View Bid Results For Demolition Hammer Tenders

We found 257 Bid Results related to demolition hammer tenders. You can find Contractor details who won demolition hammer tenders along with contract details in Bid awards announcements section.

Filters
Stage
216
33
8
Tender Publishing Platform
77
180
State / UT
33
46
28
24
21
19
15
12
10
9
8
7
5
5
4
4
4
4
4
3
3
3
3
2
2
2
2
2
1
1
1
1
1
1
Contract Value
80
70
92
15
Publish Date
0
1
0
0
0
Sector
19
133
50
19
13
13
8
4
3
3
2
1
1
1
1
1
1
1
1
1
Ownership
4
123
61
52
21
Within keyword
Active filters:
Showing 1–6 of 257 tenders matching your filters
2.
Public Administrative Department #11389337 AOC
Procurement Of Rescue Equipment & Tools For The Newly Procured Trucks Of The Directorate Of ( Ev&Dm ) , Ghmc ( 3Rd Call ) .--1 Waist Harness: Waist Safety climbing harness outdoor rock climbing harness, half body harness safe seat belt for mountaineering expanding tree arborist climbing rappelling :Petzl (make) or its equivalent. 2 Safety Net of Size 10mx3m, Made from high strength Polypropylene Ropes which are able to withstand required load, Special Knotting of the meshes work towards effective Shock Absorption, hence minimizing any impact related injury on to the worker, Cost inclusive of supply, transportation, delivery, installation, all applicable taxes and any other incidental charges. 3 Rope Ladder of 10ft Length, it should bear minimum load of 120 kg, Cost inclusive of supply, transportation, delivery, installation, all applicable taxes and any other incidental charges . 4 Polypropylene Ropes - Diameter 12mm , Cost inclusive of supply, transportation, delivery, installation, all applicable taxes and any other incidental charges (bundle of 30 metres length) . 5 Polypropylene Ropes - Diameter 24mm , Cost inclusive of supply, transportation, delivery, installation, all applicable taxes and any other incidental charges (bundle of 30 metres length) . 6 Life Buoys. Made from durable high visibility synthetic material maintenance free Reflective tape provided Inner dia- 45 cms Outer dia 70 cms Floatability- more than 17 kgs Weight- 2.3 to 3.5 kgs . 7 Life Jackets. Brand Tribord 100 Newtons or its equivalent quality. 8 Telescopic Ladder. Fully collapsible, 150kg load-bearing capacity, Lightweight Aluminium design, Compacts to 100cm or less, Height-320 CM x Width-47 CM, Cost inclusive of supply, transportation, delivery, installation, all applicable taxes and any other incidental charges 9 Chain saw Petrol Make :Hitachi Model: CS40EA, or its equivalent, Cost inclusive of supply, transportation, delivery, installation, all applicable taxes and any other incidental charges 10 Chain saw Electrical Make :Hitachi Model: CS40Y, 2KW or its equivalent 11 Demolition hammer : minimum impact force – 25J, rated power input – 1500 W, Low-vibration in operation and no-load, Low feed pressure, for fatigue-free working, Make and model: Bosch GSH 11 E or its Equivalent, Cost inclusive of supply, transportation, delivery, installation, all applicable taxes and any other incidental charges 12 Slab cutter: Minimum Cutting capacity of 100mm, 2400W motor, easy to handle and maintenance, vibration free, Make and Model: Hitachi CM 12Yor its Equivalent, Cost inclusive of supply, transportation, delivery, installation, all applicable taxes and any other incidental charges 13 Spade Cost inclusive of supply, transportation, delivery, all applicable taxes and any other incidental charges 14 Plastic Construction Tub Cost inclusive of supply, transportation, delivery, all applicable taxes and any other incidental charges 15 Heavy Duty 900 Grams Cutting Axe Size 43 x 11 x 18 cm with Strong Wooden Handle. Sharpened Blade in 20 mm Strong Iron of standard size and standard make: tata/its equivalent, Cost inclusive of supply, transportation, delivery, installation, all applicable taxes and any other incidental charges 16 Shovel with Steel Handle,(Tata make or equivalent),with minimum weight of 1.5 kgs, Cost inclusive of supply, transportation, delivery, all applicable taxes and any other incidental charges 17 Bolt Cutter – should be capable of cutting rods of diameter up to 36 mm, Make and model: Taparia BC36 or its Equivalent, Cost inclusive of supply, transportation, delivery, installation, all applicable taxes and any other incidental charges 18 Pole saw ,8 feet Electric Pole chainsaw, minimum Bar Length: 20 Cm Cost inclusive of supply, transportation, delivery, installation, all applicable taxes and any other incidental charges 19 Iron Crow Bar (Tata make oe equivalent),Overall length(5 Mts),Thickness(22mm) ,Cost inclusive of supply, transportation, delivery, all applicable taxes and any other incidental charges. 20 Sledge Hammer (12 IBS) Cost inclusive of supply, transportation, delivery, all applicable taxes and any other incidental charges 21 Gas cutters Set including all accessories except cylinders, Cost inclusive of supply, transportation, delivery, installation, all applicable taxes and any other incidental charges (Gas cooled, oxyacetelene, LPG, weight - 500 gms, thickness -4 mm, Hose length -3mtr, Nozzle Material -CU. 22 1 HP Submersible pump – electrical, self priming, Make: Kirlosker/Suguna or Equivalent, Cost inclusive of supply, transportation, delivery, installation, all applicable taxes and any other incidental charges 23 Diesel Driven Pump 6.5 HP Make: Kirlosker or its equivalent. Cost inclusive of supply, transportation, delivery, installation, all applicable taxes and any other incidental charges 24 Generator 7.5KVA , 3 Phase, Self start, liquid air cooled, silent in operation, vibration free, compatible for mounting & running in vehicle, Make: Kirlosker or its equivalent. Cost inclusive of supply, transportation, delivery, installation, all applicable taxes and any other incidental charges 25 Hose pipe 2.5 Dia (30 mtr.) 26 Metal Rake 3 feet 27 Hose pipe 4.5 Dia (30 mtr.) 28 Fire Balls AFO : ABC Fire Extinguisher, Fire Suppression Device, self-activating within 3 – 5 seconds, weight up to 3kg, Cost inclusive of supply, transportation, delivery, installation and any other incidental charges. 29 Stored pressure type ABC 4kg fire Extinguishers SAFE PRO / Its Equivalent 30 Gum Boots: light weight, pvc material, slip and heat resistant, make: Duck Back or its Equivalent, Cost inclusive of supply, transportation, delivery, installation and any other incidental charges. 31 Anti – Skid Hand Gloves: Make: Neoprene or its equivalent, Nitrile coated palm, smooth and rough-texture palm finish. 32 Safety Helmet with LED: Material: made by HDPE, Size: 520mm – 600mm Dia, Suspension: 4-point cradle, Weight: approximately 370 grams, Shell thickness: 3mm, Sweat band: Brushed cloth on foam to provide maximum comfort to user, Color: White, Knob type adjustable Helmet for perfect head size, Working temperature: -20C to +50C(in Degree Celsius), Withstand voltage: 1200V specifications of LED Head lamp, LED illuminated torch, Shell material: ABS, Laser: minimum 10W, Rated power: minimum 3W, Rated capacity: minimum 200mAh, Battery type: lithium battery, LED life expectancy: minimum 100000Hours, Waterproofing grade: IPX3, Working temperature: -20 to +50 (in Degree Celsius), Back up time: minimum 6 to 8 hours, Full recharge time: maximum 6 hours, Volt charger: 6V, Cost inclusive of supply, transportation, delivery, installation and any other incidental charges. 33 Rechargeable Long Range LED Dragon Light , 10 WATT, Make: ASKA or Equivalent, Lithium-Ion Battery min 5800mAH, High, Medium, Low, SOS &Flash, Dimensions(mm): 224LX165WX172H 34 Hand Tool kit, Tool kit should consists minimum of : 9-Pieces Screwdriver Bits, 6-Pieces Hexagon Socket Wrench, 8-Pieces Precision Bits, 2-Pieces Adaptors, 1-Piece Ratchet Hand Screwdrivers, 8-Pieces Allen Keys, 3-Pieces Masonry Drill Bits, 30-Pieces S-Plugs, 30-Pieces Screws, 1-Piece Flat-Nose Pliers, 1-Piece Combination Pliers, 1-Piece Tester, 1-Piece Hammer, 1-Piece Cutter, 1-Piece Measuring Tape 3m, 1-Piece Insulation Tape, 1-Piece Torch, 1-Piece Wrench, 1-Piece Handsaw, Make and model: Bosch 2.607.002.790 All-in-One Metal Hand Tool Kit (Blue, 108-Pieces) or its Equivalent, Cost inclusive of supply, transportation, delivery, installation, all applicable taxes and any other incidental charges 35 Megaphone AHUJA AM 21SM or its equivalent 36 Barricading cone & Chain : Minimum height: 750mm, with 1mtr chain, Color: Orange, material should have High flexibility to avoid crushing, reflective sleeve for day-night high visibility. Cost inclusive of supply, transportation, delivery, installation and any other incidental charges. 37 3 Core wire in metres (4 Sqmm). Make: Finecab or Equivalent, Cost inclusive of supply, transportation, delivery, installation, all applicable taxes and any other incidental charges 38 4 Core wire in metres (4 Sqmm).Make: Finecab or its Equivalent, Cost inclusive of supply, transportation, delivery, installation, all applicable taxes and any other incidental charges 39 Camping chair of standard size: Seat height maximum of 41 cm, minimum load bearing capacity 110kg, Make: Quechua or its Equivalent. Cost inclusive of supply, transportation, delivery, installation and any other incidental charges. 40 Medical Kit with all standard first aid items, Compatible for travels, vehicle mounted with Dimensions: Width 30 cm, Height 12 cm, Depth 12 cm, Weight 1 kg
Contract Date: Ref. Documents Contract Value : 22.81 Lakh
Local Bodies No of Bidders 1
3.
Public Administrative Department #11341972 AOC
Tender For Rate For Water Supply And Hand Pump Repairing Material As Given In The List For The Financial Year 2025-26-- 1 Inviting rate for Water Supply and Hand pump Repairing Material as given in the list for the financial year 2025-26 2 AMPELLERFOR 20 HP MOTOR 3 ANGLE GLINDER 801 4 BASH BASIN BRACKET 5 BOTTLE TREP FOR BASIN 6 BRASSVALVE 1/2 7 BRASSVALVE 2 8 BRASSVALVE 3 9 BRASSVALVE 4 10 BRASSVALVE1.5 11 BRASSVALVE 1 12 BRASSVALVE 3/4 13 BRASSVALVE1.25 14 CASING PIPE ISI MARK10 15 CASING PIPE ISI MARK12 16 CASING PIPE ISI MARK6 17 CASING PIPE ISI MARK7 18 CASING PIPE ISI MARK8 19 CASING SOCKET10 20 CASING SOCKET12 21 CASING SOCKET5 22 CASING SOCKET6 23 CASING SOCKET7 24 CASING SOCKET8 25 CHAIN SAWCHAIN 16 26 CHAIN SAWCHAIN 18 27 CHAIN SAWELECTRIC22 28 CHAIN SAWPETTROL 16 29 CI BAND ISI MARK 3 30 CI BAND ISI MARK2 31 CI BAND ISI MARK4 32 CI BAND ISI MARK6 33 CI BAND ISI MARK7 34 CI BAND ISI MARK8 35 CI BAND ISI MARK 10 36 CI BAND ISI MARK 12 37 CI BAND ISI MARK 2.5 38 CI PIPE ISI MARK 3 39 CI PIPE ISI MARK2 40 CI PIPE ISI MARK4 41 CI PIPE ISI MARK6 42 CI PIPE ISI MARK7 43 CI PIPE ISI MARK8 44 CI PIPE ISI MARK 10 45 CI PIPE ISI MARK 12 46 CI PIPE ISI MARK 2.5 47 CI TEE ISI MARK 3 48 CI TEE ISI MARK2 49 CI TEE ISI MARK4 50 CI TEE ISI MARK6 51 CI TEE ISI MARK7 52 CI TEE ISI MARK8 53 CI TEE ISI MARK 10 54 CI TEE ISI MARK 12 55 CI TEE ISI MARK 2.5 56 CI HANDLE VALVE 1/2 57 CI HANDLE VALVE 2 58 CI HANDLE VALVE 3 59 CI HANDLE VALVE 4 60 CI HANDLE VALVE1.5 61 CI HANDLE VALVE 1 62 CI HANDLE VALVE 3/4 63 CI HANDLE VALVE1.25 64 COMPOUND RUBBER 65 CONDENSOR 200 - 250 MFD 66 CONDENSOR 25 MFD 67 CONDENSOR 36 MFD 68 CONDENSOR 50 MFD 69 CONNECTIONCLAMP HEAVY WITH NUT BOLT 2 70 CONNECTIONCLAMP HEAVY WITH NUT BOLT 2.5 71 CONNECTIONCLAMP HEAVY WITH NUT BOLT10 72 CONNECTIONCLAMP HEAVY WITH NUT BOLT12 73 CONNECTIONCLAMP HEAVY WITH NUT BOLT3 74 CONNECTIONCLAMP HEAVY WITH NUT BOLT4 75 CONNECTIONCLAMP HEAVY WITH NUT BOLT6 76 CONNECTIONCLAMP HEAVY WITH NUT BOLT7 77 CONNECTIONCLAMP HEAVY WITH NUT BOLT8 78 CONNECTION PIPE 12 for washbasin 79 CONNECTION PIPE 18 for washbasin 80 CONNECTION PIPE 24 for washbasin 81 CONNECTION PIPE 30 for washbasin 82 CONNECTION PIPE 36 for washbasin 83 CONNECTION PIPE 48 for washbasin 84 CONNECTION PIPE 60 for washbasin 85 CUT OFF WHEEL (LOHA CUTTER BLADE)10 86 CUT OFF WHEEL (LOHA CUTTER BLADE)12 87 CUT OFF WHEEL (LOHA CUTTER BLADE)14 88 CUT OFF WHEEL (LOHA CUTTER BLADE)4 89 CUT OFF WHEEL (LOHA CUTTER BLADE)5 90 CUT OFF WHEEL (LOHA CUTTER BLADE)6 91 CUT OFF WHEEL (LOHA CUTTER BLADE)8 92 D JOINT CI LINE2 93 D JOINT CI LINE2.5 94 D JOINT CI LINE 10 95 D JOINT CI LINE 12 96 D JOINT CI LINE 3 97 D JOINT CI LINE 4 98 D JOINT CI LINE 6 99 D JOINT CI LINE 8 100 D JOINT GI LINE2 101 D JOINT GI LINE2.5 102 D JOINT GI LINE 10 103 D JOINT GI LINE 12 104 D JOINT GI LINE 3 105 D JOINT GI LINE 4 106 D JOINT GI LINE 6 107 D JOINT GI LINE 8 108 DEMOLITION HAMMER 16 KG 109 DEMOLITION HAMMER 6 KG 110 DHAGA 111 DRILL MACHINE 10 MM 112 DRILL MACHINE 13 MM 113 EXTENSION NIPPULE 1 Steel 114 EXTENSION NIPPULE 1.5 Steel 115 EXTENSION NIPPULE 2 Steel 116 FASTNER 117 FLENCH WASHER2 118 FLENCH WASHER2.5 119 FLENCH WASHER 3 120 FLENCH WASHER 4 121 FOOT BALL2 122 FOOT BALL 2.5 123 FOOT BALL3 124 FOOT BALL4 125 FOOT BALLWASHER2 126 FOOT BALLWASHER2.5 127 FOOT BALLWASHER 3 128 FOOT BALLWASHER4 129 GARDEN PIPE HEAVY DUTY1/2 130 GARDEN PIPE HEAVY DUTY1 131 GARDEN PIPE HEAVY DUTY3/4 132 GASKET 10 133 GASKET 12 134 GASKET 3 135 GASKET 4 136 GASKET 6 137 GASKET 8 138 GI BAND1.5 139 GI BAND2.5 140 GI BAND 1 141 GI BAND 1.25 142 GI BAND 1/2 143 GI BAND 2 144 GI BAND 3 145 GI BAND 3/4 146 GI BAND 4 147 GI BAND 6 148 GI CHEKNUT 2.5*2 149 GI CHEKNUT 3*2.5 150 GI CHEKNUT 4*2 151 GI CHEKNUT 4*3 152 GI ELBOW 4 153 GI ELBOW6 154 GI ELBOW 1.5 155 GI ELBOW 2.5 156 GI ELBOW1 157 GI ELBOW1.25 158 GI ELBOW1/2 159 GI ELBOW2 160 GI ELBOW3 161 GI ELBOW3/4 162 GI PIPE 1.5 163 GI PIPE 2.5 164 GI PIPE1 165 GI PIPE1.25 166 GI PIPE1/2 167 GI PIPE2 168 GI PIPE3 169 GI PIPE3/4 170 GI PIPE4 171 GI PIPE6 172 GI REDUCER 2.5*2 173 GI REDUCER 3*2.5 174 GI REDUCER 4*2 175 GI REDUCER 4*3 176 GI SOCKET1.5 177 GI SOCKET2.5 178 GI SOCKET 1 179 GI SOCKET 1.25 180 GI SOCKET 1/2 181 GI SOCKET 2 182 GI SOCKET 3 183 GI SOCKET 3/4 184 GI SOCKET4 185 GI SOCKET 10 186 GI SOCKET 12 187 GI SOCKET 6 188 GI SOCKET 7 189 GI SOCKET 8 190 GI TEE4 191 GI TEE 6 192 GI TEE1.5 193 GI TEE2.5 194 GI TEE 1 195 GI TEE 1.25 196 GI TEE 1/2 197 GI TEE 2 198 GI TEE 3 199 GI TEE 3/4 200 GI THREADED NIPPULE1.5 201 GI THREADED NIPPULE 2.5 202 GI THREADED NIPPULE1 203 GI THREADED NIPPULE 1.25 204 GI THREADED NIPPULE 1/2 205 GI THREADED NIPPULE 2 206 GI THREADED NIPPULE 3 207 GI THREADED NIPPULE 3/4 208 GI THREADED NIPPULE 4 209 GI UNION4 210 GI UNION 6 211 GI UNION1.5 212 GI UNION2.5 213 GI UNION 1 214 GI UNION 1.25 215 GI UNION 1/2 216 GI UNION 2 217 GI UNION 3 218 GI UNION 3/4 219 GI WIRE 220 GLAN DORI 221 GUNMETAL BUSH20 HP 222 HAMMER DRILL 3 STEP 26 MM 223 HANDPUMP 32 M.M G.I PIPE B CLASS 10 FEET 224 HANDPUMP BANK 225 HANDPUMP BARRING 6202 226 HANDPUMP BARRING 6204 227 HANDPUMP CHAIN 228 HANDPUMP COMPLETE 229 HANDPUMP CYLINDER 230 HANDPUMP CYLINDER BRACKET 231 HANDPUMP CYLINDER FULL BRASS FITTINGS 232 HANDPUMP D.I 233 HANDPUMP EXEL 234 HANDPUMP HANDLE 235 HANDPUMP HEAD CHAMBER 236 HANDPUMP LINK ROD 237 HANDPUMP LOWER VALVE WASHER 238 HANDPUMP LOWER WALL FULL BRASS 239 HANDPUMP LOWER WALL NORMAL 240 HANDPUMP MASTER PIECE 241 HANDPUMP PEDESTAL BODY 242 HANDPUMP PEETAL CYLINDER 243 HANDPUMP PIPE SOCKET 244 HANDPUMP ROD SOCKET 245 HANDPUMP UPER VALVE STOOL 246 HANDPUMP UPER VALVE STOOL WASHER 247 HANDPUMP UPPER WALL FULL BRASS 248 HANDPUMP UPPER WALL NORMAL 249 HANDPUMP UPPPER VALVE WASHER 250 HANDPUMP WASHER SET COMPLETE 251 HANDPUMP WATER HEAD CHAMBER 252 HATHODA 2 POUND 253 ISI MARK PE 63 1 HDPE PIPE 254 ISI MARK PE 631.25 HDPE PIPE 255 ISI MARK PE 631.5 HDPE PIPE 256 ISI MARK PE 632 HDPE PIPE 257 ISI MARK PE 632.5 HDPE PIPE 258 ISI MARK PE 633 HDPE PIPE 259 ISI MARK PE 634 HDPE PIPE 260 ISI MARK PE 63 3/4 HDPE PIPE 261 HEX NIPPULE STEEL 1 262 HEX NIPPULESTEEL 1/2 263 HEX NIPPULE STEEL 3/4 264 HEXA BLADE DOUBLE 265 HEXA BLADE SINGLE 266 HEXA FRAME 267 HOSE CLAMP1.5 268 HOSE CLAMP2.5 269 HOSE CLAMP 1 270 HOSE CLAMP 1.25 271 HOSE CLAMP 1/2 272 HOSE CLAMP 2 273 HOSE CLAMP 3 274 HOSE CLAMP 3/4 275 HOSE CLAMP 4 276 HOSE CLAMP 6 277 HOSE NIPPULE 2 278 HOSE NIPPULE2.5 279 HOSE NIPPULE 10 280 HOSE NIPPULE 3 281 HOSE NIPPULE 4 282 HOSE NIPPULE 6 283 HOSE NIPPULE 8 284 FUSE 100 AMP Cut out 285 FUSE 200 AMP Cut out 286 FUSE 300 AMP Cut out 287 FUSE 32 AMP Cut out 288 FUSE 500 AMP Cut out 289 FUSE 63 AMP Cut out 290 FUSE WIRE 291 LATHER PACKING SHEET 292 M SEAL BADI 293 M SEAL CHHOTI 294 MARVEL CUTTER BLADE 10 295 MARVEL CUTTER BLADE 4 296 MARVEL CUTTER BLADE 5 297 MARVEL CUTTER BLADE 6 298 MARVEL CUTTER BLADE 8 299 NEON BULB TESTER 300 NON RETURN VALVE 1.5 301 NON RETURN VALVE 2.5 302 NON RETURN VALVE1 303 NON RETURN VALVE1.25 304 NON RETURN VALVE1/2 305 NON RETURN VALVE2 306 NON RETURN VALVE3 307 NON RETURN VALVE3/4 308 NON RETURN VALVE4 309 NON RETURN VALVE6 310 NOSE PLIER 311 NUT BOLT 312 OPENWELL PUMP 1 HP 313 OPENWELL PUMP 1.5 HP 314 OPENWELL PUMP 2 HP 315 ORISA PAN 21 316 ORISA PAN 23 317 PATTI PANA12*13 318 PATTI PANA14*15 319 PATTI PANA16*17 320 PATTI PANA18*19 321 PATTI PANA20*22 322 PATTI PANA21*23 323 PATTI PANA24*27 324 PATTI PANA30*32 325 PATTI PANA5/16*7/16 326 PATTI PANA7/16*9/16 327 PIPE WRENCH HEAVY DUTY10 328 PIPE WRENCH HEAVY DUTY 12 329 PIPE WRENCH HEAVY DUTY 14 330 PIPE WRENCH HEAVY DUTY 18 331 PIPE WRENCH HEAVY DUTY 24 332 PLIER8 333 PVC PIPE1/2 334 PVC PIPE2 335 PVC PIPE 1.5 336 PVC PIPE1 337 PVC PIPE3/4 338 PVC PIPE 1.25 339 PVC PIPE SOCKET 4 340 PVC PIPE SOCKET 1.5 341 PVC PIPE SOCKET 2.5 342 PVC PIPE SOCKET1.25 343 PVC PIPE SOCKET2 344 PVC PIPE SOCKET3 345 PVC REDUCER 2.5*2 346 PVC REDUCER 3*2.5 347 PVC REDUCER 4*2 348 PVC REDUCER 4*3 349 PVC SOCKET1/2 350 PVC SOCKET2 351 PVC SOCKET 1.5 352 PVC SOCKET1 353 PVC SOCKET3/4 354 PVC SOCKET 1.25 355 PVC TEE1/2 356 PVC TEE2 357 PVC TEE 1.5 358 PVC TEE1 359 PVC TEE3/4 360 PVC TEE 1.25 361 RINGPANA 12*13 362 RINGPANA 14*15 363 RINGPANA 16*17 364 RINGPANA 18*19 365 RINGPANA 20*22 366 RINGPANA 21*23 367 RINGPANA 24*27 368 RINGPANA 30*32 369 RINGPANA 5/16*7/16 370 RINGPANA 7/16*9/16 371 RUBBER RING CI LINE2 372 RUBBER RING CI LINE2.5 373 RUBBER RING CI LINE 10 374 RUBBER RING CI LINE 12 375 RUBBER RING CI LINE 3 376 RUBBER RING CI LINE 4 377 RUBBER RING CI LINE 6 378 RUBBER RING CI LINE 8 379 RUBBER RING CI LINE 10 380 RUBBER RING CI LINE 12 381 RUBBER RING CI LINE 14 382 RUBBER RING CI LINE 16 383 RUBBER RING GI LINE2 384 RUBBER RING GI LINE2.5 385 RUBBER RING GI LINE 10 386 RUBBER RING GI LINE 12 387 RUBBER RING GI LINE 3 388 RUBBER RING GI LINE 4 389 RUBBER RING GI LINE 6 390 RUBBER RING GI LINE 8 391 RUBBER RING GI LINE 10 392 RUBBER RING GI LINE 12 393 SAFEDA BADA 394 SAFEDA CHOTA 395 SCREW DRIVER12 396 SCREW DRIVER15 397 SCREW DRIVER6 398 SCREW DRIVER9 399 1 SUCTION PIPE 400 1.25 SUCTION N PIPE 401 1.5 SUCTION PIPE 402 2 SUCTIONPIPE 403 2.5 SUCTIONPIPE 404 3 SUCTIONPIPE 405 4 SUCTIONPIPE 406 3/4 SUCTIONPIPE 407 6 SUCTIONPIPE 408 SINK 24*18*9 409 SINK COUPLING 410 SLUICE VALVE 2 411 SLUICE VALVE10 412 SLUICE VALVE12 413 SLUICE VALVE3 414 SLUICE VALVE4 415 SLUICE VALVE6 416 SLUICE VALVE8 417 SLUICE VALVE10 418 SLUICE VALVE12 419 SLUICE VALVE16 420 SOCKET NIPPULE2 421 SOCKET NIPPULE2.5 422 SOCKET NIPPULE 10 423 SOCKET NIPPULE 3 424 SOCKET NIPPULE 4 425 SOCKET NIPPULE 6 426 SOCKET NIPPULE 8 427 STARTER OIL 1 LITER BOTTLE 428 TAFLON TAPE 429 TAIL PIECE CI LINE 2 430 TAIL PIECE CI LINE10 431 TAIL PIECE CI LINE12 432 TAIL PIECE CI LINE3 433 TAIL PIECE CI LINE4 434 TAIL PIECE CI LINE6 435 TAIL PIECE CI LINE8 436 TAIL PIECE CI LINE10 437 TAIL PIECE CI LINE12 438 TAIL PIECE CI LINE14 439 TAIL PIECE CI LINE16 440 TAIL PIECE GI LINE 2 441 TAIL PIECE GI LINE10 442 TAIL PIECE GI LINE12 443 TAIL PIECE GI LINE3 444 TAIL PIECE GI LINE4 445 TAIL PIECE GI LINE6 446 TAIL PIECE GI LINE8 447 TAIL PIECE GI LINE10 448 TAIL PIECE GI LINE12 449 TOCHAN RASSI ISI MARK 10 MM 450 TOCHAN RASSI ISI MARK 12 MM 451 TOCHAN RASSI ISI MARK 14 MM 452 TOCHAN RASSI ISI MARK 16 MM 453 TOCHAN RASSI ISI MARK 18 MM 454 TOCHAN RASSI ISI MARK 20 MM 455 URENAL BRACKET 456 URENAL GENTSHALF STAL 457 URENAL GENTSMINI 458 URENAL GENTSSMALL 459 URENAL LADIES 460 URENAL PUSH ANGLE COCK 461 URENAL WASTE PIPE 462 WASH BASIN 22*16 463 WIRE WELDING 12 M.M. 464 WIRE WELDING 16 M.M. 465 WIRING TAPE 466 SUBMERSIBLE MOTOR PUMP SET COMPLETE 1 HP 467 SUBMERSIBLE MOTOR PUMP SET COMPLETE 1.5 HP 468 SUBMERSIBLE MOTOR PUMP SET COMPLETE 3 HP 469 SUBMERSIBLE CABLE 3 CORE 6 MM 470 SUBMERSIBLE CABLE 3 CORE 10 MM 471 SUBMERSIBLE PUMP BUSHING 10 HP 472 SUBMERSIBLE PUMP BUSHING15 HP 473 SUBMERSIBLE PUMP BUSHING20 HP 474 MONOBLOCK MOTOR AMPELLER 1 HP 475 MONOBLOCK MOTOR AMPELLER 10 HP 476 MONOBLOCK MOTOR AMPELLER 15 HP 477 MONOBLOCK MOTOR AMPELLER 20 HP 478 BALL BEARING NBC 6203 479 BALL BEARING NBC 6204 480 BALL BEARING NBC 6307 481 BALL BEARING NBC 6308 482 AP3 BALL BEARING GREES 500 GM
Contract Date: Jun 23, 2026 Contract Value : 17.01 Lakh
Local Bodies No of Bidders 3
Madhya Pradesh View Result →
4.
Public Administrative Department #11333649 AOC
Procurement Of Rescue Equipments And Tools For 8 Nos Of Newly Procured Trucks In Directorate Of Evdm Ghmc-1 Waist Harness: Waist Safety Climbing Harness Outdoor Rock Climbing Harness, Half Body Harness Safe Seat Belt For Mountaineering Expanding Tree Arborist Climbing Rappelling :Petzl ( Make ) Or Its Equivalent. 2 Safety Net Of Size 10Mx3m, Made From High Strength Polypropylene Ropes Which Are Able To Withstand Required Load, Special Knotting Of The Meshes Work Towards Effective Shock Absorption, Hence Minimizing Any Impact Related Injury On To The Worker, Cost Inclusive Of Supply, Transportation, Delivery, Installation, All Applicable Taxes And Any Other Incidental Charges 3 Rope Ladder Of 10Ft Length, It Should Bear Minimum Load Of 120 Kg, Cost Inclusive Of Supply, Transportation, Delivery, Installation, All Applicable Taxes And Any Other Incidental Charges 4 Polypropylene Ropes - Diameter 12Mm, Cost Inclusive Of Supply, Transportation, Delivery, Installation, All Applicable Taxes And Any Other Incidental Charges ( Bundle Of 30 Metres Length ) 5 Polypropylene Ropes - Diameter 24Mm, Cost Inclusive Of Supply, Transportation, Delivery, Installation, All Applicable Taxes And Any Other Incidental Charges ( Bundle Of 30 Metres Length ) 6 Life Buoys. Made From Durable High Visibility Synthetic Material Maintenance Free Reflective Tape Provided Inner Dia- 45 Cms Outer Dia 70 Cms Floatability- More Than 17 Kgs Weight- 2.3 To 3.5 Kgs 7 Life Jackets. Brand Tribord 100 Newtons Or Its Equivalent Quality. 8 Telescopic Ladder. Fully Collapsible, 150Kg Load-Bearing Capacity, Lightweight Aluminium Design, Compacts To 100Cm Or Less, Height-320 Cm X Width-47 Cm, Cost Inclusive Of Supply, Transportation, Delivery, Installation, All Applicable Taxes And Any Other Incidental Charges 9 Chain Saw Petrol Make :Hitachi Model: Cs40ea, Or Its Equivalent, Cost Inclusive Of Supply, Transportation, Delivery, Installation, All Applicable Taxes And Any Other Incidental Charges 10 Chain Saw Electrical Make :Hitachi Model: Cs40y, 2Kw Or Its Equivalent 11 Demolition Hammer: Minimum Impact Force – 25J, Rated Power Input – 1500 W, Low-Vibration In Operation And No-Load, Low Feed Pressure, For Fatigue-Free Working, Make And Model: Bosch Gsh 11 E Or Its Equivalent, Cost Inclusive Of Supply, Transportation, Delivery, Installation, All Applicable Taxes And Any Other Incidental Charges 12 Slab Cutter: Minimum Cutting Capacity Of 100Mm, 2400W Motor, Easy To Handle And Maintenance, Vibration Free, Make And Model: Hitachi Cm 12Yor Its Equivalent, Cost Inclusive Of Supply, Transportation, Delivery, Installation, All Applicable Taxes And Any Other Incidental Charges 13 Spade Cost Inclusive Of Supply, Transportation, Delivery, All Applicable Taxes And Any Other Incidental Charges 14 Plastic Construction Tub Cost Inclusive Of Supply, Transportation, Delivery, All Applicable Taxes And Any Other Incidental Charges 15 Heavy Duty 900 Grams Cutting Axe Size 43 X 11 X 18 Cm With Strong Wooden Handle. Sharpened Blade In 20 Mm Strong Iron Of Standard Size And Standard Make: Tata / Its Equivalent, Cost Inclusive Of Supply, Transportation, Delivery, Installation, All Applicable Taxes And Any Other Incidental Charges 16 Shovel With Steel Handle, ( Tata Make Or Equivalent ) , With Minimum Weight Of 1.5 Kgs, Cost Inclusive Of Supply, Transportation, Delivery, All Applicable Taxes And Any Other Incidental Charges 17 Bolt Cutter – Should Be Capable Of Cutting Rods Of Diameter Up To 36 Mm, Make And Model: Taparia Bc36 Or Its Equivalent, Cost Inclusive Of Supply, Transportation, Delivery, Installation, All Applicable Taxes And Any Other Incidental Charges 18 Pole Saw , 8 Feet Electric Pole Chainsaw, Minimum Bar Length: 20 Cm Cost Inclusive Of Supply, Transportation, Delivery, Installation, All Applicable Taxes And Any Other Incidental Charges 19 Iron Crow Bar ( Tata Make Oe Equivalent ) , Overall Length ( 5 Mts ) , Thickness ( 22Mm ) , Cost Inclusive Of Supply, Transportation, Delivery, All Applicable Taxes And Any Other Incidental Charges 20 Sledge Hammer ( 12 Ibs ) Cost Inclusive Of Supply, Transportation, Delivery, All Applicable Taxes And Any Other Incidental Charges 21 Gas Cutters Set Including All Accessories Except Cylinders, Cost Inclusive Of Supply, Transportation, Delivery, Installation, All Applicable Taxes And Any Other Incidental Charges ( Gas Cooled, Oxyacetelene, Lpg, Weight - 500 Gms, Thickness -4 Mm, Hose Length -3Mtr, Nozzle Material -Cu. 22 1 Hp Submersible Pump – Electrical, Self Priming, Make: Kirlosker / Suguna Or Equivalent, Cost Inclusive Of Supply, Transportation, Delivery, Installation, All Applicable Taxes And Any Other Incidental Charges 23 Diesel Driven Pump 6.5 Hp Make: Kirlosker Or Its Equivalent. Cost Inclusive Of Supply, Transportation, Delivery, Installation, All Applicable Taxes And Any Other Incidental Charges 24 Generator 7.5Kva, 3 Phase, Self Start, Liquid Air Cooled, Silent In Operation, Vibration Free, Compatible For Mounting & Running In Vehicle, Make: Kirlosker Or Its Equivalent. Cost Inclusive Of Supply, Transportation, Delivery, Installation, All Applicable Taxes And Any Other Incidental Charges 25 Generator 5 Kva Honda ( Sku:Ab-Hd-20211348 ) Self Start, Liquid Air Cooled, Silent In Operation, Vibration Free, Compatible For Mounting & Running In Vehicle, Make: Kirlosker Or Its Equivalent. Cost Inclusive Of Supply, Transportation, Delivery, Installation, All Applicable Taxes And Any Other Incidental Charges 26 Hose Pipe 2.5 Dia ( 30 Mtr. ) 27 Metal Rake 3 Feet 28 Hose Pipe 4.5 Dia ( 30 Mtr. ) 29 Fire Balls Afo: Abc Fire Extinguisher, Fire Suppression Device, Self-Activating Within 3 – 5 Seconds, Weight Up To 3Kg, Cost Inclusive Of Supply, Transportation, Delivery, Installation And Any Other Incidental Charges. 30 Stored Pressure Type Abc 4Kg Fire Extinguishers Safe Pro / Its Equivalent 31 Fire Suit ( Consist Of Helmet Made Of Ptfe Material Of En 443:2008 Or Nfpa 1971:2007 , Jacket, Trouser, Hand Gloves ( Certified To En 659:2008 Or Nfpa 1971:2007, Balacava, Fireman Boot ( Retardant & Shock Proof Certified To En 15090:2012 Type 3 Or Nfpa 1971:2007 ) . 32 Gum Boots: Light Weight, Pvc Material, Slip And Heat Resistant, Make: Duck Back Or Its Equivalent, Cost Inclusive Of Supply, Transportation, Delivery, Installation And Any Other Incidental Charges. 33 Anti – Skid Hand Gloves: Make: Neoprene Or Its Equivalent, Nitrile Coated Palm, Smooth And Rough-Texture Palm Finish. 34 Safety Helmet With Led: Material: Made By Hdpe, Size: 520Mm – 600Mm Dia, Suspension: 4-Point Cradle, Weight: Approximately 370 Grams, Shell Thickness: 3Mm, Sweat Band: Brushed Cloth On Foam To Provide Maximum Comfort To User, Color: White, Knob Type Adjustable Helmet For Perfect Head Size, Working Temperature: -20C To +50C ( In Degree Celsius ) , Withstand Voltage: 1200V Specifications Of Led Head Lamp, Led Illuminated Torch, Shell Material: Abs, Laser: Minimum 10W, Rated Power: Minimum 3W, Rated Capacity: Minimum 200Mah, Battery Type: Lithium Battery, Led Life Expectancy: Minimum 100000Hours, Waterproofing Grade: Ipx3, Working Temperature: -20 To +50 ( In Degree Celsius ) , Back Up Time: Minimum 6 To 8 Hours, Full Recharge Time: Maximum 6 Hours, Volt Charger: 6V, Cost Inclusive Of Supply, Transportation, Delivery, Installation And Any Other Incidental Charges. 35 Rechargeable Long Range Led Dragon Light, 10 Watt, Make: Aska Or Equivalent, Lithium-Ion Battery Min 5800Mah, High, Medium, Low, Sos &Flash, Dimensions ( Mm ) : 224Lx165wx172h 36 Hand Tool Kit, Tool Kit Should Consists Minimum Of : 9-Pieces Screwdriver Bits, 6-Pieces Hexagon Socket Wrench, 8-Pieces Precision Bits, 2-Pieces Adaptors, 1-Piece Ratchet Hand Screwdrivers, 8-Pieces Allen Keys, 3-Pieces Masonry Drill Bits, 30-Pieces S-Plugs, 30-Pieces Screws, 1-Piece Flat-Nose Pliers, 1-Piece Combination Pliers, 1-Piece Tester, 1-Piece Hammer, 1-Piece Cutter, 1-Piece Measuring Tape 3M, 1-Piece Insulation Tape, 1-Piece Torch, 1-Piece Wrench, 1-Piece Handsaw, Make And Model: Bosch 2.607.002.790 All-In-One Metal Hand Tool Kit ( Blue, 108-Pieces ) Or Its Equivalent, Cost Inclusive Of Supply, Transportation, Delivery, Installation, All Applicable Taxes And Any Other Incidental Charges 37 Megaphone Ahuja Am 21Sm Or Its Equivalent 38 Barricading Cone & Chain: Minimum Height: 750Mm, With 1Mtr Chain, Color: Orange, Material Should Have High Flexibility To Avoid Crushing, Reflective Sleeve For Day-Night High Visibility. Cost Inclusive Of Supply, Transportation, Delivery, Installation And Any Other Incidental Charges. 39 3 Core Wire In Metres ( 4 Sqmm ) . Make: Finecab Or Equivalent, Cost Inclusive Of Supply, Transportation, Delivery, Installation, All Applicable Taxes And Any Other Incidental Charges 40 4 Core Wire In Metres ( 4 Sqmm ) .Make: Finecab Or Its Equivalent, Cost Inclusive Of Supply, Transportation, Delivery, Installation, All Applicable Taxes And Any Other Incidental Charges 41 Camping Chair Of Standard Size: Seat Height Maximum Of 41 Cm, Minimum Load Bearing Capacity 110Kg, Make: Quechua Or Its Equivalent. Cost Inclusive Of Supply, Transportation, Delivery, Installation And Any Other Incidental Charges. 42 Medical Kit With All Standard First Aid Items, Compatible For Travels, Vehicle Mounted With Dimensions: Width 30 Cm, Height 12 Cm, Depth 12 Cm, Weight 1 Kg
Contract Date: Ref. Documents Contract Value : 58.54 Lakh
Local Bodies No of Bidders 1
Contract Date: Ref. Documents Contract Value : 3.20 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 8
6.
Public Administrative Department #11317170 Technical Bid
Tender for Invite Rate For Supply Of Cleaning Material As Per Requirement For The Year 2026-2027 , Invite Rate For Cleaning Material For Nagar Palika Makronia , Supply Of Good Quality Rapid Floor Wiper Big , Supply Of Good Quality Swing Bins 24 Ltr , Supply Of Good Quality Swing Bins 80 Ltr , Supply Of Good Quality Two Wheel Swing Bins 120 Ltr , Supply Of Good Quality Mug 500 Ml , Supply Of Good Quality Mug 1000 Ml , Supply Of Good Quality Decent Toilet Brush , Supply Of Good Quality Crowbar 5 Kg , Supply Of Good Quality Magnum Pedal Bins 15 Ltr , Supply Of Good Quality Magnum Pedal Bins 20 Ltr , Supply Of Good Quality Magnum Pedal Bins 30 Ltr , Supply Of Good Quality Aqua Bucket09 Ltr , Supply Of Good Quality Aqua Bucket12 Ltr , Supply Of Good Quality Aqua Bucket17 Ltr , Supply Of Good Quality Aqua Bucket20 Ltr , Supply Of Good Quality Aqua Bucket30 Ltr , Supply Of Good Quality Soap Case Plane , Supply Of Good Quality Soap Case Printed , Supply Of Good Quality Soap Dish , Supply Of Good Quality Mug 1500 Ml , Supply Of Good Quality Sprayer 500 Ml , Supply Of Good Quality Sprayer 750 Ml , Supply Of Good Quality Sprayer 1000 Ml , Supply Of Good Quality Lundry Basket 65 Ltr , Supply Of Good Quality Drums 25 Ltr , Supply Of Good Quality Drums 32 Ltr , Supply Of Good Quality Drums 50 Ltr , Supply Of Good Quality Storage Buckets With Flat Lids 80Lrt , Supply Of Good Quality Storage Buckets With Flat Lids 120Lrt , Supply Of Good Quality Planters 16 Number , Supply Of Good Quality Rainbow Planters 16 Number , Supply Of Good Quality Square Planters 16 Number , Supply Of Good Quality Pine Planters 8.5 Ltr , Supply Of Good Quality Creeper Planter 0.8 Lrt , Supply Of Good Quality Activa Toilect Brush , Supply Of Good Quality Double Hockey Toilet Brush , Supply Of Good Quality Cosmos Brush , Supply Of Good Quality Aroma Toilet Brush With Stand , Supply Of Good Quality Unique Dust Pan , Unique Dust Pan With Brush , Supply Of Good Quality Big Dust Pan , Supply Of Good Quality Small Dust Pan , Supply Of Good Quality Mini Dust Pan , Supply Of Good Quality Clean Dust Pan , Supply Of Good Quality Magnum Pedal Bins 10 Ltr , Supply Of Good Quality Rapid Floor Wiper Small , Supply Of Good Quality Floor Brush Big , Supply Of Good Quality Floor Dori Mop , Supply Of Good Quality Mop Big , Supply Of Good Quality Plaza Broom Small , Supply Of Good Quality Plaza Broom Big , Supply Of Good Quality Dust Broom Xl Extra Large , Supply Of Good Quality Dust Broom Regular , Supply Of Good Quality Mop Bucket Plane , Supply Of Good Quality Spin Mop Bucket , Supply Of Good Quality Swing Bins 7.5 Ltr , Supply Of Good Quality Swing Bins 14 Ltr , Supply Of Good Quality Mild Steel Three Bins Dustbin With Stand With Installation , Supply Of Good Quality Plastic Three Bins Dustbin With Stand With Installation , Supply Of Good Quality Mild Steel Portable Toilet Single , Supply Of Good Quality Mild Steel Portable Toilet Double , Supply Of Good Quality Frp Toilet , Supply Of Good Quality Plastic Dustbin For House , Supply Of Good Quality Iron Chair , Supply Of Good Quality Frp Animal Dustbins , Supply Of Good Quality Big Plastic Container 1100 Ltr , Supply Of Good Quality Stainless Steel Dustbins 60 Ltr Grade 202 With Stand , Supply Of Good Quality Stainless Steel Dustbins 40 Ltr Grade 202 With Stand , Supply Of Good Quality Stainless Steel Dustbins 30 Ltr Grade 202 With Stand , Supply Of Good Quality Stainless Steel Dustbins 20 Ltr Grade 202 With Stand , Supply Of Good Quality Big Container 1100 Ltr , Supply Of Good Quality Cow Catcher Four Wheels , Supply Of Good Quality Wheelbarrow , Supply Of Good Quality Two Wheel Mild Steel Garbage Hand Cart 350 Ltr , Supply Of Good Quality Digging Shovel , Supply Of Good Quality Spade Fork , Supply Of Good Quality Heavy Duty Ghamela Iron , Supply Of Good Quality Heavy Duty Ghamela Plastic , Supply Of Good Quality Steel Hoe Head Heavy Duty , Supply Of Good Quality Spade , Supply Of Good Quality Barbed Wire , Supply Of Good Quality Hammer , Supply Of Good Quality Rasp , Supply Of Good Quality Employee Shirt Cloth Par Meter , Supply Of Good Quality Employee Pent Cloth Par Meter , Supply Of Good Quality Employee Saree For Women , Supply Of Good Quality Employee Uniform For Men , Supply Of Good Quality Employee Uniform For Women , Supply Of Good Quality Padlocks Four Key Xl , Supply Of Good Quality Track Shut For Man , Supply Of Good Quality Track Shut For Women , Supply Of Good Quality Welcome Door Mat Joot , Supply Of Good Quality Welcome Door Mat Pvc , Supply Of Good Quality Welcome Door Mat Standred Size , Supply Of Good Quality Candle/Mombatti , Supply Of Good Quality Grass Cutter Machine With Adjustable Electric , Supply Of Good Quality Petrol Brush Cutter And Grass Cutter Machine Double Eagle 2-Stroke , Supply Of Good Quality Heavy Duty Concrete Drilling Machine 950 Rpm, 4500 Bpm Rotary Hammer , Supply Of Good Quality Heavy-Duty Metal Cut-Off Saw , Supply Of Good Quality Heavy Duty Concrete & Masonry Breaker Demolition Hammer , Supply Of Good Quality Waterlabs Tds Meter , Supply Of Good Quality Waterlabs Ph Meter , Supply Of Good Quality Disposable Hand Gloves - Transparent (100No. Box) , Supply Of Good Quality Coblat Blue Powder Free Nitrile Hand Gloves , Supply Of Good Quality Heavy Duty Rubber Hand Gloves For Cleaning , Supply Of Good Quality Supply Of Good Quality Nylon Safety Cut Resistant Hand Gloves , Supply Of Good Quality Heat/Fire Resistant Gloves , Supply Of Good Quality Face Shield With Glasses, Face Mask , Supply Of Good Quality Disposable Transparent Face Shield , Supply Of Good Quality N95 Anti Pollution Face Mask , Supply Of Good Quality Premium N95 Mask For Men And Women With Mask Adjuster , Supply Of Good Quality Steel Cleaning Dustpan Supdi , Supply Of Good Quality Garbage Shovel Wind Proof With Brush , Supply Of Good Quality Waste-Collecting Trowel , Supply Of Good Quality Metal Head, Wooden Handlecultivator , Supply Of Good Quality Hand Tool Cultivator With Plastic Sleeve , Supply Of Good Quality Hand Tool Cultivator With Iron , Supply Of Good Quality Hand Tool Cultivator With Iron Heavy Duty , Supply Of Good Quality Plastic Unbreakable Without Handle Kudal , Supply Of Good Quality Plastic Unbreakable With Handle Kudal , Supply Of Good Quality Iron Without Handle Kudal , Supply Of Good Quality Heavy-Duty Hand Tool With 7X10 Spade Blade , Supply Of Good Quality Wooden Spade Shovel Hoe Handle , Supply Of Good Quality Spade Handle Wood Wooden Shaft Shaft Sparetapered , Supply Of Good Quality Medium Size Spade With Iron Pipe And Plastic Handle , Supply Of Good Quality Nylon Rope 10Mm , Supply Of Good Quality Nylon Rope 20Mm , Supply Of Good Quality Natural Coconut Leaf Grass Broom , Supply Of Good Quality Coconut Broom Unpeed , Supply Of Good Quality Bamboo Stick Compound Broom , Supply Of Good Quality Wooden Stick , Supply Of Good Quality Wooden Broom Handle Stick Standard Size , Supply Of Good Quality Safety Jacket For Men And Women Reflective High Visibility , Supply Of Good Quality Safety Jacket For Men And Women Reflective High Visibility With Ulb Name And Slogan As Per Requirments , Supply Of Good Quality High Visibility Protective Safety Reflective Vest Belt , Supply Of Good Quality Safety Helmet For Men Helmet , Supply Of Good Quality Raincoat 100% Waterproof Polyester Man/Woman , Supply Of Good Quality Green Net , Supply Of Good Quality Cotton Wet Mop Refil , Supply Of Good Quality Dry Mop Microfiber Mop , Supply Of Good Quality Floor Wiper Single Blade , Supply Of Good Quality Floor Wiper Double Blade , Supply Of Good Quality Check Duster Cloths , Supply Of Good Quality Floor Duster Mop Cloth , Supply Of Good Quality Multipurpose Floor Brush , Supply Of Good Quality Microfiber Feather Duster , Supply Of Good Quality Hand Scrubber , Supply Of Good Quality Garbage Bags , Supply Of Good Quality Tissue Papers, M-Fold , Supply Of Good Quality Soap Dispensers , Supply Of Good Quality Auto Hand Dryer , Supply Of Good Quality Cobweb Brush , Supply Of Good Quality Glass Wiper Commercial , Supply Of Good Quality Combi Glass Washer & Wiper , Supply Of Good Quality Urinal Screen , Supply Of Good Quality Scrubber Handle , Supply Of Good Quality Tissue Paper Dispenser , Supply Of Good Quality Godrej Aroma Dispenser , Supply Of Good Quality Bathroom Fresheners , Supply Of Good Quality Single Disc Machine , Supply Of Good Quality Vacuum Cleaners & High Pressure Washers , Supply Of Good Quality Auto Scrubber Dryer Floor Cleaning Machine , Supply Of Good Quality Mini Hand Scrubber , Supply Of Good Quality Nepthalene Balls , Supply Of Good Quality Air Revitalizer , Supply Of Good Quality Westley Cup & Saucer , Supply Of Good Quality Dustbin Bags , Supply Of Good Quality Shovel With Tata Company Bent , Supply Of Good Quality Spade (Small 1.2 Kg) With Tata Company Bent , Supply Of Good Quality Spade (Big 1.8 Kg) With Tata Company Bent , Supply Of Good Quality Pickaxe (3 Kg) With Tata Company Bent , Supply Of Good Quality Small Spade With Tata Company Bent , Supply Of Good Quality Claw Rag Lifter , Supply Of Good Quality Forked Spade With Bent , Supply Of Good Quality Iron Tag (2 Kg) , Supply Of Good Quality Plastic Tag (Isi) Pvc Tata Company Big , Supply Of Good Quality Plastic Tag (Isi) Pvc Tata Company Big , Supply Of Good Quality Sickle Heavy With Bent , Supply Of Good Quality Tangia/Axe With Bent , Supply Of Good Quality Jhumad/Hammer With Bent , Supply Of Good Quality Shabbar 1 Thick 5 Feet Long , Supply Of Good Quality Shabbar 1 Thick 3 Feet Long , Supply Of Good Quality Khurpa Heavy With Bent , Supply Of Good Quality Barbed Claw Heavy 12 Feet Long Made , Supply Of Good Quality Gumboot Aar Paar Company , Supply Of Good Quality Spray Machine 15 Liter Manual , Supply Of Good Quality Spray Machine 15 Liter Battery Operated , Supply Of Good Quality 2.5 Inch Fire Canvas Pipe Bundle Brass Mail And Female Cupler With Fitting , Supply Of Good Quality Fogging Hand Machine Per Piece , Supply Of Good Quality Hand Soap 125 Gm Per Piece , Supply Of Good Quality Cloth Soap 250 Gm Per Piece , Supply Of Good Quality Pp Kit (Covering The Whole Body) Per Set , Supply Of Good Quality Sanitary Pads (Pack Of 15-18 Pieces) Per Packet , Supply Of Good Quality Track Suit (Sport) Polyester Per Piece , Supply Of Good Quality Fleece Jersey Piece For Winter , Supply Of Good Quality Grass Cutter Talwar , Supply Of Good Quality Heavy Duty Hedge Shear With Sharp Blade , Supply Of Good Quality Falcon Super Pruning Secateur Heavy Duty Garden Cutter , Supply Of Good Quality 2 In 1 Double Hand Hoe Gardening Tool With Wooden Handle , Supply Of Good Quality Bush Trimmer & Cutter , Supply Of Good Quality Chain Saw , Supply Of Good Quality Gasoline Chain Saw , Supply Of Good Quality Total Pressure Sprayer 2 Ltr , Supply Of Good Quality Petrol Power Rotary Lawn Mower - 18-Inch Heavy-Duty Cutter , Supply Of Good Quality 30Mtr Braided Hose Pipe , Supply Of Good Quality Garden Hose Pipe 1 Milky 30 Mtr , Supply Of Good Quality Garden Plant Flower Bulb Auger, 4 X 12 Easy Planter Garden Auger , Supply Of Good Quality Petrol Earth Auger , Supply Of Good Quality Precast Concrete Poles For Gardens And Fencing , Supply Of Good Quality Precast Concrete Bench For Garden , Supply Of Good Quality Plant Pots Outdoor Square Garden Planters Concrete , Supply Of Good Quality Mild Steel Tree Guard , Supply Of Good Quality Wire Mesh Fencing , Supply Of Good Quality Bamboo-Tree Guard , Supply Of Good Quality Tree Guard Net_Garden Fencing Net Pvc Virgin Hdpe , Supply Of Good Quality All Out Ultra Liquid Vaporizer, 2 Refills , Supply Of Good Quality Gud Night Ultra Liquid Vaporizer, 2 Refills , Supply Of Good Quality Mosquito Repellent Mats , Supply Of Good Quality Cap With Ulb And Slogan Name , Supply Of Good Quality Surgical Mask 100 Pc In A Box , Supply Of Good Quality Iron Hand Cultivator (Panji)
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 4
Madhya Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 97,911
Boards / Undertakings / PSU No of Bidders 8
10.
Public Administrative Department #11251885 Technical Bid
Tender for Annual Tender For Water Supply Material , Water Supply Material , G.I Pipe 1 Inch , G.I Pipe 2.Inch , G.I Pipe 3 Inch , G.I Socket 1 Inch , G.I Socket 1.25 Inch Long , G.I Socket 2.Inch , G.I Socket 2.Inch Long , G.I Socket 3 Inch , G.I Elbow 1 Inch , G.I Elbow 1.25 Inch , G.I Elbow 2.Inch , G.I Elbow 3 Inch , G.I Tee 1 Inch , G.I Tee 1.25 Inch , G.I Tee 2.Inch , G.I Tee 3 Inch , Hdpe Pipe 1 Inch , Hdpe Pipe 1.25 Inch , Hdpe Pipe 2 Inch , Hdpe Pipe 3 Inch , Hdpe Nipple 1 Inch , Hdpe Nipple 1.25 Inch , Hdpe Nipple 2 Inch , Hdpe Nipple 3 Inch , Hdpe Equle Tee 1 Inch , Hdpe Equle Tee 1.25 Inch , Hdpe Equle Tee 2 Inch , Hdpe Equle Tee 3 Inch , Hdpe Elbow 1 Inch , Hdpe Elbow 1.25 Inch , Hdpe Elbow 2 Inch , Hdpe Elbow 3 Inch , Hdpe Bend 1 Inch , Hdpe Bend 1.25 Inch , Hdpe Bend 2 Inch , Hdpe Bend 3 Inch , S.S. Clamp With Nut Bolt, 2 Inches , A.C. Pipe 4 Inches , Washer No. 2 And 3 , Brass Elbow 1/2 Inch , Brass Elbow 1 Inch , Brass Elbow 3/4 Inch , Raw Rubber , Cable 2.5 Mm And 6 Mm (National/Kisan/Texmo) , Connection Cable 4 Mm / Armored - Isi , Connection Cable 6 Mm / Armored - Isi , Pvc Saddle Clamp Set For Pipe Connection 1 Inch , Pvc Saddle Clamp Set For Pipe Connection 1.25 Inch , Pvc Saddle Clamp Set For Pipe Connection 2 Inch , Pvc Saddle Clamp Set For Pipe Connection 3 Inch , Ms Saddle Clamp Set For Pipe Connection 1 Inch , Ms Saddle Clamp Set For Pipe Connection 1.25 Inch , Ms Saddle Clamp Set For Pipe Connection 2 Inch , Ms Saddle Clamp Set For Pipe Connection 3 Inch , Hose Clamp S.S. 1 Inch , Hose Clamp S.S. 1.25 Inch , Hose Clamp S.S. 2 Inch , Hose Clamp S.S. 3 Inch , Pvc Socket 1 Inch , Pvc Socket 1/2 Inch , Pvc Socket 3/4 Inch , Pvc Valve 1 Inch , Pvc Valve 1/2 Inch , Pvc Valve 3/4 Inch , Pvc Tee 1 Inch , Pvc Tee 2 Inches , Pvc Teflon Tape , Pvc Gate Valve 1 Inch (Kisan/Texmo) , Pvc Gate Valve 1/2 Inch (Kisan/Texmo) , Pvc Gate Valve 2 Inches (Kisan/Texmo) , Pvc Gate Valve 3/4 Inch (Kisan/Texmo) , Pvc Elbow 1 Inch (Kisan/Texmo) , Pvc Elbow 1/2 Inch (Kisan/Texmo) , Pvc Elbow 2 Inches (Kisan/Texmo) , Pvc Elbow 3/4 Inch (Kisan/Texmo) , Pvc Casing Pipe Plain Pipe 100 Mm (Kasta/Kisan) , Pvc Pipe 1 Inch (Kisan/Texmo) , Pvc Pipe 1/2 Inch (Kisan/Texmo) , Pvc Pipe 3/4 Inch (Kisan/Texmo) , Pvc Pipe 1.25 Inch (Kisan/Texmo) , Pipe Wrench 12 Inches , Pipe Wrench 14 Inches , Pipe Wrench 16 Inches , Pipe Lifter 2.25 Inches , Pipe Die 1.25 Inch , Panel Board 15 Hp Three Phase Bentex (Automatic) , Patti Clamp 1 Inch (Isi) , Patti Clamp 1.25 Inch (Isi) , Patti Clamp 2 Inches (Isi) , Patti Clamp 3 Inches (Isi) , Rubber Ring 80 Mm (Isi) 3 Inches , Rubber Ring 100 Mm (Isi) 4 Inches , Rubber Ring 125 Mm (Isi) 5 Inches , Rubber Ring 150 Mm (Isi) 6 Inches , Rubber Seat Packing , Rod Die , C.I. Flange 2 Inches , C.I. Flange 3 Inches , C.I. Flange 4 Inches , C.I. Reducer Tee 100X100 Mm (Isi) , C.I. Reducer Tee 80X100 Mm (Isi) , C.I. Reducer Tee 100X100x150 Mm (Isi) , C.I. Reducer Tee 80X80x100 Mm (Isi) , C.I. Tee 100X100x100 Mm (Isi) , C.I. Tee 100X100x80 Mm (Isi) , C.I. Tee 150X150x150 Mm (Isi) , C.I. Tee 80X80x100 Mm (Isi) , C.I. Tee 80X80x80 Mm (Isi) , C.I. Tail Piece 100 Mm (Isi) , Solvent , White Cement , Water Tank 500 Liters (Syntex/Kisan/Texmo) , Water Tank 1000 Liters (Syntex/Kisan/Texmo) , Vice Handpump No. 4 , Chain Pulley Block 3 Tons , Nut And Bolt , Tail Piece 2, 3, And 4 Inches , Gate Valve 1 Inch , Gate Valve 2 Inches , Gate Valve 3 Inches , Gate Valve 4 Inches , Gate Valve Brass 1 Inch - Isi , Gate Valve Brass 1/2 Inch - Isi , Gate Valve Brass 3/4 Inch - Isi , Gate Valve Brass 2 Inches - Isi , Gland Rope , End Cap Pvc 1 Inch , End Cap Pvc 1/2 Inch , End Cap Pvc 3/4 Inch , D Joint Ci 3 Inches , D Joint Ci 4 Inches , D Joint Ci 6 Inches , Hdpe D Joint 2.5 Inches , Hdpe D Joint 3 Inches , Hdpe D Joint 4 Inches , Hand Grinder Machine 1600 Watt Bosch 5 Inch , Hand Grinder Blade 5 Inch And 6 Inch , Hammer Machine 1500 Watt 26 Mm Bosch , Breaker Machine Demolition 5 Kg , Fusing Machine , Sluice Valve 50 Mm , Sluice Valve 75 Mm , Sluice Valve 90 Mm , Sluice Valve 110 Mm , Tee 75 Mm , Tee 90 Mm , Reducer Socket Gi 1.25 Inch-1.5 Inch , Reducer Socket Gi 2 Inch -1.25 Inch , Reducer Socket Gi 3 Inch -2 Inch , Reducer Socket Pvc 1.25 Inch-1.5 Inch , Reducer Socket Pvc 2 Inch -1.25 Inch , Reducer Socket Pvc 3 Inch -2 Inch , Starter 3 Hp , Starter 2 Hp , Hdpe Pipe Jointing Machine 1Inch To 3Inch , Packing Handpump , G.I. Tail Piece 6 X 1 Ft , G.I. Tail Piece 6 X 2.5 Ft , 1.25 Inch Gate Valve Pvc , 1.25 Inch T Pvc , 1.25 Inch Albow Pvc , 1.25 Inch Socket Pvc , 1.25 Inch End Cape Pvc , 1.25 Inch Saddle Pipe (Black Colour) , 1.5 Inch Saddle Pipe (Black Colour) , 2 Inch-1.25 Inch Nozzle (Moter) , 2 Inch - 1.5 Inch Nozzle (Moter) , 1.5 Inch - 1.5 Inch Nozzle (Moter) , 1.25 Inch - 1.25 Inch Nozzle (Moter) , 1.25 Inch - 1 Inch Nozzle (Moter) , 1.5 -Inch - 1 Inch Nozzle (Moter) , Pipe Pana Tapariya (12 No.) , Pipe Pana Tapariya (10 No.) , 1 Inch Pvc Pipe & ( Elbow, Soket, T, Volve, End Cap) , 1. 3/4 Poun Inch Pvc Pipe ( Elbow, Soket, T, Volve, End Cap) , 1/2 Inch Pvc Pipe ( Elbow, Soket, T, Volve, End Cap) , 2 Inch Nut, Bolt 21 Number , 4 Inch Nut, Bolt 21 Number , 3 Inch Nut, Bolt 21 Number , Putti + Sutli (White Colour) , Petchcus Tapariya , Tester Tapariya , 1.25 Inch - 1 Inch Reducer , 1.5 Inch - 1 Inch Reducer , 1.25 Inch - 1. 3/4 Inch Reducer , Hammer Bigger , Ring Pana 18 No. , Hexa Blade With Frame (Small) , Pvc Saddle Clamp 1.25 Inch With Nut Bolt Saddle , Pvc Saddle Clamp 1.5 Inch With Nut Bolt Saddle , Pvc Saddle Clamp 1 Inch , Pipe Ring Clamp Hose 1.25 Inch , Pipe Ring Clamp Hose 1.5 Inch , Pipe Ring Clamp Hose 2 Inch , 1 Inch - 1/2 Inch Pvc T , Gate Valve Pvc 1 Inch , 6 Inch Of 21 No. Nut-Bolt , Patti Clamp 2 Inch , Sluice Valve 4 Inch Cast Iron With Paking (6Mm- 4Mm) , Sluice Valve 3 Inch Cast Iron With Paking (6Mm- 4Mm) , Sluice Valve 2 Inch Cast Iron With Paking (6Mm- 4Mm) , Gallon Dori 4Mm , Gallon Dori 6Mm , Pvc Gate Valve 1.5 Inch , Ring Rubber D Joint (3 Inch, 4 Inch) , Pvc Pipe 1 Inch , Pvc Pipe 1. 3/4 Inch , Gate Valve 3 Inch (4 Hole) , Gate Valve 4 Inch , Gate Valve 2 Inch , Connection Clamp 1 Inch , Pvc Pipe 1. 3/4 Inch Nut-Bolt With Connection , Saddle Clamp 1. 3/4 Inch Nut-Bolt With Connection , Saddle Ring Clamp 1. 3/4 Inch With Nut-Bolt , Saddle Clamp Pvc 1 Inch Connection Clamp With Nut-Bolt , Pvc 1 Inch (T, Elbow, Soket, ) All , Pvc 1. 3/4 Inch Valve , Pvc 1 Inch Valve , Pvc 1.5 Inch Valve , Pvc 1.5 Inch (T, Elbow, Soket, ) All , Gun Mattle Valve 2 Inch , 6 Inch Valve , Coolent (Green)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Madhya Pradesh View Result →
11.
Defence #11200251 Technical Bid
Tender For Provision Of Certain Sanctioned Works Under Ge South Bathinda At Bathinda Mil Stn.- 1 Surface Excavation N.Exc (Not Exceeding) 30 Cm Deep And Averaging 15Cm Deep And Getting Out And Getting Out In Soft / Loose Soil Complete All As Specified & Directed. 2 Removing Excavated Material Exc 1.50 Km N Exc. 5 Km And Depositing Where Directed At A Level N Exc. 1.5 M Above The Starting Point Complete All As Specified And As Directed. 3 Excavation In Trenches Not Exceeding 1.5 Meter Wide And Not Exceeding 1.5 Meter Depth For Foundation Etc Or For Shafts , Wells, Cesspits, Manholes , Septic Tank, For Laying Of Cables , Laying Of Pipes Not Exceeding 10 Sqm On Plan And Not Exc 1.5 Meter Depth And Getting Out In Soft/Loose Soil Etc Complete All As Specified And As Directed By Engineer-In- Charge. 4 Material And Labour For Cement Concrete 1:4:8 , Type D-2 Using 40 Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 5 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Foundations, Including Rafts, Footings, Foundation Beams; Plinth Beams; Bases For Columns, Etc.; Basement Slabs, Under-Reamed Piles And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 6 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Columns, Pillars, Piers, Posts And Struts Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 7 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Beams, Cantilevers, Bressummers, Lintels Over 1.5 M Span And The Like Etc Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 8 Material And Labour For Rcc M-25 (Design Mix) Using 20Mm Graded Stone Aggregate As In Slabs Supported On Walls, Beams And Columns In Floors,Roofs, Landings, Balconies,Canopies, Deck Slabs And In Shelves And The Like Complete All As Specified And As Directed By Engineer-In-Charge.Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 9 Material And Labour For Formwork Of Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits (If Any) Of Foundation And Plinth Beams; And Similar Work; Vertical Or To Batter On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 10 Material And Labour For Formwork In Square,Reactangular Or Polygonal On Rough Finished Surface Of Concrete To Sides Of Pillars, Posts, Struts, Piers, Columns And Stanchions Complete All As Specified And As Directed By Engineer-In-Charge. 11 Material And Labour For Formwork To Sides And Soffits Of Floor Or Roof Beams, Beam Haunchings, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc. Also Splays Between Floors And Beams, Etc. On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 12 Material And Labour For Formwork To Soffits Of Suspended Slabs Such As Roof Slab, Floor Slabs, Landings And Similar Work Not Exceeding 200 Mm Thick (Horizontal Or Sloping) On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 13 Material And Labour For Formwork To Edges Of Concrete Flats, Treads, Breaks In Floors,Window Cills, Concrete Rail Ings, Openings In Concrete Walls, Floor And Roofs Not Exceeding 20Cm Wide And Sides Of Rcc/Pcc Bands In Walls, Horizontal Or Sloping And Similar Work Exceeding 10 Cm But Not Exceeding 20Cm Wide On Rough Finished Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 14 Material And Labour For Mild Steel Tmt Bars 10Mm Dia And Over Cut To Length Bent To Shape, Required Including Cranking, Bending Spirally For Hoping For Columns, Hooking Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Including Making Of Rungs, Handles Etc Complete All As Specified And As Directed By Engineer-In-Charge. (Note : Weight Of Binding Wire Shall Not Be Considered For Measurement And Payment Purpose.) 15 Material And Labour For Mild Steel Tmt Bars 6Mm To 8Mm Dia Cut To Length Bent To Shape, Required Including Cranking, Bending Spirally For Hoping For Columns, Hooking Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Including Making Of Rungs, Handles Etc Complete All As Specified And As Directed By Engineer-In-Charge. (Note : Weight Of Binding Wire Shall Not Be Considered For Measurement And Payment Purpose.) 16 Demolition Of Brick Work Or Stone / Boulder Masonry, Built In Cement Mortar Or Cement Lime Mortar Including All Quoins, Arches, Pillars, Etc, In Any Description Complete All As Specified And As Directed By Engineer-In-Charge. 17 Material And Labour For Brick Work With Sub Class ‘B’ Bricks Straight Or Curved On Plan Exceeding 6.0M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And As Directed By Engineer-In-Charge. 18 Material And Labour For Brick Work With Fly Ash Bricks Straight Or Curved On Plan Exceeding 6.0M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And As Directed By Engineer-In-Charge. 19 Material And Labour Brick Work With Sub Class ‘B’ Old Size Burnt Clay Bricks Straight Or Curved On Plan Exceeding 6 Metre Mean Radius Built In Cement Mortar 1:6, Complete All As Specified And As Directed By Engineer-In-Charge . 20 Material And Labour For Brick Work With Fly Ash Old Size Bricks, Straight Or Curved On Plan To Any Radius In Half Brick Walls Built In Cement Mortar 1:4 Complete All As Specified And As Directed By Engineer-In-Charge. 21 Demolition Of Cement Concrete (Unreinforced) In Ground Floor And Paving Not Exceeding 15Cm Thickness Below Or Above Ground Level Of Any Description And In Any Position Including Removing Rubbish Material From Building And Thrown In Low Lying Empty Area (As Per Direcction Of Age/Je) At Any Distance Upto 500 Metres From The Site Complete All As Specified And As Directed By Engineer-In-Charge 22 Material & Labour For Cement Concrete 1:3:6 Type C-2 Using 40 Mm Graded Stone Aggregate For Foundations, Fillings & Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 23 Material And Labour For Cement Concrete (1:5:10), Type E-2 Using 40 Mm Graded Stone Aggregate As In Filling Of Sunken Floors Complete All As Specified And As Directed By Engineer-In-Charge. 24 Demolition Of Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided Complete All As Specified And Directed. 25 Material And Labour For Waterproofing Treatment To Sunken Floor Using Acrylic Based Multipurpose Polymer. The Treatment Shall Be Carried Out As Per Manufactures Specification. The Treatment Shall Be Include Of The Following Elements Also: 1. Surface Preparation Of Substrate By Removing All Traces Of Contaminates, Loose And Friable Particles, Cement Laitance Oils And Grease, Water Repellent Coatings Etc2. Injection Grouting Using Cementitious Grout If Required. The Payment For Injection Grouting Shall Be Made Separately Etc3. Repair To The Substrate, Filling Of Blow Holes/Voids And Surface Leveling Using Appropriate Products Specified By The Manufacture.4. All Intersections Of Horizontal And Vertical Surface Should Be Profiled With A Mortar Fillet Of Minimum 25Mm X 25Mm.5. The Moisture Content Of The Substrate Shall Be Checked Before Application Of First Coat At Water Proof Coating At The Rate Of 200 G/M2 Followed Brush Topping At 450G/M2 Per Mm. The Second Coat Shall Be Reinforced With Glass Fabric Between The First And Second Coat.6. The Treatment Shall Be Protected By Application Of Polymer Modified Cement Mortar Of Thickness 10Mm Applied At The Rate Of 50G Per Mm.7. Tech Specification : Tensile Adhesion Strength 0.5N/Sqmm (As Bonding Slurry). 26 Material And Labour For Aerated Autoclaved Concrete (Aac) Blocks Work According To Indian Standard Specification Is:2185(Part-3)-1984 And Latest Revision Built In Cement And Sand Mortar 1:6 With Aerated Autoclaved Concrete (Aac) Blocks Straight Or Curver On Plan Exceeding 6Mtr Mean Radius As In Sunken Floor Complete All As Specified And And As Directed By Engineer-In-Charge. 27 Supply Only Integral Water Proofing Compound. 28 Removing Excavated Material As In All Kind Of Soils Not Exceeding 50M And Depositing Where Directed At A Level Not Exceeding 1.5M Above The Starting Point Complete All As Specified And As Directed By Engineer-In- Charge. 29 Returning Filling In Any Type Of Soil, Including Spreading, Levelling,Watering And Well Ramming In Layer Not Exceeding 25 Cm In Each Layer, Complete All As Specified And As Directed By Engineer-In- Charge. 30 Material And Labour For Sand Filling Under Floor Or In Foundation Including Spreading Levelling, Watering And Well Ramming In Layers Not Exc 25 Cmetc Complete All As Specified And As Directed By Engineer-In- Charge. Note: Sand Shall Be Approved By Ge. 31 Material And Labour For Hard Core Using Broken Stone Aggregate Of Gauge Not Exc. 63Mm, Deposited Spread And Leveled In Layers Not Exc. 150 Mm Thick, Watered And Rammed To A True Surface Complete All As Specified And As Directed By Engineer-In- Charge. 32 Material And Labour For 75 Mm Thick Cement Concrete 1:4:8 , Type D-2 Using 40 Mm Graded Stone Aggregate As In Sub Base Of Floor. Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 33 Material And Labour For Rendering 10 Mm Thick In Cement Mortar 1:6 On Fair Faces Of Brick Work Or Concrete Surfaces Of Walls And Finishing The Surface Even & Fair Faces Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 34 Material And Labour For Rendering 5 Mm Thick In Cement Mortar In (1:3) On Ceiling And Finishing The Surface Even & Smooth Without Using Extra Cement Complete All As Specified And Directed. 35 Material And Labour For 15Mm Thick Rendering In Cement Mortar 1:4 On Fair Faces Of Brick Work Or Concrete Surfaces Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 36 Material And Labour For 15Mm Thick Rendering In Cement Mortar 1:4 On Fair Faces Of Brick Work Or Concrete Surfaces And Finishing Fair & Even Mixed With Liquid Water Proofing Compound As Per ManufacturerS Instructions But Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. Note :- Liquid Water Proofing Compound Shall Be Measured And Paid Separately. 37 Supply And Fixing Chicken Wire Mesh ( Murga Jali ) In Cement Plaster Or Over Joints Of R.C.C And Brickwork Or As Per Site Requirement Of 24 Gauge & 12 Mm Mesh And 300 Mm Width For Construction Joints And Chasing In Brick Work For Electrical Conduits Or Water Supply Pipes And Pegs/Nails With Nailing Machine As Required Before Rendering / Plastering Etc. Complete As Per Site Requirement Complete All As Specified And As Directed By Engineer-In- Charge.Note: Rendering / Plastering Shall Be Measured And Paid Seperately Under Serial Item No. 5.00 Of ScheduleA Boq Here-In- Before. Nothing Shall Be Paid Extra On Account Of Rendering / Plastering In This Item. 38 Material And Labour For Applying Acrylic Wall Care Putty On Internal Surfaces And External Surfaces Of Walls/Ceilings/Soffits (Thickness Vary From 1.5 To 2.5 Mm As Required For Desired Smoothness And Leveling Of Surfaces In Two Or More Layers) By Using Ready Made Acrylic Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc Complete All As Specified And Directed By Engineer-In- Charge.Make Of Acrylic Wall Care Putty : As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After.Notes : (I) The Prepared Surface After Wall Putty, The Contractor Will Inform To The Ge As Well As To The Engineer-In-Charge For Site Inspection Before Applying Further Finishes. Please Note That The Further Finishes Work Will Start Only After Approval Of The Prepared Surface From The Ge As Well As To The Engineer-In-Charge Through Site Order. (Ii)The Make Of Acrylic Wall Care Putty Shall Be As Per The Recommendation Of Manufacturer Of Paint. 39 Material And Labour For Preparation Of New Surfaces And Applying 02 Coats Of Interior Acrylic Emulsion Paint (Light Shade As Approved By Ge ) @ 10.00 Sq.M/ Litre / 2.00 Coats By Using Roller/Brush To Wall Surfaces Over With And Including One Coat Of Interior Acrylic Emulsion Primer @ 10.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Interior Acrylic Emulsion By Using The Brands Of Interior Acrylic Emulsion Paint And Interior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 40 Material And Labour For Complete Removal Of Existing Treatment Of Any Type / Description From Wall / Rcc Surfaces / Ceiling / Chajjas / Roof Projections Etc With Mechanical Means / Grinder And Applying 01 Coat Of Exterior Emulsion Paint (Light Shade) With Highlighter Of Any Existing Shade @ 10 Sqm/Litre/1 Coat By Using Roller To External Walls / Rcc Surfaces/Soffits Of Chajjas / Roof Projections /Cantilevers/ Balcony Etc Surfaces Over Acrylic Thick Wall Care Putty On External Surfaces Of Walls / Ceiling / Soffits ( Thickness Vary From 1.5 To 2.5Mm As Required For Desired Smoothness And Levelling Of Surfaces In Two Or More Layers) By Using Ready Made Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc, Over Including A Coat Of Exterior Wall Primer @ 10 Sqm/Litre/1 Coat As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Including Removing The Vegetation Of Any Type And Description The Making The Surface Good Complete All As Specified And Directed. 41 Material And Labour For Preparation Of Old Surfaces And Applying 02 Coats Of Interior Acrylic Emulsion Paint (Light Shade As Approved By Ge ) @ 10.00 Sq.M/ Litre / 2.00 Coats By Using Roller/Brush To Wall Surfaces Over With And Including One Coat Of Interior Acrylic Emulsion Primer @ 10.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Interior Acrylic Emulsion By Using The Brands Of Interior Acrylic Emulsion Paint And Interior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 42 M&L For Preparing Existing Treated Surfaces Of Ceiling Including Cornices And Applying Two Coats Of White Wash By Making The Lime Slaked At Site And Shall Be Mixed And Stirred With About Five Liters Of Water For 1 Kg Of Unslaked Lime To Make A Thin Cream. This Shall Be Allowed To Stand For A Period Of 24 Hours And Shall Then Be Screened Through Clean Coarse Cloth. 1 Kg Of Gum Dissolved In Hot Water Shall Be Added To Every One Cubic Meter Of Lime Cream. About 1.3 Kg Of Sodium Chloride Dissolved In Hot Water Shall Also Be Added For Every 10 Kg Of Lime For Making The Coating Hard And Rub-Resistant. Small Quantity Of Ultramarine Blue (Upto 3 Gm Per Kg Of Lime) Shall Also Be Added To The White Wash Solution And The Whole Solution Shall Be Stirred Thoroughly Before Use Complete All As Specified And As Directed By Engineer-In-Charge. 43 Material And Labour For Preparation Of New Surfaces And Applying 02 Coats Of Exterior Acrylic Emulsion Paint ( Shade As Approved By Ge) With Highlighter Of Any Approved Shade, @ 5.00 Sq.M / Litre / 2.00 Coats By Using Roller To External Walls / Rcc Surfaces / Soffits Of Chajjas / Roof Projections / Cantilevers / Balcony Etc. Surfaces Over With And Including One Coat Of Exterior Acrylic Emulsion Primer @ 11.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Exterior Acrylic Emulsion By Using The Brands Of Exterior Acrylic Emulsion Paint And Exterior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 44 Material & Labour For Applying Two Or More Coats Of 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Interior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives @ 1.43 Litre/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/ 10 Sqm Including A Coat Of Exterior Wall Primer @ 11 Sq.M/Litre/1 Coat As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Complete All As Specified And Directed. 45 Material And Labour For Preparation Of Old Surfaces And Applying 02 Coats Of Exterior Acrylic Emulsion Paint ( Shade As Approved By Ge) With Highlighter Of Any Approved Shade, @ 5.00 Sq.M / Litre / 2.00 Coats By Using Roller To External Walls / Rcc Surfaces / Soffits Of Chajjas / Roof Projections / Cantilevers / Balcony Etc. Surfaces Over With And Including One Coat Of Exterior Acrylic Emulsion Primer @ 11.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Exterior Acrylic Emulsion By Using The Brands Of Exterior Acrylic Emulsion Paint And Exterior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 46 Material And Labour For Complete Removal Of Existing Treatment Of Any Type / Description From Wall / Rcc Surfaces / Ceiling / Chajjas / Roof Projections Etc With Mechanical Means / Grinder And Applying One Coat Of Exterior Emulsion Paint (Light Shade) With Highlighter Of Any Approved Shade @ 5 Sqm/Litre/2 Coats By Using Roller To External Walls / Rcc Surfaces/Soffits Of Chajjas / Roof Projections /Cantilevers/ Balcony Etc Surfaces Over & Including A Coat Of Exterior Wall Primer @ 11 Sqm/Litre/1 Coat Over Acrylic Thick Wall Care Putty On External Surfaces Of Walls / Ceiling / Soffits (Thickness Vary From 1.5 To 2.5Mm As Required For Desired Smoothness And Levelling Of Surfaces In Two Or More Layers) By Using Ready Made Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Complete All As Specified And Directed.Note For Item No 5 To 8 :- (A) The Prepared Surface After Wall Putty, The Contractor Will Inform To The Ge As Well As To The Engineer-In-Charge For Site Inspection Before Applying Further Finishes. Please Note That The Further Finishes Work Will Start Only After Approval Of The Prepared Surface From The Ge As Well As To The Engineer-In-Charge Through Site Order. 47 Material And Labour For For Preparing New Plastered Surfaces Of Ceilings And Applying Three Coats Of White Wash By Making The Lime Slaked At Site And Shall Be Mixed And Stirred With About Five Liters Of Water For 1 Kg Of Unslaked Lime To Make A Thin Cream. This Shall Be Allowed To Stand For A Period Of 24 Hours And Shall Then Be Screened Through Clean Coarse Cloth. 1 Kg Of Gum Dissolved In Hot Water Shall Be Added To Every One Cubic Meter Of Lime Cream. About 1.3 Kg Of Sodium Chloride Dissolved In Hot Water Shall Also Be Added For Every 10 Kg Of Lime For Making The Coating Hard And Rub-Resistant. Small Quantity Of Ultramarine Blue (Upto 3 Gm Per Kg Of Lime) Shall Also Be Added To The Last Two Coats Of White Wash Solution And The Whole Solution Shall Be Stirred Thoroughly Before Use Complete All As Specified And Directed By Engineer-In- Charge. 48 Material And Labour For Applying Three Coats Of White Wash On Newly Plastered Or Unplastered Ceiling Surfaces Including Preparation Of Surfaces, Complete All As Specified And Directed 49 Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frames) Area Not Exc 1.5 Sqm Each As Doors, Windows And Ventilators And Removal From Site Complete All As Specified And Directed. 50 Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frame) Exc 1.5 Sqm But Not Exc 4 Sqm Each Each As Doors, Windows And Ventilators And Removal From Site Complete All As Specified And Directed. 51 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door Frame / Chowkhat Of Size 45Mm X 70 Mm Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvant Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg /Cum And Screw Withdrawl Strength Of 2200 N (Face ) & 1100 N (Edge) Minimum Compressive Strength Of 58 N /Sqmm Modulus Of Elasticity 900 N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retaident And Fixed In Position With And Including Ms Hold Fast Lugs / Ss Dash Fastner Of Required Dia And Length With And Including Supply And Fixing (03 Nos Per Frame ) 100 Mm Long Ss Butt Hinges Complete All As Specified And As Directed By Engineer-In- Charge. 52 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door Frame / Chowkhat With Double Rebate Of Size 65Mm X 125 Mm Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvant Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg /Cum And Screw Withdrawl Strength Of 2200 N (Face ) & 1100 N (Edge) Minimum Compressive Strength Of 58 N /Sqmm Modulus Of Elasticity 900 N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retaident And Fixed In Position With And Including Ms Hold Fast Lugs / Ss Dash Fastner Of Required Dia And Length With And Including Supply And Fixing (03 Nos Per Frame ) 100 Mm Long Ss Butt Hinges Complete All As Specified And As Directed By Engineer-In- Charge. 53 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Plain Flush Door Shutter Of 30 Mm Thick , Size Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Having Minimum Density Of 650 Kg /Cum And Screw Withdrawl Strength Of 1800 N (Face ) & 900 N (Edge) Minimum Compressive Strength Of 50 N /Sqmm Modulus Of Elasticity 850N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retardant And With And Including Supply & Fixing Of 02 Nos (Per Leaf) Ss 150Mm Long Tower Bolt, Supply & Fixing Of 02 Nos (Per Door) Ss 300Mm Long Sliding Bolt With And Including Supply & Fixing Of 02 Nos (Per Leaf) Stainless Steel 150Mm Long Handle Complete All Specified And Directed By Engineer -In-Charge. 54 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Decorative Flush Door Shutter Of 30 Mm Thick , Size Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Having Minimum Density Of 650 Kg /Cum And Screw Withdrawl Strength Of 1800 N (Face ) & 900 N (Edge) Minimum Compressive Strength Of 50 N /Sqmm Modulus Of Elasticity 850N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retardant And With And Including Supply & Fixing Of 02 Nos (Per Leaf) Ss 150Mm Long Tower Bolt, Supply & Fixing Of 02 Nos (Per Door) Ss 300Mm Long Sliding Bolt With And Including Supply & Fixing Of 02 Nos (Per Leaf) Stainless Steel 150Mm Long Handle Complete All Specified And Directed By Engineer -In-Charge. 55 Supply & Fixing Factory Made 30Mm Thick Solid Wpc ( Wood Polymer Composite ) Wiremesh Door Shutter Of Required Size Comprising Of Virgin Pvc Resin Of K Value 57-60 ( Suspension Rade ), Calcium Carbonate And Natural Fibers ( Wood Powders/ Rice Husk/ Wheat Husk ) And Non Toxic Additives, Made From Extrusion Process Wpc Foam Sheet Single Extruded ( Inner ) With Having Minimum Density Not Less Than 650 Kg/Cum , Having Good Screw Holding Capacity ( Screw Withdrawal Strength Of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compressive Of 50 N/Mm2, Modulus Of Elasticity 850N/Mm2 And Resistance Of Spread Of Flame Of Class A Category With Property Of Being Termite/ Borer Free.Water/ Moisture Proof And Fire Retardant. Pvc Foil Of Minimum 14 Microns Thick Of Approved Design Pasted On Both Faces Of Shutter For Fixing Mosquito Mesh And Xtn Aluminium Mesh Together On Panel Area Of Door Except Stiles And Rails To Be Panelled With And Including Mesh With Self Tapping Round Headed Scresws At Required Distance, Screws And Edges Covered With Feathered Pvc Edge Beading All Around Of Mesh And Fixing Stainless Steel Butt Hinges Of Required Size With Necessary Full Body Threaded Star Headed Counter Sunk Ss Screws With And Including 03 Nos Door Stainless Steel Butt Hings 100Mm Long With Stainlessd Steel Screws For Each , 02 Nos Stainless Steel Barrel Tower Bolts Of Extrude Section, 150Mm Long (Isi Marked), 2 Nos Stainles Steel Handles, 125 Mm Long, (Isi Marked) , 01 No. Of Helical Door Spring Of 300 Mm Length Complete All As Specified And As Directed By Engineer-In-Charge. Note: 1. Material Test Certificate Of All The Items And Authentication Should Be Compulsory Provided By The Manufacturing Company 2. The Rate Of 03 Nos Door Stainless Steel Butt Hings 100Mm Long With Stainlessd Steel Screws For Each , 02 Nos Stainless Steel Barrel Tower Bolts Of Extrude Section, 150Mm Long (Isi Marked), 2 Nos Stainles Steel Handles, 125 Mm Long, (Isi Marked) , 01No. Of Helical Door Spring Of 300 Mm Length Is Inclusive In This Item And Nothing Shall Be Paid Extra On This Item..3. The Rate Of Mosquito Mesh And Xtn Aluminium Mesh Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 56 Supply And Fixing Factory Made Upvc White Colour Casement (Openable) Window (Area Exceeding 1.00 Sqm But Not Exceeding 2.00 Sqm Each) Made Of Extruded Profiles With Wall Thickness Of 2.3Mm ( + – 0.2Mm). Window Profile With Hollow Section With Multi Chamber, Frame (60Mm X 58Mm), Sash (60Mm X 73Mm), T Profile (One Vertical Length In Between Two Shutters) (60Mm X 74Mm), Glazing Bead (35Mm X 20Mm) Will Be Mitered Cut And Fusion Welded At All Corners, Including Drilling Of Holes For Fixing Hardware And Drainage Of Water Etc., Making Arrangement For Fixing Of Hardware. Epdm Gasket 1.2 +– 0.2Mm Thick, Galvanized Steel Frame (28Mm X 21.5Mm), Sash (31Mm X 27.5Mm). T Profile (27Mm X 17Mm) To Be Inserted In Required Profile, Frame Will Be Fixed To The Wall With 8 Mm X 100Mm Long Fasteners. Hardware: [Casement Handle Made Of Zinc Alloyed (White Powder Coated), But Hinges OfZinc Alloyed (White Powder Coated), Transmission Gear Made Of Mild Steel With Multi Point Locking System] And 5Mm Thick Glazing With Selected Quality Glass.(Note: The Unit Rate Quoted By Contractor Excludes Cost Of Glass And Includes All Other Connected Accessories. Net Opening Will Be Measured For Payment Purpose.) 57 Material And Labour For 75 Mm Thick Pcc 1:3:6 , Type C-1 Using 20 Mm Graded Stone Aggregate As In Plinth Protection, Finishing The Surface Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 58 Material And Labour For 75 Mm Thick Pcc 1:3:6 , Type C-2 Using 40 Mm Graded Stone Aggregate As In Plinth Protection, Finishing The Surface Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 59 Demolition And Breaking Up Drain Pipes (Salt Glazed Ware, Ac Or Reinforced Concrete)Of Any Dia Set In Cement Laid In Trenches Incl All Fittings & Accessorises Complete All As Specified And As Directed By Engineer-In- Charge. 60 Supply & Fixing For 4 Mm Thick, Sheet Glass Ordinary Quality And Glazing With Oil Putty In Square Not Exceeding 0.5 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 61 Supply & Fixing 4.0 Mm Thick Figured Glass Pin Head Type And Glazing With Oil Putty In Square N.Exc 0.5 Sqm In Each Pane Complete All As Specified And Directed 62 Supply & Fixing 5.5 Mm Thick, Sheet Glass Ordinary Quality Not Exceeding 0.50 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 63 Supply & Fixing 5.5 Mm Thick, Sheet Glass Ordinary Quality Exceeding 0.50 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 64 Material And Labour For Providing And Fixing Aluminium Work With Polyester Powder Coated Aluminium ( Minimum Thickness Of Polyester Powder Coating 50 Micron For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/Appropriate Z Sections And Other Sections Of Approved Make Conformikng To Is:733 And Is :1285, Fixing With Dash Fasteners Of Required Dia And Size,Including Necessary Filling Up The Gaps At Junctions I.E At Top , Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth , Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Aluminium Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling , C.P. Brass/ Stainless Steel Screws, All Complete All As Specified And Directed By Engineer-In-Charge .Note :- (I) Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading Shall Be Physically Ascertained Through A Board Of Officers Convened By Ge And Payment Shall Be Made Only After Ascertaining The Actual Weight Of Aluminium At Site.(Ii) The Rate Of Material And Labour For Providing The Epdm Rubber, Neoprene Gasket , C.P. Brass / Stainless Steel Screws Are Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) During Considering The Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading , The Weight Of Epdm Rubber, Neoprene Gasket , C.P. Brass/ Stainless Steel Screws Shall Not Be Considered For Measurments And Payments. Only The Weight Of The Aluminium Sections , Aluminium Cleat Angles, Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading Shall Be Considered And Measurment And Payment Shall Be Made Accourdingly.(Iv) During The Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading ,The Weight Of Polyester Powder Coating 50 Micron Shall Not Be Considered For Weight But The Rate Of Material And Labour For Providing Polyester Powder Coating 50 Micron Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (V) Glazing /Paneling And Wire Mesh Shall Be Measured And Paid Seperately. (V)The Board Shall Be Duly Countersigned By Ge Shall Enclosed With Final Bill . 65 Supply & Fixing Stainless Steel Wire Cloth 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.4Mm And Fixed With Tinned Tacks To Stainless Steel Wire Staple Complete All As Specified And As Directed By Engineer-In-Charge. 66 Supply & Fixing Galvanised Ms Wire Cloth 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.4Mm And Fixed With Tinned Tacks To Galvanised Ms Wire Staple Complete All As Specified And As Directed By Engineer-In-Charge. 67 Material And Labour For Providing And Laying Premium (1St Quality) Straight Edge,Stain Free, Glooss Finish, Square Marbonite Double Charged Vitrified Tiles Size In 600Mm X 600Mm X 9Mm To 10Mm Thick As In Floors Etc. Shade As Approved By Ge , Set And Jointed With Using Spacer And Approved High Polymer Modified, Grey Cement-Based Tile Adhesive Suitable For Fixing Medium Format Tile/Stone In Walls/Floor Conforms To Is 15477 : 2019 Type 2T “Adhesives For Use With Ceramic, Mosaic And Stone Tiles” Conforms To En 12004: 2017 And Is A Normal Cementitious Adhesives (C1) With Slip Resistance (T) Of Class C1 And Necessary Grouting As Per Manufacturer’S Instruction, Completed All As Specified And Directed By Engineer-In-Charge. 68 Supply And Fixing Anodised Aluminium Snap Grid Frame Work For False Ceiling 605Mm X 605 Mm Etc Complete All As Specified And As Directed By Engineer-In-Charge. 69 Supply And Fixing False Ceiling At All Heights With Grg (Glass Fibre With Reinforced Gypsum) False Ceiling Tiles Of Size 595 X 595 Mm Of Approved Tecture Design And Patterns Having Moisture Content Less Than 2% Humidity Resistance Of 99%, Nrc 0.50 To 0.75 As Per Is 8225:1987, Noncombustible As Per Bs 476 (Part 4)- 1970 And Light Reflectance Of 85%D (Minimum) To Be Laid In True Horizontal Level Suspended On Inter Locking Metal T-Grid Of Hot Dipped Galvanisezed Iron Section Of 0.33Mm Thick (Galvanized @ 120 Grams Per Sqm Including Both Sides) Comprising Of Main T Runners Of Size 15 X 32 Mm Of Length 3000 Mm, Cross-T Of Size 15 X 32Mm Of Length 1200Mm And Secondary Intermediate Cross T Of Size 15 X 32 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600Mm, Suspended From Ceiling Using Galvanised Mild Steel Items (Galvanizing @ 80 Grams Per Sqm) I.E 50 Mm Long, 8 Mm Outer Diameter M-6 Dash Fasteners, 6Mm Dia Fully Threaded Hanger Rod Upto 1000 Mm Length And L Shape Level Adjuster Of Size 85 X 25 X 2Mm. Galvanized Iron Perimeter Wall Angle Of Size 24 X 24 X 0.40Mm Of Length 3000 Mm To Be Fixed On Periphery Wall I Partition With Help Of Plastic Rawl Plugs At 450 Tiles Fully Center To Center And 40Mm Long Dry Wall Wodd Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-In-Charge. 70 Material And Labour Anodised Aluminium Frame For Doors, Windows, Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc. Omplete All As Specified And As Directed By Engineer-In-Charge. 71 Material And Labour For Providing And Fixing Aluminium Work With Polyester Powder Coated Aluminium ( Minimum Thickness Of Polyester Powder Coating 50 Micron For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/Appropriate Z Sections And Other Sections Of Approved Make Conformikng To Is:733 And Is :1285, Fixing With Dash Fasteners Of Required Dia And Size,Including Necessary Filling Up The Gaps At Junctions I.E At Top , Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth , Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Aluminium Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling , C.P. Brass/ Stainless Steel Screws, All Complete All As Specified And Directed By Engineer-In-Charge .Note :- (I) Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading Shall Be Physically Ascertained Through A Board Of Officers Convened By Ge And Payment Shall Be Made Only After Ascertaining The Actual Weight Of Aluminium At Site.(Ii) The Rate Of Material And Labour For Providing The Epdm Rubber, Neoprene Gasket , C.P. Brass / Stainless Steel Screws Are Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) During Considering The Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading , The Weight Of Epdm Rubber, Neoprene Gasket , C.P. Brass/ Stainless Steel Screws Shall Not Be Considered For Measurments And Payments. Only The Weight Of The Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading Shall Be Considered And Measurment And Payment Shall Be Made Accordingly.(Iv) During The Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading ,The Weight Of Polyester Powder Coating 50 Micron Shall Not Be Considered For Weight But The Rate Of Material And Labour For Providing Polyester Powder Coating 50 Micron Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (V) Powder Coated Butt Hinges, Aluminium Handles, Aluminium Tower Bolts & Aluminium Peg Stays Shall Be Measured And Paid Seperately Under Respective Itmes Of ScheduleA Boq.(V) Glazing /Paneling And Wire Mesh Shall Be Measured And Paid Seperately. (Vi)The Board Shall Be Duly Countersigned By Ge Shall Enclosed With Final Bill 72 Material And Labour Anodised Aluminium Grill (Anodised Transparent Of Dyed To Required Shade According To Is: 1868 With Minimum Anodic Coating Of Grade Ac 15) Of Approved Design/Pattern, With Approved Standard Section And Fixed To The Existing Window Frame With C.P. Brass/Stainless Steel Screws @ 200 Mm Centre To Centre, Including Cutting The Grill To Proper Opening Size For Fixing And Operation Of Handles And Fixing Approved Anodised Aluminium Standard Section Around The Opening, All Complete As Per Requirement And Direction Of Engineer-In-Charge. 73 Taking Up Or Down Galvanised Steel Water Tubing (Gi Pipe) 15Mm Bore Including Fitting/Connection From Wall/Ceiling/Floor/Concealed Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 74 Taking Up Or Down Galvanised Steel Water Tubing (Gi Pipe) 20Mm Bore Including Fitting/Connection From Wall/Ceiling/Floor/Concealed Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 75 Supply And Fixing 16 Mm Bore Cpvc Pipe Sdr 11 With And Including Cpvc Sdr 11 Fittings And Fixed To Walls & Ceilings Or Laid In Floors, Complete Complete All As Specified And As Directed By Engineer-In-Charge 76 Supply And Fixing 20 Mm Bore Cpvc Pipe Sdr 11And Plain Cpvc Sdr 11 Fitting With All Fitting And Fixed To Walls & Ceilings Or Laid In Floors, Including Taking Down Unservicable Existing Gi Tubing Of 20Mm Bore And Fittings Complete Complete All As Specified And As Directed By Engineer-In-Charge. 77 Supply And Fixing 25 Mm Bore Cpvc Pipe Sdr 11And Plain Cpvc Sdr 11 Fitting With All Fitting And Fixed To Walls & Ceilings Or Laid In Floors, Including Taking Down Unservicable Existing Gi Tubing Of 20Mm Bore And Fittings Complete Complete All As Specified And As Directed By Engineer-In-Charge. 78 Material And Labour For Cutting Chases In Brick Wall , Pinning In. Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 Or Pcc 1:2:4 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; And Cutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Etc., And Making Good, Cutting Exc 10 Cm But Not Exc 20 Cm Girth Complete All As Specified And As Directed By Engineer-In- Charge.. 79 Supply And Fixing In Repair Brass Chromium Plated Wall Mixer For Mixing Hot & Cold Water Screwed Down, Screwed For 15Mm Bore Pipe Or For Brass Ferrule Complete All As Specified And As Directed By Engineer-In-Charge. 80 Supply And Fixing In Repair Bib Taps Cost Copper Alloy With Crutch Or Butterfly Handle , Screwed Down , Chromium Plated Screwed For Iron Pipe Or Brass Ferrul For 15Mm Bore Dia Pipe Complete All As Specified And Director. 81 Supply And Fixing In Reapir 15Mm Bore Bib Tap, Long Body, Fancy Type, Chromium Plated, Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Complete All As Specified And As Directed By Engineer-In-Charge. 82 Supply And Fixing In Repair 15Mm Bore Stop Valves, Fancy Type, Chromium Plated With Long Shank And Cup (Concealed Type) Cast Copper Alloy, Screwed Down, High Pressure, With Crutch Or Butterfly Handle, Screwed Both Ends For Iron Pipe Or For Unions And Fixed For Iron Pipe Or For Brass Ferrule Complete All As Specified & Directed By Engineer-In-Charge. 83 Supply And Fixing In Repair Angular Stop Cock With Wall Flange, Fency Type Chromium Plated Cast Copper Alloy Screwed Down, High Pressure, Screwed One Ends For 15Mm Bore Of Iron Pipe Or For Union And Fixed In Position Complete All As Specified & Directed By Engineer-In-Charge. 84 Supply And Fixing In Repair Vitreous China Wash Hand Basin, White, Flat Back, Size 450Mm X 300 Mm Including Cast Iron Cantilever Bracket With And Including 32 Mm Dia Brass Waste Coupling And With And Including Fixing Of Waste Fitting And Union Complete All As Specified And As Directed By Engineer-In-Charge. 85 Supply And Fixing In Repair Ptmt Mirror Cabinet Of Size 380Mm X 450Mm Best Quality Confirming Ot Sample Kept In GeS Office Complete All As Specified And Directed By Engineer-In-Charge. 86 Supply And Fixing In Replacement Sink With Drainage Board Made Of Stainless Steel 1 Mm Thick Kitchen Or Laboratory With Plugs, Washers And Wastes; Including Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe Overall Size 915Mm X460Mm Bowl Size 410Mm X330Mm X160Mm Complete All As Specified And As Directed By Engineer-In-Charge. 87 Supply & Fixing In Replacement Brass Cp Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe And Fixed For Iron Pipe 15Mm Bore Complete All As Specified And As Directed By Engineer-In-Charge. 88 Supply And Fixing In Repair Stainless Steel Plate Rack Of Size 900Mm X 600Mm X 250Mm And Thickness Of Stainless Steel Strip Of 1Mm Fixed On Wall Etc. Complete All As Specified And Directed . 89 Material And Labour For Cutting Holes In Brick Walls Built In Cement Mortar (Not Exceeding Half Brick) For Inserting Hold Fast And Making Good Dismantled Portion In Cm 1:3 Or Cement Concrete 1 : 2 : 4 , Type B1 As Required , Depth Of Embedded Portion Exceeding Half Brick Walls And Not Exceeding One Brick Of Hold Fast Or Lugs Measured From The Face Of The Jamb Into Walls Complete All As Specified And As Directed By Engineer-In- Charge. 90 Material And Labour For In Repair Vitreous China Wash Down Water Closet Pan Wall Hanging Single Piece (With And Including Flushing Cistern Ewc) P Trap, With And Including White Coloured Closed Pattern Plastic Seat Cover, Hand Faucet , With And Including Mild Steel Chromium Plated Or Aluminised Hinging Device Complete All As Specified And As Directed By Engineer-In- Charge. 91 S & F In Repairs Cp Stainless Steel Grating (With Or Without Waste Hole), 125Mm Size, Fixed On Floor/Nahani Gully Trap Traps Etc Complete All As Specified And Directed. 92 S&F In Repair 25Mm Dia And 1Mm Thick Stainless Steel Drapery Rod Including With Bracket / Wall And Other Side Fancy Knobs At Both Ends As Approved By Engineer-In-Charge/Ge Including Taking Down Old Existing Rod/Pelmet With Accessories Complete All As Specified. 93 Supply And Fixing Cp Brass Fancy Type Corner Glass Shelf (25Cm/30Cm ) With Cp Brass Bracket & Railing Etc. Complete All As Specified And As Directed By Engineer-In- Charge. 94 Supply And Fixing In Repair Stainless Steel, Chromium Plated, Decorative Type, Soap Dish Holder Of Approximate Size 160Mm X 160Mm X 90 Mm Fixed To Wall With Rubber Plugs Complete All As Specified And As Directed By Engineer-In-Charge. 95 Supply & Fixing In Replacement Brass Chromium Plated Tubular Towel Rail 20Mm Dia D Type, 600Mm Long Between Flanges Fixed To Plug , Bracket With Chromium Plated Brass Screws Complete All As Specified And Directed By Engineer-In-Charge. 96 Supply And Fixing 110 Mm Bore Of Pipe Pvc (Swr) Type B Pipes Single Socket 6 Kg/Sq Cm In Any Length With Stack Clamps Made Out Of 50Mm By 5 Mm Flat Iron And 16Mm Dia Round Iron Stays, Including Bolts And Nuts And Securing Ends Of Stays To Wall At A Distance Of 100-120Mm Away From Walls Complete All As Specified And As Directed By Engineer-In- Charge. Including Taking Down Old Ac Eaves Gutters And Rainwater Pipes ( Of Any Size And Pattern), Including All Fittings, Compete All As Specified And As Directed By Engineer - In-Charge. 97 Supply & Fixing 110 Mm Bore Of Pipe Pvc (Swr) Type B Ring Fit Pipes Single Socket In Any Length With Stack Clamps As Shown In Btd Drg No. 916 Sheet 1/4 To 4/4 And Btd-917 Sheet Sheet 1/1 Of Stays To Wall At A Distance Of 100-120Mm Away From Walls Complete All As Specified And As Directed By Engineer-In- Charge Including Taking Down Old Ac Eaves Gutters And Rain Water Pipes ( Of Any Size And Pattern) Including All Fittings, Compete All As Specified And As Directed By Engineer - In-Charge. 98 Dismantling And Disconnecting Of Existing Ci Soil Vent Pipe 100 Mm Bore Fixed To Wall,Laid In Trenches Incl All Fittings & Accessories Complete All As Specified And Directed. 99 Dismantling And Disconnecting Of Existing Ci Soil Vent Pipe 75 Mm Bore Fixed To Wall,Laid In Trenches Incl All Fittings & Accessories Complete All As Specified And Directed. 100 Supply And Fixing 110 Mm Bore, Pvc (Swr) Fittings Type -B Such As Bends, Tee, Shoe Etc; Fixed To Pvc Pipes, Compete All As Specified And As Directed By Engineer - In-Charge. 101 Supply & Fixing 110Mm Bore Pvc (Swr) Pipes Single Socketed In Any Length With Rubber Ring Joints Laid In Trenches Or In Floors Complete All As Specified And As Directed By Engineer-In- Charge. 102 S&F 110 Mm Bore Of Pvc (Swr) Bends And Tee, Type - B Of Any Radius / Shoe With Access Door Fixed To Pvc Pipes Complete All As Specified And Directed. 103 S&F 75 Mm Bore Of Pipe Pvc (Swr) Pipes Type - B Single Socket In Any Length With Rubber Ring Joint Fixed To Walls With Ms Clamps Of F1 25X2Mm Complete All As Specified And Directe 104 S&F 75 Mm Bore Of Pipe Pvc (Swr) Pipes Type - B Double Socket In Any Length With Rubber Ring Joint Fixed To Walls With Ms Clamps Of F1 25X2Mm Complete All As Specified And Directe 105 S&F 75 Mm Bore Of Pvc (Swr) Bends & Tee, Type - B Of Any Radius / Shoe With Access Door Fixed To Pvc Pipes Complete All As Specified And Directed. 106 S&F In Repairs Pvc (Swr) Gully Trap Of Size 150 X 150 Mm, Square Or Round Mouthed, Type P Setting And Jointing With Solvent Cement Complete All As Specified And Directed. 107 Supply And Fixing In Repair Pvc (Swr) Type -B Floor Trap Any Type (Q, S, P), 110/75Mm Dia With Grating Including Jointing To Waste Pipe Fixed In Cement Concrete (1:2:4) Type B-1 Using 20Mm Graded Stone Aggregate Complete All As Specified And Directed By Engineer-In- Charge. 108 Supply And Fixing In Replacement 10 Litres Capacity Pvc Valveless Syphonic Action Type Low Level Flushing Cistern White With Inlet, Ball Valve, Float, Handle Including Brackets And 32Mm Dia Pvc Flush Pipe Complete All As Specified And Directed By Engineer-In-Charge. 109 S&F In Repair Vitreous China Wash Basin, White, Oval Type , Size 450 Mm X 300 Mm Fixed On And Including Cast Iron Cantilever Bracket, 32 Mm Dia Brass Waste Coupling And Including Fixing Of Tap, Waste Fitting And Union Complete All As Specified And Directed. 110 Supply & Fixing In Repair Chromium Plated Square Shower Rose 200Mm X 200Mm Size, With Or Without Swivel Joints, Any Size, Including Fixing To Steel Pipe Or Union For 15Mm Bore Of Pipe Complete All As Specified And As Directed By Engineer-In-Charge. 111 Supply & Fixing In Repair Pvc Connections 15Mm Size With Brass Nuts Of Length 450Mm Complete All As Specified And As Directed By Engineer-In-Charge. 112 Supply & Fixing In Repair Pvc Waste Pipe With Socket Suitable For Connection To Waste Fittings Of 32/40Mm Dia, And Of Length Minimum 75 Cm Complete All As Specified And As Directed By Engineer-In-Charge. 113 Supply And Fixing In Replacement Three Layers 500 Litre Hdpe Water Storage Tanks Polyproof. White In Colour Rotational Moulded Polyethylene (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position Including Supply And Fixing Of Suitable Size Inlet/Outlet Arrangement & Other Accessories Complete All As Specified And As Directed By Engineer-In-Charge. 114 Supply And Fixing In Replacement Three Layers 1000 Litre Hdpe Water Storage Tanks Polyproof. White In Colour Rotational Moulded Polyethylene (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position Including Supply And Fixing Of Suitable Size Inlet/Outlet Arrangement & Other Accessories Complete All As Specified And As Directed By Engineer-In-Charge. 115 Supply And Fixing In Repair Ball Valve High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Of Size 20 Mm Bore (Minimum Weight 20Mm-210 Gram) Complete All As Specified And As Directed By Engineer-In- Charge. 116 Supply & Fixing In Repair Gun Metal, Globe Or Gate Valve (Isi Marked), Brass Cast Copper Alloy, With Iron Wheel Head, Screwed Both Ends Suitable For 20Mm Bore Iron Pipes Complete All As Specified And As Directed By Engineer-In-Charge. 117 Supply & Fixing In Repair Gun Metal, Globe Or Gate Valve (Isi Marked), Brass Cast Copper Alloy, With Iron Wheel Head, Screwed Both Ends Suitable For 25Mm Bore Iron Pipes Complete All As Specified And As Directed By Engineer-In-Charge. 118 Supply And Fixing In Replacement Bevelled Edge Mirror Selected Quality 5Mm Thick Glass Mounted And Fixed To With Chromium Plated Brass Screws And Cup Washers, With And Including Pvc Frame Around Made Of Pvc Channel, Complete All As Specified And Directed By Engineer-In-Charge. 119 Supply And Fixing In Repairs Sheet Glass Shelf Assembly Consisting Of 5.5Mm Thick Sheet Glass Shelf 12Cm Wide With Chromium Plated Bracket Guard And Railing 60Cm Long Complete All As Specified And As Directed By Engineer-In- Charge. 120 Roughening Surfaces Of Old Concrete Floor By Picking, Sweeping Clean And Washing Down With Water To Remove Dust, Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 121 Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing), Removing Serviceable Tiles To Store And Rubbish Off The Permises Etc. Complete All As Specified And Directed By Engineer-In-Charge. 122 M&L For Pcc (1:2:4) Type B-1, Using 20 Mm Graded Stone Aggregate As In Floor Surface Finished Fair 30 Mm Thick Below Tiles Complete All As Specified And Directed. . 123 M & L Non-Skid Coloured Ceramic Tiles 7 To 8 Mm Thick (Square/ Rectangular) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over & Including 15Mm Thick Screed In Cm 1:6 Complete All As Specified And Directed. 124 Material And Labour 25Mm Thick Cement Concrete Type B-1, 1:2:4 (12.5 Mm Graded Stone Aggregate) As Floors, Sub-Floors Etc And Finishing Surfaces Of Concrete Topping As Even & Fair Or Even & Rough To Receive The Topping Layer Complete All As Specified And Directed By Engineer-In-Charge. 125 Material And Labour For Double Charge Vitrified Ceramic Tiles ,Stain Free, Having Size Not Less Than 600X300Mm And 8 Mm Thick, Premium (1St Quality) Straight Edge, Colour As Approved By Ge , As In Vertical Surfaces Such As Skirting , Set And Jointed In Neat Cement Slurry And Laid Over And Including 10 Mm Thick Rendering In Cement Mortar 1:4 Complete All As Specified And As Directed By Engineer-In- Charge. 126 Material And Labour Granite (Of Any Type) Work (Table Rubbed And Polished) As In Steps, Pillars,Win Dow-Cills, Cooking Platforms And Like In Laid Over And Including 15 Mm Thick Screed In Cement Mortar (1:4) And Pointing In White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Marble Shade And Roundening To The Edge Of Stone Slabs On Edges Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 127 Dismantling Stone Slabs And Tiles Of Any Description Or Thickness In Floors, Aprons Etc Laid Dry Or Bedded And Pointed In Any Mortar Complete All As Specified And As Directed By Engineer-In-Charge. 128 Demolition Of Cement Concrete Reinforced Of Any Discription And In Any Position, Including Reinforcement Cut As Required To Facilitate And Including Removing Rubbish Material From Building And Thrown In Low Lying Empty Area (As Per Direcction Of Age/Je) At Any Distance Upto 500 Metres From The Site Complete All As Specified And As Directed By Engineer-In-Charge. Note:The Weight Of Scrap Iron For Schedule Of Credit Shall Be Ascertain By Boo As Ordered By Ge.The Copy Of Boo Duly Countersinged By Ge Shall Be Enclosed With Final Bill. 129 Material And Labour For Reinforced Cement Concrete, Nominal Mix,1:2:4, Type-B1, Using 20 Mm Graded Stone Aggregate As In Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs And In Shelves And The Like Including Proper Compaction By Using Mechanical Viberator Complete All As Specified And Directed. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 130 Supply And Fixing Pvc (Hdpe) Swr, 110 Mm Bore, Single Socketed In Any Length With Rubber Ring Joints Using Solvent As Per Manufacture Instruction, Fixed To Walls Complete All As Specified Including Fixing Of Pipe To Wall With Flat Irons Clamps Of Size 25 X 3 Mm, Bolts, Washers, Nuts, Nails Etc, After Taking Down Existing Damaged Rain Water Pipe Complete All As Specified And Directed 131 Material & Labour For In Repair 75 Mm Dia Pvc (Swr) Floor Trap Type B , Plain With Grating Including Jointing With Solvent Complete All As Specified And Directed By Engineer-In-Charge. 132 Material & Labour For 100 Mm Dia Pvc (Swr) Floor Trap Type B , Plain With Grating Including Jointing With Solvent Complete All As Specified And Directed By Engineer-In-Charge. 133 Material And Labour For Water Proofing Tratment To Roof / Terrace (Material Of Water Proof Treatment As Approved By Ge) Single Component, Acrylic Based, Flexible, Micro Fibre Reinforced Waterproofing And Heat Reflective Coating System. The Treatment Shall Be Carried Out As Per The Manufacturers Instructions And Shall Include The Followings:(A) Preparation Of Substrate And Cleaning It Off All Loose And Triable By Mechanical Means(B) Open The Cracks Lines To Form , V Grooves With Cutter/Hammer/Chisel Up To 5-10Mm And Filling With Crack Filler And Pu Sealant.(C) Application Of Primer Coat @ 0.2 To 0.3 Kg/ Sqm Followed By The First Coat @ 0.75Kg/ Sqm.(D) The Second Coat Shall Be Applied @ 0.75 Kg / Sqm And Reinforced With Fabric Re-Inforcement Between The First And Second Coat.(E) The Top Coat Of Primer Shall Be Applied After The Second Coat Dries Off @ 0.05-0.08 Kg Per Sqm.(F) The Material Shall Adhere To Following Specification. Technical Specification Of Materialtensile Strength 1.5 Mpa Astm D412Elongation At Break > 200% Astm D412Adhesion In Peel > 1.5 Mpa (On Concrete Substrate) En 1542Crack Bridging Ability Passes Upto 3.2Mm Width Astm C1305Permeability To Water Vapour Passes Is 2645Water Vapour Transimission ~ 23 G/M²/24Hr Astm E96Water Absorption 134 Material And Labour For 40Mm Average Thick Pcc Padding In 1:2:4 Type B-1 (Using 20Mm Graded Stone Aggregates) As In Roof Slab Finishing The Surface Even And Fair Using Liquid Water Proofing Compound Complete All As Specified And Directed. Liquid Water Proofing Compound Shall Be Measured And Paid Separetly As Supply Only Under Appropriate Item Of Schedule A Boq. 135 Material And Labour For Making Benching With Pcc 1:2:4 Type- B0, Using 12.5Mm Graded Stone Aggregates Using With Liquid Water Proof Compound As Per ManufacturerS Instruction Along Side Wall Adjoining To Roof In Concave Shape Complete All As Specified And Directed. Note : Liquid Water Proofing Compound Shall Be Measured And Paid Separetly As Supply Only Under Appropriate Item Of Schedule A Boq. 136 Material And Labour For Cement Concrete 1:2:4 , Type B-2 Using 40 Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 137 Material And Labour For Water Proofing Compound Complete All As Specified And Directed. 138 Supply And Laying Dwcpe (Sn 8) Drain Pipes 150 Mm Nominal Dia As Per Is-16098 (Part-Ii), Laid In Trenches On Bed Including All Accessories/ Fittings/ Jointed Ring, Jointing And Testing Complete All As Specified And As Directed By Engineer-In- Charge.Note:- Excavation , Earth Work, Bedding And Pedestal / Anchorage If Required Shall Be Measured And Paid Separately Under Appropriate Item Of Boq/ Sch A 139 Material And Labour For Pcc (1:3:6) Type C-2 Using 40 Mm Graded Stone Aggregates As In Concrete Bed Of Sgsw Drain Pipes Of 150 Mm Bore, Laid To Required Slope Including Packing Under And Haunching Against The Sides Of Pipes After They Are Laid And Tested Complete All As Specified And As Directed By Engineer-In-Charge. Note :- (I) Thickness Of Concrete Bed Below The Barrel Of Pipe Shall Be 10 Cm. (Ii) Width Of Concrete Bed Shall Be Outer Diameter Of Drain Pipes (Not Of Sockets / Collar) Plus 30Cm. 140 Material & Labour For Antitermite Treatment Along The External Wall Below Concrete Or Masonry Apron Using Chemical Emulsion @ 2.25 Litres Per Linear Metre Including Drilling And Plugging Holes Etc. In Apron/Plinth Etc., Complete All As Specified And As Directed By The Engineer-In-Charge. 141 Material And Labour For Att At Points Of Contact Of Wood Work By Chemical Emulsion (In Oil Or Kerosene Based Solution) @ 0.5 Litre/Hole By Drilling 6Mm Dia Holes At A Downward Angle Of 45 Degree At 150Mm Centre To Centre And Sealing The Same Complete All Sepecified And Directed By Engineer-In-Charge. 142 Material And Labour For Att Of Soil Under Existing Floors Using Emulsion @ One Liter Per Hole, 300Mm Apart Including Drilling And Plugging 12Mm Dia Holes With Cement Mortar 1:2 (1 Cement :2 Coarse Sand) To Match The Existing Floors Complete All Sepecified And Directed By Engineer-In-Charge. 143 Material And Labour For Writing Letters Or Figures (Block,Roman, Italic Ot Indian) Of Any Description, Not Exceeding 30Cm High With Paint Complete All Sepecified And Directed By Engineer-In-Charge. 144 Material And Labour For Cutting Into Existing Manholes For Connecting New Drains, Making Good To Pipe And Rendering, Cutting Out Existing Benching For And Forming Branch Channel (1/2 Round Or 3/4 Section) In Cement Concrete 1:2:4 Type B-L Smooth Finished, And Reforming Benching As Required For Internal Dia Of Pipe In 150 Mm Complete All As Specified And As Directed By Engineer-In-Charge. 145 Taking Down Cement Or Cement Lime Plaster On Brick Or Stone Walls, Etc. Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water, Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 146 Material And Labour For 15Mm Thick Rendering In Cm (1:6) (Internal Surface) On Other Than Fair Faces Of Brick Work Or Concrete Surfaces And Finishing Even & Smooth But Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 147 Material And Labour For Factory Made,Machine Pressed Precast Interlocking Paver Block 60 Mm Thick With Grey Cement And No Pigment, Any Shape And Size, Conforming To Is 15658-2006, Made Out Of M-35 Grade Concrete Laid Over Sand Cushioning Complete All As Specified And As Directed By Engineer-In- Charge. Note: The R Sand Cushioning Shall Be Measured And Paid Seperately Under Appropriate Item Of Schedule A Boq. 148 Dismantling Of Brick Tiles Or Terracing Tiles Single Layer On Roof & Disposal Of Retrieved Material Upto A Distance N.Exc 100M Where Directed, Complete All As Specified And Directed By Engineer-In- Charge. 149 Demolition Of Mud In Roofs, Any Thickness, Including Plastering And Leeping (Whether Full Thickness Removed Or Only A Part Thereof Disposal Off Rubbish Upto A Distance Not Exceedomg 500.00Mtr Where Directed ) Complete All As Specified And Directed By Engineer-In- Charge. 150 Material And Labour For 15Mm Thick Screed Bed Or Bedding Layear In Cement Mortar 1:4 On Roof Surfaces, Parapet Or Vertical Beam Surface (Horizontal Or Vertical) Finishing The Surfaces Even And Fair Complete All As Specified And Directed By Engineer-In-Charge. 151 Supply And Fixing Anodised Aluminium Handle, Fabricated Type 150Mm Long Complete All As Specified & Directed By Engineer-In-Charge. 152 Supply And Fixing Aluminium Anodised Barrel Tower Bolt Of Extruded Section, 200Mm Long Complete All As Specified & Directed By Engineer-In-Charge. 153 Supply & Fixing Aluminium Anodised Sliding Door Bolts 300Mm Long, With Hasp And Staple (Bolt Type) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast-Aluminium Alloy And Fixed Complete All As Specified & Directed By Engineer-In- Charge. 154 Supply & Fixing Factory Made Steel Window Confirming To Is 1038 With Side Hung Shutters Including Projecting Type Hinges, With Steel Handle, Steel Peg Stay, Complete, Dovetailed Welded, With And Including One Shop Coat Of Zinc Chromate Primer Without Glazing Bars Including Making Good As Per Existing Surfaces Complete All As Specified & As Directed By Engineer-In- Charge.Note: The Rate Of One Shop Coat Of Zinc Chromate Primer Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 155 Supply & Fixing Factory Made Steel Window Confirming To Is 1038 With Side Hung Shutters Including Projecting Type Hinges, With Steel Handle, Steel Peg Stay, Complete, Dovetailed Welded, With And Including One Shop Coat Of Zinc Chromate Primer With Glazing Bars Including Making Good As Per Existing Surfaces Complete All As Specified & As Directed By Engineer-In- Charge.Note: The Rate Of One Shop Coat Of Zinc Chromate Primer Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 156 Supply Only 3.00 Mm Thick Sheet Glass Ordinary Quality ,Fixing With Oil Putty To Wooden Or Steel Surface N.Exc 0.5 Sqm Each Complete All As Specified And Directed 157 Material & Labour For Excavating In Post Holes (Or Similar Holes) Each N Exc 0.5 Cu. M, Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25 Cm, In Soft / Loose Soil Complete All As Specified And Directed By Engineer-In- Charge. Complete All As Specified And Directed By Engr-In-Charge. 158 Supply And Fixing For Mild Steel Screw Bolts 5Mm To 10Mm Dia Of Neck (Machine Made) With Hexagonal Or Square Heads At One End And Screwed The Other, Or Screwed Both Ends, Each Screwed End To Be Fitted With Washers And One Hexagonal Or Square Nut, Length Of Bolt Exc 5Cm But N Exc 10Cm Long Complete All As Specified And Directed By Engr-In-Charge. 159 Supply And Fixing For Pre -Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thickness Of Any Colour Having Atensile Strength Of 550 Mpa As In Roof Covering Fixed With L Type Or J Type Or Cranked Hook Bolts All As Specified And Directed By Engineer-In-Charge. 160 Material And Labour For Roof Trusses (Framed), Trussed, Purlins, Crane Gantries, Rails And Fastenings And Heavy Bracket Framing (Beam, Tee, Angle, Channel Or Flat Sections) Including Distance Pieces, Cleats Etc Complete All As Specified And Directed By Engr-In-Charge. 161 Material And Labour For Steel Work In Tubular Post 100Mm Dia Including Special Shaped Washer Etc. Complete Using Erw Or Induction Butt Welded Tubes Conforming To I. S.1161- 1979 Grade St.-240 Including Rolled Mild Steel Joist, Channel, Angle, Or Tee Sections, Fixed Independently, Without Connecting Plates, Etc. (Cut To Ordinary Lengths I.E. Within 20Mm Of The Length Indicated Of Gde Fe 410 -S, Complete All As Specified And Directed By Engr-In-Charge. 162 Supply And Fixing In Repairs Magic Eye For Flush/Panelled Door Shutter Etc Complete All As Specified And As Directed By Engineer-In-Charge. 163 Supply And Fixing Framed Work As In Doors Or Gates Of Angle Or Other Section With Gusset Plates, Rails, Braces, Etc., Complete, Drilled For Fixing Of Steel Sheeting Or Other Covering. Doors, Etc. To Be Prepared For Hanging Or Sliding With And Including Either Hooks And Hinges Or Steel Hanging Door Fittings (Exclusive Of Steel Sheeting Or Other Covering, Running Rails And Guides) Andhanging; Also Fastening And Fixing Complete Complete All As Specified And Directed By Engineer-In -Charge. 164 Material And Labour For Preparation Of New Steel Surfaces Of Any Description Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over With And Including One Coat Of Red Oxide Zinc Chrome Primer Complete All As Specified And As Directed By Engineer-In-Charge. 165 Material And Labour For Preparing Old Steel Surfaces Of Any Description Over 10 Cm Width Or Girth And Applying One Coat Of Synthetic Enamel Paint Complete All As Specified And As Directed By Engineer-In- Charge. 166 Dismantling Boarding, Any Description, Fixed In Any Position With Nails Complete All As Specified And As Directed By Engineer-In- Charge. 167 Supply & Fixing 18Mm Thick Hdhmr Board Uv Coating, Exterior Grade As Approved By Ge, With And Including Acrylic High Gloss Sheet Of Min 1Mm Thick Over Hdhmr Board, Anti Fungal, Moisture Resistance, Anti Borer, As Per Is 14587 For Frame And Shutter For Kitchen Cabinets / Cupboards (Such As Side Wall, Shutter, Partition Back Side Of Etc. Of Cupboard And Cabinets). Complete All As Specified And Directed By Engg-In-Charge. 168 Supply & Fixing In Repairs Of Stainless Steel Cabinet / Drawers Handle Having A Length Of 250Mm And Shape Complete All As Specified And Directed. 169 Supply & Fixing In Repairs Of Partial Overlay / Fully Overlay Hydraulic Self Closing Concealed Hinges Having Size 103Mm X 64Mm Finish Of Nickel/Silver As Approved By Ge Complete All As Specified And Directed By Engg-In-Charge. 170 M&L For 40Mm Gi Pipe Medium Grade Made To Shape As In Spout Pipe As In Sunken /Verandah/ Balconey Complete All As Specified And As Directed. 171 Supply And Laying Or Fixing Or Laid In Trenches/ Ducts/ Through Pipes/ In Floors / Under Roads/ Hard Standing /Along Poles And Testing Lt Cable Xlpe, Pvc Insulated Screened, Bedded, Galvanised Steel Strip Or Wire Armourd Cable (Heavy Duty) 1100 Volt Grade With Aluminium Conductor Having Cross Sectional Area 70 Sqmm X 3.50 Core Conforming To Is-7098 (Part-I -1988) Complete All As Specified And As Directed By Engineer-In-Charge. (Excavation And Earth Work, Sand Cushioning & Gi Pipe Shall Be Measured And Paid For Separately) 172 Taking Down Carefully Copper /Aluminium Point Wiring (Light, Fan, Socket Or Power Point ) Complete Including Fitting Such As Hylem , Sheet Switches, Ceiling Rose, Pendent Holder , Sockets, Fan Regulator , Bell Push, Electronic Bell , Sunken Box Except Concealed Conduit Etc. Complete All As Specified And Directed By Engineer-In-Charge. Notes:(I) The Weight Of Aluminium Scrap , Copper Scrap And Iron Scrap Shall Be Ascertained By Boo As Ordered By Ge And Same Duly Countersinged By Ge Shall Be Enclosed With Final Bill. (Ii) The Rate Of Cutting Chases (As Required) And Making Good Surfaces To Match With Adjoining Surface Shall Be Measured And Paid Seperately Under Serial Item No. 173.00, 174.00, 175.00, 176.00, 177.00, 178.00, 179.00, 180.00, 181.00, 182.00, 183.00, & 184.00 Of Boq. 173 Material And Labour Point Wiring For One Light / Fan Point Controlled By 6 Amps One Way Modular Switch Switch With 2.5 Sqmm Pvc Insulated, Unsheathed Multi Strand Copper Conductor Cable Fr-Lsh In And Including Concealed Pvc Conduit 20 Mm Dia Heavy Duty Isi Marked, Steel Terminal Sunken Boxes And 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point, Controlled By One Switch On The Same Board With Other Switch Or Independent Including Cutting, Chasing The Surface And Then Making Good The Same In Cm (1:3) Complete All As Specified And Directed By Engineer-In-Charge. (Note:- Switches, Sockets Etc Shall Be Measured And Paid For Separately Under Items Of Schedule). 174 Material And Labour Point Wiring For One Light / Fan Point Controlled By 6 Amps Two Way Modular Switch Switch With 2.5 Sqmm Pvc Insulated, Unsheathed Multi Strand Copper Conductor Cable Fr-Lsh In And Including Concealed Pvc Conduit 20 Mm Dia Heavy Duty Isi Marked, Steel Terminal Sunken Boxes And 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point, Controlled By One Switch On The Same Board With Other Switch Or Independent Including Cutting, Chasing The Surface And Then Making Good The Same In Cm (1:3) Complete All As Specified And Directed By Engineer-In-Charge. (Note:- Switches, Sockets Etc Shall Be Measured And Paid For Separately Under Items Of Schedule). 175 All As Per Item No 174.00 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 6 Amp, On Same Board Complete All As Specified And As Directed By Engineer-In- Charge. 176 All As Per Item No 17400 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 6 Amp, On Independent Board Complete All As Specified And As Directed By Engineer-In- Charge. 177 All As Per Item No 174.00 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 5/15 Amp, On Independent Board Complete All As Specified And As Directed By Engineer-In- Charge. 178 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For Modular Bell/Buzzer Point Controlled By One Push Button On Independent Board But Not Below The Switch Board, Complete All As Specified And Directed By Engineer-In-Charge. 179 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For Modular Socket Outlet 3 Pin 6 Amp On Independent Board Complete All As Specified And Directed By Engineer-In-Charge. 180 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For 15/16 Amp Socket Out Let By Using 2.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Cable Fr-Lsh Multi Strand On Independent Board Including Provn 2.5 Sqmm Unsheathed, Multi Stranded Copper Conductor Cable Fr-Lsh Continues As Earth Wire Connected To Earth Dolly Etc Complete In Existing Conduit Complete All As Specified And As Directed By Engineer-In-Charge. 181 Material And Labour For Point Wiring For One Light / Fan Point Controlled By One Switch With 1.5 Sqmm (Nominal Area) Pvc Insulated Unshealthed Multi Stranded Copper Conductor Cable Fr-Lsh In Existing Conduit And Provision Sunken Boxes But Inclyding 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point Controlled By One Switch And Fan Regulator Including Pvc Insulated Unshealthed 1.5 Sqmm Copper Conductor Cable Fr-Lsh Connected To Common Earth Dolly Complete All As Specified And Directed 182 All As Per Srl Item No 181.00 (Here-In-Before) But Socket 3 Pin 5 Amp 230 Volt Flush Type On Same Board 183 All As Per Srl Item No 181.00 (Here-In-Before) But For One Socket Point Outlet 3 Pin 5 Amp In Incdependent Board 184 All As Per Serial Item No 181.00 Of Boq Here-In-Before But For 15 Amp Socket Out Let By Using 1.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Cable Fr-Lsh Multi Strand On Independent Board Including Provn 2.5 Sqmm Unsheathed, Multi Stranded Copper Conductor Cable Fr-Lsh Continues As Earth Wire Connected To Earth Dolly Etc Complete In Existing Conduit Complete All As Specified And As Directed By Engineer-In-Charge. 185 Supply And Fixing Switch Piano, Flush Type Single Pole, One Way 5 Amp Complete All As Specified 186 Supply And Fixing Switch Piano, Flush Type Single Pole, One Way 15 Amp Complete All As Specified 187 Supply And Fixing Socket Outlet 3 Pin, 5 Amp Flush Type All As Specified 188 Supply And Fixing 2 In 1, 3 Pin, 5 And 15 Amp Flush Type Complete All As Specified 189 Supply And Fixing Modular Switch One Way , 6Amp/10Amp ,1 Module, Single Pole, 250 Volts ,Ac Supply, Isi Marked , Complete All As Specified And Directed By Engineer-In-Charge 190 Supply And Fixing Modular Socket Outlet , 6 Amp-2/3 Pin Combined 2 Module , 230 Volts , Multipurpose, Ac Supply, Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 191 Supply And Fixing Modular Switch One Way 16 Amp, Single Pole, 1 Module 230 Volts , Ac Supply , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 192 Supply And Fixing Modular Switch Two Way 6 Amp, Single Pole, 1 Module 230 Volts , Ac Supply , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 193 Supply And Fixing Modular Bell Push Switch 6A 1 Module , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge.Note: (I) Labour Element For Taking Down Old Unservicable Material Is Included In Serial Item No.172.00 Of Boq Here-In -Before And Nothing Shall Be Extra Paid On This Account. 194 Supply And Fixing Modular Socket Outlet 6Amp/16Amp-2/3 Pin Combined,2 Module ,230 Volts ,Multi Purpose, Ac Supply, Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 195 Supply And Fixing Fan Regulator, Modular Type, 5 Step, High Speed, Two Module Complete All As Specified And Directed By Engineer-In-Charge. 196 Supply And Fixing Ceiling Rose 3 Terminal Flush Type 6 Amp 250V ,Isi Marked ,Ac Supply, Topline Series With Polycarbonate 20Mm X 50 Mm Two To Three Terminal, Complete All As Specified And Directed By Engineer-In-Charge. 197 Supply And Fixing Electric / Electronic Bell, Ding Dong Type 230 Volt Ac Supply,Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 198 Supply And Fixing Wall Mounted Extruded Aluminium/Polycarbonate Led Batten Fixture T8(G13 Holder) 1.2 M Including One Led Retrofit Tube 20(±10) Watt. 1.2 M T8 6500 Efficacy Not Less Than 90 Lumen/Watt Extruded Aluminium/Polycarbonate, Pc Diffusor And Inbuilt Driver Complete Including Making Connection Complete All As Specified And Directed 199 Supply And Fixing Lamp Holder ,Isi Marked Of Pvc/Polycarbonate Type With Back Plate Suitable For Batten Fitting With And Including 9Watt Led Retrofit Lamp (Base B-22) Complete All As Specified And Directed By Engineer-In-Charge. 200 Supply And Fixing Lamp Holder Pvc/ Polycarbonate Type With Back Plate Suitable For Batten Fitting With Led Bulb 5 Watt Lamp Base- B-22 Complete All As Specified And As Directed By Engineer-In- Charge.Note: Labour Element For Taking Down Old Unservicable Material Is Included In Serial Item No.172.00 Of Boq Here-In -Before And Nothing Shall Be Extra Paid On This Account. 201 Supply Only Led Bulb 9 W (Suitable For B22 Base), 250V Ac, Green/Red/ Clear Day Light ( Cdl) In Colour Complete All As Specified And Directed By Engineer-In-Charge.As Per Direction Of Engineer-In-Charge Colour Of Led Luminiure Cdl/Warm White Shall Be Provided By The Contractor As Per Site Requirment And Nothing Shall Be Paid Extra On This Account.Notes:(A) Contractor Has To Furnish A Replacement Warranty Of 02 Years For Led Bulb Complete Including Lamp/ Strip From The Certifiy Date Of Completion Of Ca. The Product Will Be Replaced Free Of Cost In The Following Case :-(I) Manufacturing Defects.(Ii) Failure Due To Mechanical And Electrical Impact. (Iii) Drop In Lumen (Or Lux At 1 M) Below 90% Of Clamied Values Of Lumen(Or Lux At 1 M) Of The Led Bulb . (B) All Led Bulbs Must Meet The Provision Laid Down In Is - 16101, 16102 Part -I/Ii,16103 Part -I, 16104,16105,16106, 16108/2012 And 15885 Part -Ii / Section 13. (C) Scope Of Work Shall Include To Fix Led Bulb Walls/Ceiling Which Includes Needful T & P And Required Accessories Etc If Any, Complete Including Making Connection, Testing Etc Complete. No Extra Payment Is Admissible On These Account.(D) Old Unservicable Retrieved Material Shall Be Deposited In The Store Yard Of Age E/M Ge (North) Bathinda By The Contractor His Own Arrangements And Nothing Shall Be Paid Extra On This Account. (E) The Rate Of Electric Connection Connecting With Using Flexible Copper Wire Twin Core Upto Ceiling Rose/Connector Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 202 Supply And Fixing In Replacement Led Panel Light Fitting Recessed Mounted,Square Shaped Of Size 600Mm X 600Mm , 36 (±10%) Watt, Efficacy Not Less Than 100 Lumen/Watt , Extruded Aluminium/Polycarbonate, Pc Diffusor And Inbuilt Driver Complete As Per ManufacturerS Instructions With And Including Connection With Flexible Twin Core Copper Cable Of Size 23/.00076 From Ceiling Rose To Fitting Complete All As Specified And As Directed By Engineer-In- Charge. 203 Material And Labour In Replacement Sub Main Wiring Complete With Two Single Core 6 Sqmm,1100 Volts Grade, Pvc Insulated, Multi Stranded Copper Conductor Cable Frlsh With And Including Single Core 6 Sqmm,1100 Volts Grade, Pvc Insulated, Multi Stranded Copper Conductor Cable Frlsh For Earth Wire In Existing Pvc Concealed Conduit (Colour Code Phase-Red, Neutral-Black And Earth As Green) Complete All As Specified And Directed By Engineer-In-Charge. Notes:-(A) Three Single Core 6 Sqmm Frlsh Pvc Insulated Unsheathed With Multistranded Copper Conductor Cable 1100 Volts Grade Shall Be Measured As One Length. 204 Supply And Fixing In Replacement Mcb 40Amp -63 Amp Spn ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 205 Supply And Fixing In Replacement Mcb 6Amp -32 Amp Sp ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 206 Supply And Fixing In Replacement Mcb 32 Amp Spn ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 207 Supply And Fixing In Replacement Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Double Door, Powder Coated Db Spn 8 Way 240 Volt, Ip -54, 200 Amps Rated Bus Bar, Dust And Vermin Proof Suitable For Incorporation Of McbS And Isolators Etc Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 208 Supply And Fixing Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Double Door, Powder Coated Db Spn 12 Way 240 Volt, 200 Amps Rated Copper Bus Bar, Dust And Vermin Proof Suitable For Incorporation Of McbS And Isolators Etc Complete Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 209 Supply And Fixing In Replacement Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Ip-54 Protection, Flush Mounted For Metal Door, Powder Coated Db Tpn 4 Way, 415 V Ac With 63 Amps Rated Bus Bar, Double Door, Dust And Vermin Proof Suitable For Incorporation Of Incoming Mccb And Outgoing Mcb Sp/Tp And Earth & Neutral Bus Bar Etc Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 210 Supply And Fixing Wall Mounted Extrdued Aluminium Housing Led Betten Fixture With Tube 1.2 M, 20 Watt Inverter Type, 1.2 M 3000/6500K, Efficacy Not Less Than 90 Lumen/Watt, Extruded Aluminium/Polycarbonate, Pc Diffusor And Integrated Inbuilt Driver Complete Including Making Connection Complete All As Specified And As Directed By Engineer-In- Charge. 211 Supply And Fixing Wall Mounted Extrdued Aluminium Housing Led Betten Fixture With Tube 1.2 M, 25 Watt Inverter Type, 1.2 M 3000/6500K, Efficacy Not Less Than 90 Lumen/Watt, Extruded Aluminium/Polycarbonate, Pc Diffusor And Integrated Inbuilt Driver Complete Including Making Connection Complete All As Specified And As Directed By Engineer-In- Charge. 212 Supply And Fixing Led Batten Fitting 1X10 Watt, 6500K, 2 Ft Complete With Decorative Ultra Slim Square Profile Led Lighting Fixture With Extruded Polycarbonate Environment Friendly, Energy Efficient Complete With All Light Connection All As Specified And Directed 213 Supply And Fixing In Repair Led Street Light Fitting 35 Watt 230 V Ac Outdoor Type With High Pressure Die Cast Aluminium Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Complete With Ip 65/66 Protection Including Fixing With Gi/Ms Bracket Made Out Of Suitable Size Of Light Grade Tube Upto 1.2 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Iron With Suitable Bolt And Nuts Complete With Making Connection Complete All As Specified And Directed 214 Supply & Fixing Building Security Led Light Of 35 Watt , Ip 66 , Luminaire With High Power With Toughened Glass Complete As Per ManufacturerS Instructions With And Including Bracket Made Out With 40Mm Bore Galvanised Iron Light Grade Pipe 1.20 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Suitable Bolt ,Nuts And Washers Complete And Fixing To Wall / Column With And Including Electrical Connection With 1.5 Mtr Long Twin Core Round Copper Conductor Cable Of Suitable Size And Testing Complete All As Specified And Directed By Engineer-In-Charge. Notes:(A) The Rate Of Bracket Made Out With 40Mm Bore Galvanised Iron Light Grade Pipe 1.20 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Suitable Bolt And Nuts And Electrical Connection With 1.5 Mtr Long Twin Core Round Copper Conductor Cable Of Suitable Size Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (B) Contractor Has To Furnish A Replacement Warranty Of 02 Years For Security Led Light Fittings Complete Including Lamps From The Certifiy Date Of Completion Of Ca. The Product Will Be Replaced Free Of Cost In The Following Case :-(I) Manufacturing Defects.(Ii) Failure Due To Mechanical And Electrical Impact. (Iii) Drop In Lumen (Or Lux At 1 M) Below 90% Of Clamied Values Of Lumen(Or Lux At 1 M) Of The Led /Luminaries. (C) All Security Led Light Must Meet The Provision Laid Down In Is - 16101, 16102 Part -I/Ii,16103 Part -I, 16104,16105,16106, 16108/2012 And 15885 Part -Ii / Section 13. (D) Scope Of Work Shall Include To Fix Security Led Light Fittings Walls/Building Which Includes Needful T & P And Required Accessories Etc If Any, Complete Including Making Connection, Testing Etc Complete. No Extra Payment Is Admissible On These Account. 215 Supply And Fixing Jointing Of Double Walled Corrugated Pipe (Dwc) As Ug Cable Protection Complete Of Size 63 Mm, Complete All As Specified And Directed By Engineer-In-Charge 216 Supply And Fixing Jointing Of Snap Fit Coupler For Double Walled Corrugated Pipe (Dwc) Of Ug Cable Protection Complete Of Size 63 Mm, Complete All As Specified And Directed By Engineer-In-Charge 217 Supply And Fixing Mccb With Adjustable Type, 4 Pole, 63 Amps, 415 Volts, 50 Hz, 25 Ka And Including Sheet Metal Enclosure Out Door Type Made Out Of 3.15 Mm Thick Crca Sheet Mounted On Angle Iron Padesta Including Grouting Complete All As Specified And Directed By Engineer-In-Charge. 218 Material And Labour For Earthing Complete With Galvanised Steel Earth Plate Electrode 600Mm X 600Mm X 6 Mm Thick Burried Directly In Ground To Depth Of Pit Not Less Than 2.25 M Below Normal Ground Level With Top Edge Of The Plate Not Less Than 1.5 M Below Normal Ground Level Surrounded From All Sides By 15 Cm Thick Packed Layer Of Charcoal / Coal Dust And Common Salt Filling In Alternate Layers And Connected To Galvanised Earth Lead Wire 4 Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Of Gi Or Steel Including Gi Protection Pipe 15Mm Dia Light Grade Upto The Extent Of 7.5 Metre And Connecting To Earthing Test Point, Main Switch Board Including Gi Pipe 20 Mm Dia Light Grade For Watering, Ms Funnel And Bringing Out The Watering Pipe Upto 30 Cm Above The Normal Ground Level Plugged At Top Including All Fitting Including Pcc Earth Pit With Pcc 1:2:4 Type B-1 Using 20Mm Graded Stone Aggregate And Rcc Pit Cover Including Necessary Earthwork And Excavation In Any Type Of Soil Complete All As Specified As Shown In Electrical Plate No 3 Of Ssr Part-I And Testing On Completion. Note:- (I) Earth Continuity Of Gi Wire 4 Mm Including Protection Pipe Up To 7.5 Mtrs From Earth Electrode Will Be Included In Unit Rate, Complete All As Specified And Directed. (Ii) The Rate Of Earth Work In Soft/Loose Soil I.E. Excavation, Returing Filling And Removal, Form Work Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) Pcc Chamber Shall Be Constructed At Least 1.5 Metre Away From The Earth Electrode And Pipe For Watering Shall Be Provided In Slanting Manner. (Iv) The Earth Testing Arrangement Should Be Done By The Contractor As Per Direction Of Engineer-In-Charge. 219 Supply And Fixing 1100 Volts Grade Heavy Duty Cable Pvc Insulated Aluminium Strandred Conductor 6Sqmm, Served With Inner Sheathing Of Pvc Tape And Overall Pvc Sheathed In Service Connections Suspended By Insulating Hangers Not More Than 1 Mtr Apart Including 4Mm Suspenstion Wire, One Twin Core Cable Flat All As Specified And Directed 220 Supply And Fixing In Replacement Exhaust Fan 300Mm Sweep (Heavy Duty) Steel Body, Bee, 5 Star Rated ,Ac Supply, Single Phase ,230 Volts, 50Hz,1200Rpm With And Including Frame Including New Mosquito Stainless Steel Wire Mesh Of Guage 0.36Mm With Suitable Wooden Frame Protection Against Birds Etc. Mounted In Suitable Opening Arrangmement In Wall And Electric Connection With And Including Three Core Pvc Insulated Pvc Sheathed Copper Conductor Flexible Cable 24/0.2Mm Drawn In Flexible Pvc Conduit And Hanging On Wall With 04 Nos. Steel Fastners 10Mm Dia 100Mm Long With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 221 Supply And Fixing Exhaust Fan 250Mm Sweep (Heavy Duty) Steel Body, Bee, 5 Star Rated ,Ac Supply, Single Phase ,230 Volts, 50Hz,1200Rpm With And Including Frame Including New Mosquito Stainless Steel Wire Mesh Of Guage 0.36Mm With Suitable Wooden Frame Protection Against Birds Etc. Mounted In Suitable Opening Arrangmement In Wall And Electric Connection With And Including Three Core Pvc Insulated Pvc Sheathed Copper Conductor Flexible Cable 24/0.2Mm Drawn In Flexible Pvc Conduit And Hanging On Wall With 04 Nos. Steel Fastners 10Mm Dia 100Mm Long With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 222 Taking Down Unserviceable Complete Ceiling Fan Along With Blades And Deposited To Age E/M Store Yard Of Ge (South Bathinda) Complete All As Specified And Directed By Engr-In- Charge. 223 Supply & Fixing Ceiling Fan Of 1200Mm Sweep Complete With Blades, Down Rods, With And Including Remote Control, Single Phase, 50 Hz, Min Air Delivery 210 Cfm With Service Value 6.00 Bee. Five Star Rated With Brushless Direct Current (Bldc) Motor Connecting Up Complete With And Including Three Core Flexible Pvc Insulated Multi Stranded Copper Conductor Cable Of Suitable Size From Ceiling Rose / Connector, Including Extra Gi / Ms Pipe Down Rod, As Per Site Requirement , With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 224 Dismantling And Taking Down Of Existing Energy Meter And Refixing The Same Complete All As Specified And Directed By Engineer-In- Charge, 225 Dismantling And Taking Down Existing Geyser And Deposit In The Safe Custody / Store Yard Of Age E/M Of Ge (S) Bathinda And Refixing The Same After Carring Out Repair Work/ Rewiring Accn )Complete All As Specified And Directed By Engineer-In- Charge,
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
Contract Date: Ref. Documents Contract Value : 81,713
Local Bodies No of Bidders 1
Contract Date: Ref. Documents Contract Value : 28,400
Government Departments No of Bidders 5
Andhra Pradesh View Result →
17.
Defence #10826076 Price Bid
Supply Of Op Works Store:-1 Ms Binding Wire ( Annealed ) 2 Water Proofing Silica Panels 300X300 7 - 8Mm Thick 3 Non Skid Water Proofing Silica Panels 4 Water Proofing Silica Panels 5 3 Layer Pp-R Polypropylene Random Copolymer ) 6 20Mm Elbow Suitable 7 20Mm Socket Suitable For 20 Mm 8 20Mm Equal Tee Suitable For 20 Mm Pp-R Pipes Conforming To Is 1239-1989 9 20Mm Union Suitable For 20 Mm 10 Pp-R End Plug 20 Mm 11 Pp-R Pipe Clamps Suitable For 20 Mm Pp-R Pipes 12 Brass Stop Cock 20Mm 13 Brass Bib Cock 20Mm 14 Pp-R Tank Connector 20 Mm With Check And Washer 15 Rotational Moulded Polyethylene Water Storage Tank Double Layer Type ( Cylindrical Vertical Tank ) 1000 Ltrs Capacity 16 Towel Rail Cp 750Mm Long With Fixing Clips Complete Confirming To Relevant Is 17 White Lead ( Safeda ) 18 Thread Cotton Ball 100M Long 19 110X110 Mm Nahani Trap With Jali 20 Snow White Colour European Wc With S Or P Trap Concealed 21 Snow White Colour Wash Hand Basin 22 600Mm X 450Mm Looking Mirror Cabinet With Pvc Moulded Frame 23 Pionjar Rock Drill Machine Modal Yn 27 Of Engine Rpm 2450 / M 24 Over Head Shower Without Arm Conforming To Is 8931-1978, Make : Prayag Cat No. Bos-11 25 Soap Dish For One Soap 26 Towel Ring 27 Toilet Paper Holder 28 Health Faucet With 1.5 Mtr Tube And Hook 29 Cp Pillar Cock 20Mm 30 Pre Fabricated Man Hole Cover 31 110Mm Dia Upvc Pipe 3 Mtr Long Single Socketed With Cowl 32 110Mm Dia Upvc Single Tee 33 4” Dia Upvc Bend 34 110Mm Dia Upvc Swr Pipe Single Socketed Pipe ( Type A ) In Any Length With Rubber Joint 35 Waste Bin 36 Plastic Chair With Handrest, Model Dynasty 37 Cup Board Model Freedom Fmdr 38 Looking Mirror 39 Bolt Cutter 40 Hacksaw Blade Double End 41 Combination Cutting Pliers Insulated With Thick C.A Sleeve Length 210Mm-8 Confirming To Is 3650-1990 42 Hacksaw Frame 43 Spirit Level 2 Long 44 Hand Saw Handle 45 Machine For Joining Pvc Pipe 46 Concrete Mixer Tilting Drum Type Of Cap 10 / 7 Cuft Mounted On 4 Pneumatic Type Driven By 6Hp Air Cooled Diesel Engine. 47 Heavy Duty Petrol Chain Saw 48 Portable Welding Machine Including 10 Pkt Welding Rod With Each Set 49 Cement Sprayer Gun 50 Concrete Mixer ( Portable 51 Power Earth Auger 52 Demolition Hammer 53 Power Tile Cutter 54 Snow Shovel 55 Mini Sheet Metal Cutter 56 Manual Operated Hog Plier Mode Ac 50 Mh
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
Jammu And Kashmir View Result →
18.
Defence #10801071 Price Bid
Tender For Comprehensive B R And Em Repair Maintenance Works To 14 Asc Af Kakkanad Under Age I R D Kochi; 1 Hacking out old broken glass panes 4 mm thick from steel frame including putty/ metal beadings and supply and fix sheet glass ordinary 4 mm thick, in squares n.exc. 0.50 Sqm in each pane including necessary new oil putty or with existing metal beadings complete all as specified and as directed 2 Hacking out old broken glass panes 4 mm thick from wooden framed shutters including putty/wooden beadings and supply and fix sheet glass ordinary quality, 4 mm thick, in square n.exc. 0.5 Sqm in each pane including necessary oil putty/wooden beads complete all as specified and as directed. 3 S&F in repairs extruded aluminium anodised 150 mm long handles fabricated type. 4 All as per item No 3 above but 100 mm long. 5 Supply and fix in repairs foot operated door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring and cover plate overall length 150 mm including taking down defective foot operated door stopper all as specified and as directed. 6 S&F in repairsmortice lock brass 4 levers vertical type 100 mm 7 S & Fin repairs door closer hydraulically regulated, castiron body, designation No -3, universal type ,suitable for door shuttersof 851 to1000 mm in width and of wt between 61 to 80 Kg and fixed 8 Re securing and easing to wooden shutters of any description area n.exc 1 Sqm each without taking down the shutter all as specified and as directed. 9 Re securing and easing to wooden shutters of any description exc 1 Sqmbut n.exc 2 Sqm each without taking down the shutters all as specified and as directed. 10 S&F In repairs Aluminium anodised, barrel tower bolts of extruded section 150 mm long. 11 All as per item No 10 above but 100 mm long. 12 S&F in repairs Aluminium alloy, anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections or cast-aluminium alloy, 300 mm long 13 Taking down shutters exc 1 sq. m and n exc2 sq. m each and re-fixing in same openings. 14 Taking down shutters n exc 1 sq. m each and re-fixing in same openings. 15 S&F in repairs Butt hinges, medium weight cold rolled mild steel 100 mm size. 16 All as per item No 15 above but 75 mm size. 17 Taking down and removing to or from store chowkats or framesexc 1.5 sq. m and not exc 4 sqm each but with shutters (without taking off shutters from the frames) 18 S&F Solid PVC door frame of size 50mm x 47mm made of of 5mm plain color PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing. 19 S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top and bottom rails. M.S. frame shall be covered with heat moulded plain color PVC C channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain color PVC sheets for top rail, lock rail &bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain color PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing. 20 S&F Aluminium, anodised, barrel tower boltsof extruded section and fixed length of bolt in 200 mm complete all as specified and directed. 21 S&F Butt hinges, medium weight, cold rolled mild steel, and fixed size of hinges in 100 mm complete all as specified and directed. 22 S&F Aluminium handles, cast type, anodised size of handle in 150mm 23 Supply and fix in repair PVC low level flushing cistern 10 liters capacity with ISI mark including inlet, ball valve, float, handle and brackets etc. including taking down old defective low level flushing cistern all as specified and as directed. 24 Supply and fix plastic seat and cover superior quality closed pattern with flat bottom of heavy duty including necessary hinged devices, including taking down damaged/ broken plastic seat and cover from EWC all as specified and as directed. 25 Supply and Fix in repair PVC connection with PTMT nuts of length 450 mm screwed for iron pipe15 mm bore. 26 Supply and fix in repair 15 mm dia CP pillar cocks fancy type for wash hand basin including taking down existing pillar cock, all as specified and as directed. 27 Supply and fix 150 mm square grating of PTMT to floor trap/nahani trap including taking down existing damaged CI grating from floor tap/nahani trap all as specified and as directed. 28 Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store 15mm bore pipe, all as specified and as directed. 29 All as per item No 28 above but 20mm bore. 30 All as per item No 28 above but 25/32 mm bore. 31 Supply and fix Unplasticised PVC pipes of bore 15mm, pressure rating 10 Kg/Sq. Cm pressure rating 10 Kgf/Sq. Cm all as specified and as directed 32 Supply and fix Unplasticised PVC pipes of bore 20mm, pressure rating 10 Kg/Sq. Cm pressure rating 10 Kgf/Sq. Cm all as specified and as directed 33 Supplying and laying of CPVC pipes 20 mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. 34 S&F in repairs bib taps 15mm bore, cast copper alloy chromium plated with crutch or butterfly handle, fancy type, screwed for iron pipe or for brass ferrule all as specified and as directed 35 S&F in repairs stop valves 15mm bore, cast copper alloy chromium plated fancy type, screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions all as specified and directed. 36 S&F in repairs vitreous china wash basin white flat back, size 580x450mm excluding taps waste, chain and plug and porcelain stopper including brackets all as specified and as directed. 37 S&F in repairs vitreous china wash down water closet pan (pedestal pattern) white (excluding fixing bolts flushing cistern and flush pipe). 38 Supply and fix tubular towel rail aluminium anodised20 mm dia D type 60 cm long between flanges including taking down defective aluminium tubular towel rail all as specified and as directed. 39 Supply and fix in repair beveled edgedmirror of size 600 x 450 mm selected quality glass mounted on 6mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified and directed. 40 S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls 75 mm bore. 41 All as per item 40 above but 110 mm bore 42 S&F PVC (SWR) bends any radius 75 mm bore 43 Supply and fix in repairs 100 mm dia CIfloor trap/nahani trap including taking down existing damaged CI grating from floor trap/nahani trap 44 M&L Dismantling water tanks and removing to store exc 250 & n exc 500 capacity 45 M&L Dismantling water tanks and removing to store exc 500 & n exc 1000 capacity 46 M&L Rotational moulded polyethylene water storage tanks 500 litres capacity(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including 20 mm dia PTMT Ball valve high pressure all as directed. 47 Allas per item No 46 above but 1000 ltr capacity 48 M & L for PU injection grouting by making necessary holes of 8 to 10 mm in concrete to a depth of about 75mm using proper electric hammer drill. Fix new nipples of 8 to 10mm using aluminum pipes using neat cement or M-Seal for proper anchorage. Carry-out pressure grouting using shaligrout 2k /equivalent) using a proper grouting pump. Seal the holes properly after the grouting nipples have been removed all as specified and directed by Engg -In Charge. 49 Material and labour for taking down old plaster and rendering 10mm thick in CM 1:6 on other than fair faces of brickor concrete surfaces finishing smooth and even and smooth without using extra cement making good match the old surface finish. 50 M&L two coat of OBD over a coat of primer on newly plastered surfaces of wall including cornices and preparation of surfaces. 51 M&L pre laminated particle board 12mm thick interior grade pre laminated one side with decorative choice lamination and other side balancing white lamination fixture with screws to frame work 52 Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge 53 M&L Screed bed or bedding layer 15mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and as directed by Engineer-in-Charge 54 M&L Rendering 10 mm thick in CM 1:3 on brick or concrete surfaces, finished fair and even for receiving wall tiles. 55 S&F glazed ceramic coloured tiles 300 x 200 x 7 mm thickon vertical surfaces, set and jointed in neat cement slurry and pointed in white/colour cement to match over 10 mm thick rendering (backing coat)in cm 1:3, complete all as specified and directed by Engineer-in-Charge. 56 M & L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm In floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge 57 S&F Vitrified ceramic coloured tiles 10mm thick (Square/ Rectangular) polished area of each tile not exceeding 0.36 Sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match 58 S&F in repairs health faucet 15mm size chromium plated standard size all as specified and directed. 59 Supply and fixed in repairs stainless steel wire cloth, 0.63mm nominal dia of wire and average width aperture 1.40mm and fixed with tinned tacks, or galvanized wire staples 60 M&L for chip and remove all damaged and de bonded concrete and plaster from the RCC slabs by manually or mechanically so as to expose the corroded reinforcement bars, removingthe debris with in a lead of 100 meters as directed by Engineer-in-charge. 61 M&L for supply and application of Nitobond EP (Manufactured by M/s Fosroc chemicals India Ltd) epoxy bonding agent over the old concrete surface complete all as specified and all as directed by Engineer-in-charge. 62 M&L for supply and application of rust remover/converter (Rebaklense RR of M/s Fosroc Chemicals India Ltd. or equivalent) or Amandur ,(manufactured by GK technocom) over the corroded reinforcement bar where ever micro concreting is required and cleaning the same after application complete all as directed by Engineer-in-charge. 63 M&L for plastering with Nitobond SBR (Styrene butadiene polymer bonding agent cum cement mortar/concrete modifier Manufactured by M/s Fosroc Chemicals India Ltd or equivalent) modified cement mortar (1:4) under the slab to an average thickness of 40 mm (applied in two layers not exceeding 20mm each) , including the cost of all materials rent of tools and labour charges etc complete all as directed by Engr-in-charge. 64 M&L Preparation of newsurfaces of ceiling and applying two coats of distemper oil emulsion on ceiling over a coat of primer over 3 mm thick wall care putty plastered and other surfaces with alkali resistant priming paint complete all as specified. 65 Taking down cement plaster of any description on walls incl raking out joints, hacking for key scrubbing down with water 66 M&L for plastering in CM1:6, 10 mm thick on interior walls finished even and smooth w/o using extra cement. 67 M&L for plasteringin CM 1:3, 5mm thick on ceiling finished even and smooth w/o using extra cement 68 M&L for two coats of Antifungal paint (Apex ultima Protek of Asian paint or Equivalent in approved Makes) over a coat of Exterior primer (Professional pack of Asian paints) over a coat of external wall care putty n.exc 2 mm thick on new or old prepared plastered external surfaces . 69 M&L Preparation of Newsurfaces of internal walland applying two coats of distemper oil emulsion on wall over a coat of primer plastered and other surfaces with alkali resistant priming paint over 3mm thick wall care putty complete all as specified. 70 M&L Preparation of oldsurfaces of internal wall by complete removal of existing treatment , and applying two coats of distemper oil emulsion on wall over a coat of primer plastered and other surfaces with alkali resistant priming paint over 3mm thick wall care putty complete all as specified. 71 M&L Preparation of old surfaces of ceiling by complete removal of existing treatment, and applying two coats of distemper oil emulsion on ceiling over a coat of primer, plastered and other surfaces with alkali resistant paint complete all as specified. 72 Demolition of brick work / PCC block masonry work built in cement mortar etc complete all as specified. 73 M&L Precast Concrete block masonry with solid blocks in PCC 1:3:6 type C1 (using 20 mm stone agg) exc 10 cm in width and setting in mortar 1:4with minimum compressive strength of 5N/ sq mm complete all as specified and as directed. 74 M&L for providing and fixing Gypsum Board 12mm thick in walls fixed with screw as per manufacturer’s instructions complete all as specified. 75 Dismantling in Wall and ceiling boards (fiber, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified. 76 M & L Anodised aluminium snap grid frame work (size of grid 605x 605) mm for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified all as specified and as directed. 77 M&L for providing and fixing Exposed metal frame ceiling with fire resistant calcium silicate board of siliceous and calcareous material reinforced with cellulose fiber for fixing in 600 mm x 600mm grid (Frame work for ceiling shall be measured and paid separately) fixed with screw as per manufacturer’s instructions complete all as specified. 78 Cleaning (mechanically)of sewage line/effluent drains 150/110 mm dia and disposing offthe sludge outside MoD land complete all as directed. 79 Removing the chokes in drains of WC/bath room/kitchen up to 1st manhole including cleaning of gully traps in single storey/ground floor of multi storeyed buildings, all as specified and directed. 80 Removing chokes in drains of WC/bath room/kitchen other than ground floor all as specified and directed. 81 Destruction of growth of weed plants with roots level on wall/ roof of building any height with weedicides such as Round up manufactured by Excel Chemical Industries and sprayed in and around roots and the place of possible growth of weeds as per manufacturer’sinstructions and making good the surfacescomplete all as specifiedand as directed. 82 Demolition of reinforced cement concrete in any position not otherwise specifically provided for 83 M& L for Precast RCC Cover slabs type B-1, 1:2:4 (20 mm graded stone aggregate as in slabs of drains including necessary form works. (Reinforcement bar will be measuredand paid separately). 84 M&L TMT bars 10mm dia and over cut to length bent to shape required, including, cranking, bending spirally for hooping for columns hooking ends and binding with mild steel wire (annealed ) not less than 0.9mm dia or securing with clips 85 Demolition of cement concrete in any position not otherwise specifically provided for complete all as specified and directed. 86 M & L for 1:3:6 Type C-2 (using 40 mm graded stone aggregate) for surface channels anddrains all as specified 87 Extra for forming fair finished drain or channel 30 Cminner girth in cement concrete ,using extra cement, including forms, moulds, mitered /stopped endsetc 88 Opening manhole of septic tank remove night soil and sediments including liquid by mechanical pumping into tanker lorry having cleaning internal surface with water and re-fix the manhole covers, complete all as specified and directed. Notes :-(i)Volume of the manhole will be worked out based on the depth or actual depth of sludge, whichever is less.(ii) Water shall be procured by the contractor for cleaning purpose. 89 Demolition of cement concretein ground floors and pavings n.exc 15 cm thickness (below or above ground level) 90 M&L for 100mm thick PCC ( 1:3:6)type C-2,using 40mm graded stone aggregate as in hard standing/path/sub basefinished to an even and fair surfaces. 91 M&L forming contraction (Dummy) joints 65 mm deep x 10 mm wide, filled with sealing compound Grade A. 92 Dismantling structural steel work incl doors, gates but excluding framed trusses. 93 S & FMS work in railings, balusters, posts and struts in fencing etc including cutting tops to shapeas directed, includingall necessary welding, drilling bolting or riveting etc and similar work conforming to FE 290 Gd E-165 complete all as specified 94 S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc. complete drilled for fixing of steel sheeting or other covering.Doors etc to be prepared for hanging with and including hooks and hinges, also fastening and fixing complete conforming to Fe-410W (Gde-E-250) 95 M&L for Point wiring for light point /fan point/Exhaust fan /Bell Pointwith 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with modular switch, modular plate and cover with GI box and earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. including dismantling /removing of burnt cable/making good surface asrequired . 96 M&L for submain wiring for 5 Amp socket outlet point on independent board with 2x 1.5 sqmm single core PVC insulated and unsheathed FRLS cable, 1100 volts grade IS -694 marked with multi standard copper conductors and earth continuity wire with similar 1x1.5 sqmm cable (incl connecting to earth dolly) drawn through and single core cable in surface/recessed medium class PVC conduit including dismantling /removing of burnt cable/making good surface as persiterequirement . 97 Supply and fixingsuitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular switch and 5/6A modular socket ,connection etc. as required atsitecomplete all as specified and directed (for Independent 5 Amp socket ) . 98 M&L for wiring for circuit along with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed steel conduit as required .wire 2x22.5 sq.mm + 1x2.5 sq.mm earth wire for 15/25 power plug/socket. 99 All as per item above but Supply and fixingsuitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 15/16 A modular switch and 15/16A modularsocket ,connection etc. as required atsitecomplete all as specified and directed( for 15/16 Amp Socket ). 100 M&L for wiring for circuit along with 4 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface /recessed steel conduit as required .wire 2x4 sq.mm + 1x4 sq.mm earth wire (for Ac & Geyser ) 101 S&F Electronic ceiling fan regulator, modular type stepped /socket type heavy duty suitable to work on 230 volts complete all as specified and directed. 102 Supply & Fixing piano type 5/6 amps switch on the existing Switch box including connection as required on site. 103 Supply & Fixing piano type 2 way 5/6 amps switch on the existing Switch box including connection as required on site. 104 Supply & Fixing piano type 15/16 amps switch on the existing Switch box including connection as required on site. 105 Supply & Fixing piano type 3 pin 5/6 amps socket outlet switch on the existing Switch box including connection as required on site. 106 Supply & Fixing piano type 6 pin 15/16 amps socket outlet switch on the existing Switch box including connection as required on site. 107 Supply & Fixing 5/6 Amodular switch on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 108 Supply & Fixing 15/25 Amodular switch on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 109 Supply & Fixing 3 pin 5/6 modular socket on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 110 Supply & Fixing 6 pin 15/25 modular socket on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 111 Supply & Fixing modular bell push on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 112 Supply and fixing 1 or 2 module base & cover plate on existing modular metal boxes etc as required. 113 Supply and fixing 3 module base & cover plate on existing modular metal boxes etc as required. 114 Supply and fixing 4 module base & cover plate on existing modular metal boxes etc as required. 115 Supply and fixing 6 module base & cover plate on existing modular metal boxes etc as required. 116 Supply and fixing 8 module base & cover plate on existing modular metal boxes etc as required. 117 Supply and fixing LED light fitting 1X20W,220V high efficiency(efficiency up to 100lm/w) polycarbonate batten bright light having high quality material and design, compact appearance simple and versatile in nature makes it as long lasting efficient solution, Make Crompton, Product code : CCS-102-20-30/40/65-SL-DP-NWHor GM/ Panasonic/Havells etc. 118 Supply and fixing LED light fitting 1X10W,220V high efficiency(efficiency up to 100lm/w)polycarbonate batten bright light having high quality material and design, compact appearance simple and versatile in nature makes it as long lasting efficient solution, Make Crompton, Product code : CCS-102-10-30/40/65-SL-DP-NWH or Havells /Panasonic/GM etc. 119 S & F in repairs LED 20W T8 Tube within built driver and efficiency of 100lm/w having glare free lighting distribution, double sided connection, housing made of high grade polycarbonate cover, 2.5 KV internal surge protection, IP20 ingress protection, PCB mounted on extruded metal plate. Make: Crompton model No LT8-20-865-(2) or equivalent in Havells/C&S/ Phillips/Bajaj. 120 S&F switch socket combination 5 Amp with PVC box suitable for 230 Volt on surface. 121 S&F switch socket combination 15 Amp with PVC box suitable for 230 Volt in surface 122 M&L switch socket combination2 in 1, 6/16 Amp flush type in existing switch box. 123 All as per item above but 6 Amp flush type in existing switch box. 124 M&L forbell AC 230 V Single pole ding dong type. 125 Supply and fixing angular type batten holder insulator body of PVC/ polycarbonate type suitable for 10/9 W Led bulb. 126 Supply and fixing fan condenser / capacitor of size 2.25/2.5 suitable for ceiling fan of any sweep. 127 Supply and fixingonly LED lamp of 9 watt, Make : Crompton/ Havells /Panasonic 128 S&F of 20 Amps 240 V , SPN Industrial type socket outlet, with 2 pole and earth ,metal enclosed plug top along with 20 A C Curve ,SP MCB , in sheet steel enclosure ,on surface or in recess with chained metal cover for the socket outlet and complete with connections ,testing and commissioning etc. as required . 129 Supplying and fixing 6 way, Double door single pole and neutral sheet steel, MCB distribution board,240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar ,din bar interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 130 Supplying and fixing 8 way, Double door single pole and neutral sheet steel, MCB distribution board,240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar ,din bar interconnections, powder painted including earthing etc. as required (But without MCB / RCCB/Isolator) 131 Supplying and fixing 4 way, Horizontal type , Three pole and neutral Dl sheet steel, MCB distribution board, 415V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar interconnections, powder painted including earthing etc. as required (But without MCB/ RCCB/ Isolator) 132 Supply and fixing of 5A to 32 A rating, 240/415V, 10kA C curve miniature circuit Breaker suitable for inductive load of single pole in the existing MCB DB Complete with connections, testing and commissioning etc ax required. 133 Supply and fixing of 5A to 32 A rating,240/415V, 10kA C curve miniature circuit Breaker suitable for inductive load of single pole and neutralin the existing MCB DB Complete with connections, testing and commissioning etc ax required. 134 Supply and fixing of 63 A rating,240/415V, 10kA C curve miniature circuit Breaker suitable for inductive load of Triplepole and neutralin the existing MCB DB Complete with connections, testing and commissioning etc as required. Make: IndoAsain, HSN Code: 8536, Cat. Nos.: 810107 or equivalent make of LT/ Havells. 135 M & L LED Square surface mounted Led Panel 12w, PDC housing and high translucent frosted plastic diffuser makes it a robust Luminar and efficiency up to 100lm/w. Make: Crompton, Model no LCDSPLN-R-12-CDL or equivalent make of GM/Havells. 136 M & L LED Round and Square recess mounted 12w LED edge lit slim down light with die cast aluminium housing finished in premium white coating and efficacy up to 100lm/w suitable for false ceiling. Make Crompton, Model no LSCRM-12W-WW/NW/ CDL or equivalent make of GM/Havells. 137 Dismantling and taking down ceiling fan any size for servicing by cleaning dust, filling cavities with filler and painting complete with synthetic enamel paint by spraying and re fixing the same in position, connecting and testingall as specified and directed. 138 M & L for carry out rewinding of ceiling fan motor of any size/ make including taking down from any height ,dismantling ceiling fan motor , removing old burnt winding wire, cleaning the armature thoroughly and replacing the same with new enameled copper wire of adequate size/gauge including class B insulation, varnishing heating etc, reassembling and removing the old painting and providing newpainting to ceiling fanscompletewith synthetic enamel Grey paintby spraying using machine including filling cavities with filler one coat after cleaning all dust making the surface in good finishes etc , testing, re-fixing the same in original position complete all as specified and as directed by the Engineer - in - Charge.Note: Rate include the taking down the ceiling fan and deposited to MES store for checkingand repairing) 139 All as per Item above but for the Exhaust fan of 300 /450 mm sweep sizes: 140 S & F in repairs of LED 36W surface full lit luminaire with glare free uniform illumination with longer life and less maintenance available in 2x2 ft (> 100 lm/w).Make: Crompton, Model No LCTLSNE-36-FO-WW/TL/CDL or Havells /C&S/ Phillips/Bajaj. 141 Supply andLayingGI tubing medium grade of size 50 mm with and including all fittings such as bends, elbows, tees, short pieces etc complete in trenches of following sizes after taking down old unserviceable GI pipes all as specified and directed by Engr in charge. Note- Excavation & earth work will be measured & paid separately. 142 All as per item above but 40 mm bore 143 All as per item above but 25 mm bore 144 Supply & Fixing of Size 50 mm GI tubing medium grade withand including all fittings such as bends, elbows, tees, short pieces etc complete on wall and ceiling or laid in floors after taking down old unserviceable GI pipes all as specified and directed by Engr in charge. 145 All as per item No 4 above but 40 mm bore 146 All as per item No 4 above but 25 mm bore 147 All as per item No 4 above but 20 mm bore 148 Repairs to leakage /damaged G.I. pipe of size 50/40 mm bore including necessary excavation, returning, filling in removal/ pump out the line water cutting out GI pipes at both ends replacement ofGI Pipe and jointing with new fittings accessories such assockets, tees, reducers, Nipples ,Bends etc. all asdirected by Engr- in- charge. Note:- G.I. pipe length will be measured and paid separately under relevant item of sch A 149 All as per item above but 25/20 mm bore 150 Supply and fix in repairs gun metal gate valve of size 50 mm ISI marked with iron wheel head screwed both ends all as directed. 151 All as per item above but 40 mm bore 152 All as per item above but 25 mm bore 153 All as per item above but 20 mm bore 154 All as per item above but 15 mm bore 155 S&F in repairs un plasticized PVC pipe, 25mm bore of pressure rating 10 Kg/ Sqcm with all fittings, fixed to walls, ceilings or in floors complete with snap clips hooks etc and taking out old unserviceable one all as specified an as directed 156 All as per item above butof size 20 mm bore dia 157 Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft / loose soil forlaying/taking out GI pipe line all as specified and directed. 158 Returning filling in including spreadingleveling watering and well rammingin layer not exceeding 25 cm in soft/loose soil all as specified and directed. 159 Removing excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mabove the starting point all as specified and directed. 160 M & L for removing the dirt, sediments, silt, algae, fungi etc, from the bottom and walls of the inside of the RCC Under Ground Sump of10,000 Ltrscapacity by dewatering the sump and cleaning the complete inner surfaces by rubbing / scrapping by wire brush to removethe sludge, washing with bleaching powder solution and then with water and draining out sludge, water completely including applying one coat of white wash to all the inner surfaces, and details of tanks like date of cleaning ,capacity of tanks etc shall be written on the outside of the tank with synthetic enamel paint with lettersize 20 cm high in white color , over a black backgroundof size 100x60 cmand charges included for pump set for de watering incl operator all as specified anddirected 161 M&L for removing the dirt, sediments, silt, algae, fungi etc, from the bottom and walls of the inside PVC Service tanks kept on roof top of buildings or on stagings, cleaning the surface using brush and other cleaning materials such as bleaching powder as required including writing the capacity of the tank and date of cleaning with white enamel paint over black back ground all as specified and directed for the following capacity of tanks at different locations on Technical/Residential Buildings all as specified and directed by Engr-in-Charge. 162 2000 Ltr capacity 163 1000 Ltr Capacity 164 500/300 Ltr capacity 165 S&F in repairs float Valve 40mm bore (Ball brass valves) high pressure type with polyethylene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed and taking out old unserviceable one all as specified and directed 166 All as per item above but of size 25mm bore 167 All as per item above but of size 20mm bore 168 S&F in repair/replacement HDPE Tank cover suitable for 300 to 1000 Litr capacity and taking out old unserviceable one 169 All as per item above but for 2000Ltr capacity tanks 170 M&L for repair/replacement ofFoot valve of size 50mmbrass heavy duty including taking up the suction pipe and re-fixing the same after replacement of foot valve in to the sump for proper functioning of pump and taking out old unserviceable one all as specified and directed 171 Dismantling of Mono-block Pump set from the existing position for servicing including opening the pump replacing the unserviceable ball bearings of suitable size for capacities up to 5 HP including greasing complete all as specified and directed 172 Repairs and servicing of Electric chlorine dozing Pump/ system Make Sathya sai Aqua Pura Services with Ant siphon valve including servicing of pump and motor with repair/ replacement of unserviceable parts like piston, stroke controller, suction and delivery tubing, PVC foot valve, nozzle, solution tank inlet, PVC water tubing 15mmbore, gate valve 15mm size etc, complete all as specified and directed. 173 M&L for cleaning of pump sets starter panel after dismantling the incoming and outgoing connections from MCCBs /MCBs and replacing the old unserviceable gland, lugs, nuts &bolts, push buttons, indicating lamps, supporting insulators etc, and checking the serviceability of MCBs cables and earth continuity conductor including replacement of worn out and unserviceable minor accessories all as specified and directed 174 M&L for Replacement of unserviceable DOL Starter suitable for motor up to 5 HPincluding connections 175 M&L for Repairing the old Valve pit of dimension 60x45x45 cm by taking out plaster and rendering with 10mm thick CM(1:4) including PCC (1:3:6) TYPE C2 on base, brick work inCM (1:4) as required and applying two coats of white wash on plastered surface including applying two coats of synthetic enamel paint over one coat of red oxide primer over steel surfaces after preparation, complete all as specified and directed 176 M&L for painting pump set including preparation old surfaces and painting with two coats of synthetic enamel paint over a coat of red oxide primer including marking the signs, letters, Nos on the pump setof capacity up to 2HP all as specified and as directed. 177 M&L for painting of old painted GI pipe of any size on the external surfaces after preparation, located in and out of Pump House, by scrapping and cleaning of external surfaces and applying two coats of Sky Blue paint over a coat of red oxide primer complete all as specified and directed. 178 Dismantling , taking out complete burnt winding wire of submersible motor including cleaning of statorslots replacement of defective parts and rewinding with existing type & gauge ofcopper wireas per motor capacity and using new insulation material such as insulating paper sleeves etc. replacement of submersible cable as required length complete all as directed of rating 1.5/2HP Single phase 179 Repairs to leakage /damaged G.I. pipe of size 80 to 100mm bore including necessary excavation, returning, filling in removal/ pump out the line water cutting out GI pipes at both ends replacement ofGI Pipe and jointing with new fittings accessories such assockets, tees, reducers, Nipples, Bends etc. all asdirected by Engr- in- charge. Note:- (i) G.I. pipe length will be measured and paid separately under relevant item of sch A 180 Material Labour for fixing Mechanical joint suitable 80 mm dia GI pipe, fabricated and made out of MS sheet of thickness 6/8 mm including welding work, rubber gasket, nuts, bolts and washers complete all as specified and directed by Engr in charge. 181 Comprehensive Maintenance, Servicing and carrying out periodical service to DG set along with AMF panel or standard panel like carry out oil service and routine checkup/maintenance as per manufacturers schedule, checking complete system of lubrication, cooling systems, air intake systems, fuel systems, exhaust systems, DC/AC electrical systems in DG Set as well as in AMF/Standard Panel, tightening bolts and nuts in engine and alternator related systems, etc and repairs including material for renewal/ replacement of minor defective parts of like connectors, MCBs , phase indication lamps etc for following capacity of DG sets all as specified and directed by Engr in charge. 182 35 KVA with AMF Panel installed at 14 ASC, AF Kakkanad 183 20 KVA with AMF Panel installed at 14 ASC 184 Note:The spares to DG Sets items as listed below as SUPPLY ONLY will be used whenever required only and it shall measured and paid separately under respective items. 185 The rate is inclusive of all items as required at site except those items as SUPPLY ONLY below to keep the DG Set along with AMF / Standard panel on monthly basis complete all as specified and as directed by Engr-in-Charge. 186 The contractor should attend any complaint / breakdown immediately on call basis and even no. of times without any extra cost. 187 Contractor should submit the inspection / maintenance report of every visit in spite of no of visits during breakdown calls including mentioning the status of DG Sets and spares any replaced 188 The old unserviceable spares replaced under comprehensive maintenance i.e. in sl No 02 of above BOQ is the property of contractor for which credit shall be deducted under respective items in schedule of credit. 189 All AMF panels and standard DG set panels should be well cleaned with CTC solution checking all the electrical connection and tighten for any loose connection. 190 Supply and replace of heavy duty diesel engine oil of 20W40 grade for DG Sets having capacities varying from 15 KVA to 35 KVA complete all as specified and as directed. 191 Supply only Lub Oil Filter for DG set 15 KVA to 35 KVA 192 Supply only fuel filter forDG set 15 KVA to 35 KVA 193 Supply only Oil pressure gauge for DG set of any size/make 194 Recharging of Battery 12 Volts , up to180 AH any make / type by replacing electrolyte including replacement of unserviceable terminal posts , to the required standard complete all as specified andas directed . 195 Diesel hose of size 5/16 all as directed 196 Battery terminals one end socket and the other end clamp type including brazing work and applying jelly over the battery terminal and pole all as directed by the Engr in charge 197 Water hoses complete set of engineDG sets of cap 15 to 35 KVA 198 Repairs to 12 V self starter of DG set engine by dismantling, removing and replacing the old defective/worn-out bearings, servicing including replacement of carbon brush, bendix drive, cleaning commutator in armature etc assembling and testing for satisfactory function all as directed. 199 Supply only auxiliary contactor suitable for AMF panel of 15 to 35 KVA DG set 200 Supply only power contactor suitable for AMF Panel of 15 to 35 KVA DG set 201 Supply, install, testing & commissioning in repairs DC relay card/ PLA relay 12/24 volt DC for DG set any capacity including making all electrical connections and checking by running the DG set for 02 hours complete all as specified and directed by Engr-in Charge, 202 Supply and mixing water coolant in radiator water of DG Sets having capacities varying from 15 KVA to 320 KVA complete all as specified and as directed. 203 Repairs to door of acoustic enclosure of DG set cap 20 KVA by taking down and replacing the door hinges and door lock including all M&L and as directed. 204 Supply only distilled water into battery capacity of 12/24 Volt 88/90/180 AH all as specified and as directed by Engineer-in-Charge. 205 Taking out old burnt out Automatic voltage regulator from DG setcapacity 15 KVA to 35 KVA alternator and replace with new AVR and includingtesting and checking voltage regulation ofthe DG set on full loadfor its satisfactory performance complete all as specified and directed by Engineer-in-Charge:- 206 M&L for dismantling of complete radiator assy for DG Set capacity 15KVA to 35 KVA from engine and taking out all, de scaling rusty, sludge and muddy particles inside the radiator by using of sodium hydroxide with water pressure cleaning complete, changing of radiator fan belt if required and re-fixing the radiator assy on its existing position and testing complete for its satisfactory performance with entire satisfaction of Engineer-in-Charge:- 207 M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm buried directly in ground level with top edge of earth plate at a depth not less than 1.5m below ground level connected to and including galvanized iron strip 25mm x 4mm as earthing lead by means of bolts, nuts, check nuts and washers etc made of GI and connected to earthing test point all as shown in electric plate No. 3 of SSR indicated and testing on completion including excavation and earth work in any type of soil/rock, PCC (1:3:6) type C-1 earthing chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforced with welded steel wire babric (APM) weight not less than 4 Kg/ Sqm, funnel with GI watering pipe of 20mm bore medium grade, wire mesh and lugs, GI protection pipe of 40mm bore medium grade 7.5 m long test point etc complete all as specified and as directed by Engr-in-Charge. 208 Providing and fixing 25mm x 5mm G.I strip in 40 mm Dia G.I pipe from earth electrode including connection with G.I Nut, bolt, Spring, Waher excavation and refilling etc. as required. 209 Supply & Fix in replacement MCB SP 6 - 32 Amp, C-curve, 415 volt AC complete all as specified. 210 Supply & Fix in replacement MCB SPN 6 - 32 Amp, C-curve, 415 volt AC complete all as specified. 211 Supply & Fix in replacement MCB TPN, 40 -63 Amp, C-curve, 415 volt AC complete all as specified. 212 Supply & Fix in replacement AMF controller, three phases, 50 Hz, AC, auto/manual/test/off mode with necessary display complete all as specified. 213 Material & Labour for dismantling the alternator of DG Set of capacity 20 KVA to 75KVA from its base by using chain and pulley after removing the coupling with the engine, removing all nut, bolt with washer and all electrical connection of the alternator, shifting the alternator to workshop by crane and vehicle, opening into parts, checking all winding like main stator/rotor winding, exciter stator/rotor winding. Rewinding the main rotor and exciter rotor by using the “F” class insulation and existing gauge and type of magnet wire which was on original motor, varnishing, heating, drying, greasing the bearing including replacement unserviceable bearing ,re-fixing the complete including connection to the terminal box of the alternator at workshop and shifting the same to the site, fixing the alternator to its base carefully by using chain and pulley, connecting it with existing engine including checking the alignment of alternator with engine connecting all electrical connection of the alternator and testing the DG set “OFF/ FULL LOAD” , matching to the existing range of RPM of the engine output voltage for 415 volt and testing complete all as per the direction of Engineer In Charge. 214 Material & Labour for taking down unserviceable heat insulation from exhaust piping and providing new heat insulation to exhaust pipe using 50 mm thick mineral wool inside the container & up to the exhaust stack. The insulation shall be cladded/ covered with 24G aluminium sheet. Pipe length shall be maximum up to12 Meter long from engineincluding necessary welding works, cladding works with wire mesh and aluminium foil, replace unserviceable supporting MC,angle iron 50 mm X 50 mm X 6 mm, suitable size flange, nut, bolt and washers as required includingweather cowl complete all as specified. 215 Material & Labour for dismantling carefully fuel injection pump (FIP) up to 6 cylinders engine of DG set and transporting to workshop, opening into parts, for maintenance, servicing, overhauling, tuning and calibration, adjustment of nozzle pressure and other controls, replacement of unserviceable spares, re-assembling, re-fixing the FIP on its original position including to and from conveyance charge from site to workshop and back complete all as specified. 216 Material & Labour for dismantling exhaust manifold from the engine to detect the smoke leak, clean the manifold including welding works, replacement of unserviceable spares, packing, bellows, nut, bolt, washers, insulators, etc. reassembling and re-fixing on its base, testing by running the DG set No LOAD/FULL LOAD complete all as specified. 217 S&F in repair 1.5 Sqmm three core PVC insulated, unsheathed multi stranded copper conductor flexible cable 1100 volts grade complete all as specified and directed by Engr in Charge. 218 M&L for preparation of old paintedsurfaces of the DG set and fuel tankof following capacity by cleaning oily and greasy spots using CTC and material and labour for one coat of synthetic enamel paint using spray machine to the fuel tank and one coat of heat resistance paint to Engine / alternator complete all as specified and directed. 219 Note: - Colour code to be followed as under:-(i) Engine body - OG.(ii) Alternator - Siemens grey(iii) Fly wheel guard - Red(iv)Radiator -Black(iv)DG set canopy/complete body with two coats of superior qualitysynthetic enamel paint using spray gun (Area of painting not exceeding 3 sqm) including writingof incoming/outgoing feeder with letters, MES/SM Nos etc completeall as specified. For DG Set capacity 15 KVA to 35 KVA 220 M&L for disconnection of Diesel Oil tank with inlet and outlet diesel pipe line hose/pipe and cleaning of complete oil tank and drain out slug, muddy oil particle complete and re-fixing after at the same place and connecting complete with existing system including marking of tank showing the capacity in Ltrs and replacement of transparent PVC pipe complete all as directed by Engineer-in-Charge:-For DG Set capacity15KVA to 35KVA 221 Supply, install, testing & commissioning in repairs controller- Procom DGC-6D Auto Mains failure control Module including Display, replacing contactors/Connectors and making all electrical connections good and renewed for up to DG set 35 KVA as per existing make complete all as specified and directed by Engr-in-charge. 222 M & L for Servicing of split type Air-conditioning unit comprising Indoor and Outdoor unit of any make/type having capacity 1.0/1.5/2 TR including attending breakdown including required tools and plants,minor electrical sparer like small piece of wire, insulation tape , screws required to rectify the complaints by replacing the spare partsin technical andresidentialbuildingat 14 ASC Kakkanad. Note: Spares required is measured and paid as respective items in Schedule A and all specified and directed by the Engineer - In - Charge. 223 Supply and charge refrigerant gas R-32/R-410 at site including testing all as specified and as directed by Engineer in charge . 224 Supply only Capacitor 36/40 MFD suitable for 230 V 50 HZ AC supply all as specified and as directed by Engineer in charge. Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron) 225 Supply only Capacitor 50/60 MFD suitable for 230 V 50 HZ AC supply all as specified and as directed by Engineer in charge. Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron) 226 Supply only Capacitor 80/100MFD suitable for 230 V 50 HZ AC supplyall as specified and as directed by Engineer in charge . Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron) 227 Taking out existing burnt fan motor single phase 230 Voltfrom the unit at site by carefully dismantling the same, taking out burnt copper winding and rewinding the same with super enameled copper winding wire of appropriate size and gauge, including replacement of defective bearing and bushes of existing size and standard make including varnishing to copper winding re-assembling the motor and testing the motor at medium and full load complete for the followingall as specified and as directed by Engineer - in - Charge. 228 Splittype AC capacity up to 1.5 Ton 229 Split type AC 2.0 Ton Capacity 230 Taking out old unserviceable PCB and replace the same with new PCB at site suitable for window/split type AC of capacity 1/1.5/2 TR all as specified and directed by Engg-in-charge 231 Taking out carefully existing defective sealed unit compressorSupply & fixing factory made rotary type sealed compressor unit same as per existing model and make including charging the gas and testing & commissioning under normal condition of following rating complete all as specified and directed by Engineer - in - Charge. 232 (a) Split type Ac 1.5/2.0 Ton capacity 233 Removing the damaged insulation of suction and discharge line & Supplying and fixing new Thermal sleeve insulation for suction line and discharge line including providing hard plastic tape over the thermal insulation of split type A/C 1.5 / 2.0 Ton capacity etc complete all as directed by Engineer - in - Charge. 234 M&L in replacement of old unserviceable remote by providing new remote suitable for window type/ split type AC of any capacity/any make as specified and directed by Engineer in Charge. 235 Supply only new capacitor of Fan motor of 4 MFD complete all as directed by Engineer - in - Charge. Make: USHA / ASIAN / TESLA / KELTRON / KEIL/ EPCOS. 236 Supply only new capacitor of Fan motor of 10 MFD complete all as directed by Engineer - in - Charge. Make: USHA / ASIAN / TESLA / KELTRON / KEIL/ EPCOS. 237 Suply only split type AC indoor unit oscillation motorcomplete all as directed by Engineer - in - Charge. 238 Supply only thermostat for split type AC 1.0/1.5/2.0 complete all as directed by Engineer - in - Charge. Make: INDFOSS / RANTROL / ANNAPURNA. 239 Supply & fix in replacement of factory made MS bracket or Stand duly painted suitable for outdoor unit of split AC including making good disturbed surfaces etc. , all as specified andas directed. 240 M & L Removing the split A/c unit from existing position, of capacity 1.5/2.0 Ton of any make and refix the same in other location by fixing the indoor and outdoor unit in position on fixing on wall/ floor as directed including piping refix the insulation, Gas charging filling the cavities on wall setting of grills alignment complete including, testing & commissioning to the entire satisfaction of Engineer - in - Charge. 241 Supply and fixreplacement 240V 20 Amp singlepole and earth enclosure with a two pin and earth plug and socket complete with one single poleMCB20 Amp SPAll as directedEIC .Make: Legrand , Cat No: 6078 41/Equivalent in L & T/Indo Asian. 242 Taking down the old sub main wiring and M/L for new sub main wiring with 2 run single core 4.0 sq mmPVC unsheathed copper multi stranded, FRLS conductor drawing into and including PVC conduit medium grade of size not less than 20 mm dia with all fittings and fixtures like L- bow, saddles etc of white/lvorycolour PVC conduit including multi stranded copper earth conductor 4.0 sq mm one run as earth continuity conductor all as directed by Engineer in Charge. 243 Supply and fixing in replacement of LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Make: Havells Cat Part No ENDURAPEARLNEOSL45LED757PASYTOPC or its equivalent make of Crompton/Bajaj/HPL/GM. 244 Supply, fixing, connecting and testing in replacement of 150 Watt LED flood light 230 Volt AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Make: Havells Cat No JETAIRISFLS150WLED757PSYMLTG or its equivalent make of Crompton/GM/HPL. 245 Supply and fixing in replacement to ground with suitable pole mounting with OD of 76 mm, connecting and testing 40 Watt LED Post Top Luminaire, 230 Volt AC outdoor type with decorative post top for 360° indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Make: Crompton Cat Part No LPTO-40-CDL/M or its equivalent make of Havells/Bajaj/GM/HPL. 246 Supply and fixing passing through pole cable 3 core PVC insulated unsheathed multi stranded copper conductor of size 2.5 Sqmm from junction box to lightfitting all as directed by EIC. Make: Havells/Finolex/Poly cab. 247 Supply & fixing in replacement of transparent cover type street light junction box of size 168 mm x 253 mm x 115 mm made of high quality thermoplastic type with hinged and 4 Nos DIN mounted terminal suitable for 10 Sqmm XLPE cable, IP-66 (Dust and power jet Proof according to IEC 60529) , shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact (IK 08) totally insulated (Class II ) made of halogen and silica free recyclable material, UV resistant having high grade gasket made of poly-urethane with copper bus bar 25 x 5 mm -04 strip, one noMCB SP 6 Amps with locking arrangement and 2 Nos M40 size cable gland and one M32 size gland suitable up to, 10Sqmm cable etc and fixing to the street light pole with 02 Nos, 25 x 3 mm thick MS clamps, nuts & bolt, etc. complete all as specified and directed. Make: Hensel Cat Part No KG 9002 or its equivalent make. 248 M & L for removal of existing treatment from PCC poles and applying two coats of weather proof exterior emulsion paint on old painted surface over a coat of primer, complete all as specified and directed by Engineer-in-Charge. 249 M&L for cleaning of feeder pillar/ panel after dismantling the Incoming and outgoing connections from MCBs and replacing the old unserviceable Gland, lugs, nuts & bolts, push buttons, indicating lamps, supporting insulators etc., and checking the serviceability of MCBs, cables and earth continuity conductor including replacement of worn out and unserviceable minor accessories all as specified and directed by Engineer-in-Charge.Note: Spares / materials charge for repair/replacement of worn-out parts shall be measured and paid separately under relevant items. 250 S & F in replacement of MCCB 4 Pole 100-125 Amps 415V 16 KA 251 S & F in replacement of MCB TPN63Amp, 4 Pole, C Curve 252 S & F in replacement of MCB DP 32-40Amp, C Curve 253 S & F in replacement of MCB SP 6 to 32Amp, C Curve 254 Comprehensive Maintenance, Servicing and carrying out periodical service to Voltage Stabilizer, servo type of capacity 63 KVA, 3 phase, 50 c/s, AC including along withrepairing/ replacing of all defective parts such as nut-bolts, washers and all other minor accessories as required at siteall as specified and directed by Engr in charge. Notes: 255 (a) Any additional parts required to be replaced will be measured and paid separately as Supply only against appropriate item of schedule. However labour element and painting involved in replacement are included in quoted rate against this item. 256 (b) Any minor repairs involved to make the voltage stabilizer functional if notified by the Engr-in-Charge shall be carried out by the contractor without any extra cost to the department. (c) Following parts (if renewed) shall be measured and paid separately under appropriate items at Supply only rates and unserviceable parts retrieved through replacement shall be measured under Sch of credit. 257 Disconnecting the complete unit of Servo Controlled voltage stabilizer of capacity 63 KVA, 3 phase, 50 c/s, AC supply of Make- Volteck or as per existing make and overhauling of the same by cleaning, servicing all serviceable accessories including painting with two coats of synthetic enameled paint externally after rubbing of old loose paint along with writing SM No. and capacity on the face of stabilizer and making all connections at both ends including providing lugs on existing cable and testing on full load after completion of repair / overhauling work complete all as specified and directed.NOTE: - (i) Supply only spare parts shall be measured and paid separately under relevant items of this schedule. (ii)Transportation charge / labour charge during the repair of voltage stabilizer from the site to workshop are included in the items of this schedule 258 Supply only following spare parts of 63KVA capacity Servo Voltage Stabilizer complete all as specified and directed: - 259 AC synchronous motor single phase, 50 Hz, 240 volts Make:UNI STEP or equivalent make suitable for volteck servo . 260 Variable auto transformer (Variac). 261 Sensing Transformer. 262 Carbon brush with holder complete. 263 Solid state sensing circuit. 264 RC Net work. 265 PCB connector. 266 Gear big. 267 Carbon fingers. 268 Variac Control CT. 269 Main Bushing with brass rod (insulator & rod). 270 High low cut off relay. 271 Series transformer. 272 Wiring Set. 273 Gear small. 274 Transformers oil filtering with test 275 Replacement of electronic control board 276 Fixing of top cover after repair and testing up to entire satisfaction of Engr in Charge. 277 Supply, installation, testing and commissioning of street light timer control panel, on pole/wall/floor mounting made out of CRCA steel sheet duly powder coated with locking arrangement, including internal wiring complete with bypass arrangements as per manufactures recommendation and design complete all as specified and as directed.Make: Havells Cat Part No IHXTS09120 or its equivalent make of above specification. 278 S&F bracket for fixing to street light poles, made out of suitable dia for fitting of LED street light fittingsmedium grade GI pipe bend to shape inclusive of one primer coat, one under aluminium coat and one aluminium finishing coat of paintall as directed by the Engineer-in- Charge. Make: TATA / Jindal / Surya Praksh. 279 Supply, install, test and commissioning of outdoor type double door LT Feeder pillar box made out of 3.15 mm thick CRCA sheet outdoor type totally enclosed weather dust and vermin proof as per IS , CPRI Approved with front opening suitable locking arrangement having copper bus bar of 300 Amp capacity for RYB and half for neutral and insulated with insulators, including connecting incoming and outgoing cables necessary PCC 1:3:6 in foundation and made out of 50 mm x 50 mm x 6 mm angle iron grouted at ground above 30 cm from ground level comprising of the following etc complete all as specified and directed by Engineer-in-Charge. Note: Cost of necessary internal wiring from bus bar to MCCBs/MCBs/Enclosure connections etc shall be deemed to be included in the unit rate. 280 Incoming:(a) MCCB 200 Amp 4 pole 36 KA Ics=100% of Icu with spreader & rom -01 No. (b) Indication Lamp Red/Yellow - 03 No (c) SP MCB 6A -03 Nos (d) MFM Meter with CT- 01 No (g) Provision for installation of KESB 3 Phase meter with necessary accessories. 281 Outgoings.(a) 125 Amp 4P MCCB 25 KA Ics=100% of Ics with spreader & rom -01 No (b) 100 Amp 4P MCCB 25 KA Ics=100% of Ics with spreader & rom -01 No (c) 63 A 4P MCCB 25 KA Ics=100% of Ics with spreader & rom -01 No.(d) 32 Amp 4 MCCB 16 KA, Ics=100% of Ics with spreader & rom -01 No. 282 M & L for re-filling of chemicals (minimum 25-30 ltrof Bentonite chemical / Graphite compound for each earth pit) in existing chemical earthing at technical area for achieving satisfactory earthing value with comprising of the Bentonitecomponents including necessary excavation/drilling for lift of cylindrical copper tubes from the ground and re-fixing the same by using Rig machine and providingenclosure with heavy duty plastic cover having locking arrangement including changing of electrode with pure copper chemical earthing electrode (length ofRod : 3 mtr Approx) for excellent conductivity & work efficiencycomplete all as specified and as directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 9
20.
Agriculture #10727534 Price Bid
Tender For Renovation Of Western Side Jetty At Kiltan; 1 Abstract-IDismantling of existing damaged concreates of slab, longitudinal beams, cross beams hand rails, electric posts ,low landings, screen walls, midtide beams etc and transporting the materials to the department stack yard as instructed by EIC leaving no brocken concrete pieces on the sea bed including hire charge of tractors, cost hire charge of required heavy machineries likeconcrete cutter, demolition hammer, breaker, etc of cost of labours complete. 2 Providing and laying design mix concrete of RCC M40 grade in accordance with IS 456 (Latest Edition) using coarse aggregate from mainland quarry, M-sand confirming to IS and 43 grade Ordinary portland cement confirming to IS 455, adding silica fume and approved plasticizer as per design mix as instructed by EIC, including cost of all materials- cement, stone chips, M-sand, cost of centering and shuttering, cost of all labour charges, mixing, conveying, placing, consolidation, screening and washing of coarse aggregate and M- sand, transportation charges of all materials to the Work Site at Kiltan, hire charges and running charges of Mixer Machine, vibrator, consumables and all other equipments, cost of minor tools etc. complete. 3 Providing and laying design mix concrete of RCC M40 grade in accordance with IS 456 (Latest Edition) using coarse aggregate from mainland quarry, M-sand confirming to IS and 43 grade Ordinary portland cement confirming to IS 455, adding silica fume and approved plasticizer as per design mix in cast-in-situ for hand rail posts, handrails and light post etc as instructed by EICincluding cost of cement, stone chips, M-sand,Silica fume & Plasticizercost of all labour charges, mixing, conveying, placing, consolidation, screening and washing of coarse aggregate and M- sand, transportation charges of all materials to the Work Site at Kiltan, hire charges and running charges of mixer machine, vibrator, consumables and all other equipments, cost of minor tools etc. complete. 4 Centering and shuttering for Hand railposts, handrails and lighpost etc including cost of all materials (Cement, M Sand, 20mm chips), form work, transportation charge of materials to the site, hire charge of mixer machine, vibrator and minor tools as per the direction of EIC etc complete 5 Supply, deliver and transportation ofsteel of grade Fe 500 D HSCRM / HCR / CRS or equivalent confirming to IS 1786 with corrosion resistant element for Fabrication and fixing of reinforcement in superstructure worksas per the directions ofEIC, including cost of fabrication & fixing, cost of corrosion resistant deformed bars, all handling charges, cutting, bending, lapping, tying and welding in position wherever necessary with black 18 SWG annealed binding wire, all labour chargs, cost of binding wire, transportation charges for all materials from to worksite at Kiltan, all T&P required for the work and minor tools etc. complete. 6 Providing and laying design mix concrete of PCC M30 grade in accordance with IS 456 (Latest Edition) using coarse aggregate from mainland quarry, m-sand confirming to IS and 43 grade Ordinary portland cement confirming to IS 455, adding silica fume and approved plasticizer as per design mix in cast-in-situ for wearing coat etc.as instructed by EIC including cost Silica fume & Plasticizer , cement, stone chips, M sand, cost of all labour charges, mixing, conveying, placing, consolidation, screening and washing of coarse aggregate and m-sand, transportation charges of all materials to the Work Site at Kiltan, hire charges and running charges of Mixer machine, vibrator, consumables and all other equipments, cost of minor tools etc. complete. 7 Applying two coat of ready mixed acrylic plastic emulsion paint (Exterior emulsion) antifungals over the primer coat on the hand rails, posts, hand rails, light posts and on the right sides of the newly concreated jetty superstructure (longitudinal beam, deck slab side) as per the direction of EIC including cost of all the required materials and labour charges etc. complete. 8 Providing and fixing 10T and 20T bollards on the both side of the jetty for arresting the vessels, boat with ropes for embarkation/disembarkation of passenger and cargoes excluding the cost of bollard with its fittings, transportation charges, minor tools, labour charges etc., complete. 9 10T 10 20T 11 Abstract-IIDismanting of existing damaged concreates of slab, longitudinal beams, cross beams hand rails, electric posts ,low landings, screen walls, midtide beams etc and transporting the materials to the department stack yard as instructed by EIC leaving no brocken concrete pieces on the sea bed including hire charge of tractors, cost hire charge of required heavy mechinaries likeconcrete cutter, demolition hammer, breaker, etc of cost of labours complete. 12 Providing and laying design mix concrete of RCC M40 grade in accordance with IS 456 (Latest Edition) using coarse aggregate from mainland quarry, M-sand confirming to IS and 43 grade Ordinary portland cement confirming to IS 455, adding silica fume and approved plasticizer as per design mix as instructed by EIC, including cost of all materials- cement, stone chips, M-sand, cost of centering and shuttering, cost of all labour charges, mixing, conveying, placing, consolidation, screening and washing of coarse aggregate and M- sand, transportation charges of all materials to the Work Site at Kiltan, hire charges and running charges of Mixer Machine, vibrator, consumables and all other equipments, cost of minor tools etc. complete. 13 Supply, deliver and transportation ofsteel of grade Fe 500 D HSCRM / HCR / CRS or equivalent confirming to IS 1786 with corrosion resistant element for Fabrication and fixing of reinforcement in superstructure worksas per the directions ofEIC, including cost of fabrication & fixing, cost of corrosion resistant deformed bars, all handling charges, cutting, bending, lapping, tying and welding in position wherever necessary with black 18 SWG annealed binding wire, all labour chargs, cost of binding wire, transportation charges for all materials from to worksite at Kiltan, all T&P required for the work and minor tools etc. complete. 14 Providing and laying design mix concrete of PCC M30 grade in accordance with IS 456 (Latest Edition) using coarse aggregate from mainland quarry, m-sand confirming to IS and 43 grade Ordinary portland cement confirming to IS 455, adding silica fume and approved plasticizer as per design mix in cast-in-situ for wearing coat etc.as instructed by EIC including cost Silica fume & Plasticizer , cement, stone chips, M sand, cost of all labour charges, mixing, conveying, placing, consolidation, screening and washing of coarse aggregate and m-sand, transportation charges of all materials to the Work Site at Kiltan, hire charges and running charges of Mixer machine, vibrator, consumables and all other equipments, cost of minor tools etc. complete. 15 Applying two coat of ready mixed acrylic plastic emulsion paint (Exterior emulsion) antifunges over the primer coat on the hand rails, posts, hand rails, light posts and on the right sides of the newly concreted jetty superstructure (longitudinal beam, deck slab side) as per the direction of EIC including cost of all the required materials and labour charges etc. complete. 16 Providing and fixing 10T and 20T bollards on the both side of the jetty for arresting the vessals, boat with ropes forembarkation/disembarkation of passenger and cargoes excluding the cost of bollard with its fittings,tranportation charges, minor tools, labour charges etc., complete. 17 10T 18 20T
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Lakshadweep View Result →
22.
Rural Development #10331989 Price Bid
Supplying Various Types Plumbing Material At. Grampanchayat Kharabwadi, Tal. Khed, Dist. Pune , 101 Lw+ Pidiproof-1Ltr , 101 Lw+ Pidiproof-20Ltr , 3.15Mm 6013 Jack , 3.15Mm 6013 Mangalam , 301 Urp Pidicrete-5Kg , Ad Spanner 10 V , Ad Spanner 10-250Mm T , Ad Spanner 12 V , Ad Spanner 15 V , Ad Spanner 8 V , Ambadi (Jute) , Ball Cock 1 , Ball Cock 1/2 , Ball Cock 3/4 , Ball Valve Brass 1 H , Ball Valve Brass 1/2 , Ball Valve Brass 1/2 Saico , Ball Valve Brass 3/4 , Ball Valve Ci 1-1/2 , Ball Valve Ci 2 , Braded Pipe (Kg) , Braded Pipe 1 , Braded Pipe 3/4 , Brass Elbow 1/2 , Bush 1*1/2 Cp , Bush 1*3/4 Cp , Bush 3/4*1/2 Cp , C Pvc Brass Elbow 1/2 , C Pvc Brass Elbow 3/4*1/2 , C Pvc Brass Fta 3/4*1/2 , C Pvc Brass Mta 3/4*1/2 , C Pvc Elbow 1/2 , C Pvc Elbow 3/4 , C Pvc Solution 237Ml , C Pvc Tee 1/2 , Ci Hose Nipple 1 , Ci Hose Nipple 1-1/4 , Ci Hose Nipple 3/4 , Eco Drain Pipe 110 Mm*20 Ft , Eco Drain Pipe 200 Mm*20Ft , Fix Spaner 10*11 V , Fix Spaner 12*13 V , Fix Spaner 14*15 V , Fix Spaner 16*17 V , Fix Spaner 18*19 V , Fix Spaner 24*27 V , Fix Spaner 32*36 V , Fix Spaner 41*46 V , Fix Spaner Vm-12 Set V , Fix Spaner Vm-8 Set V , Gi B/N 1*3 , Gi B/N 1*4 , Gi B/N 1*6 , Gi B/N 1/2*10 , Gi B/N 1/2*12 , Gi B/N 1/2*3 , Gi B/N 1/2*4 , Gi B/N 1/2*8 , Gi B/N 1-1/2*12 , Gi B/N 1-1/2*18 , Gi B/N 1-1/2*3 , Gi B/N 1-1/2*4 , Gi B/N 1-1/2*6 , Gi B/N 2*10 , Gi B/N 2*12 , Gi B/N 2*18 , Gi B/N 2*3 , Gi B/N 2*4 , Gi B/N 2*5 , Gi B/N 2*6 , Gi B/N 2*7 , Gi B/N 2*8 , Gi B/N 2*9 , Gi B/N 3/4*10 , Gi B/N 3/4*7 , Gi Clip 1 , Gi Clip 1/2 , Gi Clip 1-1/2 , Gi Clip 2 , Gi Clip 3/4 , Gi Clip 4 , Gi D/N 1 , Gi D/N 1/2 , Gi D/N 1-1/2 , Gi D/N 2 , Gi D/N 3/4 , Gi Elbow 1 , Gi Elbow 1/2 , Gi Elbow 1-1/2 , Gi Elbow 2 , Gi Long Bend 1 , Gi Pipe1 P.S. , Gi Pipe1/2 , Gi Pipe1-1/2 , Gi Pipe3/4 , Gi Pipe 2 , Gi Plug 1 , Gi Plug 1/2(H) , Gi Plug 1-1/2 , Gi Plug 1-1/4 , Gi Plug 2 , Gi Plug 3/4 , Gi Socket 1 , Gi Socket 1/2 , Gi Socket 1-1/2 , Gi Socket 1-1/2*1 , Gi Socket 1-1/2*1-1/4 , Gi Socket 1-1/4 , Gi Socket 2 , Gi Socket 3/4 , Gi Socket 3/4*1/2 , Gi T/N 1 H , Gi Tee 1/2 , Gi Tee 1-1/2 , Gi Tee 1-1/2*3/4 , Gi Tee 2 , Gi Tee 2*1-1/4 , Gi Tee 3/4 , Gi Union 1 , Gi Union 1-1/2 , Halwa Pipe 1 , Halwa Pipe 1/2 , Halwa Pipe 3/4 , Halwa Pipe Heavy(Kg) , Pipe Wrench 10 V , Pipe Wrench 12 V , Pipe Wrench 14 V , Pipe Wrench 18/450Mm V , Pipe Wrench 24 V , Pvc Elbow 110 Mm-4Kg Isi , Pvc Elbow 160 Mm-4Kg , Pvc Elbow 40Mm-4Kg , Pvc Elbow 50 Mm-4 Kg , Pvc Elbow 63 Mm-4Kg , Pvc Elbow 75 Mm-4Kg Isi , Pvc End Cap 20 Mm , Pvc End Cap 50 Mm , Pvc Mta 32Mm , Pvc Pipe 110 Mm , Pvc Pipe 160 Mm , Pvc Pipe 20 Mm , Pvc Pipe 25 Mm , Pvc Pipe 40 Mm , Pvc Pipe 50 Mm , Pvc Pipe 63 Mm , Pvc Pipe 75 Mm , Pvc Pipe 90 Mm , Pvc Reducer 110*75 , Pvc Reducer 25*20 , Pvc Reducer 63*40 , Pvc Reducer 75*50 , Pvc Reducer 75*63 , Pvc Socket 110 Mm , Pvc Socket 160Mm , Pvc Socket 75 Mm , Pvc Socket 90 Mm , Pvc Solvent-118Ml , Pvc Solvent-237Ml Tin , Pvc Tee 75 Mm-4Kg Isi , Pvc Tee 90 Mm-4Kg , Ring Spaner 12*13 V , Ring Spaner 14*15 V , Ring Spaner 16*17 V , Ring Spaner 18*19 V , Ring Spaner 21*23 V , Ring Spaner 24*27 V , Ring Spaner Vmr-12 V , Rachet 1/2 V , S/F Brass Elbow 1 , S/F Brass Elbow 1/2 , S/F Brass Elbow 3/4 , S/F Brass Fta 1 , S/F Brass Fta 1/2 , S/F Brass Fta 3/4 , S/F Brass Mta 1 , S/F Brass Mta 1/2 , S/F Brass Mta 1-1/4 , S/F Brass Mta 2 , S/F Brass Mta 3/4 , S/F Brass Tee 1/2 , S/F Coupler 1 , S/F Coupler 1/2 , S/F Coupler 1-1/2 , S/F Coupler 2 , S/F Coupler 3/4 , S/F Elbow 1 , S/F Elbow 1/2 , S/F Elbow 1-1/2 , S/F Elbow 2 , S/F Elbow 3/4 , S/F End Cap 1 , S/F End Cap 1/2 , S/F End Cap 1-1/4 , S/F End Cap 2 , S/F End Cap 3/4 , S/F Fta 1 , S/F Fta 1-1/4 , S/F Fta 2 , S/F Fta 3/4 , S/F Mta 1 , S/F Mta 1/2 , S/F Mta 2 , S/F Mta 3/4 , S/F Plug 1/2 , S/F R/Tee 1*1/2 , S/F Reducer 1*1/2 , S/F Reducer 1*3/4 , S/F Reducer 2*1 , S/F Reducer 3/4*1/2 , S/F Solvent 118Ml , S/F Solvent 237Ml , S/F Solvent 473Ml , S/F Solvent 50Ml , S/F Tank Connector 1 , S/F Tank Connector 1-1/2 , S/F Tee 1 , S/F Tee 1/2 , S/F Tee 1-1/4 , S/F Tee 2 , S/F Tee 3/4 , S/F Union 1 , S/F Union 1/2 , S/F Union 1-1/2 , S/F Union 3/4 , Socket Set (24 Pcs) Venus , Swr Cowel 110Mm , Swr Door Bend 110Mm , Swr Door Bend 75Mm , Swr Door Tee 110Mm , Swr Door Tee 75Mm , Swr Double Tee 75Mm , Swr Pipe 110Mm-2.5Kg Paras , Swr Pipe 110Mm-4Kg Paras , Swr Pipe 75Mm-2.5Kg Paras , Swr Pipe 75Mm-4Kg Paras , Swr Plain Bend 110Mm , Swr Plain Bend 75Mm , Swr Plain Tee 110Mm , Swr Plain Tee 75Mm , Swr Plain Y 110Mm , Swr Red Tee 110*75 Isi , Swr Shoe 110 Mm , Torch Wipro Lifelite , Upvc Ball Valve 1 , Upvc Ball Valve 1/2 , Upvc Ball Valve 1-1/2 , Upvc Ball Valve 2 , Upvc Ball Valve 3/4 , Upvc Bush 1 X 3/4 , Upvc Bush 3/4 X 1/2 , Upvc Pipe 1 , Upvc Pipe 1/2 , Upvc Pipe 1/2 Sch80 , Upvc Pipe 1-1/2 , Upvc Pipe 1-1/4 , Upvc Pipe 2 , Upvc Pipe 3/4 , V-Dite 200 Gm , V-Dite 50 Gm , V-Dite 500 Gm , Water Tank , Bosch Hammer 2Kg Mc , Bosch Hammer Demolition , Bosch Chisel Max , Bosch Chisel 18X200mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
24.
Rural Development #10252949 Price Bid
Supplying Various Types Material For Grampanchayat Kharabwadi, Tal. Khed, Dist. Pune Supplying Various Types Material For Grampanchayat Kharabwadi, Tal. Khed, Dist. Pune , 101 Lw+ Pidiproof-1Ltr , 101 Lw+ Pidiproof-20Ltr , 3.15Mm 6013 Jack , 3.15Mm 6013 Mangalam , 301 Urp Pidicrete-5Kg , Ad Spanner 10 V , Ad Spanner 10-250Mm T , Ad Spanner 12 V , Ad Spanner 15 V , Ad Spanner 8 V , Ambadi ( Jute ) , Ball Cock 1 , Ball Cock 1 / 2 , Ball Cock 3 / 4 , Ball Valve Brass 1 H , Ball Valve Brass 1 / 2 , Ball Valve Brass 1 / 2 Saico , Ball Valve Brass 3 / 4 , Ball Valve Ci 1-1 / 2 , Ball Valve Ci 2 , Braded Pipe ( Kg ) , Braded Pipe 1 , Braded Pipe 3 / 4 , Brass Elbow 1 / 2 , Bush 1*1 / 2 Cp , Bush 1*3 / 4 Cp , Bush 3 / 4*1 / 2 Cp , C Pvc Brass Elbow 1 / 2 , C Pvc Brass Elbow 3 / 4*1 / 2 , C Pvc Brass Fta 3 / 4*1 / 2 , C Pvc Brass Mta 3 / 4*1 / 2 , C Pvc Elbow 1 / 2 , C Pvc Elbow 3 / 4 , C Pvc Solution 237Ml , C Pvc Tee 1 / 2 , Ci Hose Nipple 1 , Ci Hose Nipple 1-1 / 4 , Ci Hose Nipple 3 / 4 , Eco Drain Pipe 110 Mm*20 Ft , Eco Drain Pipe 200 Mm*20Ft , Fix Spaner 10*11 V , Fix Spaner 12*13 V , Fix Spaner 14*15 V , Fix Spaner 16*17 V , Fix Spaner 18*19 V , Fix Spaner 24*27 V , Fix Spaner 32*36 V , Fix Spaner 41*46 V , Fix Spaner Vm-12 Set V , Fix Spaner Vm-8 Set V , Gi B / N 1*3 , Gi B / N 1*4 , Gi B / N 1*6 , Gi B / N 1 / 2*10 , Gi B / N 1 / 2*12 , Gi B / N 1 / 2*3 , Gi B / N 1 / 2*4 , Gi B / N 1 / 2*8 , Gi B / N 1-1 / 2*12 , Gi B / N 1-1 / 2*18 , Gi B / N 1-1 / 2*3 , Gi B / N 1-1 / 2*4 , Gi B / N 1-1 / 2*6 , Gi B / N 2*10 , Gi B / N 2*12 , Gi B / N 2*18 , Gi B / N 2*3 , Gi B / N 2*4 , Gi B / N 2*5 , Gi B / N 2*6 , Gi B / N 2*7 , Gi B / N 2*8 , Gi B / N 2*9 , Gi B / N 3 / 4*10 , Gi B / N 3 / 4*7 , Gi Clip 1 , Gi Clip 1 / 2 , Gi Clip 1-1 / 2 , Gi Clip 2 , Gi Clip 3 / 4 , Gi Clip 4 , Gi D / N 1 , Gi D / N 1 / 2 , Gi D / N 1-1 / 2 , Gi D / N 2 , Gi D / N 3 / 4 , Gi Elbow 1 , Gi Elbow 1 / 2 , Gi Elbow 1-1 / 2 , Gi Elbow 2 , Gi Long Bend 1 , Gi Pipe1 P.S. , Gi Pipe1 / 2 , Gi Pipe1-1 / 2 , Gi Pipe3 / 4 , Gi Pipe 2 , Gi Plug 1 , Gi Plug 1 / 2 ( H ) , Gi Plug 1-1 / 2 , Gi Plug 1-1 / 4 , Gi Plug 2 , Gi Plug 3 / 4 , Gi Socket 1 , Gi Socket 1 / 2 , Gi Socket 1-1 / 2 , Gi Socket 1-1 / 2*1 , Gi Socket 1-1 / 2*1-1 / 4 , Gi Socket 1-1 / 4 , Gi Socket 2 , Gi Socket 3 / 4 , Gi Socket 3 / 4*1 / 2 , Gi T / N 1 H , Gi Tee 1 / 2 , Gi Tee 1-1 / 2 , Gi Tee 1-1 / 2*3 / 4 , Gi Tee 2 , Gi Tee 2*1-1 / 4 , Gi Tee 3 / 4 , Gi Union 1 , Gi Union 1-1 / 2 , Halwa Pipe 1 , Halwa Pipe 1 / 2 , Halwa Pipe 3 / 4 , Halwa Pipe Heavy ( Kg ) , Pipe Wrench 10 V , Pipe Wrench 12 V , Pipe Wrench 14 V , Pipe Wrench 18 / 450Mm V , Pipe Wrench 24 V , Pvc Elbow 110 Mm-4Kg Isi , Pvc Elbow 160 Mm-4Kg , Pvc Elbow 40Mm-4Kg , Pvc Elbow 50 Mm-4 Kg , Pvc Elbow 63 Mm-4Kg , Pvc Elbow 75 Mm-4Kg Isi , Pvc End Cap 20 Mm , Pvc End Cap 50 Mm , Pvc Mta 32Mm , Pvc Pipe 110 Mm , Pvc Pipe 160 Mm , Pvc Pipe 20 Mm , Pvc Pipe 25 Mm , Pvc Pipe 40 Mm , Pvc Pipe 50 Mm , Pvc Pipe 63 Mm , Pvc Pipe 75 Mm , Pvc Pipe 90 Mm , Pvc Reducer 110*75 , Pvc Reducer 25*20 , Pvc Reducer 63*40 , Pvc Reducer 75*50 , Pvc Reducer 75*63 , Pvc Socket 110 Mm , Pvc Socket 160Mm , Pvc Socket 75 Mm , Pvc Socket 90 Mm , Pvc Solvent-118Ml , Pvc Solvent-237Ml Tin , Pvc Tee 75 Mm-4Kg Isi , Pvc Tee 90 Mm-4Kg , Ring Spaner 12*13 V , Ring Spaner 14*15 V , Ring Spaner 16*17 V , Ring Spaner 18*19 V , Ring Spaner 21*23 V , Ring Spaner 24*27 V , Ring Spaner Vmr-12 V , Rachet 1 / 2 V , S / F Brass Elbow 1 , S / F Brass Elbow 1 / 2 , S / F Brass Elbow 3 / 4 , S / F Brass Fta 1 , S / F Brass Fta 1 / 2 , S / F Brass Fta 3 / 4 , S / F Brass Mta 1 , S / F Brass Mta 1 / 2 , S / F Brass Mta 1-1 / 4 , S / F Brass Mta 2 , S / F Brass Mta 3 / 4 , S / F Brass Tee 1 / 2 , S / F Coupler 1 , S / F Coupler 1 / 2 , S / F Coupler 1-1 / 2 , S / F Coupler 2 , S / F Coupler 3 / 4 , S / F Elbow 1 , S / F Elbow 1 / 2 , S / F Elbow 1-1 / 2 , S / F Elbow 2 , S / F Elbow 3 / 4 , S / F End Cap 1 , S / F End Cap 1 / 2 , S / F End Cap 1-1 / 4 , S / F End Cap 2 , S / F End Cap 3 / 4 , S / F Fta 1 , S / F Fta 1-1 / 4 , S / F Fta 2 , S / F Fta 3 / 4 , S / F Mta 1 , S / F Mta 1 / 2 , S / F Mta 2 , S / F Mta 3 / 4 , S / F Plug 1 / 2 , S / F R / Tee 1*1 / 2 , S / F Reducer 1*1 / 2 , S / F Reducer 1*3 / 4 , S / F Reducer 2*1 , S / F Reducer 3 / 4*1 / 2 , S / F Solvent 118Ml , S / F Solvent 237Ml , S / F Solvent 473Ml , S / F Solvent 50Ml , S / F Tank Connector 1 , S / F Tank Connector 1-1 / 2 , S / F Tee 1 , S / F Tee 1 / 2 , S / F Tee 1-1 / 4 , S / F Tee 2 , S / F Tee 3 / 4 , S / F Union 1 , S / F Union 1 / 2 , S / F Union 1-1 / 2 , S / F Union 3 / 4 , Socket Set ( 24 Pcs ) Venus , Swr Cowel 110Mm , Swr Door Bend 110Mm , Swr Door Bend 75Mm , Swr Door Tee 110Mm , Swr Door Tee 75Mm , Swr Double Tee 75Mm , Swr Pipe 110Mm-2.5Kg Paras , Swr Pipe 110Mm-4Kg Paras , Swr Pipe 75Mm-2.5Kg Paras , Swr Pipe 75Mm-4Kg Paras , Swr Plain Bend 110Mm , Swr Plain Bend 75Mm , Swr Plain Tee 110Mm , Swr Plain Tee 75Mm , Swr Plain Y 110Mm , Swr Red Tee 110*75 Isi , Swr Shoe 110 Mm , Torch Wipro Lifelite , Upvc Ball Valve 1 , Upvc Ball Valve 1 / 2 , Upvc Ball Valve 1-1 / 2 , Upvc Ball Valve 2 , Upvc Ball Valve 3 / 4 , Upvc Bush 1 X 3 / 4 , Upvc Bush 3 / 4 X 1 / 2 , Upvc Pipe 1 , Upvc Pipe 1 / 2 , Upvc Pipe 1 / 2 Sch80 , Upvc Pipe 1-1 / 2 , Upvc Pipe 1-1 / 4 , Upvc Pipe 2 , Upvc Pipe 3 / 4 , V-Dite 200 Gm , V-Dite 50 Gm , V-Dite 500 Gm , Water Tank , Bosch Hammer 2Kg Mc , Bosch Hammer Demolition , Bosch Chisel Max , Bosch Chisel 18X200mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
25.
Defence #10169826 Price Bid
Tender For Provision Of Certain Sanction Works In The Area Of Age B/R-I Under Ge(Central) Delhi Cantt-10; 1 Taking down cement plaster of any description on brick stone or concrete walls surfaces including raking out joints hacking for keys scrubbing down with water etc incl remove alldebris in 2 KM form site complete all as specified and directed. 2 M&L for 15 mm thick rendering in cement mortaron fair faces of brick work or concrete surfaces , in cement mortar (1:4 )mixed finished even and fair etc complete all as specified and directed 3 M&L Rendering 15 mm thickin CM 1:6 on other than fair faces of brick work or concrete surfaces finished even and fair without using extra cement complete all as specified. 4 M&L for preparation of newly plastered surfaces of walls and providing and applying putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified as directed by Engr-in-charge. 5 M&L for Preparation of new surfaces (Plastered or un-plastered) of walls and applying two coats of oil bound distemper complete all as specified. 6 Dismantling water tanks and removing to store of 500 Ltr Capacity 7 Demolition of brick work built in cement orcement lime mortar of any description including quoins,arches,pillars,etc., all as directed. 8 M & L for brick work with Cement Mortar1:6 using sub class B bricks, old size , straight or curved on plan exceeding 6 m mean radius all as specified and directed. 9 Material and labour for brick work with sub class B bricks of old size, straight or curved on plan exc 6m mean radius in half brick walls, in CM 1:4 complete all as specified and directed. 10 M &L Brick work with sub classB bricks straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4, complete, all as specified and as directed. 11 Dismantling of wall and ceiling/cup board boarding fibre pulp AC boards etc any thickness including cover fillets removing the wiring 12 M and L Providing & Fixing False ceiling with semi perforated 12mm thcik micro tegular edged at all heights with GRG (Glass Fibre reinforced Gypsum) false ceiling tiles for temp buildings/PMT Bldgsof size 595x595mm of approved texture, design and pattern having moisture content less than 2%,humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part-4)-1970 and light Code Description unit rate No 429 SUB HEAD :26.0 NEW TECHNOLOGIES AND MATERIAL reflectance of 85% minimum to be laid in true horizoatal level suspended on interlocking metel T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanised @ 120 grams oer sqm including both sides) comprising of main-T runners of size 15x32mm of length 3000mm, vross-T of size 15x32nn of lenght 1200mm amd secondry itermediate cross-T of size 15x32 of lenght 600mm to form grid module of size 600x600mm, suspended from ceiling using galvanised mild steel items (galvanising @ 80 grams per sqm) ie. 50mm long, 8mm outer diameter M-6 dash fasteners or 3 to 4 mm GI hanging wire for temp Bldg length/ht as per site req ,6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm.Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000mm to be fixed on perimeter wall/partition with the help of plastic rawl pluhs at 450mm center to center and 40mm long dry wall screws. The work shall be carried out as per specification, drawing and as per direction of the Engineer-incharge. 13 Taking down chowkhat or frame not exceeding 1.5 sqm each with shutter (without taking off shutter from the frame) 14 Taking down chowkhat or frame exceeding 1.5 Sqm each and not exceeding 4 Sqm each sqm each with shutter (without taking off shutter from the frame) 15 S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of EngineerIn- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)complete all as specified and directed. 16 S&F glazed Skelton shutter IInd class hard wood 30 mm thick rebated and prepared to received glass, gauge etc divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers fitted with mitred beads for securing glass etc size of members of shutter as specified in SSR Part-I section 8,clause 8.24(a) etc.complete all as specified and directed. 17 S&F Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified,size 105x60mm all as specified 18 S&F Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete as specified,size 165x60mm (double frame) 19 Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors,windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size,including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle,Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. 20 Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. 21 S & F mild steel framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders framed balusters, walk ways, railings, framework of water tanks and similar work including aldrop and hinges holdfast etc conforming to Fe 290. Gde-E-165. 22 S&F MSbutt hinges medium weight 100 mm size fixed with MS screws. 23 S&F aluminium anodised barrel tower bolt extruded section 150 mm long and fixed with MS screws. 24 S&F 150 mm extruded aluminium alloy handle anodised fabricated type and fixed with mS screws. 25 S&F 300 mm extruded section aluminium alloy anodised, sliding door bolt with hasp and staple and fixing clip of sheet and fixing bolt and nut. 26 S&F for 300 mm MS ordinary rat tail rod pattern spring including roller and roller plate complete fixed on wooden frame or on wall with wooden plugs and set in cement mortar all as directed. 27 M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified 28 M&L preparation of Old or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified 29 M & L for preparation of Old or previously untreated wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified 30 S & F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm complete all as specified and directed. 31 S&F in repair stainless steel sink with drainage board made out of 1mm thick sheet for kitchen with plug, washers, waste pipe, waste coupling incl fixing cast iron cantilever bracket connecting union over all size 915x460mm with bowl size410x330x160mm complete all as specified and directed by Engineer-in-Charge. 32 Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 15mm 33 All as per item No. 32above but 20 mm bore . 34 All as per item No. 32above but 40 mm bore . 35 Supplying and laying 15 mm dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified complete all as directed 36 All as per item No. 35 above but 20 mm dia 37 All as per item No. 35 above but 40 mm dia 38 S & F Floor door stopper 150mm size of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor all as directed. 39 Supply and fix vitreous China wash hand basin (pedestal)white of size 550X400mm excluding taps, waste chain and plug and porcelain stopper and waste pipe & waste coupling including all necessary fitting and fixtures complete all as specified 40 S & F in repairs 15 mm dia 600mm long PVC connectionswith brass check nut complete Make Polytuff/symet or equivalent 41 S&F in repairs bib taps 15 mm bore chromium plated brass, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule Make-Jaquar/marc/Kohlar, complete all as specified 42 S&Fin repairs angle valve, fancy type, chromium plated brass, 15mm, complete all as directed. 43 S&F in repairs looking mirror of size 600mmx450mmx5.5mm thick with aluminium frame selected quality mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers. 44 Demolition of stone slab and tiles of any description or thickness in floor apron etc complete all as specified and directed. 45 S & F for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match to 10mm thick (1:4) CM Screed bed 46 All as per item no. 45 except on vertical surfaces as in skirting etc over 10mm thick backing coat in CM 1:4, set and jointed in white cement with pigment to match all as specified and directed. 47 M&L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement mortar (1:6) complete all as specified and as directed. 48 M&L for 18-20 mm Granite (any type) work (table rubbed and polished) in steps,jambs,pillars window-cill,cooking platforms and incl 15mm thick screed bed in CM 1:6 using marble dust with admixturein CM (1:4) with pointing and white cement (1:2)of pigment to match with shade of granite all as spd. 49 M&L for machine cut polished Machine cut Kota stone 20-25mm thick as in floor, tread, riser, pillar fixed with neat cement slurry over backing coat of 20mm thick in CM (1:4) including rubbing and polishing complete all as specified. 50 Dismentling asbestos cement corrugated orsemi corrugated sheets in roof fixed with L hook or cranked bolt 51 S & F Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified 52 S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified 53 Demolition of cement concrete (un-reinforced) as path, paving and any position and any thicknesscomplete all as specified and directed. 54 M & L for 75 mm thick cement concrete 1:3:6type C2(using 40mm graded stone aggregate) as in plinth protection laid in bays & surfaces finished even and smooth , complete all as specified. 55 M & L for 40 mm thick cement concrete 1:2:4type B1(using 12.5mm graded stone aggregate) as in floor & surfaces finished even and fairusing extra cement, complete all as specified. 56 Demolition of reinforced cement concrete in any position all as specified and as directed by Engineer -in-Charge. 57 Material and labour for reinforced cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in roof slabs, slab supported on walls, cooking platform, beams and columns, in floors roofs, landings, balconies, canopies and in chajjas, parapet, shelves and the like complete all as specified and directed. 58 Use and waste of form work to soffits of suspended slabs such as roof slab, Chajja, platforms and landings etc not exc 200mm thick (horizontal or sloping) for fair finished surfaces of concrete complete all as specified and directed. 59 S&F TMTsteel bars of 10 mm dia and over, cut to length bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to. complete all as specified and as directed. 60 M&L for rotational moulded polyethylene water storage tanks white colour500 lts capacity, triple layered (cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia PTMT float valve, lid tank cover for polyethylene and polyethylene balldescription including fitting and fixtures complete all as specified. (ISI Marked) 61 S&F 20 mm bore tank nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms) complete all as specified and directed 62 S&F 25 mm bore tank nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms) complete all as specified and directed 63 Demolition and breaking up rain water pipes (CI,AC,PVC etc) set in any cement mortar of any diameter incl bends. 64 S/F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, soil, waste, vent pipe in any length with or without ears ,110mm bore complete. 65 S/F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, soil, waste, vent pipe in any length with or without ears 75 mm bore complete. 66 Supply only for broken brick coarse aggregate n.exc 40mm deposited, spread and levelled in layers watered and rammed to a true surfaces complete all as specified. 67 S&F rolled sections as in main and cross beams, hip and jack rafters; purlins , pillars, trusses , water tank stage , framed guard bars, barred iron doors, ladders, frame balusters, walk ways, railing and similar work where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed 68 Disconnecting existing 500/1000 ltr tanks, setting a side (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including all necessary fitting and fixtures complete all as specified and directed. 69 M&l for Cleaning the entire area first by broom, chipping unwanted area using chisel and hammer, cleaning/ smoothening by wire brush, washing the entire surface using waterjet and finally by broom and airjet and applying 15mm average thickness plasetring in single layer and finishing with trowel with a bond coat: SBR polymer (@ 10% of cement weight and applying one layer of cement and Nushar make CCP mix in the ratio Cement:CCP:Water::1:1:0.2 and mixing it thoroughly using electric mixer coating to be done atleast 1’ longitudinally to secure edges and Filling all visible cracks using Nushar crack pack master/ Nushar make Cladofix. Laying 66 gsm non woven fiber along with 2nd and 3rd coat of CCP mix and cement mixture as in step 2 . Filling overlapping joints using Nushar make Master adhesive. Apply 1st coat of Nushar make Polymembrane coat using brush across the area. After curing of above layer apply second coat of Polymembrane coat. Apply 1st coat of Nushar make Nano top coat. Ponding test to be done by filling atleast ½” water in the entire area. Removing the water after the test is successfully completed. Apply 2nd layer of Nushar make Nano top coat to finish the work all as spd and directed by Engr -in-charge. 70 S & F for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile not exceeding 0.18 sqm as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed. 71 M&L for cement concrete 1:2:4 type B1 (using 12.5mm graded stone aggregate) on roof paddingsurface finished even and smooth without using extra cement complete all as spd & directed. 72 Surface excavation n. exc (not exceeding) 30cm deep and averaging 15cm deep and geeting out hard/dence soil 73 Excavation in trenches, n exc 1.50 m wide and n exc 1.50 m in depth; for foundation, etc. or for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc, n exc 10 sqm on plan and n exc 1.50m in depth and getting out hard/ dense soil. 74 PCC (1:4:8) type D-2 using 40mm graded stone aggregate in fdn, filling/mass concrete 75 M&L RCC (NOMINAL MIX) M-20 (Type B1 1:2:4 Using 20mm graded stone aggregate) as in foundation including raft footings, foundation beams, plinth beam, basis for columns, pillars piers, post and struts etc, complete all as specified and as directed.( as per drawing attached) 76 M&L RCC (NOMINAL MIX) M-20 (Type B1 1:2:4 Using 20mm graded stone aggregate) as in columns, pillars piers, posts and struts etc.complete all as specified and as directed.(as per drawing attached) 77 M&L RCC(NOMINAL MIX) M-20 (Type B1 1:2:4 Using 20mm graded stone aggregate)as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies,canopies, deck slabs and in shelves and the like.(as per drawing attached) 78 M&L forMild steel TMT bars 10mm dia and over , cut to length, bent to shape required, including cranking , bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed 79 M&L forMild steel TMT bars 6mm to 8mm dia , cut to length, bent to shape required, including cranking , bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed 80 M&L Formwork to sides of concrete foundations, footing, basis of coloumns , raft & raft beams,, sides & soffits of foundation & plinth beams and similar work vertical or to batter, fair finished surfaces of concrete complete all as specified and as directed 81 M&L Formwork to Formwork to sides of pillars, posts, struts, piers, columns and stanchions fair finished surfaces of concrete complete all as specified and as directed 82 M&L for Formwork to soffits of Curved suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) 83 Rendering 10mm thick in CM 1:4 on fair faces of concrete surfaces finished even and fair with out using extra cement all as specified. 84 M & L for mild steel framed work framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing Fe 410-W (GdeE- 250) qualityA complete all as specified. 85 S & F Joist, channel, angle, or tee sections,fixed independently, without connecting plates, etc. in posts and struts including cutting tops to shape as directed Fe-290(Gde E-165) 86 M&L for two coat cement base paint over a coat of alkali resist priming paint including preparation of wall surface complete all as directed by Engineer-in-Charge. 87 Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint( texture paint with design) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces all as specified( Colour and disigen will approved by User) 88 M&L for 50mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregate in paving surfaces including finishing surface even & smooth 89 M&L for 100mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate in paving surfaces including finishing surface even & smooth 90 M&L Rendering 10 mm thickin CM 1:6 on fair faces of brick work or concrete surfaces finished even and fair without using extra cement complete all as specified. 91 S&F Factory Made 18mm thick 100% Solid WPC ( Wood polymer Composite ) Laminated Board of required size comprising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cbmhaving good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compissive of 50 N/mm2 , Modulus of elasticity 850N/mm2and esistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter and fixinng stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws. All as per direction of Engineer -In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company : For WC/Bathroom/Toilet/Kitchen and Cabinets. 92 M & L for 2nd Second class hard-wood in scantlings clean swan timber an fixed all as specified & directed. 93 Excavation in post holes (or similar holes) in any type of soil, each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm, watering and removing surplus spoil to distance not exceeding 50 mtr and making good surface complete all as specified and directed by Engineer-in-Charge 94 M&L for 50mm thick PCC 1:3:6 type C2 using 20mm graded stone agg as in sub base complete all as specified.. 95 M&L for 22 to 25mm chequered ultra tiles over 15 mm thick screed bed in cm 1:6 and jointed and pointed in white cement mixed with pigment to match the shade of tiles of flooring all as directed. 96 S&Ffor fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steadythe frame and fixing with ancher bolts all as specified and as directed. 97 S & F 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conformingto IS: 14856, including fixing to frames. 98 S&F Modular Cabinet Kitchen accessoriesof Stainless Steelgrade-304,6mm size rod thicknessincluding :-(i) Perforated Cutlery basket, (ii) Grain trolley, (iii) Thali basket,(iv) Cup & saucer basket, (v) Glass basket,(vi) Plate basket, (vii) Premium magic corner(viii) Oil Pull out Tray ( Triple basket layer) , (ix) Dust bin, (x) Cleaning kit rack of size as per site requirement all spd and directed by Engr in charge 99 S & F50 mm dia Galvanised Iron steel tubing, medium grade as in spout in short length, complete all asspecified. 100 S&F in Soft closing ball bearing telescopic channel of size 22 inch long fixed with screws in cupboards incl all fittings complete all as spd and directed by Engr in charge.Note : Runner/ Channel should be SS 304 grade and load capacity should not be less than 45 kgs 101 M & L for Non skid 600x600x8 to 8-10mm thick coloured ceramic tiles as in floor over hacking surface of existing floor on 15mm thick screed bed in CM 1:6 including pointing in coloured cement to match the shade of tilesincluding cutting of existing door shutter at required height. complete all asspecified directed by Engr-in-Charge, and approved by GE Make-kajaria/Johnson,Somany 102 S&F 15mm GI tubes, medicum grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors. 103 Ditto but 20 mm bore. 104 S&F PVC valve less, syphonic action type low level flushing cistern of capacity 10 Ltrs with inlet, ball valve, float and handle and fixed to IWC on existing brackets, fixed in repairs. 105 S&F in repair bathroom mirror 400x600mm decorative mirror selected qualtiy glass, with PVC frame complete all as specified and directed. 106 S&F chlorium platedshower roses with or without swivel join ts 100mm size incl fixingto steel pipe in repairs 107 S&F in repair vitreous china Pedastal, for above mentioned item no. 78 complete all as specified and directed. 108 S & F in repair toilet paper holder with flat recessed type stainless steel complete all as specified and directed. 109 S & F in repairs Chromium plated health faucet (hand spray) with 1mtr long PVC flexiable pipe 15mm boreand fixed to in position etc complete all as specified and directed. 110 M&L Glazed ceramic colouredtiles (600X300mm) x 7mm thick on vertical surfaces etc,set and jointed in neatcement slurry and pointed in white cement to match the shade of tile over 10mm thick rendering of in cement mortar 1:4. 111 S&F solid PVC door Prelam frame of sixe 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening as per specification and drawing. 112 S&F factory made soilid panel PVC Door shutter 30mm thick (Stype) both side prelam clouor consisting of frame made out MS frame shall be covered with heat moulded plain coloured PVC C channel having PVC sheet stripof 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail, & bottom rail; Panneling of both side prelam clouor PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification and drawing. 113 M&L formachine pressed precast concrete interlocking paver block with gray cement and no pigment, any shape and size confirming to IS- 15658 -2006 of 80mm thickness, M-40 Gde,Over and including 20mm thick layer of sand completeall as specified and directed. 114 S&F150mm long extruded stainless steel handle fabricated type 115 S&F 100 mm long(size)butt hinges medium weight, cold rolled,mild steel, complete all as specified(Fixing included in item 43 here-in-before). 116 S&F 4.8 mm thick sheet frosted glass, ordinary quality and glazing in Aluminium door with solar control files 50 micronin squares exc 0.5 Sqmeach pane.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
26.
Defence #9982106 Technical Bid
Tender for Demolition Of Cement Concrete (Un-Reinforced) In Ground Floors And Pavings N Exc 15 Cm Thickness (Below Or Above Ground Level Complete. , Excavation In Trenches N. Exc 1.5 M Wide And N.Exc 1.5 M Deep For Foundation And Getting Out In Soft/Loose Soil. , Excavation In Trenches Not Exceeding 1.5M Wide And Not Exceeding 1.5M In Depth; For Foundation/ And Getting Out In Hard/Dense Soil Complete All As Specified And Directed. , Extra For Forming Fair Finishing Drain Or Channels 30 Cm Inner Girth In Cement Concrete Using Extra Cement Including Forms, Moulds Stopped Ends Etc.Complete All As Specified And Directed. , Extra Over Stone Walling For Hammer Dressing With Maximum Depression From Straight Edge Held Against The Dressed Surface N Exc 40 Mm Granite Or Trap Stone To Face Beds And Joints As Specified Of Random Rubble Walling Uncoursed Or Brought Upto Courses Complete All Specified And Directed. , M & L For Plain Cement Concrete (1:2:4) Type B-1(20 Mm Graded Stone Aggregate) Mass Concrete As In Drain Wall Etc Complete. , M&L For 75 Mm Thick Plain Cement Concrete Type C-2, 1:3:6 (40Mm Graded Aggregate) As In Sub-Base, Floors And Pavings Etc Complete All As Secified And Directed. , M&L For Cement Concrete Type D-2, 1:4:8 In Cement Concrete (40 Mm Graded Aggregate ) In Foundations, Filling And Mass Concrete Complete All As Specified And Directed , M&L For Hard Core, (Broken Srone Or Boulders) Broken To Gauge Exc 63 Mm And N Exc 100Mm Complete All As Specified And Directed. , M&L For Joint Free Non - Skid Ceramic Coured Tiles 7 To 8 Mm Thick Area Of Each Tile Exceeding0.18 Sqm But N.Exc 0.38 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement Complete. , M&L For Keyed Pointing To Random Rubble Masonry Or Brought Upto Course In Cement Mortar 1:4 Complete All Specified And Directed. , M&L For Plain Cement Concrete 1:3:6 Type C-1(20 Mm Graded Aggregate) Precast Cement Concrete Block Masonry With Solid Blocks Exc 10 Cm In Width And Setting In Cm 1:6 Etc Complete All As Specified And Directed , M&L For Plain Cement Concrete 100Mm Thick, Type D-2, 1:4:8 (Using 40Mm Graded Stone Agg) In Sub-Floors, Sub-Base, Floors And Pavings Etc. Complete All As Specified And Directed , M&L For Plain Cement Concrete 40Mm Thick, Type B-1, 1:2:4 (Using 20Mm Graded Stone Agg) In Floors And Pavings Etc Finished Ecen And Smooth With Using Extra Cement Complete All As Specified And Directed By Engr In Charge. , M&L For Plain Cement Concrete 75Mm Thick Type C-2, 1:3:6, (40Mm Graded Stone Aggregate) As In Plinth Protection, Finishing Cement Concrete Surfaces Even And Smooth Without Using Extra Cement. , M&L For Plate Girder Or Single Stanchions, Built Up Of One Beam Or Channel Section With Flange Plates, Caps, Bases. Splices, Angle Brackets, Cleats And Other Connections Conformimg To Fe -290(Gde E -165) Complete All As Specified And Directed , M&L For Precast Plain Cement Concrete Bonders (For Stone Walling) Type B-1, 1:2:4 (20Mm Graded Stone Agg) In Cm 1:6 As In Bond Stone Complete All As Specified And Directed , M&L For Prepairing Surfaces Plastered Or Unplastered Newly Surfaces With Two Coats Of Cement Base Paint Over Primimg Coat Complete All As Specified And Directed By Engr In Charge , M&L For Preparation Of Newly Plastered Wall Surfaces And Applying Two Coats Of Oil Bound Distemper Over A Coat Of Primer Complete All As Specified And Directed By Engr In Charge , M&L For Preparation Of Newly Steel Surface Of Any Description, Over 10Cm In Width Or Girth,Not Otherwise Described With Two Coat Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Complete All As Specified And Directed , M&L For Screed Bed Or Bedding Layer Of 15Mm Thick In Cement Mortar 1:4 For Laying Floor Tiles Etc All As Specified. , M&L For Walling Of Random Rubble Uncoursed, Well Bonded,Bedded And Solidly Hearted Built In Cm 1:6 Complete All As Pecified And Directed , M&L Forming 12Mm Thick Expansion Joints Filled With Pre-Formed Bituminous Filler And Top 30Mm Primed And Sealed With Sealing Compound, Grade ‘A For 75 Mm Thick Concrete Slab. , M&L Plain Cement Concrete 1:2:4 Type B-1 Using 20Mm Graded Stone Aggregate As In Coping Complete All As Specified And Directed , M&L Rendering 10 Mm Thick In Cm 1:4 On Concrete Outer Surfaces Finished Even And Smooth Without Using Extra Cement . , M&L Rendering 10Mm Thick In Cm 1:6 On Concrete Inner Surfaces Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed , M&L Rendering Mixed With Liquid Wpc By 0.4% Of Cement Weight 15Mm Thick In Cm 1:4 On Concrete Outer Surfaces Finished Even And Smooth Without Using Extra Cement .Complete All As Specified And Directed , Removing Excavated Material Not Exc 50 Mtr Depositing Where Directed At A Level Not Exc 1.5 Mtr Above The Starting Point Complete All As Specified And Directed. , Returning Filling In Incl Spreading,Levelling, Watering And Well Ramming In Layers N.Exc 25Cm. , Rough Excavation N Exc.1.5M Deep And Gatting Out In Hard/Dense Soil. Complete All As Specified And Directed. , S & F Steel Work In Tubular Trusses Including Special Shaped Washer Etc. Complete Using Erw Or Induction Butt Welded Tubes Conforming To I. S.1161- 1979 Grade St.-240 Complete As Specified. , S&F Of 110Mm Dia Pvc (Swr) Pipes Single Socketed In Any Length With Rubber Ring Joints Fixed To Walls. , S&F Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/Cladding To Wall, Ridge , Gutter, Gable Flashing, Corner Flashing Etc, Fixed With Self Tapping Screws As Specified And Directed. , S&F Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Plain Steel Sheet 0.50Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/Cladding To Wall, Ridge , Gutter, Gable Flashing, Corner Flashing Etc, Fixed With Self Tapping Screws As Specified And Directed. , Supply Only Of Liquid Water Proofing Compound For Exteenal Plastering Complete All As Specified And Directed By Engr In Charge , Surface Excavation N.Exc (Not Exceeding) 30 Cm Deep And Averaging 15Cmdeep And Getting Out In Hard/Dense Soil. , Use And Waste Flat Form Work To Vertical Faces Of Drain/Retaining Wall And Similar Work . , M/L For Point Wiring In Casing Caping With 1.5Sq Mm Frlsh Pvc Insulated Unsheathed Single Core Multithreaded Copper Conductor Cable 1100 Volts Grade Incl 1.5 Sq Mm Pvc Insulated Unsheathed Copper Conductor Cable As Earth Continuity Conductor Drown Through In And Incl Casing Caping With Its Accessories Pressed Steel Terminal Box Incl 3Mm Thick Isi Marked Laminated Sheet Cover For Fixing Switches/Socket/Regulators Etc For The Following:- One Light/Fan Point Controlled By One No Piano Type Switch 5 Amps Single Pole One Way , One Socket Outlet 5/3 Pin 6 Amps Controlled By One Switch On Same Board. , One Socket Outlet 5/3 Pin 6 Amps Controlled By One Switch On Independent Board. , All As Per Item No 1 Above But One 3 Pin Socket Out Let 15/16 Amps With Three Nos Single Core Unsheathed Pvc Insulated Cable Multistranded Copper Conductor Of Size 2.5 Sq Mm For Phase, Neutral & Earth Continuity Conductor. , S&F Switch Piano Flush Button Single Pole One Way 5/6 Amp. , S&F Switch Piano Flush Button Single Pole One Way 15/16 Amp. , S&F Socket Outlet 2 In 1, 3 Pin & 2 Pin, 5/6 Amp, 240 Volt. , S&F Socket Outlet 2 In 1 , 3 Pin & 2 Pin, 5/6 annual periodical maintenance And 15/16 Amp, 240 Volt. , S&F Ceiling Rose Surface Bakelite 65Mmx50mm 100Watt Three Terminal. , S&F Sheet Metal Enclosure Double Door For Mcb Db Single Pole And Neutral 8 Way With 200 Amps Rated Bus Bar 240 Volts Double Door (Metallic) Type. , S&F Mcb Spn 40 Amps 240 Volts C Series, 10 Ka, 50 Hz. Make:- As Approved Make Of Db , S&F Mcb Sp 5 To 32 Amps 240 Volts C Series, 10 Ka, 50 Hz Including Connection In The Db And Testing/Commissioning. Make:- As Approved Make Of Db , Supply And Fixing Led Lights Fitting 1X 18W, 4 Feet, 220V,Ac Decorative Box Type With Driver, Holder Including Led Light Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose Complete. , Supply And Fixing Led Light Fitting 35 Watt 230 V Ac Outdoor Type With High Pressure Die Cast Aluminum Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Including Thermal Management In Multiple Optics Complete With Ip 65/66 Protection Complete. , S&F Of 1100 Volts Grade Heavy Duty Isi Marked Cable Pvc Insulated Multi Stranded Aluminium Conductor One Twin Core Cable Flat Or Circular Of Size 10 Sqmm Served With Inner Sheathing Of Pvc Sheathed In Service Connections, Of Size 10 Sqmm 2 Core. , Material And Labour For Earthing Complete With Galvanized Steel Earth Plate Electrode 600 X 600 X 6 Mm Thick Buried Directly In Ground( Earth Pit Not Less Than 2.25 Meter Deep Below Ground Level) With Top Edge Of Plate Not Less Than 1.5 Meter Below Normal Ground Level, Connected To Galvanised Earth Lead Wire 4.0Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanized Iron Or Steel, All As Shown In Electrical Plate No 3 Of Ssr Pt I Including Necessary Excavation And Earth Work Plain Cement Concrete (1:3:6) Type C-1 With 50 Mm Thick Pre Cast Reinforced Cement Concrete ( 1:2:4) Type B-1 Cover Slab Framed With 50X30x4 Mm Ms Angle (Reinforced With 6 Mm Dia Deformed Bar @ 15 Cm C/C Both Ways And Suitable Handle Of 10 Mm Dia Round Bar) Including Providing Charcoal Or Coke And Magnesium Sulphate In Alternate Layers Of 15 Cm Compacted Thickness All Around The Earth Electrode, With Funnel And 20 Mm Bore Galvanized Iron Watering Pipe (Medium Grade) Wire Mesh, Copper Lugs, Complete In All Respect., Gi Earth Wire Protected By 40 Mm Bore (Light Grade) Galvanized Iron Pipe And Other End Connected To The Earth Bar (Test Point) Made Of Ms Flat (400X32x6 Mm) Bend In ‘D Shape And Fixed To Wall By Means Of Fast Nut Or Bolt Grouted In To Wall At 1 Mtr From Plinth Height. 4Sqmm Pvc Insulated (Colour Green) Copper Conductor Single Run As Earth Continuity Conductor Along With 15 Mm Pvc Conduit Grouted In Wall Or Fixed On Wall Surface To Be Continued Up To Main Switch Board And Fix With Common Earth Dolly As Directed By Eic . Disposal Of Soil To A Distance Not Exceeding 50 Mtr And Necessary Testing On Completion Complete All As Specified And As Directed. , M & L For Cable Route Marker With Route Indication On Cast Iron Disc Of 100Mm Dia And 10Mm Thick, Marked / Written For Lt Cable 1100 Volts Embosed Including Indicating Direction Fixed / Bolted To 40Mmx40mmx6mm Thick Ms Angle Iron Support Of 0.5M Long Embedded Upto 200Mm Depth In Concrete Block Of Size 200Mm X 200Mm X 500Mm Of Mix Plain Cement Concrete 1:3:6, Type C-1 Including Painting With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer To Exposed Steel Surfaces Complete All As Specified And Directed. , M & L High Galvanized Mast Light 15 Mtr Height Suitable For 8 Lanterns Symmetrically Fitted Along With Their Control Gear And Having Two Point Suspension System With Stainless Steel Wire Rope Of 6 Mm Dia 97/19 Guage And Double Drum Winch With Luminaire Mounting Arm, Pully Assembly, Aviation Obstruction Light, Lightning Arrester Spike Including Earth Work And Reinforced Cement Concrete Foundation. , Supply And Fixing Led Flood Light 100 Watt 230 V Ac Outdoor Type With Thermal Management In Multiple Optics And Equipped With Ip66 Protection, With Impact And Corrosion Resistant Complete With Driver And Lamp , M&L Xlpe Insulated, Armoured Heavy Duty Electric Cable With Aluminium Conductor, 1100 Volts Grade, Cross-Sectional Area 10 Sqmm 4.0 Core , S&F High Density Polyethylene Pipes (Hdpe) Of Pressure Rating 6 Kgf/Cm2 Laid In Trenches Of Size 50 Mm Bore
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 8
Arunachal Pradesh View Result →
27.
Public Administrative Department #9955726 AOC
Tender For Supplying Motor Pump Material For Financial Year 2025-26 Under Municipal Council Chhatarpur- 1 1 HP Submersible Pump Sets SP/TP Kirlosker/Taxmo/KSB/CG 2 1.5 HP Submersible Pump Sets SP/TP Kirlosker/Taxmo/KSB/CG 3 2 HP Submersible Pump Sets SP/TP Kirlosker/Taxmo/KSB/CG 4 3 HP Submersible Pump Sets SP/TP Kirlosker/Taxmo/KSB/CG 5 5 HP Submersible Pump Sets SP/TP Kirlosker/Taxmo/KSB/CG 6 7.5 HP Submersible Pump Sets SP/TP Kirlosker/Taxmo/KSB/CG 7 1 HP Open well Submersible Pump Sets SP/TP Kirlosker/Taxmo/KSB/CG 8 2 HP Open well Submersible Pump Sets SP/TPKirlosker/Taxmo/KSB/CG 9 3 HP Open well Submersible Pump Sets SP/TP Kirlosker/Taxmo/KSB/CG 10 5 HP Open well Submersible Pump Sets SP/TP Kirlosker/Taxmo/KSB/CG 11 7.5 HP Open well Submersible Pump Sets SP/TP Kirlosker/Taxmo/KSB/CG 12 1 HP Monoblock Pump Sets SP/TP Kirlosker/Taxmo/KSB/CG 13 2 HP Monoblock Pump Sets SP/TP Kirlosker/Taxmo/KSB/CG 14 3 HP Monoblock Pump Sets SP/TP Kirlosker/Taxmo/KSB/CG 15 5 HP Monoblock Pump Sets SP/TP Kirlosker/Taxmo/KSB/CG 16 10 HP Monoblock Pump Sets SP/TP Kirlosker/Taxmo/KSB/CG 17 1 HP Starter DOL/SD (L&T / BCH / Jyoti / Crompton) 18 2 HP Starter DOL/SD (L&T / BCH / Jyoti / Crompton) 19 3 HP Starter DOL/SD (L&T / BCH / Jyoti / Crompton) 20 5 HP Starter DOL/SD (L&T / BCH / Jyoti / Crompton) 21 7.5 HP Starter DOL/SD (L&T / BCH / Jyoti / Crompton) 22 10 HP Starter DOL/SD (L&T / BCH / Jyoti / Crompton) 23 10 HP Starter Star Delta TP (L&T / BCH / Jyoti / Crompton) 24 1 HP Pannel Board SP CSCR (L&T / BCH / Jyoti / Crompton) 25 1.5 HP Pannel Board SP CSCR (L&T / BCH / Jyoti / Crompton) 26 2 HP Pannel Board SP CSCR (L&T / BCH / Jyoti / Crompton) 27 3 HP Pannel Board TP DOL With Auto Switch (L&T/BCH/Jyoti /Crompton) 28 5 HP Pannel Board TP DOL With Auto Switch (L&T/BCH/Jyoti/Crompton) 29 7.5 HP PannelTP DOL With Auto Switch (L&T/BCH /Jyoti/ Crompton) 30 10 HP Pannel Board TP DOL With Auto Switch (L&T/BCH/Jyoti/Crompton) 31 16 AMP. Main Switch RKLite/Havells/Samsonite/CG/sentell 32 32 AMP. Main Switch RKLite/Havells/Samsonite/CG/sentell 33 63 AMP. Main Switch RKLite/Havells/Samsonite/CG/sentell 34 100 AMP. Main Switch RKLite/Havells/Samsonite/CG/sentell 35 1.5 mm Cable Wire ISI 3 Core Copper Kirloskar/Finolex/Pollycab/RR 36 2.5 mm Cable Wire ISI 3 Core Copper Kirloskar/Finolex/Pollycab/RR 37 4 mm Cable Wire ISI 3 Core Copper Kirloskar/Finolex/Pollycab/RR 38 6 mm Cable Wire ISI 3 Core Copper Kirloskar/Finolex/Pollycab/RR 39 4inch CI Footvalve Kirloskar 40 3inch CI Footvalve Kirloskar 41 2.5inch CI Footvalve Kirloskar 42 2inch CI Footvalve Kirloskar 43 1inch CI Footvalve Kirloskar 44 50 mm. Rubber gas kit 45 80 mm. Rubber gas kit 46 50 mm CI NRV Heavy Flange type Kirloskar/SIR/Joloto 47 80 mm CI NRV Heavy Flange type Kirloskar/SIR/Joloto 48 100 mm CI NRV Heavy Flange type Kirloskar/SIR/Joloto 49 50 mm MS Clamps 50 80 mm MS Clamps 51 2inch suction pipe dutrone kanaflex /kasta 52 2.5inchsuction pipe dutrone kanaflex /kasta 53 3inchsuction pipe dutrone kanaflex /kasta 54 4inchsuction pipe dutrone kanaflex /kasta 55 Water tank (sintex) 0 to 2000 ltr. 56 Water tank (sintex)2001 to 10000 ltr. 57 Water tank (sintex) 10000 to 25000 ltr. 58 Chaknat Heavy 2.5x2 59 Chaknat Heavy 3x2.5 60 Chaknat Heavy 3x2 61 Chaknat Heavy 4x3 62 HDPE Nipple 1 inch 63 HDPE Nipple 1.25 inch 64 HDPE Nipple 1.5 inch 65 HDPE Nipple 2 inch 66 HDPE Nipple 2.5 inch 67 HDPE Nipple 3 inch 68 HDPE Nipple 4 inch 69 0.5inch GM Gate valve Brass Heavy 70 1inch GM Gate valve Brass Heavy 71 1.5inch GM Gate valve Brass Heavy 72 2inch GM Gate valve Brass Heavy 73 2.5inch GM Gate valve Brass Heavy 74 0.5inch GI Pipe ISI Medium Tata/Jindal/TT Swastik 75 1inch GI Pipe ISI Medium Tata/Jindal/TT Swastik 76 1.25inch GI Pipe ISI Medium Tata/Jindal/TT Swastik 77 1.5inch GI Pipe ISI Medium Tata/Jindal/TT Swastik 78 2inch GI Pipe ISI Medium Tata/Jindal/TT Swastik 79 1inch HDPE Pipe ISI 6 Kg/cm2 Kasta/Finolex/Jain/Kisan 80 1.25inch HDPE Pipe ISI 6 Kg/cm2 Kasta/Finolex/Jain/Kisan 81 1.5inch HDPE Pipe ISI 6 Kg/cm2 Kasta/Finolex/Jain/Kisan 82 2inch HDPE Pipe ISI 6 Kg/cm2 Kasta/Finolex/Jain/Kisan 83 2.5inch HDPE Pipe ISI 6 Kg/cm2 Kasta/Finolex/Jain/Kisan 84 Rubber Sheet 85 Crimping tools 86 Demolition electric Hammar (Alfa,Boch &Htaichi make) 87 Hammer 5.0 kg. 88 Hammer 2.0 kg. 89 Hammer 0.5 kg. 90 Chiesel taparia 91 Adjustable screw wrentch tapariya 92 Grinding wheel 4inch 93 Messuring Tap steel 20 mts. 94 Messuring Tap pvc 30 mts. 95 Cut of wheel 4inch bosch 96 tools kit bosch taparia 350 items complete 97 Tank stopper brass 98 M-Seal 100gm 99 Torch Rechargeable 100 Nut Bolts 101 tochan wireRope 102 CI Pipe ISI Medium Tata/Jindal/TT Swastik (All Size) 103 Hodge Clamp 104 Cotton Tape 105 Nut Bolt 106 Solvent 107 UNION0.5 inch 108 UNION 1 inch 109 UNION 1.25 inch 110 UNION 1.5 inch 111 UNION 2 inch 112 UNION 2.5 inch 113 UNION 3 inch 114 UNION 4 inch 115 TEE 3X2 inch 116 TEE 3X3 inch 117 TEE 3X4 inch 118 TEE 6X6 inch 119 NIPPLE 0.5X6 inch 120 NIPPLE 1X6 inch 121 NIPPLE 2X4 inch 122 NIPPLE 2X6 inch 123 NIPPLE 2X9 inch 124 NIPPLE 2X12 inch 125 NIPPLE 3X4 inch 126 NIPPLE 3X6 inch 127 NIPPLE 3X9 inch 128 NIPPLE 3X12 inch 129 ELBOW 0.5 inch 130 ELBOW 1 inch 131 ELBOW 1.5 inch 132 ELBOW 2 inch 133 ELBOW 2.5 inch 134 ELBOW 3 inch 135 ELBOW 4 inch 136 ELBOW 6 inch 137 FLANGE C.I.2 inch 138 FLANGE C.I. 3 inch 139 FLANGE C.I. 4 inch 140 FLANGE C.I. 6 inch 141 FLANGE G.I. 2 inch 142 FLANGE G.I. 3 inch 143 FLANGE G.I. 4 inch 144 FLANGE G.I. 6 inch 145 P V C PIPE0.5 inch 146 P V C PIPE1 inch 147 P V C PIPE1.5 inch 148 P V C PIPE2 inch 149 P V C ELBOW 0.5 inch 150 P V C ELBOW 1 inch 151 P V C ELBOW 1.5 inch 152 P V C ELBOW 2 inch 153 P V C SOCKET 0.5 inch 154 P V C SOCKET 1 inch 155 P V C SOCKET 1.5 inch 156 P V C SOCKET 2 inch 157 P V C UNION 0.5 inch 158 P V C UNION 1 inch 159 P V C UNION 1.5 inch 160 P V C UNION 2 inch 161 P V C BRASS SOCKET 0.5 inch 162 P V C BRASS SOCKET 1 inch 163 P V C BRASS SOCKET 1.5 inch 164 P V C BRASS SOCKET 2 inch 165 P V C BRASS ELBOW 0.5 inch 166 P V C BRASS ELBOW 1 inch 167 P V C BRASS ELBOW 1.5 inch 168 P V C BRASS ELBOW 2 inch
Contract Date: Apr 03, 2026 Contract Value : 3.87 Lakh
Local Bodies No of Bidders 4
Madhya Pradesh View Result →
28.
Heavy Industries and Public Enterprises #9940997 Technical Bid
Tender For U200 New Control Room Revamping-Brick work demolishing 2 Demolishing brick work manually / by mechanical means including stacking ofserviceable material and disposal of unserviceable material within 50 metres lead asper direction of Engineer-in-Charge.In lime mortar with old mughal bricks 3 RCC demolition 4 Demolishing R.C.C. work manually / by mechanical means including stacking ofsteel bars and disposal of unserviceable material with in 50 metres lead as perdirection of Engineer -in-Charge. 5 Pcc demolishing 6 Demolishing cement concrete manually / by mechanical means including disposal ofmaterial within 50 metres lead as per direction of Engineer - in-Charge.Nominalconcrete 1:4:8 or leaner mix ( including equivalent design mix) 7 Demolishing wooden door 8 Dismantling doors, windows and clerestory windows (steel or wood ) shutterincluding chowkhats, architrave, holdfasts etc. complete and stacking within 50metres lead:Of area beyond 3 sq. metres 9 Dewatering with pump 10 Bailing out water/slush using pump above 5HP and up to 10 HP, includingconveyance to site and erection, cost of fuel, lubrication oil and other stores, pay ofstaff etc complete. All deposits/slush shall be shifted to designated location with in1km lead 11 Demolishing old iron ventilators 12 Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. orR.B. work ( Payment shall be made on the cross sectional area of R.C.C. or R.Bwork) as per direction of Engineer-in-charge. 13 Demolishing existing wooden partition 14 Dismantling wooden boardings in lining of walls and partitions, excluding supportingmembers but including stacking with in 50 metres lead:Upto 10 mm thick 15 Demolishing false ceiling 16 Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking thematerial within 50 metres lead of :Asbestos cement Sheet 17 Excavation work 18 Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil 19 soling 20 Soling with rough stone of size 200 mm, well packed and filling voids with stonechips and required profile with hammer dressed stones having no side less than 15cm, with minimum depth of 20 cm includingpreparing the bedding surface etc. all complete 21 Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources) 22 RCC upto plinth level 23 Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size derived from natural sources) 24 Steel reinforcement work upto plinth level 25 Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelMild steel and Medium Tensilesteel bars 26 Solid block masonry upto plinth level 27 Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cmor nearest available size confirming to IS 2185 part I of 1979 for foundation andplinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etccomplete 28 Bituminous painting 29 Painting with black anti- corrosive bitumastic paint of approved brand andmanufacture to give an even shade:Two or more coats on new work 30 Red earth filling 31 Filling with contractors own earth ( excluding rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per directionof site Engineer-in-charge 32 RCC for column above plinth level 33 Reinforced cement concrete work in walls (any thickness), including attachedpilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. up tot floor five level excluding cost of centering,shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 gradedstone aggregate 20 mm nominal size derived from natural sources) 34 Solid block masonry 35 Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15cmor nearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level with thickness 15cm in :CM 1:6 ( 1 cement : 6 coarse sand) etc 36 RCC beam 37 Reinforced cement concrete work in beams, suspended floors, roofs, having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases up to floor five level excluding the cost of centering,shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (ZoneIII) derived from natural sources: 3 graded stone aggregate 20 mm nominal sizederived from natural sources). 38 Steel reinforcement above plinth level 39 Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Cold twisted bars 40 Plastering with 12mm cement plaster mix 1:4 41 Plastering with 12 mm cement plaster of mix: 1:4 (1 cement : 4 fine sand ) 42 Ceiling 43 Providing and fixing false ceiling at all height including providing and fixing of framework made of special sections, power pressed from M.S. sheets and galvanized withzinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting ofangle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mmdia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangersof 25x10x0.50 mm of required length with nuts & bolts of required size andother end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mmrunning at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular toG.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mmlong G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed towall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wallscrews @ 230 mm interval, including fixing of gypsum board to ceiling section andperimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c,including jointing and finishing to a flush finish of tapered and square edges of theboard with recommended jointing compound, jointing tapes, finishing with jointingcompound in 3 layers covering upto 150 mm on both sides of joint and two coats ofprimer suitable for board, all as per manufacturers specification and alsoincluding the cost of making openings for light fittings, grills, diffusers, cutouts madewith frame of perimeter channels suitably fixed, all complete as per drawings,specification and direction of the Engineer in Charge but excluding the cost ofpainting with:12.5 mm thick tapered edge gypsum moisture resistant board 44 Shuttering for footing 45 Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete 46 Shuttering for column above plinth level 47 Centering and shuttering including strutting, etc. and removal of form for:Columns,Pillars, Piers, Abutments, Posts and Struts 48 Shuttering for beams 49 Centering and shuttering including strutting, etc. and removal of form for:Lintels,beams, plinth beams, girders bressumers and cantilevers 50 Shuttering for slab 51 Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform 52 Shuttering for sunshade 53 Centering and shuttering including strutting, etc. and removal of form for:Weathershade, Chajjas, corbels etc., including edges 54 Shuttering for stair 55 Centering and shuttering including strutting, etc. and removal of form for:Stairs,(excluding landings ) except spiral - staircases) 56 Applying SBR latex mixed plaster and applying bonding agent 57 Providing, mixing and applying SBR polymer (of approved make such as NitobondSBR/SBR Reomix/Cera SBR Latex of M/s Fosroc/BASF/Cera Chem or Similiarrespectively) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer as per manufactures specification) including surface cleaning and application of bonding slurry to the prepared surface for proper adhesion as per manufacturers specificationas and directions of Engineer in chargeNote:Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made onlyafter proper wet curing has been done and surface has been satisfactorily evaluated by sounding /tapping with a blunt metal instrument of 12 mm average thickness includingscaffoldings upto 4 m height 58 Thixotropic Non shrink mortar 59 Providing and applying single component fibre reinforced thixotropic non shrinkrepair mortar such as BASF EMACO S48CT or FOSROC/BOSTIK product forcolumns, beams, slabs and otherstructural members with 4 ltrs of potable water per 25kg of product, mixing by heavyduty,slow speed drill with spiral mixing paddle or a Pan type mixers etc. afterpouring the water in a mixing vessel, mixed materialshall be applied both by trowel or spray application and finished to get a uniformthickness and finish and all works as per manufactures specifications and as directedby the Engineer in charge, including curing, cost of materials, labour, scaffoldingupto a height of 4 mtr, conveyance etcThe work shall be carried by an agency havingsufficient experience and should ensure a guarantee of 5years. Only skilled andexperienced persons shall be employed for this purpose. 60 Supply and laying first quality vitrified tiles of size 1200*600 61 Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including spacers 3mm and grouting the joints with epoxy which shall be paid extra., complete.Size of Tile 1200x600 mm 62 Epoxy grouting 63 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy groutmix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kgof resin per kg). including filling /grouting and finishing complete as per direction ofEngineer-in-charge.Size of Tile 600x600 mm or nearest 64 providing & fixing anti skid floor tile at toilet 65 Providing and fixing premium quality ceramic digital anti-skid floor tiles ofmake
Kajaria/Nitco/Simpolo/Cera or approved brand conforming to IS :15622 (thickness to be
specified by the manufacturer), in all colours, shadesof size matching to wall tiles or as approved by
Engineer -in-Charge, over12 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) with tilespacers 3mm and jointing with epoxy joint fillers with pigment of matchingshade of approved brand in approved pattern
with two or more desgin tilescomplete. 66 Providing & fixing premium quality ceramic digital wall tile 67 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar1:3 (1 cement : 3 coarse sand) and including spacers 3mm and grouting the joints with epoxy which shall be paid extra., complete 68 painting 69 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additivesof required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over andincluding priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 70 Window grill 71 Providing and fixing M.S. Grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steelprimer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc 72 Aluminium Frame work for Doors windows and partitions 73 Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dashfasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating50 micron) 74 Shutter for doors and windows 75 For shutters of doors, windows & ventilators including providing and fixinghinges / pivots and making provision for fixing of fittings wherever requiredincluding the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paidfor separately)Powder coated aluminium (minimum thickness of powder coating 50micron) 76 UV sheet for doors 77 Providing and fixing 4 mm thick UV sheet in panelling fixed in aluminum doors,windows shutters and partition frames with C.P. brass / stainless steel screws , UVSheet finished in two diffrent colours and complete as per architectural drawings anddirections of Engineer - in-Charge 78 Glass 79 Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mmthickness (weight not less than 10kg/sqm) 80 Lock for doors 81 Providing and fixing Brass100 mm mortice latch and lock with 6 levers without pairof handles ( best make of approved quality ) for aluminum doors including necessarycutting and making good etc. complete 82 Hinges 83 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade, with necessary screws etc. complete:100 mm 84 Handles 85 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade, with necessary screws etc. complete:100 mm 86 Tower bolts 87 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barreltype) with necessary screws etc. complete : (Copper oxidized as per IS : 1378)250x10mm 88 FRP door frame 89 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of30 mm thickness. The laminated shall be moulded with fire resistant gradeunsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mmthick and shall be filled with suitable wooden block in all the three legs. The frameshall be covered with fiber glass from all sides. M.S. stay shall be provided at thebottom to steady the frame. 90 FRP door shutter 91 Providing and fixing to existing door frames.30 mm thick Fiberglass ReinforcedPlastic (F.R.P) flush door shutter in different plain and wood finish made with fireretardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate allaround, with suitable wooden blocks inside at required places for fixing of fittingsand polyurethane foam (PUF) / Polystyrene foam to be used all filler materialthroughout the hollow panel, casted monoolithically with testing parameters of F.R.P.laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineerin-charge. 92 25 mm PVC concealed 93 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 25 mm pipe10kgf /cm2 94 32mm PVC concealed 95 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe10Kgf/cm2 96 50mm PVC concealed 97 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 50 mm pipe6 kgf/cm2 98 63mm PVC concealed 99 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge. Concealed workincluding cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2 100 32 mm pvc pipe exposed on wall 101 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mmdia 6 Kgf/cm2 - External work - Exposed on wall 102 50mm pvc pipe exposed on wall 103 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 6Kgf/cm2 - External work - Exposed on wall 104 110mm pvc pipe trenching and refilling 105 Providing and fixing PVC pipes includes joints of pipes with one step PVC solventcement, trenching, refilling & testing of joints complete as per direction ofEngineer in CHarge. 110 mm dia 4 Kg/cm2 106 63mm dia elbow 107 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement -63 dia 45 degree Elbow 108 63mm 45 degree elbow 109 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement -63 dia 45 degree Elbow 110 63 dia pvc door elbow 111 Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63 mm dia Door Elbow 112 63 dia tee 113 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipesincluding jointing with PVC solvent cement - 63x63x63 mm dia Tee 114 63mm dia pvc bend 115 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63 mm dia Bend 116 63mm dia door tee 117 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement -63x63x63 mm dia Door Tee 118 63mm dia vent cowl 119 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63 mm dia vent cowl 120 110-63mm pvc reducer 121 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement -110x63 mm dia Reducer 122 63x50mm pvc reducer 123 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63x50 mm dia Reducer 124 63mm dia socket/coupling 125 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63 mm dia End cap 126 63mm dia coupling 127 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63 mm dia End cap 128 110mm dia elbow 129 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Elbow 130 110mm dia 45 degree elbow 131 Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow 132 110 mm dia door elbow 133 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement-110 mm dia Door Elbow 134 110mm dia bend 135 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 110 mm dia Bend 136 110mm dia tee 137 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipesincluding jointing with PVC solvent cement 110x110x110 mm dia Tee 138 110mm dia door tee 139 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110x110x110 mm dia Door tee 140 110mm dia socket/coupling 141 Providing and fixing PVC moulded fittings/accessories for Rigid PVCpipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling 142 GM ball valve 143 Providing and fixing GM ball valve of approved quality (screwed end) :
25mm nominal bore 144 Providing and fixing CP brass bib cock long body 145 Providing and fixing C.P. brass long body bib cock of approved quality conforming toIS standards and weighing not less than 690 gms.15 mm nominal bore 146 Providing and fixing CP brass stop cock 147 Providing and fixing C.P brass stop cock ( concealed) of standard design and ofapproved make conforming to IS: 893115 mm nominal bore 148 CP brass angle valve 149 Providing and fixing C.P. brass angle valve for basin mixer and geyser points ofapproved quality conforming to IS: 893115 mm nominal bore 150 PVC ball valves 151 Providing and fixing PVC ball valve (ISI marked) of approved brand for Rigid PVCpipes, including jointing with PVC solvent cement:
25mm nominal bore. 152 CP brass shower rose 153 Providing and fixing C.P. brass shower rose with arm of 15 or 20 mminlet:
100 mm diameter 154 SS soap Dish 155 Supplying and fixing Stainless steel soap dish including cost of materials and labourcharges etc complete as per the direction of site Engineer-in-charge. 156 Towel rod 157 Supplying and fixing CP Towel rod 45cm or nearest available length including cost ofmaterials and labour charges etc complete as per the direction of site Engineer-incharge. 158 Health faucet 159 Supplying and fixing CP Health faucet good quality including cost of materials andlabour charges etc. complete as per the direction of site engineer-in-charge 160 CP gratings 161 Providing and fixing CP grating of approved quality.
Rectangular type withopenable circular lid
150 mm nominal size square 100 mm diameter of theinner hinged round grating 162 Floor trap 163 Providing and fixing PVC moulded Floor trap for sanitary pipelines, including jointing PVC pipes with PVC solvent cement and filling gaps with cement groutFloor trap 4 way/3 way 164 Labour charge 165 Miscellaneous labour 166 ISMB 200 167 Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.)trusses etc., including cutting, hoisting,fixing in position and applying a priming coatof approved epoxy primer and 2 or more coats of epoxy paint, including welding andbolted with special shaped washers etc. complete 168 Steel reinforcement paint 169 Providing and applying anti corrosive Nitozinc primer/Cera cte SP CI/ protectosilCIT, two or more coats, over the steel reinforcement as per the manufacturesspecification including scaffolding upto height 4 mtr and as directed by Engineer-incharge. The product shall be applied on the reinforcement surface after throughlycleaning. painted area of steel shall be considered for payment 170 Orissa pattern W.C. pan 171 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mmSand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, includingflush pipe, manually controlled device (handle lever) conforming to IS : 7231, withall fittings and fixtures complete, including cutting and making good the walls andfloors wherever require:White Vitreous china Orissa pattern W.C. pan of size580x440 mm with integral type foot rests 172 Providing and fixing white vitreous china pedestal type water closet (European typeW.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, includingflush pipe, with manually controlled device (handle lever), conforming to IS : 7231,with all fittings and fixtures complete, including cutting and making good the wallsand floors wherever required:W.C. pan with ISI marked black solid plastic seat andlid 173 providing & fixing mirror 174 Providing and fixing mirror of superior glass ( of approved quality) and of requiredshape and size with plastic moulded frame of approved make and shade with 6 mmthick hard board backing :Rectangular shape 453x357 mm 175 providing & fixing wash basin 176 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Flat backwash basin size 450x300 mm with single 15 mm C.P. brass pillar tap 177 Tap pvc PTMT 178 Providing and fixing PTMT bib cock of approved quality and colour.15 mm nominalbore, 86 mm long, weighing not less than 88 gms 179 Providing new septic tank 180 Supplying and installing ready made RCC Septic tank including the cost of carriage,trenching, placing at the level below ground level as specified as per the direction ofengineer in charge incl supply of CC/Sand/06mm aggregate for the preparation of bed) 35 to 50 flush capacity 181 SUPPLY PARTDISTRIBUTION BOARDS 182 Supply of 63A, 3 phase 415V 4 way Verical Distribution boardIn sheet steel enclosure with double door and detachable gland plate, complete with cable entry adaptor box, tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs etc. as requiredFor surface mountingWith 63A, 4 pole MCCB as incomer and 1 No.s of 40A 4 pole MCCBs and 2 No. of 32A 4 pole MCCB as outgoing (Including required dummy to close the vaccant spaces)Make of DB: Standard/Havells/ABB/Siemens/Hager/SchneiderMake od MCCB/MCB: Standard/Havells/ABB/Siemens/Hager/Schneider 183 Supply of 40A, 3 phase 415V 4 way Horizontal Distribution boardIn sheet steel enclosure with double door and detachable gland plate, complete with cable entry adaptor box, tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs etc. as requiredFor surface mountingWith 40A, 3 phase 4P MCB & 40A, 30mA 3 phase RCCB as incomer and 9 No.s of 20A SP MCBs as outgoingMake of DB: Standard/Havells/ABB/Siemens/Hager/SchneiderMake od MCCB/MCB/RCCB: Standard/Havells/ABB/Siemens/Hager/Schneider 184 Supply of 25A, 3 phase 415V 6 way Horizontal Distribution boardIn sheet steel enclosure with double door and detachable gland plate, complete with cable entry adaptor box, tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs etc. as requiredFor surface mountingWith 25A, 3 phase 4P MCB & 25A, 30mA 3 phase RCCB as incomer and 12 No.s of 6A SP MCBs as outgoing (Including required dummy to close the vaccant spaces)Make of DB: Standard/Havells/ABB/Siemens/Hager/SchneiderMake od MCCB/MCB/RCCB: Standard/Havells/ABB/Siemens/Hager/Schneider 185 LIGHTING AND WIRING.LIGHT FIXTURES AND FANS, SWITCHES AND SOCKETS 186 Supply of LED downlight round (Approximate cutout dia 15cm), 10W (Approximate), 230V, 50Hz AC supply, with spring buckle for concealed false ceiling mounting, Lumen efficacy: 100 Lumens/W or above, Lumens: 1000 Lumens or above, THD: 15% or less, PF: 0.90 or above, CRI: 80 or above, Colour temperature: Cool White(5500-6500K), IP: 20 or above, Warranty: Full warranty of 1 year or above 187 Supply of LED downlight round (Approximate cutout dia 20cm), 20W (Approximate), 230V, 50Hz AC supply, with spring buckle for concealed false ceiling mounting, Lumen efficacy: 100 Lumens/W or above, Lumens: 2000 Lumens or above, THD: 15% or less, PF: 0.90 or above, CRI: 80 or above, Colour temperature: Cool White(5500-6500K), IP: 20 or above, Warranty: Full warranty of 1 year or above 188 Supply of LED wall light, 10W (Approximate), 230V, 50Hz AC supply, with spring buckle for concealed false ceiling mounting, Lumen efficacy: 100 Lumens/W or above, Lumens: 1000 Lumens or above, THD: 15% or less, PF: 0.90 or above, CRI: 80 or above, Colour temperature: Cool White(5500-6500K), IP: 20 or above, Warranty: Full warranty of 1 year or above 189 Supply of LED mirror light, 10W (Approximate), 230V, 50Hz AC supply, with spring buckle for concealed false ceiling mounting, Lumen efficacy: 100 Lumens/W or above, Lumens: 1000 Lumens or above, THD: 15% or less, PF: 0.90 or above, CRI: 80 or above, Colour temperature: Cool White(5500-6500K), IP: 20 or above, Warranty: Full warranty of 1 year or above 190 Supply of LED tube light batten, 4 feet, 20W (Approximate), 230V, 50Hz AC supply, Lumen efficacy: 100 Lumens/W or above, Lumens: 2000 Lumens or above, THD: 15% or less, PF: 0.90 or above, CRI: 80 or above, Colour temperature: Cool White(5500-6500K), IP: 20 or above, Warranty: Full warranty of 1 year or above 191 Supply of Exhaust Fan, 225 mm sweep Make:USHA/CROMPTON/BAJAJ/ORIENT/KHAITHAN/HAVELLS 192 Supply of CEILING FANMOTOR TYPE: BLDC230 V, 50 HZ, AC, 1200 MM SWEEP WITH REMOTE CONTROL AND ALL ACCESSORIESSTAR RATING: 5MAKE: ATOMBERG/CROMPTON/HAVELLS/ORIENT/LUCAS/HALONIX. 193 Supply of Electric calling bell, 230V, 50HzMake:Anchor/havells/L&T/Legrand 194 Supply of Bell switch, for 1 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell 195 Supply of 6A switch, for 1 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell 196 Supply of 25A switch, for 1 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell 197 Supply of 6A Socket, for 2 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell 198 Supply of 25A Socket, for 2 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell 199 Supply of RJ11 Socket, for 1 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell 200 Supply of RJ45 Socket, for 1 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell 201 Supply of Concealed box, Plate and frame for 2 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell 202 Supply of Concealed box, Plate and frame for 3 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell 203 Supply of Concealed box, Plate and frame for 4 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell 204 Supply of Concealed box, Plate and frame for 6 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell 205 Supply of Concealed box, Plate and frame for 12 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell 206 Modular type wiring 207 Supply of materials required for copper point wiring for lights, fans and exhaust fan in recessed PVC medium gauge conduit with modular type switch - using 1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Fans, Exhaust fans, Lights, Concealed mounting boxes, Plates and Frames, Switches and Sockets)(Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.) 208 Supply of materials required for copper point wiring for 25A sockets in recessed PVC medium gauge conduit with modular type switch - using 2.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 2.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Switches, Sockets)(Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.) 209 Supply of materials required for copper point wiring for calling bell in recessed PVC medium gauge conduit with modular type switch - using 1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Switches, Sockets)(Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.) 210 Supply of materials required for circuit wiring for RJ11 in PVC medium gauge conduit with modular type switch - using telephone cable (twin flat copper PVC insulated, 2 x 0.5 sq mm, ISI marked, Make: Finolex, Anchor, V-guard, Traco, Sark, Orbit, Polycab) in recessed PVC conduit with modular type socket with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Sockets) 211 Supply of materials required for circuit wiring for RJ45 sockets in PVC medium gauge conduit with modular type switch - using CAT 6 UTP cable (Make: D-link, Finolex, Polycab, Lapp) in recessed PVC conduit with modular type socket with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Sockets) 212 Supply of materials required for wiring for Smoke Detectors in recessed PVC medium gauge conduit - using 3 x 1 sq. mm. PVC insulated copper cable in recessed PVC conduit with modular type socket with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Smoke detector)(Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.) 213 Supply of materials required for copper point wiring for lights, fans and exhaust fan in recessed PVC medium gauge conduit with modular type switch - using 1.5 sq. mm. PVC insulated copper conductor stranded cable in srecessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Fans, Exhaust fans, Lights, Concealed mounting boxes, Plates and Frames, Switches and Sockets). (For exceeding 5 meter point wiring. Tthis will be in addition to point wiring rate above).(Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.) 214 Supply of materials required for copper point wiring for 25A sockets in recessed PVC medium gauge conduit with modular type switch - using 2.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 2.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Switches, Sockets). (For exceeding 5 meter point wiring. This will be in addition to point wiring rate above).(Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.) 215 Supply of materials required for copper point wiring for calling bell in recessed PVC medium gauge conduit with modular type switch - using 1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Switches, Sockets). (For exceeding 5 meter point wiring, this will be in addition to point wiring rate above).(Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.) 216 Supply of materials required for Copper circuit wiring in PVC conduit - Circuit Wiring with 1.5 sq.mm PVC insulated, copper conductor, stranded cable in recessed PVC conduit along with 1 no. 1.5 sq. mm. PVC insulated copper wire for loop earthing as required. 217 Supply of materials required for Copper circuit wiring in PVC conduit - Circuit Wiring with 2.5 sq.mm PVC insulated, copper conductor, stranded cable in recessed PVC conduit along with 1 no. 2.5 sq. mm. PVC insulated copper wire for loop earthing as required. 218 Supply of 10 pair telephone junction box and accessories for surface mounting, Make: Syntex, Krone 219 INSTALLATION PARTModular type wiring and Installation 220 Installation, testing and commissioning of LED downlight of all types complete with all accessories etc. in false ceiling including connection with 1.5 sq.mm PVC insulated copper conductor single core cable etc. as required. 221 Installation of ceiling fans, making connections, testing and commissioning etc. with 1.5 sq.mm PVC insulated copper conductor single core cable etc. as required 222 Installation of exhaust fan upto 300 mm sweep in the existing opening including making the holes to suit the size of the above fan making good the damage, connections, testing and commissioning etc. with 1.5 sq.mm PVC insulated copper conductor three core cable etc. as required 223 Installation, testing and commissioning of LED tube lights, wall lights and mirror lights of all types complete with all accessories etc. including connection with 1.5 sq.mm PVC insulated copper conductor single core cable etc. as required. 224 Installation of calling bell at DCW room, making connections, testing and commissioning etc. with 1.5 sq.mm PVC insulated copper conductor single core cable etc. as required 225 Installation, testing and commissioning of Smoke Detectors complete with all accessories etc. including connection with 1.5 sq.mm PVC insulated copper conductor three core cable etc. as required. 226 Fixing of 6/25 amps modular type sockets, switches, bell switches, RJ11 and RJ45 modular sockets (other than included in point wiring) with front plate in surface or in recess including providing and fixing suitable size metal box, inter connections etc as required. 227 Copper point wiring in PVC medium gauge conduit with modular type switch - Wiring for light point/fan point/exhaust fan point using 1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. 228 Copper point wiring in PVC medium gauge conduit with modular type switch - Wiring for socket point using 2.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 4 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. 229 Copper point wiring in PVC medium gauge conduit with modular type switch - Wiring for calling bell point using 1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. 230 Copper point wiring in PVC medium gauge conduit for Smoke Detector - Wiring for smoke detector point using 1/1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1/1.5 sq. mm. PVC insulated copper 3 core cable as required 231 Copper point wiring for lights, fans and exhaust fan in recessed PVC medium gauge conduit with modular type switch - using 1.5 sq. mm. PVC insulated copper conductor stranded cable in srecessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Fans, Exhaust fans, Lights, Concealed mounting boxes, Plates and Frames, Switches and Sockets). (For exceeding 5 meter point wiring. Tthis will be in addition to point wiring rate above). 232 Copper point wiring for 25A sockets in recessed PVC medium gauge conduit with modular type switch - using 2.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 2.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Switches, Sockets). (For exceeding 5 meter point wiring. This will be in addition to point wiring rate above). 233 Copper point wiring for calling bell in recessed PVC medium gauge conduit with modular type switch - using 1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Switches, Sockets). (For exceeding 5 meter point wiring, this will be in addition to point wiring rate above). 234 Copper circuit wiring in PVC conduit - Circuit Wiring with 1.5 sq.mm PVC insulated, copper conductor, stranded cable in recessed PVC conduit along with 1 no. 1.5 sq. mm. PVC insulated copper wire for loop earthing as required. 235 Copper circuit wiring in PVC conduit - Circuit Wiring with 2.5 sq.mm PVC insulated, copper conductor, stranded cable in recessed PVC conduit along with 1 no. 2.5 sq. mm. PVC insulated copper wire for loop earthing as required. 236 LAN circuit wiring in PVC conduit - Circuit Wiring with UTP/Ethernet cable in recessed PVC conduit as required. 237 Telephone circuit wiring in PVC conduit - Circuit Wiring with two core telephone cable in recessed PVC conduit as required. 238 DB installation and Cabling 239 Installation, testing and commissioning of 63A, 3 phase 415V 4 way Verical Distribution boardIn sheet steel enclosure with double door and detachable gland plate, complete with cable entry adaptor box, tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs etc. as requiredFor surface mountingWith 63A, 4 pole MCCB as incomer and 1 No.s of 40A 4 pole MCCBs and 2 No. of 32A 4 pole MCCB as outgoing (Including required dummy to close the vaccant spaces)Make of DB: Standard/Havells/ABB/Siemens/Hager/SchneiderMake od MCCB/MCB: Standard/Havells/ABB/Siemens/Hager/Schneider 240 Installation, testing and commissioning of 40A, 3 phase 415V 4 way Horizontal Distribution boardIn sheet steel enclosure with double door and detachable gland plate, complete with cable entry adaptor box, tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs etc. as requiredFor surface mountingWith 40A, 3 phase 4P MCB & 40A, 30mA 3 phase RCCB as incomer and 9 No.s of 20A SP MCBs as outgoingMake of DB: Standard/Havells/ABB/Siemens/Hager/SchneiderMake od MCCB/MCB/RCCB: Standard/Havells/ABB/Siemens/Hager/Schneider 241 Installation, testing and commissioning of 25A, 3 phase 415V 6 way Horizontal Distribution boardIn sheet steel enclosure with double door and detachable gland plate, complete with cable entry adaptor box, tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs etc. as requiredFor surface mountingWith 25A, 3 phase 4P MCB & 25A, 30mA 3 phase RCCB as incomer and 12 No.s of 6A SP MCBs as outgoing (Including required dummy to close the vaccant spaces)Make of DB: Standard/Havells/ABB/Siemens/Hager/SchneiderMake od MCCB/MCB/RCCB: Standard/Havells/ABB/Siemens/Hager/Schneider 242 Laying, dressing and clamping of following cables through exsisting trays / structures / racks / columns / walls etc to the new DB .Cable shall be supplied by KMML. All other materials required for clamping are under the scope of contractor. 243 (3.5 x 25 to 3.5 x 50) sq. mm AYFY/XLPE cable 244 Glanding and termination at DBs side of PVC cable using DC glands/ lugs including supply of cable glands, lugs, aluminium crimping sockets, nuts bolts etc. required for this work. Gland earthing as per standards shall be done by the contractor. 245 (3.5 x 25 to 3.5 x 50) sq. mm AYFY/XLPE cable 246 Telephone switch relocation 247 Installation, testing and commissioning of 10 pair telephone junction box and accessories for surface mounting, Make: Syntex, Krone 248 Approval from Electrical Inspectorate. 249 Preparation of all electrical drawings and obtainig statutory approval from electrical inspectorate for the new DBs Please Enable Macros to View BoQ information
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
30.
Defence #9920439 AOC
Tender For Special Repairs To Shaft Spaces Of Po 16 (Annex Building); 1 Note:(i) The rate should be Quoted considering the high rise nature of buildingand necessary scaffolding and safety precaution.(ii) Entire building to be covered with green cloth on MS scafFolding uptoTOP floor and necessary precaution sign board to be placed around the building before commencement and completiom of work.(iii) Debries removed outside Mod Land. 2 M&L for Chipping , removing carefully concrete work by low impact hammer ,breakar without damaging the structure & cleaning and disposal of debries out side the premises etc. complete as directed by Engr-in-Charge. Hard concrete should not be removed by force. 3 M&L for Cleaning existing reinforcement with wire/ rotary wire brush, making the surfaces free from loose material dirt etc. complete and applying two coats of alkaline rust converting primer of approved make on the rebars, including cleaning the reinforcement, wirebrushing to remove loose rust spalls, wash the rebars with clean water within 3 min and wipe it dry. 4 M&L for applying two coats of Epoxy based Zinc primer in a span of four hours over the treated rebars and allow to dry for six hours.The application shall be by brush.epoxy primer for steel of approved make zinc primer. 5 M&L for cleaning all loose laitance on the concrete substrate and applying one coat of epoxy bonding agent on exposed concrete surface to ensure bond between old concrete & new concrete by brush application. Of approved make. 6 M&L for rendering minimum 20mm thick polymer modified mortar in cemet mortar (1:3) with graded quartz sand with additive Monolith - PMM of approved make. 15% by weight of cement in one coat with and including curing as per manufacturers instruction complete all as specified and as directed. 7 M&L for Providing and applying water tight jacketing around columns with M30 grade micro concrete including all lifts, shuttering, drilling holes and fixing shear anchor as per specification complete. of approved make.(Note:Reinforcement shall be measured and paid separately) 8 M&L for applying concrete protection coating on finished structural members exposed to atmosphere of approved make complete all as specified and directed. 9 M&L for Drilling and fixing Rohibb Teflon nozzles in RCC members, including drilling holesof 12mm dia, 50 to 100mm deep holes.Works shall be carried out as under :- (i) Cleaning ofholes. Clean the holes by air blower prior to fixing nozzles.(ii) Fixing of nozzles. Insert 12mm dia. Rohibb Teflon nozzles in cleaned holes. External end of nozzles to be machine to receive outlet of grouting gun.Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for min.12 hrs. (iii)Cutting of nozzles.Cut the nozzles by chisel after completion of grouting without damaging structural elements.(iv) In case crack upto 2mm wide, fix the injection nozzels directly over the cracks, at intervals of 6 to 9 inches, using a drilling machine. Fix PVC/MS nozzels in these holes with fast-setting epoxy putty & let it dry for 2 to 3 days. Also, seal the crack between the ports with epoxy putty.(v) In case where the crack is wider than 2mm upto 4 to 5mm, drill holes at the sides of the crack in a staggered fashion, at intervals of 6 inches and affix them with epoxy putty as mentioned above.(vi) Also, seal the face of the carck with a liberal application of the epoxy putty. 10 M&L for Injecting of site mixed cement slurry grout, mixed in specified proportion containing cement, sand water with addition of plasticizers (approved make) & migratory corrosion inhibitors, water cement ratio shall be varied between 0.5 to 1.0 for each hole, shrinkage compensating cement slurry mixed to a lump free fresh creamy consistency ,Mixing shall be done by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of approved/specified grout by means of pump at a pressure of 3-5 Kg/cm2 etc complete till the grout mix flows out from the nozzle indicating complete filling of grout in the holes drilled of approved make. 11 M&L for Injecting low viscosity (3-5cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories till nozzles refuses to accept the grout, Including,Mixing of materialas:Mixing of material components(part a&b) inthe required quantities as per manufacturers instruction by weigh batching.Grouting:Fill the grouting gun with concrete penetrating corrosion inhibitor EPCO-KP-100/Protectsil CIT or Ferogard 903. Maintain desired pressure in the gun by air compressor; maintain the pressureat exit(2 to 3kg/cm2) by monitoring pressure guage at exit.Grout the material through prefixed nozzles in the structural elements@ 100ml per nozzle. Repeat the process for all the nozzles. 12 M&L for Replacement of steel reinforcement with TMT bars of appropriate size where 30% of cross section is reduced including dismantling of rusted steel complete all as specified and directed. 13 M&L for Providing and fixing additional main steel bar or stirrups of designed diameter in various structural elements like column ,beams and foundations including drilling ,bending and fixing the bars with epoxy putty etc. complete (Steel provided on the basis of 1% of volume of concrete). 14 M&L for Cleaning the dust, vegetation, sand,dry leaves and other waste material at the rain water pipe of any size and any description, spouts, water outlets of the roofs etc as directed and dispose off debris at a distance of 500km and n.exc 1.5 Kmincluding taking down and refixing of existing pipes including necessary fixing arrangements. 15 Taking down cast iron pipes of any size or pattern at any position including all fittings such as bends, heads (measured overall as fixed along the centre line over fiitings and accessories) including removing vegetation growth around pipes as required, making good to surface to match with eixisting including necessary scaffolding etc complete all as specified and directed. 16 S&F 100mm dia cast iron soil waste and vent pipes (sand cast pipes) in any length with or without ears with cement joints fixed to walls including MS scaffolding all as specified and directed. 17 S&F 75mm bore cast iron soil waste and vent pipes (sand cast pipes) in any length with or without ears with cement joints fixed to walls including MS scaffolding all as specified and directed. 18 S&F CI bends 75mm dia size diminishing pieces or trapers (larger bore measured) fitted with oval access doors including MS scaffolding all as specified and directed. 19 S&F CI bends 100mm dia size diminishing pieces or trapers (larger bore measured) fitted with oval access doors including MS scaffolding all as specified and directed. 20 S&F CI branch pieces single (equal or unequal) ordinary or inverted ( spigot or socket type) or with parallel branches of 75mm sizes including MS scaffolding all as specified and directed. 21 S&F CI branch pieces single (equal or unequal) ordinary or inverted ( spigot or socket type) or with parallel branches of 100mm sizes including MS scaffolding all as specified and directed. 22 Ditto all as per Srl ietm No. 20 above but double socket 23 Ditto all as per Srl ietm No. 21 above but double socket 24 Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof /wall coveringsand removing Dismantaled materials such as serviceable / unservicesble Plain or corrugated steel sheeting,etc. out side MoD land and rubbish off the premises complete all as specified and as directedby the Engineer-in-Charge. 25 S&Fpre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0..50mm thick of any colour with two corrugations side laphaving tensile strength of minimum 550 Mpa as in roof covering /cladding to wall, fixed withscrewall as specified and as directed 26 S&F pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.5mm thick of any colour having tenstile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed 27 Dismantling wrought iron or mild steel complete all as specified and as directed 28 S&F MS sections as in imsc,angle, main and cross beams, hip and jack rafters; purlins,rolled section where connected to common rafters and running rails and guides for truss/column/ staircase/ladder/anchor bolt for column/base plates/gussatte plates, wind tie,door,gate,window etc including cutting welding etc, fixed with angle cleats or other connecting plates complete all as specified and directed. 29 M&L for preparing new or previously untreated surface of any description, over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. 30 M&L for preparingnewplasteredsurfacesof walls and applyingtwo coatsofoil bound distemper over a coat of approved primer on plastered surfaces complete all as specified and directed. 31 M&L for preparing new surfaces of walls and applying two coats of acrylic (antifungal) exterior grade paint over one coat of primer complete all as specified. 32 M&L for complete removal of existingRCC Grill And Jali and fixing new premium quality heavy duty WPC designer jali/grill thickness 30mm and above including all necessary connected items such as SS nail,double rebate WPC frame work cross section size not less than 125x80mm standard grade density 800 kg/cm,ss safty clips, also repair beam and column with smart care material such as micro concrete, polimer modified plaster,reinforcement including chipping removal and paint the surface complete all as specified and directed. 33 Demolition of brick work/stone masonry built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles including coping complete all as specified and directed. 34 M&L brick work with sub class B bricks old size, full or half bircks works straight or curved on plan exc 6m mean radius in cement mortar 1:4 complete all as specified. 35 Taking down cement plaster on brick wallincluding raking out joints, hacking for key, scrubbing down with water, etc and removing taken down materials such as cement plaster,etc. out side MOD accomodation land and rubbish off the premises complete all as specified and as directedby the Engineer-in-Charge. 36 M&L prepration of old plastered / decorated surfaces of walls and applying two coat of oil bound distemper on plastered/decorated wall surfaces including 3mm thick wall care putty complete all as specified and directed. 37 Ditto_ all as per Sl item No 36 herein before but on ceiling etc complete all as specified 38 M&L prepration of old plastered / decorated surfaces of walls & ceiling and applying two coat of plastic emulsion paint on old plastered surfaces including MS scaffolding complete all as specified and directed. 39 M&L for preparation of old painted surfaces of wood or wood based surfaces over 10 cms width or girth and applying two finishing coat of synthetic enamelpaint on wooden surfaces complete all as specified and directed. 40 M&L for preparation of old painted surfaces of steel any description over 10 cms width or girth and applying two finishing coat of synthetic enamelpaint on steel surfaces including MS scaffolding complete all as specified and directed. 41 M&L for preparation of old wall surfaces of any description & applying one coats of acrylic (antifungal) exterior grade paint on wall/roof including MS scaffolding complete all as specified and directed 42 Taking up and down 15 mm boreGI tubing and connection including cleaning for re-fixing or removing to store including ss clamping and MS scafolding completeall asspecified and directed. 43 _Ditto_allasperSl item No. 42 hereinbeforebut20 mmbore completeall asspecified and directed. 44 _Ditto_allasperSl item No. 42 hereinbeforebut25 mm or 32 mmbore completeall asspecified and directed. 45 _Ditto_allasperSl item No. 42 hereinbeforebut40 mm or 50 mmbore completeall asspecified and directed. 46 S&F tubesmedium gradegalvanisedwithallfittingand fixedcomplete to wallsandceilingorlaidinfloors15 mm boreofpipe including ss clamping and MS scaffolding completeall asspecified and directed. 47 _Ditto_allasperSl item No. 46hereinbeforebut20 mmboreof pipe 48 _Ditto_allasperSl item No. 46hereinbeforebut25 mmboreof pipe 49 _Ditto_allasperSl item No. 46hereinbeforebut40 mmboreof pipe 50 Taking down eaves gutters and rainwater pipes( any size or pattern) , including all fittings, heads, shoes, bends , swan necks, etc, removal to store (measured overall as fixed along the centre line over fittings and accessories) including ss clamping and MS scaffolding. 51 S &F 160 mm dia PVC (SWR) pipes single socketedin any length with rubber ring joints fixed to wall complete including ss clamping and MS scaffolding all as specified and directed. 52 S &F 110 mm dia PVC (SWR) pipes single socketedin any length with rubber ring joints fixed to wall complete including ss clamping and MS scaffolding all as specified and directed. 53 S &F 75 mm dia PVC (SWR) pipes single socketedin any length with rubber ring joints fixed to wall including ss clamping and MS scaffolding complete all as specified and directed. 54 S&F for PVC (SWR) bends any radius 160mm bore complete all as specified and as directed 55 S&F for PVC (SWR) bends any radius 110mm bore complete all as specified and as directed 56 S&F for PVC (SWR) bends any radius 75mm bore complete all as specified and as directed
Contract Date: Jan 19, 2026 Contract Value : 34.45 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Maharashtra View Result →
31.
Defence #9920426 AOC
Tender For Special Repairs To The Existing Boundary Wall Of Mh Devlali And Certain Lbw Works Under The Aor Of Ge Deolali; 1 Demolition of brick work stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified. 2 M&L for brick work with fly ash old size bricks, straight or curved on plan n.exc 6m mean radius, built in cm 1:6 complete all as specified and directed. 3 Ditto above but except bricks complete all as specified and directed 4 Taking down cement mortar/plastering on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, incl removing of surbs vegetation for up to working space etc. 5 M&L for rendering on fair faces of brick or concrete work 15mm thick in CM 1:4 and to be finished smoothfor external surfacecomplete all as specified and as directed by Engr-in-Charge. 6 Dismantling of posts or struts (wood, steel or RCC) any section embadded in concrete, including taking out embedded portion and making good disturbed groundall as specified and as directed. 7 Material and labour for PCC (1:4:8), type D-2 using 40 mm graded stone aggregate as in posts (including caps & bases), foundation including formwork complete all as specified and directed. 8 Material and labour for PCC (1:2:4), type B-1 using 20 mm graded stone aggregate as in coping, bed block for fixing of angle iron fencing post on wall or similar works,plinth course,string courses,lacing courses,parapets and railing,apex stone,bed plates etc including formwork complete all as specified and directed. 9 Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed. 10 Supply and fixing mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or rivetting etc. and similar works conforming to Fe-290 (Gde E-165)complete all as specified and directed complete all as specified and directed. Note:- 1. Flat iron for securing wire mesh to be provided is to measured in this item. 2. Machine made screw bolt 10mm dia exceeding 5cm and not exceeding 10cm long shall be measured and paid seperately. 11 M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide all as specified and directed. 12 Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, shafts, wells, cesspits, manholes, laying pipe line, laying of cables or fixing poles and stays and struts etc. not exceeding 10 Sqm on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and directed. 13 Returning and filling including spreading, leveling watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and directed. 14 Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed. 15 S & F 10mm dia TMT bars and over cut to length bent to shape required including craking bending, spirally for hooping for columns, hooking ends and binding with mild steel wire ( annealed) not less than 0.90mm dia of wire or secruing with complete all as specified and directed. 16 S & F 5mm dia TMT bars and over upto and including 10mm dia asin stirrups, spacers and binders, spaces etc complete all as directed. 17 Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for .Note- Rate includes for reinforcement cutting as required to facilitate demolition. 18 M&L for providing RCC (1:2:4) using 20mm graded stone aggregate as in coping, slab supported on wall, beam, lintels etc incl necessary formwork for sides and bottom and scafolding as required complete all as directed by Engrin charge. 19 M&L for preparation of surface of wall and applying two coat of exterior weather proof (on putty surface)100% anti fungal acrylic smooth emulsion with silicon additives that offer anti alge high performance exterior wall finish with 5 years of performance warranty by manufacturer applied by using Airless spray technology with max working pressure of 3300 PPSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacture with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper, should be able to spray in hard to reach areas and penetration of distemper on the surface to achieve excellent application using limited manpower complete all as specified and directed. Make: Asian (apex ultima), Berger (wather coat), nerolac (excel total) 20 S & F in repairs galvanized 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing & straining & fixing to any type of standards rails straining bolts including securing or tying at crossing with & provn of galvanized mild steel wire complete all as specified anddirected. (Each line wire to be measured) 21 Excavation in trenches nexc 1.5 m width and nexc 1.5 m in depth for foundation etc or far shafts,wellset nexc 10 sqm on plan and nexc 1.5 m in depth and getting out in any type of soil. 22 Excavation over area n exc 1.5M deep and getting out in soft/loose soil complete and directed complete all as specified and directed. 23 Excavation over areas exc 1.5M deep and nt exc 3.0M deep and getting out in hard/dense soil complete and directed complete all as specified and directed. 24 Excavation over areas exc 1.5M deep and nt exc 3.0M deep and getting out in hard/dense soil complete and directed complete all as specified and directed. 25 M&L cement concrete 1 : 4 : 8 type D-2 using 40mm graded stone aggregate as in fdn, filling & mass concrete complete all as specified and as directed. 26 M&L forForming embankments including raising(orlowering)earth,spreading in layers n exc. 30 cm thick; watering,ramming/rolling and finishingto requiredsize, shape,etc., n exc. 1.5 m high from base all as specified and directed by Eng-incharge. 27 M&L for stone masonary walling of random rubble uncoursed ,well bonded, beded and solidly hearted built in CM 1:6 28 M&L for boulder pitching, grouted with cement and sand mortar including boulders all as specified and directed by engr incharge 29 M&L for Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses all as specified and directed by Engr in charge. 30 M&L for Raised pointing to random or polygonal rubble, uncoursed orbrought upto courses with cement mortar (1:4) all as specified and directed by Engr in charge. 31 S&F for 110mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid on wall complete all as specified and as directed. 32 Providing precastce- ment concrete (1:2:4)in bond stone (in retaining walls) win- dow or door cills,lintels,bressumers,steps,quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts,boundary pillars, bed plates, pintle blocks,ancho-rage blocks, bonders (for stone walling). corbels, brackets, etc. (of any section indicated), with plain fair faces, includingchamfers, weatherings, throat- ing etc. and setting in cement mortar(1:4) complete with joints to match all as specified and directed by Engr in charge. 33 M&L for cementconcrete 1:2:4 type B-1, using 20mm graded stone aggregate as in coping, bed blocks, filling of hold fast PCC or similar works including formwork complete all as specified and directed. 34 Formwork to edges of concrete flats, treads, breaks in floors window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide all as specified and directed by Engr -incharge 35 M&L RCC 1:2:4 type B1 ( using 20mm graded crushed stone aggregates) as inBeams, cantilevers, bressummers, lintels over 1.5m span 36 M&L for Rendering in 15mmin CM1:6on brick work or concrete surfaces etc finished surfaces even and smooth complete all as specifed and directed. 37 S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0all as specified and as directed. 38 M&L for precast cement concrete 1:2:4 type B1, (using 20mm graded stone aggregates) as in manhole cover slab set in CM (1:6) complete all as specified and directed. 39 M&L for mild steel work in reinforcement TMT bars , 10 mm dia and over as in reinforcement cut to length, bent to shape required including cranking, bending & hooking ends and binding with mild steel wire (annealed) not less than 0.9mm diacomplete all as specified and directed. 40 M&L for mild steel work in reinforcement TMT bars , 5 mm dia and over upto and including 10 mm dia as in stirpups ,spacers and binders as in reinforcements cut to length, bent to shape required including cranking, bending hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. 41 M&L RCC M-25 design mix as in Slabs supported on walls beams and columns in floors roofs, landings(using 20mm graded stone aggregates) complete all as specified and directed. 42 M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs landings and similar work not exceeding 200mm thick (Horizontal or slopping) with fair finished curved surfaces 43 M&L for drilling/boring vertical bores with reverse rotary rig are any other suitable method as per latest enginerring technology practice without casing pipe with202mm dia bit to a depth exceeding 30 m and not exc 40m below ground level includiing all necessary work required for boring and filling of pea gravels all round the lowered pipe etc complete all as specified and directed. Note (i) depth of boring shall be measured from of rechargewell. (ii) Pea gravels for filling shall be measered and paid for seperately 44 S&F machine pressed precast concrete interlocking paver block rubber moulded, any shape and size confirming ti IS-15658-2006 of 60mm thickness grey cement and withpigment , M-35 gradeincl30mm thick Sand filling to under interlocking tiles complete all as specified and directed. 45 M&L broken half burntbricks loose filling with aggregates of guage 80 to 150mm in soakage pits soakage well ,rainwater harvesting pits complete 46 M&L for broken stone boulderof gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick,wateredand rammed to a true surface 47 M&L for loose filling with pea gravel of size 1/8 to 3/8 to as in filter bed complete all as specified 48 S & F UPVC(sch-40) slotted pipe 200 mm outer dia including bends and fittings etc placed in bore holes complete all as specified and directed. 49 M & L for uPVCslotted pipe 100 mm outer dia including bends and fittings laid in trenches complete all as specified and directed
Contract Date: Feb 25, 2026 Contract Value : 23.94 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 9
Maharashtra View Result →
32.
Defence #9920425 AOC
Tender For Special Repair To Bldg No T124 At Sansari Lane Including Guard Post Lpg Store Shed And Provn Of Rain Water Harvesting Collection Near Bldg No P647 Cook House Of Eqpt Bty Tech Sp Regt School Of Arty Under The Aor Of Ge Deolali; 1 Taking down chowkhats or frames (without taking off shutters from the frame) n. exc 1.5 Sqmincl cutting holesand making good reqd shape for hold fast block for new frame complete all as specified and directed. 2 Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm incl cutting holesand making good reqd shape for hold fast block for new frame complete all as specified and directed. 3 S & F for powder coated aluminium ventilator shutters with frame not less than 0.55 Kg/Rm, half bottom portion fixed with 4mm thick glass with fixed type shutter and top half portion lower type with 4mm thick frosted glass and outer side fixed with stainless steel wire mesh, shutters aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, necessary aluminium fittings etc complete all as specified and directed. 4 S & F for Steel rolling shutters 1.25mm thick with ball bearing, as specified including top cover, an choring rod, hasp and staple and one shop coat of primer; erected in position as indi cated, complete: push pull or manual type complete all as specified and directed. 5 S & F forFramed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framedbalusters; walk ways; railings; framework of water tanksand similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed. 6 Demolition of stone slabs and tiles laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc complete all as specified and directed. 7 M&L for Glazed ceramic tilesof size300 mm x 450 mm x 7mm thick (coloured) of superior qualityfixed on vertical surfaces such asskirting/dado etc, set and jointed in neat cement slurry over 10mm thick backing coat in CM (1:4)and pointed in coloured cement to match the colour of tile complete all as specified and directed. 8 M&L for non skidceramic tiles of size 7 to 8mm thick (coloured) (Square/rectangular) size of tile 300mmx300mm, in floors, set & jointed in neatcement slurry and pointed in coloured cement over 15mm thick screed bed in CM (1:6) complete all as specified and directed. 9 M&L for Machine cut kota stone slab flooring18-20 mm thick (size 595 x 595mm) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab inclunding rubbing and polishing complete including screed bed 15mm thick in CM (1:6) complete all as specified and as directed. 10 M&L for Machine cut kota stone slab on steps as inriser/tradein single piece of any size 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab inclunding rubbing and polishing complete including screed bed 15mm thick in CM (1:6) complete all as specified and as directed. 11 M & L 20 mm thick granite (of any type) work( table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and likeincl 10mm thick rendering in CM 1:4, pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite slab , notching and mouldingcomplete all as specified and as directed . 12 S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of plain or corrugated sheeting any gauge thickness including Nainital or similar pattern as in roof covering complete all as specified and as directed. 13 S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of plain or corrugated sheeting any gauge thickness including Nainital or similar pattern as in roof covering complete all as specified and as directed. 14 Dismantling timber scantlings (Purlins/Rafters) any sec and size, in any position complete all as specified and as directed. 15 S & F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified. 16 Taking down cement plaster of any description, any thickness from surfaces of walls/soffits of roof projections & chajjas /ceilings etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified and directed. 17 Demolition of brick work / stone boulders masonry built in cement mortar incl all Quoins , archeas, pillars etc bu exc cluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed. 18 M & L for Brickwork with fly ash Old size bricks, straight or curved on plan exc 6m mean radius, built in in CM 1:6 etc complete all as spd and directed. 19 M & L for 15mm thick rendering in cement mortar 1:4 on fair face of brick walls/ concrete surfaces and finished even and smooth without using extra cement in any position incl scafolding etc, complete all as specified and as directed. 20 M & L for 15mm thick rendering in cement mortar 1:6 on fair face of brick walls/ concrete surfaces & finished even and smooth without using extra cement in any position incl scafolding etc, complete all as specified. 21 M&L preparation of new plastered surface of walls and applying two coats of oil bound distemper over 1.5mm thick wall care putty over one coat of chalk whitening primer complete all as spd and directed. 22 M & L for preparation of new plastered surface of wall/fins/facia/chajjas etc and applying two coat of exterior weather proof 100% anti fungal acrylic smooth emulsion with silicon additives over a coat of exterior primer, exterior weather proof offer anti alge high performance exterior wall finish any colour/ tintcomplete all as specified and directed. Make: Asian (apex ultima), Berger (wather coat), nerolac (excel total). 23 M & L two coat of synthetic enamel paint (finishing coat) over one coat of primer to newsteel surfaces of any description over 10 cm width or girth incl prepration of surfaces complete all as specified. 24 Demolition of cement concrete (unreinforced) in ground floor or in any position and paving not exc. 15 cm thick (below or above ground level) complete all as specified and as directed. 25 M & L for 75 mm thick cement concrete 1:3:6type C2(using 40mm graded stone aggregate) as in plinth protection laid in bays & surfaces finished even and smooth without using extra cement, complete all as specified and as directed. 26 Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified. 27 Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified. 28 S & F 16mm dia CPVC pipes with all fittings SDR 11 & Plain CPVC SDR 11fixedto walls and ceilings with adequate nos of clamps or laid in floor/walls including cutting chases in stone,concrete block or slab wall pinning in making good to facing where ever required to the sufraces for concelled water supply including CPVC & BRASSfittings such as (elbow, tee, socket, reducer, nipple, union, bushing, step over bends, end cap, end plugs, male/female threaded adaptor, flange, tank adaptor) and any other fittings required for fixing of sanitary/plumbing items complete all as specified and as directed. (Note : No extra payment shall be made for cutting chases & CPVC & BRASS fittings) 29 S & F 20mm dia CPVC pipes with all fittings SDR 11 & Plain CPVC SDR 11fixedto walls and ceilings with adequate nos of clamps or laid in floors including cutting chases in stone,concrete block or slab wall pinning in making good to facing where ever required to the sufraces for concelled water supply including CPVC & BRASSfittings such as (elbow, tee, socket, reducer, nipple, union, bushing, step over bends, end cap, end plugs, male/female threaded adaptor, flange, tank adaptor) and any other fittings required for fixing of sanitary/plumbing items complete all as specified and as directed. (Note : No extra payment shall be made for cutting chases & CPVC & BRASS fittings) 30 S&F in repairs 20mm bore CPVC gate valves screwd both ends for CPVC pipescomplete all as specified and directed. 31 S & F Rotational moulded polyethylene water storage tanks 1000 lts capacity, tripple layered (cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia PTMT ball valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed including taking out existing unserviceable overhead tank of any description complete. 32 S & F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers as directed. 33 S&F in rep vitreous china squatting Pan “Orissa” Pattern, of size 580mm x 440mm white with integral foot rests and trap (excluding flushing cistern and flush pipe) including provn of cement concrete bedding complete asfixed complete all as specified. 34 S&F in repair PVC valveless flushing cistern, low level white with inlet ball valve float and handle including brackets complete fixed capacity of flush 10 ltrs complete all as specified and as directed. 35 S & F in repairs PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and as directed. 36 S&F in repair Brass chromium plated shower rose 125mm size complete all as specified and as directed. 37 S&F in repair brass chromium plated Tubular towel rail 20mm dia, D type, 60cm long between flanges. 38 S&F in repair 15mm bore Bib cock chromium plated Make Jaquar continental series or equivalent in Cera, Marc or Parryware complete all as specified. complete all as specified and directed. 39 S & F in repair 15mm bore angular stop cock chromium plated with wall flange of Make Jaquar continental series or equivalent in Cera, Marc or Parryware complete all as specified. 40 S&F in repair stainless steel soap dish, complete all as specified and as directed. 41 Taking down eaves gutters andrainwater pipes (any size orpattern), including all fittings,heads, shoes, bends, swan-necks,etc., including cleaning or refixingor removal to Store (measured overall as fixed along the centre line over fittings and accessories 42 S&F for 110mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors including fixing stac clamps complete all as specified and as directed. 43 S&F PVC (SWR) bend with access door any radius 110mmcomplete all as specified and directed. 44 S & F in repair PVC (SWR) floor trap 75 mm boreplain with grating including jointing with solvent cement and fitting complete all as spd and directed. 45 S&F for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 75mm single rebate comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (Cost of M.S. hold fast/ lugs or SS dash fasteners shall be included in quoted rates).Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made Make : ECHON/Sintex/Rajshree/Navaratan 46 S&F 28-30 mm thick moulded Prelaminatedboth side WPC factory made 100% solid door (conforming as per IS-4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10 mm deep mould on both side with wood grain texture both side with density not less than 600 Kg/cum.Manufactured by an ISO : 9001-2015 certified company. The door should be water proof, termite proof, fireretardant and having screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50N/ mm2, modulus of elasticity 850N /MM2 and resistance to spread of flame of Class A category with property of being termite/ bore proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S. screws, all as per direction of Engineer-in-Charge. (Note : Stainless steel butt hinges and necessary SS screws shall be paid separately) 47 S&F 100 mm long butt hinges stainless steel medium weight complete fixed with full body threaded Star headed counter sunk SS screws all as specified and as directed. 48 S&F 150mm long Aluminium anodizes barrel tower bolts of extruded section complete all as specified and as directed. 49 S&F 150mm size aluminium anodized handle complete all as specified and as directed. 50 M & L for Coloured Machine pressed precast conctete interlocking paver block of any shape and size (Two colour combination) confirming to IS 15658-2006 of 80 mm thick, M-40 Grade with grey cement and pigmentlaid dry in floor/path complete including 30mm thick sand cushioning all as specified and as directed. 51 M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate ) as in sub base or under floor etc complete all as spd and directed. 52 Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for foundation exc on for walls, shafts, manholes not exc 10 Sqm on plan or for laying pipes/cables etc and getting out in soft/loose soil complete all as specified and as directed. 53 Returing filling in incl spreading levelling watering and well ramming in layers not exceeding 25cm in soft or loose soil complete all as specified and as directed. 54 Removing excavatged matereials to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point in soils complete all as specified and as directed. 55 M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and similar work; vertical or to batter complete all as specified and directed. 56 M & L for Formwork to sides of pillars, posts, struts, piers,columns and stanchions square or rectangular rough finished surfaces of concrete laid flat complete all as directed. 57 M & L for mild steel TMT bar 10mm dia and over cut to length,bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 58 M & L for TMT bars 5mm dia upto and including 10mm dia as in stirrups, spacers and binders cut to length,bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 59 M & L for RCC M-25 (Nominal Mix) (20mm graded stone aggregates) in Columns, pillars, piers, posts and struts etc. complete all as specified and directed. 60 M & L for RCC M-25 (Nominal Mix) (20mm graded stone aggregates) in foundations, including rafts, footings, foundation beams; bases for columns etc.complete all as specified and directed. 61 Excavation over area n exc 1.5M deep and getting out in soft/loose soil complete and directed by Engineer-in-Charge. 62 Excavation over areas exc 1.5M deep and nt exc 3.0M deep and getting out in hard/dense soil complete and directed by Engineer-in-Charge. 63 Excavation over areas exc 1.5M deep and nt exc 3.0M deep and getting out in hard/dense soil complete and directed by Engineer-in-Charge. 64 M&L forForming embankments including raising(orlowering)earth,spreading in layers n exc. 30 cm thick; watering,ramming/rolling and finishingto requiredsize, shape,etc., n exc. 1.5 m high from base all as specified and directed by Eng-incharge. 65 M&L for stone masonary walling of random rubble uncoursed ,well bonded, beded and solidly hearted built in CM 1:6 66 M&L for boulder pitching, grouted with cement and sand mortar including boulders all as specified and directed by engr incharge 67 M&L for Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses all as specified and directed by Engr in charge. 68 M&L for Raised pointing to random or polygonal rubble, uncoursed orbrought upto courses with cement mortar (1:4) all as specified and directed by Engr in charge. 69 S&F for 110mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid on wall complete all as specified and as directed. 70 Providing precastce- ment concrete (1:2:4)in bond stone (in retaining walls) win- dow or door cills,lintels,bressumers,steps,quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts,boundary pillars, bed plates, pintle blocks,ancho-rage blocks, bonders (for stone walling). corbels, brackets, etc. (of any section indicated), with plain fair faces, includingchamfers, weatherings, throat- ing etc. and setting in cement mortar(1:4) complete with joints to match all as specified and directed by Engr in charge. 71 M&L for cementconcrete 1:2:4 type B-1, using 20mm graded stone aggregate as in coping, bed blocks, filling of hold fast PCC or similar works including formwork complete all as specified and directed. 72 M&L for brick work with fly ash brick straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed. 73 Formwork to edges of concrete flats, treads, breaks in floors window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide all as specified and directed by Engr -incharge 74 M&L RCC 1:2:4 type B1 ( using 20mm graded crushed stone aggregates) as inBeams, cantilevers, bressummers, lintels over 1.5m span 75 M&L for precast cement concrete 1:2:4 type B1, (using 20mm graded stone aggregates) as in manhole cover slab set in CM (1:6) complete all as specified and directed. 76 M&L RCC M-25 design mix as in Slabs supported on walls beams and columns in floors roofs, landings(using 20mm graded stone aggregates) complete all as specified and directed. 77 M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs landings and similar work not exceeding 200mm thick (Horizontal or slopping) with fair finished curved surfaces 78 M&L for drilling/boring vertical bores with reverse rotary rig are any other suitable method as per latest enginerring technology practice without casing pipe with202mm dia bit to a depth exceeding 30 m and not exc 40m below ground level includiing all necessary work required for boring and filling of pea gravels all round the lowered pipe etc complete all as specified and directed. Note (i) depth of boring shall be measured from of rechargewell. (ii) Pea gravels for filling shall be measered and paid for seperately 79 S&F machine pressed precast concrete interlocking paver block rubber moulded, any shape and size confirming ti IS-15658-2006 of 60mm thickness grey cement and withpigment , M-35 gradeincl30mm thick Sand filling to under interlocking tiles complete all as specified and directed. 80 M&L broken half burntbricks loose filling with aggregates of guage 80 to 150mm in soakage pits soakage well ,rainwater harvesting pits complete 81 M&L for broken stone boulderof gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick,wateredand rammed to a true surface 82 M&L for loose filling with pea gravel of size 1/8 to 3/8 to as in filter bed complete all as specified 83 S & F UPVC(sch-40) slotted pipe 200 mm outer dia including bends and fittings etc placed in bore holes complete all as specified and directed. 84 M & L for uPVCslotted pipe 100 mm outer dia including bends and fittings laid in trenches complete all as specified and directed 85 S&F single pointed air termination, aluminium rod 12 mm dia and 300 mm long incl suport block incl taking down u/s complete all as specified and directed. 86 Supply & fix aluminium strip25 x 3 mm complete duly fixed on porcelain/epoxy insulator with the help of nut, bolt, and washers etc for roof and down conductor above ground (all the joint shall be properly riveted and brazed welded), incl taking down any type strip complete all as specified and directed. 87 Supply and installation of earth continuity conductor or main earthing lead fixed to wall on batten or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 32 x 6mm GI strip any type complete. 88 S&F earth test point terminal block made of gun metal or phosphorous bronze size 75x75x25mm, drilled and screwed including 3 Nos 8mm dia 25mm long hex. Head screw, including factory made test point terminal box, complete with suitable polycaronate box with lacking arrangement all as specified and directed by Engr-in-charge. 89 Supply and lay 40 mm bore GI tubinglight grade, ISI marked, for cable protectionatroad crossing/floor/wall/ on poles or at any indicated situation etc duly sealed at both end after drawing cable including necessary clamps,saddels etc complete all asspecified and as directed. 90 M&L earthing complete with GIelectrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level (with top edge of earthplate not less than 1.50 mtr below normal ground level connected to GI strip 32x6mm as earthing lead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze of sixe 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil incl 40 mm GI tubing light grade and necessary fitting for protection of GI strip incl laying of charcoal dust and common salt PPC (1:2:3) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm MSangle iron frame for cover 40 mm thick (1:2:4) type B20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally PGL funnel with ground wire mesh 20mm dia Med grade GI pipe for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth test incl testing completed all as specified and directed. Note:- GI strip and protecton light grade GI pipe upto 7.5 mtr shall be deemed to be in the rates. 91 M&L for Providing PCC 1:2:4 type B-1 20 mm graded aggregate for GI tubing post for lightening protection complete all as specified and directed. 92 Note: Amount of sch of credit of Rs.40456/-will be deducted from total amount of BOQ.
Contract Date: Feb 25, 2026 Contract Value : 26.05 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 7
Maharashtra View Result →
33.
Defence #9913773 AOC
Tender For Renovation Of Existing Sentry Post, Existing Exit/Entrance Main Gate & Wicket Iron Gate, Damaged Boundary Wall, Raising Height Of Existing Boundary Wall, Construction Of Two Watch Towers Of Milkman Colony And A Pathway Along The Boundary Wall Inside Campus At Ocr Jodhpur Under Ge (A) No. 02; 1 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/dense of soil complete all as specified and directed by Engr-in-charge. 2 Excavating in trenches, n exc 1.5 Mtrwide and n exc 1.5 Mtr in depth; forfoundation, etc. or for shafts, wells,cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 Mtr indepth and getting out in hard & dense soil complete all as specified and directed by Engr-in-charge. 3 Ditto-all as per item no 2 but exc 1.5Mtr and n.exc 3Mtr depth of excavationand getting out in hard & dense soil complete all as specified and directed by Engr-in-charge. 4 M&l for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundations fillings & mass concrete complete all as specified and directed by Engr-in-charge. 5 M&L forproviding RCC M25 Design mix ( using 20 mm graded aggregate) as in foundations, including rafts, footings,foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engr-in-charge. 6 M&L forproviding RCC M25 Design mix( using 20 mm graded aggregate) as inColumns,pillars, piers, posts and strutscomplete all as specified and directed by Engr-in-charge. 7 M&L forproviding RCC M25 Design mix( using 20 mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engr-in-charge. 8 M&L forproviding RCC M25 Design mix( using 20 mm graded aggregate) as in Chajjas etc complete all as specified and directed by Engr-in-charge. 9 M&L forproviding RCC M25 Design mix( using 20 mm graded aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings,balconies, canopies, deck slabs and in shelves and the likecomplete all as specified and directed by Engr-in-charge. 10 Use & waste of Formwork to concrete sides and soffit of concrete foundations, footings, bases of columns, raft and raft beams of foundation , plinth beams and similar work; vertical or to batter for rough finished surfaces complete all as specified and directed by Engr-in-charge. 11 Use & waste of Formwork to sides of square/rectangular or polygonal pillars, posts, struts, piers,columns and stanchions for rough finished surfaces complete all as specified and directed by Engr-in-charge. 12 Use & waste of Formwork to sides and soffits of floor or roof beams, beam , lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished surfaces compleate all as specified and directed by Engr-in-charge. 13 Use & waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces complete all as specified and directed by Engr-in-charge. 14 Use & waste of Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide for rough finished surfaces complete all as specified and directed by Engr-in-charge. 15 M&L for mild steel TMTbars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping forcolumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-charge. 16 M&L for mild steel TMTbars 5mm dia and over upto and including 10mm dia asin stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping forcolumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-charge. 17 M&L for squared rubble walling Jodhpur type brought upto course well bonded, bedded and solidly hearted built in cement mortar (1:6) complete all as specified and directed by Engr-in-charge. 18 Extra over of hammer dressing to face stone with maximum depression on face from straight edge not exc 20mm and dressing face bed and joints as specified to squared rubble walling jodhpur type brought upto cources as directed complete all as specified and directed by Engr-in-charge. 19 Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engr-in-charge. 20 M&L for brick work with Fly ash old size ‘bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6. complete all as specified and directed by Engr-in-charge. 21 M&L for Brickwork with Fly ash old size ‘bricks straight or curved on plan to any radius inhalf brick thick walls built in CM 1:4 complete all as specified and directed by Engr-in-charge. 22 M&L for 40mm thick cement concrete 1:2:4 Type B0(using 12.5 mmgraded stoneaggreagate) as in damp proof coursewith WPC to vertical or horizondal surface including necessary form work complete all as specified and directed by Engr-in-charge. 23 M&L 15mm thick rendering consist of 2 layer , first layer 10mm thick in CM 1:6 and outer layer of 5mm thick in cm 1:4on fair faces of brick or concrete surfacesfinishedeven and fairwith WPC 0.20 lts per bag ofcement used on roof , chhajja complete all as specified and directed by Engr-in-charge. 24 M&L15mm thick rendering in CM 1:6 on fair facesof brick/concrete surface finished even and smooth with out using extra cementcomplete all as specified and directed by Engr-in-charge. 25 M&L 5mm thick renderingin CM 1:3 on ceilingof concrete surface finished even and smooth without using extra cement etc. complete all as specified and directed by Engr-in-charge. 26 M&L15mm thick rendering in CM 1:4 on fair facesof concrete surface finished even and fair complete all as specified and directed by Engr-in-charge. 27 M&L for preparing new plastered surface of wall and applying two coats of weather proof exterior grade emulsion paint over and including a coat of cement based primer, complete all as specified and directed. By Engr-in-charge. 28 M&Lfor preparing newly plastered surfaces of wall and applying two coats of oil bound distemper overa coat of primer including 2mm thick putty to make the surface to be plain and smooth complete all as specified and directed by Engr-in-charge. 29 M&Lfor preparing newly plastered surfaces of walland applying three coats of white wash complete all as specified and directed by Engr-in-charge 30 M&Lfor preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed by Engr-in-charge. 31 Removing excavated material exc. 250m but n.exc 500m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engr-in-charge. 32 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed by Engr-in-charge. 33 M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed by Engr-in-charge. 34 M&L for broken stone Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engr-in-charge. 35 M&Lfor 75 mm thickPCC 1:4:8 type D2 using 40 mm graded stone aggreagateas in sub base of flooring/path/hard standing complete all as specified and directed by Engr-in-charge. 36 M&L for cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth .complete all as specified and directed by Engr-in-charge. 37 M&L for joint free non skid ceramic coloured tiles, of size 600x600x7 to8 mm thick (square/rectangular), in floors etc , set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM (1:6) complete all as specified and as directed by the Engineer -in-charge. 38 Ditto all as per item No 37 but as in skirtingand set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick backing coat in CM (1:6) complete all as specified and as directed by the Engineer -in-charge. 39 M&L for non skid ceramic color tiles of size300x300x7 to8 mm thick ( square / rectangular) as in flooring etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed/ bedding layer in CM (1:6) complete all as specified and as directed by the Engineer -in-charge. 40 M&L for glazed ceramic coloured tilesof size 300x 450x 7 to 8 mm thick on vertical surface such as in dado over 10 mm thick rendering inCM (1:4) complete all as specified and directed by Engr-in-charge. 41 S&F viterous china Pedestral typepattern EWCwhite with P or Strap front or back inlet ( excluding flushing cistern and flush pipe) including PVC Sheet cover and provision of cement concrete bedding and making good surfaces complete all as directed. as specified by Engr-in-charg. 42 S&F PVC low level flushing cistern 10 lts capacity with ball valve float and handle ,syphonic action type including brackets and flush pipe of polythelene of low or high density or PVC 32 mm dia low level flushing cistern fixed in repairs all as specified and directed by Engr-in-charge. 43 S&F vitreous china wash hand basin ,white, flat back, size 550x400 mm including 32mm low density Waste pipe(600mm long)chain and plug and porcelain stopper, brackets including cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed by Engr-in-charge. 44 S&F PVC connection 15mm bore with PTMT nuts and 450 mm long complete all as specified and directed by Engr-in-charge. 45 S&F for tubular towel rail 20 mm dia 600 mm long brass CP including brackets fixedcomplete all as specified and directed by Engr-in-charge. 46 S&F forPVC multipurpose cabinet mirror with front openable door of overall size 350 x 450 mm, complete all as specified and directed by Engr-in-charge. 47 S&Flong body bib taps, 15 mm dia fancy type chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engr-in-charge. 48 S&F 15 mm dia pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated fancy typescrewed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed by Engr-in-charge. 49 S&F for 15 mm stop/angle cock ofchromium plated fancy typecopper alloyscrewed down high pressurefor iron pipe or for unions fixed complete all as specified by Engr-in-charge. 50 S&Fin repairfor Brass CP with long shank and cup (concealed type screwed down, high presure capstan head handle for iron pipe and fixed with wall flange ISI marked complete all as specified and as directed by Engr-in-charge. 51 S&Fforoverhead shower 150x150 mm of ABS body crome plated with gray face plate with arm having swivel joint chromium plated complete all as specified and as directed by Engr-in-charge. 52 S&F forhealth faucet with 1.25m long flexible mild steel chromium plated tube 15 mm dia with wall hook complete all as specified anddirected by Engr-in-charge. 53 S&F chromium plated Brass grating100 mm dia complete all as specified and directed by Engr-in-charge. 54 S&F PVC floor/nahani trap 75 mm dia with grating including jointing to wastepipe fixed in cement concrete 1:2:4 type B1 complete all as specified and directed by Engr-in-charge. 55 S&F rotational moulded polyethylenecylindrical vertical withclosed top water storagetanktriple layered white colour 1000 ltr capacity with connectingnipple, hoisted and fixed in position on new or existingfoudation and making GI tubing inlet or outlet connection complete all as specified anddirected by Engr-in-charge. 56 S&F rotational moulded polyethylenecylindrical vertical withclosed top water storagetanktriple layered white colour 500 ltr capacity with connectingnipple, hoisted and fixed in position on new or existingfoudation and making GI tubing inlet or outlet connection complete all as specified and directed by Engr-in-charge. 57 S&F 20mm outer bore CPVC pipes SDR 11 with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed by Engr-in-charge. 58 S&F 16mm outer bore CPVC pipes SDR 11 with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed by Engr-in-charge. 59 S & F 15 mm bore Galvanized Steel tubes, medium gradefixed to walls and ceilings or laid in floors, concealed or open incl cutting of grooves including taking up or down with connections and fittings complete all as specified and directed by Engr-in-charge. 60 S & F 20 mm bore Galvanized Steel tubes, medium gradefixed to walls and ceilings or laid in floors,concealed or open incl cutting of grooves including taking up or down with connections and fittings complete all as specified and directed by Engr-in-charge. 61 S&F 20 mm dia gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engr-in-charge. 62 S & F 20 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed.Minimum weight2 0 m m - 2 1 0 g m s complete all as specified and directed by Engr-in-charge. 63 S & F 75 mm PVC SWR pipe single socketed in any length with rubber ring joints laid in walls complete all as specified and directed by Engr-in-charge. 64 S &F 75 mm PVC SWR pipe single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed by Engr-in-charge. 65 S &F 110 mm PVC SWR pipe single socketed in any length with rubber ring joints laid in walls complete all as specified and directed by Engr-in-charge. 66 S& F 110 mm PVC SWR pipe single socketed in any length with rubber ring joints laid in trenches or in floors .complete all as specified and directed by Engr-in-charge. 67 S F 75 mm diaPVC (SWR)bendsany radius complete all as specified and directed by Engr-in-charge. 68 S& F 110 mm diaPVC (SWR)bendsany radius complete all as specified and directed by Engr-in-charge. 69 S&F 125/110 mm PVC (SWR) gully trap, setting and jointing with solvent cement complete all as specified and directed by Engr-in-charge. 70 S&FStack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof. complete all as specified and directed by Engr-in-charge for 100mm dia pipe. 71 M&L for MS work as in grills and similar work confirming to Fe 290, gde-E-165 complete all as specified and directed by Engr-in-charge. 72 M&L for MS frame workas in ladder of angle or other section with railing bracers etc conforming to Fe-290 Gde E-165 and fixed complete all as specified and directed by Engr-in-charge. 73 S&F 5.5 mm thick coloured sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed by Engr-in-charge. 74 S & F 5mm thick pin headedglass, ordinary quality and glazing with oil putty in square n.exc 0.5 sq. m in each pane complete all as specified and directed by Engr-in-charge. 75 S & F forStainless steel wire cloth.0.56mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as specified and directed by Engr-in-charge. 76 M&L for25 mm thick Sand stone slabs in plinth protection ofn exc. 2m in length and n.less than750mm wide punched dressed on face and along exposed edges, self faced on other side andover and including 15mm thick screed bed in CM 1:6as in plinth protection , set and pointedincement mortar 1:4 and edges of50 mm thick, finished with using PCC 1:2:4 Type B1complete all as specified and directed by Engr-in-charge. 77 M&L for Green marble 18/20 mm thick in steps, pillars, wndow cills, pillars, window cills, cooking platforms and like laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed by Engr-in-charge. 78 M&L for Machine pressed precast concrete interlocking paver block rubberisedany shape and size with white cement cement andpigment comfirming to IS 658-2006 of60mm thick M-35 grade complete all as specified and directed by Engr-in-charge. 79 M&L sand filling under path as cushioning to interlockingincluding watering and consolidation complete all as specified and directed by Engr-in-charge. 80 M&L for Cement concrete Type B1 1:2:4 (20 mm graded aggregate) as in stops, coping etc including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed by Engr-in-charge. 81 M&L for cement concrete 1:4:8 type D-2 (Nominal mix) using 20 mm graded crushed stone aggregate as in concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 180 mm bore pipes complete all as specified and directed by Engr-in-charge. 82 M&L for DWCPE(SN8) 180mm(OD) /163 (ID)mm bore of pipelaid and jointed on concrete bed 150mm thick , complete including testing etc. all as specified. (Concrete bed shall be measured and paid for separately).complete all as specified and directed by Engr-in-charge. 83 Supply and fixing factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x5 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.00 sqm) comprising of uPVC multi chamberedrame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (stainless steel butt hinges and necessary S S screws, 6 mm Glass or wiremesh incl in this item).Note: For PVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. inepth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 84 Supply and fixing factory made uPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads ofappropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Glass shall be paid separately). Note: For PVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 85 S & F for Factory made double extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 65x100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified & directed. by Engr-in-charge. 86 S & F for Factory made double extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 65x125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). ® Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 87 S&F forfactory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter ( 2,4,6 raised panel design on the front side and back side plain) of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed by Engr-in-charge.Note: stainless steel (100mm butt hinges- 03, 150mm tower bolt-02, 300mm Sliding door bolt - 01, 150mm handle -02 and necessary S.S screws shall be including) 88 S& F for30mm thick factory made solid WPC (Wood plastic composit) moulded gauged door shutter with wire mesh in any number of division with brown wood grain texture, including stainless steel wire shall mesh be fixed with 15x15 Square tube in side rails with screwing 8x28 heat metal zink coated screws can be remove or fie again of the shall be as per manufacture instruction complete all as specified and directed by Engr-in-charge.Note: stainless steel (100mm butt hinges- 03, 150mm tower bolt-02, 300mm Sliding door bolt - 01, 150mm handle -02 and necessary S.S screws shall be including) 89 S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm thick prelaminatedcolour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed by Engr-in-charge. 90 S &F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm prelaminatedcolour PVC sheet on back face with wood free EPS core including fixing in frame at site as per specification & drawing complete all as specified and directed by Engr-in-charge. 91 M&L Rendering 15mm thick cement mortar 1:4 shall be provided mixed with WPC @3% by weight of cement at green concrete complete all as specified and directed by Engr-in-charge.Note: WPC shall be measured and paid separately 92 Supply only Integral waterproofing compound complete all as specified & as directed by Engineer-in-Charge 93 M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabriclaid on primed surface of blown Bitumen of 1.2Kg per Sqm by torchingapplication and over including a coat of approved bituminous primer @ 0.40 liter per Sqmcomplete all as specified & directed by Engr-in-charge. 94 M&L for PCC 1:2:4 Type B-1 (using 20mm graded stone aggregate ) average 40mm thick ,finishingthe top concretesurface even andsmooth without using extra cementover APP membrane surfaceon roof / terrace.complete all as specified and directed by Engr-in-charge. 95 M&L for Provn of Soakage wells exc,in ordinary soil,foundation in PCC 1:3:6 ,wells of honey combed and solid in M-25 concrete,including intercepting chamber,screen chamber Brick work in CM,RCC cover slab in M-25/ Brickmasonary/Filling with brick bats ,complete of size (1.2 m dia x 3.0 M deep) complete all as specified and directed by Engr-in-charge. 96 Surface dressing n exc 30cm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified & directed by Engr-in-charge. 97 Removing excavated material (soil)n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point. Complete all as specified and directed by Engr-in-charge. 98 M&L for squared rubble stone wallingJodhpur type,regular coursed,well bonded, bedded and solidly hearted,built in CM(1:6) complete all as specified and directed by Engr-in-charge. 99 Extra over stone masonry for hammer dressing to facestones with maximum depression on face from a straight edge held against the dressed surfaces not exc 20mm and dressing face beds and joints as specified to squared rubble walling, Jodhpur type, regular coursed complete all as specified and directed by Engr-in-charge. 100 M & L for keyed pointing over square rubble stone walling, regular coursed jodhpur type built in CM (1:3). Complete all as specified and directed by Engr-in-charge. 101 M&L for work as in post and struts in fencing including cutting top to shape as directed railing holes notching for wire etc and similar work conforming to Fe-410-0 or Fe -310-0 comlete all as specified and directed by Engr-in-charge. 102 M&L for Mild steel screw bolts 11 to 15mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed by Engr-in-charge. 103 Supply only for Chain link MS galvanized fencing, 50mm aperture size complete all as specified and directed by Engr-in-charge.Note:- A BOO shall be detailed by GE to as certain the per sqm weight of chain link fencing. 104 Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed by engr-in-charge. 105 M&L for Mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-charge. 106 M&L for preparing new steel surfaces of any description exceeding10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge. 107 S & F galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts incl. securing or tying at crossing with and provision of galvanised mild steel wwire staples or steel pins etc complete all as specified and directed by Engr-in-charge. 108 S&F of GI concertina coil of dia 600 mm and shall be fixed complete all as specified and directed by Engr-in-charge. 109 M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed by Engr-in-charge. 110 M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed by Engr-in-charge. 111 Material and labour for point wiring (Modular) complete light/exhaust fancontrolled by one switch one way with 1.5 sq mm single core multi stranded copper conductor PVC FRLS insulated unsheathed 1100 Volt grade cable in and includingPVC FRLS CONCEALED CONDUIT PIPE (ISI Marked) of 20/25 mm bore with all accessories including new pressed steel terminal boxes (sunk in wall ) with 3.00 mm thick plastic laminated sheet top cover or PVC FRLS board including PVC FRLS top cover (suitable for modular switch & sockets etc .) with 1.50 sq mm insulated unsheathed PVC FRLS multistranded covered copper conductor for common earth and connecting to earth dolly and making good disturbed surface of wall incl matching the colour of wall/ceiling with extisting wall/ceiling colour complete all as specified and directed by engineer-in-charge. 112 All as per srl item no. 111 here-in-before but for one socket outlet 3 pin, 5 Amps on independent board complete all as specified and directed by Engr-in-charge. 113 All as per srl item no. 111 here-in-before but for one socket outlet 3 pin, 5 Amps on same board complete all as specified and directed by Engr-in-charge. 114 All as per srl item No 111here-in-before but with 4 sq mmFRLS copper wire with 4 Sqmm FRLS copper earth wire for 3 pin socket 15 amp independent or other suitable pointcomplete all as specified and directed by Engr-in-Charge 115 All as per srl item no. 111 here-in-before but for one light point controlled by two 2-way switches complete all as specified and directed by Engr-in-charge. 116 Material & Labour Modular switch 6A one way complete all as specified and directed by engineer-in-charge. 117 S & FModular Socket, 6 A ,5 Pin,2 module size complete all as specified and directed by Engr-in-charge. 118 S & FModularswitch1way 16 A , 1module size complete all as specified and directed by Engr-in-charge. 119 S & FModularSocket , 6 A , 5 Pin , 2module size complete all as specified and directed by Engr-in-charge. 120 S & FModular Switch two way 6A , 1 module size complete all as specified and directed by Engr-in-charge. 121 S&F of Modular type regulator 2 module A/C 240 Volts complete all as specified and directed by Engr-in-charge.. 122 Supply and fixingCeiling rose on PVC FRLS board size 65 X 50 mm three terminal complete all as specified and directed by engineer-in-charge. 123 Supply and fixing LED light fitting mirror type with high output difffuser 2 feet ,10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by engineer-in-charge. 124 S&F LED light fitting 1 X 20 watt (4 feet),Batten Light, a slim design with internal driver, complete with all accessories and making necessary electric connection from ceiling rose to fitting terminal,complete all as specified and directed by engineer-in-charge. 125 S&F LED bulb of 9 /10 watt,6500K including PVC holder complete all as specified anddirected by Engineer-in-charge. 126 Supply and fixing LED street light fitting not less than 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-in-charge. Note:-The cost supplying and fixingiron bracket 32 mm bore with necessary nut bols ,clamp etcis included in quoted rate. 127 Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mmcomplete all as specified and directed by engineer-in-charge. 128 Supply and fixing ceiling fans complete with blades, canopy,down rods upto 2 feet, including all accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed by engineer-in-charge. 129 Supply & Fixing Distribution Board, double Door, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, SPN 4 way (Concealed flush to wall), 240 volts with bus bar rating 200 Amps, dust and vermin proof, suitable for incorporation of MCB’s and isolators etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed by Engr-in-charge.Note : 1.Blank plates will be included on the quoted rates.2. All wires to be properly connected with copper lugs.3.MCB will be measured and paid separately. 130 Supply and fixing240V, 10 KA B curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioningcomplete all as specified and directed by engineer-in-charge. 131 Supply and fixing MCB SPN 32 Amp, C Curve 240 volts. complete all as specified and directed by engineer-in-charge. 132 M&L for earthing with galvanized steel earth plate electrode of size 600 x 600 x 6 mm buried directly in ground earth pit not less than 2.25 mtr below of normal ground level with top edge of earth plate should not less than 1.5 mtr below normal ground level and connected to galvanized iron earth lead wire of size 4 mm dia by means of bolts, nuts, washers of galvanized iron or steel all as shown in electrical plate No.3 of MES SSR Part I connecting to earthing test point on completion with and including 15 mm bore GI light grade protection pipe (7.5 mtr long) for earth lead GI lead wire 4mm dia (7.5 mtr long), PCC pit with cover in PCC 1:2:4 type B-1 reinforced with 8 mm dia tor bars @ 80mm C/C, 20mm dia medium grade watering pipe with funnel, wire mesh, common salt, charcoal, necessary excavation and earth work, complete all as specified and directed by engineer-in-charge. 133 Supply and fix desert cooler ,electric driven (single phase ),having nominal air flow capacity of 5000 Cum per hour (or nearest size ) steel body complete all as specified and directed by engineer-in-charge. 134 M&L for wall mounting stand for desert cooler made out of MS angle iron of size 40 mm x40 mm x6 mm thick suitable for nominal size of desert cooler including making good for disturbed surface ,welding works ,duly paint of one coat of red oxide primer and two coats of synthetic enamel paint all as shown on drawing No CEJZ/WD/98/TD-15/2017 sheet 1/1 complete all as specified and directed by engineer-in-charge. 135 Supply & laying steel Tubing galvanized medium grade (ISI Marked) 25 mmbore and tube fittings ISI marked laid in trenches /in road/on walls/in open including cutting existing pipeline for insertion of suitabe size tee for connectionetc allas specified and directed by Engineer-in-charge. 136 Supply & FixingGlob or Gate valve 25 mm bore, gun metal with iron wheel head, screwed both ends for iron pipe complete all as specified and directed by Engineer-in-charge. 137 Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 corecomplete all as specified and directed by engineer-in-charge. 138 M&L for Cutting of road/hardstanding not more than 30 cm deep 45 cm widefor crossing of water pipe line in trenches and making the surface good with PCC(1:2:4) type B-1 using 20 mm graded aggregate complete in all respect as specified and directed by engineer-in-charge. 139 M&L Sand cushioning to undergound cable with using tibba sand and gently punning for cushioning to cable complete all as specified and as directed by Engineer-in-charge.Note: For the purpose of payment only punned thickness will be measured. 140 Supply & laying unreinforced precast concrete cable cover , Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified & directed by Engineer-in-charge. 141 Supply & Laying steel tubing light grade galvanised 32 mm bore with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by engineer-in-charge.
Contract Date: Mar 30, 2026 Contract Value : 72.25 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Contract Date: Ref. Documents Contract Value : 24,150
Statutory Bodies & Commissions/Committees No of Bidders 3
Madhya Pradesh View Result →
36.
Public Administrative Department #9851070 Technical Bid
Regarding The Supply Of Necessary Disaster Management Materials, Tools And Chemicals To The Fire Department Of Ambernath Municipal Council.-1 life jacket 2 life ring guard 3 Nylon Rope (1/2 Inch/ 04 Bundles) 4 Heavy Duty Chargeable Torch 5 Portable Fire Pump Fire Fly / Integral Safety Floating Pump (fire Fly make 450 LPM Petrol diven) 6 Bridging Apparatus Set (Dragger make, light weight 1800 Ltr. Capacity, SCBA Scott make sigma 2 type 2 with extra cylinder/ SPASCIANI make with 20 mtr extension hose) 7 Patayache Koyate 8 gal 9 Lifting bag set LPT make Lysikilen swedm made 10 steel cutter TSA 230 battery operated 11 Tikava Dandyasah (Standard Company) 12 Electric / Petrol Wood Cutter Machine Company Sthil 381 Make 18 Inch Blade with 3 extra Chains 13 electric Wood Cutter Machine-Sharpex Company 18-inch blade 14 mini hydraulic rescue kit integral make 15 coyote of the best type (see sample) 16 Firex (see sample) 17 Badli (Red Coloured) 18 Industrial gas monitor GFG germany make senson O2, H2S, CO, LEL 19 tent-12x12 saijcha 20 jumping set size-10x10 integral make 21 Hose Wrap Standard Company 22 15 m. Long Rubber Hosepipe Male-Female Coupling with ISI Certified 23 AquaJet HandControl Nozzle 24 x Regular nozzles 25 short branch pipe 26 Foam Compound Fire Chem in Plastic Can AFFF Is-4989 27 Foambunch FB-05 Standard Company 28 Foambunch FB-10 Standard Company 29 revolving nozzle 30 picac curtain nozzle 31 4 Inch Rubber Suction Hose IS Male Female Coupling Co 32 Safety Shoe- jeevan make, style 1111 Delux Toe, Steel Toe Is 1126, Oil Acid Resistance, Chemical Resistant, Heat Resistant Antiskid with Nitril sole 33 Full Body Harness : Is 3521-1999 Polyester Nylon Webbing for High Breaking Strength 34 DCP Powder type fire extinguisher (stored Pressure) 4kg. Cap safety first make/ intime make 35 ABC type fire extinguisher 4kg. Cap :- Stored pressure UL Approved Safety first make/ intime make 36 Clean Agent Type fire extinguisher 4kg. Cap :- Stored pressure UL Approved HFC 236 TA, filled WT. 7.1 kg design CE/ EN3/ 15683 Safety first Make/ intime make 37 Mechanical foam type 9kg. Cap: Catridge type foam AFFF, CE/EN3/15683, Safety first make/intime make 38 Carbon dioxide type 4.5 kg Cap: Filling weight 16.5 kg, CE/EN3/15683, Safety first make/intime make 39 Dragon Led Search Light 40 Hook Ladder 13 ft 4 in. Simplex Make 41 Rubber Hand Gloves (full size) 6 Nos 42 Shockproof Hand Gloves 43 Waterproof Hand Gloves 44 Safety Face Mask: 6 Nos: Gas, Smoke, Fume, Smoke, ISI Mark 45 Safety Goggles: For eye protection from fumes and smoke, ISI Mark 46 Snake Tongs: ISI Mark 47 Refilling Fire Extinguishers: 1. ABC 5 kg 48 Refilling Fire Extinguishers Do 2. ABC 2 kg 49 Refilling fire extinguishers 3. DCp 5 kg Refilling 50 fire extinguishers 4. Foam Type 9 Ltd. 51 Refilling fire extinguishers 5. Co2 Type 4 kg 52 Refilling of fire extinguishers 6. WCo2 Type 9 Ltd. 53 Refilling fire extinguishers 7. DCP type 50 kg 54 Refilling fire extinguishers 8. Co2 type 33.5 kg 55 Rubber Inflatable Boat 8 person Cap integral make (with 8 HP engine Yamaha/ Suzuki engine) 56 Rubber Dinghi 2 person Cap integral make 57 Bolt Culter battery operated 58 Door breaker 2 no 59 Tree pruner telescopic STHIL 381 with extra chain 60 Trolley mounted Air Line B. A set 61 Floating pump 900 LPM integral make 62 Victim location search camera integral make 63 Air blower petrol drivel integral make 64 smoke extractor petrol integral make 65 concrete chain saw STIHL GS461 66 Head lamp Zoom type 67 Demolition hammer Makita make 68 portable generator 69 helmet vision voyager and hoods 70 Life Jacket (G-Type) 71 Manila Rope (1/2, 3/4, 1, 2 inches) 72 safety harness belt 73 hydraulic door opener 74 hydraulic metal cutter cum spreader 75 floatic stretcher 76 Folding Ladder (Telescopic Aluminum Ladder) 15 m. lambeche 77 Rope Ladder 24 m long 78 AFFF Foam Compound ISI Mark 1000 Ltr. 79 ground monitor 80 Motorola company pursh to talk over cellular GSM 81 motorolla handset TLK 100 82 base station 83 fire fighting suit - Ce Certified As per EN standard *Outer layer made out of inherent flame retardant fabricks 602. inner layer of moisture barrier and thermal barrier *Suit Consist :- jacket trouser balaclava hood fireman helmet gloves and boots storage bag *material at suits :- Nomex (certificale should be provided) * reflective tape smtested to ENGTI
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 1
Maharashtra View Result →
37.
Defence #9843690 AOC
Tender For Completion Of Incomplete Work Of Provision Of Gymnasiums (Cl Ii) At Grrc, Lansdowne.; 1 M&L for 100 mm thick PCC (1:4:8) type D2, (Using 40 mm graded stone agg) as in sub base/sub base of floorcomplete all as specified and directed. 2 M&L for moorum / red bajri filling in, floor or pavings, laid in layers not exceeding 15cm thick, spread, levelled and rammed including watering complete all as specified and directed. 3 M&L for modular brick work with FLYASH bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed. 4 M&L for brick work with SUB CLASS B old sizebricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed. 5 M&L for brick work with SUB CLASS B old size bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed. 6 M&L for 20 mm thick granite slab as approved by the GE (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms, in CM (1:4) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15 mm thick screed bed in CM 1:4 complete all as specified and directed. 7 M&L for 10 mm thick plastering on fair faces of bricksurface in CM (1:4) surface finished even and fair complete all as specified and directed. 8 M&L for 20 mm thick granite slab as approved by the GE (table rubbed and polished) inwall lining (Veneering to wall) in12 mm thickin CM (1:3) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. 9 M&L for 10 mm thick plastering on fair faces of bricksurface in CM (1:6) surface finished even and fair complete all as specified and directed. 10 M&L for preparation of new plastered surfaces of walland chalk whitening and applying two coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturers specificationover a coat of primer of approved make complete all as specified. 11 M&L Providing Granite slab edge moulding to 20mm thick stone of counters vanities ,cooking plateform,step etc.including machine polishing to edge to give high gloss finish etc. complete all as specified. 12 Returning, filling in any type of soil including spreading, levelling, watering and well ramming in layers not exc 25 cm.complete all as specified and directed. 13 M&L for PCC (1:4:8) Type D2 (Using 40 mm gradedstone aggre-gate) 200 mm thickas in floor/paving complete all as specified and directed. 14 M & L 20 to 25mm thick Kota Stone (Mirror Polished) with marble strip all as specified and as directed over 20mm thick screed bed in CM 1:6 complete all as specified and directed. 15 M & L 20 to 25 mm thick Kota Stone (Mirror Polished) 100 mmwidth as in skirting over 10 mm thick cement mortar 1:4complete all as specified and directed. 16 S & F Rubber tile for floor thickness not less than 25 mm thick(tough rubber flooring made upto 40% black recycled rubber & 20% colour EPDM(Ethlyene propylene-Diene-monomer rubber granules & adhesive with V-groove,interlocking & paper cut as directed by EIC plane rubber matting shall have a checker plat surface pattern & a flat revers side. The non directional checker plat patterns gives this matting a non slip surface that is still easy to mop/clean of desired colour.Adhesive -SR 505 or SR 998 as per manufacturers instruction or styrene butadiene copolymer (SBX) latex synthetic rubber adhesive. complete all as specified and as directed. 17 S & F Rubber tile for wall cladding not less than 15 mm thick(tough rubber made upto 40% black recycled rubber & 20% colour EPDM(Ethlyene propylene-Diene-monomer rubber granules & adhesive with V-groove,interlocking & paper cut as directed by EIC plane rubber matting shall have a checker plat surface pattern & a flat revers side. The non directional checker plat patterns gives this matting a non slip surface that is still easy to mop/clean of desired colour.Adhesive -SR 505 or SR 998 as per manufacturers instruction or styrene butadiene copolymer (SBX) latex synthetic rubber adhesive. complete all as specified and as directed. 18 Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed inany mortar and removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. 19 M&L for granitetiles 20mm thick machine cut as approved by GE, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over 20 mm thick screed bed (1:6) complete all as specified and as directed. 20 Taking down cement plaster on brick or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water and removing unseviceable materials out side MoD land complete all as specified and as directed. 21 M&L for 20mm thick Granitetiles machine cut as approved by GE, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing including 10 mm thich rendering (1:4) complete 22 M&L for hard core of broken boulders/stone of gauge n exc. 63 mm, deposited, spreading, leveling watering and well ramming to true surface in layers not exceeding 15 cm thick each layer complete all as specified and directed. 23 M&L for PCC (1:3:6) type C-1, using 20 mm graded stone aggregate as in surface channel and drainetc complete all as specified and directed. 24 M&L for extra for forming fair finished drain, or channel, 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred, stopped ends, complete all as specified and directed. 25 Mirror polishing on marble/ granite/Kota stone/ stone work where everrequired to give high gloss finishcomplete all as specified and directed. 26 Excavating in trenches nexc 1.5 m width and nexc 1.5 m in depth for foundation or for shafts, well cesspits, manholes etc / for laying of cable/ pipe etc nexc 10 sqm on plan and nexc 1.5 m in depth and getting out in soft/disintegrated rock complete all as specified and directed. 27 M&L for PCC (1:4:8 Type D2 (using 40 mm graded stone aggre-gate) as in foundations, filling and mass-concrete complete all as specified and directed. 28 M&L for 15mm thick plastering on brick or concrete surfaces in CM (1:6) surface finished even and smooth without using extra cement complete all as specified and directed. 29 M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. 30 M&L for 100 mm thick PCC (1:2:4) type B2, (using 40 mm graded stone agg) as in sub base of floor complete all as specified and directed. 31 M&L for preparation of newly plastered surface of external wall all as prescribed by manufacturer of paint and applying two coats of exterior anti fungal acrylic emulsion paint of make as approved by GEover one coat of primer complete all as directed. 32 M&L forstainlesssteel (Grade 304) railing made of hollow tubes,channels, plates etc., including welding, grinding,buffing, polishing and making curvature (where everrequired) and fitting the same with necessarystainless steel nuts and bolts complete, includingfixing the railing with necessary accessories &stainless steel dash fasteners, stainless steel boltsetc., of required size, on the top of floor orthe side of waist slab with suitable arrangement complete all as specified and directed. 33 M&L Plain, Aluminiumsheeting,Alloy 31000 H4in ridges, hips, valleygutter, drip and straightflashing (length andgirth as fixed) with powder coating of any colour (thickness of powder coating not less than 50 micron complete all as specified and directed. 34 M&L for pre-formed filler board 25 mm thick for crumple joints complete all as specified and directed. 35 M&L for mild steel screw bolts (machine made) dia of neck length 5 to 10mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, nexc 5cm long complete all as specified and directed. 36 M&L APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application over 15 mm thick cement screedbed (1:4) complete all as specified and directed. 37 S& F 1.25 mm Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer;gear operated type with bevel gear box and crank handle erected in position as indicated including MS Spring for rolling shutter, size of spring 300mm long inner dia not less than 65mm and MS wire 6mm dia complete all as specified and as directed. 38 Supply only Ball bearing for rolling shutters complete all as specified and directed. 39 M&L for twocoats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface over 10cm width or grith complete all as specified and directed. 40 M&L for cutting holes into or through brick walls built in cement mortar and making good in cement mortar (1:3) or PCC (1:2:4) type B1 to match with existing surfaceof following superficial area complete all as specified and as directed :- 41 Superficial area exc 150 sqcm but not exc 400 sqcm 42 M&L bands, straps, supports or stays for rainwater (stack clamp), ventilating pipes, including bolts, if required, hooks (stays), heavy for large gates, hooks and pintle hinges large hasps and staples, hand made sliding bolts, clamps, hold fasts, wall ties, hooksforhanging fans plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts two way and three ways straps, plate washers and similar articles conforming to Fe-290(Gde-E-165) complete all as specified and directed. 43 S&F Powder Coated ofcolour as approved by GE/AGE(I)(minimum thickness of powder coating 50 micron), aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed. 44 S&F Powder coated ofcolour as approved by GE/AGE(I) (minimum thickness of powder coating 50 micron), aluminium door shutters, aluminium section weighing 0.55kg/m incl necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges,anodised aluminium snap beading, screws etc. complete all as specified and directed. 45 S&F Powder coated ofcolour as approved by GE/AGE(I) (minimum thickness of powder coating 50 micron) aluminium window and ventilator shutters, side hung without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed. 46 S&F Powder coated of colour as approved by GE/AGE(I) (minimum thickness of powder coating 50 micron) aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed. 47 S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty/ wooden/ PVC/ aluminium beading, in square n. exc 0.5 sqm in each pane complete all as specified and as directed. 48 S&F 5.5 mm thick sheet glass, ordinary quality and glazing with oil putty/ wooden or aluminium or PVC beads in square in each pane of following size complete all as specified and as directed :- 49 Exc 0.5 sqm in each pane 50 S&F 2nd class hardwood ( sal ) Plain, solid, straight, chowkats & frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. 51 S&F 35mm thick factory made plain framed, panelled door shutters (two panel) of IInd class hard wood rail and styles with lock rail and panel of 9 mm BWP commercial ply. The size of rail and style as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified. 52 S&F extruded aluminium alloy handles, fabricated type, anodised (ISI marked) of following size complete all as directed and specified:- 53 150 mm long 54 S&F anodised aluminium barrel tower bolts (ISI marked) of extruded section of following size complete all as directed and specified:- 55 150 mm long 56 S&F anodised aluminium sliding door bolt (ISI marked) with hasp, staple ( bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of following size complete all as specified and directed:- 57 300mm long 58 S&F floor doorstopper (ISI Marked) of aluminium alloy body andtongue anodised, with hard drawn steel spring, fixed in floor of following size complete all as specified and directed :- 59 140mm long (overall length of cover plate) 60 S&F MS butt hinge, medium weight, cold rolled and fixed of following size complete all as specified and directed:- 61 100 mm long 62 M&L for twocoats of synthetic enamel paint over a coat of pink primer including preparation of new wood or wooden base surface over 10cm width or grith complete all as specified and directed. 63 S&F solid PVC door frame of size 50mm x 47 mm made out of 5 mm plain colour PVC sheet, reinforced with MS square tube, fixing in same opening complete as all as specified and directed. 64 S&F factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top, bottom and side rails, MS frame shall be covered with heat molded plain colour PVC “C” channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail & bottom rail on either side and as gap insert for top rail and bottom rail paneling of plain colour PVC sheet to be fixed in the MS frame welded /sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement and fixing in the frame at site complete all as specified and directed. 65 S&F 125 mm long anodised aluminium barrel tower bolts (ISI marked) of extruded sectioncomplete all as directed and specified 66 S&F vitreous china urinal half stall type urinal white complete including providing and fixing plugs bedding urinal against wall in CM 1:2 securing urinal to plugs with & including 60 mm brass screws pointing around urinal back in cement fixing automatic flushing cistern with brackets flush pipe grating and union for discharge pipe and urinal spreader complete all as specified and directed. 67 S&F 5mm thick bevelled edge best quality looking mirror of size 600x450 mm with 30mm PVC beading all around the glass, mounted over 3mm thick PVC sheet or 6mm thick AC bldg board, complete all as specified and directed. 68 S & Fvitreous china wash basin white (oval shaped under counter) of size 550 x 400mm including 32mm brass CP waste coupling complete all as specified and as directed . 69 S&FPVC valveless, syphonic action type low level flushing cistern white with inlet ball valve, float and handle including brackets, 10 ltr capacity complete with flush pipe(Long bend) 32mm dia of make as approvrd by GE complete all as specified & directed. 70 S&F vitreous china wash down water closet pan (pedestal pattern), white, with and including plastic water closet seat, white, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device, ( excluding fixing bolts, flushing cistern and flush pipe), including connection to drain (or outgoing pipe) and to flushing pipe, anti -syphonage pipe, etc., completeall as specified and directed. 71 S&Ftoilet paper holder of brass, chromium plated, fixed to walls with chromium plated (CP) brass screws complete all as specified and directed. 72 S&F Liquid soap container of PTMT fixed withand including Chromium plated brassscrews and wooden/plastic cleats. (Minimum weight 105gms) completeall as specified and directed. 73 S&F towel rail 600mm long of PTMT fixed with and including CP brass screws and wooden cleats having min weight 190 gms complete all as specified and directed. 74 S&F rotational moulded polyethylene water storage tank, white in colour triple layer construction, ISI mark (cylindrical vertical with closed top) hoisted and fixed in position with and including 20 mm dia Ball valves highpressure of PTMTwithepoxy coatedAluminiumrod&highdensity plastic ballscrewed for iron pipeand fixed.(Minimumweight 15mm-142gms/ 20mm-210gms./ 25mm-455gms/ 40mm- 690 gms),20 mm GI pipe medium grade washout pipe 450 mm long with plug and 20 mm dia GI pipe medium grade overflow pipe 600 mm long with fittings, of following capacity of tank completeall as specified and as directed:- 75 Capacity 1000 Ltrs 76 S&Fof hat pegs, aluminium solid body, 125mm to 175 mm complete all as specified and directed. 77 Returning, filling in ,soft/ disintegrated rock including spreading, levelling, watering and well ramming in layers not exc 25 cm.complete all as specified and directed. 78 Removal of excavated materialto a distance nexc. 50 Mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. 79 Removal of surplus soft/disintegrated rocks to a distance nexc. 50 Mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. 80 Removal of surplus soil to a distance exc. 250 Mtr nexc. 500 Mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. 81 Spreading and levelling in layers n exc 25 cm thick and well ramming including watering as required complete all as spd 82 M&L concrete bed to drain pipes in PCC (1:4:8) type D2 (using 40mm graded stone aggregate) including packing under and haunching against the sides of pipes after they are laid on slope and tested for 150 mmbore sewer pipe line complete all as specified and directed. 83 M&L for 15mm thick plastering on fair faces of brick wall in two layers, Ist layer 10mm thick CM (1:6), and IInd layer 5mm thick CM (1:4), surface finished even and fair mixed withWPC (liquid type) as per manufacturer instruction complete all as specified and directed.Note :- WPC (Liquid type) shall be measured and paid separately as supply only. 84 Supply only WPC integral water proofing compound (Liquid type) complete all as specified and directed. 85 M&L for precast RCC (1:2:4) type B1, (using 20mm graded stone aggregates) as in cover slab (for manholes) and set in CM (1:4) including necessary fair finish formwork complete all as specified and directed. 86 M&L for mild steel TMT bars as in reinforcement, 10mm dia and over cut to length, bent to shape required including cranking, bending hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 87 S&F cast iron (Spun pipe) soil, waste and vent pipes in any length with or without ears, with cement joints laid in trenches or in floor for following bore of pipes complete all as specified and directed:- 88 100mm bore (spun pipe) 89 M & L for PCC type C2 (1:3:6) (using 40mm graded stone agg ) as in surface channel or drain or benching in manhole complete incl. necessary form work all as specified and directed. 90 S& F powder coated mild steel Personel locker unit of size 1140x450x380mm of size and thickness of 0.8mm including lebel holder,HDPE plastic handle, and 04 Nos levelling screws/stands with complete all as specified and directed. 91 S&F harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed. 92 S & F Brass knobs 35-40mm dia complete specified and directed. 93 M&L for RCC (design mix) M-25 (using 20mm graded stone aggregates) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, and in shelves complete all as specified and directed. 94 M&L Formwork to edges of concreteflats, treads, breaks in floors,window cills, concrete rail ings, openings in concretewalls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similarwork exc 10cm but n exc 20cm widecomplete all as specified and directed. 95 M&L for formworkfor rough finish to soffits of suspended slabs such as roof slabs, floor slabs, landing slab and similar work, not exceeding 200mm thick complete all as specified and directed. 96 M&L for mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming complete and all as specified and directed. 97 M&L for 19 mm thick prelaminated particle board, interior grade, ISI marked, pre laminated one side with decorative choice lamination and other side balancing white laminationsuitable fixed with screws to timber frame workcomplete all as specified and as directed. 98 M&L for 10 mm thick plastering on other than fair faces of bricksurface in CM (1:6) surface finished even and smooth without using extra cement complete all as specified and directed. 99 S&F continuous (piano) brass hinges, width of flaps (when open) 30mm complete all as specified and directed. 100 S&F 100mm Hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screwscomplete all as specified and directed. . 101 M&L for preparing old decorated plastered or unplastered surfaces of wall, pillasters, cornices etc and applying one coat of oil emulsion distemper complete all as specified and as directed. 102 M&L for preparing old decorated plastered or unplastered surfaces of wall, pillasters, cornices etc and applying one coat of plastic emulsion distemper complete all as specified and as directed. 103 M&L for preparing newly plastered surfaces of wall and applying/ finishing walls with Acrylic Smooth exterior paint of required shade with Twocoat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) as per manufacturer instruction complete all as specified and directed. 104 S&F Pre-painted galvalume aluminum zinc coated GI based corrugated steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa, AZ-150 as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. 105 S&F 0.63mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 fixed with L-type or J-type or cranked hook bolts in roof, wall etc complete all as specified and as directed. 106 S & F Aluminium section frame work in ACP Cladding complete all as specified and as directed 107 S&F rolled mild steel section for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W(Gde-E-250) quality-Acomplete all as specified and as directed.Note : The rates quoted allow for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete. 108 S & F Plates (Plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and as directed. 109 Erection Fixing only (Retrieved Material will be reused) of roof trusses (framed), trussed, purlins, and fastenings and heavy framing(Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Note : Erection fixing with old section and making the surface smooth as per its original 110 Erection Fixing only (Retrieved Material will be reused) Plates (Plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and as directed. Note : Erection fixing with old section and making the surface smooth as per its original 111 M & L preperation of old steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified 112 S & Fin Repair of20-22mm dia of neck MS Screw bolts(Machine made ) with hexagonal or square heads at one end and screwed at other end or both end, and screwed end to be fitted with washer and one hexagonal or square exc 30cm long etc complete all as specified anddirected. 113 M&L for RCC (design mix) M-25 (using 20mm graded stone aggregates) as in columns, pillars, piers, posts and struts complete all as specified and directed. 114 M&L for RCC (design mix) M-25 (using 20mm graded stone aggregates) as in Chajjas complete all as specified and directed. 115 M&L for RCC (design mix) M-25 (using 20mm graded stone aggregates) as in floor/ roof beam, cantilevers, lintel over 1.5m span complete all as specified and directed. 116 M&L for formwork for rough finish to sides of pillars, posts, struts, piers, columns and stanchionscomplete all as specified and directed. 117 M&L for formwork for rough finish to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed. 118 M&L for formwork for rough finish to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etccomplete all as specified and directed. 119 M&L for mild steel TMT bars 5 to 10mm dia bars as in stirrups cut to length, bent to shape required including cranking, bending hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 120 M & L for preperation of newly plastered surface of internal wall by application of 1mm thick wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper over a coat of primer using roller all as specified and prescribed by manufacture of paint and as specified and directed. 121 M&L of water proofing treatment to non-accessibleroof slabwith APP based modified polymeric membrane as per manufacturer’s instructionswith following course of description below :- (a)Applying a priming coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m, till the surface is properly impregnated.(b) Providing APP based 5 layer polymeric membrane minimum weighing 3 .0Kg/ Sqm and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturers instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer(c) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membranceNote : 1. The work of water proofing treatment shall be got executed through authorised applicator of the manufacturer only and 10 year company back warranty to be submitted by contractor 2. The work is required to be carried out at non-accessibleroof slab for double storeyed.The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items.) 122 S & F for Anodised aluminium snap grid size (605mmx605mm) frame work for false ceiling with Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified. 123 M & L for Exposed metal frame ceiling with 6mm calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid (Frame work for ceiling shall be measured and paid separately) complete all as specified. 124 Fixing for Exposed metal frame ceiling with 6mm calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid (Frame work for ceiling shall be measured and paid seperately) complete all as specifiedNote : Board obtained from dismantling are 60% reused 125 Aluminium panel (Total 4 mm) shall be composed of non combustible polyethylene core (3 mm) laminated and sandwitched between two fine aluminium sheets (0.5mm). The external aluminium surface shall be coated with superior quality PVDF resin coating (22 to 28 micron) to ensure durability, stability, corrosion and weather resistance. The inside aluminium surface shall be polyster coated ensuring smooth surface as per manufaturers instruction, using 2 x 1plain rectangular tube. Depending upon site condition and as approved by GE colour will be selected, 3M Adhesive tape, weathering sealent and quality hardware.Panel of 1220mm x 3660mm and 1220 x 3050mm Frame work shall be made, matching to the elevation and rigidly fixed to the building by means 3M tape. all the joints of the ACP sheet shall be finished with weatherproofing DOWCORNING 789 sealant as per manufaturers instructions. 126 M & L for Non skid white ceramic tiles 7 to 8mm thick, (square/rectangular) area of each tile exceeding 0.06 sqm but n.exc 0.11 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 15mm thick screed bed in cement and sand mortar 1:4 complete all as specified and as directed 127 S&F galvanised steel water tubing (GI pipe), medium grade with all fittings (ISI Marked) and fixed to wall, floor and ceiling or laid in trenches of following bore complete all as specified and as directed :- 128 15mm bore 129 20mm bore 130 25mm bore 131 50mm bore 132 S&F stop valve, cast copper alloy with crutch handle, screwed for iron pipe or for brass ferrule and fixed of following size complete all as specified and directed:- 133 15mm bore 134 20mm bore 135 S&F 15 mm bore bib taps, cast copper alloy CP with crutch handle, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. 136 S&Fshower rose 125 mm size chromium plated with or without swivel joints, any size, including fixing to15mm GI pipe or union complete all as specified and directed. 137 S&F15 mm bore hot & coldbasin mixer, cast copperalloy, with capstan heads, chromium plated, Fancy type screwed down for pipe,high pressure, screwed for iron pipe complete all as specified and directed. 138 S&F PVC connection 15 mm size with PTMT nut of following length complete all as specified and directed :- 139 450mm 140 S&F gun metal globe or gate valves, (ISI marked), with iron wheel head, screwed both ends for iron pipe and fixed, for following bore complete all as specified and directed:- 141 15 mm Bore 142 25 mm Bore 143 50 mm Bore 144 Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil comlete all as specified and directed. 145 Excavating over areas, n exc 1.5m deep and gettingout in soft/ loose soil complete all as specified and directed. 146 Excavating over areas, in following depth and gettingout in soft/ disintegrated rock complete all as specified and directed :- 147 Depth not exc 1.5m deep 148 Excavating in trenches nexc 1.5 m width and nexc 1.5 m in depth for foundation etc / for laying of cable/ pipe etc nexc 10 sqm on plan and nexc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. 149 Excavating in trenches nexc 1.5 m width and nexc 1.5 m in depth for foundation or for shafts, well cesspits, manholes etc / for laying of cable/ pipe etc nexc 10 sqm on plan and nexc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed. 150 M & L for cement concrete work in pavement/hard-standing of flexural strength 40kg/ per square centimeter in field using 400 kg of cement per cubic meter, thickness of concrete 25 cm or less complete all as specified and directed. 151 M&L for forming contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade A complete all as specified and directed. 152 M&L for spike rolling to surface or making impressions of expanded metal, whilst the concrete is green complete all as specified and directed. 153 M&L for continuous brick edging; with burnt clay bricks of sub class B with width equal to the depth of the brick; laid dry on end vertically in groundincl all earth work complete all as specified and directed. 154 M&L for 75 mm thick PCC (1:4:8) type D2, (40 mm graded stone agg) as in sub base of hardstanding/ footpath complete all as specified and directed. 155 M & L for 80 mm thick rubber moulded machine pressed precast concrete interlocking paver block with grey cement & no pigment any shape and size confirming to IS-15658-2006 of M-40 Grade as in floor etc, complete all as specified and directed. 156 M&L concrete bed to drain pipes in PCC (1:3:6) type C2 (using 40mm graded stone aggregate) including packing under and haunching against the sides of pipes after they are laid on slope and tested for 150 mmbore sewer pipe line complete all as specified and directed. 157 S & F of 150 mm bore reinforced concrete pipe class NP3 laid, jointed with collar with and including one coller for each length of pipe complete all as specified and directed. 158 M & L for brickwork with fly ash bricks, straight or curved on plan exc. 6.00 m mean radius, built in cement mortar 1:6 complete all as specified and directed. 159 M&L for PCC (1:2:4) type B-1, using 20mm graded stone aggregates, as in kerb/ benching/ coping, bed plates, for fixing of hold fast,water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and directed. 160 M & L for 15 mm thick rendering in cement mortar 1: 4 using WPC @ 3 % by weight of cement on fair faces of bricks walls including finishing the surface even and smooth without using extra cement complete all as specified and directed. (NOTE: - WPC shall be measured and paid separately under respective item as Supply only.) 161 M & L for 15 mm thick rendering on other than fair faces of brick work or stone masonry surfaces with cement mortar 1:6 finished even and fair complete all as specified and directed. 162 Supply only WPC integral water proofing compound complete all as specified and directed. 163 Construction of 50 users septic tanks including excavation in soft/loose soil, PCC 1:2:4 in foundation, brick work in CM 1:4, RCC M-30 slab cover including RCC precast manhole cover having 6mm plate embedded all around/fibre reinforcement cover with angle iron frame vent shaft and sludge chambers etc. complete all as specified and directed, (Ref TD-217 Sh 1/7 to 7/7). 164 Construction of soakage well 1.2m dia and 3.0m deep, excavation and earth work in soft/loose soil, PCC (1:3:6) using 40 mm graded stone aggregate in foundation, honey comb brick work in CM (1:4), RCC M-25 as in slab, complete all as specified and directed (Ref TD-309 Sh 1/4 to 4/4). 165 M&L for PCC (1:3:6) type C1 (Using 20 mm graded stone aggregate) as in coping, roof kerb, cill, bed block, block for insertion of hold fast of door and window with and including formwork complete all as specified and directed. 166 M & L for 10 mm thick rendering in cement mortar 1:4 on fair faces of bricks walls including finishing the surface even and smooth without using extra cement complete all as specified and directed. 167 M & L for 15 mm thick rendering in cement mortar 1:4 on other than fair faces of bricks walls including finishing the surface even and smooth without using extra cement complete all as specified and directed. 168 M&L for walling of random rubble, uncoursed well bonded, bedded and solidly hearted, stone masonary work built in CM (1:6) complete all as specified and as directed. Note :- Only quantity of PCC bond stone to be deducted from quantity of random rubble masonary. 169 M&L for Precast PCC (1:3:6) type C-1, using 20mm graded crushed stone aggregate as in bond stones in lieu of stone bond stones, set in cement mortar (1:6), complete all as specified and directed. 170 M&L for stone boulder or broken stone hand packing (Any thickness)at back of wall over arches etc and raising (or lowering) to the required level, complete all as specified and as directed. 171 M&L for raised pointing in cement mortar (1:4) to random rubble masonary uncoursed or brought upto course complete all as specified and directed. 172 Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surfacae not exceeding 40mm to face stone for Lime or sand stone and dressing of face beds and joints, as specified of random rubble walling, uncoursed or brought upto course complet all as specified and directed. 173 S&F PVC (SWR) pipes single socketed in any length with rubber ring joints and laid in trenches or in floor of following size complete all as specified and as directed :- 174 110 mm bore 175 M & L for concrete bed in PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in bedding for drain pipes including packing under and completely surrounding pipes with concrete after they are laid & tested in for 110 mm bore pipe complete all as specified and directed. 176 S&F PVC (SWR) pipes single socketed in any length with rubber ring joints and fixed to wall of following size complete all as specified and as directed :- 177 110 mm bore 178 Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter complete all as specified and directed. 179 M&L for RCC (design mix) M-25 (20mm graded aggregates) as in walls, retaining wall, basement wall etc.complete all as specified and directed. 180 M & L for 15 mm thick rendering in cement mortar 1:4 on fair faces of bricks walls including finishing the surface even and smooth without using extra cement complete all as specified and directed. 181 M & L for black bituminous paint to surfaces of any description wood, steel, Iron, concrete, brick, stone etc., exceeding 10 cm in width or girth complete all as specified and directed. 182 M & L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces complete all as specified and directed. 183 Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. 184 Dismantling structural steel work including doors, gates, ladder and framed work of watch tower etc complete all as specified and directed. 185 Dismantling of plain or corrugated steel sheeting, any gauge, thickness in roof coverings complete all as specified and directed. 186 Demolition of PCC in ground floorand pavings not exc 15 cm thickness below or above ground levelincluding removal of rubbish out side MOD land complete all as specified and directed. 187 Demolition of RCC n exc 15cm thick (below or above grong level) including cutting of reinforcement to facilitate demolition complete all as specified and directed. Note : Reinforcement obtained from demolition will be considered credit Sch as scrap iron. 188 Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) of following size complete all as specified and directed:- 189 Area not exc 1.5 sqm each 190 Area exc 1.5 sqm but not exc 4 sqm each 191 Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. 192 Dismantling of wall and ceilingboards ( fibre, pulp insulation etc.) or insulation boards/ slabs/ blankets of any thickness, including cover fillets complete all as specified and directed. 193 Demolition of reinforced cement concretein Valley Gutter,Column etc andremoving unserviceable material out side cantt area complete all as specified and directed.. 194 Dismantling of ACP Sheet complete all as specified and as directed. 195 S&F connecting & testing distribution board of sheet metal enclosures double door, IP-43, 240V, for using MCBs / MCB isolators with having tinted copper bus bars suitable for 200 Amps ratinghaving following capacity complete all as specifiedanddirected 196 DB SPN, 12 way 197 DB SPN, 8 way 198 S&F MCB single pole with thermal over load as well as magnetic short circuit tripping device with quick break trip free mechanism, robust design and terminals having heat resistant moulding suitable for single phase circuit of 240 volts and 6 to 32 Amps current rating , B Series, 10 KA complete all as specifed and directed. 199 S&F MCB Single pole and Neutral with thermal over load as well as magnetic short circuit tripping device with quick break trip free mechanism, robust design and terminals having heat resistant moulding suitable for single phase circuit of 240 volts and 6 to 32 Amps current rating , C Series, 10 KA complete all as specifed and directed. 200 S&F MCCB three pole and Neutral with thermal over load as well as magnetic short circuit tripping device with quick break trip free mechanism, fix type suitable for three phase circuit of 430 volts of current rating 63/100 Amps, C Series, 16 KA breaking capacity suitable for TPN DB 4/6/8/12 way complete all as specifed and directed. 201 S&F LED fitting 18/20 Watt, 230V,1200 mm long, Surface mounting, withintegrated electronic driver high transcluent frosted diffuser, bipin holders, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. 202 Dismantling / taking down and S&F LED 2x2 feet squarefitting 2x18 Watt, 230V,false ceiling mounting, withintegrated electronic driver high transcluent frosted diffuser, bipin holders, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. 203 Supply & Fixing Lamp holder/Batten holder with PVC/Polycarbonate body angular/straight fixed on plastic laminated sheet cover round shape 3 mm thick including 01 No LED 10 W suitable for 230 V complete all as specified and directed. 204 S&F Exhaust fan 250 mm sweep PVC bodywith louver shutter complete including M&L for providing/cutting the round hole of required size in wall finishing the same supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 23/0.0076 copper cable, rubber insulated from ceiling rose to exhaust fan motor and writing MES No with black synthetic enamel paint 2.0 cm high complete all as specified and directed. 205 S&F heavy duty Exhaust fan 450 mm sweep metal body, double ball bearing with louver shutter complete including M&L for providing/cutting the round hole of required size in wall finishing the same supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 23/0.0076 copper cable, rubber insulated from ceiling rose to exhaust fan motor and writing MES No with black synthetic enamel paint 2.0 cm high complete all as specified and directed. (Note:- Exhaust fan to be connected by submain wiring 1.5 sqmm catered in separate item of the schedule). complete all as specified and directed. 206 S&F LED linear mirror light Aesthetically designed, Provided with a high output PMMA diffuser for glare free light 7 watt. Dimension: 300 mm. incl lamp etc. complete with all accessories in and including connecting up with twin core twisted flexible copper conductor cable with suitable size copper wire complete all as specified and directed. 207 M&L Sub main wiring with 2 single core 1.5 sqmm, PVC insulated PVC unsheathed stranded copper conductor cable in and including PVC concealed/surface conduit,25 mm or higher dia. ISI marked, medium grade complete with all conduit accessories/ fittings including extension earth wire with 1x1.0 Sqmm single core PVC insulated, unsheathed copper cable fixed along with sub main in PVC conduit and connecting to earth dolly with all fixing material complete all as specified and directed. Note :- Two run of 1.5 sqmm & one run of 1.0 sqmm copper cablemeasured as one unit.Note:- Two light points will be controlled by one way switch 5 Amp in false ceiling of 7 mtr height in hall. 208 M&L Sub main wiring with 2 single core 4 sqmm, PVC insulated PVC unsheathed stranded copper conductor cable in and including PVC concealed/surface conduit,25 mm or higher dia. ISI marked, medium grade complete with all conduit accessories/ fittings including extension earth wire with 2.5 Sqmm single core PVC insulated, unsheathed copper cable fixed along with sub main in PVC conduit and connecting to earth dolly with all fixing material complete all as specified and directed. Note :- Two run of 4.0 sqmm & one run of 2.5 sqmm copper cablemeasured as one unit.complete all as specified and directed. 209 Sub main wiring with 2 single core 6 sqmm, PVC insulated PVC unsheathed stranded copper conductor cable in and including PVC concealed/surface conduit,25 mm or higher dia. ISI marked, medium grade complete with all conduit accessories/ fittings including extension earth wire with 4 Sqmm single core PVC insulated, unsheathed copper cable fixed along with sub main in PVC conduit and connecting to earth dolly with all fixing material complete all as specified and directed. Note :- Two run of 6.0 sqmm & one run of 4.0 sqmm copper cablemeasured as one unit. 210 Supply & fix LED street light 48 watt made up of pressure die cast aluminium housing with toughned glass and individual high power LEDs with secondary optics with IP 66 protection, impact resistance of IK07 & 10 KV external SPDincluding cost of GI pipe, bracket, clamps, nut & bolts etc required for fixing of fittings complete all as specified and directed. 211 S&F blanking plate complete all as specifed and directed. 212 M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground levelat any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 4mm GI Wirecheck nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI strip upto 7.5 mtrs long with 15 mm dia medium grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighing not less than 4kg/sqm in lieu of CI cover.(ii) Cost of additional GI strip more than 7.5 mtrs will be measured and paid seperately under relevant items. 213 Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete. 214 Fixing only LED 2x2 feet squarefitting 2x18 Watt, 230V,false ceiling mounting, withintegrated electronic driver high transcluent frosted diffuser, bipin holders, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. 215 Dismantling and taking down u/s sub-main wiring/service wire of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc. complete all as specified & as directed. 216 S & F switch Modular single pole,one way 6 Amps , 1 module,230 volts, 50 hzcomplete all as specified and directed. 217 S&F ceiling rose 65 mm 3 terminal / PVC/ polycarbonate, isolated body complete all as speccified and directed 218 M&L for sand cushioning with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and directed.Note:- Punned thickness shall be considered for payment purpose. 219 Supply and laying cable protection bricks, common burnt clay sub class B designation 75 for protection of UG cable laid in trenches with axis of the bricks perpendicular to the axis of the cable complete all as specified and directed. 220 Supply laying, testing and commissioning of 1100 volts grade XLPE insulated PVC sheathed steel armoured alluminium stranded conductor LT UG cable (conforming to IS 1554) in trenches /ducts /through RCC pipes under roads of size 4 core 25 sqmm complete all as specified and directed.
Contract Date: Mar 20, 2026 Contract Value : 1.46 Crore
Statutory Bodies & Commissions/Committees No of Bidders 4
Uttarakhand View Result →
38.
Public Administrative Department #9840552 Technical Bid
Tender for Supply Of Various Material, Spares, Tools And Consumables Required For Appurtenances, Machinery And For Use During Emergency Repair And Maintenance Works Of Water Mains Under Ae Ww (Erc) Office. , Supply Of Various Material, Spares, Tools And Consumables Required For Appurtenances, Machinery And For Use During Emergency Repair And Maintenance Works Of Water Mains Under Ae Ww (Erc) Office. , Galvanised Coupling 15Mm Dia. , Galvanised Elbow 15Mm Dia. , Galvanised Nipple Double 15Mm Dia. , Galvanised Union Coupling 15Mm Dia. , Galvanised Plug Malleable 15Mm Dia. , Tap Stop Brass 15Mm Dia. , Gi Pipe 15Mm Dia. , Gi Pipe 20Mm Dia. , Gi Pipe 25Mm Dia. , Gi Pipe 32Mm Dia. , Gi Pipe 40Mm Dia. , Gi Pipe 50Mm Dia. , Hydraulic Jack 10 Ton , Single Ended Fix Spanner Slugging 36Mm , Single Ended Fix Spanner Slugging 38Mm , Single Ended Fix Spanner Slugging 41Mm , Single Ended Fix Spanner Slugging 46Mm , Single Ended Fix Spanner Slugging 50Mm , Single Ended Fix Spanner Slugging 55Mm , Long Nose Plier 8 , Allen Key Set 1.5Mm To 19Mm , File Bastard Flat 300Mm , Hack Saw Blade High Speed 300Mm , Scew Driver Sets , Diamond Point Chiesel Steel 12 X 200 , Plier Waterpump 250Mm , Combination Plier 210 Mm , Pincers Size 200 Mm , 0.01 Level Bottle 9 , Sledge Hammer Without Handle 1350 Gsm , Pvc Reinforced Flexible Hose Pipe 75Mm Dia. , Pvc Reinforced Flexible Hose Pipe 100Mm Dia. , Led Halogen Light 150 W , Led Tube Lights 20W , Mcb Dp 32A 230V , Wall Socket 3 Pin 5A , Plug Top White 3 Pin 5A , Plug Top White 3 Pin 15A , Synthetic Enamel Paint Golden Colour , Synthetic Enamel Paint Black Colour , Synthetic Enamel Paint White Colour , Hacksaw Blade Hss 525Mm , Half Round File Rough (300Mm) , Half Round File Smooth (300Mm) , Round File Rough (300Mm) , Round File Smooth (300Mm) , File Flat Smooth 12/300 , Triangular File 200Mm (Smooth) , Bench Vice 8 , Canvas/Pvc Measuring Tape 30 Mtr , Cu Flexible Cable 4 C X 2.5 Sq Mm , Tool Box Ms 425 X 200 X 200Mm 5 Compart , Floor Cleaner Acid , Toilet Cleaner , Plastic Garbage Black Bag 14X22 90Mic , Air Freshner Cube/Ball , Napthalene Balls , Cutting Goggles , Welding Nozzle , Welder Hand Gloves , Aluminium Single Ladder 12 Length , Aluminium Single Ladder 16 Length , Heavy Duty Aluminium Ladder 20 Length , Red Oxide Primer Paint , Measuring Tape 5 Mtrs , Cu Wire 1.5 Sq Mm Single Pvc , Megger Hand Operated 500V , Wd 40 Spray , Demolition Hammer 10 Kg , Demolition Hammer 16 Kg , First Aid Kit Type A , Canvas Hose Pipe 8 , Canvas Hose Pipe 100Mm , Canvas Hose Pipe 75Mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Maharashtra View Result →
39.
Defence #9663810 AOC
Tender For Comprehensive Maintenance Of Damaged Portion Of Misc B/R Items At Mo (Mb) Ghatkopar Under Ge (Nw) Bhandup; 1 Excavation in trenches n exc 1.5m wide and n.exc 1.5m depth for man holes and sewer lines etc n exc 10 sqm on plan and nexc 1.5m in depth and getting out for hard/dense soil. Complete all as specified and directed by Engineer-in-charge. 2 Demolition and breaking up 150mm drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar including bed concrete and removal of debris including sludge if any and side MoD land. Complete all as specified and directed by Engineer-in-charge. 3 M&L concrete bed to 150 mm dia pipes of cement mortar 1:3:6 type C-2 including packing under and haunching against the side of pipes after they are laid and tested Complete all as specified and directed by Engineer-in-charge. 4 M&L for reinforced concrete pipes class NP-2 ,150 mm dia laid and jointed complete with collars Complete all as specified and directed by Engineer-in-charge. 5 Demolition and breaking up 200mm drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar including bed concrete and removal of debris including sludge if any and side MoD land. Complete all as specifed and directed by Engineer-in-charge. 6 M&L concrete bed to 200 mm dia pipes of cement mortar 1:3:6 type C-2 including packing under and haunching against the side of pipes after they are laid and tested Complete all as specified and directed by Engineer-in-charge. 7 M&L for reinforced concrete pipes class NP-2, 200 mm dia laid and jointed complete with collars Complete all as specified and directed by Engineer-in-charge. 8 Demolition and breaking up 300mm drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar including bed concrete and removal of debris including sludge if any and side MD land complete. Complete all as specifed and directed by Engineer-in-charge. 9 M&L concrete bed to 300 mm dia pipes of cement mortar 1;3;6 type C-2 including packing under and haunching against the side of pipes after they are laid and tested Complete all as specified and directed by Engineer-in-charge. 10 M&L for reinforced concrete pipes class NP-2, 300 mm dia laid and jointed complete with collarsComplete all as specifed and directed by Engineer-in-charge. 11 Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc 25cm inhard / dense soil Complete all as specified and directed by Engineer-in-charge. 12 Removing Excavated soils exceeding 1.5KMbut not exceeding 5 KM and depositing where directed. Complete all as specified and directed by Engineer-in-charge. 13 S & F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall Complete all as specified and directed by Engineer-in-charge. 14 S & F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall Complete all as specified and directed by Engineer-in-charge. 15 S & F 75 mm bore PVC (SWR) bends of any radius Complete all as specified and directed by Engineer-in-charge. 16 S&F in110 mm bore PVC (SWR) tee of any radius complete all as specified & directed. 17 S & F 110 mm bore PVC (SWR) bends of any radius Complete all as specified and directed by Engineer-in-charge. 18 Cutting to existing manhole dia of pipe in 100 mm for connecting new drains, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required. Complete all as specified and directed by Engineer-in-charge. 19 All as per description of item No 18 but 150mm dia of pipe. Complete all as specified and directed by Engineer-in-charge. 20 All as per description of item No 18 but 200mm dia of pipe. Complete all as specified and directed by Engineer-in-charge. 21 All as per description of item No 18 but 300mm dia of pipe. Complete all as specified and directed by Engineer-in-charge. 22 Dismantling water tanks 250 ltr& n exc 500 ltrand removing to store of all retrieved material. Complete all as specified and directed by Engineer-in-charge. 23 Dismantling water tanks500 ltr& n exc 1000 ltrand removing to store of all retrieved material. Complete all as specified and directed by Engineer-in-charge. 24 Dismantling water tanks1000 ltr& n exc 2000 ltrand removing to store of all retrieved material Complete all as specified and directed by Engineer-in-charge. 25 S&F in repairs 500 ltrs Rotational mould polyethylene waterstorage tanks (cylinderical vertical with closed top) hoisted and fixed in position all as specified in ssr part-I Complete all as specified and directed by Engineer-in-charge. 26 S&F in repairs 1000 ltrs Rotational mould polyethylene waterstorage tanks (cylinderical vertical with closed top) hoisted and fixed in position all as specified in ssr part-IComplete all as specified and directed by Engineer-in-charge. 27 S&F in repairs2000 ltrs Rotational moulded polyethylene waterstorage tanks (cylinderical vertical with closed top) hoisted and fixed in position all as specified in ssr part-I Complete all as specified and directed by Engineer-in-charge. 28 S&F in repair 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe 20 mm dia (minimum weight- 210 gm) Complete all as specifed and directed by Engineer-in-charge. 29 All as per description of item 28 but of size 25 mm dia. Complete all as specifed and directed by Engineer-in-charge. 30 All as per description of item 28 but of size 40 mm dia. Complete all as specifed and directed by Engineer-in-charge. 31 Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 15mm Complete all as specifed and directed by Engineer-in-charge. 32 Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 20mm Complete all as specified and directed by Engineer-in-charge. 33 S&F 15mm bore GI tubes medium grade, galvanised with all fittings and fixed complete to walls and ceiling or laid in floors. Complete all as specified and directed by Engineer-in-charge. 34 All as per description of item No 33 but 20 mm bore. Complete all as specifed and directed by Engineer-in-charge. 35 S&F in repair for gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe & fixed of size 25 mm bore Complete all as specified and directed by Engineer-in-charge. 36 S&F in repair for gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed of size 40 mm bore Complete all as specified and directed by Engineer-in-charge. 37 Carrying out maintenance of entire sewage system of MO (MB) Ghatkoper area by Cleaning/clearing/ blocked sewage lines not exc. 150mm, 200mm & 300mm and removal of foreign material from inside the,floor trapNahani trap, Gully trap and drainage pipe,& re-fixing manhole covers without damaging etc,including clearing spot blockages(PVC/ SGSW/RCC hume pipe ) any depth by roddingmanually incl pumping out sludge, water from trap etc including providing trolley mounted pump set with suction pipe of adequate length and minimum60metre delivery pipeetc,daily at 0830 hrs to 1700 hrs incl disposal of debris, spoils and sludge hygienically complete all as specified and directed. by Engineer-in-Charge. Note:-(a)Sludge/de-composed materials obtained from cleaning shall be removed outside MD land by mechnical sewage cleaning tankers.(b) Rate inclusive of clearing away all grass vegetation, saplings shurbs and trees not exceeding 30 cm girth upto 3 mtrs alround the septic tank/main holes and removing rubbish upto a distance of 50 mtrs outside the periphery of the area. (c) twosafaiwala and one mazdoor shall be detailed daily forMO (MB) Ghatkoper area for thepurpose of rendering the entire sewage system functional through out the contract period.In case of failure compensation will be recovered as specified in respective PS Clause. (d)In case of blockage of sewage system the complaint shall be rectifiedwithin three hours from the time of intimation.(e)The rates quotedshall be deemed for attending day to day complaint basis and make functional the entire sewage system for the period of one month at MO (MB) Ghatkoper area. (f) The contractor/ hisauthorise supervisor of the work will report daily at complaint cell MO (MB) Ghatkoper areaat 0830 Hours to receive day to day complaints..(g). Recovery (Penalty) for not attending complaint beyond 24 hours shall beRs 200.00 per complaint per day delayed.) 38 Supply on Demand of BMC Vehicleas required forCleaning/clearing blocked sewage lines and manholes ,septic tanksof any size any depth , by pumping out /removing liquid waste / sewage , plugging the ends pipe or diverting the flow into drains if necessary , removing silt ,sludge etc , sprinking bleaching powder on the silt to avoid bad smell includingall precautionary and safety measures such as sefety belts , lighting arrangements face mask etc and removing the same (silt , sludge & other waste material ) leak proof trucks covered with tarpoline to out side of MD land all as per existing rules and regulations of civil authorities and flushing the sewer line with fresh water etc Complete all as specified and directed by Engineer-in-charge. 39 Cleaning/clearing blocked sewage lines sizeup to 100mm bore and not exc 300 mm bore and sludge chambers (PVC/ SGSW/RCC hume pipe ) gully trap of size and sahpe up to any depth by pumping out /removing liquid waste / sewage , plugging the ends pipe or diverting the flow into drains if necessary , removing silt ,sludge etc , sprinking bleaching powder on the silt to avoid bad smell includingall precautionary and safety measures such as sefety belts , lighting arrangements face mask etc and removing the same (silt , sludge & other waste material ) leak proof trucks covered with tarpoline to out side of MD land all as per existing rules and regulations of civil authorities and flushing the sewer line with fresh water etc Complete all as specified and directed by Engineer-in-charge.Note:- Length of sewage line including chambers, traps etc will be measured for payment. However cleaning of manholes shall be measured separately under appropriate item. 40 Pumping out of liquid sludge etc, from septic tank/soak well/ manhole any depth Complete all as specified and directed by Engineer-in-charge.Note:- The unit rate quoted under this item shall deemed to includethe arrangements of Sewage pump and delivery pipe minimum 60 mtr length and all necessary T&Pwith man and material and safety equipment etc. 41 M&L for Cleaning and desilting of area strom waterclosed drainage/culvertof inner girth up to & including 450mm of any depth including removal of cover slab and refixing of cover in position and making good all as directed at site including removal of silt/waste materials outside MD Land Complete all as specifed and directed by Engineer-in-charge. 42 Dismantling of MS worksof any description such as ,ladders,gates work,grating etc,including necessary straightening of bends Complete all as specified and directed by Engineer-in-charge. 43 Dismantling cast iron of any description etc Complete all as specifed and directed by Engineer-in-charge. 44 S&F Cast iron work grade FG 150, unmachined in bracket, over head tankcovers with brackets ,gully traps, grating, railing,frames,manhole covers,fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters exc 5kg each and similar articles Complete all as specified and directed by Engineer-in-charge. 45 M&L for providing factory made RCC precast cement concrete grade M-30 cover slab of size 450mmx900mmx75mm thick size set in cement mortar 1:6 including reinforcement of 8mm dia deformed bars @150mm c/c both ways etc, Complete all as specifed and directed by Engineer-in-charge. 46 M&L for providing factory made RCC precast cement concrete grade M-30 cover slab of size 600mmx900mmx75mm thick size set in cement mortar 1:6 including reinforcement of 8mm dia deformed bars @150mm c/c both ways etc, Complete all as specified and directed by Engineer-in-charge. 47 S&F for roof trusses (framed) trussed, Purlins, crane gantries, rails and fastenings and heavy brackets framing(Beam, Angle, Channel or flat section,plain plates) including distance pieces, cleats ,welding and braceing etc,Fe-410W(Gde-E-250)quality -B,including necessary scaffolding etc Complete all as specified and directed by Engineer-in-charge. 48 M&L for preparation of new surfaces of steel, of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer Complete all as specified and directed by Engineer-in-charge. 49 Dismantling floor, hearth or wall tiling incl cement mortar bedding but not backing Complete all as specified and directed by Engineer-in-charge. 50 M&L non skid coloured ceramic tiles 7 to 8 mm thick(square/rectangular) area of each tiles exc 0.06 sqm but not exc 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed with white /coloured cement to match over 15mm thick screed bet of CM 1:6 Complete all as specified and directed by Engineer-in-charge. 51 M&L glazed ceramic coloured tiles in vertical surfaces size 6 to 7 mm thick 300x200mm set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick rendering of CM 1:6 Complete all as specified and directed by Engineer-in-charge. 52 S&F in repair vitreous chine squatting pan Orissa pattern size 580x440mm white with P or S trap front or back inlet including footrest (excluding fluxing cistern and flush pipe)Complete all as specified and directed by Engineer-in-charge. 53 Supply and fix10 ltr, PVC, valveless, syphonic action type, flushing cistern, low level/ high level including inlet, ball valve, float and handle including brackets etc, Complete all as specified and directed by Engineer-in-charge. 54 Demolition of brick work or stone boulder masonry,built in cement mortar or cement lime mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work and precast concrete articles.Complete all as specified and directed by Engineer-in-charge. 55 M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 Complete all as specified and directed by Engineer-in-charge. 56 All as per description of item No 55 but except stones complete all as specified and directed. Note- Serviceable stones obtained vide item No 54 shall be reused after removing mortar and cleaning with water Complete all as specified and directed by Engineer-in-charge.. 57 M&L for brick work with sub class B bricks straight or curved on plan exceeding 6 m mean radius built in CM 1:6 Complete all as specified and directed by Engineer-in-charge. 58 Taking down cement or cement lime mortar plaster, any description on brick or stone walls etc, including rackingout joints, hacking for key, scrubbing down with water etc Complete all as specified and directed by Engineer-in-charge. 59 M/L for rendering 10 mm thick in CM 1:6 on brick walls surface finishing even and smooth (with out using extra cement)etc Complete all as specified and directed by Engineer-in-charge. 60 Material and labour rendering 15mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces finishes the surfaces even and smooth without extra cement coat including using water proofing compound 2% by weight of cement etc Complete all as specified and directed by Engineer-in-charge.Note:- Supply only water proofing compound will be measured and paid separately. 61 Supply only integral water proofing compound as approved by GE. Complete all as specified and directed by Engineer-in-charge. 62 M&L for Extra over stone walling for hammer dressing to face stone and dressing face beds and joints as specified of random rubble walling uncoursed or brought upto courses surface n exc 20 mm Complete all as specified and directed by Engineer-in-charge. 63 M&L for raised pointing in cement mortar in CM 1: 4to random or polygonal rubble uncoursed or brought up to coursesComplete all as specified and directed by Engineer-in-charge. 64 M&L for applying three coats of white wash on wall including preparation of plastered or un-plastered surfaces of walls, Complete all as specified and directed by Engineer-in-charge. 65 M&L for preparation of newplastered surfaces on walls, chajjas,filling of hair line cracks with white cement and applying two coats of 100% anti fungal weather resistant acrylic paint over a coat of acrylic primer in approved shade and as per manufacturers instructions including necessary scaffolding Complete all as specified and directed by Engineer-in-charge. 66 Demolition of concrete in ground floors (un reinforced) and paving n.exc. 15 cm thickness (below or above ground level) and removal of rubbish/ demolished materials out of MD landComplete all as specified and directed by Engineer-in-charge. 67 M&L for cement concrete type D-2 1:4:8 using 40 mm graded stone aggregate in filling foundation , sub base of floor and mass concrete Complete all as specified and directed by Engineer-in-charge. 68 M&L forcement concrete type B-1, 1:2:4 ( 20mm graded aggregate ) as in surface channels and drains etc Complete all as specified and directed by Engineer-in-charge. 69 M&L for providing plain cement concrete 1:2:4 type B-1using 12.5mm graded stone aggregate as in kerb stone coping including framed work for man holes etc including weathering ,slightly rounded or chamfered angle and throating as directed including necessary form work Complete all as specified and directed by Engineer-in-charge. 70 M&Lpreparation of new /old concretesurfaces / kerb stoneof any description and girth, not otherwise described over 10 cm width or girth and applying one coat of of synthetic enamel paint Complete all as specified and directed by Engineer-in-charge. 71 M&L 75 mm thick cement concrete type C-1, 1:3:6 (20 mm gradedstone aggregate) as inplinth protection, path Complete all as specified and directed by Engineer-in-charge. 72 M & L 25 mm thick PCC 1:2:4type B0, using 12.5mm graded aggregate as in floors toreceive surface of tile Complete all as specified and directed by Engineer-in-charge. 73 M&L screed bed or bedding layer of mortar, 20 mm thick, in cement mortar 1:6, for laying floor finishes/tiles Complete all as specified and directed by Engineer-in-charge. 74 M&L for coloured glazed chequered liquid finish cement concrete30cm x 30cm x 25mm thick With mixture of grey and white cement in equal proportions and no pigment set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles Complete all as specified and directed by Engineer-in-charge. 75 M&L 100 mm thick cement concrete type B-1, 1:2:4 (20 mm gradedstone aggregate) as inhardstanding,path etc incl finishing cement concrete surface even and smooth without using extra cement Complete all as specified and directed by Engineer-in-charge. 76 M&L PCC 1:4:8 C-2 (using 40mm graded crushed stone aggregate) as insub base ( 75mm thick ) finished even and fair Complete all as specified and directed by Engineer-in-charge. 77 M& L for 80mm thick Machine pressed precast paver block M-40 grade laid over sand cushioningafter consolidation set and levelled the paver block on proper levelwith inter locking and size conforming to IS 15658-2006with grey cement and pigment (LAQUER FINISH) etc Complete all as specified and directed by Engineer-in-charge. Note: Sand cushion will be measured separetely.Make - Super tiles/NITCO Tiles/VITCO tiles 78 Supply only sand cusion for paver blocks 79 Cleaning of PVC Water tank at any height (onaccessible/inaccessible on roofs) by removing all scale, dirt, mud ,any foreign material and removing accumulated silt, other dirty substance,algae, fungus and other bacterial material from sides/bottom of tank cleaning shall be done by draining / pumping out water/sludes from bottom removing edge and another growth from wall / floor / roof by high pressure cleaning method with jet set and again claening the tank with fresh water .Disinfecting by using UV radiator and approved chemical (chloriten) After cleaning writing letter/ figures an black ground with white enamel paint of any capacity cleaning of PVC every six months:-(i) Date of cleaning.(ii) Next due date of cleaning. (iii) Remove of the existing lettering / figures completely. 80 M&L for application of wall treatment incl surface preparation opening of cracks and application of cement based coat as per manufacturing instruction having min service life of 5 years warranty and Complete all as specified and directed by Engineer-in-charge.Make:- Themacool, Dr Fixit or Asian Paint or techno commercial equivalent. 81 Dismantling of roof terracing cement / brickconcrete (un-reinforced) and existing water proofing treatment of any thickness in any position and of any portion from top of roof of building, cleaning surface of roof with wire brush / mechanical brush and with water thoroughly to remove all dust / dirt and loose particles to expose base concrete roof slab and removal of rubbish / demolished material out of MD land Complete all as specified and directed by Engineer-in-charge. 82 M&L for PCC 1:2:4 Type B0 using 12.5 mm graded aggregate with 2% by weight of cement or as per manufacturers instructionswater proofingas in levelling course, haunching, coping and similar works over RCC roof surface and RCC over head tank top surface including rounded or chamferred on edges and formwork etc Complete all as specified and directed by Engineer-in-charge. 83 M&L for application of Roof treatment incl surface preparation opening of cracks and application of cement based coat as per manufacturing instruction having min service life of 10 years warranty and Complete all as specified and directed by Engineer-in-charge. Make:- Themacool, Dr Fixit or Asian Paint or techno commercial equivalent. 84 Taking down chowkat or frame with shutter (without taking off shutter from the frames)and including grills/ guard bars exceeding 1.5 Sqm and n exc 4 sqmeach Complete all as specified and directed by Engineer-in-charge. 85 Taking down chowkat or frame with shutter (without taking off shutter from the frames)and including grills/ guard bars not exceeding 1.5 Sqm each Complete all as specified and directed by Engineer-in-charge. 86 Taking down cup board and wiremesh orpanelledshutter of any description, exceeding 1.0 Sqmand n exc 2 sqm each Complete all as specified and directed by Engineer-in-charge. 87 S&F Flush shutter 40 mm thick , solid core construction, with block board core and plywood face panel, commercial type on both side Complete all as specified and directed by Engineer-in-charge. 88 S&F 35mm thick factory made glazed and skeleton door shutters open rebated of second class hard wood rail and styles (Hollock), prepared to receive glass/gauge etc without sash bars, edges of framing plain cham-fered or rounded, mitred and rebated sash bars, any numbers The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 Complete all as specified and directed by Engineer-in-charge.(Note :- S & F wire messshall be measured and paid for separately) 89 S&F in plain solid straight chowkats IInd class hardwoodandframe, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints. Complete all as specified and directed by Engineer-in-charge. 90 S&F in repair 40mm dia cupboard Knobs fixed with necessary screws, nuts etc Complete all as specified and directed by Engineer-in-charge. 91 S & F 300 mm long Aluminium, anodised, barrel tower bolts of extruded section and fixed Complete all as specified and directed by Engineer-in-charge. 92 S & F 150 mm thick Aluminium, anodised, barrel tower bolts of extruded section and fixed Complete all as specified and directed by Engineer-in-charge. 93 S&F 150mm size aluminium handles, cast type anodised Complete all as specified and directed by Engineer-in-charge. 94 S&F 100 mm size butt hinges medium weight stailess steel colled rolledComplete all as specifed and directed by Engineer-in-charge. 95 S&F 300mm size ordinary mild steel , rat tailed rod pattern spring including roller and roller platewelded to mild steel frame.fixed in repair Complete all as specified and directed by Engineer-in-charge. 96 S&F 300 mm long mild steel sliding door bolts plate type stone enamelled black with bright bolt not less than 16 mm dia with and including a minimum of 6 bolts and nuts, 04 Nos on bolt plate and 02 Nos on staple plate and fix Complete all as specified and directed by Engineer-in-charge. 97 S&F 300 mm long Stainless steel sliding door bolts( without locking arrangements)not less than 16 mm dia with and including a minimum of 6 bolts and nuts, 04 Nos on bolt plate and 02 Nos on staple plate and fix with as weldingComplete all as specified and directed by Engineer-in-charge. 98 M&Lpreparation of new wooden surfaces of any description and girth, not otherwise described over 10 cm width or girth and applyind one coat of pink primer and two coats of synthetic enamel paint Complete all as specified and directed by Engineer-in-charge. 99 S & F 25mm thick, block board grade 2 quality interior grade decorative type with decorativeface veneer on both face fixed as in shutters. Complete all as specified and directed by Engineer-in-charge. 100 S&F ball catches with 8mm dia steel ball and brass body and striking plate including letting in and fixed, Complete all as specified and directed by Engineer-in-charge. 101 S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm thick single side prelam PVC sheet used instead of Plain colour PVC sheet , suppling & fixing in opening as per specification & drawing Complete all as specified and directed by Engineer-in-charge. 102 S&F 30 mm thick factory made both side Prelam PVC sheet used instead of Plain colour PVC sheet. Stile and rails feathered at edges consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded palin colour PVC `C channel heaving aPanelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. Complete all as specified and directed by Engineer-in-charge. 103 Dismantling asbestos cement (corrugated semicorrugated, etc) sheets in roof covering including ridge, north light curves etc Complete all as specified and directed by Engineer-in-charge. 104 Taking down eaves gutters and rainwater pipes (any size & pattern) including all fitting, head shocs, bends etc Complete all as specified and directed by Engineer-in-charge. 105 M&L for 6mm thick asbestos cement corrugated or semi-corrugated sheet fixed with l-type or j-type or cranked hook bolts in roof,walls etc.Complete all as specified and directed by Engineer-in-charge. 106 All as per item No 105 here-in-before but except sheets Complete all as specified and directed by Engineer-in-charge. 107 S&F for Pre- Painted galvalume aluminiumzinc coatingAZ- 150 GI basedcorrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping ,drilling ofscrews/suitable lengthGI J or L hooks in roofComplete all as specified and directed by Engineer-in-charge. 108 S&F for Pre- Painted galvalume aluminiumzinc coating GI basedPlain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/rigdes, fixed with self tapping ,drilling ofscrews/suitable lengthGI J or L hooks in roof, including necessary scaffolding etc Complete all as specified and directed by Engineer-in-charge. 109 S&F 2 mm fibre glass reinforced translucent corrugated sheeting of a similar pattern as that of PPGI sheet with two corrugations side lap fixed with coach screw, GI J or L hooks in roof Complete all as specified and directed by Engineer-in-charge. 110 S&F 160mm bore PVC rain waterpipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps 8mm dia with two nuts wall nails etcComplete all as specified and directed by Engineer-in-charge. 111 S & F Steel rolling shutter ( thickness of lath 1.25mm thick) without ball bearing as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated, and including taking down of any thickness etc, complete gear operated type with bevel gear box and crank handle etc Complete all as specified and directed by Engineer-in-charge. 112 Routine maitenance of sliding doorshutter of following sizes the maintenance including the following Complete all as specified and directed by Engineer-in-charge.(i)Dismantling of MS worksof any description such as rollers pulleys, guides, bottom sliding tracks and corrugated sheets including necessary straightening of bends.(ii) Refixing the serviceable accessories such as rollers, pulleys, guides, channelsbottom sliding tracks corrugated sheets etc.(iii)Replacementof unserviceable accessories such as rollers, pulleys, guides, channelsbottom sliding tracks corrugated sheets etc.(iv) Cleaning, oiling, greasing etc complete of all movable parts all as required at site(Note- The parts and accessories to be replaced shall be measured and paid seperetely)(A) Area of shutter n.exc 5.00 sqm of each leaf 113 (B)All as per description of item No 112 but Area of shutter exc 5.00 sqm but n. exc 10.00 sqm of each leaf 114 (C) All as per description of item No 112 but Area of shutter exc 10.00 sqm but n. exc 20.00 sqm of each leaf 115 Deduct Credit for Demolished/ Dismantled material Rs. (-) 12,840.00 (Minus) as listed in Schedule of Credit.Note 1:- Tenderers will not quote against this item being a tentative amount to be considered to arrive at the Contract Sum.Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple store house having height 4 mts to 7 mts. Necessary scaffolding and saftey measures required during execution of work are including in this items.
Contract Date: Feb 07, 2026 Contract Value : 27.03 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
Maharashtra View Result →
40.
Defence #9663756 AOC
Tender For Certain B R Maintenance Repair Work To Offrs Jcos Or Md accommodation At Sunderbani Ge N Akhnoor- 1 Taking down existing old treatment incl padding water proofing plaster of any descriptionany type, roof tiles cement mortar screed bed and removing existing bitumen felt treatment incl brushing, brooming, cleaning top surfaces of roof slab to receive plaster etc incl disposing off debris from MoD land complete all as specified and directed. 2 Rendering 15mm thick in cement mortar(1:3) with water proofing compound onfair finishes of brick work or concrete surface of roof slab, to be finished even and smooth(without using extra cement ) all as specified and directed.( Water proof compound shall be measured and paid separately) 3 Roof treatment :-Water proofing treatment to RCC roof slab including parapet as under :- (a) Ist Course: Apply a coat of bituminous primer conforming to IS-3384@ 0.40 Kg /Sqm on prepared surface of plaster and after drying of primer, apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm on plastered surfaces. (b) 2nd Course :APP (Atactic Polypropylene) modified polymeric membrane, 5 layered,3 mm thick weight not less than 3.0 Kg/Sqm with 160 Grams/Sqm non woven polyester made at centre core reinforced laid with 75 mm side overlap and 150 mm end overlap, membrane has to be laid with LPG torch and overlap sealed and finished neat, all joints.(c) 3rd Course : Apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm over membrane and dusted with dry sand @ 0.50 to 1 Kg/sqm. Note : Roof treatment shall be carried out through approved manufacturers or their authorized personal only. 4 Sunken Floor treatment :-Providing and laying of water proofing treatment to sunken portion including vertical portion by applying cement slurry mixed with acrylic based polymer modified cementitious composite compound of make as specified and approved including demolition and filling of sunken floor with & including PCC 1:5:10 type E-2 (using 40mm brick aggregate).(a) First layer of slurry of cement @0.488 Kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.253 Kg/Sqm. This layer allowed to air cure for 4 Hours.(b) Second layer of slurry of cement @0.242 kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.125 Kg/Sqm. This layer allowed to air cure for 4 Hours.(c) 15mm thick plaster in CM 1:3 mixed with WP compound to be provided while concrete is still green.(d) Joint of/Trap/WC/Soil pipes shall be properly sealed with sealing compound.Note:(a) Concrete for sunken slabs shall be mixed with WP compounds as per manufacturers instructions. Before carrying out water proofing treatment the sunken slab shall be tested with water for 48 hours for any leakage /dampness is seen in ceiling below, then treatment is again carried out to RCC slab and it is again tested before passing for next stage. (The rate quoted includes water proofing compound as per manufacturers instructions).(b) Please note that only floor area shall be measured for payment purpose. 5 Preparation of new or previously untreated surface of concrete or surfaces of any description and applying two coats of aluminium paint over roof surfaces over 10cm width or girth not otherwise described, all as specified and directed. 6 Taking down chowkats or framesexceeding 1.5 Sqm and n.exc 4.00 sqm each with shutters (without taking off shutters from the frames) all as specified and directed. 7 Taking down chowkats or framesnot exceeding 1.5 Sqmwith shutters (without taking off shutters from the frames) all as specified and directed. 8 Taking down shutterof any description area exc 1 sqm but not exc 2.0 sqm each complete all as specified and directed. 9 Plain Cement Concrete 1:3:6 type C-0(using 12.5 mm graded crushed stone aggregate) as in filling of pressed steel chowkats, roof kerbs, parapets, copings, holdfasts including use and waste of formwork as applicable complete all as specified and directed. 10 Pressed steel frames for doors with one or more rebates of size 125x60mm including necessary fixing lugs, hinges, lock strike plates complete, providing mild steel 6 mm dia thresh hold bar complete all as specified and as directed. 11 Pressed steel frames for doors with one or more rebates of size 105x60mm including necessary fixing lugs, hinges, lock strike plates with mild steel 6 mm dia thresh hold bar complete all as specified and as directed. 12 Solid PVC (Door/almirah/cupboard) frames of size 50 x 47mm made out of 5mm dia plain colour PVC Sheet reinforced with MS Square tube, supplying and fixing in opening as per specification and drawing all as specified. 13 35mm thick, 2nd class hard wood plain framed, panelled (factory made) shutters (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated, complete all as specified. 14 Glazed and skeleton shutters 30 mm thick second class hard wood, opened rebated and prepared to receive wire mesh etc, edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing witre mesh etc. Size of members of shutters as specified in SSR Part-I, Sec-8, clause 8.24(a), complete all asspecified and directed. 15 Factory made solid panel PVC door incl Almirah / Kitchen Cupboard / (wooden texture) shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top and bottom rails. M.S frame shall be covered with heat channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as a gap insert for top rail and bottom rail; Panelling of plain colourPVC sheet to be fitted in the M.S frame welded / sealed to the stiles and nails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at side as per specification and drawings.Note : The external surface area of almirah/kitchen cupboards shall only be considered for payment and the contractor shall quote rate accordingly. 16 Prelaminated particle board 18/19 thick, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, complete all as specified and directed. 17 External teak wood lipping 6 mm thick fixed with nails for 18/19 mm thick board, complete all as specified. 18 S&F in replacement of Kitchen cabinets of PVC Solid board(wooden texture) size 900mmx750mmx600mm, including partitions, shelves and drawers with brass sliding rails,channels,door handles, door catchers, overall cabinet internally and externally madewith both side PVC laminated termite proof board, 18/19 mm thick, ISI marked including PVC kitchen/cup board frame of size 18mmx63mm made out of 18mm thick PVC pre-laminated ply coloured and frame shall be fixed with 50mm long steel screw inside using drilling machine and plastic fasteners, having following specifications:.....Contd to Srl item No 18.01 19 (i)Outer frame made six 50mmx47mm with same board.(ii)Shutters both side PVC laminated termite proof board, 18/19 mm thick having stainless steel soft closing concealed hinges with one No brass handle of 75mm including brass door catcher of not less than 50mm size in each shutter.(iii) Drawers made of both side PVC laminated termite proof board, 18/19 mm thick including brass handles of front and two sliding rails at sides in each drawer.(iv) All cabinets, drawers, frames, partitions and boards shall be fixed at site with brass machine screws and PVC plugs of suitable sizes. Note:(a) Only front face dimensions at site (Length and Height), shall be measured and entered in MB irrespective of Nos of partitions or drawers. Cost of all partitions as required at site shall also be deemed to have included in quoted rates and nothing extra is admissible on this account. (b) Different No of partitions and drawers may be as per site requirement with out any extra cost.(c) All labours and materials cost shall be deemed included in quoted rate. 20 300mm Mild steel ordinary rat tail rod pattern springs including roller and roller plate fixed, complete all as specified. 21 Powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. 22 Powder coated aluminium anodised door shutters(minimum thickness of powder coating 50 micron), aluminium section weighing 0.55 kg/m includingnecessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed. 23 Powder coated anodised aluminium window / ventilator( glazed / gauged skeleton shutter ), (minimum thickness of powder coating 50 micron), side hung type without sash bars, aluminium sections weighing 0.55 kg/m includingnecessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.) hinges type B-21 100mm long (2 No. ) suitable handle (1 No.) Glass shall be measured and paid separetely under relevant item of BOQ complete all as specified and as directed. 24 Door closer hydraulically regulated, aluminium extruded section body designation No. 1, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed in repairs complete all as specified and as directed. 25 Anodised aluminum grill (Anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with CP brass/stainless screws @200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as specified and directed. 26 5.5 mm thick tinted sheet glass, selectedquality and glazing with aluminium beads and rubber packing in square not exceeding 0.5 square metre in each pane, complete all as specified and as directed. 27 5.5 mm thick tinted sheet glass, selectedquality and glazing with aluminium beads and rubber packing in squareexceeding 0.5 square metre in each pane, complete all as specified and as directed. 28 Galvanised mild steel wire cloth 0.36 nominal dia of wire and average width of aparture 1.18mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and directed 29 100 mmbutt hinges, medium weight cold rolled mild steel, complete all asspecified and directed. 30 Aluminium handle cast type anodised of size 150mm ;long ISI marked complete all as specified and directed. 31 Aluminium anodised barrel tower bolt 150mm extruded section ISI marked complete all as specified and directed. 32 300mm long aluminium alloy anodised sliding door bolt with hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections & fixing bolts and sliding bolts of extruded section or cast aluminium alloy, ISI marked complete all as specified and as directed. 33 Steel windows/ventilator (Box type) factory made with double shutter with or without devetailed bar ( glass & glazed shutter) of size 79mmx39mm,16 gauge rectangular tubular frame withside hung shutter with glazing bars 12x3mm flat iron incl box type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts in each shutter 100mm long with & including 8mm square bar grills, complete all as specified & as shown on drg No. CEUZ/TD/1269/2008 Sh No 1/1 to 1/3 .Note:-(a) Fixed type glass panes shutter if any provided in above same window shall be measured and paid separately & area of these fixed shutter shall be deducted from total area of box type window for payment purpose. (b) Sheet glass/ wire cloth shall be measured & paid separately under respective item 34 Steel Windows/ventilator (Box type) factory made without glazing bars shuttersonlycomplete all as specified& as shown on drg No CEUZ/TD/1269/2008 Sh No 1/1/ to 1/3. 35 Galvanised mild steel wire cloth 0.56 nominal dia of wire and average width of aparture 1.18mm and fixed with tinned tacks or galvanised wire staples, complete all as specified. 36 S&F in repair Galvanised mild steel wire cloth 0.56 nominal dia of wire and average width of aparture 1.18mm and fixed with tinned tacks or galvanised wire staples, complete all as specified. 37 Hacking out old broken glass (any thickness, size, quality or description) from metal frames/Aluminium framesincluding punching or drilling out old glazing pins/spring clips complete all as specified and as directed. 38 Glazing with sheet glass 3 mm thick, ordinary quality and glazing with oil putty and glazing pins in squares not exceeding 0.5 Sqm in each pane, complete all as specified and directed. 39 Figured glass sheet, 3 mm thick, ordinary quality and glazing with oil putty and glazing pins in squares not exceeding 0.5 Sqm in each pane, complete all as specified and directed. 40 Floor door stopper 150mm overall length of aluminium alloy body and tongue, anodised,with hard drawn steel spring,fixed at bottom rail of door including taking down old u/s one all as specified and directed. 41 Preparation new steel and iron surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer, complete all as specified and as directed. 42 Preparation of new untreated wood and wood based surfaces of any description over 10cm in width or girth not otherwise described and painting with two coats of synthetic enamel paint over a coat of pink primer,complete all as specified and directed. 43 Curtain rod ,20 mm dia Stainless steel ,chromium platedfixed with CP bracket, incl taking down of old curtain rods, complete all as specified and directed. 44 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises,complete all as specified and directed. 45 Demolition of cement concrete(unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or aboveground level) complete all as specified and as directed. 46 PCC 1:2:4 type B-0, (using 12.5mm graded crushed stoneaggregate) 25mm thick as in subbase to floors all as specified and directed. 47 Nonskid coloured ceramic tiles 7mm to 8mm thick (square /rectangular) area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm as in floors etc,set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfacesincl 15mm thick screed bed/bedding layers in cement and sand mortar 1:4 all as specified and directed. 48 Nonskid coloured ceramic tiles 7mm to 8mm thick (square /rectangular) area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm as in dado/skirting etc,set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfacesincluding 10mm thick rendering in cement and sand mortar 1:4 finishes even and rough complete all as specified and directed. 49 Vitrified ceramic coloured tiles (light shade) 10mm thick (Square/reactangular) area of each tiles not exceeding 0.36 sqm, in floors etc set and jointed neat cement slurry and pointed in white or coloured cement to match Screed bed or bedding layer 15 mm thick for laying floor finishes in CM 1:4 complete all as specified and directed. 50 Vitrified ceramic coloured tiles (light shade) 10mm thick (Square/reactangular) area of each tiles not exceeding 0.36 sqm, in skirting etc set and jointed neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in cement and sand mortar 1:4 complete all as specified and directed. 51 Glazed ceramic coloured tiles 450x350x7mm thick on vertical surfaces such as skirting, dados and risers to steps etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 10mm thick rendering in CM 1:4 finished even and fair to receive tiles, complete all as specified and directed. 52 20mm thick granite work (table rubbed and polished) as in steps, jambs, pillars, cooking platform etc, bedded and jointed in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixure of pigment to match with shade of granite including 15mm thick screed bed in CM 1:4 after applying cement slurry @3Kg/Sqm incl provision of hole for gas pipe complete all as specified and directed. 53 Taking down cement plaster of any description including raking outjoints, hacking for key, scrubbing down with water etccomplete all as specified and directed. 54 Rendering 15mm thick cement plaster with cement mortar(1:4) on fair faces of brickwork or concrete surfacesand finished even and smooth without using extra cement complete all as specified and directed. 55 Rendering 10mm thick cement plaster with cement mortar (1:6) on other than fair faces of brickwork or concrete surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and directed. 56 Rendering 05 mm thick in cement and sand mortar 1:3 on ceilings including finishing the surface even and smooth without using extra cementcomplete all as specified and as directed. 57 Demolition of brick work built in cement mortar including all quions, arches, pillars etc. all as specified and directed. 58 Brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified and directed. 59 Brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, but except bricks all as specified and directed. 60 Walling of random rubble uncoursed, well bonded, bedded and solidly hearted built in CM 1:4 complete all as specified and directed. 61 Ditto as per item no. 59, above but except stone set set in 1:4 complete all as specified and as directed. 62 Raised pointing to random rubble, uncoursed or brought upto course masonry in CM 1:4 complete all as specified and directed. 63 Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surface not exceeding 40mm to face stones (lime and sand stone) and dressing of face beds and joints, complete all as specified and directed. 64 Preparation of newly plastered surfaces of walls andapplying two coats of oil bound distemper over a coat of chalk whitening primer complete all as specified and as directed. 65 Preparatrion of newplastered and unplastered surfaces of walls and applying two coat of cement based paint over alkali resistant priming paint all as speicfied and directed. 66 Preparation of newly plastered surfaces of ceiling andapplying two coats of oil bound distemper over a coat of chalk whitening primer complete all as specified and as directed. 67 Repair to balcony/Facia/Roof projections and soffit of chajjas etc by taking down old rendering and hacking clearly the edges and corners smooth rounded for new plastered area exceeding 30sqm in width or girth & providing 15 to 20mm thick plastering to match with the existing thickness in CM 1:3andincluding formwork up to height 7.0 mtr above ground level of bldg including two coats of Apex/cement based paint over one coat of primer complete all as specified and directed. 68 Preparation of old plastered and unplasteredsurfaces of wall and applying two coat of oil bound distemper on walls, complete all as specified. 69 Preparation of old painted surfaces by washing, rubbing down and stopping of distempered and painted walls and applying one coat of oil bound distemper complete all as specified and as directed. 70 Preparation of old painted surfaces and applying one coat of oil bound distemper on ceiling complete all as specified and as directed. 71 Preparation of old painted surfaces by washing, rubbing down and applying one coat of cement base paint complete all as specified and as directed. 72 Applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on wall surface, complete all as specified and directed.Note:-(i) The work shall be carried out in different shade and the same shall be got approved from Engineer-in-charge/GE/(ii) The work shall be carried out upto 4th storey of bldgs and no extra payment shall be admissible for necessary form work & scaffolding required for the same. 73 Preparation of old steel and iron surfaces of any description, over 10 Cm in width or girth, not otherwise described and painting with one coat of synthetic enamel paint all as specified and directed. 74 Preparation ofold wooden surfaces of any descriptionexc 10 cm width or girth, and applying one coat of synthetic enamel paint complete all as specified and directed. 75 Cleaning and removing all scale and dirt etc from 500 ltrs water tanks and from mouths of circulating pipes etc., complete all as specified and directed. 76 Cleaning and removing all scale and dirt etc from 1000 ltrs water tanks and from mouths of circulating pipes etc., complete all as specified. 77 Rotational moulded polyethylene water storage tanks of 1000 Litres capacity, (cylindrical vertical tanks with closed top) 03 layered hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including taking down existing tank complete all as specified and as directed. 78 Rotational moulded polyethylene water storage tanks of 500 Litres capacity, (cylindrical vertical tanks with closed top) 03 layered hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including taking down existing tank complete all as specified and as directed. 79 supply and fixing in repair ball valve high pressure PTMT with epoxy coated aluminium rod& high density plastic ball 20mm dia bore all as specified and directeed. 80 15 mm bore gun metal globe or gate valve with iron wheel head screwed both end for iron pipe fixed in repairscomplete all as specified and directed. 81 20 mm bore gun metal globe or gate valve with iron wheel head screwed both end for iron pipe fixed in repairscomplete all as specified and directed. 82 Taking down eaves gutters and rain water pipe , soil and waste pipe (any size or pattern ), includding all fittings, heads , shoes bends , swan-necks etc . complete all as specified. 83 110mm bore PVC SWR Type-B ( pressure not less than 6 kg /cm2) pipes single socket in any length with rubber ring joints fixed to wall etc., complete all as specified and directed. 84 75mm bore PVC SWR Type-B ( pressure not less than 6 kg /cm2) pipes single socket in any length with rubber ring joints fixed to wall etc., complete all as specified and directed. 85 PVC (SWR) bends any radius 110mm dia with oval access doors fixed in repairs complete all as specified and directed. 86 PVC (SWR) bends any radius 75mm dia with oval access doors fixed in repairs complete all as specified and directed. 87 PVC SWR 110mm dia Type-B ( pressure not less than 6 kg /cm2) pipes in any length fixed to walls with PVC/MS holder or clamps and conforming to IS-1729 complete all as specified and directed. 88 PVC SWR 75mm dia Type-B ( pressure not less than 6 kg /cm2) pipes in any length fixed to walls with PVC/MS holder or clamps and conforming to IS-1729 complete all as specified and directed. 89 PVC (SWR)110 mmjunction single, (Single T) equal or unequal ordinary or inverted with spigot or socket branch with oval access door fixed in repairs all as specified and as directed. 90 PVC junction, double (double Y), equal or unequal, ordinary or inverted with spigot or socket branch of 75mm bore with access door, complete all asspecified and directed. 91 PVC cowls 110mm fixed in repairs complete all as specified and directed. 92 PVC cowls 75mm fixed in repairs complete all as specified and directed. 93 PVC (SWR) floor trap 75mm dia, plain with grating including jointing with solvent cement complete all as specified and directed. 94 Taking up or down 15mm dia steel water tubing and connections all as specified and directed. 95 Taking up or down 20mm dia steel water tubing and connections all as specified and directed. 96 Mild steel galvanized steel tubing 15mm bore medium grade with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed. 97 Mild steel galvanized steel tubing 20mm bore medium grade with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed. 98 CP angle valve/concealed stop cock of cast copper alloy (ISI Marked) chromium plated fancy type scrwed down high pressure with capstain head screwed both ends for iron pipe 15mm bore incl add if fixed in repairs complete all as specified and directed. 99 S&F in repairs PVC valve less, Symphonic action type, flushing cistern of capacity 10 litres, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete, fixed in repairs complete all as specified and as directed. 100 Vitreous china squatting pan Orissa Pattern size 580 x 440 mmin white colour with integral foot rest incl lime mortor, S trap fixed in repairs complete all as specified and directed.Cat Part No-20042 (ECO) of Hindware or equivalent cat part of make as specified in list of makes as approved by GE. 101 Vitreous china wash down water closet pan (pedestal pattern), (size 570mmx460mmx380mm), white (excluding fixing bolts, flushing cistern and flush pipe) with P or S trap, including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc. Complete fixed in repairs complete all as specified and directed. Make- Hindware Model Universal Cat No 200012(S-25.5/P-18) or equivalent as in list of makes as approved by GE. 102 Plastic water closet seat cover, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, including taking down of existing seat cover all as specified and directed. 103 Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.2 meter long flexible spirochrome flex tube and ABS wall hook including making connections and fixed in repair in position complete in all respect as specified.Make-Jaquar Cat part no. ALD-573 or its equivalent cat part of make specified in list make, as approved by GE. 104 Toilet paper holder with flap recessed type stainless steel Complete all as specified and directed.Make-Jaquar cat part no. AQN-7753 or its equivalent cat part of make specified in list make, as approved by GE. 105 Vitreous china wall hung wash basin with fixing accessories, white, flat back, size 550mm x 440mm x 185mm full pedestal including 15mm bore CP Central hole Basin Mixer with Popup waste system with 450mm long braided hoses for mixing hot and cold water screwed down for iron pipe including 32mm dia waste coupling,waste pipe, cutting for and pinning in ends of brackets or erecting standporcelain stopper a pair of CI brackets fixed in repair complete all as specified and directed by Engineer in charge.Make-Jaquar (Queens prime) cat part no.QQP-7169BPM or its equivalent cat part of make specified in list make, as approved by GE. 106 PVC connection 15mm size of length 600mm, with PTMT nuts supplied and fixed in repairs complete all as specified and as directed 107 S&F in repair waste pipe for SINK/WHB/Urinal for 32/40mm dia all as specified & as directed. 108 Swivel shower of CP any colour for fixing with 15 mm pipe ,with shower arm of size 195 mm long with bend of 45 degree with flange of any colour supplied and fixed in repairs complete all as specified and directed. 109 Bib taps (Long body) for 15mm bore dia of pipe, fancy type chromium platedwith crutch or butterfly handle, screwed down for iron pipe or for brass ferrule and fixed in repairs complete all as specified and directed.Cat Part No-CON-107KN of Jaquar or its equivalent cat part of make specified in list make, as approved by GE. 110 Bib tap (long body)15 mm standard of PTMT any colour high pressure screwed for iron pipe and fixedin repairs complete all as specified and directed. 111 Chromium plated fancy type quarter turn Pillar cock screwed down high pressure with crutch or butterfly handle screwed both end 15 mm bore dia fixed in repairs all as specified. Make-Jaquar Cat part no. FON-40011 its equivalent cat part of make specified in list make, as approved by GE. 112 15mm bore brass CP wall mixer with provision for overhead shower arrangement with 115mm long bend pipe on upper side for mixing hot and cold water supply screwed down with connecting legs CP extension nipple & wall flange connector for hand shower arrangement with connecting Legs, wall Flanges & wall bracket for hand shower for mixing hot or cold water, screwed for iron pipe and fixed in repairs, complete all as specified and directed.Make-SOL-6273UPR of Jaquar or its equivalent cat part of make specified in list make, as approved by GE. 113 CP grating with or without hole100 mm dia fixed in repairs all as specified and as directed. 114 Stainless steel Soap dish, any type, fixed with plugs chromium plated brass screws fixed in repairs complete all as specified and as directed.Cat part No-AQN-7733 of Jaquar or its equivalent cat part of make specified in list make, as approved by GE. 115 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC Sheet 0r 6mm thick commercial plywood fixed to wdn plugs with CP Brass screws and cup washers fixed in repairs, completeall as specified and as directed.
Contract Date: Feb 16, 2026 Contract Value : 11.62 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 5
Jammu And Kashmir View Result →
41.
Defence #9578110 AOC
Tender For Special Repair To Mes Installation At Af Stn Bihta.; 1 B/R WORKS 2 Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting outin SOFT/LOOSE soil complete, all as specified. 3 Excavating in post holes (or similar holes) each n exc0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface in SOFT/LOOSE soil complete, all as specified. 4 PCC type B-1 (1:2:4), using 20 mm graded stone aggregates in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified. 5 Plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation filling & mass concrete complete all as specified. 6 2nd Class hardwoodof size 105 mm x 60 mm made wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints supplied and fixedcomplete all as specified. 7 Factory made 35 mm thick ,2nd class hard woodGlazed and skeleton shutters, open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a);,etc complete all all as specified. 8 Factory made, 35 mm thick, second class hard wood, plain framed, hammer marked, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete, all as specified. 9 Factory made solid PVC Door frame of size 50mm x 47mm made out of 5mm thick wood grain finished colour PVC sheet reinforcedwith M.S. Square tube, suppling & fixing in opening, complete all as specified. 10 Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded wood grain printed PVC Sheet& 5mm thick x 15mm wide PVC sheet beadingused inside stiles and rails and decorative PVC beading of 10mmx10mm (90 Degree)used instead of exposed portion of PVC sheet beading & PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and a gap insert for top rail and bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded /sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site all as specified in SSR part-II & part-I. 11 Pressed steel frames of size 105 mm x 60 mm made out mild steel pre-painted white sheet 1.25 mm thick,for doors with one or more rebates including necessary fixing lugs, 100 mm size medium grade mild steel hinges, lock strike plates etc including providing PCC (1:3 :6)type C-0 using 12.5 mm graded crush stone aggregate for filling back of chowkhats complete all as specified. 12 Pressed steel frames of size 125 mm x 60 mm made out mild steel pre-painted white sheet 1.25 mm thick,for doors with one or more rebates including necessary fixing lugs, 100 mm size medium grade mild steel hinges, lock strike plates etc including providing PCC (1:3 :6)type C-0 using 12.5 mm graded crush stone aggregate for filling back of chowkhats complete all as specified. 13 Aluminium anodised barrel tower bolt of extruded section 150mm long, ISI marked, complete all as specified. 14 Aluminium alloy, anodised, ISI marked sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extrudedsections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy 300 mm long,complete all as specified. 15 Extruded aluminium alloy 100mm long butt hinges type B-21 with galvanised mild steel hinge pin anodisedcomplete all as specified. 16 Extruded aluminium anodised handles fabricated type with plate 100 mm long, ISI marked complete all as specified. 17 Double leg aluminium anodised door stopper with rubber foot, ISI marked and fixed to bottom rail of doors with steel screws, complete. 18 Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with tinned tacks or steel wire staples, all as specified. 19 Factory made steel windows with side hung shutter with glazng bars each shutter having 02 No. box type hinges & two nos. tower bolts of size not less than 150 mm size and peg stays, dovetailed or welded,including one shop coat of zink chromate primer complete. 20 Supply only chain link mild steel galvanised hot dippedfencing, 3- 4mm wirecomplete all as specified.NOTE:- The weight of chain link fencing shall be ascertained by BOO as ordered by GE and payment shall be made acoordingly. 21 Fixing only chain linkfencingincluding line wire mesh, any mesh, size and type to any types of standards rails, straining bolts, etc. including provision of binding wire complete, all as specified. 22 Mild steel round bars 10mm dia and over, cut to length, bent to shape required, for chain link fencing complete, all as specified. 23 Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed, IN REPLACEMENT, (each line wire to be measured)complete all as specified. 24 Mild steel works in hand rails, half round or other stock section or core for wooden handrail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) in-cluding all necessary drilling, bolting or riveting, etc., confirming to Fe-290-Gde E-165, complete all as specified. 25 Taking down rolling shutter ( not exceeeding 6 Sq.m area) from any location, straightening of curtains, making good of edges, guide chanels, necessary riveting/welding, repairing to hood cover, rotating shaft and refixing the same after repair, greasing the guide channel to make smooth functioning, replacement of steel spring, ball bearing etc if required complete all as specified 26 Supply only the following spares/parts/acessories of rolling shutter(s) complete all as specified.: - 27 40mm bore medium grade mild steel pipe made to shape & size as rolling shaft 28 Guide chennel 3.15 mm thick mild steel sheet made with 75mm depth including necessary hold fasts. 29 Ball bearing of suitable size and description. 30 Spring required for maintenance of rolling shutter, complete all as specified and directed 31 Rehabilation of damaged concrete beams, column, pillar by removal of damaged and loose concrete by hand tools / ligh air hammer fitted with a spade shape tool without affecting unaffected concrete portion. Surface cracks must be removed. Dirt , oil and all other loose particles should be removed by blowing with compressed air , brooms and brushes. cleaning of corrosive reinforcement and applying anti corrosive chemical (Silka Rustoff 100) layer in two coat as per manufacturer instruction and jacking with 2 mm thick welded wire mesh, after 24 hours of applying layer of cement slurry and repairing the concrete surface by guniting using mixture of cement and sand with proportion of 1:3 under a pressure of 20 to 30 N/cm2 , average thickness 40 mm and plastering the surface with cement mortar 1:4 complete all as specified and directed by Engg-in-charge. 32 Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismentling existing sheet complete all as specified. 33 25 mm thick, cement concrete type B-0, 1:2:4 using 12.5 mm graded stone aggregate, finished even & rough, as in sub floors, complete all as specified. 34 75 mm thick, cement concrete type D-2, 1:4:8 using 40 mm graded stone aggregate, finished even & rough, as in sub floors, complete all as specified. 35 Machine cut Kota stone slab flooring 18-22 mm thick and of size not less than 550x550 mm, in floors, laid over over & including 20 mm thick (average thickness) cement mortar (1:3) screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (Granite finish) complete, all as specified. 36 Machine cut Kota stone slab 18-22mm thick on vertical surfaces as in staircase riser skirting/ dado etc over and including 10 mm thick rendering in cement mortar (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified 37 Factory made PCC chequered tiles, glossy finish,ISIMarked, with grey cement & pigment, 22-25 mm thick, of size 300 mm x 300 mm, in floors, over & including 20 mm thick cement mortar (1:6) screed, set and jointed with grey cement slurry complete, all as specified. 38 Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc., and brushing a coat of cement slurry with 3 kg of cement per Sq.m, complete all as specified. 39 Rendering 5 mm thickon fair faces of concrete surfaces, finished even and smooth on ceiling in cement mortar (1:3), complete all as specified. 40 Rendering 15 mm thickon fair faces of brick work or concrete surfaces, finished even and fairon walls in cement mortar (1:6)complete all as specified. 41 Rendering 15 mm thickon fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:4), mixed with water proofing compound as per manufacturers instructions, complete all as specified.NOTE:- WPC will be measured and paid for separately under respective item of BoQ. 42 Supply only water proofing compound, ISI marked, complete all as specified. 43 Two coats of white wash on old ceiling surfaces, including preparation of surfaces, complete all as specified. 44 Three coats of white wash on new plastered ceiling surfaces, including preparation of surfaces, complete all as specified. 45 Two coats of cement base paint on new plastered wall surfaces, including preparation of surfaces, complete all as specified. 46 Prepration of new plasterd wall surfaces of any description complete all as specified and applying the following: -(a) Applying wall care putty, in two coats& smoothening the surfaces etc. as specified (preparatory to paint as directed). (b) Two coats of interior acrylic distemperover and including a coat of acrylic emulsion primer 47 Prepration of new plasterd wall surfaces of any description & applying Two coats of exterior acrylic emulson over and including a coat of water based exterior primer complete all as specified. 48 Complete removal of existing treatment from plastered wall, pillars, cornices surfces and preparation of the surfaces to the entire satisfaction of EIC and applying the following treatment: - (a) Applying wall care putty, in two coats& smoothening the surfaces etc. as specified (preparatory to paint as directed). (b) Two coats of interior acrylic distemperover and including a coat of acrylic emulsion primer. 49 Complete removal of existing treatment of any description on wall& applyingTwo coats of exterior acrylic emulsion over and including a coat ofwater based exterior primer & including prepration of wall surfaces of any description complete all as specified . 50 Sheet glass 4mm thick ordinary quality and glazing with oil putty or wooden beads in squares n. exc. 0.5 Sq.min each paneincluding hacking out old broken glass (any thickness, size, quality or description) from wooden/ metal frame including punching or drilling out old glazing pins/spring clipscomplete all as specified. 51 Applying one coat (finishing coat) of synthetic enamel paint, including preparation of old painted wood and wood basedsurfaces of any description not other wise described over 10cm width or girth and complete all as specified. 52 Applying one coat (finishing coat) of synthetic enamel paint including peparation of old painted steel & iron surfaces of any description not other wise described over 10cm width or girth, complete all as specified. 53 Two coatsof synthetic enamel paintover oldsteel or iron surfaces of any description not other wise described over 10cm width or girth in camouflage pattern by using different tints of irregular shape in any type of building/structure including RCC overtank of any height & including preparation of surfaces, complete all as specified. 54 Two coatsof synthetic enamel paint over & including a coat of pink primer over new wood and wood based surfaces of any description not other wise described over 10cm width or girth including preparation of surfaces, complete all as specified 55 Two coats of synthetic enamel paint over & including a coat of red oxide primer oversteel & iron (new) surfaces of any description, not otherwise described, over 10 cm in width or girth, including preparation of surfaces complete all as specified. 56 Steel tubes ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors including taking down existing tube of following size: - 57 15mm bore 58 20mm bore 59 Concealed stop valve/cock, cast copper alloy, chromium plated, with wall flange, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE: PRAYAG Cat No. P-6518 or equivalent make mentioned in Appndix B. 60 Bib tap, cast copper alloy, chromium plated fancy type, long body with wall flange, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE:PRAYAG Cat No. P-6508 or equivalent make mentioned in Appndix B. 61 Pillar tap, cast copper alloy, chromium plated fancy type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE: PRAYAG Cat No. P-7802-N or equivalent make mentioned in Appndix B. 62 PVC connections 15 mm size of length 450 mm with PTMT nuts, IN REPAIRS, complete all as specified. 63 Soap dish stainless steel chromium plated decorative type approximate size 160x160x90mm, IN REPAIRS, complete all as specified. 64 Brass chromium plated towel rail600 mm long, fixed to wall with SS screws and PVC rawl plugs, IN REPAIRS,complete.MAKE: PRAYAG Cat No. CPA-10 or equivalent make mentioned in Appndix B. 65 Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm, ISI marked, white, with integral foot rests (excluding flushing cistern and flush pipe), 110x125 size uPVC P trap & necessary joints, cement concrete, IN REPAIRS, complete all as specified. 66 Vitreous China urinal, bowl type (back or corner wall type ) size 465 x 355 x265mm, ISI marked, white, with grating and union for discharge pipe completed, IN REPAIRS, complete all as specified. 67 PVC flushing cistern 10 litre capacity, syphonic action type, any shade, dual flush, ISI marked with flush pipe and all fixing acessories,IN REPLACEMENT, complete all as specified. 68 Overhead ABS 100mm shower with brass arm 225 mm long with flange andfixed in position, IN REPAIRS, complete.MAKE: PRAYAG Cat No. CPOH-2 or equivalent make mentioned in Appndix B. 69 uPVC pipes 75 mm external dia, type-B, ISI marked (IS:13592) single socketed in any length with rubber ring joints,laid in trenches, under floors or fixed to walls as SWR pipes, IN REPLACEMENT, complete all as specified. 70 uPVC pipes 100 mm external dia, type-B, ISI marked (IS:13592) single socketed in any length with rubber ring joints,laid in trenches, under floors or fixed to walls as SWR pipes, IN REPLACEMENT, complete all as specified. 71 uPVC floor trap,suitable for uPVC soil waste discharge pipes 75 mm external dia, embedded in PCC type B-1(1:2:4), IN REPAIRS, complete all as specified, 72 PVC bend any radius, suitable for PVC soil waste discharge pipes 110 mm external dia, complete all as specified. 73 PVC bend any radius, suitable for PVC soil waste discharge pipes 75 mm external dia, complete all as specified. 74 PVC vent cowl 75-110 mm external dia, IN REPAIRS, complete all as specified. 75 E/M WORKS 76 Point wiring with multi-stranded copper conductor, single core, FRLSH PVC insulated and unsheathed cable, including FRLSH PVC insulated unsheathed stranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes with 3 mm thick plastic/bakelight laminated sheet cover having necessary cutting for fixing switches/ socketscomprising the following: - 77 One light/fan/exaust fan point controlled by one switch (one way) of 6 Amp or one fan point controlled by one switch(one way) of 6 Amp & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit, complete all as specified and directed. 78 One Socket outlet of3-pin/ 5-pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, complete all as specified and directed. 79 One socket outlet three pin, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified. 80 NOTES: (a) Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule A. (b) GI boxes shall be fixed flush to walls in position with cement mortar (1:4). 81 Switch piano flush button single pole one way, 6 Amp, complete all as specified and directed. 82 Socket outlet multipurpose having provision for 2&3 pin, 6 Amp, flush type, complete all as specified and directed. 83 Switch Socket combo of capacity 15/16 Amp, complete all as specified and directed. 84 Ceiling rose, surface bakelite, 65 x 50mm, three terminals, complete all as specified and directed. 85 Lamp (angle) holder, insulated body, cord grip pattern, complete, all as specified. 86 LED bulb 9 watt complete all as directed. 87 Surface mounted environment friendly LED 20 Wbatten with polycarbonate housing & integrated electronic driver, lumen output should not be less than 90 lumens per watt including making connections up with three core flexible copper conductor cable, IN REPLACEMENT, complete all as specified. MAKE: Havells Cat No. LUMILINENXTBS20WLED830SPCWH or equivalent in makes mentioned in Appendix B here-in-after. 88 LED street light45 watt, outdoor type pressure die cast aluminium housing, heat resistant toughtened glass with frame and lamp with minimum efficiency 110 LM/W,IP 66 protection, IN REPLACEMENT and making connections, complete.MAKE: Havells Cat part no. ENDURASUNDOWNSL45WLED765PASYBOPCor equivalent make mentioned in Appendix B. 89 Post top lantern LED type 20 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with direiver and lamp, IN REPLACEMENT, all as specified and directed. 90 Security light bracket made of 40 mm bore GI light grade pipe 1.5 metre long bend to shape including necessary welding to pole(s) or fixed with suitable size of flat iron clamps, nuts, bolts and washers etc. IN REPLACEMENT, & includingtwo coats of synthetic enamel paint over & including a coat of red oxide primer complete all as specified . 91 MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, C curve type of rating 5-32 Amp, IN REPLACEMENT,complete all as specified. 92 MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, C curve type of rating 6 to 32Amp,IN REPLACEMENT,complete all as specified. 93 Sheet metal enclosure SPN, 8 way with 100 Amp rated bus bar, 240 V, double door type. for fixing MCB’s, isolators etc., having IP-43 protection, suitable for surface and flush mounting, IN REPLACEMENT,complete all as specified. 94 Excavation in trenches in SOFT/LOOSE soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for foundation, taking out/ laying pipe line, cable etc. and getting out complete, all as specified. 95 Returning filling in including spreading, levelling, watering and well ramming in layers notexceeding 25cm thick complete all as specified. 96 Removal of excavated surplus spoil to a distance n. exc. 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified. 97 Clean dry sand ( locally available) as cushioning for under ground cable 230 mm thick (one layer of 80 mm thickness before laying the cable and other layer of 150 mm thickness after laying the cable) complete all as specified.NOTE:- Punned down thickness (over all 180 mm) shall be considered for measurement and payment. 98 Bricks as specified in PS clause 5.1, laid flat and dry in trenches over the cable for protection as length perpendicular to the direction of cable adjacent to each other complete, all as specified. 99 Boring holes under road pavement / hardstanding by trenchless technology using ultrasound technique and necessary machine for inserting & including 80-100 mm bore HDPE pipe complete, all as specified. 100 Supply, laying, jointing & testing of LT XLPE insulated cable screened,bedded, galvanised steel strip or wire armourd cable(heavy duty) 1100 volt gradewith aluminium conductor conforming to IS-7098 (Part-I -1988)laid in trenches/ ducts/ through pipes/ in floors / underroads/ hard standing /along poles and testing including taking down existing cable, complete all as specified of sectional area 101 10 Sq.mm, 2 core 102 25 Sq.mm, 4 core 103 50 Sq.mm, 3.5 core 104 95 Sq.mm, 4 core 105 GI pipe light grade with all fittings fixed as termination postal ,fixed to poles/ walls/ under floors/ under road etc including taking down existing pipe, complete all as specified of following size: - 106 40mmbore 107 50mm bore 108 80mm bore 109 NOTE FOR SERIAL ITEM NO 88 & 89:- Excavation and earth work shall be measured and paid for separately. 110 Danger notice plates made out of 1.6mm thick mild steel sheet, vitreous enamelled white letters, figures, and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 25x20cm size including taking down existing old unsv danger notice plate complete all as specified and directed by Engineer-in-Charge. 111 Danger notice plates made out of 1.6mm thick mild steel sheet, vitreous enamelled white letters, figures, and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size including taking down existing old unsv danger notice plate complete all as specified and directed by Engineer-in-Charge. 112 Rubber mat of size 1000mm x 2000mm x 19mm complete all as specified and directed by Engineer-in-Charge. 113 Ceiling fan 1400 mm sweep, 230 V with blades & down rod, minimum air delivery 210 CFM with service value 6.00 BEE, five star rated, brushless direct current motor (BLDC) and connecting up from ceiling rose incl wire or connector to fan, complete all as specified.MAKE: Havells Cat No. FHCNF5SWHT56 or equivalent in makes mentioned in Appendix B here-in-after. 114 Exhaust fan 300 mm sweep with blades, frame and louvers, AC single phase, 230 V, steel body, heavy duty, fixed to wall with 10 mm dia fasteners, nuts & bolts and connecting upfrom ceiling rose or connector to fan, complete all as specified. 115 Exhaust fan 450 mm sweep with blades, frame and louvers, AC single phase, 230 V, steel body, heavy duty, fixed to wall with 10 mm dia fasteners, nuts & bolts and connecting upfrom ceiling rose or connector to fan, complete all as specified. 116 Supply installation commissioning of water cooler fully stainless steel single phase having approx storage and nominal cooling capacity 40/80 Ltrs and connecting from existing water pipe lines all as specified and directed by Engr-in-Charge. 117 Shock treatment chart having pictorial reprresentation and shock treatment points written in two 118 Pump capacity chart on wooden board written in english language with unit namw GE (AF) bihta incl taking out old one complete all as directed by Engr in Charge. 119 Desert cooler made out of GI sheet of thickness not less than 20 gauge and top and bottom cover not less than 18 gauge, 240 volts AC, electric driven (single phase), capacity having nominal air flow capicity of 4000 Cum per Hour, complete all as specified and as directed with the following specifications:-(a)Fan sweeep 450mm with aluminium blades duly factory painted.(b)Propeller cooler fan motor max 150 watt, ISI marked.(c)Submersible pump iwht 1.50 m head and 8-10 LPM water discharge.(d)Three speed control including on /off switch.(e)Pump on/off switch(f)Capacity of water storage tank Min 100Ltrs.(g)Minimum overall size 60cm X 60cm X 120cm.(h)Min 25 mm thick cellulose evaporative Honey combed cooling pads on three sides i.e. rear, left and right.(Note : Price for installation, fixing arrangements, appropriate size cooler stand made out of 40x40x5 mm angle iron and duly painted with two coatsof synthetic enamel paint over a coat of red oxide zinc chrome primer, PCC bed block for stand and water tap connection shall be deemed inculuded in the quoted rates.) 120 Fabrication and fixing canopy headed junction box suitable for embeded on PCC foundation made out of 3.15 mm MS sheet of size 30x25x15 cm with cover , 04 nos aluminium bus bar of size 25x3 mm for three phase and neutral 01 nos 06 Amps MCB SP mounting channel for control street light/post top lantern including all electrical connections using cable gland aluminium lug, painting with two coat of synthectic enamel paint over a coat of red oxide primer on external and internal surface including taking out existing box complete all as specified and directed. 121 Supply, install, testing and commissioning of out door type cubical feeder pillar box of size 600x600x30mm Aluminium bus bar 200Amps, outer shell made out of 3.15 mm thick MS sheet inner shell made out of 2.00mm thick MS sheet and MS angle section 40x40x6mm on PCC 1:2:4 type B-1 platform60cm above the ground level and 30cm below the ground level, frame factory fabricated with front and back open able double door system complete suitable for 3 phase 4 wire 415 Volt, 50Hz. The bus bar shall be provide with sufficient holes for distribution of LT supply to 6 house, and making necessary distributions with the help of thimbles etc, IN REPLACEMENT, complete all as specified and as directed. 122 Supply, install,connecting and commissioning of CPRI approved main LT distribution panel board, indoor type, both side openable, IP-54 protection including locking arrangement with sliding door bolt, cubical type, 3 phase, 4wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated outer shell made out of 3.15mm thick MS sheet and inner shell made out of 2.0mm thick MS Sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4 Nos insulated bus bar each made of high conductivity aluminium suitable for 1200 Amps, prewired with suitable size of copper cable /insulated copper strip including suitable earth strips conforing to IS, cable glands, lugs etc, IN REPLACEMENT, suitable for and comprisig of the following:-(A)INCOMING :-(i)Digital Multifunction meter with selector switch and three current transformers of suitable ration and capacity -01 Set.(ii)Digital KWH Meter 03 Phase 20-60 Amps-01 set(iii)LED type Phase indicator lamps for three phase set of three -01 set(iv)Busbar chamber having insulated aluminium busbar, each suitable for 1200 Amps for three phases and neutral -01 set(v)MCCB, 4 Pole of capacity 800Amps, 50KA at 415 V with micro processor based relased type with O/L, S/C, E/L-01 Nos(B)OUTGOING(i) MCCB, 4 Pole of capacity 400 Amps, 36 KA at 415 V-02 Nos(ii) MCCB, 4 Pole of capacity 200 Amps, 10 KA at 415 V-04 Nos (03 Nos working and 01 Nos for standby).(iii) MCCB, 4 Pole of capacity100 Amps, 10 KA at 415 V-02 Nos (01 Nos working and 01 Nos for standby)(iv) MCCB, 3 Pole of capacity 32 Amps, 10 KA , C series at 240 V-02 Nos 123 Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GIstrip 32x6 mm as earthing lead by means ofGI or steel bolts/nuts/washers, protected by 15 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mmbore GI light grade pipe for watering and including funnel, wire mesh, RCC cover, reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with mild steel handle 12 mm dia, using round bar, PGI funnel with wire mess & frame, PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of MES Schedule Part – I. IN REPLACEMENT, complete all as specified.Note:- (i)PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.(iii) Earth resstance shall be less than 3 ohm. In case the test results are not found less than 3 ohm, complete earthing shall be redone by the contractor without any extra cost to Govt. 124 Demolition and Dismantling work 125 Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50sqm each and removing from site all as specified. 126 Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50sqm but not exceeding 4.00sqm each and removing from site all as specified. 127 Taking down shutters of any descriptionnot exceeding 1.00 sqm each and removing from site all as specified. 128 Taking down shutters of any description exceeding 1.00 sqm but not exceeding 2.00 sqm each and removing from site all as specified. 129 Taking down cement plaster of any description on brick walls or concrete surfaces etcincluding raking out joints, hacking for key, scrubbing down with water etc complete all as specified. 130 Demolition of cement concrete (unreinforced) in ground floors and pavings not excceding 15cm thickness (above or below ground level) all as specified 131 Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified. 132 Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground, embedded in natural ground etc. complete all as specified. 133 Demolition of stone slab and tiles of any description or thickness in floor, apron, platform etc laid bedded and pointed in any mortar complete all as specified. 134 Dismantling structural steel work including doors, gates but excluding framed truss, complete all as specified. 135 Dismantling fencing wire mesh, any type complete all as specified. 136 Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete with batten, casing caping of MS or and PVC conduit on surface or concealed, including switches, ceiling roses, pendants, regulators, sockets, mild steel terminal boxes etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified. 137 Note : Amount ofcredit for retrieved materials is mentionedin Sch of credit of tender documents in pdf form which will be deducted while acceptance of tender offline.
Contract Date: Feb 14, 2026 Contract Value : 28.65 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
43.
Defence #9492521 AOC
Tender For Additional / Alternator And Improvement To Smqs At Af Stn Bamrouli; 1 Taking down chowkats with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) complete all as specified and directed. 2 Taking down chowkats or frames with shutters (without taking of shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and directed. 3 S&F for Pressed steel frames of size 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate including one shop coat of primer, etc complete all as specified and directed. 4 S&F for Pressed steel frames of size 105mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plateincluding one shop coat of primer, etc complete all as specified and directed. 5 Refixing of shutter exc 1 sq. mand n exc 2 sq. min the same of opening after minor repair as directed by Engr -in-Charge 6 S & F factory made single extruded WPC (Wood Polymer Composite) solid door Frames/ Chowkhat comprising of 62 mm x 32 mm size applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum specification as per IS 15931: 2012 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast unserviceable fast/lugs/SS dash fasteners of required dia and length complete all as specified and as directed by Engr-in-Charge. 7 S&F Second class hardwood factory made glazed and skeleton door shutters 35mm thick, open rebated and prepared to receive glass, gauze, etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc complete all as specified and directed. 8 S&F Second class hardwood factory made Flush shutters 30mm thick, solid core construction, with block board core & plywood face panels, commercial type on both sides complete all as specified and directed. 9 S & F factory made28-30 mm thick single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size,modulus of elasticity 850 N/mm” and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof specification as per IS 15931: 2012 and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws complete all as specified and as directed by Engr-in-Charge.Make:- M/s Navratan Specialty Chemical LLP (Gujrat)/ M/s Sintex Industries Ltd/ M/s Accucell/ M/s Dura Plast Extrusion 10 S & F for powder coated aluminium sections for doors, windows, ventilators, door partition includingfabrication of frame shutters and fixing with necessary lugs, cleats, rollers, handles, locking arrangementetc. including all accessories such as glazings clips, and rubber beadings for fixing glass panes in framecomplete all as specified. Note : (i) Glass panes will be measured & paid separately . (ii)The quoted rate shall be inclusive of cost of rubber beading however it will be not be weighed andnot paid separately.(iii) All other minor details including cost of locking arrangement shall be included in the quotedrate.(iv) Windows all around will be sealed with silicon sealant. 11 S&F Anodised aluminium powder coated ( min thickness of powder coating 50 micron and colour as approved by GE for frame )as in window / ventilator , shutters, sliding type , aluminium section weighing not less than 0.55 kg/rm including nessecsary jointing cleats , glazing clips , rubber neoprene packing , powder coated aluminium snap bedding screw and locking arrengement etc complete all as specifioed and directed Note : glass panes shall be mesaured and paiod seopreatly as supply and fixing in respective item 12 S&FStainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplesetc complete all as specified and directed. 13 S & F4mm thick Sheet glass, ordinary qualityin square in notexc 0.5 sq.m in each pane complete all as specified and directed. 14 S & F 4mm thick Figured glass, pin head typein squares in n exc 0.5 sq.m in each pane complete all as specified and directed. 15 S&F 1.25 mm thick Mild Steel plain black sheet as in steel gates and similar work, cut to size, holes punched, including round headed screws and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded as required.complete all as specified and directed. 16 M&L for Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanksand similar work conforming to Fe 410-0 or Fe 310-0. complete all as spesified and directed . 17 M&L for preparing new or previously untreated surfaces of wood or wood based materials of any descriptionexc 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed. 18 M&L for preparing new or previously untreated steel surfaces of any description not otherwise describedover 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. 19 M&L for PCC 1:3:6 type C-0 using 12.5 mm graded stone aggregate ashold fast/filling in pressed steel frame complete all as specified and directed 20 S&F 125 mm Butt hinges, heavy grade extruded aluminium alloy with galvanised mild steel hinge pin,anodised and fixed, typeB-21 complete all as spesified and directed . 21 S&F 75mm Butt hinges,heavy grade extruded aluminium alloy with galvanised mild steel hinge pin,anodised and fixed, typeB-21 complete all as spesified and directed . 22 S&F 300 mm long heavy gradeAluminium alloy with dia 16mm, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy.complete all as spesified and directed . 23 S&F 250 mm long heavy gradeAluminium alloy with dia 16mm, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy.complete all as spesified and directed . 24 S & F 125 mm long heavy gradeExtruded Aluminium alloy handles, fabricated type, anodised.complete all as spesified and directed . 25 S & F 200 mm longheavy gradeAluminium anodised barrel tower bolts of extruded section.complete all as spesified and directed . 26 S&F for 300mm, heavy grade, ordinary rat tail rod pattern springs including roller and roller plate complete all as spesified and directed . 27 S&F for 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as spesified and directed . 28 S&F for rubber beading door seal 40x 5mm stripin bottom of door complete all as specified and directed. 29 S&F in repair 18mm thick celuka PVC sheet minimum 600 Kg/Cum density grade 1 quality one side pre-laminated and other side plain white colour to make kitchen cabinet/drawer shutters fixed with screws, solvent cement/adhesive and parliyament hinge as requred as per manufacturer instructions complete as per specifications and as directed by the Engineer-in-Charge.Note:-(i) Cup board accessories ie fittings,handles,hinges, will be measured and paid under this schedule.(ii) Quoted rates deem to be include fixing of cabinet on wall with appropriate rawl plug/ dash through fastener (hammer type).(iii) Fabrication and installation of cabinet to be carried out by authorised vendor of manufacturer only. 30 S&F in repair 18mm thick celuka PVC sheet minimum 600 Kg/Cum density grade 1 quality of both side plain white colour rigidlam glossy finish fixed with screws, solvent cement/adhesive as per manufacturer instructions to make kitchen cabinet sides top and bottom and shelves inside the cabinet completeas per specifications and as directed by the Engineer-in-Charge.Note:- (i) Cup board accessories ie fittings,handles,hinges, will be measured and paid under this schedule.(ii) Quoted rates deem to be include fixing of cabinet on wall with appropriate rawl plug/ dash through fastener (hammer type).(iii) Fabrication and installation of cabinet to be carried out by authorised vendor of manufacturer only. 31 S&F in repair fancy type decorated Stainless Steel curtain hanging rods 20 mm dia,and fixed to stainless steel bracket for hanging curtain complete all as specified and directed. 32 S&F Stainless Steelbrackets having screw for tighting of curtain rod of 20mm dia for fixing of curtain rod, complete all as specified and directed. 33 S & F Stainless Steelbright color decorative corner/end cap for Curtain rod heavy grade complete all as secified and directed. 34 S&F stainless steel peg set of six with base plate and fixed to wall/door with rawal pugs/ s/s screw all as specified and directed. 35 S&F shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 300gms) complete all as specified and directed . 36 S&F in repair CP vitreous china soap dish fancy type complete all as specifed and directed. 37 S&F 600 mmx450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick PVC sheetand fixed to wooden plugs with CPbrass screws and cup washers complete all as specified and directed. 38 S&F in repairBrass chromium plated, tubular towel rails 20 mm dia, heavy grade, D- type, 60 cm long between flanges, completed all as specified and directed. 39 S&F in repair brass chromium plated shower roses with swivel joints, 125 mm sizein square with CP long shank arm including fixing to steel pipe or union, complete all as specified and as directed. 40 S&F in repair sink with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste; including pvcwaste pipe, CP waste coupling,bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified anddirected. 41 S&F 1mm thick stainless steel 304 grade kitchen plate rack of size 750x 900mm best quality assembled with brass washer and nut and bolts including hooks (spoon/cup holders) complete all as specified and as approved by GE. 42 S&F in repairs WC squatting pan “Orissa Pattern” of size 580 x 440mm white with integral foot rest (excluding flushing cistern & flush pipe) including connection to trap and to flush pipes etc and lime concrete bedding complete all as specified in SSR and including S&F trap set complete all as specified and directed. 43 S&F in repairs PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including dual flushball valve float & handle, waste pipe & brackets complete set complete all as specified and directed. 44 S & F in repairVitreous China wash basin, flat back, size 450x300mm white, excluding taps, waste, chain and plug and porcelain stopper but including brackets. 45 S&F in repair Waste coupling of PTMT (half or full threaded) . (Minimum weight2mm45gms/40mm 60 gms waste pipe of 40mm dia suitable for WHB, kitchen sink complete all as specifed and directed 46 S&F in repair angle cock fancy type CP with long shank cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends of size 15mm bore. complete all as specified and directed. 47 S&F in repairs bib tap, cast copper alloy with capstan head, CP fancy type with long body shank, screwed down with high pressure screwed for iron pipe & fixed 15mm bore, complete all as specified and directed. 48 S & F in repair Brass CP mixer 15 mmfor mixing hot and cold water screwed down for iron pipe and fixed all as specified and directed. 49 S & F in repairCP wallmixerL bend with wall flange (provisin of over head shower)for mixing hot and cold water screwed down for iron pipe(15mm) and fixed all as specified and directed.(Make : Prayag cat part no :-9375-N or equivalent as directed by EIC). 50 S&F in repairPVC connections 15mm size with PTMT nuts of length 600 mm, complete all as specified and as directed. 51 Dismantlingtanks water tank exc 250 but n exc 500 ltr.complete all as specified and directed. 52 S&Frotational moulded polythene water storage tank of capacity 500 ltrs (Cylindrical/vertical with closed top), triple layer construction, ISI marked, hoisted & fixed in position including over flow 450mm, waste pipe 600mm long with fitting etc. of 20 mm dia directed complete all as specified and as directed. 53 S&F ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed 20mm bore minimum weight 210 gms complete all as specified and as directed. 54 S& F Stop valves/Gate valves 25 mm dia cast copper alloy,screwed down, high pressure with crutch or butterfly handel, screwed both ends for iron pipe or for unions and fixed.complete all as specified and directed. 55 Taking up or down old steel tubing 15 mm dia complete all as specified and directed. 56 Taking up or down old steel tubing 20 mm dia complete all as specified and directed. 57 Refixing old15 mm GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid infloorscomplete all as specified and directed. 58 Refixing old20 mm GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid infloorscomplete all as specified and directed. 59 S&F 15 mm GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid infloors including taking up or down old steel tube complete all as specified and directed. 60 S&F 20 mm GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid infloors including taking up or down old steel tube complete all as specified and directed. 61 M & L for post construction Anti termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron. 62 M & L for post construction Anti Termite Treatment of soil under existing floors using emulsion @ one litre per litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement :2 coarse sand) to match the existing floors 63 Dismantling of cast iron or reinforced concrete drain pipe 100mm/75mm dia of any description complete all as specified and directed. 64 S&F Cast iron soil, waste and vent pipe 100 mm dia in any length with or without ear, with cement joint, laid in trenches or in wall complete all as specified. 65 Same as per item No 64 above but except pipe of 100 mm dia. 66 S&F 100 mm cast iron sanitary connection socket to fitwc out let complete all as specified and directed. 67 S&F 100 mm cast iron sanitary connection S branch with branch 370 to 450 mm long excluding jointcomplete all as specified and directed. 68 Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories). 69 S & F of 110 mm dia(SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed 70 S & F of 75 mm dia(SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed 71 S&FPVC SWR (110) bends any radius complete all as specified and directed. 72 S&F 75 mm PVC (SWR) junction single, (singl T )(equal or unequal ), ordinary or inverted ( spigot or socket type ) or with paralle oval access doorsbranches .complete all as specified and directed. 73 S& F 110 mm PVC (SWR)vent cowl, Complete all as specified and directed. 74 M&L 75mm PVC (SWR)floor trap, plain with grating including jointing with solvent cementcomplete all as specified and directed. 75 M&L PVC(SWR) gully trap 125/110mm setting and jointing with solvent cement complete all as specified directed. 76 S&F stack clamps out of 50mm by 5 mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stays to wall or roofs for bore of 100mm complet all as specified and directed. 77 S&F stack clamps out of 75mm by 5 mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stays to wall or roofs for bore of 75 mm complet all as specified and directed. 78 M&L for 25mm thick Cement concrete (in roof ) type B0- 1:2:4 (12.5 mm grade Cement concrete type B0 Complete all as specified and directed. 79 M&L for roof treatment with damp proof course (AP Smartcare damp damp sheath exterior 5626 overtrue care exterior over wall primer 0065 of Asian paitns or make as specified in tender), complete all as specified and directed.NOTE :- THE WATER PROOFING TREATMENT WORK SHALL BE CARRIED OUT BY AUTHORISED APPLICATOR ONLY. 80 M&Lfor PCC (1:2:4) type B0 (using12.5 mm gradedstone aggregates) as in roof kerbs, Chajja of window/ventilator or mud stops, rounded or chamfered on top of chajja & side edges of surfaces upto the height of 7.00 mtr etc complete all as specified and directed. { The rate is deemed to be inclusive of scaffolding/form work } 81 Struking of existing PCC floor surface 5 to 10 mm deep picking,sweeping, clean and washing down with water to remove dust to receive cement mortar for tiling, complete all as specified and directed. 82 M&L for machine cut Kotastoneslab 18 to 20mm thick in treads, landings of stair caseover cement screed bed laid and jointedwilth grey cement slurry mixed with pigment to match the shade of the slab lincluding & grinding polishing over and including screedbed 20mm thick in cm 1:6 complete all as spd & directed. 83 M & L for machine cut Kota stone slab asin skirting, risers 14 to 16 mm thick, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with mirror polish granite finish including backing coat 10 mm thick in cm1:4 complete all as specified and directed. 84 Dismantling of stone slabs and tiles of any description or thickness in floors aprons etc including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. 85 M&L for18-20mm thick granite work table rubbed and polished for wall lining /kitchen platform over 12mm thick cement mortar 1:3 thick and pointing with white cement(1:2) using marble dustwith admixture of pigment to match with shade of granite complete all as specified and directed. 86 M&L for 18- 20mm thick granite Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in whiteement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. 87 Dismentling of floor, hearth or wall tilingincluding cement mortar bedding (but not backing)complete all as specified and directed. 88 Demolition of PCC in ground floor n.exc15cm thickness below or above ground levelcomplete all as specified and directed. 89 M&L for 25mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) complete all as specified and directed. 90 M&L for first or premium quality, Non Skid ceramic tiles(joints free)10 mm thick (Square/rectangular) area of each tile nexc 0.36in floors etc. set and jointed in neat cement slurry over 15 mm thick screed bed in cement mortar 1:6 and pointed in white or coloured cement to matchcomplete all as specified and directed. 91 M&L forfirst or premium quality, non skid ceramic tiles 10 mm thick (Square/rectangular) area of each tile nexc 0.36 for skirting/dedoetc. set and jointed in neat cement slurry over 15 mm thick screed bed in cement mortar 1:4 and pointed in white or coloured cement to matchcomplete all as specified and directed. 92 M&L for first or premium quality, Non Skid ceramic coloured tiles 7 to 8 mm thickjoint free (square/ rectagular) area of each tile exceeding 0.06 sq m but not exceeding 0.16sqm ,in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchthe shade of tile and laid over and inclduing 15mm thick screed bed layer in CM (1:6) complete all as specified and directed. 93 M&L forfirst or premium quality, Glazed ceramic tiles in vertical surface 450x 300x7 mmthick joint lesstiles set and jointed in neat cement slurry and pointed in white or coloured cement to matchthe shade tile over and inclduing 10mm thick rendering in CM (1:4) complete etc. .complete all as specified and directed. 94 M & L for 75mm thick PCC 1:3:6type C-2 (using 40mm graded agg) for plinth protrction etc complete all as specified. 95 Supply only liquidintegral water proofing compund. Make Dr Fixit/ Pidipfoor/ LW+. 96 M&L for sunkan portion including demolition of existing PCC,WC,P/S Trap and removing the material out side MD land with and including the following activities :-(a)Preparation of RCC surface of sunken slab (floor) by brushing and cleaning throughly with water (b) M & L for application of two coats of poly urethane based chemical treatment (as per manufracture instruction.(Make- Dr Fixit Rain coat classic, Asian paints, Berger)(c) M & L for 15 mm thick (1:4) plaster over chemical coating includingfinished even & smooth without using extra cement all as directed. NOTE:- (i) Continuty with cementitious water treatment beyond sunken portion in toilet shall be maintained during the process.(ii) THE WATER PROOFING TREATMENT WORK SHALL BE CARRIED OUT BY AUTHORISED APPLICATOR ONLY. 97 M&L for taking down cement plaster including tile etc and removing the material out side MD land with and including the following works :-(a)Preparation of RCC surface of sunken slab (side) by brushing and cleaning throughly with water. (b) M & L for application of two coats of poly urethane based chemical treatment (as per manufracture instruction (Make- Dr Fixit Rain coat classic, Asian paints, Berger)(c) 15 mm thick (1:4) plaster over chemical coating incl finished even & smooth without using extra cement all as directed. NOTE:- (i) Continuty with cementitious water treatment beyond sunken portion in toilet shall be maintained during the process. (ii) THE WATER PROOFING TREATMENT WORK SHALL BE CARRIED OUT BY AUTHORISED APPLICATOR ONLY. 98 M& L for cement concrete type E2 1:5:10 (40mm graded stone aggregate) as lean concrete in filling / Mass concrete complete all as specified and directed 99 M&L for water treatment (floor/wall ) including demolition of existing PCC / taking down cement plaster including tile etc and removing the material out side MD land.& Cleaning with the wire brush to dry and apply one coat of URP and cement in ratio 1:1 @ 1liter per Sqm. After the drying of this process two coat of pidifin 2K or equivalent @ 01 litre on each coat min 4 hour gap is required and M & L for 15 mm thick rendering in CM 1:4 complete includingfinished even & smooth without using extra cement all as directed.NOTE :- THE WATER PROOFING TREATMENT WORK SHALL BE CARRIED OUT BY AUTHORISED APPLICATOR ONLY. 100 Demolition to reinforced cement concrete of roofs, floors (other than ground floors) beams stair cases, landing, chajjas and similar suspended workcomplete all as specified and directed. 101 M&L for use and waste of formwork to soffits and suspended slabs such as roof slabs floor slabs landings and similar work not exceeding 200mm thick (horizontal or sloping ) for fair finish surface, complete all as specieifed and directed. 102 S&F Mild steel TMT bars 6mm to 8mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and as directed. 103 M&Lreinforced Cement concrete (1:2:4) type B-1, ( 20 mm graded aggregate ) as in chajjas/roof projection/RCC railingrepairs as in similar wk complete all as specified and directed. 104 Demolition of brickwork or stone boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and as directed. 105 M&L For Brickwork with subclass B bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 of using class designation 100 of bricks in lieu of 75all as specified and as directed. 106 Taking down cement plaster on brick or stone walls, etc, incl raking out joints, hacking for key, scrubbing down with water, etc & prepare to receive new plaster complete all as specified and directed 107 M&L for 10mm thick rendering in CM 1:6 on fair faces of brick work, surfaces finished even and fair without using extra cement complete all as specified and directed 108 M&L for 15mm thick rendering in CM 1:4 on fair faces of brick work, with mixing WPC @ 3% by wt of cement surfaces finished even and fair without using extra cement complete all as specified and directed 109 M&L for rendering 5mm thick in CM 1:3 finished even and smooth with out using extra cement in ceilingcomplete all as specified and directed 110 M&L for preparing new plaster surfaces of ceiling and applying two coats of white wash over coat of primer complete all as specified and directed. 111 M&L for preparation of new plaster surfaces of walls and applying two coats of oil bound distemper(over 1mm coat of putty) over one coat of primer on wall complete all as specified and directed by Engg-in-Charge. 112 M&L For complete removal of existing surface/treatment and Providing & applying anti algal water-based Elastomeric exterior wall finish on old as well as newly plastered surfaces including surface preparation, applying suitable wall Prime seal primer 8-10 Sqm per ltr coverage area and application of two coats (base coat 4.2 -4.7 & top coat 6-6.5 sqm per ltr coverage area ) & of paint by roller etc. complete. (Make- Dr Fixit Rain coat classic, Asian paints, Berger)NOTE : THE WATER PROOFING TREATMENT WORK SHALL BE CARRIED OUT BY AUTHORISED APPLICATOR ONLY. 113 M&L for complete removal of existing treatmenton wall , ceiling surface and applying three coat of white wash complete all as specified and directed. 114 M&L for complete removing existing treatment on wall surface and applying two coats of oil bound distemper(Over 1mm coat putty) over one coat of primer overwallcomplete all as specified and directed by Engg-in-Charge. 115 M & L Preparation of old painted steel surfaces of any description,over 10 cm width or girth and applying one coat of synthetic enamel paint (ordinary tint), complete all as specified and directed. 116 M & L for preparation of old woodenSurfaces of any description, over 10cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed. 117 S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified 118 M & L for Mixing and applying SBR latex modified cementitious bond coat using cement 2.2 kg per square metre on prepared concrete surfaces of parent material complete all as specified and as directed(Note: SBR latex shall be paid separately). 119 Supply only approved SBR latex from FOSROC/BASF/DR FIXIT/ SIKA for bonding coat (Note: Rate shall be in terms of solid contents of polymer). 120 M & L for Mixing and applying SBR latex modified cement mortar 25 mm thick in cement sand mortar in proportions of 1:3 (1 cement and 2 graded quartz aggregate) with polymer admixed in proportions as approved, including trowelling with wooden tools on prepared concrete surfaces of parent material complete all as specified and as directed(Note: Acrylic polymer shall be paid separately). 121 S&F magic eyes in the door complete all as specified and directed. 122 M&L for preparation andwriting letters or figures (block, Roman, Italic or Indian) n.exc 30 CM heinght on plaster/concrete wall/path over coat of ACE as matching with existing pattern complete all as specified & directed 123 Demolition of PCC in ground floor & pavings n.exc 15 cm thickness below or above GL, complete all as specified and directed. 124 M&L for 75 mm thick type D-2 1:4:8 (using 20mm graded stone agg) as in sub base. complete all as specified and directed. 125 M&Lfor factory made 60mm thick rubber moulded glosy finished inter locking paver block with grey cement and pigment of any type and shape the minium compressive strength not less then 350 kg/sqcm as approved complete all as specified . complete all as specified and directed. 126 M& L for 25 mm Sand filling under floor including watering and consolidation. complete all as specified and directed. 127 M&L for PCC 1:2:4 Type B1using 20mm graded aggregate as in kerb stone in sides of inerlocking tiles including slightly rounded or chamfered angles and throating as complete all as specified and directed. 128 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. 129 M&L for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements for one light, fan, bell point controlled by one switch with 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with andincluding PVC concealed conduit of medium grade with all fittingsincluding Modular metal flush box minimum 1.6 mm thick, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dollyand including cutting chases in walls / floors for concealed conduitandmaking good disturbed surfaces area by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and directed for the following:-Note: - Cutting chase to wall wherever required shall be included in the rate quoted for point wiring. 130 M&L for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements for One 3 pin switch socket outlet point 5 Amps on same board with other switch with 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with andincluding PVC concealed conduit of medium grade with all fittingsincluding Modular metal flush box minimum 1.6 mm thick, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dollyand including cutting chases in walls / floors for concealed conduitandmaking good disturbed surfaces area by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and directed for the following:-Note: - Cutting chase to wall wherever required shall be included in the rate quoted for point wiring. 131 M&L for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements for One light point controlled by two Nos two way switch with 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with andincluding PVC concealed conduit of medium grade with all fittingsincluding Modular metal flush box minimum 1.6 mm thick, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dollyand including cutting chases in walls / floors for concealed conduitandmaking good disturbed surfaces area by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and directed for the following:-Note: - Cutting chase to wall wherever required shall be included in the rate quoted for point wiring. 132 M&L for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements for One 5 Amps socket outlet on independent board with 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with andincluding PVC concealed conduit of medium grade with all fittingsincluding Modular metal flush box minimum 1.6 mm thick, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dollyand including cutting chases in walls / floors for concealed conduitandmaking good disturbed surfaces area by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and directed for the following:-Note: - Cutting chase to wall wherever required shall be included in the rate quoted for point wiring. 133 M&L for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 4 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with andincluding PVC concealed conduit of medium grade with all fittingsincluding Modular metal flush box, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 4 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dollyand including cutting chases in walls / floors for concealed conduitandmaking good disturbed surfaces by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and directed for Power socket 15 Amps on independent board. 134 M&L for Modular switch 1 way 6A, 1 module, flush button single pole, one way, complete as specified and directed by Engineer in charge. 135 M&L for Modular switch, 6 Amps, one module, two way complete all as specified and directed. 136 Supply and fixing Modular socket outlet 2 in 1, 5 pin, 6 Amps flush type white finish complete all as specifiedand as directed. 137 M&L for Modular socket outlet 2 in 1, 6 pins 6A and 16A, combined 2 module, complete all as specified and directed by Engineer in charge. 138 M&L for Modular switch 1 way 16A, 1 module, flush button single pole, one way, complete as specified and directed by Engineer in charge. 139 S & F ceiling rose surface backlite 65x50mm 3 terminals complete. 140 S&F Modular Fan step regulator, 120W - 2 module complete all as specified and directed. 141 M&L forModular bell push 5 Amps 230 V, AC circuit complete all as specified and directed. 142 M&L for call bell ding dong 230 V AC circuit complete all as specified and directed by Engr-in-Charge. 143 Supply and fixing 4 Module Gang box including Modular socket outlet 16 Ampsfor AC, 240 Volts flush type white finish including plug top 20 Amps with modulartype switch 20 Amps and LED indicator (RED) incl concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 4 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with andincluding PVC concealed conduit of medium grade with all fittings and Modular white cover plate with frame 4 module to accommodate all theaccessories complete with internal connections, fixed with chromium plated screws and washers for switches and sockets, including 4 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dollyand including cutting chases in walls / floors for concealed conduitandmaking good disturbed surfaces by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specifiedand as directed. 144 Taking down old and u/s light fittings conventional type from wall surface / ceiling or any position and making good the disturbed surfaces all as specified and directed. 145 Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. 146 Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete 147 Supply and fixing LED Light fitting 1x10 watt bulkhead luminaire including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete. 148 S&F in replacement of decorative type wall mounted luminaire (Comet)with unbreakable poly carbonate materials suitable for 1x12 watt LED bulb B22 base complete all as specified and directed by Engineer in charge . 149 Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. 150 Supply and fixing in replacement GI Pipe bend to shape 1.5 mtr (32/40mm dia as required at site) with two Nos clamps made out of 50x6mm flat and two Nos bolts with nuts duly grouted in wall or fixing on wall complete all as specified and directed. 151 Taking down carefully unserviceable DB any type/size disconnecting and making good disturbed surfaces complete all as directed. 152 Supply ,install, testing & commissioning of indoor type, wall mounted (with anchor bolts & nuts) compartmentalized type Meter Cabinet for provision and fixing arrangements of 4 nos. energy meters of overall dimension 1200mm (W) x 750mm (H) x 200mm (D) made out of 2.0 mm thickCRCASheet with front door having cut out duly covered with transparent polycarbonate / glass panel for viewing KWh meter / Timer and other door shall be opaque. All doors should have gasket and locking arrangement to meet ingress protection level IP-43. The cabinet shall be painted both internally and externally with powder coated paint (RAL 7032 : SIEMENS GREY) after necessary surface treatment. The cabinet shall be fabricated as per the drawing and comprising of following accessories :-a) Four pole MCCB, 63 Amps with breaking capacity 16 KA having fixed thermal and fixed magnetic release and spreader link at both incoming and outgoing side.- 01 No.b) Copper Bus Bar of size 25mm x 3mm duly mounted on FRP insulators and necessary drilling for 1 incoming & minimum 6 outgoing connections and duly covered with heat shrinkable PVC sleeves of standard colour code - 4 Nos.c) MCB SPN 25 Amps, 10 KA - 4 Nos ( To be connected with 4 Nos Meters)d) MCB SP 06 Amps, 10 KA -2 No ( For common lighting & Bldg Security Lights)e) Analog time switch 16 Amp-01 Nof)LED indicating Lamps, 22mm with 3 Amps SP MCB-03 Nos.g) 3 Way Bakelite strip type cable connector 30 Amps rating - 06 Nosh) Dial type DIN rail mounting, Analog Time Switch 16 Amps / 230 Volts AC 50Hz, with battery back up,24 Hrs programmable type with 1 NO & 1 NC output contact.- 01 No. (for security light).j) Internal wiringwith 1100V grade FRLS PVC insulated multi flexible copper wire of sizes duly crimped with copper lugs of suitable size & type all as mentioned below :-i) MCCB to Bus Bar - 10.0 Sqmm copperii) Bus Bar to Cable Connector via KWh meter and MCB - 6.0 Sqmmiii) Bus Bar to LED Lamp via MCB - 1.5 Sqmm 153 Supply and fixing factory made epoxy powder coated distribution board SPN 12 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, stranded DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified & directed. 154 Taking down carefully unserviceable MCB SP/SPN/Isolator of any rating/size. 155 Supply and fixing MCB single pole 240 volt B curve 10 KA 5 to 32 Amps capacity all as specified and directed incl taking down old one. 156 Supply and fixing MCB single pole & neutral 240 volt C curve 10 KA 25 to 32Amps complete all as specified and directed . 157 Taking down old and u/s sub main wiring of 2/3 runs of any sizes from any position including, making good disturbed surface of wall ceiling etc all as directed. 158 M&L for concealed sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6.0 Sqmm of voltage rating up to and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 25mm with all fittings and accessories, along with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6.0 Sqmm (green colour) as earth continuity conductor all as specified and directed. (Note : Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit) 159 M&L for taking down carefully existing ceiling fan from site before B/R repair work, and deposited to AGE E/M store yard for safe custody. 160 M&L for taking down carefully exhaust fan from site before B/R repair work, keeping in safe custody in store forgreasing / oiling of ball bearings / bushes and making it for smooth and noise free operation and painting with Hi-Gloss synthetic enamel paint of approved shade by spray painting after filling cavities and re-fixing after providing new fan clamp, nuts/bolts, washers, down rod as required and provision of 3 core copper flexible cable of size 1.0 Sqmm from ceiling rose to fan connector complete with writing of MES No. on the fan surface all as specified and directed. 161 Supply and fix exhaust fan steel body, heavy duty, double ball bearing, Copper woundedcomplete with louvers shutter, 230 volt AC, single phase, 50 Hz, 1400 RPM, 300 mm sweepwith blades, steel frame complete all as specified and directed. 162 Supply and fixexhaust fan made of sturdy Engineering plastic complete with louvers shutters , 250 mm sweep, single phase, 230 Volts AC,1200 RPM, ISI marked fixed properly at directed location with provisioning of suitable fixing/tightening arrangements and connecting/testing andincluding writing MES No complete all as specified and directed, 163 Cutting the existing wall/removing existing steel bar to make a hole for fixing of ventilation fan through packing of wooden ply to support the ventilating/ air circulating fan including necessary nut and bolts of suitable size incl making good of disturbed surface complete all as directed by Engr-in charge. 164 Supply & Fixing ceiling fan 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush less direct current (BLDC) motor, class of insulation : B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service Value ( CMM/W) minimum 6.00, Air delivery minimum 210 CMM 350 RPM ( tolerance as per IS : 374 - 2019), THD less than 10 % ,electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (max), insulation resistance more than 2 mega ohm, suitable for 230 V , 50 Hz, single phase AC supply, earthing etc including necessary connection with ceiling rose with 3 core 1.0 Sqmm PVC insulated round flexible cable and including writing MES No all as specified and as directed. 165 M&L for taking down carefully existing geyser of any type and cap from site before B/R repair work, keeping in safe custody in store for servicing and painting with Hi-Gloss synthetic enamel paint of approved shade by spray painting after filling cavities, writing of MES No. and re-fixing with new hot and cold water connection as required incl provision of 3 core copper flexible cable of size 4 Sqmm complete with 15 Amps 3-pin plug top all as specified and directed. 166 Supply and fix water heater storage vertical type, puff insulation type of 25 ltrs capacity and 1500 watts, BEE Star rated-5, with glass line inner shell with Hot & Cold pipe, water connection pipe, electric connection and necessary fixing arrangement andincluding writing MES No complete all as specified and directed. 167 Disconnecting and taking down old serviceable Energy Meters of any type / capacity after noting down the reading from meteretc. and marking the Quarter No on each meter with permanent marker pen and depositing in MES store for safe custodyand writing MES No complete and re-fixing /reconnection in new meter cabinet all as specified and as directed. 168 Material, labour jointing & testingXLPE insulated armoured heavy duty electric cable with standard aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 4 core including making connection with suitable size of cable gland, aluminium lugs etc complete including taking down old U/S cable all as specified and directed. 169 Excavation in trenches in soft/loose soil n. exc 1.5 Mtr wide and not exc. 1.5 M deep and getting out including forming bottom surface for laying of pipes complete all as specified and directed. 170 Returning filling in including spreading, leveling, watering and well ramming in layers not exc 25 mm thick complete all as specified and directed. 171 Removal of excavated material to a distance not exc 50 Meter and depositing wheredirected at a level not exc 1.5 M above the starting point complete all as specified and directed. 172 Supplying, laying and cushioning for cable protection in trenches 8 cm deep before laying cable and 15 cm deep over the cable including well punning complete all as specified and dierected 173 Supplying, laying sub class B bricks old size with axis of the bricks perpendicularto the axis of the cable as in cable protection complete all as specified and directed. 174 Supply & Fixingin replacement GI tubing light grade in trenches/fixed to wall/ceiling including required GI fitting of size 40mm dia complete all as specified and directed 175 M&L earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, buried directly in to ground ( earth pit) not less than 2.25 metres deep below GL with top edge of earth plate opt less attn. 1.50 m below ground levelsurrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, connected to GI lead wire of 4 mm dia.(7.50 m Long) by means of nuts, bolts and washers, check nuts of GIand protected by the GI pipe light grade 15 mm nominal bore(7.5 m long) for earth lead wire and watering pipe light grade of 20 mm nominal bore, 0.63 mm thick G I sheet funnel , wire mesh, earthing test pointetc complete including necessary earth work and excavation in any type of soil , PCC 1:2:4 type B1 earth pit and Precast RCC cover 65 mm thick duly reinforced with 6 mm dia. MS round bars @ 100mm C/C both ways, with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as describedin electric plate of SI Part I completeall as specified and directed and testing on completion. Note :- Ifthe desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Contract Date: Feb 09, 2026 Contract Value : 1.10 Crore
Statutory Bodies & Commissions/Committees No of Bidders 8
Uttar Pradesh View Result →
46.
Shipping #9414451 Technical Bid
Tender For Development Of Area Between Workstation North And Carpentry Shed At International Ship Repair Facility Of Cochin Shipyard Limited; 1 Providing and filling with suitable borrow material as per specifications including supply and transportation, placing in position at all levels and creating suitable bunds, leveling the surface at water-logged areas or wherever directed by engineer-in-charge, including supply, lifting, loading, transporting, unloading, breaking of clods, watering, compacting each filled up layer, by flooding/ ramming/ plate compactor or any other mechanical means, including all materials, labour, equipments, other incidental expenses, etc. all complete as directed by Engineer-in-Charge. (The quoted rate shall be inclusive of Royalty if applicable) 2 Dismantling / demolition of PCC,RCC, brick masonry, removing paver, etc., by using approved means like chiseling /pneumatic hammer for all lift and lead including clearing and disposal of debris outside ISRF premises, stacking useful material at designated location within ISRF complex, etc. complete as directed by Engineer-In-Charge. Note: 1. The structures envisaged for demolition includes septic tank, drains, soak pit etc. 2. The paver blocks shall be removed and handed over to CSL in good condition for re-use3. All structural steel items shall be handed over to CSL ISRF Scrap yard 3 Removal and disposal of accumulated debris, building waste, wooden scrap & garbage, vegetation etc., before the commencement of works including shuttering materials, scrap materials for all lift, all lead and disposal of the same outside the ISRF premises including segregating and stacking all steel materials at designated scrap yard within the ISRF premisesall complete and as directed by Engineer-In-Charge.Note: This item shall be paid only once before commencement of major works. 4 Earth work excavation in all types of Hard/dense Soil, clay, murum, boulders, Soft/disintegrated Rock for all depths and lead, including shoring, strutting, dewatering, bund making if required etc.all complete including all machinery, labour, incidental expenses and disposal of unusable excavated earth outside the owners premises as directed by Engineer-In-Charge. Contractor has to carryout earthwork excavation at inter tidal zone also. 5 Providing and laying in position plain cement concrete in 1:2:4 nominal mix with 20 mm down graded coarse aggregate as level course including dewatering, ramming, leveling, curing, shuttering, deshuttering etc. including all materials, labour, equipments, incidental expenses etc. all complete as directed by Engineer-In-charge. 6 Providing and casting in-situ Reinforced Cement Concrete in 1:1.5:3 grade at all levels including providing PVC pipes/conduits , dewatering, shuttering , de-shuttering, compacting with mechanical vibrators, hacking, curing etc. complete including all materials, labour, equipments, incidental expenses etc. all complete as directed by Engineer-In-charge. (Reinforcement, PVC pipes shall be measured and paid under relevant item.) 7 Supplying, cleaning, cutting, bending, supporting, binding with double ply of 22 SWG soft annealed wire and placing in position High yield strength deformed TMT reinforcement bars conforming to IS:1786 of grade Fe 500D,of approved make / brand on / at all levels and locations as per drawings, including handling and transportion complete for all RCC works including supplying & placing concrete cover block etc. complete as directed by Engineer-In-Charge.Note:Only authorized laps, Spacer bars, Chairs embedded in the concrete will be measured for payments. 8 Providing & making Gabion structure with Mechanically Woven Double Twisted Hexagonal Shaped Wire mesh Gabion Boxes, of required size, Mesh Type 10x12, Zinc+PVC coated, Mesh wire diameter2.7/3.7mm, mechanically edged/selvedged with partitions at every 1m interval, filled with boulders with least dimension of 200 mm, including all materials, labour, equipments, incidental expenses etc. all complete as directed by Engineer-In-charge. 9 Supplying, laying and fixing non-woven geotextile fabric of minimum 120 GSM, needle punched to form a robust permeable and durable membrane behind gabion wall landside area with minimum overlap of 300mm between joints including all materials, labour, other incidental expenses all as per directive of Engineer-in-charge.Note: Overlap shall not be paid extra. 10 Supplying, Laying and compacting of granular sub-base by providing close graded material conforming to specifications, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness on prepared surface and compacting with suitable roller/mechanical means, all inclusive of materials, labour, machinery, other incidental expenses etc. all complete as per specifications and directions of Engineer-in-Charge. 11 Providing and laying 60 mm thick M30 grade concrete paving blocks of approved colour, size, design & shape, laid in approved pattern over50mm thick compacted bed of coarse material/sand, filling the joints with sand, ramming the laid pavers, levelling to required slope and properly packing, including materials, labour, machinery etc. all complete and as directed by Engineer-in-charge.Note : Concrete kerb if additionally provided shall be seperately paid under pcc item 12 Laying interlocking paver blocks of any design/shape supplied by CSL to required line,level, curvature & pattern including 50 mm thick compacted bed of sand/coarse material , filling the joints with sand, properly packing,ramming the laid pavers, levelling to required slope etc., including labour, machinery etc. all complete and as directed by Engineer-in-charge.Note : This item shall apply on issuance of interlock paver tiles to contractor free of cost by CSL, Concrete kerb if additionally provided shall be seperately paid under pcc item 13 Fabrication, supply and fixing of FRP members as handrails, chequered plates of specified dimensions fabricated using FRP Hollow tubes, flats, angles, channels, plates etc.,with polyester resin UV stabilized FRP including materials, labour, machineries, tools, necessary fasteners, aligning, drilling, anchoring with mechanical anchor bolts, etc.all complete and as directed by Engineer-in-charge. 14 Providing and fixing Poly Vinyl Chloride pipes of below mentioned diameters and 6kg/cm2 pressure rating for drainage and sewerage purpose, laying to required gradientswherever necessary, with necessary fittings such as bends, tees, reducers, clamps etc., including dewatering, threading, cutting of pipes, carving, trenching and refilling etc. including all materials, labour, installation charges, incidental expenses etc. all complete as directed by Engineer-in-charge. 15 20mm 16 110mm 17 Providing, installing and commissioning polyethylene modular septic tank (United septic tanks Type V make or equivalent) 1600mm Dia with covers, for 100 flushings per day, including excavation, dewatering, backfilling, shoring, making connections to inlet, outlets etc including all materials, labour, installation charges, incidental expenses etc. all complete as directed by Engineer-in-charge.(Excavation & backfilling shall be paid separately under relevant item) 18 Providing circular readymade RCC Soak Pit minimum 1.0 m dia. and minimum 1.8 m deep, and mininimum 50mm thick with 50mm top cover and sufficient openings for water soaking, including excavation, dewatering, shoring, filling inside the soak pit and providing 300mm thick filter media all around the soak pit to a depth of 1.2m with 40mm aggregate, making connections to inlet including all materials, labour, installation charges, incidental expenses etc. all complete as directed by Engineer-in-charge. (Excavation will be paid separately under relevant items) 19 Providing and fixing G.I Pipes of min Dia. 80 mm, laying to required gradientswherever necessary, with necessary fittings and fixtures, including all materials, labour, dewatering, trenching, backfilling, cutting of pipes, incidental expenses etc. all complete as directed by Engineer-in-charge. 20 Providing and laying 200/150 mm thick cement concrete block masonry using blocks in sub-structure and superstructure at all levels, in cement mortar 1:5 using approved quality blocks including raking of joints, curing etc including all materials, labour, installation charges, incidental expenses etc. all complete as directed by Engineer-in-charge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
Contract Date: May 21, 2026 Contract Value : 2.19 Lakh
Local Bodies No of Bidders 3
Maharashtra View Result →
50.
Defence #9356620 AOC
Tender For Comprehensive Repair To Pathway , Drain, Hard standing And Other Misc Items At Jwg In The Aor Of Age B/R-Iii And Repair Of Refg/Ac Eqpt And Connected Wks In The Aor Of Stn Hq Poonch Under Ge 881 Ews- Demolition of cement concrete (un reinforced) in ground floors and paving n exc. 15 cmthickness, below or above ground level complete all as specified and directed. 2 Demolition of cement concrete (un reinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed. 3 Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins arches pillars etc, complete all as specified and directed. 4 Dismantling fencing wire mesh, any type complete all as specified and directed. 5 Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground posts embedded in concrete complete all as specified and directed. 6 Dismantling mild steel work of any description complete all as specified and directed. 7 Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. 8 M&L for PCC 1:4:8 type D-2 (40mm graded aggts) as in foundation and mass concretewhere required as per direction of Engineer-in- charge complete all as specified and directed. 9 M & L for Walling of random rubble, brought upto course, built in CM 1:6 complete all as specified and directed. 10 All as per item No. 9 above but except stone complete all as specified and directed. 11 M&L for brick workwith sub class ‘B’ bricks, straight or curved on plan exc. 6 m mean radius, built in cement mortar 1:6, complete all as specified and directed. 12 M&L for providing precast ce- ment concrete 1:3:6, type C1 (using 20 mm graded stone aggregate) in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts,boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling).corbels, brackets, etc. (of any section indicated), landings, cover slabs, shelves etc with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar complete with joints to match complete all as specified and directed. 13 Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints with max depression 20 mm as specified, of random rubble walling uncoursed or brought upto course, complete all as specified and directed. 14 M&L for PCC 1:2:4 Type B1(using 20mm graded agg) in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs,water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. 15 M&L for boulder filling hand packed tightly (any thickness) at back of walls over arches etc, and raising (or lowering) to the required level compete all as specified and directed. 16 M& L for flush pointing in cement mortar (1:3) to random rubble masonry complete all as specified and directed. 17 S&F in repair PVC (SWR) pipes 110 mm dia of bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. 18 M&L for rendering 15 mm thick in cement mortar 1: 4 on fair faces ofbrick work or concrete surfaces, chajja and suspended workfinished even and smooth without using extra cement, complete all as specified and directed. 19 M & L for plain cement concrete 1:2:4 type B-2, using 40mm graded crushed stone aggregates as in surfaces channels and drain complete all as specified and directed. 20 Extra for forming fair finished drain or channel 30 cm inner grith in cement concrete, using extra cement including forms, moulds mitred/stopped ends etc. complete all as specified and directed. 21 Excavation in post holes each not exceeding 0.5 cum getting out, returning, filling in, including spreading, leveling, watering and well ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, in any type of soil, complete all as specified. 22 M&L for MS work for fencing post and struts made from angle iron and flat iron in any section including cutting tops to shape , drilling holes and notching for fixing of wires etc confirming to Fe -290 grade, E-165, complete all as specified and directed. 23 Supply only chain link MS zink coated 60gm/sqm as per IS 4826 fencing of any mesh size and 3mm dia of wire complete all as specified and directed.NOTE: This item shall be measured and paid as per actual weight or standard weight as per SSR which ever is less. 24 Fixingonly chain link fencing including line wire, any mesh size and any type of standards rails straining bolt etc including provision of binding wire complete all as specified and directed. 25 S & F in repair galvanised 2 strand, steel barbed wire, 2.20mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, includdigng, securing or tying at crossings with and provisiion of galavnised (Zink coating 60 gsm) mild steel wire, staples or steel pins, etc as directed each line wire to measured,complete all as specified and directed. 26 S&F mild steel round bars 10mm dia and over Gde Fe-410 W, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 27 S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,length of bolt 5 to 10 cmlong and dia of neck not exc 15 mm complete all as specified and directed. 28 S&F framed work such as grills, gratings,steel gate , purlin etc., with ends of bars shouldered and/or riv-eted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanksand similar work conforming to Fe 290 gde E-165 complete all as specified and directed. 29 S&F framed work such as portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc.and similar work conforming to Fe 290 gde E-165 complete all as specified and directed. 30 M&L for preparation of new untreated surfaces of steel any description over 10 cms width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed. 31 M&L for applying two coats of cement base paint over a coat of cement primerincluding preparation of new plastered or un-plastered surfaces of wallcomplete all as specified and directed. 32 M&L for 75mm thick PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base in floor etc, finished even and fair complete all as specified and directed. 33 Cleaning of PVC/ Cemented water tank of capacity not exceeding 1000 ltr including disinfecting with chlorine and finally washing with clean water complete all as specified and directed. 34 M&L for chequered cement concrete tiles with chemical resistant coating if size 300x300x 25mm thick, set & jointed in neat cement slurryin floors and pointed with grey cement mixed with pigments, laid over and including 15 mm thick screed bed in CM 1:4, complete all as specified and directed. 35 M&L for sand filing under floor incl spreading and levelling in layers not exc 25 cm thick complete all as specified and directed. 36 M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658-2006 of 60mm thickness M-35 Grade,laid jointed pointed with grey cement and no pigments,complete all as specified and directed by Engr-in-Charge. Note: The sample shall be got approved by GE before bulk procurement & lot shall be got tested independently by the GE. 37 M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658-2006 of 80mm thickness M-40 Grade,laid jointed pointed with grey cement and no pigments,complete all as specified and directed by Engr-in-Charge. Note: The sample shall be got approved by GE before bulk procurement & lot shall be got tested independently by the GE. 38 Cleaning of blockage of Water Closet (Indian or European), trap &pipe line upto first manhole manually by Roding and making it fully functional by flushing with water to entire satisfaction of Enginerr-in-charge including removing the deposited sludge/solid/liquid material, outside MD land and burring in borrow pits including covering with fresh mud, complete all as specified and directed by Engineer-in-charge.Note:-Cost of Taking out sludge, transporting of sludge out side the defence land, earth work & deposition in the pit is deemed to be included in the unit rate to be quoted by tenderer. 39 Opening of cover (of any description and size) of septic tanks and soakage wells/pits, de-sluding / de-watering contaminatedwith fine waste materials ( liquid sludge) alongwith solid waste from septic tank and soakage wells/pits of any capacity/depth by mechanical pumping (Truck mounted mechanical machine) / manually making it fully functional to to entire satisfaction of Engineer-in- charge and and removing & depositing the sludge outside the periphery of defence land at a minimum distance of 50 m from nearby living accn and burring in borrow pits including covering with fresh mud and refixing the cover after cleaning / removing the liquid waste material of septic tanks / soakage wells / pits including cutting holes through slab/ wall where required for inserting pipe and making good the same with cement mortar to match with existing surfaces complete all as specified and directed by Engr-in-Charge.Note:-Cost of Taking out sludge, transporting of sludge out side the defence land, earth work & deposition in the pit is deemed to be included in the unit rate to be quoted by tenderer. 40 M&L for complete servicing and repair of Split type AC 1.5/2 Ton capacity incl taking down of air conditioner, servicing and cleaning of all accessories, oiling of fan motor, checking of wiring connections and re-fixing in the same in position and testing complete all as specified and directed by Engr-in-Charge. Note:- Unsv accessories will be measured and paid seperately under respective items of Sch 41 Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Split AC 2.0 T capacity complete all as specified and directed. 42 Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Split AC 1.5 T capacity complete all as specified and directed. 43 Supply only Fan/blower electric motor single phase 230 V complete for inner unit complete all as specified and directed. 44 Supply only Fan/blower electric motor single phase 230 V complete for outerunit complete all as specified and directed. 45 Supply only Starting capacitor of suitable capacity complete all as specified and directed. 46 Supply only Running capacitor of suitable capacity complete all as specified and directed. 47 Supply only Overload protection of suitable capacity complete all as specified and directed. 48 Supply only Drain pipe for Split unit PVC 20mm dia complete all as specified and directed. 49 Supply only Fan blade of suitable size for outer unit complete all as specified and directed. 50 Supply only Remote control kit complete for Split type AC complete all as specified and directed. 51 Supply only Condencing unit of Split type AC 2 Ton capacity with complete accessories (Outdoor type) complete all as specified and directed. 52 Supply only Condencing unit of Split type AC 1.5 Ton capacity with complete accessories (Outdoor type) complete all as specified and directed. 53 M&L for complete servicing and repair of Window type AC 1.5/2 Ton capacity incl taking down of air conditioner, servicing andcleaning of all accessories, oiling of fan motor, checking of wiring connections etc and re-fixing in the same in position testing complete all as specified and directed by Engr-in-Charge. Note:- Unsv accessories will be measured and paid seperately under respective items of Sch 54 Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Window AC 2.0 T capacity complete all as specified and directed. 55 Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Window AC 1.5 T capacity complete all as specified and directed. 56 Supply only Capacitor of suitable capacity for Window AC 1.5/2 Ton capacity complete all as specified and directed. 57 Supply only Auto cut thermostate of suitable capacity for window AC 1.5/2 Ton complete all as specified and directed. 58 Supply only Overload protection for Window type AC 1.5/2 ton capacity complete all as specified and directed. 59 Supply only Grill for window AC of suitable size/shape /model as required at site complete all as specified and directed. 60 Supply only Fan blade of suitable size for window type AC unit complete all as specified and directed. 61 Supply only Fan/blower electric motor single phase 230 V complete all as specified and directed. 62 M&L for complete servicing and repair of Water Cooler any capacity, servicing and cleaning of all accessories, oiling of fan motor, checking of wiring connections and re-fixing in the same in position testing complete all as specified and directed by Engr-in-Charge. Note:- Unsv accessories will be measured and paid seperately under respective items of Sch 63 Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Water cooler 40/80 Ltrs complete all as specified and directed. 64 Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Water cooler 60/120 Ltrs complete all as specified and directed. 65 Supply only Fan/blower electric motor single phase 230 V complet for water cooler 40/80 or 60/120 Ltrs capacity water cooler complete all as specified and directed. 66 Supply only Running capacitor of suitable capacity complete all as specified and directed. 67 Supply only Starting capacitor of suitable capacity complete all as specified and directed. 68 Supply only Auto cut thermostate switch for water cooler complete all as specified and directed. 69 Supply only Overload protector for water cooler of any capacity complete all as specified and directed. 70 Supply only Fan blade of suitable size complete all as specified and directed. 71 Supply only Push cock/soft closing tap brass chromium plated of size 15 mm complete all as specified and directed. 72 Supply only PVC connection pipe 600 mm long, both end screwedfor water cooler complete all as specified and directed. 73 Supply only ball valve PVC 15mm size for water cooler 40/80 ltr capacity complete all as specified and directed. 74 M&L for complete servicing and repair of refrigerator/deep freezer of any capacity, servicing and cleaning of all accessories, oiling of fan motor, checking of wiring connections, and re-fixing in the same in position testing complete all as specified and directed by Engr-in-Charge.Note:- Unsv accessories will be measured and paid seperately under respective items of Sch 75 Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Refigerator 165 Ltrs capacity complete all as specified and directed. 76 Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Refigerator 286/310 Ltrs capacity complete all as specified and directed. 77 Supply only Auto cut thermostate switch for Refrigerator defrosts type complete all as specified and directed. 78 Supply only Overload protectors for regrigerations upto 310 Ltrs capacity complete all as specified and directed. 79 Supply only Copper strainer filter for reftrigerator complete all as specified and directed. 80 Supply only Relays suitable for refrigerators upto 310 ltr capacity complete all as specified and directed. 81 Supply only Door switch for refrigerator complete all as specified and directed. 82 Supply only Door spring for refrigerator complete all as specified and directed. 83 Supply only Freezer chest door suitable for 286/310 Ltr capacity complete all as specified and directed. 84 Supply only Magnetised door lock rubber strip D type for regrigerator 286/310 Ltr cacpacity complete all as specified and directed. 85 Supply only Evaporator coil assembly 165 ltrs capacity regrigerator with copper pipe complete all as specified and directed. 86 Supply only Evaporator coil assembly 266/310 ltrs capacity regrigerator with copper pipe complete all as specified and directed. 87 Supply only Fan motor for chiller unit as per existing make complete all as specified and directed. 88 Supply and filling gas charging required to the System of suitable type R-34/12/32 /R22 or as per existing at site complete all as specified and directed. 89 Supply and filling gas charging required to the System of suitable type 134a or as per existing at site complete all as specified and directed. 90 S&F in repair base tray of window type AC 1.5/2 Ton capacity unit complete all as specified and directed including the following:-(a) Removing of compressor condenser, wiring kit, from base tray(b) Fixing of new base having all fittings/fixtures to accommodate all accessories made out of MS sheet 1.6mm thick duly painted.(c) Carrying out the nitrogen pressure for 24 hrs (d) Carrying out the vaccuming and gas charging to unit. Note:- Gas will be measured and paid seperately under respective items of Sch 91 S&F in repair base of water cooler of any capacity unit complete all as specified and directed including the following:- (a) Removing of compressor condenser, wiring kit, from base tray(b) Fixing of new base having all fittings/fixtures to accommodate all accessories made out of MS sheet 1.6mm thick duly painted. (c) Carrying out the nitrogen pressure for 24 hrs (d) Carrying out the vaccuming and gas charging to unit. Note:- Gas will be measured and paid seperately under respective items of Sch A 92 S&F in repair Plug & Socket DB, CRCA Sheet steel, powder coated, with metal plug & socket 3 pin with 32 Amps MCB SP complete all as specified and directed. 93 S&F in repair 6-32 Amps MCB SP, 10 kA, C series, complete all as specified and directed. 94 S&F swing motor suitable for split AC of capacity 1.5/2 TR, complete all as specified and directed. 95 Supply and fixing in repair PVC insulated flexible cable 3 core with multistranded copper conductors round shaped sheathed for 1100 volts grade of size 2.50 Sqmm complete all as specified and directed. 96 Supply and fix in repair capillary copper tube for window , split, water cooler, refrigerator complete all as specified and directed. 97 Taking down of split AC 1.5/2 T capacity from existing location to refixing in another location incl both inner and outer units (filling up gas if necessary ) incl connected accessories in complete all as specified and directed by Engr-in-Charge.
Contract Date: Feb 25, 2026 Contract Value : 18.15 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 6
Jammu And Kashmir View Result →
TenderDetail
Loading tenders