View Bid Results For Autosamplers Tenders

We found 99 Bid Results related to autosamplers tenders. You can find Contractor details who won autosamplers tenders along with contract details in Bid awards announcements section.

Filters
Stage
89
7
3
Tender Publishing Platform
62
37
State / UT
23
11
8
8
7
7
7
6
6
5
5
5
5
4
3
2
2
2
1
1
1
1
1
1
Contract Value
11
21
54
13
Publish Date
0
0
0
0
0
Sector
16
31
13
11
9
9
8
4
4
2
2
1
1
1
1
1
1
Ownership
5
61
20
9
8
1
Within keyword
Active filters:
Showing 1–2 of 99 tenders matching your filters
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
4.
Drinking Water Supply and Sanitation #10709044 Price Bid
Purchase Of High-Performance Liquid Chromatography ( Hplc ) For Wazirabad Laboratory , Hplc For Chemical Section Wazirabadwith The Specification Below : • System Should Be Supplied With Pumps, Detectors, Sample Tray, Columns, Valves Etc Required To Run The Complete Protocol Used For The Water Sample. • System Should Be Comprehensive And Flexible • Isocratic System, Binary Gradient System, Quaternary Gradient System Should Be Available. • Should Have An Option Of Detection Capabilities Include Dad, Uv / Vis, Fl, Ri And Elsd. • Stable And Reliable • Advanced Usb Chip And Optoelectronic Isolation Technology Ensuring Stable Communication. • System Should Be Simple And Safe • Powerful Software Makes It Simple To Control, Capture, Manage And Analyse • Real-Time Pressure Display, Maximum And Minimum Pressure Warning Ensure The Security Product Parameters Technical Parameters: High Pressure Constant Flow Pump 2 Set Flow Rate Range: 0.001Ml / Min-10.000Ml / Min, Flow Accuracy: =±0.2% Flow Precision: Rsd=0.06%, Maximum Pressure: 45Mpa Pressure Accuracy: =±3.0% , Pressure Pulsation: =0.1Mpa Uv / Vis Detector Linear: 2.0Au , Wavelength Range: 190-700Nm Wavelength Repeatability: =0.1Nm, Wavelength Accuracy: =±1.0Nm Band Width: 8Nm, Response Time: 0.0S-5S Baseline Noise: =±0.5×10-5Au, Drift: =1.0×10-4Au / H Path Length: 10 Mm ( Analytical Cell ) Data-Processing Workstation Internal And External Standard Calculation Methods Automatically Displays, Prints, Exports And Starts Other Programs After The Completion Of A Pmeasurement. Comply With The Requirements Of The 21 Cfr Part 11 Directive Of The Fda System Kits 1 Set Power Supply Ac110 / 220V±10%, 50 / 60Hz Optional Accessory: Should Be Available With The Supplier And Price Should Be Quoted As Optional For Individual Part- Column Oven, Autosampler, Degasser, Diode Array Detector, Refractive Index Detector, Evaporative Light Scattering Detector, Fluorescence Detector
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
8.
Petroleum and Natural Gas #9829786 AOC
Bids Are Invited For Customized Amc/Cmc For Pre-Owned Products - 1St Year Preventive Maintenance Visit For 930 Compact Ic Autosampler; Compact Ic Autosampler; Annual Maintenance Contract (Amc); Six-Monthly; Yes , Customized Amc/Cmc For Pre-Owned Products - 2Nd Year Preventive Maintenance Visit For 930 Compact Ic Autosampler; Compact Ic Autosampler; Annual Maintenance Contract (Amc); Six-Monthly; Yes , Customized Amc/Cmc For Pre-Owned Products - 3Rd Year Preventive Maintenance Visit For 930 Compact Ic Autosampler; Compact Ic Autosampler; Annual Maintenance Contract (Amc); Six-Monthly; Yes , Customized Amc/Cmc For Pre-Owned Products - 1St Year Preventive Maintenance Visit For 905 Titrando Usb Sampler Processor; 905 Titrando Usb Sampler Processor; Annual Maintenance Contract (Amc); Six-Monthly; Yes , Customized Amc/Cmc For Pre-Owned Products - 2Nd Year Preventive Maintenance Visit For 905 Titrando Usb Sampler Processor; 905 Titrando Usb Sampler Processor; Annual Maintenance Contract (Amc); Six-Monthly; Yes , Customized Amc/Cmc For Pre-Owned Products - 3Rd Year Preventive Maintenance Visit For 905 Titrando Usb Sampler Processor; 905 Titrando Usb Sampler Processor; Annual Maintenance Contract (Amc); Six-Monthly; Yes , Customized Amc/Cmc For Pre-Owned Products - 1St Year Preventive Maintenance Visit For 831 Kf Coulometer; 831 Kf Coulometer; Annual Maintenance Contract (Amc); Six- Monthly; Yes , Customized Amc/Cmc For Pre-Owned Products - 2Nd Year Preventive Maintenance Visit For 831 Kf Coulometer; 831 Kf Coulometer; Annual Maintenance Contract (Amc); Six-Monthly; Yes , Customized Amc/Cmc For Pre-Owned Products - 3Rd Year Preventive Maintenance Visit For 831 Kf Coulometer; 831 Kf Coulometer; Annual Maintenance Contract (Amc); Six-Monthly; Yes , Customized Amc/Cmc For Pre-Owned Products - 1St Year Preventive Maintenance Visit For Buret Calibration; Buret Calibration; Annual Maintenance Contract (Amc); Six-Monthly; Yes , Customized Amc/Cmc For Pre-Owned Products - 2Nd Year Preventive Maintenance Visit For Buret Calibration; Buret Calibration; Annual Maintenance Contract (Amc); Six- Monthly; Yes , Customized Amc/Cmc For Pre-Owned Products - 3Rd Year Preventive Maintenance Visit For Buret Calibration; Buret Calibration; Annual Maintenance Contract (Amc); Six-Monthly; Yes
Contract Date: Ref. Documents Contract Value : 10.01 Lakh
Boards / Undertakings / PSU No of Bidders 1
9.
Science and Technology #9789696 AOC
Bids Are invited for 1 Essential Spares For Analytik Jena Make Aas , 2 Essential Spares For Analytik Jena Make Aas , 3 Essential Spares For Analytik Jena Make Aas - Quartz Cell Without Windows For Aas Hydride Systems Hs 55 And Hs 60 As Per Specification , 4 Essential Spares For Analytik Jena Make Aas - Set Quartz Window Hs For Hydride Cell Unit Contra Series As Per Specification , 5 Essential Spares For Analytik Jena Make Aas , 6 Essential Spares For Analytik Jena Make Aas , 7 Essential Spares For Analytik Jena Make Aas , 8 Essential Spares For Analytik Jena Make Aas , 9 Essential Spares For Analytik Jena Make Aas , 10 Essential Spares For Analytik Jena Make Aas , 11 Essential Spares For Analytik Jena Make Aas , 12 Essential Spares For Analytik Jena Make Aas , 13 Essential Spares For Analytik Jena Make Aas - Z Graphite Tube Pin Platform Pyrolytically Coated Long As Per Specification , 14 Essential Spares For Analytik Jena Make Aas , 15 Essential Spares For Analytik Jena Make Aas , 16 Essential Spares For Analytik Jena Make Aas - Burner Head Ac 100 Mm For Higher Sensitivity In The Acetylene Or Air Flame As Per Specification , 17 Essential Spares For Analytik Jena Make Aas - Burner Head No Ac 50 Mm For Acetylene Or Nitrousoxide Or Acetylene Or Air Flame As Per Specification , 18 Essential Spares For Analytik Jena Make Aas , 19 Essential Spares For Analytik Jena Make Aas , 20 Essential Spares For Analytik Jena Make Aas , 21 Essential Spares For Analytik Jena Make Aas , 22 Essential Spares For Analytik Jena Make Aas , 23 Essential Spares For Analytik Jena Make Aas , 24 Essential Spares For Analytik Jena Make Aas , 25 Essential Spares For Analytik Jena Make Aas - Polystyrene Sample Vials 1 And Half Ml For Autosampler As Per Specification , 26 Essential Spares For Analytik Jena Make Aas Total Quantity : 39
Contract Date: Ref. Documents Contract Value : 25.97 Lakh
Government Departments No of Bidders 1
Contract Date: Ref. Documents Contract Value : 91,800
Government Departments No of Bidders 3
15.
Educational and Research Institute #9417016 Technical Bid
Supply Of Consumables/Non-Consumables For Department Of Pharmacy , Consumables , 2-Methyl-2-Propanol Ar , 2,6-Dimethylaniline Ar , 4-Aminoantipyrine Ar , 4-Dimethylaminobenzaldehyde Ar , Acetic Acid Hplc , Acetic Anhydride Ar , Acetone Hplc Grade , Acetonitrile Hplc Grade , Ammonium Acetate Ar , Ammonium Chloride Ar , Ammonium Hydroxide Ar , Ammonium Phosphate, Dibasic Ar , Anhydrous Ferric Chloride Ar , Anhydrous Glacial Acetic Acid Ar , Boric Acid Ar , Brilliant Green. Solution (Indicator Grade) , Bromothymol Bluesolution (Indicator Grade) , Butylated Hydroxytoluene Ar , Cerric Ammonium Sulphate Ar , Chlorobutanol Ar , Chloroform Ar , Chloroform Hplc , Citric Acid Ar , Citric Acid Monohydrate Ar , Concentrated Nitric Acid Ar , Concentrated Hydrochloric Acid Ar , Concentrated Sulphuric Acid Ar , Crystal Violet (Indicator Grade) , Crystal Viotet Solution (Indicator Grade) , D-10-Camphosulphonic Acid Ar , Diammonium Hydrogen Phosphate Ar , Dichloromethane Ar , Diethylamine Ar , Dimethyl Formamide Ar , Dimethyl Sulphoxide Ar , Dimethylaminobenzaldehyde Reagent Ar , Dioctyl Sodium Sulphosuccinate Hplc , Disodium Hydrogen Phosphate, Anhydrous Ar , Ethanol Ar , Etherhplc , Ethyl Paraben Pharmaceutical Rs , Ferrous Sulphate Ar , Formic Acid Ar , Hexylamine Ar , Inosine Ar , Mercuric Acetate Ar , Methanesulphonic Acid Ar , Methanol Hplc , Methyl Red (Indicator Grade) , Mordant Black Ii Mixture (Indicator Grade) , Orthophosphoric Acid Ar , Perchloric Acidar , Phenol Red Solution(Indicator Grade) , Brij 35 (30% Solution W/V) Non Ionic Surfactant Stable In Acid And Alkaline Solution , Potassium Bicarbonate Ar , Potassium Carbonate Ar , Potassium Chromatear , Potassium Dihydrogen Orthophosphate Ar , Potassium Hydrogen Phthalate Ar , Potassium Phosphate, Dibasic Ar , Quinaldine Redsolution(Indicator Grade) , Silicagel Crystals (For Dessicator) , Sodium 1- Heptane Sulfonate Monohydrate Ar Ion-Pair Chromatography , Sodium 1- Hexane Sulfonate Monohydrate Ar Ion-Pair Chromatography , Sodium 1-Octane Sulfonate Monohydrate Ar Ion-Pair Chromatography , Sodium 1- Pentane Sulfonate Monohydrate Ar Ion-Pair Chromatography , Sodium 1-Decane Sulphonate Ar Ion-Pair Chromatography , Sodium Acetate Dihydrate Ar , Sodium Bicarbonate Ar , Sodium Butane Sulphonate Hplc , Sodium Citrate Ar , Sodium Dihydrogen Orthophosphate Dihydrate Ar , Sodium Dodecyl Sulfate Ar , Sodium Metabisulphite Ar , Sodium Perchloratear , Sodium Perchlorate Hplc Grade , Tertiary Butylmethylether Hplc Grade , Tetrabutyl Ammonium Hydrogen Sulphate Ar , Tetrabutylammonium Hydroxide Ar , Tetradecylammonium Bromide Ar , Tetraheptylammonium Bromide Ar , Tetrahydrofuran Hplc Grade , Tetramethylethyldiamine Ar , Tetrabutylammonium Dihydrogen Phosphate Ar , Tetramethyl Ammonium Hydrogen Sulphate Ar , Thymol Bluesolution (Indicator Grade) , Triethylaminear , Trifluoroacetic Acid Ar , Tris(Hydroxymethyl)Aminomethane Ar , Xanthydrol Ar , Consumables , Stainless Steel Column 15Cm * 4.6Mm, Packed Withoctadecylsilane Bonded To Porous Silica (5?M) , Stainless Steel Column 25Cm * 4.6Mm, Packed Withoctadecylsilane Bonded Porous Silica (5?M) , Stainless Steel Column 15Cm * 4.6 Mm, Packed With Octylsilane Bonded To Porous Silica (5?M) , Stainless Steel Column 25Cm * 4.6 Mm, Packed With Octylsilanebonded To Porous Silica (5?M) , Stainless Steel Column 25Cm * 4.6 Mm, Packed With Nitrile Groups Chemically Bonded To Porous Silica (10?M) , Micropipette Carousel Stand For Brands Including Borosil And Corning Lambda Plus , Radial Tip Test Tube Brush (20Cm) , Radial Tip Test Tube Brush (30Cm) , Babcock Test Bottle Brush (30Cm) , Soap Solution For Glassware Washing , Mobile Phase Reservoir Bottle, Glass, Clear, 2L, Screw Top, Gl45 Threads. Specification:Should Comply With Usp Type 1 Boro 3.3 Glass Should Be With Pp Screw Cap (Gl-45) Should Be Suitable For Storage And Distribution Of Hplc Mobile Phases And Solvents Gl45 Thread For Hplc Transfer Plug High Chemical Resistance No Tilting And No Risk Of Spillage Long-Lasting White Enamel Graduations. Autoclavable At +121 °C Or +134 °C , Glass Volumetric Flask10 Ml Class A , Glass Volumetric Flask25 Ml Class A , Glass Volumetric Flask50 Ml Class A , Glass Volumetric Flask100 Ml Class A , Glass Beaker 2.5 Lclass A , Bulb Pipettes 0.5 Ml Class A , Low Actinic Stained Glass Volumetric Flask 100 Ml. Class A Glass , Low Actinic Stained Glass Volumetric Flask 50 Ml Class A Glass , Low Actinic Stained Glass Volumetric Flask 25 Ml Class A Glass , Low Actinic Stained Glass Volumetric Flask 10 Ml Class A Glass , Graduated Burette, 50 Mlclass A , Quartz Cuvettes For Uv Vis Measurements With Certificate 3.5 Ml , Graduated Pipette, 25 Mlclass A Glass , Screwtop Autosampler Glassvial 1.5 Mlfor Hplc (Pack Of 100) , Polypropylene Conical Tubes With Screwcap For Centrifuge 50 Ml ( 30Mm Diameter) (Pack Of 100) , Micro Spatula (Nickel-Stainless Steel) 15Cm , Polypropylene Conical Tubes With Screwcap For Centrifuge 15 Ml(Pack Of 100) , Glass Microfibrefilter Paper (Whatmangf/C), Diameter 125 Mm, Thickness 205 Micron, Pore Size 20-25 Micrometer (Pack Of 100) , Glass Measuring Cylinderclass A1000 Ml , Nitrile Gloves (Disposable, Latex Free, Powder-Free, Ce Compliant, Box Of 100) Size 6.0 , Nitrile Gloves (Disposable, Latex Free, Powder-Free, Ce Compliant, Box Of 100) Size 6.5 , Nitrile Gloves (Disposable, Latex Free, Powder-Free, Ce Compliant, Box Of 100) Size 7.0 , Rolled Tissue Roll(White Colour) , Laboratory Butter Paper White Colour , Syringe Filter Units, Disposable, Pvdf, Pore Size 0.45?M, Filter Diameter 25Mm (Pack Of 100) , Syringe Filter Units,Disposable, Nylon, Pore Size 0.45?M, Filter Diameter 25Mm (Pack Of 100) , Syringe Pp/Pe Without Needle, Centered Luer Slip Tip, Graduated, 10 Ml (Pack Of 100) , Self-Sealing Cover 10Cm*7Cm (Pack Of 100) , Self-Sealing Cover 25Cm*17Cm (Pack Of 100 , Micropipette Tips-1000?L Clear, Nuclease Free Capacity : 1000?L, (Transparent, Pyrogen Free, Autoclavable) (Pack Of 500) , Porcelein Morter And Pestle 1L , Equipments , Ph Meter Specifications: 1. Ph Range: 0.00 To 20.00 Units 2. Resolution: 0.01 Unit 3. Accuracy: ±0.01 Units 4. Calibration: Minimum 2 Point For Automatic/ 3 Stage Calibration, For Manual With Buffer Solution For Minimum 3 Point Calibration. Automatic Buffer Recognition 5. Electrode Stand: Holds 3 Standard Size Electrodes, Hands Free Simplified Sampling. Plastic Swing Arm And Quick Vertical/Horizontal Adjustment 6. 2-4 Channel For Ph Measurements 7. Electrode + Standard Buffer Solution (Ph 4.0, 7.0, 10.01 X 200Ml For Each Bottle) + Standard Electrode Holder +Ac /Dc Adaptor 8. Should Have Data Storage Facility For 1000-2000Rangeand Record Maximum And Minimum Value 9. Tri-Combination Ph/Atc Electrode 10. Display: Digital Display With 0.001 Ph Unit Readability 11. Should Supply Data Connector Cable 12. Warranty:2 Years , Analytical Weighing Balance Specifications: 1. Automatic Calibration With Built In Weight 2. A Built In Under Hook For Below Weighing System (Optional) 3. Easy To Read Lcd Display With Back Light 4. Density Measurement For Solid And Liquid (Optional) 6. Stainless Steel. Weighing Pan, Level Indicator, Adjustable Fit 7. Full Tare Range Up To Max. Capacity Of The Balance 8. Max Capacity: 200 - 220 G 9. Readability: 1Mg 10. Tare Range: Full 11. Repeatability: 1 Mg 12. Linearity: 2Mg 13. Pan Size- 90Mm Or More 14. Stabilization Time 3-4 Sec 15. Communication-Rs 232 Interfac 16. Power Supply: Ac 220V/50-60Hz 1.7Essential Accesory: Charger , Tabletop Weighing Balance (Precision) Specifications: 1.Electronic Weighing Balance With Square/ Rectangle Platform Design With Maximum Capacity Of 6000G 2. Easy To Read Lcd Display With Back Light 3. Stainless Weighing Pan 4. Tarefacility Should Be Available.5. Readability: 0.1G(100Mg) 6. Repeatability: 0.1G 7. Linearity: 0.2 G 8. Stabilization Time: 3-4 Sec 9. Power Supply: Ac 220V/50-60Hz 10.Essential Accesory: Charger , Wall Mounted Distillation Unit For Laboratory Specifications: 1. Made Of Stainless Steel 2. Capacity Of 6 L Per Hour 3.Heater Source: Immersion Healting Element 4.Power: 220/230 V 50Hz , Plastic Water Can 25 Litre Capacity With Tap For Storage Of Water , Electronic Calculator , Stainless Steel Scissors With Plastic Handle (8 Inches)
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 9
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
19.
Educational and Research Institute #8858714 Technical Bid
Purchase Of Equipment Atomic Absorption Spectrophotometer ( Aas ) : Fully-Integrated Benchtop Double Beam Atomic Absorption Spectrometer ( Aas ) Having The Following Specifications Should Be Quoted: Model Number And Technical Specification As Claimed Must Be In The Website For Verification. Quote Price Must Be In Indian Rupees And Includes Delivery Charges Up To Laboratory Technicalspecification Monochromator Should Have Littrow Or Better Design With Motorized Drive For Automatic Wavelength Selection And Peaking. Mirror Free Fiber Optics Light Transmission For Maximum Light Throughput And Best Detection Limit Preferred, Wavelength Range 190 – 900 Nm Diffraction Grating 1800 Lines / Mm Blazed At 236 Nm And 597 Nm Is Preferred , Reciprocal Linear Dispersion: 1.6 Nm / Mm Or Better , Background Correction Should Have Built-In Continuum Source Double-Beam Background Correction Using High-Intensity Deuterium Arc Lamp.Spectral Bandwidths User Selectable Automatic Slit Widths Of 0.2, 0.7 And 2.0 Nm At Their Optimized Slit Height.Detector Wide-Range Segmented Solid-State Detector, Lamp Turretminimum 8-Lamp Turret With Built-In Power Supplies Slot For Edl / Super Lamp Should Be Quoted.Lamps Requirements1.Single Or Multi Element Cathode Lamp-Fe, Mn, Cu, Zn, Ni, Cr, Cd, Ca, Mg, K, Mo, B, Na, P, Si, Al. 2. Electrode Less Lamp- As. Hg, Pb, Cd, Zn. Gas Controls Should Have Fully Computer-Controlled With Oxidant And Fuel Monitoring. Keyboard-Activated Remote Ignition System With Air-Acetylene. Acetylene Flow Should Be Automatically Adjusted Prior To The Oxidant Change When Switching To Or From Nitrous Oxide-Acetylene Operation.Safety Functions Interlocks To Prevent Ignition In Absence Of Proper Burner Head, The Nebulizer / End Cap, Or The Burner Drain System Preferred. Sample Introduction System Modular Sample Introduction System Consisting Of The Quick-Change Spray Chamber, Burner Head And Nebulizer Units. Alignment Of The Flame In The Light Beam Is Fully Automatic, Using A Motorized Burner Mount For Vertical And Horizontal Burner Adjustment And Automatic Software-Controlled Self-Optimization Of The Burner Position. The Optimization Of The Operating Flame Condition Is Also Fully Automatic And Software Controlled. Nitrous Oxide Burner Head, Hose Assemblymust Be Quoted If Required For Analysis Of Elements Mentioned In Tender Specification. Data Control System Complete Pc Control Using Windows Based Software Operating Under The Microsoft® Windows® 10 With Complete Control Of The Instrument And Its Major Accessories Plus Data Handling And Storage Should Be Quoted. Accessories ( A ) Suitable Exhaust Hood ( B ) Uhp Grade Acetylene Gas Filled Cylinder ( C ) Uhp Grade Argon Gas Filled Cylinder ( D ) Uhp Grade Nitrous Oxide Gas Filled ( E ) Double Stage Gas Regulators For Acetylene, Argon & Nitrous Oxide ( Or Imported If Required ) ( F ) Gas Purification Panel For Above Gases ( G ) 10 Kva Online Ups , On Sitewarranty Three Year , Installation / Demonstration Free Of Cost , Chns Analyser: Fully Automated Pc Controlled Elemental Analyses For Solids, Liquid And Semi-Solid Samples. Operating Modes For Measurement Of Chns, Chn, Cns, And S. Model Number And Technical Specification As Claimed Must Be In The Website For Verification. Quote Price Must Be In Indian Rupees And Includes Delivery Charges Up To Laboratory. Sample Weight Range : Upto 1000 Mg For Chns Mode. It Should Be Able To Handle At Least 10Mg Absolute Carbon In Chns Mode. Detection Range: 0 To 100% For All Elements ( C, H, N, S ) Lod : 50 Ppm Or Better Standard Deviation : ?0.1% Of Absolute. Fully Digital Electronics That Should Be Fully Integrated In Unit, No External Control Panels Required Should Have Mass Flow Controller / Electronic Flow Controller For Constant Flow Of Carrier Gas. Quick Swap Clamp Connections For Fast Maintenance. Standard Deviation : ?0.1% Of Absolute. Fully Digital Electronics That Should Be Fully Integrated In Unit, No External Control Panels Required, Should Have Mass Flow Controller / Electronic Flow Controller For Constant Flow Of Carrier Gas.Quick Swap Clamp Connections For Fast Maintenance.Furnace System• Should Have Two Zone Furnace System, Separate For Combustion And Reduction With Independent Temperature Control For Each Furnace. It Should Be Possible To Set Difference Temperature For Combustion And Reduction In Chns Mode.• Controlled Furnace Temperature Should Be 1200 Deg C Or More • Furnace Working On Low Voltage For Safety And Long Life With 10 Years Warranty. • Should Have Possibility To Use Ceramic / Quartz Ash Finger To Handle High Halogen Or Fluorine Contents Sample. Separation System• Advanced Chromatographic Separation Of Gases Using Temperature Programmed Desorption Technology.• Complete Instrument Control Over Elution Process With Provision Of Auto Zero Of Baseline After Each Element Elution.• Full Separation Of All Analytes And There Should Be No Peak Tailing Or Peak Overlap• Sulphur Being A Crucial Element, Should Be Analysed With Higher Column Temperature ( Separation Column ) Than Nitrogen, Carbon, And Hydrogen. All Necessary Accessories / Options In This Regard Should Be Quoted As Mandatory Items, Detector System• Oxygen Intrusion Free Thermistor Technology Based Temperature Stabilized Tcd Detector For Measurement Of C-H-N-S• 10 Year Or More Warranty On Tcd.• All The Internal Gas Flow Line Should Be Heated To Avoid Condensation. Autosampler System• Electromechanical Auto Sampler System With 100 Positions Or More. The Autosampler Should Hold At Least 500 Mg Of Soil Sample.Pneumatic Autosampler Is Not Acceptable. • The Autosampler Should Be Zero Blank And Ensure Complete Removal Of Atmospheric Gases Before Sample Injection Into The High Temperature Reactor / Furnace. It Is A Crucial Scientific Requirement And Must Be Met.Carrier Gas: Possibility Of Using Argon Gas Or Helium Gas As A Carrier Gas. There Should Be Option For Automatic Carrier Gas Switching From Helium To Nitrogen Or Argon Or There Should Be Option Switch Off The Gas Supply While The Machine Is At Working Temperature To Save Carrier Gas And Time.Software• Should Be Windows 10 / 11 Professional Based And Should Have Display Of Set And Actual Pressures, Flow Rates, Temperatures, Number Of Samples Analysed With Provision For Setting Maintenance Interval With Warning When Maintenance Needed • Should Have Segmented Leak Check Through Software To Enable Identification Of Exact Position Of Leak.Consumables: To Be Supplied With Consumables Sufficient For 1, 000 Sample Analysis In Chns / Cns Mode, Accessories Vendor Should Quote For Complete System Including The Following Items S. No. Details Quantity, 1 Pc ( Intel Core I5 Or Better , Ram-At Least 8Gb Ram, Ssd 512 Gb, Hard Drive-1Tb Or More, Screen Size-21’’Or More, At Least 3 Usb 2.0 Portswindows 10, 64-Bit ) , Black & White Laserjet Printer 012 Uhp Grade Helium Gaswith Double Stage Regulator 013 Uhp Grade Oxygen Gaswith Double Stage Regulator , Necessary Documents:1. Catalogue In Original. 2. All Technical Specifications Should Be Printed On The Manufacturers Catalogue / Data Sheet. Separate Sheet Will Not Be Acceptable.3. Please Include The List Of Minimum 10 Users In India.On-Site Warranty Three Year , Double Beam Uv Vis Spectrophotometer: Microprocessor Based Uv-Vis Spectrophotometer For Operation On 220V / 50Hz. ? Stand-Alone Operation As Well As Complete Control Through Pc With Pc Software Supplied As Standard ? Double Beam Optics With Czerny-Turner Monochromator ? Wide Wavelength Range Of 1, 100 Nm To 190 Nm ? Variable Spectral Bandwidth 0.5, 1, 2, 4, 5 Nm ? Wavelength Setting In 0.05 Nm ? Wavelength Accuracy Of + 0.1Nm For D2 Spectral Line ? Wavelength Repeatability Of + 0.1Nm ? Variable Wavelength Scanning Speed: = 3, 000 Nm / Min ? Slew Rate : 4800 Nm / Min ? Ultra Low Stray Light Of <0.05% At 220Nm Nai, 360Nm Nano2 ? Wide Photometric Range Of -3.0 To +3.0 Abs And 0 To 300 %T ? High Photometric Accuracy Of + 0.002 Abs ( 0~0.5 Abs ) ? High Photometric Repeatability Of Less Than ± 0.001 Abs ( 0~0.5 Abs ) ? Baseline Stability: = 0.0004 Abs / 30 Min ( 500 Nm, One Hour After Light Source Turned On ) ? Baseline Flatness: ± 0.001 Abs ( 1100 ~ 190 Nm, One Hour After Light Source Turned On ) ? Ultra Low Photometric Noise Of < 0.0008 Abs ( 500 Nm ) ? Dual Source – High Intensity Halogen Lamp And Deuterium Lamp With Built-In Light Source Auto Position Adjustment ? High Sensitivity Silicon Photodiode Detector ? 3 Or More Usb Ports For High Speed Pc And Printer Connectivity ? All Operational Modes As Standard – Photometric; Spectrum; Quantitation; Kinetics, Time Scan, Bio-Method In Stand Alone And Pc Mode. ? Large Sample Compartment Compatible With Wide Range Of Accessories. ? Must Supply One Pair Of 10Mm Path Length Quartz Cuvettes Of 3.5 Ml Volume As A Standard Supply ? 12 Months Warranty From The Date Of Installation On Site Warranty : Three Years
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
21.
Educational and Research Institute #8763112 Technical Bid
Tender For Ridf Project - Atomic Absorption Spectrometer :A Bench Top High Sensitive Atomic Absorption Spectrometer For Metal & Metalloids Analysis In Food & Agricultural Matrix Along With Software To Meet Global And Domestic Food Regulations Like Eu / Usfda / Japan / Fssai With Following Specifications.1. Type: Pc Controlled True Double Beam Atomic Absorption Spectrometer N2. Optics: Fully Sealed Narrow Beam Fibre Optics For Maximum Light Transmission For The Best Detection Limits With Least Maintenance.3. Wavelength Range: 190-900 Nm Or Better. N4. Monochromator: Computer Controlled Wavelength Selection With Diffraction Grating Of 1800 Lines / Mm Or More Using High Capability Detector And Focal Length Of 250 Mm Or More. N5. Slit: Automated Slit Selection With Settings Of 0.2 To 1.0 Nm Or Better.6. Detector: Wide Range Photomultiplier Tubes ( Pmt ) Covering Full Wavelength Range Or Solid State Detector, With Highest Quantum Efficiency. N7. Background Corrector: High Intensity / Speed Deuterium Background Corrector Or Better Technology.8. Hollow Cathode Lamps: Single Elements Hollow Cathode Lamp For Analysis For Various Elements Viz., Ag, Au, As, Cd, Cr, Cu, Fe, Hg, Mn, Ni, Pb, Zn. The Lamps Should Have Guaranteed 5000 Ma Hour Of Usage Time Or More. Super Lamps / Edl Lamps Should Also Be Provided For As And Hg.9. Lamps Positions: Minimum 8 Or More. N10. Furnace Atomizer:I. The Graphite Furnace Atomizer Alignment Should Be Fully Automatic.Ii. The Furnace Autosampler Must Be Integrated To Main Spectrometer With A Minimum Of 50 Sample Positions Or More And Should Have Auto-Dilution Capability For Standards And Samples.Iii. System Should Be Equipped With Pyrolytically Coated Graphite Tube For Rapid Furnace Heating Up To 2700 °C Or Better With Facility For Background Correction.Iv. Facility Of Imported Re-Circulating Chiller Of Appropriate Capacity For Cooling The Graphite Furnace. Nv. Matrix Modifier Options In Software And Supply Of Appropriate Modifier Solutions Along With The System Is Desirable. Vi. Variable Gas Flow For Furnace For Minimum Consumption, An External Protective Gas Stream Around The Graphite Tube To Maximize Tube Life.Vii. Accessibility To Run Different Elements Sequentially Without Manual Disturbance.Viii. Furnace Should Have Option Of Injection Temperature For Samples Like Oils And Organics. 11. Nebulizer: Adjustable Nebulizer With Inert Platinum / Iridium Capillary And Venturi For Corrosion Resistance.12. Burner: Air / Acetylene Burner With Corrosion Shield. System Should Come With 10 Cm Standard Titanium Burner Head For More Sensitivity. The System Should Have Software Controlled Automatic Vertical And Horizontal Alignment Of The Flame Burner Head For Optimum Light Transmission.13. Spray Chamber: Fluorinated And Acid Resistant High-Density Polyethylene For Aqueous And Organic Solutions. The Spray Chamber And Nebulizer Should Be Stack Design And Easy To Demount And User Cleanable. N14. Impact Bead: Externally Adjustable Impact Bead With Option For Inert Impact Bead For Samples With Hf.15. Sensitivity: Better Than 0.9 Absorbance With Precision Less Than 0.5% Rsd For 5 Ppm Cu Solution. N16. Hydride Generator: Should Be Continuous Flow / Mercury Hydride System / Flow Injection Type For High Sensitivity And Analysis Of All The Hydride Forming Elements.17. Vapor Generation Accessory: Modular Accessory For Determination Of Hydride Forming Elements Like Hg, As, Etc. Spare Hydride Modules Should Be Available.18. Software: User Friendly Updated Software Must Be Provided For Seamless Control Of The System. N19. Gas Cylinder: High Purity Acetylene, Argon And Other Required Gas Cylinders With Compatible Regulators And Necessary Tubes, Nuts And Ferules.20. Air Compressor: Oil Free Air Compressor21. Vent And Hood Assembly: Should Be Provided With Ducting ( 10 Ft. Or More ) Including Fitting And Fixing.22. Safety System: There Should Be Adequate Safety Features Required For Flame Control, Automatic Internal Gas Connections, Flame Shields And Protection, External Adjustment Of All Burner And Spray Chamber Controls. N23. Computer & Printer: Suitable Branded Pc ( Window Workstation With A 22” Monitor ) With Inbuilt Software & Tested For Fool Proof Operation To Operate The Instrument With Laser Jet Printer.24. Housing, Installation And Demonstration: Nthe Minimum Facility Like Tables, Electrical & Gas Panel Fittings, Dehumidifier Machine For Moisture Removing With Temperature-Humidity Controller [ Capacity: 20 L / Day ( 30?, 80% ) ; Area Coverage: Min. 3500 Cu Ft; Rotary Compressor; Circulating Air Volume-225 M3 / H; Automatic Mode ] Should Be Provided For Housing The System In The Laboratory; The Aas System Should Be Installed In Lab Free Of Cost; Onsite Demonstration & Training Of The System By The Application Specialist To Lab Personal Followed By Issuance Of Training Certificates To The Trainees. 25. Warranty & System Calibration: At Least 2 Years Onsite Warranty With One Year Amc Should Also Be Quoted Along With The Offer. Supplier Must Have Kolkata Based Service Facility With Factory Trained Engineer. System Calibration Should Be Done Once In Every Year With Issue Of Calibration Certificate As Per Iso: 17025 During The Warranty Period.26. Performance Certificate: Quoted Equipment Should Be Latest With Proof Of Installation Report / Performance Certificate From At Least 3 Users Of Reputed Organizations Is To Be Attached Along With Technical Bid.27. Emd: Rs. 30, 000 ( Rupees Thirty Thousand Only ) In The Form Of Bank Draft In Favour Of ‘Bidhan Chandra Krishi Viswavidyalaya’ Payable At Kalyani ( Ifsc: Sbin0001082 ) . Scan Copy Of The Draft Must Be Uploaded As The Supporting Document During Submission Of E-Tender. Without Emd Quotations Will Not Be Considered For Technical Or Financial Comparison. However, Bidders Are Requested Not To Send The Original Draft During Tendering Process. N
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
West Bengal View Result →
23.
Science and Technology #8548133 AOC
Tender for Elemental Analyser For Automatic Determination Of C-H-N-S , Elemental Analyser For Automatic Determination Of C-H-N-S (Chns Analyser) , Fully Automated Pc Controlled Elemental Analyser With Following Specifications For Analysing Solid And Liquid Samples 1 Instrument Sample Weight Range 0.1 To 1000 Mg Or Better. Measuring Range 0.01% To 100% For All Elements. Also Mention The Absolute Measuring Range Of All Elements With Proof Standard Deviation =0.1% Of Absolute Measurement Time =10 Minutes In Chns Mode Controller Must Be Equipped With Electronic Mass Flow Controller And Digital Flow Sensors For Accurate Readout Of Flow Pressure And Flow Sensors All Pressure And Flow Sensors Must Be Electronic For Better Accuracy. There Should Be No Analogue Pressure Gauges. Flow Meters On The Analyser Must Be Computer Controlled. Kit For The Measurement Of Fluorinated Samples. 2. Furnace System Furnace Should Have Two Zone Furnace System, Separate For Combustion And Reduction With Independent Temperature Control For Each Furnace. Temperature Controlled Furnace Temperature Should Be 11000C Or More. Documentary Proof Needs To Be Attached Additional Features Should Have Possibility To Use Ceramic/Quartz Ash Finger To Handle High Inorganic/Halogen Or Fluorine Contents Sample. Warranty 10-Years Free Replacement Warranty On The Furnace 3. Separation System Separation Advanced Chromatographic Separation Of Gases. Full Separation Of All Analytes And There Should Be No Peak Tailing Or Peak Overlap. Sulphur Being A Crucial Element, Should Be Analysed With Higher Column Temperature (Separation Column) Than Nitrogen, Carbon, And Hydrogen. All Necessary Accessories/ Options In This Regard Should Be Quoted As Mandatory Items. 4. Autosampler System Sampler System Electrical Auto Sampler System With 60 Positions Or More. Pneumatic Auto-Sampler Is Not Acceptable. Requirement Zero Blank Sample Injection System 5. Detector System Detector Oxygen Intrusion Free Thermistor Technology-Based T
Contract Date: Jan 05, 2026 Contract Value : 37.78 Lakh
Government Departments No of Bidders 2
Contract Date: Ref. Documents Contract Value : 30.30 Lakh
Boards / Undertakings / PSU No of Bidders 3
Contract Date: Ref. Documents Contract Value : 43.08 Lakh
Local Bodies No of Bidders 3
Contract Date: Ref. Documents Contract Value : 15.99 Lakh
Government Departments No of Bidders 1
Contract Date: Ref. Documents Contract Value : 29.73 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Contract Date: Ref. Documents Contract Value : 6.55 Lakh
Government Departments No of Bidders 1
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 9.97 Lakh
Government Departments No of Bidders 1
Contract Date: Ref. Documents Contract Value : 33.27 Lakh
Government Departments No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 11.22 Lakh
Boards / Undertakings / PSU No of Bidders 1
Andhra Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 40.71 Lakh
Local Bodies No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 39.82 Lakh
Local Bodies No of Bidders 3
41.
Educational and Research Institute #6718872 AOC
Equipment , Total Organic Carbon(Toc) Analyser , Flow Injection Toc (With Tnb) Analyzer: Measurement Parameters: Direct Determination Of Tc, Tic, Toc, Npoc, Npoc Plus, Toc In Liquids And Solids And Tnb With Software For Control And Evaluation And Total Nitrogen Estimation By Maintenance Free Chemodetector (Chd)(For Detecting 50 Ppb Or Above); Digestion Mode: Catalytic High Temperature Combustion Of Up To 950°Cor Better;Measurement Range: 0-30,000 Mg/L Or Better; Detection Limit: 4 ?G/L C Or Better; Reproducibility : Cv 1–2%; Measurement Time: Approximately 3-5 Min For Each Parameter; Sample Injection: Automatic Flow Injection With Intelligent Rinsing; Injection Volume: 100–1,000?L Variable Or Better; Particle Handling : 0.7 ?M Or Better; With Automatic Leak Check: Automatic Or Manual Data Export In Different Formats (Lims, Csv, Pdf);Ambient Operating Temperature: 10 °C - 35 °C; Humidity: 5 - 90; Multi-Point Calibration From A Single Standard;Up To 3 Calibration Ranges Each Parameter And Method Can Be Usedwithtoc-Blank Determination And Automatic Result Correction; Self-Check-System-Automatic Monitoring Of Maintenance Intervals, Gas Flows And Pressures, Temperatures And Detector Status;Solids Combustion Module For Solid Samples For Tc/Toc Analysis: High Temperature Combustion Furnace For The Analysis Of Carbon (Tc/Toc) In Solid Samples; Furnace Temperature:1300 Deg C Or Better; Autosampler: Autosampler For Up To 20 Samples Or Better With Sample Vials Of 50 Ml Capacity; Sample Homogenization By Integrated Magnetic Stirrer; Installation Start-Up Package: Final Inspection + Quality Certificate, User Manual Including Trouble Shooting; Consumable Start-Up Kit; Combustion Tube, Catalyst For One Filling; Quartz Wool, Quartz Chips,Required Mats Etc; Required Essential Accessories: A Suitable Pc With Minimum I5 Configuration Or Better; Gas Cylinder – 2 Numbers Of Oxygen Cylinder (99.5% Purity); Suitable Brassregulators; Consumables For 2 Years Of Operation For Both Liquid And Solid Samples For Toc And Tnb Estimation; Required Ups For The Entire Pc Unit. Warranty: 2 Year Warranty For The Full System; Minimum 5-Year Warranty Or Better For Ndir Detector And Furnace Unit From The Date Of Installation, Should Be Provided Only By Oem (Original Equipment Manufacturer). The Quoted Price Should Include All The Above Things As Per The Technical Specification Given And The Same Should Be Supplied To Our Lab In Bharathiar University, Coimbatore, Tamilnadu.
Contract Date: Jan 27, 2025 Contract Value : 23.72 Lakh
Boards / Undertakings / PSU No of Bidders 2
Contract Date: Ref. Documents Contract Value : 1.72 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 1
Maharashtra View Result →
44.
Health and Family Welfare #6644755 AOC
Bids Are Invited For Himachal Pradesh Stirrer , Eye Wash And Shower , Glass Ware Washer , Lod Oven 100 Ltr Hot Air Oven , Analytical Balance Capable To Determine Minimum Sample Weighing 10 Mg Or Less As Per Usp And Maximum Weighing Capacity 500 G Or More And 4 Number Of Analytical Balance. , Semi-Micro Balance Range 0.01 Mg To 220 G As Per Usp Minimum Sample Weighing 20 Mg Or Less , Gc-Hs With Fid Detector And Tcd Detector , Hplc Gradient With Uv Detector Autosampler And Essential Columns , Hplc Gradient With Pda Detector Autosampler And Essential Columns , Hplc Gradient With Uv Detector And Ri Detector Autosampler And Essential Columns , Hplc Gradient With Uv Detector And Fluorescence Detector Autosampler And Essential Columns , Dissolution Apparatus With Auto Sampler , Disintegration Test Equipment With Printer , Disintegration Test Equipment For Bolus With Printer , Dissolution Apparatus- Manual , Toc Analyzer , Microwave Digestion System , Ph Meter , Magnetic Stirrer With Hot Plate , Sonicator With Cooling 30 Ltr , Sonicator With Cooling 20 Ltr , 3 Place Manifold Filtration With Vacuum Pump , Media Preparation And De-Aeration System For Dissolution Apparatus , Gcms With Autosampler And Hs And Ecd Detector , Tablet Hardness Tester , Rotational Viscometer , Icpms , Particle Size Analyzer , Analytical Balance Capable To Determine Minimum Sample Weighing 10 Mg Or Less As Per Uspand Maximum Weighing Capacity 500 G Or More And 4 Number Of Analytical Balance. , Semi-Micro Balance , Range 0.01 Mg To 220 G As Per Usp Minimum Sample Weighing 20 Mg Or Less , Micro Balance Etermine Minimum Sample Weighing 0.8 Mg Or Less As Per Usp And Maximum Weighing Capacity 6.0 G Or More And One Number Of Microbalance. 2 59Procurement Of Lab Equipment For Pharma Testing Lab Total Quantity : 122
Contract Date: Ref. Documents Contract Value : 25.94 Crore
Government Departments No of Bidders 7
Contract Date: Ref. Documents Contract Value : 44.41 Lakh
Local Bodies No of Bidders 2
TenderDetail
Loading tenders