipes for small pumping plants 192 250 mm, K9 delivery pipes for large pumping plants 193 350 mm, K9 common header pipes 194 Specials like bend, tee, D Joint etc. 195 Nut Bolt, Washer Rubber packing etc 196 INSTALLATION, TESTING & COMMISSIONING 197 Installation & Commissioning of allPump set,Piping & Valves as mentioned in above @5% of supplied items. 198 Level Transmitter (For Hi-Lo cut-off & alarms) 199 SITC of Radar type level transmitter shall be provided in the pump house for measuring the sewage level in wet sump. The indicator shall be digital type showing depth in meters and shall be capable for input to PLC or HMI touch sceen for display. 200 Electro magnetic flow meter 201 SITC of CE/UL certified Electro magnetic flow metersuitable to measure 0 to 30 MLD flow to be fitted in 350 mm dia main header line. 202 E.O.T. Crane 203 SITC of 3 Tonn E.O.T. crane providing, erecting and commissioning single girder electrically operated rectangular over head travelling crane with 6 m lift complete with wire rope hoist, class II duty, all three motions electrically operated by suitable rating motor IP 54, control panel and down pendent control block. 204 Chequerred plate and guards 205 SITC of 3mm thick M.S chequerred plate over all the run of cables trenches to cover properly and M.S. grill and M.S. guard over all pipes ducts and other point where required as per site condition(3X0.75+3X0.9+7X0.6+1X0.9)X1=10.05sqmm. 206 PAINTING 207 Painting of all pumps piping and valves with two coat enamel paint. 208 LIGHT WIRING & Electrification (Ref. UP Jal Nigam E&M SOR, 2019) 209 Complete Internal Electrification of LT Panel room with 2 Nos. Exhaust Fan 210 Complete Internal Electrification of HT Panel room with 2 Nos. Exhaust Fan 211 IPS Campus with Solar Panel and LED Light of 3 sets. 212 D.G. SET AND ACCESSORIES 213 SITC of Radiator Cooled and Turbo charged Silent type DG set , engine ,alternator capable of developing 250 kVA at 415+6%, 50 Hz AC at 0.85 P.F. lagging and self exciting coupled with suitable BHP diesel engine through flexible coupling and mounted on common base plate complete with fuel tank inside the acousting system and inbuilt control panel, Governor, Manual & electric Start , Batteries with battry charger, Engine instruments panel,AVM pads, All controls for operationof DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessiblefrom outside. T , 3 Met exhaust pipe, D.G. set shall be mounted under open sky resting on the foundation as per design. 214 SITC of PLC Based Auto main failure (AMF) Panel for 250 KVA DG Set fabricated from CRCA sheet steel 2 mm Thick , Powder coated finish , Engine Start & Stop commands, control Relays , Ammeter & Voltmeter with selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, operator interface panel complete in all respect. 215 Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. B class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 withperforated holes of 12 mm dia ,including all accessories like nut, bolts,reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, BottomDia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required. 216 Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance for value of 5 ohms or less as required. 217 Supply & Laying 50 mm X 6mm sizeGI earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. 218 Providing and Laying cable for DG Set to Panel 240 sq mm X 3.5 core x 2 run( armored aluminium ). 219 Supplying and making one end termination with heavy duty brass compression gland (as per IS 12943- 1990) SIBG type, heavy duty aluminium lugs (as per IS 8309 - 1993 & IS 8337-1976 ) duly crimped with crimping tool, PVC tape as per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade for 3.5 core X 240 sq mm. 220 SCREENS AND GATES: 221 Rising type thimble mounted CI Sluice Gates of reputed make at IPS 222 Stainless steel Manual Bar Screen having bar size 50mmx10mm with (20 mm gaping) at peak load of full discharge (working) 223 Stainless steel Manual Bar Screen having bar size 50mmx10mm with (20 mm gaping) at peak load of full discharge( standby) 224 Packing and Frieght 225 Installation, Testing and Commissioning 226 AUTOMATION OF IPS 227 CE& UL certified PLC/RTU with redundant CPU & power supply in IP 54 enclosure suitable to communicate with GSM based modem unit with redundant CPU & power supply with annalog & digital paramter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification including full developed version of scada software with customization of software with laptop/desktop etc to monitor and control the ips from remote places. 228 GSM/GPRS based wireless communication with 4G modem for RTU/PLC capable to transfer & gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification. 229 CE/UL certified intellignet Smart Energy Meter 230 Auto phase reversal unit with inbuilt time delay & enclosure (confirm to IEC-60947-1 & IEC-60947-b-1) 231 160 AMP rating 232 Electronic sensor type pressure measuring device suitable for pressure measurements of sewage flow in delivery and common header line. The material of construction of housing and other parts in contact with sewage shall be of stainless steel. These shall be of required protection category and complete with signal transmitting device and digital pressure indicator. 233 CE/UL Certified Surge protector for control panel. 234 CE/UL Certified 7 HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters. 235 Security Survillance IP Camera with recorder 236 Installation, commissiong & testing of above automation work 237 3 month trial run of automation work 238 Expenditure on Operation & Maintenance of IPS during 3 month Trial and Run Period 239 Expenditure onDiesel Consumption of IPS during 3 month Trial and Run Period 240 Expenditure on Electricity Consuption of STP, MPS & IPS as per actual UPPCL bill during 3 month Trial and Run Period
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
20.
Educational and Research Institute #10488347 Price Bid
Development Of Iot Lab At Nsut East Campus Geeta Colony, Delhi 110031--- 1 Civil Work: 1 Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms / Sqm ( Both Side Inclusive ) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37Mm, At1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50Mm Long With 6Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall / Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C / C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per AnufacturerS Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With :12.5 Mm Thick Tapered Edge Glass Reinforced Gypsum ( Grg ) Board Conforming To Is: 2095- ( Part 3 ) :1996 ( Boards With Bis Certification Marks ) 2 2 Providing & Fixing False Ceiling At All Heights With Grg ( Glass Fibre Reinforced Gypsum ) False Ceiling Tiles Of Size 595X595 Mm Of Approved Texture, Design And Patterns Having Moisture Content Less Than 2%, Humidity Resistance Of 99%, Nrc0.50 To 0.75 As Per Is 8225:1987, Non Combustible As Per Bs 476 ( Part 4 ) -1970 And Light Reflectance Of 85% ( Minimum ) To Be Laid In True Horizontal Level Suspended On Interlocking Metal T-Grid Of Hot Dipped Galvanised Iron Section Of 0.33Mm Thick ( Galvanized @ 120 Grams Per Sqm Including Both Sides ) Comprising Of Main-T Runners Of Size 15X32 Mm Of Length 3000 Mm, Cross - T Of Size 15X32 Mm Of Length 1200 Mm And Secondaryintermediate Cross-T Of Size 15X32 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600 Mm, Suspended From Ceiling Using Galvanisedmild Steel Items ( Galvanizing @ 80 Grams Per Sqm ) I.E. 50 Mm Long, 8 Mm Outer Diameter M-6 Dash Fasteners, 6 Mm Dia Fully Threaded Hanger Rod Upto 1000 Mm Length And L-Shape Level Adjuster Of Size 85X25x2 Mm.Galvanised Iron Perimeter Wall Angle Of Size 24X24x0.40 Mm Of Length 3000 Mm To Be Fixed On Periphery Wall / Partition With The Help Of Plastic Rawl Plugs At 450 Mm Center To Center And 40 Mm Long Dry Wall Wood Screws. The Work Shall Be Carried Out As Perspecifications, Drawing And As Per Directions Of The Engineer-In-Charge.With Semi Perforated 12 Mm Thick Micro Tegular Edged Grg False Ceiling Tiles. 3 3 Distempering With 1St Quality Acrylic Distemper, Having Voc ( Volatile Organic Compound ) Content Less Than 50 Grams / Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour.One Coat 4 4 Providing And Placing Of Modular Workstations System Of Size 1500Mm ( W1 ) X 1500Mm ( W2 ) X 600Mm ( D ) X 750 Griha Compliant Having Following Specifications. - Main Partition Panel Having 4 Horizontal Blocks And Consists Of Vertical Extrusions 2Nos And Horizontal Extrusions 5 Nos Made Of 1.2Mm Thick Aluminium With Duly Powder Coated At Every Division Of Tile / Block. Each Panel Shall Have Bottom Frame Fabricated For 52.4Mm Panel Comprises Of 2 Nos. L-Channels Made Of 2Mm Thick Crca ( Cold Rolled, Cold Aneeled ) Steel ( Is: 513 ) , Formed Plates Of 3Mm Thick Hot Rolled Steel ( Is: 2062 ) & Erw Steel Tube Of Size 35X15x1.6Mm Thick In Oval Cross Section ( Is: 7138 ) Welded Together. The Complete Bottom Frame Shall Be Powder Coated With An Average Of 50-60 Microns Thickness Of Epoxy Powder Coating. The Bottom Frame Is Bolted With The Upright Verticals. Each Panel Is Provided With 2Nos Legs Of Height 120Mm Are Fixed At The Bottom Frame Of The Panel. Legs Construction-Adjustment Of The Height By 50Mm. It Will Be Coated With 45-50Micron ------------------------ Locking:10 Lever Cam Lock & Central Rh Locking With Actuator & Lock Channel Mechanism. Top Panel : 0.8Mm Thick Metal Straight Edge Top. Castors : Swiveling Non-Lockable 4Nos Castors Mounted Below The Body Shell. The Total Drawer Unit Is Finished With Epoxy Polyester Powder Coated To The Thickness Of 50 Microns ( + / -10 ) . The Product Should Be Complete And As Per Approved Sample And As Per The Direction Of Engineer-In-Charge. 5 Supplying And Placing In Position Faculty Table Of Following Specifications. Overall Dimension Of The Main Desk Shall Be - 1800Mmw X 750Mmd X 1050Mm Hthe System Shall Be A Desk-Based System With A Platform Understructure Made Up Of A Combination Of Ms. Tubes And Plates. The Product Should Be Greenpro Certified And Should Be Listed In Griha Product Catalogue In The Following Category Griha V.3 Criteria: 34; Griha V.2015 Criteria: 31 & Svagriha Criteria: 14. Understructure - The Slanted Legs Are Connected To The Understructure With The Help Of Pdc Connectors To Provide A Stable And Sturdy Base For The Worktops. Modesty Panel Shall Be Of Acrylic ( 8 Mm Thick Acrylic Both Side Frosted ) Or Of Metal 1.2 Mm Thick Crca. Worktop - Worktop Shall Be Made Of 25Mm Thick Pre-Laminated Board Conforming To Is: 12823. All The Edges Of Work Surface Shall Be Provided With Machine Pressed 2 Mm Thick Pvc Lipping Glued With Hot Melt Eva Glue.The Worktop Shall Be Complete With Provisions For Screen Mounting As Well As For Wire Management On The Workstation. Provisions For Fixing Of The Switches Shall Be On The Wire Tray / Channel. A Wire Management - It Shall Be A Part Of The Understructure And Can Be In The Form Of Enclosed Metal Tray Or 2 Level Enclosed Channel To Provide Concealed Wire Management Throughout The Cluster Formation. Wire Riser Leg Or Independent Wire Risers Shall Be Provided As Per The Layout Structure.Ccess Flaps With Soft Closing Technology Shall Be Provided On The Table Tops To Access The Switch Points On The Tray. Pedestal Having 3 Drawers Unit Having Flat Metal Front And Top With Central Locking. The Drawer Unit Consists Of 2Box And 1File Drawers. The Overall Size Of The Drawer Units Is 450Mm ( W ) X 435Mm ( D ) X 646Mm ( H ) . Construction & Material Of Drawer Unit :Welded Assembled Of 0.8Mm Thick Crca For Body Shell, Drawer Front & Tray, Front Side Stiffener, Rear Side Stiffener & Bottom, 1.2Mm Thick Crca Top Stiffene, Bottom Stiffener, Drawer Fronts & Metal Front Straight Edge. All Drawers With Double Extension Precision Ball Slide Shall Be Provided. For Drawer Pulling, Side Wise Tapered Recess Provided In Shell Behind Drawer Fronts. Locking:10 Lever Cam Lock & Central Rh Locking With Actuator & Lock Channel Mechanism. Top Panel : 0.8Mm Thick Metal Straight Edge Top. Castors : Swiveling Non-Lockable 4Nos Castors Mounted Below The Body Shell. The Total Drawer Unit Is Finished With Epoxy Polyester Powder Coated To The Thickness Of 50 Microns ( + / -10 ) . 6 6 Supplying And Placing Stool Of Following Specifications:The Seat Shall Be Made Up Of 1.2±0.1Cm Thick Flat Plywood With Moulded Polyurethane Foam And Are Upholstered With Replaceable Synthetic Leather Covers. The Dimensions Of Seat Shall Be Diameter 40.0 Cm And Adjustments Are 360° Revolving Type. The Back Foam Shall Be Designed With Contoured Lumbar Support For Extra Comfort. The Upholstery Shall Be Available In Synthetic Leather. The Dimensions Of Back Shall Be 45.0 Cm ( W ) Covered With Polyurethane Foam. The Hr Polyurethane Foam Shall Be Moulded With Density = 45 + / -2 Kg / M3and Hardness Load 16 ± 2 Kgf As Per Is:7888 For 25% Compression. The Manual Height Adjustment Shall Be Very Easy To Operate With A Help Of A Knob. It Should Be Easily Locked At The Most Comfortable Position. The Five-Prong Pedestal Shall Be Fabricated From 0.2 ± 0.02 Cm Thick Hr Sheet ( Is : Dd 1079 / Hr ) , Powder Coated ( Dft 40-60 Microns ) And Shall Be Fitted With An Injection Moulded Black Polypropylene Hub Cap And 5 Nos. Twin Wheel Castors. The Pedestal Shall Be 55.0±0.5Cm Pitch-Circle-Diameter ( 65.0±-1.0Cm With Castors ) , Circular-Foot-Ringof Dia 52.0±0.2Cm Shall Be Made Up Of Dia 1.9±0.2 X0.12±0.0096Cm Thk Ms Erw Tube For Foot Support In High-Base Stool.The Twin Wheel Castors Shall Be Injection Moulded In Black Nylon. Overall Dimensions Shall Bewidth- 65.0Cm, Depth- 65.0 Cm, Height- 88.0 To 99.5 Cm, Seat Height- 67.0 To 78.5 Cm. 7 7 Supplying And Placing Revolving Chair With The Cushioned Seat Assembly Consists Of Seat Base Moulded In Glass-Filled Poly-Amide, Moulded Polyurethane Foam & Upholstered With High Stretch Knitted Polyester Fabric. The Cushioned Back Assembly Consists Of Back Inner Moulded In Polypropylene In-Situ Moulded With Polyurethane Foam & Upholstered With High Stretch Knitted Polyester Fabric.* Full Back Size : 45.5 Cm. ( W ) X 53.0 Cm. ( H ) *Seat Size :48.5 Cm. ( W ) X 47.0 Cm. ( D ) The Hr Polyurethane Foam Used In Seat And Back Cushion Is Moulded In Density 45±2 Kg / M3, And Hardness Load 16 ± 2 Kgf As Per 15:7888 For 25% Compression.The Seat And Back Are Firmly Connected To The Base Frame And Are Cantilevered In Such A Way That It Gives A Multi-Dimensional Movement Possibility Just With A Simple Lean On The Sides Or Back, Without Need For Complex Manual Adjustments. The Cantilevered Seat Offers Impact Cushioning While Sitting And Synchronises With The Back Movement During Posture Changes. The 5 Shaped Spines Moulded In High Strength Glass-Filled Poly-Amide And The Spine Connector Moulded In Glass-Filled Poly-Am ) De Form The Back-Spine Structure Involved In Multi-Dimensional Recline Motion.The Variable Tilt Angle Recline Motion Can Be Adjusted With 3 Position Tilt Limit Feature Which Is Inbuilt In Seat Base And The Tension ( Return Force ) Is User Weight Dependent. The Assembly Consists Of Armrest Housing Sliding Over The Armrest Structure, Both Moulded In Glass-Filled Poly-Amide. The Height Adjustment Feature Is Button Operated Having Adjustment Of 6.6±0.5Cm. The Armrest Top Is Made Up Of Integral Skin Pu Moulded Over Plastic Inner Moulded In Glass-Filled Poly-Amide.The Seating Height Can Be Adjusted With A Pneumatic Gas-Lift Having An Adjustment Stroke Of 9.2 ± 0.3 Cmthe Pedestal Is Injection Moulded In Glass-Filled Poly-Amide And Fitted With 5 Nos. In Wheel Castors. The Pedestal Is 66.0±0.5 Cm. Pitch Centre Diameter And 76.0±1.0 Cm. With Castors. 5 Nos. Twin Wheel Castors Are Injection Moulded In Poly-Amide Having 5.0±0.1Cm Heel Diameter And Assembled To The Pedestal. The Product Shall Be From One Of The Approved Make Of Godrej, Hermanmiller, Steel Case, Delform Or Vitra Only. 8 8 Supplying And Placing Almirah Of Following Specifications : Almirah Steel Shall Have An Overall Size Of916mm ( W ) X486mm ( D ) X1980mm ( H ) With Welded Construction. It Should Have The Shelf Thickness Of 0.7 Mm, Back Thickness Of 0.8Mm, Door Thickness Of 0.8Mm ( High Yield Strength ) And All Other Components Shall Have A Thickness Of 0.9Mm. These Components Shall Be Made Of Crca ‘D’ Grade High Yield Strength As Per Is:513. The Almirah Steel Should Have A Mazak Handle And Three Way Locking Mechanism With Shooting Bolts. It Should Have A Height Wise Adjustable Shelf Mounting Which Shall Have A Uniformly Distributed Load Capacity Of Max 40 Kg. It Should Also Have A M10 Screw Type Leveller With Hex Plastic Base. The Finishing Shall Include Epoxy Powder Coated To The Thickness Of 50 Microns ( + / - 10 ) . Plenty Of Colour Options And Shelving Options Shall Be Available. 9 9 Supplying And Placing Locker Of Following Specificationsoverall Size Of 4 Door Locker Shall Be 380Mm ( W ) X450mm ( D ) X1830mm ( H ) .Stackability Shall Have Add- On Units That Can Be Stacked Width Wise To Form Bank Of Lockers Having Common Side Panel. Locking Shall Have 10 Lever Cam Lock With Lock Lever Plus Option Of Hasp Arrangement . Material Shall Be Crca 0.6 Mm Thickness . Construction Shall Be Rigid Knockdown Construction , Shelf Shall Be Uniformly Distributed Load Capacity Per Each Shelf Level Is 35 Kg Maximum . Finish Shall Be Epoxy Polyester Powder Coated To The Thickness Of 50 Microns . Handle / Label Holder Shall Be Aesthetically Appealing Snap Fit Absplastic Handle . Ventilation Shall Be Attractive Punched Pattern For Ventilation . 10 10 Supplying And Placing Wall Storage Of Following Specifications Overall Dimensions Of Wall Storage 900 W Shall Be 900 Mmw X 328Mm D X 785 Mmh . The Construction Shall Be Aesthetically Appealing Completely Knock Down Construction Made From 0.6 Mm Thk. Crca As Per Is - 513 . Horizontal Stiffener Shall Be Made From 1.2 Mm Thk. Crca As Per Is - 513 . The Doors Shall Be Madefrom 18 Mm Thk. Interior Grade Pre-Laminated Board As Per Is - 12823 Or 18 Mm Thk . Plain Particle Board As Per Is -3087 With 0.6 Thk. With 0.6 Mmthk. Decorative Laminate And 0.6 Mm Thk. Backing Laminate As Per Is - 2046 On Either Side . All Edges Shall Be Duly Sealed With 2 Mm Thk. Pvc Edge Banding . Twodoor Withsingle Lockon Rhdoor . Locking Shall Be 10 Lever Cam Lock Lever At The Bottom Of The Door .Shelving Shall Be Heightwise Adjustable Shelf 1 No. Uniformly Distributed Load Capacity Of 25 Kg Udl .The Finish Shall Be Epoxy Powder Coated To The Thickness Of 50 Microns . The Doors Shall Be 448 Mm W X 18 Mm D X 783 Mm H Rh Side Door With Lock. 448 Mm W X 18 Mm D X 783 Mm H Lh Side Door W / Olock . The Doors Shall Be Madefrom 18 Mm Thk. Interior Grade Pre-Laminated Board As Per Is - 12823 Or 18 Mm Thk . Plain Particle Board As Per Is -3087 With 0.6 Thk. With 0.6 Mmthk. Decorative Laminate And 0.6 Mm Thk. Backing Laminate As Per Is - 2046 On Either Side . All Edges Shall Be Duly Sealed With 2 Mm Thk. Pvc Edge Banding .It Shall Have Two Door With Single Lock On Rh Door 11 11 Providing And Fixing Manual Chain Operated Roller Blinds Consisting Of 100% Polyester Fabric, Fabric Thickness 0.50 Mm Fabric Weight = 270 Gsm+- 5% , Fabric Width 230Cms, Tearing Strength 4.5 Kgf Warp, Bursting Strength 34 Kgf, Colour Fastness To Light 5 To 6 Grade In Position Of Standard Quantity And Approved Shade / Colour Including Necessary Accessories, Ms Clamps.Screws And Drilling Etc. As Required All Complete As Per Directions Of Engineer-In -Charge. ( Approved Make: Vista / Mac / Sd ) 12 Electrical Worksh-01 ( Wiring And Accessories ) 1 Wiringforlightpoint / Fanpoint / Exhaustfanpoint / Callbellpoint With1.5 Sq.Mmfrls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessedmediumclasspvcconduit, Withmodular Switch, Modularplate, Suitablegiboxandearthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required.A Group C 13 2 Wiringforgroupcontrolled ( Looped ) Lightpoint / Fan Point / Exhaustfan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required.A Group C 14 3 Supply And Fixing Suitable Sizegi Box With Modular Plateand Coverinfrontonsurfaceorinrecess Includingprovidingandfixing6pin, 15 / 16Amps Modular Socket Outlet And 15 / 16 Amps Modular Switch , Connection Etc . As Required . 15 4 Wiring For Light / Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessedmediumclasspvcconduitalong With1no.4Sq.Mmfrlspvcinsulatedcopper Conductor Single Core Cable For Loop Earthing As Required. 16 5 Wiring For Light / Power Plug With 4X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessedmediumclasspvcconduit Alongwith2nos.4Sq.Mmfrlspvcinsulated Copper Conductor Singlecorecablefor Loopearthing As Required. 17 6 Wiringforcircuit / Submainwiringalongwithearth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit Asrequired.A ) 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 18 B ) 2 X 10 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 19 7 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable Inthe Existing Surface / Recessedsteelconduitasrequired A ) 3 X 2.5 Sq. Mm 20 B ) 3 X 4 Sqmm 21 C ) 6 X 4 Sq. Mm 22 8 Supplying And Fixing Modular Blanking Plate , On The Existing Modular Plate & Switch Box Excluding Modular Plate Etc. As Required. 23 9 Supplying And Fixing Following Modular Switch / Socketontheexistingmodularplate&Switchbox Including Connectionsbutexcludingmodularplate Etc. As Required.A 5 / 6 A Switch 24 B 3 Pin 5 / 6 A Socket Outlet 25 10 Supplying And Fixing Following Modular Base & Coverplateonexistingmodularmetalboxesetc.As Required.A 3 Module 26 B 6 Module 27 11 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required.A 12 Module ( 200Mmx150mm ) 28 Sh-02 ( Distribution Board ) 12 Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 Volts, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted.A ) 6 Way ( 4 + 18 ) , Double Door 29 13 Supplyingandfixing5ampsto32amps, Rating, 240 / 415Volts, CCurve, Miniaturecircuitbreaker Suitableforinductiveloadoffollowingpolesinthe Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.A ) Single Pole 30 14 Supplying And Fixing Folowingrating Double Pole 240 Volts, Mcbin The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.A ) 63 Amp Doublepole Mcb 31 15 Supplyingandfixingfollowingratingdoublepole 240Volts, Residual Current Circuit Breaker ( Rccb ) , Having Sensitivity Of 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.A ) 63 Amp Dp Rccb 32 16 Supplying And Fixing 63 Amps Rating, 240 / 415 Volts, 10 Ka, “C” Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.A Single Pole 33 17Supplying And Fixing Tpn Mcb 63 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required 34 Sh-03 Light / Fan Fixtures ) 18 Dismantling The Existing Worn Out / Defective Fittings From The Ceiling Andsitc Of Minimum 36 Watt Aluminium Slim Energy Efficient Led Panel Light Fitting Made Of Crca Sheet, Steel Housing Duly Powder Coatedhaving System Efficacy Minimum 100 Lumen / Watt Lm79, Color Temp 6500 Deg K, Symmetric Glare Free Full Opal Diffuser, Ip 20 Illumination In The False Ceiling, Recess Mounting Suitable For Fitting In The 600Mm X 600Mm Square Existing Space Having Complete With All Standard Accessories Including Drivers Etc. Complete As Required. 35 19 Sitc Of Minimum 20 Watt Aluminium Slim Energy Efficient Led Panel Light Fitting Made Of Crca Sheet, Steel Housing Duly Powder Coatedhaving System Efficacy Minimum 100 Lumen / Watt Lm79, Color Temp 6500 Deg K, Symmetric Glare Free Full Opal Diffuser, Ip 20 Illumination In The False Ceiling, Suspended Mounting Suitable For Fitting In The Existing Space Having Complete With All Standard Accessories Including Drivers Etc. Complete As Required. 36 20 Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cmm / W ) Minimum 6.85, Air Delivery Minimum 215 Cmm, 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. 37 Sh-04 ( Earthing ) 21 Earthing With Copper Earth Plate 600Mm X 600Mm X 3Mm Thick Including Accessories And Providing Masonryenclosurewithcoverplatehavinglocking Arrangementandwateringpipeof2.7Mtrlongetc With Charcoal, Coke And Salt As Required. ( For Computer Earthing ) 38 22 Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. 39 23 Providing And Fixing 25 Mm X 5 Mm Copper Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With Brass Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. 40 Sh - 05 ( Networking ) 24 Supplying And Drawing Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 1 Run Of Cable ( Make:- Commscope Systimax Only ) 41 25 Providing And Fixing 24 Port Loaded Straight Patch Panel Of Height 1U In The Existing Data End Rack Including Making Connections, Channel Labellingetc. Complete As Required. 42 26 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.A Rj 45 Information Outlet 43 27 Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal Boxes Etc. As Required.A 1 Or 2 Module 44 28 Providing And Fixing Stranded Low Smoke Halogen Cordage Unshielded Cat 6 Modular Patch Cord Of Length 1 Mtr With Plug Insertion Life Not Less Than 750 Times And Minimum Plug Retention Force Of 133N I / C Making Connections Etc. Complete As Required. 45 29 Providing And Fixing Stranded Low Smoke Halogen Cordage Unshielded Cat 6 Modular Patch Cord Of Length 2 Mtr With Plug Insertion Life Not Less Than 750 Times And Minimum Plug Retention Force Of 133N I / C Making Connections Etc. Complete As Required. 46 30 Sitc Of12u Floor Mount Network Rack With Accessories ( Make:- Rittal / Apw / Emerson ) 47 31 Sitc Of 24 Port Non-Poe Managed Access Switchs Per Specifications In Annexure -A As Per Directions Of Engineer In-Charge 48 32 5 Years 24X7 Onsite Comprehensive Warranty And Support For24 Port Non-Poe Managedaccess Switch As Per Specifications Provided And Installed Under This Contract As Required. A ) For 1St Year 49 B ) For 2Nd Year 50 C ) For 3Rd Year 51 D ) For 4Th Year 52 E ) For 5Th Year 53 33 Suppling And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Inculding Cutting The Wall And Making Good The Same In Case Of Recessed Condit As Required.25Mm Pvc Conduit 54 34 Supplying And Fixing Of Upvc Trunking Of Size 100 X 50 Along With Accessories On Surface Complete As Required. 55 35 Dismantling & Buy Back Of Old & Defective Following Items As Per Required. A 4 X 1 Light Fitting. 56 B Ceiling Fans
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
21.
Power #10421753 Price Bid
Tender For Renovation Of C/R building, Development Of Yard,Raising Road Level And Other Miscellaneous Civil Works At 33 Kv S/S Rajgarh - 1 PART-A 2 (B-162/14.55)Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. 3 1.8E/W in excavation by mechanical means (hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5m in whichor 10 sqm on plan) including dressingof sidesand ramming of bottoms, lift up to 1.5 m, including taking outthe excavated soil and depositing and refilling of jhiri with watering &ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils. 4 (B-54/3.1.6)Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) 5 (B) M15 grade Nominal Mix1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size). (3.1.2) 6 RR stone masonry for with hard stone in foundation and plinth in CSM above 30cm thick wall in CM 1:6 (1cement :6 Sand) (6.1.6) 7 (B-107/10.16)Stone slab roofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both sides in cement sand mortar 1:4,with ceiling pointing in cement sand mortar 1 : 3 complete as per specification and instruction of Engineer In Charge 8 (B-72/6.15)Providing and fixing horizontal chajja of Red/ White sand stone 40 mm thick and upto 80 cm projection in cement mortar 1:4 (1 cement : 4 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 9 (B-65/5.2.2)Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) 10 (B-66/5.8.3)Half brick masonry in Superstructure , above plinth level upto floor Vlevelusing bricks of designation 75 Cement mortar 1 : 6 (1 cement : 6 coarse sand) 11 (B-139/12.3.2)Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish:20mm thick. 12 (B-139/12.5)6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) 13 (B-139/12.3.1)25 mm thick 14 (B-144/12.37.3)Removing dry or oil bound distemper by scrapping sand papering and preparing surface smooth including necessary repairs to scratches by sandla/loi and all scaffolding (for colour changing only) 15 (B-142/12.22.1)Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete.(A) New Plastered Surface (three or more coats) 16 (B-144/12.37.1)Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:New work (two or more coats) over and including scrapping andpriming coat with cement primer. 17 (B-145/12.42)Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). 18 (B-146/12.46.1)Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :(A) Two or more coats on new work 19 (B-146/12.46.2)(B) One or more coats on old work. 20 (B-15.29)Providing and Applying ACRYLIC emulsion polymer waterproofing chemical coating, on over roof on over roofslabs/terrace/balconies/parapet wall etc.with following method/specification:Paint the surface with regular paint brush so as to obtain approximately 0.3mm thickness coating. apply the 2nd coat next day at right angles to the 1st coat so that total thickness of the coating should be approximately 0.6mm coverage by using above formulation will be 40 ft2/ litre of chemical. painted surface does not require any external water curing since chemical will hold sufficient water for curing.After the primer coat Apply 2 coats of modified acrylic emulsion polymer water proofing compound having solar heat reduction properties coating @ 0.330 KG/SQM on the surface of the interval of 3-4 hours. Undulation on the surface is repair before the waterproofing work. 21 (B-109/10.22)Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 22 (B-56/3.8)Providing&fixingprecastcementconcretecoping1:2:4mix50mmthickcompleteas per specification : 23 (B-101/9.19.3)Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :Windows side hung /Ventilators top or centre hung (openable) 24 (B-102/9.26)Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. 25 (B-102/9.27)Providing and fixing Square bars or other flat welded to window, ventilatiors etc. 26 (B-133/11.26)Random rubble dry stone Kharanja under floor. 27 (B-98/9.5)Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 28 (B-72/6.17.3)Supplying and fixing in walls machine cut and polished stone shelves, tands andin CM 1:3 with machine cut edges :Kota stone minimum 30mm thick. 29 (B-100/9.17)Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint 30 (B-93/8.13.2.1)Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A: 30 mm thick .Commercial Veneer both side 31 (B-93/8.14)Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. 32 (B-146/12.45.1)Applying priming coat :With ready mix pink or gray primer of approved brand and manufacture on wood work hard and soft wood. 33 (B-72/6.18.1)Supplying and fixing stone lintels/bed plates of approvedquarryroughdressedincement mortar 1:4 :Upto 15 cm. thick. 34 (B-152/13.24)Labour charges for repair to door / window with out using any material such as applying randha ( finishing ) tightening of bolts & screw etc 35 (B-150/13.4.1)Renewing glass panes,with putty and nails wherever necessary Float glass panes of thickness 4 mm 36 9.8Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. 37 9.8.1(A) Extra if square,rectangular hollow tubelarsections are used or grill made by flats only 38 9.2Structural steel work riveted,bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: 39 (B-104/9.38.3)Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size.Welded mesh 25 mmx 25 mm x 2.1 mm 40 7.25.1P & F 1st quality Heavy Duty Vitrified Double Charged tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete.size600 mm X 600mm 41 10.33.2Providing & fixing calcium silicate perforated ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-Charge of thickness of tiles as mentioned below:-8 mm thick 42 (B-/9.39)P & F of double leaf steel shutter for cupboard, the frame is made of pressed steel ISI section 80X25 mm X 1.25mm thick with 1.00mm MS sheet to spot welded including holdfasts of 15X3mm, MS oxidized fittings such as butt hinges, sliding doors bolts, handles, tower bolts & twin peg etc complete including applying priming coat of approved steel primer of red oxide zinc chromate & spray painting in approved shade with deco paint of approved quality complete as per direction of Engineer in charge. 43 (B- /8.33)Providing and fixing Almirah lock (50 to 70 mm size )of approved makewithout pair of handles for door with necessary screws etc completeas per direction of Engineer-in-charge. 44 (B- /13.12)Repair to stone masonary in cement sand mortar 1:6 with old and new stone. 45 B-/16.58)Supplying and fixing Rollor Blinds of good quality and approved make made out of Imported fabric including Roller Mechanism and lock with chain system with all necessary hooks etc. complete as per direction and sample approved by engineer-in-charge. 46 13.29/B-153Repair to damaged RCC slabs, beams and columns etc for strengthening with cement mortar 1 : 2 in following steps :- i) Choping losse and cracked concrete to required depth, cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary and getting dried..ii) Applying Epoxy primer on the exposed steel bars. iii) Applying Epoxy hardener and resin mix (as per manufectureds specification) on concrete and steel bars with brush.iv) Speading dry cement mortar 1 : 2 mix over epoxy treated wet surface and allow it to dry for one day.v) Plastering the surface with cement sand mortar 1 : 3 upto depth of 30mm complete.(vi) Cure the plastered surface for 15 days, All work including scaffolding etc. complete in all respect. 47 3.28Emptying of Septic tank ,Soakage well etc. by disposing or sludge upto 5 Km. lead & taking out sewage including cleaning of site. 48 (B-86/7.12)Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 49 (B-86/7.13)Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 50 (S-218/1.20.3)P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall:PVC withPVCbend and superior internal fittings as per IS : 7231 . 51 (S-220/1.59)P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. 52 (S-/1.65)P & F C.P. Health Faucet with 1Mtr. Long Tube & Hook of approved make and heavy as per direction of Enginner-in-Charge 53 (S-/2.33.5)Providing and fixingSuperior quality CP Brassfittings of approved make as per direction of Engineer-in-charge Two way Bib Cock 15 mm nominal size 54 (S-231/2.6.5)P & F Pilllar Cocks (IS :8931 : 1993 Mark) of superior quality and approved make:C.P. Pillar cock, high-neck, 15 mm nominal bore. 55 (S-223/1.43.1)P& F waste Pipe with all fitting P.V.C with C.Pnut 32 mm 56 (S-218/1.14.1)P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete.Flat Back (small) size 456x355x265mm. . 57 (S-223/1.45.1)P & F Looking Mirrors with P.V.C. frame of approved make as per direction of Engineer-in-charge Size 500x400mm 58 (S-221/1.36.3)P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall :Size 550 mm x 400 mm 59 (S-224/1.47.8)P & F Towel Rail or Ring of approved quality/make: C.P. Brass Towel Ring revolving type 60 (S-225/1.52.1)P & F Soap Dish or Tray of approved quality / make C.P. brass 61 (S-240/2.38.2)Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)(A) 20mm nominal size 62 (S-240/2.38.4)(B) 32mm nominal size 63 (S-240/2.39.2)Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge. (External work).(A) 20 mm nominal size 64 (S-240/2.39.4)(B) 32 mm nominal size 65 (S-233/2.12.1)P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. Inlet connection 15mm.Brass (IS : 8931 marked) 66 (S-232/2.7.3)P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make:C.P. Brass bib cock,15mm nominal bore. 67 (S-233/2.14.9)P & F Flush Cock / Flush Valve (IS : 9758 Mark) for WC of approved quality make :Brass / GunmetalHalf-turnwt. 1 Kg.ofapprovedquality / make,25mmnominalbore. 68 (S-233/2.15.1)P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make:Gun metal 15 mm nominal bore 69 (S-233/2.15.3)Gun metal 25 mm nominal bore 70 (S-233/2.13.7)P & F 15 mm. Dia Connection Pipe of approved quality/make :CP Brass Pipe with CP Brass nuts upto length 450mm. 71 (S-236/2.26.3)P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 500 litres capacity. 72 (S-232/2.11.2)P & F Ball Cock (IS :1703 Mark) with Rod & P.V.C. Ballcomplete :Brass wt. Not less than 400 gm, 20mm. 73 (S-247/3.16.2)P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2 approved quality /make including joining the pipe with solvent cement rubber ring and lubricant.(b)75 mm dia 74 (S-247/3.16.3)(b)110 mm dia 75 (S-244/3.3.1)Providing & Laying C.C. 1:5:10 (Stone aggregate 40mm nominal size) upto haunches of S.W. pipes including 150 mm thick bed concrete (Width W= Dia of pipe in Cm+ 30Cm.) concrete width to be reduced from width W at center of pipe to `0` at top of pipe. (Excluding cost of pipe)100mm dia S.W. pipe 76 (S-248/3.17.9.(ii))P&F rigid PVC pipe fittings (IS: 4985 mark) of approvedquality /make including joining the pipe with solvent cement rubber ring and lubricant:Bend 87.5-110 mm dia 77 (S-249/3.17.12(ii))Vent Cowel 110 mm dia 78 (S-248/3.17.3(ii))Plain Tee110 mm dia 79 (S-249/3.17.15(ii))Pipe Clip 110 mm dia 80 (S-251/3.21.2)Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m,10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr.Inside size 450 x 450mm depth upto 0.5 M Cement cover with frame 81 (S-255/3.38.1)Construction of Cement Concrete Chamber 125mm dia.C.P. Brass grating 82 (E-07/3.1.1)Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked ( IS:14927 P - II ) virgin materialUPVC trunking & its accessories, Hot Dipped GalvanizedModular box of 1.2 mm thickwith earth terminal/ Surface Moulded virgin materialUPVCModular Box , 10 A Modular switch,Modular faceplate with grid plate, 3 pin ceiling rose/holder /3 way Connector,screws,making connections, testing etc. as required. For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR Short point (up to 3 mtr.) 83 (E-07/3.1.2)Medium point (up to 6 mtr.) 84 (E-07/3.1.3)Long point(up to 10 mtr..) 85 (E-08/3.3.1)Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) on surfaceISI marked ( IS:14927 P - II ) virgin materialUPVC Trunking & its accessories, Hot Dipped GalvanizedModular box of 1.2 mm thickwith earth terminal/ Surface Moulded virgin materialUPVCModular Box,modular 10A switch, 3/5 pin6 Amodular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR:On board 86 (E-9/4.1.7)Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 2 x 2.5 sq. mm. + 1x1.5sqmm 87 (E-9/4.1.14)2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 88 (E-8/3.4.2)S&F following sizesof ISI marked ( IS:14927 P - II ) virgin materialUPVC trunking along with accessorieslike coupler, inner, outer, elbow, square box, tee, end cap etc. on surfacewithscrews, expansionfastenersas required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 mm x 12 mm 89 (E-33/7.36)Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works withGalvanized box of 1.2 mm thickwith earth terminal with suitable size phenolic laminated sheet (IS : 2036 -1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outletmaking connection , testing , etc. as required. . For specification ofWiring accessories refer ChapterE - 07 related item &For additional technical parameters of product / work refer Annexure A attached with this BSR 90 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Single pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating(E-17/6.1.1.2) 91 Providing & Fixing of 240/415 V isolatorISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage,true contact indication,Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm.IP 20 contact protection and fitted in existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR Double pole isolator 63 A Rating (E-18/6.2.1.2) 92 (E-22/6.10.1.2)Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Metaldoor (single phase) IK-09 and IP-43 with Metal end box 6 way(6+2) 93 (E-30/7.26)Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 (E-30/7.21)Providing & Fixing of IS 11037:1984markednon modular socket size flush type 180 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 95 (E-81/15.7.3)Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) 96 (E-88/17.4.2.2) Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Surface Moutning Minimum lumen output 3600 lm 97 (E-82/15.15.1)Providing & Fixing of 450 mm SweepOscillating type Wall mounting / Pedestal typefans with Three speed, ON andOFF position, Sintered Iron bush oil impregnated,with metal front and back 120 or moreribs guard; Three no. Aluminiumblades, minimum Air delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum./min/watt, noise level should be <= 75 dB, power consumption <= 120 watts, motor protection through thermal overload protection device, including fixing with anchor bolts, making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Wall mounting type with Adjustable Vertical Angle 98 (E-95/18.12.6)Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .LLED Street Light fixture with Minimum lumen output 11225 lm 99 (E-95/18.12.2)LED Street Light fixture with Minimum lumen output 3700 lm 100 (E-96/18.18.3)PProviding & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 32 mm Dia. 101 P & F IS:371 marked6 amp surface type ceiling rose including making connection testing etc. as required.Group2E071400Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .(E-28/7.12) 102 P & F ISI marked6 amp bakelite batten/angle holder including making connection testing etc. as required.Group2Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .(E-28/7.13) 103 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing (E-87/17.2.2) 104 (E-56/11.2.1.1)Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 4.0sqmm 2core. 105 (E-90/17.9.3)Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulbin existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI >70,minimum life time of minimum25000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure A attacheded with this BSR. 9 Watt 106 (E-82/15.12.1)Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .300 mm sweep(900/1400 RPM) 107 11.38.3(A)Providing and laying ofpaver block as per IS 15658 : 2006 (Indian standard for precast concrete block for paving- specification) and IRC : SP:63-2004 (guidelines for the use of interlocking concrete block pavement)M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 0.5 to 2.0 MSA for a design life of 20 years.) like city streets, small and medium market roads, low volume roads, utility cuts on arterial roads, etc.Category A Denated units to key into each other on four faces zigzagshape as per IRC SP 63:2004 108 11.39Add extra over item No. 11.38, A to C if reflective paver block, manufactured with wet cast vibration system in two layers is used. 109 11.40Add extra over rates of item No. 11.38, A to C if colored paver blocks are used 110 7.52Providing and fixing machine pressed cement concrete (M-20) compressed with hydraulic compression machine kerbs or dands of size upto 60cm length as per drawing, jointing with cement mortar (1:3) over 20 mm thick base cement mortar (1:6) & painting the exposed surface with enamel paint of approved brand complete work as per direction of Engineer in charge size 15 cm x 38 cm. 111 17.1Supply and installation of Multi Rib Proofing/cladding Sheet Manufacture out of0.50mm TCT (Total Coated Thickness) high tensile Zinc aluminum alloy coated galvalume steel (as per 150gsm zinc aluminum coated 550Mpa tuekd strength) confirming to IS: 1397/astm A-792 sheet to have wide pens 30mm high NB at 250 centre and centre width of 1020mm sheets be casted with regular modified polyster system on a continuous with line on centre for face and with a polyster coating respectively sheet shall have proportionality with siphoned plate made to prevent leakage sheet shall be fixed by more of sell drilling lift tapping hot dip zinc coated hox head fasterner of size 12x14x55mm long. The sheet shall be supplied in cost one length and for a minimum up to 12mts with all scaffolding. 112 9.3.1Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.Hot finished welded type tubes. 113 (B-175 /16.1.1.1)Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately).For fixed portion Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) 114 (B-175 /16.1.2.1)Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately).For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately).Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) 115 (16.10.2)Providing and fixing expanded grill made of aluminum as per designand drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, Y and H aluminium sec (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge. Powder coating aluminum ( minimum thickness of powder coating 50micron) 116 (B-176/16.5.2)Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.)With float glass panes of 5.0 mm thickness ( weight not less than 13.50 kg/sqm) 117 (B-176 /16.4.1)Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge.Pre-laminatedparticleboardwithdecorativelaminationononesideandbalancinglaminationonotherside. 118 (B-177/16.8)Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. 119 (B-177/16.9.3)Providing and fixing aluminium U shape handle of size 100mm with SS screws etc. Complete as per direction of Engineer-in-chargePolyester powder coated minimum thickness 50 micron aluminium . 120 (B-176/16.6.1)Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S. With stainless steel cover plate 121 (B-95/8.27)Providing and fixing IS : 3564 marked aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. complete. 122 (R-19/5.3)Providing, laying, spreading and compacting stone aggregate of as per table 400-10 and 400-11 Wet mix macadam specifications including premixing the material with water to OMC in wet mix plant as per approved design mix, carriage of mixed material by tipper to site laying in uniform layers with motor grader/F.E.Loader/Paver finisher, in sub base/base coarse on a well prepared under base and compacting with vibratory roller to achieve the desired density including lighting, guarding, barricading and maintenance of diversion etc. (MoRTH specifications : Clause 406) by mechanical mean with all lead. 123 14.9.2Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge:In cement mortar.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
22.
Power #10421750 Price Bid
Tender For Yard Development Work, Construction Of Ladies Toilet, Construction Of App Road In Campus And Other Misc Civil Works At 33 Kv S/S Campus Dph - 1 PART-A 2 (B-162/14.55)Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. 3 1.8E/W in excavation by mechanical means (hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5m in whichor 10 sqm on plan) including dressingof sidesand ramming of bottoms, lift up to 1.5 m, including taking outthe excavated soil and depositing and refilling of jhiri with watering &ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils. 4 (B-54/3.1.6)Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) 5 (B) M15 grade Nominal Mix1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size). (3.1.2) 6 RR stone masonry for with hard stone in foundation and plinth in CSM above 30cm thick wall in CM 1:6 (1cement :6 Sand) (6.1.6) 7 (B-107/10.16)Stone slab roofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both sides in cement sand mortar 1:4,with ceiling pointing in cement sand mortar 1 : 3 complete as per specification and instruction of Engineer In Charge 8 (B-72/6.15)Providing and fixing horizontal chajja of Red/ White sand stone 40 mm thick and upto 80 cm projection in cement mortar 1:4 (1 cement : 4 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 9 (B-65/5.2.2)Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) 10 (B-66/5.8.3)Half brick masonry in Superstructure , above plinth level upto floor Vlevelusing bricks of designation 75 Cement mortar 1 : 6 (1 cement : 6 coarse sand) 11 (B-139/12.3.2)Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish:20mm thick. 12 (B-139/12.5)6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) 13 (B-139/12.3.3)12 mm thick 14 (B-139/12.3.1)25 mm thick 15 (B-144/12.37.3)Removing dry or oil bound distemper by scrapping sand papering and preparing surface smooth including necessary repairs to scratches by sandla/loi and all scaffolding (for colour changing only) 16 (B-142/12.22.1)Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete.(A) New Plastered Surface (three or more coats) 17 (B-144/12.37.1)Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:New work (two or more coats) over and including scrapping andpriming coat with cement primer. 18 (B-145/12.42)Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). 19 (B-146/12.46.1)Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :(A) Two or more coats on new work 20 (B-146/12.46.2)(B) One or more coats on old work. 21 (B-107/10.17.1)Grading roof for water proofing treatment withwater proffing compoundCement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 22 (B-140/12.7)Finishing with neat cement (punning). 23 (B-109/10.22)Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 24 (B-56/3.8)Providing&fixingprecastcementconcretecoping1:2:4mix50mmthickcompleteas per specification : 25 (B-101/9.19.3)Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :Windows side hung /Ventilators top or centre hung (openable) 26 (B-102/9.26)Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. 27 (B-102/9.27)Providing and fixing Square bars or other flat welded to window, ventilatiors etc. 28 (B-133/11.26)Random rubble dry stone Kharanja under floor. 29 (B-98/9.5)Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 30 (B-72/6.17.3)Supplying and fixing in walls machine cut and polished stone shelves, tands andin CM 1:3 with machine cut edges :Kota stone minimum 30mm thick. 31 (B-100/9.17)Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint 32 (B-93/8.13.2.1)Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A: 30 mm thick .Commercial Veneer both side 33 (B-93/8.14)Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. 34 (B-146/12.45.1)Applying priming coat :With ready mix pink or gray primer of approved brand and manufacture on wood work hard and soft wood. 35 (B-72/6.18.1)Supplying and fixing stone lintels/bed plates of approvedquarryroughdressedincement mortar 1:4 :Upto 15 cm. thick. 36 (B-132/11.19.1)Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. For area of each slab upto 2001 sqcm 37 (B-86/7.12)Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 38 (B-86/7.13)Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 39 (S-217/1.2.2)P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: Size 580x440mm. 40 (S-218/1.14.1)P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete.Flat Back (small) size 456x355x265mm. . 41 (S-223/1.45.1)P & F Looking Mirrors with P.V.C. frame of approved make as per direction of Engineer-in-charge Size 500x400mm 42 (S-221/1.36.3)P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall :Size 550 mm x 400 mm 43 (S-224/1.47.8)P & F Towel Rail or Ring of approved quality/make: C.P. Brass Towel Ring revolving type 44 (S-225/1.52.1)P & F Soap Dish or Tray of approved quality / make C.P. brass 45 (S-240/2.38.2)Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)(A) 20mm nominal size 46 (S-240/2.38.4)(B) 32mm nominal size 47 (S-240/2.39.2)Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge. (External work).(A) 20 mm nominal size 48 (S-240/2.39.4)(B) 32 mm nominal size 49 (S-233/2.12.1)P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. Inlet connection 15mm.Brass (IS : 8931 marked) 50 (S-232/2.7.3)P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make:C.P. Brass bib cock,15mm nominal bore. 51 (S-233/2.14.9)P & F Flush Cock / Flush Valve (IS : 9758 Mark) for WC of approved quality make :Brass / GunmetalHalf-turnwt. 1 Kg.ofapprovedquality / make,25mmnominalbore. 52 (S-233/2.15.1)P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make:Gun metal 15 mm nominal bore 53 (S-233/2.15.3)Gun metal 25 mm nominal bore 54 (S-233/2.13.7)P & F 15 mm. Dia Connection Pipe of approved quality/make :CP Brass Pipe with CP Brass nuts upto length 450mm. 55 (S-236/2.26.3)P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 500 litres capacity. 56 (S-232/2.11.2)P & F Ball Cock (IS :1703 Mark) with Rod & P.V.C. Ballcomplete :Brass wt. Not less than 400 gm, 20mm. 57 (S-250/3.19.1)Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.Depth up to 0.5 M 58 Construction of Soakage well in all types of soil of approved drawing, top 90 Cm .Portion in 450mm thick masonry with CM 1:6, 80 mm thick stone slab covering,jointing of slab in CM 1:3 ,Ralthal, kharanja 40mm thick M-15 grade C.C flooring, earth worketc . complete including disposal of surplus earth within a lead of 50 mtr . Inner dia90 Cm & 10 to 12 Mtr deep. (3.24.1) 59 (S-/4.25.1)Supply & fixing Pre-cast RCC Rinngs at the mouth of recharge shaft of M20 mix with40 mm thicknessDiameter 900 mm 60 (S-247/3.16.2)P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2 approved quality /make including joining the pipe with solvent cement rubber ring and lubricant.(b)75 mm dia 61 (S-247/3.16.3)(b)110 mm dia 62 (S-244/3.3.1)Providing & Laying C.C. 1:5:10 (Stone aggregate 40mm nominal size) upto haunches of S.W. pipes including 150 mm thick bed concrete (Width W= Dia of pipe in Cm+ 30Cm.) concrete width to be reduced from width W at center of pipe to `0` at top of pipe. (Excluding cost of pipe)100mm dia S.W. pipe 63 (S-248/3.17.9.(ii))P&F rigid PVC pipe fittings (IS: 4985 mark) of approvedquality /make including joining the pipe with solvent cement rubber ring and lubricant:Bend 87.5-110 mm dia 64 (S-249/3.17.12(ii))Vent Cowel 110 mm dia 65 (S-248/3.17.3(ii))Plain Tee110 mm dia 66 (S-249/3.17.15(ii))Pipe Clip 110 mm dia 67 (S-251/3.21.2)Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m,10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr.Inside size 450 x 450mm depth upto 0.5 M Cement cover with frame 68 (S-255/3.38.1)Construction of Cement Concrete Chamber 125mm dia.C.P. Brass grating 69 (S-217/1.3)P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor 70 (S-217/1.7.2)P & F water closet Seat Covers with brass hinges complete :Solid PVC (IS 2548 marked) grade-I-do- White. 71 (S-217/1.9)Labour charges for removing W.C. pan (any type) of all sizes with care including all necessary fittings P or S trap. 72 (S-218/1.20.3)P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall:PVC withPVCbend and superior internal fittings as per IS : 7231 . 73 (S-220/1.59)P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. 74 (S-/1.65)P & F C.P. Health Faucet with 1Mtr. Long Tube & Hook of approved make and heavy as per direction of Enginner-in-Charge 75 (S-/2.33.5)Providing and fixingSuperior quality CP Brassfittings of approved make as per direction of Engineer-in-charge Two way Bib Cock 15 mm nominal size 76 (S-231/2.6.5)P & F Pilllar Cocks (IS :8931 : 1993 Mark) of superior quality and approved make:C.P. Pillar cock, high-neck, 15 mm nominal bore. 77 (E-07/3.1.1)Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked ( IS:14927 P - II ) virgin materialUPVC trunking & its accessories, Hot Dipped GalvanizedModular box of 1.2 mm thickwith earth terminal/ Surface Moulded virgin materialUPVCModular Box , 10 A Modular switch,Modular faceplate with grid plate, 3 pin ceiling rose/holder /3 way Connector,screws,making connections, testing etc. as required. For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR Short point (up to 3 mtr.) 78 (E-07/3.1.2)Medium point (up to 6 mtr.) 79 (E-07/3.1.3)Long point(up to 10 mtr..) 80 (E-08/3.3.1)Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) on surfaceISI marked ( IS:14927 P - II ) virgin materialUPVC Trunking & its accessories, Hot Dipped GalvanizedModular box of 1.2 mm thickwith earth terminal/ Surface Moulded virgin materialUPVCModular Box,modular 10A switch, 3/5 pin6 Amodular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR:On board 81 (E-9/4.1.7)Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 2 x 2.5 sq. mm. + 1x1.5sqmm 82 (E-9/4.1.14)2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 83 (E-8/3.4.2)S&F following sizesof ISI marked ( IS:14927 P - II ) virgin materialUPVC trunking along with accessorieslike coupler, inner, outer, elbow, square box, tee, end cap etc. on surfacewithscrews, expansionfastenersas required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 mm x 12 mm 84 (E-33/7.36)Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works withGalvanized box of 1.2 mm thickwith earth terminal with suitable size phenolic laminated sheet (IS : 2036 -1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outletmaking connection , testing , etc. as required. . For specification ofWiring accessories refer ChapterE - 07 related item &For additional technical parameters of product / work refer Annexure A attached with this BSR 85 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Single pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating(E-17/6.1.1.2) 86 Providing & Fixing of 240/415 V isolatorISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage,true contact indication,Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm.IP 20 contact protection and fitted in existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR Double pole isolator 63 A Rating (E-18/6.2.1.2) 87 (E-22/6.10.1.2)Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Metaldoor (single phase) IK-09 and IP-43 with Metal end box 6 way(6+2) 88 (E-22/6.10.1.1)4 way(4+2) 89 (E-14/5.2.1)P & F in position frame made out of M.S. angle (riveted or welded) finished with two coats of red oxide and two coats enamel paint including cutting, welding, holes etc.of following sizes as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 25mm x 25mm x 3mm 90 (E-14/5.5.3)P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 6.4mm thick 91 P & F IS:371 marked6 amp surface type ceiling rose including making connection testing etc. as required.Group2E071400Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .(E-28/7.12) 92 P & F ISI marked6 amp bakelite batten/angle holder including making connection testing etc. as required.Group2Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .(E-28/7.13) 93 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing (E-87/17.2.2) 94 (E-56/11.2.1.1)Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 4.0sqmm 2core. 95 (E-90/17.9.3)Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulbin existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI >70,minimum life time of minimum25000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure A attacheded with this BSR. 9 Watt 96 (E-82/15.12.1)Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .300 mm sweep(900/1400 RPM) 97 (E-30/7.26)Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 (E-31/7.29.1)Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR5 step fan regulator 2 Module 360 dgree rotating 99 (E-81/15.7.3)Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) 100 (E-88/17.4.2.2) Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Surface Moutning Minimum lumen output 3600 lm 101 (E-82/15.15.1)Providing & Fixing of 450 mm SweepOscillating type Wall mounting / Pedestal typefans with Three speed, ON andOFF position, Sintered Iron bush oil impregnated,with metal front and back 120 or moreribs guard; Three no. Aluminiumblades, minimum Air delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum./min/watt, noise level should be <= 75 dB, power consumption <= 120 watts, motor protection through thermal overload protection device, including fixing with anchor bolts, making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Wall mounting type with Adjustable Vertical Angle 102 (E-95/18.12.6)Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .LLED Street Light fixture with Minimum lumen output 11225 lm 103 (E-95/18.12.2)LED Street Light fixture with Minimum lumen output 3700 lm 104 (E-96/18.18.3)PProviding & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 32 mm Dia. (E-96/18.18.3) 105 (B-175 /16.1.1.1)Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately).For fixed portion Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) 106 (B-175 /16.1.2.1)Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately).For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately).Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) 107 (16.10.2)Providing and fixing expanded grill made of aluminum as per designand drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, Y and H aluminium sec (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge. Powder coating aluminum ( minimum thickness of powder coating 50micron) 108 (B-176/16.5.2)Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.)With float glass panes of 5.0 mm thickness ( weight not less than 13.50 kg/sqm) 109 (B-176 /16.4.1)Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge.Pre-laminatedparticleboardwithdecorativelaminationononesideandbalancinglaminationonotherside. 110 (B-177/16.8)Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. 111 (B-177/16.9.3)Providing and fixing aluminium U shape handle of size 100mm with SS screws etc. Complete as per direction of Engineer-in-chargePolyester powder coated minimum thickness 50 micron aluminium . 112 (B-176/16.6.1)Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S. With stainless steel cover plate 113 (B-95/8.27)Providing and fixing IS : 3564 marked aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. complete. 114 (B-15.29)Providing and Applying ACRYLIC emulsion polymer waterproofing chemical coating, on over roof on over roofslabs/terrace/balconies/parapet wall etc.with following method/specification:Paint the surface with regular paint brush so as to obtain approximately 0.3mm thickness coating. apply the 2nd coat next day at right angles to the 1st coat so that total thickness of the coating should be approximately 0.6mm coverage by using above formulation will be 40 ft2/ litre of chemical. painted surface does not require any external water curing since chemical will hold sufficient water for curing.After the primer coat Apply 2 coats of modified acrylic emulsion polymer water proofing compound having solar heat reduction properties coating @ 0.330 KG/SQM on the surface of the interval of 3-4 hours. Undulation on the surface is repair before the waterproofing work. 115 B-1.31Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 116 (B-152/13.24)Labour charges for repair to door / window with out using any material such as applying randha ( finishing ) tightening of bolts & screw etc 117 (B-150/13.4.1)Renewing glass panes,with putty and nails wherever necessary Float glass panes of thickness 4 mm 118 9.8Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. 119 9.8.1(A) Extra if square,rectangular hollow tubelarsections are used or grill made by flats only 120 9.2Structural steel work riveted,bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: 121 9.3.1Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.Hot finished welded type tubes. 122 17.1Supply and installation of Multi Rib Proofing/cladding Sheet Manufacture out of0.50mm TCT (Total Coated Thickness) high tensile Zinc aluminum alloy coated galvalume steel (as per 150gsm zinc aluminum coated 550Mpa tuekd strength) confirming to IS: 1397/astm A-792 sheet to have wide pens 30mm high NB at 250 centre and centre width of 1020mm sheets be casted with regular modified polyster system on a continuous with line on centre for face and with a polyster coating respectively sheet shall have proportionality with siphoned plate made to prevent leakage sheet shall be fixed by more of sell drilling lift tapping hot dip zinc coated hox head fasterner of size 12x14x55mm long. The sheet shall be supplied in cost one length and for a minimum up to 12mts with all scaffolding. 123 4.9Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 124 (B-/9.39)P & F of double leaf steel shutter for cupboard, the frame is made of pressed steel ISI section 80X25 mm X 1.25mm thick with 1.00mm MS sheet to spot welded including holdfasts of 15X3mm, MS oxidized fittings such as butt hinges, sliding doors bolts, handles, tower bolts & twin peg etc complete including applying priming coat of approved steel primer of red oxide zinc chromate & spray painting in approved shade with deco paint of approved quality complete as per direction of Engineer in charge. 125 (B- /8.33)Providing and fixing Almirah lock (50 to 70 mm size )of approved makewithout pair of handles for door with necessary screws etc completeas per direction of Engineer-in-charge. 126 16.61/B-16 Labour Charges for removing and refixing Aluminium Partitions door including minor repair on alterationin the same. 127 (B- /13.12)Repair to stone masonary in cement sand mortar 1:6 with old and new stone. 128 B-/16.58)Supplying and fixing Rollor Blinds of good quality and approved make made out of Imported fabric including Roller Mechanism and lock with chain system with all necessary hooks etc. complete as per direction and sample approved by engineer-in-charge. 129 (B-156/14.2.2)Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge.1: 4: 8 or leaner mix. 130 (B-48/1.28) Surface dressing of the ground including removing vegetation and inequalities not exceeding 15cm deep and disposal of rubbish lead up to 50 Mtr. and lift up to 1.5 Mtr.: All kinds of soil 131 11.38.3(A)Providing and laying ofpaver block as per IS 15658 : 2006 (Indian standard for precast concrete block for paving- specification) and IRC : SP:63-2004 (guidelines for the use of interlocking concrete block pavement)M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 0.5 to 2.0 MSA for a design life of 20 years.) like city streets, small and medium market roads, low volume roads, utility cuts on arterial roads, etc.Category A Denated units to key into each other on four faces zigzagshape as per IRC SP 63:2004 132 11.39Add extra over item No. 11.38, A to C if reflective paver block, manufactured with wet cast vibration system in two layers is used. 133 (B-/11.40)Add extra over rates of item No. 11.38, A to C if colored paver blocks are used 134 7.52Providing and fixing machine pressed cement concrete (M-20) compressed with hydraulic compression machine kerbs or dands of size upto 60cm length as per drawing, jointing with cement mortar (1:3) over 20 mm thick base cement mortar (1:6) & painting the exposed surface with enamel paint of approved brand complete work as per direction of Engineer in charge size 15 cm x 38 cm. 135 (B-/12.32) Pointing on stone slab ceiling with cement mortar 1:2 (1 cement : 2 fine sand): Flush/ Ruled pointing 136 11.41(B)Providing and fixing 25 mm thick Non slippery reflective type designer paving tile with metallic hardening using 2 Kg/sq.mtr made out of cement concrete of required grade, sizes of tile upto 300X300 mm Manufactured with wet cast Vibration system in two layers and laid over base of 20 mm thick cement morter1:4 using neat cement slurry in cluding finishing of joints etc. complete.Using M-30 grade cement Concrete 137 (B-131/11.17.4)Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand)Ordinary cement without any pigment. 138 13.29/B-153Repair to damaged RCC slabs, beams and columns etc for strengthening with cement mortar 1 : 2 in following steps :- i) Choping losse and cracked concrete to required depth, cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary and getting dried..ii) Applying Epoxy primer on the exposed steel bars. iii) Applying Epoxy hardener and resin mix (as per manufectureds specification) on concrete and steel bars with brush.iv) Speading dry cement mortar 1 : 2 mix over epoxy treated wet surface and allow it to dry for one day.v) Plastering the surface with cement sand mortar 1 : 3 upto depth of 30mm complete.(vi) Cure the plastered surface for 15 days, All work including scaffolding etc. complete in all respect. 139 (B-104/9.38.3)Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size.Welded mesh 25 mmx 25 mm x 2.1 mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
23.
Water Resources and Irrigation #10416117 Price Bid
Development Of 03 Nos. Parks By Providing And Fixing Outdoor Exercise Equipments Along Left Bank Of Supplementary Drain At Rd 34100M,Rd33600m, And Rd32420m In Vikaspuri Assembly Constituency Ac 31 Mla Lad Work- 1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil 2 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size 3 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand). 4 Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. 5 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size). 6 Providing and Fixing36mm thick EPDM(EthylenePropyleneDeineMonomer)Rubber Flooring on existing surface in required colour and shape.The EPDM rubber flooring should be laid at site indual colour and pattern as per the direction of theEngineer-in Charge. All complete fixing of equipment in foundation is to be done as per manufacture specification. 7 Supply and fixing ofArihant /Kompon /Landscape /Koochie / Hugo / Grandslam Fitness Make or equivalent as per direction of Engineer in Charge Big Shoulder Axial Machine: The product to match the colours, design, size, contours and aesthetics exactly as per the image attached. All components designed and manufactured to meet with EN 16630 safety standards. The EN 16630 certificates must be issued by a reputed notified International Certifying Body such as IPEMA, TUV, CPSC, or SGS only. The Product uses Teflon resistance bearings. Dedicated fabrication moulds and jigs for retaining the accuracy and repeatability of the production process. Innovative thermal zinc coating allows full and complete coverage. Zinc injection has been salt spray tested to meet ASTM B117 and ISO 9227 (48 hours) standard with a minimum thickness 40-60 micron. DUPONT ALESTA AD Powder coating for architectural use. Made from carboxyl polyester and TGIC for a thickness of 50 to 70 microns. Handles are made of HDPE handles with free rotate Grips. S-Torx anti Vandal fastners are used in which the nuts are all enclosed in Polyamid anti vandal caps. The Dia of the material is of 89mm, Thickness is 3mm, 60/48/38 Connectors, 10/8 mm steel plates and the material is also CNC laser cut. All components designed and manufactured to meet with EN 16630 safety standards. Samples to be produced to the department before supply. 8 Supply and fixing ofArihant /Kompon /Landscape /Koochie / Hugo / Grandslam Fitness Make or equivalent as per direction of Engineer in Charge 2 Person Tai Chi Teflon Resistance Trainer: The product to match the colours, design, size, contours and aesthetics exactly as per the image attached. All components designed and manufactured to meet with EN 16630 safety standards. The EN 16630 certificates must be issued by a reputed notified International Certifying Body such as IPEMA, TUV, CPSC, or SGS only. The Product uses Teflon resistance bearings. Dedicated fabrication moulds and jigs for retaining the accuracy and repeatability of the production process. Innovative thermal zinc coating allows full and complete coverage. Zinc injection has been salt spray tested to meet ASTM B117 and ISO 9227 (48 hours) standard with a minimum thickness 40-60 micron. DUPONT ALESTA AD Powder coating for architectural use. Made from carboxyl polyester and TGIC for a thickness of 50 to 70 microns. Handles are made of HDPE handles with free rotate Grips. S-Torx anti Vandal fastners are used in which the nuts are all enclosed in Polyamid anti Vandal caps. The Dia of the material is of 89mm, Thickness is 3mm, 60/48/38 Connectors, 10/8 mm steel plates and the material is also CNC laser cut. All components designed and manufactured to meet with EN 16630 safety standards. Samples to be produced to the department before supply. 9 Supply and fixing ofArihant /Kompon /Landscape /Koochie / Hugo / Grandslam Fitness Make or equivalent as per direction of Engineer in Charge Resistance Foot Cycle: The product to match the colours, design, size, contours and aesthetics exactly as per the image attached. All components designed and manufactured to meet with EN 16630 safety standards. The EN 16630 certificates must be issued by a reputed notified International Certifying Body such as IPEMA, TUV, CPSC, or SGS only. The Product uses Teflon resistance bearings. Dedicated fabrication moulds and jigs for retaining the accuracy and repeatability of the production process. Innovative thermal zinc coating allows full and complete coverage. Zinc injection has been salt spray tested to meet ASTM B117 and ISO 9227 (48 hours) standard with a minimum thickness 40-60 micron. DUPONT ALESTA AD Powder coating for architectural use. Made from carboxyl polyester and TGIC for a thickness of 50 to 70 microns. Handle is made of HDPE sub-seat handle. Grips. S-Torx anti Vandal fastners are used in which the nuts are all enclosed in Polyamid anti Vandal caps. The Dia of the material is of 89mm, Thickness is 3mm, 60/48/38 Connectors, 10/8 mm steel plates and the material is also CNC laser cut. All components designed and manufactured to meet with EN 16630 safety standards. Samples to be produced to the department before supply. 10 Supply and fixing ofArihant /Kompon /Landscape /Koochie / Hugo / Grandslam Fitness Make or equivalent as per direction of Engineer in Charge Aero Walker: The product to match the colours, design, size, contours and aesthetics exactly as per the image attached. All components designed and manufactured to meet with EN 16630 safety standards. The EN 16630 certificates must be issued by a reputed notified International Certifying Body such as IPEMA, TUV, CPSC, or SGS only. The Product uses Unique resistance and safestop, Stopper mechanism which limits unwanted movement, it has cushioned movement edges and prevents wear from colliding frame parts. Dedicated fabrication moulds and jigs for retaining the accuracy and repeatability of the production process. Innovative thermal zinc coating allows full and complete coverage. Zinc injection has been salt spray tested to meet ASTM B117 and ISO 9227 (48 hours) standard with a minimum thickness 40-60 micron. DUPONT ALESTA AD Powder coating for architectural use. Made from carboxyl polyester and TGIC for a thickness of 50 to 70 microns. Handles are made of 3mm Endu-Rubber handles with aluminum cap locking anti vandal system. S-Torx anti Vandal fastners are used in which the nuts are all enclosed in Polyamid anti Vandal caps.The Dia of the material is of 89mm, Thickness is 3mm, 60/48/38 Connectors, 10/8 mm steel plates and the material is also CNC laser cut. All components designed and manufactured to meet with EN 16630 safety standards. Samples to be produced to the department before supply 11 Supply and fixing ofArihant /Kompon /Landscape /Koochie / Hugo / Grandslam Fitness Make or equivalent as per direction of Engineer in Charge 2 person Air Skier: The product to match the colours, design, size, contours and aesthetics exactly as per the image attached. All components designed and manufactured to meet with EN 16630 safety standards. The EN 16630 certificates must be issued by a reputed notified International Certifying Body such as IPEMA, TUV, CPSC, or SGS only. The Product uses Unique resistance and safestop, Stopper mechanism which limits unwanted movement, it has cushioned movement edges and prevents wear from colliding frame parts. Dedicated fabrication moulds and jigs for retaining the accuracy and repeatability of the production process. Innovative thermal zinc coating allows full and complete coverage. Zinc injection has been salt spray tested to meet ASTM B117 and ISO 9227 (48 hours) standard with a minimum thickness 40-60 micron. DUPONT ALESTA AD Powder coating for architectural use. Made from carboxyl polyester and TGIC for a thickness of 50 to 70 microns. Handles are made of 38mm Metal frame. S-Torx anti Vandal fastners are used in which the nuts are all enclosed in Polyamid anti Vandal caps.The Dia of the material is of 89mm, Thickness is 3mm, 60/48/38 Connectors, 10/8 mm steel plates and the material is also CNC laser cut. All components designed and manufactured to meet with EN 16630 safety standards. Samples to be produced to the department before supply. 12 Supply and fixing ofArihant /Kompon /Landscape /Koochie / Hugo / Grandslam Fitness Make or equivalent as per direction of Engineer in Charge 3 Person Body Twister: The product to match the colours, design, size, contours and aesthetics exactly as per the image attached. All components designed and manufactured to meet with EN 16630 safety standards. The EN 16630 certificates must be issued by a reputed notified International Certifying Body such as IPEMA, TUV, CPSC, or SGS only. The Product uses Unique resistance and safestop, Stopper mechanism which limits unwanted movement, it has cushioned movement edges and prevents wear from colliding frame parts. Dedicated fabrication moulds and jigs for retaining the accuracy and repeatability of the production process. Innovative thermal zinc coating allows full and complete coverage. Zinc injection has been salt spray tested to meet ASTM B117 and ISO 9227 (48 hours) standard with a minimum thickness 40-60 micron. DUPONT ALESTA AD Powder coating for architectural use. Made from carboxyl polyester and TGIC for a thickness of 50 to 70 microns. Handles are made of 38mm Metal frame. S-Torx anti Vandal fastners are used in which the nuts are all enclosed in Polyamid anti Vandal caps.The Dia of the material is of 89mm, Thickness is 3mm, 60/48/38 Connectors, 10/8 mm steel plates and the material is also CNC laser cut. All components designed and manufactured to meet with EN 16630 safety standards. Samples to be produced to the department before supply. 13 Supply and fixing ofArihant /Kompon /Landscape /Koochie / Hugo / Grandslam Fitness Make or equivalent as per direction of Engineer in Charge 3 Person Body Twister: The product to match the colours, design, size, contours and aesthetics exactly as per the image attached. All components designed and manufactured to meet with EN 16630 safety standards. The EN 16630 certificates must be issued by a reputed notified International Certifying Body such as IPEMA, TUV, CPSC, or SGS only. The Product uses Unique resistance and safestop, Stopper mechanism which limits unwanted movement, it has cushioned movement edges and prevents wear from colliding frame parts. Dedicated fabrication moulds and jigs for retaining the accuracy and repeatability of the production process. Innovative thermal zinc coating allows full and complete coverage. Zinc injection has been salt spray tested to meet ASTM B117 and ISO 9227 (48 hours) standard with a minimum thickness 40-60 micron. DUPONT ALESTA AD Powder coating for architectural use. Made from carboxyl polyester and TGIC for a thickness of 50 to 70 microns. Handles are made of 38mm Metal frame. S-Torx anti Vandal fastners are used in which the nuts are all enclosed in Polyamid anti Vandal caps.The Dia of the material is of 89mm, Thickness is 3mm, 60/48/38 Connectors, 10/8 mm steel plates and the material is also CNC laser cut. All components designed and manufactured to meet with EN 16630 safety standards. Samples to be produced to the department before supply. 14 Supply and fixing ofArihant /Kompon /Landscape /Koochie / Hugo / Grandslam Fitness Make or equivalent as per direction of Engineer in ChargeDouble sit-up bench: The product to match the colours, design, size, contours and aesthetics exactly as per the image attached. All components designed and manufactured to meet with EN 16630 safety standards. The EN 16630 certificates must be issued by a reputed notified International Certifying Body such as IPEMA, TUV, CPSC, or SGS only. Dedicated fabrication moulds and jigs for retaining the accuracy and repeatability of the production process. Innovative thermal zinc coating allows full and complete coverage. Zinc injection has been salt spray tested to meet ASTM B117 and ISO 9227 (48 hours) standard with a minimum thickness 40-60 micron. DUPONT ALESTA AD Powder coating for architectural use. Made from carboxyl polyester and TGIC for a thickness of 50 to 70 microns. Handles are made of 38mm Metal frame with 304 Stainless leg color covers. S-Torx anti Vandal fastners are used in which the nuts are all enclosed in Polyamid anti Vandal caps.The Dia of the material is of 89mm, Thickness is 3mm, 60/48/38 Connectors, 10/8 mm steel plates and the material is also CNC laser cut. All components designed and manufactured to meet with EN 16630 safety standards. Samples to be produced to the department before supply. 15 Supply and fixing ofArihant /Kompon /Landscape /Koochie / Hugo / Grandslam Fitness Make or equivalent as per direction of Engineer in Charge Elliptical Cross Trainer: The product to match the colours, design, size, contours and aesthetics exactly as per the image attached. All components designed and manufactured to meet with EN 16630 safety standards. The EN 16630 certificates must be issued by a reputed notified International Certifying Body such as IPEMA, TUV, CPSC, or SGS only. The Product uses Teflon resistance bearings. Dedicated fabrication moulds and jigs for retaining the accuracy and repeatability of the production process. Innovative thermal zinc coating allows full and complete coverage. Zinc injection has been salt spray tested to meet ASTM B117 and ISO 9227 (48 hours) standard with a minimum thickness 40-60 micron. DUPONT ALESTA AD Powder coating for architectural use. Made from carboxyl polyester and TGIC for a thickness of 50 to 70 microns. Handles are made of 3mm Endu-Rubber handles with aluminum cap locking anti vandal system. S-Torx anti Vandal fastners are used in which the nuts are all enclosed in Polyamid anti Vandal caps.The Dia of the material is of 89mm, Thickness is 3mm, 60/48/38 Connectors, 10/8 mm steel plates and the material is also CNC laser cut. All components designed and manufactured to meet with EN 16630 safety standards. Samples to be produced to the department before supply. 16 Supply and fixing ofArihant /Kompon /Landscape /Koochie / Hugo / Grandslam Fitness Make or equivalent as per direction of Engineer in Charge 2 Person Ski Trainer Machine: The product to match the colours, design, size, contours and aesthetics exactly as per the image attached. All components designed and manufactured to meet with EN 16630 safety standards. The EN 16630 certificates must be issued by a reputed notified International Certifying Body such as IPEMA, TUV, CPSC, or SGS only. The Product uses Unique resistance and safestop, Stopper mechanism which limits unwanted movement, it has cushioned movement edges and prevents wear from colliding frame parts. Dedicated fabrication moulds and jigs for retaining the accuracy and repeatability of the production process. Innovative thermal zinc coating allows full and complete coverage. Zinc injection has been salt spray tested to meet ASTM B117 and ISO 9227 (48 hours) standard with a minimum thickness 40-60 micron. DUPONT ALESTA AD Powder coating for architectural use. Made from carboxyl polyester and TGIC for a thickness of 50 to 70 microns. Handles are made of 3mm Endu-Rubber handles with aluminum cap locking anti vandal system. S-Torx anti vandal fastners are used in which the nuts are all enclosed in Polyamid anti Vandal caps.The Dia of the material is of 89mm, Thickness is 3mm, 60/48/38 Connectors, 10/8 mm steel plates and the material is also CNC laser cut. All components designed and manufactured to meet with EN 16630 safety standards. Samples to be produced to the department before supply. 17 Supply and fixing ofArihant /Kompon /Landscape /Koochie / Hugo / Grandslam Fitness Make or equivalent as per direction of Engineer in ChargeDouble Shoulder Press Station: The product to match the colours, design, size, contours and aesthetics exactly as per the image attached. All components designed and manufactured to meet with EN 16630 safety standards. The EN 16630 certificates must be issued by a reputed notified International Certifying Body such as IPEMA, TUV, CPSC, or SGS only. The Product uses ARM (Angular Resistance Module). The Angular Resistance Module system consists of several components, metal housing, pin and rubber bar. Resistance keep changing according to the movement degree. It can be moved with 2 directions. Dedicated fabrication moulds and jigs for retaining the accuracy and repeatability of the production process. Innovative thermal zinc coating allows full and complete coverage. Zinc injection has been salt spray tested to meet ASTM B117 and ISO 9227 (48 hours) standard with a minimum thickness 40-60 micron. DUPONT ALESTA AD Powder coating for architectural use. Made from carboxyl polyester and TGIC for a thickness of 50 to 70 microns. Handles are made of 3mm Endu-Rubber handles with aluminum cap locking anti vandal system. S-Torx anti Vandal fastners are used in which the nuts are all enclosed in Polyamid anti Vandal caps.The Dia of the material is of 89mm, Thickness is 3mm, 60/48/38 Connectors, 10/8 mm steel plates and the material is also CNC laser cut. All components designed and manufactured to meet with EN 16630 safety standards. Samples to be produced to the department before supply. 18 Supply and fixing ofArihant /Kompon /Landscape /Koochie / Hugo / Grandslam Fitness Make or equivalent as per direction of Engineer in Charge Double Chest Press Station: The product to match the colours, design, size, contours and aesthetics exactly as per the image attached. All components designed and manufactured to meet with EN 16630 safety standards. The EN 16630 certificates must be issued by a reputed notified International Certifying Body such as IPEMA, TUV, CPSC, or SGS only. The Product uses ARM (Angular Resistance Module). The Angular Resistance Module system consists of several components, metal housing, pin and rubber bar. Resistance keep changing according to the movement degree. It can be moved with 2 directions. Dedicated fabrication moulds and jigs for retaining the accuracy and repeatability of the production process. Innovative thermal zinc coating allows full and complete coverage. Zinc injection has been salt spray tested to meet ASTM B117 and ISO 9227 (48 hours) standard with a minimum thickness 40-60 micron. DUPONT ALESTA AD Powder coating for architectural use. Made from carboxyl polyester and TGIC for a thickness of 50 to 70 microns. Handles are made of 3mm Endu-Rubber handles with aluminum cap locking anti vandal system. S-Torx anti Vandal fastners are used in which the nuts are all enclosed in Polyamid anti Vandal caps.The Dia of the material is of 89mm, Thickness is 3mm, 60/48/38 Connectors, 10/8 mm steel plates and the material is also CNC laser cut. All components designed and manufactured to meet with EN 16630 safety standards. Samples to be produced to the department before supply. 19 Supply and fixing ofArihant /Kompon /Landscape /Koochie / Hugo / Grandslam Fitness Make or equivalent as per direction of Engineer in Charge 180cm slide. 20 Supply and fixing ofArihant /Kompon /Landscape /Koochie / Hugo / Grandslam Fitness Make or equivalent as per direction of Engineer in Charge Two seater sea saw.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
24.
Power #10410528 Price Bid
Tender For Smp-Nilakkal-Development Of Core Area At Nilakkal (Re-Tender)- 1 1Site DevelopmentClearing and Grubbing Road LandClearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201.(II) By Mechanical Means(A) In area of non-thorny jungle 2 Excavation in Soil with Dozer with lead upto 100 mExcavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections. 3 Compacting Original Ground(ii) Compacting original ground supporting subgradeLoosening of the ground upto a level of 300 mm below the subgrade level, watered, graded andcompacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as perTechnical Specification Clause 303.5.2. 4 Granular sub-base/base/surface course with local materials (Table 400.13) by mix in place method normal. Construction of granular sub-base by providing local material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at once and compacting with smooth wheel roller to achieve the desired density complete as per Clause 401.4 as per Technical Specification Clause 408.(ii)Using Gravel mix soil. 5 Wet Mix MacadamProviding, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406.By Mechanical Means with 1 km lead 6 Turfing with SodsFurnishing and laying of the live sods of perennial turf forming grass on embankment slope, verges or other locations shown on the drawing or as directed by the Engineer including preparation of ground, fetching of sods and watering as per Technical Specification Clause 309. 7 2Retaining Wall and step Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. 8 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 9 3Paving the walk way with Grass Pavers, Krishnasila Granite stone, Buffalo grass etc. Providing and fixing of precast concrete interlocking Grass PaversM 30 grade300x300x120mm size of (Brand : Basant Betonswith modelART LINE or similar) having surface drainage of28.6%,manufactured from fully computerized automatic stationery hydraulic vibratepressed machine and fully computerized automatic batching plant.Interlocking paver block to be fixed on the bed compacted into 75mm thick coarse sand zone III or similar approved specification and filling the joints with the sand of approved type and quality or as specified and as directed by Engineer-in-charge. The rate should include the cost of providing a sand bed and filling the joints with fine sand (Fine sand zone IV OR SIMILAR), compacting and proper embedding /laying of interlocking paver blocks into the sand bedding, layer through vibratory compaction by using Plate Compactor, filling the joints with sand and cutting of paver blocks as per design, finishing and removing extra sand etc. complete as per direction of Engineer-in-Charge. 10 Providing and fixing KRISHNASILA black granite 90x60x5 cm Flamed surface on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge. 11 Providing and fixing 60x30x2 cm Granite stone block ( K WHITE) Flamed surface on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge. 12 Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10 mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge 13 Providing and laying curb stone(12.50x22.50x30cm size)(sadarhally) thick stone slab over 50 mm (average) thick base of sand etc. all complete as specified and as directed by the Engineer in- Charge 14 Grassing with buffalo grass including watering and maintanence of the lawn till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, in rows 5cm apart in both directions. (watering & maintanance till the completion of project work and handing over to client) 15 Providing and laying factory made chamfered edge Cement Concrete paver blocksin footpath, parks, lawns, drive ways or light traffic parking etc, of required strength,thickness & size/ shape, made by table vibratory method using PU mould, laid inrequired colour & pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sand bedding layerthrough vibratory compaction by using plate vibrator, filling the joints with sand andcutting of paver blocks as per required size and pattern, finishing and sweepingextra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. 16 4Annadanapura (1 Nos) Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 17 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 18 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 19 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 20 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers. 21 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work upto plinth level 22 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 23 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 24 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 25 Supplying and fixing truncated square natural stone pillar of 2.5mtr height, 28cm base width,20cm top width, 30cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain) /manual) etc. complete. 26 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes 27 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work 28 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 29 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). 30 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 31 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 32 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 33 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications: Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm 34 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 35 Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick 36 5 Resting Pavilion -Type 1 (4 Nos)Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 37 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 38 Random rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand) 39 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 40 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers 41 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work upto plinth level 42 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 43 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 44 Supplying and fixing truncated square natural stone pillar of 2.5mtr height, 28cm base width,20cm top width, 30cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain)/manual) etc. complete. 45 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes 46 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work 47 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 48 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). 49 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 50 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 51 12 mm cement plaster of mix:1:4 (1 cement : 4 fine sand) 52 Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick 53 6Water kiosk - (2 Nos) Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 54 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 55 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand) 56 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 57 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers 58 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work upto plinth level 59 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work above plinth level upto floor V level 60 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 61 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 62 Supplying and fixing truncated square natural stone pillar of 2.5mtr height, 28cm base width,20cm top width, 30cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain)/manual) etc. complete. 63 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes 64 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work 65 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 66 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). 67 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 68 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 69 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 70 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 71 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications: Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm 72 Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick 73 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm 74 7Resting Pavilion -Type 2 (2 Nos)Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 75 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 76 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand) 77 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 78 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 79 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level 80 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 81 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 82 Supplying and fixing truncated square natural stone pillar of 2.5mtr height, 28cm base width,20cm top width, 30cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain)/manual) etc. complete. 83 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes 84 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work 85 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 86 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). 87 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 88 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 89 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 90 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 91 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications: Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm 92 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick 93 8 Resting Pavilion-Type 3 (6 Nos)Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 94 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 95 Random rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand) 96 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 97 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers 98 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level 99 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 100 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 101 Supplying and fixing truncated square natural stone pillar of 2.5mtr height, 28cm base width,20cm top width, 30cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain)/manual) etc. complete. 102 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes 103 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work 104 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 105 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). 106 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 107 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 108 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 109 Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick 110 9 Resting Pavilion- Type 4 (15 Nos)Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 111 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 112 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 113 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 114 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 115 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work upto plinth level 116 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 117 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 118 Supplying and fixing truncated square natural stone pillar of 2.5mtr height, 28cm base width,20cm top width, 30cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain)/manual) etc. complete. 119 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes 120 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work 121 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 122 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). 123 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 124 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 125 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 126 Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) 25 mm thick 127 10 Resting Pavilion-Type 5 (2 Nos)Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 128 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 129 Random rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand) 130 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 131 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 132 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work upto plinth level 133 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 134 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 135 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 136 Supplying and fixing truncated square natural stone pillar of 2.5mtr height, 28cm base width,20cm top width, 30cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain)/manual) etc. complete. 137 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes 138 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work 139 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 140 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). 141 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 142 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 143 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 144 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 145 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications: Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm 146 Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick 147 11 Entrance PavilionEarth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 148 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 149 Random rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand) 150 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 151 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 152 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work upto plinth level 153 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 154 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 155 Exposed Laterite masonry with neatly dressed laterite stone of size 30X20X20cm or nearest size in cement mortar 1:6 for superstructure above plinth level up to floor two level including all cost of materials, labor charges etc. 156 Supplying and fixing truncated square natural stone pillar of 2.5mtr height, 28cm base width,20cm top width, 30cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain)/manual) etc. complete. 157 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes 158 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work 159 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 160 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). 161 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 162 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 163 12 mm cement plaster of mix:1:4 (1 cement : 4 fine sand) 164 Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) 25 mm thick 165 12Information / Aid post (4 Nos)Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 166 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 167 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 168 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 169 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers 170 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work upto plinth level 171 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 172 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 173 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 174 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work 175 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 176 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). 177 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 178 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 179 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 180 Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick. 181 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm 182 13Stone Bridge Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 183 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 184 Random rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand) 185 Stone work plain ashlar in arches in superstructure upto floor V level in cement morter 1:3 (1 cement : 3 coarse sand) including centering, shuttering and pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with and admixture of pigment matching the stone shade. One face dressed Coursed rubble 186 14 DrainageEarth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 187 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 188 Centering and shuttering including strutting, etc. and removal of form for: Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 189 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 190 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 191 Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 192 15 Handrailing work Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes 193 16Resting Pavilion-Type 6 (1 Nos)Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 194 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 195 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand) 196 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 197 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 198 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work upto plinth level 199 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 200 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 201 Supplying and fixing truncated square natural stone pillar of 2.5mtr height, 28cm base width,20cm top width, 30cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain)/manual) etc. complete. 202 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 203 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work 204 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 205 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately ). 206 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 207 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 208 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 209 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 210 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications: Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm 211 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick 212 17Resting Pavilion-Type 7 (4Nos) Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 213 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 214 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand) 215 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 216 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 217 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work upto plinth level 218 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 219 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 220 Supplying and fixing truncated square natural stone pillar of 2.5mtr height, 28cm base width,20cm top width, 30cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain)/manual) etc. complete. 221 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 222 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work 223 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 224 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). 225 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 226 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 227 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 228 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 229 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications: Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm 230 Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick 231 18 Resting Pavilion-Type 8 (4Nos)Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 232 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 233 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand) 234 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 235 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers 236 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work upto plinth level 237 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 238 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 239 Supplying and fixing truncated square natural stone pillar of 2.5mtr height, 28cm base width,20cm top width, 30cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain)/manual) etc. complete. 240 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 241 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work 242 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 243 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). 244 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 245 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 246 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 247 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 248 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications: Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm 249 Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick 250 19 Providing granite pillars and Kalvilakku Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 251 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 252 Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete 253 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level 254 Supplying and fixing truncated natural stone Kalvilakku with 9 vilakku thattu of 5.5mtr height, 200cm base width, the design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain)/manual) etc. complete. 255 Supplying fixing truncated square natural stone pillar of 4.5mtr height, 60cm base width,60cm top width, 90cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain)/manual) etc. complete. 256 20 Connecting bridge from Core area to Devi templeEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. All kinds of soil 257 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. Hard rock (blasting prohibited 258 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 259 Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. Hard rock (blasting prohibited) 260 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 261 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work above plinth level upto floor V level 262 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 263 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer. G.I. pipes 264 21 Approach Road Below Connecting bridge from core area to Devi temple Excavation in Soil with Dozer with lead upto 100 mExcavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections. 265 Compacting Original Ground(ii) Compacting original ground supporting subgradeLoosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per Technical Specification Clause 303.5.2. 266 Granular sub-base/base/surface course with local materials (Table 400.13) by mix in place method normal. Construction of granular sub-base by providing local material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at once and compacting with smooth wheel roller to achieve the desired density complete as per Clause 401.4 as per Technical Specification Clause 408.(ii)Using Gravel mix soil. 267 22 Administrative block Unit-1 (2Nos) Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 268 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 269 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 270 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 271 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers 272 Centering and shuttering including strutting, etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform 273 Centering and shuttering including strutting, etc. and removal of form for: Stairs, (excluding landings ) except spiral - staircases) 274 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work upto plinth level 275 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 276 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 277 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 278 Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete 279 Exposed Laterite masonry with neatly dressed laterite stone of size 30X20X20cm or nearest size in cement mortar 1:6 for superstructure above plinth level up to floor two level including all cost of materials, labor charges etc. 280 Supplying and fixing truncated square natural stone pillar of 2.5mtr height, 28cm base width,20cm top width, 30cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading ( using Mechinery( crain)/manual) etc complete. 281 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes 282 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work 283 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 284 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). 285 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 286 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 287 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 288 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) 289 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 290 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications: Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm 291 Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick 292 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 600 mm. 293 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 294 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood 295 Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge. Second class teak wood Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)Second class teak wood35 mm thick shutters 296 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick: Second class teak wood 297 Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings/ wooden frames with rawl plugs screws etc. 298 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer. G.I. pipes 299 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 300 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) 301 23 Administrative Block Unit-2 (1 No)Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 302 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 303 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand) 304 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 305 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers 306 Centering and shuttering including strutting, etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform 307 Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) 308 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work upto plinth level 309 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 310 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 311 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 312 Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete 313 Exposed Laterite masonry with neatly dressed laterite stone of size 30X20X20cm or nearest size in cement mortar 1:6 for superstructure above plinth level up to floor two level including all cost of materials, labor charges etc. 314 Supplying and fixing truncated square natural stone pillar of 2.5mtr height, 28cm base width,20cm top width, 30cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain)/manual) etc. complete. 315 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 316 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work 317 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 318 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). 319 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 320 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 321 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 322 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) 323 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 324 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications: Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm 325 Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick 326 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 600 mm. 327 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 328 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood 329 Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge. Second class teak woodProviding and fixing panelled or panelled and glazed shutters for doors, windowsand clerestory windows fixing with butt hinges of required size with necessaryscrews, excluding panelling which will be paid for separately, all complete as perdirection of Engineer-in-charge. (Note:- Butt hinges and necessary screws shallbe paid separately)Second class teak wood35 mm thick shutters 330 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick: Second class teak wood 331 Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings/ wooden frames with rawl plugs screws etc. 332 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer. G.I. pipes 333 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 334 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) 335 1 Planting of Trees and ShrubsDigging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) Holes 60 cm dia, and 60 cm deep 336 Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment). 337 Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) : Screened through the sieve of I.S. designation 20 mm 338 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-incharge (excluding cost of earth and manure) 339 Supplying and stacking at site Neem Cake from approved source, including carriage upto 5 km lead complete (Neem cake measured in 50 kg gunny bags will be reduced by 1 kg per bag for payment) 340 Supplying of trees (Ficus microcarpa) with multi branches, disease free, healthy in big poly bags of size 30 cm with a girth of 10 cm as per direction of the officer-in-charge. 341 Supplying of trees(Ficus racemosa) with multi branches, disease free, healthy in big poly bags of size 30 cm with a girth of 10 cm as per direction of the officer-in-charge. 342 Supplying of trees (Ficus relegiosa) with multi branches, disease free, healthy in big poly bags of size 30 cm with a girth of 10 cm as per direction of the officer-in-charge. 343 Supplying of trees(Ficus benghalensis) with multi branches, disease free, healthy in big poly bags of size 30 cm with a girth of 10 cm as per direction of the officer-in-charge. 344 Supplying of trees(Cassia Fistula) with multi branches, disease free, healthy in big poly bags of size 30 cm with a girth of 10 cm as per direction of the officer-in-charge. 345 Supplying of trees(Mimusops elengi) with multi branches, disease free, healthy in big poly bags of size 30 cm with a girth of 10 cm as per direction of the officer-in-charge. 346 Supplying of trees(Saraca asoca) with multi branches, disease free, healthy in big poly bags of size 30 cm with a girth of 10 cm as per direction of the officer-in-charge. 347 Supplying of trees(Azadirachta indica) with multi branches, disease free, healthy in big poly bags of size 30 cm with a girth of 10 cm as per direction of the officer-in-charge. 348 Supplying of trees(Strobilanthes kunthiana) with multi branches, disease free, healthy in big poly bags of size 30 cm with a girth of 10 cm as per direction of the officer-in-charge. 349 Supplying of trees(Ocimum tenuiflorum) with multi branches, disease free, healthy in big poly bags of size 30 cm with a girth of 10 cm as per direction of the officer-in-charge. 350 Supplying of trees(Nyctanthes arbor tristis) with multi branches, disease free, healthy in big poly bags of size 30 cm with a girth of 10 cm as per direction of the officer-in-charge. 351 Planting of trees including watering providing required support ,dressing of surface etc complete as per the direction of officer in charge. (excluding cost of plant) 352 Planting of shrubs including watering providing required support ,dressing of surface etc complete as per the direction of officer in charge. (excluding cost of plant) 353 Complete maintenance of trees & Shrubs for 1 Year (Outside garden features), jobs like making of basin at regular interval i/c watering, weed free site & pruning and replacing the dead trees with same specification and height as per direction of officer in charge. Water arrangements to the plantation site need to be done by Contractor. 354 Providing and fixing M. S. tree guard 45 cm square in plan, height 1.20 metre above ground level and 0.40 metre below ground level. The vertical members shall consist of four nos. angle iron of size 25x25x3 mm, 1.6 m long, one at each corner and 8 nos flat iron of size 25x3 mm, 1.2 m long. The vertical mambers shall be welded to 4 nos. 25x6 mm M. S. flats placed horizontally around the vertical member of the cage. One name plate of 1mm thick M.S. sheet of size 250x100 mm shall be welded to the tree guard near the middle height and lettered CPWD/ PWD/ any other approved name. The tree guard shall be fixed to the ground by making suitable holes and by embedding four corners leg in the ground, including refilling the earth, compaction etc. complete. The tree guard shall be painted with two or more coats of synthetic enamel paint of approved brand and manufacture over a coat of primer, completein all respect. 355 2 SignagesEarth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 356 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 357 Providing and fixing stone slab of Sectional Dimension 600mm x 1500mm ,Thickness 100mm ,cutted to required dimension and shape with fine dressed surface, including the all lead ,lift loading, unloading and transportation etc complete. 358 Providing and fixing signage board made up of 1mm thick, 304 grade stainless steel sheet brushed finish of required dimensions as per the drawing with given information etched on it, and made in given profile as shown in dwg including cost of all Labours and Materials etc complete. 359 1ElectrificationWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C 360 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm 361 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm 362 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 363 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 364 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch 365 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch 366 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet 367 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet 368 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) 369 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 95 sq mm 370 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm) 371 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 4 sq mm with factory made clamp 372 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) 373 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages, colour washing etc. as required.4 core 6 sq mm with factory made clamp 374 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm) 375 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp 376 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 377 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp 378 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 379 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG) 380 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor (8 SWG) 381 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG) 382 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) 383 Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required.CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) 384 Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc. 385 Supply and providing heavy duty A section neoprene gasket in the panel boardA section neoprene beeding suitable for 1.60/ 2.00 mm sheet 386 Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC) 387 Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board 388 Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber,suitable size nut & bolt, providng heat shrink sleeves etc. as required. 389 Supply and providing copper earth bus in the panel board 390 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 391 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 392 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps 393 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 394 Supply Conveyance Installation Testing and commissioning of Philips make or equivalent BGP 300 LED 528 757 PSU 35W GI Post Top Lantern fittings having efficiency of 100 and above LM/W, Diffused optic 440V Driver P2P protection high cut off @ 325V +_ 15V auto restart with in built surge protection 7KV with pressure Die cast aluminium housing 4000K with IP 68 protection in position and giving connections etc. as required. 395 Supply Conveyance Installation Testing and commissioning of Wipro make or equivalent Arcus Step Light LT51-750-XXX-30-XX Compact non corrosive Aluminium body with high lumen output of 7W LED 3000K in position and giving Connections etc. as required. 396 Supply Conveyance Installation Testing and commissioning of Philips make or equivalent BGP 150LED 520WW 8W LED Spike Light with Robust diffuser IP design 65/IK06 protection housing with Die cast aluminium with tempered glass for precise light distribution in position and giving connections etc. as required 397 Supply Conveyance Installation Testing and commissioning of Philips make or equivalent BCP151 LED NW PSU 220-240V 7043 17W Bollard light having efficiency of 53 LM/W housing by pressure Die cast Aluminium IP65 protection with mounting wall bracket dimension of 177X395X700mm with surge protection 4KV THD<10% conforming to IEC60598 in position and giving connections etc. as required. 398 Supply Conveyance, installation, testing and commissioning of Philips make or equivalent Tango BVP 483 LED 185CW SWB PSU GR Flood light best in class lens design and optical integration with single die-cast ceramic base high power LED with 10KV SPD is provisional inside luminaire dimmable option 1- 10V integrated flood optics to ensure uniform distribution, maintenance free system ideal for area lighting in position and giving connections etc.as required. 399 Supply Conveyance Installation Testing and commissioning of 4M Decorative Lamp Poles of Crompton Make BRASSO Lamp Poles in position and necessary nut and bolts etc. as required. 400 Supply and Providing Hensel make Junction Box size 93X93X62MM with insulation voltage 690V AC/DC made with Thermo Plastic with IP65 protection in accordance with IEC60670- 22 knock out for cable Entry/Exit as required. 401 Supply and Providing Hensel make Junction Box size 104X104X70MM with insulation voltage 690V AC/DC made with Thermo Plastic with IP65 protection in accordance with IEC60670- 22 knock out for cable Entry/Exit as required. 402 Supply and Providing Hensel make Junction Box size 130X130X77MM with insulation voltage 690V AC/DC made with Thermo Plastic with IP65 protection in accordance with IEC60670- 22 knock out for cable Entry/Exit as required. 403 Supply Fabrication of Feeder Pillar Box of size 1.5M H X1.2M WX0.30M in position as directed by Engineer in charge ( The Fabrication details specified in the Fabrication Item. 404 Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. 405 Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size 406 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. 407 Supply and providing the 25 x3 mm brass bolt and nut with washers on the existing MS box /Container/earth bus etc. as required including drilling necessary holes as required. 408 Supply and providing the 25 x 6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required. 409 PLUMBING, SANITARY & IRRIGATION 1 SEWAGE & DRAIN SYSTEM INTERNAL AND EXTERNAL Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm dia 10 Kgf/cm2 410 Providing and fixing PVC pipes includes jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia 10KGF/cm2 411 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.32 mm dia 10.Kgf/cm2 412 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2 413 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work including cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2 414 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2 415 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall 416 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall 417 Providing , fixing , testing and commissioning pvc multy inlet (110x75x50x50x50) floor trap of self cleansing design with or without vent arm complete, including cost of masonry or concrete supports cutting and making good the walls and floors where ever required 418 Providing , fixing , testing and commissioning pvc P trap with multy inlet or single inlet connection of required sizes of self cleansing design with or without vent arm complete, including cost of masonry or concrete supports cutting and making good the walls and floors where ever required 419 Providing, fixing, testing and commissioning at site 100x100 mm square C.P.cast brass or stainless steel Grating Cover with protection from cockroaches of matching size of multi inlet or P trap complete in all respects. 420 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow 421 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Bend 422 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63 dia 45 degree Elbow 423 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia vent cowl 424 Providing and fixing PVC moulded fitting / accessories for Rigid PVC pipes, including jointing with PVC solvent cement-63 mm dia Socket /coupling 425 Providing and fixing PVC moulded fitting / accessories for Rigid PVC pipes, including jointing with PVC solvent cement-63 mm dia Y 426 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia End cap 427 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63x50 mm dia Reducer 428 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Elbow 429 2 CP AND SANITARY FIXTURESProviding and fixing of Floor Mounted European type W.C. pan with seat cover and external Flush tank with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:Make: Hindware/Jaquar/Equivalent 430 Providing and fixing of Wall Mounted European type W.C. pan with seat cover and external flush tank with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: Make : Jaquar/Hindware/Parryware/Equivalent 431 Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. 432 Supplying,fixing & testing of Concealed Stop Cock with Over Head Shower including all accessories ,cutting and making good the walls wherever required Make : Jaquar/Hindware/Parryware/Equivalent 433 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap 434 Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, Collar and bush approved quality and colour .15 mm nominal bore with 45 cm length 435 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore 436 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore 437 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighting not less than 190 gms 438 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of430x260x350 mm or 340x410x265 mm sizes respectively. 439 Supplying and Fixing of C.P. Urinal push cock of approved quality. Make : Jaquar/ Hindware/ Parryware/ Equivalent 440 Supplying and Fixing of Urinal Partition of approved quality. Make : Jaquar/ Hind ware/ Parry ware/ Equivalent 441 Supplying and Fixing CP Robe Hook of approved Quality Make : Jaquar/ Hind ware/ Parry ware/ Equivalent 442 Supplying and Fixing CP Soap Dish of approved Quality Make : Jaquar/ Hind ware/ Parry ware/ Equivalent 443 Supplying & fixing of 4 nos of Grab bar and 1 no of Folding type Grab bar with necessary fittings at both side of commode for physically challend persons all complete as directed. Make :Jaquar/Hindware/Parryware/Equivalent 444 3INTERNAL WATER SUPPLYProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes 445 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes 446 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost ofcutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.32 mm nominal outer dia pipes 447 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 40 mm nominal outer dia pipes 448 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm nominal outer dia pipes 449 Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreVertical 450 Providing and fixing Y Strainer of approved quality of following sizes. Make: Zoloto / SKS/ Leader/ Equivalent 100mm dia 451 Providing and fixing CI Butterfly valve of approved quality as per IS 13095 of following sizes. Make: Zoloto/SKS/Cim/Equivalent 65mm dia 452 Providing and fixing CI Butterfly valve of approved quality as per IS 13095 of following sizes. Make: Zoloto/SKS/Cim/Equivalent 100mm dia 453 4 IRRIGATION-PVC PIPING WORKS Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm dia 10 Kgf/cm2 454 Providing and fixing PVC pipes includes jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia 10KGF/cm2 455 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.32 mm dia 10.Kgf/cm2 456 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge 40 mm dia 10Kgf/cm2 457 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 10Kgf/cm2 458 Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge. 63 mm dia 6Kgf/cm2 459 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 10 Kgf/ cm2 460 5DRIP AND ACCESSORIESSupply, Fixing & Commissioning of flexible,kink resistant 16mm Blank tubing and resistance to UV damage and algae growth brown in colour and wall thickness 1.2mm, pressure rating 0.58 to 4.1Bar etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 461 Supply, Fixing & Commissioning of Xeri bug emitter pressure compensating with self flushing emitter, and selfpiercing barbs,flow rates 1 GPH UV resistant colour coded with working pressure 1.0 to 3.5bar etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 462 Supply,Fixing & commissioning of 3 Large Capacity Disc Filters for submain filteration Have High Flow & Low Maintenance With a Solid Build,Maximum Flow Up to 110 gpm (25m³/hr), Maximum Pressure 116 psi (8 bar), Maximum Temperature Up to 140ºF (60ºC). 463 Supply,Fixing & commissioning of 21/2 Large Capacity Y Type Disc / Screen Filters for submain filteration Have High Flow & Low Maintenance With a Solid Build,Maximum Flow Up to 110 gpm (25m³/hr), Maximum Pressure 116 psi (8 bar),Maximum Temperature Up to 140ºF (60ºC) etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 464 Supply,Fixing & commissioning of 63mm Y Type Disc / Screen Filters for submain filteration Have High Flow & Low Maintenance With a Solid Build,Maximum Flow Up to 110 gpm (25m³/hr), Maximum Pressure 116 psi (8 bar),Maximum Temperature Up to 140ºF (60ºC) etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 465 Supply, Fixing & commissioning of 40mm Y Type Disc / Screen Filters for submain filteration Have High Flow & Low Maintenance With a Solid Build,Maximum Flow Up to 110 gpm (25m³/hr), Maximum Pressure 116 psi (8 bar),Maximum Temperature Up to 140ºF (60ºC) etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 466 Supply, Fixing & commissioning of 32mm Y Type Disc / Screen Filters for submain filteration Have High Flow & Low Maintenance With a Solid Build,Maximum Flow Up to 110 gpm (25m³/hr), Maximum Pressure 116 psi (8 bar),Maximum Temperature Up to 140ºF (60ºC) etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 467 Supply,Fixing & commissioning of 25mm Y Type Disc / Screen Filters for submain filteration Have High Flow & Low Maintenance With a Solid Build,Maximum Flow Up to 110 gpm (25m³/hr), Maximum Pressure 116 psi (8 bar),Maximum Temperature Up to 140ºF (60ºC) etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 468 Supply,Fixing & commissioning of 20mm Y Type Disc / Screen Filters for submain filteration Have High Flow & Low Maintenance With a Solid Build,Maximum Flow Up to 110 gpm (25m³/hr), Maximum Pressure 116 psi (8 bar),Maximum Temperature Up to 140ºF (60ºC) etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 469 Supply,Fixing & commissioning of self-closing flushing valves that are installed at the end of the irrigation line for effecting flushing of the line at the beginning of every irrigation cycle, thus avoiding the clogging of the emitters /sprinklers through removal of particles, sediments and other impurities from the water. 470 Supply, Fixing & commissioning of 9 - Gauge Galvanized Steal Rod Comes Sharp tips provide easy connection into all soil types, Staple Distribution Tubing , XF Drip Line or XBS Tubing to Finished Grade. Notched Sides. Corrosion -Resistant of TIE DOWN STAKE etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 471 Supply, Fixing & commissioning of Gromatetake off Connects XF Series Drip Line and Blank Tubing to PVC Mainlines at Low Pressures. 16mm GTO 472 Supply,Fixing & commissioning of High Quality Barbs Grab Tubing for a Secure Fit. Unique Barb Design to Reduce Insertion Force. Non - Obtrusive Brown Colored Fittings of 17mm Tee . etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 473 Supply,Fixing & commissioning of High Quality Barbs Grab Tubing for a Secure Fit. Unique Barb Design to Reduce Insertion Force. Non - Obtrusive Brown Colored Fittings of 17mm COUPLING. etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 474 Supply,Fixing & commissioning of High Quality Barbs Grab Tubing for a Secure Fit. Unique Barb Design to Reduce Insertion Force. Non - Obtrusive Brown Colored Fittings of 17mm ELBOW. etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 475 Supply,Fixing & commissioning of 17mm End cap S Type for dripline closure at the end of the dripline etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 476 6 SPRINKLERS AND ACCESSORIES Supply, Fixing & commissioning of Pop up spray head Spray bodies, with Rotary nozzle having mutilple stream MPR spray having Co-moulded wiper seal is molded into the cap and features an encased plastic cage to provide unmatched resistence to grit, nozzle having capable of covering 5.2-7.2m at 1.4 - 3.8 Bars pressure, True flushing mechanism,Thick streams and large water content & Low precipitation rate and the enviroment. Additionally, the pressure-activated, multi-function seal design assures a positive seal without excessflow-bywhich enables more heads to be installed on the same valve, Two-piece ratchet mechanism, Features is Precision controlled flush at pop-down clears debris from unit, Construction of time-proven UV_resitant plastic. Pop spray body shall with stand upto 4.8 bar. Built-in Seal-A-Matic™ (SAM) check valve. Traps water in lateral pipes in elevation changes of up to 14 feet (4.2 m). PRS Maintains constant outlet pressure at 30 psi or 45 psi at varying inlet pressures.etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 477 Supply, Fixing & commissioning of 1/2 Pop up Connecting Swing joint Assembly. The tubing shall be made of polyetylene having wall thickness of 2.3mm ,a working pressure of 5.5 kg/cm2 at 43oC and a surge pressure of 16.6 kg/cm2. Flex pipe textured for wet conditions.The fittings shall be made of UV resistant thermo plastic etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge..SA Series. 478 Supply, Fixing & commissioning of PVC service saddle of varying size upto 63mm dia with pressure rating of PN 10 etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 479 7VALVES AND ACCESSORIESSupply,Fixing & commissioning of PVC Single Union Ball Valve,security pivot to maintain lever in space,double water tight joint,direct injection stem,Stem O-Ring, non mechanical ,ball Seals with backing seals and with a base which permits maximum penetration into the valve of size 75mm with pressure rating PN 10 etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 480 Supply,Fixing & commissioning of PVC Single Union Ball Valve,security pivot to maintain lever in space,double water tight joint,direct injection stem,Stem O-Ring, non mechanical ,ball Seals with backing seals and with a base which permits maximum penetration into the valve of size 63mm with pressure rating PN 10 etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 481 Supply,Fixing & commissioning of PVC Single Union Ball Valve,security pivot to maintain lever in space,double water tight joint,direct injection stem,Stem O-Ring, non mechanical ,ball Seals with backing seals and with a base which permits maximum penetration into the valve of size 40mm. with pressure rating PN 10 etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 482 Supply,Fixing & commissioning of PVC Single Union Ball Valve,security pivot to maintain lever in space,double water tight joint,direct injection stem,Stem O-Ring, non mechanical ,ball Seals with backing seals and with a base which permits maximum penetration into the valve of size 32mm. with pressure rating PN 10 etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 483 Supply,Fixing & commissioning of PVC Single Union Ball Valve,security pivot to maintain lever in space,double water tight joint,direct injection stem,Stem O-Ring, non mechanical ,ball Seals with backing seals and with a base which permits maximum penetration into the valve of size 25mm. with pressure rating PN 10 etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 484 Supply,Fixing & commissioning of a double acting air and vaccum release 1/2 Air release valve . The Air release valve shall be capable of both releasing and admitting air from and into the line. The working pressure shall be 5 bar. Only for Drip Irrigation etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 485 Supply,Fixing & commissioning of 18 Jumbo Valve Box with greenlid and corrugated structure with unique shovel access slot and bolt hole knockout & Having Dimensions @ Top Opening 10 Dia & Bottom Opening 12 13/16 Dia etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 486 Supply,Fixing & commissioning of 12 Rectangular Standard Valve Box with greenlid and corrugated structure with unique shovel access slot and bolt hole knockout & having Dimensions @ Top Opening:18 1/4 L X 13 W & bottom opening :21 1/4 L X 15 15/16W X 12 H etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. PVB/VB 487 Supply,Fixing & commissioning of 3/4th Quick coupling valve made up of solid brass with locking cover corrosion resistant and stainless steel spring etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 3RC 488 Supply,Fixing & commissioning of 3/4th Key threads into top of QCV to provide water access etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 489 Supply,Fixing & commissioning of 3/4th Hose Swivel Made up of Solid Brass Swivels up to 360 degrees to allows hose to be pulled in any direction & Also to prevent Hose Damage etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. SH-0 490 8PUMPING ACCESSORIES Supply,Fixing & commissioning of Pressure release valve 2 with pressure setting from 0 to 7 Bar etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge 491 9AUTOMATION EQUIPMENTSupply,Fixing & Commissioning of Direct burial14 Awg x 2 Maxi cable with PVC insulated UL stndard 493 with impregnated polyethene jacket and soft annealed tin coated copper confirming to ASTM B-33 for two way communication between decoder controller and decoders complete. 492 Providing and fixing PVC pipes includes jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia 10KGF/cm2 493 Supplying ,fixing & commissioningdirect bury -on wire Connector with strain relief UL486D Certified with water proof silicon sealent,fits wire from 22ga to 66ga asper specification complete DBRY 494 Supply,Fixing & Commissoning of ASTM Station Modular Controller UV resistant,wall mount case,with LCD display ,non volatile memory for 100years,10KV surge protectionwith removable front panel and programmable under battery in office,total run time calculator ,short detect errors,one touch watering,wityh contract default programe s,slow closing valve removable battery with sensor terminals Work has to be executed as per the approved drawings and/or as per the directions of the engineer-incharge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete. 495 Supply,Fixing & commissioning of 63mm Solenoid globe angle inlet Valves with fabric reinforced Nitrile diaphram Material and rugged PVC durable glass -filled nylon construction ,compatible with and slow closing to prevent water hammer,pressure rating upto 10.4 KSC and maximum flow of 150GPM ,max water temp. upto 42degree centigrade, with 24AC solenoid,current rating 0.41A @60Hz,coil resistance30ohm with provision to attach PRS-Dial PGA Pressure Regulation Optional PRS-D 496 Supply,Fixing & commissioning of Automatic rain shut off Device,latching hinge with multiple rain fall setting 5mm to 20mm UL CUL listed and CE approved RSD BEX
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
25.
Housing Urban and Rular Development #10392168 Price Bid
Amc Of Ei At Nigs, Medinipur Sadar- Day To Day Annual Maintenance Of Electrical Installations Including S And D Of Maintenance Materials - Day to day Annual maintenance of Electrical installations of NIGS, Medinipur Sadar, Paschim Medinipur.Charges for providing 1 No Electrician, 1 No Helperfor 1(One)shift as per Scope of work, terms & condition given below. every Day(incl. holy day) including emergency break down etc. of beyond maintenance hour if required] 2 S & D of 18W PC body LED Tube light.(Make - Crompton, Cat No.- LTT8-20 or equivalent of Wipro/Phillips) 3 S & D 9W 900 lumen LED bulb B22. (Make- Philips/Crompton/Wipro) 4 S & D of Push Holder For Tube light.(Make- Philips/Crompton/Wipro) 5 S&D of Angular batten Holder (Anchor) 6 S & D 2.5 mF capacitor metal body for ceiling fan.(Make:Tibcon) 7 S & D Fan Bearing 6201(Make -SKF/Tata) 8 S & D Fan Bearing 6202(Make -SKF/Tata) 9 S & D 415 V 63A TP MCB of Breaking capacity 10kA & C characteristics(Make: L&T/Havells/Legrand) 10 S & D 240 V 6-32A SP MCB of Breaking capacity 10kA & C characteristics(Make: L&T/Havells/Legrand) 11 S&D 240V 40A DP MCB Isolator (Make: L&T/Havells/Legrand) 12 S&D 125A HRC HN type fuse(L&T/ Siemance/Havells) 13 S&D 63A HRC fuse HF type fuse(L&T/Siemance/Havells) 14 S & D of 240 V 6 A Piano key type switch(Make - Anchor) 15 S & D of 240 V 16/20 A Piano key type switch(Make - Anchor) 16 S & D of 240 V, 6A plug socket(Make - Anchor) 17 S & D of 20 A plug socket(Make - Anchor) 18 S & D of Socket type fan regulator (Step type)(Make - Anchor) 19 S & D of 1100V grade FR PVC insulated 1.5sqmm(22/0.3) stranded copper wire(Make - Finolex/RR/Havells/KEI/Plycab) 20 Supply of 240V AC 1200mm Sweep ceiling fanscomplete with all accessories having the following specification. (Make-Usha triker plus /Orient Summer cool or equivalent of Crompton High Speed) 21 S & D of industrial LED batten for fixing 1200mm retrofit 18/20W tube light(Make - philips/ Crompton/Wipro) 22 Single Industrial Batten 23 Twin Industrial Batten 24 SCOPE OF WORK:- I) FOR EI MAINTENANCE:-a) The primary objectives of preventive and corrective maintenance are to minimize electrical breakdowns and faults, prevent fire hazards arising from electrical short circuits and faults, and reduce downtime. Any fire hazard incidents resulting from short circuits, or the falling of ceiling fans, luminaries, etc., due to inadequate maintenance will be treated with utmost seriousness. The maintenance agency shall be held accountable for such incidents.b) The electrical installation includes entire cabling network and wirings, BDB’s, PDB’s power & distribution cables,Compound lights, fittings & fixture. LT panels,UPS system etc.c) working time: 1 no Electrician, 1 no Helper FOR 1(One) shift every Day including holy day. At the time of emergency breakdown etc. of beyond maintenance hour agency must be provite staff to restore the problem. 25 ADDITIONAL & SPECIAL TERMS & CONDITIONS OF CONTRACT FOR EI MAINTENANCE:- The agency must provide measuring/operating equipment such as digital multimeter, clambmeter, thermal imeger, earth regeistance tester, low voltage insulation mager, hot air blower, air blower, screw driver set, all type of spaner, cable puncher etc. to the employed staff. 26 The agency shall maintain one Call Book which shall record all the calls alongwith remedial action taken, duly verified by the Junior Engineer/Assistant Engineer periodically. 27 Separate Log book is to be maintained for all L.T. installation . The daily record of the Log book is to be signed by the licensed Supervisor of the contractor and verified & signed by concerned Junior Engineer & Assistant Engineer; and the same should be sent to the Executive Engineer through proper channel at the time of submission of bills. 28 Recording of various electrical parameters (with co. own tools/equipments) of different L.T. panel board, BDBs, Main switches etc, are to be made in Log book in regular manner and the necessary working report in this respect to be submitted monthly to the concerned Assistant Engineer & Junior Engineer every day. Thermal imager should be used in measuring/observing temperature rise of electrical equipments like Cable, BDBs, L.T. panel boards, AC, Light fittings, etc. regularly to find out any abnormalities and the measurements are to be recorded in Log book compulsorily in proper manner every day. 29 In case, any abnormal reading is noticed, then the same should be rectified/set right immediately by taking prompt, appropriate & effective measures/actions by proper recording under intimation to the concerned Assistant Engineer & Junior Engineer. 30 The agency will check and clean all the ceiling fans exhaust fans, stand fans etc. to prevent falling down of those as a measure of safety and maintain a register mentioning fan numbers etc. including keeping those light fittings and fans clean as per the direction of Assistant Engineer or respective Junior Engineer. 31 All the ceiling fans of every Buildings are to be inspected, at least once in 3(three) Months, in respect of Split Pin, Jam nut, fan clamp & suspension arrangement etc. to avoid unwanted falling of Ceiling Fans, failing which responsibility will be fixed up upon the agency (in case of falling of ceiling fans). Report regarding physical condition of Split Pin & Jam Nut must be submitted quarterly in the format prescribed by the EIC. 32 All the fittings, fixture, panel board, PBDB, SPNDB Main-switches & other Electrical Installation inside all the block/floor/buildings as well as for compound lighting installationmust be kept in a tip top condition by cleaning of all the said electrical equipments, dusting off accumulated dirt, cobweb etc. once in a month, and all the cleaning materials like detergent etc. are to be supplied by the agency free of cost. 33 The agency will have to attend all the break-down/fault of any nature involving electrical installation within the scope of contract and restore the same with its own manpower, tools & tackles keeping entries in Log books mentioning type of faults, nature of work done, fault clearance time etc. 34 All incidents of breakdown shall be immediately reported to the concerned Junior Engineer & Assistant Engineer, or direct to Executive Engineer in exceptional circumstances. 35 All the maintenance staff of the contractor should have proper & constant vigilance and check to ensure that there is no sign of overheating, burning smell, discoloration or sparking/chattering at any of BDBs, panel boards,etc. due to overloading or loose connection/termination. Care should be taken to check any highly unbalanced loading at any point.N.B:Periodical check on daily basis by thermal imager scan is required to be carried out for BDB,PDB,Cables, Panels, , Main switches etcand kepping the record and should be reported to the concerned JE on regular basis. 36 The weekly duty roster of the deputed staff should be submitted in advance. 37 The contractor shall issue identity cards to every member of his staff, regular or substitute. No staff will be allowed to perform duty without proper identity card and the agency shall have to assume responsibility for any untoward incident/situation. 38 The authorized licensed supervisor should attend the site regularly and in case of emergency he should attend without any delay and report the incident to the Engineer in Charge. 39 Frequent change of staff is not allowed. Substitute staff list shall have to be submitted at least one week in advance to the Junior/Assistant Engineer. 40 Recording of attendance should in the in the attendance register as per the direction of the EIC and shall be regularly checked and verified by the concerned Junior Engineer/Assistant Engineer. Monthly attendance report should be submitted along with the Bill. 41 Proof of verification of attendance of the staff deputed in the night shift (10 pm to 6 am) by the authority is mandatory for billing purpose. 42 The agency must have separate contact numbers preferably mobile phone numbers for his office and the deputed Supervisor (maintenance team) so that the communication can be easily made in case of urgency. 43 The space for sitting accommodation for the staff of the agency inside the compound will be provided by the PWD/user authority. 44 The Engineer-in-Charge reserves the right for re-allocation of duty to any or all member of the staff as per the requirement of the site or elsewhere. 45 Materials required as replacement during maintenance of electrical installations like fuse wires, screws, nuts, bolts, washers, AL/Cu socket (up to 35 sq. mm.) dusters etc will be supplied Agency so far as practicable, through a separate Issue register to be maintained by the agency at site. 46 The replaced / dismantled materials generated for carrying out breakdown or preventive maintenance or due to civil renovation / dismantling work are to be carried out and deposited to the respective Section Office or any other locations within the compound by the agency by its own labour / arrangements / tools and tackles as per the direction of the Assistant Engineer concerned. If required, the agency will have to dismantle existing electrical installations in connection with any civil renovation / dismantling work and deposit the same to convenient locations as per the direction of the Assistant Engineer concerned by its own labour / arrangements / tools and tackles. 47 Any fault of electrical installations , LT cables and all sub- panels, distribution boards, related main switches, isolators, earthing attachments, compound lights etc has to be detected, attended and restored by the agency by its own man power with the help of the materials (cables, main switches, DBs, wires, HRC fuses etc)available from this department or as per the terms & conditions of this contract. 48 a) Routine checking and preventive maintenance of the electrical installation has to be carried out by the agency daily with a view to ensure uninterrupted power supply within compound. Any negligence in the part of the agency in complying with any of the above described terms & conditions causing inconveniences to public service will be viewed otherwise and is subject to unilateral penalty, be it detected on the spot of thereafter (even after payment). 49 b) Routine inspection of the electrical and allied installation shall be carried out by the agency every morning to ensure that all the light/fan socket outlets/ AC/ UPS and other items of work, as may be directed by Junior Engineer/ Assistant Engineer/ Executive Engineer from time to time are in order and action for restoration shall be taken immediately for faulty items. 50 In case of any breakdown caused by cable fault, etc. , the agency will have to restore the power supply either with the materials available with this department or arranging the same temporarily and safely till completion of permanent restoration work as may be directed by the Engineer-in-Charge. 51 Maintenance materials, viz. Incandescent lamps, Main switches, Power DB, SPN BDB, Main & Sub-main cables, fluorescent/LED tubes, Chokes, Ignitors, and Condensers etc. will be supplied by the Department. However auxiliary items like screws, nuts & bolts, washers, fuse wire, insulating tapes etc. will have to be arranged by the agency on its own expense. 52 No materials should be taken out of the maintenance site without the permission and necessary Challan of the site-in-charge. 53 The agency will take care to prepare the requisition of materials required for the maintenance within his jurisdiction well in advance and submit the same to the concerned Junior Engineer so that no delay in maintenance/repair / replacement cause trouble in the system & hampering of the service thereof. 54 The repairing of the different type of light fittings, ceiling fans, exhaust fans etc. have to be done by the agency incl. dismantling and re-fixing the same. (Materials to be supplied by Department). 55 In case of power failure or development of any unfavorable situation, the agency will have to communicate with concerned WBSEDCL authority and extend co-operation to them in restoring of power supply. Meanwhile, the agency will have to operate the switching mechanisms of interconnections among available sources at suitable locations to maintain power supply at important locations by monitoring electrical loads in consultation with concerned Junior Engineer/Assistant Engineer. 56 Any major shut down or fault should be brought to the notice of EIC immediately in writing and over telephone for further course of action. 57 Insulation test with the help of Megger for the entire Electrical Installation as well as earth resistance of the earthing installation for each building and also sub-station are to be carried out in the presence of concerned Assistant Engineer/Junior Engineer once in six months and the result thereof is to be furnished to the Engineer –In-Charge through proper channel alongwith the bill. 58 The agency must have separate offices & separate contact telephone nos. for his site office and main/head/branch office and the same should be intimated to this Department in writing. All telephone calls should be responded without delay. 59 The agency should be responsible for any damage in the installation due to mishandling / mal-operation done by his staff and shall be liable for the compensation for the same which would be recovered from the bill as per direction of E.I.C. and the accused staff should be replaced immediately. 60 If any kind of incapability & negligence are noticed in observing all the above-said terms & conditions, this Department posses the right to deduct the cost from the bills of the contractor on pro-rate basis as determined by the Engineer –In-Charge. In that case, the above-said contract may be terminated without issuing any notice whatsoever and stringent & punitive action may be taken against the contractor as may be decided by the Engineer-in-Charge or higher authority. 61 Valid workman’s permits, electrical licence, Diploma certificate, identity proof etc. are to be furnished for each electrician/workman, helper & Diploma Electrical Engineer/Supervisor engaged by the agency along with the name & contact mobile no. of the persons and all these information with supporting documents are to be submitted in written to the concerned Junior Engineer, Assistant Engineer & Executive Engineer. 62 The contract may be terminated by one month’s notice from either side. 63 Any negligence in the part of the agency in complying with any of the above-mentioned terms and conditions and/or causing inconvenience to public service will be viewed seriously and shall be subject to unilateral penalty, be it detected on the spot or thereafter (even after payment of bills). 64 The agency should have been responsible for any damage in the installation due to mishandling or mal-operation. If so, the cost for rectification or replacement will be recovered from the bill on proportionate and the incident will be counted while issuing the performance report. 65 The agency will have to maintain log books in such a manner so that at least one log book may always be made available at site as and when asked for. 66 Bills should be submitted quarterly or as per direction of EIC, keeping at least one spare log book at site. Payment will be made as per PWD norms against placement of bills supported by log book and duly verified by the Junior Engineer / Assistant Engineer. 67 Labour laws : Before undertaking the work as per order, agency must produce labour license obtained from the Assistant Labour Commissioner/Dy. Labour Commissioner’s office in the Region in compliance with the provisions of Central Labour Regulation & Abolition Act, 1970 and the rules made thereunder. He should comply with all labour laws to protect the labourers engaged by him. The successful bidder after placement of the order shall have to comply with following in order to get payment :a) Heshall have to follow the rules and regulations of the prevailing Acts of Central and State Governments.b) Heshall be responsible for compliance of statutory obligation under the Central Labour (R&A) Act, 1978, Minimum Wages Act, 1948, Payment of Wages Act 1936, Bonus Payment Act, 1956, and also be responsible for payment of contribution (Both employer and employee’s) under Provident Fund Act & Employees’ State Insurance Act,1952 in respect of the employee. c) Heshall be solely responsible for any accident, occurring if any, during the course of the work or any injury to any person and in the event of any such accident/injury he will be held responsible and must pay proper compensation for the same as per Workmen’s Compensation Act, 1923 (when Employee State Insurance Act 1948 is not applicable); d)No labour of minor age should be employed; e) Statutory minimum wages for all categories of labour are to be paid as per notifications issued by the appropriate authority of the Government from time to time: 68 Uniform, safety shoes, helmet, raincoat, umbrella, gumboot, torch/ emergency light, etc. and all types of tools and tackles (Like digital multimeter, tongtester, earth regeistance tester, low voltage insulation mager, hot air blower, air blower, screw driver set, all type of spaner, cable puncher, lader etc) are to be provided by the agency to its staff. 69 All the issues related to the safety of the staff should be taken care by the Agency itself. 70 In case of any mishap or accidental injury to any member of the staff deputed by the agency, the whole responsibility is to be borne by the agency but should be informed to the EIC immediately. 71 Any unethical/unruly attitude/behaviour or activity of the agency or any of his deputed staff should be viewed seriously and legal action would be taken accordingly by this end. 72 The philosophy of “Public Interest” would be the ‘motto’ of this maintenance contract. Any deviation may be viewed otherwise and action taken accordingly. 73 It will be the duty and responsibility of the agency to ensure strict compliance of the provisions of the contract. Should any major or recurring deviation or negligence be observed/detected in execution of the contract by the agency during any scheduled/surprise inspection of the higher authority, penal action will be taken with retrospective effect without any further reference/correspondence, and without any prejudice to the right of the Engineer-in-Charge to terminate the contract by invocation of any of the clauses of the contract. 74 The Executive Engineer/ Assistant Engineer the right to depute any members of the maintenance staff to other site, in exigency of public service, restore normally or assist other team members working there. 75 The Maintenance Personnel, deputed by the agency should be a permanent resident of West Bengal with valid Voter / Aadhar Identity Card and should possess valid Workman Permit/ License, as mentioned below, issued by Directorate of Electricity, Govt. of West Bengal.Sl. No Category of Maintenance Personnel Mandatory Requirement 1. Electrical Supervisor SCC Part No. 1,2,3,4,5, 6A, 6B, 7A,7B, 10,11& 12 or National SCC /Highly skulled issueded by, DOE, WB2. Skilled Electrician ITI/ Equivalent Certificate Holder Electrical/ SCC Part No. 1,2,3,4,6A,6B, 7A,7B,11, 12 issued by Directorate of Electricity, West Bengal 3.Semi-Skilled ElectricianWorkman Permit i(a) and/ or i(b) and (ii) issued by Directorate of Electricity, West Bengal 4. Unskilled Personnel/ HelperBasic knowledge of Electrical works (Experience Certificate fromreputed Electrical firm required)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
West Bengal View Result →
26.
Heavy Industries and Public Enterprises #10390733 AOC
Vertical Extension & Other Development Works at Academic Block Annex-2 Palayad Campus, Kannur University, Kannur, Kerala under PM-USHA scheme- 1 Civil work -General Structural work 2 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge25 mm average thickness 3 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter 4 Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. 5 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar 6 Core Cutting of RCC slabs(12cm Maxi.thickness) by using mechanical core cutting equipment of required diameter of the pipe in full depth etc to the satisfaction of engineer in charge including all cost and conveyance materials and labours charge etc complete (dia 80-200mm) 7 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 8 Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work ( Payment shall be made on the cross sectional area of R.C.C. or R.B work) as per direction of Engineer-in-charge. 9 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within alead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia 10 Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock 11 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 12 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 13 Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) 14 Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. 15 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 16 Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum). 17 Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 18 Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 19 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 20 Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts 21 Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) 22 Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges 23 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. 24 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more 25 Block work & Finishing Work 26 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 27 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 28 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) 29 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 30 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) 31 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 32 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats 33 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 34 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work 35 Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections. 36 Teracotta Clay Jali work, For Building work, minimum 7.5 cm thick as per approved design and pattern of Engineer in charge in super structure above plinth level upto floor V level with cement mortar 1:4 (1 cement : 4 coarse sand) with neat finish, polishing work all complete. 37 Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with Zinc coating of 120 gms/ (both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wallwith suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre.The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channelof 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufactures specification and direction of engineer in charge all complete.75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG),plaster board conforming to IS : 2095 : (part 3) 1996 (Board with BIS Certification marks) 38 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 39 For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 40 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides 41 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness 42 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm 43 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in- charge. 44 Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm 45 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 46 Joinery 47 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 48 Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer- in-charge. 49 Providing and fixing factory made uPVC white colour casement/casement cum fixedglazedwindowscomprisingofuPVCmulti-chamberedframe,sashand mullion(whereeverrequired)extrudedprofilesduly reinforcedwith1.60+/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriatedimension,EPDMgasket,stainlesssteel(SS304grade)friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mmsizeforfixingframetofinishedwall,plasticpackers,plasticcapsand necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)Note: For uPVC frame, sash and mullion extruded profilesminus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm). 50 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness 51 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood 52 Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin - charge using Anjili/ Jack wood 53 Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc 54 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 55 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm 56 Providing and fixing CP Brass Handle 450mm in all types of doors with the necessary fittings and arrangements all complete. 57 Providingand fixing chromium plated brass handles with necessary screws etc. complete:200 mm 58 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality, with necessary screws etc complete as per direction of Engineer- in- charge. 59 French spirit polishing:Two or more coats on new works including a coat of wood filler 60 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6 mm for diagonal braces and central cross piece 61 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1800X2250 mm. 62 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1000X2200 mm. 63 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately) 64 Providing and fixing SS H handle having min 45 cm length in toughed glass door including all necessary screws etc. complete. 65 Providing and fixing of glass door SS Patch Lock with out handle in toughened glass door including all necessary screws etc. complete 66 Fixing 12 mm thick frameless toughened glass partition of approved brand and manufacture, including top & bottom fixing arrangement and making necessary holes etc. for fixing required fittings, all complete as per direction of Engineer-in- charge. 67 Providing and fixing 3M Fasara frosted etching film of thickness 25 microns self- adhesive of approved colour, shade, and quality with cutting as per approved design and pattern, including cleaning of glass and making surface smooth for fixing of film to the surface, all completed as per the direction of the engineer in charge. 68 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover 69 Providing and fixing ball bearing for rolling shutters. 70 Sanitary and CP Fittings 71 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 72 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 73 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 74 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap 75 Providing and fixing ceramic urinal partitions of standard size as per direction of Engineer-in Charge and of approved shade 76 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore 77 Providing and fixing uplasticised PVC connectionpipe with brass unions: 30 cm length15 mm nominal bore 78 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:150 mm diameter 79 Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore 80 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore 81 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm 82 Providing and fixing white vitreous china laboratory sink with C.I brackets, C.P. brass chain with rubber plug 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required:Size 600x450x200 mm 83 Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in- charge. 84 Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. 85 Flexible pipe32 mm dia 86 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with C.P. brass screws and washers complete. 87 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 88 Providing and fixing SS grating of approved quality and colour. Rectangular type with openable lid150 mm nominal size square 100 mm diameter of the inner hinged grating. 89 Providing and fixing disabled friendly bathroom kit with all accessories including wash closet with soft close seat cover and cistern with twin flush setting, wash basin of min dimensions 510mm x 400mm with all necessary fittings including Angle cock, Connection pipe, waste pipe, Spatula Lever basin mixer, Wall mounted 600mm long, Wall mounted grab bar 600 mm long and wall mounted hinged rail 750 x 750, Health Faucet with angle cock. Recommended Makes : CERA , Hindware, Jaguar or equivalent . 90 Plumbing 91 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall32 mm nominal outer dia pipes 92 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall40 mm nominal outer dia pipes 93 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall50 mm nominal outer dia pipes 94 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes 95 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes 96 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore 97 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore 98 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore 99 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore 100 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall 101 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall 102 Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall 103 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow 104 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee 105 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63x50 mm dia Reducer 106 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 107 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 6Kgf/cm2 108 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2 109 Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall 110 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend 111 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee 112 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl 113 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia End cap 114 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow 115 Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall 116 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend 117 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee 118 Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl 119 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap 120 Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow 121 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer 122 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore 123 Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 124 Yard Plumbing 125 Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2 126 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling 127 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):With common burnt clay F.P.S ( non modular) bricks of class designation 7.5 128 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Single pushfit Coupler110 mm 129 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionBend 87.50110 mm bend 130 Tile and Granite work 131 Providing and laying Matt Finished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 1200 x 600 mm. 132 Providing and laying Matt finished Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, ofapproved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 1200x600 mm 133 Providing and laying Anti Skid matt vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. 134 Providing and laying premium vitrified bathroom wall tile in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. 135 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm 136 Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining ( veneer work), backing filled with a grout of 12 mm thick average in cement mortar 1:3 ( 1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 ( 1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade ( To be secured to the backing by means of cramps, which shall be paid for separately).Area of slab over 0.50 sqm 137 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade. Area of slab over 0.50 sqm 138 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 139 Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work 140 Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 141 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 142 Providing and fixing 12 mm thick gang saw cut, mat /rough finished granite, machine cut for steps, ramps or inclined plate form with raking and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 143 Structural steel 144 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 145 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 146 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 147 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 148 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 149 False ceiling 150 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board 151 Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit. 152 Rainwater Harvesting ,Fire Tank,Septic Tank 153 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock 154 Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock 155 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 156 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 157 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level 158 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 159 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm 160 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm. 161 Supplying and fixing C.I with frame for manholes: 600mm x 600mm ( heavy duty) the weight of the cover and frame shall not be less than 208 kg 162 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 163 Providing and placing on terrace (at all floor levels) Stainless Steel 304as per IS 5522:1992 of capacity 5000 Litreswith suitable fixing arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 164 Providing and fixing of Fire Rated door 1200x2100mm- Hollow metal fire doors at all levels from ISO 9001-2015 certified Manufacturer. Fire door should be as per NFPA 80 and NFPA 252. All fire doors should be tested at UL for 120 minutes and should pass both UL10B and UL10C. Doors shall be made from pressed galvanized steel confirming to IS277 as per following specification.Frame:Door frame shall be single rebate grooved profile of size 125 x 55 mm made out of 1.6 mm (16 gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self-tabs. Frames to have in build grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate ANSI UL labeled hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff and the gaps shall be sealed with silicon sealant.Shutter: Door leaf shall be 46 mm thick fully flush double skin door without vision lite. Door leaf shall be manufactured from 1.2 mm (18 gauge) minimum thick galvanized steel sheet.The infill material shall be resin bonded honeycomb core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI standard. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf.Door and frames shall be finished Pure Polyester Powder coated and shall have passed minimum 500 hours of salt spray test.Vision glass: The glass shall be 5mm clear fire rated glass of equal rating and not exceeding size of 114 sq. inches.Door Hardware: Stainless steel Ball bearing Hinges 3 Nos, Minimum 90Kg hydraulic surface applied rack and pinion door closers, Mortice Sash Lock with cylinder. One Side Handle and Other Side with 2 point Panic Bar. 165 Road Work 166 Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30 167 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. 168 Water proofing 169 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 170 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) 171 Landscaping 172 Supplying of Flowering Shrubs (Heliconiya st. Vincent red, Ixora bush, Cana durf etc..) 173 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removalof unsaverieable material?s as per direction of officer in charge (including cast of plant & water )Cost of plantation per trees plants (for 100 nos.=427.45/100) 174 Providing and Laying Landscaping of outdoor area with buffalo grass and small plants with all necessary levelling and filling as required. 175 Signage 176 Providing and fixing in position the signage board made out of 3 mm opaque PVC foam board of computerised cut, PVC non reflective self adhesive vinyl painted foam board of required size and colour. 177 Providing and fixing non lit Signages made of CNC Cut Stainless Steel projected letters and fixing it at site with all necessary fitting arrangements and accessories as per the design and requirement on instructions of the engineer in charge. 178 Furniture 179 Two tiered reagent racks (MS with powder coating) with granite top of 150 mm depth for side workbenches. The two tier should be placed at a minimum spacing of 300 mm. The item should be in compliance with IS 4209 (2013), NABL etc. The Length should be customized as per lab workbench and vertical posts must be placed at appropriate spacing. 180 Supply and Installation of Sink Module with SinkEach sink module should have a minimum dimension of 900 mm (L) x 900 mm (W) x 900 mm (H) and made of MS as per IS 1730 shall be designed with a single cabinet (with 2 shutter, SS304 hinges for easy and noiseless opening and closing mechanism). This module should include a sink made of 5 mm thick polypropylene with black color body. Minimum Dimension of the sink: 450 mm (L) x 600 mm (W). Sink should include PVC tap connection-15mm diameter (Goose neck type), grating etc. The sink module shall be portable and provided with 18mm thick granite table top (with cut out for providing sink). Item to be inclusive of all necessary fitting arrangement.The item should be in compliance with IS 4209 (2013), NABL, WHO etc. 181 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 750 mm D 182 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 890mm D 183 Supply, Installation, Testing and Commissioning of Eye wash with Brass inject mould with epoxy powder coated body with auto released Valve and cup shaped water dispenser with min 1/2 HP power pressure booster pump 184 Counter Height Stools :Supply and erection of counter height stools ( bar stools ) of following specifications : Revolving adjustable Chrome plated steel body chairs with resistance to the corrosion. Cushion Seat with Lift mechanism for Adjustment of height. Minimum height 750mm before expansion. Medium Back rest and arm rest. Item shall be of reputed make. 185 Office Chair: Non-revolving executive chair with fixed armrest providing natural resting for arms. Seat with PU cutted foam backed fabric, back rest with mesh type fabric, Upholstery: Heavy duty rubber backed fabric in BLACK ( Size -55x60 cm) 186 Executive Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 187 Revolving Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 188 Cabinet/Wardrobe: Providing and fixing Cabinet/Wardrobe unit with 18 mm thick Multi wood board with one side decorative and other side balancing lamination. cupboard shutters edge to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickel plated bright finishing M.S. piano hinges conforming to IS:3818 marked with fixing chromium plated brass 50 mm cupboard or wardrobe knobs, special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. Depth of shelves to be 300-600mm and shelves to be fix with proper support and bracket holders. as per layout drawing approved by Engineer in charge. Make laminate: Greenlam/ Merino / Century. Only front elevation will be measured. 189 Supply and erection of Airport type 3 seater waiting chair with powder coated chromium finish having minimum dimensions 1675mm length X 710mm width X 775mm total height and 400mm seat height . Seat: High quality cold rolled 1.2mm thick steel perforated sheet pressed and welded to form the shape. Arm & Leg: High quality 1.2mm thick MS Tube / Sheet . Cross bar: High quality cold rolled 2mm thick steel sheet pressed and welded to form the shape. 190 Table of size Min 2300x600mm Made of minimum 18mm BWR ISI (303 Grade) plywood (Century, Greenply, Fineply or equivalent). On top and all sides with 1mm thick hot press (3M or Henkel) laminates (Brand MERINO, Associates or equivalent) of approved colour and pattern as per the design. The table is provided with 1 drawer, 1 Storage, 1 key board locks, handles, mini fix, dowels and screws. Exposed edges to be finished with 0.8 mm edge band as per specified colour. 191 Supply of wooden table with one drawer and Cupboard unit made of hard wood varnishing/painting all complete. Size: 1200x600x750mm 192 Providing & supply of Conference Table with executive chair of 13 Pax with the following specifications.Table top size :3600 x 1200mm. Table Tops –made of 25mm thick MDF with waterfall top edges finished in PVC Membrane using unique wrap around technology for better aesthetics & long lasting use. Under structure – Legs made of 25 mm thick standard Black matt colour post formed panels interconnected with 18mm thick standard Black matt colour pre-laminated modesty panels, with height adjustable levelers to take care of uneven floors. Wire Management & Concealed wire management to take care of basic wiring requirements both horizontally & vertically. For closed configurations, liftable top cover, made of 12mm MDF finished in PVC Membrane, is provided to access the horizontal wire carrier. Vertical wire management is through flexible vertical wire manager, popup grommet with power & RJ45 Socket. Designed for Flexibility through modular Construction, PVC Membrane Finish Tops for seamless surface, Post formed Legs for safe use, Provision for easy wire management, Upgradeable / reconfigurable for future needs. 13 Nos Revolving adjustable type Medium height Back Office Chair with arm rest with back tilt and swivel mechanism constructed out of mild steel and high quality plastic. 193 Supply of wooded Chairs with armrest of Hard Wood Plank Seat and Reaper Back. 194 Supply of Wooden Bench and Desk made up of Mahagani of minimum size - Bench Size :1 83x30X46cm Desk Size :183x41x75 cm 195 Supply and installation of steel podium made of SS304 with min dimensions 500mm X 450 mm X 1200mm and having a sloped top surface, and having a decorative/ plain front face all made of SS 304 as per the design and approvals of the architect/ Engineer - In - Charge 196 Wiring-General Electrical work 197 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 198 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 199 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire 200 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 201 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 202 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 6 Sq.mm + 1 x 6 sq.mm earth wire 203 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 204 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 205 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 16 sq. mm + 1 X 6 sq. mm earth wire 206 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 207 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 208 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 209 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm 210 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm 211 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm 212 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair 213 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 214 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 215 Fixtures 216 Supply and Fixing suitable size modular GI box with cover in front on and providing and fixing 1 no RJ 45 including connections as required. 217 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). 218 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 219 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet 220 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) 221 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet 222 Supply and Installation of surface/recess mounted LED 2x2 luminaire with CRCA housing suitable with fully diffused diffuser for general lighting. The luminaire should have CRI > 80 and CCT of both 6500K/5700K, Cool White Light. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3700 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 36 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro or equivalent 223 Supply, conveyance and Installation of compact, 2 feet,10-15W,LED tube light with high lumen giving soft glare free light including all required mounting accessories, frames complete. (Philips/WIPRO/Havells or equivalent) 224 Supply, Installation of surface mounted LED Tubelight. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 30 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 25k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make - Philips, Crompton, Wipro, Havells 225 Supply, Installation of surface/recess mounted LED Round/Square luminaire with CRCA housing suitable with fully diffused diffuser for general lighting in office areas. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 110 lumen/watt and Minimum system wattage of 10 -15 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro 226 Supply, conveyance and Installation of compact 10-15W LED Bulkhead Light giving soft glare free, Cool White light & complete with electronic driver including all required mounting accessories, frames, complete ( Make: Philips/WIPRO/Havells or equivalent) 227 Supply, Installation, Testing and Commissioning of 1400 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 228 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 229 Supplying, conveyance and Installation of 150-250 mm sweep,1350 rpm, 3 - 5 blade BLDC Exhaust Fan including frames and all mounting accessories complete.Recommended Make: Atomberg Efficio/Crompton Brisk Air 230 Supplying, conveyance and Installation of BLDC Type Wall Fan having 3 blade, 400 mm sweep, Speed 1350 rpm, Air Delivery 70 CMM minimum, Wall Mount Fan including frames and all mounting accessories complete. Recommended Make: Atomberg Renesa/V-Guard ENVIRO WF BLDC/Havells Platina 231 Supply, Installation, Testing and Commissioning of 450 mm sweep, 900 rpm heavy duty exhaust fan with louver in existing opening including making good the hole to suite the size of above fan complete with connections using 3 core 1.5sqmm multi core pvc sheathed copper conductor cable etc as required. 232 SITC of skirting light fitting with white LED 3 module along with suitable size modular metal box with inner and outer plates with all accessories. 233 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). 234 Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. lCD 235 Supply and installation of 2 Nos. 4 ft MS powder-coated hanging rods for tube lights, including supply and laying of 1.5 sqmm copper PVC insulated FRLS wire (3 runs: Phase, Neutral, Earth), necessary hardware (ceiling clamps, saddles, junction box, connectors), complete mounting, terminations, testing, and labour charges — complete in all respects. 236 Network and CCTV System 237 Supply of 16 ports Network Switch, Rack-mountable 10/100/1000 Mbps, Switching capacity 35.7 Mbps Features: Flow control, Layer 2 switching, auto-negotiation, auto- uplink (auto MDI/MDI-X), Weighted Round Robin (WRR) queuing, Quality of Service (QoS) Power: AC 120/230 V (50/60 Hz) complete. Make D-Link/TP Link/Cisco or equivalent 238 Supply Installation Testing and Commissioning of 32 channel embedded Linux NVR (Network Video Recorder), must connect 32 channel IP cameras, Should support min 2 SATA HDD and each should support Min 2TB and must record video simultaneously, (Recording Type: Continuous, Motion Detection, Alarm, Smart Event, Event Motion Detection, Alarm, Smart Event), Video Compression H.265(HEVC)/H.264+/H.264, 2 Year Warranty, Image quality should be maintained throughout the warranty period. Make: CP Plus/Hikivision/Dahua or equivalent 239 Network Switch for CCTV. 16 Port PoE Switch 1000BASE-T Copper Ethernet PoE+ connections, 10M/100M/1G RJ-45 copper ports, 1000BASE-X Fiber SFP ports, 16 port Auto sensing 10/100/1000 Mbps PoE, minimum CPU memory 512 MB with 2 SFP/combo ports, Energy Efficient Ethernet (IEEE 802.3az) Make: CP Plus/Netgear or equivalent 240 Supply, Conveyance and Installing of 2MP IP Dome/Bullet Camera having Progressive Scan True Day and Night Colour IR Camera having effective pixel of 2 MP, Video frame rate of 2MP @30FPS, Minimum illumination of 0.01 [email protected], 0 lux@IR On, 20 M IR Range, 24 IR LED, AWB, AGC, BLC, 2D Noise reduction, with 3.6mm board lense, 12 VDC, PoE IP67 rated weatherproof performance. 1 year warranty. Make: Bosch/CP Plus/Honeywell or equivalent 241 Supply and fixing of 6U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete 242 Supply Installation Testing & Commissioning of 16 Port Loaded Cat 6 - U/UTP Modular Toolless Patch Panel having a metal structure enabling them to be durably fixed to the uprights of the 19 chassis. Include rear cable manager to hold cables without need for cable ties. The termination of I/0s shall be without any manual crimping tools. 243 Supply and fixing of 4U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete. 244 Supply and connecting 2 meter long CAT6 cable Patch cord having RJ45 connectors crimped at both ends, to the existing outlets as required. Make: D-Link/TP-Link or equivalent 245 Supply and Installation of LED Color display of minimum 32 inch screen, complete, UHD display Make: LG/Samsung/Panasonic or equivalent. 246 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable 247 Supply, Installation and Integration of Dual Band WiFi Access Point on false ceiling along with accessories, having Fast Wireless Speed, simultaneous 2.4GHz 300Mbps and 5GHz, 867Mbps Dual Band connections for 1.2Gbps of total available bandwidth, Superior Coverage of Four Fixed External antennas provide stable wireless connections and optimal coverage, App Control, Interface of 1× 10/100 Mbps WAN Port and 4× 10/100 Mbps LAN Ports having Working Modes (Router Mode / Access Point Mode). Make: TP-Link/Netgear/DLink or equivalent 248 UPS 249 Supply, Installation, Testing and Commissioning of True on-line Double Conversion 10 KVA UPS system with 3:3 Crest Factor Three Phase Input Three Phase Output. Inversion shall be Microprocessor controlled with instantaneous sine wave Control using IGBT. UPS shall have standard display features, alarms, safeties, etc Input Voltage range : a) Phase – Three Phase with ground b)Voltage range 190 VAC – 470 VAC c)Input Frequency :50/60 Hz d)Power Factor : 0.95 or above e)THD : less than 5% with full load Bypass f) Voltage Range – 200VAC – 240 VAC ) Frequency range – 45-55 Hz/55-65 Hz Output Voltage Range h)Voltage Range – 200VAC – 240 VAC i)Frequency range – 50/60 Hz j)Voltage distortion – linear load <= 2% k)Voltage distortion – nonlinear load <= 5% l)Output waveform – pure sinewave m) Crest Factor – 3:1 Minimum Back up time : Continuous 30 Minutes at full load Rectifier shall be Full wave Type (Shall fully meet the specified input power requirements) Battery Type: Sealed Lead Acid Maintenance Free DC Voltage : 96V DC System, Battery Nos and capacity shall be designed for optimum storage space. Installation &Commissioning Required Breakers also needs to be provided in input and output side for the UPS. Make: Liebert Vertiv/APC by Schneider/Numeric by Legrand 250 Cable Trays 251 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.375 mm width X 50 mm depth X 2.0 mm thickness 252 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness 253 Fan Clamp 254 Providing and fixing 16 mm S.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 255 DB and Switchgear 256 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) 257 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 258 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 259 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door 260 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 261 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural 262 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole 263 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 264 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 265 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps 266 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 267 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 268 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts C curve TP MCB complete with connections, testing and commissioning etc. as required. 269 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 270 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral 271 Earthing and Lightning Arrestor 272 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re- filling etc. as required. 273 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 274 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. 275 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 276 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 277 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 278 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 279 Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. 280 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube,having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 281 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 282 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 283 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 284 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG) 285 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) 286 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG) 287 Street Lights 288 Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 289 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps 290 Water Purifier 291 Supply and Installation of Water Purifier having Multi-Stage Filtration: RO (Reverse Osmosis), UV (Ultraviolet), UF (Ultrafiltration), Storage Capacity: 7-9 Liters, Purification Features: RO: Removes dissolved impurities, heavy metals, and salts.UV: Kills bacteria, viruses, and other microorganisms. UF: Filters out fine particles and microorganisms. Mineral Booster: Adds essential minerals to enhance water taste.TDS Controller: Adjusts Total Dissolved Solids for taste preference. ActiveCopper: Infuses copper ions into the water for added health benefits.Aqua Taste Booster: Enhances the taste and maintains optimum pH level. In-Tank UV Disinfection: Keeps stored water pure.Smart Display/Indicators: Alerts for filter change, UV fail, water level, and service needs. Super Fine Sediment Filter: Removes fine and coarse particulate impurities. Water Level Indicator: Monitors the purified water level in the storage tank. Make: Aquaguard Aura 7L/ Bluestar Aristo 7L/Kent Grand Plus ZWW 9-Litre/ LG 8L 292 LT Cabling and Termination 293 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 294 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 295 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp 296 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 297 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp 298 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm 299 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm) 300 Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 400 sq mm 301 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm) 302 LT Panels 303 Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work. General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall befl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 400A 3kA 4 Pole MCCB - 1no Ics = 100% Icu rating Digital Voltmeter 0- 500V with selector switch & Digital ammeter (0-400A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 400A. Out going : 250A ,50kA 4 Pole MCCB - 2no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 304 Lift panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 40A ,16-25kA TP MCB - 6 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list.Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 305 Sub Panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required. Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch &Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 32A ,16-25kA 4 Pole MCCB - 4 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 306 SSB2- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 250A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-250A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 250A. Out going : 1) 63A ,16-25kA 4 Pole MCCB - 8 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 307 Transformer 308 Supply , Installation, Testing and commissioning of 500 kVA outdoor unitized substation with an 11kV/433V dry-type cast resin transformer and a 630A VCB typically includes a compact prefabricated design conforming to IEC62271-202 standards, offering IP53/IP23 protection, and featuring compartmentalized construction to prevent accidental entry into energized areas. The substation is designed to withstand electrical impulses, thermal, and dynamic stresses, ensuring reliable and robust performance with low power loss and noise levels. The installation involves placing the substation on a prepared concrete plinth, connecting high-tension (HT) and low-tension (LT) cables, and ensuring proper earthing and safety measures. The commissioning process includes testing the transformer, switchgear, and protection systems to verify operational integrity. Make: Unipower/Intrans/Voltamp 309 MSB and APFC Panel 310 Supplying, installation, testing & commissioning of cubical type MAIN SWITCH BOARD suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having front surface area 6 sq.mtr (Approx.) fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 630 Amp capacity extensible type TPN aluminium alloy bus bars of height conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :- Interlocking:Electrical through advance contacts in MCCB/ ACB’s (incomers & bus couplers) and mechanical (castel key) interlocking should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possibility of accidentally approaching two supplies at one bus section.Interlocking b(I) Incoming : 2 Nos 800 Amps (DG and MAINS) each four pole ACB of fault breaking capacity 50 KA (Ics=Icu upto 433 V manually operated, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS 1397- 2 : 1993 as amended up-to-date complete with following accessories for each MCCB(a) Independent manual spring closing mechanism- 1 No.(b) Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection- 1 set.(c) Digital* type Voltmeter (0-500 V), with selector switch & back up HRC fuses/MCBs-1 set. (d) Digital* type Ammeter (0-.600 Amp), with selector switch and one set of 3 nos. CT’s of ratio. 800/5A Class I accuracy and 15 VA burden- 1set. (Ratio to be fi lled up).(e) 3 Nos. Phase indication LED lamps with 2 Amp back up HRC fuse, breaker ‘ON’ indicating light with 2 A HRC fuse, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.(f) Shunt trip coil 220 V A.C. (II) Bus Bars :TPN aluminium bus bars of minimum of 800 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec (II) Outgoing :(1) (a) 4 Nos. 250 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 250/5 Amps Nos. (c) Digital* type ammeter (0- 400 Ap) with selector switch set. (2) (a) 1 Nos. 200 Amp4 Pole MCCB for (Ics = 35 kA upto 433 V) (b) CT’s of ratio 200/5 Amps set (c) Digital* type ammeter (0- 250 Amp) with selector switch set. (3) 3 Nos 160 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 160/5 Amps set (c) Digital* type ammeter (0- 200 Amp) with selector switch set. The switchgears/measuring instruments shall be as per the Choice of the Engineer in charge. The panel shall be mounted on required structural steel supports and frames for mounting, the price quoted shall be inclusive of the same. The panel shall have suitable provision for connecting to the incoming cables of 3R x 400 sqmm XLPE Aluminium cables and shall be provided with necessary earth leakage relays as per the Inspectorate Norms. The panel shall be as per the IS standards and shall conform to all norms of EB/Inspectorate/CEA. Make of Switchgear : ABB/L & T/Schneider Electric/Siemens/Legrand 311 Design, Manufacture, Supply, Installation, Testing and Commissioning of Automatic Power correction Panel having Incomer: 250A, TPN MCCB, Digital Multifunction meter for V,A,F,PF With CTs CL:1 with RYB Indication lamps-1 Set 250A Aluminium bus bar with heat shrinkable insulation sleeves-1 set, Intelligent power factor controller with control MCBs etc. complete The panel shall comprise of suitable combination of capacitor banks upto a total of 100 kVAR and shall be designed as per the standards of Electrical Inspectorate/CEA. 312 DG and AMF Panel 313 Supply, Installing, Testing and Commissioning of & Silent Type& Diesel Generating set having CPCB IV+ acoustic enclosure having Prime Power Rating of 500 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor and consisting of the followings: Diesel engine radiator cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories. Engine mounted Instrument Panel fitted with and having digital display and necessary indication coupled to Synchronous alternator rated at 500 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor. Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. Daily service fuel tank of 440-460 litres capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. Dry exhaust manifold with hospital exhaust silencer and catalytic convertor. 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (lead acid type) as required as per specifications. Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications. 314 Design, Fabricating, Supply, Installing, Testing & Commissioning of automatic mains failure control including auto by-pass panel, suitable for 500 KVA silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH & provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required, all complete and inter locking including the following: (a) 1 Nos. 630 Amp., 50 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50-100% having adjustable OL & SC. Set at 350A (b) Auto/Manual/Test/Off selector switch (c) 2 Nos. over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay. (d) 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering(e) Energy analyser unit to indicate current voltage frequency power factor and KWH(f) Indicating lamps for load on mains and load on set(g) Fuse for instruments(h) Battery charger, complete with transformer/ rectifi er, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.(i) Main supply failure monitor(j) Supply failure timer(k) Restoration timer(l) Control unit with three impulse automatic engine start/stop and failure to start lockout.(m) Impulse counter with locking and reset facility.(n) ON/OFF/Control circuit switch with indicator(o) Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning. AMF Panel shall be connected to Main Switch Board incomer with necessary interlocking arrangement to prevent simultaneous switching on of power supplies. All integration between Main Switchboard and AMF Panel is under contractor scope. 315 HT Cable 316 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium powercable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 300 sq mm 317 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm 318 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm 319 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm 320 Air Conditioning Works 321 Supply, Installation, testing and commissioning of 3 x 3 Cassette type Air Conditioner of following capacity and specifications: Consisting of ceiling-mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of energy-efficient suitable rotary compressor for operation on single-phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation, with R-32/R-410A or equivalent refrigerant and fixing of room (fan coil) unit on ceiling, standard 5 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1 dia drain PVC pipe with insulation up to 5 m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. (Make: Voltas, Blue Star, Daikin, Hitachi, Carrier or equivalent). Minimum 2 TR 3 Star rated (inverter type AC) as per BEE 322 Supplying additional copper piping of required size and connecting the same to the available piping and extension of the same through 100mm PVC duct inside false ceiling. 323 Electrical Dismantling Works 324 Dismantling of existing outdoor transformer and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 325 Dismantling of existing DG set 100 kVA, AMF panel etc and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 326 Electrical Works- Fire 327 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm 328 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 329 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 330 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 331 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) 332 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) 333 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm) 334 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 335 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 336 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 337 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 338 First Aid Hose reel &Wet Riser system 339 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.a.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585b.20 mm nominal internal dia gun metal globe valve & nozzle. c.Drum and brackets for fixing the equipmets on wall.d.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m 340 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 341 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way-100 mm dia M.S. Pipe 342 Supply and fixing of Air release valve SS body of 25 mm dia (UL Listed). 343 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 344 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 345 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) 346 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304) 347 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel 348 Hose Box - Supply, Installation, Testing and Commissioning of Hose Box -Double door - (cabinet) to accommodate Two pieces of 63 mm dia fire hose along with one pair of 63 mm dia male & female couplings and one branch pipe. The cabinet is made of MS sheet, painted in approved red colour with glass fronted hinged doors and lock &key (UL Listed). 349 Supply and Installation of Fire Brigade Draw-out Collecting head of CI Body having gunmetal 63mm dia instantaneous male draw out confirming to IS:903 suitable to fit on 100mm dia pipe with necessary flanges, rubber gasket, nut & bolts and other items. 350 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 351 Fire extinguishers 352 Supply &installation of ISI ABC type fire extinguisher of 4 kgs. Make SAFEX/ MINIMAX / CEASEFIRE or equivalent(UL Listed) 353 Supply &installation of CO2 type fire extinguisher of 4.5 kgs. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 354 Supply & installation of water mist type fire extinguisher of 9 liters. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 355 Supplying & Installing of Clean agent based automatic modular fire extinguisher (ceiling mounted) suitable for A,B,C class fires & electrical fires, Capacity- 5Kg 356 Supplying & Installing of Mechanical Foam (Stored Pressure) Type fire extinguisher of 9L capacity with mounting clamp. ISI approved. Make : SAFEX/MINIMAX/CEASEFIRE or equivalent 357 Fire Pumps & Fire Panel 358 Electric driven Main Fire Pump: Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.1620 lpm at 56 m Head 359 Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads. 1620 lpm at 56 m Head 360 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)a.Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325.c. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. As required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 56 m Head 361 Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector switch & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING (Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.Jockey Pump63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROLControl for diesel engine comprising - Automatic/Manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller.Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification 362 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 150mm 363 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 80mm 364 Supply and Installation of 12V DC, 200Ah maintenace free battery suitable for Diesel Engine driven fire pump operation with required connect cable set, battery stand. 365 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 100mm 366 Signages 367 Supply and fixing in position Exit Signages photo luminescent type with indication arrows and letters Exit/Fire Exit/ Staircase/FIRE/Fire Station/Fire Fighting Equipment/Fire Duct/ Fire Extinguisher/ Floor/Fire Command Centre/Fire Pump Room/ No Smoking / Danger/ Call point / Sounder Identification Numbers (Ground/ 1st/2nd)/ In case of the fire do not use lift, use stairs and other mandatory signages recommended by Fire Departments having dimension 30 cm x 15 cm complete inculding fixing mechanism. 368 Supplying and Installing in position the signages approved by Kerala state fire service - of minimum size 1ft x 1.5ft made out of PVC rigid sheet 3mm thick with computer cut PVC non- reflective self adhesive imported vinyl painted on the front of PVC rigid sheet complete with wall mounting arrangements with mirror screws. with lettering- ASSEMBLY AREA 369 Signboards: Supply and Installation of Fire Escape Plan with fire fighting equipment location, exit in A3 Foam sheet with plastic lamination with necessory accessories to fix it on wall. 370 Supply and fixing in position & Fire Order& signage in suitable size made of high quality PVC foam sheet with photo luminescent lamination to make it glow automatically in the dark, with suitable arrangement to fix it on wall. 371 Supplying & fixing in position Assembly Point sigange in suitable size on aluminium composite panel with suitable stand to fix it on open area outside building. Assembly Point 372 Terrace pump 373 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)a.Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325.c. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head 374 Design, Supply, Installation, Testing, and Commissioning of an Automatic Terrace Fire Pump Panel, including:- IP54-rated enclosure with powder-coated CRCA sheet steel.- 32A 16kA MCCB, 15 HP-rated pump 3P contactor, overload relay, and pressure switch for automatic pump operation.- Auto/Manual selector switch, START/STOP push buttons, hooter, timer, and protection features (dry-run, phase failure, etc.).- Indicators (Power ON, Pump Running, Fault, Low Pressure), meters (Voltmeter, Ammeter with selector switches).- Copper wiring, termination, and provision for cable glands.- Installation, onsite calibration, and full functional testing for pressure-based automation. 375 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 376 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 377 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 378 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 379 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100mm dia 380 Pressure Guage-Supply, Installation, Testing and Commissioning of pressure guage, 4 & dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 381 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations (UL Listed).20 mm dia Make : Kartar/ Atom 382 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 383 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 384 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 385 Above Ground Piping 386 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia 387 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia 388 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia 389 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :250 mm dia (wall thickness 6.3 mm) 390 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150 mm dia 391 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :200 mm dia (wall thickness 6.3 mm) 392 Supply and Installation of 80mm dia M.S. &C& Class Diesel Engine exhaust pipe duly insulated with 50mm thick Glass wool with 1mm thick aluminium sheet cladding with bellows, flexible joint, necessary support, making hole in brick wall for pipe installation.Pipe dia 80mm 393 Underground piping 394 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 150 mm. Make - TATA / JINDAL 395 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 200 mm. Make - TATA / JINDAL 396 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (1m below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 100 mm. Make - TATA / JINDAL 397 Valves, measuring devices & switches 398 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required:200mm dia 399 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required80 mm dia 400 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 401 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required150 mm dia 402 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80mm dia 403 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150mm dia 404 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.150mm dia 405 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. 406 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 407 Pressure Gauge-Supply, Installation, Testing and Commissioning of pressure gauge, 4 dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 408 Supply and fixing of Air release valve Brass body of 25 mm dia (UL Listed) following IS standards, with required pressure rated. 409 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 410 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 411 MOEFA system, Automatic Detection & Fire Alarm System 412 Supplying, installing, testing and commissioning approved make Microprocessor based Multi-loop, Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 trouble events including1000 alarm log history events, Self Programmable alphanumeric keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 Loops. Each loop shall have a capacity of minimum 125 detectors & 125 other devices exculding 20% spare. The panel shall work in degrade mode in case of CPU failure, Products not having this feature may offer Redundant CPU. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition with the charging capacity of 200AH. The panel shall be capable of self programing without any dependancy on dongle or programming software. Quoted rate shall include supply of necessary software & hardware for progamming the panel with all necessary licence. Panel shall have Modbus over IP protocol for future integration with BMS. However, for present arrangement FA system will be standalone with 24x7 monitoring. The panel shall be capable of connecting to the cloud platform/solution. Complied to meet UL864, 10th Edition 6 Loop Networkable Addressable Fire Alarm Control Panel(Make: Honeywell or Equivalent) 413 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 414 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 415 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 416 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. 417 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 418 Supplying, Installation, testing & commissioning of external power supply unit provides regulated and filtered 24 VDC power for hooter operation.Battery backup with built in charging. 419 CABLING & WIRING Supplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 420 Miscellaneous 421 Preparation of initial and final drawings, submission to Panchayath, Municipality, KSEB, Electrical Inspectorate, Kerala Water Authority, State Pollution Control board, Fire Department, Factories and Boilers and other agencies if any for getting approval, sanction and No Objection Certificate for building permit and completion from Fire Department and other department. Quoted rate shall be excluding statutory fee (All statutory fees shall be borne by Client-actual statutory fees shall be reimbursed on submission of original bill/challans from authorities).
Contract Date: Jul 17, 2025 Contract Value : 11.48 Crore
Boards / Undertakings / PSU No of Bidders 1
27.
Public Administrative Department #10363312 Price Bid
Tender For Construction Of New Office Building Of Municipal Board Nawa - CIVIL WORKSClearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 2 Earth work in excavation by mechanical means (Hydraulic Excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils 3 Add extra for foundation/trenches/drains for every additional lift of 1.5 Mtr. or part thereof inAll kinds of soil 4 Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. 5 Supplying chemical emulsionin sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20% 6 Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion) . 7 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). (UNDER FLOOR) 8 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). (FLOOR UNDER FOOTING AND FOUNDATIONS 9 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M25 grade Design Mix by usingmin 410 kg of cement per Cum . 10 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M25 grade Design Mix by usingmin 410 kg of cement per Cum . 11 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix 12 Providing and laying in position Ready mix concrete manufactured in fullyautomatic Batching Plant andtransported to site intransit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge.All works upto floor V floor. Design Mix by usingM-25 grade concrete by using min 410 kg of cement per Cum 13 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 14 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : Walls (any thickness) including attached pilasters,buttressesplinthandstring course. 15 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 16 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Columns, pillars, posts and struts etc. 17 Add extra for additional height in centring, shutteringwhere ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at alllevels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan are is to be measured) 18 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.(Original producers who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Thermo-mechanically Treated bars (Conforming of relevent IS code) 19 Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Grade 304 20 Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m) fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.Hot finished welded type tubes. 21 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). 22 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) 23 Half Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 75 in superstructure above plinth level upto floor V level in. Cement mortar 1 : 6 (1 cement : 6 coarse sand) 24 Add extra providingand placing in position 2 Nos. ,6mm Ø M.S. barat every thirdcourse of half brick masonry 25 Providing and fixing Stone jali 40mm thick Red/Pink sand stone throughoutin cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali patterns to be cut square to jali slab without any chamfers etc: 26 Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 20mm thick . 27 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) 28 Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth completeNew Plastered Surface (three or more coats) 29 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect 30 Finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specificationsincluding primer coat and protecting coat including scaffolding and safety provisionTrowel Finish av. thickness 1500 to 2000 microns. 31 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade :Two or more coats on new work 32 Making of drip course (Tapka) in cement sand mortar 1:6 width upto 40 mmand 10 mm thick as per approved design 33 Making grooves as per design in plaster 10mm to 20mm wide. 34 P & F 1st quality Heavy Duty Vitrified Double Charged tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete.Size 600X600mm 35 size600 mm X 1200mm 36 P & F 1st quality Heavy Duty Vitrified glazed MAT tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. size600 mm X 600 mm 37 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 38 Extraforusingsize above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finishedtiles in place of 300mm x 300mm size. 39 Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm 40 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete For area of each slab upto 2001Sqcm 41 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. 42 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) Medium shade using approximately 50% white cement and 50% ordinary cement. 43 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.South Red1501 Cm2 to 3600 Cm2 Tiles 44 Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite/Kota Stone Work Full Edge moulding 45 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete 46 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete 47 Providing and fixing 1st quality standard Marble printed/ Granite Shade or Light/dark shad glazed tiles confirming to IS : 13753 & IS :15622 of size 300mm x 600mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 48 Providing and fixing wall panelling using soft wood frame of size 50x25mm @600 mm c/c in both directions duly treated with anti-termite treatment making grooves painting of grooves specification and drawing using : ISI 9 mm teak ply one side BWR 49 Providing and fixing pressed steel door frames confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applyinga coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4(M15 grade) complete as directed by Engineer-in-charge : Profile E 50 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A: 35 mm thick . Commercial Veneer both side 51 Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. 52 Providing & Fixing mica of approved make for inner/outer side of shutters with fevicol & nails completeas per approved by engineer in charge. 0.8mm thick mica 53 Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint 54 Providing and fixing fully panelled /partly panelleddouble leaf shutters frame for windows and ventilators as per approved design and drawings with approved steel fittings as per Annexure ‘A’ and width of styles, bottom and top rails 75mm including intermediate rails 50mm wide, beading of 25mm x 15mm size on both faces : 35 mm thickGhana wood grade I 55 Providing and fixing bright finished Mortice lock of approved make Godrej or equivalent withpair ofCP handles for doors with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge. 56 Providing and fixing of uPVC casement fixed windows or ventilators manufactured in ISO 9001:2000 & 14001:2004 certified company. Frame : Made from the Extruded uPVC Window Profile Section of size 60 x 60mm having outer wall thickness of 2.25mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2mm thick G/J/U/O TYPE GI section. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of acCumulated water, if any, to outer side. Fix Mullion made of 76 x 60mm uPVC Profile Section with steel reinforcement shall be provided in windows as per the requirement. Frame shall have ‘O’ type EPDM gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Glazing bead of size 34 x 20mm with ‘K’ & ‘O’ type inner and outer EPDM weather seal gaskets alongwith 5mm thick ISI make plain float glass.All welding joints of frame and shutter shall be cleaned and milled with the CNC mechanism to provide uniform grooved finish on all visible joints. Hardware : Installation at Site : Complete window is to be installed on site with 10 x 100mm fastners with white cap in existing pre-finished wall cut-out cemented to glass level plane at all height & width and silicon glue is applied to fill up the crevices between wall and window frame. Complete in all respect as per the drawing and specifications and direction of engineer-in-charge. (Insert 6mm tougend glass) 57 Providing and fixing of uPVC Sliding windows: Frame Made from the Extruded uPVC Window Profile Section of size 106w x 50h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2 mm thick GI section. Frame shall have three track configuration, two for sliding of window shutter and one for mosquito mesh shutter. Vertical member of frame which bears the sliding shutter load shall have aluminium rail/track for smooth sliding of shutter rollers. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side.Shutter : The shutter of sliding window shall be made of 39w x 69h mm Extruded 3 box multi- chamber uPVC Window Profile Section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5mm thick GI section duly mitered cut & thermal welded at all corners and fitted with uPVC glazing bead of size 22 x 20 mm with inner and outer co-extruded EPDM/TPE-Eweather seal gaskets alongwith 6mm thick ISI make plain float glass. Mesh shuttershall be made of 39w x 69h mm Extruded 3 box multi-chamberUPVC Window profile section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5 mm thick GI section duly mitered cut & thermal welded at all corners and fitted with nylon/polymer mesh and rollers/pully. (Insert 6mm tougend glass) 58 Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately). For fixed portionPowder coating aluminum( minimum thickness of powder coating 50 micron) 59 Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.)With float glass panes of 8 mm thickness 60 Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge.Pre-laminatedparticleboardwithdecorativelaminationononesideandbalancinglaminationonotherside. 61 Grading roof for water proofing treatment withwater proffing compoundCement mortar 1:3 (1 cement : 3 coarse sand) 62 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 63 Making khurras 450 x 450mm with average minimum thickness 50mm cement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1 : 3 and one coat of neat cement, rounding edges and making and finishing the out let complete. 64 Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg ofVG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. 65 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40mm wide and 4mm thick 66 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proffing cement compound @0.253 kg//sqm .This layer will be allowed to air cure for 4 hours. b) Second layer of slurryof cement @ 0.242 kg/sqm mixed with water proffing cement compound @ 0.126 kg/sqm This layer will be allowed to air cure for4 hours followed by water curing for 48 hours. The rates includes preparation of surface treatment & sealing of all joints ,corners,junction with polymer mixed slurry. 67 Providing&fixingprecastcementconcretecoping1:2:4mix50mmthickcompleteas per specification : 68 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-voilet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall confoim to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 5.0mm thick (Wt. 8.4 Kg./Mtr. Sq.) 69 Providing & fixing 12 mm thick tegular edge Glass Fibre Reinforced Gypsum False ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/Sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per 70 Providing and fixing 12.5 mm thick tapered edge gypsum board conforming to IS 2095- Part I at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting. 71 P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor 72 P & F water closet Seat Covers with brass hinges complete :Solid PVC (ISI marked) grade-I White for EWC. 73 P & F White Vitreous China Double Syphonic European W.C. (I.S:2556Mark) with mounted W.V.C. flushing cistern of (IS : 2556 Mark) of 10 litre capacity complete with all necessary internal fittings including cutting and making good the wall and floor. 74 P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: (Size 580x440 mm.) 75 P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall: :PVC with PVCbend as per IS : 7231 . 76 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : Size 630 mm x 500 mm dia for counter top 77 P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers. Size 600 x 450mm x 4 mm thick 78 Stainless Steel Sheet size 125mm dia. Heavy Quality of approved make 79 P & F Liquid Soap Container with brackets complete of approved make: C.P. brass 80 P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. 81 P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls and floors:15 mm dia nominal boreB Class 82 25 mm dia nominal boreB Class 83 P & F G.I. Pipes (External Work) with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc.15 mm dia nominal boreA Class 84 25 mm dia nominal boreA Class 85 50 mm dia nominal boreA Class 86 Concealed pipe in wall including painting with anticorrosive bitumen paint 15 mm dia nominal boreB Class 87 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: C.P. Brass bib cock,15mm nominal bore. 88 P & F Stop Cock(IS :8931 Mark),superior quality & ofapproved make: Brass 400 gm. 15mm nominal bore. 89 P & F Ball Cock (IS :1703 Mark) with Rod& P.V.C. Ball complete : Brass wt.Not less than 400 gm, 20mm. 90 P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc.C.P. Inlet connection 15mm.Brass (IS : 8931 marked) 91 P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :Gun-metal 15mm nominal bore. 92 Gun-metal 25mm nominal bore. 93 Gun-metal 50mm nominal bore. 94 P & F Gun-metal Non-return Valve or Check Valve (IS :Make) of approved make, superior quality:50mm nominal bore. Horizontal 95 P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved desig1000 Lt. Capacity 96 500Lt Capacity 97 Hoisting Charges for each floor :For ITEMS 2.26.1 TO 2.26.4 98 For ITEMS 2.26.5 TO 2.26.8 99 P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant110mm dia 100 160mm dia 101 P&FrigidPVCpipefittings(IS:4985mark)ofapprovedquality/makeincludingjoining the pipe with solvent cement rubber ring and lubricantCoupler (socket)75mm dia 102 110mm dia 103 160 mm dia 104 Reducer 110 X 75 mm110mm dia 105 160 mm dia 106 Plain Tee75mm dia 107 110mm dia 108 160 mm dia 109 Door Y110mm dia 110 160 mm dia 111 Bend 45110mm dia 112 160 mm dia 113 Bend 87 .5110mm dia 114 160 mm dia 115 Door Bend (Top Side110mm dia 116 Vent Cowel110mm dia 117 P- Trap110mm dia 118 Gully trap110mm dia 119 Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.Depth up to 0.5 M 120 Construction of Man hole, in all types of soil, inner size 1.5 x 1.2 M, with 450mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50 mm thick M-15 grade C.C. flooring making channels, 80 mm thick stone slab covering with 40 mm thick M-15 grade C.C.flooring, Ferro Cement cover with frame of 450mm dia, earthwork etc. complete including disposal of surplus earth within 50 mtr. lead as per design :Depth up to 1.5 M 121 Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. Inside size 450 x 450mm depth upto0.5 M Cement cover with frame 122 Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C flooring & over stone slab covering ,80 mm thick slab ,jointing of slab in CM 1:3. Ralthal, Kharanja,50 mm thick stone partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos C.I foot rests of approved design ,two No. 450 mm dia each Ferro cementcover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:- Size 400 x140x150 cm.(for 50 users) 123 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make75 mm dia 124 110 mm dia 125 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /makeCoupler75mm dia 126 110mm dia 127 Bend 87.5 Dg.75mm dia 128 110mm dia 129 Bend 45 Dg.75mm dia 130 110mm dia 131 Door Bend 87.5 Dg.75mm dia 132 110mm dia 133 Single Y75mm dia 134 110mm dia 135 Socket Plug75mm dia 136 110mm dia 137 Pipe Clip75mm dia 138 110mm dia 139 Nahani trap with jali 4110mm dia 140 Vent Cowel 110mm dia 141 P & F W.V.C. (IS: 2556 Mark) Squatting Urinal of standard make complete. Including cutting & making good the floor:Size 450x350mm 142 P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete.Flat Back (small) size 456x355x265mm. 143 Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.:Size 240 Cm. dia outside & 240 Cm. depth 144 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 145 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 Sqm on plan) including disposal ofexcavated earth, lead upto 50m andlift upto 1.5 m , disposed earth to be levelled and neatly dressed : All kinds of soil 146 Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. 147 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. :M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 40mm nominal size). 148 Providing laying, spreading and compacting specified graded crushed stone in sub-base course including premixing the material at OMC in wet mix plant, carriage of mixed material, laying in uniform layers with motor grader, F.E.loader on a prepared surface and compacting with vibratory compactorto achieve the desired density including all material, labour, mach-nery, lighting barricading and maintenance of diversion complete.[MoRTH specification Clause 401] includiong with all lead 149 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand ) including making joints with without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete including painting etc. as per direction of Engineer-incharge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineerin- charge). 150 M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 0.5 to 2.0 MSA for a design life of 20 years.) like city streets, small and medium market roads, low volume roads, utility cuts on arterial roads, etc Category A Denated units to key into each other on four faces zigzagshape as per IRC SP 63:2004 151 Construction oftubewell up to 100m depth and above to accomodate housing and assembly pipe in all types of alluvium strata by rotay drilling method with code of practice for construction and testing of tubewells (IS:2800 (Part-II) : 1991 and IS:2800 (Part-II) :1979 both amended up to date) with supply of bail plug if necessary.The work will not include cost of housing pipe and strainer pipe assembly cost, gravel and development work. Work would be deemedcompleted only after obtaining sound free water during pumping.200 mm nominal bore 152 Diameter 900 mm+C159Construction of Recharge Shaft in filter pit including Earth work Excavation , lifting excavted earth with all lift and 50 m lead and centering & shuttering evenever required. 153 Supply & fixing Pre-cast RCC Rinngs at the mouth of recharge shaft of M20 mix with40 mm thicknessDiameter 900 mm 154 Supply & lowering air line of 25mm dia, G.I. pipe B class having perforation 3 to 5mm size all arrow of G.I. pipe in Zig-Zag fashion & making air vent at top including the cost of Tee-Nipples, Elbow, Socket etc. 155 Supply and lowering vent air pipe 63mm dia rigid PVC pipe(IS 4985) mark class II (4kg per cm2 ) with required all necessary fittings including perforation of 3 to 5 mm size all around the pipe at a distance of 180 to 220mm in zig zag fashion and making air vent at top complete as per direction of Engineer incharge. 156 Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids Size 9 to 12 mm 157 Size 3 to 5 mm 158 Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids. 159 Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985. 200 mm Nominal Bore. 160 Supply and Fixing of Big steel Almirah overall size of916mm (W )x486mm (D )x1980 mm(H) with weldedconstruction. It should have the shelf thickness of 0.7mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high y eld strength) and all other components shall have a thickness of 0.9mm. The Almirah should have a Mazak handle and Three way locking mechanism with Shooting Bolts.It should have a height wise adjustable shelf mounting .Itshould also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated. Plenty of colour options and shelving options shall be available ISimarka brand (Godrej or equivalent) as per approved colour, shape,design,type by engineer in charge. 161 Supply and Fixing of small steelAlmirah overall size of 760mm (W )x455mm (D )x1325 mm(H)with welded construction. It should have the shelf thickness of 0.7 mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high yield strength) and all other components shall have a thickness of 0.9mm. The Almirah should have a 2 Mazak handle and Three way locking mechanism with Shooting Bolts.It should have a height wise adjustable shelf mounting.It should also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated.Plenty of colour options and shelving options shall be available ISimarka brand (Godrej or equivalent) as per approved colour, shape, 162 Providing and supplying Canning Chair of size 455mm X 580mm X880mm. IIshould have wooden canning support at back and bottom supported by steel frame 3 2mm thick,powder coated round pipe with full armwooden handles onsides and other fittings as per direction of enaineer in charae. 163 Providing and supplying Canning Chair of size 455mm X 580mm X880mm. IIshould have wooden canning 4 support at back and bottom supported by steel frame2mm thick,powder coated round pipe without woodenhandles as per approved colour, shape,design,type by 164 Providing and supplying Officer high back Chair, The seat and back are made up of 1.2 cm thick hot pressed plywood, upholstered with fabric and moulded Polyurethane foam with PVC lipping all around.The back foam is designed with contoured lumbar support for extra comfort. BACK SIZE:65.0cm.(W) X 71.0cm.(H) SEAT SIZE:65.0cm. (W) X 65.0cm.(D) andreinforced with M.S. insert. The armrests are scratch and weather resistant. The armrests are fitted to the seat with seaUarmrest connecting strip assembly made of steel.The center pivot mechanism Is designed with the followingfeatures:360 revolving type.Tilt tension 5 adjustment. Upright locking.The pneumatic height adjustment has an adjustment stroke of 12.5 cm..The pedestal Is made of HR steel and fitted with 5 nos.twin wheel castors (castor wheeldia. 5.0cm.). The pedestal is covered with a P.P moulded cladding for modem and aesthetic looks.The pedestal is 65.0 cm. pitch-centre dla.(75.0 cm with castors). The twin wheelcastors are injection moulded In 30% Glass Filled black Nylon, as per approved colour, shape,design,type by engineer In charge. 165 Providing & Supplying table or size 1500mmx900mmx750mm, Top should be nnished with 18mm MDF Bos:d post formed Both side with 0.6mm laminate of approved make & design & with appropriate balancer on the bottom or the top. All verticals supportsincluding Modestypanel should be of 18mm prelaminated MDF Board with 2drawers & 16 Swing door per approved design.The drawers to beprovided with ai:proved handles and fixed on Telescope channels.AppropriateEdge Bendings to be provided where necessary with PVC beading 2mm thick to be provided. Footrest to be provided with 1Bmm MDF prelaminated board of the same color code.P&F PVC wire managers capslo be provided on the table top, as approved colour,shape, design,type by engineer In Charge 166 Providing & Supplying side table of size 900mmx450mmx750mm. Top should be finished with 18mm MDF Bos:d post formed with 0.6mmlaminate oras same as the Table,approved make & design & with appropriate balancer on the bottom or the topAllvert icals supportspanel should be of 1Bmm prelaminated MDF Board. Having 2Drawers & 1Swing7 door CPU unit. Keyboard tray, with mouse rest to beprovided.Appropriate Edge Bendings to be provided where necessary with PVC beading 2mm thick to be provided as per design.The drawers to be provided with approved handles and fixed on Telescope channels.P&F PVC wire managers caps to be provided on the table top, as per approved colour, shape,design, 167 Providing and $Upplylng table of size 1200mmX 750mmX750mm high as per design. The table top should be finished with 0.6mm thick laminated postrorming on 18mm thick MDF board.The 3 drawer unit (provided withlocking mechanlsm)and all other8 exposed vertical supports should be finished with steel members or approvedshade,colour and make.Appropriate moulding/edge bindingto be provided where necessary with PVC beading 2mm thick lo be provided as per approved colour, shape,design, 168 Providing & Supplying Computer table of size 900mmx450mmx750mm.Top should be finished with 18mm MDF Bos:d post formed with 0.6mmlaminate or as same as the Table,approved make & design & withappropriate balancer on the bottom or the topAllverticals supports panel should be of 1Smm 16.00 Each 12100.00 1g3500.oo prelaminated MDF Board. CPU uni Keyboard tray,with mouse restlo be provided.Appropriate EdgeBendlngs to be provided where necessary with PVC beading 2mm thck to be provided as per approved 169 Providing & Supplying depository/cashcabinet made up of CRCA steel with external size or 5g1 x 460 x 460 mm,2 nos of lockable drawers and single door cabinet fitted 3.00 Each 22848.00 68544.00with 6 leverlock system 1vith completein all respect. (approx weight 160 kg to 180 kg) as per approved 170 Book Case - 4 Door Book Case shall have the configuration or 914mm(W)x320mm(D)x1742mm(H). The unique design provides the right rigidity to the Top hinged doors ,which shall faci itate easy use.The Book Case shall be made fromprime quality steel. It shall have a Rigid Knock Down Conslructlon.The TopPannel, Back Pannel and Side Pannel are made from 0.7mm high yield CRCA andother components from O.Smm CRCA. Each door shall have a 6 Lever Cam Lock with Comrron Key. 3mm thick glass should beused in each door for clear inside vision whih shall besecured Ina metalframe through a rubber gasket.11 Scissor Mechanism should be providedin each door for 20.00 Each 17248.00 344960.00receding Inside the top or every compartment andItshall ensure parallel and smooth movement. Each door should be provided with plastic side end caps as handle which Is easy to grip.Each compartment shall have a storage shelf with good capacity. The 4 Door Book Case shall have 18mm PLB Top straight edge with PVC lipping.The Hn shlngshall Include Epoxy powder coated.Complete work as per the as per approved colour,shape,design,type by engineer in charge. 171 150 cm high fencing of precast R.C. posts of 15cmx15cm tapered to 10x10cm at top placed at every 3m apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth posts to be strutted with same R.C. posts provided with 6 horizontal lines and two diagonals of black barbed wire between the two posts fitted and fixed with G.I. staples including earth work in excavation etc. complete 172 FIRE FIGTHING WORKProviding, Fixing, Jointing, Testing & Commissioning of Heavy duty MS C class (Heavy) pipes conforming to IS 3589 / 1239 part-I for hydrant and sprinkler applicationsincluding cutting, screwing, welding etc. & forged steel fittings like elbows, tees, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts including cutting hole and chase in brick or RCC walls/ slab and making good the same. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of requiredshade complete as required. (Pipe to be tested @ 10Kgf/Sqcm for 2 Hrs.). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 mm dia 173 100mm dia 174 80mm dia 175 50mm dia 176 40mm dia 177 32mm dia 178 25mm dia 179 Supplying and fixing first -Aid Fire hose reel Drum wall mounted swinging type with MS construction powder painted in post office Red, conforming to IS 884-1985 with upto date amendments, complete with the following as required.(A) Thermoplastic / Rubber Hose(B)20 mmdia UL, FM Bronze / SS nozzle with 5mm orifice (C)Drum and brackets for fixing the equipments on wall.(D) Connections from riser with 20/25 mm dia Brass/GM gate valves with screwed end and conforming to IS:778 Class-1through Forged steel Screwed Union & M.S. pipe. Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . With 30 m x 20 mm High Pressure Braided Rubber Hose as per IS:5132 - 1969and Bursting pressure 42 Kg/sqcm 180 Supplying and fixing of SS 304 Single / Double headed oblique pattern hydrant landing valve (internal/external) with 75 / 100 mm dia flanged inlet & 63 mm dia instantaneous type female outlet coupling with cast iron wheel complete with ABS cap and chain and all accessories as per IS:5290-93 (Type-A) in cluding matching flange (14 mm thick),nuts, bolts, washers, gaskets,etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Single Headed with 75 mm Dia. Flanged Inlet 181 Supplying and fixing of flexible hose made with 100% polyester, black EPDM internal rubber lining with External coat of synthetic elastomer (IS:636, type-A)63 mm dia, 15 mtr. Long RRL hose pipe with instanteneous type 63 mm dia SS-304male and female couplings(IS:903) duly bound and riveted to hose pipes with copper rivets and SS wire etc. as required.Appropriate Test Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. 182 Supplying & fixing SS-304 Short Branch Pipeconforming to IS: 903:93 fitted with 20mm (nominal internal diameter)bore nozzle, for projecting water in form of solid jet. The Branch shall have 63mm Male Instantaneous Inlet, suitable for use with 63 mm size Fire fighting hoses. H.P. tested to 21 kgf/cm² for 2.5 minutes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 183 Supplying and fixing of 750 mm x 600 mm x 250 mm Outdoor application Fire Hose Cabinet made of 1.6 mm thick MS sheetDuly powder coated in red color externally and white internally with 6 mm thick glazeddoors with Expanded Metal 2 mm thick Jali including necessary locking arrangement suitable to accommodate 2 Nos 15 Mtr. Long RRL Hose and 1 No. branch pipe on Existing Wall / Angle Iron Frame as required. (Cost of MS structure for mounting Frame is to be Paid Extra) All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 184 Providing and fixing of Fire / Electrical Shaft Door made frompowder coated (50 Micron) aluminiumpartialy glazed with 6 mm thick glass and Partialy/ Fully Louvered with Outer frame of AluminiumSection of Size 100 mm x 45 mm x 1.5 mmand Shutters Top, Middle & sideSection of Size 82 mm x 45 mm x 1.5 mm, Bottom Section of Size 110 mm x 45 mm x 1.5 mmComplete with Hinges, Tower bolt, Handle, Aldrop, Locking Arrangement including dash fasteners of required dia and size, necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. as per drawings and the directions of Engineer-in-charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 185 Supplying, Installation, Testing & Commissioning ofElectrical Driven fire fighting duty Terrace pump as per TAC andIS 12469-1988., Factory assembledin Pump make OEMsuitable for automatic operation and consisting of following details given asA, B, C, D, E, F, G and H.(A) Horizontal End suction Centrifugal Back pull type pump complete for delivery of below mentioned discharge and Head(B) Material of construction : Pump Casing - Cast Iron, Impellor- Bronze, Shaft - SS 410, Packing - Mechanical Seal(C) Squirrel cage induction motor (IE-3 Class) suitable for 3 phase, 415 V, 50 HZ, Ac supply , Class -F Insulation, Synchronous speed not Exceeding 3000 RPM, T.E.F.C confirming to IP:55 , of required HP suitable for the above pump ,along with flexible (Love Joy type) coupling , coupling guard complete in all respect .(D)Common bed plate fabricated frommild steel channel for installation of pump and Motor including anti vibration pads.(E) The Hydrostatic tests (2 times of design operating head or 1.5 times the shut off head whichever is higher) and performance tests (to determine developed head, Pump BHP and efficiency v/s Flow) of pumps along with trip test shall be carried out at manufacturer’s works in Virtual / Physical presence of Department’s representatives.(F) Physical & Chemical Test reports of i) Pump casing (ii) Impeller (iii) Shaft (iv) Shaft sleeveand Dynamic Balance certificate is to be submitted by OEM(G) Suitable size Reinforced cementconcreat (M-30) foundation with foundation bolt, Nozing Angle of size 40mm x40mm x5 mm ( Cost of RCC Foundation to be paid Extra )(H) Weather proof hood fabricated from 5mm thick UV stablised FRP sheet supported by 50 mm x 50 mm x 5 mm Angle Iron fram above pumpset to protect it from weather All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR 450 LPM with 35 mtr head 186 Supplying and fixing Inlet Breeching Connection of CI body with Gun Metal male instantaneous inlet couplings with Inbuilt NRV, Drainage Connection with 50 mm Brass gate valvecomplete with PVC blank cap and chain as required for 150mm dia Outlet with 1 no. Matching Flange (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following Ways. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 4 Way 187 SITC of installation control valve of cast iron body and brass/bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continous alarm when the wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150mm dia 188 Supplying and Fixing of PN 16 Cast Iron Dual Plate Wafer Type Check Valve / Non return valve with SS / Bronze flap complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 mm dia 189 100 mm dia 190 150 mm dia 191 200 mm dia 192 Supplying and Fixing of PN 1.6Butterfly Valve (Wafer Type) with S.G Iron Disc and confirming to IS:13095 complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 mm dia 193 100 mm dia 194 80 mm dia 195 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 6 kg 196 Supply & Fixing of CO2 type Fire Extinguisher conforming to IS:15683:2018, charged with CO2 gas (purity 99.7% conforming to IS 15222), Powder coated Internal & External Surface Manganese steel ISI marked as per IS 7285 cylinder body , Wheel type Forged brass release valve ISI Marked as per IS 3224 with Inbuilt safety release device ((Fusible plug and Rupture Disc Type), 1.0 Mtr. Metal wire braided hose having minimum bursting pressure of 140 Kgf/cm2, Horn with metallic thread connection, QR code for Product Traceability,including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSRCapacity 4.5 Kg. 197 Supplying and Fixing ofGalvanized Mild Steel fire bucket Confirming to IS: 2546 : 1974 with one coat of primer and two coat of enamel paint of approved shade on Angle Iron ( 50 x 50 x 5 mm) Stand of Size 800 x 1240 x 400 mm with MS 22 SWG Galvanized Canopy, 4 Hooks for Bucketsincludingassociated civil works etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 198 SITC of UL 10th edition / EN54 / VDS certified Addessable Manual Call point (MCP) with LED/ FIRE Indication Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 199 SITC of UL 10th edition / EN54 / VDS certified Addressable sounder with strobe light,Loop Powered / Direct powered from FACP with sound level 90 dB and programmablefrom the panel etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 200 SITC ofResponse Indicatorfor indicating the activation of the Remotely located Detector for Conventional type detectors as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 201 SITC of EN / LPCB/ UL listed / approved conventional automatic fire Alarm Rate of Rise cum fixed temperature thermister typeHeat Detectors , 12 / 24 volt D.C., visual alarm indicator (LEDs) Blink - green in stand by and Steady - red in alarm complete in all respectswith baseas required.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 202 SITC of EN / LPCB/ UL listed / approved conventional automatic fire Alarm Optical/Photoelectric type smoke detectorsof photo-optic sensing chamber, 12 / 24 volt D.C., visual alarm indicator (LEDs) Blink - green in stand by and Steady - red in alarm complete in all respectswith baseas required.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 203 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR2 x 1.5 sq.mm 204 3x 1.5 sq.mm 205 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR4 Pair 206 2 Pair 207 Supplying and fixingof CE certified and UL listed GI wire mesh cable tray made from spot welded steel wirehot dipped galvanised between 60 and 80 microns of zinc as per BS 729including horizontal and vertical bends, reducers, tees, cross members and other OEM made accessories like wall clamp, hold down clamps, Earthing terminal, brackets as required, and duly suspended from the ceiling with electro-zinc coated TF rods,etc. as required of following sizesAll as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .500 mm x 100 mm x 6 mm 208 300 mm x 100 mm x 6 mm 209 SITC of UL 10th edition / EN54 / VDS certifiedActive Repeater Panel for Fire Alarm System with inbuilt networking port (both RS485 & Ethernet),Serial port for printer,two supervisory inputs,two position key switch and USB port for programming. The Repeater Panel shall allow users to acknowledge, reset,silence, program, view hisory events.etc (All functions similar to main panel)The user interface of the repeater panel shall be same as the Main Controller with menu driven user interface with smart search.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 210 SITC of PA system Operator Console of following wattage to be installed withConventionalfire alarm systemcomplete with following capacity , channel mixing amplifier , 1 no cardioids goose neck microphone , 1 no professional grade cassette deck/ CD Player , 16 zone floor selector console ,equipment rack complete in all respects. PA system shall be coupled to the Fire Alarm System. Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 1x 240 Watt 211 SITC 6 watt Speakermounted in M S sheet box with perforated front mesh for PA and Emergency System. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 212 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRMedium point (up to 6 mtr.) 213 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRLong point (up to 10 mtr.) 214 Long point(up to 10 mtr.) 215 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRMedium point (up to 6 mtr.) 216 Long point(up to 10 mtr..) 217 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR3x 1.5 sq.mm 218 3x 2.5 sq.mm 219 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 220 2 x 6.0 sq. mm. + 1 x 4.0 sq. mm. 221 2 x 6.0 sq. mm. 222 4 x 10.0 sq.mm 223 4 x 16.0 sq.mm 224 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 225 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 226 Providing & Fixing ofof BLDC Technologyventilating fans , single phase with PVC impeller, ABS body, Double Ball bearing, automatic back lower shutterincluding making connection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .250 mm sweep with Min. Air delivery 1150 cmh, 1300 RPM 227 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 228 Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating 229 Three pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 230 50/63 A rating 231 100 A rating 232 Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 233 50/63 A rating 234 Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock,min. operation 10,000 upto 63 A rating and5000 for 100 Aratingand minimum phase termination capacity of 35 sq.mm. rigid wire, IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRTwo pole 30 mA sensitivity6A-32 A rating 235 40 A rating 236 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRGlazed door (single phase) IK-09 and IP-43 with Metal end box8 Way (8+2) 237 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box6Way(Incomer 8,Sub Incomer2+2+2) 238 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box withprovision of incomer suitable for MCB / RCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 100 A rating copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR6 Way(8+18) 239 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 240 Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,minimum width ofswitch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 25 Amp.2 Moduleswitch With LedIndicator 241 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 Amp. 2 Module Socket 242 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSRRJ-11 telephone jack Double line 243 RJ-45, Cat 6 computer jack with shutter 244 Providing & Fixing offollowing size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1 Module 245 4 Module 246 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR5 step fan regulator 2 Module 360 dgree rotating 247 Plate Earthingas per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 248 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 25mm x 6mm G.I. ( Hot Dipped) Strip 249 Supply & Laying following size B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 mm dia. 250 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1170mm(+/-10%) LED batten with min. lumen output 2200 lm 251 570mm (+/-10%) batten with min. lumen output 1000 lm 252 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Minimum lumen output 3600 lm 253 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Minimumlumen output 650 lm 254 Minimum lumen output 1950 lm 255 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 256 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR2 pair 257 Supply and Laying of PE Insulated, PVC Inner Sheathed, armoured & PVC Sheathed Telephone Cable. with 0.5 mm thick Solid Annealed Bare Copper Conductor as per IS: 8130/84 telephone cable confirming to TEC specificationsGR/WIR 06/03, Mar.-2002 in existing pipe / open trench / Cable tray / on surface including making necessary connection, testing etc. as required of size. For additional technical parameters of product / work refer Annexure A attached with this BSR50 pair 258 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 mm 259 Supplying and fixing of ISO Certified company made Krone module with base frameas per PWD specification for electrical Works, in the recess / surface made out of 16 SWG sheet steel box, front openable, having locking arrangements duly powder painted., including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .50 Pairs 260 CCTV SURVEILLANCE WORKSupply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Modular Patch Panel Loaded with Cat -6A I/O 261 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 262 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Cat 6A, Sheilded Information Outlet 263 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Single Aperture 264 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Modular Patch Panel Loaded with Cat -6A I/O 265 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 9 U Rackwith Width 600 mm & Depth 400 mm + 100 mm 266 Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent PoE Giga Ethernet Switch providing 24 x 10/100/1000 MBPSPoE Giga Ethernet ports and with min 4 SFP Giga Ports (provision for Fiber Giga connectivity) with provision of minimum Stacking of 06 Switches with minimum 370 Watt PoE Power Budget with related LAN Base Software including making connections etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 267 SITC of 2 MP IR Fixed Dome Network Camera -1/2.7″ Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.002Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Video tampering, UL, CE, FCC certified. 268 Supply Installation testing and commissioning of 32 Ch Network Video Recorder- Connect Up to 64 IP Cameras, Up to 12 Megapixels Resolution, HDMI1/VGA1 and HDMI2/VGA2 outputs provided, atleast one HDMI output with 4K (3840 × 2160), atleast one VGA output with 2K (2560 × 1440) resolution, Support H.265/MJPEG, Supports N+1 hot spare system, Supports RAID0, RAID1, RAID5, RAID6 and RAID10, Supports HDD hot swap, Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, 1 × eSATA interface, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 10 TB, Front panel: 2 × USB 2.0; Rear panel: 1 × USB 3.0, Alarm I/O 16/4, RS-232, RS-485, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface,Multiple network monitoring: Web viewer, CE, FCC, UL certified. with 30 days backup capacity asrequired. 269 SITC of professional PC alongwith printer and other accessories as required having minimum i7 processor, 8 GB graphic card 1 Tb SSD as per requirement. 270 SITC of 42 inch full HD professional LED display for CCTV monitoring. 271 External Electrical WorkS I T C of star ratedAluminium wound distribution Transformerof following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star - 1 & BIS approved as per IS 2026- 1977 & lossesas defined as per 2014 (Fourth Revision) Level-1 . including standardaccessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint,including carrying of pre-commission Testing & Charging of Transformer complete in all respect .The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including testing from CTLof discombefore charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 KVA 272 SITC of PLC Based Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stopcommands, control Relays , Ammeter & Voltmeterwith selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets: Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturer shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .20 to 40 KVA 273 Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as requiredcomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 274 Providing & Laying XLPE insulated three core ArmouredAluminiumcable for working voltage 11 K.V.(E) confirming IS :7098 P - 2withH4- Grade electrolyticaluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .3 core 150.0 Sq.mm 275 MAIN LT PANELSITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra )(d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 276 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR4 pole MCCB With Thermal Magnetic release160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 277 up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting 278 Supply and fixing of following accessories for Moulded case circuit breaker (MCCB)compatible to main MCCB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Shunt Trip Release 279 Under Voltage Release 280 Extended Rotary Handle 281 Auxiliary contact 282 Spreaders for 250A, 4 Pole MCCB 283 Spreaders upto 125A, 3 Pole MCCB 284 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 0.5 A to 5 A rating 285 Providing & Fixing of ISO certified company made Four Pole By pass Change Over Switch conforming to IS:13947(Part 3) : IEC:60947-3-1 and IEC:60947-6-1, Open execution type in the following ratings.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .100 A 286 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 0.5 A to 5 A rating 287 Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating 288 Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 289 50/63 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
28.
Housing Urban and Rular Development #10204751 Price Bid
Tender For Lake Front Development At Porur Chennai.; 1 CIVIL WORKS 2 Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. 3 Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification. 4 Clearing Scrub Jungle, etc., complete complying with standard specification and as directed by the departmental officers. 5 Installation of Vertical Bored cast in situ RCC piles of 300 mm diameter and M-30 grade of concrete in all types of soils, using Standardised Concrete Mix of following grade, with sulphate resistant Cement or OPC/PPC, etc and Crushed Stone Sand and 20mm and down graded HBGS jelly coarse aggregate. The rate includes cost for placing of reinforcement cage in bore hole in correct position, cost of boring to the required depth with Bentonite solution with temprory casing of required length, conveyance of RMC to site and pouring concrete using Tremine pipes, conveyance of all materials to the site including all tools and plants, shifting the plants and equipments from one point to another, excavtion of mud pits for circulation of Bentonite soultion, closing the mud pits to original level and mud removal with initial lead and lift but including dismantling the concrete above the cut off level etc complete as directed by the departmental officers including socketing. The reinforcement cage should be welded properly for lifting. The concrete cubes to be tested as per IS 456-2000. Acceptance criteria by clause 16.1. Frequency of testing as per 15.2.2. Testing to be conducted at both the ends at site as well as RMC plant. Pile driving depth should be decided by the departmental officers at site. The length of pile for payment shall be measured from top of shoe to the bottom of the pile cap. (Cost of Reinforcement provided for Pile and Welding charges shall be measured and Paid separately) 6 Installation of Vertical Bored cast in situ RCC piles of 380 mm diameter and M-30 grade of concrete in all types of soils, using Standardised Concrete Mix of following grade, with sulphate resistant Cement or OPC/PPC, etc and Crushed Stone Sand and 20mm and down graded HBGS jelly coarse aggregate. The rate includes cost for placing of reinforcement cage in bore hole in correct position, cost of boring to the required depth with Bentonite solution with temprory casing of required length, conveyance of RMC to site and pouring concrete using Tremine pipes, conveyance of all materials to the site including all tools and plants, shifting the plants and equipments from one point to another, excavtion of mud pits for circulation of Bentonite soultion, closing the mud pits to original level and mud removal with initial lead and lift but including dismantling the concrete above the cut off level etc complete as directed by the departmental officers including socketing. The reinforcement cage should be welded properly for lifting. The concrete cubes to be tested as per IS 456-2000. Acceptance criteria by clause 16.1. Frequency of testing as per 15.2.2. Testing to be conducted at both the ends at site as well as RMC plant. Pile driving depth should be decided by the departmental officers at site. The length of pile for payment shall be measured from top of shoe to the bottom of the pile cap. (Cost of Reinforcement provided for Pile and Welding charges shall be measured and Paid separately) 7 Installation of Vertical Bored cast in situ RCC piles of 450 mm diameter and M-30 grade of concrete in all types of soils, using Standardised Concrete Mix of following grade, with sulphate resistant Cement or OPC/PPC, etc and Crushed Stone Sand and 20mm and down graded HBGS jelly coarse aggregate. The rate includes cost for placing of reinforcement cage in bore hole in correct position, cost of boring to the required depth with Bentonite solution with temprory casing of required length, conveyance of RMC to site and pouring concrete using Tremine pipes, conveyance of all materials to the site including all tools and plants, shifting the plants and equipments from one point to another, excavtion of mud pits for circulation of Bentonite soultion, closing the mud pits to original level and mud removal with initial lead and lift but including dismantling the concrete above the cut off level etc complete as directed by the departmental officers including socketing. The reinforcement cage should be welded properly for lifting. The concrete cubes to be tested as per IS 456-2000. Acceptance criteria by clause 16.1. Frequency of testing as per 15.2.2. Testing to be conducted at both the ends at site as well as RMC plant. Pile driving depth should be decided by the departmental officers at site. The length of pile for payment shall be measured from top of shoe to the bottom of the pile cap. (Cost of Reinforcement provided for Pile and Welding charges shall be measured and Paid separately) 8 Refilling with excavated earth in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification. 9 Supplying and filling with earth up to 10 Km for foundation and basement, etc., including watering and consolidating, etc., complete complying with standard specifications and as directed by the engineer-in-charge 10 Supplying and filling in foundation, basement, etc with Stone Dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 11 Supplying and filling in foundation, basement, etc with Crushed Stone sand filling in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 12 Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 13 Plain Cement Concrete 1:2:4 (one part of cement, two part of Crushed Stone Sand (M- Sand) and four part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 14 Construction of Granular sub-base of required compacted thickness by providing laying, spreading and compacting of Close graded Material conforming to Grading V of Table 400-1 of MORTH clause 401,mixing in a Wet Mix Plant of 200 tonne capacity at OMC, carriage of mixed material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory roller 8-10 tonne to achieve the desired density of 98% including protection of edges of GSB layer, cost of all materials, labour, hire charges of machinery, lighting, guarding, barricading, maintenance of diversion road, loading & unloading, all lead and lift etc., to achieve minimum CBR value of 30%(Compacted Thickness) in accordance with MORT&H technical specification clause No. 401 and with all other incidental charges and as per the direction of the Engineer-In-Charge of work. 15 Damp proof course with Cement Mortar 1:4 (One Cement and Four sand) 12mm thick mixed with best approved quality water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used and finishing, curing etc. complete complying with standard specification. 16 Providing Anti-termite treatment to soil adjecent and under building foundation, plinth periphery of the building by application of chemicals of IS 63613 part I to IV in stages to suit the progress of work consist as per the detailed specification as below.Including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing etc., complete and as directed by the departmental officers. 17 Random Rubble masonry in Cement Mortar (1:3) etc., Complete complying with standard specification and as directed by the Departmental Officers 18 Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid). 19 Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid). 20 For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc. 21 For plane surfaces such asrectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc. 22 For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc. 23 Centering for curved surfaces of all RCC items of work 24 Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part there of but not less than 30 cm, over the initial 3.00 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the department officers. 25 Providing and laying in position, Standardised Concrete Mix M-25 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kg/mᶾ and maximum water cement ratio of 0.50, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers.The coarse and fine aggregates to be used should comply with the requirements of IS Standards.(No separate payment will be made by the Department for the excess usage of materials). 26 Foundation and Basement 27 For Ground Floor 28 For First Floor 29 Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 400 kg/mᶾ and maximum water cement ratio of 0.45, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers.The coarse and fine aggregates to be used should comply with the requirements of IS Standards.(No separate payment will be made by the Department for the excess usage of materials). 30 Foundation and Basement 31 Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) 32 Brick work in Cement Mortar 1:3 using best quality of Second Class Ground Moulded Chamber Burnt Bricks 9 x 4-3/8 x 2-3/4 for foundation and basement including curing, etc., complete complying with standard specifiction. 33 For foundation & basement 34 In Ground floor 35 In First floor 36 Brick partition walls of 11.50cm thickness using best quality II Class Ground Chamber Burnt Bricks of size 9 x 4-3/8 x 2-3/4 in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately). 37 Ground floor 38 Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. 39 Inner Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. 40 Outer Plastering with Cement Mortar 1:4 (One cement and Four sand), 20mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. 41 Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers. 42 Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush.Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed.Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete. 43 White washing two coats with freshly burnt white shell lime in all floors including cost of lime, blue powder fevicol type gum, brushes, scaffolding charges, etc., complete complying with standard specification and as directed. 44 Supplying and painting the walls with two coats of wall putty as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications and as directed by the departmental officers. (The wall putty shall be got approved by the Executive Engineer before use of work). 45 Painting newly plastered wall surface with two coats of ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. Interior painting 46 Painting two coats of newly plastered wall surface with ready mixed Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. 47 Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) 48 Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) 49 Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers. 50 Flooring with first quality design ceramic tiles of all colours of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand)base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) 51 Paving the floor with best quality Double Charged Vetrified Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three M-sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification.(The make and brand of the tiles should be Johnson / Kajaria / Somany / Nitco / RAK which has to be got approved by Executive Engineer before use on works). 52 Providing And Fixing Machine Dressed Grey Granite Slab All Sides Machine Cut of Size 0.60 M X 0.60 M Size And 50 mm Thick Granite Slabs For Platform(Pavement) Including Cost And Conveyance ofGranite From Available Source Including Labour Charges For Fixing the Slab In Position To The LineLevel And GradientIncludingPointing With cm.1:3 And All Other Incidental Charges Etc.Complete 53 Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise andsimilar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification. 54 Paving the floor with Cement based Hydraulically pressed Anti skid tiles (pattern design) - 20 mm thick (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works). 55 Dadooing walls with Colour designed digital print ceramic tiles, with borders, with size of 300mm x 450mm x 8mm and above set in Cement Mortar 1:2 (One Cement and Two M-sand)10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. nbatly in all floors, curing, etc,,complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be like Johnson / Kajaria / Somany / Nitco / RAK or Equivalent which has to be got approved by Executive Engineer before use on works). 56 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between.The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete.The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete 57 Nosing the granite slab - single nosing as directed by the engineer-in-charge 58 Grooving the granite slab as directed by the engineer-in-charge 59 Manufacturing, supply & fixing of precast kerb stone of size 400mmx259mmx200mm thick made of M 20 grade of concrete rectangular in shape with one corner chamfered by 100 mm x 100 mm as per approved design i/c cost of all material, labour and curing etc., complete. as per IRC 5758 - 1984. 60 Supplying and laying hydraulic pressed monolithic natural grey colour cement concrete inter locking paver block of 63mm thick, in cement concrete 1:2:4 (one cement, two sand, four aggregate) using difference design and with stand for pressure of 150 - 200 kg/m2 over the existing sand cushion by using earth rambers and also vibratting the concrete blocks often laying using plate vibrators etc, complete as directed by the departmental officers. 61 Supplying and fixing of M.S.grill of approved design for grill gate, grill work to doors and windows openings ramp etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including priming coat of best approved quality red oxide primer etc., complete complying with standard specification. 62 UPVC Window Specification:Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle.The corners and joints should be welded and cleaned.Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong lockingsystems and as per size for arresting noise and energy loss.The connecting mechanism between sash and outer frame that enables opening of the window.The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames.The window should be got approved from the Executive Engineer before use on work 63 Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm.The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber.The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug. 64 ABS DOOR Specification:Providing and fixing of ABS (Acrolynitrile Butadiene Styrene) Door using factory made plain FPVC (Foamed Polyvinyl Chloride) door frame of the size 105 x 40mm with a wall thickness of 10mm made out of extruded rigid FPVC profile mitre joined with 10 Nos. of 50mm long screw.The door frame shall be fixed to the wall by using 80mm long screws through the frame with the help of PVC fasteners to be provided for each vertical member, stiffeners of (‘U’ Channel of size 29 x 9 x 1mm, 150mm long) 3 Nos. at hinge point, frame reinforcement of (‘U’ GI Channel of size 46 x 22 x 0.06mm), bottom tie rod of (‘U’ GI Channel size of 15 x 15 x 1mm), the ABS Shutter of 35mm thick factory made plain pre-laminated.ABS (Acrolynitrile Butadiene Styrene) door shutter moulded in different designs, consisting of all round Frame made out of water proof solid foam PVC bar of size 20x32mm, reinforced by 32 x 32mm - 2 Nos. for vertical made out of LVL (Laminated Veneer Lumber), core material of 32mm thick high density craft paper honey comb board, sandwiched on both sides with pre-laminated ABS sheet thickness of 1.5mm.PVC edge banding of size 0.45mm on the vertical sides.Hardware made out of ball bearingbutterfly hinges - 3 Nos. for each shutter and ISI make SS round lock complete, including cost of Materials, conveyance and all other incidental charges and labour charges for fixing the Door neatly etc., complete complying with the standard specification. The door shutter and frame should be got approved from the Executive Engineer before use on workPlain Pre-laminated Door 65 Fabrication supply and fixing in position of aluminium natural colour matt finish louvered ventilator in all floors made with extruded aluminium section of following size with necessary accessories such as rubber beading, best quality of handle including supplying and fixing of 4 mm thick plain glass including cost of all materials, labour power consumption required for fabrication drilling holes in RCC column/floor slab/ masonry wall wherever necessary with power drills to the required extent and making good to the original condition after fixing etc., and as directed by the departmental officers etc. complete.The aluminium frames to be anodised under electrically controlled condition in accordance with ISI 1868/ 1962 specification for an average anodic film thickness of not less 15 microns and all the materials should be got approved by the Executive Engineer before use on work. Outer frame alround section of size 62x38x2mm @ 1.174 kg/ m vertical louvered section of size 60x30x4mm @ 1.27 kg/m and aluminium clips of size 19.05x10.27/11.05x1.20mm @ 0.169 kg/m. 66 Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification 67 Roofing with best quality prelaminated Polycarbonate Sheet 6mm thick of approved colour design and quality including cost of self tapping screws between washer and cutting the sheet to required slope if found necessary during execution of work, including charges for machine etc., complete, as directed by the engineer-in-charge 68 Supplying and fixing of Exterior WPC louvered panel for cladding and roofing works with material specifications: Material - WPC, Size - 2900 x 200 mm, Design exterior decorative panel, Color - Brown, Usage/Application for all kinds of exterior work, Thickness - 26mm, Core Filling - Fly Ash, Packaging Type - fully packed, etc., complete as directed by the engineer-in-charge 69 Supplying and Fixing ofCNC cut perforated Enclosure for EB transformer and EB pillar Boxes by using CNCMS Sheet (2mm thick), doorhinged with vertical support of80X40 mm TubularPost including horizontal Support and Stiffener (40 x40 x2mm)for MS sheet including Powder coating ofall structural members and labor for fitting , welding andtransportation of thematerial from thefactory to Site as directed by the engineer - in charge. 70 Providing and fixing of Aluminium Composite Panel (ACP) 4 sided having 50 x 25 x 1.50mm frame work vertical and horizontals out of specially designed extruded sections withstand wind pressure of 180 Kg/sq.m and fabricated fixed at all level elevation and heights.The extruded section cutting and fixing required space extruded section shall be of 6063 and alloy of BSH 9 confirming T is – 63400 rate shall included to fix the main frame with necessary clamps, fasteners, bolt nuts etc.The main frame of extruded section shall be of 22843 & 22739 (H9) grade conforming to BS 4174 (or) IS 8147.Rate shall included 4mm thick ACP sheet (0.25 + 3.5 + 0.25) alstrong or equivalent fixing with spacer tape and the ACP sheet bounded with special type structural sealant of dow corning 789 or equivalent in dust free conditions the gaps between ACP sheet to be filed with whether sealant and backer rod or 12mm foam sheet to ensure water and air tightness in all complete complying with standard specification as directed by the departmental officer 71 Refixing of damaged cement concrete solid block masonry in CC 1:3:6 (One of cement, three of sand and six of course aggregate) using 6mm and below HBG stone jelly with compressive strength of 50 kg/cm2 in cement mortar 1:5 (one of cement and five of sand ) including curing and neat finish etc., complete complying with standard specification and as directed by the departmental officers at site of work 72 Supplying and fixing of cement concrete solid block masonry by using solid blocks of size 400x200x150mm confirming to IS 2145-1965 made in CC 1:3:6 (One of cement, three of sand and six of course aggregate) using 6mm and below HBG stone jelly with compressive strength of 50 kg/cm2 in cement mortar 1:5 (one of cement and five of sand ) including curing and neat finish etc., complete complying with standard specification and as directed by the departmental officers at site of work. 73 Supplying and providing chain link fence with RCC posts.The RCC postswill be of 2.5m c/c and of 2.75mheight.The post will be 100mm square at top and 150mm square at bottom 2.15m height above ground level and 0.60m below ground level, in R.C.C 1:1.5:3mix using 12 to 20mm gauge stone jelly with necessary reinforcement moulding work and rendering smooth with cement at 15kg/cu.m etc., complete and fixed in c.c. foundation in 1:4:8 using 40mm size stone jelly. The foundation is of size 45x45x90 with sand filling 15cm height. The fencing will be of chain link 75mm size, 10 gauge. The height of fence is 2.0m after leaving 75mm gap from ground level including fixing the fence with the posts using G.I binding wire, etc. complet.ISI STD 74 Supplying and fixing Country wood scantlings for door, windows, joints, rafters, etc., or any other works using country wood scantlings in following lengh and complete it in all floors including labour charges for the manufacture of frames as per standard specification. 75 Country wood scantlings below 4m in length 76 Providing two legged Scaffolding using 15cm dia casurina post of 4m over all length (3m height + 0.5m Projection + 0.5m into the ground) the distance between the two rows being 1.25 and the spacing of posts being 2.0m in both the rows with two horizontal posts with 0.5m. Overlap on either side and braces at 2.0m centre to centre including longitudinal and transvers middle braces to step up and providing a platform with country wood planks of 40mm thick and 1m width, etc. in acomplete from using coil and nails - 1RM 77 For Initial height of 3.00 metre 78 For every additional height of 2.5 m above initial height of 3 m 79 Supply and fixing of 3-seater metal garden swing chair with canopy of material and specifications: Seating capacity - 3 seater swing, Material- metal, Appearance - modern with canopy, Cushion - Included, Usage/Application - balcony, garden, lounge, etc., Cushion material - polyster, etc., complete, as directed by the engineer-in-charge 80 Supplying,erectingandFixingprecast reinforcementbench with back rest. Bench shall consist of 2 nos. L shaped bases support in natural cement color of thickness 100mm, back height 1000mm, front height 450mm, base width 620mm and 5Nos Reinforced Concrete planks in red colorandsizeof 1500x100x50mm and 1no. reinforcedconcrete plank of 150x200x50mm: manufactured by using M-30 grade concrete & reinforced suitably: all parts to be joined with galvanized nuts and bolts of suitable size. 81 Supply & placing of FRP heavy duty three compartment Dustbin of size 1200 x 450 x 900 mm with top cover 82 Supply & placing of light weight concrete Dustbin of size 450 dia x 900 mm with top cover 83 Supply and placing of Monkey DustbinFRP – 2 Layers to a height of 3½ and width of 2½ 84 WATER SUPPLY AND SANITARY WORKS 85 Supplying and fixing in position best approved of BIS quality 110 mm dia PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of U clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification. 86 Supply and providingPriming Tank made up of PVC, Make: SINTEX / EQUIVALENT 87 Internal water supply - Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works. 88 For laying PVC pipes of dia 32mm 89 External Water Supply - Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works. 90 Above Ground Level 91 For laying PVC pipes of dia 40mm 92 Below ground level 93 For laying PVC pipes of dia 50mm 94 For laying PVC pipes of dia 40mm 95 For laying PVC pipes of dia 25mm 96 Supplying, laying and jointing CPVC pipes of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using CPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto etc., complete complying with standard specifications.The CPVC pipes shall be got approved by Executive Engineer before use on works.(Above Ground Level) (Internal Water supply) 97 Above Ground Level 98 For laying CPVC pipes of dia 32 mm 99 For laying CPVC pipes of dia 25 mm 100 Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements).The valves to be used on work shall be got approved by the Executive Engineer before use on work. 101 Gate valve 102 Fixing Gun Metal Gate Valve of 25 mm 103 Fixing Gun Metal Gate Valve of 40 mm 104 Wheel valve 105 Fixing Gun Metal Wheel Valve of dia 25 mm 106 Fixing Gun Metal Wheel Valve of dia 40 mm 107 Providing, fixing, Testing & Commissioning of PVC Ball valve with quarter turn including all necessary fittings & accessories complete. PIMTAS / AQVASTAR make 50 mm ( 2 ) 108 Providing, fixing, Testing & Commissioning of PVC Ball valve with quarter turn including all necessary fittings & accessories complete. PIMTAS / AQVASTAR make 40 mm ( 1.5 ) 109 Providing, fixing, Testing & Commissioning of PVC Ball valve with quarter turn including all necessary fittings & accessories complete. PIMTAS / AQVASTAR make 25 mm (1.00”) 110 Supplying and fixing in position 15mm dia brass CP Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works). 111 Supplying and fixing in position Health faucet of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works). 112 Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia B class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). 113 White Glazed Wash Hand Basin 114 With Pedestal 115 Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks). 116 Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works). 117 Supplying and fixing best approved best quality brass CP soap tray of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications.(The soap tray should be got approved by Executive Engineer before use on works). 118 Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level. 119 For laying PVC pipes of dia 110 mm 120 Supplying and fixing in position PVC cowls of 110 mm dia of best approved quality conforming to BIS, etc., complete complying with standard specifications.(The PVC cowl should be got approved by the Executive Engineer before use on works). 121 Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with P or S trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers.(The water closet should be got approved by the Executive Engineer before use on works). 122 Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm P or S trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications.(The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works). 123 White glazed European Water Closet with 10 litre capacity PVC flushing tank fixed on to wall 124 Supply and fixing in position of best Indian make white glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers.(The urinal should be got approved by the Executive Engineer before use on works.) 125 Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works).Nahani Trap of size 100 x 75mm with stainless steel gratings 126 Supplying and fixing in position 150 x 100mm P or S stoneware gully trap A grade with CI double gratings of size 150 x 150mm and 230 x 230mm at bottom and top respectively with necessary earth work excavation laid over a bed of brick jelly cement concrete 1:3:6 (One cement, Three sand and Six broken brick jelly) 150mm thick using 40mm size broken brick jelly including necessary brick work and plastering including dismantling masonry wherever necessary and re-doing the damaged portions to the original conditions using cement concrete 1:3:6 using 20mm stone jelly for fixing the gully trap and giving connections to stoneware sewer line etc., complete complying with standard specifications. [Earth work excavation, brick work, plastering shall be measured and paid separately]. The stoneware gully trap should be got approved by the Executive Engineer before use on works. 127 Supplying and fixing single phase 1 HP Monoblock pumpset as per I.S.I. specification on suitable pedestal with foundation bolt and nut including labour. Supply and fixing of starter and main switch suitable for 1 HP pumpset on suitable angle iron frame work with necessary labour including panel board.Supply and fixing 1 No. foot valve 1 for the 1 HP Mono block pumpset supply and run of 4 of 10 sq.mm. in PVC pipe with 14 SWG TC wire etc., complete. 128 Construction of Inspection chamber of size (clear 0.60x0.60x1.00) with necessary earth work excavation, sand filling, CC 1:5:10, brick work in CM 1:5, plastering in CM 1:5 12mm thick, Plastering in CM: 1:3 20mm thick, Precast slab 50mm thick, fabrication etc. complete as directed by the engineer-in-charge 129 Providing rain water recharging collection pit having a size of 900mm dia to a total height of 1200mm is 150mm above ground level and 1050mm below ground level with necessary augar bore of300mm dia to a depth of 3000mm from bottom level of collection pit and filled with 20mm HBG stone jelly inside of augar bore. The sides of collection pit provided with RCC Well ring of inner size of 900mm x 300mm x 50mm with 6mm reinforcement on both directionat 200 mm c/c using RCC 1:1/2:3 (one cement, one and half sand and three HBG jelly). The top of collection pit is finished with 50mm thick cover slab, The collection pit is filled with course river sand at top, 20mm HBG stone jelly at middle and 40mm HBG stone jelly at bottom of a depth of 300mm, 450mm and 450mm respectively. The rate is including the cost of RCC well ring and filling materials, RCC cover slab, drilling hole and labour charges for erecting the well ring etc.,and as directed by the departmental officers. 130 Supply, Fixing & commissioning of Pop up spray RD 1804 SAM PRS Series Spray bodies with high efficiency HE VAN Nozzle capable of covering radius of 0.9-4.6m at 1.0 - 2.1 Bars, pressure with Matched precipitation rate, tactile click and DU >0.7. Triple Blade Wiper Seal precisely balances flushing, flow- by and debris protection to optimize performance and durability at pop up and retraction. Precision-controlled flushing at pop-up and retraction clears debris, ensuring positive stem retraction in all soil types. Unique debris pockets hold grit in place, removing it from circulation and preventing long-term damage. Parts resistant to corrosion in treated recycled water containing chlorine. Pop spray body shall with stand upto 6.9 bar. Built-in Seal-A-Matic™ (SAM) check valve. Traps water in lateral pipes in elevation changes of up to 14 feet (4.2 m). PRS Maintains constant outlet pressure at 30 psi or 45 psi at varying inlet pressures. etc., RD1804- SAM PRS-HE VAN incl installation charges 131 Supply of large capacity Disc filter 25 M³ / Hr including installation charges. (brands like Rain Bird or equivalent) 132 Flexible polyethelene irrigation pipe 16 mm dia / 2.5 / 1.1 - 1.4 mm CL - II. Netafim including installation charges. 133 Supply of endcap, nipple, start nipple, rubber grommet 16 mm dia. Netafim including installation charges. 134 Supply of Pressure compensated dripper with 2 / 4 / 8 LPH outlet flow. Rain Bird / Netafim make including installation charges 135 Supply of Micro sprinkler of half & full circle with 55 LPH output flow with necessary micro tube & stake. Rain Bird / JISL make including installation charges. 136 BOREWELL 137 Drilling of 12 dia vertical borewell so as to have a finished size of 6 dia borewell in boulder area to any required depth as decided by the TWAD Board Officers including Transportation from one place to anothr place with in Tamilnadu State by direct or reverse rotary mud circulation method using Contractors rig tools, fuel, labourers etc 138 Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 140 mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs, fuel, labour and drilling bentonite and water required for drilling at site ( Site will be shown by the TWAD Board Officers) including construction of mud pit 139 Drilling of 140/150 mm pilot bore - Upto 60 m Depth ending below ground level 140 Drilling of 140/150 mm pilot bore - From 60 m upto 90 m Depth ending from ground level 141 Drilling of 140/150 mm pilot bore - From 90 m upto 120 m Depth ending from ground level 142 Reaming 300 mm dia pilot bore to 400mm/ 450mm dia bore as directed by the TWAD Board Officer. 143 Upto 60 m depth ending below ground level 144 Reaming 140/150 mm dia pilot bore to 300mm dia bore as directed by the TWAD Board Officer. 145 Upto 60 m depth ending below ground level 146 From 60 m depth and upto 90 mt depth ending below ground level 147 From 90 m upto 120 mt depth ending below ground level 148 Supply and laying following dia PVC casing pipe with excise duty as per IS 12818 / 2010 149 200mm dia CS 150 150mm dia RS 151 Labour charges for inserting PVC casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC couplers with cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the Executive Engineer of Departmental officers. 152 200mm dia CS 153 150mm dia RS 154 Supplying and filling with river pebbles in annular space between bore and PVC pipe up to hard rock 155 Charges for developing the borewell with air compressor of 300 CFM capacity (Minimum 8 Hours) including ransportation labour and fuel charges for compressor as directed by TWAD Board Officers and conducting yieldtest by V notch method. 156 Supply ,erection and testing & commisioning of 3HP submersible pumpset in the to suit 200mm borewell of capacity of 4800 LPH @ 265Ft, max. total head of 280 Ft pumps fitted with bronze impellers and having delivery size of 40mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge and other required supporting items like SS hose nipple, nylon rope, clamps, bolt and nuts,GI nipple, 50mm dia HDPE hose of required length etc completed and as directed by the officer incharge. 157 Supplying and fixing single phase 5 HP Monoblock pumpset as per I.S.I. specification on suitable pedestal with foundation bolt and nut including labour. Supply and fixing of starter and main switch suitable for 5 HP pumpset on suitable angle iron frame work with necessary labour including panel board.Supply and fixing 1 No. foot valve 2 for the 5 HP Mono block pumpset supply and run of 4 of 10 sq.mm. in PVC pipe with 14 SWG TC wire etc., complete. 158 LANDSCAPING WORK 159 Supply & stacking of red earth at site to the departmental guage for pre-measurements which is of light textured, crystalline, porous and friable and not of generally acidic or neutral but not of alkaline and should be fertile, including seignior age charges, cost of transportation, loading, unloading, stacking and inclusive of all taxes etc., complete. 160 Supply of well decomposed Farm yard Manure in a powdery form, devoid of soil sand, stones, plastics and other materials, highly nutrient and which supports plant growth. 161 Supply and stacking of pit sand / earth filling sand at site to the departmental gauge for pre measurements obtained from sand deposits and should clean without solid particles 162 Mixing charges of Red soil, sand and manure uniformly (1:1:1) for Preparation of soil mixture (excluding material cost) 163 Spreading of red soil, gravel or sand including watering and rolling which hand roller for every 75 mm thickness - including hire charges of roller 164 Preparation of Mounds of various size and shape by availlable excavated/ Supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer - in - charge 165 Planting of Lilly - Hymenocallis Lilly (Spider liiy) shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge 166 Planting of Plumaria Dwarf ornamental foliage Specimen plant variety of height 105- 120 cm in polythene bag of size 16x16 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 167 Planting of Duranta new gold Plant ornamental foliage shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 168 Supplying and Planting of Peltophorum tree sapling of height 240 – 300 cm in polythene bag of size 20x21 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 169 Planting of Bougainvillea Specimen plant variety of height 105-120 cm in polythene bag of size 16x16 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 170 Supplying and Planting of Picharidia palms variety of height 180-210 cm in polythene bag of size 16x16 inch including supporting stack of 5cm dia casurina pole of 10 height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 171 Supplying and Planting of Roystonea regia (Royal palms) palm variety of height 180-210 cm in polythene bag of size 16x16 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 172 Supplying and Planting of Pungam tree sapling of height 240 –300 cm in polythene bag of size 20x21 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge 173 Supplying and Planting of Bauhinia purpurea tree sapling of height 240 – 300 cm in polythene bag of size 20x21 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed bythe site in-charge. 174 Supplying and Planting of Spathodea campanulata tree sapling of height 240 – 300 cm in polythene bag of size 20x21 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in charge. 175 Supplying and Planting of Cane Bamboo tree sapling of height 300 - 360 cm in polythene bag of size 15x16 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge 176 Planting of G2 grass including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 177 CHILDREN PARK AND GYM EQUIPMENTS 178 Supply and fixing of Straight Slide - 7ftLength 450cm ( 15ft ) x Width 75cm ( 2.5ft ) x Height 210cm ( 7ft ) Slide Material : Polyethylene Slide. Slide Length : 21cm ( 7ft ), Slide platform height : 120cm ( 4ft ), Base platform size : 2ft x 2ft, Platform base : Aluminium Checkered Sheet. Center Post : 114mm OD Galvanized post, Side Post : 50mm (2) OD Galvanized post, Powder coating : Electrostatic pp coating on metal parts. Area Required : Length 600cm ( 20ft ) x Width 150cm ( 5ft ) Playing age group : 3 - 10 yrs. Children capacity : 1Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. All fastners closed with polyethylene caps for children protection. 179 Supply and fixing of Park Spiral Slide Junior (FRP)Size: L10.5 x W6 x H7Safe Area Size: L20.5 x W5 x H11.5Material specifications:Ladder : Galvanished ‘B’ Class pipe Sliding chute 9ft BED LEG :Galvanished ‘C’ Class pipeFRP thickness 4mm. (Reinforced Polymers in 5 Layers) 450 CSM Matt, 600 Roving Mat, Isotolic gel coat with PU pigment.ISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball BearingHigh quality Glossy paint with primer 180 Supply and fixing of Cross Swing - 3 Seater Length 390cm ( 13ft ) x Width 120cm ( 4ft ) x Height 225cm ( 7.5ft ) Swing Seat material : LLDPE seats fitted with Stainless steel hooks. Swing Chain : PU coated coated galvanized chain Imported. Swinging Hook : Heavy duty Aluminium pressed with sealed bearing. Swing post : 114mm ( 4.5 ) OD G.I post of wall thickness 2mm, Centre post : 114mm ( 4.5 )OD G.I post of wall thickness 2mm, Playing age group : 3 - 12yrs. Children capacity : 3Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. Swing chain made of PU coated chain , Seat made of LLDPE ( Polyethylene), Swing hooks made of Aluminium with sealed bearings.4. All fastners closed with polyethylene caps for children protection. 181 Supply and fixing of Seesaw - SingleLength 210cm ( 7ft ) x Width 90cm ( 3ft ) x Height 60cm ( 2ft )Seesaw seat material : LLDPE - Polyethylene. Qty : 2Nos.Seesaw center & side post : 89mm ( 3.5 ) OD Galvanized post,Seesaw handle post : 32mm ( 1.2 ) OD Galvanized post,Seesaw post top cap : Heavy duty Aluminium,Powder coating : Electrostatic pp coating on metal parts.Area Required : Length 300cm ( 10ft ) x Width 210cm ( 7ft )Playing age group : 3 - 10yrs.Children capacity : 2Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. All fastners closed with polyethylene caps for children protection. 182 Supply and fixing of Park Seesaw 4 Seater (FRP Seat)Size: L8.75 x W5 x H3 Safe Area Size: L11.75 x W8 x H6 Material specifications:Frame : 1 ½” Galvanished ‘B’ Class pipeSee saw Rail :2” Galvanished ‘C’ Class pipeSeat : FRP Seat with 450 CSM Mat 3 Layers bonding. Isotolic gel coat with UV pigment.Painting with PU coating seatISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball Bearing 183 Supply and fixing of Merry go round - 6 Seater Diameter 180cm ( 6ft ) x Height 75cm ( 2.5ft )Galvanized 50mm dia pipe used for outer ring.Heavy duty Tapper roller bearing setting on the base for smooth rotation.Powder coating : Electrostatic pp coating on metal parts.Area Required : Length 240cm ( 8ft ) x Width 240cm ( 8ft )Galvanized semi circle seats - 2Nos with side saftey handles.Playing age group : 3 - 12yrs.Children capacity : 6Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. All fastners closed with polyethylene caps for children protection. 184 Supply and fixing of Spring Rider - Dinasour Polyethylene Dinasour design attached with 22mm heavy duty coil springs mounted on 10mm Base plate. Metal part powder coated. Safe area - 6ft x 6ft. Playing age group : 3 - 10yrs. Children capacity : 2 Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. All fastners closed with polyethylene caps for children protection. 185 Supply and fixing of Park Loop RungSize: L10 x W2 x H7.5Safe Area Size: L13 x W5 x H10Material specifications:Post-Galvanished ‘B’ Class pipeTop rail-Galvanished ‘C’ Class pipeSprings –Galvanished ‘C’ Class pipe.Painting with PU coating ISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball BearingHigh quality FRP Materials with U~V resistance pigments and ISO Resign and 600 GSM Mat 186 Supply and fixing of Park Flat RotorSize: L5 x W5 x H3.25’ Safe Area Size: L8 x W8 x H6.25Material specifications:Pipes - 1’’GI pipe, 3/4”GI pipe, 3”GI pipe, 2.5mm thick, B class paint: PU coatingISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball BearingHigh quality FRP Materials with U~V resistance pigments and ISO Resign and 600 GSM Mat 187 Supply and fixing of Park Arch Swing 2 Seater (FRP)Size: L10 x W3 x H6.75Safe Area Size: L13 x W6 x H10Material specifications:ARC-Frame : 2.5mm thickness Galvanished ‘B’ Class pipe Top Rail : 2” Galvanished ‘C’ Class pipe with 4.5mm thickSeats : RubberChain : 8mm Stainless Steel Chain (Grade-304)Painting with PU coating ISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball BearingHigh quality FRP Materials with U~V resistance pigments and ISO Resign and 600 GSM Mat 188 Supply and fixing of Air Walker Single personSize: L3.75 x W1.25 x H5 Safe Area Size: L6.75 x W4.25 x H8Material specifications:Main Post made of 4 Inch Pipe and other main pipes 1-1/2 inch Pipes. 3 mm thickness pipes (1680 x 515 x 1780 mm) 4 mm pipe Double coat Powder coating, Heavy duty Branded sealed Ball bearing, for long lasting life. Steel Foot rest / Foot Paddle for long lasting life. 189 Supply and fixing of Chest Press - Single PersonSize: L7.5 x W2.5 x H6Safe Area Size: L10.5 x W5.5 x H9Material specifications:Main Post made of 4 Inch Pipe and other main pipes 1-1/2 inch Pipes. 3 mm thickness pipes. Double coated Powder coating, Heavy duty Branded sealed Ball bearing, Steel & foot rest / Foot Paddle for long lasting life 190 Supply and fixing of Leg Press - Dual PersonDimension : L 120cm ( 4ft ) x W 45cm ( 1.5ft ) x H 130cm ( 4.3ft ) Material : Galvanized Steel. Fastners : Stainless steel 304 grade with Polycaped. Post top Cap : High density Aluminium. Handle grips : HD Rubber coated. Twister Base : Polyethylene. Bearing setting for smooth rotation. Main Post Size : 115mm / 4.5 OD G.I post of wall thickness 3mm. Handle Post Size : 32mm / 1.25 OD G.I post of wall thickness 3mm. Powder coating : 80 micron Akzo nobel electrostatic coated. Area Required : Length 180cm ( 6ft ) x Width 180cm ( 6ft )All Metal posts are made of Galvanized pipes with elecrostatic powder coated. 191 Supply and fixing of Push Up / Pull BarSize: L3.5 x W3.5 x H6.5Safe Area Size: L6.5 x W6.5 x H9.5Material specifications:Main Post made of 4 Inch Pipe and other main pipes 1-1/2 inch Pipes. 3 mm thickness pipes Double coat Powder coating, Heavy duty Branded sealed Ball bearing, for long lasting life. Steel Foot rest / Foot Paddle for long lasting life. 192 Supply and fixing of Shoulder Wheel - Single PersonSize: L2 x W2.5 x H6.25Safe Area Size: 4 x 5.5 x 9.25Material specifications:4mm pipe thick Main Post made of 4 Inch Pipe and other main pipes 1-1/2 inch Pipes. 3 mm thickness pipes Double coat Powder coating, Heavy duty Branded sealed Ball bearing, for long lasting life. 193 Supply and fixing of Excer CycleProduct Dimension : L 85cm ( 2.8ft ) x W 83cm ( 2.7ft ) x H 182cm ( 6.1ft ) Material : Galvanized Steel. Fastners : Stainless steel 304 grade with Polycaped. Post top Cap : High density Aluminium. Rotating Knobs : Polyethylene. Bearing setting for smooth rotation. Main Post Size : 115mm / 4.5 OD G.I post of wall thickness 3mm. Handle Post Size : 32mm / 1.25 OD G.I post of wall thickness 3mm. Powder coating : 80 micron Akzo nobel electrostatic coated. Area Required : Length 180cm ( 6ft ) x Width 180cm ( 6ft )All Metal posts are made of Galvanized pipes with elecrostatic powder coated. 194 Supply and fixing of Lat Pull Down - Single personDimension : L 100cm ( 3.3ft ) x W 75cm ( 2.5ft ) x H 180cm ( 6ft ) Material : Galvanized Steel. Fastners : Stainless steel 304 grade with Polycaped. Post top Cap : High density Aluminium. Handle grips : HD Rubber coated. Seat & Back rest : Polyethylene. Bearing setting for smooth rotation. Main Post Size : 115mm / 4.5 OD G.I post of wall thickness 3mm. Handle Post Size : 50mm / 2 OD G.I post of wall thickness 3mm. Powder coating : 80 micron Akzo nobel electrostatic coated. Area Required : Length 180cm ( 6ft ) x Width 180cm ( 6ft )All Metal posts are made of Galvanized pipes with elecrostatic powder coated. 195 Supply and fixing of Sit Up BoardDimension : L 142cm ( 4.7ft ) x W 112cm ( 3.7ft ) x H 63cm ( 2.1ft ) Material : Galvanized Steel. Fastners : Stainless steel 304 grade with Polycaped. Post top Cap : High density Aluminium. Base material : 25mm OD Galvanized Oval pipes. Post Size : 115mm / 4.5 OD G.I post of wall thickness 3mm. Post Size : 45mm / 1.5 OD G.I post of wall thickness 3mm. Powder coating : 80 micron Akzo nobel electrostatic coated. Area Required : Length 240cm ( 8ft ) x Width 240cm ( 8ft )All Metal posts are made of Galvanized pipes with elecrostatic powder coated. 196 KIOSK 197 ACP KioskSupply of Kiosk: MS Tube Frame Covered with ACP Panel Size: 3m x 2m Bottom: Bison Board 1” Thick Front: Large Door with Double Piston Left Side: Access Window Right Side: Main Door With Lock Top: ACP Sheet (Puff Panel) Table: 7.5Ft x 1.5’ Width 1no Accessories: Fan 1No, Tube light 2Nos, Switch Box 1No, MCP 1No, Exhaust Fan 1No, Wash Basin 1No, Vinyl Flooring, LED Name Board with Logo, Menu Card 198 ELECTRICAL WORKS 199 LT CT TNEB METER BOX: Supply, Installation, testing and commissioning of compartmentalised LT 3Phase, TNEB Metering box of outdoor weather proof type with MS mounting stand, Test Terminal Blocks, Internal control wiring etc., as per local TNEB standards. The box suitable for 3phase 100A service connection made up of with hylem sheet of size 2feet x 1-1/2feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of3Nos.100A fuse units (500V),1No.neutral link,copper earth flat of size1x1/4 with interconnection of EB meter tofuse units by 16 Sq.mm PVC insulated copper wire with suitable necessary connection with earth connection complete. 200 Supply and fixing of 125A TPN Isolator in sheet steel enclosure with double breakon suitable angle iron frame work with MS cable entry boxes with earth connection only. 201 MAIN LT PANEL: Supply, Installation, testing and commissioning of 3Phase, 415Volts, Main LT Panel board of Indoor, Cubicle floor mounting type made out of 2mm thick CRCA Sheet with powder coated finishing, MS base frame, double internal earthing arrangements, 125Amps, rating TPN Copper busbars with interconnection busbar, etc., comprising of the followings:EB Incomer :1 No. 125Amps, 25kA, 4Pole, Thermal magnetic MCCB with Ext.RHOMMetering : 1 Set of RYB LED Indication lamps1 No. of Multifunction Meter with RS 4851 Set of Current Tranformers (125/5A, Cl-1), 1 No. 125/5A CT for APFCR1 Set of Control MCBs Outgoings: 7 Nos. 63Amps, TP+N MCCB 2 Nos. 32Amps, TP+N MCCB3 Nos. 25Amps, DP MCB[Size:2400mm (L) x 350mm (D) x 2000mm(H)] 202 APFCR PANEL - 25KVAR: Supply, Installation, testing and commissioning of 3Phase, 415Volts, 25KVAR rating APFCR (Capacitor) Panel board of Indoor, Cubicle floor / wall mounting type made out of 2mm thick CRCA Sheet with powder coated finishing, MS base /wall frame, double internal earthing arrangements, 63Amps, rating TPN Copper busbars with interconnection busbar, etc., (1 x 10KVAR + 2 x 5KVAR + 1 x 3KVAR + 1 x 2KVAR) 203 12WAY Outdoor Lighting DB - 1 to 5: Supply, Installation, testing and commissioning of Outdoor weather proof type 3Phase Outdoor Lighting DB comprising of 1 No. 63Amps, TP+N, MCCB with Extended RHOM as incomer with RYB LED Phase indication lamps, 3Phase 63Amps, 4Pole Timer internal control wiring, etc., Outgoings: 11 Nos. 16A-32Amps, 4P MCBs &3 Nos. 20Amps, DP MCBs including Copper busbar connections, interconnection cables, cable entry provisions, floor mounting frame (600mm to 900mm), etc., 204 SLDB-1 to 4 and ELV UPS DB: Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1no. 32A DP MCBswitch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wallwith earth connection only.Higher End 205 Pump room DB - 1 & 2: Supply and fixing of 8 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB switch as incoming and 5 nos. 32A 3P MCB, 9 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End 206 SupplyandLayingof31/2 Corex120 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 207 SupplyandLayingof31/2 Corex70 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good 208 SupplyandLayingof31/2 Corex50 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 209 SupplyandLayingof31/2 Corex95 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 210 SupplyandLayingof31/2 Corex25 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 211 Supply and Clamping of 2 core x 10 Sq.mm PVC armoured LTUGaluminium cable on post or on wall MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable. 212 Supply and fixing of brass cable gland for 2 x 10 sq.mm. PVC armoured LTUG cable with earth connection 213 Supply and fixing of brass cable gland for 3-1/2 x 25 sq.mm. PVC armoured LTUG cable with earth connection 214 Supply and providing cable end termination of 3-1/2 x 25 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 215 Supply and fixing of brass cable gland for 3-1/2 x 50 sq.mm. PVC armoured LTUG cable with earth connection 216 Supply and providing cable end termination of 3-1/2 x 50 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 217 Supply and fixing of brass cable gland for 3-1/2 x 70 sq.mm. PVC armoured LTUG cable with earth connection 218 Supply and providing cable end termination of 3-1/2 x 70 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 219 Supply and fixing of brass cable gland for 3-1/2 x 95 sq.mm. PVC armoured LTUG cable with earth connection 220 Supply and providing cable end termination of 3-1/2 x 95 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 221 Supply and fixing of brass cable gland for 3-1/2 x 120 sq.mm. PVC armoured LTUG cable with earth connection 222 Supply and providing cable end termination of 3-1/2 x 120 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 223 Supply and erection of GIHotDip/PowderCoated16SWGPerforated type CableTraywith 300mm width and 50mm height with all the fixing accessories 224 Supply and Run of 2 of 2.5 sq.mm.PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable gauge MS conduit pipe Concealed inwall and ceiling with continuous earth wire connection of 2.5 sq mm copperwire and making good of the concealed portion 225 Supply and Run of 2 of 6 sq.mm.PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable gauge MS conduit pipe concealed inwall and ceiling with continuous earth wire connection of 6 sq mm copperwire with painting of suitable colour. 226 Supply andrunof2 of4 sq.mm. PVC insulatedSC unsheathedFRLS copperconductorof1100V gradeinsuitable heavy gauge MS conduit pipe concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm copper wire and making good of the concealed portion wiith suitable colour 227 Supply and fixing of 1 no.6A two module 5 pin socket , 1 no.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 228 Supply and fixing of 2nos.6A two module 5 pin socket , 2 nos.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 229 Supply and fixing of 1 no.6/16A two modulesocket , 1 no.16A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 230 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End (Primary) 231 Supply and fixing of 18W LEDRound type Recessedfitting with LED (Higher end) on false Ceiling from ceilingwith PVC unsheathed copper leads from terminals to the fitting. 232 Supply and erection of 20Watts, 4 Feet LED Fitting with LED (Higher end) end cap, PVC unsheathed copper leads from terminals to the fitting and fixing accessories 233 Supply and fixing of 60Watts All-in-One (AIO) Model Solar Street Light with 6000mm Height pole with base plate and all the fixing accessoriesThe cost is inclusive of civil foundation works including anchor fasteners,etc., as per site requirements 234 Supply and fixing of 3W RGB Light fitting (IP67) Inground fixture with PVC unsheathed copper leads from terminals to the fitting and to complete necessary accessories and etc to complete the work. KLITE:4092 - symmetrical Inground 235 Supply and fixing of spike light 6W fitting on floor with PVC unsheathed copper leads from terminals to the fitting and to complete necessary accessories and etc to complete the work. KL-Trioscope - 7052 236 Supply of One No of 9.5 mtr. Street Lamp Post With 2.7 mtr Arch Double Bracket, 1 No. of 4 Core SMC Fuse Box With Hot Dip Zinc Galvanising 237 Cost of Erection & Materials Required For 9.5 mtr Street Lamp Pole With Brackets Conventional Foundation(Material Ratio - 1:1.5:3) 238 Supply and fixing of 300mm (12) sweep(Heavy Duty) AC exhaust fan complete with necessary wall opening and making good of the wall . 239 Supply and fixing of MS / Fibre Louvers Shutters arrangements for 300mm ACExhaust Fan (M-1346) 240 Supply and fixing of 1200mm (48) sweep AC ceiling fan 5 star ratedcomplete ( Higher end)with 2 module 100W fan step regulator (Higher end)with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18) 241 Supply and fixing of Maintenance Free earthing with Copper rod of 17.2 mm dia and 3m length including all the civil works 242 Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection 243 Supply and Run of1 of No.8 SWG copper wire for earth connection 244 Supply and Run of1 of No.8 SWG copper wire in suitable PVC rigid pipeon wall / floor / ground for earth connection 245 Supply of 2mx1mRubberMatsuitablefor11KVinstallation confirming to IS 246 Supply of First Aid Box complete with all First Aid Medicines 247 Supply and fixing of Shock Treatment chart with Glass frame(in English & Local Language) 248 Supply and fixing ofMetallic Danger Board as required by the Electrical Authorities (415Volts & 230Volts) 249 Supply and Installation for 2KVA, UPS (Single Phase Input & Single Phase Output) Capacity with 2Hourse Battery back up, battery stand and interconenction cables. 250 Supply and fixing of 40Amps, 30mA DP RCCB in a suitable sheet steel enclosure and necessary fixing accessories (Higher end) 251 CCTV SYSTEM 252 Supply, Installation, Testing and commissioning of 32 channel 8 SATA NVR, with 10TB Hard Disk Drive 2 nos, New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected,Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output  HDMI1 / VGA1 outputs provided  HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface for HDD connection, Support upto 10TB capacity for each HDD, Smart search for efficient playback. and smart playback to improve the playback efficiency, Supports VCA search for fire/ship/temperature/temperature difference detection triggered video files, POS information overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access  Hik-Connect for easy network management, 2 Gigabit Ethernet network interfaces. 253 Supply of 4MP, Internet Protocol fixed BULLET CAMERA (OUTDOOR) with following specification:a) 1/2.5 Progressive Scan CMOS, b) 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behavior analyses ( Line crossing detection, intrusion detection)c) Face Detection d) 120dB WDR, e) BLC/3D DNR/ROI, IP67 compliedff) On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,g) Shutter Speed 1/3 s to 1/100,000 s, h) 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, i) rotate: 0° to 360°, 2.8 mm, j) horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, k) Lens Mount M12 & IR Range I5: up to 50 m, l) Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, m) Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9Wn) Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse. with Camera Stand. 254 Supply of 8MP, Internet Protocol fixed BULLET CAMERA with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behavior analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse with suitable Stand. 255 Supply, Installation, Testing and Commissioning of 55 smart LED TV with following specifications a) Resolution: Ultra HD (4K) 3840 x 2160b) IPS panel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -2nos n) Built in LAN o) Magic remote 256 Supply and Clamping of CAT 6 unarmoured cable in suitable PVCPipe 1 thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem)i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal)IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-TIEEE 802.5 16 MB; ISDN; TPDDI; ATMii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant.Fire Rating: PVC : IEC 60332-1.iii. Conductor - Bare Copper Wireiv. Insulation - Polyethylene v. Twisting - 2 Cores to the pair vi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm. 257 Supply and laying of armoured, Multimode, Thermoplastic Tape Inner Sheathed, PVC type sheathed 6 core Optical Fibre Cable withunique fiber excess length control method provides the cable with excellent mechanical and environmental properties and Cable - 2 Embedded FRP provides tensile strength & Anti-buckling properties. It is processed with Filling jelly - Thixotropic jelly to prevent Water ingress in loose tube. 258 Supply and Termination of Optical Fibre Cable Single Point ( Point to Point ) Splicing and arrangement charges. 259 Supply and fixing of POE 8port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. 260 Supply and Fixing of Rack with Accessories -Higher end6U Rack with fan extra for the above rack. (speaker/data/cctv) 261 Supply and fixing of POE 24 port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. 262 Supply, Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point ( Point to Point ) Crimping, Testing and arrangement charges. 263 Supply and fixing of outdoor 4X6PVC box with 102mmX77mmX102mm with all fixing accessories. 264 Supply and Erection of 6mtrLengthpole with base plate of size 300x300x12mm as per IS-875 with following specification. Pole Outter dia -76.10mm x 3.65mm Thick x 6 meter with foundation Charges.The Pole Should be hot dip Galvanized confirming to BESN ISO-1461 with thickness of 65 Micron 265 PA SYSTEM 266 Supply, Installation,Testing & commisioning of 30 watts 2 way high efficiency, high fidelity, long throw IP65 weather proof P.A Music Horn WALL / COLUMN speaker. It combines the high efficiency of horn with wide frequency response.Music horn is weather protected and UV protected ABS plastic housing combines with the feature of easy poertap selection on a terminal strip with a two core cable.It has impedence of 250/500/1k/2k ohm with frequency response of 120-16000 hertz. 267 Supply, Installation,Testing & commisioning of 480 watts P.A Booster Amplifier with the output power of 1350 watts maximum, 500watt rms at 10% Thyristor harmonic distortion(THD), 850watt RMS at 5% THD, 800 wattsRMS at 2% THD and the power supply AC voltage ranging from 220-240 volt, 50/60 hertz. with the DC input of 48 volt and 1000watts has tone controls of Bass=+- 10 db at 100 hz weighing 42kg with the speaker output of2Q,4Q.70volt&100volt has power consumption of 1600VA AC &12A DC and 100db output regulation at 1khz no load to full load ratio. The signal to noise ratio is 60db with the imnput channels of 0.8mv/4.7kq,3*Aux 100mv/50kq.The frequency response of 50-15000hz+-3db. 268 Supply, Erection,testing & Commisioning of custom built table top 4 zone micro processor based 1 way announcement console cinsisting of teleline preamplifier , 1 x priority module , 12 zone selector module , all call switch module , tone oscilator modulefor fire evacation, press to talk switch module,goose neck microphone ,24v dc rectifier module, power supply uit , all call relay module etc as required.(Delegate unit) 269 Supply and Fixing of Rack with Accessories -Higher end6U Rack with fan extra for the above rack. (speaker/data/cctv) 270 Supply, run, testing and commissioning of2Core x 1.5sq sqmm PVC insulated Armoured Speaker Cable in suitable 25mm dia Pvc Rigid pipe concealed on wall and ceiling with continuous earth wire connection with painting of suitable colour.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
29.
Educational and Research Institute #10184256 Price Bid
Tender For Purchase Of Books And Journals At Lady Barbouren College-- 1 List Of Books : Zoology 2 Developmental Biology ( 12Th Edition ) 3 Cellular And Molecular Immunology ( 10Th Edition ) 4 Kuby Immunology ( 8Th Edition ) 5 Wilson And Walker’S Principles And Techniques Of Biochemistry And Molecular Biology ( 8Th Edition ) 6 Molecular Biology ( 5Th Edition ) 7 List Of Books : Economics 8 1 David G.Luenberger 9 F. S. Mishkin And S. G. Eakins, 10 F. J. Fabozzi, F. Modigliani, F. J. Jones, M. G. Ferri, 11 Panchanan Das 12 List Of Books : Urdu 13 Tarikh-E-Adaburdu 4 Volumes 4 Set 14 Urdu Afsanekirawayat 2 Volumes Set 15 Adbitahrikat-O- Rujahanat 16 Fikr-O-Shaur 17 Zafar Uganvibichkawaraqketanazurmein 18 List Of Books : History 19 World Prehistory : A New Perspective 20 Early Social Formations 21 The Cambridge History Of China, Vol.X 22 A History Of Modern Japan 23 The Eighteenth Century In Indian History : Evolution And Revolution 24 Women In Early Indian Societies 25 A Cultural History Of India 26 Iron & Social Change In Early India 27 Bharat Itihaser Adiparba ( 2Nd Part ) 28 Europe Yugantar 29 List Of Books : Political Science 30 Quarter Century Of Liberalisation In India 31 Coalition Politics In India 32 Political Economy Of Reforms In India 33 Fifty Key Thinkers In International Relations 34 Rethinking Public Institutions In India 35 Panchayati Raj 36 Indian Administration: Evolution And Practice 37 International Politics: Concepts, Theories And Issues 38 Does The Elephant Dance? Contemporary Indian Foreign Policy 39 Public Policy In India 40 List Of Books : English 41 A Guide To The Plays Of Bertolt Brecht 42 Black On Black: Twentieth Century African American Writing About Africa 43 Map Making: Partition Stories From 2 Bengals 44 The Other Side Of Silence : Voices From The Partition Of India. 45 Adventure, Mystery And Romance: Formula Stories As Popular Culture, New Edition. 46 Cambridge Companion To Crime Fiction, 47 The Dialogic Imagination: Four Essays Press, 1981. 48 Through The Looking Glass - Worldview Critical Edition, January 2014, 49 The Theatre Of The Absurd 50 Stephen FryeS Greek Myths: Set Of 3 Books - Mythos, Heroes, Troy.. 51 List Of Books : Mathematics 52 Differentiall Geometry 53 Elementary Differential Geometry 54 Intrduction To Partial Differential Equations , Phi, Third Edition, 2015 55 R Programming And Sage Math 56 Introduction To The Theory Of Graph 57 Computer Analysis 2Nd Edi. Undergraduate Test In Mathematics 58 An Introduction To Complex Analysis 59 Computer Analysis In One Variable 60 Linear Algebra 61 T.W. Hangerford Algebra 62 List Of Books : Botany 63 Text Book Of Palynology 64 Pollen Morphology & Plant Taxonomy 65 Mushroom Cultivation Technology, 2020 66 Mushroom Cultivation 67 Handbook Of Mushrooms, Ed. Ii, Vol I & Vol Ii 68 The Evolution Of Plants. 2Nd Edition 69 Fundamentals Of Ecology 70 Essentials Of Ecology And Environmental Science 71 List Of Books : Hindi 72 Manas Ka Rajhans 73 Mrignayani 74 Gaban 75 Tyagpatra 76 Mahabhoj 77 Anuvad Vigyan Ki Bhumika 78 Anuvad Vigyan:Siddhant Aur Pravidhi 79 Pratinidhihindi Nibandhkar 80 Bhartiya Kavyashastra Ki Bhumika 81 Bhasha Vigyan Ki Bhumika 82 Vigyapan Bhasha Aur Sanrachana 83 List Of Books : Geography 84 Surveying & Levelling Vol - I And Vol 2 85 Coastal Zone Management 86 Fieldwork In Geography 87 Fieldwork For Human Geography 88 Statistics For Geography And Environmental Science 89 Statistics For The Social Sciences 90 Rivers Of The Ganga-Brahmaputra-Meghna Delta: A Fluvial Account Of Bengal ( Geography Of The Physical Environment ) 91 Bharatiya Sundarban 2021 Bengali Edition 92 Environmental Geography 93 Oceanography 94 Mrittika Porichaya ( Bangla ) 95 List Of Books : Physics 96 Quantum Physics 97 Arduino Cookbook , Latest Edition 98 Introduction To Quantum Mechanics 99 Basic Solid State Physics 100 Elements Of Nonequillibrium Statistical Mechanics 101 List Of Books : Statistics 102 Nonparametric Methods In Statistics 103 Nonparametric Statistical Inference 104 Statistical Methods For Survival Data Analysis ( Third Edition ) 105 Survival Analysis 106 Research Methodology: Methods And Techniques ( Second Revised Education ) 107 A Guide To Research Methodology 108 Elements Of Large Sample Theory 109 Exploring Monte Carlo Methods 110 List Of Books : Sociology 111 Contemporary Sociological Theory: Expanding The Classical Tradition. 112 Colonialism And Its Forms Of Knowledge. 113 Social Stratification 114 Sex Selective Abortion In India: Gender. Society And New Reproductive Technologies 115 Rural Development In India 116 Introduction To Rural Sociology 117 Rural Development System 118 What Is Patriarchy? 119 List Of Books : Computer Science 120 Designing A Webpage Using Html Fundamentals 121 Let Us C ( 19Th Ed. ) 122 Data Structure Design Using C ( 2Nd Ed. ) 123 Digital Design: With An Introduction To The Verilog Hdl, Vhdl And System Verilog ( 6Th Ed. ) 124 Computer Architecture And Organization ( 3Rd Ed. ) 125 Digital Circuits, Vol - I & Ii 126 Programming In Ansi C ( 8Th Ed. ) 127 Introduction To Computation And Programming Using Python 128 Unix Shell Programming 129 Think Python: How To Think Like A Computer Scientist 130 List Of Books - ( Science & Arts ) : Library 131 I Gentics 132 Quantum Theory Of Solids 133 Fundamental Of Applied Statistics 134 Biostatistics 135 Optics, Futures And Other Derivatives 136 Endocrinology 137 Introduction To General Zoology 138 Nuclear Physics 139 Biodiversity 140 Practical Geography : A Systematic Approach 141 Advances In Remote Sensing And Gis Analysis 142 Financial Markets And Institution 143 Indian Polity 144 Organic Chemistry 145 An Advanced Laboratory Of Zoology 146 Organic Evolution 147 Electricity And Magnetism 148 Optics 149 Fundamentals Of Geographical Thought 150 Probability And Statistics 151 Evolution Of Geographical Thought 152 Inorganic Chemistry 153 Public Finance 154 Surveying And Levelling 155 Macro Economics Of Past Reform India 156 Statistical Tools And Techniques 157 Differential Geometry 158 A Source Book In Astronomy And Astrophysics, 1900-1975 159 Endocrinology 160 Open Economy Macroeconomics 161 Artificial Intelligence : A Modern Approach 162 Artificial Intelligence For Dummies 163 Machine Learning For Absolute Beginners : A Plain English Introduction 164 Major Government 165 Bharatiya Dharmaniti 166 International Relation 167 Indian Govt. And Politics 168 The Murder Of Roger Ackroyed 169 Modern Prose 170 Wise & Otherwise 171 List Of Books : Chemistry 172 Inorganic Chemistry, 173 Mechanism And Theory In Organic Chemistry 174 Boranes In Organic Chemistry 175 An Introduction To Medicinal Chemistry 176 Workbook For Organic Synthesis The Disconnection Approach 177 Sulfur Chemistry 178 Heterocyclic Chemistry 179 Selected Experiments In Physical Chemistry 180 Quantum Mechanics Concepts And Applications 181 Advanced Experiments In Inorganic Chemistry 182 VogelS Qualitative Inorganic Analysis ( 7Th Edition ) 183 List Of Books : Women Studies 184 Understanding Gender 185 What Is Patriarchy? 186 Gendering Caste: Through A Feminist Lens 187 Patriarchy : Theorising Feminism 188 Seeing Like A Feminist 189 Human Rights In India: Theory And Practice 190 Women’S Studies In India : A Reader 191 List Of Books : Persian 192 A Comprehensive Persian-English Dictionary: Including The Arabic Words And Phrases To Be Met With In Persian Literature 193 A Grammar Of The Persian Language 194 A Short History Of Persian Literature: At The Bahmani, The Adilshahi And The Qutbshahi Court-Deccan 195 Biographical Dictionary Of Sufism In South Asia 196 Central Asia In The Sixteenth Century 197 Perso-Arabic Hybrids In Hindi: The Socio-Linguistic And Structural Analysis 198 Studies In Early Modern Indo-Aryan Langauges, Literature And Culture 199 The Forgotten Mughals: A History Of The Later Emperors Of The House Of Babar ( 1707-1857 ) 200 The Gulistan Of Shaikh SaDi Shirazi 201 List Of Books : Microbiology 202 Principles Of Genetics, 8Th Ed, 2008 203 Concepts Of Genetics, 10Th Ed, 2012 204 Genomes 2018 4Th Ed. 205 I-Genetics – A Molecular Approach. 3Rd Ed, 2009 206 Genetics Analysis Of Genes And Genomes 7Th Ed 2009 207 Statistical Methods, Combined Edition ( Vol I And Ii ) 2013 208 Ecology And Environment, 13Th Ed, 2017 209 Ipr, Biosafety And Bioethics 2013 210 Introduction To Modern Virology7th Edition2016 211 Genetics. 3Rd Ed. 1997. 212 List Of Books : Philosophy 213 Tarkasangrahadipika On Tarkasangraha 214 Tarkasangraha By Annambhatta 215 Introduction To Logic, 13Thed 216 An Introduction To Philosophical Analysis 217 Ethics Integrity And Aptitude 218 Women In Indian Society 219 Personality Psychology 220 Pashchatya Darshaner Ruprekha 221 Bharatiya Darshan 222 Darshanik Bishleshaner Ruprekha 223 List Of Books : Bengali 224 Kabitar Chhanda Chhander Kabita 225 Jagari 226 Kapalkundala ( Edited By Khetra Gupta ) 227 Krishnakanter Will ( Edited By Arup Kumar Das ) 228 Krishnakanter Will ( Edited By Dhrubakumar Mukhopadhyay ) 229 Premendra Mitrer Shreshtha Galpo 230 Banapfuler Shreshtha Galpo 231 Sanskrita Sahityer Ruprekha 232 Sahitya Bibek 233 Aboshyik Bangla 234 Jogajog 235 Dipendranath Bandhyopadhayer Shrestha Galpo 236 Bangla Choto Galper Bish Shatak 237 Bangla Sahitye Hasyo Ros 238 Sanga Nisanga Rabindranath 239 Rabindra Sahitya Pather Bhumika 240 Kabi Rabindranath 241 Bangla Kabya Sangeet O Rabindra Sangeet 242 List Of Journals : Library 243 Indian Historical Review 244 Indian Journal Of Gender Studies 245 Indian Journal Of Chemistry ( Part– A & Part-B ) 246 Journal Of Interdisciplinary Economics 247 International Journal Of Biotechology & Biochemistry / Research India 248 Urbanisation 249 International Journal Of Enviornmental Research & Development 250 Science, Techonology & Society 251 Studies In Indian Politics 252 International Journal Of Biology Research 253 International Journal And Environmental & Ecology Research 254 International Journal Of Sanskrit Research 255 Resonance 256 Arab Journal Of Mathematics And Mathematical Science 257 Advance Science In Algebra 258 Korok Sahitya Patrika 259 Indian Literature / Sahitya Academy 260 Indo Iranica 261 Fikr-O-Tahrir
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 6
West Bengal View Result →
30.
Power #10172978 AOC
Tender For Annual Maintenance Repair Of Md Dvvnl Office Vidyut Adhikari Colony At 220 Kv Sub Station, Sikandra, Agra - Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: (DSR 2.1) All kinds of soil (DSR 2.1.1) 2 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. (DSR 2.6) All kinds of soil (DSR 2.6.1) 3 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.(DSR 2.8) All kinds of soil. (DSR 2.8.1) 4 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. (DSR )(DSR 2.25) 5 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. (DSR )(DSR 2.25(a)) 6 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. (DSR 2.26) All kinds of soil (DSR 2.26.1) 7 Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. (DSR )(DSR 2.27) 8 Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. (DSR 2.28) All kinds of soil (DSR 2.28.1) 9 Ploughing the existing ground to a depth of 15 cm to 25 cm and watering the same. (DSR 2.29) All kinds of soil (DSR 2.29.1) 10 Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil, as directed within a lead of 50 m and lift upto 1.5 m. (DSR 2.3) All kinds of soil (DSR 2.30.1) 11 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. (DSR )(DSR 2.31) 12 Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. (DSR )(DSR 2.32) 13 Supplying chemical emulsion in sealed containers including delivery as specified. (DSR 2.34) Chlorpyriphos/ Lindane emulsifiable concentrate of 20% (DSR 2.34.1) 14 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (DSR 2.35) Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: 2.35.1 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration (DSR 2.35.1.1) 15 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (DSR 2.35) Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: 2.35.2 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration (DSR 2.35.2.1) 16 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (DSR 2.35) Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: 2.35.3 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration (DSR 2.35.3.1) 17 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (DSR 2.35) Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : 2.35.4 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration (DSR 2.35.4.1) 18 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (DSR 2.35) Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same. (DSR 2.35.5) 19 Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge. (DSR )(DSR 2.36) 20 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.1.2) 21 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.1.3) 22 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) (DSR 4.1.8) 23 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:5:10 (1 cement : 5 fine sand derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) (DSR 4.1.11) 24 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR 4.2.2) 25 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.2.3) 26 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:2:4 (1 Cement : 2 coarse sand (zone-III)including manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 25% : 4 graded stone aggregate 20 mm nominal size including Recycled Concrete Aggregate (RCA) upto 25%)). (DSR 4.2.3A) 27 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources). (DSR 4.2.8) 28 Centering and shuttering including strutting, propping etc. and removal of form work for : (DSR 4.3) Foundations, footings, bases for columns (DSR 4.3.1) 29 Centering and shuttering including strutting, propping etc. and removal of form work for : (DSR 4.3) Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. (DSR 4.3.2) 30 Centering and shuttering including strutting, propping etc. and removal of form work for : (DSR 4.3) Columns, piers, abutments, pillars, posts and struts (DSR 4.3.3) 31 Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. (DSR 4.4) 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.4.1) 32 Providing and fixing up to floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc., including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required Centering complete. (DSR 4.5) 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources) (DSR 4.5.1) 33 Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. (DSR 4.6) 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR 4.6.1) 34 Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete : (DSR 4.7) 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR 4.7.1) 35 Precasting and placing in position 125 mm dia Bollards 600 mm high of required shape including providing M.S. Pipe Sleeve 50 mm dia 300 mm long in the Bollard and M.S. Pipes 40 mm dia and 450mm long with 150x150x6mm M.S. plate welded at bottom and embedded 150mm in cement concrete 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources), including necessary excavation of size 250x250x450mm deep for the same in bitumen/concrete pavement at specified spacing. (DSR )(DSR 4.9) 36 Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources).(DSR )(DSR 4.11) 37 Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturers specification. (DSR )(DSR 4.12) 38 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (DSR 5.1) C (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 5.1.2) 39 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : (DSR 5.2) 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 5.2.2) 40 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.3) 41 Providing and laying reinforced cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.4) 42 Reinforced cement concrete work in arches, archribs, domes, vaults, shells, folded plate and roofs having slope more than 15° up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.5) 43 Reinforced cement concrete work in chimneys, shafts, up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.6) 44 Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources). (DSR )(DSR 5.8) 45 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Foundations, footings, bases of columns, etc. for mass concrete (DSR 5.9.1) 46 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. (DSR 5.9.2) 47 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Suspended floors, roofs, landings, balconies and access platform (DSR 5.9.3) 48 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Shelves (Cast in situ) (DSR 5.9.4) 49 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Lintels, beams, plinth beams, girders, bressumers and cantilevers (DSR 5.9.5) 50 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Columns, Pillars, Piers, Abutments, Posts and Struts (DSR 5.9.6) 51 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Stairs, (excluding landings) except spiral-staircases (DSR 5.9.7) 52 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Chimneys and shafts (DSR 5.9.11) 53 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards(DSR 5.9.13) 54 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like (DSR 5.9.15) 55 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Edges of slabs and breaks in floors and walls 5.9.16 Under 20 cm wide (DSR 5.9.16.1) 56 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Weather shade, Chajjas, corbels etc., including edges (DSR 5.9.19) 57 Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.12) 58 Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5m clear span up to floor five level, including the cost of required centering, shuttering but , excluding the cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.13) 59 Providing, transporting, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in lintels, beams and bressumers, including setting in cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering and shuttering but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR )(DSR 5.15) 60 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (DSR 5.22) Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22.6) 61 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. (DSR 5.22A) Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22A.6) 62 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1) Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.1.1) 63 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1) Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.1.2) 64 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (DSR 6.4) Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.4.1) 65 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (DSR 6.4) Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.4.2) 66 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. (DSR 6.13) Cement mortar 1:4 (1 cement :4 coarse sand) (DSR 6.13.2) 67 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble 8.2.1 Area of slab upto 0.50 sqm (DSR 8.2.1.1) 68 (DSR 8.2) Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble 8.2.1 Area of slab over 0.50 sqm (DSR 8.2.1.2) 69 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Granite stone slab of colour black, Cherry/Ruby red 8.2.2 Area of slab upto 0.50 sqm (DSR 8.2.2.1) 70 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Granite stone slab of colour black, Cherry/Ruby red 8.2.2 Area of slab over 0.50 sqm (DSR 8.2.2.2) 71 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Granite stone slab of all colour and texture except black, Cherry/Ruby red 8.2.3 Area of slab over 0.50 sqm (DSR 8.2.3.2) 72 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. (DSR 8.3) Granite work (DSR 8.3.2) 73 Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. (DSR )(DSR 8.4) 74 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. (DSR )(DSR 8.5) 75 Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. (DSR )(DSR 8.6) 76 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : (DSR 8.14) Red sand stone - exposed face fine dressed with rough backing. 8.14.1 30 mm thick (DSR 8.14.1.5) 77 Providing and fixing plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with : (DSR 8.28) Decorative veneer facings of approved manufacture (DSR 8.28.1) 78 Providing and fixing skirting with Pre-laminated (one side decorative and other side balancing lamination) flat pressed 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete : (DSR 8.3) 18 mm thick (DSR 8.30.1) 79 Providing and fixing skirting with Pre-laminated (one side decorative and other side balancing lamination) flat pressed 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete : (DSR 8.3) 25 mm thick (DSR 8.30.2) 80 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (DSR )(DSR 8.31) 81 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. (DSR )(DSR 8.32) 82 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (DSR 9.1) Sal wood (DSR 9.1.2) 83 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hingesand necessary screwsshall be paid separately) (DSR 9.5) Second class teak wood 9.5.1 35 mm thick shutters (DSR 9.5.1.1) 84 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hingesand necessary screwsshall be paid separately) (DSR 9.5) Second class teak wood 9.5.1 30 mm thick shutters (DSR 9.5.1.2) 85 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : (DSR 9.7) Second class teak wood (DSR 9.7.1) 86 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. (DSR 9.9) Second class teak wood 9.9.1 35 mm thick (DSR 9.9.1.1) 87 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. (DSR 9.9) Second class teak wood 9.9.1 30 mm thick (DSR 9.9.1.2) 88 Extra for providing heavy sheet float glass panes instead of ordinary float glass in glazed doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured) (DSR 9.11) 5.0 mm thick(weight not less than 12.50 kg per sqm) instead of 4 mm thick(weight not less than 10 kg per sqm). (DSR 9.11.1) 89 Extra for providing frosted glass panes 4 mm thick (weight not less than 10 kg per sqm) instead of ordinary float glass panes 4 mm thick(weight not less than 10 kg per sqm) in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). (DSR )(DSR 9.12) 90 Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured). (DSR )(DSR 9.14) 91 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 9.16) Panelled or panelled & glazed shutters : 9.16.1 Second class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws (DSR 9.16.1.2) 92 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 9.16) Glazed shutters : 9.16.2 Second class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws (DSR 9.16.2.2) 93 Providing and fixing flat pressed three layer particle or gradedplain wood board medium density exterior grade (Grade I) FPT-I, conforming and markedto frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): (DSR 9.17) 12 mm thick (DSR 9.17.1) 94 Providing and fixing flat pressed three layer particle or gradedplain wood board medium density exterior grade (Grade I) FPT-I, conforming and markedto frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): (DSR 9.17) 18 mm thick (DSR 9.17.2) 95 Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). (DSR 9.18) 18 mm thick (DSR 9.18.1) 96 Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). (DSR 9.18) 25 mm thick (DSR 9.18.2) 97 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (DSR 9.2) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.20.1) 98 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (DSR 9.2) 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.20.2) 99 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (DSR 9.2) 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws (DSR 9.20.3) 100 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (DSR 9.21) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.21.1) 101 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (DSR 9.21) 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.21.2) 102 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (DSR 9.21) 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws (DSR 9.21.3) 103 Extra if louvers (not exceeding 0.2 sqm) are provided in flush door shutters (overall area of door shutters to be measured). (DSR 9.25) Decorative type door (DSR 9.25.1) 104 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). (DSR )(DSR 9.26) 105 Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :35 mm thick shutters (DSR 9.27.1) with ISI marked M.S. pressed butt hinges bright finished of required size 9.27.1.1 Second class teak wood (DSR 9.27.1.1.1 ) 106 Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :35 mm thick shutters (DSR 9.27.1) With ISI marked stainless steel butt hinges of required size 9.27.1.2 Second class teak wood (DSR 9.27.1.2.1) 107 Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :30 mm thick shutters (DSR 9.27.2) with ISI marked M.S. pressed butt hinges bright finished of required size 9.27.2.1 Second class teak wood (DSR 9.27.2.1.1) 108 Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :30 mm thick shutters (DSR 9.27.2) With ISI marked stainless steel butt hinges of required size 9.27.2.2 Second class teak wood (DSR 9.27.2.2.1) 109 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : (DSR 9.4) 2nd class teak wood 9.40.1 50x12 mm (DSR 9.40.1.1) 110 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : (DSR 9.4) 2nd class teak wood 9.40.1 50 x 20 mm (DSR 9.40.1.2) 111 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : (DSR 9.4) Kiln seasoned and chemically treated hollock wood 9.40.2 50x12 mm (DSR 9.40.2.1) 112 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : (DSR 9.4) Kiln seasoned and chemically treated hollock wood 9.40.2 50x20 mm (DSR 9.40.2.2) 113 Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : (DSR 9.47) 20 mm dia (heavy type) (DSR 9.47.1) 114 Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : (DSR 9.47) 25 mm dia (heavy type) (DSR 9.47.2) 115 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. (DSR 9.48) Fixed to steel windows by welding (DSR 9.48.1) 116 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. (DSR 9.48) Fixed to openings /wooden frames with rawl plugs screws etc. (DSR 9.48.2) 117 Providing and fixing ISI marked, IS : 1341, M.S. heavy weight bright finished butt hinges with necessary screws etc. complete : (DSR 9.56) 125x90x4.00 mm (DSR 9.56.1) 118 Providing and fixing ISI marked, IS : 1341, M.S. heavy weight bright finished butt hinges with necessary screws etc. complete : (DSR 9.56) 100x75x3.50 mm (DSR 9.56.2) 119 Providing and fixing ISI marked, IS : 1341, M.S. heavy weight bright finished butt hinges with necessary screws etc. complete : (DSR 9.56) 75x60x3.10 mm (DSR 9.56.3) 120 Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 125x65x2.12 mm (DSR 9.57.1) 121 Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 100x58x1.90 mm (DSR 9.57.2) 122 Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 75x47x1.70 mm (DSR 9.57.3) 123 Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.59) 150 mm (DSR 9.59.1) 124 Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.59) 125 mm (DSR 9.59.2) 125 Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.59) 100 mm (DSR 9.59.3) 126 Providing and fixingISI marked IS: 453 oxidised M.S. double acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.6) 150 mm (DSR 9.60.1) 127 Providing and fixingISI marked IS: 453 oxidised M.S. double acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.6) 125 mm (DSR 9.60.2) 128 Providing and fixingISI marked IS: 453 oxidised M.S. double acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.6) 100 mm (DSR 9.60.3) 129 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.62) 300x16 mm (DSR 9.62.1) 130 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.62) 250x16 mm (DSR 9.62.2) 131 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 250x10 mm (DSR 9.63.1) 132 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 200x10 mm (DSR 9.63.2) 133 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 150x10 mm (DSR 9.63.3) 134 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 100x10 mm (DSR 9.63.4) 135 Providing and fixing ISI marked 85x42 mm oxidised M.S. pull bolt lock conforming to IS : 7534 with necessary screws bolts, nut and washers etc. complete (Copper oxidised as per IS 1378). (DSR )(DSR 9.64) 136 Providing and fixing ISI marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.65) 300x20x6 mm (DSR 9.65.1) 137 Providing and fixing ISI marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.65) 250x20x6 mm (DSR 9.65.2) 138 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 125 mm (DSR 9.66.1) 139 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 100 mm (DSR 9.66.2) 140 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 75 mm (DSR 9.66.3) 141 Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.67) 150 mm (DSR 9.67.1) 142 Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.67) 115 mm (DSR 9.67.2) 143 Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.67) 90 mm (DSR 9.67.3) 144 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : (DSR 9.7) 125x64x1.90 mm (DSR 9.70.1) 145 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : (DSR 9.7) 100X58X1.90 mm (DSR 9.70.2) 146 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : (DSR 9.7) 75x47x1.80 mm (DSR 9.70.3) 147 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : (DSR 9.7) 50x37x1.50 mm (DSR 9.70.4) 148 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : (DSR 9.71) 125x64x2.50 mm (DSR 9.71.1) 149 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : (DSR 9.71) 100x60x2.50 mm (DSR 9.71.2) 150 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : (DSR 9.71) 75x50x2.50 mm (DSR 9.71.3) 151 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : (DSR 9.74) 250x10 mm (DSR 9.74.1) 152 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : (DSR 9.74) 200x10 mm (DSR 9.74.2) 153 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : (DSR 9.74) 150x10 mm (DSR 9.74.3) 154 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : (DSR 9.74) 100x10 mm (DSR 9.74.4) 155 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (DSR )(DSR 9.76) 156 Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete. (DSR )(DSR 9.77) 157 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. (DSR )(DSR 9.83) 158 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. (DSR )(DSR 9.84) 159 Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete : (DSR 9.87) 150 mm (DSR 9.87.1) 160 Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete : (DSR 9.87) 115 mm (DSR 9.87.2) 161 Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete : (DSR 9.87) 90 mm (DSR 9.87.3) 162 Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (DSR )(DSR 9.88) 163 Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. (DSR )(DSR 9.89) 164 Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. (DSR 9.9) Size 40 mm (DSR 9.90.1) 165 Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. (DSR 9.9) Size 50 mm (DSR 9.90.2) 166 Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. (DSR 9.9) Size 65 mm (DSR 9.90.3) 167 Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. (DSR 9.9) Size 75 mm (DSR 9.90.4) 168 Providing and fixing chromium plated brass 50 mm cupboard or wardrobe knobs with nuts complete. (DSR )(DSR 9.91) 169 Providing and fixing chromium plated brass handles with necessary screws etc. complete: (DSR 9.92) 125 mm (DSR 9.92.1) 170 Providing and fixing chromium plated brass handles with necessary screws etc. complete: (DSR 9.92) 100 mm (DSR 9.92.2) 171 Providing and fixing chromium plated brass handles with necessary screws etc. complete: (DSR 9.92) 75 mm (DSR 9.92.3) 172 Providing and fixing chromium plated brass casement window fastener with necessary screws etc. complete. (DSR )(DSR 9.93) 173 Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: (DSR 9.95) 125x63x4 mm (DSR 9.95.2) 174 Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: (DSR 9.95) 100x63x3.2 mm (DSR 9.95.5) 175 Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: (DSR 9.95) 75x63x3.2 mm (DSR 9.95.7) 176 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : (DSR 9.96) 300x16 mm (DSR 9.96.1) 177 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : (DSR 9.96) 250x16 mm (DSR 9.96.2) 178 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.97) 300x10 mm (DSR 9.97.1) 179 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.97) 250x10 mm (DSR 9.97.2) 180 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.97) 200x10 mm (DSR 9.97.3) 181 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.97) 150x10 mm (DSR 9.97.4) 182 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.97) 100x10 mm (DSR 9.97.5) 183 Providing and fixing aluminium pull bolt lock, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws bolts, nut and washers etc. complete. (DSR )(DSR 9.98) 184 Providing and fixing 50 cm long aluminium kicking plate of size 100x3.15 mm, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete. (DSR )(DSR 9.99) 185 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.1) 125 mm (DSR 9.100.1) 186 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.1) 100 mm (DSR 9.100.2) 187 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.1) 75 mm (DSR 9.100.3) 188 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. (DSR 9.101) Single rubber stopper (DSR 9.101.1) 189 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. (DSR 9.101) Twin rubber stopper (DSR 9.101.2) 190 Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete. (DSR )(DSR 9.103) 191 Providing and fixing aluminium tee channels (heavy duty) with rollers & stop end in pelmets as curtain rod. (DSR )(DSR 9.104) 192 Providing and fixing Bamboo jaffery/ fencing consisting of superior quality 25mm dia (Average) half cut bamboo placed vertically and fixed together with three numbers horizontal running members of hollock wood in scantling of section 50X25 mm, fixed with nails and G.I wire on existing support complete as per direction of Engineer-in-charge. (DSR )(DSR 9.110) 193 Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. (DSR 9.114) Triple strip vertical type (DSR 9.114.1) 194 Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. (DSR 9.114) Double strip (horizontal type) (DSR 9.114.2) 195 Providing and fixing powder coated telescopic drawer channels 300 mm long with necessary screws etc. complete as per directions of Engineer- in-charge. (DSR )(DSR 9.115) 196 Providing and fixing sliding arrangement in racks/ cupboards/cabinets shutter by with stainless steel rollers to run inside C or E aluminium channel section (The payment of C or E channel shall be made separately) (DSR )(DSR 9.116) 197 Providing and fixing 12 mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. (DSR 9.126) Marine plywood conforming to IS: 710 (DSR 9.126.1) 198 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. (DSR 9.127) 1.5 mm thick (DSR 9.127.1) 199 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. (DSR 9.127) 1.0 mm thick (DSR 9.127.2) 200 Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the Engineer-in-Charge (DSR )(DSR 9.129) 201 Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws :30 mm thick shutters (DSR 9.134.2) With ISI marked stainless steel butt hinges of required size 9.134.2.2 Second class teak wood (DSR 9.134.2.2.1 ) 202 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. (DSR 9.135) With 2nd class teak wood beading 62X19 mm (DSR 9.135.1) 203 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (DSR 9.165) 125 mm (DSR 9.165.1) 204 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (DSR 9.165) 100mm (DSR 9.165.2) 205 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (DSR 9.165) 75 mm (DSR 9.165.3) 206 Providing and fixing 18mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. in partitions, boxes, shelves, racks and cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in-charge (Note: Fittings to be paid separately). (DSR 9.166) 18 mm thick (DSR 9.166.1) 207 Providing and fixing 6mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. on the backing of racks, drawer, cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in-charge. (DSR )(DSR 9.167) 208 Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge.(Payment of providing and fixing auto closing hinges shall be paid separately)(DSR )(DSR 9.168) 209 Providing and fixing 19mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand boxes,shelves,racks,almirah,cupboard and drawer etc. including necessary nails,screws etc.complete as per direction of Engineer-in-charge.(DSR )(DSR 9.169) 210 Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. (DSR 9.17) 200 mm (DSR 9.170.1) 211 Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge. (DSR )(DSR 9.171) 212 Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc. complete as per directions of Engineer- in-charge. (DSR )(DSR 9.172) 213 Providing and fixing ready made 304 grade stainless steel Modular kitchen basket and accessories such as right angle basket (Plain Cup & Saucer, plant, Partition, Bottle rack, Thali, Cutlery) kitchen utensilbasket, Dinner set basket, kitchen grain basket, Multipurpose basket as per site requirement including finishing (wherever required) and fittings. The same shall be fixed with necessary stainless steel nuts & bolts, Stainless Steel screws & telescopic channel etc. as per direction of Engineer-in-charge. (For payment purpose only weight of Stainless steel basket shall be considered excluding weight of all fixing accessories such as nuts, bolts, fasteners telescopic basket channels etc. Payment of providing and fixing telescopic channel shall be paid separately) (DSR )(DSR 9.173) 214 Providing and fixing 2mm thick 16 to 19mm wide PVC edge binding tape of approved quality for cupboard/wardrobe shutters including necessary synthetic resin hot pressed to edges on binding machine etc. complete as per directions of Engineer- in-charge. (DSR )(DSR 9.174) 215 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR )(DSR 10.1) 216 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR )(DSR 10.2) 217 Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost. (DSR 10.1) Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) (DSR 10.10.1) 218 Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost. (DSR 10.1) Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) (DSR 10.10.2) 219 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. (DSR 10.15) Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) (DSR 10.15.1) 220 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. (DSR 10.15) Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) (DSR 10.15.2) 221 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. (DSR 10.16) Electric resistance or induction butt welded tubes (DSR 10.16.3) 222 Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. (DSR )(DSR 10.17) 223 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. (DSR )(DSR 10.18) 224 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (DSR 10.25) In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete (DSR 10.25.1) 225 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (DSR 10.25) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (DSR 10.25.2) 226 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. (DSR 10.26) M.S. tube (DSR 10.26.1) 227 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. (DSR 10.26) E.R.W. tubes (DSR 10.26.2) 228 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). (DSR )(DSR 10.28) 229 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. (DSR 10.29) Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides (DSR 10.29.2) 230 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : (DSR 10.3) 4.0 mm thick glass panes (DSR 10.30.1) 231 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener,including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. (DSR )(DSR 10.31) 232 Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: (DSR 11.1) 1:4 (1 cement : 4 coarse sand) (DSR 11.1.1) 233 Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: (DSR 11.1) 1:6 (1cement : 6 coarse sand) (DSR 11.1.2) 234 Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. (DSR )(DSR 11.2) 235 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (DSR 11.3) 40 mm thick with 20 mm nominal size stone aggregate (DSR 11.3.1) 236 Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. (DSR 11.6) 18 mm thick (DSR 11.6.1) 237 Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete. (DSR )(DSR 11.7) 238 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. (DSR ) 40 mm wide and 4 mm thick (DSR 11.13.1) 239 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). (DSR 11.2) Dark shade pigment using ordinary cement (DSR 11.20.3) 240 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). (DSR 11.2) Ordinary cement without any pigment (DSR 11.20.4) 241 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. (DSR 11.21) In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) 11.21.1 Acid and alkali resistant tile (DSR 11.21.1.1) 242 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. (DSR 11.21) In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) 11.21.2 Acid and alkali resistant tile (DSR 11.21.2.1) 243 Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : (DSR 11.23) Udaipur green marble (DSR 11.23.5) 244 Extra for pre finished nosing to treads of steps of marble stone. (DSR )(DSR 11.24) 245 Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 metre. (DSR )(DSR 11.25) 246 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : (DSR 11.26) 25 mm thick (DSR 11.26.1) 247 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (DSR )(DSR 11.27) 248 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints finished flush. (DSR 11.28) Red sand stone (DSR 11.28.1) 249 Extra for Kota stone/ sand stone in treads of steps and risers using single length above normal size up to 2.00 metre. (DSR )(DSR 11.32) 250 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (DSR )(DSR 11.37) 251 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (DSR )(DSR 11.37A) 252 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. (DSR )(DSR 11.38) 253 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. (DSR 11.41) Size of Tile 600x600 mm (DSR 11.41.2) 254 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. (DSR 11.41A) Double charge vitrified tile polished finish of size 11.41A.1 Size of Tile 600 x 600 mm (DSR 11.41A.1.1) 255 Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick jamuna sand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge. (DSR )(DSR 11.45) 256 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. (DSR 11.48) Size of Tile 600x600 mm (DSR 11.48.2) 257 Providing and laying full body vitrified tile in floor of minimum thickness 15 mm with water absorption less than 0.06% and conforming to IS:15622, of approved make, brand and manufacturer, laid on 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.30 kg / sqm including grouting thejoints with white cement and matching pigments etc. The slab must be cut with the zero chipping diamond cutter only.Laying of slab will be done with the help of notch trowel, wedge, clips of required thickness, vacuum cups for lifting, leveling system and rubber mallet for placing the slab gently and easily. Size of tile 800x2400mm of all colours and shades.(DSR )(DSR 11.49A) 258 Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles. (DSR )(DSR 11.50) 259 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (DSR 12.42) Coupler 12.42.1 75 mm (DSR 12.42.1.1) 260 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (DSR 12.42) Coupler 12.42.1 110 mm (DSR 12.42.1.2) 261 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : (DSR 12.45) 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) (DSR 12.45.1) 262 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated J or L hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. (DSR 12.47) 2 mm thick flat (DSR 12.47.2) 263 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spacedjoints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. (DSR 12.52) 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. (DSR 12.52.4) 264 Providing and fixing tiled false ceiling of specifiedmaterials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. (DSR 12.58) 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing. (DSR 12.58.1) 265 Providing & fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes,finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufactures specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specificaton and direction of the Engineer in charge but excluding the cost of painting with: (DSR 12.59) 8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process. (DSR 12.59.1) 266 Providing & fixing at all heights, levels and locations Mill finish Aluminium alloy roofing sheets of alloyIS designation31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). (DSR 12.64) 0.56 mm, Aluminium troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm. (DSR 12.64.1) 267 Providing and fixing of Pre-coated colour or mill finishAluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : (DSR 12.66) Precoated/mill finish aluminium Ridges plain (500- 600mm) (DSR 12.66.1) 268 Providing and fixing of Pre-coated colour or mill finishAluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : (DSR 12.66) Precoated/mill finish aluminium Crimp curve (DSR 12.66.5) 269 Providing and fixing of Pre-coated colour or mill finishAluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : (DSR 12.66) Precoated/mill finish aluminium Gutter (600 mm over all girth) (DSR 12.66.6) 270 12 mm cement plaster of mix :CEMENT PLASTER (IN COARSE SAND) (DSR 13.4) 1:4 (1 cement: 4 coarse sand) (DSR 13.4.1) 271 12 mm cement plaster of mix :CEMENT PLASTER (IN COARSE SAND) (DSR 13.4) 1:6 (1 cement: 6 coarse sand) (DSR 13.4.2) 272 12 mm cement plaster finished with a floating coat of neat cement of mix : (DSR 13.7) 1:4 (1 cement: 4 fine sand) (DSR 13.7.2) 273 6 mm cement plaster of mix : (DSR 13.16) 1:3 (1 cement : 3 fine sand) (DSR 13.16.1) 274 Neat cement punning. (DSR )(DSR 13.18) 275 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. (DSR )(DSR 13.21) 276 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : (DSR 13.41) New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre (DSR 13.41.1) 277 Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.46) New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (DSR 13.46.1) 278 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: (DSR 13.47) New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (DSR 13.47.1) 279 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : (DSR 13.48) Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm (DSR 13.48.1) 280 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : (DSR 13.48) Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture (DSR 13.48.2) 281 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : (DSR 13.48) Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture (DSR 13.48.3) 282 Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shadewith silicon additives. (DSR 13.48A) New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. (DSR 13.48A.1) 283 Coal tarring two coats on new work using 0.16 Litre and 0.12 litre coal tar per sqm in the first coat and second coat respectively. (DSR )(DSR 13.59) 284 Lettering with black Japan paint of approved brand and manufacture (DSR )(DSR 13.71) 285 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR )(DSR 13.80) 286 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturerincluding applying additional coats wherever required to achieve even shade and colour(DSR 13.81) Old work (one or more coats) (DSR 13.81.1) 287 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. (DSR 13.82) One coat (DSR 13.82.1) 288 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. (DSR 13.82) Two coats (DSR 13.82.2) 289 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. (DSR 13.83) One coat (DSR 13.83.1) 290 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. (DSR 13.83) Two coats (DSR 13.83.2) 291 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. (DSR 13.85) With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre (DSR 13.85.1) 292 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. (DSR 13.85) With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre (DSR 13.85.3) 293 White washing with lime to give an even shade : (DSR 13.87) Old work (two or more coats) (DSR 13.87.1) 294 White washing with lime to give an even shade : (DSR 13.87) Old work (one or more coats) (DSR 13.87.2) 295 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete (DSR )(DSR 13.88) 296 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. (DSR )(DSR 13.91) 297 Painting with oil type wood preservative of approved brand and manufacture: (DSR 13.97) Old work (one or more coats) (DSR 13.97.1) 298 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : (DSR 13.99) One or more coats on old work (DSR 13.99.1) 299 Re-lettering with black Japan paint of approved brand and manufacture. (DSR )(DSR 13.105) 300 Painting (one or more coats) with black Japan paint of approved brand and manufacture to give an even shade. (DSR )(DSR 13.106) 301 Finishing walls with textured exterior paint of required shade : (DSR 13.11) Old work (One or more coats) applied @ 1.82 ltr/10 sqm. (DSR 13.110.2) 302 Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.111) Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface (DSR 13.111.1) 303 Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.111) Old work (One or more coat applied @ 0.90 ltr/10 sqm). (DSR 13.111.2) 304 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade (DSR 13.112) Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface (DSR 13.112.1) 305 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade (DSR 13.112) Old work (one or more coats applied @ 0.83 ltr/10 sqm). (DSR 13.112.2) 306 Varnishing with varnish of approved brand and manufacture: (DSR 13.113) One or more coats with copal varnish (DSR 13.113.1) 307 Melamine polishing on wood work (one or more coat). (DSR )(DSR 13.114) 308 Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:1.The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) (DSR )(DSR 13.116) 309 Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. (DSR 14.2) Door chowkhats (DSR 14.2.1) 310 Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. (DSR 14.2) Window chowkhats (DSR 14.2.2) 311 Fixing chowkhat in existing opening in brick/ RCC wall with dash fasteners/Chemical fasteners of appropriate size (3 nos on each vertical member of door chowkhat and 2 nos on each vertical member of window chowkhats), including Cost of dash fasteners/ chemical fastener. (DSR )(DSR 14.3) 312 Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge. (DSR 14.4) For door/ window/ clerestory window (DSR 14.4.1) 313 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: (DSR 14.5) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) (DSR 14.5.1) 314 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: (DSR 14.5) Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) (DSR 14.5.2) 315 Renewing glass panes and refixing existing wooden fillets: (DSR 14.7) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) (DSR 14.7.1) 316 Renewing glass panes and refixing existing wooden fillets: (DSR 14.7) Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) (DSR 14.7.2) 317 Supplying and fixing new wooden fillets wherever necessary: (DSR 14.8) Hollock wood fillets (DSR 14.8.2) 318 Renewal of old putty of glass panes (length) (DSR )(DSR 14.9) 319 Refixing old glass panes with putty and nails (DSR )(DSR 14.10) 320 Fixing old glass panes with wooden fillets (excluding cost of fillets) (DSR )(DSR 14.11) 321 Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. (DSR )(DSR 14.12) 322 Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. (DSR )(DSR 14.17) 323 Renewing Wrought iron or M.S. Wheel or roller of steel door or gate and fitting and fixing the same with necessary clamps, nuts and bolts/welding and erection etc. complete. (DSR 14.22) Wheel 50 mm dia and below (DSR 14.22.1) 324 Renewing Wrought iron or M.S. Wheel or roller of steel door or gate and fitting and fixing the same with necessary clamps, nuts and bolts/welding and erection etc. complete. (DSR 14.22) Wheel above 50 mm dia (DSR 14.22.2) 325 Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. (DSR )(DSR 14.23) 326 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 14.26) Panelled or panelled & glazed shutters : 14.26.1 Superior class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. (DSR 14.26.1.1) 327 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 14.26) Panelled or panelled & glazed shutters : 14.26.1 Ist class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. (DSR 14.26.1.2) 328 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 14.26) Glazed shutters : 14.26.2 Superior class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. (DSR 14.26.2.1) 329 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 14.26) Glazed shutters : 14.26.2 Ist class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. (DSR 14.26.2.2) 330 Providing and fixing M.S. round or square bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows. (DSR )(DSR 14.29) 331 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 125x70x4 mm (ordinary type) (DSR 14.40.1) 332 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 100x70x4 mm (ordinary type) (DSR 14.40.2) 333 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 75x65x4 mm (heavy type) (DSR 14.40.3) 334 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 75x40x2.5 mm (ordinary type) (DSR 14.40.4) 335 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 50x40x2.5 mm (ordinary type) (DSR 14.40.5) 336 Providing and fixing 85x42 mm chromium plated brass pull bolt lock with necessary chromium plated brass screws, nuts, bolts and washers etc. complete. (DSR )(DSR 14.41) 337 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) (DSR )(DSR 14.75A) 338 Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge. (DSR )(DSR 14.76) 339 Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm(DSR )(DSR 14.77) 340 Cleaning of under ground sump, Over Head R.C.C. Tank ( independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consistfollowing operations:- (i)Tank shall be emptied of water by pumping & bottom shall be cleaned of silt and otherdeposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine.(iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge. (DSR )(DSR 14.78) 341 Disconnecting damaged overhead/terrace PVC water storage tankof any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge. (DSR )(DSR 14.79) 342 Providing & fixing White vitreous china water closet squatting pan (Indian type) along withS or P trap including dismantling of old WC seat and S or P trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. (DSR 14.8) Orissa pattern W.C Pan of size 580x440 mm (DSR 14.80.2) 343 Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge. (DSR )(DSR 14.81) 344 DismantlingW.C.Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge. (DSR )(DSR 14.82) 345 Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. (DSR )(DSR 14.83) 346 Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge. (a) Internal Work- Exposed on wall (DSR )(DSR 14.84) 347 Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. (DSR )(DSR 14.85) 348 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. (DSR 15.2) Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) (DSR 15.2.2) 349 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. (DSR )(DSR 15.3) 350 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (DSR 15.7) In cement mortar (DSR 15.7.4) 351 Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): (DSR 15.8) From brick work in cement mortar (DSR 15.8.3) 352 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : (DSR 15.12) Of area 3 sq. metres and below (DSR 15.12.1) 353 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : (DSR 15.12) Of area beyond 3 sq. metres (DSR 15.12.2) 354 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : (DSR 15.13) Of area 3 sq. metres and below (DSR 15.13.1) 355 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : (DSR 15.13) Of area beyond 3 sq. metres (DSR 15.13.2) 356 Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: (DSR 15.17) R.S. Joists (DSR 15.17.1) 357 Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: (DSR 15.17) Channels, angles, tees and flats (DSR 15.17.2) 358 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. (DSR )(DSR 15.18) 359 Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. (DSR )(DSR 15.19) 360 Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead : (DSR )(DSR 15.24) 361 Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: (DSR 15.28) G.S. Sheet (DSR 15.28.1) 362 Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: (DSR 15.28) Asbestos Cement sheet (DSR 15.28.2) 363 Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead. (DSR )(DSR 15.36) 364 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : (DSR 15.44) 15 mm to 40 mm nominal bore (DSR 15.44.1) 365 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : (DSR 15.44) Above 40 mm nominal bore (DSR 15.44.2) 366 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: (DSR 15.45) Up to 150 mm diameter (DSR 15.45.1) 367 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. (DSR )(DSR 15.48) 368 Taking out C.I. cover with frame from R.C.C. top slab of inspection chambers of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. (DSR )(DSR 15.49) 369 Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. (DSR )(DSR 15.52) 370 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres (DSR 15.53) Up to 150 mm diameter (DSR 15.53.1) 371 Dismantling of spindle fire hydrant including stacking of useful materials within 50 metres lead. (DSR )(DSR 15.54) 372 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (DSR )(DSR 15.56) 373 Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. (DSR )(DSR 15.57) 374 Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars. (DSR )(DSR 15.58) 375 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (DSR )(DSR 15.60) 376 Brick edging in full brick width and half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres. (DSR 16.7) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 16.7.1) 377 Brick edging laid lengthwise with half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres : (DSR 16.8) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 16.8.1) 378 Supplying at site : (DSR 16.15) R.C.C. Standards post/ struts/rails/ pales of mix 1:1.5:3 (1 cement : 1.5 coarsesand : 3 graded stone aggregate 12.5 mm nominal size) with wooden plugs or 6mm bar nibs wherever required as per direction of Engineer-in- charge (cost of earth works in excavation, concrete works in foundation to be paid separately). (DSR 16.15.1) 379 Supplying at site : (DSR 16.15) Welded steel wire fabric of required width having rectangular mesh painted with two or more coats of enamel paint of approved shade over a coat of primer (Priming & Painting to be paid for separately). (DSR 16.15.2) 380 Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately) :- Payment to be made per metre cost of total length of barbed wire used. (DSR 16.17) With G.I. barbed wire (DSR 16.17.1) 381 Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. (DSR 16.18) With G.I. barbed wire (DSR 16.18.1) 382 Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. (DSR )(DSR 16.19) 383 Providing and applying tack coat using bitumen emulsion conforming to IS:8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom. (DSR 16.31) With medium setting bitumen emulsion 16.31.2 On bituminous surface @ 0.25kg/sqm (DSR 16.31.2.2) 384 2.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum of stone chippings of 13.2 mm and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively, including a tack coat with hot straight run bitumen, including consolidation with road roller of 6 to 9 tonne capacity etc. complete (tack coat to be paid for separately). (DSR 16.33) With paving Asphalt grade VG - 10 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt (DSR 16.33.1) 385 Providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete. (DSR )(DSR 16.40) 386 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete. (DSR )(DSR 16.42) 387 Extra for providing and mixing hardening compound of approved quality as per manufacturers specification in cement concrete. (DSR )(DSR 16.44) 388 Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) (DSR )(DSR 16.45) 389 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron Y shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) (DSR )(DSR 16.53) 390 Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineer-in-charge. (DSR )(DSR 16.64) 391 Providing and fixing at or near ground level factory made RCC pavement slab of M-30 grade of size 450x450x50 mm, including reinforcement with 6 mm dia M.S. bars 4 nos on each side, including setting in position in footpath to the required level and line over a bed of 20 mm average thick cement mortar 1:5 (1 cement : 5 coarse sand), having joint thickness not more than 5mm except on curve, including filling of joints with same cement mortar and making grooves etc. complete as per direction of Engineer-in-charge. (DSR )(DSR 16.67) 392 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. (DSR )(DSR 16.68) 393 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). (DSR )(DSR 16.69) 394 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. (DSR 16.7) Made of G.I. wire of dia 4 mm (DSR 16.70.1) 395 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). (DSR )(DSR 16.75) 396 Deduct for using of M-20 grade concrete instead of M-25 grade concrete in C.C. pavement. (DSR )(DSR 16.76) 397 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. (DSR 16.78) With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 (DSR 16.78.2) 398 Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. (DSR )(DSR 16.83) 399 Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost). (DSR )(DSR 16.84) 400 Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. (DSR )(DSR 16.89) 401 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (DSR 16.91) 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. (DSR 16.91.1) 402 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (DSR 16.91) 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. (DSR 16.91.2) 403 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: (DSR 17.1) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (DSR 17.1.1) 404 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : (DSR 17.2) W.C. pan with ISI marked white solid plastic seat and lid (DSR 17.2.1) 405 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : (DSR 17.3) W.C. pan with ISI marked white solid plastic seat and lid (DSR 17.3.1) 406 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (DSR 17.7) White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps (DSR 17.7.3) 407 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (DSR 17.7) White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap (DSR 17.7.4) 408 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (DSR 17.7) White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers ISI Marked (DSR 17.7.9) 409 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (DSR 17.7) Stainless Steel AISI-304(18/8) Wash basin 530x345 mm with single 15 mm C.P. brass pillar tap (DSR 17.7.11) 410 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a)White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer (DSR )(DSR 17.7A) 411 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required: (DSR 17.9) White glazed fire clay kitchen sink of size 600x450x 250 mm (DSR 17.9.1) 412 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (DSR 17.1) Kitchen sink with drain board510x1040 mm bowl depth 200 mm (DSR 17.10.1.3) 413 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (DSR 17.1) Kitchen sink without drain board 17.10.2 610x510 mm bowl depth 200 mm (DSR 17.10.2.1) 414 Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan. (DSR )(DSR 17.15) 415 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. (DSR )(DSR 17.16A) 416 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. (DSR 17.18) 10 litre capacity - White (DSR 17.18.1) 417 Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete : (DSR 17.2) White solid plastic seat with lid (DSR 17.20.1) 418 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. (DSR )(DSR 17.22A) 419 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.(a) 15 mm nominal dia (DSR )(DSR 17.22B) 420 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. (DSR )(DSR 17.23) 421 Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. (DSR )(DSR 17.24) 422 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : (DSR 17.25) Flat back wash basin of size 630x450 mm (DSR 17.25.1) 423 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : (DSR 17.25) Flat back wash basin of size 550x400 mm (DSR 17.25.2) 424 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : (DSR 17.25) Flat back wash basin of size 450x300 mm (DSR 17.25.5) 425 Providing and fixing kitchen sink including making all connections excluding cost of fittings. (DSR 17.26) White glazed fire clay sink of size 600x450x250 mm (DSR 17.26.1) 426 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (DSR 17.28) Semi rigid pipe 17.28.1 32 mm dia (DSR 17.28.1.1) 427 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (DSR 17.28) Flexible pipe 17.28.2 32 mm dia (DSR 17.28.2.1) 428 Providing and fixing 100 mm sand cast Iron grating for gully trap. (DSR )(DSR 17.29) 429 Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design. (DSR )(DSR 17.30) 430 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (DSR )(DSR 17.31) 431 Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. (DSR )(DSR 17.33) 432 Providing and fixing toilet paper holder : (DSR 17.34) C.P. brass (DSR 17.34.1) 433 Providing and fixing toilet paper holder : (DSR 17.34) Vitreous china (DSR 17.34.2) 434 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. (DSR 17.69) Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms (DSR 17.69.1) 435 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. (DSR 17.69) Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms (DSR 17.69.2) 436 Providing and fixing PTMT Bottle Trap for Wash basin and sink. (DSR 17.7) Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms (DSR 17.70.1) 437 Providing and fixing PTMT Bottle Trap for Wash basin and sink. (DSR 17.7) Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms (DSR 17.70.2) 438 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. (DSR )(DSR 17.71) 439 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. (DSR )(DSR 17.72) 440 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. (DSR 17.73) 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms (DSR 17.73.1) 441 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. (DSR 17.73) 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. (DSR 17.73.2) 442 Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms. (DSR )(DSR 17.74) 443 Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2 BSP thread and shapes, weighing not less than 60 gms. (DSR )(DSR 17.75) 444 Providing and fixing PTMT urinal cock of approved quality and colour. (DSR 17.76) 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with BSP female threads weighing not less than 48 gms (DSR 17.76.1) 445 Providing and fixing M.S. holder bat clamp of approved design to sand cast iron/ cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5 mm flat of specified shape, projecting 75 mm outside the wall surface and fixed on wall with 4nos, 6mm dia expansion hold fasteners, including drilling necessary holes in brick wall/ CC/ RCC surface and the cost of bolts etc. The pipes shall be fixed to the already fixed brackets with the help of 30 mm x1.6 mm galvanised M.S. flats of specified shape and of total length 420 mm and shall be fixed with M.S. nuts, bolts, & washers of size 25x6 mm, one bolts on each side of the pipe. (DSR 17.77) Total bracket length 580 mm of approved shape and design (for single 100 mm dia pipe) (DSR 17.77.1) 446 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. (DSR )(DSR 17.78) 447 Providing & fixing white vitreous china water less urinal of size 600 x 330 x 315 mm having antibacterial /germs free ceramic surface, fixed with cartridge having debris catcher and hygiene seal. (DSR )(DSR 17.79) 448 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (DSR )(DSR 17.80) 449 Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. (DSR )(DSR 17.81) 450 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.(Concealed work, including cutting chases and making good the walls etc.) (DSR 18.8) 20 mm nominal dia Pipes (DSR 18.8.2) 451 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.(Concealed work, including cutting chases and making good the walls etc.) (DSR 18.8) 25 mm nominal dia Pipes (DSR 18.8.3) 452 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 15 mm nominal dia Pipes (DSR 18.9.1) 453 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 20 mm nominal dia Pipes (DSR 18.9.2) 454 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 25 mm nominal dia Pipes (DSR 18.9.3) 455 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 32 mm nominal dia Pipes (DSR 18.9.4) 456 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 40 mm nominal dia Pipes (DSR 18.9.5) 457 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 50 mm nominal dia Pipes (DSR 18.9.6) 458 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 80 mm nominal dia Pipes (DSR 18.9.8) 459 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work (DSR 18.12) 80 mm dia nominal bore (DSR 18.12.8) 460 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : (DSR 18.13) 25 to 40 mm nominal bore (DSR 18.13.1) 461 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : (DSR 18.13) 50 to 80 mm nominal bore (DSR 18.13.2) 462 Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately). (DSR )(DSR 18.14) 463 Providing and fixing brass bib cock of approved quality : (DSR 18.15) 15 mm nominal bore (DSR 18.15.1) 464 Providing and fixing brass bib cock of approved quality : (DSR 18.15) 20 mm nominal bore (DSR 18.15.2) 465 Providing and fixing brass stop cock of approved quality : (DSR 18.16) 15 mm nominal bore (DSR 18.16.1) 466 Providing and fixing brass stop cock of approved quality : (DSR 18.16) 20 mm nominal bore (DSR 18.16.2) 467 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 25 mm nominal bore (DSR 18.17.1) 468 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 20 mm nominal bore (DSR 18.17.1A) 469 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 32 mm nominal bore. (DSR 18.17.2) 470 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 40 mm nominal bore (DSR 18.17.3) 471 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 80 mm nominal bore (DSR 18.17.6) 472 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 25 mm nominal bore 18.19.1 Horizontal (DSR 18.19.1.1) 473 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 25 mm nominal bore 18.19.1 Vertical (DSR 18.19.1.2) 474 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 32 mm nominal bore 18.19.2 Horizontal (DSR 18.19.2.1) 475 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 32 mm nominal bore 18.19.2 Vertical (DSR 18.19.2.2) 476 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 40 mm nominal bore 18.19.3 Horizontal (DSR 18.19.3.1) 477 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 40 mm nominal bore 18.19.3 Vertical (DSR 18.19.3.2) 478 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 80 mm nominal bore 18.19.6 Vertical (DSR 18.19.6.2) 479 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 30 cm length 18.21.1 15 mm nominal bore (DSR 18.21.1.1) 480 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 30 cm length 18.21.1 20 mm nominal bore (DSR 18.21.1.2) 481 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 45 cm length 18.21.2 15 mm nominal bore (DSR 18.21.2.1) 482 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 45 cm length 18.21.2 20 mm nominal bore (DSR 18.21.2.2) 483 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : (DSR 18.22) 100 mm diameter (DSR 18.22.1) 484 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : (DSR 18.22) 150 mm diameter (DSR 18.22.2) 485 Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536 : (DSR 18.27) 100 mm dia pipe (DSR 18.27.1) 486 Providing lead caulked joints to spun iron or C.I. pipes and specials, including testing of joints but excluding the cost of pig lead : (DSR 18.28) 100 mm diameter pipe (DSR 18.28.1) 487 Providing flanged joints to double flanged C.I./ D.I. pipes and specials, including testing of joints : (DSR 18.3) 80 mm diameter pipe (DSR 18.30.1) 488 Providing flanged joints to double flanged C.I./ D.I. pipes and specials, including testing of joints : (DSR 18.3) 100 mm diameter pipe (DSR 18.30.2) 489 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : (DSR 18.31) 100 mm diameter 18.31.1 Class I (DSR 18.31.1.1) 490 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : (DSR 18.31) 100 mm diameter 18.31.1 Class II (DSR 18.31.1.2) 491 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (DSR )(DSR 18.48) 492 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (DSR 18.62) 20 mm nominal bore, 120 mm long, weighing not less than 198 gms (DSR 18.62.2) 493 Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms (DSR )(DSR 18.63) 494 Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms (DSR )(DSR 18.64) 495 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. (DSR )(DSR 18.65) 496 Providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. (DSR 18.84) 15 mm nominal bore (DSR 18.84.1) 497 Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps : (DSR 19.5) 100 mm diameter (DSR 19.5.1) 498 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : (DSR 19.6) 150 mm dia. R.C.C. pipe (DSR 19.6.2) 499 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : (DSR 19.6) 300 mm dia. R.C.C. pipe (DSR 19.6.4) 500 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. (DSR 19.32) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.32.1) 501 Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. (DSR )(DSR 19.33) 502 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For fixed portion 21.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) (DSR 21.1.1.1) 503 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For fixed portion 21.1.1 Powder coated aluminium (minimum thickness of powder coating 50 micron) (DSR 21.1.1.2) 504 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For fixed portion 21.1.1 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (DSR 21.1.1.3) 505 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) (DSR 21.1.2.1) 506 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) (DSR 21.1.2.2) 507 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (DSR 21.1.2.3) 508 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3) With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) (DSR 21.3.1) 509 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3) With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) (DSR 21.3.2) 510 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3) With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) (DSR 21.3.3) 511 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. (DSR 21.4) With stainless steel cover plate minimum 1.25 mm thickness (DSR 21.4.1) 512 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. (DSR 21.4) With brass cover plate minimum 1.25 mm thickness (DSR 21.4.2) 513 Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). (DSR )(DSR 21.5) 514 Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer-in-charge. (DSR )(DSR 21.6) 515 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. (DSR 21.8) Upto 5mm depth and 5 mm width (DSR 21.8.1) 516 Extra for applying additional anodic coating AC 25 instead of AC 15 to aluminium extruded sections. (DSR 21.9) For fixed portion (DSR 21.9.1) 517 Extra for applying additional anodic coating AC 25 instead of AC 15 to aluminium extruded sections. (DSR 21.9) For shutters of doors, windows & ventilators (DSR 21.9.2) 518 Providing and fixing anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868. Minimum anodic coating of grade AC 15) sub frame work for windows and ventilators with extruded built up standard tubular sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia and size (Dash fastener to be paid for separately). (DSR )(DSR 21.14) 519 Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). (DSR )(DSR 21.17) 520 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). (DSR )(DSR 21.18) 521 Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11601 (DSR 21.19) Upto 5 mm depth and 5 mm width (DSR 21.19.1) 522 Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11602 (DSR 21.19) Upto 10 mm depth and 10 mm width (DSR 21.19.2) 523 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.(The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) (DSR )(DSR 22.5) 524 Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck ,using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturers specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. (DSR )(DSR 22.22) 525 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. (DSR 23.1) All types of soil 23.1.1 300 mm dia (DSR 23.1.1.1) 526 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. (DSR 23.2) All types of soil 23.2.1 350 mm dia (DSR 23.2.1.2) 527 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. (DSR 23.3) 150 mm nominal size dia (DSR 23.3.2) 528 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. (DSR 23.4) 150 mm nominal size dia (DSR 23.4.2) 529 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (DSR )(DSR 23.5) 530 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (DSR )(DSR 23.6) 531 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. (DSR )(DSR 23.7) 532 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. (DSR )(DSR 23.8) 533 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. (DSR )(DSR 23.12) 534 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: (DSR 23.13) 150 mm dia (DSR 23.13.2) 535 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. (DSR 23.14) 150 mm clamp (DSR 23.14.2) 536 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). (DSR 23.15) 150 mm dia (DSR 23.15.2) 537 Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment. (DSR )(DSR 25.1) 538 Providing and fixing factory madeKitchen Cabinet Shutter/Partition 20 mm nominal thickness of approved shade, quality and make, made from rigid foam sheets (Single extruded) having density 600 Kg/cum and laminated on both side by laminate Sheet/PVC foil lamination. The exposed edges shall be sealed with PVC edge beading of same shade and colour. The shutter shall be fire retardenthaving necessary screw holding capacity.Shutter shall be fixed to frame usingapproved hinges with necessary stainless steel screws, all complete as per direction of Engineer-in-charge. (DSR )(DSR 26.10) 539 Providing and fixing concealed hinge of approved quality for 19-20mm thick door with stainless steel screws complete : (DSR )(DSR 26.11) 540 Wiring for light point/ fan point/ exhaust fan point/ call bell point with1.5 sq mm frls pvc insulated copper conductor single core cable in surface /recessed medium class pvc conduit , with modular switch ,modular plate, suitable GI box and earething the pint with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (DSR E&M 1.10)Group A (DSR E&M 1.10.1) 541 Wiring for light/power plug with 2x4 sq. mm FRLS PVC insulatted copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (DSR E&M 1.12) 542 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (DSR E&M 1.14) 2x2.5sq. Mm + 1x2.5 sq. mm eartrh wire (DSR E&M 1.14.2) 543 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (DSR E&M 1.14) 2x4sq. Mm + 1x4 sq. mm eartrh wire (DSR E&M 1.14.3) 544 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (DSR E&M 1.21) 25mm (DSR E&M 1.21.2) 545 Supplying and fixing 6way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240V, on Surface/recess,complete with tinned copper bus bar, heutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But with MCB/RCCB/Isolator) (DSR E&M 2022 2.3.1) 546 Supplying and fixing 5 amps to 32 amps rating,Single pole, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR E&M 2022 2.10.1) 547 Supplying and fixing 63 amps, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(DSR E&M 2022 2.12.2) 548 Supplying and fixing 63 A, four pole, 415V, isolator in the existing MCB DB Complete with connections, testing and commissioning etc. as required. (DSR E&M 2022 2.13.2) 549 Earthing with G.I earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (DSR E&M 2022 5.2) 550 Smoke Detector with built in LED, mounting base complete with all connection etc. (DSR E&M 2022 4102) 551 Manual call boxes of MS Type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. (DSR E&M 2022 4103) 552 Manual call boxes of ABS Type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. (DSR E&M 2022 4104) 553 Response indicator on surface/recessed MS Box having two LEDs metallic covers complete with all connections etc.(DSR E&M 2022 4105) 554 Fire alarm sounders (electronic) with facility to make announcement, mounted in M.S. Box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. (DSR E&M 2022 4106) 555 Fire alarm sounders (electronic) with facility to make announcement, mounted in A,B.S. Box with hinged cover plate & suitable for operation with amplifier l/c line matching ttransformer etc. (DSR E&M 2022 4107) 556 Talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. Knob & speaker/microphone enclosed in a M.S (16 SWG)/ABS.Box, break glass in front etc. (DSR E&M 2022 4108) 557 6 Zone fire alarm control panel as per IS: 2189 with backlit LCD (DSR E&M 2022 4110) 558 Cost of25 mm outer dia PVC/ABS Pipe with end caps including making air sampling operning of appropriate dia on appropriate interval. (DSR E&M 2022 4143) 559 Cost of fire survival armoured cable, fibre, fibre glass tape wrapped, ZH inner, outer sheath 2x1.5 sq. mm cable(DSR E&M 2022 4144) 560 Cost of fire alarm armoured FRLS cable 2 x 1.5 sqmm (DSR E&M 2022 4145) 561 Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required (DSR E&M 2022 19.1) 562 Concrete with 4cm gauge I class brick ballast, coarse sand (F.M. 1.8 to 2.5) and cement in proportion of 12:6:1 in foundations and under floors including supply of all materials, labour and tools and plants etc. required for proper completion. (CSI No.5.01 ) 563 Concrete work with 40 mm gauge brick ballast obtained from breaking brick bats (brick bats supplied by the department free of cost) in proportion of 12:6:1 as in CSI no. 5.01 including cost of all labour, materials, T&P etc required for proper completion of work. (CSI No. 5.20) 564 Brick work in foundation & plinth with old dismantled bricks (supplied by department free of cost) and coarse sand of F.M. 1.8 to 2.5 mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete. (CSI No. 6.18) 565 Brick work in Super structure with old dismantled bricks (supplied by department free of cost) and coarse sand of F.M. 1.8 to 2.5 mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete. (CSI No. 6.19) 566 S/F welded wire mesh size 75x25mm and rectangular made out of 10 SWG over M.S. angle frame with M.S. flat welded as required including cost of drilling holes, washer welding etc as required including cost of all material, labour and T&P etc. required for proper completion of work . exept cost of M.S angle and flat. (CSI No. 9.22) 567 Providing and laying SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. (CSI No. 27.29 c) 110 mm dia 568 Supply and Fixing of 3 blade wall fan of Havells platina 400 mm or equivalent including all material, T&P etc required for proper completion of work as approved by engineer in charge. (CSI No. 28.37) 569 Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havells or equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge.(CSI No. 28.38) 570 Supply & fixing steel tubular pole 7 Metre long designated 410 SP-2 in 1:3:6 cement concrete foundation including excavation back filling etc. complete in all respect. 2018 PWD 603 571 Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundationincluding the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. 2018 PWD 641 572 Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130 mm and base plate 12mm thik) having 3mm thikness with Double arm bracket (1 Mtr length) on RCC foundationincluding the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. 2018 PWD 642 573 Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 2018 PWD 1131 574 Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 2018 PWD 1131(A) 575 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 2018 PWD 1132 576 Same as in item no. 1132 but of 6..5 kg. capacity 2018 PWD 1132 (A) 577 Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge 2018 PWD 1133 578 Supply and fixing of power plug with 15A/250 voltflushtype switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mmsize with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. 2018 PWD 1139 579 Supply and fixing ofLED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect. 2018 PWD 1413(A)CAT AA 580 Supply and fixing ofLED Street light Fittinghaving die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt. Confirming to IP 66 protection complete in all respect. 2018 PWD 1421CAT AA 581 Supply and fixing ofLED Street light Fittinghaving die cast aluminium body and diffuser with driver set suitable for 175 to 200 Watt. Confirming to IP 66Protection complete in all respects.2018 PWD 1425(A)CAT AA 582 Supply and fixing of3 Watt LED Path / Walkover luminaire having powder cotated die cast aluminium body with drive set . Confirming to IP 65 Protection complete in all respect. 2018 PWD 1441CAT AAA 583 Supply and fixing of 3 Watt to 6 Watt LED Spot/Spike light luminaire Confirming to IP 66 Protection complete in all respect. 2018 PWD 1441 (A) CAT AAA 584 Supply and fixing ofdecorative 8 to 16 Watt LEDbollard luminaire with driver set confirming to IP 65 protection complete in all respect. 2018 PWD 1442CAT AAA 585 Supply and fixing ofdecorative 40 to 45 Watt LED Post top indirect light luminaire having Pressure die cast aluminium body and Clear glass with driver set confirming to IP 65 and aboveprotection complete in all respect.2018 PWD 1443CAT AAA 586 Supply and fixing of 450mm size Exhaust fan of approved quality ISI mark (Bajaj/Havells/Usha/Crompton or equivalent make) complete with all respect as per sample approved by Engineer in charge including supply of all materials, labour and T&P etc requried for proper completion of the work as direction of E/I complete. (NSI ) 587 S/F of LED Bulb 9Watt bajaj or equivalent make as approved sample and make as per direction of Engineer in charge (NSI) 588 Supply and fixing of 200 mm Turbo ventilator Fan with ss Chimneycap & pipe of approved quality ISI mark (Bajaj/Havells/Usha/Crompton or equivalent make) complete with all respect as per sample approved by Engineer in charge including supply of all materials, labour and T&P etc requried for proper completion of the work as direction of E/I complete. (NSI ) 589 Providing and fixing 15 mm thick Industrial tiles size 600 x 600 mm to of Johnson Endura Meteor or approved make and colour using in different sizes (thickness to be specified by the manufacturer) conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete(NSI) 590 20-25 mm thick fine dressed Red sand stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints finished flush.(NSI) 591 Providing/Laying 20-25 mm thick fine dressed Red sand stone flooring including supply of all materials, labour and T&P required for proper completion of work as perdirection of the Engineer-in charge.(NSI) 592 Providing and fixing prefab structure of size which does not require any structural steel frame at all heights of the existing building with following specifications: Manufactured by Epack polymers pvt ltd /Pronto panels Or Equivalent make.Walls: Outer & Inner walls made of 50 mm thick PUF insulated panels cladded with 0.5 mm thick PCGI sheet zinc coating 120 grams per sqm as per IS: 277. The wall panels shall be connected to each other with Cam Locks @ 1.00 m C/C The walls shall be connected to the the base platform with 1mm thick channels & 100 to 150mm long dash fasteners. The walls & ceiling shall be connected to each other by 1mm thick flashing as per the manufacturer specifications. Any number of vertical partitions are to be provided in the structure as required at site & as per the directions of the E-in-C complete. All the inner / outer gaps, if any, are to be filled with silicon, rubber gasket or any material required complete & directions of the Engineer in charge.Ceiling: Made of 50 mm thick PUF insulated panels cladded with 0.5 mm thick PCGI sheet zinc coating 120 grams per sqm as per IS: 277. The ceiling shall be extended from the wall on all sides by not less than 450mm & not more than 600mm with neccessary slopes in wall as required at the site & directions of the Engineer in charge complete. The outer edges of the roof shall be covered with the channel of the same material as of puff panel.Doors: Made out of 50 mm thick PUF insulated panels inner/outer side cladded with 0.5 mm thick PCGI sheet zinc coating 120 grams per sqm as per IS: 277. complete with providing & fixing all accessories like locks, SS hinges, SS Tower Bolts,SS handles of required size not more than 300mm.Windows: The frame work shall be of aluminium work (Powder coated aluminium (minimum thickness of powder coating 50 micron)) for doors, windows(Sliding/Openable as required with requisite handles, tower bolts,20mm dia SS curtain rod & any other fitting required ), ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be of thickness not less than 14gauge, smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing with 5.50mm thick glass / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. The outer surface shall have fly proof stainless steel grade 304 wire gauge, using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete .Strengthing of door, window, ventilators & any other opening : Any opening provided will have the framework strengthened with 1mm thick MS Plate on all sides all complete & directions of the Engineer in charge.Measurements: Only the floor area of the pre fab outer structure will be measured for payment purpose.Conditions Rates include all lifts, leads, depths, material, labour, scaffolding, all heights for location, carriage, wastage, tools and plants and other all inputs for execution of the item. The colour of the panels for walls & ceiling should be got approved from the E-in-C prior to start of manufacturing of the structure. The Structure requires approx five partitions in the two structures besides two outer walls . Note: The zinc sheet of the puff panels can either be plain/corrugated on both sides or one side plain & one side corrugated upto any pitch in horizontal / verticals per the drawings & requirement at site. 593 Supply,Installation, testing & commissioning Battery 12 V 7 AH Exide or equivalent make for above fire alarm system. Complete as per direction of the Engineer-in charge. 594 Supply,Installation, testing & commissioning Response Indicator Agni Suraksha or equivalent make. Complete as per direction of the Engineer-in charge. 595 Supply,Installation, testing & commissioning Camera (3 MP) colour W Audio IP Dome Secureye or equivalent Indian make ,Lens-3.6mm. Complete as per direction of the Engineer-in charge. 596 Supply,Installation, testing & commissioning Camera (2 MP) IP Dome Falcon series Secureye or equivalent Indian make ,Lens-3.6mm. Complete as per direction of the Engineer-in charge. 597 Supply,Installation, testing & commissioning NVR 8 channelSecureye or equivalent Indian make, with 4TBHDD Hard Disk. Complete as per direction of the Engineer-in charge. 598 Supply,Installation, testing & commissioning Connector D link or equivalent make Complete as per direction of the Engineer-in charge. 599 Supply,Installation, testing & commissioning 8 Port POE Switch Secureye or equivalent Indian make Complete as per direction of the Engineer-in charge. 600 Supply,Installation, testing & commissioning Cable (CAT6) D link or equivalent make Complete as per direction of the Engineer-in charge. 601 Servicing of Air Conditioner (For Window/Split) by aurthorised service center complete in all respect including all labour and T&P. (CSI No. 20.30) 602 Servicing of Air Conditioner and filling of GAS (For Window/Split) by aurthorised service center complete in all respect including all labour and T&P. (CSI No. 20.31) 603 Supply and fixing of recess/ Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver setcomplete in all respect. 1401 PWD CAT AA 604 Supply and fixing of recess/ Surface/ Pendent mounting round 10 to 15 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. 1402 PWD CAT AA 605 Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect.1406 PWD CAT AA 606 P/F of 30 W orevo make or equivalent make LED light 30 Watt over Hoarding frame along boundary wall of MD DVVNL Campus, 220 KV S/S Sikandra , Agra with necessary materials , labour, T&P etc required for proper completion of the work as per direction of Engineer in charge. (NSI) 607 Providing and fixing of 20 W Philips make or equivalent make LED Tube light 20 Watt with necessary materials labour, T&P etc requried for proper completion of the work as per direction of Engineer in charge (NSI) 608 S/F of 07 Watt LED bulb Syska or other equivalent make including cost of labour, T&P etc required for proper completion of the work (NSI) 609 Supply and fixing of vertical blinds with hanging/sliding rod of aluminium (vista or equivalent make), vertical cord for operation of blinds, L-type hooks, screws, gullies etc. including all T&P, labour etc required for proper completion of the work in all respect. (NSI) 610 Printing name and designation of occupants and other information on residence block/office building including preparation of the base with best quality synthetic enamel paint as directed by E/I including cost of all materials, labour and T&P etc. required for proper completion of work. (NSI) 611 Providing and fixing of Name plate Acrylic/Glow sign Sheet per mm thick without letter as per approved shade and design as per direction of Engineer in charge (NSI) 612 Providing and Pasting of Name plate letter cutting words laser machine without name plate including cost of necessary all fittings such as nut, screws, labour T&P etc requried for proper completion of the work as per direction of Engineer in charge (NSI)
Contract Date: Apr 23, 2026 Contract Value : 21.94 Lakh
Government Departments No of Bidders 3
Uttar Pradesh View Result →
31.
Educational and Research Institute #10163704 Price Bid
Supply Of Library Books And Journals , Medical Education Unit , Books Name : Communication Skills In Clinical Practice ( Doctor Patient Communication ) Publisher / Writer : Sethuraman K.R , Books Name : Reflective Teaching And Learning In The Health Professions Publisher / Writer : Kember , Books Name : Medical Education In India Today Publisher / Writer : Ima , Books Name : The Evaluation Teaching In Medical Schools Publisher / Writer : Rippey Robert , Books Name : How To Design A Problem Based Curriculum Publisher / Writer : Barrowsowards , Books Name : Assessment In Medical Education Publisher / Writer : Sood Rita , Books Name : Implementing Problem-Based Medical Education Publisher / Writer : Kaufman Arthur , Books Name : The Medial Teacher Publisher / Writer : Cox Kenneth R , Books Name : A Practical Guide For Medical Teacher Publisher / Writer : Dent John A , Books Name : Basic In Medical Education Publisher / Writer : Amin Zubair , Radiotherapy , Books Name : Principles And Practices Of Radiation Oncology ( 7Th Edition ) Publisher / Writer : Perez And Brady , Books Name : Devita, Hellman, And Roseberg’S Cancer Principles And Practice Of Oncology ( Vol-1 And Vol-2 ) 8Thedition. Publisher / Writer : Devita, Hellman, And Roseberg , Community Medicine , Book Name : Public Health And Preventive Medicine - The Red Book, Author: Rajvir Bhalwar Publisher :Afmc, Pune In Collaboration With Who India Office, New Delhi Edition : Latest , Book Name : Textbook Of Community Medicine Author: Rajvir Bhalwar Publisher :Wolters Kluwer Edition : 2Nd , Book Name : Parks Text Book Of Preventive & Social Medicine Author: K. Park Publisher :Banarsidas Bhanot Edition : Latest , Book Name : Textbook Of Community Medicine: Preventive And Social Medicine Author: Sunder Lal Publisher :Cbs Publishers & Distributors Edition : Latest , Book Name : Community Medicine With Recent Advances Author: Ah Suryakantha Publisher :Jaypee Medical Edition : Latest , Book Name : Maxey-Rosenau-Last Public Health And Preventive Medicine Author: Robert B. Wallace Publisher :Jaypee Medical Edition : Latest , Book Name : Oxford Textbook Of Public Health Author: Roger Detels Publisher :Oxford University Press, Usa Edition : 5Th , Book Name : The Theory And Practice Of Public Health Author: William Hobson Publisher :Oxford Med. Publication Edition : 5Th , Book Name : Mahajan & Gupta Textbook Of Preventive And Social Medicine Author: Mahajan B K And M.C. Gupta Publisher :Jaypee Edition : Latest , Book Name : Textbook Of Community Medicine ( Preventive & Social Medicine ) Author: Piyush Gupta Publisher :Cbs Publishers & Distributors Edition : Latest , Book Name : Foundations Of Community Medicine Author: G. M. Dhaar Publisher :Elsevier India Edition : Latest , Book Name : A Comprehensive Textbook Of Community Medicine: Preventive And Social Medicine Author: J S Mathur Publisher :Cbs Edition : Latest , Book Name : Principles & Practice Of Community Medicine Author: Asma Rahim Publisher :Jaypee Brothers Medical Publishers Edition : 2Nd , Book Name : Mcwhinneys Textbook Of Family Medicine Author: Thomas R. Freeman Publisher :Oxford Edition : 4Th , Book Name : Textbook Of Community And Social Pediatrics Author: Sr Banerjee Publisher :Jaypee Brothers Medical Publishers Edition : Latest , Book Name : Epidemiology-Principles And Methods Author: Brian Macmahon Publisher :Lippincott Williams And Wilkins Edition : Latest , Book Name : Gordis Epidemiology Author: David D Celentano, Moyses Szklo Publisher :Elsevier Edition : 6Th / Latest , Book Name : Epidemiology: Concepts And Methods Author: William A. Oleckno Publisher :Waveland Press Edition : Latest , Book Name : Basic Epidemiology Author: Beaglehole R, Bonita R Publisher :World Health Organization, Geneva Edition : Latest , Book Name : A Dictionary Of Epidemiology Author: Miquel Porta Publisher :Oxford University Press Edition : 6Th , Book Name : Medical Epidemiology ( Lange Basic Science ) Author: Author: Author: Raymond Greenberg Publisher :Mcgraw-Hill Medical Edition : Latest , Book Name : Modern Epidemiology Author: Rothman, Kenneth J Publisher :Lippincott Williams & Wilkins Edition : 3Rd / Latest , Book Name : Epidemiology: An Introduction Author: Kenneth J. Rothman Publisher :Oxford University Press Edition : 2Nd / Latest , Book Name : Modern Infectious Disease Epidemiology Author: Johan Giesecke Publisher :Crc Press Edition : 3Rd , Book Name : Hospital Epidemiology & Infection Control Author: C. Glen Mayhall Publisher :Lipincot Williams & Wilkins Edition : 4Th , Book Name : Primer Of Epidemiology Author: Gary Friedman Publisher :Mcgraw-Hill Education / Medical Edition : Latest , Book Name : Clinical Epidemiology: How To Do Clinical Practice Research Author: R. Brian Haynes Publisher :Lippincott Williams And Wilkins Edition : Latest , Book Name : Epidemiology & Management For Health Care Author: P. V. Sathe , P. P. Doke Publisher :Vora Medical Publications Edition : Latest , Book Name : Jekels Epidemiology, Biostatistics, Preventive Medicine, And Public Health Author: David L. Katz & Joann G. Elmore Publisher :Elsevier Saunders Edition : 4Th / Latest , Book Name : Practical Epidemiology Author: Barker D J P, Hall Publisher :Churchill Livingstone Edition : Latest , Book Name : A Short Introduction To Epidemiology Author: Neil Pearce Publisher :Wellington, N.Z. Edition : Latest , Book Name : Mausner & Bahn Epidemiology: An Introductory Text Author: Mausner & Kramer Publisher :W. B. Saunders Company Edition : Latest , Book Name : Principles Of Medical Statistics Author: Bradford Hill Publisher :Hodder Arnoldedition : Latest , Book Name : Medical Statistics: A Textbook For The Health Sciences Author: David Machin Publisher :Cbs Publishers & Distributors Edition : Latest , Book Name : Mahajans Methods In Biostatistics For Medical Students And Research Workers Author: Bratati Banerjee Publisher :Jaypee Edition : Latest , Book Name : Simple Biostatistics For Mbbs, Pg Entrance And Usmle Author: Indrayan A, Satyanarayana L Publisher :Academa Publishers Edition : Latest , Book Name : Sample Size Determination In Health Studies: A Practical Manual Author: S.K. Lwanga Publisher :Who, Geneva Edition : Latest , Book Name : Basic Methods Of Medical Research Author: Abhaya Indrayan Publisher :Aitbs Publishers Edition : Latest , Book Name : Introduction To Biostatistics And Research Methods Author: Sunder Rao Publisher :Phi Learning Pvt. Ltd Edition : Latest , Book Name : Statistics For Management Author: Levin, Rubin Publisher :Pearson Education Edition : 8Th / Latest , Book Name : Principles Of Biostatistics Author: Marcello Pagano Publisher :S.Chand ( G / L ) & Company Edition : Latest , Book Name : Fundamentals Of Biostatistics Author: Bernard Rosner Publisher :Cengage Learning Edition : Latest , Book Name : Public Health Administration And Practice Author: John J. Hanlon Publisher :Mosby Edition : Latest , Book Name : Hospitals And Nursing Homes: Planning, Organisations And Management Author: Tabish Syed Amin Publisher :Jaypee Edition : Latest , Book Name : Health Care System & Management Author: S L Gohel Edition : Latest , Book Name : Essentials Of Management Author: Massie Publisher :Prentice Hall India Learning Edition : Latest , Book Name : Medical Record Organization & Management Author: G.D. Mogli Publisher :Jaypee Edition : Latest , Book Name : The Hospital Administrator Author: M A George Publisher :Jaypee Edition : Latest , Book Name : Hospital Administration Author: Francis Publisher :Jaypee Edition : Latest , Book Name : Primary Health Care Management Advancement Program Author: Jack Reynolds Publisher :Aga Khan Foundation Edition : Latest , Book Name : Modern Nutrition In Health & Disease Author: A. Catharine Ross Publisher :Lippincott Williams And Wilkins Edition : Latest , Book Name : Manual Of Nutrition Therapeutics Author: Alpers Publisher :Wolters Kluwer Edition : Latest , Book Name : Human Nutrition & Dietetics Author: Js Garrow Publisher :Churchill Livingstone Edition : Latest , Book Name : Protein Energy Malnutrition Author: J. C. Waterlow Publisher :Hodder Arnold Edition : Latest , Book Name : Dietary Guidelines For Indians – A Manual Author: Nin Publisher :National Institute Of Nutrition Edition : Latest , Book Name : Hunters Diseases Of Occupations Author: Peter J Baxter Publisher :Hodder Arnold Edition : 10Th / Latest , Book Name : National Health Programmes Of India Author: Jugal. Kishore Publisher :Century Publications Edition : Latest , Book Name : Dk Taneja’S Health Policies & Programmes In India Author: Bratati Banerjee Publisher :Jaypee Edition : Latest , Book Name : A Dictionary Of Public Health Author: Jugal. Kishore Publisher :Century Publications Edition : Latest , Book Name : Medical Entomology For Students Author: Mike Service Publisher :Cambridge University Press Edition : Latest , Book Name : A Text Book Of Entomology Author: R Mathur Publisher :Campus Books International Edition : Latest , Book Name : The Sage Handbook Of Social Research Methods Author: Pertti Alasuutari Publisher :Sage Publications Ltd Edition : Latest , Book Name : Social Research Methods Author: Alan Bryman Publisher :Oup Oxford Edition : Latest , Book Name : A Review Of Preventive And Social Medicine Author: Chandrakant Lahariya Publisher :Jaypee Edition : Latest , Book Name : Roses Strategy Of Preventive Medicine Author: Geoffrey Rose Publisher :Oup Oxford Edition : Latest , Book Name : Vaccinated: One Mans Quest To Defeat The Worlds Deadliest Diseases Author: Paul A. Offit Publisher :Harper Perennial Edition : Latest , Book Name : Inside The Outbreaks: The Elite Medical Detectives Of The Epidemic Intelligence Service Author: Mark Pendergrast Publisher :Mariner Books Edition : Latest , Book Name : Tobacco: A Global Threat Author: John Crofton And David Simpson Publisher :Macmillan Education Edition : Latest , Book Name : House On Fire: The Fight To Eradicate Smallpox Author: William H Foege Publisher :University Of California Press Edition : Latest , Book Name : Basic & Clinical Biostatistics Author: Beth Dawson, Robert G. Trapp Publisher :Mcgraw-Hill Medical ( Lange ) Edition : Latest , Book Name : Introductory Applied Biostatistics Author: Sr. Ralph Dagostino Publisher :Cengage Learning Edition : Latest , Book Name : Intuitive Biostatistics: A Nonmathematical Guide To Statistical Thinking Author: Harvey Motulsky Publisher :Oxford ( Oup Usa ) Edition : Latest , Book Name : Programmed Statistics ( Question-Answers ) Author: B.L. Agarwal Publisher :New Age Edition : Latest , Book Name : Foundations Of Epidemiology Author: David E. Lilienfeld Publisher :Oxford ( Oup Usa ) Edition : Latest , Book Name : Epidemiology In Medicine Author: Charles H. Hennekens Publisher :Little, Brown And Co Edition : Latest , Book Name : Methods For The Economic Evaluation Of Health Care Programmes Author: Michael F. Drummond Publisher :Oup Uk ( Oxford ) Edition : Latest , Book Name : Clinical Epidemiology: The Essentials Author: Robert Fletcher Publisher :Lippincott Williams And Wilkins Edition : Latest , Book Name : Studying A Study And Testing A Test: Reading Evidence-Based Health Research Author: Richard K. Riegelman Publisher :Lippincott Williams And Wilkins Edition : Latest , Book Name : Statistics In Small Doses Author: Winfred M Castle Publisher :Churchill Livingstone Edition : Latest , Book Name : Ghai Essential Pediatrics Author: Vinod K. Paul Publisher :Cbs Publishers Edition : Latest , Book Name : Dc Dutta’S Textbook Of Obstetrics Author: Hiralal Konar Publisher :Jaypee Edition : Latest , Book Name : Essentials Of Community Medicine Practicals Author: Dk Mahabalaraju Publisher :Jaypee Edition : Latest , Book Name : Community Medicine: Practical Manual Author: Rajkumar Patil Publisher :Elsevier Edition : Latest , Book Name : Community Medicine Practical Guide Author: Kusum Lata Gaur Publisher :Cbs Publishers Edition : Latest , Book Name : Nutritive Value Of Indian Foods Author: C Gopalan Publisher :National Institute Of Nutrition ( Icmr ) Hyderabad Edition : Latest , Book Name : Dietetics Author: B Srilakshmi Publisher :New Age International Private Limited Edition : Latest , Book Name : Fundamentals Of Human Nutrition Author: Catherine Geissler Publisher :Elsevier, Churchill Livingstone Edition : Latest , Book Name : Research Methods In Coomunity Medicne Author: Jh Abramson Publisher :John Willey & Sons Edition : Latest , Book Name : Iapsm”S Textbook Of Community Medicine Author: Am Kadri ============ Edition : Latest , Opthalmology , Book Name :- Kanski’S Clinical Ophthalmology Edition / Publisher: 9Th Author: Kanski & Bowling , Book Name :- Person’S Diseases Of Eye Edition / Publisher: 23Rd Author: Ramanjit Sihota & Radhika Tendon , Book Name :- Comprehensive Ophthalmology Edition / Publisher: 7Th Author: Ak Khurana , Book Name :- Shield’S Textbook Of Glaucoma Edition / Publisher: 7Th Author: R. Rand Allingham , Book Name :- A Manual Of Systematic Eyelid Surgery Edition / Publisher: 3Rd Author: J.R.O Collin , Book Name :- Recent Advances In Ophthalmology Edition / Publisher: 12Th Author: H.V Neema & Nitin Neema , Book Name :- Recent Advances In Ophthalmology Edition / Publisher: 13Th Author: H.V Neema & Nitin Neema , Book Name :- Recent Advances In Ophthalmology Edition / Publisher: 14Th Author: H.V Neema & Nitin Neema , Book Name :- Recent Advances In Ophthalmology Edition / Publisher: 15Th Author: H.V Neema & Nitin Neema , Book Name :- Springer Cataract & Refractive Surgery Edition / Publisher: Author: Thomas Khonen , Book Name :- Practical Handbook Of Oct Edition / Publisher: 3Rd Author: Bruno Lumbroso & Marco Rispoli , Book Name :- The Lacrimal System Edition / Publisher: 2Nd Author: Adam J., Cohen, Brain & Brazzo , Book Name :- Colour Atlas & Synopsis Of Clinical Ophthalmology ( Retina ) Edition / Publisher: 3Rd Author: Mitchell S Fineman & Allen C. Ho , Book Name :- Theory And Practice Of Optics & Refraction Edition / Publisher: 4Th Author: Ak Khurana & Indu Khurana , Book Name :- Anatomy & Physiology Of Eye Edition / Publisher: 3Rd Author: Ak Khurana & Indu Khurana , Book Name :- Yonoff Of Ophthalmology Edition / Publisher: 5Thauthor: Myron Yanoff & J.S Duker , Book Name :- Peyman’S Principles & Practice Of Ophthalmology Edition / Publisher: 2Nd Author: N.Venkatesh Prajna , Book Name :- Duke Elder’S Practice Of Refraction Edition / Publisher: 10Th Author: David Abrams , Book Name :- Post Graduate Ophthalmology Edition / Publisher: Vol. 2 Author: Zia Chaudhuri & M. Vanathi , Book Name :- Handbook Of Ophthalmology, 6E Edition / Publisher: Cbs Author: Chatterjee B.M. , Book Name :- Surgical Ophthalmic Oncology ( Hb ) Edition / Publisher: Springer Author: Chaugule , Book Name :- Handbook Of Emergency Ophthalmology ( Pb ) Edition / Publisher: Springer Author: Long , Book Name :- Surgical Techniques In Ophthalmology Oculoplastic Surgery ( Hb ) Edition / Publisher: Elsevier Science ( Medical ) Author: Long , Book Name :- Ophthalmology: Oral Board Review ( Pb ) Edition / Publisher: Lippincott Author: Luviano , Book Name :- Rapid Diagnosis In Ophthalmology Series: Anterior Segment ( Pb ) Edition / Publisher: Elsevier Science ( Medical ) Author: Macsai , Book Name :- Clinical Techniques In Ophthalmology ( Hb ) Edition / Publisher: Elsevier Science ( Medical ) Author: Madge , Book Name :- Wills Eye Institute 5 Minute Ophthalmology Consult ( Hb ) Edition / Publisher: Lippincott Author: Maguire J I , Microbiology , Title / Book Name :- Parasitology : Protozoology And Helminthology Author:Chatterjee Publisher: Cbs , Title / Book Name :- Practical Microbiology For Under Graduate Medical Students Author:Parija Publisher: Ahuja , Title / Book Name :- Practical And Viva In Medical Microbiology Author:Randhawa Publisher: R.E , Title / Book Name :- Textbook Of Medical Mycology Author:Chander Jagdish Publisher: Jaypee , Title / Book Name :- Textbook Of Medical Parasitology Protozoology And Helimthology Author:Parija Publisher: Aipd , Title / Book Name :- Textbook Of Medical Parasitology Author:Chakraborty Publisher: Ncba , Title / Book Name :- Topley And Wilson’S Microbiology And Microbial Infections Author:Topley Publisher: Wiley , Title / Book Name :- A Text Book Of Microbiology Author:Chakraborty Publisher: Ncba , Title / Book Name :- Ananthanarayan And Paniker’S Text Book Of Microbiology Author:Kanungo Publisher: University Press , Title / Book Name :- Antibiotic Manual : A Guide To Commonly Used Antimicrobials Author:Schlosseberg Publisher: Pmph , Title / Book Name :- Dengue Virus ( Current Topics In Microbiology And Immunology ) Author:Publisher: Springer , Title / Book Name :- Ebola Virus Diseases From Origin To Outbreak Author:A Qureshi Publisher: Ap , Title / Book Name :- Emergency Management Of Infection Diseases, 2 / Ed ( Excel. Abc ) Author:Chin Publisher: Cambridge , Title / Book Name :- Essential Of Medical Microbiology 2 / Ed Author:Sastry & Bhat Publisher: Jaypee , Title / Book Name :- Essential Of Microbiology And Immunology Author:Mohanty Publisher: Paras , Title / Book Name :- Fever Of Unkonwn Origin ( Infection Diseases And Therapy ) Author:Kevin Parker Publisher: Callisto , Title / Book Name :- Food Borne Viruses: Progress And Challenges ( Hb ) Author:Koopmans Publisher: Asm , Title / Book Name :- Immunology For Medical Students Author:Helbert Publisher: Elsevier , Title / Book Name :- Infection Control Handbook Author:Tyler Smith Publisher: Hayle , Title / Book Name :- Infection Prevention And Control Author:Elliott Publisher: Radcliffe , Title / Book Name :- Mackie & Mccartney Practical Medical Microbiology Author:Collee Publisher: R.E , Title / Book Name :- Mannual Of Clinical Microbiology Author:Murray Publisher: Asm , Title / Book Name :- Essentials Of Microbiology, 2E ( Pb ) Author:Anuradha De Publisher: Cbs ( National ) , Title / Book Name :- Practical And Applied Microbiology, 5E ( Pb ) Author:Anuradha De Publisher: Cbs ( National ) , Title / Book Name :- Advances In Microbiology, Infectious Diseases And Public Health, Vol.1 ( Hb ) Author:Donelli Publisher: Springer , Title / Book Name :- Advances In Microbiology, Infectious Diseases And Public Health, Vol.2 ( Hb ) Author:Donelli Publisher: Springer , Title / Book Name :- Advances In Microbiology, Infectious Diseases And Public Health, Vol.4 ( Hb ) Author:Donelli Publisher: Springer , Ent , Author:- Donald Murphy Title: A Clinician*S Guide To Otolaryngology Publisher: Foster , Author:- Parker Title: Allergic Rhinitis Publisher: Hayle , Author:- Lore Title: An Atlas Of Head And Neck Surgery, 4E ( Cbs Ex. ) Publisher: Elsevier , Author:- Staloff Title: Atlas Of Endoscopic Laryngeal Surgery Publisher: Jaypee , Author:- Ulug Title: Atlas Of Temporal Bone Surgery Publisher: Thieme , Author:- Yoshioka Title: Atlas Of The Facial Nerve And Related Structures.1 / E Publisher: Thieme , Author:- Michael Title: Audiology Treatment Publisher: Thieme , Author:- Roudolfprobst Title: Basic Otorhinolarygology A Step By Step Learning Guide Publisher: Thieme , Author:- Malhotra Title: Challengs In Otorhinolaryngology Publisher: Jaypee , Author:- Davidson Title: Clinical Manual Of Otolaryngologyy Publisher: Jaypee , Author:- Soni Title: Clinical Cases In Otolaryngology Publisher: Japee , Author:- Hughes Title: Clinical Otology Publisher: Thieme , Author:- Adambachman Title: Clinical Research In Rhinoplasty Publisher: Foster , Author:- Waltzman Title: Cochlear Implants 3 / Ed Publisher: Thieme , Author:- Bernal Sprekelsen Title: Complication In Otololary Geology Head And Neck Surgery 1 / E Publisher: Thieme , Author:- Pensak Title: Contraversies In Otolaryngolog Publisher: Thieme , Author:- Flint Title: Cummings Otolarybgology Head And Neck Surgery 3 Volume Set International Edition 7E Publisher: Elsevier , Author:- Sun Title: Diagonosis And Management Of Head And Face Pain A Practical Approach Publisher: Springer , Author:- Kanegaonkartitle: Dizziness And Vertigo An Intoduction And Practic Al Guide Publisher: Crc , Author:- Groher Title: Dysphagia Clinical Management In Adult And Childern And 2E Publisher: Mosby , Author:- Sahoo Title: Emergencies In Otorhinolarygology Publisher: Jaypee , Author:- Casiano Title: Endoscopic Sinonasal Dissection Guide / 1E Publisher: Thieme , Author:- Wormald Title: Endoscopic Sinus Surgery Publisher: Thieme , Author:- Chaddowns Title: Essential Otolaryngology Publisher: Foster , Author:- Behrbohm Title: Essential Of Septrohinoelasty Philosophy Approach Technique Publisher: Thee , Author:- Gavilan Title: Functional And Slective Neck Dissection Publisher: Thee , Author:- Schkrtz Title: Hand Book Of Child Language Disorder Publisher: Psychology Press , Author:- Katz Title: Hand Book Of Clinical Audiology 7Ed Publisher: Lww , Author:- Shahjatin Title: Jatin Shah Head And Neck Surgery And Oncology 5 / Ed Publisher: Elsevier , Author:- Kendall Title: Laryngeal Evaluation ( Excl Abc ) Publisher: Thieme , Author:- Dhingra Title: Disease Of Ear Nose And Throat Head And Neck Surgery 7E Publisher: Elsevier , Author:- Brennan Title: Maxillofacial Surgery 3 / Ed Two Volumes Publisher: Elsevier , Author:- Roland Title: Ototoxicity Publisher: Bc Decker , Author:- Kirtane Title: Pediatric Otorhinolartngology Diagnosis And Treatment: Otolaryngology – Head And Neck Surgery Series ( Excl.Abc ) Publisher: Thieme , Author:- Schnorrenbeger Title: Pocket Atlas Of Tongue Diagnosis Publisher: Thieme , Author:- Swan Title: Practical E.N.T ( Pb ) ( * ) Publisher: Aitbs , Author:- Prabhat Title: Practical E.N.T, 10E ( Pb ) Publisher: Cbs , Author:- Vasan Title: Surgery With Dvd-Rom Publisher: Jaypee , Author:- Myers Title: Slivary Gland Disorders Publisher: Springer , Author:- Watkinson Title: Scott-Browns’S Otorhinolaryngology And Head And Neck Surgery 8 / Ed, 3 Vols Set Publisher: T & F , Author:- Hormann Title: Surgery For Sleep Disordered Breathing With Dvd-Video Publisher: Springer , Author:- Dispenza Title: Textbook Of Vertigo Diagnosis And Management Publisher: Jaypee , Author:- Peterson-Falzone Title: The Clinician’S Guide To Treating Cleft Plate Speech, 2 / Ed Publisher: Springer , Author:- Bagulery Title: Tinnitus: A Multidisciplinary Approach, 2Ed Publisher: Springer , Author:- Barnes Title: Surgical Pathology Of The Head & Neck, 3E, 3 Vol. Set ( Hb ) Publisher: Taylor & Francis ( Informa ) , Author:- Bass Title: Hearing And Hormones ( Hb ) Publisher: Springer , Author:- Batra Title: Practical Medical And Surgical Management Of Chronic Rhinosinusitis ( Hb ) Publisher: Springer , Author:- Battle Title: Communication Disorders In Multicultural And International Populations, 4E ( Hb ) Publisher: Elsevier Science ( Medical ) , Author:- Behrbohm Title: Essentials Of Septorhinoplasty, 2E ( Hb ) Publisher: Thieme , Author:- Behrbohm Title: The Nose-Revision & Reconstruction: A Manual And Casebook ( Hb ) Publisher: Thieme , Author:- Bell Title: Oral, Head And Neck Oncology And Reconstructive Surgery ( Hb ) Publisher: Elsevier Science ( Medical ) , Author:- Berkovitz Title: Head & Neck Anatomy: A Clinical Reference ( Hb ) Publisher: Taylor & Francis ( Informa ) , Author:- Bernal-Sprekelsen Title: Endoscopic Approaches To The Paranasal Sinuses And Skull Base ( Hb ) Publisher: Thieme , Author:- Bernal-Sprekelsen Title: Transoral Laser Microsurgery Of Benign And Malignant Lesions ( Hb ) Publisher: Thieme , Anesthesiology , Author Keithg.Allman & Lain H. Willson Title Oxford Handbook Of Anesthesia Publisher Oxford University Press , Author Morgan & Mikhail’S Title: Anesthesiology Cases Publisher:- Mc Graw-Hill , Author Michael A. Gropper Title: Miller’S Anesthesia Publisher:- Elsevier , Author Wylie And Churchill-Davidson’S Title: A Practice Of Anesthesia Publisher:- Crc Press , Author Paul G. Barash, Cullen, Christine Stock & Others Title: Clinical Anesthesia Publisher:- Walter’S Kluwer , Author Paul Marino’S Title: The Icu Book Publisher:- Walter’S Kluwer , Author Jameson, Fauci & Others Title: Harrison’S Principle’S Of Internal Medicine Publisher:- Mc Graw-Hill , Author Ajay Yadav Title: Short Text Book Of Anesthesia Publisher:- Jay Pee Publishers , Author Yao & Artusi Title: Anesthesiology Problem Oriented Patient Management Publisher:- Walter’S Kluwer , Author John R.Hampton Title: The Ecg Made Easy Publisher:- Elsevier , Author Roberta L. Hines & Katherin E. Marschall Title: Stoelting Anesthesia And Co-Existing Disease Publisher:- Elsevier , Author Arthurs Title: Anesthesia A Concise Handbook ( Excl .Abc ) Publisher:- Gmm , Author Yentis Title: Anesthesia And Intensive Care A-Z; An Encyclopedia Of Principles And Practice, Six / Ed Publisher:- Elsevier , Author Longnecker Title: Anesthesiology 3 / Ed Publisher:- Mgh , Author Fischer Title: Atlas Of Injection Thearpy In Pain Management Publisher:- Theime , Author Chestnutt Title: Chestnutt’S Obstereics Anesthesia Principles And Practice 6 / Ed Publisher:- Elesvier , Author Barash Title: Clinical Aneshteisa Fundamentals Publisher:- W.K , Author Solh Title: Critical Care Management Of The Obese Patient ( Hb ) Publisher:- Wiley , Author Paul Title: Drugs And Equipments In Anesthetic Practice, 6E Publisher:- R.E , Author Na Title: Emergency Airway Management Publisher:- Cambridge , Author Schmidt Title: Encyclopedia Of Pain, Volume 3 Publisher:- Springer , Author Collier Title: Epidural Anesthesia Images, Problems And Solutions Publisher:- Hodder , Author Mccann Title: Essentials Of Anesthesia For Infants And Neonates Publisher:- Cambridge , Author Prabhakar Title: Essentials Of Geriatric Neuro Anesthesia Publisher:- Crc , Author Kaplan Title: Kaplan’S Essentials Of Cardiac Anesthesia, 2 / Ed Publisher:- Elsevier , Author Langford Title: Key Clinical Topics In Anesthesia Publisher:- Jaypee , Author Cashman Title: Lee’S Synopsis Of Anesthesia, 14E Publisher:- R.E , Author Marino Title: Marino’S The Icu Book 4Ed Publisher:- W.K , Author Miller Title: Miller’S Anestheisa, 9 / Ed, Volume 2, ( Ie ) Publisher:- Elsevier , Author Evan Short Title: Monitoring In Anesthesia And Critical Care Publisher:- Foster , Author Singer Title: Oxfordhandbook Of Critical Care , 3Ed Publisher:- Oxford , Author Lit Man Title: Pediatric Anesthesia Paractice.. Pocket Clinician Publisher:- Cambridge , Author Fuhrman Title: Pediatric Critical Care , 5E Publisher:- Elsevier , Author Reach Title: Perioperative Pain Management For Orthopaedics And Spine Surgery Publisher:- Oxford , Author Edited By Johan Raeder, Richard D Urman Title: Practical Ambulatory Anesthesia Publisher:- Cup , Author Chaney Title: Regional Anesthesia For Cardiothoracic Surgery Publisher:- Lww , Author Jeff Gadsden Title: Regional Anesthesia In Trauma Publisher:- Cup , Author Pamela Flood Title: Stoelting’S Pharmacology And Physiology In Anesthetic Practice, 5 / E Publisher:- W.K , Author Jacob Title: Understanding Pediatrics Anesthesia, 3 / E Publisher:- W.K , Author Healy Title: Wylie And Churchill Davidson’S ..A Practice Of Anesthesia, 7 / Ed Publisher:- Hodder , Author Yao Title: Yao And Artusio’S Anesthesiology, 8 / Ed Publisher:- W.K , Radiology , Title / Book Name Imaging Of Fetal Brain And Spine Author Rama Murthy Edition & Publisher / Year Latest Edition 2019 , Title / Book Name First Trimester Ultrasound Diagnosis Of Fetal Abnormalities Author Rabih Chaoui / Abuhamad Edition & Publisher / Year Latest Edition, 2018 , Title / Book Name A Practical Guide To Fetal Echocardiography Normal And Abnormal Hearts Author Rabih Chaoui / Abuhamad Edition & Publisher / Year 3Rd 2016 , Title / Book Name 3D Ultrasound In Prenatal Diagnosis A Practical Approach Author Rabih Chaoui Edition & Publisher / Year 2016 , Title / Book Name Obstetric Imaging: Fetal Diagnosis And Care Author Copel Edition & Publisher / Year 2Nd 2017 , Title / Book Name Ultrasound Of Congenital Fetal Anomalies Author Paladini Edition & Publisher / Year 2Nd 2019 , Title / Book Name Ultrasonography Of The Prenatal Brain Author Timor- Tristch, Monteagudo. Piu, Malinger Edition & Publisher / Year 3Rd , Title / Book Name Isuogjournal Author Edition & Publisher / Year Latest Edition , Title / Book Name Diagnostic Imaging Series Gynaecology, Genitourinary, Oral, Maxillofacial, Head , Neck, Musculoskeletal, Chest Radiography Author Elsevier Edition & Publisher / Year Latest Edition , Title / Book Name Callen’S Ultrasound In Obstetrics And Gynaecology Author Norton Edition & Publisher / Year 2017 , Title / Book Name 3D Ultrasound In Prenatal Diagnosis A Practical Approach Author Chaoui Edition & Publisher / Year 2016 , Title / Book Name Ultrasound Diagnosis Offetal Anomalies Author Entezami Edition & Publisher / Year 2004 , Title / Book Name Ct Andmri Of The Whole Body Author Haaga Edition & Publisher / Year 6Th 2-Volumes Set 2016 , Title / Book Name Diagnostic Breast Imaging Author Heywang Edition & Publisher / Year 3Rd 2014 , Title / Book Name Pediatric Imaging / Doppler Ultrasound Of The Chest Author Hutha Edition & Publisher / Year 1986 , Title / Book Name Diagnostic Imaging Ultrasound Author Jackson Edition & Publisher / Year 2017 , Title / Book Name Breast Imaging Author Maidment Edition & Publisher / Year 2012 , Title / Book Name Fetal Medicine: Basic Science And Clinical Practice Author Pandya Edition & Publisher / Year 3Rd Hb 2020 , Title / Book Name Diagnostic Ultrasound Author Rumack C.M. Edition & Publisher / Year 5Th , 2 Vol Sets, 2018 , Title / Book Name Fetal And Neonatal Brain Injury Author Stevenson Edition & Publisher / Year 4Th 2009 , Title / Book Name Ultrasound Scanning Principles And Protocols Author Tempkin Edition & Publisher / Year 3Rd 2009 , Department Of Hospital Management , Title / Book Name Hotel, Hostel And Housekeeping Author Edition5th , Title / Book Name Textbook Of Hospital Housekeeping Author Edition Latest Edition , Title / Book Name A Handbook On Housekeeping And Disinfection Practices For Healthcare Facilities Author Shakti Kumar Gupta, Sunil Kant, P Kumar Edition 50Th , Title / Book Name Introduction To Fire Safety Management Author Andrew, Martin Edition Latest Edition , Title / Book Name Fire Safety Plan For Hospitals Author Dr Mani Kumar Editionlatest Edition , Title / Book Name Hospital Waste Management And Its Monitoring Author Madhuri Sharma Edition 2Nd , Title / Book Name Manual Of Fire Safety Author Edition Latest Edition , Title / Book Name Mcq’S In Management And Hospital Administration Author Shakti Kumar Gupta, Sunil Kant Edition Latest Edition , Title / Book Name Hospital Administration Principles 7 Practice Author Yashpal Sharma Edition Latest Edition , Title / Book Name Hospital Administration & Human Resource Management Author D K Sharma R C Goyal Editionlatest Edition , Title / Book Namenursing Services And Administration Authorneelam Kumara, Madhu Sharma Edition Latest Edition , Title / Book Name A Textbook Of Administration And Ward Management Authorneelak Kumari, Madhu Sharma Edition Latest Edition , Title / Book Name Nursing Research & Statistics Author Suresh K. Sharma Edition 3Rd , Title / Book Name Management Of Nursing Services And Education Author Clement Edition 2Nd , Title / Book Name A Comprehensive Textbook Of Nursing Management Authordeepak K, Sarath Chandran Editionlatest Edition , Title / Book Name Introduction To Nursing Service Administration Author Shabnam Masih Edition Latest Edition , Title / Book Name Nursing Administration Author Bt Basvanthappa Edition 3Rd , Title / Book Name Nursing Administration And Management Author Sunita Joseph Edition Latest Edition , Title / Book Name Ward Management & Administration For Nurses Author Manjubala Dash Edition Latest Edition , Title / Book Name Principles And Practice Of Nursing Management Administration For Bsc And Msc Nursing Author Jogindra Vati Edition 2Nd , Title / Book Name Modern Trends In Planning And Designing Of Hospitals Principles & Practice Author Shakti Kumar Gupta, Sunil Kant, Sidhartha S Edition Latest Edition , Title / Book Name Step By Step Hospital Designing And Planning Author Narendra Malhotra Edition Latest Edition , Title / Book Name Hospital Designing And Planning Author Dr D H Sukhwal Edition Latest Edition , Title / Book Name Emergency Department Design: A Practical Guide To Planning For The Future Author Edition Latest Edition , Title / Book Name Hospitals: Facilities, Planning And Management Author G D Kunders Edition Latest Edition , Title / Book Name Planning, Design, And Construction Of Health Care Facilities Author Edition Latest Edition , Title / Book Name Planning, Design, And Construction Of Health Care Facilities Author Edition 4Th , Title / Book Name Hospital Management Text And Cases Author K V Ramanai Edition Latest Edition , Title / Book Name Principles Of Hospital Administration And Planning Author Bm Sakharkar Edition 2Nd , Title / Book Name Healthcare Operations Management Author Daniel B Mc Laughlin, John R. Olson Edition 3Rd , Title / Book Name Management Of Hospitals: A Handbook For Understanding Hospital Services Authorritesth Mishra, Hitesh Mishra Edition Latest Edition , Title / Book Name Hospital And Health Services Administration: Principles & Practice Author Syed Amin Tabish Edition Latest Edition , Title / Book Name Hospital Administration And Management A Comprehensive Guide Author Joydeep Das Gupta Edition 2Nd , Title / Book Name Principles Of Hospital Administration And Planning Author Bm Sakharkar Edition 2Nd , Title / Book Name Hospital Administration Authordc Joshi, Mamta Joshi Edition Latest Edition , Title / Book Name Mcq’S In Management & Hospital Adminstration Author Shakti Kumar Gupta , Sunil Kant Edition Latest Edition , Title / Book Name J&K Csr Author Edition Vol-1 & 2 , Title / Book Name J&K Financial Code Author Edition Latest Edition , Title / Book Name General Financial Rules 2021 Author Edition Latest Edition , Title / Book Name J&K ( Gazetted ) Service Recruitment Rules Author Edition Latest Edition , Psychiatrist , Book Nameself Assessment & Review Of Psychiatry Author Agarwal Edition / Publisher / Year 2Nd2022 , Book Namepsychopharmacology Treatment Of Psychiatric Disorders Author Ananth Edition / Publisher / Year 1St 2007 , Book Namepsychiatry Made Easy Author Anbu Edition / Publisher / Year 1St 2014 , Book Name Psychiatry ( Pocket Tutor ) Author Bajorek Edition / Publisher / Year 2Nd 2018 , Book Name Psychiatry Made Easy ( General & Educational Psychology ) Author Anthikad Edition / Publisher / Year 5Th 2014 , Book Name Approach To Geriatric Neuropsychiatric Problems Author Banerjee Edition / Publisher / Year 1St 2012 , Book Name Social Psychiatry: Principles & Clinical Perspectives Author Chadda Edition / Publisher / Year 1St 2019 , Book Name A Short Textbook Of Psychiatry Author Ahuja Edition / Publisher / Year 7Th 2011 , Book Name Community Mental Health In India Author Chavan Edition / Publisher / Year 1St 2012 , Book Name Behavioural Problems In Children And Adolescents Author Chowdhury Edition / Publisher / Year 1St 2014 , Book Name Bedside Psychiatry ( Indian Psychiatric Society Publication ) Author Chowdhury Edition / Publisher / Year 1St 2019 , Book Name Psychiatric Drug Handbook Author Chowdhury Edition / Publisher / Year 1St2018 , Book Name A Primer Of Research, Publicationand Presentation Author Grover Edition / Publisher / Year 1St2018 , Book Name Forensic Psychiatry: An Indian Sexual Medicine Author Jiloha Edition / Publisher / Year 1St2019 , Book Name Comprehensive Textbook Of Sexual Medicine Author Kar Edition / Publisher / Year 2Nd2014 , Book Name Essentials Of Psychiatry For Obgpractitioners Author Kulkarni Edition / Publisher / Year 1St2015 , Book Name Behavioural Sciences In Medical Practice Author Mehta Edition / Publisher / Year 2Nd 2009 , Book Name Forensic Psychiatry ( Psychiatry And Law ) Author Nambi Edition / Publisher / Year 1St 2013 , Book Name Psychiatry Question Bank For Pg Entrance Exams With Explanatory Ans. Author Raguraman Edition / Publisher / Year 1St2006 , Book Name Drug Therapy For Psychiatric Disorders Author Sagar Edition / Publisher / Year 1St 2020 , Book Name Advancing Frontiers Of Psychiatry Therapeutics Author Singh Edition / Publisher / Year 1St 2020 , Book Name Ips Textbook Of Ug Psychiatry Author Singh Edition / Publisher / Year 1St 2020 , Book Name Culture, Personality And Mental Illness: A Perspective Of Traditional Societies Author Varma Edition / Publisher / Year 1St 2009 , Book Name The Science & Art Of Yoga In Mental & Neurological Healthcare Author S. Varambally Edition / Publisher / Year 1St 2021 , Book Name Advancing Frontiers Of Psychiatry Author Pk Singh Edition / Publisher / Year 1St 2021 , Book Name Ips Textbook Of Undergraduate Psychiatry Author Pk Singh Edition / Publisher / Year 1St2020 , Book Name Social Psychiatry: Principles And Clinical Perspectives Author R. Chadda Edition / Publisher / Year 1St 2019 , Book Name Principles & Practice Of Geriatric Psychiatry, 3E ( Hb ) Author Abou-Saleh Edition / Publisher / Year John Wiley Blackwell 2011 , Book Name Principles & Practice Of Geriatric Psychiatry, 2E ( Hb ) Author Agronin M.E. Edition / Publisher / Year Lippincott 2011 , Book Name Bipolar Psychopharmacotherapy: Caring For The Patient, 2E ( Hb ) Author Akiskal Edition / Publisher / Year John Wiley Blackwell 2011 , Book Name Dyslexia & Mental Health: Investigations From Differing Perspectives ( Hb ) Author Alexander-Passe Edition / Publisher / Yearcbs ( Nova ) 2013 , Book Name Problem-Based Behavioral Science And Psychiatry, 2E ( Hb ) Author Alicata Edition / Publisher / Year Springer 2016 , Book Name Mentalizing In Clinical Practice ( Pb ) Author Allen J.G. Edition / Publisher / Year Apap 2008 , Book Name Trusting In Psychotherapy ( Pb ) Author Allen J.G. Edition / Publisher / Year American Psychiatric Association Publishing 2022 , Book Name Clinical Cases In Psychiatry: Integrating Translational Neuroscience Approaches ( Pb ) Author Altamura Edition / Publisher / Year Springer 2019 , Book Name Dementia, 5E ( Hb ) Author Ames Edition / Publisher / Year Taylor & Francis ( Crc ) 2017 , Book Name Handbook Of Clinical Neurology: Neurobiology Of Psychiatric Disorders ( Hb ) Author Aminoff Edition / Publisher / Year Elsevier Science ( Medical ) 2012 , Book Name Fundamentals Of Clinical Psychopharmacology, 4E ( Pb ) Author Anderson Edition / Publisher / Year Taylor & Francis ( Crc ) 2016 , Book Name Desk Reference To The Diagnostic Criteria From Dsm 5 Spl Edition Author Apa Edition / Publisher / Year Cbs ( App ) 2017 , Book Name Desk Reference To The Diagnostic Criteria From Dsm 5 Tr ( Pb 2022 ) Author Apa Edition / Publisher / Year Apap 2022 , Anatomy , Book Name : Book Of Histological Techniques Author: D R Singh Edition / Publisher: Latest Edition , Book Name : Human Osteology; Latest Edition Author: Nafis Ahmad Faruqi Edition / Publisher Latest Edition , Book Name : Manual Of Human Anatomy Dissection Author: Krishna Garg & Medha Joshi Edition / Publisher Latest Edition , Book Name : Textbook Of Human Embryology; Author Yogesh Sontakke Edition / Publisher 2Nd Edition , Book Name : Textbook Of Human Histology; Author Yogesh Sontakke Edition / Publisher Latest Edition , Book Name : Inderbir Singh’S Textbook Of Anatomy; Author V Subhadra Devi Edition / Publisher 7Th Edition Vol.1 , Book Name : Inderbir Singh’S Textbook Of Anatomy; Author:- V Subhadra Devi Edition / Publisher 7Th Edition Vol.2 , Book Name : Inderbir Singh’S Textbook Of Anatomy; Author:- V Subhadra Devi Edition / Publisher 7Th Edition Vol.3 , Book Name : Abrahams And Mcminns Clinical Atlas Of Human Anatomy, 8E ( Pb ) Author:- Abrahams Edition / Publisher Elsevier Science ( Medical ) , Book Name : Abrahams And Mcminns Clinical Atlas Of Human Anatomy, 8E ( Pb ) ( Ie ) Author:- Abrahams Edition / Publisher Elsevier Science ( Ise & Reprint Medical ) , Book Name Mcminn & Abrahams Clinical Atlas Of Human Anatomy, 7E ( Ie ) ( Pb ) Author:- Abrahams Edition / Publisher Elsevier Science ( Ise & Reprint Medical ) , Book Name Classic Anthology Of Anatomical Charts, 8E, 2 Vols. Set ( Hb ) Author:- Acc Edition / Publisher Lippincott , Book Name Diseases & Disorders: The Worlds Best Anatomical Charts, 4E ( Pb ) Author:- Acc Edition / Publisher Lippincott , Book Name The Musculoskeletal System ( Pb ) Author:- Adds Edition / Publisher Taylor & Francis ( Informa ) , Book Name Anatomy, Physiology And Health Education Author:- Agrawal Edition / Publisher Cbs , Book Name Grants Atlas Of Anatomy, 14E ( Pb ) Author:- Agur Edition / Publisher Lippincott , Book Name Moores Essential Clinical Anatomy, 6E ( Pb ) ( Ie ) Author:- Agur Edition / Publisher Lippincott , Book Name The Hand: Anatomy, Examination, And Diagnosis, 4E ( Pb ) Author:- Akelman Edition / Publisher Lippincott , Book Name Surgical And Radiologic Anatomy For Oral Implantology ( Hb ) Author:- Al-Faraje Edition / Publisher Quintessence Publishing , Book Name Anatomy And Physiology A Lab Manual ( Ie ) Author:- Amitrano R.J Edition / Publisher Cengage , Book Name Atlas Human Anatomy, 3 Vols. Set ( Pb ) Author:- Anastasi Edition / Publisher Edi.Ermes , Book Name Sectional Anatomy By Mri And Ct, 4E ( Hb ) Author:- Anderson Edition / Publisher Elsevier Science ( Medical ) , Book Name The Anatomy & Physiology Learning System, 4E, With Cd ( Pb ) Author:- Applegate Edition / Publisher Elsevier Science ( Medical ) , Book Name Applied Anatomy & Physiology For Manual Therapists ( Pb ) Author:- Archer P Edition / Publisher Lippincott , Book Name Mcminns Color Atlas Of Foot & Ankles Anatomy, 4E ( Hb ) Author:- Logan Edition / Publisher Elsevier Science ( Medical ) , Book Name Mcminns Color Atlas Of Head And Neck Anatomy, 5E ( Hb ) Author:- Logan Edition / Publisher Elsevier Science ( Medical ) , Book Name Mcminns Color Atlas Of Lower Limb Anatomy, 5E ( Hb ) Author:- Logan Edition / Publisher Elsevier Science ( Medical ) , Book Name Workbook And Licensure Exam Prep For Radiography Essentials For Limited Practice, 6E ( Pb ) Author:- Long B.W. Edition / Publisher Elsevier Science ( Medical ) , Book Name Essential Ultrasound Anatomy ( Pb ) Author:- Loukas Edition / Publisher Lippincott , Book Name Grays Anatomy Review, 2E ( Pb ) Author:- Loukas Edition / Publisher Elsevier Science ( Ise & Reprint Medical ) , Pharmacology , Book Name : Lippincott’S Illustrated Review Author:- Sangeeta Sharma Edition / Publisher: Latest Edition , Book Name : Rang & Dale’S Author:- James M Ritter Edition / Publisher: Latest Edition , Book Name : Goodman & Gillman’S Pharmacological Basis Of Therapeutics Author:- Hilal- Dan Dan Edition / Publisher: Latest Edition , Book Name : Katzung And Zerner’S Pharmacology Examination And Board Review Author:- Bertram G. Katzung Edition / Publisher: Latest Edition , Book Name : Sharma & Sharma’S Principles Of Pharmacology Author:- K K Sharma & H L Sharma Edition / Publisher: Latest Edition , Book Name : Essentials Of Medical Pharmacology Author:- K D Tripathi Latest Edition , Book Name : Pharmacology And Pharmacotherapeutics Author:- R S Satoshkar Edition / Publisher: Latest Edition , Book Name : Competency Based Pharmacology Manual For Mbbs Students Author:- Arvind Yadav Edition / Publisher: Latest Edition , Book Name : Applied Pharmacology ( Pb ) Author:- Bardal Edition / Publisher: Elsevier Science ( Medical ) , Book Name : Computational Drug Discovery And Design ( Hb ) Author:- Baron R. Edition / Publisher: Springer , Book Name : Clinical Ocular Pharmacology 5Ed ( Hb ) Author:- Bartlett J.D. Edition / Publisher: Elsevier , Book Name : Essentials Of Pharmacology Author:- Basu Edition / Publisher: Cbs , Book Name : Rapid Clinical Pharmacology: A Student Formulary ( Pb ) Author:- Batchelder Edition / Publisher: John Wiley Blackwell , Book Name : Infectious Disease And Pharmacology Neonatology Questions And Controversies ( Hb 2019 ) Author:- Benitz W E Edition / Publisher: Elevier Science ( Medical ) , Dentistry , Book Name :- Principles Of Oral And Maxiloficial Surgery Author:Peterson’S Edition: Latest Edition , Book Name :- Local Anaesthesia Ad Pain Control Author:Monheims Edition: Latest Edition , Book Name :- Medical Emergencies In Dental Practice Author:Stanly Malamial Edition: Latest Edition , Book Name :- Clinical Periodentology Author:Newzan And Cavranza’S Edition: Latest Edition , Book Name :- Embryology And Aromatics Of The Facial Nerve And Their Surgical Implications Author:Robut Sataloff Edition: Latest Edition , Book Name :- Contemporary Orthodontics Author:William Profit. Edition: Latest Edition , Book Name :- Cohen’S Pathways Of Pulp Author:Cohen Edition: Latest Edition , Book Name :- Dental Emergencies Author:Green Wood Edition: Latest Edition , Surgery , Author:- Smith & Tanagho’S Title : General Urology Publisher: Lange Publications , Author:- Walter Pye’S Title : Surgical Handicrafts Publisher:Franklin Classics Trade Press , Author:- Robert M Zollinger Title : Atals Of Surgical Operations ( Vol.1 To 3 ) Publisher:Mcgraw-Hills , Author:- Charles J Yeo Title : Shackel’S Surgery Of Alimentary Tract ( Vol.1&2 ) Publisher:Elsevier , Author:- Wein Kavoussi & Peter Title : Campbell Wash Wein Urology ( Vol.1 To 3 ) Publisher:Elsevier , Author:- Townsend & Mattox Title : Sabiston Textbook Of Surgery ( 1St South Asian Edition ) Publisher:Elsevier , Author:- Jarnagil & Allen Title : Blumgart’S Surgery Of The Liver, Biliary Duct & Pancreas ( Latest Edition Expected In Jan.2022 ) Publisher:Elsevier , Author:- C.Palanivelu Title : Art Of Laparoscopic Surgery ( 2Nd Edition ) Publisher:Jaypee , Author:- Alfred Cuschieri & George Hanna Title : Essential Surgical Practice Basic Surgical Training Publisher:Crc Press , Author:- S.Das Title : A Concise Textbook Of Surgery Publisher:S.Das , Author:- S.Das Title : A Manual Of Clinical Surgery Publisher:S.Das , Author:- Steaven Corbett, James Gossage & Mathew Vultitude Title : Introduction To Symptoms Of & Sign. Of Surgical Disease. Publisher:Crc Press , Author:- R.M Kirk Title : Basic Surgical Techniques Publisher:Elsevier , Author:- M.L Saha Title : Bedside Clinics In Surgery ( 3Rd Editions ) Publisher:Jaypee , Author:- Mary E Klingen Smith Title : Washington Manual Of Surgery Publisher:Wolter’S Kluwer , Author:- Peter J Morris & William C Wood Title : Textbook Of Surgery Publisher:Oxford , Author:- Srb Title : Manual Of Surgery Publisher:Jaypee , Author:- Srb Title : Clinical Surgery Publisher:Jaypee , Author:- K Rajgopal Shenoy Title : Manual Of Surgery Publisher:Cbs , Author:- Gerard M Doherty Title : Csdt ( 2021 & 2022 ) Publisher:Mcgraw-Hills , Author:- Norman’S Williams Title : Bailey & Love’S Surgery Publisher:Crc Press , Author:- Al-Salem Title : An Illustrated Guide To Pediatric Urology ( Hb ) Publisher:Springer , Author:- Al-Salem Title : Atlas Of Pedaitric Surgery: Principles And Treatment ( Hb ) Publisher:Springer , Author:- Al-Salem Title : Medical And Surgical Complications Of Sickle Cell Anemia ( Hb ) Publisher:Springer , Author:- Al-Salem A.H. Atlas Of Pediatric Surgery Principles And Treatment ( Pb ) Publisher:Springer , Author:- Altomare Title : Nutritional Support After Gastrointestinal Surgery ( Hb ) Publisher:Springer , Author:- Alverdy J. Title : Difficult Decisions In Bariatric Surgery ( Hb ) Publisher:Thieme , Author:- Ames Title : Cervical Spine Deformity Surgery ( Hb ) Publisher:Springer , Author:- Angelos Title : Difficult Decisions In Endocrine Surgery ( Hb ) Publisher:Springer , Author:- Angrisani Title : Bariatric And Metabolic Surgery ( Hb ) Publisher:Springer , Paedia , Author : Goldsmith Title Of Book:Assisted Ventilation Of The Neonate : Evidence - Based Approach To New Born Respiratory Care Edition :Latest Edition , Author : Macdonald Title Of Book:Averys Neonatology Pathophysiology & Management Of The Newborn Edition :Latest Edition , Author : Gleason Title Of Book:Averys Diseases Of The Newborn Edition :Latest Edition , Author : Singh Title Of Book:Care Pof The Newborn Revised Edition :Latest Edition , Author : Gupta Title Of Book:Clinical Methods In Paediatrics Edition :Latest Edition , Author : Lakshmana- Swamy Title Of Book:Clinical Paediatrics Edition :Latest Edition , Author : Eichenwald Title Of Book:Cloherty And Starks Manual Of Neonatal Care Edition :Latest Edition , Author : Benjamin Title Of Book:Echocardiography In Paediatrics And Adult Congenital Heart Disease Edition :Latest Edition , Author : Erickson Title Of Book:Epsteins Inborn Errors Of Development: The Molecular Basis Of Clinical Disorders Of Morphogenisis Edition :Latest Edition , Author : Harris Title Of Book:Examination Paediatrics Edition :Latest Edition , Author : Ajay Sharma Title Of Book:From Birth To Five Years; Childrens Developmental Progress Edition :Latest Edition , Author : Ajay Sharma Title Of Book:From Birth To Five Years; Practical Developmemntal Examination Edition :Latest Edition , Author : Paul Title Of Book:Ghai Essential Pediatrics Edition :Latest Edition , Author : Goel Title Of Book:Hutchisons Atlas Of Pediatric Physical Diagnosis Edition :Latest Edition , Author : Nair Title Of Book:Illingworths Development Of The Infant And The Young Child Edition :Latest Edition , Author : Lissauer Title Of Book:Illiustrated Textbook Of Pediatrics Edition :Latest Edition , Author : More Title Of Book:Infant, Child And Adolescent Nutrition Edition :Latest Edition , Author : Lanzkowsky Title Of Book:Manual Of Pediatrics Hematology And Oncology Edition :Latest Edition , Author : Singh Title Of Book:Medical Emergencies In Children Edition :Latest Edition , Author : Singh Title Of Book:Neslon Essential Of Pediatric Edition :Latest Edition , Author : Kliegmann Title Of Book:Nelsons Textbook Of Pediatrics Edition :Latest Edition , Author : Khilnani Title Of Book:Neonatal And Pediatric Respiratory Diseases Edition :Latest Edition , Author : Beasley Title Of Book:Pediatric Surgical Diagnosis Edition :Latest Edition , Author : Park Title Of Book:Park S Pediatrics Cardiology For Practitioners Edition :Latest Edition , Author : Sperling Title Of Book:Pediatric Endocrinology Edition :Latest Edition , Author : Wyllie Title Of Book:Pediatric Gastrointestinal And Liver Disease Edition :Latest Edition , Author : Ayvner Title Of Book:Pediatric Nephrology Edition :Latest Edition , Author : Richard Polin Title Of Book:Pediatric Secrets Edition :Latest Edition , Author : Siegel Title Of Book:Pediatric Sonography Edition :Latest Edition , Author : Gupta Title Of Book:Pg Textbook Of Pediatrics Edition :Latest Edition , Author : Chheda Title Of Book:Practical Aspects Of Pediatrics Edition :Latest Edition , Author : Long Title Of Book:Principles And Practice Of Pediatric Infectious Diseases Edition :Latest Edition , Author : Bagga Title Of Book:Protocols In Pediatric Nephrology Edition :Latest Edition , Author : Shaffner Title Of Book:Rogers Handbook Of Pediatric Intensive Care Edition :Latest Edition , Author : Swaiman Title Of Book:Swaimans Pediatric Neurology : Princples & Practice Edition :Latest Edition , Author : Agarwal Title Of Book:Textbook Of Pediatrics Edition :Latest Edition , Author : Abraham M Rudolph Title Of Book:Rudolph’S Peditrics Edition :Latest Edition , Author : Frederic N Silverman Title Of Book:Caffey’S Pediatric X-Ray Diagnosis Edition :Latest Edition , Author : Suraj Gupte Title Of Book:Textbook Of Pediatric Emergencies Edition :Latest Edition , Author : Myung K Park Title Of Book:Pediatric Cardiology For Practitioners Edition :Latest Edition , Author : Suraj Gupte, Jaypee Title Of Book:The Short Textbook Of Pediatrics Edition :Latest Edition , Author : N H Menkes Title Of Book:Textbook Of Child Neurology Edition :Latest Edition , Author : 2Nd Edition Title Of Book:Nadas’ Pediatric Cardiology Edition :Latest Edition , Author : David J Field, David Isaacs Title Of Book:Tutorials In Pediatric Differential Diagnosis Edition :Latest Edition , Author : Girish Srivastava Title Of Book:Pediatric Diagnosis Edition :Latest Edition , Author : Title Of Book:Who Children Growth Standards Methods & Development Edition :Latest Edition , Author : Lalitha Krishnan Title Of Book:Practical Neonatal Care Edition :Latest Edition , Author : American Academy Of Pediatrics Title Of Book:Neonatal Resuscitation Textbook Edition :Latest Edition , Author : Lissauer Title Of Book:Illustrated Text Book Of Paediatrics Edition :Latest Edition , Author : B Koletzko Title Of Book:Pediatric Nutrition In Practice Edition :Latest Edition , Author : Naveen Thacker, Nitin K Shah. Title Of Book:Immunization In Clinical Pediatrics Edition :Latest Edition , Author : M Seear Title Of Book:A Manual Of Tropical Pediatrics Edition :Latest Edition , Author : Jerrold H Zar Title Of Book:Biostatistical Analysis Edition :Latest Edition , Author : Balram Choudhary Title Of Book:Paediatrics Lecture Notes Edition :Latest Edition , Title Of Book:Clinical Pediatrics ( History Taking & Case Discussion ) Edition :Latest Edition , Author : M J Robinson, D M Roberton Title Of Book:Practical Pedaitrics Edition :Latest Edition , Author : Thappa Title Of Book:Clinical Pediatric Dermatology Edition :Latest Edition , Title Of Book:Module For Staff Nurse ( Phc / Chc ) Edition :Latest Edition , Author : Robinson / Robertontitle Of Book:Practical Pediatrics Edition :Latest Edition , Author : Shah, Rao, Title Of Book:Iap Specialty Series On Pediatric Endocrinology Edition :Latest Edition , Author : Dr. K P Misra Title Of Book:A Primer Of Ecg Edition :Latest Edition , Author : Piyush Gupta, Navjeevan Singh Title Of Book:How To Write The Thesis & Thesis Protocol, A Primer For Medical, Dental & Nursing Courses Edition :Latest Edition , Author : Dr. Mkc Nair Title Of Book:Adolescent Care 2000 & Beyond Edition :Latest Edition , Author : Ananda Kesavan Title Of Book:Iap Textbook Of Pediatric Radiology Edition :Latest Edition , Author : Sk Kabra, Rakesh L Title Of Book:Essential Pediatric Pulmonoly Edition :Latest Edition , Author : Ghosh, Choudhury Title Of Book:Behavioral Pediatrics Edition :Latest Edition , Author : Lucky Jain, Carlton Title Of Book:Pediatrics Clinics, Advances In Neonatology Edition :Latest Edition , Author : R N Srivastava Title Of Book:Paed. Nephrology Edition :Latest Edition , Author : B Anjaiah Title Of Book:Clinical Pediatric Cardiology Edition :Latest Edition , Author : Kamal Bhasin Title Of Book:Understanding Gender Edition :Latest Edition , Author : Udani, Nanavati Title Of Book:Neonatal Procedures Edition :Latest Edition , Author : Burke A Cunha Title Of Book:Antibiotic Essentials Edition :Latest Edition , Author : Jitender Nagpal, Choudhury, Sachdev Title Of Book:Pediatric Drug Companion Edition :Latest Edition , Author : Meharban Singh, Deorari Title Of Book:Drug Dosages In Children Edition :Latest Edition , Author : Suraj Gupte, Nony Gupte Title Of Book:Pediatric Drug Directoryedition :Latest Edition , Author : Who Title Of Book:Hospital Care For Children Edition :Latest Edition , Author : Valdez, Vallejo Title Of Book:Infectious Diseases In Pediatric Otorinolaryngology Edition :Latest Edition , Author : Naveen Thacker, Nitin K Shah. Title Of Book:Immunization In Clinical Pediatrics Edition :Latest Edition , Author : Micheal R. Trimble Title Of Book:Epilepsy Behavior And Cognitive Function Edition :Latest Edition , Author : Margaret Cameron & Yngve Hofvander Title Of Book:Manual On Feeding Infants And Young Children Edition :Latest Edition , Author : A K Patwari, H P S Sachdev Title Of Book:Frontiers In Social Pediatrics Edition :Latest Edition , Author : Waba & Cefemina Title Of Book:Against All Odds Gendered Challeges To Breastfeeding Edition :Latest Edition , Author : Aap / Acog Title Of Book:Guidelines For Perinatal Care Edition :Latest Edition , Author : Carol K, Taketoma, Title Of Book:Pediatric Dosage Handbook, Edition :Latest Edition , Author : John P Cloherty, Hansen, Stark Title Of Book:Manual Of Neonatal Care Edition :Latest Edition , Author : S Kamath, Bhave, Nair Title Of Book:Guidelines On Management Of Common Pediatric Problems Edition :Latest Edition , Author : Dr. Nalini Shah, Dr. Sudha Title Of Book:Iap Specialty Series On Pediatric Endocrinology Edition :Latest Edition , Author : Title Of Book:Nutritive Value Of Indian Foods Edition :Latest Edition , Author : Title Of Book:Immunization Essentials A Practical Field Guide Edition :Latest Edition , Author : Claudine Amiel Title Of Book:Neurological Development From Birth To Six Years Edition :Latest Edition , Author : Dr. Ira Shah Title Of Book:Management Of Pediatric Hiv Edition :Latest Edition , Author : Dr. Vijay, Dr. Panna, Dr. Naveen Title Of Book:Iap Guide Book On Immunization 2009-11 Edition :Latest Edition , Author : Singh, Shah, Gupta Title Of Book:Principles Of Thesis Writting Edition :Latest Edition , Author : Meherban Singh Title Of Book:Paediatric Clinical Methods Edition: 6Th , Author : Meherban Singh Title Of Book:Care Of The New-Born Edition :Revised 8Th , Author : Meherban Singh Title Of Book:Medical Emergencies In Children Edition: Revised 5Th , Author : A.Parthasarathy Title Of Book:Iap Textbook Of Paediatrics Edition: 7Th , Author : E.P.Garza K.C.James Title Of Book:Fenichel’S Clinical Pediatric Neurology Edition: 8Th South Asia Edition , Author : R.N.Srivastava Arvind Bhagga Title Of Book:Paediatric Nephrology Edition: 6Th , Author : Anoop Verma Pam Kunju Title Of Book:Iap Textbook Of Pediatric Neurology Edition: 2Nd , Author : Richard Martin A.A.Fanaroff Mc Walsh Title Of Book:Neonatal – Perinatal Medicine Edition: 11Th , Author : Kleigman Schor Stanton Title Of Book:Nelson’S Textbook Of Paediatrics - , Author : Cloherty & Stark Title Of Book:Manual Of Neonatal Care Edition: South Asia Edition , Author : M. Glynn William Drake Title Of Book:Hutchinson’S Clinical Methods Edition: 24Th , Author : S. Guandalini Anil Dhawan Title Of Book:Textbookof Paediatric Gastroenterology, Hepatology & Nutrition - , Author : Kleinman M C Daniel M Molley Title Of Book:Harriet Lane Handbook Of Pediatrics Edition: 22Nd , Author : Nathan & Oski Title Of Book:Haematology, Oncologyofinfancy & Childhood Edition: 8Th , Author : Parks Title Of Book:Textbook Of Pediatric Cardiology Edition: South Asia Edition , Author : Parks Title Of Book:Textbook Of Pediatric Cardiology Edition: 6Th , Author : Meherban Singh Title Of Book:Pediatric Clinical Methods Edition: 5Th , Author : Dr Riaz Title Of Book:Peadiatrics Gastroembrology Edition: Latest Edition , Author : Martin Title Of Book:Fanaroff And Martins Neonatal Perinatal Medicine Edition: Latest Edition , Author : Mclntosh Title Of Book:Forfar And Arneil’S Textbook Of Pediatrics Edition: Latest Edition , Author : Florin Title Of Book:Netter’S Pediatrics Edition: Latest Edition , Author : Volpe Title Of Book:Volpe’S Neurology Of The Newborn Edition: Latest Edition , Author : Donald C Fyler Title Of Book:Nadas Pedaitrics Cardiology Edition: Latest Edition , Gynecology And Obst. , Author R.K. Mishra Title Textbook Of Practical Laparoscopic Surgery Publisher Jaypee , Author Ibrahim Alkatout Liselotte Mettler Title Practical Manual For Laparoscopic & Hysteroscopic Gynecological Surgery Publisher Jaypee , Authornutan Jain Title Laparascopic Surgery In Infertility & Gynecology Publisher Jaypee , Authorsadashiv Patil Title Basic Laproscopy & Instrumentation Publisher Jaypee , Author Abbott Title Obstetrics & Gynaecology: An Evidence-Based Guide ( Pb ) Publisher Elsevier Science ( Medical ) , Author Abcarian Title Anal Fistula ( Hb ) Publisher Springer , Authorabramowicz Title First-Trimester Ultrasound ( Hb ) Publisher Springer , Authorabuhamad Title A Practical Guide To Fetal Echocardiography, 3E ( Hb ) Publisher Lippincott , Author Abu-Rustum Title Atlas Of Procedures In Gynecologic Oncology, 3E ( Hb ) Publisher Taylor & Francis ( Crc ) , Author Ades V. Title Sexual And Gender Based Violence A Complete Clinical Guide ( Pb ) Publisher Springer , Author Ainsworth Title Neonatal Formulary: Drug Use In Pregnancy & The First Year Of Life, 7E ( Pb ) Publisher John Wiley Blackwell , Author: Akin Title Atlas Of Gynecologic Oncology Imaging ( Hb ) Publisher Springer , Author Akolekar The Cesarean Birth ( Pb ) Publisher Cbs ( National ) , Authoral Salem M H Title Pediatric Gynecology An Illustrated Guide For Surgeons ( Hb ) Publisher Springer , Author Alcazar Title Ultrasound Assessment In Gynecologic Oncology ( Hb ) Publisher Taylor & Francis ( Crc ) , Author Alcazar Title Ultrasound Of Pelvic Pain In The Non-Pregnant Female ( Pb ) Publisher Taylor & Francis , Author Alkatout Title Hysterectomy: A Comprehensive, 2 Vols. Set ( Hb ) Publisher Springer , Author Allahbadia G.N. Title Textbook Of Assisted Reproduction ( Hb ) Publisher Springer , Author Ambros-Rudolph Title Obstetric & Gynecologic Dermatology, 3E, With Cd ( Hb ) Publisher Elsevier Science ( Medical ) , Authoranger Title The Use Of Robotic Technology In Female Pelvic Floor Reconstruction ( Hb ) Publisher Springer , Author Anthony Sciscione Title Gabbes Obstetrics Study Guide: Normal And Problem Pregnancies ( Pb ) Publisher Elsevier Science ( Medical ) , Author Appelbaum Title Abnormal Female Puberty: A Clinical Casebook ( Pb ) Publisher Springer , Authorapuzzio Title Operative Obstetrics, 4E ( Hb ) Publisher Taylor & Francis ( Crc ) , Author Arafa M. Title Genetics Of Male Infertility A Case Based Guide For Clinicians ( Hb ) Publisher Springer , Author Arnold Title Obstetrics Essentials: A Question-Based Review ( Pb ) Publisher Springer , Authorarora Title Yearbook Of Obstetrics And Gynecology 2018 ( Pb ) Publisher Evangel , Authorartmann Title Stem Cell Engineering: Principles & Applications ( Hb ) Publisher Springer , Author Arulkumaran S. Title Munro Kerrs Operative Obstetrics, 13E ( Pb ) Publisher Elsevier Science ( Ise & Reprint Medical ) , Author Attarian H. Title Sleep Disorders In Women A Guide To Practical Management 3E ( Hb ) Publisher Springer , Author Augustin Title Acute Abdomen During Pregnancy, 2E ( Hb ) Publisher Springer , Author Augustin G. Title Acute Abdomen During Pregnancy ( Pb ) Publisher Springer , Author Avery A. Title Handbook Of Endometrial Pathology ( Hb ) Publisher Medicare Health Science , Author Aziz Title The Diagnosis And Treatment Of Male Infertility A Case Based Guide For Clinicians ( Hb 2017 ) Publisher Springer , Author Babu S. A. Title Clinical Obstetrics And Gynecology History Taking Case Discussion And Practical Viva Voce Topics ( Pb ) Publisher Lippincott , Author Baggish Title Colposcopy Of The Cervix, Vagina, And Vulva Publisher Elsevier Science ( Medical ) , Author Baggish Title Hysteroscopy Visual Perspectives Of Uterine Anatomy, Physiology & Pathology, 3E ( Hb ) Publisher Lippincott , Author Baggish M.S. Title Atlas Of Pelvic Anatomy And Gynecological Surgery, 5E ( Hb ) Publisher Elsevier Science ( Medical ) , Author Bain Title Gynaecology Illustrated, 6E Ie ( Pb ) Publisher Elsevier Science ( Ise & Reprint Medical ) , Author Balen Title Infertility In Practice, 4E ( Spl. Reprint ) ( Original Price: £115.00 ) Publisher Taylor & Francis ( Crc ) , Author Balzarro M. Title Non Neurogenic Bladder Dysfunctions ( Hb ) Publisher Springer , Author Barber M.D. Title Walters And Karram Urogynecology And Reconstructive Pelvic Surgery 5Ed ( Hb ) Publisher Elsevier Science ( Medical ) , Author Barh Title Noninvasive Molecular Markers In Gynecologic Cancers ( Hb ) Publisher Taylor & Francis , Author Barkhusen Title Digital Breast Tomosynthesis ( Hb ) Publisher Thieme , Author Baston H. Title Midwifery Essentials Emergency Maternity Care Vol 6 ( Pb ) Publisher Elsevier Science ( Medical ) , Author Batra Title Colposcopy—Practice And Atlas Publisher Cbs , Author Batra A Title Practical Obstetrics Workbook ( Pb ) Publisher Cbs , Physiology , Books:Clinical Physiology Author : Ashis Banerjee Edition : Latest Edition , Books:Text Book Of Physiology Author : Sheerwood Edition : Latest Edition , Books:Physiology Author : Linda S.Costanzo Edition : Latest Edition , Books:Brs Physiology Author : Linda S. Costanzo Edition : Latest Edition , Books:Medical Physiology Author : Rodney A Rhodes Edition : Latest Edition , Books:Physiology Cases Of Problems Physiology Author : Linda S. Costanzo Edition : Latest Edition , Books:Core Concept In Physiology Author : David R.Bell Edition : Latest Edition , Books:Human Physiology Author : Gillian Pocock Edition : Latest Edition , Books:Human Physiology Author : Stuart Ira Fox Edition : Latest Edition , Mechanism Of Human Physiology Author : Eric P Widmaier Dr Edition : Latest Edition , Books:Guyton And Hall Textbook Of Medical Physiology ( Ie ) 14Ed ( Pb ) Author : Hall J.E. Edition : Elsevier Science ( Medical ) , Books:Guyton And Hall Textbook Of Medical Physiology With Access Code 3Ed ( Sae ) ( Pb ) Author : Hall J.E. Edition : Elsevier Science ( Medical ) , Books:Anatomy, Physiology And Health Education Author : Agrawal Edition : Cbs , Books:Textbook Of Physiology ( Pb ) Author : Ahuja Edition : Cbs , Books:Pathophysiology 7Ed ( Pb ) Author : Banasik J L Edition : Elsevier Science ( Medical ) , Books:Study Guide For Pathophysiology 7Ed ( Pb ) Author : Banasik J L Edition : Elsevier Science ( Medical ) , Books:Ganongs Review Of Medical Physiology, 26E ( Pb ) Author : Barrett K.E. Edition : Mcgraw Hill , Books:Cases & Problems Physiology, 4E ( Pb ) Author : Costanzo Edition : Lippincott , Books:Brs Physiology, 7E ( Pb ) Author : Costanzo L. Edition : Lippincott , Books:Costanzo Physiology 7Ed ( Pb ) Author : Costanzo L.S. Edition : Elsevier Science ( Medical ) , Books:Boron And Boulpaep Concise Medical Physiology ( Pb ) Author : Boron W. F. Edition : Elsevier Science ( Medical ) , Books:C C Chatterjees Human Physiology 14Ed Vol 1 ( Pb ) Author : Chatterjee Cc Edition : Cbs , Books:C C Chatterjees Human Physiology 14Ed Vol 2 ( Pb ) Author : Chatterjee Cc Edition : Cbs , Books:Cc Chatterjees Manual Of Practical Physiology ( Pb ) Author : John Edition : Cbs , Books:Cc Chatterjees Manual Of Practical Physiology ( Pb ) Author : John Edition : Cbs , Books:Medical Physiology Author : G.K Pal Edition : Ahuja ( Latest Edition ) , Books:Textbook Of Medical Physiology With Access Code 3Ed ( Pb ) Author : Khurana I. Edition : Elsevier Science ( Ise & Reprint Medical ) , Biochmistry , Author Ferrier Name Of Book Lippincotts Illustrated Reviews Biochemistry Volume Latest Edition 7 / Ed Publisher Lww , Author Satyanarayana Biochemistry Volume Latest Edition 5Ed Publisher R.E , Author By Indumati V , Sowbhagya Lakshmi Name Of Book Integrated Textbook Of Biochemistry Volume Latest Edition Latest Publisher Paras Medical Publisher , Author Dr. Showkat Bhat, Dr. Sabhaya Majid, Dr. Amarjeet S.Bhatia, Dr. Mohinder Name Of Book Lab Technology Manual Volume Latest Edition Latest Publisher Ahuja Publishers House , Author Praful Godkar Name Of Book Text Book 0F Medical Laboratory Technology Volume Latest Edition 1 / Ed Publisher Bhalani Publishing House , Author Ramamoorthy P Name Of Book Textbook Of Biochemistry For Paramedical Students Volume Latest Edition Latest Publisher Jaypee Brothers Medical Publishers , Author Dm Vasudevan Name Of Book Concise Textbook Of Biochemistry For Paramedical Students Volume Latest Edition Second Edition Publisher Jaypee Brothers Medical Publishers , Author Poonam Agrawal Name Of Book Practical Biochemistry With Clinical Correlation Volume Latest Edition Latest Publisher Cbs Publisher And Distributers , Author Poonam Agrawal Niket Verma Name Of Book Competency Based Log Book In Biochemistry Volume Latest Edition Latest Publisher Cbs Publisher And Distributers , Author Neeru Bhaskar Priyanka Tangri Name Of Book Log Book In Biochemistry Volume Latest Edition Latest Publisher Cbs Publisher And Distributers , Author Poonam Agrawal Name Of Book Clinical Case Discussion In Biochemistry Volume Latest Edition Latest Publisher Cbs Publisher And Distributers , Author Niket Verma Poonam Agrawal Name Of Book Competency Based Log Book In Aetcom Medical Humanities, Sports And Extra Curricular Activities Volume Latest Edition Latest Publisher Cbs Publisher And Distributers , Author Taylor D. Name Of Book Laboratory Manual For Practical Biochemistry ( Hb ) Volume Latest Edition Latest Publisher John Wiley ( Original ) , Author Torrence Name Of Book Biomedical Chemistry: Applying Chemical Principles To The Understanding And Treatment Of Disease ( Hb ) Volume Latest Edition Latest Publisher Cbs , Author Varley / Harold Name Of Book Practical Clinical Biochemistry, 4E Volume Latest Edition Latest Publisher Cbs , Author Varley / Harold Name Of Book Practical Clinical Biochemistry, 6E Volume Latest Edition Latest Publisher John Wiley ( Wie ) , Author Voet Name Of Book Biochemistry, 4E ( Pb ) Volume Latest Edition Latest Publisher John Wiley ( Wie ) , Author Voet Name Of Book Principles Of Biochemistry, 4E Ise ( Pb ) Volume Latest Edition Latest Publisher John Wiley ( Original ) , Author Voet Name Of Book Voets Principles Of Biochemistry, 5E ( Global Edition ) ( Pb ) Volume Latest Edition Latest Publisher John Wiley ( Wse & Exclusive Indian Spl. Price Titles ) , Author Voet D. Name Of Book Voets Biochemistry Adapted Edition 2021 ( Pb ) Volume Latest Edition Latest Publisher John Wiley ( Wse & Exclusive Indian Spl. Price Titles ) , Forensic Medicine & Toxicology , Title Review Of Forensic Medicine & Toxicology ( Latest Edition ) Authors Gautum Biswas Publisher Jaypee Brothers Publications New Delhi , Title Recent Advances In Forensic Medicine & Toxicology ( Latest Edition ) Authors Gautum Biswas Publisher Jaypee Brothers Publications New Delhi , Title Modern Medical Toxicology ( Latest Edition ) Authors V.V Pillory Publisher Jaypee Brothers Publications New Delhi , Title Principles Of Forensic Medicine Including Toxicology ( Latest Edition ) Authors Apoorva Nandi Publisher New Central Book Agency Pvt. Ltd. , Title Text Book Of Forensic Medicine & Toxicology ( Principles & Practice ) New Editionauthors Krishan Vij Publisher Elsevier Publishing Company , Title Text Book Of Forensic Medicine & Toxicology ( Latest Edition ) Authors P.C. Dikshit Publisher Peepee Publishers And Distributors ( P ) Ltd , Title A Colour Atlas Of Medico Legal Postmortem & Forensic Pathology ( ( Latest Edition ) 1. Authors C.K. Parikh 2. Authors Cotton & Cross Publisher Daystor Publications , Title Postmortem Procedures ( Latest Edition ) Authors G.A.Gresham & A.F.Turner; Tedeschi Eckert Tedeschi 1 Publisher. Wolfe Medical Publications. 2. Publisher W.B. Saunders Co. Philadelphia England , Title Code Of Criminal Procedures ( Latest Edition ) Authors B. Malik Publisher Delhi Law House , Title Legal Medicine ( Latest Indian Edition ) Authors Gradwow’S Publisher K.M. Verghese Company , Title A Colour Atlas Of Burn’S Injuries ( Latest Edition ) Authors Clarlee Publisher Daystar Publications , Title Forensic Pathology ( Latest Edition ) Authors Polinak Publisher Kamla Raj Enterprises Delhi , Title Forensic Medicine ( Latest Edition ) Volume 1, 2, 3 Authors Tedeschi Eckerttedeschi Publisher W.B. Saunders Co. Philadelphia England , Title Forensic Dna Evidence Interpretation ( Latest Edition ) Authors Buckleton Publisher Malhotra House Mumbai , Title Forensic Recovery Of Human Remains ( Latest Edition ) Authors Dupras Publisher Crc Press , Title Modern Legal Medicine Psychiatry & Forensic Sciences ( Latest Edition ) Authors William J. Curran, Louis Mcgarry, Charles S. Petty Publisher F.A. Dakis Company Philadelphia , Title The Essential Of Forensic Medicine & Toxicology ( Latest Edition ) Authors K.S. Narayan Reddy Publisher Jaypee Brothers Medical Publishers , Title Principle Of Forensic Medicine & Toxicology ( Latest Edition ) Authors Rajesh Bardale Publisher Jaypee Brothers Medical Publishers , Title Parikhs Book Of Medical Jurisprudence Of Forensic Medicine & Toxicology ( Latest Edition ) Authors C.K. Parikh Publisher Cbs Publishers & Distributors , Title Text Book Of Forensic Medicine & Toxicology ( Latest Edition ) Authors Nageshkumar G Rao Publisher Jaypee Brothers Medical Publishers , Title Practical Aspects Of Forensic Medicine ( Latest Edition ) Authors Nageshkumar G Rao Publisher Jaypee Brothers Medical Publishers , Title Practical Aspects Of Forensic Medicine ( Latest Edition ) Authors Rk Gorea ; Td Dogra ; A.D. Aggarwal Publisher Jaypee Brothers Medical Publishers , Title Medico Legal Aspects Of Sexual Offences ( Latest Edition ) Authors Kumar Publisher Daystar Publications , Title Medical Jurisprudence & Toxicology Revised By Franklin & Others ( Latest Edition ) Authors Modi Publisher Daystar Publications , Title The Essentials Of Forensic Medicine & Toxicology With Colour Atlas ( Latest Edition ) Authors Selim Reza Publisher Essence Publications , Title Textbook Of Forensic Odontology ( Latest Edition ) Authors Promod Dayal Publisher Paras Medical Publisher , Title Lyon’S Medical Jurisprudence & Toxicology ( Latest Edition ) Authors Dr. Td Dogra Publisher Delhi Law House , Title Medical Toxicology ( Latest Edition ) Authors Richard C. Dart Publisher Lippincott Williams & Wilkin , Title Forensic Neuropathology ( Latest Edition ) Authors Jan E. Leestma Publisher Crc Press , Title Goldfranks Toxicologic Emergencies ( Latest Edition ) Authors Lewis Authors R. Goldfrank Publisher Mc Graw Hill Education / Exclusively Distd. By Jaypee , Title Principles Of Forensic Medicine And Toxicology ( Latest Edition ) Authors Bardale Rajesh Publisher Jaypee Brothers Medical Publishers , Title Forensic Psychiatry And Psychology ( Latest Edition ) Authors William J. Curran Publisher F.A. Davis Company , Title Criminal Investigation Techniques ( Latest Edition ) Authors Donald O. Schultz Publisher Gulf Publishing Co , Title Brogdon’S Forensic Radiology Authors Michael J. Thali M.D. ( Editor ) , Mark D. Viner ( Editor ) , B.G. Brogdon ( Editor ) Publisher Crc Press , Title Brogdons Forensic Radiology, Second Edition Authors Michael J. Thali, M.D., Mark D. Viner, B.G. Brogdon Publisher Taylor & Francis , Title Principles Of Forensic Medicine Including Toxicology ( Latest Edition ) Authors Apurba Nandy Publisher New Central Book Agency , Title Modern Medical Toxicology ( Latest Edition ) Authors V.V. Pillay Publisher Jaypee Brothers Medical Publishers , Title Text Book Of Forensic Medicine & Toxicology ( Latest Edition ) Authors P.C.Dikshit Publisher Peepee Publishers And Distributors ( P ) Ltd; , Title A Colour Atlas Of Medico Legal Postmortem & Forensic Pathology ( Latest Edition ) Authors C.K Parikh Publisher Daystar Publication , Title Oxford Medical Dictionary , Title Recent Advances Forensic Medicine & Toxicology Authors Gautam Biswas Publisher Jaypeebrothers, Medical Publishers Pvt. Limited, , Title Essentials Of Forensic Medicine & Toxicology Authors K.S. Narayan Reddy Publisher Jaypee Brothers Medical Publishers , Title Forensic Dna Evidence Interpretation Authors Buckleton Publisher Malhotra House Mumbai , Title Forensic Pathology Authors David Dolinak Publisher Academic Press , Title Modern Legal Medicine Psychiatry & Forensic Science Authors Curran, William J. & Mcgarry, A. Louis & Petty, Charles S. Publisher F.A. Davis Company , Title Principles Of Forensic Medicine And Toxicology Authors Rajesh Bardale Publisher Jaypee Brother , Title Practical Forensic Medicine ( Practical Manual ) Authors Dr. Soadiya Saeed Publisher Universal Book House. , Title Review Of Forensic Medicine Authors Dr. Sumit Seth Publisher Peepee Publishers And Distributors Pvt , Title Forensic Medicine A Guide To Principles Authors I.Gardon H.A.Shapiro Publisher Churchill Livingstone, Edinburgh , Title A Short Book Of Forensic Medicine Authors A. Ramachandran M.R Chandran Publisher All India Publisher & Distributor , Title Forensic Pathology Authors Dominick Dimaio Publisher Crc Press , Title Simpson’S Forensic Medicine ( Latest Edition ) Authors Richard Shepherd Publisher Hodder Arnold , Title Clinical Forensic Medicine Authors W. D. S. Mclay Publisher Greenwich Medical Media; , Title Emergency Toxicology Authors S. K. Gupta Publisher Narosa; , Title Oxford Handbook Of Forensic Medicine Authors Jonathan P. Wyatt, Tim Squires , Guy Norfolk , Jason Publisher Oup Uk; Illustrated Edition , Title Forensic Medicine Authors Reinhard B. Dettmeyer , Marcel A. Verhoff , Harald F. Schütz Publisher Springer Nature , Title Colour Atlas Of Forensic Medicine Authors D Govindiah Publisher Jaypee Brothers Medical Publishers; , Title Handbook Of Forensic Medicine & Toxicology Authorsvv Pillay , Title Handbook Of Forensic Medicine & Toxicology Authors Basu , Title Manual Of Forensic Medicine Authors Mestri Publisher Jaypee Brothers Medical Publishers , Title Practical Rape Investigation Authors Robert R. Hazelwood Publisher Crc Press , Title Viva In Forensic Medicine & Toxicology Authors Lc Gupta, Nk Modi Publisher Jaypee Brothers Medical Publishers , Title Viva In Forensic Medicine & Toxicology Authors Jp Saxena Publisher Jaypee Brothers Medical Publishers ( P ) Ltd , Title Hand Book Of Forensic Pathology Authors Di Maio , Title The Short Text Book Of Forensic Medicine & Toxicology Authors Ramchandram , Title Legal Aspects Of Patient Care Authors R.K Sharma , Title The Essentials Forensic Medicine & Toxicology Authors Reddy , Title Comprehensive Medical Toxicology Authors Pillay , Title Handbook Of Forensic Medicine & Toxicology Authors P.V. Chadha , Title Toxicology Secrets Authors Hanley & Belfus , Title Investigative Forensic Hypnosis Authors Jeo Nichaus , Title Clinical Forensic Medicine Authors W D S Mclay , Title Self Assessment In Forensic Medicine & Toxicology Authors V.V. Pillay , Title Guide To Forensic Pathology Authors Jay Dix , Emergency Toxicology Authors S.K.Gupta , Title Forensic Radiology Authors D. Govindiah , Title Law & The Doctor Authors Sunila Sharma , Title Review Of Forensic Medicine Authors Sumit Seth , Title Forensic Medicine Authors Guharaj , Title The Synopsis Of Forensic Medicine & Toxicology Authors K.N.S Reddy , Title A Text Book Of Modern Toxicology Authors Hodgson & Levi , Title Essentials Of Toxicology Authors Klaassen & Watkins , Title A Text Book Of Forensic Medicine & Toxicology Authors Pillay , Title A Text Book Of Forensic Medicine & Toxicology Authors Krishan Vij , Title Lyon’S Medical Jurisprudence & Toxicology Authors T.D.Dogra , Title Digest Of Medical Jurisprudence & Toxicology Authors Mishra &Awasthi , Title Oxford Dictionary English To English , Title Oxford Dictionary English To Hindi , Title Oxford Dictionary English To Urdu , Medicine , Title 100 Cases In Emergency Medicine And Critical Care ( Excl. Abc ) Edition Latest Edition Author Shamil Publisher Crc , Title 100 Cases In General Practice, 2Ed ( Excl. Abc ) Edition Latest Edition Author Step Henson Publisher Ctc , Title 100 Diagnostic Dilemmas In Clinical Medicine ( Excel Abc ) Edition Latest Edition Author Layne Publisher Crc , Title 1000 Questions And Answers From Clinical Medicine 1000 Questions And Answers From Kumar & Clarks Clinical Medicine, 2E Edition Latest Edition Author Kumar Publisher Elsiver , Title 1000 Questions And Answers From Clinical Medcine Edition Latest Edition Author Kumar Publisher Elsiver , Title 250 Cases In Clinical Medicine, International Edition, 4E Edition Latest Edition Author Baliga Publisher Elsiver , Title 258 Clinical Cases In Medicine: For Md , Dnb And Mrcp Examinations ( Pb ) Edition Latest Edition Author Chugh Publisher Cbs , Title A Short History Of Medicine ( Short Histories ) Edition Latest Edition Author Steve Parker Publisher Dk , Title Acute Medicine: Uncommon Problems And Challenges Edition Latest Edition Author Cade Publisher Cambridge , Title Advance Research In Medicine Edition Latest Edition Author Anthony Clive Publisher Foster , Title Andreoli And Carpenter’S Cecil Essentials Of Medicine, International Edition Latest Edition Author Benjamin Publisher Elsiver , Title Annual Review Of Medicine Edition Latest Edition Author Caskey Publisher Na , Title Atlas Of Clinical Emergency Medicine Edition Latest Edition Author Sherman Publisher Lww , Title Atlas If Internal Medicine, 3E ( Hb ) Edition Latest Edition Author Braunwalid Publisher Springer , Title Atult Emergency Medicine At A Glance ( Pb ) Edition Latest Edition Author Huges Publisher Wiley , Title Avoiding Common Prehospital Errors Edition Latest Edition Author Lawner Publisher Lww , Title Avoiding Errors In Adult Medicine Edition Latest Edition Author Reckless Publisher Wiley , Title Basic Science Methods For Clinical Researchers, 1 / Ed Edition Latest Edition Author Jalali Publisher Ap , Title Beats Guide To Physical Examination Edition Latest Edition Author Bickley Publisher W.K. , Title Bedside Clinics In Medicine ( * ) Edition Latest Edition Author Nischal Publisher W.K. , Title Bedside Clinics In Medicine, 8 / Ed Part-I Edition Latest Edition Author Udwadia Publisher Oxford , Title Black’S Medical Dictionary 42Ed Edition Latest Edition Author Kundu Publisher Ksp , Title Brenner And Rector’S The Kidney, 2-Volume Set, 11E Edition Latest Edition Author Marcovitchpublisher Bloomsbury Pub , Title Care Bundles In Emergency Medicine Edition Latest Edition Author Shorecki Publisher Elsiver , Title Case Study In Internal Medicine Edition Latest Edition Author Williamson Publisher Elsiver , Title Chronic Disease Management ( Excel. Abc ) Edition Latest Edition Author Gauthier / Ros A-Neto Publisher Radcliffe , Title Case Study In Emergency Medicine Edition Latest Edition Author Na Publisher Cambridge , Title Case Study In Internal Medicine Edition Latest Edition Author Kakar Publisher Jaypee , Title Churchill’S Pocket Books Of General Practice, 3E Edition Latest Edition Author Mcevoy Publisher Radcliffe , Title Clinical Translational Science; Principles Of Human Research Edition Latest Edition Author Cartwright Publisher Elsiver , Title Clinical Examination Essentials; An Introduction To Clinical Skills ( And ) Edition Latest Edition Author Talley Publisher Elsiver , Title Clinical Examination, 8E ( South Asia Edition ) Edition Latest Edition Author Talley Publisher Re , Title Clinical Methods In Medicine: Clinical Skillsand Practice, 2 / Ed Edition Latest Edition Author Chugh J Publisher Aypee , Title Clinical Naturopathic Medicine Edition Latest Edition Author Hechtman Publisher Elsiver , Title Clinical Practice ( Experience And Evidence Based Approach ) ( * ) Edition Latest Edition Author Maitra Publisher Ncba , Title Clinical Procedures For Medical Assistants Edition Latest Edition Author Bonewit West Publisher Elsiver , Title Clinical Review: General Medicine, Haematology And Rheumatology Edition Latest Edition Author Chritian Fraser Publisher Foster , Title Communicate Care Cure-3 / Ed Edition Latest Edition Author Thomas Publisher Wk , Title Complementary And Alternative Medicine: Evidence Base Approach Edition Latest Edition Author Brendon Goule Publisher Callisto , Title Comprehensive Care For Complex Patients Edition Latest Edition Author Fnaken Publisher Cambridge , Title Consent To Treatment Edition Latest Edition Author Lynch Publisher Radcliffe , Title Current Diagnosis & Treatment Emergency Medicine 8 / Ed ( Ie ) ( Pb ) Edition Latest Edition Author Stone Publisher Mgh , Title Data Interpretation Made Easy For Medical Students And Junior Doctors Edition Latest Edition Author Sharma Publisher Radcliffe , Title Davidson’S Principles And Practice Of Medicine, International Edition, 23E Edition Latest Edition Author Ralston Publisher Re , Title Diagnosis In Acute Medicine ( Pb ) Edition Latest Edition Author Gonen Publisher T&F , Title Diagnosis Treatment Poisoning Drug Overdose Made Easy Edition Latest Edition Author Dev Rajan Publisher Jaypee , Title Differential Diagnosis In Clinical Medicine Edition Latest Edition Author Din Dayalan Publisher Jaypee , Title Essay Voyage In Medicine Edition Latest Edition Author Natrajan Publisher Ahuja , Title Emergency Care And Transportation Of The Sick And Injured: Aaos, 9 / Ed Edition Latest Edition Author Na Publisher Jbi , Title Emergency Department Leadership And Management Edition Latest Edition Author Kay Den Publisher Cambridge , Title Emergency Medicine Edition Latest Edition Author Abby Cussasck Publisher Calisto , Title Emergency Medicine And Critical Care Edition Latest Edition Author Abby Cusack Publisher Hayle , Title Emergency Medicine Simulation Workbook-A Tool For Boards ( Expert Consultation ) Edition Latest Edition Author Thoureen Publisher Willey , Title Endocrinology In Clinical Practice 2 / Ed Edition Latest Edition Author Harris Publisher Crc , Title Essential Clinical Medicine: Symptoms, Diagnosis, Management, ( Pb ) ( Excl. Abc ) Edition Latest Edition Author Gibson Publisher Cambridge , Title Essential Evidence Based Medicine With Cd Rom Edition Latest Edition Author Dan Mayel Publisher Cup , Title Essential Notes In Prescribing For Final And Junior Doctors Edition Latest Edition Author Mandalia Publisher Crc , Title Essential Of Human Disease And Conditions – Text And Workbook Edition Latest Edition Author Frazier Publisher Elsiver , Title Essentials Of Internal Medicine Edition Latest Edition Author Anthony Parcels Publisher Foster , Title Essentials Of Internal Medicine, 4 / Ed Edition Latest Edition Author Ray Publisher Jaypee , Title Essentials Of Kumar And Clark’S Clinical Medicine, International Edition Latest Edition Author Zammit Publisher Elsiver , Title Ethical Dilemmas In Emergency Medicine Edition Latest Edition Author Marco Publisher Cambridge , Title Evidence Based Diagnosis Edition Latest Edition Author Kohn Publisher Cambridge , Title Evidence Based Medicine Edition Latest Edition Author Gil Merrill Publisher Foster , Title Evidence Based Physical Diagnosis, 4E Edition Latest Edition Author Mcgee Publisher Elsiver , Title First Aid, Cpr, And Aed Essentials 6 / Ed Edition Latest Edition Author Aaos Publisher Jbi , Title Fluids, Electrolytes And Acid-Based Balance 1St / 2014 Edition Latest Edition Author Kumar Publisher Paras , Title Geriatric Emergency Medicine Edition Latest Edition Author Kahn Publisher Cambridge , Title Global Views On Emergency Medicine Edition Latest Edition Author Abby Cusak Publisher Foster , Title Hand Book Of Clinical Specialities Edition Latest Edition Author Cornor Langdon Publisher Foster , Title Harrison’S Principle Of Internal Medicine, 20 / Ed, 2-Vols Edition Latest Edition Author Jameson Publisher Mgh , Title Haemophilia: Genes And Diseases Edition Latest Edition Author Jenkins Publisher Foster , Title Human Interests Of Ethics For Physicalists Edition Latest Edition Author Mendola Publisher Oxford , Title Hutchinson’S Clinical Methods: An Integrated Approach To Clinical Edition Latest Edition Author Glynn Publisher Elsiver , Title Hyperlipidaemia Diagnosis And Management, 3 / E ( Excl. Abc ) Edition Latest Edition Author Durrington Publisher Hodder , Title Implementing Precision Medicine In Best Practices Of Chronic Airway Edition Latest Edition Author Agache Publisher Ap , Title Initial Management Of Acute Medical Patients, 2Ed. 2012 Edition Latest Edition Author Garner Publisher Willey , Title Integrated Management Of Depression In The Elderly, ( Excl Abc ) Edition Latest Edition Author Chew-Graham Publisher Cambridge , Title Kumar & Clark’S Cases In Clinical Medicine, 3E Edition Latest Edition Author Kumar Publisher Elsiver , Title Living With A Long Term Illness The Facts Edition Latest Edition Author Campling Publisher Oxford , Title Long Cases In Clinical Medicine Edition Latest Edition Author Sparker Publisher Re , Title Madcleods Clinical Diagnosis, International Edition Edition Latest Edition Author Japp Publisher Elsiver , Title Macleod’S Clinical Examination: With Student Consult Online Access, Edition Latest Edition Author Innes Publisher Elsiver , Title Macleod’S Clinical Osces, 1E Edition Latest Edition Author O’Neill Publisher Curchill , Title Managing Myeloproliferative Neoplasms Edition Latest Edition Author Edited By Ruben A. Mesa Publisher Cup , Title Manual Of Practical Medicine, 6 / Ed Edition Latest Edition Author Alagappan R Publisher Jaypee , Title Manual Of Doctor And Law Edition Latest Edition Author Goel Publisher Jaypee , Title Mayo Clinic Internal Medicine Board Review, 11 / Ed Edition Latest Edition Author Wittich Publisher Oxford , Title Mayo Clinical Medical Manual ( Volume 2 ) Edition Latest Edition Author Na Publisher Informal Health Care , Title Medication Safety: An Essential Guide, ( Excel Abc ) Edition Latest Edition Author Courtenay Publisher Cambridge , Title Mitochondrial Medicine: Mitochondrial Metabolism, Disease Edition Latest Edition Author Gvozdjakova Publisher Springer , Title Neurohospitalist Medicineedition Latest Edition Author Josephson, Freeman Publisher Cambridge , Title New Frontiers In Geriatric Medicine Edition Latest Edition Author Roger Simpson Publisher Hayle , Title New Principle Of Best Practice In Clinical Audit 2 / Ed Edition Latest Edition Author Burgess Publisher Crc , Title Oxford Concise Medical Dictionary, 9Ed Edition Latest Edition Author Martin Elizabeth Publisher Oxford , Title Oxford Handbook Of Clinical Medicine 10 / Ed Edition Latest Edition Author Wilkinson Publisher Oxford , Title Oxford Handbook Fo Clinical Specialities 10Ed ( Pb 2016 ) Edition Latest Edition Author Baldwin Publisher Oxford , Title Oxford Handbook Of Complementary Medicine, ( Excel, Abc ) Edition Latest Edition Author Ernst Publisher Oxford , Title Oxford Handbook Of Emergency Medicine Edition Latest Edition Author Wyatt Publisher Oxford , Title Oxford Handbook Of Key Clinical Evidence Edition Latest Edition Author Harrison Publisher Oxford , Title Oxford Handbook Of Clinical Nephrology 4 / Ed 3 Vols. ( Ub ) ( Abc. Excl ) Edition Latest Edition Author Turner Publisher Oxford , Title Pas Mrcp Part2: A Problem-Based Approach Edition Latest Edition Author Hamilton Publisher Theime , Title Persuasion In Clinical Practice Edition Latest Edition Author Walker Publisher Radcliffe , Title Physical Signs Symptoms Diagnosis And Differentials Diagnosis In Clinical Edition Latest Edition Author Chugh Publisher Ap , Title Practical Management And Leadership For Doctors Edition Latest Edition Author Wattis Publisher Radcliffe , Title Practical Professionalism In Medicine: A Global-Case Based Workbook Edition Latest Edition Author Worthington Publisher Radcliffe , Title Prescribing In Diabetes Edition Latest Edition Author Hill Publisher Cambridge , Title Sepsis: Clinical Diagnosis And Treatment Edition Latest Edition Author Scarlett Beckinsale Publisher Hayle , Title Sherlock’S Diseases Of The Liver And Biliary System, 13 / Ed Edition Latest Edition Author Dooley Publisher Wiley , Title Substance Abuse Disorders – Evidence And Experience Edition Latest Edition Author Ghodse Publisher Wiley , Title Textbook Of Medicolegal Issues Edition Latest Edition Author Tiwari Publisher Jaypee , Title Textbook Of Palliative Medicine Edition Latest Edition Author Bruera Publisher Hodder , Title The Practical Pocket History Taking And Clinical Examination ( Excl Abc ) Edition Latest Edition Author Williamson Publisher Radcliffe , Title The Toxicologist’S Pocket Handbook ( Excl Abc ) Edition Latest Edition Author Derelanko Publisher Crc , Title The Washington Manual General Internal Medicine Subspecialty Edition Latest Edition Author Wash. Univ. Publisher Wk , Title The Washington Manual Of Emergency Medicine Edition Latest Edition Author Levine Publisher Wk , Title Tintinalli’S Emergency Medicine Manual 7Th Edition Edition Latest Edition Author Cline Md Publisher Tmh , Title Venus Access Made Easy ( Excl Abc ) Edition Latest Edition Author Forsyth Publisher Crc , Title Venous Thromboembolism In Afdvance Disease : A Clinical Guide Edition Latest Edition Author Na Publisher Oxford , Title Writing In English For The Medical Science: A Practical Guide, ( Excl Abc ) Edition Latest Edition Author Hart Publisher Crc , Title Harrison’S Principles Of Internal Medicine Edition Latest Edition Author Publisher , Title Davidsons Principle And Practice Of Medicine Edition Ralston Author 23Rd Publisher Elsevier , Title Davidsons Principle And Practice Of Medicine Edition Ralston Author 23Rd Publisher Elsevier , Title Davidsons Principle And Practice Of Medicine Edition Ralston Author 23Rd Publisher Elsevier , Title Clinical Ecg Edition C.Chicot.J.Vas Author -- Publisher Ane, Book, Delhi , Title P.J.Mehta’S Practical Medicine Edition Nihar.P.Mehta Author 21St Publisher Shicpa Mehta, Mumbai , Title P.J.Mehta’S Practical Medicine Edition Nihar.P.Mehta Author 21St Publisher Shicpa Mehta, Mumbai , Title The Washington Manual Of Medical Thherapeutics Edition Pavan.Bhatt Author 35Th Publisher Lippincot. , Title The Washington Manual Of Medical Thherapeutics Edition Pavan.Bhatt Author 35Th Publisher Lippincot , Title Pediatrics Neurology Edition Gregory.L.Holmes Author 2Nd Publisher Oxford.Uk. , Title Pediatrics Neurology Edition Holmes Author 2Nd Publisher Oxford.Uk. , Title Pediatrics Neurology Edition Holmes Author 2Nd Publisher Oxford.Uk. , Title Golwalla’S Medicine For Students Edition Aspi.F.Golwalla Author 25Th Publisher Jaypee .New Delhi , Title Golwalla’S Medicine For Students Edition Aspi.F.Golwalla Author 25Thpublisher Jaypee .New Delhi , Title Golwalla’S Medicine For Students Edition Aspi.F.Golwalla Author 25Th Publisher Jaypee .Newdelhi , Title Medicine Prep. Manual For Undergraduate Edition Mathew And Agarwal Author 5Th Publisher Relx.India , Title Medicine Prep. Manual For Undergraduate Edition Mathew And Agarwal Author 5Th Publisher Relx.India , Title Integrated Medical And Surgical Gastroenterology Edition Van.Lanshot Author 1St Publisher Thieme.N.Y , Title Integrated Medical And Surgical Gastroenterology Edition Van.Lanshot Author 1St Publisher Thieme.N.Y , Title Integrated Medical And Surgical Gastroenterology Edition Van.Lanshot Author 1St Publisher Thieme.N.Y , Title Sherlock Diseases Of The Liver And Birlaly System Edition James.S.Dooley Author 13Th Publisher Willey.U.K. , Title Leoschamroth And Introduction Of Elecro Cardiography Edition Narasimahan Author 8Th Publisher Willey.U.K , Title Clinicans Guide O Lipid And Coronary And Hurt Diseases Edition D.J.Betteridge Author 2Nd Publisher Britain , Title Clinicans Guide O Lipid And Coronary And Hurt Diseases Edition D.J.Betteridge Author 2Nd Publisher Britain , Title Api Textbook Of Medicine Edition Y.P.Munjal Author 10Th Publisher Jaypee New Delhi , Title Api Textbook Of Medicine Edition Y.P.Munjal Author 10Th Publisher Jaypee New Delhi , Title Brain Diseases Of T He Nervous System Edition Michael Donaghy Author 12Th Publisher Oxford.U.K , Title Oxford Desk Reference Respiratory Medicine Edition Nick Maskell Author -- Publisher Oxford , Title Breast Cancer Early Detection With Mammography Edition Laszlo Tabar Author 1St Publisher Thieme Germany , Title Breast Cancer Early Detection With Mammography Edition Laszlo Tabar Author 1St Publisher Thieme Germany , Title Braunwalds Heart Disease Edition Zipes Douglasauthor 11Th Publisher Elsevier India , Title Hutchisons Clinical Methods Edition Michael Glyn Author 24Th Ed Publisher Elsevier India , Title Hutchisons Clinical Methods Edition Michael Glyn Author 24Th Ed Publisher Elsevier India , Title Hutchisons Clinical Methods Edition Michael Glyn Author 24Th Ed Publisher Elsevier India , Title Hutchisons Clinical Methods Edition Michael Glyn Author 24Th Ed Publisher Elsevier India , Title Hutchisons Clinical Methods Edition Michael Glyn Author 24Th Ed Publisher Elsevier India , Title Diseases Of Chest Edition Matsushima Author 1St Publisher Thieme Germany , Title Diseases Of Chest Edition Matsushima Author 1St Publisher Thieme Germany , Title Diseases Of Chest Edition Matsushima Author 1St Publisher Thieme Germany , Title Respiratory Infection Edition Antoni.Torres Author -- Publisher Dder, Arno , Title Respiratory Infection Edition Antoni.Torres Author -- Publisher Dder, Arno , Title Respiratory Infection Edition Antoni.Torres Author -- Publisher Dder, Arno , Title Kelley’S Textbook Of Rheumatology Edition Gary S. Firestein Author 9Th Publisher Elsevier , Title The Echo Manual Edition A Jamil Tajik Author 3Rd Publisher Wolters Kluwer , Title Hurst’S The Heart Edition Valentin Fuster Author 14Th , Title Harrisons Internal Medicine Edition Jameson Fauci Kasper Author 20Th Publisher Mc Graw Hill , Title Bates Guide To Physical Examination Edition Uzma Firdous Author South Asian Editionn Publisher Wolters Kluwer , Title Sleisvenger And Fordtran’S Gastro Intestine And Liver Diseases Edition Emad Qayad Shanti’S Erivasan Author 10Th Publisher Elsevier , Title Fishman’S Plumonary Diseases And Disorder Edition Michael A. Grippi Jack A. Elias Author 5Th Publisher Cbs , Title 104 Clinical Cases In Medicine Presentation And Discussionfor Undergraduate Students Edition Chugh Author Latest Edition Publisher Cbs , Title 258 Clinical Cases In Medicine: For Md, Dnb And Mrcp Examinations ( Pb ) Edition Chugh Author Latest Edition Publisher Cbs , Title Physical Signs, Symptoms, Diagnosis And Differential Diagnosis In Clinical Medicine ( Pb ) Edition Chugh Author Latest Edition Publisher Cbs , Title Manual Of Clinical Medicine ( Pb ) Edition Chugh Sn Author Latest Edition Publisher Cbs , Title Encyclopedia Of Behavioral Medicine 2Ed ( Hb ) Edition Gellman M D Author Latest Edition Publisher Springer , Title Fatigue In Multiple Sclerosis ( Pb ) Edition Krupp Author Latest Edition Publisher Elsevier Science ( Medical ) , Title Krygers Sleep Medicine Review: A Problem-Oriented Approach, 3E ( Pb ) Edition Kryger Author Latest Edition Publisher Elsevier Science ( Medical ) , Title Principles And Practice Of Sleep Medicine, 7E 2 Vol Set ( Hb ) Edition Kryger M.H. Author Latest Edition Publisher Cbs , Title Comprehensive Cardiovascular Medicine In The Primary Care Setting, 2E ( Hb ) Edition Toth Author Latest Edition Publisher Springer Humana , Title Nutrition & Oral Medicine, 2E ( Hb ) Edition Touger-Decker Author Latest Edition Publisher Springer , Title Glomerulonephritis ( Hb ) Edition Trachtman Author Latest Edition Publisher Springer , Title Heart Rate & Rhythm ( Hb ) Edition Tripathi Author Latest Edition Publisher Springer , Pathology , Author Damjanov Title / Name Of The Book Andersons Pathology Edition 10Th Publisher R.E , Author Tejinder Singh Title / Name Of The Book Atlas And Text Of Hematology Edition 3Rd Publisher R.E , Author Cagle Title / Name Of The Book Basic Concepts Of Molecular Pathlogy Edition Latest Edition Publisher Springer , Author Bibbo Title / Name Of The Book Comprehensive Cytopathology Edition 4Th Publisher , Author Edmund S. Cibas Title / Name Of The Book Cytology Edition 5Th Publisher R.E , Author Bain Title / Name Of The Book Dacie And Lewis Practical Hematology Edition 12Th Publisher R.E , Author Gray Title / Name Of The Book Diagnostic Cytopathology Edition 3Rd Publisher R.E , Author Beck Title / Name Of The Book Dignostic Hematology Edition Latest Edition Publisher Springer , Author Fletcher Title / Name Of The Book Diagnostic Histopathology Of Tumors Edition 4Th Publisher Elsevier , Author Simpson Title / Name Of The Book Differential Diagnosis In Surgical Pathology: Breast Edition Latest Edition Publisher Lww , Author Monotogomery Title / Name Of The Book Differential Diagnosis In Surgical Pathology: Gastrointensinal System Edition Latest Edition Publisher Lww , Author Khurana Title / Name Of The Book Essentials In Bone And Soft Tissue Pathology Edition Latest Edition Publisher Springer , Author Kocjain Title / Name Of The Book Fine Needle Aspirations Cytology: Diagnostic Principls Dilemmas Edition Latest Edition Publisher Springer , Author Ajmini Title / Name Of The Book Handbook Of Clinical Labortory Practice Surgical Pathology Edition Latest Edition Publisher Aitbs , Author Koss Title / Name Of The Book Koss Diagnostic Cytology And Its Histopathologic Bases Edition 5Th Publisher W. K , Author Orell Title / Name Of The Book Orell And Sterretts Fine Needle Aspiration Cytology Edition 5Th Publisher R.E , Author Shariff Title / Name Of The Book Principles And Interpretation Laboratory Practice Surgical Pathology Edition Latest Edition Publisher Jaypee , Author Saxena Title / Name Of The Book Recent Advances In Hematology Edition Vol-3 Publisher Jaypee , Author Underwood Title / Name Of The Book Recent Advances In Histopathology Edition Vol-22 Publisher Rsm , Author Kumar Title / Name Of The Book Robbins And Cortan Pathologic Basis Of Disease Edition S-A Edition Publisher R.E , Author Davidson Title / Name Of The Book Serious Effusions Edition Latest Edition Publisher Springer , Author Kalyuzhny Title / Name Of The Book Signal Transduction Immunohistochemistry: Methods And Protocos Edition Latest Edition Publisher Springer , Author Tejinder Singh Title / Name Of The Book Text And Practical Hematology For Mbbs Edition Latest Edition Publisher Arya , Author Godkar Title / Name Of The Book Textbook Of Medical Laboratory Technology Edition 3Rd Publisher Bhalani , Author Mandal Title / Name Of The Book Textbook Of Pathology For Mbbs Edition 2Nd Publisher Apc , Author Harsh Mohan Title / Name Of The Book Textbook Of Pathology Free Pathology Quick Review Edition 8Th Publisher Jaypee , Author Lewis Title / Name Of The Book The Molecular And Clinical Pathology Of Neurodegenerative Disease Edition Latest Edition Publisher Ap , Author Young Title / Name Of The Book Wheatrs Basic Pathology: A Text, Atlas And Review Of Histopathology: With Student Consult Online Access Edition 5Th International Edition Publisher Elsevier , Author Lokuhetty Title / Name Of The Book Who Classification Of Tumors Of Soft Tissue And Bone Edition 5Th Publisher Who , Author Fletcher Title / Name Of The Book Who Classification Of Tumors Of Soft Tissue And Bone Edition 4Th Publisher Who , Author Fischbach F.T. Title / Name Of The Book Fischbachs A Manual Of Laboratory And Diagnostic Tests 11Ed ( Ie ) ( Pb ) Edition Latest Editionpublisher Lippincott , Author Fisher Title / Name Of The Book Atlas Of Soft Tissue Tumor Pathology ( Hb ) Edition Latest Edition Publisher Springer , Author Fletcher C.D.M. Title / Name Of The Book Diagnostic Histopathology Of Tumors 2 Vol Set 5Ed ( Hb 2021 ) Edition Latest Edition Publisher Elsevier Science ( Medical ) , Author Flynn J.C. Title / Name Of The Book Procedures In Phlebotomy, 4E ( Pb ) Edition Latest Edition Publisher Elsevier Science ( Medical ) , Author Fogo Title / Name Of The Book Fundamentals Of Renal Pathology 2E ( Hb ) Edition Latest Edition Publisher Springer , Author Fogo A.B. Title / Name Of The Book Diagnostic Atlas Of Renal Pathology With Access Code 4Ed ( Hb ) Edition Latest Edition Publisher Elsevier Science ( Medical ) , Author Folpe Title / Name Of The Book Bone & Soft Tissue Pathology: A Volume In The Series Foundations In Diagnostic Pathology ( Hb ) Edition Latest Edition Publisher Elsevier Science ( Medical ) , Author Font Title / Name Of The Book Tumors Of The Eye And Ocular Adnexa 5 ( Hb ) Edition Latest Edition Publisher Arp , Orthopaedic Department , Campbells Operative Orthopaedics 14Th Edition , Rockwood And Greens Fractures In Adults 9Th Edition , Rockwood And Wilkins Fractures In Children -9Th Edition , Apley & Solomons System Of Orthopaedics And Trauma -10Th Edition , Tureks Orthopaedics Principles And Their Applications, 7 / E, , Traction And Orthopaedic Appliances By John D.M. Stewart 3 / E , The Closed Treatment Of Common Fractures By John Charnley , Mcraes Orthopaedic Trauma And Emergency Fracture Management , Handbook Of Fractures 6Th Edition / By Kenneth Egol, Kenneth J. Koval & Joseph D. Zuckerman , Clinical Orthopaedic Examination By Mcrae Ronald , Handbook For Orthopaedics Examination By Kaushik Banerjee 7 / E , A Manual On Clinical Surgery 13Ed : Das S , Orthopaedic Neurology: A Diagnostic Guide To Neurologic Levels By Stanley Hoppenfeld , Physical Examination Of The Spine And Extremities By Stanley Hoppenfeld , Surgical Exposures In Orthopaedics: The Anatomic Approach By Stanley Hoppenfeld , Ao Principles Of Fracture Management: Vol. 1: Principles, Vol. 2: Specific Fractures By Christopher G. Moran, Richard E. Buckley, And Theerachai Apivatthakakul , Master Techniques In Orthopaedic Surgery: Fractures , Master Techniques In Orthopaedic Surgery: Knee Arthroplasty , Master Techniques In Orthopaedic Surgery: Orthopaedic Oncology And Complex Reconstruction , Master Techniques In Orthopaedic Surgery: Pediatrics , Master Techniques In Orthopaedic Surgery: Reconstructive Knee Surgery , Master Techniques In Orthopaedic Surgery: Relevant Surgical Exposures , Master Techniques In Orthopaedic Surgery: Soft Tissue Surgery , Master Techniques In Orthopaedic Surgery: Sports Medicine , Master Techniques In Orthopaedic Surgery: The Elbow , Master Techniques In Orthopaedic Surgery: The Foot And Ankle , Master Techniques In Orthopaedic Surgery: The Hand , Master Techniques In Orthopaedic Surgery: The Hip , Master Techniques In Orthopaedic Surgery: The Shoulder , Master Techniques In Orthopaedic Surgery: The Spine , Master Techniques In Orthopaedic Surgery: The Wrist , Lasts Anatomy, Regional And Applied Book By R. Last , Grays Anatomy: The Anatomical Basis Of Clinical Practice , Netters Concise Orthopaedic Anatomy Book By Jon C. Thompson , Grants Atlas Of Anatomy, 14 / E , Tuberculosis Of The Skeletal Systemby Sm Tuli , Practical Orthopedic Examination Made Easy Manish Kumar Varshney , Essential Orthopedics Principles & Practice ( 2Vols ) By Manish Kumar Varshney , Postgraduate Orthopedics: An Exam Preparatory Manual By Manish Kumar Varshney , Elements Bd Chaurasias Handbook Of General Anatomy , Bailey & Loves Short Practice Of Surgery Book By Henry Hamilton Bailey , Knee Arthroscopy : Brian P. Mckeon , Tuberculosis Of Skeletal System By A. K Jain 1St Edition , Macnabs Backache Book By David A. Wong And Ensor Transfeldt 4 / E , Essential Orthopaedics: Including Clinical Methods Book By J. Maheshwari And Vikram A Mhaskar 6 / E , Basic Knee And Hip Arthroplasty By Shrinand V. Vaidya 2 / E , Decision Making In Orthopaedic Trauma By Meir T. Marmor , Tachdjians Pediatric Orthopaedics: From The Texas Scottish Rite Hospital For Children , Hip Fractures: A Practical Guide To Management Book By Joseph D. Zuckerman And Kenneth J Koval , How To Unleash Your Potential And Achieve Success - The Key Soft Skills By Abdul Ghani , Total Knee Arthroplasty Book By Richard D. Scott , Millers Review Of Orthopaedics By Mark D Miller , Textbook Of Orthopaedics Textbook By John Ebnezar , Bridwell And Dewalds Textbook Of Spinal Surgery , Mercers Textbook Of Orthopaedics And Trauma , Management Of Orthopaedic Infections: A Practical Guide: Chen, Antonia , Greens Operative Hand Surgery- 7Th Edition , K-Wiring : Principles And Techniques By C. Rex , Fracture Reduction And Fixation Techniques By Pv Giannoudis , Atlas Of Orthopaedic Surgical Exposures Book By Christopher Jordan , Principles Of Deformity Correction Book By Dror Paley , Limb Lengthening And Reconstruction Surgery By Robert Rozbruch , Chapmans Comprehensive Orthopaedic Surgery , Textbook Of Orthopedics And Trauma ( 4 Volumes ) Textbook By G. S. Kulkarni , Coughlin And Manns Surgery Of The Foot And Ankle10th Edition , Congenital Clubfoot: Fundamentals For Treatment By Ignacio Ponseti , Manual Of Arthroscopic Surgery Book By Michael Strobel , Arthroscopy By Pietro Randelli , Dorfman And Czerniaks Bone Tumors - 2Nd Edition
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
32.
Public Administrative Department #10131078 Price Bid
Tender For Hundpump Tubewell Work , Construction Of Tube Well From Ground Level & Up To 100 Mtr Depth To Accommodate Housing And Assembly Pipe Of Following Sizes In All Type Of Alluvium Strataunconsolidated Formation Such As Pebbles, Boulders Etc. By Percussion / Rotary Drilling Method As Per Is:2800 Part 1: 1991 Andis:2800 Part Ii: 1979 ( Both Amended Upto Date ) And Technical Specifications, With Gravel As Per Is:4097-1967 And Its Packing As Per Is: 2800 ( Part I & Ii ) 1979 As Amended Up To Date ( The Work Includes The Cost Of Gravel & Its Primary Packing And Packing During Development, Lowering Of Housing & Strainer Assembly Pipes With Supply And Wrapping Of Coir-Rope, Wherever Necessary For Arresting Fine Sand Particles And Development Work, But Excluding The Cost Of Housing And Strainer Pipe Assembly ) . The Work Would Be Completed After Obtaining Sand Free Water. , Nominal Bore 150 Mm Dia. , Nominal Bore 200 Mm Dia. , Nominal Bore 250 Mm Dia. , Add 15% Extra On Depth More Than 100 Mtr For Drilling Beyond 100 Mtr Depth From Ground Level. , Construction Of Tube Well From Ground Level And Upto 100 Mtr. Depthto Accommodate Housing And Assembly Pipe In All Type Of Alluvium Strata, Unconsolidated Formation Such As Pebbles, Boulders Etc. By Percussion / Rotary Drilling Methodas Per Is:2800 Part 1: 1991 Andis:2800 Part Ii: 1979 ( Both Amended Upto Date ) And Technical Specifications For Removal Of Overburden. The Work Includes The Cost Oflowering Of Casing Pipe, But Excludes The Cost Of Casingpipe. , Nominal Bore 200 Mm Dia. , Nominal Bore 250 Mm Dia. , Add 15% Extra On Depth More Than 100 Mtr For Drilling Beyond 100 Mtr Depth From Ground Level. , Construction Of Tube Well After Completion Of Drilling By Rotary Method & Upto 150 Mtr. Depthin All Type Of Rocks By Dth Systemas Per Is:2800 Part 1: 1991 Andis:2800 Part Ii: 1979 ( Both Amended Upto Date ) And Technical Specifications. The Workshall Be Deemed Completed Only After Obtaining Sand Free Water. The Bore Well Should Have A Throughout Nominal Size Bore Beyond Casing Pipe. , Nominal Bore 150 Mm Dia. , Nominal Bore 200 Mm Dia. , Add 15% Extra On Depth More Than 150 Mtr For Drilling Beyond 150 Mtr Depth From Ground Level. , Construction Of Tube Well Up To 150 Mtr. Depthin All Type Of Rocks By Dth System & Over Burden To Accommodate Casing Pipe Of Following Sizes In All Types Of Soil & Over Burden Including Lowering Of Casing Pipe, ( If Required ) Excluding Cost Of Casing Pipe, As Per Is:2800 Part 1: 1991 Andis:2800 Part Ii: 1979 ( Both Amended Upto Date ) And Technical Specifications. The Work Would Be Completed After Obtaining Sand Free Water. The Tube Well Should Have A Through Out Bore As Per Nominal Dia Of Casing Pipe. , Nominal Bore 150 Mm Dia. , Nominal Bore 200 Mm Dia. , Add 15% Extra On Depth More Than 150 Mtr For Drilling Beyond 150 Mtr Depth. , Construction Of Tube Well From Ground Level And Upto 100 Mtr. Depth And Above Of Following Sizes In All Types Of Soils In Alluvium Strata, Unconsolidated Formation Such As Pebbles, Boulders Etc. By Bailing Method And Without Gravel Packing As Per Is:2800 Part 1: 1991 Andis:2800 Part Ii: 1979 ( Both Amended Upto Date ) And Technical Specifications. The Work Includes Formation Of Cavity At Bottom By Development With Appropriate Air Compressor Or Bailer Pumping And Also Lowering Of Casing Pipe But Excluding Cost Of The Casing Pipe.The Tube Well Should Have A Throughout Bore As Per Nominal Dia Of Casing Pipe.The Work Would Be Completed After Obtaining Sand Free Water. , Nominal Bore 125 Mm Dia. , Nominal Bore 150 Mm Dia. , Nominal Bore 200 Mm Dia. , Construction Of Tube Well From Ground Level And Up To 100 Mtr Depth And Above To Accommodate Housing Assembly Pipe In All Type Of Unconsolidated Formation Such As Pebbles, Boulders, Collapsible Formation Etc. By Odex Drilling Method As Per Is:2800 Part 1: 1991 Andis:2800 Part Ii: 1979 ( Both Amended Upto Date ) And Technical Specifications. The Work Will Include Lowering Of Housingand Strainer Pipe Assembly And Casing Shoe Incuding Cost Of Casing Shoe, But Excluding Cost Of The Casing Pipe. The Work Would Be Completed Afterobtaining Sand Free Water. , Nominal Bore 125 Mm Dia. , Nominal Bore 150 Mm Dia. , Nominal Bore 200 Mm Dia. , Deepening Of Existing Tube Well By Dth System Beyond Existing Depth Upto 100 Mtr. And Above In All Type Of Rocks Including Flushing Of Tube Well And Obtaining Sand Free Water. , Nominal Bore 150 Mm Dia. , Nominal Bore 200 Mm Dia. , Testing Verticality Of Tube Well By Plumbing System And Yield Test And Draw Down Test By Pumping System As Per Is : 2800 ( Part – Ii ) – 1979 Or As Amended Up To Date. , Supplying & Packingp-Gravel Suitable For Slot Size / Mesh Size As Suggested In Is 2800 ( Part-1 ) 1991 Or As Amended Up To Date. , Development Of Tube Well As Per Is: 11189- 1985 And Is: 2800 ( Part- I ) - 1991 ( Both Amended Up To Date ) Using Suitable Compressor To Give Sand Free Water For Required Yield Of The Gravel Packed Tube Well. , Supply Of Erw M.S. Black Casing Pipe Isi Marked ( Is: 4270 / 2001 ) Or Amended Up To Date Offollowing Sizes , 150 Mm Dia Nb ( Thickness Of Pipe 5.0 Mm & Mass Of Tube 20.13 Kg / M ) , 200 Mm Dia Nb ( Thickness Of Pipe 5.4Mm & Mass Of Tube 28.46 Kg / M ) , 250 Mm Dia Nb ( Thicknee Of Pipe 7.1 Mm & Mass Of Tube 46.57 Kg / M ) , Labour Charges For Making Slots On Blank Pipes Made Of Erw Ms Black Pipe Of Following Sizes, The Slotting Should Be As Per Is:8110-1985 Or As Amended Up To Date. , 125 Mm Dia Nominal Bore.Of 4.8 Mm Thickness , 150 Mm Dia Nominal Bore.Of 4.8 Mm Thickness , 200 Mm Dia Nominal Bore.Of 5.4 Mm Thickness , 250 Mm Dia Nominal Bore.Of 7.1 Mm Thickness , Providing & Laying Isi Marked Gi Pipe Light Duty ( “A” Class ) As Peris: 1239For Casing Pipe For Submersible Cable External Work 40 Mm Dia Complete In All Respect. , Supply & Installation Of Single Phase Isi Marked Submersible Motor Pump Set Of Five Star Rating By Bee And As Per Is: 8034-2018 ( Pump ) And Is 9283-2013 ( Motor ) Or As Amended Up To Date Of Approved Make Of Following Duty Condition With Required Accessories Including Making Connection Suitable For Tube Well / Dcb. The Job Includes Lowering Of Motor Pump, Installation Of Complete Fitting & Accessories, Jointing Of Electrical Cables Up To Switch Board, Testing Of Submersible Pump Set And Interconnection Up To Water Mains, Complete In All Respect. , Up To 2.0 Kw , Above 2.0 Kw , Supply & Installation Of 3 Phase Isi Marked Submersible Motor Pump Set Offive Star Rating By Bee And As Per Is: 8034-2018 ( Pump ) And Is 9283-2013 ( Motor ) Or As Amended Up To Date Of Approved Make Of Following Duty Condition With Required Accessories Including Making Connection Suitable For Tube Well / Dcb. The Job Includes Lowering Of Motor Pump, Installation Of Complete Fitting & Accessories, Jointing Of Electrical Cables Up To Switch Board, Testing Of Submersible Pump Set And Interconnection Up To Water Mains, Complete In All Respect. , Up To 5.5 Kw ( 7.5 Hp ) & Head Above 120 Mtr. , Up To 5.5 Kw ( 7.5 Hp ) & Head Above 120 Mtr. , 7.5 Kw ( 10 Hp ) & Head Up To 120 Mtr. , 7.5 Kw ( 10 Hp ) & Head Above 120 Mtr. , 9.3 Kw ( 12.5 Hp ) & Head Up To 120 Mtr. , 9.3Kw ( 12.5 Hp ) & Head Above 120 Mtr. , 11 Kw ( 15 Hp ) & Head Up To 120 Mtr. , 11 Kw ( 15 Hp ) & Head Above 120 Mtr. , 13 Kw ( 17.5 Hp ) & Head Up To 120 Mtr. , 13 Kw ( 17.5 Hp ) & Head Above 120 Mtr. , 15 Kw ( 20 Hp ) And Above, Head Up To 120 Mtr. , 15 Kw ( 20 Hp ) And Above, Head Above 120 Mtr. , Supply And Fixing Of Electric Feeder Panel ( Having Projected Canopy ) For Submersible Pump Set Single Phase Upto 3 Hp, Comprising Of Dol Starter, Mcb, Indicating Light, Ammeter, Volt Meter, Connection Plate, Condensers Of Approved Make And The Panel Enclosure Should Be Made Out From 18 Guage M.S. Sheet With Powder Coating. Panel Size - Height 600 Mm, Width 500 Mm And Depth 250 Mm With Stand ( Made Of Angle Iron Of Size 35X35x5mm ) Duly Bolted / Screwed With Enclosure Box Having 4 Legs, Each Leg’S Length 18 And Double Door Including In Built Locking System.The Legs Should Be Embedded In M-15 Cement Concrete Platform.The Size Of Cc Platform Should Be Equal Or Bigger Than The Base Size Of Panel Having Height Of At Least 200 Mm From Ground Level. The Operation Of Panel Should Be Suitable For240 Volt Ac Supply. , Supply And Fixing Of Electric Control Feeder Panel Comprising Of Suitable Rating Mccb, Dol Starter, Overload Relay, Ampere Meter, Volt Meter, Phase Preventer, Phase Indicators, Lighting Arrangement Etc Complete Suitable For Three Phase Pump Set. The Panel Should Have Space For Energy Meter ( Supplied By Discom ) . All These Equipments Shall Be Housed By Panel Box Made Out From 18 Guage M.S. Sheet With Powder Coating. Panel Should Be Ofminimum Size 900 X 600 X 300Mm With Stand ( Made Of Angle Iron Of Size 35X35x5mm ) Duly Bolted / Screwed With Enclosure Box Having 4 Legs, Each Leg’S Length 18 And Double Door Including In Built Locking System.The Legs Should Be Embedded In M-15 Cement Concrete Platform.The Size Of Cc Platform Should Be Equal Or Bigger Than The Base Size Of Panel Having Height Of At Least 200 Mm From Ground Level.The Panel Should Have Opening Of Suitable Size In Front Of Space For Energy Meter With Glass For Meter Reading. The Operation Of Panel Should Be Suitable For440 Volt Ac Supply. , Up To 5.00 Hp , Supply And Fixing Of Electric Control Feeder Panel Comprising Of Suitable Rating Mccb , Fully Automatic Star-Delta Starter, Over Load Relay, Ampere Meter With Cts, Volt Meter, Phase Preventor, Suitable Starting Capacitors, Phase Indicators, Lighting Arrangement Etc Complete Suitable For Three Phase Pump Set. The Panel Should Have Space For Energy Meter ( Supplied By Discom ) .All These Equipments Shall Be Housed By Panel Box Made Out From 18 Guage M.S. Sheet With Powder Coating. Panel Should Be Ofminimum Size 900 X 600 X 450 Mm With Stand ( Made Of Angle Iron Of Size 35X35x5mm ) Duly Bolted / Screwed With Enclosure Box Having 4 Legs, Each Leg’S Length 18 And Double Door Including In Built Locking System.The Legs Should Be Embedded In M-15 Cement Concrete Plat Form.The Size Of Cc Plateform Should Be Equal Or Bigger Than The Base Size Of Panel Having Height Of At Least 200 Mm From Ground Level. The Panel Should Have Opening Of Suitable Size In Front Of Space For Energy Meter With Glass For Meter Reading. The Operation Of Panel Should Be Suitable For440 Volt Ac Supply. , Above 5 Hp And Up To 10 Hp , Above 10 Hp And Up To 15 Hp , Above 15 Hp , Supply & Fixing Of Isi Marked Three Core Pvc Flat Submersible Cableas Per Is 694:1990 Or Amended Up To Date And Conductor As Per Class 5 Of Is 8130:1980Including Making Connection Etc. , 3 Core 4.0 Sq.Mm , 3 Core 6.0 Sq.Mm , 3 Core 10.0 Sq.Mm , 3 Core 16.0 Sq.Mm , Supply & Fixing Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Makein Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Underlayer Ofsand, Second Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size. , 10 Sq.Mm, 4 Core , 16 Sq.Mm, 4 Core , 25 Sq.Mm, 3.5 Core , 35.0 Sq.Mm, 3.5 Core , Plate Earthing As Per Is:3043 With G.I. Earth Plate Of Size 600Mm X 600Mm X 6.0Mm By Embodying3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe Including All Accessories Like Nut, Bolts, Reducer , Nipple, Wire Meshed Funnel, And C.C.Finished Chamber Covered With Hinged Type With Locking Arrangement C.I. Cover, C.I. Frame Of Size 300Mm X 300Mm Complete With Alternate Layers Of Salt And Coke / Charcoal, Testing Of Earth Resistance As Required. , Supply & Fixing M S Clamp Set Of 50X6 Mm Flat From Iron With Nuts And Bolts Etc For Holding The Riser Pipe Assembly Of Submersible Pump Set. , Supply & Fixing Tube Well Coverof Ms Sheet 8Mm Thick At Top & 5Mm Thick 100Mm Wide Shroud Around The Edge So As To Form A Cap On The Top End Of Casing Pipe With Gi Nipple 45Cm Long & Two Gi Flanges At Both Ends In 80Mm Sizes Passing Through A Hole In The Centre Of Ms Sheet. A 25 Mm Socket With End Plug Shall Also Be Welded Over Top Plate. A Gi Nipple Having Outside Thread Of Size 1 / 2 ( For Installation Pressure Gauge ) Shall Be Provided & Welded With 80Mm Gi Nipple Near Top Plate Nipple Shall Be Provided With End Plug. , 125 Mm Dia , 150 Mm Dia , 200 Mm Dia , 250 Mm Dia , Providing & Lowering In Tubewell Isi Marked Gi Pipe “B ( Medium ) Class As Per Is:1239 Part I 2004 Or Amended Up To Date, Threaded And Double Flanged ( Welded ) On Both Ends And Two Number25x3mm Ms Flat Welded On Both Ends Between Pipe & Flange, Rubber Washer & Nut Bolts Etc. Complete In All Respect. , 32 Mm Dia , 50 Mm Dia , 65 Mm Dia , 80 Mm Dia , Providing & Lowering In Tubewell Isi Marked Hdpe Pipe As Per Is 4984:1995 Or Amended Upto Date In Pe 80 Grade And Class Pn 10 Of Following Dia. Including Hdpe / Gi Fittings And Pvc Rope Confirming To Is 5175:1992 Or Amended Upto Date, Along With Clamping Of Submersible Cable Etc. Complete In All Respect. , 40 Mm Dia , 50 Mm Dia , 63 Mm Dia , 75 Mm Dia , 90 Mm Dia , Providing, Installing, Testing And Commissioning Of Double Flanged Bulk Flow Meter With Removable Mechanism, Of Class B Conforming To Iso 4064 / 1 Or Amended Upto Date Of Approved Make Including Cost Of All Material Andlabouras Per Specifications With Gi Box ( Sheet 16 Swg ) Suitable With Locking Arrangement Of Following Dia. , 50 Mm Dia , 65 Mm Dia , 80 Mm Dia , Providing & Fixing Pump Safety Cage As Per Specifications Or As Directed By Engineer In Charge. , Providing And Fixing Of Isi Marked Pvc Storage Tank Of Following Capacityas Per Is: 12701-1989 ( Of Approved Make ) With Cover, 25 Mm Dia. 1 Mtr Long Gi Overflow Pipe, 25 Cm Long 25 Mm Dia Washout Gi Pipe With Plug & Socket, Including P&F 32 Mm Dia Ball Cock ( Float Valve ) Is 1703 Marked With Rod And Pvc Ball Complete With Brass Weight 1000 Gm, Including P&F 15Mm Dia Ci Quarter Turn Heavy Duty Bib Cocks Four Nos Of Superior Quality And Approved Make, Including Interconnections Complete Job. , 1000 Litres Capacity , 2000 Litres Capacity , Fabrication & Fixing M.S.Stand Of Specified Class Of Angle Iron L-Shaped Of 50 Mm Size With Four Legs Grouted By 300*300*300 Mm Cc Block M-15 In The Ground And All Legs Tied Up With Each Other Through Same Size Of Angle Iron Along With Cross Bars To Support The Bottom Of 1000 Ltr. / 2000 Ltr. Pvc Tank Complete In All Respect. , Providing & Fixing Of Double Flanged, Ci Body, Isi Marked Nrv Of Approved Make Of Following Sizes , 65 Mm Dia , 80 Mm Dia , Proving And Fixing 32 Mm Dia Full Way Valve Or Wheel Valve As Per Is:778 Or Amended Up To Date Of Approved Make, On Pump Delivery Pipe. , Supplying & Installing 100 Mm Diameter Sealed Diaphragm Bourdon Type Pressure Gauge Of Range 0 To 10 Kg.Including All Jointing Material As Per Specification With Safety Cover. , Construction Of Bore Hole For Shallow Depth Tube Well From Ground Level To Required Depth For Following Size For All Type Of Relevant Strata By Percussion / Rotary Drilling / Hand Boring Method Excluding Cost Of Casing Pipe. Thebore Hole Should Be As Per Nominal Bore Of Pvc Casing Pipe. The Work Will Be Complete After Obtaining Sand Free Water. , Providing And Lowering Of Isi Mark Pvc-U Casing And Screen Pipe As Per Is : 12818 : 2010 Or Amended Upto Date Having Pipe Thickness As Per Is Code Suitable For Tw And Dcb With Threading , Winding With Superior Quality Of Plastic Mesh & Rope In Three Layers With End Cap Complete As Per Technical Specification And Direction Of Engineer In Charge. , Shallow Well Casing Pipe ( Cs ) Suitable For Depth Up To 80 Mtr. , 150 Mm Nominal Dia ( Internal Dia ) . , 200 Mm Nominal Dia ( Internal Dia ) . , 250 Mm Nominal Dia ( Internal Dia ) . , Medium Well Casing Pipe ( Cm ) Suitable For Depth Above 80 Mtr And Up To 250 Mtr. , 100 Mm Nominal Dia ( Internal Dia ) . , 125 Mm Nominal Dia ( Internal Dia ) . , 150 Mm Nominal Dia ( Internal Dia ) . , 200 Mm Nominal Dia ( Internal Dia ) . , 250 Mm Nominal Dia ( Internal Dia ) . , Supply Of Isi Mark Ac Pressure Pipe Class 15 Manufactured By Mazza Process As Per Is:1592-2003 Or Amended Upto Date, For Casing Of Tube Wellfor Following Dia Nominal Bore, With Jointing Material Pvc Coupler As Per Technical Specification And Direction Of Engineer In Charge. , 125 Mm Nominal Dia , 150 Mm Nominal Dia , 200 Mm Nominal Dia , 250 Mm Nominal Dia , 300 Mm Nominal Dia , Making Slots Of Hole Size And Nos. As Directed By Eic In Ac Pressure Pipe Class 15 As Per Technical Specification For Using Slotted Pipe In Tw Casing. , Construction Of Tube Well From Ground Level & Up To 100 Mtr Depth To Accommodate Housing And Assembly Pipe Of Following Sizes In All Type Of Alluvium Strataunconsolidated Formation Such As Pebbles, Boulders Etc. By Percussion / Rotary Drilling Method As Per Is:2800 Part 1: 1991 Andis:2800 Part Ii: 1979 ( Both Amended Upto Date ) And Technical Specifications, With Gravel As Per Is:4097-1967 And Its Packing As Per Is: 2800 ( Part I & Ii ) 1979 As Amended Up To Date ( The Work Includes The Cost Of Gravel & Its Primary Packing And Packing During Development, Lowering Of Housing & Strainer Assembly Pipes With Supply And Wrapping Of Coir-Rope, Wherever Necessary For Arresting Fine Sand Particles And Development Work, But Excluding The Cost Of Housing And Strainer Pipe Assembly ) . The Work Would Be Completed After Obtaining Sand Free Water. , Nominal Bore 125 Mm Dia. , Add 15% Extra On Above Item For Drilling Depth Beyond 100 Mtr, If Depth Of Bore Is More Than 100 Mtr. , Construction Of Tube Well Up To 100 Mtr. Depthin All Type Of Rocks By Dth System & Over Burden To Accommodate Casing Pipe Of Following Sizes In All Type Of Soils & Over Burden Including Lowering Of Casing Pipes, ( If Required ) Excluding Cost Of Casing Pipes, As Per Is:2800 Part 1: 1991 Andis:2800 Part Ii: 1979 ( Both Amended Upto Date ) And Technical Specifications. The Work Would Be Completed After Obtaining Sand Free Water. The Tube Well Should Have A Throughout Bore As Per Nominal Dia Of Casing Pipe. , Nominal Bore 125 Mm Dia. , Nominal Bore 125 Mm Dia. , Add 15% Extra On Above Item For Drilling Depth Beyond 100 Mtr, If Depth Of Bore Is More Than 100 Mtr. , Construction Of Tube Well From Ground Level And Upto 100 Mtr. Depth And Above Of Following Sizes In All Types Of Soils In Alluvium Strata, Unconsolidated Formation Such As Pebbles, Boulders Etc. By Bailing Method And Without Gravel Packing As Per Is:2800 Part 1: 1991 Andis:2800 Part Ii: 1979 ( Both Amended Upto Date ) And Technical Specifications. The Work Includes Formation Of Cavity At Bottom By Development With Appropriate Air Compressor Or Bailer Pumping And Also Lowering Of Casing Pipe But Excluding Cost Of The Casing Pipe.The Tube Well Should Have A Throughout Bore As Per Nominal Dia Of Casing Pipe.The Work Would Be Completed After Obtaining Sand Free Water. , Nominal Bore 100 Mm Dia. , Nominal Bore 125 Mm Dia. , Supply Ofm.S. Black Casing Pipe Isi Marked As Per Is: 1239 ( Part 1: 2004 ) Or Amended Up To Date Offollowing Sizes: , 100 Mm Dia Nb ( Thickness Of Pipe 4.8 Mm & Mass Of Tube 16.40 Kg / M ) , 125 Mm Dia Nb ( Thickness Of Pipe 4.8 Mm & Mass Of Tube 16.40 Kg / M ) , Providing And Lowering Of Isi Mark Medium Wellpvc-U Casing And Screen Pipe ( Cm ) As Per Is : 12818 : 2010 Or Amended Upto Date Having Pipe Thickness As Per Is Code Suitable For Bore Well With Threading , Winding With Superior Quality Of Plastic Mesh & Rope In Three Layers With End Cap Complete As Per Technical Specification And Direction Of Engineer In Charge. , 100 Mm Nominal Dia ( Internal Dia ) . , 125 Mm Nominal Dia ( Internal Dia ) . , Labour Charges For Making Slots On Blank Pipes Made Of Erw Ms Black Pipe Isi Marked Of Following Sizes, The Slotting Should Be As Per Is:8110-1985. , 100 Mm Dia Nominal Bore , 125 Mm Dia Nominal Bore , Supply & Installation Of Gi Pipe 32 Mm Medium Class “B” With Pipe Sockets ( Heavy Duty ) . , Supply And Installation Of Isi Markeddeep Well Hand Pump- Standard ( Sdwp ) Setas Per Is 15500: 2004 Or As Amended Up To Date Complete With Cylinder & 15 Connecting Rods. , Supply And Installation Of Isi Marked India Mark Ii Hand Pump Set Extra-Deep ( Edw ) Completewith Cylinder And Connecting Rods. , Edwhp + 20 Connecting Rod. , Edwhp + 23 Connecting Rod + 1 Weight. , Edwhp + 26 Connecting Rod + 2 Weight. , Edwhp + 30 Connecting Rod + 3 Weight. , Supply And Installation Of Isi Mark Connecting Rod As Per Departmental Specifications Of3 Meter Length. , Installation Of Deep Well Hand Pump Set Complete On Existing Platform As Per Is 15500: 2004 Or As Amended Up To Date. , Construction Of 185 Cm. Dia Platform As Per Fig 1.1 Typical Set-Up For Deepwell Hand Pump Of Is 15500: 2004 Or Amended Up To Date Complete Work.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 1
33.
Public Administrative Department #10027101 Technical Bid
Tender for Item-Wise Rates Of Various Non-Schedule Items For Different Development Works / Renovation Of Conference Hall Of Paradeep Municipality. , Supply, Installation, Testing And Commissioning Of Electric High Speed Light Weight 50W 400 Mm Wall Fan Of White Colour Is A Space-Saving And Efficient Cooling Solution Designed For Optimal Air Circulation In Both Residential And Commercial Settings. Mounted On A Wall, These Fans Offer A Directed And Localized Breeze, Making Them Ideal For Spaces Where Floor Space Is Limited Or Where A Targeted Airflow Is Desired. Specification: Dimensions - 49.2D X 77.8W X 46.9H Centimeters, Noise Level-63 Db, Glossy Finish, Number Of Blades-01, Air Flow Capacity- 72 Cubic Meters Per Minute, Blade Length-400 Millimeters, Speed- 1.36E+3 Rpm, 230 Volts, Remote Type, Specification Met- Ce. Make- Havells/ Cg/ Bajaj , Supply, Installation, Testing And Commissioning Of Electric Single Phase Exhaust Fan 12Inch. Specification: 300Mm Exhaust Fan | Strong Air Suction, Rust Proof Body |Suitable For Bathroom, Kitchen, And Office. Product Dimensions 42D X 42W X 21.5H Cm, Special Feature Portable, Water Resistant, Waterproof. Make- Havells/ Cg/ Bajaj , Supply And Installation, Testing & Commissioning Of 5Kva (1Ph-1Ph) Online Double Conversion Ups Having 1Ph-1Ph With Inbuilt Isolation Transformer, With Ms Rack Rack , Dc Cable, Links With Two Years Warranty. With Back Up Of 60 Minutes. Make : Numeric - Legrand/ Delta/ Vertive Battery: For 60 Minutes Battery Back , Ms Rack, Linkd Dc Cable And Battery 12V/42Ah/16Nos.. Minimum Vah Reqd. 10080 Vah. Make-Exide Quanta / V-Guard/ Luminous , Water Purifier: Supply Of Ro Water Purifier 5 Stage Filtration, 50-55 Ltr/Hr. Capacity. Make- Lexpure/ Kent/ Livpure , Water Purifier:T Echnician Charges Towards Fitting, Fixing, Installation And Commissioning Of Ro Water Purifier 5 Stage Filtration, 50-55 Ltr/Hr. Capacity With Supply Of Clamp, Screw, Nut Bolt And Etc. As Per Requirement And Direction Of Engineer-In-Charge.Make- Lexpure/ Kent/ Livpure , Water Cooler : Supply Of 150 Ltr. Water Dispenser Is A Premium Product Suitable For Residential And Commercial Settings. Its Modern And Elegant Design Makes It A Versatile Addition To Any Space. Equipped With A 1/2 Bsp Thread Connection Type, This Dispenser Guarantees A Secure And Leak-Proof Installation. Boasting A Cooling Capacity Of 150 L/Hr, It Ensures A Constant Supply Of Cold Water. Crafted From High-Quality Stainless Steel, The Body Of This Dispenser Is Durable And Long-Lasting, Resistant To Corrosion, Rust, And Stains. Its Hot And Cold Modes Provide The Convenience Of Instant Access To Both Temperatures Of Water. 02 Nos.. Of Taps, 9.5 Rated Current, Stainless Steel Body. Item Depth (Mm)-589, Item Height (Mm)-1235, Item Weight (Kg)-64, Cooling Capacity (L/Hr)-150, Hot/Warm Water Dispensing Capacity-Na, Hot/Warm Water Dispensing Capacity Unit-Na, Cooling Storage Capacity (L)-150,Cooling Storage Capacity Unit-Liters, Normal Storage Capacity-Na, Normal Storage Capacity Unit-Na, Hot/Warm Water Storage Capacity-2, Hot/Warm Water Storage Capacity Unit-L, Package Width (Mm)-911, Package Depth (Mm)-690, Package Height (Mm)-1247, Package Weight (Kg)-74, Product Warranty-1 Year, Power Rating-Cooling (In Watts) 2100 @35C, Minimum Input Voltage Range 220 (Volts), Maximum Input Voltage Range-240 (Volts), Input Voltage Frequency (Hz)-50, Input Plug / Connector Type-3 Pin Plug , 16 Amp, Cord Length (Meters)-1.5, Function Cold | Warm, Refrigerant-R32, Usp Feature 1 Warm And Cold Dispensing Option, Usp Feature 2 Sturdy Compressor And Trouble Free Operation, Usp Feature 3 Eco- Friendly, Usp Feature 4 Silent Operation, Usp Feature 5 Food Grade Ss304 Tank. Make- Blue Star/ Kent/Usha , Water Cooler : Technician Charges Towards Fitting, Fixing, Installation And Commissioning Of 150 Ltr. Water Dispenser With Supply Of All Clamps , Screws, Nut Bolts And Etc. As Per Requirement And Direction Of Engineer-In-Charge. , Fire Extinguisher : Providing ,Fixing , Testing And Commissioning Of Carbon Dioxide (Co2) Type Fire Extinguisher, Isi Mark, Cap-4.5 Kg. Make - Safepro/Fire Shield , Fire Extinguisher : Providing ,Fixing , Testing And Commissioning Of Abc Type Fire Extinguisher, Isi Mark, Cap-6.0 Kg. Make - Safepro/Fire Shield , Fire Extinguisher : Providing ,Fixing , Testing And Commissioning Of Foam Type Fire Extinguisher, Isi Mark, Cap-9 Ltr. Make - Safepro/Fire Shield , Audio Visual Work : Supply Of Chairman Unit Long Unit- Digital With Chairman Button: Frequency Response:200 Hz To 12.5 Khz Headphones Load Impedance: 32 Ohms 1K Ohm Loudspeaker Nominal Output:72 Db special Length Of Microphone From Mounting Surface:480 Mm (18.9 In) Operating Temperature:0 ºc To +35 ºc Plug And Play Functionality For Ensuring Fast Installation And Reconfiguration Times Immunity To Mobile Phone Interference Functions Possible-To-Speak Indication Built-In Loudspeaker With Volume Control Headphones Socket: Built- In 3.5 Mm (0.14 In) Stereo Headphones Built-In Volume Control For Headphones Color-Coded Led Indicator Above Microphone Button For Showing The Following States: Microphone On, Request-To-Speak, And Possible-To-Speak Similar To Make Bosch Model No. Ccsd- Dl+Chairma N Button Complete. , Audio Visual Work : Supply Of Delegate Unit Long Unit- Digital Frequency Response:200 Hz To 12.5 Khz Headphones Load Impedance: 32 Ohms 1K Ohm Loudspeaker Nominal Output:72 Db special Length Of Microphone From Mounting Surface:480 Mm (18.9 In) Operating Temperature:0 ºc To +35 ºc Plug And Play Functionality For Ensuring Fast Installation And Reconfiguration Times Immunity To Mobile Phone Interference Functions: Possible-To-Speak Indication Request-To-Speak Indication Built-In Loudspeaker With Volume Control Headphones Socket: Built- In 3.5 Mm (0.14 In) Stereo Headphones Built-In Volume Control For Headphones Color-Coded Led Indicator Above Microphone Button For Showing The Following States: Microphone On, Request-To-Speak, And Possible- To-Speak Similar To Make Bosch Model No. Ccsd-Dl Complete. , Audio Visual Work : Supply Of Control Unit For The Ccs 1000 Digital Discussion:Built-In Mp3 Recorder With Internal Memory And Usb Recordingbuilt-In Digital Acoustic Feedback Suppression (Dafs) For Ensuring Superior Speech Intelligibility Plug-And-Play Functionality For Quick And Easy Connection Of Up To 80 Discussion Devices Native Support For Automatic Hd Camera Control. A Maximum Of Four Microphones Can Be Selected On The Control Unit. This Can Be Further Extended To 10 Microphones In The Web Browser Four Basic Microphonemanagement Mode Shall Be There: -(I) Open: Microphone Button Control With Request-To-Speak (Auto)(Ii) Override: Microphone Button With Override Of Activated(Iii) Voice: Voice Activated Microphones(Iv) Push-To-Talk (Push And Hold Button To Speak) Functions Plug- And-Play Functionality Web Browser Control Open Microphone Control Built-In Mp3 Recorder Discussion Controlsimilar To Make Bosch Model No. Ccsd-Curd Complete. , Audio Visual Work :Supply Of Extension Cable Assy 10M Similar To Make Bosch Model No. Lbb4116/10 Complete. , Audio Visual Work : Column Loudspeaker 30W, Metal, Sound Pressure Level At Rated Power /-1 W (1 Khz, 1 M)-105 / 92 Dbspl, Effective Frequency Range (-10 Db) 153 Hz‒ 17.7 Khz, Horizontal Opening Angle At 1 Khz / 4 Khz (-6 Db)-198°/ 130°,Vertical Opening Angle At 1 Khz / 4 Khz (-6 Db)-62°/ 18°,Rated Input Voltage 100 V, Rated Impedance, Full Power 333 Ω, Half Power 667 Ω, Quarter Power 1333 Ω. Similar To Make Bosch Model No. La2-Um30-D-In Complete. , Audio Visual Work : Booster Amplifier 240 W With Electrical Power Supply Input Voltage 230Vac ±10% At 50/60Hz Or 24Vdc Inrush Current 9A At 230 Vac, 11A At 24 Vdc Performance Rated Output (Rms) 240W Power Reduction On Backup Power -1 Db Frequency Response 60 Hz To 18 Khz (+1 / -3 Db At -10 Db Ref. Rated Output) Distortion 1% At Rated Power,1Khz S/N (Flat At Max Volume) 85 Db Power Consumption Max Power Consumption 760 Va Mains Operation Max Power 451W -3 Db 340W Pilot Tone 55W Idle 16W 24V Dc Operation Max Power 12.1A (290W) -3 Db 11.4A (274W) Pilot Tone 1.7A (41W) Idle 0.3A (7W) Line Input S 2X Connector 3-Pin Xlr, Balanced Sensitivity 1 V Impedance 20K Ohm Cmrr 25 Db (50 Hz To 20 Khz) Gain 40 Db 100 V. Similar To Make Bosch Model No. Lbd1935/00 Complete. , Audio Visual Work : 12-Channel Mixing Console: Max. 6 Mic / 12 Line Inputs (4 Mono +4 Stereo) / 2 Group Buses + 1 Stereo Bus / 2 Aux (Incl. Fx).Similar To Make Yamaha Model No. Mg12xu Complete. , Audio Visual Work : Wireless Handheld Microphone System With Frequency Response 50 To 20,000 Hz, Polar Pattern Unidirectional (Cardioid),Output Impedance @ 1 Khz, Typical-600 Ω,Audio Output Level -43.5 Dbv/Pa, Signal-To-Noise Ratio[1]@ 1 Khz-72 Db, Maximum Spl[1]-1000 Ω Load, @ 3% Thd-139.0 Db, Dynamic Range*1+@ 1 Khz, 1000 Ω Load-117.0 Db, L Equivalent Output Noise[1],Typical, A- Weighted-22 Db, Power Requirements +5V Dc (Nominal), 10 V Maximum. Similar To Make Shure Model No. Svx24/Pg28 Complete. , Audio Visual Work : Wireless Lapel Microphone With Frequency Response 50 To 20,000 Hz, Polar Pattern Unidirectional (Cardioid),Output Impedance@ 1 Khz, Typical-600 Ω, Audio Output Level -43.5 Dbv/Pa, Signal-To- Noise Ratio[1]@ 1 Khz-72 D, Up To 8 Selectable Channels, Up To 4 Compatible Systems, Antenna Switching Diversity, Adjustable Squelch Level, Mic / Line Switch. Similar To Make Shure Model No. Svx14/Cvl Complete. , Audio Visual Work : Hydraulic Pop-Up Box Having Multi-Connectors For Data And Power Connection, Hdmi. Connectors: 2X Power, 1X Rj45 Hdmi, 1X Vga, 1X 3.5Mm Audio Jack 1X Video, Hydraulic (Pneumatic) Open Close Movement , With Bottom Box. Similar To Make maintenance Complete. , Audio Visual Work : Interactive Display Panel:Screen Size-86, Panel Technology-Ips, Back Light Type- Direct, Aspect Ratio- 16:9, Native Resolution-3840X2160 (Uhd), Refresh Rate-60Hz, Brightness-440 Nits, Contrast Ratio- 1,200:1, Dynamic Cr- 5000:1, Color Gamut- Ntsc 72%, Viewing Angle(H X V)- 178 X178, Color Depth- 10Bit, 1.07Billion Colors, Response Time-8Ms (Gto G), Operation Hours (Hours/Day)- 16/7, Surface Treatment (Haze)-28%. Connectivity (Jack Interface):Input- Digital-Hdmi- Es(3), Hdcp2.2, Analog-Rgb, Vga(1), Audio- In, Rs232c In, Rj45(Lan), Usb3.0 Type A(4) , Usb2.0 Type A(1), Usb Type C (1), Audio Out, Touch Usb.Mechanical Specification:Bezel Color-Black, Bezel Width-15/15/15/44Mm, Weight(Head)- 58.6 Kg, Packed Weight- 75.9 Kg, Monitor Dimension(W X H X D)- 60 X 100Mm, Carton Dimensions(W X H X D) (Box Outer Size)- 2110 X 1283X225mm, Handle, Vesatm Standard Mount Interface-800X600. Key Feature:Hw-Wi-Fi, Build-In-Slot Type, Power Indicator, Auto Brightness Sensor, Sw- Webosver, Android- 11.0, Screen Share.Environment Conditions:Operation Temperature-0 °C To 40 °C, Operation Humidity-10% To 90%, Power Supply-Ac 100-240V~, 50/60Hz, Power Type-Built - In Power, Power Consumption- Typ.-385W, Max- 580W,Poweroff- 0.5W, Sound-Speaker-Inbuilt (15Wx2), Certification-Safety-Cb / Nrtl , Emc-Fcc Class A / Ce /Kc, Erp , Ops Type Power Built In Compatible,.Accessory:Power Cord 3 M*1, Usb Cable (Type A-Type B) 5 M*1, Hdmi Cable 3 M*1, Writing Pen*2Pcs, User Manual, Qsg, Carton Box, Remote Controller(Include Battery 2Ea), Wifi Module. Reponse Time-≤5Ms, Accuracy-±1Mm, Interface-Usb2.0, Protection Glass Thickness-3T (Anti-Glare), Operating System Support- Windows 7/8/10/Windows Xp/Linux/Mac/Android (Windowsxp/Linux/Mac Support One Point Touch), Multi Touch Point -Max 40 Points. Android System-Soc-Quad Core A55, Gpu-Mali G52mp2, Ram-4 Gb, Wifi-802.11 A/B/G/N/Ac/Ax (Wifi 6), Lan-Gigabit Lan, Bluetooth-Bluetooth 5.0.Make- Lg/ Samsung/ Panasonic , Audio Visual Work : Led Display Tv:Size-65 Inch, Resolution-3840 X 2160 (Uhd), Backlight Unit Type- Direct, Brightness-400Nit, Dynamic Contrast Ratio (Dynamic Mci (Hz))-1,000,000:1, Static (Panel) Contrast Ratio-1200:1, Refresh Rate-60Hz, Video: Hdr (10 Pro / Hlg)-Yes / Yes, Audio: Speaker (Sound Output)-10W + 10W, Broadcasting System: Digital Terrestrial, Cable, Satellite)-Dvb-T2/C, Hospitality Feature-Hotel Mode / Pdm / Installer Menu,0Ne Channel Map, Ip Channel Manager; External Speaker 0Ut (Int Variable/Fixed, 3.5Mm, Stereo, Single Dedtype (Gnd,L+,R+), 2W+2W With 80), Smart Feature- Web 0S Version (Web0s 6.0), Smart Home (Launcher Bar), Web Browser Pre-Loaded App (Youtube Only, ), Sdp Server Compatibility, Mood Display, Soft Ap, Wifi (Version) (802. 11Ac), Screen Share (Miracast), Smart Share, Bluetooth Audio Playback, Hdmi-Arc (Arc, Hdmi2), Signage Feature- Vertical Setup, Fail 0Ver, Play Via Url, Ntp Server Setting, Cisc0 Certi. Compatibility , Crestron Connected (Network Based Control), Dpm (Digital Power Management), Time Scheduler, Rtc (Real Time Clock), Ntp Sync Timer, Beac0n, Embedded Cm (Contents Manager), Embedded Gm (Group Manager), Supersign Sw C0mpability-Control / Control Plus, Cms(Premium), Simple Editor, Input Interface: Setside - Hdmi In (3 (2.0)), Headphone 0Ut (Phone Jack Type), Rs-232C(D-Sub 9Pin / Phone Jack) (Phone Jack, 4Pi), Jack Interface:Set Rear- Usb (2.0), Rf In, Digital Audio 0Ut (0Ptical), Externalspeaker 0Ut(3.5Mm Phone Jack), Rj45 (Usage Purpose) (Lan),Dimensi0n (Unit: Mm Kg): Vesa Compatible-300X300, Weightwithout Stand-21.5, Weight With Stand-21.8, Weight In Shipping-27.8, Size Without Stand-1454X838x57.7, Size With Stand- 1454 X 899 X 271, Size In Shipping- 1600X970x172, Bezel Width(L/R/U/B): 0N Bezel- 12.8/12.8/12.8/19.9, Power Supply (Voltage, Hz)-Ac 120 V-, 50 / 60 Hz, Power Consumption(Max)-198, Power Consumption(Typ)-169, Standby Power Consumption-Under 0.5W, Safety-Cb, Cu Tr, Emc-Ce, Remote Type-S-Con, Power Cable- Detached (1.5M, Straight Type), Onsite-3 Years.Make- Lg/ Samsung/ Panasonic , Audio Visual Work : Supply, Fitting, Fixing And Installation Of All In One Computer Desktop: Specification: Monitor - 24 Inches, Storage - 1 Tb Ssd, Memory - 16 Gb Ddr5, Processor - Intel Core I5, 14Th Generation, Windows Home, Wifi Inbuilt, Warranty-3Years, Make- Dell/ Hp/ Asus/Lenovo , Audio Visual Work : 4X4 4K Hdmi Matrix Switch Connects Any Of 4 Hdmi Sources To Any Of 4 Hdmi Displays, Supports 4K Resolutions Up To Uhd (3840 X 2160) And Dci (4096 X 2160) With Refresh Rates Of 30 Hz (4:4:4) And 60 Hz (4:2:0), Signaling Rates Up To 3.4 Gbits For Flawless 4K Output, Multiple Control Methods - System Management Via Front- Panel Pushbuttons, Ir Remote And Rs-232 Control. Similar To Make Aten Model No.Vm0404h Complete. , Audio Visual Work : Full Hd Ptz Ip Camera For Video Conferencing Which Supports1080p At 60Fps And Versatile 20X Optical Zoom, Delivers Hd Videooutput Via Ethernet, Hdmi, Usb And 3G-Sdi Simultaneously, Sensor, 1/2.8 2.16 Mp Cmos, Video Format-1080P : 60 / 50 / 30 / 25,720P : 60 / 50 / 30,Video Output (Hd) Interface,3G-Sdi / Hdmi / Ethernet / Usb3.0Optical Zoom,20X,Digital Zoom-12X,Horizontal Viewing Angle-57°,Vertical Viewing Angle-32.1°,Diagonal Viewing Angle-,65.4°, Aperture- F1.6~F3.8, Focal Length 5.33Mm~110Mm,Shutter Speed-1/1 ~ 1/10,000 Sec, Minimum Object Distance, Wide: 0.5M / Tele: 1.5M,Video S / N Ratio 50Db,Minimum Illumination-1.0 Lux (F1.6,50Ire, 30Fps), Focus System-Auto / Manual / Smart Af, Gain Control-Auto / Manual, White Balance-Auto / Manual, Exposure Control-Auto / Manual,Wdr,3D Nr Panning Angle+170° ~ - 170°,Panning Speed-225°/Sec, Tilting Angle+90° ~ -30°,Tilting Speed-225°/Sec. Similar To Make Lumens Model No.Vc-A53complete. , Audio Visual Work : Supply Of Usb &Hdmi Cable For Connectivity. Similar To Make Impression Complete. , Audio Visual Work : Supply Of 15U Rack For Controller & Amplifier. Similar To Make Netrack Complete. , Audio Visual Work : Supply Of 2 Core 1.5 Sq.Mm Flexible Speaker Cable As Per Site With Pvc Pipe. Similar To Make Krystal Complete. , Audio Visual Work : Installation, Testing & Commissioning With Transportation Loading Unloading Labour Charges Of The Entire System As Per Scope Of Work And Direction Of Engineer-In-Charge. , Inverter Air Conditioners Supply, Fitting, Fixing, Installation And Commissioning Of Split Ac Inverter Compressor, Condenser, Supports, With Cordless Remote Controller, Refrigerant Gas, Drain Pump, Etc As Per The Specifications Of The Following Capacities. Inverter 5 Star Rating. Make - Lloyd/ Lg/ Samsung 2.0 Tr 5 Star Inverter Model Split Ac: Specification:Compressor Type-Duo Rotary, Refrigerant-R-32, Power Supply: V-Hz-Ph-230 V~50 Hz 1 Phase, Operating Voltage Range:V-100 V - 300 V, Input Current (100%/50%):A-7.16 A / 4.13 A, Cooling Capacity (100%/50%):W-6340 W / 3170 W, Input Power (100%/50%):W-1630 W / 570 W, Iseer_5.06, Air Flow:M3/H-1270 M3/H, Air Throw Distance:M-12M, Electricity Consumption:Kwh-970.29 Kwh, Idu Noise:Db-43 Db, Odu Noise:Db-57 Db, Area Coverage: Sq. Metre-19.7 M2, Operating Range-Cools At 52 °C. 5 In 1 Convertible (40 / 60 / 80 / 100 / Auto), Smart 4-Way Swing, Turbo Cool, Rapid Cooling (18°C In 45 S), Installation Check, Low Gas Detection, Clean Filter Indication, Wifi Ready (Optional Wifi),Anti-Viral Dust Filter, Pm 2.5 Filter, Golden Fin Evaporator, Hidden Led Display, Stabilizer Free Operation, Strong Dehumidifier, Blow Function, 100% Copper, Eco Friendly Refrigerant(Ü),Idu Dimensions (Lxbxh) As Per Installed Unit:Cm-(116.1 X 24.0 X 34.0) Cm, Idu Dimensions (Lxbxh) As Per Sowm Label:Cm-(116.1 X 34.0 X 24.0) Cm, Idu Packing (Lxbxh):Cm-(127.0 X 41.5 X 33.5) Cm, Idu Net / Gross Weight:Kg-14.2 Kg / 18.0 Kg, Odu Dimensions (Lxbxh):Cm-(94.0 X 37.0 X 68.0) Cm, Odu Packing (Lxbxh):Cm-(102.0 X 45.5 X 74.0) Cm, Odu Net / Gross Weight:Kg-34.6 Kg / 40.4 Kg , Inverter Air Conditioners Supply, Fitting, Fixing, Installation And Commissioning Of Split Ac Inverter Compressor, Condenser, Supports, With Cordless Remote Controller, Refrigerant Gas, Drain Pump, Etc As Per The Specifications Of The Following Capacities. Inverter 5 Star Rating. Make - Lloyd/ Lg/ Samsung 1.0 Tr 5 Star Inverter Model Split Ac: Specification:Compressor Type-Single Rotary, Refrigerant-R-32,Power Supply: V-Hz-Ph-230 V~50 Hz 1 Phase, Operating Voltage Range:V-100 V - 300 V, Input Current (100%/50%):A-3.65 A /1.99 A, Cooling Capacity (100%/50%):W-3500 W / 1750 W, Input Power (100%/50%):W-830 W / 320 W, Iseer-5.2, Air Flow:M3/H-750 M3/H, Air Throw Distance:M-7M, Electricity Consumption:Kwh-520.93 Kwh, Idu Noise:Db-35 Db, Odu Noise:Db-50 Db, Area Coverage: Sq. Metre-11.0 M2, Operating Range-Cools At 52 °C, 5 In 1 Convertible (40 / 60 / 80 / 100 / Auto), Smart 4-Way Swing, Turbo Cool, Rapid Cooling (18°C In 45 S), Installation Check, Low Gas Detection, Clean Filter Indication, Wifi Ready (Optional Wifi),Anti-Viral Dust Filter, Pm 2.5 Filter, Golden Fin Evaporator, Hidden Led Display, Stabilizer Free Operation, Strong Dehumidifier, Blow Function, 100% Copper, Eco Friendly Refrigerant(Ü),Idu Dimensions (Lxbxh) As Per Installed Unit:Cm-(85.6 X 21.9 X 28.5) Cm, Idu Dimensions (Lxbxh) As Per Sowm Label:Cm-(85.6 X 28.5 X 21.9) Cm, Idu Packing (Lxbxh):Cm-(93.4 X 35.5 X 31.1) Cm, Idu Net / Gross Weight:Kg-9.0 Kg / 11.3 Kg, Odu Dimensions (Lxbxh):Cm-(87.0 X 36.5 X 56.0) Cm, Odu Packing (Lxbxh):Cm-(91.0 X 41.5 X 59.0) Cm, Odu Net / Gross Weight:Kg-24.9 Kg / 29.0 Kg. , Installation Of Split Unit : Installation & Commissioning Of Split Air Conditioners Including Inverter Compressor, Condenser, Supports, With Cordless Remote Controller, Etc. , Installation Of Split Unit : Supply, Installation, Commissioning Of Soft Copper Piping (1/4, 1/2 Inch) For Split Units , Clamping, Fittings, Etc. Both The Pipelines Shall Be Insulated With Nitrile Tubular Insulation. , Installation Of Split Unit : Supply, Installation, Commissioning Of 4C X 1.5 Sq. Mm Control Wiring Indoor To Outdoor Unit , Installation Of Split Unit : Supply, Installation, Commissioning Of Pvc Pipes Including All Cost Of Labour, Material, Conveyance, Etc. Complete And As Per The Directions Of Engineer-In-Charge. , Installation Of Split Unit : Supply, Installation, Commissioning Of Pvc Drain Pipes With Supports As Per Drawings And Specifications Of 25Mm Inner Dia Sizes. Including All Cost Of Labour, Material, Conveyance, Etc. Complete And As Per The Directions Of Engineer-In-Charge. , Installation Of Split Unit :Supply, Installation, Commissioning Of Insulation Drain Pipes Including All Cost Of Labour, Material, Conveyance, Etc. Complete And As Per The Directions Of Engineer-In-Charge. , Installation Of Split Unit : Supply, Installation, Commissioning Of Rapping Tape , Installation Of Split Unit : Supply, Installation, Commissioning Of Odu Bracket. , Installation Of Split Unit : Supply, Fitting, Fixing, Installation, & Commissioning Of Outdoor 30 Kva (280V-470V) Un-Balanced Load Three Phase, Air Cooled Servo. Specification: Standard-Iso 9001-2008 Standards, Type-Un-Balanced Type Three Phase Air Cooled, Rating-30 Kva, Input Voltage Range-280V - 470 V, Output Voltage Range-400 Volts±1%, Input Frequency-45-55 Hz, Response Time-10M Sec, Correction Speed-35 To 45 Volt Per Sec, Efficiency-Better Than 98%, Metering / Control-Digital Ac Voltmeter With Output Measure Switch, Ampere Meter For Three Phases, Core Used-Mitor Grade Core For Buck / Boost Transformer, Winding-Electrolytic Copper Grade ( F Class Insulated), Temp. Rise-35˚ C Deg. Cent. Above Ambient, Winding Temp.-Rise 40˚ C Deg., Application-Indoor/Outdoor Type, Transformer Oil-Is 335 Making (Power Oil), Output Accuracy-+/- 1 % From No Load To Full Load, Wave Form Distortion Virtually Nil, Losses At No Load-0.12% Of The Total Capacity, Losses At Full Load-0.7% At Full Load, Terminations-Suitable Bus Bars Will Be Provided In The Termination Box, Operating Temp-0 To 55 Degree Centigrade Along With 2 Nos.. Of Earthing Terminal At Both Side Of Unit And Fabricated Outdoor Stand. Make- Jyoti/V-Guard/Microtek , Installation Of Split Unit : Supply And Laying Of 10Sqrmm Single Core Copper Flexible Wire Along With Proper Safety And Clamping Arrangement. Make- Havells/ Polycab/ Kei , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Supply Of Premix Tea/Coffee Vending Machine: (Multi Option- 3 Nos.. Beverages):Technical Specifications:Supply, Fitting, Fixing, Installation And Commissioning Of Premix Tea/Coffee Vending Machine Of 3 Lane, Net Weight-18.2 Kg, Gross Weight-21.2 Kg, Dimensions (W X D X H)-340 X 485 X 625 Mm, Package Dimensions (W X D X H)-390 X 535 X 695 Mm, 3 Drinks, Gi Body Material, Front Door-Abs Moulded, Power Source-220/110V-1P, Power-1500 Watt., Start-Up Time- Up To 10 Minutes, Dispensing Rate- Up To 22 Cups In One Time Of 100 Ml, Premix Canister-3 Nos.., Water Input-Bubble Top/Pump (Optional), Hot Tank Material-Ss 304, Canister Capacity-1.1 Kg., Auto Flush-Available, Dedicated Hot Water-Yes, - Sensor Operating Range (Only For Touch Less Model Ne/Ap)- 25 Mm (1 Inch).Make - Nescafe/ Godrej/ Nestle , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Installation Charges Of Coffee Vending Machine As Per Direction Of Engineer-In-Charge. , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Ingredients: Bru Coffee Premix , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Ingredients: Nescafe Premix , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Premium Teabags (200S) , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Sugar Sachet (1Kg) , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Lemon Tea Premix , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Disposable Nescafe Paper Cup 110Ml(50Nos.) , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items 3 Supply, Fitting, Fixing And Installation Of Mini Fridge : Specification: 92L Fridge Single Star Energy Rating, Direct Cool Technology And Single-Door Design With A Capacity Of 92 Liters. Its Dimensions Are 45.5 Cm X 49.5 Cm X 84.5 Cm (W X D X H) With A Net Weight Of About 21 Kg, And It Uses R600a Refrigerant With A Fixed-Speed Compressor. It Features Toughened Glass Shelves And An Internal Manual Control Panel. , Chairs: Supply, Fitting, Fixing Of High Back Revolving Chair, Overall Dimension:- 720W ±10 X 720D ±10 X 1290H ±10 Mm, Seat& Back Of Chair Is Made Of 12Mm Hot Pressed Plywood And Connected With Ms Powder Coated L Patta Of Size 65X8mm, Seat & Back Cushioned With Pu Foam In D-45 Kg/M3 & Prime Quality Leatherette Upholstery , Seat Size:- Seat Size:- 540W ±10 X 520D ±10 X 60 Thick. ±5 Mm, Back Size:- 530W ±10 X 730H ±10 X 60Thick. ±5Mm,Mechanism: Torsion Bar Single Point Control, Provides Maximum Adjustability And Scope For Comfort, Seat & Back Moves In Same Direction, Single/ Upright Position Locking, Tilt Tension Knob To Loosen Or Tighten The Tension According To Users Body Weight, Gas Lift:- Lift -Used Gas Lift Of 100Mm Size Of Class-Iv Grade , Plastic Gas Lift Cover, Armrest:- Leatherette Upholstered On Foam Cushioned Armrest Fixed Pp Structure And Ss Frame, Armrest Fixed With Seat & Back Which Gives Comfort & Strength Both To The Chair, Chair Base & Wheels: Metal Chrome Plated Chair Base Frame Made Of 2.5Mm Thick, Base Front Edges Are In Nylon, Base Consists Of 5 Prongs With 650±5 Mm Pitch Circle Diameter, 60Mm Dia. Black Nylon - Twin Wheel Pin Castor. Make- Methodex/ Godrej/ Ayesha , Chairs: Supply, Fitting, Fixing Of Medium Back Revolving Chair, Overall Dimension:- 720W ±10 X 720D ±10 X 1160H ±10 Mm, Seat& Back Of Chair Is Made Of 12Mm Hot Pressed Plywood And Connected With Ms Powder Coated L Patta Of Size 65X8mm, Seat & Back Cushioned With Pu Foam In D-45 Kg/M3 & Prime Quality Leatherette Upholstery , Seat Size:- Seat Size:- 520W ±10 X 510D ±10 X 60 Thick. ±5 Mm , Back Size:- 530W ±10 X H 610 ±10 X 60Thick. ±5Mm,Mechanism: Torsion Bar Single Point Control, Provides Maximum Adjustability And Scope For Comfort, Seat & Back Moves In Same Direction, Single/ Upright Position Locking, Tilt Tension Knob To Loosen Or Tighten The Tension According To Users Body Weight, Gas Lift:- Lift -Used Gas Lift Of 100Mm Size Of Class-Iv Grade , Plastic Gas Lift Cover, Armrest:- Leatherette Upholstered On Foam Cushioned Armrest Fixed Pp Structure And Chrome Plated Frame, Armrest Fixed With Seat & Back Which Gives Comfort & Strength Both To The Chair, Chair Base & Wheels: Metal Chrome Plated Chair Base Frame Made Of 2.5Mm Thick, Base Front Edges Are In Nylon, Base Consists Of 5 Prongs With 650±5 Mm Pitch Circle Diameter, 60Mm Dia. Black Nylon - Twin Wheel Pin Castor. Make- Methodex/ Godrej/ Ayesha , Chairs: Supply Of Signature Fabric Arm Chair. Specification: High-Quality Plastic Construction For Lasting Durability. Ergonomic Design With Cushioned Seat And Backrest. The Glossy Lacquered Finish Resists Uv Rays And Rust. Soft-Feel Fabric Adds A Touch Of Comfort And Beauty. Easy To Clean And Maintain, Suitable For Indoor And Outdoor. Dimensions : Width (Cm) 56, Depth (Cm) 58, Height (Cm) 80, Weight (Kg) 5.2. Make- Nilkamal/ Supreme/ Cello , Induction Stove : Supply, Fitting, Fixing Of 2000W Induction Cooktop.Specification:Induction Cooktop, 2000W, 8 Cooking Options, Overheat Protection, Child Lock Function, Auto Pan Detection & Auto Power Off, Digital Display And Led Indication For Easy Operation, Fixed & Variable Cooking Options With 10 Power Settings (120 W To 2000 W), Dedicated + & - Options To Control Power Levels, Temperature As Well As Time. Make- Havells/ Bajaj/ Prestige , Induction Stove : Supply Of Stainless Steel Drinking Water Bottle, 1.0Ltr. Specification: Drift Stainless Steel Bottle 950 Ml, Size & Dimensions In Cms (L X W X H)-7.5 X 7.5 X 27.5, Size & Weight-950 Ml - 392 G, Cap Type - Screw Cap • With Lid - Yes , Care Instructions - Hand Wash Only, Package Contents - 3 X Drift Stainless Steel Bottle. Make-Milton/Cello/Borosil , Induction Stove : Supply Of Ceramic Snacks Plate Of Size 7 Inches/ 17.8 Cm Make-Milton/Cello/Borosil , Induction Stove : Supply Of Cup With Saucer For Tea/Coffee In Ceramic Make-Milton/Cello/Borosil , Induction Stove : Supply Of Transparent Drinking Water Glass Of 300Ml. Make-Milton/Cello/Borosil , Induction Stove : Supply Of Stainless Steel Snacks Spoon Make-Milton/Cello/Borosil , Induction Stove : Supply & Fixing Of Metal Chrome Finish Plain Pedal Stainless Steel 15L Capacity Dustbin With Lid & Pedal Of Free Size Dimension 30X20x20 Cm. , Induction Stove : Supply And Fixing Of Rectangular Shape Non Slip Foot Mat Of Size 4Ft. X 2Ft. , Induction Stove : Supply And Fixing Of Cotton Luxury Office Chair Towel. , Interior Work : Supply And Installation Of 12.5 Mm Thick Gypsum Glass Fiber Reinforced (Gfr) Pixello 8 / 18 With 8 Mm Circular Diameter & 18 Mm Pitch, Total Open Area 15%, Having Broadband Sound Absorption, With Size Of Boards 1200 X 2400 Mm, Having Density 700 Kg / M³ & Weight 9 Kg / M², With Fire Class 1 & P, Climate 0°C, Rh (50-70), Nrc Up To 0.80, To Be Fixed With Philips Head Screw To Suspended Gi Frames As Per The Specification For Fixing Concealed Grid Ceiling System. The Concealed Wall Paneling System Shall Include Gi Wall Channel (Wc 25) Having Thickness 0.45 Mm, Length 3600 Mm, Unequal Flanges Of 15 & 20 Mm And Web Of 25 Mm, Which Should Be Fixed Along The Perimeters Of The Wall With Nylon Sleeves And Suitable Fasteners At Every 300 Mm Centers. Then Fixed Main Channels (Mc 45) To Be Suspended With The Help Of Gi Channel Sa 25 From Reinforced Cement Concrete / Perling. The Mc 45 Channels Have Thickness 0.9 Mm, Length 3600 Mm, Equal Flanges Of 15 Mm And Web 45 Mm From The Side Wall & Fixed At Every 1200 Mm Centers, With Gi Ceiling Channel (Cc 25) Having Thickness 0.45 Mm, Length 3600 Mm, Knurled Web 35 Mm, Depth Of 25 Mm And Equal Flanges 9.5 Mm, Fastened To The Main Channel In The Direction Perpendicular To The Main Channel At Every 600 Mm Centers. The Framework Will Maintain 50 / 75 Mm Gap From The Walls. Now Lifting The Boards On The cement concrete 25 With The Help Of Screw To Get A Flush Finish. The Jointing & Finishing Of The Same Will Be Done By Using Jointing Compound, Paper Tape. The Synthetic Polyfiber Pf5 X 25 Wool Of 50 Kg Density & Width 600 Mm, 5000 Gsm To Be Laid On The Top Of The Framework / Boards. Make: Anutone / Uno Panel / Techtom. Test Certificate Of The Used Products Shall Be Submitted After Procurement Of Materials. , Interior Work : Supply And Fixing Of 1 Mm (10% +/-) Polymer Based Acoustic Louvers Ceiling Systems Of Pare Innovations Of Panel Sizes Of 265 Mm X 3060 Mm, Along With Option To Custom Size To A Maximum Of 12800 Mm In Length In Approved Shade, Manufactured In India, Made With High Temperature Thermal Transfer Technology, Waterproof, Fire Retardant And Antibacterial. Termite Resistant, Rustproof Material. Panels To Be Installed With Gi Sections Of Suitable Gauge & Size, Subject To Change According To Site Conditions. Panels To Be Installed Using Suitable, Same Shade J-Trim With Dimensions 39 X 20 X 3060 Mm (All In Mm) For Edge Profiles And Connector With Dimensions 76 X 20 X 3060 Mm, Using Same Shade For Connecting Panels, Using Outside Corner With Dimensions 61 X 63 X 3060 Mm, Which Can Be Used In +90 Degree Corners, And Inside Corner Having Dimensions 28 X 76 X 3060 Mm, Which Can Be Used For 90 Degree Corners. Panels Are Maintenance Free And Come With 10 Years Warranty For Colour & Finish Of The Panels, Including Trims Of Pare Innovations. All Material, Accessories, Ancillary Components As Per Recommendation Of Pare Innovations. , Interior Work : Supply And Fixing Of 1 Mm (10% +/-) Polymer Based Acoustic Louvers Wall Panelling Systems Of Pare Innovations Of Panel Sizes Of 265 Mm X 3060 Mm, Along With Option To Custom Size To A Maximum Of 12800 Mm In Length In Approved Shade, Manufactured In India, Made With High Temperature Thermal Transfer Technology, Waterproof, Fire Retardant And Antibacterial. Termite Resistant, Rustproof Material. Panels To Be Installed With Gi Sections Of Suitable Gauge & Size, Subject To Change According To Site Conditions. Panels To Be Installed Using Suitable, Same Shade J Trim With Dimensions 39 X 20 X 3060 Mm (All In Mm) For Edge Profiles And Connector With Dimensions 76 X 20 X 3060 Mm, Using Same Shade For Connecting Panels, Using Outside Corner With Dimensions 61 X 63 X 3060 Mm, Which Can Be Used In +90 Degree Corners, And Inside Corner Having Dimensions 28 X 76 X 3060 Mm, Which Can Be Used For 90 Degree Corners. Panels Are Maintenance Free And Come With 10 Years Warranty For Colour & Finish Of The Panels Including Trims Of Pare Innovations. All Material, Accessories, Ancillary Components As Per Recommendation Of Pare Innovations. , Interior Work : Providing, Fitting & Fixing Of Pre-Moulded Decorative Corner Beading Of Grc, Having Cross Sectional Dimension 112 X 80 Mm And Fixing The Same By Providing Pvc Plug, Screw, Cornice Adhesive, Fevicol Etc., Complete In All Respect As Per Direction Of Engineer-In-Charge. , Interior Work : Supply & Installation Of Wall Panelling Of Anutone Lisoslats Variosurco High Density Fiber Board, Made Out Of Pure Pine Wood Particles, Fr Grade Pure Pine Wood Particle Core With Test Bs 476 Part 5, Melamine Laminated Finish, Perforated Wooden Grooved Hdf Slats L16-2 (2 Mm Grooves @ 8 Mm Centres), Tongue & Groove Edge For A Seamless Look Of Linear Dimension Size 128 / 192 Mm X 2440 Mm X 16 Mm Thick, Having Density 700 Kg / M³, Weight 9 Kgs / M², 2 Mm Front Side Sound Absorber & 1076 Dis Tractor Hole, Non-Woven Acoustic To Be Pasted On Slats. Teak Teca / Beech Haya Surco Is To Be Installed By Using Gi Strut System. The Technical Parameters Are As Follows: Core Variants: Fiber Board Climate (Ocrh): 50-70 Light Reflectance: 75% Green (Rc%): 25 Hygiene (Voc, Clean Room): Low Class: 1 Nrc: 0.85 Strength, Load Capacity (Kg): Anti-Sag, Ball Impact The Concealed Wall Panelling System Shall Include Gi Wall Channel (Wc 25) Having Thickness 0.45 Mm, Length 3600 Mm, Unequal Flanges Of 15 & 20 Mm And Web Of 25 Mm, Which Should Be Fixed Along The Perimeters Of The Wall With Nylon Sleeves And Suitable Fasteners At Every 300 Mm Centres. Then Fixed Main Channels (Mc 45) Having Thickness 0.8 Mm, Length 3600 Mm, Equal Flanges Of 15 Mm And Web 45 Mm From The Side Wall & Fixed At Every 1200 Mm Centres, With Gi Cross Channel (Cc 25) Having Thickness 0.45 Mm, Length 3600 Mm, Knurled Web 35 Mm, Depth Of 25 Mm And Equal Flanges 9.5 Mm, Fastened To The Main Channel In The Direction Perpendicular To The Main Channel At Every 600 Mm Centres. The Framework Will Maintain 50 / 75 Mm Gap From The Walls. Now Clad The Wooden Anutone Slats Surco On The cement concrete 18 With The Help Of Centre & Edge Clips To Get Better Locking Of Slats. The Tongue & Groove Are To Be Properly Aligned To Get A Flush Look. Synth Anutone Poly Fiber Pf5 X 50 Wool Of 500 Gsm To Be Filled Between The Horizontal & Vertical Studs As Infiller With The Help Of Wire / Stick 7 Adhesive. Make: Anutone / Uno Panel / Techtom , Interior Work : Supply & Installation Of Anutone Pine Wood Wool Magnesia Bonded Soak Fabric Cord Binary / Triangle Design Of Selected Colours (Ref. Colour Chart), Kerf Edge Fabric Wrapped, Pine Wood Fibers Panels Of Size 600 X 600 / 1200 X 25 Mm, Having Density 400 Kg / M³, Weight 10 Kg / M², Installed By Using Gi Strut System. The Gi Strut Work Includes Cross Channels cement concrete 50 Having Thickness 0.45 Mm, Length 3600 Mm, Knurled Web 50 Mm, Depth 50 Mm & Base 100 Mm, Equal Flanges Of 13 Mm, Which Is Fastened To Wall Positioned Horizontally In A Regular Manner At 600 Mm Centers. Pvc Vinyl Core Uv Treated H Spline Having Thickness 2 Mm & Length 2400 Mm To Be Fixed, Using Z Bar Or H Spline On The Back Or Edge Of Panels / Tiles & Similar On The Back Of Channels Perpendicular To The Cross Channels cement concrete 50 At 600 Mm Centers. Kerfed Edge Fabric Wrapped Factory Panels Shall Then Be Inserted Into The H Spline Against The Wall To Perfect Fit. Panels Shall Be Back Lined With Acoustical Infill Of Anutone Synth Pf5 X 50 Mm Thick, Adhered To The Wall Using Stick 7 Adhesive. The Technical Parameters Are As Follows: Core Variant: Pine Wood Fibers Fire Class: 1 & P Acoustic - Nrc 20 Mm C10: 0.85 Climate: 0°C, Rh 50-90 Termite Resistance: Yes Light Reflectance: Colour Dependent Green Rc%: 10 Hygiene (Voc, Clean Room): Low Strength, Load Capacity (Kg), Ball Impact Make: Anutone / Uno Panel / Techtom. Test Certificate Of The Used Products Shall Be Submitted After Procurement Of Materials. , Interior Work : Supply And Installation Of 20 Mm Thick Pine Wood Wool Magnesia Bonded Colour Tiles / Panel Having Size 600 X 2400 / 1200 Mm, Having Density 400 Kg / M³ & Weight 8 Kg / M², With Fire Class 1 & P, Climate 0°C, Rh (50, 90), Nrc - 0.97 & Green (Voc, Rc%) Low, 10 To Be Fixed With Philips Head Screw By Using Concealed Ceiling System. The Concealed Ceiling System Shall Include Gi Wall Channel (Wc 25) Having Thickness 0.45 Mm, Length 3600 Mm, Unequal Flanges Of 15 & 20 Mm And Web Of 22 Mm, Which Should Be Fixed Along The Perimeters Of The Wall With Nylon Sleeves And Suitable Fasteners At Every 300 Mm Centers. Then Suspend Main Channels (Mc 45) Having Thickness 0.9 Mm, Length 3600 Mm, Equal Flanges Of 15 Mm And Web 45 Mm From The Soffit At Every 1200 Mm Centers With Suspender Angle (Sa 25) Having Thickness 0.45 Mm, Unequal Flanges Of 25 & 10 Mm. Gi Ceiling Channel (Cc 25) Having Thickness 0.45 Mm, Length 3600 Mm, Knurled Web 35 Mm, Depth Of 25 Mm And Equal Flanges 9.5 Mm, Is Fastened To The Main Channel In The Direction Perpendicular To The Main Channel At Every 600 Mm Centers. Now The Jointing & Finishing Of The Same Will Be Done By Using Sealant To Look Flush. Now, 20 Mm Strand Square Edge Of Size 600 X 2400 X 15 Mm Thick Shall Be Fixed. Apply Synthetic Poly Fiber Pf5 X 10 Acoustic Wool Of 50 Kg Density To Be Kept On The Top Of The Ceiling By Laying On The Framework. Make: Anutone / Uno Panel / Techtom. Test Certificate Of The Used Products Shall Be Submitted After Procurement Of Materials. , Interior Work : Supply And Installation Of Broadloom Carpet In Roll Form Of Approved Make, Shade & Pattern For Conference Hall. Carpet Shall Be Of Loop Pile, Of Size 500 Mm X 500 Mm, Having Pile Yarn Or Equivalent Material, Having Minimum Pile Height Of 2.9 Mm And Maximum Total Height Of 9 Mm With Backing Of 6 Mm Thick Open Cell Pu Foam. Carpets Shall Have Inbuilt Soil Protection, Fire Resistance And Antistatic Properties. Carpets Used Shall Also Be Certified From Leed / Griha, Certified With A Test For Indoor Hygiene Properties. , Interior Work : Supplying And Fixing Murals With Frame Of Natural Fibre/Putty Of Approved Size Including Cost Of All Materials, Labour, T&P Etc Required To Complete The Work As Per Drawing, Design And Direction Of Engineer-In-Charge. , Interior Work : Manufacture, Supply And Installation Of Noise (Stc 45) Fire Rated Acoustical Doors Of Size 1200 X 2100 Mm (Main Auditorium Doors). Framework Consists Of Wooden Sections Of Size 150 Mm X 75 Mm (Nominal Finished Frame Section Of 143 Mm X 65 Mm) With Self-Adhesive Type Perimeter Seals On The Perimeters Of The Frame And The Shutter Edges (Note: Shutter Is Double Edged). Fixing Arrangements Shall Be By Means Of 4 Nos.. Of G.I. Holdfast 225 Mm X 20 Mm X 4 Mm With Split End On Either Side Of The Wall, Including 8 Nos.. Of Stainless Steel Ball Bearing Hinges Of Ss 304 Quality Of Size 102 Mm X 102 Mm X 3 Mm Thick, Capable Of Taking Load Up To 120 Kg Of The Shutter, With Ss Pin, Lock Strike Plate, Shock Absorbers As Specified. 60 Mm Thick Double Leaf Shutter Of Appropriate Size Made Out Of Perimeter Railing Of Seasoned Red Marenti Hardwood (Moisture Content Limited To 18%) Of Size 100 Mm X 30 Mm And 2 Nos.. Of 6 Mm Thick Promina-60 Board, Lined With Sound Deadener (Sound Deadening Membrane 4 Mm Thick) Sandwiched Between 2 Boards On Each Side Of The Shutter Framework Using Suitable Fasteners And Duly Hot Pressed With 3 Mm Commercial / Marine Ply To Get The Required Surface For Laminate / Veneer / Paints. Cavity Is Filled With 96 Density X 50 Mm Thick Rock Wool. Doors Shall Be Provided With Acoustical Perimeter, Centre & Drop Down Seals. Make: Stairwell Studio, Tesco, Signum Doors. , Interior Work : Supplying, Fitting And Fixing In Position 32 Mm Thick Flush Door With Teak Wood Beading And 1 Mm Thick Sunmica To Both Sides Pasted With Adhesive, Including Fixing Of Fixtures Like Godrej Make Mortice Lock Having Model No. 9168, Godrej Make Door Closer Having Model No. 8340, 100 Mm Aluminium Hinges, Handle, Tower Bolt, Stopper, Including Cost Of All Materials, Labour, All Taxes, Transportation, Loading & Unloading Etc., Complete As Per Specification And Direction Of The Engineer-In-Charge. , Interior Work : Providing And Putting In Position Column / Wall Panelling As Per Approved Drawing, Made Out Of 12 Mm Thick Bwr Ply Over Framing With 1 Mm Thick Approved Colour Laminate, Including Cost Of All Materials, Labour, T & P Etc. Required For The Work, Complete In All Respect As Per The Direction Of The Engineer-In-Charge. , Interior Work : Providing And Fixing Wooden Venetian Blinds With Pelmet Of Vista Brand As Per The Approved Shade And Design, Along With All The Accessories Including Cost, Conveyance, Loading, Unloading, Taxes Of All Materials, Cost Of All Labour, Sundries And T & P Etc. Required For The Work, Complete As Per Specification And Direction Of The Engineer-In-Charge. , Interior Work : Supplying And Fixing Of Conference Table Of Size 40-0 X 8-0 X 2-6 (Veneer Finish), Made Out Of Calibrated Bwp Plywood With Approved Shade Of 1 Mm Thick Flitches Veneer. It Should Be Provided With Leg Structure Made Out Of 25 Mm Thick Ply & 32 Mm Ply Finished With Veneer For The Top. It Should Have Provision For Necessary Power (Pop-Up Box). All Exposed Edges Should Be Mechanically Edge Banded By Matching 1 Mm Thick Veneer Edge Banding With Hot Melt Glue (Jowat / Henkel). All Pressing Veneer Onto The Ply Has To Be Executed Mechanically By Hot Press And Polymerised D3 Adhesive (Kleiberit / Jowat / Henkel). The Non-Exposed Area Will Be Covered Up By 0.8 Mm Balancer Laminate. The Same Furniture Will Be Finished With Two Coats Of Sealer Followed By One Top Coat In Pu. The Pu Lacquer To Be From Sirca / Teknovance (Italy). It Should Have A Knock Down Arrangement Of Fitting. All Hardware Fittings Will Be Hettich / Hafele / Blum Make. Make By Vibe. , Interior Work : Supplying And Fixing Of Stage Table Of Size 12-0 X 2-0 X 2-6, Top Made Out Of 25 Mm Calibrated Bwp Plywood With Approved Shade Of 1 Mm Thick Flitches Veneer, Having Side Panel Continuing Up To The Floor Connected By A 16 Mm Modesty Panel. It Should Be Provided With Leg Structure Made Out Of 25 Mm Thick Ply & 32 Mm Ply Finished With Veneer For The Top. All Exposed Edges Should Be Mechanically Edge Banded By Matching 1 Mm Thick Veneer Edge Banding With Hot Melt Glue (Jowat / Henkel). All Pressing Veneer Onto The Ply Has To Be Executed Mechanically By Hot Press And Polymerised D3 Adhesive (Kleiberit / Jowat / Henkel). The Non-Exposed Area Will Be Covered Up By 0.8 Mm Balancer Laminate. The Same Furniture Will Be Finished With Two Coats Of Sealer Followed By One Top Coat In Pu. The Pu Lacquer To Be From Sirca / Teknovance (Italy). It Should Have A Knock Down Arrangement Of Fitting. All Hardware Fittings Will Be Hettich / Hafele / Blum. Make By Vibe By Transform Furnitures Pvt. , Interior Work : Providing And Fixing Wooden Podium Of Size 19-0X10-0X0-6Including Cost Of All Materials, Labours, T&P Etc Complete As Per Direction Of Engineer-In-Charge. , Interior Work : Supplying All Materials, Labour, T & P And Providing And Fixing In Position M.S. Panelled Door (Double). Supplying & Fixing Of Pantry Unit Made Out Of 16 Mm Calibrated Bwp Plywood With Approved Shade Of Laminate, With Exposed Side & Inside 0.8 Mm Balancer Laminate. All Laminates Have To Be Hot Pressed With D3 Glue (Jowat / Henkel / Kleiberit Glue). The Said Storage Should Have Two Side Panels & A Bottom Panel. The Top Will Be Moulded Granite Top. It Should Be Provided With A Back Panel Made Out Of 6 Mm Thickness. The Cabinet Should Be Provided With Two Openable Shutters Mounted With The Cabinet By Full Overlay Hinges. The Shutter Has To Be Laminated With 1 Mm Thick Lamination Hot Pressed Onto It. All Exposed Edges Should Be Mechanically Edge Banded With Pvc Edge Banded Tape (Rehau / Dolkan) Using Hot Melt Glue. It Should Have A Knock Down Arrangement Of Fitting. All Boring Has To Be Done On Cnc For Precision Of Fitting. The Hardware Will Be Of Hettich / Olive Make. The Carcass Will Be Provided With Suede Finished Edge Banded Shutters. All Accessories Are In Ss, Make By Vibe By Transform Furnitures Pvt. Ltd. , Interior Work : Providing And Painting Two Coats With Plastic Emulsion Paint Over A Coat Of Primer Of Approved Quality And Approved Shade In All Floors At All Height By Making The Surface To The Interior Plastered Surface Of Walls Smooth, Including Cost, Conveyance, Loading And Unloading And Taxes Of All Materials, Cost Of All Labour, Sundries, T & P, Scaffolding Etc. Required For The Work And Complete In All Respect As Directed By The Engineer In Charge. , Interior Work : Providing And Fixing Glass Reinforced Concrete (G.R.C) Screens In Approved Size, Pattern, Design, Shade And Thickness Of 50 Mm On Frame And Design Element In 30 Mm Thick, Having Weight Approximately Between 3.5-4 Kg Per Sq. Ft. The Above Weight And Thickness Is Considering Dimensions Of Screens Up To 2133 Mm In Height And 1219 Mm In Width And Having At Least 50% Void Space. The Screens Should Be Made From ‘53 Grade White Portland Cement Manufactured By ‘Jk Cement Or Equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber Manufactured By ‘N.E.G Japan Or Equivalent, Super Plasticizers Manufactured By ‘Basf Or Equivalent, Polymers Manufactured By ‘Basf Or Equivalent, And U.V Resistant Synthetic Inorganic Pigments Should Be Used For Pigmentation Manufactured By ‘Bayferrox (Germany) Or Equivalent. The Material Castings Should Take Place In Frp Molds. The Fixing Of Screens Should Be ‘Dry Fixing, I.E., To Be Done With M.S. Galvanized Clamps, Fixtures And Fasteners Of The Shutter Frame. , Interior Work : Signage With Letter Writing Of Brass Finish Of Approved Size As Per Direction Of Engineer In Charge
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
34.
Defence #9929205 AOC
Tender For Augmentation Of Power Supply At Naval Area Visakhapatnam.; 1 Schedule A Part – I to Schedule A Part – VII:NOTE: Schedule A Part – I to Part –VII are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only 2 Lumpsum price worked out by the contractor for BUILDINGS & STRUCTURES,as listed in Schedule A Part – I 3 Lumpsum price worked out by the contractor for SITE CLEARANCE / AREA DEVELOPMENT/EARTH WORK/EXCAVATION,as listed in Schedule A Part – II 4 Lumpsum price worked out by the contractor for INTERNAL ELECTRIFICATION, as listed in Schedule A Part – III 5 Lumpsum price worked out by the contractor for INTERNAL WATER SUPPLY, as listed in Schedule A Part – IV 6 Lumpsum price worked out by the contractor for SEWAGE DISPOSAL,as listed in Schedule A Part – V 7 Lumpsum price worked out by the contractor for EXTERNAL ELECTRIFICATION, as listed in Schedule A Part – VI 8 Lumpsum price worked out by the contractor for LIGHTENING PROTECTION ,as listed in Schedule A Part – VII 9 Schedule A Part - VIII: (Miscellaneous Items) ( Internal Electrification, Internal water supply, External Electrification, Site clearance & Area development, Lightening Protection and AC & Ref) 10 Internal Electrification 11 M&L for Ponit wiring with 1.5 sqmmPVC insulated and unsheathed copper conductorcable multistranded 1100 Volts grade, FRLS, ISI marked drawn through and inculding non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marked, concealed to wall or surface mounted on pillars/columns including provn of box type switchboard consisting of pre fabricated pressed steel terminal box of suitable size made out of 1.2 mm thick sheets,for mounting modular brackets,with and including modular brackets and switch plates as required at site for fixing modular type switches, sockets etc inculding one run of 1.5 sqmm PVC insulated unsheathed copper cable for earth continuity green in colour, connected to earth duly complete all as specified and directed forOne light/ exhaust fan/ fanpoint controlled by one switch :-Note: (a) The PVC conduit shall be concealed and switch boards shall be flush to wall. (b) On columns/ pillars the box type switchboards surface mounted with necessary PVC conduit upto ceiling/nearest junction tapping shall be surface type conduitand quoted rate deemed to be inclusive for the same.(c) The quoted rate inclsuive necessary modules any type as per requirement incl all accessories complete 12 All as per item No. 10 abovebut one light point controlled by two Nos of two way switch complete all as specefied and directed. 13 All as per item No.10 above but One3 pin socket outlet 05 amps socket on independent board with 1.5 sqmm FRLS PVC wire for phase and neutral and one run of 1.5 sqmm copper cable green in colourfor earth continuty conductor complete all as specefied and directed. 14 All as per item No.10 above but One3 pin socket outlet 15 amps socket on independent board with 2.5 sqmm FRLS PVC wire for phase and neutral and one run of 2.5 sqmm copper cable green in colourfor earth continuty conductor complete all as specefied and directed. 15 All as per item No. 10 above but for one geycer/AC point with 4.0 sqmm FRLS PVC wire for phase and neutral and one run of 4 sqmm copper cable green in colourfor earth continuty conductor complete all as specefied and directed. 16 S&Fexhaust fan, steel body AC single Phase. 230 V of size 450mm sweep with, blades, and frame and louvers fixed on wall making opening, fixing and making good the distrubed surfaces etccomplete with and inclussive of making necessary electric connection from ceiling rose to fan through 1 sqmm twin core flexible wire all as spcified and as directed. 17 S&FLED tube light fitting, batten type,poly carbonate body, 20Watt fitting with all accessories, internally prewired and connecting up with with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. 18 S&FLED light fitting, batten type,suspended LED aluminium profile lights cool white 36 watt length 1200mm including all connections, hanging strings complete all as specified and directed. 19 S&FLED bay light fitting 70 Watt 230V AC indoor type with thermal management in multiple optics and industrial type and corrosion resistant complete with driver and lamp complete all as specified and directed. 20 S&FLED flood light fitting 210 Watt 230V AC out door type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. 21 S&F LED bldg Security light fitting 35 Watt, 230AC out door type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 ptoction complete all accessories including 1.5sqmm weather proof 3 core FRLS grade copper conductor to fitting including 32mm dia medium grade1.5 m long GI pipe for fixing of street lights, bend to shape for fixing on wall/pole withsuitable MS brackets nuts and bolts etccompelte all as specified and as directred. 22 M&L for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall/roof, and PVC wire of size 2x2.5 sqmm for phase and neutral duly colour coded and 1x2.5 sqmm for earth continuity conductor green in colour complete all as specified and as directed.( for SPN DB to board and submain wiring of building security light)Note :(i) Two run of 2.5 Sqmm + one run of 2.5 Sqmm as a earth wire cable + one run of PVC conduitshall be measured as an one Unit. 23 M&L for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall/roof, and PVC wire of size 2x4 sqmm for phase and neutral duly colour coded and 1x4 sqmm for earth continuity conductor green in colour complete all as specified and as directed.Note :(i) Two run of 4 Sqmm + one run of 4 Sqmm as a earth wire cable + one run of PVC conduitshall be measured as an one Unit. 24 M&L for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall/roof, and PVC wire of size 4x10 sqmm for phase and neutral duly colour coded and 1x10 sqmm for earth continuity conductor green in colour complete all as specified and as directed.Note :(i) four run of 10 Sqmm + one run of 10 Sqmm as a earth wire cable + one run of PVC conduitshall be measured as an one Unit. 25 S&F VTPN MCCB DB 4 way 12 outgoing having powder coated sheet steel enclosure fitted with bus bar, DIN channel & neutral link & earth link complete all as specefied and directed. 26 S&F TPN DB 4 way 12 outgoing having powder coated sheet steel enclosure double door fitted with bus bar, DIN channel & neutral link & earth link complete all as specefied and directed. 27 M&L for earthing complete with GI steel plate electrode 600x600x6 mm, burried directly in ground (earth pit not less than 2.25 m deep below ground level)with top edge of the plate not less than 1.5 m below normal groundlevel, connected to GI wire 4 mm dia (upto 7.5M in length from earth plate) by means of bolts, nuts, check nuts and washers of GI all as shown in electrical plate No-3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipelight grade for watering pipe and 32 mm bore GI light grade for earth lead protection pipe connected upto DBs, and suitable CI top cover with handle, funnel, strainer,charcoal, salt and testing on completion all as specified and directed. Note- Rate quoted deemed to be include excavation and earth work in any type of soil with PCC workcomplete all as specefied and directed.Note: GI earth wire upto 7.5 m shall be deemed to be included in the quoted lumpsum and beyond 7.5 m shall be measured and paid separately under relavent item. 28 Internal Water Supply 29 S&F Bib taps two way, cast copper alloy fancy typechromium plated with crutch or butterfly handle, screwed down for size of15 mm inner dia, suitable fo 16 mm outer dia CPVC pipes complete all as specified and as directed. Make:- Jaquar cat No. OPP-15041PM or equivalent 30 SITE CLEARANCE / AREA DEVELOPMENT/EARTH WORK/EXCAVATION 31 M&L for cleaning jungle incl uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm and removal of rubbish upto a distance of 50 m outside the pheiphery of the area cleared all as specified and as directed. 32 External Electrification 33 Supply, Installation, Testing and Commissioning of Copper wound Power transformer step down outdoor type 132/33 KV, capacity16 MVA(suitable for 10/16MVA cooling), ONAN/ONAF, Vector group Star/star (YNyn0) with on load tap changing gear (+) 5% to (-)15% in steps of 1.25% on HV side, with terminal arrangement of HV Outdoor Bushings/LV Bushing and all standard accessories as per IS 2026 and as specified in PS, including first fill of oil complete comprising the following accessories:-a)Conservator Tankb) Pressure Relief Devicec) Buchholz Relay & Oil Surge Relayd) NCT on EHV and HV sidee) Oil Temperature Indicator (OTI)f) Winding Temperature Indicator (WTI)g) Oil Sealingh) Breatherj) Aircell in conservator tankk) Radiators and control valvesl) Each radiator tank shall have its own cooling fans, shut off valves at the top and bottomm) motor operated OLTC shall be n) On load tap changing with RTCC panelo) Marshalling boxp) Thermosphyn filter 34 q) Terminal Connectorsr) Direct solid earthing both HV side and LV sides) Name Plate (Rating, Diagram and Valve Plates)t) Metallic enclosed NGR as per OEMu) NIFPS to be installed by OEMTransformer rating plate shall contain the information as given in IS-2026 (Part-I).Makes: Bharat Bijlee/Crompton Greaves / Schneider / Siemens 35 Note : a) PCC foundation and mounting rails, all civil work, etc and general works which are required as per site/technically required to achieve optimum efficency of the transformer are to be supplied by the contractor for which rate is deemed to be included in the unit rate quoted.b)Size of plinth, PCC, Rail size etc shall be as per OEM recommendation.c) Technical drgs of the transformer alongwith NIFPS submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the Transformer to be inspected by the rep of accepting officer at various stages at Factory premises as per IS before despatch.d) pre-commissioning inspection of Transformer shall be carried out by Senior Electrical Inspector / Electrical Inspector.e) Manufacturer shall possess NABL accredited test lab for electrical testing(Routine test, type test and special test) 36 f)Full Type Test Reports of at least the followings must be submitted: -1. 132/33 kV Power Transformer for same capacity or higher2. Tap Changer3. Buchholz Relay4. Pressure Relief valve5. Oil Surge Relay6. Temperature rise test7. Impulse test 8. Load and No load loss 37 Supply, install, test and commission lightning arrestor single pole made of polymer , heavy duty station class, gapless, zinc oxide type (non linear) fitted with pressure relief device, arc diverting ports, grading/corona rings, discharge counter with ammeter, mounting insulator complete all as specified and as per IS 3070 (Part I) and with following parameters:- Nominal system voltage : 132 KVNormal discharge current rating : 10 KA .Note- The cost of Galvanised Iron lattice structure including foundation (as Per OEM) is deemed to be included in the Quoted rate 38 Supply, Installation, Testing and Commissioning of cable XLPE insulated, armoured, 132 KV grade (E) copper conductor UG cable, laid in trenches/on structures/in cable duct horizontally or in tier formation as per site condition complete all as per IS specifications of size. 1 C x 630 sqmm. The cable shall be of EHV grade single core, armoured stranded compacted circular Copper conductor of cross section 630 sq.mm, core screening by a layer of semiconducting tape followed by a layer of semiconducting compound, cross linked polyethylene (XLPE) dry cured insulation, insulation screening with semiconducting compound extruded directly over the insulation, longitudinal sealing by a layer of non woven tape with water swellable absorbent over insulation screen, followed by radial sealing of corrugated & seamless or seam welded aluminum with asphalt coating & overall PE sheathed & graphite coated/semi conducting layer and conforming to the technical particulars of specification.IS 7098 part 3 shall be followed for manufacturing of cable along with technical specification. Makes: Universal/ KEI /RPG/CCI.Note- Technical details of the cable submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the cable to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. 39 Supply, lay, connect, test and commission multi core copper conductor cables, PVC insulated, LT 1100 volts grade GI strip/wire armoured in ducts/on structuresincluding clamps, terminations on both ends with glands and connecting up to the equipment all as specified and of following sizes:- 40 4 core 1.5 sqmm 41 4 core 2.5 sqmm 42 6 core 2.5 sqmm 43 6 core 4 sqmm 44 Supply and fix GI cable tray perforated on walls/MS angle iron supportsof depth 100mm following widths including bends, coupler plates complete all as specified.Note: Angle iron used for fixing cable trays will be measued and paid separately. 45 200 mm width 46 300 mm width 47 Material and labour for provision of earthmat laid in trenches/ ducts/ walls made of following sizes of GI strips including jointing by means of brazing complete all as specified :- 48 GI 100 x 10 mm 49 GI 75 x 10 mm 50 GI 50 x 6 mm 51 GI 32 x 6 mm 52 Supply and fix earth strip following sizes laid in trench/ floor/ walls including jointing by means of brazing complete all as specified :- 53 100 x 10 mm copper strip 54 50 x 6 mm copper strip 55 32 x 6 mm copper strip 56 Supply, installing, testing and commissioning of CPRI approved LT panel board, cubical indoor type, fabricated out of 2.00 mm thick CRCA sheet with angle iron frame made of 50 x 50 x 6mm at vertical corners & medium channel at base of panel board floor mounted, dust and vermin proof, with busbar 200 Amps suitable for voltage 415 V 3 phase 4 wire weather proof, with separate hinge door for each compartment with locking arrangement, with back door common openable (screwed), groutedin PCC 1:2:4 complete incl painting the steel surfaces with two coats of zinc chromate primer & two coats of epxoy paint suitable for installation in coastal areas and incl of suitable size aluminium busbar (TPN), suitable cable glands, LED Indicating lamps and incl provn of the following:- 57 (i) 4 Pole MCCB 25 KA 100 A - 1 Nos (I/C)(ii) 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA - 03 No (iii) 4 Pole MCCB 40 Amp, 50 Hz, 415 V with rupturing capacity 25 KA - 02 No (iv) 4 Pole MCCB 25Amp, 50 Hz, 415 V with rupturing capacity 25 KA - 02 No (v) Digital voltmeter with selector switch - 1 No (vi) Digital ammeter with CTs & selector switch - 1 No (vii) LED indicating lamps - 8 sets (3 lamps/set) 58 Supply and lay in trenches HDPE pipe Double wall corrugated 200 mm dia with integral socketsfor cable protection including necessary collars, earth work and sealing at both ends with bitumen compound complete all as specified. 59 Supply, lay, connect, test and commission cable LT 1100 volts heavy duty XLPE insulated armoured aluminium conductors, in trenches/ ducts on angle iron supports including glanding, crimping and connecting up complete all as specified and of following sizes:- 60 3.5 Core x 95 sqmm 61 4 Core x 25 sqmm 62 Supply, Installation, Testing and Commissioning Earthing complete with Galvanised Iron plate electrode 600x600x6 mm thick buried directly in ground(earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to GI earth strip 32 x 6 mm by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 3 of SSR part I including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel with 15 mm dia medium grade for watering and for protection of earth electrode 40 mm dia light grade GI pipe all as specified and directed and tested on completion. 63 Supply, Installation, Testing and Commissioning Earthing complete with copper earth plate electrode 600x600x3 mm thick buried directly in ground(earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to copper earth strip 25 x 3 mm by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 3 of SSR part I including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel with 15 mm dia medium grade for watering and for protection of earth electrode 32 mm dia light grade GI pipe all as specified and directed and tested on completion. 64 Boring of holes under road, pavement, hard standing by trenches by trenchless technologyas per site conditions using ultra sound technique and necessary machinery complete all as specified 65 depth of trench varying between 2 to 4 meters 66 depth of trench varying between 4 to 7 meters 67 Supply, Installation, Testing and commissioning ofindoor, metal enclosed corrosion proof aluminium alloy gas insulated switchgear 145 KV 3Phase 50 HZ, 2500 Amps, Three phase encapsulated consisting of2 nos outgoing transformer bay in either side of the existing GIS (Siemens) including installation tools, spares, refill kits all as specified. Makes: ABB/CG/GE/SIEMENS 68 Each Transformer feeder bay consists of the following: 2Nosa) Circuit breaker SF6 insulated 145 KV 2500 A 3 pole with short circuit current with stand capacity of 40 KA for 3 sec - 1 No.b) Disconnector cum earthing switch SF6 insulated, 145 KV 2500 A 3 pole motor operated - 2 sets.1 set on Bus side and 1 set on line side.c) Fast acting earth switch SF6 insulated 145 KV motor operated - 1 sets. d) Current transformer 145 KV 300-150/5+5+5 with Core 1:class 0.2, 15 VA , Core 2 : 5P20, Core 3 : PS class, 15 VA respectively - 1 Set (Three Nos).e) Three phase Voltage transformer 0.2 class accuracy, 10 VA burden,145 KV, 132 KV/√3/110V/√3 - 1 set.f) Lightning arrestor gapless type metal zinc oxide type 120 KV rms 10 KA including discharge counter and leakage current meter.g) Bus bars 145 KV 2500 Amps 3Ø - required as per scheme.h) Cable end box suitable for 132 KV system - 1 No.j) Local control panel- 1 No. 69 Note : The GIS system offered by the bidder shall be designed, manufactured, assembled and tested in accordance with the IEC 62271-203 for switch gear and other relevant IEC andfor balance materials as mentioned in PS. The GIS Outgoing bays are to be installed with the existing GIS extension (Siemens Make ) interface in either sides of the setup. Bidder has to supply the following items along with GIS system and costis deemed to be included in GIS system. Civil foundation / mounting rails, all civil work, etc and general works which if required as per site/technically required to achieve optimum efficency are to be supplied by the contractor for which rate is deemed to be included in the unit rate quoted. Erection & commissioing shall be under OEM recommendation and supervision. The earth connection from GIS euipment to earth grid/matt as per OEM recomendation and the cost of same is deemed to be included in the unit price. Technical drgs of the GIS module submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the GIS module to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of GIS module shall be carried out by Senior Electrical Inspector / Electrical Inspector. 70 a) Local control cubicles.b) Gas handling equipment for draining and refilling of each compartment of GIS including filtration and purification equipment and vacuum pump. c) SF6 gas sufficient for first filling of entire switch gear including usual losses during commissioning.d)1 Bottles (40 Kg each) of SF6 gas in non returnable vessels. e)Gas leakage detectors.f) Gas Purity Tester for air content and moisture content in SF6 gas. g)Special tool and tackles for erection operation and maintenance of GIS h)Mandatory spares and tools ( Aux contact ( for CB, Busbar disconnector), Motor for CB drive (DS-ES drive), Bursting Disc, Adsorber, Density Monitor for CB, Tripping coil, Closing Coil. - 01 set Each.(i) Bay control unit. 71 Supply, Installation, Testing and Commissioning of control and relay simplex type panel with front swing & front perplex glass door RAL7035 natural IP 32 ventilation for 132/33 KV transformers protection consisting of the following: 72 a) Numerical Transformer Differential Protection Relay Make- ABB/Siemens – 1nob) Numerical Backup Protection Relay of Make - ABB/Siemens – 1noc) Tri Vector Meter - Secure make Premier 300 or Equivalent- with ABT & RS485 (modbus) port, RJ 45 port Accuracy class 0.2S- 2nod) Auxiliary Relay - with self-reset contacts. Operating time<20ms. (4 Contacts) of Make ABB/Siemens – 5nose) DC/ACSupply Supervision-200ms 73 Supply, Installation, Testing and Commissioning of 145KV 630A 40KAOil filled outdoor termination with composite insulator, solid rod connector bolt and support insulators for cables with XLPE insulation. The termination base plate and the cables metallic sheath shall be electrically insulated from the supporting structure by means of self-supporting stand-off insulators or any other self-supporting means designed to withstand both mechanical and electrical stresses in services. The stress cone shall inhibit possible mechanical stress and deformation of the cable insulation surface during operation and also shall be capable of accommodating minor radial and longitudinal movement without determent to the dielectric stress in the insulation shield. The termination shall be within polymeric or porcelain hollow insulator in brown or grey colour as perstandard practice of manufacturing in addition upon, arcing horn and shield ring shall have to be supplied wherever required. The termination shall be filled with an insulating compound up to a level where the electric field is substantially reduced and shall be offered. Oil filled termination should have silicon oil as di-electric medium. Silicon oil should not be subject to any heating at site prior to filling. The outdoor terminal should be suitable for very heavily polluted atmospheric conditions with total creepage distance of 31 mm/ kV and protected creepage distance of not more than 50% of the total Creepage distance. The cable end terminals for terminating the cables shall be fully compatible with the cables to be supplied. Civil foundation / Supporting Strcuture etc and general works which are required as per site/technically required to achieve optimum efficency are to be supplied by the contractor for which rate is deemed to be included in the unit rate quoted. 74 Supply, Installation, Testing and Commissioning of 145kV Dry type GIS termination suitable for XLPE 132 KV IC x 630 sqmm including necessary accessories , fixtures and fittings of complete installation etc complete all a specified and directed.Indoor Termination at GIS SF6 Housing It shall be dry type without insulating oil. There shall be mechanical devices to maintain the interface pressure if requires. It shall be based on the EPR (Ethylene-Propylene Rubber)- based or silicon based stress relief cone. Termination shall be dry type without insulating oil. Stress relief cone and mechanical devices shall be designed to fit with controlled interference over the cable insulation and shall follow the cables diameter variations still guaranteeing under any service condition a sufficient positive pressure to control the electric field concentration. Plug-in type leading conductors shall be supplied though at the time of detailed engineering confirmation shall be given for selection of normal type, blind type or plug-in type. Design and scope of delivery shall be fully complying with IEC-60859, IEC-62271-209 and possibly adjusted the various needs of project. The main insulation components shall be fully examined and tested in the factory.For cable Termination purpose only certified (certification from cable accessories manufacturer ) personnel shall be employed. Make: Raychem or Equivalent 75 Supply, Installation, testing & commissioning ofHT 33KV VCB line up of Six panels switchboard consisting of 1250A, VCB 33 KV - 2Nos as incomer with Bus coupler cum Bus Riser 1250A VCB 33 KV-1 No with 1250A VCB 33 KV- 3Nos as outgoing.VCB panel indoortype totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontalisolation, horizontal draw out type VCBs with copper bus bars, Self supported Insulated Busbar with full voltage rated should be used. Complete VCB panel confirming to IEC 62271-200 standards and IP 4X class of protection comprising necessary bus-bars extension and connections and following protective and control devices as specified below. Circuit Breaker shall be suitable for E2, M2 & C2 duty. Vacuum Interrupters of the circuit breakers shall be completely encapsulated in epoxy housing. The manufacturer of circuit breaker & Panel shall also be the manufacturer of the Vacuum Interrupter, Relay. The switchgear and control gear panels shall be of the fully arc proof for 25 kA for 1Sec AFLR complete all as specified and as directed.Make: ABB /CG / Schneider / Siemens. 76 A. INCOMER-2 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories :-a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-200/5+5+5 A Core-1: 15VA Class 0.5, Core -2 5P20, Core -3: Class PS - 3nos.e. Potential Transformer Draw out TypeResin cast Ratio : 33KV/√3/110V/√350VA, CLASS: 0.5-3 Nos.f.12 Window Annunciatorg.Digital Ammeter with ASS.h.Digital Voltmeter with VSS.i.Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.j.Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,k. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS), 87C (differential P) and 64 (Restricted earth fault) .Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 77 B. OUTGOING - 3 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motorb.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-200/5+5A Core-1: 15VA Class 0.5, Core -2 5P20, Core-3 : PS class- 3 nos.e.12 Window Annunciator.f.Digital Ammeter with ASS.g. Digital Voltmeter with VSS.h. Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication i. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,j. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS), 64 (Restricted earth fault).Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 78 C. BUS COUPLER- 1 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,e. Electrical & Mechanical Interlocking.f. Numerical Protection Relay with all protection.g. ABT scheme with Manual Option.Note:The above said panelsEarthing truck -01 nos. Earthing truck shall be so designed that it is impossible to earth alive. It shall be provided with capacitive voltage detection with audio visual annunciation. Technical drgs of the VCB panel submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the VCB panel to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of VCB panel shall be carried out by Senior Electrical Inspector / Electrical Inspector. The VCB panel should be GSM based SCADA compatible. 79 Supply, Installation, Testing and Commissioning of Three Phase 4Wire 110V/50A FCBC Thristor based with in-built DCDB and RS485 communicationsuitable for 110V/200AH VRLA battery with 55 Cellsin complete as specified and directed. Make: Amararaja/Exide 80 Supply, installation, testing and commissioning of cable 3 Core 300 Sq.mm 33KV(E) XLPE cable grade cable of size suitable for earthed system having compacted circular stranded aluminium conductor shielded with semi-conducting compound extruded layer XLPE insulated dry cured core shielded with semi-conducting compound extruded layer followed by metallic copper foil, screened inner sheath of extruded PVC, galvanized single flat steel strip armoured and PVC sheathed overall conforming to IS: 7098/Part-II/1985, as amended upto date with ISI marked of following sizes in VCV manufacturing process.Note- Technical details of the cable submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the cable to be inspected by the rep of accepting officer at Factory premises as per IS before despatch 81 S&F of Cable jointing kit for 33 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 300 Sqmm 3 core complete all as specified and directed. 82 S&F of Cable jointing kit for3 Core 300 Sq.mm 33 KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and directed. 83 S&F of Cable jointing kit for 3 Core 300 Sq.mm 33 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and directed. 84 Supply, laying & testing of 11KV(E)XLPE insulated cable of following sizes suitable for earthed system having compacted circular stranded aluminium conductor shielded with semi-conducting compound extruded layer XLPE insulated dry cured core shielded with semi-conducting compound extruded layer followed by metallic copper foil, screened inner sheath of extruded PVC, galvanized single flat steel strip armoured and PVC sheathed overall conforming to IS: 7098/Part-II/1985, asamended upto date with ISI marked of following sizes in VCV manufacturing process. 85 3 Core 240 Sq.mm 86 3 Core 400 Sq.mm 87 Supply, laying & testing of 11KV(E)XLPE insulated cable of following sizes suitable for earthed system having compacted circular stranded copper conductor 1 core 1000 sqmm shielded with semi-conducting compound extruded layer XLPE insulated dry cured core shielded with semi-conducting compound extruded layer followed by metallic copper foil, screened inner sheath of extruded PVC, galvanized single flat steel strip armoured and PVC sheathed overall conforming to IS: 7098/Part-II/1985, asamended upto date with ISI marked of VCV manufacturing process. 88 S&F for Cable jointing kit for 11 KV grade cable for Outdoor End termination kit heat shrink type joint complete with jointing material and accessories suitable for 1 core 1000 sqmm XLPE armoured copper conductor cable sqmm etc complete all as specified and directed. 89 S&F for Cable jointing kit for 11 KV grade cable for Indoor End termination kit heat shrink type joint complete with jointing material and accessories suitable for 1 core 1000 sqmm XLPE armoured copper conductor cable sqmm etc complete all as specified and directed. 90 S&F for Cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm etc complete all as specified and directed. 91 S&F of Cable jointing kit for 11 KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following sizes etc. complete all as specified and directed. 92 3 Core 240 Sq.mm 93 3 Core 400 Sq.mm 94 Design, Supply, Installation, Testing and Commissioning of GSM based energy management system/ substation automation system with suitable software capable of taking care of complete data monitoring, data logging and control functions at 132 MRS consisting of 2 Nos 132 KV GIS, 6 Nos HT 33 KV VCBs at MRS , 7 Nos 33 KV VCBs at NSB Substation, 8 Nos 11 KV VCBs at NSB and other allied switchgears at 33/11 KV substation at DH complete with servers, work stations, desk top computers, operating system, communication products and object softwares assembled from industry standard products all as specified 95 a) BCU suitable for substation automation.b) Integration with Existing Scada server.c) Fibre/Eithernet switch (for station level & bay level) -8 sets.d) RTU (with redundant RTU , Power Supply & Hot Swappable IO configuration) - 2 set.e) SCADA software.f) Suitable Modems & ALUs.h) Integration with Existing central SCADA software- 1 set.Note- a) The SCADA system is GSM based and to be integrated with existing SCADA server. b) The cost of Connecting cable (e.g-Optical fibre cable Network, CAT 6 cable Armoured/unarmoured etc) and accessories for integration of IED, Ethernet and RTU, ALU, IED (Relay) as required at site is deemed to be included in the unit price. c) Technical drgs of the SCADA submitted by the contractor is required to be approved by the accepting officer before taking procurement action . 96 Supply and fixing in position Retardant/ extinguishing electric insulated synthetic mat2.5 mm (+/-) 10% thick conforming to BIS -DOC No ET-02 (540) dt 30/04/2004, meeting requirements of IS- 3043, IS-5216 (Part-1, 2 & 3), IS-15652:2006 and IEC 479 Pub-I tested having minimum width of 1000 mm (+/-) 20 mm. All allied materials such as PU-Resin Chemical bond (hardener), special PVC adhesive liquid primer and qty required to complete the job as per site requirement suitable for all voltages not exceeding 33/11 KV system complete all as specified. 97 M&L for RCC cable route indicator semi-circular shape on top of size 600x450x100 mm casted in PCC 1:3:6with TMT bar of size 10 mm dia and foundation base casted in RCC 1:2:4, grouted in earth upto 550 mm duly engraved the following letters HT UG CABLEwith two coats of antifungal weather coat paint, etc all as specified and directed. 98 S & F for Display chart (set of 2 nos) of size 6 x 4 duly made on white polyvinyl sheet exactly showing the locations of the yard and the machineries and equipments installed in the sub-station duly marked properly with legends etc, and a separate chart showing the details of machineries installed with nos, capacity/ rating and make with computer cutting letters of approved size on poly vinyl sheet all as specified and directed. 99 S&F for Display chart (set of 2 nos) of size 4 x 5 duly made on white polyvinyl sheet exactly showing the lay out of transmission and distribution of HT UG cable routes, locations of the HT Joints, drawn on autocad, etc duly marked properly with legends, with computer cutting letters of approved size on poly vinyl sheet, all as specified and directed. 100 S & F for shock treatment chartof size 1.5 m x 1.5 m x 0.025 m duly laminated with wooden frame (tick wood)enclosure all as specified and fixed in position as directed by Engineer-in-charge. 101 S & F First aid GI box containing prescribed medicines for first aid box as per standard quality and quantity each as required to provide first aid treatment in an emergency complete all as specified 102 Supply, Installation, Testing and Commissioning of Power transformer step down outdoor type 33/11 KV, capacity 16 MVA (suitable for 10/16MVA cooling), ONAN/ONAF, Vector group Delta/star (Dyn11) with on load tap changing gear (+) 5% to (-)15% in steps of 1.25% on HV side, with HV/LV Cable Box and all standard accessories as per IS 2026 and as specified in PS, including first fill of oil complete comprising the following accessories:-a)Conservator Tankb) Pressure Relief Devicec) Buchholz Relayd) Oil Surge Relaye) Oil Temperature Indicator (OTI)f) Winding Temperature Indicator (WTI)g) Oil Preservation Equipment likeh) Oil Sealingj) Breatherk) Aircell in conservator tankl) Radiators and control valvesm) Each radiator tank shall have its own cooling fans, shut off valves at the top and bottomn) motor operated OLTC shall be o) On load tap changing with RTCC panelp) Marshalling boxq) Thermosphyn filterr) NIFPS to be installed By OEM 103 Note- i) Technical drgs of the Transformer alongwith NIFPS submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the Transformer to be inspected by the rep of accepting officer at various stages at Factory premises as per IS before despatch. Pre-commissioning inspection of Transformer shall be carried out by Senior Electrical Inspector / Electrical Inspector.ii) The rate quoted is deemed to include the cost of PCC / Brick Masonry Foundation / Platform of transformer as per OEM recommendations and finishing the top surface even and smooth.iii) Manufacturer shall possess NABL accredited test lab for electrical testing(Routine test, type test and special test.iv) Type test reports of33/11 KV Transformer of same capacity or higher Such as Temperature rise, Impulse test, Short circuit test , Vacuum Tests of Tank & Radiator, No Load & Load Loss test and tap changer to be submitted by the bidder during Drawing approval 104 Supplying, Installing, Connecting, Commissioning and Testing of Transformer, Step Down, Outdoor Type, Floor or Platform Mounted complete with standard fittings, 33 KV / 433 V [at No load], AC, 3 Phase, 50 Hz, of 100 KVA capacity, Double Copper Wound, K class Natural Ester Oil immersed, CRGO Core type Naturally cooled, Built-up with class A insulation, having Primary Voltage [HT] 33 KV and Secondary Voltage [LT] of 433 Volts, Delta connected on 33 KV Side & Star connected on 433 Volts side, designed & constructed with particular reference to Tropical Condition, conforming to IS – 1180-2014, including PCC / Brick Masonry Foundation / Platform as per IE Rules, fixing HT / LT Busbar and Cables etc. complete all as specified and as directed andcomprising of the following Specification and Fittings:Continuous Rating: 100 KVANo-Load Voltage Ratio : 33 KV / 433 V Tapping on HV[%]: ± 7.5, ± 5, ± 2.5Phase & Frequency : 3 Phase & 50 HzConnection: Delta StarVector Group : DYN 11Cooling : KNANType: OutdoorNote: The rate quoted is deemed to include the cost of PCC / Brick Masonry Foundation / Platform as per OEM recommendations and finishing the top surface even and smooth complete all as per manufacturer’s recommendations, as specified and as directed. 105 Fittings:[a] Externally hand operated Off–Circuit Tap Switch with position indicator and locking device.[b] Conservator with Oil Gauge, filling hole with plug & drain hole with plug[c] Undercarriage with four plain rollers[d] Oil filling hole cum air release plug[e] Drain Valve cum Sampling Valve[f] Top Filter Valve with Plug[g] Rating Plate with Diagram Plate[h] Lifting lugs for Transformer[j] Lifting lugs for Core[k] Earthing Terminals[l] Thermometer Pockets[m] Silica Gel Breather[n] Explosion Vent[o] Marshalling Box with Double Window[p] OCTC.Note- Technical drgs of the Transformer submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the Transformer to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of Transformer shall be carried out by Senior Electrical Inspector / Electrical Inspector. 106 Supply, Installation, testing & commissioning ofHT 33KV VCB line up Seven panels switchboard consisting of 1250A, VCB 33 KV - 2Nos as incomer with Bus coupler cum Bus Riser 1250A VCB 33 KV-1 No with 1250A VCB 33 KV- 4Nos as outgoing.VCB panel indoortype totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontalisolation, horizontal draw out type VCBs with copper bus bars, Self supported Insulated Busbar with full voltage rated should be used. Complete VCB panel confirming to IEC 62271-200 standards and IP 4X class of protection comprising necessary bus-bars extension and connections and following protective and control devices as specified below. Circuit Breaker shall be suitable for E2, M2 & C2 duty. Vacuum Interrupters of the circuit breakers shall be completely encapsulated in epoxy housing. The manufacturer of circuit breaker & Panel shall also be the manufacturer of the Vacuum Interrupter, Relay. The switchgear and control gear panels shall be of the fully arc proof for 25 kA for 1Sec AFLR complete all as specified and as directed.Make: ABB /CG / Schneider / Siemens. 107 A INCOMER-2 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories .a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-200/5+5 Core-1: 15VA Class 0.5, Core -2 5P20 - 3nos.e. Potential Transformer Draw out Type Resin cast Ratio : 33KV/√3/110V/√3100VA, CLASS: 0.5-3 Nos.f.12 Window Annunciator.g.Digital Ammeter with ASS.h.Digital Voltmeter with VSS.i.Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.j.Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,k. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS) and 64 (Restricted earth fault) Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 108 B. OUTGOING - 4 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-200/5+5+5A Core-1: 15VA Class 0.5, Core -2 5P20, Core -3: Class PS - 3nos.e.12 Window Annunciator.f.Digital Ammeter with ASS.g. Digital Voltmeter with VSS.h. Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.i. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,j. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS),Transformer Differential Protecton (except Stn Transformer )64 (Restricted earth fault) Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 109 C. BUSCOUPLER- 1 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,e. Electrical & Mechanical Interlocking.f. Numerical Protection Relay.g. ABT scheme with Manual Option.Note:The above said panelsEarthing truck -01 nos. Separate earthing truckfor bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth alive. It shall be provided with capacitive voltage detection with audio visual annunciation.Technical drgs of the VCB panel submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the VCB panel to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of VCB panel shall be carried out by Senior Electrical Inspector / Electrical Inspector. The VCB panel should be GSM based SCADA compatible. 110 Supply, Installation, testing & commissioning ofHT 11KV, 25 kA, VCB line of Nine panels switchboard consisting of 1250 Amps, VCB 11 KV - 02 Nos as Incomer, Bus coupler 1250Amps VCB 11 KV -1Nos , Outoing 1250AVCB 11 KV- 6 Nos.VCB panel indoortype totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontalisolation, horizontal draw out type VCBs with copper bus bars, Self supported Insulated Busbar with full voltage rated should be used. The switchgear panel shall be of sheet steel constructionnot less than 2.5mm thickness for load bearing section and not less than 2 mm thickness for non-load bearing and shall totally dust and vermin proof. Complete VCB panel confirming to IEC 62271-200 standards and IP 4X class of protection comprising necessary bus-bars extension and connections and following protective and control devices as specified below. Circuit Breaker shall be suitable for E2, M2, C2duty. The manufacturer of circuit breaker & Panel shall also be the manufacturer of the Vacuum Interrupter, Relay. The switchgear and control gear panels shall be of the fully arc proof for 25 kA for 1Sec AFLR complete Make: ABB /CG / Schneider / Siemens. 111 A. INCOMER-2 Nos ( Each consisting of )11kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories:-a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 800-600-400/5+5+5A Core-1: 15VA Class 0.5, Core -2 5P20, Core -3: Class PS - 3nos.e. Potential Transformer Draw out Type Resin cast Ratio : 11KV/√3/110V/√3100VA, CLASS: 0.5-3 Nos.f.12 Window Annunciator.g.Digital Ammeter with ASS.h.Digital Voltmeter with VSS.i.Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.j.Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,l. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS),Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 112 B. OUTGOING - 6 Nos ( Each consisting of )11kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-300-200/5-5A Core-1: 15VA Class 0.5, Core -2 5P20 - 3 nos.e.12 Window Annunciator.f.Digital Ammeter with ASS.g. Digital Voltmeter with VSS.h. Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.i. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,j. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS).Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 113 C. BUSCOUPLER- 1 Nos ( Each consisting of )11kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,e. Electrical & Mechanical Interlocking, ABT scheme with Manual option.Note: The above said panelsEarthing truck -02 nos. Separate earthing truckfor bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth alive. It shall be provided with capacitive voltage detection with audio visual annunciation. Technical drgs of the VCB panel submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the VCB panelto be inspected by rep of the accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of VCB panelshall be carried out by Senior Electrical Inspector / Electrical Inspector. The VCB panel should be GSM based SCADA compatible. 114 Supply, install, test and commission of APFC panel indoor type 1500 KVAR 12.1 KV, complete Make : CG / Shreem /Siemens /BCH.Capacitor panel consisting of below:-83.33 KVAR, 6.98 KV, externally fused capacitor unit for 250K @12.1KV (207K 11KV) step - 12nos.166.67 KVAR, 6.98 KV, externally fused capacitor unit for 500K @12.11 KV (413K 11KV) step - 3nos.11 KV, Air core dry type, class F aluminium wound, 1Ph, 0.2%, series reactor (STC shall be 16.6 times rated current for 2 sec) - 15nos.11KV, 400A, 10KA for 1 Sec, 3 phase vacuum contactor - 15nos.11 KV/110V-190V, 50-50VA, 3Ф resin cast RVT - 1no.11 KV HT HRC fuses of suitable current rating- 15nos.11 KV, 630Amp, 25KA for 1 sec, off load type isolator- 1no.3PH, RC surge suppressor- 1no.APFC relay (RS485/232 communication port)- 1no.Control cable, space heater, timer, thermostat, CFL lamp, LED indication, push button, selector switch, terminal connectors, gasket, limit switch, name plate, hardware - 1 set. 115 S& F spring loaded aluminium clamps suitable for HV & EHV cables of following sizes inculding all necessary items to fix such as nuts, bolts, washers etc. and all fixing arrangements as required at site. 116 Single core 630 Sqmm 132 KV Al cable 117 Three core 300 Sqmm 33 KV Al cable 118 M & L for survey, site inspection, layout design and location identification for complete earthing/earth mat layouting for best result depending on the soil condition at the site of 132KV and 33 KV yard all complete as specified and directed. Survey report alongwith layout drawing in A3 size properly verified by a Engineer to be submitted in triplicate for approval of Engr in charge/GE 119 Material and labour for brick massonary in cement mortar 1:4 of internal size 1000 x 1000 x 800mm for man hole in contol/power cable routes including plastering with cement mortar 1:6 10MM thick internally and externally 150mm below the G.L. with 1:6 cement mortar 15mm thick,PCC 1:4:8type D2 by using 40mm gradded aggregate foundation of size 1550x1550 mm of 150mm thick and PCC 1:3:6 for coping of 50mm thick and covering the chamber with 40X40X4 mm thick angle iron frame and 10mm thick RCC slab with type B0 1:2:4 concrete with 12.5mm graded aggregate as cover with handles made out of MS round bar 10 mm dia for lifting slabs including painting to the angle iron with two coats of synthetic enamel paint over a coat of redoxide primer and white wash for the man hole complete all as directed by Engineer-in-charge. 120 Material and labour for brick massonary in cement mortar 1:4 of internal size 1500 x 1500 x 1400mm for man hole in control cable routes including plastering with cement mortar 1:6 10MM thick internally and externally 150mm below the G.L. with 1:6 cement mortar 15mm thick,PCC 1:4:8type D2 by using 40mm gradded aggregate foundation of size 1550x1550 mm of 150mm thick and PCC 1:3:6 for coping of 50mm thick and covering the chamber with 40X40X4 mm thick angle iron frame and 10mm thick RCC slab with type B0 1:2:4 concrete with 12.5mm graded aggregate as cover with handles made out of MS round bar 10 mm dia for lifting slabs including painting to the angle iron with two coats of synthetic enamel paint over a coat of redoxide primer and white wash for the man hole complete all as directed by Engineer-in-charge. 121 M&L for Providing precastreinforced cement concrete slabs 12.5 cm thick M-30 including reinforcementand 12 mm dia MS handle (with plain or interlocking joints as directed setting in mortar 1:6 of size of slab 1.20x1.20M. 122 LIGHTENING PROTECTION 123 M & L for single pointed Air termination Aluminium Rod 12 mm dia 500 mm long with Aluminium base plate of size 125 x 125 x 10mm fixed over hylam sheet of size 175 x 175 x 10mm and fixed on 1.5 Meter GI pipe 25mm Medium grade on roof all specified and as directed. 124 M & L Earthing complete with GI earth plate electrode 60cmX60cmX6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connecting to galvanized earth strip 32 x 6 mm as earthing conductor by means of bolts, nuts, check nuts and washers of GI and all as shown in Electrical plate No.3 of SSR Part I and including testing on completion all as specified locations and as directed by the Engineer-in-Charge.Note: 1.The above quoted rate shall include cost of main earthing lead of 32 x 6mm GI earth strip, charcoal, salt, excavation and earth work in any type of soil CI cover, funnel with 20mm dia medium grade GIwater pipe including GI protection pipe 40mm dia light grade for earth strip etc., 2. The cost of earth pit is deemed to be included in the unit rate. 125 AC & REF 126 Supply and install split AC units indoor/outdoorof capacity 2 TR, 3 star , Inverter type, single phase complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with copper condenser complete all as specified and directed 127 S& F Voltage Stabiliser 5 KVA, operating voltage range 130-290 Volt, Single phase complete all as specified and directed. 128 SCHEDULE A PART-IXPHASE -II Outsourcing for sub station for the First 11 Monthsduring Defect Liability Period . 129 Outsourcing for manning and operationof HT/LT Electrical sub station at 33/11 KV substation at NSB along with connected equipments installed round the clock (in 03 shifts) of each shift of 08 hours per day including Sunday and holidays complete all as specified and as directed. 130 One skilled operator in each shift 131 One semi skilled operator in each shift 132 SCHEDULE A PART-XPHASE -III Outsourcing for sub station for the Second 11 Monthsduring Defect Liability Period . 133 Outsourcing for manning and operationof HT/LT Electrical sub station at 33/11 KV substation at NSB along with connected equipments installed round the clock (in 03 shifts) of each shift of 08 hours per day including Sunday and holidays complete all as specified and as directed. 134 One skilled operator in each shift 135 One semi skilled operator in each shift 136 SCHEDULE A PART-XIPHASE -IV Outsourcing for sub station for the balance 02 Months after 22 months during Defect Liability Period . 137 Outsourcing for manning and operationof HT/LT Electrical sub station at 33/11 KV substation at NSB along with connected equipments installed round the clock (in 03 shifts) of each shift of 08 hours per day including Sunday and holidays complete all as specified and as directed. 138 One skilled operator in each shift 139 One semi skilled operator in each shift 140 Note for Item No. 127 to 138:-The rate shall include the following[i] For operation of all out door and indoor structures in the same area.[ii] Contractor shall laise with Dolphin hill sub station in case of major breakdown for early restoration of supply.[iii] In case any problem occurs which seems not under thecontrol of the operator, the same shall be immediately intimated to JE/ AGE E/M.[iv] Any additional man power required for early restoration of supply in case of emergency shall be provided by the contractor.[v] The contractor shall abide by the latest labour rules and minimum wages Act. Wages paid by the contractor to the emplopyed persons shall not be less than minimum wages fixed by the state/ central Govt from time to time whichever is higher.[vi] The contractor shall also insure the workmen employed on th job.[vii] The contractor is responsible for insurance, EPF, ESI, labour welfare cess etc., as applicable and shall be paid to the workmen as per existing Rules/ Acts/ regulations etc., and quoted is deemed to include the same. 141 SCHEDULE A PART-XIIPHASE -VOutsourcing for SCADA system for the First Year after Defect Liability Period . 142 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 143 SCHEDULE A PART-XIIIPHASE -VIOutsourcing for SCADA system for the Second Year after Defect Liability Period . 144 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 145 SCHEDULE A PART-XIVPHASE -VIIOutsourcing for SCADA system for the Third Year after Defect Liability Period . 146 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 147 SCHEDULE A PART-XVPHASE -VIIIOutsourcing for SCADA system for the Fourth Year after Defect Liability Period . 148 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 149 SCHEDULE A PART-XVIPHASE -IXOutsourcing for SCADA system for the Fifth year after Defect Liability Period . 150 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 151 SCHEDULE A PART-XVIIPHASE -XOutsourcing for SCADA system for the Sixth year after Defect Liability Period . 152 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 153 SCHEDULE A PART-XVIIIPHASE -XIOutsourcing for SCADA system for the Seventh year after Defect Liability Period . 154 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 155 SCHEDULE A PART-XIXPHASE -XIIOutsourcing for SCADA system for the Eighth year after Defect Liability Period . 156 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 157 Note for Item No. 140 to 155 [i] Cost of all minor spares/ components including OFC cables, Ethernet switches, connectors etc., is deemed to be included in quoted rate and any type of extra charge will not be made by Dept.[ii] All major defective spares shall be replaced by contractor on exchange basis which is deemed to be included in the unit price.[iii] All periodical tests of all safety devices in accordance with relavant safety standards with full oad testing will be borne by the contractor.[iv] Systematically examine & repair all the components such as software, monitors, servers etc., if any defect found,[v] All required special tools to be arranged by the contractor.[vi] Contractor shall be responsible for maintaining adequate lighting, cooling and moisture control, ventilation as required all at site complete.[vii] All safety measures/ directions and required tests for safety devices annually shall be borne by contractor.[viii] All periodical visits and all breakdown calls related to stoppage, malfunction, special services should be attended compulsory during all days including sundays & holidays.[ix] The contractor shall be liable to pay the telecom bill provided by the service provider.
Contract Date: Jan 06, 2026 Contract Value : 23.55 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
Andhra Pradesh View Result →
35.
Educational and Research Institute #9918629 Technical Bid
Supply Of Books To Govt. Medical College, Anantnag. , Department Of Anatomy , Grays Anatomy For Students Richard L. Drake, A. Wayne Vogl, Adam W. M. Mitchell , Clinical Anatomy Richard S. Snell , Human Anatomy Elaine N. Marieb, Katjahoehn , Atlas Of Human Anatomy Frank H. Netter , Essential Clinical Anatomy Keith L. Moore, A. M. Agur, Arthur F. Dalley , Human Anatomy Inderbir Singh , Textbook Of Anatomy Vishram Singh , Anatomy For Medical Students K. L. Rao , Anatomy For Dental Students Rajan K. Gupta , Textbook Of Human Anatomy K. K. Datta , Principles Of Anatomy M. S. M. Rao , Human Anatomy K. L. Ghosh , Textbook Of Anatomy C. A. T. Bhattacharya , Surface Anatomy: The Anatomical Basis Of Clinical Examination S. Das , Clinical Anatomy At A Glance Philip F. Harris, A.J. W. D. Reeve , Human Anatomy: A Photographic Atlas John A. Waldman , Atlas Of Surface Anatomy Morris K. R. Low, David M. Lowe , Radiological Anatomy For The Frcr J. M. Anslow, S. N. Gardiner , Essential Radiological Anatomy Paul Butler, David S. K. Lee , Radiologic Anatomy Of The Abdominal Cavity Fenchel, H., And Heller, M. , An Atlas Of Radiological Anatomy A. A. Chudnovsky, T. I. Jokich , Radiological Anatomy S. K. Sharma , Textbook Of Radiology For Medical Students S. Gupta , Atlas Of Radiological Anatomy Of The Chest K. J. Sandhu , Clinically Oriented Anatomy Keith L. Moore, Arthur F. Dalley, Anne M. Agur , Clinical Anatomy For Medical Students A. J. D. M. Uitvlugt, J. M. Mahler , Essentials Of Clinical Anatomy E. D. S. Loukas, M. M. Awan , Grays Anatomy For Students Richard L. Drake, A. Wayne Vogl, Adam W. M. Mitchell , Elements Of Clinical Anatomy Vishram Singh , Human Anatomy: A Clinical Approach Inderbir Singh , Clinical Anatomy: A Case-Based Approach Prakash K. Sharma , Langmans Medical Embryology T. W. Sadler , The Developing Human: Clinically Oriented Embryology Keith L. Moore, T. V. N. Persaud, Mark G. Torchia , Embryology: An Illustrated Colour Text Andrew T. H. Lee, Steven G. A. Smith , Human Embryology Bruce M. Carlson , Developmental Biology Scott F. Gilbert , Embryology For Medical Students Inderbir Singh , Human Embryology J. M. N. Merhige , Essentials Of Human Embryology N. Kumar , Textbook Of Human Embryology Vishram Singh , Histology: A Text And Atlas Michael H. Ross, Wojciechpawlina , Basic Histology: Text And Atlas Luiz Carlos Junqueira, José Carneiro , Color Atlas Of Histology Michael J. Leboff , Histology For Pathologists Stacey E. Mills , Essentials Of Histology William C. W. K. Smith, Michael G. Sommers , Textbook Of Histology G. K. S. Rao , Human Histology K. S. D. K. P. Sharma , Histology And Cell Biology Bhaskar K. S. Rao, Sunil Kumar , Osteology: A Clinical Approach Matthew A. Johnson , Fundamentals Of Osteology J. W. L. Harris , Atlas Of Human Osteology F. H. Netter , Human Osteology Tim D. White, Michael T. Black, Pieter A. Folkens , Clinical Osteology: An Introduction To The Anatomy Of The Skeleton David J. H. Harne , Textbook Of Osteology Inderbir Singh , Osteology And Arthrology S. M. L. Bhadani , Fundamentals Of Anatomy And Physiology Frederic H. Martini, Judi L. Nath, Edwin F. Bartholomew , Anatomy And Physiology For Nurses Roger Watson, Marilyn Evans , Essentials Of Human Anatomy And Physiology Elaine N. Marieb , Anatomy & Physiology For Nursing And Healthcare J. A. H. Waugh, A. M. Grant , Human Anatomy & Physiology Erin C. Amerman , Manual Of Human Anatomy J. B. D. Dutta , Textbook Of Anatomy For Paramedical Students Vishram Singh , Clinical Anatomy For Paramedical Studies J. C. V. A. Tiwari , Anatomy For The Emergency Medical Services C. J. R. Cross , Essentials Of Anatomy & Physiology For Paramedic Practice C. J. H. Mckimm , Gray’S Anatomy The Anatomical Basis Of Clinical Practice Susan Standring , Gray’S Atlas Of Anatomy Richard L.Drake , Gray’S Anatomy Review Marioslokas , Thieme Atlas Of Anatomy Anne M. Gilroy , Sobotta Atlas Of Human Anatomy Urban And Fischar , Mcminn”Scolour Atlas Of Head And Neck Anatomy Bari M. Logan , Clinical Atlas Of Human Anatomy Abrahams And Mcminns , Larscen”S Human Embryology Schoenwolf , The Developing Human Keith L.Moore , Human Anatomy The Definitive Visual Guide Proff Alice Roberts , Clinical Anatomy Flash Cards Douglas J.Gould , Clinical Anatomy (Applied Anatomy For Students And Junior Doctors) Harold Ellis , Illustrated Clinical Anatomy Peter Abhram , Clinical Anatomy (Problem Solving Approach) Neta V Kolkurani , Lippincott’S Concise Illustrated Anatomy Benkasy , Netters Clinical Anatomy Jonn T Hansen , Trial Guide To The Body Andrew Biel , Bancroft’S Theory And Practice Of Histological Techniques S. Kim Suvarana , Wheater’S Functional Histology Barbara Young , Histology A Text And Atlas With Correlated Cell And Biology Wojciechpawlina , Color Atlas And Text Of Histology Leslie P Gartner , Netters Anatomy Flash Cards John T Hanson , Netters Surgical Anatomy And Approaches Conor P Delaley , Netters Concise Radiological Anatomy Edward C Webber , Snells Clinical Neuro Anatomy Splittgibar , Fitzgerlads Clinical Neuroanatomy And Neuroscience Estomihmtui , Neuroanatomy Through Clinical Cases Hal-Blumenfeld , The Clinical Anatomy Of Cranial Nerves Joela.Vilensky , Cranial Nerves Functional Anatomy Stanleymonksey , The Human Brain Book Rita Carter , Department Of Anaesthesiology , Miller’S Anesthesia-, Gropper, Erikson, Fisher Latest Edition , Stoelting’S Anesthesia And Co- Exiting Diseases Hines, Marschall , Morgan & Mikhail’S Clinical Anesthesiology Butterworth, Mackey, Wasnick , Chestnut’S Obestric Anesthesia Chestnut Wong , A Practice Of Anesthesia For Infants And Children Cote, Lerman, Anderson , Textbook Of Pediatric Anesthesia Bosenburg, Lerman, Anderson , Kaplan’S Cardiac Anesthesia Kaplan, Augoustides , Barash Clinical Anesthesia Barash, Cahalan, Cullen , Lee’S Synopsis Of Anesthesia Nimmo, Fisher, Macg Palmer , Nysor’S Regional Anesthesia Textbook Hadzic , Benumof’S Airway Management Benumof, Hagberg , Oxford Textbook Of Anesthesia Allman, Wilson , Practical Approach To Anesthesia Equipment Ehrenwerth, Eisenkraft , Principles And Practice Of Mechanical Ventilation Tobin , Complications In Anesthesia Goba,Fish, Howard , Understanding Anesthesia Equipment Dwivedi , Essentials Of Neuroanesthesia Matta, Menon , Textbook Of Pain Mcmohan,Koltzenburg , Anesthesiologist’S Manual Og Surgical Procedures Jaffe, Samuels , Department Of Biochemistry , Tietz Textbook Of Clinical Chemistry And Molecular Diagnostics Nader Rafai, Andera Rita Horvath , Tietz Fundamental Of Clinical Chemistry And Molecular Diagnostics Nader Rifai, Rossa Wk Chiu , Clinical Chemistry Principles, Techniques And Correlations Michael L Bishop , Clinical Biochemistry Metabolic And Clinical Aspects Marshall Marta Lapsley , Ambika Shanmugam’S Fundamentals Of Biochemistry For Medical Students Ambika Shanmugam , Biochemistry By Pankaja Naik Pankaja Naik , Textbook Of Clinical Biochemistry Poonam Agarwal , Early Clinical Exposure In Biochemistry Neeru Bhaskar , Henry’S Clinical Diagnosis And Management By Laboratory Methods Richard A.Mcpherson , Practical Clinical Biochemistry Methods And Interpretation Ranjana Chawala , Manual Of Practical Biochemistry Rafi Md , Illustrated Practical Biochemistry Dr Shabhiya Majid , Practical Biochemistry With Clinical Correlation Poonam Agarwal , Clinical Cases In Biochemistry Ashish Sharma Anita Sharma , Department Of Community Medicine , Maxcy Rosenau Last Public Health & Preventive Medicine Wallace Rb , Barker Djp, Practical Epidemiology Churchill Living Stone , Biostatics: A Foundation For Analysis In Health Sciences Dannie Ww , Manson’S Tropical Diseases Cook G Zumia A , Epidemiology In Medical Practice Barker Djp , Textbook Of Infectious Diseases Cristee , Basic And Clinical Epidemiology Vikas Dhikav , Basic Epidemiology R Beaglehole , Essentials Of Epidemiology B Shridhar Rao , Epidemiology Biostatics Preventive Medicine And Public Health Kartz Elmore , Clinical Dietetics And Nutrition Anita And Abrah , Medicine In Society Behaviour Science In Medical Students Cristopher Dow , Textbook Of Community Medicine Preventive And Social Medicine Sundar Lal Adar , Challenging Facts Of Childhood Wellness Slater , Encyclopedia Of Family Health And Wellness Berlan , Epidemiology Advanced Study And Practices Andrew , Parks Textbook Of Preventive And Social Medicine K Park , Modern Medical Statistics Everit , National Health Programs Of India J Kishore , Public Health And Infectious Disease Hammer Grifiths , Textbook Of Community Medicine Rajvir Balwar , Preventive And Social Medicine K Park , Textbook Of Community Medicine Sundar Lal Adhar , Gordis Epidemiology Celentano Szklo , Modern Epidemiology Rothman Greenland , Epidemiology Rothman , Epidemiology And Management For Health Care Pv Sathe , Mahajans Methods In Biostatics Banerjee , Mnaual Of Nutrition Therapeutics David H Albers , Hunters Disease Of Occupations Baxter Cockcro , Clinical Epidemiology The Essentials Fletcher , Studying A Study And Testing A Test Riegelman , Dc Duttas Textbook Of Obstetrics Konar , Nelson Essentials Of Pediatrics Surjit Singh Pra , Harrisons Principles Of Internal Medicine Jameson Fauci , Community Medicine Practical Manual Patil , Encyclopedia Of Public Health Kirch Ed , Health And Social Justice Ruger , Devlopment Of Modern Epidemiology Holland Olson , Community Medicine With Recent Advances Surya Kantha , Oxford Textbook Of Global Public Health Roger Detels , Mahajan And Gupta Textbook Of S Preventive And Social Medicine Roy Saha , Principles And Practice Of Community Medicine Rahim , Modern Infectious Diseases Epidemiology Giesecke , Hospital Epidemiology And Control Mayhall , Medical Statics A Textbook Of Health Sciences Machin Campbell , Simple Biostatics A Indrayan , Hospital Administration Francis D Souza , Modern Nutrition In Health And Diseases Ross Cabalero , A Review Of Preventive And Social Medicine Lahariya , Ghai Essential Pediatrics Paul Bhagga , Holland And Brew Manual Of Obstetrics Daftray Chakra , Essentials Of Community Medicine Pradticals Maha Bala Raju , Dietetics B Sri Lakshmi , Mcwhinneys Textbook Of Family Medicine Freeman , Basic Methods Of Medical Research Abhaya Indrayan , The Hospital Administrator George , Modern Nutrition In Health And Disease Ross Cabalero , Dk Tinajas Health Policies Programs Banerjee , Community Medicine Practical Guide Gaur Soni Yadav , Practical And Viva Community Medicine J Kishore , Management Of Childhood Obesity Elizabeth Paskit , Munros Statistical Methids For Health Care Research Kallar Kelvin , The New Public Health Tulchin Sky , Introduction To Biostatics And Research Methods Roa Richard , Statistics For Management Lavin Rabin Siddique , Essentials Of Management Massie , Medical Records Organazation And Management Mogli , Lessons From Grand Rounds Ambedkar , Epidemiology Concepts And Methods Willim Oleckno , A Dictionary Of Epidemiology Porta , Modern Infectious Diseases Epidemiology Pv Sathe , Introduction To Biostatistics And Research Methods Rao Richard , Hospital And Nursing Homes Planning Oraanization And Management Tabish , Manual Of Nutritional Therapeutics David H Albers , A Dictionary Of Public Health J Kishore , A Review And Preventive Of Social Medicine Lahariya , Nelson Essentials Of Pediatrics Paul Bagga , Health Care Systems And Management Sl Geol , Methods For Economic Evaluation Of Health Care Programmes Dromond Stod , Tropical Infectious Disease Guerant , Red Book Of 2018-2021 Report Of The Committee On Infectious Diseases David W Kimber , Department Of Dentistry , White Pharoh (Oral Radiology) 8Th Edition , Oral And Maxillofacial Surgery Bhalaji 4Th Edition , Oral And Maxillofacial Infection- Topazian 4Th Edition , Department Of Dermatology , Lever’S Histopathology Of Skin Lever , Dermatology & Sexually Transmitted Diseases Neena Khan , Sexually Transmitted Disease & Hiv/Aids By Vinod Sharma , Textbook Of Dermatosurgery & Cosmetology Satish S Savant , Illustrated Textbook Of Dermatology Pasricha , Colour Atlas Of Dermatology Martin Roedeu , Colour Atlas And Synopsis Of Clinical Dermatology Fitzpatrick , Clinical Dermatology Habif , Colour Atlas Of Dermatology R Bhutani , Fitzpatrick Text Book Of Dermatology Sewon Kang , Acsi Textbook Of Dermatology , Harpaer Textbook Of Paediatric Dermatology Harpaer , King Holmes Textbook Of Sexually Transmitted Disease King Holme , Sam Lam 360 Hair Transplant , Jopling’S Text Book Of Leprosy , Ial Text Book Of Leprosy , Andrews Disease Of Skin Clinical Dermatology International Edition 12E James , Dermatology Vol-1,2 Samule L Moschella Harry , Andrews Disease Of Skin Clinical Atlas James , Roxburgh’S Common Skin Disease Motely, Marks , A Colour Hand Book Of Dermatology By Rycroft Rycroft , Aesthetic Dermatology Current Perspectives Sharad Jai Shree , An Atlas Illustration Hiv In Dermatology Shah , Atlas Of Cosmetic Surgery With Dvd Kaminer Md Michaels , Biopsy Interpretation Of Skin Crowson , Colour Atlas Of Nails Tosti , Comprehensive Overview Of Psoriasis Emily Howling , Cosmetalogy And Dermatology Deb Willis , Dermatopathology Brehmer- Andersson , Differential Diagnosis In Dermatology Richard Ashton , Laser And Light Treatment In Asian Skin (Lltas) Cclms Committee , Nails Diagnosis Therapy, Surgery Scher , Skin Aging Gilchrest , Skin Biopsy: Diagnosis And Treatment Heidi Mueller , Skin Hair And Nails; Structure And Function Alan Churchill , Textbook Of Dermatology, Venereology & Leprology Thappa , Treatment And Management Of Melanoma Frederick Nash , Vitiligo Management And Effective Remedies Frederick Nash , Wound Healing And Ulcers Of Skin Shai , Dermatology Hiv & Std In General Practice Mahajan , Hypopigmentation Nicolaidou , Skin Grafts And Flaps Heidi Mueller , Psoriasis Treatment, Cause And Symptoms Andrew Abraham , Infectious Diseases Of The Skin Elston , Practical Aspects Of Hair Transplantation Justin Greene , Hair Transplantation Unger , Fitzpatrick’S Color Atlas And Synopsis Of Clinical Dermatology Wolff , Hair Transplantation Avram , Hastings Textbook Of Leprosy Robert C Hasting , Department Of Ent , Scott- Brown’S Otorhinolaryngology And Head And Neck Surgery 8Th Edition , Cummings Otolaryngology : Head And Neck Surgery 7Th Edition , Stell & Maran’S Head And Neck Surgery And Oncology 6Th Edition , Glasscock Shambaugh Surgery Of The Ear 6Th Edition , Manual Of Middle Ear Surgery By Mirko Toss 3 Volume (1995/1997/2013) , Clinical Audio Vestibulometry For Otologists And Neurologists Biswas 5Th Edition , Endoscopic Sinus Surgery- Anatomy Three – Dimensional Reconstruction, And Surgical Technique Wormald 4Th Edition , Surgery Of The Larynx And Hypopharynx Sultan Pardhan , Sataloff’S Comprehensive Textbook Of Otolaryngology: Head And Neck Surgery 1St Edition , Anatomical Principles Of Endoscopic Sinus Surgery,Brado, Renuka , Atlas Of Endoscopic Sinus And Skull Base Surgery : Palmer, James N , Chiu, Alexander G , Atlas Of Head And Neck Surgery: Cohen, James I , Clayman Gray , Atlas Of Microsurgery Of The Lateral Skull Base: Sanna Mario , Atlas Of Middle Ear Surgery : Gersdorff, Michel, Gerard Jean- Marc , Atlas Of Operative Otolaryngology And Head And Neck Surgery: Rhinology & Anterior Skullbase Surgery( Including Endoscopic Sinus Surgery) Hathiram, Bachi T, Khattar , Atlas Of Skull Base Surgery And Neurotology: Jackler, Robert K , Bailey’S Head And Neck Surgery: Otolaryngology; Johnson, Jonast , Cochlear Implant Principles And Practice: Niparko John K (2009) , Colour Atlas Of Endo- Otoscopy; Examnation- Diagnosis- Treatment; Sanna, Mario (2017) , Complications In Otolaryngology- Head And Neck Surgery; Bernal- Sprekelsen , Diseases Of Ear, Nose, Throat ( Otorhinolarynology (Ent)Base On New Competency- Based Medical Education (Cbme) Ent Curiculum For Indianmedical Graduate (Img)Gmer 2019 Of National Medical Commission (Nmc) Mci; Bansal , Essentials Of Septorhinoplasy: Philosophy, Approaches, Techniques, Behrbohm,Hans; Trady, M Eugene (2017) , Head And Neck Surgery (Surgical Techniques In Otolaryngology Head & Neck Surgery ) ; Goldenberg, David (2016) , Head & Neck Trauma; An Interdisciplinary Approach; Ernst, Arne, Herzog Michael;Seidl, Rainer Ottis (2016) , Jatin Shah’S Head & Neck Surgery And Oncology; Shah, Jatin P, Patel, Senehalg(2020) 5Th Edition , Juvenile Nasopharyngeal Angiofibroma; Janakiram, Narayanan Ed (2017) , Language Disorders From Infancy Through Adolescence; Listening, Speaking, Reading,Writeing And Communicating ; Paul, Reha,Norbury, Courteanay (2012) , Laryngeal Surgery (Surgical Technique In Otolaryngology Head & Neck Surgery) + Interactivedvd-Rom; Sataloff , Robert T (2014) , Laser In Otorhinolaryngology; Current Topics In Otolaryngology- Head & Neck Surgery: Huettenbrink, Karlbernd Ed (2005) , Manual Of Clinical Cases In Ent And Head And Neck Surgery; A Stepwise Approach According To The Latest Cbme Guidelines, Competency Based Undergraduate Curriculumfor The Indian Medical Graduate; Swain, Santosh Kumar (2022) , Microsurgery Of Skull Base Paragangliomas; Sanna, Mario Ed (2013) , Middle Ear And Mastoid Microsurgery; Sunna, Mario (2012) , Paparella’S Otolarynology Head & Neck Surgery; Paparella , Michaelm, Dacosta Sasy Salaimen; Fagan Johannes Jacobus Ed (2020) , Pediatric Otorhinolaryngology; Diagnosis And Treatment (Otorhinilaryngology- Head And Neck Surgery Sries ) .,Licameli, Gerg R; Tunkel, David E (2013) , Cummings Pediatric Otolaryngology 2Ed (Hb 2022) , Phonosurgery; Theory And Practice; Isshiki, Nobuhiko , Rhinologic And Sleep Apnea Surigical Techniques; Kountakis, Stilianos E, Onerci Metin Ed (2007) , Surgery Of The Thyroid And Parathyroid Glands ; Gregory W Ed (2021) , The Temporal Bone ; A Manual For Dissection And Surgical Approaches, Sanna Mario (2006) , Head And Neck Imaging -2 Volume Set 5Th Edition M Somcurtin , Department Of Forensic Medicine , The Essentials Of Forensic Medicine & Toxicology National Jay Pee 36Th Edition , A Text Book Of Medical Jurisprudence & Toxicology (Modi) National Lexis Nexis 28Th Edition , Knights Forensic Pathology International Crc Press 5Th Edition , Parikh’S Colour Atlas Of Medico Legal Post-Mortems & Forensic Pathology National Cbc Publishers & Distributors 4Thedition , Estimation Of The Times Science Death International Crc Press 4Th Edition , Concise Forensic Medicine & Toxicology With Practical Fmt National Cbc Publishers & Distributors , Embalming Principles And Legal Aspects National Jay Pee 2Nd Edition , The Synopsis Of Forensic Medicine & Toxicology National Jay Pee 31St Edition , The Hospital Autopsy International Crc Press 3Rd Edition , Techniques Of Crime Scene Investigation International Crc Press 9Th Edition , Encyclopaedia Of Forensic And Legal Medicine International Elsevier 3Rd Edition , Text Book Of Forensic & Toxicology- By Anil Agarwal National Arya Publishing Company 2Nd Edition , Text Book Of Forensic Medicine & Toxicology; Principles And Practice International Elsevier , Text Book Of Forensic Medicine & Toxicology National Paras Medical Publishers 20Th Edition , Review Of Forensic Medicine & Toxicology By Gautam Biswas National Jay Pee 6Th Edition , Department Of Medical Education Unit (Meu) , Text Book Of Bioethics, Medical Ethics And Health Laws Russel D Souza , Principles Of Medical Education Tajinder Singh , Hand Book On Medical Education Vinod Kumar , Educational Technologies In Medical And Health Science Education Susan Bridgaes , Recent Advance In Medical Education, Knowledge And Research Prof. Dr. Atul Choube , Achieving Excellence In Medical Education Richard B Gunderman , Medical Education- Developing A Curriculum For Practice Della Fish & Coli Coles , Medical Education- A Dictionary Of Quotations Kieran Walsh , Implementation Problem Based Medical Education Arthur Kaufman , Curriculum Development For Medical Education Patrica A Thomas, David E Kerri , Department Of General Medicine , Harrison 21St Edition International Mc Graw Hill Education , Fishmans Pulmonary Disease Latest Edition International Mc Graw Hill Education 6Th Edition , Comprehensive Clinical Nephrology By Fehali International Elsevier 7Th Edition , Williams Endocrinology International Elsevier 15Th Edition , Ibraunwalds Cardiology International Elsevier 12Th Edition , Mandell, Douglas And Bennett’S Principles And Practice Of Infectious Diseases International Elsevier 9Th Edition , Bradley And Daroff’S Neurology In Clinical Practice Vol -2 By Jankovic Josheph International Elsevier 8Th Edition , Goldman Cecil Medicine International Elsevier , Slesinger Fordtran’S Gastrointestinal And Liver Disease International Elsevier , Williams Haematology International Mc Graw Education 10Th Edition , Firestein And Kelley’S Text Book Of Rheumatology International Mc Graw Education 12Th Edition , Principles And Practice Of Sleep Medicine By Meir H Kryger International Elsevier , Department Of Microbiology , Antibiotics Basics For Clinicians Alan R. Hauser , Essentials Of Hospital Infection Control Apurba S. Shastri , Mandell, Douglas, And Bennett’S Principles And Practice Of Infectious Diseases Bennett , Hospital Epidemiology And Infection Control C. Glen Mayhall , Clinical Immunology And Serology, A Laboratory Perspective Christine , Research Methodology- Methods And Mechanics Cr Kothari Gawran Garg , Oxford Textbook Of Medical Mycology Cristopher C Kibbler , Antibodies For Infectious Diseases Crowe , Stites Medical Microbiology Daniel P. Stites , Antisepsis, Disinfection And Sterilization Gerald E. Mcdonnell , Gillespie’S Medical Microbiology Gillespie , Text Book Of Pharmacology & Pharmacotherapeutics Goodman Gilman , Color Atlas Of Mycology Gordon L Lov , Clinical Microbiology Procedures Hand Book Henery And Isenberg , A Guide To Specimen Management In Clinical Laboratory J. Michael, Shelley A. Miller , Infectious Disease And Public Health Griffiths , Clinical Microbiology Procedures Hand Book Henery And Isenberg , A Guide To Specimen Management In Clinical Laboratory J. Michael, Shelley A. Miller , Medical Microbiology Jawetz , Virology Principles And Applications John Carter , Parks Textbook Of Preventive And Social Medicine K Park , Antibiotic Resistance Understanding And Responding To An Emerging Crisis Karl Drlica , Manual Of Diagnostic Antibodies For Immuno-Histology Leong , Practical Medical Microbiology 13Th Edition. Mackie And Mc Cartney , A Guide To Specimen Management In Clinical Microbiology. Miller , Laboratory Manual Minatus , Mycology Moore , Text Book Of Medical Laboratory Technology Praful B. Godkar , Prescott’S Microbiology Presco , Bacterial Resistance To Antimicrobials Richard G Wax , Clinical Laboratory Science Review Robert R Harr , Text Book Of Pathology Robins , Infections Of Leisure Schlossberg , Practical Microbiology Stokes , Microbiology And Clinical Approach Strelkasker , Advanced Microscopy In Mycology Tanya Dahms , Larone’S Medically Important Fungi (A Guide To Identification) Thomas J. Walsh Randall T. Hayden , Textbook Of Medical Laboratory Technology V H Talib , Atlas Of Tropical Medicine And Parasitology Wallace Peters Geoffery Parsol , Antibiotics Walsh , Bennetts And Brachman’S Hospital Infection William R Jarvis , Essentials Of Practical Microbiology {2Nd Edition} Apurba S. Shastry Sandhya Bhat , Text Book Of Microbiology Arora , Text Book Of Microbiology Baveja , Benson’S Microbiological Applications Benson , Bacterial-Epihelial Cell Cross-Talk (Advances In Molecular And Cellular Microbiology) Beth A. Mccormick , Current Laboratory Techniques In Rabies Diagnosis, Research And Prevention Charles Rupprecht , Immunology, International Edition, 9Thedn. David Male & Stokes Peebles , Nester’S Microbiology: A Human Perspective, 8Th Edition Denise Anderson, Sarah Salm, Deborah Allen And Eugene Nester , Practical Microbiology Dr. R.S. Gaud And Dr. G. D. Gupta , Practical Handbook Of Microbiology Emanuel Goldman ,Lorrence H Green , Oxford Handbook Of Infectious Diseases And Microbiology Estée Töéröek & Fiona Cooke , Molecular Cloning: A Laboratory Manual, 3Rd Edition Joe Sambrook , Essentials Of Molecular Biology George M Malacinski , Color Atlas Of Mycology Gordon L Love, Jullie A Ribes , Disinfection And Decontamination: Principles, Applications And Related Issues Gurusamy Manivannan , Infection Control In The Intensive Care Unit, 2Nd Edition (Topics In Anaesthesia And Critical Care) H.K.F. Van Saene & L. Silvestri & M.A. De La Cal , Microbiology A Laboratory Experience Holly Ahern , Master Medicine: Microbiology And Infection: A Clinical Oriented Core Text With Self-Assessment, 3Rd Edn. Inglis , Microbiology: Principles And Explorations, 9Th Edition Jacquelyn G. Black And Laura J. Black , Competency Based Practical Manual For Microbiology Jagdish Chander , Introduction To Cell And Tissue Culture Theory And Technique Jennie P. Mather And Penelope E. Roberts , Introduction To Clinical Infectious Diseases: A Problem-Based Approach Joseph Domachowske , Cell Culture Technology Kasper, Cornella, Charwet , A Guide To The Study Of Basic Medical Mycology Kee Peng Ng , Shiang Ling Na , Tuck Soon Soo-Hoo , Clinical Microbiology 2Nd Edition Keith Struthers , Brs Microbiology And Immunology, 6Th Edition Louise Hawley, Benjamin Cl6arke And Richard J. Ziegler , Fungal Infection: Diagnosis And Management Malcolm Richardson & David W. Warnock , Clinical Microbiology Made Ridiculously Simple, 6Th Edition Mark Gladwin, Bill Trattler And C. Scott Mahan , Microbiology: Laboratory Theory And Application, 3Rd Edition Michael J. Leboffe And Burton E. Pierce , Brock Biology Of Microorganisms, 14Th Edition Michael T. Madigan , Bacterial Adhesion To Host Tissues: Mechanisms And Consequences Michael Wilson , Cell Culture Techniques Micheal Aschner, Cristina Sunol , A Mycology Atlas Prof. Khaled H. Abu Elteen , Atlas Of Medical Mycology Reena Ray Gosh , Henrys Clinical Diagnosis And Management By Laboratory Methods, 22Nd Edition Richard A. Mcpherson Md & Matthe , Molecular Cloning { 3 Volumes} Sambrook And Russell , Practical’S In Microbiology Sengupta , Medical Microbiology And Immunology, Examination And Board Review Warren Levinson Ernest Jawetz , Molecular Biology Of The Gene Watson –Baker-Bell- Gann , Essentials Of Clinical Infectious Diseases William F. Wright , Department Of Obstetrics And Gynaecology , Abortion Spontaneous Abortion, Induced Abortion , Clinics In Obstetrics And Gynaecology , Maternal Diet And Fotel Growth: A Bio- Cultural Exploration , Pcos: More Than Just A Hormone Disorder , Hand Book Of Gynaecpathology- A Simplified Approach In Nutshell , Atlas Of Pelvie Anatomy And Gynecologic Surgery By Michael S, Baggish, Mickey M , Atlas Of Gynaecologic Surgical Pathology By Philip B Clement, Jennifer Staall,Robert H , Breastfeeding : A Guide For The Medical Profession By Ruth A Lawtence, Rebort M , Callen’S Ultrasonography In Obstetrics And Gynecology By Peter W , Callen, Marry E Nortonclinical Obstetrics And Gyanecology By Brain A Magowan, Andrew Thomson, Philips , Comprehensive Care Of The Transgender Patient By Cecile A, Ferrando , Comprehensive Gynecology By Rogerio A, Lobo; David M Gershenson, Gretchen M , Creasy And Resnik’S Maternal- Fetal Medicine; Principles And Practice By Robert Resnik , Current Diagnosis And Treatmeant Obsterics And Gynecology By Lauren Nathan, Ashley S Roman , Diagnostic Gynecologic And Obstetrics Pathology By Christopher P, Crum,Hope K , Drugs During Pregnancy And Lactation By Christof Schaefer, Paul W J Peters , Drugs For Pregnant And Lactating Women By Carl P, Weinger, Clifford Mason , Emans Laufer, Goldstein’S Pediatric And Adolescent Gynaecology By S Jean Emans , Endocrine And Reproductive Physiology By Bruce White, John R Harrison, Lisa Mehlmann , Gynecologic And Obstetric Pathology By Christopher P Crum, Michelle S Hirsch , Gynecologic Ultrasound; A Problem- Based Approach By Beryl R Benacerraf, Steven R , Hacker And Moore’S Essentials Of Obstetrics And Gynecology By Neville F Hacker Joseph C , Munro Kerr’S Operative Obstetrics By Sabaratman Arulkumsran, Michael Robson , Netter’S Obstetrics And Gynecology By Roger P Smith , Noninvasive Prenatal Testing (Nipt) By Lieve Page- Christiaens , Obstetric Immaging ; Fetal Diagnosis And Care By Joshua Copel; Mary E D Alton , Obstetrics; Normal And Problem Pregnancies By Mark B London: Henry L, Galan , Pathology Of The Female Reproductive Tract By Geroge L Mutter, Jaime Prat , Principles Of Gynecologic Oncology Surgery By Pedro T Ramirez, Michael Frumovitz , Smith’S Recognizable Patterns Of Human Deformation By John M Graham, Pedro A. , Surgical Management Of The Transgender Patient By Loren S Schechter , Twining’S Text Book Of Fetal Abnormalities By Anne Marie Coady, Sarah Bower. , Urogynecology And Reconstructive Pelvic By Mark D Walaters, Mickey M Karram , Williams Gynecology By Joshep I , Schaffer, Karen D , Williams Obstetrics 25Th Edition By Kenneth J Leveno, Jodi S Dashe. , Yen And Jaffe’S Reproductive Endocrinology By Jerome F Strauss, Robert Barbieri , Department Of Ophthalmology , Principles And Practice Of Ophthalmology 5Th Edition , Ophthalmology (Yanoff Duker) 4Th Edition , Clinical Ophthalmology 2Nd Edition , Wolffs Anatomy Of Eye And Orbit 8Th Edition , Textbook Of Ophthalmology 6Th Edition , Parson’S Diseases Of The Eye 18Th Edition , Surgical And Medical Management Of Pterygium , Review Of Ophthalmologyisgs Textbook Of Glaucoma Surgery 1St Edition , Current Concept In Refractive Surgery , Refractive Surgery With Phakic Iols , Cornea (Surgery Of Cornea And Conjunctiva) 4Th Edition , Cornea Atlas 3Rd Edition , Cornea (Fundamentals Diagnosis And Management) 4Th Edition , Clinical Neuro Ophthalmology , Retinoblastoma , Handbook Of Neuroimaging For The Ophthalmologists , Clinical Neuro Ophthalmology (Walsh And Hyte’S) 3Rd Edition , Neuro Ophthalmology (Khurana) 1St Edition , Oculoplastic Surgery , Oculoplastic Surgery Atlas , Disorders Of Lens And Cataract Surgey , Master Guide To Manual Small Incision Cataract Surgery , Text Book Of Ophthalmology , A Manual Of Systematic Eyelid Surgery , The Yake Guide To Ophthalmic Surgery , Phaco,Phcokit And Laser Phaco , Clinical Practice In Sics , Master Techniques In Ophthalmic Surgery 2Nd Edition , Laser Applications In Ophthalmology , Innovative Techniques In Ophthalmology , Medical Legal Provisions In Ophthalmology , Investigative Techniques And Ocular Examination , Practical Manual Of Intraocular Inflammation , Review Of Ophthalmology 5Th Edition , Tumours (All In One) , Essentials Of Ophthalmology , Recent Advances In Ophthalmology , Step By Step Glaucoma Surgery , Sarp Ophthalmology , Questions In Ophthalmology , Basic Principles In Management Of Retinal Detachment , Manual Of Ocular Diagnosis And Therapy 3Rd Edition , Essentials Of Ophthalmology 4Th Edition , Advances And Practice Of Ophthalmology 3Rd Edition , Theory And Practice Of Squint And Orthotics , Clinical Ophthalmology 2Nd Edition , Step By Step Lasik Surgery , Manual Of Sics , Glaucoma , Neuro Ophthalmology (Rapid Diagnosis In Ophthalmology) , Goniscopy A Text And Atlas , Department Of Pathology , Fineneedleaspirationcytology 5Th Edition 2012 , Surgicalpathology 11Th Edition 2018 , Diagnostic Surgical Pathology 7Th Edition 2022 , Cytology Diagnostic Principles And Clinical Correlates 6Th Edition 2026 , Diagnostic Cytopathology 3Rd Edition 2010 , The Bethesda System Of Riportingcervicel System 3Rd Edition 2015 , The Bethesda System For Reporting Thyroid Cytopathology 3Nd Edition 2023 , Histo Pathology Of The Skin 12Th Edition 2023 , Histopathology;17/18/19/20/21/22/23/24/25/26/27 Each , Hematology;1/2/3/4 Each , Pathology Of The Lever 8Th Edition 2024 , Basic And Advanced Laboratory 2Nd Edition 2023 , Manual Of Surgical Pathology 4Rd Edition 2022 , Skinpathology 6Th Edition 2025 , Pathology Of The Kidney 8Th Edition 2023 , Functional Histology 7Th Edition 2023 , Ofsurgicalpathology 3Rd Edition 2019 , Tatamemorialhospital 2Nd Edition 2022 , Biopsyinterpretationtatamemorialhospital New , Diagnostic Pathology 3Rd Edition 2024 , The Paris System For Reporting Urinary Cytology 2Nd Edition 2022 , The Milan System For Reporting Salivary Gland Cytopathology 2Nd Edition 2023 , Quick Reference Handbook For Surgical Pathologists 2Nd Edition 2019 , Histology For Pathologists 5Th Edition 2020 , Basic Pathology 11Th Edition 2023 , Robbins,Cotran & Kumar Pathologic Basis Of Disease 11Th Edition 2026 , Diagnostic Immunohistochemistry 6Th Edition 2021 , Theory Exam Answer Manual Pathology [For Md & Dnb Students] 4Rd Edition 2024 , Clinical Pathologist 2000 Mcqs 8Practice Tests 2023 , Differential Diagnosis In Cytopathology 3Rd Edition 2021 , The International Academy Of Cytology Yokohama System For Reporting Breast Fine Needle Aspiration Biopsy Cytopathology 1St Edition 2020 , Tata Memorial Centre Textbook Of Oncology 1St Edition 2022 , Who Classification Of Tumours Ofhaematopoietic And Lymphoid Tissues 5Th Edition 2024 , Who Classification Of Thedigestive System 5Th Edition 2019 , Who Classification Ofcentral Nervous System 5Th Edition 2022 , Who Classification Of Tumours Ofthe Brest 4Th Edition 2019 , Who Tumours Of Theurinary System And Male Genital Organs 5Th Edition 2022 , Who Tumours Ofsoft Tissue And Bone 5Th Edition 2020 , Who Tumours Ofhead And Neck Tumours 5Th Edition 2023 , Who Tumours Ofendocrine Organs 5Th Edition 2025 , Who Tumours Of Theskin Tumours 4Th Edition 2018 , Who Tumours Of Thelung,Pleura,Thymus And Heart 5Th Edition 2020 , Who Classification Of Tumours Offemale Reproductive Organs 5Th Edition 2020 , Who Classification Of Tumours Ofthe Eye 4Th Edition 2018 , Department Of Paediatrics , Text Book Of Paediatric Cardiology Parks 7Th Edition Edition , Nelson’S Text Book Of Paediatric Kliegman 22Nd Edition , Fenichel’S Clinical Paediatric Neurology Ep Garaz , Kc James 9Th Edition , Neonatal- Prenatal Medicine Richard Martin A.A Fanaroff, Mc 12Th Edition , Smith’S Recognizable Patterns Of Human Malformation Kn Jones 8Th Edition , Ghai Essential Paediatric Vk Paul, Arvind Bhagga 10Th Edition , Manual Of Neonantal Care Cloherty & Stark 2Nd South East Asian Edition , Pg Text Book Of Paediatrics Piysush Gupta 3Rd Edition , Harriet Lane Hand Book Of Paediatrics Kleinman Mc Daniel, M Molley 23Rd Edition , Rudolph Text Book Of Paediatrics Rudolph 22Nd Edition , Paediatric Nephrology Rn Srivastava, Arvind Bhagga Latest , Paediatric Neurology Swaimann Latest , Haematology, Oncology Of Infancy & Childhood Nathan & Oski , Neonatology Text Book , Avery’S Diseases Of The Newborn A Gleason, S E Juul , Rennie & Robertson Neonatology , Iap Text Book Of Paediatrics A Parthasarathy , Rojjer Pediatric Intensive Care , Cloherty Neonatology , Department Of Pharmacology , 100 Cases In Clinical Pharmacology, Therapeutics And Prescribing Layne , Advanced Pharmacology Medhi , Clinical Applications Of Pharmacotherapy Brendon Krauss , Color Atlas Of Pharmacology: 5/E Lüllmann , Clinical Pharmacokinetics And Pharmacodynamics, 4/E Rowland , Concepts And Pharmaceutical Applications Of Antioxidants Nick Gilmour, , Drug Abuse Handbook 2Ed Karch , Drug Calculations Process And Problems For Clinical Practice With Cd-Rom 8 Brown , Aids Drugs For All Professor Ethan , Antihypertensive Drugs Mark Avis , Principles Of Good Clinical Practice (Pb) Mcgraw , Prescribing Drugs In Renal Diseases Kasi Viswesaran , Pocket Atlas Of Pharmacology ; 4/E, (Excl.Abc), Ie Luellmann , Pharmacognosy Patel , Pharmaceutics: Design And Manufacturing Of Medicines Brendon Krauss, , Nanomedicine And Drug Delivery Oscar Watson, , Liposome Technology : Entrapment Of Drugs And Other Materials Into Liposom Gregoriadis , Drug Delivery: Principles And Applications Brendon Krauss , Schizophrenia & Mood Disorders The Nre Drug Therapies In Clinical Practice Buckley , Steroids: Therapies And Applications Janet Hoffman , Study Of Crude Drugs (Pb) Iyengar , Therapeutic Drug Monitoring Dataa Concise Guide,4Th/Ed Das Gupta , Theory And Concepts Of Drug Carrier Systems Erica Helmer , Textbook Of Pharmaceutics Reginald Thornburg, , Textbook Of Drug Design And Discovery, 5/Ed Stromgaard , Practicals In Pharmacology Goyal , Practical Hplc Method Development, 2E (Pb) Snyder , Pharmacology For Health Professionals Ned Burnett, , Mcqs In Pharmacology Bhugra , Learning Practical Pharmacology For Undergraduates Sindhu Suyog , A Textbook Of Clinical Pharmacy Practice: Essential Concepts & Skills, 2Ed Parthasarathi , Calculation Of Drug Dosages: A Work Text, 10E Ogden , Modern Pharmacology With Clinical Applications, 6Th /Ed Craig , Principles Of Pharmacology 4Th/Edn David E. Golan , Antibiotic Basics For Clinicians (Sae Edn) Shrikala Baliga , Handbook Of Applied Therapeutics 9Th/Edn Sweet , Biomedical Research Jagadeesh , Lehne’S Pharmacology For Nursing Laura D. Rosenthal , Clinical Pharmacology By D.R Laurence D.R Laurence, Bennett, Brown , Department Of Physiology , Medical Physiology For Ug Students National Indu Khurana , Practical National Gk Pal , Physiology National Joshil’S , Review Of Physiology National Soumen Manna , Noble Lectures In Physiology National Jornvall , Basic Of Medical Physiology National Venkatesh , Text Book Of Practical Physiology National Varshney Bedi , Neurophysiology International Carpenter & Reddi , Brains Diseases Nervous System International Donaghy , Seldin And Giebischs The Kidney National Alpern Caplan , Essentials Of Exercise Physiology International Mcardle Katch , Harrisons Principles Of Internal Medicine International Jameson Fauci , Hutchisons Clinical Methods International Glunn Drake , Natters Essential Physiology International Mulroney Myers , Essentials Of Medical Pharmacology National Kd Tripathi , Biochemistry National U Satyanarayana , U Chakrapani , Davidsons Principles And Practice Of Medicine International Lan D Penman, Stuart H Ralston , Robbins And Kumar Basic Pathology National Vinnay Kumar Abas , Harrisons Endocrinilogy International J Larry Jameson , Diseases Of Ear, Nose And Throat National Pl Dhingra, Shruti Dhingra , Ghai Essential Pediatric National Vinod K Paul, Arvind Bagga , A Manual On Clinical Surgery National S Das , Dc Dutta’S Text Book Of Obstetrics National Hari Lal Konar , Shaw’S Text Book Of Gynaecology National Sunesh Kumar , Pathological Basis Of Diseases International Robbins & Cortan , Preventive And Social Medicine National K Park , Anatomy And Physiology Of Eye National Ak Khurana, Indu Khurana , Text Book Of Diagnostic Microbiology International Connie R Mahon Donald C Lehman , An Insiders Guide To Clinical Medicine National Archith Boloor Anudeep , Department Of Psychiatry , A Concise Handbook Of Community Psychiatry And Community Mental Health Leopaldbellack , A Manual Of Clinical Psychiatry , A Philosophy Of Suicide , A Short Textbook Of Psychiatry , Abc Of Psychological Medicine , Advances In Drug Therapy Of Mental Health , Adventure In Psychiatry , An A-Z Counseling Theory And Practice William Stewart , Barons’S Book On Psychology Baron , Basic Forensic Psychiatry Malcon Faulk , Basic Immunology Abul K Abbas , Bikkerstafs Neulogical Examination In Clinical Practice John Spillane , Child And Adolescent Psychiatry [Third Edition] Goodman R, S Scott , Children With Dyslexia Dushantkushwa , Clinical Management Of Memory Problems Barbara A.Wilson , Clinical Manual Of Psychosomatic Medicine: A Guide To Consultation-Liaison Psychiatry Kemuel L. Philbrick , Clinical Method In Psychiatry Vmd Namboodri , Clinical Neurology For Psychiatry David Myland Kaufmann , Clinical Practice Of Psychology C.Eugene Walker , Clinical Psychiatry Kenneth Granville-Grossman , Cognitive Behavioral Counselling In Action By Peter Trower, Jason Jones, Windy Dryden , Comprehensive Textbook Of Psychiatry Harold L.Kalpan , Counselling : A Comprehensive Profession (8Th Edition) , Current Diagnosis And Treatment: Psychiatry-2020 Micheal H Ebert[Lange] , Dementia Brice Pitt , Diagnostic And Statistical Manual Of Mental Disorders (Dsm-5®) American Psychiatric Association , Eeg And Seizure Semiology Basselabou Khalil , Epidemiological Methods In The Study Of Mental Disorders D.D. Reid , Epilepsy And The Family Richard Lechtenberd , Epilepsy In Clinical Practice Andrew N. Wilner , Essential Of Child Psychiatry Hm Connel , Essentials Of Psychiatry Bhatia , Fish’S Clinical Psychopathology Max Hamilton , Forensic Psychiatry Rosner , Fundamentals Of Human Neuropsychology Kolb And Wilson , Fundamentals Of Psychiatry Allan Tasman, Wanda K. Mohr , Fundamentals Of Psychopharmacology : Brain E. Leonard , Guidance And Counselling Dr. Sunita , Handbook Of Emergency Psychiatry Tirathsingh Gill , Handbook Of Epilepsy Thomas R Brown , Handbook Of Geriatric Psychiatry Ewald W. Busse. , Icd 10 Manual :Classification Of Mental & Behavioral Disorders Clinical Description & Diagnostic Guidelines Who , Impact Of Sexual Abuse On Mental Health Of Children’S Sibnath Deb , Indian Lunacy Act Rai Sahib B. R. Beotra , Insanity E.G.Younger , Introduction To Language Pathology David Crystal , Introduction To Psychology Cliffort T. Morgan , Introduction To Psychology Morgan , Introduction To Psychology Clifford Thomas Morgan, Richard Austin King, John R. Weisz, John Schopler , Kaplan And Sadocks Synopsis Of Psychiatry Benjamin J Saddock , Kaplon And Sadock’S Comprehensive Text Book Of Psychiatry 10Th Edition Benjamin J Saddock , Kaufmans Clinical Neurology For Psychiatrists David Myland Kaufman, Howard L. Geyer, Mark J Milstein , Language And Social Context David Copperfield , Learning &Behavior James E Mazur , Lishmans Organic Psychiatry Anthony S David , Lishmans Organic Psychiatry: A Textbook Of Neuropsychiatry William Alwynlishman , Lowinsonand Ruizs Substance Abuse: A Comprehensive Textbook Pedro Ruiz , Mastering Psychiatry : A Core Textbook For Undergraduates Zhang, Roger, Cyrus , Mental Health And Psychiatric Nursing Maya George , Mount Sinai Expert Guides: Psychiatry [2016] Simon, New, Goodman , Neuropsychological Assessment Of Neuropsychiatric Disorders Igor Grant , Neuropsychology A Clinical , Neuropsychology A Clinical Approach Kewinw.Walsh , New Oxford Text Book Of Psychiatry M.G. Gelder , Non Epileptic Seizures A.James Rowan , Organic Psychiatry William Alwynlishman , Oxford Handbook Of Psychiatry David Semple, ?Roger Smyth , Oxford Handbook On Addiction Medicine , Pain Psychological Perspectives Thomas Hadjistavreopouloskennethd.Craig , Personality Disorders Jeffery J. Magnavita , Phobia The Facts Donald W. Goodwin , Practical Psychiatry In Medicine John B Imboden , Principles Of Medical Genetics Thomas D Glelhrter , Problems Of Behavior In Children And Adolscents M.S.Bhatia , Psychiatric Drug Treatment Harold I Kaplon , Psychiatric Emergencies Andrew E Slabbey , Psychiatric Interview Shawn Christopher , Psychiatry Made Easy T Anbu , Psychological Testing Robert M. Kaplan , Psychotherapy & Medicine Schachter , Rehabilitation In Psychiatry Clephane Hume Ian Pullen , Rorschachs Test Samuel J. Beck , Rutters Child & Adolescent Psychiatry: [5Th Edition] Rutter M &Tayler E, , Schizophrenia Behavioral Aspects Kurt Salzinger , Shorter Oxford Textbook Of Psychiatry Philip Cowen, ?Paul Harrison, ?Tom Burns , Sigmunf Fraud The Interpretation Of Dreams Jmaesstarchay , Sims Symptoms In The Mind: Textbook Of Descriptive Psychopathology Femi Oyebode , Sleep A. Wauquier , Social Psychiatry Practice Maxxwell Jones , Stahls Essential Psychopharmacology: Neuroscientific Basis And Practical Applications [4Th Edition] S. M. Stahl, Stephen M. Stahl , Stress And The Art Of Biofeedback Barbara B Brown , Study Guide And Self Examination Review In Psychiatry Kaplan And Sadock , Teaching Psychiatry To Undergraduates Tom Brown, John Eagles , Temporal Lobe Epilepsy, Mania, & Schizophrenia & The Limbic System W.P. Koella Basel , Text Book Of Child And Adolescent Psychiatry [ 3Rd Edition] J M Weiner, M K Dulcan 2004 , Textbook Of Community Psychiatry Graham Thornicroft, George Szmukler , Textbook Of Psychiatric Nursing Bimlakapoor , Textbook Of Psychiatry Hendesson An Gillesoions , Textbook Of Psychiatry Tassman , The Life And Work Of Sigmund Volume 1, 2 & 3 Freud Johns , The Passion Of The Mind Irving Vallce , The Psychiatric Interview: Evaluation And Diagnosis Allan Tasman, Jerald Kay, Robert Ursano , Department Of Radiation Oncology , Perez & Brady’S Principles And Practice Of Radiation Oncology Lippinccott & William & Wilkins 8Th Edition , Leibel & Phillips : Text Book Of Radiation Oncology Elsevier 3Rd Edition , Fundamentals Of Radiation Oncology; Physical Biological & Clinical Aspects Elsevier 4Th Edition , Essentials Of Clinical Radiation Oncology Demos Medical /Springer Publishing 3Rd Edition , Basic Radiation Oncology Springer 2Nd Edition , Radiation Oncology: Principles, Precepts And Practice Vol -I & Ii Springer 2Nd Edition , Practical Radiation Oncology Springer 1St Edition , Form Radiobiology To Radiation Oncology Springer 1St Edition , Department Of Radiology , Grainger And Allisons – Diagnostic Radiology Essentials International Elsiver 2Nd Edition , Frcr Part 2A – Single Best Answer Questions International Anshan 1St Edition , Get Through Final Frcr 2A : Sba’S Teck Yew Chin International Crc Press 1St Edition , Succeeding In The New Frcr Part -2A Exam International Bpp 1St Edition , Grainger And Allisions Diagnostic Radiology International Elsevier 5Th Edition , Sba’S For The Fianal Frcr 2A Richard Lindsay International Oxford Univercity Press 1St Edition , Sba’S For The Frcr 2A S Currie International Cambridge Univercity Press 1St Edition , Final Frcr Part A Modules 1-3 Single Best Answer Mcqs International Redcliffe Publishing 1St Edition , Final Frcr Part A Modules 4-6 Single Best Answer International Redcliffe Publishing 1St Edition , Frcr Physics Mcqs In Clinical Radiology International Springer 1St Edition , Christensen’S Physics Of Diagnostic Radiology National Wolters Kulwer 4Th Edition , Text Book Of Radiographic Positioning And Related Anatomy International Elsevier 9Th Edition , Atlas Of Human Anatomy International Elsevier 7Th Edition , Radiography Physics Simplified National Evincepub Publishing 1St Edition , Clark’S Positioning In Radiography, A Stewart Whitley International Crc Press Taylor And Francis Group 13 Edition , Mri Made Easy National Jaypee Brothers Medical Pub Pvt Ltd. 3Rd Edition , Ct And Mri Protocol National Peepee Publications 3Rd Edition , Radiological Procedures National Arya Publications 12Th Edition , Radiological Science For Technologists International Elsevier 12Th Edition , Text Book Of Radiology For Residents And Technicians National Cbs Publishers & Distributers Pvt Ltd 6Th Edition , Principle And Practices Of Diagnostic Ultrasonography National Rimsmed Publications And Training 1St Edition , The Physics Of Radiology And Imaging National Jay Pee Pub. 1St Edition , Diagnostic Radiology Vol- 1,2,3 National Jay Pee 2Nd Edition , Core Radiology A Visual Approach To Diagnostic Imageing Vol- I,Ii International Cambridge 2Nd Edition , The Final Frcr Complete Revision International Crc Press Special Indian Edition , Practical Body Mri Protocols, Applications And Imaging Interpreter International Cambridge 1St Edition , Comprehensive Text Book Of Clinical Radiology- Volume Set International Elsevier 1St Edition , 101- Ct Abdodomen Solutions National Jk Brotherss Medical Publishers 1St Edition , Breast Elastography, Basic Principles & Interpreter Of Clinical Case National Jk Brothers Medical 1St Edition , Thieme Clinical Companions Ultrasound International Thieme Medical Publications 1St Edition , Direct Diagnosis In Radiology, Breast Imaging International Thieme 1St Edition , Direct Diagnosis In Radiology, Urogenital Imaging International , Champan & Nakielny’S Aids To Radiological Differential Diagnosis International Elsevier 7Th Edition , Mri Of The Musculoskeletal System International Thieme 2Nd Edition , Musculoskeletal Mri- A Case Approach To Interpretation And Reporting International Springer Latest Edition , Musculoskeletal Mri International Elsevier 3Rd Edition , Brain Imaging With Mri And Ct International Cambridge Latest Edition , Mri Of The Fetal Brain. Normal Development & Cerebal Pathologies International Springer Latest Edition , Diffusion Weight Mri Imaging Of The Brain International Springer Latest Edition , Liver Mri Correlation With Other Imaging Modalities And Histopathology International Springer 2Nd Edition , Mri Of The Levier A Practical Guide International Crc Press 2Nd Edition , Magnetic Resonance Imaging Clinics. Mri Imaging Of The Genitourinary System International Elsevier Latest Edition , Pediatric Urogential Radiology International Springer 3Rd Edition , Ultrasound Of The Urogential System International Thieme Latest Edition , Gynecological Imaging, A Reference Guide To Diagnosis International Springer Latest Edition , Imaging Of Gynecological Disorders In Infants And Children International Springer Latest Edition , Gynecologic Imaging, International Elsevier Latest Edition , Diagnostic Imaging Gynecology International Elsevier Latest Edition , Ultrasonography In Reproductive Medicine And Infertility International Cambridge Latest Edition , Hysterosalpingogrm Made Easy To Read International Elsevier Latest Edition , Imaging- Guide Interventions International Elsevier Latest Edition , Imaging Of Gynecological Disorders In Infants And Children International Springer Latest Edition , Department Of General Surgery , Bailey And Love’S Short Practice Of Surgery , Text Book Of Surgery By David C Sabistion , Text Book Of Operative Surgery , Clinical Methods- K Das , Recent Advances In Surgery By Taylor , A Applied Anatomy By Rj Last , Hamilition Bailey Demonstration Of Clinical Signs & Symptoms In Surgery , Emergency Surgery Byhamilton Baily , An Introduction To The Symptoms And Signs Of Surgical Diseases Norman Browse , Mastery Of Surgery By Josef Fisher , Maingot’S Abdominal Operations By Zinner , Oxford Text Book Of Surgery Vol-I,Ii & Iii By Morris And Wood , Acs Text Book Of Surgery , S Das Text Book On Surgical Short Case , Laparoscopic Surgery Technique- Darzi , Zollinger Atlas Of Surgical Operation , Department Of Orthopaedics , Essentials Of Orthopedic Surgery Sam W. Wiesel , Textbook Of Orthopedics John Ebnezar , Orthopedic Surgery For Students James Warren Sever , Orthopedic Surgery: Principles Of Diagnosis And Treatment Sam W. Wiesal& John N. Delahay , Orthopedic Surgery: The Essentials Mark Baratz, Anthony D. Watson, , Key Techniques In Orthopedic Surgery Steven H. Stern, Christopher M.Bono, And Mattew D. Saltzman , Insider’S Guide To Orthopedic Surgery , Orthopedics Of The Upper Limb James Chang , Orthopedics Of The Lower Limb Nicola Maffuli , Textbook Of Orthopedics And Trauma G.S. Kulkarni , Surgical Exposures In Orthopaedics: The Anatomic Approach Stanley Hoppenfeld, Piet De Boer, Richard Buckley , Orthopedics Surgical Approache Theodore I. Bowman, Anil K. Mani , Orthopedic Sports Medicine: Principles And Practice Jesse C. Delee, David Drez Jr. , Blood Centre , Essential Of Blood Banking National Jaypee , Text Book Of Blood Banking And Transfusion Medicine International Elsevier , Blood Banking And Transfusion Medicine International Churchill Civingzone , Modern Blood Banking And Transfusion Practice International F A Darin , Basic & Applied Concepts Of Blood Banking And Transfusion Practices International Wlsevier , Rossill’S Principles Of Transfusion Medicine International Willey- Blackwell , Standards For Blood Banks And Transfusion Services International Willey- Balckwell , The Text Book Of Blood Bank & Transfusion Medicine National Jay Pee , Manual Transfusion Medicine National Jay Pee , Hand Book Of Blood Banking & Transfusion Medicine National Jay Pee , Standards Operating Procedurs & Regulatory Guidelines ( Blood Banking) National Jay Pee , Blood Bank Transfusion Technology National Jay Pee , Blood Transfusion National Pub Med , Hematology, Transfusion And Cells Therapy National Pub Med , Department Of Cardiology/Cath Unit , Text Book Of Heart Diseases By Braunwalds , Text Book Of Cardiology By Hurst , Text Book Of Interventional Cardiology By Topol , Text Book Of Pediatric Cardiology By Moss & Adams , Text Book Of Interventioal Cardiology By Grossman , Perloff’S Text Book Pediatric Cardiology , Feigenbaum’S- Echocardiography , Echocardiography By Tajik & Otto , Ecg – Schmorth’S
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
36.
Drinking Water Supply and Sanitation #9891928 Technical Bid
Tender For Work Of Augmentation Of Rwss Singod Khurd To Provide Fhtc Including One Year Defect Liability Period Under Jjm In The Jurisdiction Of Phed Sub Division Govindgarh, District Rural Division -Ii, Jaipur. - 1 Construction of 200 mm dia Tube Well 2 Construction of tube well from ground level & up to 100 mtr depth to accommodate housing and assembly pipe of following sizes in all type of alluvium strataunconsolidated formation such as pebbles, boulders etc. by percussion/rotary drilling method as per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended up to date) and technical specifications, with gravel as per IS:4097-1967 and its packing as per IS: 2800 (Part I & II) 1979 as amended up to date (the work includes the cost of gravel & its primary packing and packing during development, lowering of housing & strainer assembly pipes with supply and wrapping of coir-rope, wherever necessary for arresting fine sand particles and development work, but excluding the cost of housing and strainer pipe assembly). The work would be completed after obtaining sand free water. 3 Nominal bore 200 mm dia. 4 Construction of tube well after completion of drilling by rotary /percussion method & up to 100 mtr. depthin all type of rocks by DTH systemas per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended up to date) and technical specifications. The workshall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe. 5 Nominal bore 200 mm dia. 6 Add 15% extra on above item (Item No 2.3.1 to 2.3.3) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr. 7 Add 30% extra on above item(Item No 2.3.1 to 2.3.3) for drilling depth beyond 200 mtr and from ground level, rate shall be applicable for only extra depth beyond 200 mtr . 8 Testing verticality of tube well by plumbing system and yield test and draw down test by pumping system as per IS : 2800 (Part – II) – 1979 or as per amended up to date. 9 Supplying & PackingP-gravel suitable for slot size/mesh size as suggested in IS 2800 (Part-1) 1991 or as per amended up to date. 10 Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to dateoffollowing sizes 11 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) 12 Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985. 13 200 mm dia nominal bore of 5.4mm thickness 14 Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. 15 Supply & Fixing tube well coverof MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2 (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. 16 200 mm dia 17 Supply & Installation of 3 phase ISI marked submersible motor pump set ofthree star or better rating of BEEand as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. 18 7.5 KW (10 HP) & head above 120 mtr. 19 Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes 20 80 mm dia 21 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 22 a) 80 mm 23 Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18 and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. 24 Above 5 HP and up to 10 HP 25 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 26 16 sq mm size, 4 core 27 Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended up to date of approved make including cost of all material andlabouras per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia. 28 80 mm dia 29 Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg.including all jointing material as per specification with safety cover. 30 Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. 31 50 mm dia 32 Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C.finished chamber covered with hinged type with locking arrangement C.I. Cover,C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. 33 Providing & Fixing pump safety cage as per specifications or as directed by Engineer in charge. 34 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. 35 3 core 4.0 Sq.mm 36 Providing & laying GI Pipe “A” (Light) class as per IS: 1239 pat 1: 2004 or amended upto date for casing pipe for submersible cable external work 40 mm dia complete in all respect. 37 Stand By Pump Set- Supplyof 3 phase ISI marked submersible motor pump set of five star rating by BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make offollowing duty condition with required accessories including makingconnection suitable for tube well/DCB. The job includes lowering ofmotor pump, installation of complete fitting & accessories, jointing ofelectrical cables up to switch board, testing of submersible pump set andinterconnection up to water mains, complete in all respect. 38 Up to 7.5 KW (10 HP) & head above 120 mtr. (203Nos) 39 Provision of Pumping Machinery 40 Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at synchronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected onC.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. 41 Centrifugal Monoblock Pump set (Single Stage) 42 15.0 KW (20.0 HP) 43 Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard.The pump set shall be suitable for direct coupling, with suitable suction strainer etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions of one of the makes approved by Technical Committee 44 1.0 HP 45 SITC STAR DELTA Starter type LT Panel of followingrating:all switchgears are of PHED approved makes, CRCA sheet of Panel enclosure is of TATA/ Essar 1.6mm/ 2.0mm thick duly Electrostatic Powder Coated with angle frame including other ancillaries ( Insulators, Acrylic Sheet , Backlight Sheet, Hardware, Wire, Name Plates, Lugs, Pvc Channel , Mcb Chanel , Lock, Hing , Bidding , Connectors, Neutral Links , Spiral , Saddle & Packing Material ) etc. and 100A/ 125A ,TPN, Aluminium Bus Bar with Colour coated heat shrinkage sleeves complete as per Technical Specifications and as per direction of Engineer-In-Charge. 46 STAR DELTA STARTER15.0 KW (20.0 HP) :For 2 motors (1 W+ 1S) I/C- MCCB 100A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 100/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3)and O/G-MCCB 63A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (2), Power Cont 32A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (12-18A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Priventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 7.5Kvar (2), S/D Timer(2) 47 Providing, lowering,aligning, fixing inposition inpipe line, CI D/F Sluice valves straightandpocketlessbodypassageofapprovedmakeof following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - AISI- 410 ,Body Seat ring, Wedge facingring&Bushes-LTB2/SS ,FacetofacedimensionsasperIS14846/2000 (amendeduptodate),Epoxy(Non-Toxic-suitablefordrinkingwater)applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 andIS:1367/CS/galvanisedsteel InsertionrubberofblackEPDM6mmthick. Sluice valves including all jointing & jointing material, labour, testing and commissioningalongwithpipelineasperTechnicalSpecificationsandasper direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 48 Manually Operated CI Sluice valve of Class PN-1.0 49 150 mm HW 50 200 mm HW 51 Providing,lowering,laying,aligning,fixinginpositionandjointingCIdismantling joint(SuitableforSluicevalvesetc.)asperISspecifications complete of the following sizes including alljointingmaterial, cost of all labour, testing and commissioning Technical Specifications and as per directionof Engineer.Class PN 1.0 52 150 mm dia. 53 200 mm dia. 54 Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths DI standard specials with rubber ring (EPDM)/ nut bolt and insertion sheet and jointing as per IS: 9523-2000 or as amended up to date, such as tees, bends, tapers, caps etc. within trenches in DI pipe line complete including all material, labour, taxes, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge (excluding earth work). 55 A/S Tee , Bend, Reducer (All End Socketed) 56 Upto 300 mm Diameter 57 Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amendedup to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/316 & shaft bearings-bronze/ PTET or Teflon with EPDM/NBR O ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 58 Class PN 1.6, Manually Operated with Gear 59 150 mm dia 60 Providing, lowering, aligning, fixing in position in pipe line, DIdouble flanged resilient seated Dual plate check valve of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside .Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/410 , Hinge SS AISI 316/304,SpringSS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR O ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick .Suitablesupport structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 61 Class PN 1.6 62 150 mm dia 63 Providing,lowering,aligning,fixinginpositionandJointinginpipeline,CIBody FlangedEndTamperproof KineticAirValveofapprovedmakesoffollowing pressureratinganddia and as per followingspecifications: Governingstandard - AWWA C512/ IS:14845:2000(amended up to date),Body, High pressure cover , Low pressure cover, Cowl andJoint support ring - Grey cast iron of grade IS:210/FG200,Float-LPball&HPball:AISI304stainlessSteel,FloatGuide-HTB1,Seatring& Gasket - EPDM/NBR, HP Orifice & HP orifice plug : HTB2/ SS ,Bush: Bronze , Flanges as per IS/ BS, Drilled as per IS:1538.Epoxy paint (Non-Toxic & suitable for drinking water)appliedonbody&cover insideandoutsideFasteners-CS/Galvanised steel,OutletofbigorificewillhaveascreentopreventTamperoffloat,withCI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amended up to date)PN1.0ratingsValvesincludingallmaterial,labour,testingand commissioningasperTechnicalSpecificationsandas perdirectionofEngineerin charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. 64 Class PN 1.0 65 50 mm 66 SITC of Bulk Flow Meter with removable mechanism class B confirming to ISO:4064:2005/ IS: 2373of approved make of following dia sized pipelines andspecificationscomplete: Media:Water(Clear),Temp.50deg.,Pr. rating:PN16,Protectiontype:IP-68, BodyMaterial:IS-210Gr.FG-200, AccuracyClass:ClassB(±2%@Nominalflowrate),MagneticDrive, Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In- Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. 67 BFM 150 mm 68 Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg. including all jointing material as per specification with safety cove 69 Provision of Reserviours 70 Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: - 71 a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc.c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR.The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil.d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall.e)Conducting successfully hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome.g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc..h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab.j) Providing and fixing water level indicator (float type). 72 k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres.l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide.m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall).n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground.o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm.p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir.q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. 73 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-III & STAGING 20 M 74 100 KL capacity 75 200KL capacity 76 Construction of RCC (Flat slab type) Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: - 77 a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase.c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall.e) Successful hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the roof Slab.g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. 78 h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type).i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide.k) Providing and fixing of 150mm wide water bar for the construction joints in the container.l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir.m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. 79 Rates for RCC Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2,3 & 4 80 150KL capacity 81 Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctileIron(DI)ISI markedK-9 gradeS&Spipesas per IS:8329-2000 (amendedup todate),withinternalcementmortar lining suitable for potablewater with rubber ring (EPDM)joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work)Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. 82 100 mm 83 150 mm 84 200 mm 85 Providing, lowering,aligning, fixing inposition inpipe line, CI D/F Sluice valves straightandpocketlessbodypassageofapprovedmakeof following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - AISI- 410 ,Body Seat ring, Wedge facingring&Bushes-LTB2/SS ,FacetofacedimensionsasperIS14846/2000 (amendeduptodate),Epoxy(Non-Toxic-suitablefordrinkingwater)applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 andIS:1367/CS/galvanisedsteel InsertionrubberofblackEPDM6mmthick. Sluice valves including all jointing & jointing material, labour, testing and commissioningalongwithpipelineasperTechnicalSpecificationsandasper direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 86 Manually Operated CI Sluice valve of Class PN-1.0 87 100 mm HW 88 150 mm HW 89 200 mm HW 90 Providing,lowering,laying,aligning,fixinginpositionandjointingCIdismantling joint(SuitableforSluicevalvesetc.)asperISspecifications complete of the following sizes including alljointingmaterial, cost of all labour, testing and commissioning Technical Specifications and as per directionof Engineer.Class PN 1.0 91 100 mm dia. 92 150 mm dia. 93 200 mm dia. 94 Providing,lowering,aligning,fixinginpositionandJointinginpipeline,CIBody FlangedEndTamperproof KineticAirValveofapprovedmakesoffollowing pressureratinganddia and as per followingspecifications: Governingstandard - AWWA C512/ IS:14845:2000(amended up to date),Body, High pressure cover , Low pressure cover, Cowl andJoint support ring - Grey cast iron of grade IS:210/FG200,Float-LPball&HPball:AISI304stainlessSteel,FloatGuide-HTB1,Seatring& Gasket - EPDM/NBR, HP Orifice & HP orifice plug : HTB2/ SS ,Bush: Bronze , Flanges as per IS/ BS, Drilled as per IS:1538.Epoxy paint (Non-Toxic & suitable for drinking water)appliedonbody&cover insideandoutsideFasteners-CS/Galvanised steel,OutletofbigorificewillhaveascreentopreventTamperoffloat,withCI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amended up to date)PN1.0ratingsValvesincludingallmaterial,labour,testingand commissioningasperTechnicalSpecificationsandas perdirectionofEngineerin charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. 95 Class PN 1.0 96 50 mm 97 Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths DI standard specials with rubber ring (EPDM)/ nut bolt and insertion sheet and jointing as per IS: 9523 :2000 oramended upto date such as tees, bends, tapers, caps etc. within trenches in DI pipe line complete including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. (excluding earth work).A/F Tee, Bend, Reducer (All End Flanged)Upto 300 mm dia 98 SITC of Bulk Flow Meter with removable mechanism class B confirming to ISO:4064:2005/ IS: 2373of approved make of following dia sized pipelines andspecificationscomplete: Media:Water(Clear),Temp.50deg.,Pr. rating:PN16,Protectiontype:IP-68, BodyMaterial:IS-210Gr.FG-200, AccuracyClass:ClassB(±2%@Nominalflowrate),MagneticDrive, Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In- Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. 99 BFM 150 mm 100 BFM200 mm 101 Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15as leveling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as perspecifications and standard drawings and as directed by Engineer-in-Charge. 102 Sluice valve chamber of size1.17m x0.95m x1.37mfor pipe size-from 125-to-150mm 103 Provision of Rising Main 104 Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctileIron(DI)ISI markedK-7gradeS&Spipesas per IS:8329-2000 (amendedup todate),withinternalcementmortar lining suitable for potablewater with rubber ring (EPDM)joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. 105 100mm diameter 106 150mm diameter 107 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended up to date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. 108 HDPE PE-80 PN-10 109 90 mm HDPE 110 110 mm HDPE 111 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended up to date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply of pipe shall be in straight length in 6/12 M. 112 HDPE PE-80PN-10 113 125 mm HDPE 114 140 mm HDPE 115 160 mm HDPE 116 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil 117 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 118 Manually Operated CI Sluice valve of Class PN-1.0 119 80 mm HW 120 100 mm HW 121 150 mm HW 122 Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specificationscompleteofthefollowingsizesincludingall jointing material,costofalllabour,testingandcommissioning Technical Specifications and as per direction of Engineer. Class PN 1.0 123 80 mm dia 124 100 mm dia. 125 150 mm dia. 126 Providing,lowering,aligning,fixinginpositionandJointinginpipeline,CIBody FlangedEndTamperproof KineticAirValveofapprovedmakesoffollowing pressureratinganddia and as per followingspecifications: Governingstandard - AWWA C512/ IS:14845:2000(amended up to date),Body, High pressure cover , Low pressure cover, Cowl andJoint support ring - Grey cast iron of grade IS:210/FG200,Float-LPball&HPball:AISI304stainlessSteel,FloatGuide-HTB1,Seatring& Gasket - EPDM/NBR, HP Orifice & HP orifice plug : HTB2/ SS ,Bush: Bronze , Flanges as per IS/ BS, Drilled as per IS:1538.Epoxy paint (Non-Toxic & suitable for drinking water)appliedonbody&cover insideandoutsideFasteners-CS/Galvanised steel,OutletofbigorificewillhaveascreentopreventTamperoffloat,withCI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amended up to date)PN1.0ratingsValvesincludingallmaterial,labour,testingand commissioningasperTechnicalSpecificationsandas perdirectionofEngineerin charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. 127 Class PN 1.0 128 40 mm 129 Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15as leveling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as perspecifications and standard drawings and as directed by Engineer-in-Charge. 130 For Class-A loading 131 Sluice valve chamber of size1.13m x0.85m x1.27m for pipe size-upto100mm 132 Sluice valve chamber of size1.17m x0.95m x1.415m for pipe size-from 125-to-150mm 133 Construction of RCC pillar for following size of air valves including earthwork excavation,RCC M25 grade for base slab, vertical pillar, including cost of steel reinforcement ,GI (class-B)/MS vertical pipe, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as directed by Engineer. 134 Air valve pillarfor airvalves size of 80mmdia 135 Distribution Main 136 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended up to date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. 137 HDPE PE-80PN-6 138 75 mm dia 139 90 mm dia 140 110 mm dia 141 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended up to date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply of pipe shall be in straight length in 6/12 M. 142 HDPE PE-80PN-6 143 125 mm dia 144 140 mm dia 145 160 mm dia 146 180 mm dia 147 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil 148 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 149 Manually Operated CI Sluice valve of Class PN-1.0 150 80 mm HW 151 100 mm HW 152 125 mm HW 153 150 mm HW 154 Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI single Air ValveFlanged/ Screwed type of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amendedup to date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float StainlessSteelAISI304/IS:3444,FloatGuide-HBT1,Bodyseatring-Leadedtin bronze/ SS , Seal ring and face ring - EPDM/NBR, Ends flanged according to IS 6418 orScrewed type shall have external pipe threads conforming to IS 554Fasteners - CSEpoxypaintinsideoutsideoffoodgradesafefordrinkingwater,Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. 155 Class PN 1.0 156 25 mm S-1 Type 157 40 mm S-1 Type 158 Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15as leveling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as perspecifications and standard drawings and as directed by Engineer-in-Charge. 159 For Class-AA loading 160 Sluice valve chamber of size 1.13 m x0.85 m x1.325 m-for pipe size-upto 100 mm 161 Sluice valve chamber of size 1.17m x 0.95m x1.47mfor pipe size-from 125-to-150mm 162 Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. 163 Dismantling of flexible pavement for pipe line line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work. 164 bituminous road (average thickness 300 mm) 165 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smoothwheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening & binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per MoRD Specification Clause 405. 166 Grading II (Using Screening Crushable type) 167 By Mechanical Means 168 Providingandlayinginpositioncementconcreteinspecifiedgradeover prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line andchamberwork.MeasurementforCCworktobemade asperstandard trenchwidthspecifiedintenderdocumentandnoextrapaymentshallbe madebemadefortrenchwidthmorethanspecified, completeworkasper technical specification and scope of work. 169 M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). 170 Removing& Re-fixing of Precast concrete interlocking blocks for laying of pipe linebymanualmethod,stackingofserviceable&nonserviceablematerial separately, disposal of dismantled material lead upto 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub baseasdefined.Completejobistobeexecutedasperthedirectionsof Engineer in charge. The rates to be inclusive of fixing of minimum 70 percent reusable precast concrete interlockingblock and cost of required new precast concrete interlocking block against damaged, including alllead and lift as per Technicalspecifications. (Interlockingblockmanufacturedbyfully computerizedautomaticstationeryhydraulicvibropressedmachine&full computerizedautomaticbatchingplantofclassA-1asperBS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm) 171 80 mm thick. 172 Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specificationscompleteofthefollowingsizesincludingall jointing material,costofalllabour,testingandcommissioning Technical Specifications and as per direction of Engineer. Class PN 1.0 173 80 mm dia 174 100 mm dia. 175 125 mm dia. 176 150 mm dia. 177 Survey by Electronic Total station/DGPS of villages with a view of preparing village index plan indicating roads/ streets, surface and width of road/ streets along with places of importance such as Panchayat Bhawan, Hospital, School, Post office, Temple Water Supply structures (GLRs, PSPs, pumping station physical boundary of village north etc. including levels at some important points as per instruction of engineer in charge.Hydraulic Design of Distribution network in Loop/Water Gem/EPANET or any other compatible software. Preparation of Auto CAD Drawing (A-3/A-2) with complete hydraulic design out put details, such as pipe no, node no, pipe length, pressure at node etc. Submission of three sets of colour print prepared in Auto CAD.For Length Up to 2.5 KM 178 Rate for length up to 2.5 km 179 Add extra for length more than 2.5 km 180 PUMP HOUSE AND BOUNDRY WALL 181 Construction of Pump house of required size suitable for installation of maximum 4 no. monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement. 182 Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonary in CM: 1:6 section of foundation above PCC,600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D) 4. Superstructure work: Stone masonary in CM: 1:6, W-300, height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6.6. Expansion joint shall be on every 30 mtr.7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done. 183 Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints. 184 Provision of water harvesting 185 Supply of strainer pipes made of ERWM.S.black pipe ISI Marked of following size at the site of work including required size of slotting as per IS : 8110-1985.(Item no. 4.6.2 PWD BSR ) 200 mm dia nominal bore 186 Excavation including loading, unloading, disposal and dressing of excavatedearth within initial lead of 50m and lift up to 1.5m including dressing ofexcavated area and dewatering wherever required complete in all respect. Hard / dense soil (Item no. 1(b) WRD BSR ) 187 Filter 188 Providingandlayinginpositioncementconcreteinspecifiedgradeover prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line andchamberwork.MeasurementforCCworktobemade asperstandard trenchwidthspecifiedintenderdocumentandnoextrapaymentshallbe madebemadefortrenchwidthmorethanspecified, completeworkasper technical specification and scope of work. 189 M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). (4.8 PHED 2022) 190 सेन्‍टरिंगशटरिंग (तख्ता एवम ढुलाबंदी) का आर.सी.सी. छत, स्‍लेब, छज्‍जे, लिन्‍टल आदि डालने के लिए लगाना 4.5 मीटर ऊचाई तक के लिए तथा हटाना आदि विशेष विवरण के अनुसार। शटरिंग स्टील CykWd Lrjh; nj vuqlwph 2021 iapk;r lfefr [k.Mkj ds vuqlkj dz-la- 93 c 191 Filter 192 आर.सी.सी. काम के लिए लोहे को काटना] मोड़ना तथा स्‍थान पर लगाना तथा बांधने का कार्य मय आपूर्ति के ।CykWd Lrjh; nj vuqlwph 2021 iapk;r lfefr [k.Mkj ds vuqlkj dz-la- 61 193 Supply & lowering air line of 25mm dia, G.I. pipe B class having perforation 3 to 5mm size all arrow of G.I. pipe in Zig-Zag fashion & making air vent at top including the cost of Tee-Nipples, Elbow, Socket etc.(Item no. 4.22 PWD BSR ) 194 40 मि.मी.नामीय माप की क्रेशर रोड़ी कार्य स्थल पर ( CykWd Lrjh; nj vuqlwph 2021 iapk;r lfefr [k.Mkj ds vuqlkj dz-la-- 136 C) 195 20 मि.मी.नामीय माप की क्रेशर रोड़ी कार्य स्थल पर ( CykWd Lrjh; nj vuqlwph 2021 iapk;r lfefr [k.Mkj ds vuqlkj dz-la- 136 D) 196 12/10/6 मि.मी.नामीय माप की क्रेशर रोड़ी कार्य स्थल पर ( CykWd Lrjh; nj vuqlwph 2021 iapk;r lfefr [k.Mkj ds vuqlkj dz-la- 136 E) 197 Sand GKN BSR 2019(Material Item No. 5.5) 198 Filter 199 Supply & fixing tube well cover of MS sheet (6 mm thick) with nuts & bolts complete for casing size 200 mm(Item no. 4.8.4 PWD BSR ) 200 S & F M.S. clamp, set of 50 ×6mm flat iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set(PWD BSR 2019 Item No. 4.9) 201 Provision of Household Connection 202 Providing Household Tap Connectionas per technical specification andapproved drawing and as per relevant IS code (amended up to date) from HDPE pipe line up to consumer meter/premises by using electro fusion saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance withspecification for potable water including electrofusion saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valve and specials, below ground level 20 mm nominal dia MDPE pipe PE80 PN 16 as per ISO 4427 / 20 mm nominaldia PPR-C (Three layered) pipePN16 SDR 7.4 (IS:15801:2008) (ISI mark) for and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipes with fittings in the premises for fixing a tap / meterbox (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level.Note: Road cut and restoration is not part of this item and paid seperately. 203 Average length up to 05 mtr 20 mm dia MDPE pipe/ 15 mm GI class B pipe 204 Add extra over item no 1.21 & 1.22 for providing20 mm PE80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr. 205 Road cutting for house hold service connection in minimum trench width wherever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be doneby using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge.. 206 Survey of all properties, preparation of GIS based consumer mapping of consumer water connectiondatabase, plotting assets on GIS map etc (Satellite image will be provided by the Department) 207 Data entry of existing FHTCs in rural area under JJM on website ejalshakti.gov.in; work includes visiting the village for collecting basic data consumers likei.e. Aadhar no./ration card/voter ID/BPL card/ PAN card/driving licence/passport/Antyodaya card/mobile no. etc. and entering the details on the above website. The cost also includes computer and operator.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 11
37.
Drinking Water Supply and Sanitation #9876390 Technical Bid
Tender For Work Of Augmentation Of Rwss Loharwada To Provide Fhtc Including One Year Defect Liability Period Under Jjm In The Jurisdiction Of Phed Sub Division Govindgarh, District Rural Division -Ii, Jaipur - 1 Construction of 200 mm dia Tube Well 2 Construction of tube well from ground level & up to 100 mtr depth to accommodate housing and assembly pipe of following sizes in all type of alluvium strataunconsolidated formation such as pebbles, boulders etc. by percussion/rotary drilling method as per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended up to date) and technical specifications, with gravel as per IS:4097-1967 and its packing as per IS: 2800 (Part I & II) 1979 as amended up to date (the work includes the cost of gravel & its primary packing and packing during development, lowering of housing & strainer assembly pipes with supply and wrapping of coir-rope, wherever necessary for arresting fine sand particles and development work, but excluding the cost of housing and strainer pipe assembly). The work would be completed after obtaining sand free water. 3 Nominal bore 200 mm dia. 4 Construction of tube well after completion of drilling by rotary /percussion method & up to 100 mtr. depthin all type of rocks by DTH systemas per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended up to date) and technical specifications. The workshall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe. 5 Nominal bore 200 mm dia. 6 Add 15% extra on above item (Item No 2.3.1 to 2.3.3) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr. 7 Add 30% extra on above item(Item No 2.3.1 to 2.3.3) for drilling depth beyond 200 mtr and from ground level, rate shall be applicable for only extra depth beyond 200 mtr . 8 Testing verticality of tube well by plumbing system and yield test and draw down test by pumping system as per IS : 2800 (Part – II) – 1979 or as per amended up to date. 9 Supplying & PackingP-gravel suitable for slot size/mesh size as suggested in IS 2800 (Part-1) 1991 or as per amended up to date. 10 Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to dateoffollowing sizes 11 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) 12 Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985. 13 200 mm dia nominal bore of 5.4mm thickness 14 Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. 15 Supply & Fixing tube well coverof MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2 (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. 16 200 mm dia 17 Supply & Installation of 3 phase ISI marked submersible motor pump set ofthree star or better rating of BEEand as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. 18 7.5 KW (10 HP) & head above 120 mtr. 19 Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes 20 80 mm dia 21 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 22 a) 80 mm 23 Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18 and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. 24 Above 5 HP and up to 10 HP 25 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 26 16 sq mm size, 4 core 27 Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended up to date of approved make including cost of all material andlabouras per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia. 28 80 mm dia 29 Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg.including all jointing material as per specification with safety cover. 30 Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. 31 50 mm dia 32 Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C.finished chamber covered with hinged type with locking arrangement C.I. Cover,C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. 33 Providing & Fixing pump safety cage as per specifications or as directed by Engineer in charge. 34 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. 35 3 core 4.0 Sq.mm 36 Providing & laying GI Pipe “A” (Light) class as per IS: 1239 pat 1: 2004 or amended upto date for casing pipe for submersible cable external work 40 mm dia complete in all respect. 37 Stand By Pump Set- Supplyof 3 phase ISI marked submersible motor pump set of five star rating by BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make offollowing duty condition with required accessories including makingconnection suitable for tube well/DCB. The job includes lowering ofmotor pump, installation of complete fitting & accessories, jointing ofelectrical cables up to switch board, testing of submersible pump set andinterconnection up to water mains, complete in all respect. 38 Up to 7.5 KW (10 HP) & head above 120 mtr. (203Nos) 39 Provision of Pumping Machinery 40 Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at synchronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected onC.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. 41 Centrifugal Monoblock Pump set (Single Stage) 42 15 KW (20 HP) 43 Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard.The pump set shall be suitable for direct coupling, with suitable suction strainer etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions of one of the makes approved by Technical Committee 44 1.0 HP 45 SITC STAR DELTA Starter type LT Panel of followingrating:all switchgears are of PHED approved makes, CRCA sheet of Panel enclosure is of TATA/ Essar 1.6mm/ 2.0mm thick duly Electrostatic Powder Coated with angle frame including other ancillaries ( Insulators, Acrylic Sheet , Backlight Sheet, Hardware, Wire, Name Plates, Lugs, Pvc Channel , Mcb Chanel , Lock, Hing , Bidding , Connectors, Neutral Links , Spiral , Saddle & Packing Material ) etc. and 100A/ 125A ,TPN, Aluminium Bus Bar with Colour coated heat shrinkage sleeves complete as per Technical Specifications and as per direction of Engineer-In-Charge. 46 STAR DELTA STARTER15.0 KW (20.0 HP) :For 2 motors (1 W+ 1S) I/C- MCCB 100A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 100/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3)and O/G-MCCB 63A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (2), Power Cont 32A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (12-18A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Priventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 7.5Kvar (2), S/D Timer(2) 47 Providing, lowering,aligning, fixing inposition inpipe line, CI D/F Sluice valves straightandpocketlessbodypassageofapprovedmakeof following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - AISI- 410 ,Body Seat ring, Wedge facingring&Bushes-LTB2/SS ,FacetofacedimensionsasperIS14846/2000 (amendeduptodate),Epoxy(Non-Toxic-suitablefordrinkingwater)applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 andIS:1367/CS/galvanisedsteel InsertionrubberofblackEPDM6mmthick. Sluice valves including all jointing & jointing material, labour, testing and commissioningalongwithpipelineasperTechnicalSpecificationsandasper direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 48 Manually Operated CI Sluice valve of Class PN-1.0 49 150 mm HW 50 200 mm HW 51 Providing,lowering,laying,aligning,fixinginpositionandjointingCIdismantling joint(SuitableforSluicevalvesetc.)asperISspecifications complete of the following sizes including alljointingmaterial, cost of all labour, testing and commissioning Technical Specifications and as per directionof Engineer.Class PN 1.0 52 150 mm dia. 53 200 mm dia. 54 Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths DI standard specials with rubber ring (EPDM)/ nut bolt and insertion sheet and jointing as per IS: 9523-2000 or as amended up to date, such as tees, bends, tapers, caps etc. within trenches in DI pipe line complete including all material, labour, taxes, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge (excluding earth work). 55 A/S Tee , Bend, Reducer (All End Socketed) 56 Upto 300 mm Diameter 57 Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amendedup to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/316 & shaft bearings-bronze/ PTET or Teflon with EPDM/NBR O ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 58 Class PN 1.6, Manually Operated with Gear 59 150 mm dia 60 Providing, lowering, aligning, fixing in position in pipe line, DIdouble flanged resilient seated Dual plate check valve of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside .Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/410 , Hinge SS AISI 316/304,SpringSS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR O ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick .Suitablesupport structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 61 Class PN 1.6 62 150 mm dia 63 Providing,lowering,aligning,fixinginpositionandJointinginpipeline,CIBody FlangedEndTamperproof KineticAirValveofapprovedmakesoffollowing pressureratinganddia and as per followingspecifications: Governingstandard - AWWA C512/ IS:14845:2000(amended up to date),Body, High pressure cover , Low pressure cover, Cowl andJoint support ring - Grey cast iron of grade IS:210/FG200,Float-LPball&HPball:AISI304stainlessSteel,FloatGuide-HTB1,Seatring& Gasket - EPDM/NBR, HP Orifice & HP orifice plug : HTB2/ SS ,Bush: Bronze , Flanges as per IS/ BS, Drilled as per IS:1538.Epoxy paint (Non-Toxic & suitable for drinking water)appliedonbody&cover insideandoutsideFasteners-CS/Galvanised steel,OutletofbigorificewillhaveascreentopreventTamperoffloat,withCI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amended up to date)PN1.0ratingsValvesincludingallmaterial,labour,testingand commissioningasperTechnicalSpecificationsandas perdirectionofEngineerin charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. 64 Class PN 1.0 65 50 mm 66 SITC of Bulk Flow Meter with removable mechanism class B confirming to ISO:4064:2005/ IS: 2373of approved make of following dia sized pipelines andspecificationscomplete: Media:Water(Clear),Temp.50deg.,Pr. rating:PN16,Protectiontype:IP-68, BodyMaterial:IS-210Gr.FG-200, AccuracyClass:ClassB(±2%@Nominalflowrate),MagneticDrive, Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In- Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. 67 BFM 150 mm 68 Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg. including all jointing material as per specification with safety cove 69 Provision of Reserviours 70 Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: - 71 a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc.c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR.The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil.d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall.e)Conducting successfully hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome.g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc..h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab.j) Providing and fixing water level indicator (float type). 72 k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres.l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide.m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall).n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground.o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm.p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir.q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. 73 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-III & STAGING 20 M 74 100 KL capacity 75 250KL capacity 76 Construction of RCC (Flat slab type) Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: - 77 a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase.c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall.e) Successful hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the roof Slab.g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. 78 h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type).i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide.k) Providing and fixing of 150mm wide water bar for the construction joints in the container.l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir.m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. 79 Rates for RCC Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2,3 & 4 80 100KL capacity 81 Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctileIron(DI)ISI markedK-9 gradeS&Spipesas per IS:8329-2000 (amendedup todate),withinternalcementmortar lining suitable for potablewater with rubber ring (EPDM)joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work)Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. 82 100 mm 83 150 mm 84 200 mm 85 Providing, lowering,aligning, fixing inposition inpipe line, CI D/F Sluice valves straightandpocketlessbodypassageofapprovedmakeof following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - AISI- 410 ,Body Seat ring, Wedge facingring&Bushes-LTB2/SS ,FacetofacedimensionsasperIS14846/2000 (amendeduptodate),Epoxy(Non-Toxic-suitablefordrinkingwater)applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 andIS:1367/CS/galvanisedsteel InsertionrubberofblackEPDM6mmthick. Sluice valves including all jointing & jointing material, labour, testing and commissioningalongwithpipelineasperTechnicalSpecificationsandasper direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 86 Manually Operated CI Sluice valve of Class PN-1.0 87 100 mm HW 88 150 mm HW 89 200 mm HW 90 Providing,lowering,laying,aligning,fixinginpositionandjointingCIdismantling joint(SuitableforSluicevalvesetc.)asperISspecifications complete of the following sizes including alljointingmaterial, cost of all labour, testing and commissioning Technical Specifications and as per directionof Engineer.Class PN 1.0 91 100 mm dia. 92 150 mm dia. 93 200 mm dia. 94 Providing,lowering,aligning,fixinginpositionandJointinginpipeline,CIBody FlangedEndTamperproof KineticAirValveofapprovedmakesoffollowing pressureratinganddia and as per followingspecifications: Governingstandard - AWWA C512/ IS:14845:2000(amended up to date),Body, High pressure cover , Low pressure cover, Cowl andJoint support ring - Grey cast iron of grade IS:210/FG200,Float-LPball&HPball:AISI304stainlessSteel,FloatGuide-HTB1,Seatring& Gasket - EPDM/NBR, HP Orifice & HP orifice plug : HTB2/ SS ,Bush: Bronze , Flanges as per IS/ BS, Drilled as per IS:1538.Epoxy paint (Non-Toxic & suitable for drinking water)appliedonbody&cover insideandoutsideFasteners-CS/Galvanised steel,OutletofbigorificewillhaveascreentopreventTamperoffloat,withCI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amended up to date)PN1.0ratingsValvesincludingallmaterial,labour,testingand commissioningasperTechnicalSpecificationsandas perdirectionofEngineerin charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. 95 Class PN 1.0 96 50 mm 97 Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths DI standard specials with rubber ring (EPDM)/ nut bolt and insertion sheet and jointing as per IS: 9523 :2000 oramended upto date such as tees, bends, tapers, caps etc. within trenches in DI pipe line complete including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. (excluding earth work).A/F Tee, Bend, Reducer (All End Flanged)Upto 300 mm dia 98 SITC of Bulk Flow Meter with removable mechanism class B confirming to ISO:4064:2005/ IS: 2373of approved make of following dia sized pipelines andspecificationscomplete: Media:Water(Clear),Temp.50deg.,Pr. rating:PN16,Protectiontype:IP-68, BodyMaterial:IS-210Gr.FG-200, AccuracyClass:ClassB(±2%@Nominalflowrate),MagneticDrive, Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In- Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. 99 BFM 150 mm 100 BFM200 mm 101 Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15as leveling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as perspecifications and standard drawings and as directed by Engineer-in-Charge. 102 Sluice valve chamber of size1.17m x0.95m x1.37mfor pipe size-from 125-to-150mm 103 Provision of Rising Main 104 Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctileIron(DI)ISI markedK-7gradeS&Spipesas per IS:8329-2000 (amendedup todate),withinternalcementmortar lining suitable for potablewater with rubber ring (EPDM)joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. 105 100mm diameter 106 150mm diameter 107 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended up to date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. 108 HDPE PE-80 PN-10 109 90 mm HDPE 110 110 mm HDPE 111 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended up to date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply of pipe shall be in straight length in 6/12 M. 112 HDPE PE-80PN-10 113 125 mm HDPE 114 140 mm HDPE 115 160 mm HDPE 116 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil 117 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 118 Manually Operated CI Sluice valve of Class PN-1.0 119 80 mm HW 120 100 mm HW 121 150 mm HW 122 Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specificationscompleteofthefollowingsizesincludingall jointing material,costofalllabour,testingandcommissioning Technical Specifications and as per direction of Engineer. Class PN 1.0 123 80 mm dia 124 100 mm dia. 125 150 mm dia. 126 Providing,lowering,aligning,fixinginpositionandJointinginpipeline,CIBody FlangedEndTamperproof KineticAirValveofapprovedmakesoffollowing pressureratinganddia and as per followingspecifications: Governingstandard - AWWA C512/ IS:14845:2000(amended up to date),Body, High pressure cover , Low pressure cover, Cowl andJoint support ring - Grey cast iron of grade IS:210/FG200,Float-LPball&HPball:AISI304stainlessSteel,FloatGuide-HTB1,Seatring& Gasket - EPDM/NBR, HP Orifice & HP orifice plug : HTB2/ SS ,Bush: Bronze , Flanges as per IS/ BS, Drilled as per IS:1538.Epoxy paint (Non-Toxic & suitable for drinking water)appliedonbody&cover insideandoutsideFasteners-CS/Galvanised steel,OutletofbigorificewillhaveascreentopreventTamperoffloat,withCI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amended up to date)PN1.0ratingsValvesincludingallmaterial,labour,testingand commissioningasperTechnicalSpecificationsandas perdirectionofEngineerin charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. 127 Class PN 1.0 128 40 mm 129 Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15as leveling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as perspecifications and standard drawings and as directed by Engineer-in-Charge. 130 For Class-A loading 131 Sluice valve chamber of size1.13m x0.85m x1.27m for pipe size-upto100mm 132 Sluice valve chamber of size1.17m x0.95m x1.415m for pipe size-from 125-to-150mm 133 Construction of RCC pillar for following size of air valves including earthwork excavation,RCC M25 grade for base slab, vertical pillar, including cost of steel reinforcement ,GI (class-B)/MS vertical pipe, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as directed by Engineer. 134 Air valve pillarfor airvalves size of 80mmdia 135 Distribution Main 136 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended up to date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. 137 HDPE PE-80PN-6 138 75 mm dia 139 90 mm dia 140 110 mm dia 141 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended up to date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply of pipe shall be in straight length in 6/12 M. 142 HDPE PE-80PN-6 143 125 mm dia 144 140 mm dia 145 160 mm dia 146 180 mm dia 147 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil 148 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 149 Manually Operated CI Sluice valve of Class PN-1.0 150 80 mm HW 151 100 mm HW 152 125 mm HW 153 150 mm HW 154 Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI single Air ValveFlanged/ Screwed type of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amendedup to date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float StainlessSteelAISI304/IS:3444,FloatGuide-HBT1,Bodyseatring-Leadedtin bronze/ SS , Seal ring and face ring - EPDM/NBR, Ends flanged according to IS 6418 orScrewed type shall have external pipe threads conforming to IS 554Fasteners - CSEpoxypaintinsideoutsideoffoodgradesafefordrinkingwater,Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. 155 Class PN 1.0 156 25 mm S-1 Type 157 40 mm S-1 Type 158 Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15as leveling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as perspecifications and standard drawings and as directed by Engineer-in-Charge. 159 For Class-AA loading 160 Sluice valve chamber of size 1.13 m x0.85 m x1.325 m-for pipe size-upto 100 mm 161 Sluice valve chamber of size 1.17m x 0.95m x1.47mfor pipe size-from 125-to-150mm 162 Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. 163 Dismantling of flexible pavement for pipe line line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work. 164 bituminous road (average thickness 300 mm) 165 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smoothwheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening & binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per MoRD Specification Clause 405. 166 Grading II (Using Screening Crushable type) 167 By Mechanical Means 168 Providingandlayinginpositioncementconcreteinspecifiedgradeover prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line andchamberwork.MeasurementforCCworktobemade asperstandard trenchwidthspecifiedintenderdocumentandnoextrapaymentshallbe madebemadefortrenchwidthmorethanspecified, completeworkasper technical specification and scope of work. 169 M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). 170 Removing& Re-fixing of Precast concrete interlocking blocks for laying of pipe linebymanualmethod,stackingofserviceable&nonserviceablematerial separately, disposal of dismantled material lead upto 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub baseasdefined.Completejobistobeexecutedasperthedirectionsof Engineer in charge. The rates to be inclusive of fixing of minimum 70 percent reusable precast concrete interlockingblock and cost of required new precast concrete interlocking block against damaged, including alllead and lift as per Technicalspecifications. (Interlockingblockmanufacturedbyfully computerizedautomaticstationeryhydraulicvibropressedmachine&full computerizedautomaticbatchingplantofclassA-1asperBS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm) 171 80 mm thick. 172 Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specificationscompleteofthefollowingsizesincludingall jointing material,costofalllabour,testingandcommissioning Technical Specifications and as per direction of Engineer. Class PN 1.0 173 80 mm dia 174 100 mm dia. 175 125 mm dia. 176 150 mm dia. 177 Survey by Electronic Total station/DGPS of villages with a view of preparing village index plan indicating roads/ streets, surface and width of road/ streets along with places of importance such as Panchayat Bhawan, Hospital, School, Post office, Temple Water Supply structures (GLRs, PSPs, pumping station physical boundary of village north etc. including levels at some important points as per instruction of engineer in charge.Hydraulic Design of Distribution network in Loop/Water Gem/EPANET or any other compatible software. Preparation of Auto CAD Drawing (A-3/A-2) with complete hydraulic design out put details, such as pipe no, node no, pipe length, pressure at node etc. Submission of three sets of colour print prepared in Auto CAD.For Length Up to 2.5 KM 178 Rate for length up to 2.5 km 179 Add extra for length more than 2.5 km 180 PUMP HOUSE AND BOUNDRY WALL 181 Construction of Pump house of required size suitable for installation of maximum 4 no. monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement. 182 Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonary in CM: 1:6 section of foundation above PCC,600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D) 4. Superstructure work: Stone masonary in CM: 1:6, W-300, height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6.6. Expansion joint shall be on every 30 mtr.7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done. 183 Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints. 184 Provision of water harvesting 185 Supply of strainer pipes made of ERWM.S.black pipe ISI Marked of following size at the site of work including required size of slotting as per IS : 8110-1985.(Item no. 4.6.2 PWD BSR ) 200 mm dia nominal bore 186 Excavation including loading, unloading, disposal and dressing of excavatedearth within initial lead of 50m and lift up to 1.5m including dressing ofexcavated area and dewatering wherever required complete in all respect. Hard / dense soil (Item no. 1(b) WRD BSR ) 187 Filter 188 Providingandlayinginpositioncementconcreteinspecifiedgradeover prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line andchamberwork.MeasurementforCCworktobemade asperstandard trenchwidthspecifiedintenderdocumentandnoextrapaymentshallbe madebemadefortrenchwidthmorethanspecified, completeworkasper technical specification and scope of work. 189 M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). (4.8 PHED 2022) 190 सेन्‍टरिंगशटरिंग (तख्ता एवम ढुलाबंदी) का आर.सी.सी. छत, स्‍लेब, छज्‍जे, लिन्‍टल आदि डालने के लिए लगाना 4.5 मीटर ऊचाई तक के लिए तथा हटाना आदि विशेष विवरण के अनुसार। शटरिंग स्टील CykWd Lrjh; nj vuqlwph 2021 iapk;r lfefr [k.Mkj ds vuqlkj dz-la- 93 c 191 Filter 192 आर.सी.सी. काम के लिए लोहे को काटना] मोड़ना तथा स्‍थान पर लगाना तथा बांधने का कार्य मय आपूर्ति के ।CykWd Lrjh; nj vuqlwph 2021 iapk;r lfefr [k.Mkj ds vuqlkj dz-la- 61 193 Supply & lowering air line of 25mm dia, G.I. pipe B class having perforation 3 to 5mm size all arrow of G.I. pipe in Zig-Zag fashion & making air vent at top including the cost of Tee-Nipples, Elbow, Socket etc.(Item no. 4.22 PWD BSR ) 194 40 मि.मी.नामीय माप की क्रेशर रोड़ी कार्य स्थल पर ( CykWd Lrjh; nj vuqlwph 2021 iapk;r lfefr [k.Mkj ds vuqlkj dz-la-- 136 C) 195 20 मि.मी.नामीय माप की क्रेशर रोड़ी कार्य स्थल पर ( CykWd Lrjh; nj vuqlwph 2021 iapk;r lfefr [k.Mkj ds vuqlkj dz-la- 136 D) 196 12/10/6 मि.मी.नामीय माप की क्रेशर रोड़ी कार्य स्थल पर ( CykWd Lrjh; nj vuqlwph 2021 iapk;r lfefr [k.Mkj ds vuqlkj dz-la- 136 E) 197 Sand GKN BSR 2019(Material Item No. 5.5) 198 Filter 199 Supply & fixing tube well cover of MS sheet (6 mm thick) with nuts & bolts complete for casing size 200 mm(Item no. 4.8.4 PWD BSR ) 200 S & F M.S. clamp, set of 50 ×6mm flat iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set(PWD BSR 2019 Item No. 4.9) 201 Provision of Household Connection 202 Providing Household Tap Connectionas per technical specification andapproved drawing and as per relevant IS code (amended up to date) from HDPE pipe line up to consumer meter/premises by using electro fusion saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance withspecification for potable water including electrofusion saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valve and specials, below ground level 20 mm nominal dia MDPE pipe PE80 PN 16 as per ISO 4427 / 20 mm nominaldia PPR-C (Three layered) pipePN16 SDR 7.4 (IS:15801:2008) (ISI mark) for and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipes with fittings in the premises for fixing a tap / meterbox (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level.Note: Road cut and restoration is not part of this item and paid seperately. 203 Average length up to 05 mtr 20 mm dia MDPE pipe/ 15 mm GI class B pipe 204 Add extra over item no 1.21 & 1.22 for providing20 mm PE80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr. 205 Road cutting for house hold service connection in minimum trench width wherever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be doneby using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge.. 206 Survey of all properties, preparation of GIS based consumer mapping of consumer water connectiondatabase, plotting assets on GIS map etc (Satellite image will be provided by the Department) 207 Data entry of existing FHTCs in rural area under JJM on website ejalshakti.gov.in; work includes visiting the village for collecting basic data consumers likei.e. Aadhar no./ration card/voter ID/BPL card/ PAN card/driving licence/passport/Antyodaya card/mobile no. etc. and entering the details on the above website. The cost also includes computer and operator.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
38.
Dairy #9863659 AOC
Tender For Various Civil Works For New 150 Mtpd Expandable To 300 Mtpd Cattle Feed Plant At Kota, Rajasthan- 1 Earth work in surface excavation not exceeding 30cm. in depth but exceeding 1.5 meter in width as well as10 Sqm on plan including disposal of excavated earth up to 50 Mtr. and lift up to 1.5 Mtr. disposed soil to be levelled and neatly dressed : All kinds of soil 2 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal ofsurplus excavated soil as directed with in a lead of 50 meter.All kinds of soils. 0M TO 1.5M 3 Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. 0 TO 1.5M 4 Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. 5 Providing and fixing up to floor five level pre cast cement concrete string or lacing courses, copings, bed plates, anchor blocks, windows sills, shelves, louvers steps, staircases, etc. including carriage, hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand) cost of required centering, shuttering and finishing smooth with 6 mm thick cement plaster 1:3 (1 cement : 3 fine sand) on exposed surface, including all T & P, curing etc. complete: 6 Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 7 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 8 Providing and laying in position Ready mix concrete manufactured in fully automatic Batching Plant and transported to site in transit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improveworkability without impairing strength and durability as per direction of Engineer in charge. All works upto floor V floor M20 grade Design Mix by using cement as per codal provision. Add extra for providing richer mixes respectively at all floor levels. Providing M-25 grade concrete by using cement as per codal provision instead of M-20 grade design mix. 9 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. 10 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. 11 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : Columns, pillars, posts and struts etc. 12 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :Walls (any thickness) including attached pilasters,buttresses plinth and string course. 13 Providing and fabricating reinforcement for R.C.C. workincluding straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.Thermo-mechanically Treated bars (Conforming of relevent IS code) 14 Brick work with F.P.S. bricks of class designation 75 insuperstructure above plinth level upto floor V level in allshapes and sizes in : Cement mortar 1 : 4 (1 cement : 4 coarse sand) 15 Half brick masonry in Superstructure , above plinth level upto floor V level using bricks of designation 75Cement mortar 1 : 3 (1 cement : 3 coarse sand) 16 Random Rubble stone masonry for with hard stone infoundation and plinth in Cement Sand mortar above 30 CM thick wall in:Cement Mortar 1:3 ( 1-Cement : 3-Sand). 17 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.Good quality South Black Above 3601 Cm2 Slabs 18 Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. FULL Edge moulding 19 P & F 1st qualityVitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete. size 600 mm X 600 mm 20 Steel work in built up tubular trusses including cutting,hoisting ( height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete. Hot finished seamless type tubes. 21 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: 22 Supplying and fixing rolling shutters of approved make, made of 80 x 1.25mm. M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including cost of spring hooks, providing and fixing necessary 25.3cm. long wire springs grade No. 2 and M.S. top cover 1.25mm thick for rolling shutters as per design & IS 6248- 1979. (Clear openable area to be measured for payment). 23 Providing & fixing ball bearing for rolling shutters 24 Extra for providing mechanical device chain and crank operation for operating rolling shutters.Exceeding 10.00 Sqm and upto 16.80 Sqm in the area. 25 Supplying and fixing of chain link fencing with angle iron posts 50x50x6mm placed at every 3 Mtr. apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with (50 x 50 x 6cm) angle iron provided and fixed and fitted with posts including earth work in excavation etc. complete with chain link size.100mm x 100mm x 3.15mm 26 Providing and fixing concertina coil fencing with required dia 610 mm (having 15 nos. round per 6 metre length) up to 3m height of wall with existing angle iron Y shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. stud tied with GI staples and GI clips to retain horizontal including necessary bolts or GI barbed wire tied to angle iron all complete as per direction of Engineer In Charge with reinforced barbed tape (R.B.T.)/Spring core(2.5 mm thick) wire of high tensile strength of 165 kg/sq.mm with tape (0.52 mm thick) and weight 43.478 gm/metre (Cost of MS angle, CC block shall be paid extra) 27 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpetwashers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required. 0.80 mm thick with zinc coating not less than 275 gm/m2 28 Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand).For Area of each slab from 2001 to 5000 sq. cm. 29 Random rubble dry stone Kharanja under floor. 30 Plaster on new surface on wall in cement sand mortar 1:3 including racking of joints etc. complete fine finish :12mm thick 31 Plaster on new surface on wall in cement sand mortar 1:3 including racking of joints etc. complete fine finish : 20 mm thick 32 6 mm thick cement plaster to ceiling of mix 1:3 (1cement : 3- fine sand) 33 Wall painting with plastic emulsion paint of approved bran and manufacture to give an even shade including allscaffolding: Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. 34 Finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specifications including primer coat and protecting coat including scaffolding and safety provision Trowel Finish av. thickness 1500 to 2000 microns. 35 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying :(i) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.(ii) laying second layer of Fiber glass cloth when the first layer is still green . Overlaps of joints of fiber cloth should not be less than 10 cm.(iii) Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proffing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around(iv) fourth and final layer of brick tiling „with cement mortar or any other approved protective coarse. (which will be paid for separately) For the purpose of measurement the entire treated surface will be measured 36 Providing and fixing of uPVC Sliding windows: Frame Made from the Extruded uPVC Window Profile Section of size 106w x 50h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and 3 box multi-chamber construction, Laminated (colour) finish, duly reinforced with 1.2 mm thick GI section. Frame shall have three track configuration, Vertical member of frame which bears the sliding shutter load shall have aluminium rail/track for smooth sliding of shutter rollers. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side.Shutter : The shutter of sliding window shall be made of 39w x 69h mm Extruded 3 box multi- chamber uPVC Window Profile Section of laminated (colour) having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5mm thick GI section duly mitered cut & thermal welded at all corners and fitted with uPVC glazing bead of size 22 x 20 mm with inner and outer co-extruded EPDM/TPE-E weather seal gaskets alongwith 6mm thick ISI make plain float glass 37 Providing and fixing of openable uPVC Doors with or without fix top: Frame Made of Extruded uPVC Window Profile Section of size 60w x 70h mm having outer wall thickness of 2.75mm (+/- 0.2mm) and 3 box multi-chamber construction, Laminated (colour) finish, duly reinforced with 1.2mm thick GI section. All the corners shall be mitered cut & thermal welded so as to form door frame. Fix Mullion made of 60w x 80h mm uPVC Profile Section with steel reinforcement shall be provided for the top fix portion of the doors or in case of the doors having more than two openable shutters, as per the requirement / drawing. Frame of openable door shall have coextruded EPDM/TPE-E gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Shutter : The shutters of openable door shall be made of 60w x 95h mm Extruded 3 box multi-chamber uPVC Window Profile Section of laminated( colour) having outer wall thickness of 2.75mm (+/- 0.2mm) provided with reinforcement of 2.0 mm thick GI section duly mitered cut & thermal welded at all corners, provided with center mullion (if specified in drawing) of size 60w x 80h mm uPVC Profile Section and fitted with uPVC glazing bead of size 36 x 20mm with inner and outer co-extruded EPDM/TPE-E weather seal gaskets alongwith 6mm thick ISI make plain float glass. All welding joints of frame and shutter shall be cleaned and milled with the CNC mechanism to provide uniform grooved finish on all visible joints. Hardware: Each openable door shutters is to be fixed with three load beading butt hinges and locking of doors is to be provided with multi-point transmission gear (ESPAG) with white finish powder- coated lockable handle. Installation at site: 38 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 39 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work 40 Finishing with neat cement (punning). 41 Add extra for foundation/trenches/drains for every additional lift of 1.5 Mtr. or part thereof inAll kinds of soil 42 Supplying and applying bituminous solution primer on roofs or on wall surface at 0.24 litre per sqm. 43 Random Rubble stone masonry with hard stone insuperstructure above plinth level and upto five level above 30cm. thick walls in :Cement Mortar 1:3 ( 1-Cement : 3-Sand). 44 Pointing on stone masonry in cement sand mortar 1:3 (1cement : 3 sand) :Raised and cut pointing. 45 Construction of Tube-well from ground levels and up to 100 mtr. depth to accommodate housing and assembly pipes of following sizes in all types of alluvium strata by rotary drilling method and with gravel as per IS 4097-1967and packing as per IS2800 Part-I & II 1979 as amended upto date(the work includes the cost of gravels& its primjaryand packing during development,lowering of housing & strainer assembly pipes,with suppy and warping of coir-rope, wherever necessary, for arresting fine sand particles. The Work will not include cost of housing pipe and strainer pipe assembly and development work would be complete after obtaining sand free water).200mm-do- 46 Construction of tube-well upto any depth in all type of rocks by DTH system and over burden, to accommodate casing pipe of the 200 mm in all types of soils and overburden including lowering of casing pipes, but excluding cost of casing pipes as per IS:2800 (Part I & II) 1979 specifications.The work would be completed after development of tube-well obtaining sand free water.Tubewell should have a throught bore as per nominal dia of casing pipe. 200mm-do- 47 Supplying of ERW M.S. black casing pipe ISI marked (IS:4270/1992) of grade FE 410of sizes at site of work.200 mm nomonal bore of pipe. 48 Supply/Fixing of tubewell cover of M.S. Sheet 6mm thick with nut & bolt complete for 200mm dia M.S. black Casing pipe. 200mm dIa 49 Supply / fixing strainer pipes made of ERW M.S. black pipe ISImark of following size at the site of work including required size of slotting as per IS:8110-1985.200mm-do- 50 Providing & lowering G.I. flange pipes including rubber washer and nuts of 8mm dia complete in all respect 50mm dia B class ISI mark, Jindal / T.T.Swastik. 51 Providing and fixing G.I. B -Class pipe Jindal/ T.T. Swastik Make(external work) with G.I. fittings (IS:1239 Make) including trenching and refilling earth. (A) 50 mm nominal bore. 52 Providing and fixing gun metal non-returned valve or check valve ISILeader Make superior quality. 50mm dia horizontal type. 53 Supply & fixing M.S. Clamp Set of 50 x 6mm flat iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump set. 54 Development of Tube well as per IS specification using suitable compressor to give sand free water for required yield of the graval packed tube well. 55 Suppy of 50 mm dia G.I. medium class pipe (each length 5.8 m to E 6.0 m) tripod as per drawing and design with chain pulley of 3MT capacity. 56 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure A :30 mm thick.Commercial Veneer both side 57 Providing and fixing pressed steel door frames confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4(M15 grade) complete as directed by Engineer-incharge :Profile E 58 CARRIAGE OF MATERIALS Earth, Sand, Lime, Morrum manure or sludge.UPTO 5 KMS 59 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5 m , disposed earth to be levelled and neatly dressed : All kinds of soil 60 Providing and fixing Stone jali 40mm thick Red/Pink sand stone throughout in cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali patterns to be cut square to jali slab without any chamfers etc: 61 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20% 62 Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion) . 63 Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : Serrated with central bulb (225 mm wide, 8-11 mm wide)
Contract Date: Mar 23, 2026 Contract Value : 27.84 Crore
Cooperative No of Bidders 3
40.
Defence #9835139 AOC
Tender For Completion Of Incomplete Work For Provn Of Otm Accommodation (Ph-I Of Two Phs) At Panagarh Mil Stn Under Ge (P) Panagarh.; 1 Sch A Part -I (Building Works)Note:- This Sch is notpre-priced by MES and the pre-priced rate indicatedas Rs 0.00 under Col 5 signifies this fact only. 2 Completion of incomplete Building for signal unit with all fitting and fixtures etc. Complete all as specified and as shown on complete drawings. 3 Completion of incompleteBuilding for office accn/ Adm block with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 4 Completion of incomplete Building for JCO Mess and single living JCO accn with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 5 Completion of incomplete Buildingfor single living ORs accn / Dinning and cook house with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 6 Completion of incomplete Building for Storage Accn (Armouries)& Guard House alongwith hardstanding with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 7 Completion of incomplete Building for Store Room (General Authorisation) with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 8 Completion of incomplete ramp with all fitting and fixtures etc. Complete all as specified and as shown on drawings 9 Completion of incomplete Building for sentry post with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 10 Completion of incomplete Building for Ironing Room with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 11 Completion of incomplete Building for Meter & Switch House with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 12 Completion of incomplete Pump House/ UG water tank with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 13 Completion of incomplete RCC OHT Tankwith 18mtr staging with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 14 Completion of incomplete Incinerator with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 15 Completion of incompleteFlag mast with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 16 Completion of incomplete Alarm post with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 17 Completion of incompleteFire point with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 18 Completion of incomplete Refuse bin with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 19 Completion of incompleteDhobi ghat with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 20 Lumpsum price worked out by the tenderer/ bidder for SITE CLEARENCE, AREA DEVELOPMENT, EARTH WORK AND EXCAVATIONas listed in Schedule ‘A’ Part-II on Serial Page No. __ 21 Lumpsum price worked out by the tenderer/ bidder for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-III on Serial Page No. __ 22 Lumpsum price worked out by the tenderer/ bidder for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IV on Serial Page No. __ 23 Lumpsum price worked out by the tenderer/ bidder for ROAD/ PATH/ CULVERT as listed in Schedule ‘A’ Part-V on Serial Page No. __ 24 Lumpsum price worked out by the tenderer/ bidder for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI on Serial Page No. __ 25 Lumpsum price worked out by the tenderer/ bidder for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VII on Serial Page No. ___ 26 Lumpsum price worked out by the tenderer/ bidder for SECURITY FENCING AND GATE as listed in Schedule ‘A’ Part-VIII on Serial Page No. ___ 27 Lumpsum price worked out by the tenderer/ bidder for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IX on Serial Page No. ___ 28 Lumpsum price worked out by the tenderer/ bidder for EXTERNAL ELECTRIC SUPPLYas listed in Schedule ‘A’ Part-X on Serial Page No. ___ 29 Lumpsum price worked out by the tenderer/ bidder for LIGHTENING PROTECTIONas listed in Schedule ‘A’ Part-XI on Serial Page No. ___ 30 Lumpsum price worked out by the tenderer/ bidder for RAIN WATER HARVESTING / RECHARGE PIT as listed in Schedule ‘A’ Part-XII on Serial Page No. ___ 31 Schedule ‘A’ Part-XIII (MISCELLANEOUS ITEMS)Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under Col. 5 signifies this fact only. 32 M & L for mixing of Fly ash, Clinker & stone dust in proportion of 1:3:6 ( i .e10 %Fly ash, 30% Clinker and 60% Stone dust) laying , watering , ramming and compacting with vibratory roller to get min CBR value 8% and Dry density 97 % placed at required camber and gradient complete as directed .Note:Break down details of this Items is shown in Annexure ‘B’ in Schedule ‘A’ Notes. 33 (INTERNALELECTRIFICATION)Material and labour for point wiring with 1.5sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed PVC rigid conduitheavy grade of adequet size dia with all fittings and accessories for modules switch/socket etc in metal flush box screws complete including PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 1.5sqmm green colour as earth continuty conductor connected to common earth dolly for one light/ fan point / call bell point controlled by one, one way switch complete all as specified and as directed. 34 All as per Ser Item No 13.02 here-in-above but for one ceiling/ exhaust fan point controlled by one switch complete all as specified and directed. 35 Material and labour for point wiring with 1.5sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed PVC rigid conduitheavy grade of adequet size with all fittings and accessories for modules switch/socket etc in metal flush box modular with cadmium plated iron screws completeincluding PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 1.5sqmm green colour as earth continuty conductor connected to common earth dolly for one 5/6 Amps socket outlet points controlled by one, one way switch on independent board complete all as specified and as directed. 36 All as per item No. 13.04 above but one 5/6amps socket outlet point on the same board with other switches complete all as specified and as directed. 37 All as per item No. 13.02 above but for one Point wiring controlled by two nos two switch complete all as specified and as directed. 38 Material and labour for point wiring with 4sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed PVC rigid conduitheavy grade of adequet size with all fittings and accessories for modules switch/socket etc in metal flush box modular with cadmium plated iron screws completeincluding PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 4 sqmm green colour as earth continuty conductor connected to common earth dolly for one15/16 Amps socket outlet points controlled by one, one way switch modular type on independent board complete all as specified and as directed. 39 Material and labour for point wiring with 1.5sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed stove enameled steel conduit of adequet size dia with all fittings and accessories for modules switch/socket etc in metal flush box modular with cadmium plated iron screws completeincluding PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 1.5sqmm green colour as earth continuty conductor connected to common earth dolly for one light/ fan point controlled by one, one way flame proof rotary type switch complete all as specified and as directed. 40 Supply and fixing switch flame proof rotary type with terminal box in LM6, 16 amps single pole 230 volts complete all as specified and as directed. 41 M & L for modular metal flush box 12 Module complete all as specified and directed. 42 M & L for modular white cover plate with frame, 12 module complete all as specifed and directed. 43 S & F for LED lamp 7 watt (retrofit) complete all as specifed and directed. 44 S & F LED type conical shape wall metal body with 1 no 7 Watt retrofit LED Lamp minimum lumen 700, complete all as specifed and directed. 45 S & F LED type table lamp / bed side light ( 3000k) Metal body 2 Watt minimum 50 lumen complete all as specifed and directed. 46 S & F telephone Socket (RJ-11) modular type complete all as specifed and directed. 47 S & F TV Socket modular type complete all as specifed and directed. 48 Supplying and fixing ceiling fan five star rated withBrush Less direct current (BLDC) 1200 mm sweep (without remote ) , 28 W complete withblades,down rod and accessories,230v,Min delivery 210 CFM with service value 6.00 BEE complete all as specified and as directed. 49 All as per Ser Item No 13.17 here-in-above but for 1400mm sweep, Minium air delivery 245 CFM with service value 6.00 BEE, five star rating with brushless direct current motor (BLDC) complete all as specified and directed. 50 Supplying and fixing exhaust fan made of sturdy Engineering plastic complete with lovers shutters, AC single phase, 230 V, 50 HZ , 1200 RPM, Copper winding, 250mm Sweep complete all as specified and directed. 51 Supplying and fixing exhaust fan noiseless square type metal body case , 450mm sweep heavy duty single phase (1400 RPM) ISI marked with blades flush mounting withlouvers, AC single phase 230/240 volts, 50 Hz including necessary fixing accessories and make good of surfaces complete all as specified and as directed. 52 Supplying and fixing sheet metal enclouser for Vertical DBS Triple pole and neutral 6 way double door 415 Volts when MCCB 4 Pole to be used as incommer complete all as specified and as directed. 53 Supplying and fixing sheet metal enclouser for Vertical DBS Triple pole and neutral 8 way double door 415 Volts when MCCB 4 Pole to be used as incommer complete all as specified and as directed. 54 Supplying and fixing sheet metal enclouser for Vertical DBS Triple pole and neutral 4 way double door 415 Volts when MCCB 4 Pole to be used as incommer complete all as specified and as directed. 55 Supplying and fixing MCCB 125 Amps, capacity 25kA, 4 pole, 415 volts (Adjustable thermal type & fixed magnetic setting) complete all as specified and as directed. 56 Supplying and fixing sheet metal enclouser for DBS Single pole and neutral 6 way double door with 200 Amps rated bus bar 240 Volt complete all as specified and as directed. 57 Material and labour for sub main wiring with two runs of single core 4 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded,unsheathed1100 volts grade in PVC concealed rigid conduit (heavy grade) of not less than 20 mm diawith all fittings and conduit accessories concealed type including one run 4 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694)as earth wire complete all as specified and as directed. {Note:-(i) Two runs of cable with one run earth wire and PVC conduit shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.} 58 Material and labour for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded,unsheathed1100 volts grade in PVC concealed rigid conduit (heavy grade) of not less than 20 mm dia with all fittings and conduit accessories concealed type including one runs 6 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694)as earth wire complete all as specified and as directed. {Note :-(i) two runs of cable with one run earth wire and PVC conduit shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.} 59 Material and labour for sub main wiring with four runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded,unsheathed1100 volts grade in PVC concealed rigid conduit (heavy grade) of not less tha 25 mm dia with all fittings and conduit accessories concealed type including two runs 6 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694)as earth wire complete all as specified and as directed. {Note :-(i) Four runs of cable with two runs earth wire and PVC conduit shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.} 60 Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cm x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level,connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI or steel wire 4 mm dia as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation andearth work insoft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregatepit, funnel,20mm dia GI medium grade watering pipe, 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @100mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternate layer of 15cm thick including complete all as specified and directed. {NOTE:- (i) Each protection pipe and earth lead upto and including 7.50m length is deemed to be included in unit rate of of this item..} 61 (ROAD/PATH)M & L 225 mm thick (compacted thickness)wet mix macadam( WMM), with curshed stone aggregate and stone dust (as per design mix)of specifiedgrading, spread using mechanical paver as specified, watered, rolled & consolidated as specified to required gradient and camber complate all as specified & directed. 62 M&L for laying polythene paper black 150 micron with laps complate all as specified & directed. (Area for polythene paper without considering lap shall be measured and paid) 63 M&L and laying 150 mm thick (compacted thickness) wet mix macadam (WMM) with crushed stone aggragate of specified grading,spread using mechanical paver as specified, watered, rolled and consolidated as per required greadeant and camber complate all as specified & directed. 64 M&L for 100 m thick dry lean concrete (DLC) over a prepared subgrade with coarse and fine aggregate conforming to IS : 383, Size of aggregate not exc 40 mm (Grading and other parameters as per table 600 - 1 of MORTH, IRC SPR : 49 Specification) complate all as specified & directed. 65 M&L for cleaning and preparing the road surface and making good for road marking applying reflective thermoplastic white road marking paint (HOT APPLICATION) comforming to BIS 3262 laid down through modern propelled road marking machine in a layer of CRYSTALEX and use of all ingredients such as binder, glass, beads, titanium dioxide, calcium carbonate, interfiller thermoplastic required for glass beads per square meter by incorporating the white glass beads for reflectivity in 100mm width complete all as specified and as directed.Make of Thermoplastic Road marking paint/Retro-Reflective paint - M/s Asian Apcomark, M/s STP or M/s Shalimar Paints Ltd or M/s Berger Paints Ltd, M/s Jhonson & Nicholson Paints Ltd or M/s Jotun India Pvt Ltd. 66 (SEWAGE DISPOSAL)M&Lfor constrution of RCC Septic tankcoventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 150 users Complete all as shown on drawing and as directed. 67 M&L for constrution Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.4 M dia X 4.5 M effective depth Complete all as shown on drawing and as directed. 68 (EXTERNAL WATER SUPPLY) Design, supply, install, testing and commissioning Iron removal pressure feed type filtration plant 10000 GPH to with stand pressure 10 Kg/Sq cm with catalytic and filter media (as required size and grade / mesh to obtain potable water recommended parameters as per WHO) including MS frontal pipe (duly welded), Cocks, valves, (inlet outlet, back wash, rinse, bypass complete as per manufacturers instruction). Provision of main hole Hand hole strainer including air vent system, coagulant feeder with accessories, oxidation chamber with media, (MnO2) with all accessories suitable capacity with all fitting fixture, pressure gauges, RCC/PCC foundation as per OEM recommendation. Drainage system and connected to rising and delivery system including painting and writing complete. The technical details of Oxidation chamber and Multigrade filter are as given below:- 69 A) Oxidation Chamber- (i)Feed Flow - 40 M³/Hr. (ii) Operating pressure - 3.5 kg/cm². (iii) Max. allowable pressure drop - 0.5 Kg/cm. (iv) MOC of vessel - MS. (v) Frontal Pipeline Size - 150/100mm. (vi) Media type - Manganese-di-oxide. (vii) Thickness in mm (shell and dish-ends) - 6 mm. (viii)Media Quantity - 600 Kg. (B) Multigrade Filter- (i) Flow rate - 40 M³/Hr. (ii) Operating pressure - 3.5-5.5 kg/cm². (iii) Max. allowable pressure drop - 0.5 Kg/cm². (iv) Continuous duty cycle - 48 Hrs. (v) Backwash - 20 Min. (vi) Rinsing - 10 Min. (C) Filtering Media Details- (i) Media Type - Mixed sand. (ii)Depth of sand - 2800 Kg. (iii) Depth of Gravels support - 2000 Kg. (iv) Guaranteed life of filtering media - One year.(D) Vessels Details- (i) Type Cylindrical - Vertical. (ii)Dimension in mm (DIA X HOS) - 1600 X 2300 mm. (iii) Free board for back wash - 50%. (iv)Materials - MS. (v) Thickness in mm (shell and dish-ends) - 8-10mm. {Note:-- Rate deemed to be included with the followings:-(a)Raw water and treated water tested report of all parameter from National Test House Salt Lake. (b)Training to DEL Staff with required material and maintaining log book and other register as directed. (c) Electronic flow meter-01 including necessary wiring complete. (d)Butter fly and gate valves as required.(e) 2 Nos air compressor of capacity 210 CFM with 3 Phase Motor, Starter, air pipe connection including electrical connection complete. 70 Supply, install, lowering, testing & commissioning of submersible pump set 8 stage, suitable forminimum head 40 Mtr with 635 lpm dischage with electric driven motor of capacity 15 hp, 415 V AC, TP with operational efficeiency performance and durability wide voltage range 350-440 Volts, super finished water lubricated bush bearing, with less speed drop motors with reflon bearing and sand guard complete all as specified and directed by Engr-in-charge. 71 Trail drilling of bore of size 250 mm dia upto 120 mtr depthby direct rotary/ DTHmechanical system for injection wellin any kind of soil strata including hard stone/boulders and submitting the strata detail both graphically recorded as well as strata results including testing of yield , complete all as specified and as directed. 72 Reaming of bore well from 250 mm dia to 525 mm dia hole in three steps from 250 mm to 350 mm, 350 mm to 450 mm and 450 mm to 525 mm dia bore siutable for lowering ERW Mild steel casing pipes and gravel packing for the required length (i.e 50 mtr depth) below the ground level , complete all as specified and as directed. 73 All as per item no 13.41 here-in-before but exceeding 50 mtr and upto 170 mtr depth, complete all as specified and as directed. 74 Supply, assembling, lowering and fixing in position 250 mm nominal (10) bore ERW MS housing pipe, ISI marked,of 8 mm wall thickness, screwed and socketed in random length upto 6 mtr including fitting of centralizer at regular interval into bore hole to a depth upto 40 mtr from ground level, as per IS 3589, painted both inside and outside with black bituminous paint suitable for drinking water purpose including necessary fittings & fixtures by jointing electric Arc welding , complete all as specified and as directed. 75 Supply, assembling, lowering and fixing in position 200 mm nominal (8) bore ERW MS housing pipe, ISI marked,of minimum 8.0 mm wall thickness, screwed and socketed in random length upto 6 mtr including fitting of centralizer at regular interval into bore hole to a depth exceeding 40 mtr and upto 120 mtr from ground level, as per IS 3589, painted both inside and outside with black bituminous paint suitable for drinking water purpose including necessary fittings & fixtures by jointing electric Arc welding, complete all as specified and as directed. 76 Supply, assembling, lowering and fixing in position low carbon galvanized (LCG) steel strainer pipe 200 mm nominalbore of wall thickness 7.00 mm cagetype wire wound screen ‘V’ shaped profile in suitable length having slots of size 1.6 mm width including necessary end coupling,electric Arc welding as required and including special sockets for connecting to MS pipe, complete all as specified and as directed. 77 Supply and fixing mild steel reducer suitable for (250 x 200 mm ) bore casing pipe, 10 mm thick, fitted to casing pipe as per IS 2800 by means ofelectric Arc welding ,complete all as specified and as directed. 78 M&L for carrying out electro logging test upto complete drilling depth of tube well for fixing water strata and submitting of Report including its interpretation by a qualified Hydrologist/ground water expert , complete all as specified and as directed. 79 S&Fmild steel bail plug assembly suitable for 200 mm bore casing pipe internal threaded with strong iron hook, screwed and welded to casing pipe as per IS 2800 , complete all as specified and as directed. 80 Supply, filling and packing washed pea gravels of size 2 mm to 4.6 mm all around casing pipe and slotted pipe, complete all as specified andas directed 81 S&F mild steel housing clamps 1200 mm long 100 mm wide , made out of 20 mm thick MS plate made to shape for 250 mm bore casing pipe with necessary bolts, nuts and washers at ground level, complete all as specified and as directed. 82 Developing of tube well by means of air compressor, for number of hours, until sand free clear potable water is obtained including testing by using diesel engine driven turbine pump to get maximum yield and discharge including supply of yield test result , complete all as specified and as directed. (Note : The rates of DHPP is inclusive in the quoted rate) 83 S & F well cap made out of 5 mm thick MS Plate with provn of suitable holes for passing two runs of flat 3 core PVC insulated sumersible cable motor and one run of SWR, 100 MM dia column pipe and suitable for fixing 250 mm nominal bore ERW heavy duty MS of 8.0 Mm Wall thickness casing pipe complete all as specified andas directed. 84 S&F pressuregauge with isolation cock suitable for a working pressure of 7 Kg/cm² (Liquid based High Intensity), complete all as specified and as directed. 85 Supply and laying flat PVC insulated PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade 10 Sqmm 3 core including jointing material and connection work , complete all as specified and as directed. 86 S&F round strand steel wire rope dia 12 mm and connected clamp nut bolts fixed ,complete all as per directed. 87 Supply , lowering and fixing MS column pipe 100 mm bore, medium grade, confirming to IS, 3 meter long pipe both end flanged, threading, welding and drilling of holes, cutting of ducts of size 10 mm x 20 mm 2 No. in each flange for fixing submersible cable, including rubber gasket of suitable size, nuts, bolts, washer etc including painted internally and externally with two coat of non corrosive non toxic bituminous paint including making all type of connections as required, complete all as specified and as directed. 88 Supply , install, testing and commissioning of cubical housing cabinet type weather proof powder coated LT panel board indoor type, platform mounted factory made, totally enclosed dust and vermin proofof CPRI approved,openablefrom both front and rear side made of2 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowing:- 89 (i) Aluminium Bus bar 160 Amps -25 KA breaking capacity(ii) Incoming MCCB, 4 pole, 100 Amps, 415 Volt AC, 25 KA rupturing capacityQty 1 No(iii) Outgoing MCCB, 3 pole, 32 Amps, 415 Volt AC, 10KA rupturing capacityQty 4 Nos(03 For submersible pump and 01 standby)(iv) Outgoing MCB 4 Pole 32 Amps, 10 KA, 240 Volts - 01 Nos(v) Star delta motor starter suitable for 15 HP motor pump - 03 Nos(vi) LED indicating lamps - 03 Nos(vii) Digital Volt meter (Size - 96 x 96mm) 0-500 Volts with selector switch - 01 No(viii) Digital Ammeter (Size96x96mm) With selector switch including CT ( 100/5Amp) with all connection- 01 No(xiv) Matering and accessories complete all as directed by Engr-in-Charge. 90 Supply, installation, commissioning and testing of 200mmsluice valveof cast iron body flangedconforming to IS-14816, PN-1.6 Non rising type spindle and hand wheel including all jointing materials such as nuts, bolts, washers, & fibre/ rubber gasket as required complete all as specified and as directed. 91 Supply, installation, commissioning and testing of 150mmsluice valveof cast iron body flanged conforming to IS-14816, PN-1.6 Non rising typespindle and hand wheel including all jointing materials such as nuts, bolts, washers, & fibre/ rubber gasket as required complete all as specified and as directed. 92 Material and labour for Construction of brick masonry valve pit of internal dimension 90 cm x 90 cm x 90 cm depth with fly ash brick in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping including formwork MS frame with 50 x 50 x 6 mm angle iron 5 mmthick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and directed. 93 Material and labour for Construction of brick masonry valve pit of internal dimension 60 cm x 60 cm x 60 cm depth with fly ash brick in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping including formwork MS frame with 50 x 50 x 6 mm angle iron 5 mmthick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and directed. 94 Supply, install, testing & commissioning of Centrifugal pump suitable for minimum, Discharge 635 LPM at 30 Mtr head with cast iron casing, bronze impeller, SS Shaft, electric driven motor of 10 HP, 415 V, TP suitable for under ground sump and install complete including PCC foundation as per manufacture instruction complete all as specified and directed. 95 Supply, install, connecting, testing & commissioning of high pressure single head adjustable chemical dozing system of the folowing specification : (a) Adjustable high pressure 100 PSIG Power input 230 V, 50 HZ, Max flow rate 02 US GPD to 40 US GPD with mandatory assecceries like lead tubing connecting ferrules, check valves, 170 ltr FRP solutin preparetion tank with lid, port hole, inlet/outlet/drain connection, level guage ete and fitted with 900 RPM motor PVC agitator combined with 100 ltr dosing tank lid port hole inlet/outlet/drain connection, level guage etc either fitted with 900 RPM moter and PVC agitator complete all as speficified and directed.Make : Any make of E-in-C approved or ISI Marked of any make as approved by Accepting Officer. 96 Supply and laying DI Pipe 200mm dia of class K-7 Spigot and socket type with and including titan joint gasket complete in any length laid in trenches complete all as specified and directored. 97 Supply and laying DI Pipe 150mm dia of class K-7 Spigot and socket type with and including titan joint gasket complete in any length laid in trenches complete all as specified and directored. 98 M&L DI Fittings bends (any type radius and angle) tapers any type, (straigth, bend, increasing, decreasing or double socket etc) Tee pieces single branch Y junctions double branch, cross (all sockets or socket and spigout ) collars, caps and plugs upto 300 mm bore complete all as specified and directored. 99 (EXTERNAL ELECTRIC SUPPLY)suply , installation and commissioning of compact secondary substation (CSS) 315KVA comprising to following parameters:-(a) Housing to made with conforming to the norms of CPRI, CRCA sheet steel housing 3.15mm thick with corrosion resistance and all side openable hinged door and lock and key arrangements.(b)Steel parts are tested as per IS 6988.(c)Engineered for smooth air flow for natural cooling.(d)No acces to high voltage parts.(e) GI strip earthing for lightening protection and lightening spike etc.(f)Separate earthing for lighrening protection and lightening spike etc.(g)Separation steel sheet wall for VCB/ Transformer/ LT Panel.(h) Heavy lifting lugs with all equipment load.(j) Slopped roof.(k) Necessary danger plates outside fo the CSS.(l) Necessary HT and LT cable / earth strips opening.(m)Necessary form work incl foundation as per OEM recommendation. 100 (n) Circuit Breaker (CB) in SF6 insulated stainless steel enclosure. commissioning of with metering module with necessary CTs adn PT, comprising the following :- (Complete unit is to be installed inside CSS, protection accessories, Enclosoure: Metal Clad, IP-54 Protection Relay : Self Powered Alfa neumatic LCD display type internal are tested for 1 sec, fully compartmentalized sheet enclosure with automatic sagety shutters, GI foundation bolts with provision of cable terminating facilities with powder coated smooth glossy finish and as per follows:(i) Rated Voltage - 12 KV(ii)Rated Frequency - 50 Hz.(iii)Rated continuous current rating - 630 Amps(iv)Impulse withstand voltage - 75 KV(v) Bus bar rating- 150% of continuous current.(vi)Operation: Spring closing mechanism- DC motor operated with 24 volt supply, Breaker Closing- manual & Electrical through TNC switch. 101 (vii)Shunt trip coil- 230 V, AC(viii) Safety interlock locking facility - Required(ix)Breaker panel indication - ON (RED)/ OFF (Green)(x) Accessories: Mechanical counter, space heater with thermostat, fuse adn ON/OFF switch, Aux relays for remote trip/ indication for PC interface etc, cubicle illumination lamp LED 9 watt retrofit type 230 V AC, T-N switch, anti pumping contractor etc.(xi) Mimic Diagram : An operating mimic diagram shall be provide on the front side of each cubicle(xii)Battery Bank with charger for SF 6 Circuit Breaker is included in the item rate and rating of battery as described by OEM.(Note : SF 6 Circuit Breaker complete will be obtained directly from the OEM and not from the authorised system assemblers of OEM.The installations, calibration and testing of CB will be conducted in the presence of authorised representative of OEM by the Contractor.) (o)Transformer 315 KVA Copper wounded dry resin cast distribution type 11/0.433 KV, 3 phase, 4 wire LT output 50 Hz DYN 11 suitable for indoor installation of load tape changer with step + 7.5% upto (-) 7.5% in step of 25.% on HT side all technical specification comprising to IS 11171 update version part with all necessary satndard fittings and accessories complete after necessary testing after completion with the following specification : (i) Standard KVA Rating- 315 KVA (ii)Primary Voltage - 11 KV AC(iii) Secondary Voltage - 433 Volts . 102 (iv)Neutral earthing should be solidly earth system (v) Rated Frequency - 50 Hz with + (-) 3% Tolerance (Note : All outgoing MCCBs should be adjustable thermal and magnetic protection and Ics = 100% Icu for all MCCBs). q) Necessary interconnections for HT and LT equipment with suitable size insulated copper bus bar.(r) Necessary foundation for installations of CSS. 103 Suply , installation and commissioning of Compact Secondary Substation (CSS) 250 KVA comprising to following parameters :-(a) Housing to bemade with Conforming to the norms of CPRI, CRCA sheet steel housing 3.15mm thick with corrosion resistance and all side openable hinged door and lock and key arrangements.(b)Steel parts are tested as per IS 6988.(c)Engineered for smooth air flow for natural cooling.(d)No acces to High voltage parts.(e) GI strip earthing for lightening protection and lightening spike etc.(f)Separate earthing for lightening protection and lightening spike etc.(g)Separation steel sheet wall for VCB/ Transformer/ LT Panel.(h)Heavy lifting lugs with all equipment load.(j) Slopped roof.(k) Necessary danger plates outside of the CSS.(l) Necessary HT and LT cable / Earth strips opening.(m)Necessary form work incl foundation as per OEM recommendation. 104 (n) Circuit Breaker (CB) in SF6 insulated stainless steel enclosure. commissioning of with metering module with necessary CTs and PT, comprising the following :- (Complete unit is to be installed inside CSS, protection accessories, Enclosoure: Metal Clad, IP-54 Protection Relay : Self Powered Alfa neumatic LCD display type internal are tested for 1 sec, fully compartmentalized sheet steel enclosure with automatic safety shutters, GI foundation bolts with provision of cable terminating facilities with powder coated smooth glossy finish and as per follows:(i) Rated Voltage - 12 KV(ii)Rated Frequency - 50 Hz.(iii)Rated continuous current rating - 630 Amps(iv)Impulse withstand voltage - 75 KV(v) Bus bar rating- 150% of continuous current.(vi)Operation: Spring closing mechanism- DC motor operated with 24 volt supply, Breaker Closing- manual & Electrical through TNC switch.(vii)Shunt trip coil- 230 V, AC(viii) Safety Interlock Locking facility - Required(ix)Breaker panel indication - ON (RED)/ OFF (Green)(x) Accessories: Mechanical counter, Space heater with Thermostat, Fuse and ON/OFF switch, Aux relays for remote trip/ indication for PC interface etc, cubicle illumination lamp LED 9 watt retrofit type 230 V AC, T-N switch, anti pumping contractor etc.(xi) Mimic Diagram : An operating mimic diagram shall be provide on the front side of each cubicle. 105 (xii)Battery Bank with charger for SF 6 Circuit Breaker is included in the item rate and rating of battery as described by OEM.(Note : SF 6 Circuit Breaker complete will be obtained directly from the OEM and not from the authorised system assemblers of OEM.The installations, calibration and testing of CB will be conducted in the presence of authorised representative of OEM by the Contractor.) (o)Transformer 250 KVA Copper wounded dry resin cast distribution type 11/0.433 KV, 3 phase, 4 wire LT output 50 Hz DYN 11 suitable for indoor installation of load tape changer with step + 7.5% upto (-) 7.5% in step of 2.5% on HT side all technical specification comprising to IS 11171 update version part with all necessary standard fittings and accessories complete after necessary testing after completion with the following specification : (i) Standard KVA Rating- 250 KVA (ii)Primary Voltage - 11 KV AC 106 (iii) Secondary Voltage - 433 Volts (iv)Neutral earthing should be solidly earth system. (v) Rated Frequency - 50 Hz with + (-) 3% Tolerance.(p)LT Panel for 250 KVA Transformer made with 2 mm CRCA sheet with necessary angle iron frame and vermin proof font side openable double door with necessary locing arrangement opening for bus bar / cable entry opening for natural air ventilation / cooling necesary Ammeter, Voltmeter, Selector switch, CTs , suitable size bus bar, paints and primer with Air Circuit Breaker (ACB) as incomer 630A, 50 KA, 415 V , AC, 50 Hz, 4 Pole with neccesary setting and microprocessor control draw out type bus bars, as outgoing MCCB 200 Amps, 35 KA - 02 Nos, MCCB 160 Amps, 35 KA - 02 Nos & 32 A MCB 4 Pole - 04 Nos. (Note : All outgoing MCCBs should be adjustable thermal and magnetic protection and Ics = 100% Icu for all MCCBs).(q) Necessary interconnections for HT and LT equipment with suitable size insulated copper bus bar.(r) Necessary foundation for installations of CSS. 107 Supply and fixing LED street light fittings on ploes capacity 45 Watts, high pressure die cast aluminum housing IP 66 rating front cover made of toughened clear glass, suitable for pole mounting wih bracket arm 40mm dia, Gl light grade pipe upto 1.4 m long, bend to required shape, clamp 40mmx6mm or required length including nuts & bolts fixed on steel poles complete all as specified.Model No : ENDURASUNDOWNSL45WLED765PASYBOTG of make : Havells or equivalent make as per Appendix D. 108 Supply & Fixing junction box with 3 Phase terminals and size of box 130mm x 180mm x 77mm or nearest higher size made of polycarbonate with IP 66/67 degree of protection, dust proof, water tight,shock proof, fire retardant,with internally embedded gasket fitted with heat treated bakelite for terminals block and PVC Glands for cable entry complete all as directed 109 M&L Three core 1.5sqmm(nominal area)service wire PVC insulated copper conductor FRLS, multi stranded, unsheathed 1100 volts grade IS-694 marked andfrom junction box to street light fitting through steel pole withPVC conduit & necessary clamps, bolts & nut etc required for fixing complete all as specified and directed. 110 Supply , install, testing and commissioning of cubical housing cabinet type conforming toCPRI approved LT panel board outdoor type, platform mounted factory made dust proof, weather proof powder coated totally enclosed dust and vermin proof openablefrom both front and rear side made of3.15 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer.The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowings :-System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -200 Amps , cable entry (incomming and outgoing ) form bottom with cable gland Incomming : 125 Amps MCCB FP,35 KA, 415 Volts, 50 Hz-01 No (Incoming from CSS)Outgoing -(a) MCCB 4 pole 100 Amps 25 kA - 02 Nos (for signal unit and 1 standby)(b) MCCB 4 pole 16 Amps 25 kA - 2 Nos (For OFFR Living ,meter or switch house and and 01 No for street lights)(c)Timeswitches astro type 250V sigle phase of 20 Amp rating with contactor(d) Digital volt meter (size -96x96mm) 0-500 volts with selector switch -01 Nos(e) Digital Ammeter (Size 96x96mm) with selector switch incl CT (500/5 Amp) with all connection -01 No (f) LED indicating lamps -03 Nos 111 Supply , install, testing and commissioning of cubical housing cabinet type CPRI approved LT panel board outdoor type, platform mounted factory made dust proof, weather proof powder coated totally enclosed dust and vermin proof openablefrom both front and rear side made of3.15 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer.The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowing:- System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -400 Amps , cable entry (incomming and outgoing ) form bottom with cable glandIncomming : 250 Amps MCCB FP,35 KA, 415 Volts, 50 Hz-01 No(incoming from CSS)Outgoing -(a) MCCB 4 pole 200 Amps 35 kA - 01 Nos (Adm buidling)(b) MCCB TPN 16 Amprs 25 KA-02 Nos (Guard house and standby)(c) Digital volt meter (size -96x96mm) 0-500 volts with selector switch -01 Nos(d) Digital Ammeter (Size 96x96mm) with selector switch incl CT (500/5 Amp) with all connection -01 No(e) LED indicating lamps -03 Nos. 112 Supply , install, testing and commissioning of cubical housing cabinet type CPRI approvedLT panel board Outdoor type, platform mounted factory made dust proof, weather proof powder coated totally enclosed dust and vermin proof openablefrom both front and rear side made of3.15 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers.The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowing:-System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -600 Amps , cable entry (incomming and outgoing ) form bottom with cable glandIncomming : 315 Amps MCCB FP,35 KA, 415 Volts, 50 Hz-01 No(incoming from CSS)Outgoing -(a) MCCB 4 pole 125 Amps 35 kA - 03 Nos(02 Nos for OR Accomodation and 01 Nos standby)(b) MCCB 4 pole 63 Amps 25 kA - 01 Nos(JCO Accomodation and JCO Club) (c) MCCB 4 Pole 25 Amprs 25 KA - 01 Nos (Drying and ironing room)(d) MCCB TPN 16 Amprs 25 KA - 02 Nos (Street lights and one standby)(e) Digital Ammeter (Size 96x96mm) with selector switch incl CT (500/5 Amp) with all connection -01 No (f) Digital volt meter (size -96x96mm) 0-500 volts with selector switch -01 Nos (g) LED indicating lamps -03 Nos (h)Timeswitches astro type 250V sigle phase of 20 Amp rating with contactor 113 Supply, install, testing and commissioning of Automatic Power Factor Correction (APFC) panel board of aggregate capacity 15 KVAR suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz, outdoor type, cubicle, floor mounted, free standing dust and vermin proof, air ventilation made out of 3 mm thick CRCA sheet duly powder coated, Manufactured shall be CPRI norms and as approved by GE, factory made.Panel board shall have front and rear opening with hinged type doors and rubber gasket, handles, industrial type locking arrangement, cable alleys, switch gear compartment, bottom cable, entry holes for incoming and outgoing cables, earthing terminals, danger notice plate, Aluminum bus bar duly covered with heat shrink sleeves of colour coded duly fixed on DMC / SMC insulators housed in a separate bus bar chamber including control wiring with PVC insulated, flexible, multistranded copper conductor cables of adequate size and of adequate length for connecting of capacitors, contactors etc duly ferruled crimped with suitable lugs / thimbles and including connecting of incoming and outgoing cables. Panel board shall be mounted on and including MS angle iron frame of suitable size duly painted and PCC1:2:4 type B1 for foundation / Platform to suit the site requirement complete all as specifiedand directed and comprising of following:-(i) APFC relay microprocessor based digital display type of 9 stages suitable for operation of PF upto unity – 01 No. 114 (ii) MCCB 320 Amps, 4 pole, 50KA, 415V, 50HZ – 01 No for incoming.(iii) MCCB 80 Amps, 4 pole, 25KA, 415V – 03 No’s for capacitor outgoing.(iv)MCCB 40 Amps, 4 pole, 25KA, 415V – 01 No for capacitor outgoing.(v)MCCB 16 Amps, 4 pole, 25KA, 415V – 05 Nos for capacitor outgoing(vi) MCB SP 0.5 to 5 AMPS, ‘C’ Curve, 240V-09 Nos as per circuit control.(vii) Capacitor Bank 2 KVAR, 3 phase, 440V MPP type including suitable rating contractor -05 Nos.(viii) Capacitor Bank 2 KVAR, 3 phase, 440V MPP type including suitable rating contractor -02 Nos.(ix) Capacitor Bank 1 KVAR, 3 phase, 440V MPP type including suitable rating contractor -01 Nos. 115 (x) LED indication lamps RYB – 01set.(xi) Auto / manual selector switch -01No.(xii) Push button and indication lamp for each capacitor bank -01 set.(xii) Digital voltameter with selector switch -01set.(xiv) Digital ammeter with selector switch & CT’s -01.(xv) Aluminium bus bar TPN 480 Amps rating -01 set.Note: The contractor should be factory inspection and drawings approval by the GE / Engineer-in-Charge before procurement after commissioning of APFC panel the power factor (PF) to achieve 0.95 to 0.99 mandatory at any load condition automatically. 116 Supply and fix solar street light smart integrated solar system all in one with MPPT (Maximum Power Point Tracking) charge controller ,Tilable LED Panel,Adjustable AIO mounting angle ,mono crystalline solar panel ,PIR motion sensor, and 6m tubular pole with 30 wattLED light at a rate 100 lm/w, 60wp, 75 AH (Lithium ferrous phosphate battery luminaries must have a life of greater than 50,000 hours and have IP 66 rating, the modules are to bedesigned to with stand corrosive atmosphere and heavy wind loads. the modules are to be certified for standers IEC 61215, IEC 61730 (Safely class I & II) complete all as specified and directed. 117 Supply and fix LED post top lantern decorative typeo fttings for 360 degreee indirect light on pillars of capacity 40 watts high pressure die cast aluminium housing IP 65 rating, suitable fr mounting 40 dia GIlight grade pipe upto 0.5 m long or required length including nuts and bolts and fixed complete all as specified and directed.Model No : RUBYPT40WLED757PSYMTOPC OF MAKE : Havels or equivalentmake as per Appendix D 118 M&L fpr boring holes horizontally under road without damaging the surface of road (minimum 1 mtr below the road surface/ footpath with the help of GI tubing not exceeding 100mm dia bore for passing of UG cable complete all as specified and directed. 119 (REFGIGERATION & WATER COOLER) Supply, installation, commissioningofrefrigerator single door, electric driven (single phase) 230V AC, 50 Hz, 308 - 315 ltrs capacity, conforming to IS 15750 (2006) for frost free, with power saver compressor with minimum BEE 5 star rating complete all as specified and as directed. 120 Supply, installation, commissioningofrefrigerator single door, electric driven (single phase) 230V AC, 50 Hz, 192 - 210 ltrs capacity, conforming to IS 1476 for direct cool with power saver compressor with minimum BEE 5 star rating complete all as specified and as directed. 121 Supply, installation, commissioning of Metal Top Deep Freezer single phase 240 volt, 50 Hzminimum capacity 320 ltrs, BEE 5 star rating complete all as specified and directed. 122 Supply, installation, commissioning of Metal Top Deep Freezer single phase 240 volt, 50 Hzminimum capacity 400 ltrs, BEE 5 star rating complete all as specified and directed. 123 Supply, installation, commissioning of Water cooler fullystainless steel, electric driven single phase having approx storage capacity of 80 Ltr and nominal cooling capacityof 40 Lts per Hour as per latest IS 1475 and BEE 5 star ratingcomplete all as specified and directed. 124 Supply, installation, commissioning of Water cooler fullystainless steel, electric driven single phase having approx storage capacity of 120 ltr and nominal cooling capacityof 60 Lts per Hour as per latest IS 1475 and BEE 5 star ratingcomplete all as specified and directed. 125 S & F Voltage stablizer of capacity 2 KVA for automatic operation, single phasewith neutral, air cooled indoor type and disign defore input Voltage variation between 170 Volts to 250 Volts with output Voltage stabiilized at 230 Volt with accuracy of + 2.5% complete all specified and director. 126 S & F Voltage stablizer of capacity 1 KVA for automatic operation, single phasewith neutral, air cooled indoor type and disign defore input Voltage variation between 170 Volts to 250 Volts with output Voltage stabiilized at 230 Volt with accuracy of + 2.5% complete all specified and director. 127 (DG SET) M&L Earthing complete with galvanised steel earth plate electrode 60cm×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not lessthan 1.5 metres below normal ground level, connected tousing galvanised iron strip 32×6mm as earthing lead earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated by Engr-in-charge including testing on completion. 128 Supply and installation testing and commissioning silent Diesel Enginegenerating set 415 volts 40 KVA3 phase 0.8 power factor, 50 Hz, 1500RPM self exicited self regulated brushlessAC generator installed including AMF panel,suitable for ambient condition at Panagarh and confirming to condition under ISO 3046, IS:10001/ 10002,BS 5514/5000 with capacity of 10% overloading for one hour in every twelve hour duration and including the following accessories :- (A) Alternator:- Synchrounous alternator rated at 40 KVA suitable for continuous operation at 1500 RPM generating 415 volts at 0.8 p.f (lag) suitable for 50 Hz, three phase, 4 wire system.The alternator shall be brushless, single bearing, self excited/ self regulated with an AVR. The alternator will be suitable for climate and shall generally confirm to IS: 4722 :2001. The salient features of the alternators are :- (a) +-1% voltage regulation (max) in static conditions.(b) IP:23 protections with class H insulation.(c) Permanent lubricating bearing. 129 (B) Diesel Engine:- Adquate capacity of diesel engine water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500RPM, as per relevant IS/BS complete with standard accessories. (C)ACOUSTIC ENCLOSURE : Acoustic enclosure shall be powder coated and fabricated out of 16 SWG CRCA MS sheet. The silent (to comply GRIHA and other agencies norms) canopy shall be of nut bolt type construction. Critical processes of punching is done on CNC machines to maintain dimentional accuracy of holes within 0.1 mm.Powder coating is done after seven-tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE-RETARDANT foam as acoustic material & Rock wool for hot zone.Adequate hinged doors shall be provided to canopy, one door shall have glass window for control panel visibility (D) AMF panel : Automatic Mains Failure (AMF) panel made of CRCA sheet of 2 MM thick including necessary arrangement to install, testing and commissioning & connecting ot load cable to up ot changeover switch, suitable capacity of 4 pole MCCB complete all as per OEM recommendation.(E) Civil Works :- All civil works including PCC platform and related foundations incl for panel and equipments incl making goodof disturbed area during installation and commissioning of genset. The depth and size of the foundation and PCC as recommendedby the manufacturer. 130 (F) AMF Panel Specification shall be as per manufacture instruction.Note :-The contractor shall be arrange for artificial load resistive for testingof DG set at site and the cost is deemed to be included in the quoted ratesMAKES :- Make of engine : CUMMINS/KIRLOSKARGREEN/ASHOK LEYLAND/ GREAVES COTTON.Make of alternator : KIRLOSKAR GREEN / ALSTOM / CROPTON GREAVES /SIEMENS 131 Supply, erecting,testing aand commissioning of solar water heating system with heat exchanger for cold & warm regions respectively with solar evacuated tube collection conforming to IS : 12933 (Part - i ) with amdt No 1 and IS : 12933 (Part 2) /2003 suitable for inlet water with chlorine and fluorine content up ot 100 ppm and supply hot water at the outlet of 200 litters capacity with elctrical back up meeting specifications as under and comprising of followings :-Supply and fixing rotational moulded polyethylene water storage tank (Cylindrical Vertical with closed lockable top with lid and locking arrangement) hoisted and fixed in position all as specified in SSR Part -I of capacity 200 Litters complete for storage of cold water feeding to solar water heater, including staging made out of MS Angle iron 50x50x6 mm all as specified and directed at site by Engineer-in-Charge.Material :- Soalr water heating System : Comprising of solar Evacuated tube Collector, Collectors stand assembly.Staniless steel insulated hot water Storage tank with heat exchange and various other components . Solar evacuated tube collector component shall have :Evacuated tube collector component shall have : solar Evacuated tube collector cover plate made of toughened glass.Sheet for absorber made of copperAbsorber made of copper sheet and copper tube.the minimum thickness of Aluminium shall be as under:- (a) Channel section for sides 1.6mm (b) Sheet for bottom 0.7 mm (c) Support for glass retaining 1.2 mm sheet for entire body 1.0 m AbsorberAbsorber shall consist of riser, header and sheet for absorer. The diameter of header shall be 25.4 +/- 0.5 mm and thickness 0.71 mm. The Diameter of riser shall be 12.7 +/- 0.5 mm and thickness 0.56 and made of copper only. 132 S & F Hot water pipe duly insulated with glass wool and aluminium cladding 20 mm bore complete all as specified and directed. 133 Rain water Harvesting /Recharge PitS & F 150 MM perforated UPVC pipe with 20% Perforation complete all as specified and directed. 134 S & F 150mm bore PVC (SWR) vent cowl complete all as specified and directed. 135 M&L for hand packed gravel (Stone chips 12.50mm) for filling in bore holes and inside of recharge pit complete all as specified and directed. 136 Boring for 350 Mm Dia bore to a depth of 40 mtr in soil and getting out and disposal of spoil to a distance of 50 mtr using DMC method ( Direct mud Circulation) complete all as specified and directed. 137 GRIHA RATING FOR FOLLOWING BUILDING:-Minimum 3 star GRIHA rating shall be obtained for the following buildings which includes pre-certification and final ratings from approved aggency(a) OFFICER/ ADMIN BLOCK (b)SINGLE living JCOs ACCN(c) SINGLE living HAV/OR ACCN (T/S)Note :- 01The GBA (Green Building adviser) ofr obtaining GRIHA certification shall be approved by Accepting Officer.02. The GBA shall be responsible for all necessary actions for obtaining final GRIHA rating as per following guide lines:- (a) Pre-Cretification :-1. Submission of GRIHA per certification documents to certification agency as applicable immediately after the issue of Job/Work order.2. Analysis and suggest improvement/correction in the MEP/Other relevant drawings/documents and draft tender of the subject work for GRIHA star Rating (Min Three Star).3. Preparation, Submission & uploading all the documents in accordance with the GRIHA requirment, documentation shall be supported by drawings, test result quipment catalogues & calculations.4. Selection of equipment & material.5. To facilitate the planning team for selection of appropriate energy efficient & eco -friendly technologies, equipment & materials for the building e.g lighting system ,white goods, water treatment technologies, renewable energy, nontoxic paints, rapidlly renewable materials, recycled materials, ecofriendly materials etc.6. preparation of vendors & suppliers list for inclusion in the tender & working out specification of equiptment & materialto suit the GRIHA requirement. 138 7. Develop templates for GRIHA calculations to achieve certain points, this include materials related criteria, construction of waste management at site, energy calculation etc.8. conduct solar path analysis for each to achieve the best design ( shading device, Orientation etc.)9. Conduct solar path analysis for each fenestration to achieve the best design ( shading device, orientation etc)10 Perform day light analysis to ensure optimun condition achieved as per the guidelines provided by ECBC 2007.11. Perform day light analysis for window -wall ration, glass peropertiies (SHGC) & Providing recommendations to meet the compliance of ECBC 2007.12. Perform hourly calculation to show that thermal comfort condition as well as non-condition area are cachieved.13. Perform energy simulation to predict the energy performance of energy system in the bldg is less than the benchmarked energy perfomance as prescribed by GRIHA.14. Submit of ECBC compliance document to show that compliance fo mandatory requirment of ECBC are meet.15.Submission of draft specification to comply with relevant criteria of GRIHA for inclusion in tender documents.16. Liasoning and coordinating with GRIHA team for registration of project, uploading relevant document. Responding ot queries, observations, modification and corrections given by GRIHA team within specified time framed and reporting client with lates update.17. completion of all documentation requirement and formatlities before conclusion of main bldg. Contract and obtaining pre-certification with 3 or above star rating. 139 Final Rating:-Acquiring of Final Post GRIHA (minimum 3 star rating) certification approval from GRIHA including changes in drawings/ design during execution of work.Note:-The consultancy fees is inclusive of the following:-1. Pre-certification Registration Fees2. Certification registration Fees3. Site visit of GRIHA Official4. Site visit of GRIHA Official5. Third party EvaluatorPayment Schedule :-(i) 10% after pre-certification(ii) 50% at finalisation of specification(iii) 40% after obtaining GRIHA certification 140 Providing and fixing white vitreous china floor mounted water closet of size 360X640X685 mm of approved shape including providing and fixing vitreous china cistern with duel flush fitting, of flushing capacity 3 litre/6litre (adjustable to 4litre/8litre, including seat cover, and cistern fitting nuts, boltsand gasket etc complete all as specified and directed.Model No: SLS-WHT--6851P of make Jaquar of equivlent make/model as specified in Appendix D. 141 Providing and fixing white vitreous china wash basin for under counter mounting, specially fabricated brackets, painted whit, brass tap, 32 mm C.P. Wast, 15mm C.P. Brass self closing tap, connection pipe & rubber adopter for waste connection, complete including cutting and making food the walls, wherever requird complete all as specified and directed.Cat No : CNS_WHT_705 for wash basin ofmake Jaquar& Cat No PRS-031 for 15mm C.P brass tapof make Jaquar or equivlent make/model as specified in Appendix D. 142 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. Size 485 X 310 X 710 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitablebrackets all as per manufacturers specification and direction of Engineer-in-Charge.Cat No : URS-WHT-13255 of make of equivlent make/model as per Appendix D 143 Providing and Fixing of P.V.C waste Flexible pipe 40mm dia for sink and Urinal including PVC waste fittings complete including cutting and making good the walls, wherever required complete all as specified and directed 144 Providing and Fixing of P.V.C waste Flexible pipe 15mm dia for sink and Urinal including PVC waste fittings complete including cutting and making good the walls, wherever required complete all as specified and directed 145 Providing and fixing C.P. Brass angle valve 15mm dia for basin mixer and gyser pointsconforming to IS : 8931 complete all as specified and directedCat No FLR-CHR-5053N of make of equivlent make / model as per Appendix D. 146 Providing & fixing Liquid soap container of standard shape with bracket of the same material with snap fitting of approvedquality and colourcomplete all as specified and directedCat No : CAN-1135N of make of equivlent make / model as per Appendix D 147 Provinding & fixing Sink cock 15mm nominal bore of approved quality and colour complete all as specified and directedCat No : FLR-5347ND of make of equivlent make / model as per Appendix D 148 Provinding & fixingCP Brass Health faucet with 1.5M S.S Flexible Tube with wall hook including screw, Nut, bolts, cutting wall/floor and making good the same whatever required complete all as specified and directedCat No : ALD-CHR-583 of make of equivlent make / model as per Appendix D 149 Provinding & fixingCP Brass Bid cock Including wall fange, Connections, screws, nut, bolts, cutting wall/floor and makiing good the same whatever requiredcomplete all as specified and directedCat No : FLR 5037Nof make of equivlent make / model as per Appendix D 150 Provinding & fixing sink CP Wall mount double Robe Hookfixed to wooden cleats with C.P Brass screws, cutting wall/floor and making good the same whateverrequired complete all as specified and directedCat No : CAN-1161N of make of equivlent make / model as per Appendix D 151 Providing and fixing of straight type Macfit Single body push fit type WC pan connector with factory supplied srpring loaded seal guard of mcalpine, UK with integral single mould sealing fins made of flexible eva body, including bush/ adaptor for use with C.I pipe as supplied with the pan connecrtor complete all as specified and directed. Model : MAC 1 of make Macalpine of equivlent Model as approved by E-In-C or Accepting officer. 152 HOT WATER SUPPLYSupply, installation, commissioning and testing of water heater storage type, electric driven, capacity of 15 litres, single phase, 230V AC 50 Hz, closed type ISI marked vertical wall mounting, with steel body cover and Copper inner container, BEE 5 star rated. Complete with all accessorios such as safety valve thermostat connection pipe complete all as specified and directed. 153 Supply, installation, commissioning and testing of water heater storage type, electric driven, capacity of 25 litres, single phase, 230V AC 50 Hz, closed type ISI marked vertical wall mounting, with steel body cover and Copper inner container, BEE 5 star rated. Complete with all accessorios such as safety valve thermostat connection pipe complete all as specified and directed. 154 S&F CP Brass stop cock (concealed) of 100mm dia of standand design conforming to 15:8931 complete all as specified and directed. 155 Providing and fixing sound insulated PP piping system as per ON EN 1451 _ Part I-6 & EN 12056 part I-5 with 3 Layer pipe made of PP-C +PP-MV+PP-C in Blue Ral 5014 (Halogen and calcium free) colour, Push-fit type, food safe having high impact and stiffness, offering sound level of not more than 22dBA at a flow rate of 4 I/S and having pipe ring stiffness as per ISO/DIS 9969 and tightness as per EN 1277/B and C and DIN 19560 with all necessary fillings in blue colour, filled with factory fitted lip ring of make : Polyplast or equivalent make as approved by GE suitable for PP110mm dia Pipes complete all as specified and directed. 156 All as per item No 14.24 here-in-after but for PP 75mm dia pipes 157 All as per item No 14.24 here-in-after but for PP 40/50mm outer dia meter pipe (For wash basin etc) 158 Providing and fixing floor trap with minimum 50mm water seal with rubber seal on inlet to push fit hopper for indirect waste connection, 110mm inlet& 110m outlet long hight complete all as specified and directed. 159 Providing and fixing 110 X 50mm UPVC Floor Drain / Plain Floor trap complete all as specified and directed. 160 Providing and fixing SS Grating Over Floor Trap& Floor Drain 127 X 127mm complete all as specified and directed. 161 M&L concrete bed to drain pipe including packing under and lacking against the side of pipe after they are laid and tested with PCC (1:4:8) type D-2, for 110mm dia complete all as specified and directed. 162 All as per srl item No 14.30 here-in-after but for PP 40/50mm outer dia meter pipes. 163 S&F clean out cap plug (FCO/COP) for cleaning of same materials (POLO KAL NG) for PP 110mm dia complete all as specified and directed. 164 S&F 3-layer PPR-polypropylene random copolymer conceled pipes SDR 7.6 (PN-16) UV stabilized and antimicro bial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fitting for 50mm outer dia laid in trinches complete all as specified and directed.
Contract Date: Mar 17, 2026 Contract Value : 59.85 Crore
Statutory Bodies & Commissions/Committees No of Bidders 5
West Bengal View Result →
42.
Railways #9804493 AOC
Supply Of hydraulic Wheel Press 500 T Capacity To Dismount Wheels,Design, Manufacture, Supply, Testing Of 500 T Hydraulic Wheel Dismounting Press With Comp Uter Based Measuring And Recording System As Per Els/Ed Specification No. Rs/Ed/M&P/388-Mw And Drawi Ngs Enclosed. Note: Firm Should Have Supplied And Successfully Commissioned 500 T Capacity Wheel Press Item To Any Of The Indian Railways, The Proof Of Successful Commissioning And Its Performance Report From C Ompetent Authority Should Be Attached Along With Tender, Other Wise Offer Will Not Be Considered. [ Warra Nty Period: 24 Months After The Date Of Delivery ] ] , Cost Of Concomitant Accessories According To Clause 4.1 Of The Tender Specifications Docume Nt. ] , Cost Of Any Other Accessories Which In The Opinion Of The Supplier Is Essentially Required For M Aking The Machine Fully Functional. ] , Camc Charges For Five Years Starting After 2 Years Of Warranty Period, As Per Clause 24 Of Bid Document. [ Warranty Period: 2 Years, Amc Period: 5 Years, Rate Of Discounting: 10 % ] ] At (Location) Sr.Dee/Rs/Els/Ed, Sr Tamil Nadu 1.00 Numbers 5 6579Ns04 Optional Non Stock --- No Consignee Inr (G1) Spares (Y) Cost Of Optional Accessories With Breakup Of Individual Items ] Consignee Sr.Dee/Rs/Els/Ed, Sr Tamil Nadu 1.00 Set 6 6579Ns05 Optional Non Stock --- No Consignee Inr (G1) Spares (Y) Cost Of Spares Required For Two Years Period Of Warranty. ] Consignee Sr.Dee/Rs/Els/Ed, Sr Tamil Nadu 1.00 Set 7 6579Ser1 Essential Non Stock --- Yes Consignee Inr (G1) Services (Y) Turnkey Charges Namely Foundation, Installation And Commissioning Of Hydraulic Wheel Press 500 T Capacity. ] At (Location) Sr.Dee/Rs/Els/Ed, Sr Tamil Nadu 1.00 Numbers 8 6579Ser2 Essential Non Stock --- Yes Consignee Inr (G1) Services (Y) Cost Of Preventive Maintenance During 1St And 2Nd Years Of Warranty Period As Per Clause 2 3.3. ] At (Location) Sr.Dee/Rs/Els/Ed, Sr Tamil Nadu 1.00 Numbers 3. T And C F.O.R Description Destination Delivery Period Description Delivery /Completion Rate Of Supply For All Items Commencement : Within 4 Months Of Issue Of Contract, However, Delivery Completion : Within 6 Months Thereafter Period Shall Not Exceed No. Of Days As Mentioned In Delivery Schedule Chart Of Para 7 Of Section Iv Of Bid Document Part Ii. However, The Delivery Period Indicated Being Tentative, May Vary At The The Time Of Placement Of Order. Payment Terms S.No Description Payment Terms 1 1) 60% Payment: Upon Receipt Of The M&P (Includes Covered Shed, Linkage Of Track, Inside Shed, Outside Shed, Power Supply Connection, Provision Of Toilets With Urinal Facility Along With Septic Tanks), Duly Pre- Inspected By A Third -Party Inspection (Tpi) Agency, Receipted At The Site By The Consignee In Good Condition And Submission Of A Joint Receipt Note. 2) 20% Intermediate Payment: After Successful Installation And Commissioning And Submission Of A Joint Commissioning Note. 3) Final 20% Payment: After Commissioning Of The M&P At The Consignees End For A Minimum Period Of 30 Days, Upon Submission Of A 10% Warranty Bank Guarantee And A Proving Test Certificate Statutory Variation Clause Page 2 Of 13 Run Date/Time: 21/03/2025 12:41:51Stores/Southern Rly Tender Document Tender No 16245016 Closing Date/Time 26/05/2025 14:30 S.No Description 1 Statutory Variation In Taxes And Duties, Or Fresh Imposition Of Taxes And Duties By State/ Central Governments In Respect Of The Items Stipulated In The Contract (And Not The Raw Materials Thereof), Within The Original Delivery Period Stipulated In The Contract, Or Last Unconditionally Extended Delivery Period Shall Be To Railways Account. Only Such Variation Shall Be Admissible Which Takes Place After The Submission Of Bid. No Claim On Account Of Statutory Variation In Respect Of Existing Tax/Duty Will Be Accepted Unless The Tenderer Has Clearly Indicated In His OffEr The Rate Of Tax/Duty Considered In His Quoted Rate. No Claim On Account Of Statutory Variation Shall Be Admissible On Account Of Misclassiï¬Cation By The Supplier/ Contractor. Standard Governing Conditions S.No Description 1 The Bidder Agrees To Supply The Tendered Stores At The Rates Quoted By Him In Accordance With The Latest Version Of Irs Conditions Of Contract (Attached As Irs Conditions Of Contract To This Tender Document For Ready Reference) And Southern Railway Tender Conditions (Attached As Sr Tender Conditions To This Tender Document For Ready Reference). 4. Eligibility Conditions Special Eligibility Criteria S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Supply To Be Strictly As Per Speciï¬Cations Normal Applicable To Yes Yes Not Allowed Document Uploaded With This Tender. All Bidders Please Refer Section V Of Document Titled Specification For Hydraulic Wheel Press Cap 500 T. 2 As Per Bid Document Eligibility Criteria. Normal Applicable To Yes Yes Allowed All Bidders (Mandatory) 3 Preferably Manufacturers Should Normal Applicable To Yes Yes Allowed Participate. Participating Traders/Agents All Bidders (Optional) Must Attach Authorization Letter Issued By The Oem Or Oem Authorized Stockiest Along With Their OffEr. Authorization Letter Should Preferably Be Tender Speciï¬C. In Case Of General Authorization Letter, It Must Clearly Indicate The Validity Period/Expiry Date. OffErs With General Authorization Letter Silent On Validity Period/Expiry Date Will Not Be Considered For Placement Of Order And That OffEr Is Liable To Be Ignored. (Please Refer Para 3.4 Of Part B Of Sr Tender Conditions). 4 Procurement Of The Item Is Restricted To Normal Applicable To Yes Yes Not Allowed Local Suppliers With Minimum Local All Bidders Content Of 20% (Class-I Or Class-Ii Local Supplier As Deï¬Ned In Railway Board Letter No.2020/Rs(G)/779/2/Pt.1 Dated 25.09.2020 With Latest Amendments, If Any) Only And The Vendors Who Do Not Qualify To Be Local Suppliers (I.E.), Non- Local Suppliers With Local Content Less Than 20%) Should Not Quote In The Tender As Their OffErs Shall Not Be Considered For Any Ordering. In Case Any Vendor Who Does Not Qualify To Be A Local Supplier For The Tendered Item Participates In The Tender, It Does So At Its Own Risk And Cost And Railways Shall Not Be Liable For Any Loss Or Damage Caused To The Vendor. OffEr Of The ϬRm Shall Be Summarily Rejected In Case Of Non-Compliance Of Above Declaration. For More Details, The Tenderer Shall Refer Para 16.0 Of Part B Of Sr Tender Conditions Attached To This Tender Document. Page 3 Of 13 Run Date/Time: 21/03/2025 12:41:51Stores/Southern Rly Tender Document Tender No 16245016 Closing Date/Time 26/05/2025 14:30 5 Earnest Money Deposit (Emd) Shall Be Normal Applicable To Yes Yes Not Allowed Deposited By All Vendors For Tenders With All Bidders Estimated Value Above Rs.25 Lakhs Subject To The Applicable Exemptions. The Para 2.1 Of The Part A Of Sr Tender Conditions With Regard To Emd Exemption Is Superseded As Below And The Conditions Mentioned Here Below Will Prevail Over That Of In Para 2.1 Of The Part A Of Sr Tender Conditions Attached To This Tender Document: Emd Amount Shall Be Mentioned In All Tenders Irrespective Of The Nature Of Tender As Per The Emd Amount Mentioned In Clause 2.3 Of Part A Of Sr Tender Conditions Or As Decided By The Purchaser Under The Policy. There Shall Be No Exemption From Submission Of Emd For Any Tender Or By Any Tenderer Subject To Provisions Under Clause 10.4.3 Of Part A Of Sr Tender Conditions Except Following : (I) Emd Shall Normally Not Be Called Against Tenders With Estimated Value Up To Rs.25 Lakhs (Including Single Tenders, Global Limited Tenders) Except Cases Where Competent Authority Incorporates The Condition To Call For Emd. Ii) Public Sector Undertakings (Psus) A. Psus Owned By Ministry Of Railways And B. Psus For The Group Of Items That Are Manufactured By Them. Iii) Mses Registered Under Udyam Registration Shall Be Eligible For Exemption From Payment Of Emd Irrespective Of Relevance Of Product Category For Which They Are Registered With Udyam. However, Traders/Distributors/Sole Agent/Works Contract Are Not Exempted From Payment Of Emd As They Are Excluded From The Purview Of The Policy. Iv) Other Railways, Indian Ordinance Factories And Govt. Departments. V) In Exceptional Cases, Where Emd Exemption Is Speciï¬Cally Incorporated In Tender Conditions. Vi) Vendors Registered With Southern Railway For The Trade Group/Trade Groups Of The Tendered Item . Vii) Regular And Development Vendors Appearing On The Approved Vendor Lists Of Rdso/Pus/ Core Etc., For Those Speciï¬C Item For Which They Are On The Approved List, Subject To Approval Status Being Valid On The Date Of Tender Closing. Viii) Vendors Registered With Railways For Supply Of Medicine, Medical Equipments And Consumables Shall Be Exempted From Submission Of Emd For These Items. Ix) In Tenders Issued Against Pac, Oem In Whose Favour Pac Has Been Issued Shall Be Exempted From Submitting Emd. Kvic And Acash Shall Be Exempted From Emd For Items Supplied By Them. In Case Of Submission Of Earnest Money Deposit In The Form Of Bank Guarantee, Please Refer Annexure- 6 Of Sr Tender Conditions For The Proforma For Bg. Page 4 Of 13 Run Date/Time: 21/03/2025 12:41:51Stores/Southern Rly Tender Document Tender No 16245016 Closing Date/Time 26/05/2025 14:30 6 All The Tenderers Shall Have To Submit Normal Applicable To Yes Yes Allowed Clause-Wise Compliance Of Speciï¬Cation All Bidders (Mandatory) Mentioned In Bid Documents Part I & Part Ii And Drawings Enclosed Along With This Tender Or Product Catalogue For The Make And Model OffEred Should Be Submitted By The Tenderer, Spelling Out Deviations, If Any, To Ascertain Technical Suitability. An OffEr, Whose Technical Suitability Cannot Be Ascertained, May Be Liable To Be Ignored. 7 Inter - Se Position Of Offers Would Normal Applicable To Yes Yes Not Allowed Be Determined Based On The Sum Of All Bidders Cost Of The Equipment, The Cost Towards Comprehensive Annual Maintenance Contract For 5 Years (With Npv Factor) Following Free Comprehensive Warranty For 2 Years, Cost Of Concomitant Accessories, Cost Of Any Other Accessories Which In The Opinion Of Supplier Is Essentially Required For Making The Machine Fully Functional , Cost Of Preventive Maintenance For 2 Years, Cost Of Turnkey Charges Viz., Foundation, Installation & Commissioning Etc. (Excluding Cost Of Optional Accessories, Spares For Two Years Of Normal Maintenance And Consumables.) 8 Firms Have To Quote Cost Of Basic Normal Applicable To Yes Yes Not Allowed Machine, Concomitant All Bidders Accessories/Equipment, Essential Spares, Optional Accessories, Essential Services, Amc Service, Training Etc. It Is Mandatory To Submit OffErs Against All These Items, Otherwise OffEr Will Not Be Considered For Inter-Se Ranking. However, Please Note That Cost Of Optional Accessories Shall Not Be Included In The Basic Price Of The Machine For Inter-Se Ranking. 9 In Case Of Procurement For A Value Normal Applicable To Yes Yes Not Allowed Exceeds Rs. 10 Crores, The Class- I Local All Bidders Supplier Shall Be Required To Provide A Certiï¬Cate From The Statutory Auditor Or Cost Auditor Of The Company (In The Case Of Companies) Or From A Practicing Cost Accountant Or Practicing Chartered Accountant (In Respect Of Suppliers Other Than Companies) Giving The Percentage Of Local Content, Failing Which OffEr Will Be Summarily Rejected. 5. Compliance Conditions Check List S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Have You Quoted Cost Of Basic Machine, Normal Applicable To No No Not Allowed Concomitant Accessories/Equipment, All Bidders Essential Spares, Optional Accessories,Essential Services, Amc Service, Training Etc. It Is Mandatory To Submit OffErs Against All These Items, Otherwise OffEr Will Not Be Considered For Inter-Se Ranking. 2 Have You Attached Documents To Prove Normal Applicable To No No Not Allowed Your Eligibility And Past Performance As All Bidders Per Tender Requirement? Page 5 Of 13 Run Date/Time: 21/03/2025 12:41:51Stores/Southern Rly Tender Document Tender No 16245016 Closing Date/Time 26/05/2025 14:30 3 Have You Attached Certiï¬Cation Of Local Normal Applicable To No No Not Allowed Content From Statutory Auditor/ Cost All Bidders Accountant? 4 Have You Quoted Warranty Oblications As Normal Applicable To No No Not Allowed Per Tender Requirement? All Bidders 5 Have You Quoted Delivery Period Correctly Normal Applicable To No No Not Allowed And Precisely? All Bidders 6 Have You Uploaded Annexure A As In Normal Applicable To No No Not Allowed Section Vi, Complete In All Respect? All Bidders 7 Have You Submitted All Supporting Normal Applicable To No No Not Allowed Documents Required? All Bidders 8 Have You Read The Security Deposit (Sd) Normal Applicable To No No Not Allowed Condition At Para 10 Of Part A Of Sr All Bidders Tender Conditions Attached With This Tender Document And Uploaded Relevant Document For Seeking Exemption From Submission Of Sd? If Not, Are You Ready To Pay Security Deposit? 9 Are You Coming Under Mse Status Given Normal Applicable To No No Not Allowed As Per Guidelines Issued By Railway Board All Bidders For Purchase Preference Vide Letter No. 2010-Rs [G] -363-1 Dt. 05.07.2012 Or Latest. If Yes,Have You Attached Valid Documents (Udyam Registration Certificate) Towards Being Mse? 10 Have You Furnished The Statement Of Normal Applicable To No No Not Allowed Deviations?[Preferably Nil] All Bidders 11 Have You Quoted The Discount If Any In The Normal Applicable To No No Not Allowed Specified Column Only In Ireps? All Bidders 12 Have You Furnished Bank Account Details Normal Applicable To No No Not Allowed Such As Name Of The Bank And Address, All Bidders Account No., Micr, Ifsc Code And Type Of Account To Facilitate Eft Payment? 13 Please Check Our Website Before Normal Applicable To No No Not Allowed Submitting OffEr, Whether Any All Bidders Corrigendum To The Tender Has Been Issued Or Not. 14 Firm To Indicate Make-Model-Brand Normal Applicable To No No Not Allowed Offered, If Any. All Bidders 15 Have You Kept Your OffEr Valid For 120 Normal Applicable To No No Not Allowed Days? All Bidders Commercial-Compliance S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 In Case Of Road Delivery, The Date Of Normal Applicable To Yes Yes Not Allowed Delivery At Destination [Consignees End] All Bidders Shall Only Be Treated As Delivery Date Irrespective Of F.O.R. / F.O.T. Condition Mentioned Elsewhere In The Contract / Tender. 2 Tenderers May Note That Their OffEred Normal Applicable To Yes Yes Not Allowed Delivery Schedule Should Clearly Indicate All Bidders The Starting Time, Quarterly Rate Of Supply And ϬNishing Time. For OffErs With Vague Delivery Schedule Like -02 To 12 Months- Or Like -06 To 10 Months-, Delivery Period Shall Be Given As Per The Requirement Best Suited To This Oï¬Ƒce Within The Quoted Range. 3 The Bidder Conï¬Rms That Rates And Other Normal Applicable To Yes Yes Not Allowed ϬNancial Terms Quoted In Relevant All Bidders Columns Of ϬNancial Bid Will Only Be Ruling Terms For Acceptance, And Such Terms Quoted Anywhere Else Should Be Ignored. Page 6 Of 13 Run Date/Time: 21/03/2025 12:41:51Stores/Southern Rly Tender Document Tender No 16245016 Closing Date/Time 26/05/2025 14:30 4 Whenever Tender Is Ϭ‚Oated With Purchase Normal Applicable To Yes Yes Not Allowed Restriction From Sources Approved By All Bidders Nominated Authorities And There Exists A Suspected Cartel Situation By Approved Sources Or The Rates Available From Approved Source/Sources Are Adjudged Unreasonably High, Despite Fair EffOrts As Permissible, The Purchaser Reserves The Right To Place Orders On ϬRm(S) Outside The Approved Vendor List, Without Any Restrictions.(Please Refer Para 4.0 Of Part B Of Sr Tender Conditions Document Attached To This Tender Document For Further Details.) 5 Hsn Code 8458 Normal Applicable To Yes Yes Not Allowed [A] All The Bidders/Tenderers Should Ensure All Bidders That They Are Gst Compliant And Their Quoted Tax Structure/Rates Are As Per The Gst Law. Firms Must Indicate Its Gst Registration Number Along With Their Offer. [B] In Case The Successful Tenderer Is Not Liable To Be Registered Under Cgst/Igst /Utgst/Sgst Act, The Railway Shall Deduct The Applicable Gst From His/Their Bills Under Reverse Charge Mechanism (Rcm) And Deposit The Same To The Concerned Tax Authority. [C] The ϬRm Should Indicate The Tariff Code (Hsn Code) For Claiming Gst For The Tendered Item. [D] The OffEr Shall Be Evaluated Based On The Gst Rate As Quoted By Each Bidder And Same Will Be Used For Determining The Inter-Se Ranking. While Submitting OffEr, It Shall Be The Responsibility Of The Bidder To Ensure That They Quote Correct Gst Rate And Hsn Number. [E] It Shall Be The Responsibility Of The Bidders To Quote Correct Hsn Number And Corresponding Gst Rate. The Purchaser Shall Not Be Responsible For Any Misclassiï¬Cation Of Hsn Number Or Incorrect Gst Rate, If Quoted By The Bidder. [F] Wherever, The Successful Bidder Invoices The Goods At Gst Rate Or Hsn Number Which Is DiffErent From That Incorporated In The Purchase Order, Payment Shall Be Made As Per Gst Rate Which Is Lower Of The Gst Rate Incorporated In The Purchase Order Or Billed. [G] Vendor Is Informed That She/He Would Be Required To Adjust Her/His Basic Price To The Extent Required By Higher Tax Bill As Per Invoice To Match The All Inclusive Price As Mentioned In The Purchase Order. [H] Any Amendment To Gst Rate Or Hsn Number In The Contract Shall Be As Per The Contractual Conditions And Statutory Amendments In The Quoted Gst Rate And Hsn Number, Under Svc. 6 Please Refer Para 15.0 Of Part - B Of Sr Normal Applicable To Yes Yes Not Allowed Tender Conditions Attached With This All Bidders Tender Document For Details Regarding Benefits Of Mse As Per Public Procurement Policy. 7 For Public Procurement (Preference To Normal Applicable To Yes Yes Not Allowed Make In India) Policy, Please Refer Para All Bidders 16.0 Of Part- B Of Sr Tender Conditions Attached To This Tender Document. Page 7 Of 13 Run Date/Time: 21/03/2025 12:41:51Stores/Southern Rly Tender Document Tender No 16245016 Closing Date/Time 26/05/2025 14:30 8 Bidder Shall Accept The Following Normal Applicable To Yes Yes Allowed Declaration [Land Border Condition] By All Bidders (Mandatory) Quoting Yes Against Conf. Allowed Or Complied Column For Compliance Of Oï¬Ƒce Memorandum Of Department Of Expenditure, Ministry Of Finance Om No. F.No.6/18/2019-Ppd Dated 23.07.2020. If Such Certiï¬Cate Given By A Bidder Whose Bid Is Accepted Is Found To Be False, This Would Be A Ground For Immediate Termination And Further Legal Action In Accordance With Law. I/We Have Read The Clause Regarding Restrictions On Procurement From A Bidder Of A Country Which Shares A Land Border With India. I/We Certify That This Bidder Is Not From Such A Country Or , If From Such A Country, Has Been Registered With The Competent Authority. I/We Hereby Certify That This Bidder, Fulfills All Requirements In This Regard, And Is Eligible To Be Considered. (Where Applicable, Evidence Of Valid Registration By The Competent Authority Shall Be Attached.) 9 1) Bidders Are Instructed Not To Indulge In Normal Applicable To Yes Yes Not Allowed Any Anti-Competitive Practices. As Per The All Bidders Provisions Of Competition Act,2002, Railways Can Make A Reference To The Competition Commission Of India For Making An Enquiry In Case Of Suspected Anti-Competitive Behavior By The Bidders. 2) Collusive Bidding, Bid Rotation, Bid Suppression, Complementary Bidding, Market Allocation And Sub-Contracting Arrangements Fall Under The Purview Of Bid Rigging Which Would Cause Appreciable Adverse EffEct On Competition. 3) Competition Commission Of India Can Impose Heavy Penalties Such As: Penalty Upto 10% Of The Average Turnover For The Last Three Preceding ϬNancial Years Upon Each Of Such Enterprises Which Are Parties To Bid-Rigging And Can Even Order The Parties To Cease And Desist. 10 A) For : Destination. By Road. Normal Applicable To Yes Yes Not Allowed Accordingly, The ϬRms Are Advised To All Bidders Quote On For Destination Basis By Road And Offers With Deviations Are Liable To Be Ignored. B) Door Delivery Shall Be Made To The Consignees Along With Delivery Challan Postal Address Of The Consignees Is: Senior Section Engineer, Electrical Loco Shed, Near Kollampalayam, Erode - 698002, Tamil Nadu, India. Southern Railway Gst No. 33Aaagm0289c1zq. Page 8 Of 13 Run Date/Time: 21/03/2025 12:41:51Stores/Southern Rly Tender Document Tender No 16245016 Closing Date/Time 26/05/2025 14:30 11 Failure Consequences: In Case The ϬRm Normal Applicable To Yes Yes Not Allowed Fails To Execute The Contract Within The All Bidders Original Delivery Period, The Purchaser Will Be Entitled To Impose Liquidated Damages For Extension Of Delivery Period. For Any Reason, If The Supplier Fails To Supply Goods And/Or Service As Per The Conditions Of Contract, As Amended From Time To Time, Purchaser Shall Have The Right To Levy Damages From The Supplier For Failing To Comply With The Contractual Conditions, Not By The Way Of Penalty, An Amount Equal To Security Deposit Of The Defaulted Order Amount. These Damages Shall Be Treated As Recoveries Outstanding Against The Vendor And Dealt With Accordingly. 12 Tenderers To Acknowledge Having Read Normal Applicable To Yes Yes Not Allowed And Also Accept The Irs Conditions Of All Bidders Contract, Sr Tender Conditions, Special And Other Conditions Speciï¬Ed In This Tender Document/Attached To This Tender Document. Page 9 Of 13 Run Date/Time: 21/03/2025 12:41:51Stores/Southern Rly Tender Document Tender No 16245016 Closing Date/Time 26/05/2025 14:30 13 Security Deposit Shall Be Taken From All Normal Applicable To Yes Yes Not Allowed Vendors For Contract Value Above Rs.25 All Bidders Lakhs. Security Deposit Is 5% Of Total Value Of Contract Subject To Max Rs. 50 Lakhs For Contract Value Above 25 Lakhs And Up To Rs.50 Crore. Subject To The Applicable Exemptions. Security Deposit From Successful Tenderers Should Be Received In Purchase Oï¬Ƒce Within 21 Days From The Date Of Communication Of Acceptance With Respect To The Purchaser. There Shall Be No Exemption From Submission Of Security Deposit For Any Tender Or By Any Tenderer Except Following: A) The Store Contract Cases Of Value Upto Rs.25 (Twenty Five) Lakh, B) Other Railways And Government Departments In Terms Of Railway Boards Letter No. 2004/Rs(G)/779/11 Dated 24.07.2007 C) Indian Ordinance Factories In Terms Of Railway Boards Letter No.92/Rss(G)/363/1 Dated 08.04.1993 D) Psus Owned By Ministry Of Railways And Psus For The Group Of Items That Are Manufactured By Them In Terms Of Railway Boards Letter No.2003/Rs(G)/779/5 Dated 10.09.2004 E) In Tenders Issued Against Pac, Oem In Whose Favour Pac Has Been Issued Shall Be Exempted From Submitting Sd. Kvic And Acash Shall Be Exempted From Sd For Items Supplied By Them. F) Vendors Registered With Railways For The Trade Group Of The Item Tendered Shall Be Exempted From Sd For Orders Valued Up To Their Monetary Limit Of Registration. G) Vendors Appearing On The Approved Vendor Lists Of Rdso/Pus/Core Subject To Approval Status Being Valid On The Date Of Tender Closing H) Vendors Registered With Railway For Supply Of Medicine, Medical Equipments And Consumables Shall Be Exempted From Submission Of Sd For These Items. (Please Refer Para 10.0 Of Part A Of Sr Tender Conditions Enclosed To This Tender Document For Further Details On This Clause). Page 10 Of 13 Run Date/Time: 21/03/2025 12:41:51Stores/Southern Rly Tender Document Tender No 16245016 Closing Date/Time 26/05/2025 14:30 14 (A) Free Delivery To Consignee. Supply Of Normal Applicable To Yes Yes Not Allowed Machine Shall Be Made As Per The All Bidders Milestone Chart Given In Sl .No.7 (Delivery Schedule Chart) Of Technical Speciï¬Cation Enclosed. (B) Bill Payment: After Successful Completion Of Purchase Order, ϬRm Has To Submit The Bill On-Line Through Ireps Portal Only For Payment. In This Regard, The Following Documents Have To Be Uploaded Based On The Crn (R-Note) Issued By Railway (A) Invoice, Gst Declaration( I.E. Self Declaration Regarding Aggregate Annual Turnover In A ϬNancial Year: Less (Or) More Than 50 Crores / Less(Or) More Than 100 Crores/Less (Or) More Than 500 Crores. If More Than 500 Crores, E-Invoice Is Required To Be Uploaded.), Rnote, Neft Mandatory. (B) Warranty/Guarantee Certiï¬Cate, Rites Certiï¬Cate, Test Report, Dealership Certiï¬Cate (Or) Proof Of Purchase From Authorized Dealer, Calibration Certiï¬Cate, Commissioning Report Whichever Is Applicable. 15 Packing Instructions: Use Re-Usable Steel Normal Applicable To Yes Yes Not Allowed Cage (Or) Wooden Box (Or) Gunny Bags All Bidders (Jute Bags) (Or) Carton Box (Or) Polythene Bags>50 Micron Only And Use Railway Parcel Transportation. Please Refer Para 1400 Of Section I Of Bid Document Part I. 16 Please Enter The Percentage Of Local Normal Applicable To No Yes Allowed Content In The Material Being OffEred. All Bidders (Optional) Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. The Deï¬Nition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. General Instructions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Railway Is Not Bound To Accept The Lowest Normal Applicable To No No Not Allowed Or Any Tender Or To Assign Any Reason For All Bidders Doing So And Railway Reserves The Right To Accept/Cancel Any Tender In Respect Of The Whole Or Any Portion Of The Items Specified In The Schedule Annexed (Or Tender Schedule) And The Contractor Shall Be Required To Supply The Same At The Rate Quoted. 2 1. For Any Queries Against This Tender, Normal Applicable To No No Not Allowed Please Contact Cmm/M/Sr At 9003060762. All Bidders 2. Any Technical Clariï¬Cation Regarding Drawing/Speciï¬Cation Can Be Obtained From The Oï¬Ƒce Of The Pcee/Sr/Mas. Dy.Cee/Loco Mobile No. 9003160306 And Mail Id [email protected]. Drawing (S) / Speciï¬Cation (S) Can Also Be Obtained From The Above Oï¬Ƒce After Payment Requisite Cost. 3 Vendors May Please Note That Giving Normal Applicable To No No Not Allowed Intimation Regarding The Tender In Open All Bidders Tender Cases Or Giving Limited Tender Enquiry Does Not Guarantee The Suitability Of OffEr For Placement Of Purchase Order. Railway Reserves The Right To Place Purchase Order Subject To Fulï¬Lment Of Technical/Commercial Eligibility Conditions/Tender Conditions. Page 11 Of 13 Run Date/Time: 21/03/2025 12:41:51Stores/Southern Rly Tender Document Tender No 16245016 Closing Date/Time 26/05/2025 14:30 4 All Other Terms & Conditions As Per Irs Normal Applicable To No No Not Allowed Condition And Gcc All Bidders Other Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 A) Inspection By Tpi (Third Party Normal Applicable To No No Not Allowed Inspection Agency). Firm To Indicate All Bidders Complete Works Address Where Inspection Will Be Conducted. The Tenderer Shall Refer Annexure 13 Of Sr Tender Conditions For Further Details Regarding Tpi Clause. Please Note That OffErs With Inspection/Visual Inspection By Tpi Against Test Certiï¬Cate/Guarantee Certiï¬Cate /Work Test Certiï¬Cate Is Liable To Be Ignored. For Further Details Regarding Tpi Clause, The Tenderer Shall Refer Annexure 13 Of Sr Tender Conditions Attached To This Tender Document. Alternatively, Tenderers May Please Refer The Attachment Tpi Conditions Enclosed To This Tender Document For Ready Reference Of Bidders Regarding Tpi Clause. B) Bidder Shall Indicate Place Of Inspection For Pre-Dispatch Inspection Duly Enclosing The Documentary Evidence. Note:- Any Request For Change In Place Of Inspection Shall Only Be Entertained With Documentary Evidence. 2 No. Of Stages Of Inspection: 3; Description Normal Applicable To No No Not Allowed Of Stage-1 Inspection: Raw Material All Bidders Inspection As Per Tender Schedule (As 100% Of Po Qty.), Description Of Stage-2 Inspection: Manufacturing And Fabrication Inspection As Per Tender Schedule (As 100% Of Po Qty.), Description Of Stage-3 Inspection: Final Product Inspection At Firms Premises As Per Tender Schedule (As 100% Of Po Qty.), Description Of 3 Marking : Manufacturer To Mark His Normal Applicable To Yes Yes Not Allowed Name And Month & Year Of Manufacture All Bidders As Per Drawing, Wherever Indicated, Or At A Location Where It May Not Get Obliterated In Service On The Item Being Supplied By Them Against The Purchase Order. Supplies Received Without This Are Liable To Be Rejected By Consignee. 4 I/We Agree To Supply The Tendered Stores Normal Applicable To Yes Yes Not Allowed At The Rates Quoted By Me/Us In All Bidders Accordance With The Irs Conditions Of Contract, Sr Tender Conditions, Special And Other Conditions Speciï¬Ed In This Tender Document/ Attached With This Tender Document. 5 Machine Should Have Warranty Of 24 Normal Applicable To Yes Yes Not Allowed Months From Date Of Successful All Bidders Commissioning. 6 No Developmental Order Will Be Placed For Normal Applicable To Yes Yes Not Allowed The Tendered Item. All Bidders 7 Post Warranty Camc Will Be Concluded By Normal Applicable To Yes Yes Not Allowed End-User Consignee At Their End After All Bidders Warranty Period, If Required. Special Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading Page 12 Of 13 Run Date/Time: 21/03/2025 12:41:51Stores/Southern Rly Tender Document Tender No 16245016 Closing Date/Time 26/05/2025 14:30 1 Insurance Charges Should Be Quoted In Normal Applicable To No No Not Allowed Other Charges Column Against The All Bidders Particular Items. No Separate Line Has Been Provided For Insurance Charges. Technical-Compliances S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Bidders Must Submit Their Technical Bids Normal Applicable To Yes Yes Allowed As Per Format Annexure A. Tenderers Are All Bidders (Mandatory) Required To Submit Complete Details Including Values, Write-Up, Drawings, Sketch, Brochure Etc. As Per Requirement Speciï¬Ed In Respective Clauses Mentioned Therein. In Case Of Incomplete / Sketchy Information, The Technical OffEr Being Incomplete Is Liable To Be Rejected. Tenderers Should Clearly Indicate Compliance. 6. Documents Attached With Tender S.No. Document Name Document Description 1 5215568.Pdf Irs Conditions 2 5215599.Pdf Sr Tender Conditions 3 5322683.Pdf Eligibility Criteria 4 5322647.Pdf Specification For Hydraulic Wheel Press Cap 500 T_ 5 5331382.Pdf 388_Drawing.Pdf 6 5215653.Pdf Guideline On Third Party Inspection 7. Responsiveness S.No. Description 1 Validity Of Offer:-120 Days, No Deviation From The Offer Validity Period Stipulated In The Tender Is Permitted. I/We Have Carefully Gone Through The Irs Conditions Of Contract (Included And Uploaded Along With The Bid Document) Particularly Para 2500 Pertaining To Code Of Integrity, Misdemeanor And Penalties. I/We Hereby Certify That No Other Sister Concerns Or Aï¬Ƒliates (Such As Having Common Partner/Director/Promoter/Owner/Holding Company Decision Control Etc.) Have Participated In This Tender Which Can Give Rise To A ConflIct Of Interest Or Fall Under Anti-Competitive Practices. We Understand That The 2 OffErs Of All Such Sister Concerns Including Ours Are Liable To Be Rejected As Per Relevant Provisions Of Irs Terms And Conditions. I/We, Aï¬Ƒrm That We Shall Abide By The Code Of Integrity In General, With Speciï¬C Reference To ConflIct Of Interest [Para 2502 (E)], Anti Competitive Practices [Para 2502(C)] And Obligation To Proactive Disclosures [Para 2503]. I/We Understand That We Are Fully Responsible For The Above Declaration And It Shall Not Be The Railways Responsibility To Verify The Same. I/We Are Aware That We Shall Be Liable For All Consequences Of Violation Of Code Of Integrity, If Detected, At Any Stage. The Tenderers In Their Bid Shall Indicate The Details Of Their Gst Jurisdictional Assessing Officers (Designation, Address & Email Id). In Case Of A Contract Award, A Copy Of Purchase Order Shall Be Immediately Forwarded By Purchaser To The Gst Jurisdictional Assessing Officer Mentioned In Tenderers Bid This Tender Complies With Public Procurement Policy (Make In India) Order 2017, Dated 15/06/2017, Issued By Department Of Industrial Promotion And Policy, Ministry Of Commerce, Circulated Vide Railway Board Letter No. 2015/Rs(G)/779/5 Dated 03/08/2017 And 27/12/2017 And Amendments/ Revisions Thereof. As A Tender Inviting Authority, The Undersigned Has Ensured That The Issue Of This Tender Does Not Violate Provisions Of Gfr Regarding Procurement Through Gem. Digitally Signed By Cmm/M ( Baba Tulajaram Lalge ) , Cost Of Optional Accessories With Breakup Of Individual Items ] , Cost Of Spares Required For Two Years Period Of Warranty. ] , Turnkey Charges Namely Foundation, Installation And Commissioning Of Hydraulic Wheel Press 500 T Capacity. ] At (Location) Sr.Dee/Rs/Els/Ed, Sr Tamil Nadu 1.00 Numbers 8 6579Ser2 Essential Non Stock --- Yes Consignee Inr (G1) Services (Y) Cost Of Preventive Maintenance During 1St And 2Nd Years Of Warranty Period As Per Clause 2 3.3. ] At (Location) Sr.Dee/Rs/Els/Ed, Sr Tamil Nadu 1.00 Numbers 3. T And C F.O.R Description Destination Delivery Period Description Delivery /Completion Rate Of Supply For All Items Commencement : Within 4 Months Of Issue Of Contract, However, Delivery Completion : Within 6 Months Thereafter Period Shall Not Exceed No. Of Days As Mentioned In Delivery Schedule Chart Of Para 7 Of Section Iv Of Bid Document Part Ii. However, The Delivery Period Indicated Being Tentative, May Vary At The The Time Of Placement Of Order. Payment Terms S.No Description Payment Terms 1 1) 60% Payment: Upon Receipt Of The M&P (Includes Covered Shed, Linkage Of Track, Inside Shed, Outside Shed, Power Supply Connection, Provision Of Toilets With Urinal Facility Along With Septic Tanks), Duly Pre- Inspected By A Third -Party Inspection (Tpi) Agency, Receipted At The Site By The Consignee In Good Condition And Submission Of A Joint Receipt Note. 2) 20% Intermediate Payment: After Successful Installation And Commissioning And Submission Of A Joint Commissioning Note. 3) Final 20% Payment: After Commissioning Of The M&P At The Consignees End For A Minimum Period Of 30 Days, Upon Submission Of A 10% Warranty Bank Guarantee And A Proving Test Certificate Statutory Variation Clause Page 2 Of 13 Run Date/Time: 21/03/2025 12:41:51Stores/Southern Rly , Cost Of Preventive Maintenance During 1St And 2Nd Years Of Warranty Period As Per Clause 2 ] At (Location) Sr.Dee/Rs/Els/Ed, Sr Tamil Nadu 1.00 Numbers
Contract Date: Mar 16, 2026 Contract Value : 2.31 Crore
Government Departments No of Bidders 1
43.
Educational and Research Institute #9788745 Technical Bid
Supply Of Printed Books As Per Tender Document , Printed Books : , Fundamentals Of Chemistry, Quantitative Analysis, 1Stedition/R. L. Madan/S. Chand/9355011628/English , Principles Of Physical Chemistry, 49Th Edition/Puri, Sharma, Pathania/Vishal Publication Co./9382956018/English , General And Inorganic Chemistry,Vol 1, 3Rd Edition/R. P. Sarkar/New Central Book Agency/8173816808/English , General And Inorganic Chemistry,Vol 2, 3Rd Edition/R. P. Sarkar/New Central Book Agency/8173817278/English , Modern Inorganic Chemistry/R. N. Madan/S. Chand/8121900743/English , The World Of Physical Chemistry/Keijth J. Laidler/Oup Oxford/978-8123906454/English , States Of Matter And Ions In Solution, 6Th Ed.,Vol1/K. L. Kapoor/Mcgraw Hill Education/9353165180/English , A Textbook Of Physical Chemistry, Thermo-Dynamics And Chemical Equilibrium (Si Units) - Vol. 2 | 6Th Edition/K. L. Kapoor/Mcgraw Hill Education/9353165202/English , A Textbook Of Physical Chemistry - Application Of Thermodynamics | Volume 3, 5Th Edition/K. L. Kapoor/Mcgraw Hill Education/9389811309/English , A Textbook Of Physical Chemistry - Quantum Chemistry And Molecular Spectroscopy | Volume 4, 6Th Edition/K. L. Kapoor/Mcgraw Hill Education/9389811317/English , A Textbook Of Physical Chemistry - Dynamics Of Chemical Reactions, Statistical Thermodynamics, Macromolecules And Irreversible Processes/K. L. Kapoor/Mcgraw Hill Education/9389811325/English , A Textbook Of Physical Chemistry, Computational Aspects In Physical Chemistry (Si Units)Volume 6, 4/E/K. L. Kapoor/Mcgraw Hill Education/9353165210/English , A Textbook Of Physical Chemistry: Experimental Aspects In Physical Chemistry (Si Units) Vol- 7/K. L. Kapoor/Mcgraw Hill Education/9353165482/English , Fundamental Concepts Of Inorganic Chemistry , Volume 1, 3Rd Ed/Asim K Das And Mahua Das/Cbs/9389565979/English , Fundamental Concepts Of Inorganic Chemistry Vol 2, 3Rd Edition/Asim K Das/Cbs/9389688027/English , Fundamental Concepts Of Inorganic Chemistry Vol 3A 3Ed/Asim K Das/Cbs/9390709113/English , Fundamental Concepts Of Inorganic Chemistry Vol 3B 3Ed/Asim K Das/Cbs/9390709121/English , Fundamental Concepts Of Inorganic Chemistry, Volume 4, Including Coordination Chemistry - 2/E/Asim .K Das/Cbs/9354661890/English , Fundamental Concepts Of Inorganic Chemistry: Volume 4/Asim K Das And Mahua Das/Cbs/8123923512/English , Fundamental Concepts Of Inorganic Chemistry Vol 5/Asim K. Das And Mahua Das/Cbs/8123923529/English , Fundamental Concepts Of Inorganic Chemistry, Vol.6/Asim K. Das And Mahua Das/Cbs/8123923536/English , Organic Chemistry Vol. 1/S.M.Mukharji, S.P.Singh, R.P. Kapoor/New Age Publishers/8122427383/English , Organic Chemistry Vol. 2/S.M.Mukharji, S.P.Singh, R.P. Kapoor/New Age Publishers/8122433685/English , Organic Chemistry Vol. 3/S.M.Mukharji, S.P.Singh, R.P. Kapoor/New Age Publishers/8122436110/English , Advanced Organic Chemistry/Jagdamba Singh, L.D.S. Yadav, Jaya Singh/Pragati Publisher/978-9385904363/English , Introduction To Spectroscopy, 5Th Edition/Pavia, Lampman, Kriz, Vyvyan/Cengage India Private Limited/9381466475/English , Advanced Practical Chemistry/Subhas C Das/The World Press Private Limited/8190194402/English , Organic Chemistry, 2E/Jonathan Clayden/Oxford University Press/978-0198728719/English , A Guidebook To Mechanism In Organic Chemistry, 6E/Peter Sykes/Pearson Education/8177584332/English , Organic Chemistry/Subrata Sengupta/Oxford University Press/978-0199451647/English , Advanced Organic Reaction Mechanism/N Tewari/Books & Allied/8187134565/English , Organic Reactions And Their Mechanisms/P.S. Kalsi/New Age International Private Limited/9389802083/English , Spectroscopy Of Organic Compounds/P.S. Kalsi/New Age International Private Limited/8122440638/English , Organic Chemistry, Vol. 1, 6E/I. L. Finar/Pearson Education India/8177585428/English , Organic Chemistry Vol 2/I. L. Finar/Pearson Education India/8177585414/English , Problem And Solutions In Organic Chemistry/I. L. Finar/Pearson Education India/8131700938/English , Principles Of Inorganic Chemistry/Puri Sharma Kalia/Vishal Publishing Co./8192143333/English , Coordination Chemistry - Sixth Edition/Ajai Kumar/Aaryush Education/8193043707/English , Concise Inorganic Chemistry, 5/E/J. D. Lee/Oxford University Press/8126515546/English , Inorganic Chemistry/Catherine Housecroft/Pearson/978-1292134147/English , Organic Chemistry: Aspect And Causal Structure/Jonathan Clayden/Oxford/978-0199270293/English , Practical Organic Chemistry/Frederick George Mann And B Charles Saunders/Pearson Education India/8131727102/English , Advanced Practical Organic Chemistry - 3Rd Edn/N K Vishnoi/S Chand/8125931287/English , Organic Reaction Mechanisms, Selected Problems, And Solutions/William C. Groutas/Crc Press/978-1032488257/English , Advanced Practical Inorganic Chemistry/Gurdeep Raj/Krishna Prakashan Media (P) Ltd/8185842833/English , Fundamental Concepts Of Inorganic Chemistry Vol 7/Asim K. Das And Mahua Das/Cbs/8123923543/English , Introduction To Electro- Dynamics/David J. Griffiths/Pearson Education India Learning Pvt.Ltd/978-9332550445/English , Principles Of Optics/Max Born & Emil Wolf/Cambridge University Press/978-0521639217/English , Optics/Ajoy K Ghatak/Mcgraw Hill/978-9355328595/English , Optics/Eugene Hecht & A.R. Ganesan/Pearson Education/978-9353439590/English , Fundamentals Of Optics (Indian Edition)/Jenkins And White/Mcgraw Hill Inc., Us/978-0070323285/English , Thermo-Dynamics Kinetic Theory And Statistical Thermodynamics/Sears Salinger/Narosa Publishing House/978-8185015712/English , University Physics With Modern Physics, 15E/Hugh D. Young And Roger A. Freedman/Pearsoneducation/978-9353949297/English , Heat And Thermo- Dynamics/Mark W. Zemansky/Mcgraw Hill Inc., Us/978-0070700352/English , Thermal Physics Kinetic Theory Thermodynamics And Statistical Mechanics/S.C. Garg, R.M. Bansal And C.K. Ghosh/Mcgraw Hill/978-1259003356/English , Thermodynamics/Enrico Fermi/Dover Publication Inc./978-0486603612/English , Statistical Mechanics, 4Th Edition/R.K. Pathria And Paul D. Beale/Academic Press/978-0081026922/English , Fundamentals Of Statistical And Thermal Physics/F. Reif/Levant Books/978-9380663142/English , Statistical Mechanics, 2Ed/K. Huang/Wiley/978-8126518494/English , Quantum Mechanics/L.I. Schiff/Mcgraw Hill Education/978-1259062865/English , Quantum Physics, 3Ed/S. Gasiorowicz/Wiley/978-8126511174/English , Quantum Mechanics/B. Craseman/Dover Publications/978-0486794594/English , Quantum Mechanics/Albert Messiah/Dover Publications Inc./978-0486784557/English , Modern Quantum Mechanics/J J Sakurai And Jim Napolitano/Cambridge University Press/978-1108473224/English , A Textbook Of Quantum Mechanics/Mathews And Venkatesan/Mcgraw-Hill Education / India/978-0070965102/English , Introduction To Quantum Mechanics, 3Rd Edition/David J Griffiths/Cambridge University Press/978-1108791106/English , Millmans Integrated Electronics,2Nd Edition/Jacob Millman, Christos Halkias And Chetan D Parikh/Mcgraw Hill Education/978-0070151420/English , Electronic Principles (Sie) | 7Th Edition/Albert Malvino/Mcgraw Hill Education/978-0070634244/English , Electronic Fundamentals And Applications: Integrated And Discrete Systems/John D. Ryder/Prentice Hall India Learning Private Limited/978-8120300828/English , Op-Amps And Linear Integrated Circuits/Ramakant A. Gayakwad/Pearson Publication/978- 8120320581/English , Electronics Fundamentals And Applications/D Chattopadhyay And P C Rakshit/New Age International Private Limited/978-9387788633/English , Electronic Devices And Circuit Theory 11Th Edition/R L Boyelstad/Pearson Education India/978- 9332542600/English , Fundamentals Of Digital Circuits/A Anand Kumar/Phi/978-8120352681/English , Modern Digital Electronics | Fourth Edition/R P Jain/Mcgraw Hill Education/978-0070669116/English , Digital Fundamentals, 11Th Edition/Thomas L Floyd/Pearson Education India/978-9332584600/English , Physics Of Atoms And Molecules, 2Nd Edition/B H Bransden And C J Joachain/Pearson/978-8177582796/English , Introduction To Atomic Spectra/H. E. White/Mcgrawhill Exclusive (Cbs)/978-9352604777/English , Atomic And Molecular Physics/Raj Kumar/Campus Books International/978-8180300356/English , Atomic Physics (Modern Physics)/Dr. Sn Ghoshal/S Chand & Company/978-8121910958/English , Nuclear Physics/Dr. Sn Ghoshal/S Chand & Company/978-9352837274/English , Nuclear Physics: Theory And Experiments/R R Roy And B P Nigam/New Age International Pvt Ltd/978-8122434101/English , Introductory Nuclear Physics/K S Krane/Wiley/978-8126517855/English , Nuclear Physics/D C Tayal/Himalaya Publishing House/978-9350978306/English , Mathematical Physics , 6Th Edition/H. K. Dass & Dr. Rama Verma/S. Chand/8121914698/English , Mathematical Physics ,4Th Edition/B. D. Gupta/Vikas Publishing House/978-9354535062/English , Classical Mechanics/Herbert Goldstein/Pearson/978-8131758915/English , Electromagnetic Theory & Electrodynamics/Satya Prakash/Kedar Nath & Ram Nath/978-8190621696/English , Electromagnetic Field Theory/S.K. Gupta/Krishan Prakashan/978-6200782281/English , Advanced Engineering Mathematics./Jain And Iyengar/Alpha Science International Ltd/8184875606/English , An Introduction To Analysis:Differential Calculus./R. K. Ghosh&K. C. Maity/New Central Book Agency/8173814376/English , Vector Analysis./Maity And Ghosh/New Central Book Agency/817381113X/English , Advanced Higher Algebra/Ghosh And Chakraborty/U. N, Dhur/9380673671/English , Complex Variables:Theory And Applications./H. S. Kasana/Prentice Hall India/8120326415/English , Thomas’S Calculus/Thomas And Finney/Pearson Publishers/134438981/English , Linear Algebra Done Right, 2Nd Edn/Axler/Springer International Student Edition/978-0387982588/English , Linear Algebra, 2Nd Edn/Hoffman, K., Kunze/Prentice Hall Int. Inc., Englewood Cliffs/978-0135367971/English , Ordinary And Partial Differential Equation/M.D. Raisinghania/S. Chand/978-9352837305/English , An Introduction To Ordinary Differential Equations/E. A. Coddington/Prentice Hall India/978-8120305479/English , Partial Differential Equations/L. C. Evans/The Orient Blackswan/978-1470414979/English , Introduction To Real Analysis/S.K. Mapa/Sarat Impressions Pvt. Ltd/978-9382124318/English , Introduction To Complex Analysis/H. A. Priestly/Clarendon Press, Oxford/978-0198525622/English , Computer Programming In C/V. Rajaraman/Prentice Hall, India/978-8120353302/English , Basic Computation And Programming With C/Subrata Saha, Subhodip Mukherjee/Cambridge University Press/978-1109468077/English , Introductory Methods Of Numerical Analysis/S. S. Sastry/Phi/978-8120345925/English , An Introduction To Numerical Analysis (Indian Edition)/Kendall E. Atkinson/Wiley India Private Limited/978-8126518500/English , Linear Programming And Game Theory/J. G. Chakravorty And P. R. Ghosh/Mouli K Library/B08sk4sdpr/English , Mathematical Programming Techniques/Kambo/East-West Publi./978-8185336473/English , Operations Research/S. D. Sharma/Kedarnath/978-8190701105/English , Numerical Methods And Computer Programming/Anju Khandelwal/Narosa/978-8184874157/English , C Language And Numerical Methods/C. Xavier/New Age Int. Publishers/978-8122411741/English , Introduction To Mathematical Statistics/Robert V. Hogg, Joseph W. Mckean/Pearson Education/978-0321795434/English , Statistical Methods—Combined Edition (Vol. I & Ii)/N.G. Das/Mc. Graw Hill Education/978-9352605225/English , Co-Ordinate Geometry (2-D And 3-D)/Ajay Kumar, Ravi Prakash, Usha Gupta/Mcgrawhilleducation/978-9352602019/English , Golden Co-Ordinate Geometry/N.P. Bali/Laxmi Publications/978-8131803803/English , Engineering Mechanics, Statics And Dynamics/Rao/Pearson Education/978-8131718663/English , Elements Of Statics & Dynamics/Loney, S. L/Maxford Books/978-8183410078/English , Cryptography, Theory & Practice/Douglas R. Stinson/Crc Press/978-1138451090/English , Introduction To Algebraic Number Theory/Saban Alaca, Kenneth S Williams/Cambridge University Press/978-0521540117/English , Elementary Number Theory & Its Applications, At&T Bell Laboratories/Kenneth. H. Rosen/Pearson Education Limited /978-9367130681/English , Ancient Indian Education:Brahmanical & Buddhist/R.K Mookerji/Motilal Banarsidass/978-8120804234/English , Indian Education: An Enquiry Into Its Origin, Development And Ideals/F.E Keay/Forgotten Books/978-1334676208/English , History Of Education Policymaking In India(1947-2016)/R.V Vaidyanatha Iyer/Oup India/978-0199474943/English , Education In India After Independence/Jagdish Chand/Shipra Publication/978-8183641067/English , A Cultural History Of India/A.L. Basham/Oxford University Press/978-0195639216/English , The Wonder That Was India/A.L. Basham/Picader/9389109345/English , Evolution Of Indian Culture- From The Earliest Times To The Present Day/B.N Lunia/Lakshmi Narain Agarwal/B08gsbp74z/English , Advanced Educational Psychology/S.K Mangal/Phi Learning/978-8120320383/English , Theories Of Personality/C.S. Hall,L.Gardner, B.C Jhon/Wiley India Pvt. Ltd/978-8126510924/English , Child Growth And Development/E.B Hurlock/Kessinger Publishing/978-1163145791/English , Handbook Of The Teaching Of Psychology/W. Buskist, S.F Davis (Eds)/Blackwell Publication/978-1405138017/English , Cognitive Psychology Mind And Brain/E.E Smith, S.M Kosslyn/Pearson Education India/978-9332550452/English , Developmental Psychology: A Lifespan Approach/E.B Hurlock/Mcgraw -Hill/978-0070993631/English , Educational Psychology/A Woolfolk/Pearson Publication/978-9332586697/English , Becoming Critical Teacher Educatore: Narratives Of Disruption/Julie Ellison Justic,F.Blake Tenore/Routledge/978-1138225145/English , The Oxford Handbook Of Philosophy Of Education/H. Siegal/Oxford University Press/978-0199915729/English , Education In Emerging Indian Society/A.S Thakur, S. Berwal/Mayur Paperbacks/978-8171981786/English , Sociology Basic Concepts/H.K. Rawat/Rawat Publication/978-8131600559/English , Sociology:Principles Of Sociology With An Introduction To Social Thoughts/C.N.S Rao(Eds)/S.Chand & Company Pvt. Ltd/B08ykfnrvm/English , Cyber Law: Maximising Safety And Minimizing Risk In Classrooms/A.M. Bissonette/Sage Publication India Pvt Ltd/978-1412966153/English , Blended Learning In Action: A Practical Guide Toward Sustainable Change/C.R.Tucker, T. Wycoff, J.T. Green/Corwin/978-1506341163/English , Educational Evaluation: Theory And Practice/R.N Patel/Himalaya Publishing House/978-9350244593/English , Essential Of Examination System: Evaluation,Tests And Measurement/J.C Aggarwal/Vikash Publishing House Pvt. Ltd/8125900519/English , Measurement And Assessment In Teaching/M.David Miller,Robert L.Linn And Norman Gronlund/Pearson/978-8131720752/English , The Journey Of Inclusive Education In The Indian Sub-Continent/M.Alur, M.Bach/Routledge/978-0415988766/English , Inclusive Education:International Policy & Practice/A.C Armstrong, D Armstrong& I Spandagou/Sage Publication/978-1847879417/English , Counselling And Guidance/S Rao/Mcgraw -Hill/978-1259005077/English , Guidance & Counselling For Children And Adolescence In Schools (India)/Namita Ranganathan, Toolika Wadhwa/Sage Publication/9386062917/English , Policy, Practice & Politics In Teacher Education/Marilyn Cochran Smith/Corwin Publication/978-1412928113/English , Pedagogy Of English/M.S Sachdeva/Twenty-First Century Publication/978-9385446689/English , Pedagogy Of Education/Dr. Marami Goswami/Neekamal/978-8170637134/English , Philosophical And Sociological Perspectives Of Education/Prof. Raman Bihari Lal And Suneeta Palod/R.Lall/978-9385282805/English , Learning And Teaching/Dr. Sk Mangal And Dr. (Mrs) Uma Mangal/Phi Learning Pvt. Ltd./978-9388028189/English , The Practice Of English Language Teaching 5Th Edition/Jeremy Harmer/Pearson Longman/978-1447980254/English , Approaches And Methods In Language Teaching/Theodore S. Rodgers And Jack C. Richards/Cambridge University Press (South Africa)/978-1107675964/English , Pedagogy Of Language Teaching/Samir Kumar Mahato, Aabriti Sharma/Rita Publications/978-9382229025/English , Pedagogy Of Mathematics/Madhu Sahni/Vikas Publishing/978-9353383275/English , Pedagogy Of Mathematics/Dr. S. K. Mangal/Tondon Publication/B08pbzyxwf/English , General And Inorganic Chemistry (Vol- 1 & 2)/R. P. Sarkar/New Central Book Agency/978-8173816802/English , The Hundred-Year-Old Man Who Climbed Out Of The Window And Disappeared/Jonas Jonasson/Abacus/978-0349141800/English , When Youre Ready, This Is How You Heal/Brianna Wiest/Amaryllis/978-9355435538/English , The Strength In Our Scars/Bianca Sparacino/Amaryllis/978-9355439291/English , A Gentle Reminder/Bianca Sparacino/Amaryllis (An Imprint Of Manjul Publishing House)/978-9355438485/English , The Four Agreements/Don Miguel Ruiz/Amber-Allen Publishing/978-1878424402/English , The Voice Of Knowledge/Don Miguel Ruiz/Amber-Allen Publishing/978-1878424549/English , No Worries/Bella Mente Press/Bella Mente Press/978-1952676000/English , Data Structures And Algorithms Made Easy/Karumanchi Narasimha/Careermonk Publications/978-8193245279/English , Attitude Is Everything Change Your Attitude Change Your Life/Jeff Keller/Collins/978-9351772071/English , Who Moved My Cheese - An Amazing Way To Deal With Change In Your Work And In Your Life./Dr Spencer Johnson/Ebury Publishing/978-0091816971/English , Little Women/Louisa May Alcott/Fingerprint Publishing/978-9354406300/English , The Law Of Success In Sixteen Lessons/Napoleon Hill/Fingerprint! Publishing/978-9388144346/English , The Power Of Prayer/Dr. Joseph Murphy/Fingerprint! Publishing/978-9389053784/English , The Pursuit Of Happiness/Daniel G. Brinton/Fingerprint! Publishing/978-9388369091/English , A Midsummer Night’S Dream/William Shakespeare/Fingerprint! Publishing/978-8175994508/English , The Inferno/Dante Alighieri/Fingerprint! Publishing/978-8175993884/English , The Complete Novels Of Sherlock Holmes/Arthur Conan Doyle/Fingerprint! Publishing/978-8175994317/English , The Happy Prince And Other Tales/Oscar Wilde/Fingerprint! Publishing/978-9389931006/English , Of Mice And Men/John Steinbeck/Grapevine India/978-9357009522/English , The Slight Edge/Jeff Olson/Greenleaf Book Group Llc/978-1626340466/English , Learning To Silence The Mind: Wellness Through Meditation/Osho/Griffin/978-1250006226/English , All The Light We Cannot See/Anthony Doerr/Harper/978-0008172428/English , Flow: Thepsychology Of Optimal Experience/Mihaly Csikszentmihalyi/Harper Perennial Modern Classics/978-0061339202/English , The Mind-Gut Connection/Emeran Mayer/Harper Wave;/978-0062376589/English , Love Yourself Like Your Life Depends On It/Kamal Ravikant/Harpercollins Publishers/978-0008374709/English , What I Wish I Knew When I Was 2: A Crash Course On Making Your Place In The World/Tina Seeling/Harperone/978-0062047410/English , Almond : A Novel/Won-Pyung Sohn/Harperone/978-0063266919/English , You Can Heal Your Life/Louisa May Alcott/Hay House India/978-8190565585/English , Why Zebras Dont Get Ulcers/Robert M. Sapolsky/Holt Paperbacks/978-0805073690/English , The Psychology Of Money/Morgan Housel/Jaico Publishing House/978-9395970334/English , The 5 Am Club/Robin Sharma/Jaico Publishing House/978-9387944893/English , The Practicing Mind/Thomas M. Sterner/Jaico Publishing House/978-9386867100/English , Who Will Cry When You Die?/Robin Sharma/Jaico Publishing House/978-8179922323/English , The Theory Of Everything/Stephen Hawking/Jaico Publishing House/978-8179925911/English , The Leader Who Had No Title/Robin Sharma/Jaico Publishing House/978-8184951196/English , Chanakya Neeti/Radhakrishnan Pillai/Jaico Publishing House/978-9388423571/English , Brief Answers To The Big Questions:/Stephen Hawking/John Murray/978-8466424578/English , The Miracle Morningthe 6 Habits That Will Transform Your Life Before 8Am/Hal Erold/John Murray One/978-1399816052/English , Dont Believe Everything You Think/Joseph Nguyen/Manjul Publishing House/978-9355431356/English , The Compound Effect/Darren Hardy/Manjul Publishing House/978-9390924639/English , The Art Of Dealing With People/Les Giblin/Manjul Publishing House/978-8183226745/English , The Compound Effect/Darren Hardy/Manjul Publishing House/978-9390924639/English , The Untethered Soul: The Journey Beyond Yourself/Michael A. Singer/New Harbinger/978-1572245372/English , Philip K. Dicks Electric Dreams/Philip K. Dick/Orion Publishing Co/978-1473223288/English , The Hitchhiker’S Guide To The Galaxy/Douglas Adams/Pan/978-1529034523/English , Focus On What Matters/Darius Foroux/Penguin/978-0143461845/English , Why We Sleep/Matthew Walker/Penguin/978-0141983769/English , Energize Your Mind/Gaur Gopal Das/Penguin Ananda/978-0143442288/English , Make Your Bed/Admiral William H. Mcraven/Penguin Books Ltd/978-0718188863/English , Life 3.0: Being Human In The Age Of Artificial Intelligence/Max Tagmark/Penguin Books Ltd/978-0141981802/English , Thinking, Fast And Slow/Kahneman Daniel/Penguin Books Ltd/978-0141033570/English , Start With Why/Sinek Simon/Penguin Books Ltd/978-0241958223/English , Digital Minimalism: Choosing A Focused Life In A Noisy World/Cal Newport/Penguin Business/978-0241737996/English , You Only Live Once/Stuti Changle/Penguin Ebury Press/978-0143453581/English , Do It Today/Darius Forous/Penguin India/978-0265394281/English , Sapiens: A Brief History Of Humankind:/Yuval Noah Harari/Penguin Random House/978-0099590088/English , Three Thousand Stitches/Murty Sudha/Penguin Random House India/978-0143440055/English , Here, There And Everywhere/Murty Sudha/Penguin Random House India/978-0143444343/English , Quiet : The Power Of Introverts In A Wor: The Power Of Introverts In A World That Cant Stop Talking/Susan Cain/Penguin Uk/978-0141029191/English , Blink (L): The Power Of Thinking Without Thinking/Malcolm Gladwell/Penguin Uk/978-0141014593/English , Charisma Myth/Olivia Fox Cabane/Penguin Uk/978-0670922871/English , The Drama Of The Gifted Child/Alice Miller/Perseus Books Group/978-0465016907/English , Before The Coffee Gets Cold*/Toshikazu Kawaguchi/Picador/978-1035035052/English , You Are Born To Blossom/Dr Apj Abdul Kalam/Prabhat Prakashan/978-8184303360/English , The Obstacle Is The Way/Ryan Holiday/Profile Books/978-1781251485/English , Mastery/Robert Greene/Profile Books/978-1781250914/English , The 48 Laws Of Power/Robert Greene/Profile Books/978-1861972781/English , Ego Is The Enemy/Ryan Holiday/Profile Books Ltd/978-1781257012/English , Never Split The Difference/Chris Voss/Random House Business/978-1847941497/English , When Breath Becomes Air/Kalanithi Paul/Random House Usa Inc/978-0812988406/English , Quiet/Cain Susan/Random House Usa Inc/978-0307352156/English , The Wim Hof Method/Wim Hof/Rider/978-1846046308/English , The Art Of Communicating/Thich Nhat Hanh/Rider & Co/978-1846044007/English , Mans Search For Meaning: The Classic Tribute To Hope From The Holocaus/Viktor E. Frankl/Rider & Co/978-1846041242/English , Drive The Surprising Truth About What Motivates Us/Daniel H.Pink/Riverhead Books/978-1594484803/English , Learning How To Fly: Life Lessons For The Youth/A.P.J. Abdul Kalam/Rupa Publications India/978-8129142153/English , The War Of Art: Break Through The Blocks And Win Your Inner Creative Battles/Steven Pressfield/Sanage Publishing House/978-1936891023/English , The Art Of Thinking Clearly/Rolf Dobelli/Sceptre/978-1444759549/English , The Secret/Rhonda Byrne/Simon And Schuster/978-1471172397/English , Memory: How To Develop, Train And Use It/William Walker Atkinson/Srishti Publishers & Distributors/978-9390441020/English , You Can/George Matthew Adams/Srishti Publishers & Distributors/978-9395192460/English , Be Your Own Sunshine: Towards A Better Tomorrow/James Allen/Srishti Publishers & Distributors/978-9387022850/English , When The Body Says No/Dr Gabor Maté/Vermilion/978-1785042225/English , Surrounded By Idiots/Thomas Erikson/Vermilion/978-1785042188/English , Four Thousand Weeks/Oliver Burkeman/Vintage/978-1784704001/English , Homo Deus/Yuval Noah Harari/Vintage/978-1784703936/English , Essentialism: The Disciplined Pursuit Of Less/Greg Mckeown/Virgin Books/978-0753558690/English , What Every Body Is Saying/Marvin Karlins Joe Navarro/William Morrow Paperbacks/978-0063069275/English , Educated/Tara Westover/Windmill Books/978-0099511021/English , Read People Like A Book/Patrick King/Wisdom Tree/978-8183286107/English , Show Your Work!/Austin Kleon/Workman Publishing/978-0761178972/English , Keep Going/Austin Kleon/Workman Publishing/978-1523506644/English , Mans Searching For Meaning/Vickor E.Frankl/Wow Publishing Pvt/978-8184157383/English , The Power Of Now: A Guide To Spiritual Enlightenment/Eckhart Tolle/Yogi Impressions Books Pvt Ltd/978-1444700848/English , Oxford Student Atlas For India/Oxford University Press/Oxford University Press/978-0199470648/English , Oxford Student Atlas/Patrick Wiegand/Oxford University Press/978-0199136988/English , Atomic Habits: An Easy & Proven Way To Build Good Habits & Break Bad Ones/James Clear/Penguin Random House/978-1847941831/English , Ghost Of Fear Streets/R.L. Stine/Aladdin/978-1442486164/English , Andha Yug/Dharamvir Bharati/Oxford University Press/978-0198065227/English , Electric Machines/Ashfaq Hussain/Dhanpat Rai & Co/978-8177001662/English , At The Speed Of Light/G Venkatraman/Universities Press (India)/978-8173710094/English , Quantum Revolution I — The Breakthrough/G Venkatraman/Universities Press (India)/978-8173710025/English , Quantum Revolution Ii — Qed: The Jewel Of Physics/G Venkatraman/Universities Press (India)/978-8173710032/English , Quantum Revolution Iii — What Is Reality?/G Venkatraman/Universities Press (India)/978-8173710049/English , Raman And His Effect/G Venkatraman/Universities Press (India)/978-8173710087/English , Saha And His Formula/G Venkatraman/Universities Press (India)/978-8173710179/English , A Hot Story/G Venkatraman/Universities Press (India)/978-8173710100/English , Why Are Things The Way They Are?/G Venkatraman/Universities Press (India)/978-8173710339/English , The Many Phases Of Matter/G Venkatraman/Universities Press (India)/978-8173710346/English , Bose And His Statistics/G Venkatraman/Universities Press (India)/978-8173710360/English , Chandrasekhar And His Limit/G Venkatraman/Universities Press (India)/978-8173710353/English , Big And The Small, The: Journey Into The Microcosm/G Venkatraman/Universities Press (India)/978-8173712272/English , Big And The Small, The - Vol. Ii : From The Microcosm To The Macrocosm: The Fascinating Link Between Particle Physics And Cosmology/G Venkatraman/Universities Press (India)/978-8173715747/English , Upkar Prakashan Csir - Ugc Net/Jrf/Set Physical Sciences/Surekha Tomar/Upkar Prakashan/B0ckzctk11/English , Death Note Black Edition Vol. 1/Tsugumi Ohba, Takeshi Obata/Viz Media Llc/978-1421539645/English , Attack On Titan Vol. 1/Hajime Isayama/Kodansha Comics/978-1612620244/English , One Piece Omnibus Edition Vol. 1/Eiichiro Oda/Viz Media Llc/978-1421536255/English , Demon Slayer: Kimetsu No Yaiba Vol. 1/Koyoharu Gotouge/Viz Media Llc/978-1974700523/English , Naruto 3-In-1 Edition Vol. 1/Masashi Kishimoto/Viz Media Llc/978-1421539898/English , Your Name. (Light Novel)/Makoto Shinkai/Yen On/978-0316476479/English , Spy X Family Vol. 1/Tatsuya Endo/Viz Media Llc/978-1974715466/English , Chainsaw Man Vol. 1/Tatsuki Fujimoto/Viz Media Llc/978-1974709939/English , 12 Rules For Life: An Antidote To Chaos/Jordan B. Peterson/Penguin Random House/978-0345816023/English , Beyond Order: 12 More Rules For Life/Jordan B. Peterson/Penguin Random House/978-0593084649/English , The Power Of Now/Eckhart Tolle/New World Library/978-1577314806/English , Think Like A Monk/Jay Shetty/Simon & Schuster/978-1982134488/English , Sapiens: A Brief History Of Humankind/Yuval Noah Harari/Harper/978-0062316097/English , Homo Deus: A Brief History Of Tomorrow/Yuval Noah Harari/Harper/978-0062464316/English , 21 Lessons For The 21St Century/Yuval Noah Harari/Spiegel & Grau/978-0525512172/English , Ikigai: The Japanese Secret To A Long And Happy Life/Héctor García, Francesc Miralles/Penguin Random House/978-0143130727/English , The Courage To Be Disliked/Ichiro Kishimi, Fumitake Koga/Allen & Unwin/978-1760630737/English , Flow: The Psychology Of Optimal Experience/Mihaly Csikszentmihalyi/Harper Perennial/978-0061339202/English , The Untethered Soul/Michael A. Singer/New Harbinger Publications/978-1572245372/English , The Subtle Art Of Not Giving A F*Ck/Mark Manson/Harper/978-0062457714/English , Everything Is F*Cked: A Book About Hope/Mark Manson/Harper/978-0062888433/English , Meditations/Marcus Aurelius/Penguin Classics/978-0140449334/English , Bhagavad Gita: As It Is/A.C. Bhaktivedanta Swami Prabhupada/The Bhaktivedanta Book Trust/978-9384564191/English , The Tao Of Physics/Fritjof Capra/Shambhala/978-1570625190/English , The Art Of War/Sun Tzu/Shambhala/978-1590302255/English , A Brief History Of Time/Stephen Hawking/Bantam/978-0553380163/English , Cosmos/Carl Sagan/Ballantine Books/978-0345539434/English , The Brain That Changes Itself/Norman Doidge/Viking/978-0143113102/English , Incognito: The Secret Lives Of The Brain/David Eagleman/Vintage/978-0307389920/English , Thinking, Fast And Slow/Daniel Kahneman/Farrar, Straus And Giroux/978-0374533557/English , Predictably Irrational/Dan Ariely/Harper/978-0061353239/English , The 4-Hour Workweek/Timothy Ferriss/Crown Publishing/978-0307465358/English , Rich Dad Poor Dad/Robert T. Kiyosaki/Plata Publishing/978-1612681139/English , Influence: The Psychology Of Persuasion/Robert Cialdini/Harper Business/978-0061241895/English , Quiet: The Power Of Introverts/Susan Cain/Crown Publishing/978-0307352153/English , Leaders Eat Last/Simon Sinek/Portfolio/978-1591845324/English , Factfulness/Hans Rosling/Flatiron Books/978-1250107817/English , The Alchemist/Paulo Coelho/Harperone/978-0061122415/English , Tuesdays With Morrie/Mitch Albom/Broadway Books/978-0767905923/English , The Kite Runner/Khaled Hosseini/Riverhead Books/978-1594631931/English , A Thousand Splendid Suns/Khaled Hosseini/Riverhead Books/978-1594483851/English , Steve Jobs/Walter Isaacson/Simon & Schuster/978-1451648539/English , Elon Musk/Ashlee Vance/Harper/978-0062301239/English , Shoe Dog/Phil Knight/Scribner/978-1501135910/English , Atomic Habits (Illustrated Edition)/James Clear/Penguin Random House/978-1847948250/English , Vinland Saga Vol. 1/Makoto Yukimura/Kodansha Comics/978-1612624204/English , Fullmetal Alchemist: Fullmetal Edition Vol. 1/Hiromu Arakawa/Viz Media Llc/978-1421599779/English , Monster Vol. 1/Naoki Urasawa/Viz Signature/978-1421569062/English , Vagabond Vol. 1/Takehiko Inoue/Viz Signature/978-1421520544/English , Mushoku Tensei: Jobless Reincarnation (Light Novel) Vol. 1/Rifujin Na Magonote/Seven Seas Entertainment/978-1642751383/English , Re:Zero - Starting Life In Another World Vol. 1/Tappei Nagatsuki/Yen On/978-0316310308/English , No Longer Human/Osamu Dazai/New Directions/978-0811204811/English , Norwegian Wood/Haruki Murakami/Vintage/978-0375704024/English , Harry Potter And The Sorcerer’S Stone/J.K. Rowling/Bloomsbury/978-0747532699/English , Harry Potter And The Chamber Of Secrets/J.K. Rowling/Bloomsbury/978-0747538493/English , Harry Potter And The Prisoner Of Azkaban/J.K. Rowling/Bloomsbury/978-0747542155/English , Harry Potter And The Goblet Of Fire/J.K. Rowling/Bloomsbury/978-0747546245/English , Harry Potter And The Order Of The Phoenix/J.K. Rowling/Bloomsbury/978-0747551003/English , Harry Potter And The Half-Blood Prince/J.K. Rowling/Bloomsbury/978-0747581086/English , Harry Potter And The Deathly Hallows/J.K. Rowling/Bloomsbury/978-0747591054/English , One Piece Vol. 100/Eiichiro Oda/Viz Media Llc/978-1974736263/English , Naruto Vol. 72 (Final Volume)/Masashi Kishimoto/Viz Media Llc/978-1421582849/English , Bleach Vol. 1/Tite Kubo/Viz Media Llc/978-1591164418/English , Bleach Vol. 74 (Final Volume)/Tite Kubo/Viz Media Llc/978-1421598260/English , Dragon Ball Z Vol. 1/Akira Toriyama/Viz Media Llc/978-1569319307/English , Dragon Ball Z Vol. 26 (Final Volume)/Akira Toriyama/Viz Media Llc/978-1569319895/English , My Hero Academia Vol. 1/Kohei Horikoshi/Viz Media Llc/978-1421582696/English , Black Clover Vol. 1/Yuki Tabata/Viz Media Llc/978-1421587189/English , Tokyo Revengers Vol. 1/Ken Wakui/Kodansha Comics/978-1646512195/English , Jojos Bizarre Adventure: Part 1 Phantom Blood Vol. 1/Hirohiko Araki/Viz Media Llc/978-1421578798/English , Neon Genesis Evangelion Vol. 1/Yoshiyuki Sadamoto/Viz Media Llc/978-1569319000/English , The Lord Of The Rings Trilogy (Single Volume Edition)/J.R.R. Tolkien/Harpercollins/978-0261102385/English , Bharat Ka Itihas/Ram Saradh Sharma/Oxford India Paperbacks/9118866109/English , Fabric Of Reality/David Deutsch/Penguin Books/978-0140275414/English , Behave/Robert Sapolsky/Penguin Pr/978-1594205071/English , Number Theory/Hari Kishan/Krishna Prakashan Media P. Ltd./978-8182835696/English , Tripura Through The Ages/Naliniranjan Roychowdhury/Jnan Bichitra/B0cp7n7gzh/English , A Handbook On Comprehension And Communication Skills/Yumnam Oken Singh & Gyanabati Khuraijam/Edsol Informatics/978-8198040268/English , Reading Autobiography: A Guide For Interpreting Life Narratives/Sidonie Smith & Julia Watson/University Ofminnesota Press/978-0816669868/English , A Brief History Of Modern India/Rajiv Ahir/Spectrum Books/978-817930812/English , Indian Art And Culture/Nitin Singhania/Mcgraw Hill/978-9355325983/English , Certificate Physical And Human Geography/Goh Cheng Leong/Oxford University Press/978-0195621253/English , Indian Economy/Ramesh Singh/Mcgraw Hill/978-9357066758/English , Environment/Shankar Ias Academy/Shankar Ias Academy/978-8195484897/English , Lexicon For Ethics, Integrity & Aptitude/Chronicle/Chronicle Publications/978-9390977218/English , Indias Ancient Past/R. S. Sharma/Oxford University Press/978-0199479813/English , History Of Medieval India/Satish Chandra/Orient Blackswan/978-9354422237/English , Challenges To Internal Security Of India/Ashok Kumar & Vipul/Mcgraw Hill/978-9355328816/English , Indian Polity For Civil Services/M. Laxmikanth/Mcgraw Hill/978-9357065997/English , The Undiscovered Self/Carl Jung/Mass Market Paperback/978-0451217325/English , Memories, Dreams, Reflections/Carl Jung/Paperback/978-0679723950/English , Modern Man In Search Of A Soul/Carl Jung/Paperback/978-1684220908/English , How To Meet Your Self/Dr. Nicole Lepera/Paperback/978-1398710733/English , Notes To Myself/Hugh Prather/Paperback/978-0553273823/English , Memory, A Very Short Introduction/Jonathan K. Foster/Oxford/978-0192806758/English , The Routledge History Of Literature In English/Ronald Carter And John Mcrae/Routledge/978-1032097572/English , An Introduction To Cultural Studies/Pramod K. Nayar/Viva Books/978-8130933986/English , Mathematical Methods In The Physical Sciences/Mary L. Boas/John Wiley & Sons/978-0471821735/English , Advanced Engineering Mathematics/Erwin Kreyszig/Wiley/978-0470458365/English , Mathematical Physics/H. K. Dass/S. Chand/978-8121908907/English , An Introduction To Mechanics/Daniel Kleppner & Robert Kolenkow/Cambridge University Press/978-1108645537/English , Waves And Oscillation/N.K. Bajaj/Krishna Prakashan Media/978-8178190873/English , Introduction To Electrodynamics/David J. Griffiths/Pearson/978-9332530012/English , Fundamentals Of Statistical Mechanics & Thermal Physics/F. Reif/Mcgraw-Hill/978-0070698144/English , Thermal Physics: Heat & Thermodynamics/H.P. Roy & A.B. Gupta/New Age Publishers/978-8122438404/English , Introduction To Quantum Mechanics/David J. Griffiths/Pearson/978-1107179868/English , Quantum Physics/H.C. Verma/Surya Publication/978-8175150324/English , Solid State Physics/Puri & Babbar/S. Chand/978-8121907610/English , Electronic Devices And Circuit Theory/Robert L. Boylestad & Louis Nashelsky/Pearson/978-9332572006/English , Concepts Of Physics (Part 1 & 2)/H.C. Verma/Bharati Bhawan Publishers/978-8175150287/English , An Introduction To Modern Astrophysics/Bradley W. Carroll & Dale A. Ostlie/Cambridge University Press/978-1292022932/English , Astrophysics In A Nutshell/Dan Maoz/Princeton University Press/978-0691164793/English , Mindset: The New Psychology Of Success/Carol S. Dweck/Random House/978-0345472328/English , Ssc General Studies 7300+ Questions/Kiran Prakasan/Kiran Prakasan/978-9384761543/English , Quantitative Aptitude For Competitive Examinations/R.S. Aggarwal/S. Chand Publishing/978-9352836536/English , A Mirror Of Common Errors/Dr. Ashok Kumar Singh/Student Friends Publications/978-9380222949/English , Fundamental Concepts Of Inorganic Chemistry, Volume 5/Ashim K Das And Mahua Das/Cbs Publishers And Distributors Pvt Ltd/978-8123923529/English , Fundamental Concepts Of Inorganic Chemistry, Volume 6/Ashim K Das And Mahua Das/Cbs Publishers And Distributors Pvt Ltd/978-8123923536/English , Fundamental Concepts Of Inorganic Chemistry, Volume 7/Ashim K Das And Mahua Das/Cbs Publishers And Distributors Pvt Ltd/978-8123923543/English , Gora/Rabindranath Tagore/Rupa/978-8171677559/English , An Introduction To Supramolecular Chemistry/Ashim K Das And Mahua Das/Cbs Publishers And Distributors Pvt Ltd/978-9390158638/English , An Introduction To Nanomaterials And Nanoscience/Ashim K Das And Mahua Das/Cbs Publishers And Distributors Pvt Ltd/978-9388108010/English , Quantum Chemistry/Donald A Mcqurrie/Viva Books/978-8130918945/English , Electrical Machinery Fundamental/Stephen Chapman/Mcgraw Hill Education/978-0071070522/English , Bose : The Untold Story Of An Inconvenient Nationalist/Chandrachur Ghose/India Penguin/978-0071284448/English , India, That Is Bharat Coloniality, Civilisation, Constitution/J Sai Deepak/Bloomsbury India/978-9354350047/English , India, Bharat And Pakistan The Constitutional Journey Of A Sandwiched Civilisation/J Sai Deepak/Bloomsbury India/978-9354354526/English , 1947-1957, India: The Birth Of A Republic/Chandrachur Ghose/India Penguin/978-0670097104/English , The Bose Deception Declassified/Anuj Dhar, Chandrachur Ghose/India Penguin/978-0670097272/English , Bravehearts Of Bharat Vignettes From Indian History/Vikram Sampath/India Penguin/978-0143468004/English , The Common Man At Large Birth Centenary Edition/R K Laxman/India Penguin/978-0143455776/English , Godel, Escher, Bach/Douglas R. Hofstadter/Basic Books; Anniversary Edition (5 February 1999)/978-0465026562/English , The Road To Reality — Penrose/Roger Penrose/Penguin Random House India Pvt Ltd/978-0099440680/English , The Complete Adventures Of Feluda: Volume One: V. 1 /Satyajit Ray/Penguin India/978-0141000145/English , The Complete Adventures Of Feluda, Volume 2/Satyajit Ray/Penguin India/978-0143032786/English , Best Of Agatha Christie(Set Of 4 Books)/Agatha Christie/Mg Books/978-9388600835/English , Linda Goodmans Sun Signs/Linda Goodman/Bantam/978-0330233903/English , Vastu: The Ultimate Guide To Vastu Shastra And Feng Shui Remedies For Harmonious Living/Mari Silva/Independently Published/979-8576957064/English , Distribution System Modeling And Analysis With Matlab® And Windmil® (Paperback, India)/William H. Kersting/Crc Press (Indian Edition Print)/978-1032938608/English , Engineering Mechanics/Russell C. Hibbeler/Pearson/978-9332584747/English , Ikigai [The Japanese Secret]/Francesc García /Hutchinson/978-1786330895/English , Hadoop: The Definitive Guide, 4Th Edition/Tom White/Shroff / O’Reilly Media/978-9352130672/English , That Is Ros(Robot Operating System)/Suman Deb/Ebh Book House/978-9348106605/English , Heart Lamp/Dr. Banu Mushtaq/India Penguin/978-0143464471/English , Semiconductor Physics And Devices, Indian Adaptation/S.M. Sze & M.K. Lee/Willey/978-9354243226/English , The Art Of Happiness/Dalai Lama/Hodder Paperbacks/978-0802131843/English , The Book Of Joy/Dalai Lama, Desmond Tutu/Penguin Random House Ireland Limited/978-1786330444/English , Pax Indica/Shashi Tharoor/Penguin India/978-0143420187/English , Introduction To Machine Learning With Python : A Guide For Data Scientists/Andreas/Shroff/Oreilly/978-9352134571/English , Programming Computer Vision With Python: Tools And Algorithms For Analyzing Images/Solem/Shroff/Oreilly/978-9350237663/English , Web Content Management: Systems, Features, And Best Practices/Barker/Shroff/Oreilly/978-1491908129/English , Data Management At Scale: Modern Data Architecture With Data Mesh And Data Fabric/Strengholt/Shroff/Oreilly/978-9355429896/English , Database Management Systems/Dr. Suganthi/Shroff/X-Team/978-9352136483/English , Practical Machine Learning For Computer Vision: End-To-End Machine Learning For Images/Lakshmanan/Shroff/Oreilly/978-9391043834/English , Indias Struggle For Independence/Bipan Chandra/Penguin Random House/978-0140107814/English , Geography Of India/Majid Husain / D. R. Khullar/Arihant/978-9326194716/English , General Engineering Study Guide For Rrb, Nhpc, Iol, Dmrc, Ongc, Sail, Gail, Upcl And Other Public Sector Examinations/G K Publications/G K Publications/978-9392837654/English , Tata Mcgraw Hill Csat Manual/Tata Mcgraw Hill/Tata Mcgraw Hill/978-9371532600/English , Nta Csir Ugc Net/Set (Jrf & Lectureship) Physical Science/Arihant Expert/Arihant Expert/978-9311009445/English , Csir-Ugc Net/Jrf/Set Physical Sciences/Physics Wallah Private Limited/Upkar Prakashan/978--8174825278/English , Csir - Net Recap Physical Sciences Chapterwise & Yearwise Previous Years Solved Papers (2025-2015)/Physics Wallah Private Limited/Physics Wallah Private Limited/978-9371538640/English , Iit Jam Recap 20 Years Physics Pyq Chapterwise & Yearwise Previous Year Solved Papers (2005-2024) With 5 Mock Tests/Physics Wallah Private Limited/Physics Wallah Private Limited/978-9348057501/English , Nta 68 Ugc Net Paper 1 (Teaching & Research Aptitude)/Physics Wallah Private Limited/Physics Wallah Private Limited/978-9371532600/English , Think And Grow Rich/Napoleon Hill/Tarcherperigee/978-1585424337/English , The Power Of Habit/Charles Duhigg/Random House Trade/978-0812981605/English , The 7 Habits Of Highly Effective People/Stephen R. Covey/Simon & Schuster/978-2133487538/English , How To Win Friends & Influence People/Dale Carnegie/Simon & Schuster/978-0671027032/English , The Gifts Of Imperfection/Brene Brown/Penguin Random House/978-1785043543/English , Big Magic/Elizabeth Gilbert/Fischer Taschenbuch/978-3104035222/English , Getting Things Done: The Art Of Stress-Free Productivity/David Allen/Piatkus/B00shl3v8m/English , Outliers: The Story Of Success/Malcolm Gladwell/Penguin/B002ri9pko/English , Awaken The Giant Within/Tony Robbins/Dlp Publications/?B00azqq1uw/English , Six Not -So-Easy Pieces/Richard P. Feynman/Helix Books/978-0465025268/English , The Feynmann Lectures On Physics/Richard P. Feynman, Robert B. Leighton/Basic Books/978-0465023820/English , Before Religion/Nitesh Gor/Harper Collins/978-9369896486/English , Balance Sheet/Debarati Mukhopadhyay/Deep Prakashan/B0crntn7xr/English , The Road Less Travelled/M. Scott Peck/Rider & Co./978-0712661157/English , The Argumentative Indian/Amartya Sen/Penguin Uk/978-0141012117/English , Materials Characterization Technique/Ashok Kumar, Lin Li, Sam Zhang/Crc Press Inc/978-1420042948/English , Materials Characterization: Introduction To Microscopic And Spectroscopic Methods/Yang Leng/Wiley-Vch/978-0470822982/English , The Selfish Gene/Richard Dawkins/Oxford University Press/978-0198788607/English , Poor Economics/Abhijit V. Banerjee, Esther Duflo/Random House India/978-8184001815/English , Never Let Me Go/Kazuo Ishiguro/Feber & Faber/978-0571258093/English , Lublur Prithibi/Charbak Dipta/Book Farm/978-9348544902/English , Hacking And Security/Michael Kofler, Klaus Gebeshuber/Shroff / O’Reilly Media/978-1493224258/English , Practical Data Privacy - Enhancing Privacy And Security In Data/Katharine Jarmul/Shroff / O’Reilly Media/978-9355429742/English , Machine Learning And Security - Protecting Systems With Data And Algorithms/Clarence Chio, David Freeman/Shroff / O’Reilly Media/978-9352136933/English , Strengthening Deep Neural Networks - Making Ai Less Susceptible To Adversarial Trickery/Katy War/Shroff / O’Reilly Media/978-9352138739/English , 97 Things Every Information Security Professional Should Know/Christina Morillo/Shroff / O’Reilly Media/978-9355420367/English , Learning Kali Linux- Security Testing, Penetration Testing & Ethical Hacking/Ric Messier/Shroff / O’Reilly Media/978-9352137527/English , Basic Electrical Engineering/A. E. Fitzgerald/Mcgraw Hill Education/978-0070682566/English , Electrical Engineering Fundamentals/Vincent Del Toro/Pearson Education India/978-9332551763/English , Mother Mary Comes To Me/Arundhati Roy/Penguine Hamish Hamilton/978-0143473060/English , 100 Great Iitians Book: Dedicated To The Service Of The Nation/Editor Commander V.K. Jaitly/Excel India Publishers/B0dg61mlwq/English , Empowering India Ideas For Action By Scientist And Engineers/Thalappil Pradeep And Krishnan Narayanan/Indian Academy Of Sciences/8195066410/English , What Is Wrong With You?: A Novel/Paul Rudnick/Blackstone Publishing, Inc./978-1668068298/English , The Housemaid/Freida Mcfadden/India Penguin/B0frm2tyk3/English , A Burning/Megha Majumdar/Penguin Hamish Hamilton/978-0670093793/English , The Silent Patient/Alex Michaelides/Celadon Books/978-1409181637/English , 400 Days/Chetan Bhagat/Westland Publication/978-1542094085/English , 12 Years: My Messed-Up Love Story/Rithvik Singh/Fingerprint! Publishing/978-9369896875/English , The Room On The Roof/Ruskin Bond/Puffin/978-0143333388/English , Five Point Someone/Chetan Bhagat/Rupa Publications India/978-8129104595/English , The Power Of Your Subconscious Mind/Jopesh Murphy/Srishti Publishers & Distributors/978-8172345662/English , Dont Believe Everything You Think (English)/Joseph Nguyen/Manjul Publishing House/978-9355431356/English , The Mountain Is You: Transforming Self-Sabotage Into Self-Mastery (English)/Brianna Wiest/Amaryllis (An Imprint Of Manjul Publishing House)/978-1949759228/English , How To Win Friends And Influence People/Dale Carnegie/Srishti Publishers & Distributors/978-0671027032/English , The Psychology Of Money/Morgan Housel/Jaico Publishing House/978-9395970334/English , Dopamine Detox: A Short Guide To Remove Distractions And Get Your Brain To Do Hard Things/Thibaut Meurisse/Wisdom Tree/B098mhbf23/English , A Glossary Of Literary Terms/M.H. Abrams Andgeoffrey Galt Harpham/Cengage India Private Limited/978-8131526354/English , The Art Of Spending Money: Simple Choices For A Richer Life/Morgan Housel/Macmillan/978-1804093696/English , You Become What You Think: Master Your Mind, Master Your Life/Shubham Kumar Singh/Penguin Business/978-0143475279/English , Courage To Be Disliked, The: How To Free Yourself, Change Your Life And Achieve Real Happiness/Ichiro Kishimi And Fumitake Koga/Allen & Unwin/978-1760630720/English , As You Like It/William Shakespeare/Fingerprint Publishing/978-9356524262/English , The Cherry Orchard/Anton Chekhov/Sanage Publishing House Llp/978-0486266824/English , Indias Most Fearless/Aroor Shiv/Penguin Random House India/978-0143440444/English , One Hundred Years Of Solitude/Marquez Gabriel Garcia/Penguin Random House India/978-0198743514/English , Certificate Physical And Human Geography/Leong Goh Cheng/Oxford University Press/978-0195628166/English , Life Is What You Make It/Shenoy Preeti/Srishti Publishers & Distributors/978-9552098987/English , How To Talk To Anyone - Master The Art Of Communication/Leil Lowndes/Harper/978-0007272617/English , India Since Independence/Chandra Bipan/Penguin Random House India/978-0143104094/English , Believe In Yourself/Murphy Joseph/Manjul Publishing House Pvt Ltd/978-8183225090/English , Thus Spoke Chanakya - Ancient Wisdom For Daily Inspiration/Pillai Radhakrishnan/Jaico Publishing House/978-9386867544/English , Satyayoddha Kalki/Missal Kevin/Prakash Books India Private Limited/978-9388369152/English , Lifes Amazing Secrets - Finding Happiness/Das Gaur Gopal/Penguin Random House India/978-0143442295/English , Ghosts Of The Silent Hills/Anita Krishan/Prakash Books India Private Limited/978-9389717136/English , The Castle Of Otranto/Walpole Horace/Sanage Publishing House Llp/978-8196160418/English , Ruskin Bond Horror Omnibus/Bond Ruskin/Rupa Publications India Pvt. Ltd/978-8129112552/English , One Indian Girl/Bhagat Chetan/Rupa Publications India Pvt. Ltd/978-8129142146/English , The Monk Who Sold His Ferrari - Monk Sold His Ferrari/Sharma Robin S./Jaico Publishing House/978-8179921623/English , Me Before You - Me Before You/Moyes Jojo/Penguin Books Ltd/978-0718157838/English , Dark Horse/Mrinal Nilotpal/Hind Yugm/978-9386850591/English , The Immortals Of Meluha/Amish Tripathy/Harper360/978-9356290525/English , The Chola Tigers: Avengers Of Somnath - A Historical Fiction By Amish/Amish Tripathy/Harpercollins Publishers/978-9369896097/English , Same As Ever/Morgan Housel/Harriman House/978-1804090947/English , Pearson Nta Ugc Net 2025 Paper 1/Kvs Madaan/Pearson Education/B0f4wvj28z/English , 1232 Km : The Long Journey Home/Vinod Kapri/Harpercollins Publishers India/978-9354226519/English , Stars Will Guide You Home/Stuti Changle/Harpercollins Publishers India/978-9369890651/English , Ponting : At Close Of Play/Ricky Ponting/Harpercollins Publishers India/978-9351160717/English , The Power Of Curiosity/Anita Karwal/Harpercollins Publishers India/978-9356296671/English , What To Think About Machines That Think/John Brockman/Harpercollins Publishers India/978-0062425652/English , Daiva : Discovering The Extraordinary World Of Spirit Worship/K. Hari Kumar/Harpercollins Publishers India/978-9354899744/English , Pursuit Of Happyness/Chris/Jones Gardner/Harpercollins Publishers India/978-0060744878/English , India’S Wars Ii : A Military History 1972-2020/Arjun Subramaniam/Harpercollins Publishers India/978-9365696325/English , Hitler And India/Vaibhav Purandare/Harpercollins Publishers India/978-9356293151/English , Tagore In Tripura/Khagesh Dev Burman/Harpercollins Publishers India/978-9369895250/English , Ramayanam : Khand 1/Dushyanth Sridhar/Harpercollins Publishers India/978-9362136039/English , 14 : Stories That Inspired Satyajit Ray/Bhaskar Chattopadhyay/Harpercollins Publishers India/978-9351361930/English , Revolutionaries : The Other Story Of How India Won Its Freedom/Sanjeev Sanyal/Harpercollins Publishers India/978-9356295940/English , 11 Rules For Life : Secrets To Level Up/Chetan Bhagat/Harpercollins Publishers India/978-9356999978/English , Lockwood & Co./Jonathan Stroud/Penguin/978-0241613122/English , On The Open Road/Stuti Changle/Penguin/?978-0143453680/English , Shivaji : The Great Maratha/Ranjit Desai/Harpercollins Publishers India/978-9352774395/English , An Ordinary Life : Portrait Of An Indian Generation/Ashok Lavasa/Harpercollins Publishers India/978-9354223174/English , Attitude Is Everything/Jeff Keller/Harpercollins Publishers India/978-9351772071/English , I Came Upon A Lighthouse : A Short Memoir Of Life With Ratan Tata/Shantanu Naidu/Harpercollins Publishers India/978-9354897412/English , Why Not Me? A Feeling Of Millions/Anubhav Agrawal/Harpercollins Publishers India/978-9390351473/English , Write Me A Love Story/Ravinder Singh/Harpercollins Publishers India/978-9354223204/English , The Troubled Deep/Rob Parker/Bloomsbury Publishing/B0d81gzsbj/English , The Last Murder At The End Of The World/Stuart Turton/Bloomsbury Publishing/978-1526634924/English , Twelfth Fail : Hara Vahi Jo Lada Nahi/Anurag Pathak/Harpercollins Publishers India/B09nl46tts/English , Days At The Morisaki Bookshop:/Satoshi Yagisawa/Manilla Press/978-1786583239/English , Indias Near East/Avinash Paliwal/Penguin/978-1805260615/English , Incredible History Of Indias Geography/Sanyal Sanjeev/Penguin Books Limited/978-0143333661/English , Stalingrad/Antony Beevor/Penguin Books Limited/978-0141032405/English , The Last Kids On Earth And The Nightmare King/Max Brallier/Egmont/978-1405295116/English , The Microsoft Story/Dan Good/Harpercollins Publishers India/978-1400223909/English , A Samurai Dream Of Azad Hind: Rash Behari Bose/Prasun Roy/Vitasta Publishing Pvt.Ltd/978-9390961849/English , Before I Forget: A Memoir/M.K. Raina/Vintage Books/978-0670098811/English , His Last Bow/Arthur Conan Doyle/Fingerprint Publishing/978-9354406256/English , Ai Snake Oil/Arvind Narayanan, Sayash Kapoor/Penguin/978-0691249131/English , The Thousand Autumns Of Jacob De Zoet/David Mitchell/Sceptre/978-0340921562/English , Battles Of Our Own/Mohanty Jagadish/Penguin Modern Classics/978-0143451747/English , The Power Of Letting Go/John Purkiss/Octopus Books/978-1783253630/English , The Light Of Love And Other Stories/Ashutosh Agnihotri/Har-Anand Publications Pvt Ltd/978-8196403959/English , Wings Of Valour : True Stories Of The Indian Air Forces Daring Operations/Swapnil Pandey/Harpercollins India/978-9369891733/English , The Eleventh Hour/Salman Rushdie/Penguin Hamish Hamilton/978-1787336049/English , The In-Laws/James Caine/India Penguin/979-8835781669/English , Call It Coincidence/Nona Uppal/Penguin Ebury Press/978-0143471547/English , Crossing Over/Kaushik Mitra/India Penguin Enterprise/B0frzjggvt/English , The Loneliness Of Sonia And Sunny/Kiran Desai/Penguin Hamish Hamilton/978-0307700155/English , Flesh/David Szalay/Jonathan Cape/978-0224099790/English , Tomb Of Sand/Geetanjali Shree/Penguin/978-0143448471/English , Eileen/Ottessa Moshfegh/Penguin Group Usa/978-0143128755/English , A Plane Story/Anmol Malik/Harpercollins India/978-9354890246/English , Too Good To Be True/Prajakta Koli/Harper Fiction/978-9365693393/English , The India Way : Strategies For An Uncertain World/S. Jaishankar/Harpercollins Publishers India/978-9394407213/English , Pride And Prejudice/Jane Austen/Fingerprint! Publishing/978-8172344504/English , Playing It My Way/Sachin Tendulkar/Hodder & Stoughton/978-1473605176/English , Can We Be Strangers Again?/Shrijeet Shandilya/Penguin Ebury Press/978-0143475927/English , After The Storm/Lakshmy Ramanathan/Harpercollins India/978-9353020286/English , Tara Goes Aahhhhh/Sam Dalrymple/Harper Childrens/978-9365693508/English , Youth And Truth : Unplug With Sadhguru/Sadhguru/Harpercollins India/978-9354895401/English , An Ordinary Life : Portrait Of An Indian Generation/Ashok Lavasa/Harpercollins/978-9354223174/English , The Journey To Adi Kailash/K. Ramachandran/Penguin Ebury Press/978-0143461340/English , In An Antique Land/Amitav Ghosh/Penguin India/978-0143066491/English , Tales Of The Open Road/Ruskin Bond/Penguin India/978-0144000722/English , Diary Of A Young Girl/Anne Frank/Penguin/978-8172345198/English , 1984/George Orwell/Fingerprint! Publishing/978-8192910901/English , Animal Farm/George Orwell/Penguin India/978-0143416319/English , Sapiens: A Brief History Of Mankind/Yuval Noah Harari/Penguin Random House/978-0099590088/English , Midnights Children/Salman Rushdie/Random House Trade Paperbacks/978-0812976533/English , The Glass Palace/Amitav Ghosh/Harpercollins/978-0008279486/English , The Inheritance Of Loss/Kiran Desai/Grove Press/978-0802142818/English , A Tale Of Two Cities/Charles Dickens/Pan Macmillan India/978-1509848997/English , Learn, Don’T Study/Pramath Raj Sinha/Penguin Business/978-0670097487/English , The Room On The Roof, Vagrants In The Valley/Ruskin Bond/Penguin India/978-0140239591/English , The Guide/R.K. Narayan/Indian Thought Publications/978-8185986074/English , The Tripua Language/Prof. Deb Dulal Tripura/Prof. Deb Dulal Tripura/Latest/English , In A Forest, A Deer/Ambai/Oxford University Press/978-0198080015/English , English, August: An Indian Story/Upamanyu Chatterjee/Faber & Faber/978-0571345892/English , Sunlight On A Broken Column/Attia Hosain/Penguin India/978-0143066484/English , The Heart Has Its Reasons/Mehak And Kripanarayan/Katha,India/978-8187649540/English , Year Of The Tiger/Sohaila Abdulali/Penguin Books India - Penguin/978-0143067856/English , Things Fall Apart/Chinua Achebe/Rhus/978-0385474542/English , Last Man In Tower/Aravind Adiga/Atlantic Books/978-1848875180 /English , Untouchable/Anand/Pearson Education India/978-8131707258 /English , Why We Dont Talk/Shinie Antony/Rupa/978-8129116529/English , Life After Life/Kate Atkinson/Black Swan/978-0552776639/English , When I Hid My Caste/Baburao Bagul/Speaking Tiger Books/978-9386702951/English , The Enemy Within/Bani Basu/Orient Blackswan/978-8125016687/English , This Side Of Paradise/F. Scott Fitzgerald/Penguin/978-0141185576/English , Flood Of Fire/Amitav Ghosh/Penguin Books India/978-0143426127/English , Time Travel/James Gleick/Fourth Estate/978-0007544455/English , Dune/Frank Herbert/Penguin Usa/978-0441172719/English , Partitions/Kamleshwar/Penguin India/978-0143063704/English , Dear Life/Alice Munro/Vintage/978-0099578635/English , Fathers And Sons/Ivan Turgenev/Notion Press/978-1639044481/English , Monkey-Man/K. R. Usha/Penguin India/978-0143068563/English , The Invisible Man/H. G. Wells/Scholastic/978-1365700729/English , Inside The Box: A Proven System Of Creativity For Breakthrough Results/Drew Boyd/Simon & Schuster/978-1451659290/English , The Artist In The Machine: The World Of Ai-Powered Creativity/Arthur I. Miller/The Mit Press/978-0262042857/English , Design Your Thinking/Soni Pavan/Penguin Random House India Private Limited/978-0670094097/English , Turning Points : A Journey Through Challenges/A.P.J Abdul Kalam/Harper India/978-9350293478/English , What I Did Not Learn At Iit-Special/Rajeev Agarwal/Random House India/978-8184007619/English , A Modern Approach To Verbal & Non-Verbal Reasoning/R.S. Aggarwal/S Chand Publishing/978-9352832163/English , Connect The Dots/Rashmi Bansal/Iim/978-8190453028/English , Poor Little Rich Slum/Rashmi Bansal/Westland/978-9381626184/English , And The Lion Smiled At The Rabbit/Rashmi Datt/Wisdom Tree/978-8183282543/English , Power Of Habit/Charles Duhigg/Random House Books/978-1847946249/English , Youre Hired/Nasha Fitter/Penguin India/978-0143100577/English , Olive Kitteridge/Elizabeth Strout/Random House Trade Paperbacks/978-0812971835/English , Collective Choice And Social Welfare/Amartya Sen/Penguin/978-0141982502/English , Impossible To Possible/R.C. Bhargava/Bloomsbury India/978-9356405301/English , Annihilation Of Caste/B.R. Ambedkar/Navayana/979-8511230634/English , The Thursday Murder Club/Richard Osman/Penguin Books/978-1984880987/English , Annie On My Mind/Nancy Garden/Square Fish/978-0374400118/English , Akata Witch: 1/Nnedi Okorafor/Penguin Usa/978-0670011964/English , Bamboo People/Mitali Perkins/Charlesbridge/978-1580893299/English , Attack On Titan 1/Hajime Isayama/Kodansha Comics/978-1612620244/English , The Battle Of Jericho/Sharon M. Draper/Atheneum/Caitlyn Dlouhy Books/978-1481490290/English , Fault In Our Stars/John Green/Penguin/978-0141345659/English , Forever/Judy Blume/Macmillan Childrens Books/978-1447281047/English , Jacob Have I Loved/Katherine Paterson/Harpercollins Childrens Books/978-0064403689/English , Jumped/Rita Williams-Garcia/Quill Tree Books/978-0060760939/English , Separate Peace/John Knowles/Scribner/978-0743253970/English , The 57 Bus/Dashka Slater/Wren & Rook/978-1526361233/English , Six Months To Live/Lurlene N. Mcdaniel/Darby Creek Publishing/978-1581960037/English , We Are Okay/Nina Lacour/Dutton Books For Young Readers/978-0525425892/English , We Were Liars/E. Lockhart/Hot Key Books/978-1471418761/English , Of Mice & Men/John Steinbeck/Penguine/978-0141185101/English , The Happiness Equation/Neil Pasricha/Random House/978-1785041204/English , Brain Rules/John Medina/Pear Press/978-0983263371/English , Physics Of The Impossible/Michio Kaku/Anchor/978-0307278821/English , Eleven Minutes/Paulo Coelho/Harpercollins Publishers/B0cyblyh9m/English , The Tattooist Of Auschwitz/Heather Morris/Harpercollins/978-0062797155/English , Paper Moon/Rehana Munir/Harpercollins India/978-9353574000/English , Johnny Gone Down/Karan Bajaj/Harpercollins India/978-9352642915/English , The Lovely Bones/Alice Sebold/Picador/978-0330485388/English , Anna Karenina/Leo Tolstoy/Penguin/978-0140449174/English , Into The Wild/Jon Krakauer/Vintage Books/978-0385486804/English
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 4
44.
Educational and Research Institute #9763611 Technical Bid
Supply And Installation Of Furniture At Iim Jammu Foundation For Entrepreneurship Innovation And Skill Development Iimj-Feisd , Round Coffee Table - Providing, Supplying & Placing Of Round Coffee Table 600 Mm Dia X 450 Mm Height Having Top Made Up Of Ply Wood - 18Mm Thick. The Top Should Be In 1 Mm Laminate & Base In 0.8 Mm Laminate, Color Matching To Running Color Scheme Or As Desired By The Engineer In Charge. All The Edges Should Be Finished With Glued - On Polypropylene Edge Bands With Corner And Edge Rounding, Enabling Zero Sharp Elements Environment. There Should Be Powder Coated Base In Trirod Pattern Made Up Of 18 Mm Dia Round Bright Bar And The Powder Coating Of All The Metal Units Must Be Of 70 Micron 7 Tank Process With Oven Baking Powder Coated From Approved Make. The Minimum Factor Of Safety Is 1.65 On Yield Stress, The Allowable Deflection Will Be Limited To Span/200. The Item Should Include All Other Features As Shown In Photograph And 3D Views But Missed In Description All Complete As Per The Direction Of Engineer In Charge. , Revolving Mesh Chair - Providing, Supplying & Fixing Revolving Mesh Chair With Overall Dimension: 570 W X 530 D X 890-1000 H Mm Having Seat Ht. 390 - 510Mm. The Revolving Chair With Center Pivot Mechanism With 360 Degree Swivel, 17 Degree Tilt, Tilt Tension Adjustment, Upright Locking, Pneumatic Height Adjustment. 117.5 Cm H, Seat Are Made Up Of 1.2Cm Thick Hot Pressed Plywood, Upholstered With Fabric And Moulded Polyurethane Foam (Moulded With Minimum Density = 45 +/- Kg/M3 And Hardness = 20 +/- 2) Together With Moulded Seat And Back Covers. The Back Is Designed With Contoured Lumbar Support For Extra Comfort. Mesh Is Provided To Support To Back As The Shape Of The Back. The Seat Is Covered With Injection Moulded In Black Co-Polymer Polypropylene, And The Back Cover Is A Vacuum Formed From An Abs Sheet. Armrests Made Of Black Integral Skin Polyurethane With 50 - 70 Shore A Hardness And Reinforced With Ms Insert. The Armrests Are Scratch And Weather-Resistant. The Armrests Are Fitted To The Seat With A Seat/Armrest Connecting Strip Assembly Made Of 0.5Cm Thick Hr Steel. The Pedestal Is Made Of Hr Steel And Fitted With 5 Nos. Twin Castors (Twin Wheel Castors Are Injection Moulded In 30% Glass-Filled Black Nylon) Complete. The Item Includes All Other Features As Shown In The Photograph And 3D Views But Is Missed In The Description All Complete As Per Direction Of Engineer In Charge. , Medium Height Storage - Providing, Supplying & Fixing Storage With Size : 900 W X 450 D X 750 H Mm Complete Having The Top Is Made Up Of 25Mm Plywood. Side And Back Are Made Up Of 18Mm Thick Plywood. Storage Is Assembled With 2 Drawers & 2 Shutters With One Shelf Inside Shutters. The Plywood Should Be With 1 Mm Laminate Both Side With Color Matching To Running Color Scheme Or As Per The Direction Of Enginer In Charge.All Edges Finished With Glued - On Polypropylene Edge Bands With Corner And Edge Rounding, Enabling Zero Sharp Elements Environment & Edge Band Shall Be 2.0 Mm And Each Drawer And Shutter Shall Have Handle Options- Bow Type, Knobs & Stainless Steel Handles. The Base Shall Have Basic Straight Skirting. The Item Include All Other Features As Shown In Photograph And 3D Views But Missed In Description All Complete As Per Direction Of Engineer In Charge. , Workstation Table With Pedestal - Providing, Supplying & Fixing Of Workstations Of Size (4 Seats) 2100 W X 1100 D X 750 H Mm With Pedestal Storage And The Following Specifications: Frame Work, Partition And Cable Management : Frame Work Shall Consist Of Main Spine And Return Spine Of Aluminium Extruded Section Of Minimum Thickness Of 1.2 Mm. The Overall Thickness Of Panel Based System Shall Be Minimum 60-70 Mm. The Thickness Of Main Spine Partition Panel Shall Be Minimum 60-70 Mm & Minimum 25-28Mm/60 Mm Thick For Return Spine. The Panel Will Be Hollow From Inside To Accommodate Wiring For Electrical/Data And Outer Frame Of Panel Should Be Made Of Extruded Aluminium.The Panel Shall Be Made Up Of 3 Mm Thick Mdf Both Sides Of The Wooden Frame To Create The Hollow For The Wire Management. The Panel Outer Aluminium Frame Is Designed In Such A Way That It Can Be Easily Slide In To The Columns/ Connectors By Means Of Stacking One Over The Other. Horizontal Race Way Shall Be 150-170 Mm Height Aluminium Profile. There Shall Be A Complete Cable Management Arrangement With An Openable Raceway Above/ Below The Worktop With Provision For Fitting Electrical/Data Switches And Holes For Passing Cable. Panel Finishes: Finishes Of The Panel Above The Worktop Can Be Fabric Pinup/Fabric/Laminate + Glass/Metal Writable Marker Board Or Single Finish Tile With A Raceway On The Main Spine—Finishes Of The Main Spine Panel Below The Worktop. The Hollow Panel Should Be Made Of Mdf Tile And 0.5Mm Thick Steel Sheet Pasted On Mdf, Powder Coated With Epc Finish 80-90 Microns For Durability On The Inside As Well On The Outside. Raceway Can Be Provided Above/Below The Worktop. Connectors/ Brackets: Aluminum End Post, Two Way, Three Way, Four Way Post Provided As Per Design. Brackets For Top Support And Connectors Made Of 1-1.2Mm Thk Metal With Powder Coating Of Desired Color. Worktop : Worktop Made Up Of 25Mm Thick Plywood Finished With 1 Mm Laminate On Top And Bottom With 2Mm Abs Edge Banding. The Exposed Edge Of The Worktop Shall Be Secured With 2Mm Thick Pvc Edge Banding Tape Of Approved Colour. The Height Of The Worktop Shall Be 740-760 Mm From Ground Level. Drawer Unit : 3 Drawer Metal Pedestal Of Overall Dimensions Internal And External Dimensions 400 Mm (W) X 450 Mm (D) X 600 Mm ( H). Drawer Body Should Be Made Of Crca Of Thickness 0.7-0.8 Mm Duly Powder Coated With 70-80 Micron. Each Pedestal Should Have 5 Nos Castor Fitted To It Where In One Castor Will Be Fitted To Lower Most Drawer To Provide Extra Stability. The Item Includes All Other Features As Shown In The Photograph And 3D Views But Is Missed In The Description All Complete As Per Direction Of Engineer In Charge. , 2 Seater Sofa Type 1 - Providing, Supplying & Fixing A 2-Seater Sofa With Size: (1440 W X 850 D X 779 H Mm) Made Up Of A Basic Structure Of 16-Gauge 25 Mm X 25 Mm Metal Wielded Structure Covered With 6Mm Ply To Provide Shape & It Shall Be Wrapped With 50 Density High-Density Foam & Further With Commercial Grade Fabric. Fabric Should Be Fire Retardent Fabric. The Ss Studs Legs Shall Be Provided At The Base. All Item Shall Be Upholstered With Removable Polyester Fabric Having Martin - Dale Abrasion Resistance >= 40000 Cycles, Color Fastness To Lighting - 4 To 5, Composition -100% Polyester And Weight - 330 Gsm. The Item Includes All Other Features As Shown In Photograph And 3D Views But Missed In Description All Complete As Per Direction Of Engineer In Charge. , Rectangular Coffee Table - Providing, Supplying & Fixing Coffee Table Size - 900 W X 600 D X 450 H Mm Having Top Made Up Of 18 Mm Thick Plywood. The Top Should Be In 1 Mm Laminate & Base In 0.8 Mm Laminate, Color Matching To Running Color Scheme Or As Desired By The Engineer In Charge. All The Edges Should Be Finished With Glued - On Polypropylene Edge Bands With Corner And Edge Rounding, Enabling Zero Sharp Elements Environment. There Should Be Powder Coated Base In Trirod Pattern Made Up Of 18 Mm Dia Round Bright Bar And The Powder Coating Of All The Metal Units Must Be Of 70 Micron 7 Tank Process With Oven Baking Powder Coated From Approved Make. The Minimum Factor Of Safety Is 1.65 On Yield Stress, The Allowable Deflection Will Be Limited To Span/200. The Item Should Include All Other Features As Shown In Photograph And 3D Views But Missed In Description All Complete As Per The Direction Of Engineer In Charge. , 3 Seater Sofa- Providing, Supplying & Fixing A 3-Seater Sofa With Size: (2010 W X 850 D X 779 H Mm) Made Up Of A Basic Structure Of 16-Gauge 25 Mm X 25 Mm Metal Wielded Structure Covered With 6Mm Ply To Provide Shape & It Shall Be Wrapped With 50 Density High-Density Foam & Further With Commercial Grade Fabric. Fabric Should Be Fire Retardent Fabric. The Ss Studs Legs Shall Be Provided At The Base. All Item Shall Be Upholstered With Removable Polyester Fabric Having Martin - Dale Abrasion Resistance >= 40000 Cycles, Color Fastness To Lighting - 4 To 5, Composition -100% Polyester And Weight - 330 Gsm. The Item Includes All Other Features As Shown In Photograph And 3D Views But Missed In Description All Complete As Per Direction Of Engineer In Charge. , High Table- Providing, Supplying & Fixing Of High Table Of Size 1500 W X 500 D X 1050 H Mm. The Top Should Be Made Up Plywood Of 25 Mm Thick, Finished With A 1 Mm Laminate On Top And 0.8Mm Laminate At Bottom. All Edges Are Finished With Glued-On Polypropylene Edge Bands With Corner And Edge Rounding, Enabling Zero Sharp Elements Environment. It Shall Be Provided With Ms 2 Mm Thick Metal Powdercoated Base In 50 Mm X 25 Mm Top Pipe Supported With 32 Mm Dia. Round Pipe. The Powder Coating Of All The Metal Units Must Be Of 70 Micron 7 Tank Process With Oven Baking Powder Coated. The Minimum Factor Of Safety Considered Is 1.65 On Yield Stress. The Allowable Deflection Will Be Limited To Span/200. The Item Includes All Other Features As Shown In The Photograph And 3D Views But Is Missed In The Description. , Height Adjustable Table- Providing, Supplying & Fixing Of Height Adjustable Table Of Size 1200 W X 600 D X 610/1255 H (Leg Height Minimum 605Mm & Maximum 1255Mm). Worktop : Worktop Made Up Of 25Mm Thick Plywood Finished With 2Mm Abs Edge Banding. The Exposed Edge Of The Worktop Shall Be Secured With 2Mm Thick Pvc Edge Banding Tape Of Approved Colour. Height Adjustable Workstations Worktop Supported On Ms Electrical Leg . Understructure: The Understructure Is Made Of 2Mm Thick Steel Square Pipe Dimension 75 X 75 Mm With Epoxy Powder Coated Spray Paint, Baked At Temperature 200 C° Coated Of 70-80 Micron Thickness. Powder Coating Should Be Scratch Resistance (Cross Hatch Test 6X6 Grid Method).Legs Connected With Steel Pipe With Epoxy Powder Coated Spray& Beam At Temperature 200C°. Leg Height Minimum 605Mm & Maximum 1255Mm From Ground Level.Motro Speed Is 36Mm Per Second And Stroke Is 650Mm.The Flexible Vertical Wire Manager Shall Accommodate Height Of 605-1255Mm. Brackets Are Made Of 2.0Mm Thick Crca Grade D Steel As Per Is : 513. Brackets Are Slide In Between End Trim And Vertical Extrusions. Workstation Should Have 28Mm Thick Fabric Pinup+ Marker Board Screen With Aluminum Frame With Accessories Bar To Hang The Accessories Andheight 310-360Mm From The Worktop.Screen Should Be Fixed On Ms Powder Coated Brackets 80-90 Microns.Each Workstation Should Be With Fixed With Wiring Tray Made Of Steel Sheet Thickness 1.2Mm. Wire Management: Completely Concealed Wire Management With Vertical Wire Uptake From Floor Viaflexible Vertical Wire Manager , Segregates To Horizontal Cable Tray Below Aluminum Flipper With Soft Closure Epoxy Powder Coated Spray Color, Baked At Temperature 200 C°. Raceways Contain The Horizontal Cable Channel That Fitted Below The Top With Supported Brackets. Epoxy Powder Coated Spray Paint, Baked At Temperature 200 C° Coated Of 80-90 Micron Thickness. Powder Coating Should Be Scratch Resistance (Cross Hatch Test 6X6 Grid Method). The Exposed Edge Of Worktop Shall Be Secured With 2Mm Thick Pvc Edge Banding Tape Of Approved Colour. The Height Of The Worktop Shall Be 740-760 Mm From Ground Level. Drawer Unit : 3 Drawer Metal Pedestal Of Overall Dimensions Internal And External Dimensions 380-430 Mm (W) X 430-480 Mm (D) X 600-620 Mm ( H). Drawer Body Should Be Made Of Crca Of Thickness 0.7-0.8 Mm Duly Powder Coated With 70-80 Micron. Each Pedestal Should Be Provided With Pencil Tray Of 40-45 Mm(H) X 110-120 Mm (D) X 300-310 Mm (W). Each Pedestal Should Have 5 Nos Castor Fitted To It Where In One Castor Will Be Fitted To Lower Most Drawer To Provide Extra Stability. The Item Includes All Other Features As Shown In The Photograph And 3D Views But Is Missed In The Description. , Movable Notice Board- Providing & Fixing Of Movable Notice Board Of Size-1243 W X 600 D X 1850 H Mm Tri Wheel Board (One Side Writable & One Side Pinup Board) Made Up Of 9 Mm Acoustic Sheet Wrapped With Suitable Fabric As Appvd By Designer. Structure Made Up Of 25 X 25 Mm Square Pipe Of 16 Gauge Thickness Finished With Powdercoating. Powder Coating Of All The Metal Units Must Be Of 70 Micron 7 Tank Process With Oven Baking Powder Coated. The Minimum Factor Of Safety Considered Is 1.65 On Yield Stress.The Allowable Deflection Will Be Limited To Span/200. Provided With 50 Mm Dia Cators At Base For Easy Movement. Ms With Metal Powder Coating . Wheels With Locking System. Whiteboard With Ceramic Coating. The Item Includes All Other Features As Shown In The Photograph And 3D Views But Is Missed In The Description. , Pentagon Ottoman- Providing, Supplying & Fixing Of Pentagon Ottoman 549 W X 523 D X 450 H Mm With Structure Made Up Of Polyurethane Foam Block Of Approved Quality Supported With 18Mm Thick Ply At The Bottom To Fasten 50X25 Mm Nylon Glides Below It. Approved Pu Foam To Have Density Of 50 + Or - 2 Kg/M3 Having Premium Grade With Moderate Resilience Shall Be Provided. Bent Plywood Used For Cnstruction Of Walls. 2. Fabric Upholstery With 350 Gsm, Abrasion Resistance >= 20000 Cycles, And Fire Retardant.50 Density Foam. Pvc Legs Bottom Feet 50 X 25 Mm Nylon Glides Shall Be Provided Below It As Per Direction Of Engineer In Charge. The Item Includes All Other Features As Shown In The Photograph And 3D Views But Is Missed In The Description. , 2 Seater Sofa Type 2- Providing, Supplying & Placing 2 2-Seater Sofa Seating Of Size 1200W X 741D X 825H Mm, Two-Seater Upholstered Sofa Featuring A Solid High-Density Machine-Injected Foam Seat And Backrest, Ensuring Long-Lasting Comfort And Durability. Its Internal Structure Is Crafted From Ms (Mild Steel) Or Wooden Framing, Providing Strength And Stability. The Sofa Is Elegantly Upholstered With Fabric Of Approved Finish And Colour, Offering A Premium Aesthetic. Supported By Wooden-Finish Legs, The Base Ensures A Sturdy Foundation While Enhancing The Overall Fabric Of 350-500 Gsm, The Density Of The Foam Is 50+Or- 2 Kg/M3, Fire Retardant Fabric, Dried Kiln Pinewood Frame, Wooden Legs For Sofa. , High Stool- Providing & Supplying High Bar Stool Size: 480Wx 440Dx 990Hmm & Seating Height Is 760 Mm, Featuring An Ergonomically Designed Curved Seat With An Integrated Backrest, Providing Enhanced Comfort And Support. The Seat Is Crafted With Moulded Foam Padding Over A Sturdy Wooden Or Ms Frame And Upholstered In Premium Leatherette Or Fabric As Per The Approved Finish And Colour. The Sleek Metal Base With A Powder-Coated Finish Ensures Durability And Corrosion Resistance, While The Minimalist Sled-Style Legs Offer Stability And A Contemporary Aesthetic. An Integrated Footrest Adds Extra Comfort And Non-Slip Foot Caps Prevent Scratches On The Floor. , 2 Seater Sofa Type-3- Providing & Placing Sofa, Structure Pressed And Moulded Wood Of Size 1240 W X 622 D X 736 H Mm, Supported By Plywood In Base. The Cushion Is Molded High-Density Foam (Polyurethane Foam) And Jacketed With Fabric With Stainless Steel Legs Designed In A U Shape. The Component Specification Shall Be As Follows Fabric Of 350-500 Gsm, Seat-50 Kg/Cum Density Pu Foam, 100Mm Thick, Back–32-40Kg/Cum Density Pu Foam, 50Mm Thick, Sides (Inside) - 32-40 Kg/Cum Density Pu Foam, Fire Retardent Fabric, 11Mm Thick Sides (Outside) & Back (Back Side)-35-40 Kg Cum Density Pu Foam, 13Mm Thick. The Seat Shell Rests On Stainless Steel Legs. , Square Coffee Table- Providing, Supplying & Fixing Square Coffee Table Size - 600 W X 600 D X 450 H Mm Having Top Made Up Of 25Mm Plywood. The Top Should Be In 1 Mm Laminate & Base In 0.8 Mm Laminate, Color Matching To Running Color Scheme Or As Desired By The Engineer In Charge. All The Edges Should Be Finished With Glued - On Polypropylene Edge Bands With Corner And Edge Rounding, Enabling Zero Sharp Elements Environment. There Should Be Powder Coated Base In Trirod Pattern Made Up Of 18 Mm Dia Round Bright Bar And The Powder Coating Of All The Metal Units Must Be Of 70 Micron 7 Tank Process With Oven Baking Powder Coated From Approved Make. The Minimum Factor Of Safety Is 1.65 On Yield Stress, The Allowable Deflection Will Be Limited To Span/200. The Item Should Include All Other Features As Shown In Photograph And 3D Views But Missed In Description All Complete As Per The Direction Of Engineer In Charge. , Overhead Storage- Providing And Placing Overhead Storage, With A Body Constructed From 18 Mm Thick Plywood In Vertical Member And 25 Mm Thick Horizontal Member For Durability And Strength. The Shutters Are Made From 18Mm Thick Plywood, Featuring 2Mm Pvc Edge Banding For Enhanced Protection. Each Shutter Is Fitted With An Extruded Stainless Handle, Ensuring A Sleek And Functional Design. The Complete Storage Should Be Lamintaed With 1 Mm Laminate Of The Desired Colour From All Sides And Faces, Before Mounting On Wall. The Storage Unit Is Equipped With A Three-Way Locking Mechanism, Allowing The Hinged Doors To Be Securely Locked At Once. Additionally, The Hinge-Damping Mechanism Enables Soft Closing For Noise Reduction And Smooth Operation. These Overhead Storage Units Can Be Mounted On Panels Or Walls. The Specified Wall-Mounted Storage Measures 20 Ft (L) X 2.5 Ft (H) And Is Aligned With Five Workstations, Providing Ample Organized Storage For Workspace Efficiency. The Item Should Include All Other Features As Shown In The Photograph And 3D Views But Missed In The Description. All Are Complete As Per The Direction Of The Engineer In Charge. , Desk Based Workstation- Providing And Placing Desk Based Workstations With Pedstal With Following Specifications Of Size 1200 Mm X 750 Mm X 750 Mm Height Understructure, Screen And Cable Management : Desk Based System Worktop Supported On Understructure Made Of Ms Legs Sq/ Tapered Leg Of Section 38 X 38Mm, Where Structure Made From Cold Rolled Steel,Thickness 1.2 Mm. Epoxy Powder Coated Spray Paint, Baked At Temperature 200 C° Coated Of 70-80 Micron Thickness. Powder Coating Should Be Scratch Resistance (Cross Hatch Test 6X6 Grid Method). Screen: 28Mm Thick Offset Fully Alumium Frame Screen With Combination Of Fabric Pinup &Marker Board , For Back To Back Workstation, Screen Height Is 360Mm Above The Top &For Non Sharing/ Single Side Screen Plus Modesty Panel To Be Considered. Wire Management: Completely Consealed Wire Management With Vertical Wire Uptake From Floor Via Ms Power Pole Having Removable Cover One Side And Wire Seperator For Data And Wire Seperation, Segregates To Hozizontal Cable Tray Below Aluminium Flipper With Soft Closure Epoxy Powder Coated Spray Color, Baked At Temperature 200 C°. Raceways Contain The Horizontal Cable Channel That Fitted With A Modesty Panel Tidily And Effectively. Epoxy Powder Coated Spray Paint, Baked At Temperature 200 C° Coated Of 80-90 Micron Thickness. Powder Coating Should Be Scratch Resistance (Cross Hatch Test 6X6 Grid Method). Worktop: Worktop Made Of 25Mm Thick Plywood Finished With 2Mm Pvc Edge Banding. E1 Grade Laminate With Zero Urea Formaldehyde Emissions (
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
45.
Defence #9749550 AOC
Tender For Provision Of Deficient Married Accommodation At Air Force Station Phalodi Boq (11 Aug 2025).; 1 NOTE: Schedule ‘A’ Part I to XII under Ser No. 1.00to 12.00 are prepriced by MES. Bidders shall insert their lumpsum amount in the green coloured field under Col-6 only. 2 Lump sum price worked outfor BUILDINGS/ STRUCTURES as listed in Sch A Part I. 3 Lump sum price worked out for EXCAVATION, EARTH WORK AND SITE CLEARANCE as listed in Sch A Part II 4 Lump sum price worked out for INTERNAL ELECTRIFICATION as listed in Sch A Part III 5 Lump sum price worked out for INTERNAL WATER SUPPLY as listed in Sch A Part IV 6 Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch A Part V 7 Lump sum price worked out for AREA DRAINAGE as listed in Sch A Part VI 8 Lump sum price worked out for ROAD/ PATH as listed in Sch A Part VII 9 Lump sum price worked out for FENCING/GATE as listed in Sch A Part VIII 10 Lump sum price worked out for EXTERNAL ELECTRIFICATION/STP as listed in Sch A Part IX 11 Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch A Part X 12 Lump sum price worked out forRAIN WATER HARVESTING as listed in Sch A Part XI 13 Lump sum price worked out for HOT WATER SUPPLY as listed in Sch A Part XII 14 SCHEDULE A PART - XIII MISCELLANEOUS ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signifies this fact only. Bidder shall insert their rates in Green filed under Col-6. 15 SITE CLERANCE & DEVELOPMENT 16 M & L for Surface excavation n.exc30 cm deep and averaging 20cm deep and getting out top layer arqanie soil without disturbing or destroy its texture and remove the same to a location specified and stored properly for relaying after the completion of building work exc 50m but n exc 250m complete all as specified and as directed 17 Relaying the soil excavated in Item no 13 to building site for landscaping and gardening complete all as specified and directed 18 S&F colour coaded plastic dustbins of 120 Litre capacity each in Green/Blue/Red in colour as directed by GE , made of high grade UV resistant polyethylene, suitable for segregation of biodegradable, recyclable, hazardous and sanitary waste bins to be durable , Light weight, weatherproof, easy to clean with tight fitting lids and clear identification lables complete all as specified and directed..Note :-Labelling on dustbin are as follows:a) Green color waste bin :- Bio degradable wasteb) Blue color waste bin :- Reusable/ Recycle waste c)Red color waste bin :- Land Fill waste 19 INTERNAL ELECTRIFICATION 20 S & F for wall mounted LED box type tube light fitting 4 x 20 watts industrial commercial interior batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouputboxtype fitting, 230 volts and intregrated electronic driverconnector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. 21 S & F forLED tube light fitting with aluminium housing 2 feet x 10 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cableof suitable sizefrom ceiling rose to fittingwith warranty option of 5 years from date of installationcomplete all as specified and as directed. 22 S & F forLED tube light fitting with aluminium housing 2 feet x 5 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cableof suitable sizefrom ceiling rose to fittingwith warranty option of 5 years from date of installationcomplete all as specified and as directed. 23 S & F for Decorative wall mounted luminaire made out of Nickle finesh square base with bend pipewith unbreakable globe glass suitable for LED bulb and provosion of LED bulb 10 watts complete all as specified and as directed. 24 S & F for ceiling fan, 230 Volts, 1200 mm sweep with mian air delivary 210 CFM, service value of the fan shall be greater than 6.1 (5 star rated) as per BIS with blades, down rod & other necessary accessories with brushless direct current motor (BLDC)with remote system and electrical connections from ceiling rose to fan teriminal complete all as specified and directed. 25 S & F for energy efficient exhaust fan of 225 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existing wall for fan base compelte all as specifiedand directed.(Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be includedin overall rate quoted). 26 S & F for energy efficient exhaust fan of 300 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existingwall for fan base compelte all as specifiedand directed.(Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be includedin overall rate quoted). 27 Supply, installation, commissioning and testing indoor type LT wall mounting Bldg panel board of suitable sizefactory made TTA panel, weather, dust & vermin proof indoor, double door, front openable, locking arrangements made out of 2.00 mm thick mild steel CRCA sheet including required comparment for fixing of four (12) Nos single phase smartmeter, MCCB and MCB and porviding glass view for reading of meter and providing rubber/ PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/ sleeves with maintained the colour code and copper strip/ wire busbar of suitable size to MCCB input and MCCB/ MCB output of suitable length for connection of cable from main busbar, angle iron 50 mm x 50 mm x 5 mm thick supporting frame including applying two coats of powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfacesfor 3 phase 4 wire system 415/ 440 volts grade including internal wiring connections for all outgoing / incomming cable,earthing teminals , danger plate, suitable PCC platform complete all as specified and directed 28 INCOMING(a) Copper strip busbar of suiable of capacity 200 Amps rating wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos.(b)MCCBIP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 100 Amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links -01 No.(c) Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch – 01 No(d)LED Neon indicator lamp (RYB) with holder,230/250 volts,AC -01 set (set of three) Make :- AE/L&TOUTGOING(a) MCB, Single pole & neutral, 40 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 12 Nos (Officers Accn)(b) MCB, single pole & neutral, 10 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 1 No (Stair case lighting)(c) Slot for fixing the three phase smart prepaid meter - 13 Nos (Cost of Smart meter cost will be paid seperately under respective itemly) 29 Supply, installation, commissioning and testing indoor type LT wall mounting Bldg panel board of suitable sizefactory made TTA panel, weather, dust & vermin proof indoor, double door, front openable, locking arrangements made out of 2.00 mm thick mild steel CRCA sheet including required comparment for fixing of four (07) Nos single phase smartmeter, MCCB and MCB and porviding glass view for reading of meter and providing rubber/ PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/ sleeves with maintained the colour code and copper strip/ wire busbar of suitable size to MCCB input and MCCB/ MCB output of suitable length for connection of cable from main busbar, angle iron 50 mm x 50 mm x 5 mm thick supporting frame including applying two coats of powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfacesfor 3 phase 4 wire system 415/ 440 volts grade including internal wiring connections for all outgoing / incomming cable,earthing teminals , danger plate, suitable PCC platform complete all as directed 30 INCOMING(a) Copper strip busbar of suiable of capacity 120 Amps rating wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos.(b)MCCBIP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 63 Amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links -01 No.(c) Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch – 01 No(d)LED Neon indicator lamp (RYB) with holder,230/250 volts,AC -01 set (set of three) Make :- AE/L&TOUTGOING(a) MCB, Single pole & neutral, 40 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 06 Nos (Officers Accn)(b) MCB, single pole & neutral, 10 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 1 No (Stair case lighting)(c) Slot for fixing the three phase smart prepaid meter - 07 Nos (Cost of Smart meter cost will be paid seperately under respective itemly) 31 M & L for maintenance free Chemical earthing of technology with copper bonded steel rod 3 mtr long 25.0 mm dia with 250-micron Copper bonded coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 holes of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material- polymer body & cover dimensions- 308 mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed. 32 Note:-(i) Earthing is to be done infront of the Engr-in-Charge.(ii)Test Results of earthing to be submitted by the contractor for all earthings.(iii)The Contractor shall have to give written guarantee for maintenance earth resistance of less than 1.0 Ohm for the period of 10 9ten) years after certified date of completion and shall bdeposited 2000/- per earthing as security deposit for a period of Ten (10) Years.(iv)Failing to maintain resistance of earthing less than 01.0 ohm , new earthing to be provided by the contractor with out any extra cost.(v)Necessary earth work, excavation shall be carried out in any type of soil strata, retuning, filling in and making good surronding area complete. 33 Supply and Installation of Smart Single Phase Meter of different makes (Not more than 33 % of a particular make) including polycarbonate boxes with transparent cover to view meter display with the following specifications:(a) AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 5A-60A, with 3200 impulses per KWh,LED forPhase presence & LED for Relay status, conforming to IS-16444 standard with inbuilt 865-867 MHz 6 Low PAN Mesh Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LCD based display only with compatible IP54 compliant polycarbonate box for outdoor mounting with optical port Provision on meter box. Meter Should support the following data : 15/30 min instantaneous data for Voltage, Current, Power factor, Power, Cumulative energy and frequency, monthly billing data & antitamper features. Load survey data for 45 days with 30 min integration period for kWh, Voltage, Current, frequency etc.Meter should have connect / disconnect functionality operable from prepaid billing software & shall show balance on displayThe meter should support open communication protocol DLMSwith the softwareNote :-(a) It should run the meter in both prepaid and postpaid mode(b) The meters should carry 5 year warranty.(c) OEM shall have own NABL accredited lab for testing meters as per IS 16444 and certification shall be provided during sample approval(d) The meter cost would include DCU/ Gateway and repeater cost for RF commuication meters 34 Supplying, Fixing, Commissioning and testing of configuration of cloud based prepaid software forwith following modules: (i) Meter Data Management Module: The meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. The system would support offline meter data entry.The meter data management system would capture and provide the following data:(a) 30min instantaneous data from all the meters for seven parameters- Cumulative Energy,Power, Current, Voltage, Power factor and Frequency.b) Monthly and quarterly billing survey data for cumulative energy and max demand, Load Survey Data, Tamper Events(ii) Communication module: The system should provide communication of energy data and bills via print, email.(iii) Meter Master Data : The system would support meter data repository. The system should support meter replacment process.(iv) Excel Export : The system would support export of metering and billing data in excel formatNote:- (i). Software will be compatible with all makes of smart meter & shall be CERT-IN certified from CERT approved vendors for any cyber security related threat & complying as per ENC guidelines.(ii) It shall also include recurring SMS charges, Email gateway integration charges, payment gateway charges for online meter recharge etc & shall be included in quoted rate for 2 years DLP period.(iii) Provision for comprehensive operation including periodic charges of telecom operator, smart meter billing from completion of work till the competion of defect liability period of 2 years.(iv) The software would be hosted on MEITY GCC approved server. 2 years hosting costs would be included. 35 INTERNAL WATER SUPPLY 36 S & Fchromium plated fancy type Angle cock with wall flange quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 37 S & FChromium plated fancy type two way Angle cock with wall flange quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 38 S & FChromium plated fancy type Bib cock with Aerator quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 39 S & FChromium plated fancy type Pillar cock with Aerator quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 40 S & FChromium plated fancy type Sink cock(wall mounted) with Aerator long shunk quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 41 S & F Chromium plated fancy type Wall Mixer 3 In 1 (flow rate 6 liter per minute) with flange Provision For Overhead Shower with 115mm Long Bend Pipe On Upper Side, Connecting Legs & Wall Flangescomplete all as specified and directed.Make - Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 42 SEWAGE DISPOSAL 43 Supply, laying and testing of 150mm internal diameter of double wall corrugated (DWC) high density polythylene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked(with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS 16098-2013 Part-2 complete all as specified and as directed. Note : Bedding of pipe shallbe provide as per theconstruction methods ,andshall be strictly compiled as per clause No A-4 of Annex A of IS 16098 Part II 44 Supply, laying and testing of 200mm internal diameter of double wall corrugated (DWC) high density polythylene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked(with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS 16098-2013 Part-2 complete all as specified and as directed. Note : Bedding of pipe shallbe provide as per theconstruction methods ,andshall be strictly compiled as per clause No A-4 of Annex A of IS 16098 Part II 45 SEWAGE TREATMENT PLANT(STP) 46 Supplying, Design , Construction, Hydraulic testing , Commissioning and giving satisfactory trialsSTP of capacity 10KLD consisting of PMF Technology based along with the following accessories to the desired capacity of 10 KLD rated net outputcomplete as turnkey jobwith all involved electrical and mechanical componentsfor satisfactory performance of plant andrequired treated outlet waterparameters as per E-in-Cs Br Policy No 05/ 2023 dated 04 May 2023 complete all as specified and directed(a) Construction RCC tanks of following sizes:-(i) Septic tank of size - 3.70 Mtr x 1.80 Mtr x 1.50 Mtr - 01 No(ii) PMF tank of size - 4.20 Mtr x 2.80 Mtr X 1.20 Mtr- 01 No(iii) Filter Feed tank of size- 1.70 Mtr x 0.80 Mtr x 1.50 Mtr - 01 No(iv)Treated Water tank of size- 1.70 Mtr x 0.80 Mtr x 1.50 Mtr - 01 No(v)Chamber between PMF & FFT of size- 0.45 Mtr x 0.45 Mtr x 0.45 Mtr - 01 No(vi) Manhole Chanber made out of brick work im CM 1:6 suitable size with FRP Manhole Covers of size - (600 mm x 600 mm) - 05 Nos 47 (b) Supply & laying of Stone course aggregate of following sizes:-(i) 8 size (200 mm) - 2.60 Cu mtr(ii)4 size (100 mm)- 2.60 Cu mtr(iii)2 size (50 mm) -2.60 Cu mtr(iv)Coarse Sand - 2.60 Cu mtr(c) Supply & laying of Bacterial Culture ( suitable for degrading sewage-1200.00 KG(d) Supply & plantingof saplings Canna Indica - 60 Nos(e) S & F for Non-clog submersible Raw sewege Pump, Single phase, 230 Volts, 50 Hz of discharge capacity 0.63 cum/ Hr @ 10 Mtr head complete- 02 Nos (01 W+ 01 S) (f) S & F for Submersible opern well pump set, Single phase, 230 Volts, 50 Hz for fresh treated water application discharge capacity 0.63 cum/ Hr@ 25 mtr head complete- 02 Nos (01 W+ 01 S) (g) Supply and install for heavy duty chemical dosing system plunger type suitable to injet solution with suitable capacity, working pressure10 Kg/cm2, comprising dosing pump coupled with 3 phase electric motor of suitable capacity, 1440 rpm assembly with Agitator in one motor , Agitator with stainless steel sweepblade duly FRP coated, FRP tank suitable capacity, complete unit mounted on heavy duty MS fabricated frame duly anti corrosive paint complete with chemical grade PVC NRV along with control panel for dosing pump suitable made of power coated MS fabricated box consting of LED indicater, digital Voltmeter, single phase preventor, high voltage, low voltage protection complete - 01 Job 48 (h) S & F for of PSF (Pressure sand filter) of size 250 mmin dia and height 1.30 mtr made out of FRP material suitable for withstand of 2.50 kg/cm2 pressure with multi port valve and interlinking piping - 1 Job(j) S & F for for ACF (Activated Carbon Filter) ofsize 250 mmin dia and height 1.30 mtr made out of FRP material suitable for withstand of 2.50 kg/cm2 pressure with with multi port valve and interlinking piping - 01 Job(k) S & F for UPVC Pipe of sizes 25 mm dia & 40 mm dia suitable with stand the pressure 6 kg/cm2 as required- 01 Job(l) S & F for copper conductor multistranded 3 core cable PVC insulated sheathed calble of size 2.5 Sqmm for motor connections from starter panel to motor control connector as required- 01 JobNote:-Components/ units/ Equipment/ accessory for PMF Technology based STP is as perdesign and indicative . However OEM can add/ alter/ omit the given components as per their design to achieve desired capacity and treated outlet water parameter with same technology as per E - in- Cs Branch New Dehli guidelines/ policies . 49 Supplying, Design, Construction, Hydraulic testing , Commissioning and giving satisfactory trials for Chop Whoop Winding Process MBBR/ JOHKASOU based FRP Underground Package STP along with the following accessories to the desired capacity of 30 KLD rated net output, complete as turnkey job with all involved electrical and mechanical components complete all as specified and directed for satisfactory performance of plant and required treated outlet water parametersas per E-in-Cs Br Policy No 05/ 2023 dated 04 May 2023Note:- The STP shall be designed based on the inlet & outlet parameters of E-in-Cs Branch above policy.(a)Chop Whoop Winding Process MBBR/ JOHKASOU based FRP Underground Package STP inclusive of Solid Separation, Anoxic Zone, MBBR Aeration Zone & Final Sedimentation zone Tank of size 8440 mm (L) x 2430 mm (dia) Tank- 01 No(b)Chop Whoop Winding Process based FRP Underground Intermediate Water Storage Tank 10 KL of size 4310 mm (L) X 1830 mm (dia) Tank- 02 Nos(c) With socket provision on tanks as per the design of UPVC return sludge pipe 50mm dia, PVC inlet outlet pipe 150mm dia, PVC interconnection pipe of 150mm dia, UPVC 80 mm dia, FRP Straps, Turn Buckle Wire Rope, Concrete Deadman & Eye Bolts per the diameter & length of the tank, Manhole cover as per the drawing, PVC air vent nozzle of dia 50mm, manhole cover of size 550mm dia, etc- 01 Job.(d) S & F for On-Ground LLDPE Treated Water Storage Tank of 10 KL Capacity of size2550 mm dia x 2510 Height- 01 No(e)Supply installation, testing and commissioning of cubical type Relay Based Control Panel out door type madeout of 3.15 mm thick CRCA sheetof suitable size suitable for 415V, 3 Phase, 4 wire, 50 Hz AC with necessary MCCB for incoming , copper busbar, MCB for out going & necessary DOL stater etc- 01 Job 50 (f)Twin lobe rotary Air compressor capable of delivery 56 Cum /Hr suitable volume of free air at 0.27 - 0.37 kg/sq.cm, discharge Pressure 0.2 - 0.3 kg/cm2g, Noise Level at 1.5 m distance: <70-80 (DBA),Body rotter made out of EN19 with FG260 & FG-260(CI), Silencer Fabricated with MS material.driven through V belt or directly coupled though flexible coupling to a TEFC motor of suitable capacity 1440 RPM, 415 Volts, 3 Phase,50 Hz, Pressure guages-01 No,150 mm NRV -01 No, Butterfly shut off valve, air filter, cleaner etc including 3 core copper cable multistranded connection of suitable size from starter to air compressor assembly complete all as specified and directed. 02 Nos (1W + 1S)(i)UPVC pipes 80 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing works complete all as specified- 01 Job(g) Sludge Recycling Pumpof non clog submersible sewage pump set suitable to handle domestic sewage water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set suitable with Flow Rate 9.0 m3/hr, Head 10 Mtr (1.0 HP) for operation at 415Volts frequency 50Hz, 3 Phase- 01 No (1W) (For Sludge recycling in Solid Separation zone)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor type shall be a squirrel cage induction motor with F class insulation. (ii)UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrangements complete all as specified- 01 Job(h) Pressure Sand Filter Capacity 3.0 cum/hr made out ofFRPSide Mounted of Size: 21 x 62,workingPressure 10 PSI, Filter Media, Pebbles & Filtering Sand, PVC Piping 50 mm Size (UPVC), Multiport Valve (Manual)-01 Job 51 (j)Activated Carbon Filter Capacity: 3.0 cum/hr, made out ofFRPSide Mounted of Size: 21 x 62, workingPressure 10 PSI, Filter Media: Activated Carbon 900 - 1100I/V,PVC Piping 50 mm Size (UPVC), Multiport Valve (Manual)-01 Job(k)Chlorine (Sodium Hypochlorite) Dosing Pump of Capacity 0-6 LPH, PTFE Diaphragm, single phase 230 Volts, 50 Hz including with HDPE Chlorine Dosing Drum of Capacity 100 Ltrs and necessary connections etc- 01 Job(l) Filter feed pump of non clog submersible sewage pump set suitable to handle domestic sewage water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set with Flow Rate 3.0 m3/hr, Head 15-20Mtr (1.0 HP), suitable for operation at 415 Volts, 50Hz , 3 Phase- 02 Nos (1W+1S) (For pumping into PSF & ACF Filters)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor type shall be a squirrel cage induction motor with F class insulation. (ii) UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrangementscomplete all as specified- 01 Job(m)Raw sewage Water transfer Pump of non clog submersible sewage pump set suitable to handle domestic sewage water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set with Flow Rate 9.0 m3/hr, Head 10-15 Mtr (1.0 HP) suitable for operation at 415 Volts, 50Hz , 3 Phase- 02 Nos (1W+1S) (For pumping from Raw Sewage Collection tank into the Bar Screen Chamber)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor (k) Ctype shall be a squirrel cage induction motor with F class insulation. (ii)UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrandements complete all as specified- 01 Job 52 (n) Treated Water transfer Pump of Monoblock pump set suitable to handle domestic treated water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set with Flow Rate 9.0 m3/hr, Head 10-15 Mtr (1.0 HP) suitable for operation at 415 Volts, 50Hz , 3 Phase (1W+1S) (For pumping from treated water zone to reuse)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor type shall be a squirrel cage induction motor with F class insulation. (ii)UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrandements complete all as specified- 01 Job(o) Fine bar Screen with chamber (manual) of SS 304 for screening 5 to 6 mm particles of size 1.0 Mtr x 1.0 Mtr at inlet of MBBR tank- 01 Job 53 Note : - (i)The Package STP tank shall be made from 100% FRP Material through Chop Whoop Winding Process with compliance and certification/approval in UL 1316 from the UL LLC that is Underwriters Laboratories LLC.(ii)The FRP tanks shall be made using Isopthalic Unsaturated Polyester Resin.(iii) The Sewage Treatment Plant system shall have a valid certificate of a Green product from a reputed Government or Third party having authority to certify like CII, IGBC, Assocham or any other body having competence in issuing such certificates.(iv)The shell thickness of the tank shall be between 6.50 mm to 7.50 mm (±0.5 mm) & Dish end thickness must be 11 mm and above made only from 100% FRP material(v)Technology must be empanelled in CPHEEO Sewage Manual.(vi)Minimum Hydraulic Retention time of the total Package STP system/tank must be 22.00 hours.(vii)Minimum sludge handling should only be once a year(viii)STP must function from minimum load of 5 - 10% to 100%. (Minimum load to Peak Load)(ix)The STP must have an anoxic zone for denitrifuication(x)Minimum volume of Intermediate Water Storage tank in FRP MOC must be 10 KL(xi)Minimum volume of Treated Water Storage tank in LLDPE MOC must be 10 KL 54 Material and Labour for Motor ControlLT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. Motor Control LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) complete including the following accessories:-. 55 IN COMING:-(i)Copper strip busbar of 60 Amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos(ii) On load change over Switch TPN of capacity 32Amps - 01 No (iii) 4 Pole MCB of capacity 5-32 Amps 10 KA breaking capacity C curve-01 No(iv)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three) (v)Digital Multifunctional meter , flush mounting type with CT’sand selector switch – 01 set.OUT GOING :-(b) MCB SPN 5-32 Amps 10 KA breaking capacity C curve-04 Nos(c) DOL starter single phase with suitable relay range conforming to IS -1347(Part IV) suitable for discharge capacity 6.4 LPM ( 0.38 Cumt/Hr)at 10/25 Mtr head, 0.50 HP, including overload relay, auto timer, indicating lamps (LED) etc complete -04 Nos 56 Supply and laying fordouble wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 (Part I and II) for protection of underground cables of size nominal outer dia 63 mm & nominal inner dia 50 mm dia with all fittings laid in trenches / road/ nallah or fixed along wall for cable protection all as specified. 57 HOT WATER SUPPLY 58 Supply and installation,commissioning and testing at roof top of building Solar water heating system (Flate Plate Collector) based on indirect transfer of heat of capacity 100Ltr per day with electrical back up of 2 KWas per manufacturers recommednations includinghot water storage tank of capacity 300 ltrs and of 20 guage thickness stainless steel plate (having insulation of rock wool ) mineral wool 100 mm thick & cladding with aluminium sheet 24 SWG complete all as specified and directed. 59 ROAD/ PATH 60 Material and labour for providing and painting 2.5 mm thick road marking strip (retro reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser,propane tank heater and profile shoe heater, driven by experienced operator on road surace including all cost of material, labour, T&P, cleaning of road surface of dirt, seals, ils, grease and foreign material etc. complete all as specified and directed. 61 EXTERNAL ELECTRIFICATION 62 Supply and fixingfor Cable route indicator / Marker made up of PCC Block in cement mortar 1:3:6 ( 20 mm graded aggregrate ) of size 900 x 300x 100 mm thick with DANGER/ 11 KV CABLE/ MES embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work ( as required / ordered at site) complete all as specified and as directed. 63 S upply and fixingfor Cable route indicator / Marker made up of PCC Block in cement mortar 1:3:6 (20 mm graded aggregrate) of size 900 x 300x 100 mm thick with DANGER/ LT 433 VOLTS CABLE/ MES embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work (as required/ ordered at site) complete all as specified and as directed. 64 Supply, installation, Testing and commissioning of Outdoor type (IP 54), 03 way RMU (Ring Main Unit) 11 KV, 630 Amps, 21kA-3 Sec,IP54 SF6 insulated, One side Extensible,consisting of One No (01) motorised vacuum circuit breaker (Incomer) and Twor Nos (02) motorised vacuum circuit breaker (Outgoing) & Metering Panel Bus PT with Top LV, Battery & Battery charger, Ethernet switch & LIU (Configuration VVV+M), inside robotically welded stainless steel 304 (Non Ferrite non Magnetic Grade) tank having min thickness 2.5 +/- 0.5mm with IP 67 degree of protection and enhanced BIL of 75 kVp internally to manager voltage surges and Air Insulated Metering Module of Class-0.5. RMU should be provided with internal busbars, as well as earthing busbars of electrolytic grade copper, padlock provisions & complete with all accessories. The complete RMU must be type tested for Internal arc21KA for 1 sec with AFLR Classification for Gas tank & Cable Chamber as per IEC 62271-200. HT RMU shall preferably have on-site-repairability features such as site replaceable bushing/ coupling/ mechanism and gas refilling to have very less downtime in the event of bushing breakage and restoration can be done at site immediately without sending the RMU to OEM Works, the Vaccum Interrupter must RMU manufacturers own make. The earthing busbar shall be provided inside each cable compartment for solid earthing of cable shields. The outer hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protectioncomplete all as specified and as directed. The unit shall include the following with all necessary standard fitting as required at site.-Make of RMU shall be limited to : ABB/ SIEMENS/ SCHNEIDER INFRASTRUCTURE(Channel partner/ System Integrator/ Authourized Partner/ License partner make RMU shall not be accepted.) 65 (a) Vacuum Circuit Breaker consist of following accessories :-(i)Microprocessor based Numerical Protection Relay for Circuit Breakers - REF615, Feeder Protection and Control Relay, Protections 50, 51, 50N, 51N, 46, 49, 67, 67N, 32, 27, 59, 25, 81U, 81O, 95 Measurement for 3I,I0,3U,U0,Kw,KVA,PF,Hz,Kwh, 16 DI + 10 DO, One front RJ45 Port, One Rear RJ45 Port for IEC-61850 Protocol, Drawout Type with CT Shorting feature, Graphical LCD Display(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator on the gas tank.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO amd suitable for 10,000 mechanical operation.(v)CT shall be minimum 50-100/1A ,2.5VA , 5P10 - 3 Nos. for protection(vi)CT shall be minimum 50-100/1A ,2.5VA , Class 0.5 - 3 Nos. for metering(vii)Right angle boot to be provided in each module(viii)2 x12 Volts, 26 AH Battary with Charger - 1 Set(ix)Bus VT shall be 11KV/V3/110V/V3 ,20VA , Class 0.5 - 3 Nos. for metering(x)Auxiliary VT shall be 11KV/230 ,500VA for AC supply input to Battary Charger.(xi)Capacitive voltage indication fixed type system as per IE(xii)Interlocked Cable box for front termination of the cable suitable upto 3 core 120 Sqmm,11 KV XLPE cable (IP3X). Safety interlocked to prevent access to cable termination in live-condition. 66 (xiii)Right angle boots (push on type)(xiv)Cable covers with self Interlocking mechanism between doors, earth switch, disconnector & VCB.(xv)Necessay interclocking arrangement for safety and operations(xvi)One No. Operationg Handle for Manual Operation and one no. manometer(xvii)Safety Interlocks Shall be provided as per relevant IEC/IS Standards and Manufacturers directions.(xviii)Above switchgear shall confirm to all relevant IEC/IS Standards. 67 Supply, installation, commissioning and testing of transformer of capacity 315 KVA, confirming to IS 1180 (Part-1)- 2014 with latest amendment No 4, BEE 3 star rated, EEL 3, step down Outdoor type complete with standard fittings, HT 11 KV 3 phase LT 433 vols, 3 phase, 4 wire corrugated 7 position off circuit tape links of rating + 7.5 to -7.5% @ 2.5% by means of hand operated off load tap changer including necessary control wiringtransformer copper wound, double wound, oil immersed naturally cooled with external cooling tubes core type delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector symbol Dyn -11 (vector group with neutral brought on secondary side (LV side) and the maximum temperature rises should not exceed 40 degree centigrade in oil and 45 degree centigrade in HV/LV winding ring measured by resistance after continuous full load run in ambient temp as per IS -2026 per transformer, IS-3639 for fitting & accessories, IS-2099 for high voltage porcelain bushings and the transformer shall be comprised with the following standard fitting with on load tappings on HT side to vary secondary voltage within limit all as per IS -1180 complete all as specified and as directed wit latest policy for following:- 68 Note 01:- (i)Three Nos porcelain bushing suitable for 11 KV on HV side, complete with copper rods, nuts and washers with cable end box.(ii)Four Nos porcelain bushing suitable for 433V on LV side, complete with copper rods, nuts and washers with cable end box.(iii)Monogram plate.(iv)Oil conservator with filter and drain plug.(v)Prismatic/transparent oil gauge.(vi)De-hydrating breather with first fill of dehydrating agent (silica gel).(vii)Thermometer pocket.(viii)Air release plug.(ix) Inspection cover(x) Lifting lugs for complete transformer(xi)Top cover lifting lugs(xii) Jacking lugs(xiii) Top filter valve(xiv)Instruction plate(xv)Drain cum bottom filter valves(xvi)Earthing terminal and stud(xvii)Off load tap changer (xviii)Rating and Diagram plate(xix) Buchholz relay with alarm & trip contacts.(xx)Bi directional roller wheel -04 Nos. 69 (xxi)Marshalling box for termination of all alarm & trip controls of the transformer.(xxii)WTI (Winding temperature indicator) with alarm & trip contact(xxiii)Oil surge relay.(xxiv)Shut off valve for buchholz relay.(xxv) OTI (Oil temperature indicator) dial type of 150 mm with alarm and trip contact capillary type.(xxvi)Two earthing terminals on tank cover to facilitate fixing of 50x6 mm galvanised iron earth strip for earthing of body.(xxvii) Necessary PCC foundation/ block masonry platform as directed by OEM. (xxviii)First filling of new and unused transformer oil, IS-335 marked.Note 02 :- (a)The rates include for supplying transformers with standard fittings and installing complete including all jointing materials, connecting with electrical system, earthing, testing and commissioning. (b) The transformer will have its initial oil filling to appropriate level (cost of oil including testing with desired dielectric strength included in supplied and installed rates, cost of PCC foundation shall be included as per manufacturer drawing) 70 Supply, fixing, installing and commissioning of octagonal Galvanised street light pole 9 mtr long, top dia 70 mm, bottom dia 155 mm, sheet thickness 3 mm and base plate dimensions 260 x 260 x16 mm thickness with door locking arrangement for provision ofterminal plate consisting ofMCB TPN 10 Amps, with necessary electrical connections including 04 Nos foundation with J type foundation bolts -04 Nos of sizeas per manufacturer design should be hot dipped galvanized andGI single arm bracket (Ornamental type) complete with door locking arrangement complete all as specified and directed.Note:- Necessary Excavation of Soil, RCC foundation as per manufacture recommendation including foundation bolts etc deemed to be included in quoted rate. 71 Supply ,fabrication, installation and testing of LT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) .All extension link/ inter connection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:- (Transformer main LT Panel) 72 Note:- Rate of earthwork and PCC work etc are deemed to be inclusive in this item.IN COMING:a)Copper strip busbar of 1000 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nosb)4 pole MCCB 500 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.(c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider.(d)Digital Ammeter of range (0- 250) Amps, flush mounting type with CT’s of ratio 250/5 and selector switch – 01 set.(e)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. 73 OUTGOING:- (a)4 Pole MCCB 125 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No (MWO/ WO accn Bldg Panel No 1)(b)4 Pole MCCB 160 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 04 Nos (for Sgt Accn Panel No 2, 3, APFC panel & Spare)(c)4 Pole MCCB 32 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No(d)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter - 01 No. 74 Supply ,fabrication, installation and testing of LT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) .All extension link/ inter connection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:- (forMWO/WO Accn LT Bldg Panel No1)Note:- Rate of earthwork and PCC work etc are deemed to be inclusive in this item. 75 IN COMING:-a)Copper strip busbar of 250 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nosb)4 pole MCCB 125 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.(c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider.(d)Digital Ammeter of range (0- 250) Amps, flush mounting type with CT’s of ratio 250/5 and selector switch – 01 set.(e)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. 76 OUTGOING:- (a)4 Pole MCCB 63 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 03 Nos (forMWO accn Bldg supply- 2 Nos & Spare)(b)4 Pole MCCB 32 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 01 No (Street light)(c) Multifunctional Digial type Astronomical function Time switch (Astro type having longitude and latitude of Indian cities memory) 240 volts AC Single Phase - 01 No(d) Power contractor 4 Pole, 32 Amps,415 Volts, 50 Hz - 01 No (e)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter - 01 No. 77 Supply ,fabrication, installation and testing of LT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) .All extension link/ inter connection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:-(for Sgt accn Bldg Panel No 2 & 3) 78 Note:- Rate of earthwork and PCC work etc are deemed to be inclusive in this item.IN COMING:- a)Copper strip busbar of 400 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nosb)4 pole MCCB 160 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.(c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider.(d)Digital Ammeter of range (0- 250) Amps, flush mounting type with CT’s of ratio 250/5 and selector switch – 01 set.(e)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. 79 OUTGOING:- (a)4 Pole MCCB 100 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 03 Nos ( Sgt Accn bldg supply- 02 Nos & Spare)(b)4 Pole MCCB 32 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 01 No(e)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter - 01 No. 80 Material and labourfor Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure for cable protection and making good as existing complete all as specified and as directed. 81 Material and labourfor maintenance free Chemical earthing of technology 3 mtr long20 mm dia with 250-micron Copper coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 holes of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material- polymer body & cover dimensions- 308 mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed. 82 Note:- (i) Earthing is to be done infront of the Engr-in-Charge.(ii)Test Results of earthing to be submitted by the contractor for all earthings.(iii)The Contractor shall have to give written guarantee for maintenance earth resistance of less than 1.0 Ohm for the period of 10 9ten) years after certified date of completion and shall bdeposited 2000/- per earthing as security deposit for a period of Ten (10) Years.(iv)Failing to maintain resistance of earthing less than 1.0 ohm , new earthing to be provided by the contractor with out any extra cost.(v)Necessary earth work, excavation shall be carried out in any type of soil strata, retuning, filling in and making good surronding area complete. 83 EXTERNAL WATER SUPPLY 84 Supply, Laying, jointing & testing of 150mm dia (6) Ductile iron (DI), pressure pipes with spigot and socket ends, centrifugally cast, class K-7, with cement mortar lining in inner side as per IS:8329/ 2000 (latest revision) and other relevant standards and metallic zinc coating followed by a finishing layer ofepoxy paint in outer side,suitable for push on joint(rubber gasket joint) including rubber gasket in any length with inside cement mortar lining laid in trenches/ over masonry pillarcomplete all as specified and as directed 85 Supply, Laying, jointing & testing of 100mm dia (4) Ductile iron (DI), pressure pipes with spigot and socket ends, centrifugally cast, class K-7, with cement mortar lining in inner side as per IS:8329/ 2000 (latest revision) and other relevant standards and metallic zinc coating followed by a finishing layer ofepoxy paint in outer side,suitable for push on joint(rubber gasket joint) including rubber gasket in any length with inside cement mortar lining laid in trenches/ over masonry pillarcomplete all as specified and as directed.Notes foraboveItems No 53 & 54 :- (i) Excavation & Earthwork, shall be measured and paid separately. (ii) The necessary Exise duty exemption certificate from Deputy Commissioner of respective district shall be arranged by the GE for DI pipe.The contractor shall quote the rates against these items considering Exise exemption. (iii) The quoted rate shall also be deemed to include for provision of joints and jointing material for laying pipes. For jointing ofpipe fittings or taking branch connection, provision of joints and jointing material shall be measured and paid separately. (iv) . Before laying of pipe line contractor has to submit layout diagram as per level difference and ensure proper alignment of the pipe. 86 Material and Labour for Ductile iron fitting for spigot socket pipe such as bends (any type, radius and angle) tapers any type (straight, bend increasing, decreasing or double socket etc). Tee pieces single branch. Y junction, double branch, cross (All socket or socket and spigot) collars, restrained joint, mechanical joint, caps & plugs 80 mm to 250 mm dia bore including cutting and jointing new positions complete all as specified and as directed 87 Material and Labour forcutting CI pipes 150 / 80mm in position for insertion and including provision of Tee branches etcfor 80/50 mm dia pipe line complete all as specified and directed 88 Material and labour for construction of brick masonry valve pit of internal size 90cm x 90cm x 90cm suitable for gate valves/ sluice valve upto 150 mm including necessary excavation and earth work, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 50mmx50mmx6mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock complete all as specified and directed.Note:- (i) Brick wall shall be 23 cm thick built in cement mortar (1:6)(ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450 mm from top shall be 20 mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds(iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls (iv) PCC coping shall be 15 cm thick in cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC(v) Three coats of white wash to internal surfaces of valve pit shall be provided(vi) Depth of valve pit shall be reckoned from the top of PCC in foundation 89 Material and labour for construction of brick masonry valve pit of internal size 60cm x 60cm x 70cm suitable for gate valves/ sluice valve upto 150 mm including necessary excavation and earth work, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock complete all as specified and directed.Note:- (i) Brick wall shall be 23 cm thick built in cement mortar (1:6)(ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450 mm from top shall be 20 mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds(iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls (iv) PCC coping shall be 15 cm thick in cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC(v) Three coats of white wash to internal surfaces of valve pit shall be provided(vi) Depth of valve pit shall be reckoned from the top of PCC in foundation 90 RAIN WATER HARVESTING 91 Supply and Fixing 150mm bore PVC slotted pipes double socketed in any length with suitable joints, laid in bore hole for recharge pit and like complete all as specified and directed 92 Boring 300mm dia for Bored cast in situ piles 16 metres in any kind of soil/soft rock and getting out and disposal of spoil to a distance 50 metres using suitable method complete all as specified and directed 93 FIRE FIGHTING SYSTEM 94 Supply and Fixing for 3 kg light-weight squeeze grip CO2 type fire extinguisher, conforming to IS 15683: 2006, with CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed Make: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 95 Supply and Fixing for 5 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directedMake: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 96 Supply and Fixing for 9 litre mechanical foam type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted with gunmetal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directedMake: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 97 Supply and Fixing for 9 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directedMake: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 98 Supply and Fixing for Galvanized mild steel Fire bucket (Filled with dry sand & water) conforming to IS 2546: 1974 round bottom type enamel painted, white inside & Red out side and Letter FIRE in black out side and handle with mounting bracket complete as specified and directed 99 Supply and Fixing for Galvanized mild steel Fire hook bracket with 3 mtr bamboo handle painted with red colourcomplete as specified and directed 100 Supply and Fixing for Galvanized mild steel Fire Beater bracket with 3 mtr bamboo handle painted with red colourcomplete as specified and directed
Contract Date: Mar 11, 2026 Contract Value : 14.98 Crore
Statutory Bodies & Commissions/Committees No of Bidders 5
47.
Housing Urban and Rular Development #9691074 Technical Bid
Providing Furniture And Water Cooler At Sabhagruha, Yatri Nivas, International Library, Visitor Facility Centre, Parking Lot, Anna Sagar Lake, Dam River Area And Eco Forest Under Sevagram Development Plan Sevagram Wardha-Item No. 01 Providing And Supplying Standing Floor Lamp With Holder, Shade Ring And On -Off Switch Base Fixture Material To Be In Metal. Height Of The Lamp To Be Range From 4-5 To 5 Approximately Etc Complete Item No. 02 Providing And Fixing Mirrors In Bathroom Size 1500L x 1000H With 75 X 75mm Teakwood Framing, and Structure in 12mm Thick Bwr Plywood (Make century, Commander, city ply, Sharen, Euro Gold, Biz etc. or Equivalent Make) All Exposed & Unexposed Surfaces Covered Back Finished In 1mm Thick Laminate And All Side High Quality Germen Make Edge binding Or Biding Or Poly Urethane Paint.To Be Fixed, High Quality Imported D4 Grade Adhesive And All Necessary Hard Wares, Requires To Make The 6mm Thick Mirror All Side Polishes Etc Complete As Directed By Engineer In Charge Item No. 03 Free Standing Table @ 1500Lx600Dx750HT Providing and fixing Table of Size 1500 x 600 x 750 mm. Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs: C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel: Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY): Metal Powder Coated Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board, Item No. 04 Providing And Fixing Mirrors in Changing Room Full Height Mirror 800 x 1800mm H with 75 x 75mm Teakwood Framing. and Structure in 12mm Thick Bwr Plywood (Make century, Commander, city ply, Sharen, Euro Gold, Biz etc. or Equivalent Make) All Exposed & Unexposed Surfaces Covered Back Finished In 1mm Thick Laminate And All Side High Quality Germen Make Edge binding To Be Fixed, Limping Or Biding Or Poly Urethane Paint. High Quality Imported D4 Grade Adhesive And All Necessary Hard Wares, Requires To Make The 6mm Thick Mirror All Side Polishes Etc Complete As Directed By Engineer In Charge Item No. 05 Providing and Supllying Magazine Rack Size - 600 x 150 x 1200H Structure in 18mm Thick Bwt Plywood (Make century, Commander, city ply, Sharen, Euro Gold, Bizető or Equivalent Make) All Exposed & Unexposed Surfaces Covered Back Finished In 1mm Thick Laminate And All Side High Quality Germen Make Edge binding To Be Fixed, Limping Or Biding Or Poly Urethane Paint. High Quality Imported D4 Grade Adhesive And All Necessary Hard Wares, Etc Complete As Directed By Engineer In Charge Item No.06 Locker Cabinet: 1850 (H) x 380(W) x 450(D) mm Locker cabinet made from 1.2mm thick CRCA for Body and 1mm thick CRCA for Shutters (with perforation) and fitted by hinges which shall have 4 lockers in one column. Locking 4 Digit Combination Numeric Lock Handle / Label holder: Aesthetically appealing Snap fit ABS plastic handle. Item No. 07 Work desk counter: 4000mm (L) x 600mm (D) x 770mm (H), 40thk Table top and Sides made in 25 mm thick BWR plywood( Make century, Commander, city ply, Sharen Euro Gold, Biz etc. or Equivalent Make) All Exposed & Unexposed Surfaces Covered Back Finished In 1mm Thick Laminate And All Side High Quality Germen Make Edge binding To Be Fixed, Limping Or Biding Or Poly Urethane Paint. High Quality Imported D4 Grade Adhesivewith 2 nos, 25mm thk vertical side panels finished in laminate & recessed from the table top. 3 nos of drawers 90mm high X 600 (D) with telescopic channels, necessary hardrware etc as seen in the drawing. 2 nos storage unit fixed to the table of total height of 730 (h) x 500 (w) x 600 mm (d) which includes drawer of 140mm (h) x 500 (w) x 500 mm (d) with telescopic channels, handle and lock and necessary hardware in best quality. single openable shutter, 500mm high with shelf inside. This unit to have 75mm high recessed skirting detail. Table top to have provision for Cable managers. Etc Complete As Directed By Engineer In Charge Item No. 08 Full Height Steel Storage @ 750Lx450Dx2100HT Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 4 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns as as per drawing. Item No. 09 Wooden Credenza Storge unit Size: 4685mm (L) x 450 (D) X 1000 (H), 50high table top unit and shelves made in 18mm thick BWR Plywood (Make century, Commander, city ply, Sharen, Euro Gold, Biz etc. or Equivalent Make) All Exposed & Unexposed Surfaces Covered Back Finished In 1mm Thick Laminate And All Side High Quality Germen Make Edge binding To Be Fixed, Limping Or Biding Or Poly Urethane Paint. High Quality Imported D4 Grade Adhesive And All Necessary Hard Wares, Fevicol, Handles, Locks, Drawer Locks Hinges, Chanels.2 nos of shuttered storage units at both ends of the crdenza with shelf in between. 3 high skirting for the entire unit. 3 nos open storage unit with shelf in between. Etc Complete As Directed By Engineer In Charge Item No. 10 Füll Height Partitions in Glass finish Providing and Fixing 80mm to 85mm thick Full height Double Skin partition up to 3 mtr height with All visible sections in Anodized / Powdercoated finish. Made up of Frames and Tiles. Frame construction In combinaton of Aluminium Rails and Bottom, Center and Top members, Connected with 2 way Round Shape Post, 3way Post, 4 way Post made up of Aluminium Extruded and Tiles in 5mm thk. Non Toughened Glass on both side. With all the Joints in the partitions coverec with PVC extrusions to provide better sound Proofing. Tiles to be separated 55mm from each other to provide adequate space for drawing cables for electric, data and telephone with proper facility for fixing electrical and data switch plates. as per design and drawing. Item No. 11 Wooden Credenza Storge unit Size: 2400mm (L) x 450 mm (D) 750mm (H) unit and shelves made in 18mm thick BWR Plywood (Make century, Commander, city ply, Sharen, Euro Gold, Biz etc. or Equivalent Make) All Exposed & Unexposed Surfaces Covered Back Finished In 1mm Thick Laminate And All Side High Quality Germen Make Edge binding To Be Fixed, Limping Or Biding Or Poly Urethane Paint. High Quality Imported D4 Grade Adhesive And All Necessary Hard Wares, Fevicol, Handles, Locks, Drawer Locks, Hinges, Chanels, 3 high skirting for the entire credenza unit. 40mm high table top with laminate finish as approved. From 2400 length, 600mm wide to be open space. Remaining 1800mm to be divided into 4 parts with openable shutters Provision for 1 no wire manager Etc Complete As Directed By Engineer In Charge Item No.12 Office Chair Providing & Arrangemnt of Mid Back, Normal Syncro Mechanism, Fixed Armrest, Gaslift for Seat height adjustment, Standard 5-prong/Nylon Base with Leather Upholstery Item No. 13 12 Seater Reading Table for Library @ 3600Lx1200Dx750HT Providing and Fixing 12 Seater Reading Table for Liberary @ 3600Lx1200Dx750HT Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Gable Ends: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Modesty panel: Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine. Item No. 14 Reading Table desk 2 seater: Size: 1200 mm (L) x 1350mm (W) x 750mm (H) with 3 nos wooden vertical supports 675 (W) x 732 (H) x 40thk with protective shoe at the base, 2 nos modesty panels 700 x 332 (H) x 40thk.Common reaading desk made of 18mm BWR plywood (Make century, Commander, city ply, Sharen, Euro Gold, Biz etc. or Equivalent Make) with matt finish laminated material, All exposed sides to be 2mm PVC edgebinding with tharufid machine hot melt glue finish, Or Biding Or Poly Urethane Paint. base in Teakwood - finished is matt melamine polish, table mounted privacy panel of clear float glass 425mm (H) x 1200 (L) with light fixed on table top with S.S. Studs Etc Complete As Directed By Engineer In Charge Item No. 15 Computer Table: 10.00 Mtr L shaped counter width 600mm (D) x 40thk Table top, fixed at 770mm; withi all Vertical supports made in 18 mm thick BWR plywood( Make century, Commander, city ply, Sharen, Euro Gold, Biz etc. or Equivalent Make) All Exposed & Unexposed Surfaces Covered Back Finished In 1mm Thick Laminate And All Side High Quality Germen Make Edge binding To Be Fixed, Limping Or Biding Or Poly Urethane Paint. High Quality Imported D4 Grade Adhesive 10 nos keyboard tray 500 wide x 65mm high with And All Necessary Hard Wares, Fevicol, Handles, Locks, Drawer Locks, Hinges, Chanels in Laminate as approved by the architect. 9 nos. drawers of 500 (w) x 90mm (H) x 600mm (D)3 nos of drawers of varied lengths as shown in the drawing. Each computer to have Wire manager provided on the table top. If any additional support members are required, contractor to consult with Architect and add accordingly Etc Complete As Directed By Engineer In Charge Item No. 16 Manager Table Executives Table @ 1800Lx900Dx750HT Providing & Fixing of Table @ 1800Lx900Dx750HT TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band as per drawing Item No. 17 Medium Height Partition @ 1800/1200HT TILE BASED PARTITION SYSTEM Tile based Aluminum partition system of 1800/1200mm ht. made of 60mm thick aluminum frames having two separate race ways for laying electrical & computer wiring. The wire management shall be through to the race way to be fitted at bottom of partition other immediately below of work top with hook on type raceway cover for easy access of wires. Frames to be joined by aluminum connectors with M6 x 16 pan-head machine screw and washer with aluminum post cover. Post cover snap on fashion to be connected on aluminum connector visible aluminium to be in anodized / powdercoated finish. The top exposed sides of the frame and posts should be covered with horizontal/ Vertical trim and caps made of Aluminum in anodized / powdercoated finish in order to enhance its look. Upper tiles on the partition to be in Soft Board or Marker or prelaminated partical board tile of 9mm. thk., prelaminated partical board lower tiles in laminate finish 9mm. thk. on both the sides.Size :-1200/1800mm (H) Item No. 18 Book cases: Providing & fixing of Supply case with Glass shutter @ 825mm (L) x 380mm (D) x 1650mm (H). To be made out of complete body $ in 0.7mm thk CRCA & shutter in 1.2mm thk CRCA with glass panel in powder coated finish as per drawing. Item No. 19 Providig & Supply 1050mm diameter circular table, 750 (H), 40thk table top in Laminate finish in BWR Plywood All Expose Side to be 2mm PVC Edgebind with tharufid machin hot melt glue finished bottom side PVC bush fitted Including necessary hardware Best Quality with central support in good finish as approved. (Table similiar or equivalent to that available in Amardeep in Food court/cafe tables) Item No. 26 Wooden counter: 1450mm (L) x 500mm (D) x 750mm (H), 25thk Table, top and Sides made in 18 mm thick BWR plywood (Make century, Commander, city ply, Sharer Euro Gold, Biz etc. or Equivalent Make) All Exposed & Unexposed Surfaces Covered Back Finished In 1mm Thick Laminate And All Side High Quality Germen Make Edge binding To Be Fixed, Limping Or Biding Or Poly Urethane Paint. High Quality Imported D4 Grade Adhesive 3 drawers 125mm high And All Necessary Hard Wares, Fevicol, Handles, Locks, Drawer Locks, Hinges, Chanels Etc Complete As Directed By Engineer In Charge Item No. 27 Multiple Compartment Lockers @ 1140Lx 457D x 1830 mm. Ht. Providing and fixing Multiple Compartment Lockers @ 1140Lx 457D x 1830 mm. Ht. with 12 Compartments, Complete body & shutter made of CRCA Sheet with powder coated finish as per approved color. Item No. 28 Conference Table @ 1800 x 900 x 750 mm Ht. Providing & Fixing of Main Table @ 1800Lx900Dx750HT - made up of 18+18mm Thick MDF top with PVC Membrane finish and waterfall edge profile. Aluminium Anodizied finish beeding of 4mm thich is running all over the table top edge. Gable ends is Aerofoiled Shape with front edges in PVC Membrane finish and rest in Prelaminated MDF with batton structure. Gable ends should be hollow from inside for the provision of passing electrical and Data wiring., MODESTY PANEL:- to be made of 18 mm thick Prelaminated particle board with PVC edge band Access Flap:- For Wire manager 1 Nos. Item No. 29 Below Counter Cabinets: Size: 5020mm (L) x 590mm (D) x 750(H) with 40mm thk top made in 18mm thick BWR Plywood (Make century, Commander, city ply, Sharen Euro Gold, Biz etc. or Equivalent Make) All Exposed & Unexposed Surfaces Covered Back Finished In 1mm Thick Laminate And All Side High Quality Germen Make Edge binding To Be Fixed, Limping Or Biding Or Poly Urethane Paint. High Quality Imported D4 Grade Adhesive And All Necessary Hard Wares, Fevicol, Handles, Locks, Drawer Locks, Hinges, Chanels Etc Complete As Directed By Engineer In Charge Item No. 30 Providing And Supplying Display Case: Floor standing museum display cabinets of size; width 1.2m, Depth 0.6m, & Height 2m. The Display case is made up of 8mm thick toughened glass on the three sides and one side of glass is openable using hinge/sliding mechanism to access artifacts. Base pedestal framing is made of galvanised steel square pipes covered with 20 gauge galvanised steel sheets and epoxy powder coated after fabrication. Silica gel trays are provided below the artifacts for humidity control. A Item No. 31 Overhead Counter Storage: Size: 2100mm (L) x 350mm (D) x 1000(H) @ 600mm above kitchen Blatform with openable shutters, all necessary hardware in best quality. Unit and shelves made in 18mm thick BWR Plywood (Make century, Commander, city ply, Sharen, Euro Gold, Biz etc. or Equivalent Make) All Exposed & Unexposed Surfaces Covered Back Finished In 1mm Thick Laminate And All Side High Quality Germen Make Edge binding To Be Fixed, Limping Or Biding Or Poly Urethane Paint. High Quality Imported D4 Grade Adhesive And All Necessary Hard Wares, Fevicol, Handles, Locks, Drawer Locks Hinges, Chanels Etc Complete As Directed By Engineer In Charge Item No. 32 Provding and Supplying Dining Table 4 seater: 765 mm (W) x 765mm (D) x 705(H), Square table with straight legs (same design as 6 seater) in Brown color as approved by the architect. Premium Chair Without Arm in Rattan Finish of size 490 mm (W) x 545mm (D) x 880(H) Item No. 33 Provding and Supplying Dining Table 6 seater with chair: 900 mm (W) x 1600mm (D) x 720(H), Premium Finish Heavy Duty 6 seater dining table with extra board & wide table top & contemporary style solid built legs in Brown color as approved by the architect. Premium Chair Without Arm in Rattan Finish of size 490 mm (W) x 545mm (D) x 880(H) Item No. 34 Ticket counter: 3000mm (L) x 600mm (D) x 770mm (H), 40thk Table top and Sides made in 25 mm thick BWR plywood (Make century, Commander, city ply, Sharen Euro Gold, Biz etc. or Equivalent Make) All Exposed & Unexposed Surfaces Covered Back Finished In 1mm Thick Laminate And All Side High Quality Germen Make Edge binding To Be Fixed, Limping Or Biding Or Poly Urethane Paint. High Quality Imported D4 Grade Adhesive table top 6 nos of drawers 90mm high & 2 nos drawers 140mm high, the length of table. 2 nos storage unit fixed to the table of total height of 730 (h) x 370 (w) x 600 mm (d) which includes drawer of 140mm (h) x 370 (w) x 600 mm (d), single openable shutter, 505 mm high with shelf inside. This unit to have 75mm high recessed skirting detail. Table top to have provision for Cable managers And All Necessary Hard Wares, Fevicol, Handles, Locks, Drawer Locks, Hinges, Chanels Etc Complete As Directed By Engineer In Charge Item No. 35 Providing & Fixing Wall Paneling Structure Supporting System Made Of 1.5X1.5 Thk Ply Stripes (Provided @.60 X 60cm C/C In Both Direction) Made Up Of 18mm Plywood Made, Quality Make( Mr Grade Commercial Plywood.) Quality Make (Century, Commander, City Ply, Sharen, Biz Etc. Or Equivalent) Provided Front Covered With 18 Mm Ply, Including All Necessary Hard Wares Etc. Complete, As Per Detailed Drawing & Design Attached Including Cost Of All Materials, Lead, Labours, Necessary Fixtures And Fastening, Etc. Complete As Directed By Engineer In Charge. Item No. 36 Providing and fixing laminated wooden flooring in position having thickness 8mm including 6mm Thick Hitloan Sheet with Rubber Soletion & all necessary hard wares, & Profile Like Scarting, Reducers & Bidding as per detailed drawing & design attached including cutting & matching,cost of all materials, lead, labours, necessary fixtures and fastening,etc. complete & as directed. Item No. 37 Providing & Fixing in position, 6mm Carpet more than 800+gsm, made with100% stain proof fibres fibres of approved make along with 6mm under lay as per Architectural & Acoustical Design & Instructions & Complete in all aspects including al materials labour, finishing etc complete Item No. 38 PVC Carpet Flooring Providing and fixing PVC Vinyl Planks 2mm thick for Flooring with Ready made adhesive including cleaning surface before laying dising, pattern colour etc Item No. 39 Providing And Fixing Plywood Partitions Made Up Of Supporting System Mad Of 1.5X1.5 Thk Ply Stripes Frame Of Size 75mm X 50mm At 60cm C/C With 9 Mm Thick Quality Make(Mr Grade Commercial Plywood.) Quality Make (Century, Commander, City Ply, Sharen, Biz Etc. Or Equivalent )Y On Both Sides Including All Necessary Hard Wares Etc. Complete, As Per Detailed Drawing & Design Attached Including Cost Of All Materials, Lead, Labours, Necessary Fixtures And Fastening, Etc. Complete As Directed By Engineer In Charge. Item No. 40 Recepation counter and side table provinding and fixing side instolation of the 2.15 x .60 x 1.2mt & .09 x .45 x .75mt Below counter storage required size 0.60 width made out of 18mm thick commercial plywood with shutter, drawer and selves & back wall of counter 18mm thick Plywood shutter drwar table table top counter and front side of ounter is lamintor 10mm thick lamination above table 10mm thick glass is fixed with side TW decorative post over the counter as per desing including good quality off approved hardware such as lock, handle, hinges ball cature channel of approved company beading requored as per drawing etc Item No. 41 Providing & Fixing Murals, ISO FRP material having 6mm thickness, as per the photograph and drawings, casted by sculptor approved by P.W.D Including preparation of clay/pop model (model to be approved by the architect), preparation of base for painting with duco brand putty & primer, two coat of atomotive paint, working dwg will be provided Item No. 42 Providing And Fixing In Position Gypsum Board False Ceiling With12.5mm Thick Gypsum Boards, Screwed/Fixed To The Under Structure Of Suspended G.I.Grid Constructed And Suspended From The Main Ceiling Consisting Of Ceiling Sections Of Size 25x50mm Maximum Center To Center Distance Of 600 Millimeter Perimeter Channel And Intermediate Channels At Maximum Center To Center Distance1200milimetre Galvanized Grid Should Be Fixed To Reinforce Dcement concrete Slab. The Gypsum Board Should Be Fixed To Galvanize Painting Including Labor, Material, Lifts Etc. All Complete. Item No. 43 Providing, and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling System with ultima (Beyelled Tegular) Edge Tiles of size 15mm Exposed GRID. The les should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k = 0.052 0.057 w/m K, Colour White, Fire Performance UK Class 0/ Class 1 (BS 476 pt 6&7) in module size of 600 x 600 x 20mm, suitable for Green Building application, with Recycled content of 32%. The tile shall be laid on precoated G.I.channel on XL2 Clip having a web height of 32 mm with 15 mm wide T section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm and 600 mm Cross Tees with a web height of 32 mm and a load carrying capacity of 7.7 Kilograms/M2 and minimum pull out strength of 100 Kilograms.. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system. The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. Item No. 44 METAL BAFFLE CEILING: Providing & fixing of horizontal level suspended ceiling comprising of Vertical Linear Baffle Ceiling made out of Aluminum Extrusion in Aluminum alloy grade 6063 T5. The baffle blade shall be in size of 100x25x3600mm in powder coated to Woodgrain/Plain finish (Red Oak, Cherry, Black & White).. The baffle shall be electrostatically polyester powder coated to a coating thickness of 60-80 micron. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV-A Test for 1000hours as per ASTM G-154 (Cycle 1) and Humidity test for 1000hours as per DIN 50017. The powder coating shall have an adhesion of GTO as per EN ISO 2409. The shade variation within a manufacturing batch shall be delta E<1 using Excite/BYK Gardner instrument and gloss level 25±5 at 60° as per ASTM D523 (Not applicable of Wood Grain Shade). The baffle blade shall be suspended using Slotted U- profile of 20 x 30 x 3700mm (Thk-1.5mm) having slots in module of 25mm to keep baffles at an on-center spacing in multiples of 25mm. Longer lengths of Baffle to be connected by Baffle Joiner and the ends to be fixed with End caps..SUSPENSION: Shall be hanged using baffle hanger from U-profile made of mild steel with powder coating thickness of 60-80 micron. The U profile to comprise of alternate square & rectangular slots of 6.5x6.5mm & 28x6.5mm respectively on the web for locking the baffle hanger using plugin clip to secure the hanger in perfect position and achieve uniform spacing between baffles. The overall dimension of the U profile is 20(W) x 30(H) x 3750(L) mm and is rolled form from 1.5mm thick mild steel with a powder coating thickness of 60-80micron. U- Profile to be connected to each other using U -Profile Splice. The U- profile shall be hanged from the true ceiling using threaded rod using a U- Profile hanger. The Baffle along with suspension system used together shall carry a 10 year warranty against manufacturing defect and manufacturer shall provide a warranty certificate. The supply shall be backed by a Manufacturing Test Certificate. Item No. 45 Providing And Supplying Heavy Duty Stackable Chairs Fibre hard PVC with bend plywood seat and backrest, stackable Etc Complete به 6 Item No. 46 Providing & Arrangemnt of Mid Back, ECO CTS Mechanism, Fixed Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric Upholstery Item No. 47 Providing & Arrangement Of High Back Chair Tilt Mechanism With Multilocking, High Density Cushion On Seat Composite Leather With Metallic Silver Finish Base And Arms With P.U.Castors Gas lift For Height Adjustment. Item No. 48 Providing & Arrangemnt of High Back, Synchronized Mechanism with Multiple Locking, Adjustable Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery Item No. 49 Providing And Fixing Textured Wall Paper Of Approved Make And Quality To Walls Including Surface Making Adhesive Scaffolding Making All Other Surfaces In Good Floor Clearing Etc Complete
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
Contract Date: Mar 09, 2026 Contract Value : 16.80 Lakh
Local Bodies No of Bidders 3
Maharashtra View Result →
TenderDetail
Loading tenders